MTV Produkttraining
PS 4000 roof variants
Roof plate for cable entry
Purpose-designed for cables with a small crosssection. The top module serves as an additional useful space for power distribution
MTV Produkttraining
PS 4000 frame
Flexibility
18 tapped holes per corner piece guarantee rapid fastening of angular baying brackets, cable clamp rails etc. With the threaded block, any square PS hole can be converted into a tapped hole in next to no time
MTV Produkttraining
PS 4000 frame
All-round, uninhibited access to the enclosure and optimum clearance openings. Additional welding in the corners ensures optimum stability. Maximum useful mounting space, thanks to 9-fold profiling.
MTV Produkttraining
PS 4000 side panel variants
Variants
The alternative when fast removal and re-installation of the side panels is often required. Simply slot into position and lock with the key. Side door for convenient access. Mounting frame for wallmounted cooling units.
MTV Produkttraining
PS 4000 standard door
Handling
For machining the door, the tubular door frame can be removed and re-installed in next to no time. The double-bit lock insert may be exchanged for numerous individual lock inserts and the Ergoform S handle.
MTV Produkttraining
PS 4000 side panel
Handling
Simply slot the side panel (rear panel) into position and secure. Simply clip the mounting parts into position and secure the side or rear panel with six screws. Roof fixing is possible with the eyebolt - no need for additional mounting parts.
MTV Produkttraining
PS 4000 roof ventilation
Passive ventilation of the enclosure by means of:
Spacers to raise the roof plate. The vented roof plate is a simple method of climate control which uses the enclosure’s natural convection to optimum effect.
MTV Produkttraining
PS 4000 side panel variants
Shielding / cable entry
Divider panel to shield individual enclosure cells from one another. Marshalling plate allows heavy rack connectors to be used safely. Connector cover to protect the rack connectors.
MTV Produkttraining
PS 4000 bayability
Transportation
Combination angles instead of eyebolts provide an additional connection and ensure optimum load distribution on the corner points of the individual enclosures. The transport plinth is a special solution for heavy enclosure suites up to a length of 5 m.
MTV Produkttraining
PS 4000 bayability
Baying variants
Baying kit for an invisible, stable standard connection Baying brackets for the connection of pre-assembled doors and rear panels when using divider panels quick-fit baying clamps facilitate fast, on-site assembly
MTV Produkttraining
PS 4000 roof variants
Accessories
Combination angles are used instead of eyebolts for transporting heavy enclosure suites by crane.
MTV Produkttraining
MTV Produkttraining
PS 4000 frame
Stability
The 9-fold profiled special extrusion forms the basis for PS 4000 perfect enclosure systems. Fast assembly and maximum useful space are the outstanding user benefits of this patented profile frame.
MTV Produkttraining
PS 4000 door installation
Earth straps
are available in the correct length in all standard crosssections. The wiபைடு நூலகம்ing plan lectern, wiring plan pocket and disk box may be used to store documentation.
MTV Produkttraining
PS 4000 door variants
Glazed doors
The standard doors are quickly and easily replaced with glazed doors. Glazed doors may be fitted instead of the rear panel.
MTV Produkttraining
PS 4000 door installation
External door installation
Viewing windows reliably protect built-in control components from ambient influences and unauthorised access. The operating panel with additional viewing window guards against unauthorised access. The keyboard tray and monitor frame facilitate conversion into a PC enclosure
MTV Produkttraining
PS 4000 door variants
Partial doors
By using partial doors with or without a viewing window, 600 mm wide enclosures are easily divided into individual functional units. A PC enclosure may be integrated into an existing suite of enclosures.
PS 4000 standard base
Thanks to the holes provided as standard, floor fixing can also be achieved without an enclosure plinth. The 25 mm pitch pattern of holes offers individual mounting points for support rails and cable clamp rails.
MTV Produkttraining
PS 4000 standard door
Technical details
The door opening angle of 130°ensures optimum access. The door hinge is easily swapped to the opposite side. The ground clearance of 25mm guarantees easy opening of the door, even on uneven surfaces.
MTV Produkttraining
PS 4000 door installation
The security lock ensures that the doors cannot be opened whilst the master switch is active. The door stay prevents unintentional slamming of the open enclosure door.
PS 4000 frame
The enclosure with endless possibilities
MTV Produkttraining
PS 4000
Optimum static design with a minimal profile cross-section. Cost reduction via standardised mass production. Quality, as verified by internationally recognised approvals and test certificates. Available with one or more doors.
MTV Produkttraining
PS 4000 door installation
Cable conduit / cable conduit holder
These facilitate secure cable routing, even on moving parts. Door rails are an ideal aid for installation assembly on the inside of the door.