的复用和分解方面原理上就是一个串并转换和并串转换
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
这个并串转换代码是依靠同步状态机来实现其控制的。其实并串转换在实际的电路中使用还是比较多的,尤其在通信线路方面的复用和分解方面,原理上就是一个串并转换和并串转换的过程。举个简单的例子,计算机串口发送数据的过程,如果满足发送条件了,其实就是一个并串转换的过程了。好了,废话不说,看代码就是。
--------------------------------------------------------------------------------
-- Engineer: skycanny
-- Module Name: p2s - Behavioral
-- Tool versions: ISE7.1
-- Description: This module is designed to implement parallel to serial conversion
--------------------------------------------------------------------------------
library IEEE;
use IEEE.STD_LOGIC_1164.ALL;
use IEEE.STD_LOGIC_ARITH.ALL;
use IEEE.STD_LOGIC_UNSIGNED.ALL;
entity p2s is
port(
reset : in std_logic;
clk : in std_logic;
start : in std_logic; --low active,data_in valid
data_in : in std_logic_vector(7 downto 0);
data_valid : out std_logic; --high active,output data valid
ready : out std_logic; --low active,ready to recieve data
q : out std_logic
);
end p2s;
architecture Behavioral of p2s is
signal reg : std_logic_vector(7 downto 0);
signal cnt : std_logic_vector(3 downto 0);
signal reg_en : std_logic;
signal shift_start : std_logic;
type state is (idle,recieve,shift,finish);
signal current_state, next_state : state;
begin
counter: process(reset,clk,shift_start)
begin
if(reset = '0') then
cnt <= (others => '0');
elsif(clk'event and clk = '1') then
if(shift_start = '0') then
cnt <= cnt + 1;
else
cnt <= (others => '0');
end if;
end if;
end process counter;
fsm: block
begin
sync: process(reset,clk)
begin
if(reset= '0') then
current_state <= idle;
elsif(clk'event and clk = '1') then
current_state <= next_state;
end if;
end process sync;
comb: process(current_state,cnt,start) begin
case current_state is
when idle =>
ready <= '0';
reg_en <= '1';
shift_start <= '1';
data_valid <= '1';
if(start = '0') then
reg_en <= '0';
next_state <= recieve;
else
next_state <= idle;
end if;
when recieve =>
reg_en <= '1';
ready <= '1';
data_valid <= '0';
shift_start <= '0';
next_state <= shift;
when shift =>
reg_en <= '1';
ready <= '1';
data_valid <= '0';
if(cnt = 8) then
shift_start <= '1';
next_state <= finish;
else
shift_start <= '0';
next_state <= shift;
end if;
when finish =>
reg_en <= '1';
ready <= '0';
data_valid <= '1';
shift_start <= '1';
next_state <= idle;
when others =>
next_state <= idle;
end case;
end process comb;
end block fsm;
data_channel: process(reset,clk)
begin
if(reset = '0') then
reg <= (others => '0');
q <= '0';
elsif(clk'event and clk = '1') then
if(reg_en = '0') then
reg <= data_in;
elsif(shift_start = '0') then
q <= reg(7);
for i in 7 downto 1 loop --shift register reg(i) <= reg(i - 1);