Hard disk replace and sync(换刀片服务器硬盘步骤)
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
1.Replace hard disk
1)Restart the system , when we see “MPT SAS BIOS”, chose “CTRL+C”.
2)Chose “SAS1064E/C1064E”, press “Enter”.
3)Chose“RAID PROPERTIES”,press “Enter”.
4)We can see which hard disk is broken, i f it's broken , the “PredFail”is “YES”.
5)Find out the broken hard disk as we see in the “View Array”, and replace it.
2.Sync.
1)Restart the system , when we see “MPT SAS BIOS”, chose “CTRL+C”.
2)Chose “SAS1064E/C1064E”, press “Enter”.
3)Chose “RAID PROPERTIES”,p ress “Enter ”.
4)Chose “View Existing Array”,p ress “Enter” .
5)Chose “Manage Array“press “Enter”.
6)Chose “Delete Array“ to delete the old raid.
7)P ress “Space” in “RAID Disk“ [No],c hose “M”,it will change to be [Yes].The second hard
disk need the same process.
8)Chose “Synchronize Array“strating sync.
9)Save and exit,restart the blade.(Sync need about 2 hours)