Vmware vSphere5.0虚拟机管理及硬件常见问题
VMware vSphere常见问题汇总(17)
VMware vSphere常见问题汇总(十七)170. Vmdk 的重做日志已损坏解题思路[vmware-]环境:esxi5.0,vc5.0故障问题:执行storage vmotion之后,虚拟机出现了报错。
报错信息:xssj-000003.vmdk is corrupted.power off the virtual machine. If the problem still persists, discard the redo log.解提思路:【故障原因】由于快照之间的关系出现异常,导致vm启动失败:Vmware-34.log:2013-01-14t08:36:53.885z| vmx| disklib-chain :"/vmfs/volumes/50f13506-075ed29b-86b5-5ef3fd359eab/???è???3????184/xssj-000005.vmdk" : failed to open (the parent virtual disk has been modified 34.log:2013-01-14t08:36:53.886z| vmx| disklib-lib : failed to open'/vmfs/volumes/50f13506-075ed29b-86b5-5ef3fd359eab/???è???3????184/xssj-000006.vmdk' with flags 0xa the parent virtual disk has been modified since the child was created. The content id of the parent virtual disk does not match the corresponding parent content id in the child (18).Vmware-34.log:2013-01-14t08:36:53.886z| vmx| disk: cannot open disk"/vmfs/volumes/50f13506-075ed29b-86b5-5ef3fd359eab/???è???3????184/xssj-000006.vmdk": the parent virtual disk has been modified since the child was created. The content id of the parent virtual disk does not match the corresponding parent content id in the child (18).Vmware-34.log:2013-01-14t08:36:53.886z| vmx| msg_post: errorVmware-34.log:2013-01-14t08:36:53.886z| vmx| [msg.disk.nobackend] cannot open the disk '/vmfs/volumes/50f13506-075ed29b-86b5-5ef3fd359eab/???è???3????184/xssj-000006.vmdk' or one of the snapshot disks it depends on.Vmware-34.log:2013-01-14t08:36:53.886z| vmx| [msg.disk.configurediskerror] reason: the parent virtual disk has been modified since the child was created. The content id of the parent virtual disk does not match the corresponding parent content id in the child.Vmware-34.log:2013-01-14t08:36:53.900z| vmx| module diskearly power on failed.【快照之间的联系】正常情况下,原始磁盘与快照是通过parent content id来关联,父快照与子快照之间也是通过parent content id,但是现在我们查看原始磁盘与快照磁盘之间的关系,发现它们的cid和parentcid是混乱的,信息如下:Xssj.vmdk:cid=ba60eb23Xssj.vmdk:parentcid=ffffffffXssj-000001.vmdk:cid=27f8a456Xssj-000001.vmdk:parentcid=ba60eb23Xssj-000002.vmdk:cid=11ed1dacXssj-000002.vmdk:parentcid=27f8a456Xssj-000003.vmdk:cid=2583a010Xssj-000003.vmdk:parentcid=2583a010Xssj-000004.vmdk:cid=2583a010Xssj-000004.vmdk:parentcid=11ed1dacXssj-000005.vmdk:cid=4d38fabfXssj-000005.vmdk:parentcid=2583a010Xssj-000006.vmdk:cid=9402bf1aXssj-000006.vmdk:parentcid=a30d0e91可以看到这个磁盘关系从xssj.vmdk磁盘到xssj-000002.vmdk之间的关系都是没有问题的。
VMwarevSphere常见问题汇总——ESXi主机、vCenterServer
VMwarevSphere常见问题汇总——ESXi主机、vCenterServer 1. 查看ESXi主机的管理服务的运⾏状态⽅式 (1)打开DUCI的Local ESXi Shell,然后Alt+F1进⼊到命令界⾯; (2)执⾏如下命令查看hostd服务是否正常运⾏: /etc/init.d/hostd status 输出类似如下结果: hostd is running (3)如果ESXi主机有连接到vCenter Server则还可以查看vCenter Server位于ESXi主机上的Agent是否正常: /etc/init.d/vpxa status 输出类似如下结果: vpxa is running 2、 vCenter Server 5.0 Update1的Service Status页标签显⽰License Services警报 故障状态 (1)vCenter Service Status页标签显⽰License Services警报; (2)系统提⽰如下错误警报: Threshold Usage Tracking service Alert Cannot obtain user-defined license thresholds Asset properties History service Alert Cannot store hosts' MAC addresses in thevCenter Server database Assignments Feeding service Alert Cannot obtain license assignments for VRAMusage License Usage History service Alert Cannot store license usage in vCenter Serverdatabase故障分析 故障分析 这个问题⼀般都是由于当升级vCenter Server到U1时VirtualCenter ManagementWebservices运⾏在AD账户下,这就可能导致Update之后的账户匹配关联丢失,进⽽导致服务⽆法启动; 解决⽅案 解决⽅案 (1)进⼊到Windows的服务管理器,然后打开VMware VirtualCenter ManagementWebservices的Properties选项; (2)点击Log On的页标签,更改账户关联,然后重启服务即可。
VMware vSphere 5.0安装与配置手册
配置 ESXi:其他设置
利用 DCUI,管理员可以: 配置键盘布局 查看支持信息 查看系统日志 在必要时启用故障排除服务
VMware vSphere:安装、配置、管理 – 修订版 A Confidential
2-40
版权所有 © 2011 VMware Inc 。保留所有 权利 © 2010 VMware Inc. All rights reserved
虚拟化 简介
VMware vSphere 5:安装、配置、管理 – 修订版 A
2
物理体系结构与虚拟体系结构
物理体系结构
虚拟体系结构
应用程序
操作系统
VMware vSphere x86 体系结构
x86 体系结构
VMware vSphere:安装、配置、管理 – 修订版 A
Confidential
2-9
虚拟机
• • •
支持员工只接受了针对 Windows 操作系统的培训 应用程序依赖于特定的 Windows 版本 希望使用物理主机
作为运行 SuSE Linux 操作系统的虚拟设备部署
基于 Linux
• • •
不需要操作系统许可证
可使用 Web 浏览器执行简单的配置 提供与基于 Windows 的版本相同的用户体验
Confidential
4-8
版权所有 © 2011 VMware inc 。保留所有 权利 © 2010 VMware Inc. All rights reserved
vCenter Server 部署选项
物理主机
-或-
部署在物理主机或虚拟机上并且安装了受支持的 Windows 版本。
使用基于 Windows 的 vCenter Server 而不使用 vCenter Server 虚拟设备的原因
VmwarevSphere5.0虚拟机管理及硬件常见问题
VmwarevSphere5.0虚拟机管理及硬件常见问题Vmware vSphere5.0虚拟机管理及硬件常见问题虚拟机管理问题早于2.6.27 版本的Linux 内核不报告处于关闭电源状态的每插槽内核数为2从ESXi 5.0 开始,多核虚拟CPU 支持允许处于关闭电源状态的每插槽内核数为2。
早于 2.6.27 版本的Linux 内核仅正确报告处于打开电源状态的每插槽内核数为2。
例如,当您在 .vmx 文件中设置numvcpus = 6和cpuid.coresPerSocket = 3时,一些Linux 客户机操作系统可能无法报告任何物理标识信息。
Linux 内核2.6.28 及更高版本会正确报告CPU 和内核拓扑。
解决办法:无将内存热添加到使用Linux 64 位或Windows 7、32 位客户机操作系统的虚拟机时,无法将现有虚拟内存增加到 3 GB 以上下列情况适用于将内存热添加到使用Linux 64 位或Windows 7 32 位客户机操作系统的虚拟机。
如果已打开电源的虚拟机的内存少于3 GB,则内存热添加量不能超过3 GB。
如果虚拟机内存为1 GB,则可以添加2 GB。
如果虚拟机内存为2 GB,则可以添加1 GB。
如果虚拟机的内存为3444 MB,则可以添加128 MB。
如果已打开电源的虚拟机的内存正好为3 GB,则无法热添加任何内存。
如果已打开电源的虚拟机的内存超过 3 GB,则可以将虚拟机内存增加到虚拟机打开电源时初始内存大小的16 倍或增至硬件版本限制(以两者中较小者为准)。
硬件版本7 的限制是255 GB,硬件版本8 的限制是1011 GB。
如果在虚拟机电源打开时,内存从小于或等于 3 GB 增长到大于 3 GB,则Linux 64 位和32 位Windows 7 客户机操作系统会冻结。
此vSphere 限制可确保您不会在客户机操作系统中触发该错误。
解决办法:无。
在硬件版本7 虚拟机上进行CPU 热添加时出错硬件版本8 虚拟机的多核虚拟CPU 功能支持虚拟CPU 热添加。
VMware vSphere5管理手册
Vsphere5管理手册目录1.ESXI5和客户虚拟机安装过程 (1)1.1.ESX I安装过程 (1)1.2.ESX I初始配置过程 (9)1.3. V C LIENT安装过程 (13)1.4.安装G UEST操作系统 (18)1.4.1. 创建虚拟机(VM) (18)1.4.2. 安装操作系统 (27)1.4.3. 安装VMware Tools (29)2.VMWARE VCENTER安装过程 (29)2.1.准备V C ENTER安装环境 (29)2.2. V C ENTER安装 (30)2.3. V C ENTER中建立数据中心和集群 (39)2.4. V C ENTER中添加ESX I主机到集群 (45)3.VMWARE VSHERE5管理 (47)4.1克隆 (47)4.2克隆为模板 (51)4.3利用模板部署新的虚拟机 (56)4.4模板转换为虚拟机 (60)4.VMWARE VSHERE5维护 (63)4.1.查看ESX S ERVER信息 (63)4.1.1.查看ESX Server资源利用 (63)4.1.2. 查看ESX Server性能 (63)4.1.3. 查看ESX Server任务与事件 (64)4.1.4. 查看ESX Server映射关系 (64)4.1.5. 查看ESX Server硬件状态 (65)4.2.查看GUEST虚拟机信息 (65)4.2.1.查看虚拟机资源利用 (65)4.2.2. 查看虚拟机性能 (66)4.2.3. 虚拟机任务与事件 (66)4.2.4. 查看虚拟机的映射关系 (67)1.ESXi5和客户虚拟机安装过程1.1.ESXi安装过程vSphere5是VMware公司推出的一套服务器虚拟化解决方案,目前的最新版本为5.0。
vSphere5中的核心组件为VMware ESXi 5.0.0(取代原ESX),它是一款可以独立安装和运行在祼机上的系统,因此与他我们以往见过的VMware Workstation软件不同的是它不再依存于宿主操作系统之上。
Vmware vSphere常见问题及解决办法
VmwarevSphere常见问题及解决办法1. 虚拟机文件被锁,无法正常 power on故障状态:启动虚拟机时95%,停顿并且进程中断,提示:ubable to access files since it is locked。
祸根:HA解决方法:(1)首先将cluster中的HA功能关闭。
如果该功能不关闭,容易造成死锁,,VM不断跳动,,不断再不同的ESX内循环被锁,徒劳而无功。
(2)磁盘文件被锁,要解决,必须要知道到底是哪台ESX把他给锁住了,这是关键。
方法:看/var/log/vmkernel但是,在做这些前, 再准备些别的工作。
(3)在VC中,把被锁的VM从Inventory中remove掉。
原因很简单,这是一个 unregister的过程。
(4)根据/var/log/vmkernel,搜索owner,可以找到类似以下的语句: Oct 19 04:23:33 esx-hostname vmkernel: 3:06:29:47.992 cpu6:1656)FS3:1975: Checking if lock holders are live for lock [type 10c00001 offse t 52008960 v 380, hb offset 3554304 Oct 19 04:23:33 esx-hostname vmk ernel: gen 17, mode 1, owner 48f5f637-462688bc-fd28-0e1a6434b6f8 mti me 38112]OK,owner后面的48f5f637-462688bc-fd28-0e1a6434b6f8就是你的target 了。
因为他就是锁住VM 的宿主.。
(5)根据以下命令,,找出到底哪台ESX的UUID是 48f5f637-462688bc-fd28-0e1a6434b6f8[root@esxhostname root]# esxcfg-info |grep -i 'system uuid'(6)找到目标主机后,当然是杀死他锁住VM的进程。
Vmware vSphere常见问题汇总
Vmware vSphere常见问题汇总1、启用客户机操作系统和远程控制台之间的复制和粘贴操作解决方法:要在客户机操作系统和远程控制台之间进行复制和粘贴,必须使用vSphere Client 启用复制和粘贴操作。
步骤a、使用vSphere Client 登录到vCenter Server 系统并选择虚拟机。
b、在摘要选项卡中,单击编辑设置。
c、选择选项> 高级> 常规,然后单击配置参数。
d、单击添加行,并在“名称”和“值”列中键入以下值。
名称值isolation.tools.copy.disable falseisolation.tools.paste.disable false注意这些选项将替代在客户机操作系统的VMware Tools 控制面板中做出的任何设置。
e、单击确定以关闭“配置参数”对话框,然后再次单击确定以关闭“虚拟机属性”对话框。
f、重新启动虚拟机。
2、sco系统迁移过去之后找不到启动列表解决方法:目前解决方法:使用软驱制作应急盘,通过应急盘来找到启动列表,如果不行的话,只能使用,现成的虚拟镜像导入vmware中,但是这种方法,要自己设置与自己相关的应用。
3、linux做迁移时手动添加的逻辑分区(LVM卷),迁移过去之后找不到这些分区解决方法::给虚拟机额外添加硬盘后融合,然后将数据重新拷入加入的硬盘中。
4、安装esxi的时候找不到万兆网卡解决方法:解决方法:安装各个厂商OEM的esxi版本。
5、迁移时提示vss原卷不能克隆解决方法:解决方法:查看是否有额外的设备插在服务器上,如usb设备。
6、Windows迁移之后,配置网卡的时候,会提示“IP已经被分配给其他的适配器”解决方法:打开命令行窗口(运行cmd),输入:(1)、set DEVMGR_SHOW_NONPRESENT_DEVICES=1(2)、devmgmt.msc在弹出的“设备管理器”窗口。
选择“查看(V)”—“显示隐藏的设备(W)”,然后展开“网络适配器”子项,可以看到一些透明图标显示的网卡信息,这些信息是源服务器的物理网卡信息。
vSphere 故障排除
vSphere 故障排除Update 1ESXi 5.0vCenter Server 5.0在本文档被更新的版本替代之前,本文档支持列出的每个产品的版本和所有后续版本。
要查看本文档的更新版本,请访问/cn/support/pubs。
ZH_CN-000849-00vSphere 故障排除2 VMware, Inc.最新的技术文档可以从VMware 网站下载:/cn/support/pubs/VMware 网站还提供最近的产品更新信息。
您如果对本文档有任何意见或建议,请把反馈信息提交至:docfeedback@版权所有 © 2009–2012 VMware, Inc. 保留所有权利。
本产品受美国和国际版权及知识产权法的保护。
VMware 产品受一项或多项专利保护,有关专利详情,请访问 /go/patents-cn 。
VMware 是 VMware, Inc. 在美国和/或其他法律辖区的注册商标或商标。
此处提到的所有其他商标和名称分别是其各自公司的商标。
VMware, Inc.3401 Hillview Ave.Palo Alto, CA 北京办公室北京市海淀区科学院南路2号融科资讯中心C 座南8层/cn 上海办公室上海市浦东新区浦东南路 999 号新梅联合广场 23 楼/cn 广州办公室广州市天河北路 233 号中信广场 7401 室/cn目录关于 vSphere 故障排除51虚拟机故障排除7容错虚拟机故障排除7排除 USB 直通设备故障10在 vSphere Client 中恢复孤立的虚拟机11在 vSphere Web Client 中恢复孤立的虚拟机12从模板克隆或部署后未打开虚拟机电源122主机故障排除15vCenter Server 和 ESXi 主机证书故障排除15vSphere HA 主机状况故障排除17Auto Deploy 故障排除20排除 vCenter Server 插件故障25链接模式故障排除26配置 VMware 清单服务的日志记录28身份验证标记操作错误28活动目录规则集错误导致主机配置文件合规性故障293群集故障排除31vSphere HA 接入控制故障排除31检测信号数据存储故障排除33vSphere HA 故障切换故障排除34排除网络分区中的 vSphere Fault Tolerance 故障35Storage I/O Control 故障排除36存储 DRS 故障排除38直接连接到主机时无法创建资源池424存储故障排除45解决 SAN 存储器的显示问题45解决 SAN 性能问题47具有 RDM 的虚拟机需要忽略 SCSI INQUIRY 缓存50在不需要时启用软件 iSCSI 适配器50无法挂载 NFS 数据存储51了解 SCSI 感知代码515故障排除许可53主机许可故障排除53许可证报告故障排除55无法打开虚拟机电源58VMware, Inc. 3vSphere 故障排除无法将内存热插拔至虚拟机58无法将许可证密钥分配给 vCenter Server59无法配置或使用功能59索引614 VMware, Inc.关于 vSphere 故障排除《vSphere 故障排除》介绍了 vCenter Server 实施及相关组件的故障排除问题和过程。
VmwareVSphereESXi5.0.0update1安装和基本配置(全截图)
VmwareVSphereESXi5.0.0update1安装和基本配置(全截图)Vmware VSphere ESXi 5.0.0 Update 1安装和基本配置一、安装过程1.1、调整服务器的BIOS设置,将处理器的虚拟化支持打开,VT 等;如果不打开,可能不能正常安装;1.2、将光盘放入光驱后,启动服务器,到下面的界面直接回车,继续安装1.3、选择,从光盘安装ESXi服务器1.4、然后到下面的加载界面1.5、选择回车,继续安装1.6、接受最终用户许可协议1.7、选择安装的磁盘,如果有多块磁盘,选择需要安装到的磁盘1.8、选择键盘布局1.9、输入root帐号的密码1.10、开始扫描硬件准备安装;1.11、确认安装,按F111.12、开始安装过程;1.13、安装完成,按回车重新启动服务器;1.14、重启的过程;二、基本配置2.1、服务器重启启动过程,加载Vmware ESXi系统;2.2、系统启动完成后,呈现下面的界面2.3、登录进入配置模式,按F2,输入root帐号的密码2.5、选择IP配置2.6、将IP指定为静态IP,将IP地址配置为需要的配置完后,按回车确认2.8、选择指定DNS服务器,配置DNS服务器地址和本机的主机名2.9、配置完成后,按EXIT选择Y,确认重启网络服务2.10、按EXC退出到此,基本配置完成,可以通过Vmware VSphere Client登录服务器进行管理配置。
三、配置命令行实际管理工作中进程需要使用命令行,ESXi的服务器需要进行简单的配置才能使用本地命令行控制台和SSH远程访问服务。
3.1、在主机控制台的字符界面,按F2进入配置模式,选择排错选项3.2、选择激活ESXi Shell确认前在右边显示ESXi Shell is Disabled 回车确认激活确认后在右边显示ESXi Shell is Enabled 按EXC退出3.3、登录本地命令行控制台按Alt+F1,进入命令行控制台登录输入root帐号和密码,登录到命令行3.4、配置SSH,选择Enable SSH这时候,服务器能ping同,但SSH服务不同。
VMware vsphere经常出现的问题
一常见问题1 vSphere client 登陆语言如何选择vSphere client在安装时是根据你操作系统的语言版本来确定安装时选择的默认语言,一般我们都使用中文,但是很多中文报错信息在网上都无法搜索到解决方案,但是英文报错解决方案的结果往往会更多,所以我们有时候需要使用英文语言来登录vSphere client,这样查看警告错误信息时在网络中搜索会有更多的解决方案和结果。
更改vCenter的语言,您可以采取以下方法之一:1. 将vCenter Server系统的语言设置为"英文"2. 右键vSphere Client -> 属性-> 快捷方式-> 目标->在vSphere Client路径后加上-locale en_US"例如:"C:\Program Files\VMware\Infrastructure\Virtual InfrastructureClient\Launcher\VpxClient.exe" -locale en_US"若想vSphere client 使用中文语言登陆,需要编辑vSphere client快捷方式路径后加上-locale zh_CN"。
2 HA提示没有管理网络冗余信息1)现象在配置VMware HA后出现如下信息:VMware HA提示没有管理网络冗余信息Host <xxx> currently has no management network redundancy.2)两种解决方案1. 在不同的vSwitch和子网上添加第二个服务控制器或在服务控制台的vSwitch上添加第二个vmnic.2. VMware Infrastructure Client->Cluster->Edit Settings->VMware HA ->Advanced Options, 在选项列中,输入das.ignoreRedundantNetWarning,并设置值为true后确定->Reconfigure HA。
VMware vSphere常见问题汇总
1. 解决vcenter single sign style="background-image: none; border-bottom: 0px; border-left: 0px; padding-left: 0px; padding-right:0px; border-top: 0px; border-right: 0px; padding-top: 0px"title="clip_image002" border="0"src="/uploads/allimg/130222/03145I160-0.jpg" "653" height="450" />而系统出现这个错误后,所有已安装的进程都全部回滚了。
解决办法:经过查证显示vcenter single sign style="background-image: none; border-bottom: 0px; border-left: 0px; padding-left: 0px; padding-right: 0px; border-top: 0px; border-right: 0px; padding-top: 0px" title="clip_image004" border="0"src="/uploads/allimg/130222/03145M1P-1.jpg" "671" height="373" />完成上述动作后,再次尝试安装,搞定。
备注:在vsphere 5.1里,如果选用安装版本的vcenter server 5.1,请务必按照先后顺序,先部署vcenter single sign color="#ff0000">2. VMware vSphere日志收集方式通过命令行进行日志文件的收集(推荐方式):1. 以root用户登录esx server console命令行2. 进入到tmp目录:# cd /tmp3. 收集日志:# /usr/bin/vm-support4. 收集动作完成后,在tmp目录下将产生:<fqdn>-esxsupport-yyyy-mm-***************日志文件通过vi client进行诊断信息的收集:1. 以administrator身份通过vi client登陆virtualcenter或以root用户身份直接登陆esxi。
VMware vSphere 5 虚拟机管理
VMware vSphere 5.1 虚拟机管理在上一次中我们安装了强大的VMware vCenter管理中心,通过VMware vSphere Client 连接到VMware vCenter管理中心, vSphere的两个核心组件是VMware ESXi和VMware vCenter Server。
ESXi是用于创建和运行虚拟机的虚拟化平台。
vCenter Server 是一种服务,充当连接到网络的ESXi主机的中心管理员。
vCenter Server 可用于将多个主机的资源加入池中并管理这些资源。
vCenter Server 还提供了很多功能,用于监控和管理物理和虚拟基础架构。
可以对整个虚拟化平台进行管理,也是作为一个虚拟机管理员在日常生活中对虚拟机的运维工作,同样是虚拟机管理员常用的几个方法,保障虚拟机的正常运作。
管理员可以使用多种方法创建虚拟机并将其部署到vsphere数据中心。
可以创建单个虚拟机,然后在其中安装客户机操作系统和VMware Tools。
可以在现有的虚拟机中克隆或创建模板,或部署OVF 模板。
使用快照捕获虚拟机的状况,包括虚拟机内存、设置和虚拟磁盘的情况。
如果需要,可以回滚至上一个虚拟机状态,这样可减少误操作对虚拟机的破坏。
从而正在的使用虚拟化平台。
在虚拟化平台里,通过VMware vSphere Client连接到VMware vCenter管理中心,是日后操作虚拟化的主要途径,都是通过Client或者是Web Client来进行管理。
主要能管理大量的主机服务器和虚拟机,以满足大量快速部署虚拟机工作,完成虚拟机的监控和快照,将虚拟机数据快速转移和快速复制,并且能按照计划自动对虚拟机进行日常的维护,解决虚拟机在平时工作中发生异常的现象。
这些都是在以前物理机上无法完成的事情。
由于篇幅和时间限制,所以在本次虚拟化系列VMware vSphere 5.1虚拟机管理中,主要介绍下一内容:一、在ESXi中部署虚拟机二、虚拟机的克隆三、重新封装操作系统四、创建自定义规范五、使用规范部署虚拟机六、使用WEB Clinet管理虚拟机七、使用workstation 9.0 管理虚拟机以上的是本次中所讲的内容,对于初学者来说,本章比较重要,对于高手们来说,这只是平常的一些操作罢了。
VMware vSphere vCenter Server 管理 V5.0
VSTP笔记VMware vSphere vCenter Server 管理[V5.0]深圳市脑立方科技有限公司售前工程师:Arno Wang2013-4-13立方服务™为中国领先的Linux技术服务品牌版本修改历史记录类别:A-增加M-修改D-删除目录1课程内容 (6)2什么是VMware vCenter (6)2.1vCenter元素1 (7)2.2vCenter元素 2 (7)2.3vSphere 数据中心的物理拓扑结构 (7)2.3.1vCenter Server 的主要组件 (8)2.3.2vCenter Server 的可选组件 (9)2.3.3vCenter Server 接口 (9)2.4vCenter Server Appliance (10)2.4.1vCenter Server Appliance (10)2.4.2部署vCenter Server Appliance (10)2.4.3登陆vCenter Server Appliance Web控制台 (10)2.4.4vCenter Server Appliance 配置数据库 (11)2.4.5vCenter Server Appliance 配置网络 (11)2.4.6vCenter Server Appliance 配置身份验证 (11)2.4.7vCenter Server Appliance 启动服务 (11)2.5访问vCenter (11)2.5.1vSphere Web Client 要求 (12)2.5.2vSphere Web Client 应用 (13)2.5.3使用vSphere Web Client 1 (13)2.5.4使用vSphere Web Client 2 (13)2.5.5演示—安装和使用vSphere Web Client (13)3控制访问 (14)4网络和数据库存储级别的权限 (14)5简单搜索和高级搜索 (14)6vCenter 链接模式 (15)6.1什么是vCenter 链接模式 (15)6.2vCenter 链接模式的用途 (15)6.3vCenter 链接模式体系架构 (16)6.4vCenter 链接模式下的搜索过程 (16)6.5创建vCenter 链接模式的基本工作流程 (16)6.6准备vCenter Server 以应用vCenter 链接模式 (17)7主机配置文件 (18)7.1什么是主机配置文件 (18)7.2vSphere 5.0 中主机配置文件 (19)7.3创建主机配置文件的工作流程 (19)7.4查看和编辑主机配置文件 (19)7.5演示—创建、配置和应用主机配置文件 (20)8Orchestrator (20)8.1什么是Orchestrator (20)8.2访问Orchestrator (21)8.3Orchestrator 体系结构 (21)8.4Orchestrator Configuration 界面 (22)8.5工作流程 (23)8.6工作流程视图 (24)9单元总结 (24)10课程内容 (26)11APP (26)11.1什么是vApp (26)11.2vApp 格式 (27)11.3vApp 软件包 (27)11.4部署vApp (27)11.5演示—创建和配置vApp (28)11.6演示—导出和导入vApp (28)12警报 (28)12.1警报概述 (28)12.2触发器和操作 (28)12.3警报触发器类型 (29)12.4状态和条件触发器 (29)12.5事件触发器 (29)12.6警报操作 (30)12.7确认已触发的警报 (30)13性能图表 (30)13.1性能图表概述 (30)13.2使用性能图表 (31)13.3VMware Tools 中的Perfmon DLL (31)13.4资源图 (32)13.5单元总结 (32)VWware vCenter概述欢迎学习“VMware vCenter 概述”单元!请注意,本课程是使用VMware vSphere 软件的正式发布之前的版本开发的。
Vmware vSphere疑难问题解决方法
Vmware vSphere疑难问题解决方法导读:这里汇总了10个Vmware vSphere常见的问题:清除vSphere Client的登录记录、Linux系统VMXNET3虚拟网路卡时UDP包被Drop掉等,并给出了具体的解决办法。
关键词:VMware vSphere1、清除vSphere Client的登录记录使用vSphere Client连接多了,下拉列表里有很多的历史记录,看着有点烦。
搜索了下,找到了E文的操作办法定位注册表到HKEY_CURRENT_USER\Software\VMware\VMware InfrastructureClient\Preferences清除RecentConnections 的记录即可2、Linux系统VMXNET3虚拟网路卡时UDP包被Drop掉故障状态:ESXi 5.x系统上的Linux虚拟机,虚拟网路卡选择为VMXNET3时,UDP包被Drop掉了;故障分析:这是一个技术bug,VMware正在着手解决;解决方案:作为变通手段,只需要将VMXNET3改为E1000这个虚拟网路卡类型即可。
3、恢复孤立的虚拟机故障状态:虚拟机显示在 vSphere Client 清单列表中,其中 (orphaned) 附加到其名称。
故障分析:在极少数情况下,位于由 vCenter Server 管理的 ESXi 主机上的虚拟机可能会变为孤立状态。
vCenter Server 数据库中存在这些虚拟机,但 ESXi 主机不再能识别出它们。
故障原因:如果主机故障切换失败,或直接在主机上取消对虚拟机的注册时,虚拟机可能会变为孤立状态。
如果发生这种情况,请将孤立的虚拟机移动到数据中心(该数据中心可访问其中存储着虚拟机文件的数据存储)中的其他主机。
解决方案:(1)在 vSphere Client 清单列表中,右键单击虚拟机,然后选择重定位。
此时将显示可用主机列表。
(2)选择要在其中放置虚拟机的主机。
(整理)VMwarevSphere的超多问题QA.
VMware vSphere的超多问题Q & A文档Q:在Intel和AMD混合的ESXi/EX主机中需要注意哪些关键问题?A:a.DRS可以在同一Cluster里的所有主机之间执行资源负载均衡检测;b.VMware HA的故障切换可以在同一Cluster里的所有主机之间执行;c.vMotion不能在ESXi/ESX主机之间执行;d.FT不能再ESXi/ESX主机之间执行;e.Storage vMotion可以得到执行;f.DPM不能得到执行;Q:使用VMware Data Recovery时,最重要的一点是什么?A:Data Recovery客户端插件必须安装到vCenter Server上;Q:如果将虚拟机从Resource Pool里移除掉,那么,Resource Pool的Shares分配总量会发生什么变化?A:如果设定了自定义份额值则不会发生任何变化,如果设定为High、Medium或Low时,则会自动增加;Q:在ESX主机的Web Home页面可以做哪些事情?A:a.下载vCenter Server;b.浏览Datastores;c.浏览主机所管理的相关对象;Q:当安装ESX 4时,Service Console在什么位置?A:整个VMDK都会放到本地VMFS Datastore;Q:ESX 4.0缺省的swap分区是多大?A:600MB;Q:调整什么分区会更改缺省的/分区?A:/usr分区;Q:缺省情况下,额外的license需要授权,那么,以什么为基数开始?A:8颗或更多;Q:尝试在DRS Cluster里迁移VM,但是提示CPU兼容性故障,那么,基本情况应该怎么处理?A:a.确认CPU功能是否兼容,然后在有问题的主机BIOS里禁止掉;b.在DRS Cluster里激活EVC;Q:在作了什么动作之后,可以提升虚拟机的性能?A:a.增加CPU份额值;b.增加虚拟机CPU数量;Q:针对vNetwork Standard Switch的VLAN和端口组而言,怎么样的描述是对的?A:a.可以同时为vSwitch和/或Portgroups配置VLAN;b.VLANs只能够配置在独立的Portgroups上;c.也不能为同一个portgroup配置多个VLANs;Q:尝试为ESX执行Boot from SAN LUN时,ESX无法检测到HBA卡,什么原因最可能导致这个问题?A:HBA BIOS没有激活;Q:哪些vSphere Small Buiness和Medium/Enterprise版本中会包含Data Recovery?A:vSphere Essentials Plus和vSphere Advanced;Q:当无法远程管理和访问ESXi主机时,最有效的几种方式是什么?A:a.重启管理Agents;b.重置Standard Switch;c.测试管理网络;Q:配置vSphere 4 Host Update utility可以用来干什么用?A:a.执行主机兼容性检测;b.升级单独的ESXi/ESX主机;(4.1开始不支持ESX了)Q:升级到vSphere 4之后,最急需做的是哪些事情?A:a.配置license;b.验证虚拟机的相关操作是否正常;c.连接ESXi/ESX主机到vCenter;Q:升级ESX主机前,最需要做的事情是?A:备份/etc/passwd、/etc/groups、/etc/shadow、/etc/gshadow、自定义脚本和本地VMFS系统;Q:尝试为ESX主机配置Fixed Mulipathing Policy路径选择策略,且ESX有4个VMFS Datastores和4条可用路径时。
VMware vSphere常见问题汇总(17)
VMware vSphere常见问题汇总(十七)170. Vmdk 的重做日志已损坏解题思路[vmware-]环境:esxi5.0,vc5.0故障问题:执行storage vmotion之后,虚拟机出现了报错。
报错信息:xssj-000003.vmdk is corrupted.power off the virtual machine. If the problem still persists, discard the redo log.解提思路:【故障原因】由于快照之间的关系出现异常,导致vm启动失败:Vmware-34.log:2013-01-14t08:36:53.885z| vmx| disklib-chain :"/vmfs/volumes/50f13506-075ed29b-86b5-5ef3fd359eab/???è???3????184/xssj-000005.vmdk" : failed to open (the parent virtual disk has been modified 34.log:2013-01-14t08:36:53.886z| vmx| disklib-lib : failed to open'/vmfs/volumes/50f13506-075ed29b-86b5-5ef3fd359eab/???è???3????184/xssj-000006.vmdk' with flags 0xa the parent virtual disk has been modified since the child was created. The content id of the parent virtual disk does not match the corresponding parent content id in the child (18).Vmware-34.log:2013-01-14t08:36:53.886z| vmx| disk: cannot open disk"/vmfs/volumes/50f13506-075ed29b-86b5-5ef3fd359eab/???è???3????184/xssj-000006.vmdk": the parent virtual disk has been modified since the child was created. The content id of the parent virtual disk does not match the corresponding parent content id in the child (18).Vmware-34.log:2013-01-14t08:36:53.886z| vmx| msg_post: errorVmware-34.log:2013-01-14t08:36:53.886z| vmx| [msg.disk.nobackend] cannot open the disk '/vmfs/volumes/50f13506-075ed29b-86b5-5ef3fd359eab/???è???3????184/xssj-000006.vmdk' or one of the snapshot disks it depends on.Vmware-34.log:2013-01-14t08:36:53.886z| vmx| [msg.disk.configurediskerror] reason: the parent virtual disk has been modified since the child was created. The content id of the parent virtual disk does not match the corresponding parent content id in the child.Vmware-34.log:2013-01-14t08:36:53.900z| vmx| module diskearly power on failed.【快照之间的联系】正常情况下,原始磁盘与快照是通过parent content id来关联,父快照与子快照之间也是通过parent content id,但是现在我们查看原始磁盘与快照磁盘之间的关系,发现它们的cid和parentcid是混乱的,信息如下:Xssj.vmdk:cid=ba60eb23Xssj.vmdk:parentcid=ffffffffXssj-000001.vmdk:cid=27f8a456Xssj-000001.vmdk:parentcid=ba60eb23Xssj-000002.vmdk:cid=11ed1dacXssj-000002.vmdk:parentcid=27f8a456Xssj-000003.vmdk:cid=2583a010Xssj-000003.vmdk:parentcid=2583a010Xssj-000004.vmdk:cid=2583a010Xssj-000004.vmdk:parentcid=11ed1dacXssj-000005.vmdk:cid=4d38fabfXssj-000005.vmdk:parentcid=2583a010Xssj-000006.vmdk:cid=9402bf1aXssj-000006.vmdk:parentcid=a30d0e91可以看到这个磁盘关系从xssj.vmdk磁盘到xssj-000002.vmdk之间的关系都是没有问题的。
Vmware vSphere5.0网络连接服务器配置常见问题 txt
(11)服务器配置问题
应用关闭了服务启动策略的主机配置文件不会禁用服务在将禁用了某些服务的 ESXi 主机用作引用主机的情况下创建一个主机配置文件,并将其应用到启用了这些服务的主机。主机配置文件应用过程不禁用目标 ESXi 主机上的服务。用户通过 vSphere Client 中的 [安全配置文件] 或 DCUI 中的 [故障排除选项] 在目标 ESXi 主机上启用 ESXShell 或 SSH 服务后,通常会出现这种情况。
1001.Vmware vSphere5.0网络连接服务器配置常见问题
网络连接, 配置, 服务器网络连接问题
将版本为 QLE3142 的 10 G QLogic 网卡与 nx_nic 驱动程序配合使用会导致服务器在 gPXE 引导期间停止运行 如果将版本为 QLE3142 的 10 G QLogic 网卡与 nx_nic 驱动程序配合使用,以进行 gPXE 引导进入 ESXi 无状态引导配置,则 ESXi 服务器会停止运行且无法引导。
5. 单击[选项]。
6. 单击[停止]并单击[确定]。
如果无法解析 vCenter Server 主机名,则 vSphere Web Client 不会加载 vCenter Server 清单
如果 vSphere Web Client 无法解析 vCenter Server 系统的主机名,并且 vCenter Server 使用 IP 地址向 vSphere Client 进行了注册,则 vSphere Web Client 无法加载清单树。
解决办法:无。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
虚拟机管理问题
早于 2.6.27 版本的 Linux 内核不报告处于关闭电源状态的每插槽内核数为 2
从ESXi 5.0 开始,多核虚拟CPU 支持允许处于关闭电源状态的每插槽内核数为2。
早于2.6.27 版本的Linux 内核仅正确报告处于打开电源状态的每插槽内核数为2。
例如,当您在 .vmx 文件中设置numvcpus = 6和cpuid.coresPerSocket = 3时,一些Linux 客户机操作系统可能无法报告任何物理标识信息。
Linux 内核 2.6.28 及更高版本会正确报告CPU 和内核拓扑。
解决办法:无
将内存热添加到使用 Linux 64 位或 Windows 7、32 位客户机操作系统的虚拟机时,无法将现有虚拟内存增加到 3 GB 以上
下列情况适用于将内存热添加到使用Linux 64 位或Windows 7 32 位客户机操作系统的虚拟机。
如果已打开电源的虚拟机的内存少于3 GB,则内存热添加量不能超过3 GB。
如果虚拟机内存为1 GB,则可以添加2 GB。
如果虚拟机内存为2 GB,则可以添加1 GB。
如果虚拟机的内存为3444 MB,则可以添加128 MB。
如果已打开电源的虚拟机的内存正好为3 GB,则无法热添加任何内存。
如果已打开电源的虚拟机的内存超过3 GB,则可以将虚拟机内存增加到虚拟机打开电源时初始内存大小的16 倍或增至硬件版本限制(以两者中较小者为准)。
硬件版本7 的限制是255 GB,硬件版本8 的限制是1011 GB。
如果在虚拟机电源打开时,内存从小于或等于3 GB 增长到大于3 GB,则Linux 64 位和32 位Windows 7 客户机操作系统会冻结。
此vSphere 限制可确保您不会在客户机操作系统中触发该错误。
解决办法:无。
在硬件版本 7 虚拟机上进行 CPU 热添加时出错
硬件版本8 虚拟机的多核虚拟CPU 功能支持虚拟CPU 热添加。
对于每个插槽的内核数大于1 的硬件版本7 虚拟机,当您在[虚拟机属性] 对话框中启用CPU 热添加并尝试热添加虚拟CPU 时,操作失败并显示以下错误消息:该虚拟机不支持CPU 热插拔(CPU hot plug not supported for this virtual machine)。
解决办法:要在硬件版本7 虚拟机上使用CPU 热添加功能,请关闭虚拟机电源并将每个插槽的内核数设置为1。
为达到最佳效果,请使用硬件版本8 虚拟机。
同时创建大量虚拟机会导致文件操作失败
同时创建大量驻留在同一目录下的虚拟机时,存储系统变得不堪重负,导致一些文件操作失败。
会显示vim.fault.CannotAccessFile错误消息并且创建虚拟机操作失败。
解决办法:以更小的批量(例如64 个)创建其他虚拟机,或尝试在不同的数据存储中或同一数据存储的不同目录中创建虚拟机。
在通过 vMotion 进行迁移过程中,从 ESXi 主机直通到虚拟机的 USB 设备可能断开连接
如果USB 设备从ESXi 主机直通到虚拟机并且该设备配置为在通过vMotion 进行迁移过程中仍保持连接,则该设备可能会在vMotion 操作过程中断开连接。
如果DRS 触发迁移,该设备也会断开连接。
当设备断开连接时,它们会恢复至主机,不再连接到虚拟机。
迁移连接了多个USB 设备的虚拟机时,会更频繁地发生此问题,但连接了一个或少数设备时,只偶尔发生此问题。
解决办法:将虚拟机迁移回与USB 设备物理连接的ESXI 主机,并将设备重新连接到虚拟机。
受支持硬件问题
IBM x3550 M2 的 [启动时强制支持旧版视频] 必须禁用
IBM x3550 M2 有一个称为Force Legacy Video on Boot 的固件选项,当从统一可扩展固件接口(UEFI) 引导时,该选项启用旧版INT10h 视频支持。
此选项与ESXi 5.0 不兼容,因而必须禁用。
解决办法:从UEFI 引导IBM x3550 M2 时,按F1进入固件设置,然后选择[系统设置] > [旧版支持] > [启动时强制支持旧版视频],并单击[禁用]。