1.Replace hard disk

1)Restart the system , when we see “MPT SAS BIOS”, chose “CTRL+C”.

2)Chose “SAS1064E/C1064E”, press “Enter”.

3)Chose“RAID PROPERTIES”,press “Enter”.

4)We can see which hard disk is broken, i f it's broken , the “PredFail”is “YES”.

5)Find out the broken hard disk as we see in the “View Array”, and replace it.

2.Sync.

1)Restart the system , when we see “MPT SAS BIOS”, chose “CTRL+C”.

2)Chose “SAS1064E/C1064E”, press “Enter”.

3)Chose “RAID PROPERTIES”,p ress “Enter ”.

4)Chose “View Existing Array”,p ress “Enter” .

5)Chose “Manage Array“press “Enter”.

6)Chose “Delete Array“ to delete the old raid.

7)P ress “Space” in “RAID Disk“ [No],c hose “M”,it will change to be [Yes].The second hard

disk need the same process.

8)Chose “Synchronize Array“strating sync.

9)Save and exit,restart the blade.(Sync need about 2 hours)