1. Birefringent:
ZEMAX will trace the ordinary ray if the mode is set to 0 or 2. If the mode is set to
1 or 3, the extraordinary ray will be traced. ZEMAX cannot trace both rays at once,
however it is easy to create a multi-configuration lens with the mode set to 0 in configuration 1, and to 1 in configuration 2; this allows inspection of both possible paths as well as simultaneous optimization and layouts of the traced rays.
2. Surface type: P226
3. Coordinate Break:P239
If the "order" flag is set to zero, ZEMAX first decenters in x, and then in y.
Then ZEMAX tilts about the local z axis, then the local y axis, then the
local x axis.
4. Chapter 14 OPTIMIZATION:P385
5. MULTI-CONFIGURATION OPERANDS
GLSS :Surface # Glass.
MOFF : Ignored An unused operand, may be used for entering comments
PAR1: Surface # Parameter 1. Obsolete, use PRAM instead.
PRAM: Surface, Parameter Parameter value(This operand controls any of the parameters)
THIC: Surface # Thickness of surface.
6. Chapter 14 : Optimization, P385
ZEMAX uses an actively damped least squares method
7. heih