锦浪33K-逆变器参数表

合集下载

逆变器20-25-30-36kW中文用户手册

逆变器20-25-30-36kW中文用户手册
7.1.1 LED 灯故障处理...............................................................77 7.1.2 LCD 显示故障处理...........................................................77 7.2 产品维护...................................................................................82 7.2.1 电气连接检查 ..................................................................82 7.2.2 进出风口清洁 ..................................................................82 7.2.3 更换风扇 ......................................................................... 82 7.2.4 更换主机 ..........................................................................84 7.3 逆变器拆除 ............................................................................... 86 第八章 技术数据........................................................................................88 第九章 质量保证........................................................................................92 9.1 质保期 ....................................................................................... 92 9.2 责任豁免 ................................................................................... 92 9.3 质量条款(保修条款) .............................................................. 92 第十章 回收报废........................................................................................93 附录 I:机器选型说明 ..................................................................................94 附录 II:有毒有害物质或元素名称及其含量表 .............................................96

SG330KTL光伏并网逆变器中文使用手册(说明书)

SG330KTL光伏并网逆变器中文使用手册(说明书)
7.2.1 安全说明 ................................................................................................ 35 7.2.2 机械尺寸 ................................................................................................ 35 7.2.3 环境需求 ................................................................................................ 35 7.3 电气连接 ............................................................................................................ 37 7.3.1 输入输出要求 ........................................................................................ 37 7.3.2 线缆要求 ................................................................................................ 38 7.3.3 打开前门 ................................................................................................ 39 7.3.4 直流侧接线 ............................................................................................ 40 7.3.5 交流侧接线 ............................................................................................ 41 7.3.6 接地连线 ................................................................................................ 42 7.3.7 通讯连线 ................................................................................................ 43 7.4 启动与关闭 ........................................................................................................ 44 8 技术数据 ............................................................................................................. 45 8.1 电气部分 ............................................................................................................ 45 8.2 机械部分 ............................................................................................................ 46 8.3 特色数据 ............................................................................................................ 46 8.4 故障对照表 ........................................................................................................ 47 9. 附录 ..................................................................................................................... 48 9.1 质量保证 ........................................................................................................... 48 9.2 联系我们 ......................................................................................................... 49

阳光逆变器型号参数大全

阳光逆变器型号参数大全

参数容量(kW)3型号SG3KTL-M最大输入功率3200W(3200W/3200W)最大输入电压550V启动电压(最小输入电压?)150V额定输入电压370VMPP电压范围(最大功率点电压范围)125~550V满载MPP电压范围160~500VMPPT数量(最大功率追踪)2(两个逆变器集成一体?)每路MPPT最大输入组串数1/1(?)最大输入电流20A(10A/10A)输入端子最大允许电流10A输出额定输出功率3000W最大输出功率(PF=1)3150W最大输出视在功率3150VA最大输出电流15A额定电网电压230Vac (单相)电网电压范围180~276Vac(符合相应国家电网指令要求)额定电网频率50Hz/60Hz电网频率范围45~55Hz/55~65Hz (符合相应国家电网指令要求)总电流波形畸变率< 3 % (额定功率)直流分量<0.5 %In功率因数范围>0.99@满功率, (可调范围0.8超前~0.8滞后)保护孤岛保护具备低电压穿越不具备直流反接保护具备交流短路保护具备漏电流保护具备直流开关选配直流保险丝不具备过压保护压敏保护系统最大效率0.974欧洲效率0.965隔离方式无变压器防护等级IP65夜间自耗电<1W工作温度范围-25~60℃(>45℃降额)相对湿度0~100% 无冷凝冷却方式自然风冷最高海拔4000m (>2000m降额)显示动态图形液晶通讯RS485(RJ45 端子),WiFi(可选)4510 SG4KTL-M SG5KTL-M SG10KTL4300W(3000W/3500W)5400W(3000W/3500W)10800W(5400W/5400W)550V550V1000V150V150V270V370V370V650V125~550V125~550V250~950V170~500V200~500V250~800V2221/2’1/2/3/326A(10A/16A)26A(10A/16A)40A(20A/20A)10A 10A 10A4000W4600W10000W4200W5100W4200VA5100VA11100VA20A22A17A230Vac (单相)230Vac (单相)3/N/PE, 230/400Vac180~276Vac(符合相应国家电网指令要求)180~276Vac(符合相应国家电网指令要求)310~480Vac(符合相应国家电网指令要求)50Hz/60Hz50Hz/60Hz50Hz45~55Hz/55~65Hz (符合相应国家电网指令要求)45~55Hz/55~65Hz (符合相应国家电网指令要求)45~55Hz(符合相应国家电网指令要求)< 3 % (额定功率)< 3 % (额定功率)< 3 % (额定功率)<0.5 %In<0.5 %In<0.5 %In>0.99@满功率, (可调范围0.8超前~0.8滞后)>0.99@满功率, (可调范围0.8超前~0.8滞后)>0.99@额定功率, (可调范围0.9超前~0.9滞后)具备具备不具备不具备具备具备具备具备具备具备选配选配不具备不具备压敏电阻压敏电阻0.9760.9760.980.970.970.972无变压器无变压器无变压器IP65IP65IP65(风扇IP54)<1W<1W<1W-25~60℃(>45℃降额)-25~60℃(>45℃降额)-25~60℃0~100% 无冷凝0~100% 无冷凝0~95% 无凝露自然风冷自然风冷智能强制风冷4000m (>2000m降额) 4000m (>2000m降额) 4000m(>2000m降额)动态图形液晶动态图形液晶动态图形液晶RS485(RJ45 端子),WiFi(可选)RS485(RJ45 端子),WiFi(可选)RS485(RJ45 端子)PV电池板短路电流(DC1/DC2)50A(25A/25A)12152024 SG12KTL SG15KTL SG20KTL SG24MX12800W15800W (7900W/7900W)21000W (10500W /10500W)26800W(13400W/13400W)1000V1000V1000V1000V270V270V300V300V650V650V650V470V250~950V250~950V280~950V280~950V330~800V380~800V480~800V375~850V2222 /3/3/3/3/3/3440A(20A/20A)40A(20A/20A)42A(21A/21A)66A(33A/33A)10A10A10A12A12000W15000W20000W24000W16700W22200W26000W13300VA16700VA22200VA26000VA21A25A33A48A3/N/PE, 230/400Vac3/N/PE, 230/400Vac3/N/PE, 230/400Vac3/PE, 181/315Vac310~480Vac(符合相应国家电网指令要求)310~480Vac(符合相应国家电网指令要求)310~480Vac(符合相应国家电网指令要求)283~400Vac50Hz50Hz50Hz50Hz/60Hz(符合相应国家电网指令要求)45~55Hz(符合相应国家电网指令要求)45~55Hz(符合相应国家电网指令要求)47~53Hz 57~ 63Hz< 3 % (额定功率)< 3 % (额定功率)< 3 % (额定功率)< 3 % (额定功率)<0.5 %In<0.5 %In<0.5 %In<0.5 %In>0.99@额定功率, (可调范围0.9超前~0.9滞后)>0.99@额定功率, (可调范围0.9超前~0.9滞后)>0.99@额定功率, (可调范围0.9超前~0.9滞后)>0.99@满功率, (可调范围0.8超前~0.8滞后)具备具备具备具备具备具备具备具备具备具备具备具备具备具备具备集成集成具备无无具备压敏电阻压敏电阻2级防雷器(40KA)0.980.980.980.9830.9720.9730.9730.98无变压器无变压器无变压器无变压器IP65(风扇IP54)IP65(风扇IP54)IP65(风扇IP54)IP65(风扇IP55)<1W<1W<1W<1W-25~60℃-25~60℃-25~60℃-25~60℃组串型光伏逆变器0~95% 无凝露0~95% 无凝露0~95% 无凝露0~100% 无冷凝智能强制风冷ing智能强制风冷智能强制风冷智能强制风冷4000m(>2000m降额)4000m(>2000m降额)4000m(>2000m降额)4000m (>3000m降额)动态图形液晶动态图形液晶动态图形液晶动态图形液晶RS485(RJ45 端子)RS485(RJ45 端子)RS485(RJ45 端子)RS485(RJ45 端子)PV电池板短路电流(DC1/DC2)PV电池板短路电流(DC1/DC2)PV电池板短路电流(DC1/DC2)PV电池板短路电流(DC1/DC2)50A(25A/25A)50A(25A/25A)50A(25A/25A)50A(25A/25A)3040505060SG30KTL-MSG40KTLSG50MX SG50KTL SG60KTL32kW(16kW/16kW)40500W 51000W 56200W 67500W 1000V 1000V 1000V 1000V 1000V 300V 300V 500V 300V 620V620V 710V 470V 580V280~950V 280~950V 450~950V 300~950V 570~950V 480~800V560~800V450~850V 500~850V 570~850V 22141441231266A (33A/33A )66A(33A/33A)115A 104A(26A/26A/26A/26A)120A 12A12A 12A12A 12A30kW 36000W 50000W 50000W 60000W 30kW 39800W 50000W 55000W 66000W 33.12KVA 39800VA 50000VA 55000VA 66000VA 48A48A 93A80A 96A 3/N/PE,230/400Vac 3/N/PE,277/480Vac 或3/PE, 480Vac 3/PE, 181/315Vac 3/N/PE,230/400Va c3/N/PE,230/400Va c310~480Vac 422~528Vac 283~400Vac 310~480V ac310~480V ac50Hz/60Hz50Hz/60Hz50Hz/60Hz50Hz/60Hz 50Hz/60Hz 45~55Hz/57Hz~63Hz47~53Hz/57~ 63Hz 47~53Hz 57~ 63Hz47~53Hz 57~ 63Hz 47~53Hz 57~ 63Hz < 3 % (额定功率)< 3 % (额定功率)< 3 % (额定功率)< 3 % (额定功率)< 3 % (额定功率)<0.5 %In<0.5 %In<0.5 %In<0.5 %In <0.5 %In >0.99@满功率, (可调范围0.8超前~0.8滞后)>0.99@满功率, (可调范围0.8超前~0.8滞后)>0.99@满功率, (可调范围0.8超前~0.8滞后)>0.99@满功率, (可调范围0.8超前~0.8滞后)>0.99@满功率, (可调范围0.8超前~0.8滞后)具备具备具备具备具备具备具备具备具备具备具备具备具备具备具备具备具备具备具备具备具备具备具备具备具备具备具备具备具备具备具备具备具备具备具备2级防雷器(40KA)2级防雷器2级防雷器(40KA )2级防雷器(40KA )2级防雷器(40KA )0.9830.9830.990.9890.990.980.980.9870.9850.987无变压器无变压器无变压器无变压器无变压器IP65(风扇IP55)IP65(风扇IP55)IP65(风扇IP55)IP65(风扇IP55)IP65(风扇IP55)<1W <1W <1W <1W<1W-25~60℃-25~60℃-25~60℃-25~60℃ -25~60℃0~95% 无凝露0~100% 无冷凝0~100% 无冷凝(中文)0~100% 无冷凝0~100% 无冷凝智能强制风冷智能强制风冷智能强制风冷智能强制风冷智能强制风冷4000m (>3000m降额)4000m (>3000m降额)4000m (>3000m降额)4000m (>3000m降额)4000m (>3000m降额)动态图形液晶动态图形液晶动态图形液晶动态图形液晶动态图形液晶RS485 (RJ45)RS485(RJ45 端子)RS485(RJ45 端子)RS485(RJ45 端子)RS485(RJ45 端子)。

工频GP33系列使用说明书10-120K

工频GP33系列使用说明书10-120K
9. 单机电气规格...........................................................................................................................43
10. 并机安装指导................................................................................................. 45 10.1 概述.................................................................................................................................. 45 10.2 并机安装.......................................................................................................................... 45 10.3 并机设置及 LCD 显示..................................................................................................... 49 10.4 并机规格.......................................................................................................................... 49 10.5 并机故障诊断及处理...................................................................................................... 50

3000W纯正弦波逆变器设计报告

3000W纯正弦波逆变器设计报告

3000W纯正弦波逆变器一、机器基本参数标称功率3000W持续功率;2800W峰值功率6000W2S;整机效率:87%以上300次开机短路,200次短路开机过载保护3200W3S短路立即保护欠压保护20V延时5S关断,过压30V保护立即关断过热保护:65度二、此款逆变器的基本情况(架构,组成)总括的说,这是一款24V逆变器,这款逆变器由三个部分组成,1、前级驱动板;2、后级驱动板;3、功率主板。

1、前级驱动板上主要是由三个小部分组成,一个辅助电源部分,一个部分是PWM驱动,第三个部分是保护部分;2、后级驱动板主要由三个部分组成,一个是SPWM信号的产生(单片机完成)部分,一个是硬件RC死区时间设置部分;再一个就是IR2110的驱动部分。

3、功率主板主要由四个部分组成,一个是前级升压及整流滤波,第二个是后级H全桥正弦变换部分,第三个是稳压反馈部分;第四个是LC滤波部分三、电路结构及原理分析1、前级驱动板A、辅助电源电路的功能就是将功24V的电池电压降到13-15V左右然后再经过LM7812稳成12V后供给整机电路的控制部分供电,先上图:在这个电路中,BT输入电压范围可以达到15-36V,而输出稳定在12V.Q1也可以用P型的MOS管,适当的选取不同型号的P管可以将电压做到60V左右。

下面来讲一下这个电路的工作原理,电路起动的瞬间,电源通过R21提供Q1足够大的基极电流,Q1饱和导通,其集电极电流一部分通过L1给C121充电供给负载,一部分储存在L1里。

当C21两端的电压超过15V时Q4导通,Q3也导通导致Q1的基极电位上升,电流减小,C12的上端的电位下降,由于C12两端的电压不能突变,Q3基极的电位继续迅速下降,Q1的基极电位迅速上升直到快速关断,Q1关断后L1的储能通过续流二极管D7释放给C15和负载,然后开始下一个周期的循环。

B、PWM驱动部分先上图,再做解析这是一个SG3525和专业MOS驱动TC4452组成的强驱动能力驱动电路,TC4452的驱动能力和反应时间都相当的惊人,内部集成了MOS图腾,驱动能力达到了13A。

3KW光伏并网逆变器规格书V1.0

3KW光伏并网逆变器规格书V1.0

3KW光伏并网逆变器产品规格书项目名称:3KW光伏并网逆变器项目编码:拟制:Date审核:Date批准:Date目录关键词:..................................................错误!未定义书签。

摘要:....................................................错误!未定义书签。

1 ................................................................ 概述错误!未定义书签。

............................................................. 产品描述错误!未定义书签。

............................................................. 编制依据错误!未定义书签。

2 ...................................................... 产品名称和型号错误!未定义书签。

......................................................... 产品命名规则错误!未定义书签。

............................................................. 产品附件错误!未定义书签。

系统配置 ........................................... 错误!未定义书签。

............................................................... 选配件错误!未定义书签。

3 ............................................................ 环境要求错误!未定义书签。

5KW并网逆变器参数

5KW并网逆变器参数
自动投运条件
直流输入及电网满足要求,逆变器自动运行
保护功能
直流、交流过压及欠压保护,交流过、欠频保护,过载保护,短路保护,漏电保护,过热保护,防孤岛保护等
通讯接口
RS485/RS232/GPRS/以太网
电气绝缘性能
直流输入对地
1250VAC,1分钟
直流与交流之间
1250VAC,1分钟
使用环境温度
-20℃~+40℃
尺寸(宽×深×高)
466×195×393mm
重量
20kg
二、
型 号
BNSG-5KD
隔离变压器
工频隔离变压器
额定容量
5KW
最大直流输入功率
6KWp
最大直流输入电压
780Vdc
最大输入路数
4组
最大功率点跟踪(MPPT)范围
300Vdc~700Vdc
最大输入电流
17A
输出额定交流功率
5KW
最大交流输出功率
通讯接口
RS485/RS232/GPRS/以太网
电气绝缘性能
直流输入对地
1250VAC,1分钟
直流与交流之间
1250VAC,1分钟
使用环境温度
-20℃~+40℃
使用环境湿度
0~95%,不结露
允许最高海拔
6000米(超过2000米需降额使用)
冷却方式
强制风冷
噪音
≤60dB
防护等级
IP20
显示方式
液晶显示屏
额定输入时输出功率因数
>0.99
最大效率
97%
欧洲效率
96%
允许电网电压范围
190VAC~250AC
额定电网电压

33KW组串逆变器参数

33KW组串逆变器参数

散热方式 环境防护等级 相对湿度 特征 直流输入连接器 交流输出连接器 显示 通讯接口:RS232/RS485/ 射频/以太网/Wi-Fi
智能风冷 电气部分 IP65(风扇 IP55) 0...100%,无冷凝
H4/MC4(opt) 端子台 LCD 支持/支持/ 可选/可选/可选
250V 180V-1000V 600V 460V-800V 38A/38A 12A 2/3
33kW 33kVA 50A 230V/400V 3W+N+PE
输出频率 功率因数 THDI 输出数据(交流) 最大效率 欧洲加权效率 MPPT 效率 设备防护 直流反接保护 输入直流开关 输出过流保护 交流浪涌保护 绝缘阻抗检测 常规数据 尺寸(宽/高/厚) 工作温度
噪音指数 海拔高度 夜间自损耗 拓扑结构
ห้องสมุดไป่ตู้
50/60Hz 0.9leading-0.9laging <3%
98.2% 97.8% 99.5%
支持 支持 yes 类型 III 支持
551/740/276mm –25 °C ... +60 °C 45 度以上降额 ≤55dB(A) 2000m(6560ft)以下不降额 <0.5W 无变压器
33kW 光伏逆变器参数
输入数据 参数 最大输入功率 最高输入电压 启动电压 光伏电压范围 额定电压 满载输入电压范围 最大输入电流 最大组串输入电流 MPP 追踪器数量/ 各追踪器最大并联组串数 输出数据 额定输出功率 最大输出视在功率 输出电流 额定输出电压
逆变器参数
数据 36300W 1000V

单相3-6kw光伏逆变器用户手册

单相3-6kw光伏逆变器用户手册

标题:深度解读单相3-6kw光伏逆变器用户手册在光伏逆变器用户手册中,有关单相3-6kw光伏逆变器的详细操作说明及相关内容,是我们在使用这一设备时不可或缺的重要信息。

在本文中,我们将深度解读这一用户手册,探讨光伏逆变器的工作原理、操作方法、维护保养以及一些实用技巧,帮助您更全面、深入地了解这一设备。

一、光伏逆变器工作原理在用户手册中,首先介绍了光伏逆变器的工作原理。

光伏逆变器利用光能转化为直流电能,经过逆变器的处理,再转化为交流电能,供电给家用电器或并网输出。

在此部分中,用户手册详细讲解了光伏逆变器的组成结构、工作原理以及相关的电气知识,为用户提供了充分的知识储备。

二、操作方法在用户手册的操作方法部分,详细介绍了光伏逆变器的开机、关机、参数设置、故障排除等操作步骤,包括了文字说明和配图演示,方便用户快速上手。

用户手册还特别关注了安全用电知识和操作注意事项,提醒用户在使用逆变器时要注意电气安全,避免发生意外。

三、维护保养光伏逆变器的维护保养是确保设备长期稳定运行的重要环节。

用户手册中对于逆变器的日常维护、安全检查和定期保养等内容进行了详细的介绍,帮助用户了解如何保养设备,延长其使用寿命,减少故障发生的可能性。

四、实用技巧在用户手册的还介绍了一些光伏逆变器的实用技巧,例如如何根据天气条件调整逆变器的工作模式,如何进行数据监测和故障诊断等。

这些实用技巧的介绍,能够帮助用户更加灵活地使用光伏逆变器,发挥其最大功效。

个人观点与总结通过阅读光伏逆变器的用户手册,我对这一设备的工作原理、操作方法、维护保养和实用技巧有了更加深入的了解。

在实际使用中,我发现用户手册中所述的操作方法和维护保养确实能够帮助我更好地管理和使用光伏逆变器,确保其稳定运行。

用户手册中还融入了一些实用技巧,使我能够更加灵活地应对不同的情况,提高了设备的利用率和效益。

光伏逆变器的用户手册不仅在理论知识的传达上做得非常详尽,而且在实用技巧的介绍上也非常贴心。

光伏逆变器的主要技术参数

光伏逆变器的主要技术参数

光伏逆变器的主要技术参数在光伏系统中,光伏逆变器的技术指标及参数主要受蓄电池及负载的影响,其主要技术参数如下。

1.额定输出电压光伏逆变器在规定的输入直流电压允许的波动范围内,应能输出额定的电压值,一般在额定输出电压为单相220v和三相380v时,电压波动偏差有以下规定。

(1)在稳定状态运行时,一般要求电压波动偏差不超过额定值的±5%。

(2)在负载突变时,电压偏差不超过额定值的±10%。

(3)在正常工作条件下,逆变器输出的三相电压不平衡度不应超过8%。

(4)三相输出的电压波形(正弦波)失真度一般要求不超过5%,单相输出不超过10%。

(5)逆变器输出交流电压的频率在正常工作条件下其偏差应在1%以内。

国家标准gb/t 19064-2003规定的输出电压频率应在49~51hz之间。

2.负载功率因数负载功率因数的大小表示了逆变器带感性负载或容性负载的能力,在正弦波条件下负载功率因数为0.7~0.9,额定值为0.9。

在负载功率一定的情况下,如果逆变器的功率因数较低,则所需逆变器的容量就要增大,导致成本增加,同时光伏系统交流回路的视在功率增大,回路电流增大,损耗必然增加,系统效率也会降低。

3.额定输出电流和额定输出容量额定输出电流是指在规定的负载功率因数范围内逆变器的额定输出电流,单位是a;额定输出容量是指当输出功率因数为1(即纯电阻性负载)时,逆变器额定输出电压和额定输出电流的乘积,单位是kva或kw。

4.额定输出效率额定输出效率是指在规定的工作条件下,输出功率与输入功率之比,以百分数表示。

一般情况下,光伏逆变器的标称效率是指纯电阻性负载、80%负载情况下的效率。

逆变器的效率会随着负载的大小而改变,当负载率低于20%和高于80%时,效率要低一些。

标准规定逆变器的输出功率在大于等于额定功率的75%时,效率应大于等于80%。

目前,主流逆变器的标称效率在80%~95%之间,对于小功率逆变器要求其效率不低于85%。

锦浪三相五代组串式光伏逆变器操作说明书

锦浪三相五代组串式光伏逆变器操作说明书

锦浪科技股份有限公司锦浪科技股份有限公司地址: 浙江省宁波市象山县滨海工业园金开路188号,315712 服务热线: 400-101-6600 销售热线: +86 (0)574 6580 3887 传真: +86 (0)574 6578 1606邮箱:****************公司网站: 当您发生问题时,请将您使用逆变器的产品序列号告知我们。

我们将尽快给您答复!使用说明书Ver 1.0锦浪三相五代组串式光伏逆变器注意:如果说明书与实物有出入,请以实物为准。

G5-GR3P(13-30)K246666688122121214235102222223. 操作界面3.1 操作界面示意3.2 状态指示灯3.3 按键3.4 LCD显示屏5. 产品安装5.1 选择安装位置5.2 逆变器安装5.3 电气连接6. 启动及关闭6.1 启动程序6.2 关机程序1. 介绍2.1 安全标识2.2一般性安全指南2. 安全指令1.1 产品描述1.2 包装清单2.3 使用须知7. 一般操作7.1 主菜单7.2 信息目录………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………4………………………………………………………………………………………………………………247.3 设置……………………………………………………………………………………………………………………………………257.4 高级信息……………………………………………………………………………………………………………………………283132337.5 高级设置8. 维修保养9. 故障处置10. 逆变器的处置…………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………7774. 产品搬运及储存4.1 产品的搬运4.2 产品的储存…………………………………………………………………………………………………………3411. 产品规格……………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………图1.1 逆变器正视图1.1 产品描述1.2 包装清单逆变器包装清单包括如下配件,请收到逆变器时检查配件是否齐全:逆变器 x1背挂板 x1不恰当的使用可能会导致触电或烧伤的危险。

Solaredge SE25K SE30K SE33.3K 三相逆变器说明书

Solaredge SE25K SE30K SE33.3K 三相逆变器说明书

INVERSORESInversor trifásicoSE25K / SE30K / SE33.3KDiseñado para trabajar con optimizadores de potenciaInversor a tensión fija CC para una eficiencia superior (98,3%) y strings más largosMonitorización a nivel de módulo concomunicación por Ethernet, inalámbrica o telefonía móvil para una visibilidad completa del sistema Funciones de seguridad avanzadas: protección integrada contra fallos de arco y apagado de seguridad SafeDCIP65 - Instalación en interiores y exterioresUnidad de seguridad de CC integrada opcional: elimina la necesidad de interruptores externos de CC Puesta en marcha rápida y sencilla del inversor directamente desde su smartphone con SolarEdge SetAppPequeño, el más ligero de su categoría, y fácil de instalar12-20AÑOS DE GARANTÍAPreparado para ampliación futura con soluciones de almacenamiento SolarEdgeProtección opcional frente a sobretensiones para CA de tipo 2 y RS485Protección contra sobretensiones en CC de tipo 2 integrada, para mejorar la resistencia en caso de tormentas o rayosInversor trifásicoSE25K / SE30K / SE33.3K(1) Si fuera necesaria una protección diferencial externa, su valor de disparo tiene que ser ≥ 100mA (2)Donde permitido por la normativa local(3)La conexión a internet por Wi-Fi requiere un componente Wi-Fi adicional, que se tiene que solicitar por separado. Para más detalles contactar con el departamento comercial de SolarEdge o hacer referencia a: https:///products/communication(4)Código de artículo del inversor con apagado rápido: SExxK-xxRxxxxxx(5) Para conocer todas las normativas consultar el apartado de Certificados en la página de Descargas: /groups/support/downloads(6) Entradas de CC disponible con conectores MC4 o prensaestopas según el código de producto del inversor . Para obtener más información, póngase en contacto con SolarEdge (7)Se permite solamente el uso de conectores MC4 fabricados por Stäubli.(8) Para más información consultar: https:///sites/default/files/se-temperature-derating-note.pdf.Aplicable a inversores con código de productoSEXXK -RWX0IXXXXSE25KSE30KSE33.3KSALIDAPotencia nominal de salida CA250002999033300WPotencia máxima de salida CA250002999033300VA T ensión nominal de salida CA: fase-fase / fase-neutro 380 / 220 ; 400 / 230Vca Rango de tensión de salida CA: fase-fase / fase-neutro304 - 437 / 176 - 253 ; 320 - 460 / 184 - 264,5VcaFrecuencia CA50/60 ± 5 %HzCorriente máxima de salida constante (por fase)36,2543,548,25AacPosibles conexiones de la línea de salida CA3 W + PE,4 W + PEMonitorización de red, protección contra funcionamiento en isla, factor de potencia configurable, umbrales configurables por país SíDistorsión armónica total < 3 %Rango de factor de potencia+/- 0.8 a 1Corriente de Derivación Máxima Inyectada(1)100mAENTRADAPotencia máxima de CC admitida (módulo STC) 437505250058275W Sin transformador, sin puesta a tierra SíT ensión nominal de entrada CC+ a CC-750VccCorriente máxima de entrada36,2543,548,25 AccProtección contra polaridad inversa SíDetección de fallo de aislamiento a tierraSensibilidad 150 kΩ(2)Rendimiento máximo del inversor98,3%Rendimiento ponderado europeo98%Consumo de energía nocturno <4WCARACTERÍSTICAS ADICIONALESInterfaces de comunicación 2 x RS485, Ethernet, Wi-Fi (Opcional)(3), T elefonía móvil (opcional)Gestión Smart EnergyLimitación de exportaciónPuesta en marcha del inversor Con la aplicación móvil SetApp utilizando la conexión Wi-Fi integrada para la conexión localProtección contra fallos de arcoIntegrado, configurable por el usuario (según UL1699B)Apagado rápidoOpcional (4) (Automático tras desconexión de la red de CA)Protección contra sobretensiones RS485OpcionalProtección contra sobretensiones de CCTipo II, reemplazable, integrada Protección contra sobretensiones de CA Tipo II, reemplazable, opcionalUNIDAD DE SEGURIDAD DE CC (OPCIONAL )Desconexión de 2 polos 1000 V / 48,25A Fusibles de CC Opcionales, 25ACumplimiento UTE-C15-712-1CUMPLIMIENTO DE NORMATIVASSeguridadIEC-62109 N ormas de conexión a la red (5)VDE-AR-N-4105, AS-4777, EN50438, CEI-021, VDE 0126-1-1, CEI-016, EN50549-1, EN50549-2,VDE-AR-N-4110, TOR Erzeuger Typ A, G99, G99 (NI), VFR 2019Emisiones IEC61000-6-2, IEC61000-6-3 Clase A, IEC61000-3-11, IEC61000-3-12RoHSSíESPECIFICACIONES PARA LA INSTALACIÓNDiámetro prensaestopas de salida de CA/Sección transversal de línea/Sección transversal de PE18 - 25 mm / 4 – 16 mm 2 / 4 – 16 mm 2Entradas de CC (6)4 pares MC4Entrada de CC con unidad de seguridad (6)(7)4 pares MC44 entradas por prensaestopas: Diámetro exterior del cable5 - 10 mm / Sección trasversal delcable 2.5 - 16mm 2Dimensiones (Al x An x P)550 x 317 x 273mmDimensiones con unidad de seguridad (Al x An x P)836 x 317 x 300 (DC MC4); 819 x 317 x 300 (DC Gland)mm Peso32kg Peso con unidad de seguridad 36,5kg Rango de temperatura de funcionamientoDe -40 a +85(8)˚CRefrigeración Ventilador (reemplazable por el usuario)Ruido<62dBAGrado de protección IP65 — exterior e interiorMontajeSobre soporte (suministrado)©SolarEdge Technologies, Inc. Reservados todos los derechos. SOLAREDGE, el logo de SolarEdge, OPTIMIZED BY SOLAREDGE son marcas comerciales o registradas de SolarEdge Technologies, Inc. Cualquier otra marca que se mencione en este documento es propiedad de su correspondiente titular. Fecha: 08/2022/V01/SP EU. Sujeto a cambios sin previo aviso.。

SUNGROW SG100K3 光伏逆变器 安装手册

SUNGROW SG100K3 光伏逆变器 安装手册

目录1 关于本手册 (1)1.1前言 (2)1.2内容简介 (2)1.3面向读者 (2)1.4手册使用 (3)1.5符号使用 (3)2 安全须知 (5)2.1光伏并网发电系统 (6)2.2安全使用说明 (7)3 交付 (9)3.1供货范围 (10)3.2识别SG100K3 (11)3.3存储 (12)4 产品描述 (13)4.1外型说明 (14)4.1.1外型尺寸 (14)4.1.2底部顶部视图 (15)4.2外部器件 (16)4.3电路介绍 (17)4.4接线端子 (18)5 安装设计 (19)5.1系统选配附件 (20)5.2基本安装要求 (21)5.3安装环境设计 (21)5.3.1地面要求 (21)5.3.2空间要求 (21)5.3.3线缆沟设计 (22)5.3.4通风要求 (22)5.3.5其他防护 (23)5.4布线规范 (23)5.5连接线缆的固定及防护 (24)5.5.1线缆的固定 (24)5.5.2线缆的防护 (24)5.6安装流程 (25)6 安装准备 (27)6.1安装前检查 (28)6.2安装工具及零件 (28)7 机械安装 (29)7.1运输机器 (30)7.1.1注意事项 (30)7.1.2带包装的运输 (31)7.1.3不带包装逆变器移动 (33)7.2现场安装 (35)8 电气连接 (37)8.1安全说明 (38)8.2输入输出要求 (39)8.3线缆要求 (39)8.4接线零部件 (40)8.5电气接线前准备 (41)8.5.1打开前门 (41)8.5.2取下防护罩 (42)8.5.3开启接线孔 (42)8.6直流侧接线 (43)8.7交流侧接线 (45)8.8接地连线 (47)8.9通讯连线 (48)9 安装检查清单 (51)10 试运行 (53)10.1试运行要求 (54)10.2试运行前的检查 (54)10.2.1检查光伏阵列 (54)10.2.2检查逆变器 (54)10.2.3检查逆变器电压 (55)10.3开机前准备 (55)10.4开机 (56)10.5完成试运行 (56)11 附录 (57)11.1技术数据 (58)11.2质量保证 (59)11.3关于阳光 (60)1 关于本手册关于本章本章介绍了本手册的主要内容、面向的读者、手册使用须知以及手册中所使用的符号释义,以帮助用户更好地阅读、使用本手册。

华为SUN2000-60KTL-M0(380 400Vac)逆变器技术参数说明书

华为SUN2000-60KTL-M0(380 400Vac)逆变器技术参数说明书

De-rating Behavior and P-Q Curve of Inverter SUN2000-60KTL-M0 (380_400Vac)Huawei Technologies Co., Ltd.1.Temperature De-rating Curve of SUN2000-60KTL-M0 (380/400Vac)Air speed: 0.5m/s, PF=12.PV Input voltage De-rating Curve of SUN2000-60KTL-M0(380/400Vac)Note:The PV input voltage de-rating curve works under condition that PF=1.0.3. ******************************.u.voltage(380/400Vac)P(kW)kVar)Note:When SUN2000-60KTL-M0 is in the condition that it operates at rated and 1.1 rated output voltage, it can output 66kW (when PF=1) or 66kV A at most.When SUN2000-60KTL-M0 is in the condition that it operates at 0.9 rated output voltage, it can output 59.4kW (when PF=1) or 59.4kV A at most.4.Max. PV Input Voltage vs. Altitude of SUN2000-60KTL-M0 (380/400Vac)Note:SUN2000 inverter design safety distance in accordance with running at the altitude of 4000m and below to avoid power de-rating. As altitude increases above 4000m, DC voltage de-rating of SUN2000 should be taken into consideration and DC voltage drop in accordance with 13V/100m. For SUN2000 inverter, the rated AC voltage will not be affected by the altitude.5.Maximum Working Temperature vs. Altitude of SUN2000-60KTL-M0(380/400Vac)Note:The maximum working temperature is the ambient temperature below which SUN2000 can output rated power without de-rating.When the altitude rises, the cooling capacity of the inverters de-rates. So the internal temperature of inverters in the high altitude area will be higher and severer than that in the low altitude area.When altitude > 2000m, the maximum working temperature of SUN2000 should de-rate by altitude, and it de-rates in accordance with 6℃/1000m.General Disclaimer:The information in this document may contain predictive statements including, without limitation, statements regarding the future financial and operating results, future product portfolio, new technology, etc. There are a number of factors that could cause actual results and developments to differ materially from those expressed or implied in the predictive statements. Therefore, such information is provided for reference purpose only and constitutes neither an offer nor an acceptance. Huawei may change the information at any time without notice.。

Growatt 1-5K-S组串式逆变器介绍

Growatt 1-5K-S组串式逆变器介绍

竞争对手产品对比分析
性能对比
与其他品牌同类产品相比,Growatt 1-5K-S组串式逆变器在转换效率、最大功率跟踪 精度等性能方面表现优异。
功能对比
该产品具备丰富的保护功能,如过压、欠压、过热等保护,确保系统安全稳定运行;同 时支持远程监控和智能管理功能,方便用户进行系统管理和维护。
价格对比
在性能和功能相近的情况下,Growatt 1-5K-S组串式逆变器的价格相对合理,具有较 高的性价比。
期发展奠定坚实基础。
THANK YOU
感谢观看
市场需求趋势预测
光伏市场持续增长
随着全球对可再生能源的重视和光伏技术的不断进步,光 伏市场将持续增长,组串式逆变器作为光伏系统核心部件 之一,市场需求将随之增加。
储能市场快速发展
随着能源转型和智能电网的推进,储能市场将快速发展, 组串式逆变器与储能系统的结合将成为市场新趋势。
智能化、高效率需求
客户对逆变器的智能化、高效率等性能要求不断提高,具 备这些特点的组串式逆变器将更受市场欢迎。
购买渠道
Growatt 1-5K-S组串式逆变器可通 过官方网站、授权经销商或合作伙伴 等渠道进行购买。
价格策略
Growatt根据不同市场需求和竞争状 况,制定有竞争力的价格策略,同时 提供灵活的付款方式和优惠政策,降 低客户的购买成本。
售后服务承诺及保障措施
售后服务承诺
Growatt承诺为客户提供全面的售后服务,包括产品安装、调试、维修等技术支持,确保客户在使用过程中遇到 问题能够得到及时解决。
故障处理
如遇到故障或异常情况, 请及时联系专业人员进行 维修处理,切勿自行拆卸 或修理。
04
应用领域与市场分析

330w电机参数

330w电机参数

330w电机参数如下:
330w电机的参数通常包括功率、工作制、冷却方式、能效等级以及适用场合等。

具体如下:
1. 功率:电机的额定功率为330瓦特(W),这是电机在正常运行时的输出功率。

2. 工作制:常见的电机工作制为S1,表示电机能够在连续不变的负荷下运行,不会过热。

3. 冷却方式:例如IC411,这表示电机采用封闭式冷却系统,其中IC代表间接冷却,数字表示具体的冷却方式。

4. 能效等级:中国GB18613-2020规定的3级能效(IE 3),这个标准衡量电机的能源利用效率。

5. 适用场合:330w电机适用于需要节能连续运行的一般使用场所,如风机、水泵、机床等。

6. 绝缘等级:F级绝缘,表示电机能够承受较高的温度而不会损坏。

7. 防护等级:IP55,第一个数字表示防尘能力,第二个数字表示防水能力,IP55意味着较好的防尘和防水性能。

8. 电机噪声和振动:低噪声和振动是电机运行时的舒适性指标,对于工作环境的安静和稳定有重要影响。

9. 电机极对数:电机的极对数决定了电机的同步转速,通常用于描述三相交流电机的相关参数。

京仪绿能逆变器参数

京仪绿能逆变器参数

光伏逆变器JYNB-3/5/6KVO (户外) JYNB-3/5/6KVI (户内)性能特点:• 先进的第四代IGBT 模块,可靠性强JYNB-3/5/6kW光伏并网逆变器参数说明型号:JYNB-3/5/6KVO JYNB-3/5/6KVI 直流侧参数最大直流功率 3.3kWp/5.5kWp/6.6kWp直流电压范围(MPPT) 270-600V最大直流电压 600V最大输入电流 12.5A /20.4A /24.5A最大输入路数 3交流侧参数额定输出功率 3kW/5kW/6kW额定电网电压 230Vac(允许波动±10%)额定电网频率 50Hz(允许波动±0.5Hz)供电系统 单相电压波动 < 3% (额定功率)总电流波形畸变率 < 3% (额定功率)功率因数 1(额定功率)过载能力 120%/1min短路保护 150%(<0.1s)系统最大效率 94.5%欧洲效率 94%防护等级 IP65(户外)、IP21(户内)夜间自耗电 0W允许环境温度 -25~+60℃(户外);-20~+40℃(户内)冷却方式 风冷允许相对湿度 0~95%,无凝露允许最高海拔 ≤2000米显示与通讯显示 液晶屏标准通讯方式 RS485可选通讯方式 GPRS机械参数宽x高x深 470x365x257mm重量45.5kg标准金太阳认证 具备电磁兼容测试 GB 17625.2-GB/T 17626.11光伏逆变器JYNB-30K性能特点:• 先进的第四代IGBT模块,可靠性强JYNB-30kW光伏并网逆变器参数说明型号:JYNB-30K输入参数推荐最大太阳电池阵列功率33 kWp直流电压范围(MPPT)450~820 V允许最大直流电压880 V最大阵列电流73AMPP跟踪快速、精确MPP跟踪接入方式铜排接入输出参数额定交流输出功率30 kW运行电网电压400VAC±10%额定交流电流43A供电系统 TT、TN-C、TN-S运行中的电网频率50Hz±0.5Hz电压波动<3%电网电流的谐波畸变<3%功率因数(额定功率下) 1过载能力120%/1min短路保护 150%/(<0.1s)尺寸和重量宽/高/深800/1600/600mm重量466kg功耗夜间工作模式自耗电≤Approx. 40W外部辅助供电无效率最大效率95.3%欧洲效率94%接口计算机接口RS485通讯以太网/GPRS保护等级和环境条件防护等级IP21绝缘等级50Hz AC 3Kv/1min爬电距离1kV/5mm防雷等级C(第II级)工作温度 -20℃ - +50℃风冷√相对湿度,不结露0-95%噪音<60 dB使用海拔高度<2000m电磁兼容测试GB 17625.2 – GB/T 17626.11光伏逆变器JYNB-100K/100KHEJYNB-100kW光伏并网逆变器参数说明类型:JYNB-100K/JYNB-100KHE 输入参数推荐最大太阳电池阵列功率110 kWp直流电压范围(MPPT)450~820 V允许最大直流电压880 V最大阵列电流245AMPP跟踪快速、精确MPP跟踪接入方式铜排接入输出参数额定交流输出功率100 kW运行电网电压400VAC±10% / 270VAC±10% 额定交流电流144A/214A供电系统 TT、TN-C、TN-S运行中的电网频率50Hz±0.5Hz电压波动<3%电网电流的谐波畸变<1%功率因数(额定功率下) 1过载能力120%/1min短路保护 150%/(<0.1s)尺寸和重量宽/高/深1000/2000/1000mm重量1230kg/800kg功耗夜间工作模式自耗电≤Approx. 40W外部辅助供电无效率最大效率98.5%/99%欧洲效率98.3%/98.8%接口计算机接口RS485通讯以太网/GPRS保护等级和环境条件防护等级IP21绝缘等级50Hz AC 3kV/1min爬电距离1kV/5mm防雷等级C(第II级)工作温度 -20℃ - +50℃风冷√相对湿度,不结露0-95%噪音<60 dB使用海拔高度<2000m电磁兼容测试GB 17625.2 – GB/T 17626.11光伏逆变器JYNB-250K/250KHEJYNB-250kW光伏并网逆变器参数说明类型:JYNB-250K/ JYNB-250KHE输入参数推荐最大太阳电池阵列功率275 kWp直流电压范围(MPPT)450~820 V允许最大直流电压880 V最大阵列电流611AMPP跟踪快速、精确MPP跟踪接入方式铜排接入输出参数额定交流输出功率250 kW运行电网电压400VAC±10% / 270VAC±10% 额定交流电流361A / 534A供电系统 TT、TN-C、TN-S运行中的电网频率50Hz±0.5Hz电压波动<3%电网电流的谐波畸变<3%功率因数(额定功率下) 1过载能力120%/1min短路保护 150%/(<0.1s)尺寸和重量宽/高/深1000+800 /2120/850mm重量2300kg / 1600kg功耗夜间工作模式自耗电≤Approx. 40W外部辅助供电无 /1x220V,50Hz效率最大效率98.2% / 98.6%欧洲效率98.0% / 98.4%接口计算机接口RS485通讯以太网/GPRS保护等级和环境条件防护等级IP21绝缘等级50Hz AC.3KV/1min爬电距离1kV/5mm防雷等级C(第II级)工作温度 -20℃ - +50℃风冷√相对湿度,不结露0-95%噪音<60 dB使用海拔高度<2000m电磁兼容测试GB 17625.2 – GB/T 17626.11光伏逆变器JYNB-500KHEJYNB-500kW光伏并网逆变器参数说明类型:JYNB-500KHE输入参数推荐最大太阳电池阵列功率550 kWp直流电压范围(MPPT)450~820 V允许最大直流电压880 V最大阵列电流 2 x 611AMPP跟踪快速、精确MPP跟踪接入方式铜排接入输出参数额定交流输出功率500 kW运行电网电压270VAC±10%额定交流电流1069A供电系统 TT、TN-C、TN-S运行中的电网频率50Hz±0.5Hz电压波动<3%电网电流的谐波畸变<2%功率因数(额定功率下) 1过载能力120%/1min短路保护 150%/(<0.1s)尺寸和重量宽/高/深1000+800/2120/850mm重量1800kg功耗夜间工作模式自耗电≤Approx. 40W外部辅助供电 1 x 220V,50Hz效率最大效率98.8%欧洲效率98.6%接口计算机接口RS485通讯以太网/GPRS保护等级和环境条件防护等级IP21绝缘等级50Hz AC.3KV/1min爬电距离1kV/5mm防雷等级C(第II级)工作温度 -20℃ - +50℃风冷√相对湿度,不结露0-95%噪音<60 dB使用海拔高度<2000m电磁兼容测试GB 17625.2 – GB/T 17626.11。

逆变器的主要参数之欧阳与创编

逆变器的主要参数之欧阳与创编

光伏逆变器的主要参数1 .额定输出电压在规定的输入电源条件下,输出额定电流时,逆变器应输出的额定电压值。

(电压波动范围:单相220V±5%,三相 380±5%。

)• 2.输出电压的稳定度在光伏系统中,太阳电池发出的电能先由蓄电池储存起来,然后经过逆变器逆变成220V或380V的交流电。

但是蓄电池受自身充放电的影响,其输出电压的变化范围较大,如标称12V的蓄电池,其电压值可在10.8~14.4V之间变动(超出这个范围可能对蓄电池造成损坏)。

对于一个合格的逆变器,输入端电压在这个范围内变化时,其稳态输出电压的变化量应不超过额定值的±5%,同时当负载发生突变时,其输出电压偏差不应超过额定值的±10%。

3.输出电压的波形失真度对正弦波逆变器,应规定允许的最大波形失真度(或谐波含量)。

通常以输出电压的总波形失真度表示,其值应不超过5%(单相输出允许l0%)。

由于逆变器输出的高次谐波电流会在感性负载上产生涡流等附加损耗,如果逆变器波形失真度过大,会导致负载部件严重发热,不利于电气设备的安全,并且严重影响系统的运行效率。

4.额定输出频率对于包含电机之类的负载,如洗衣机、电冰箱等,由于其电机最佳频率工作点为50Hz,频率过高或者过低都会造成设备发热,降低系统运行效率和使用寿命,所以逆变器的输出频率应是一个相对稳定的值,通常为工频50Hz,正常工作条件下其偏差应在±l%以内。

5.负载功率因数表征逆变器带感性负载或容性负载的能力。

正弦波逆变器的负载功率因数为0.7~0.9,额定值为0.9。

在负载功率一定的情况下,如果逆变器的功率因数较低,则所需逆变器的容量就要增大,一方面造成成本增加,同时光伏系统交流回路的视在功率增大,回路电流增大,损耗必然增加,系统效率也会降低。

6.逆变器效率逆变器的效率是指在规定的工作条件下,其输出功率与输入功率之比,以百分数表示,一般情况下,光伏逆变器的标称效率是指纯阻负载,80%负载情况下的效率。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
相关文档