model_106臭氧浓度分析仪

合集下载

2B臭氧分析仪106-L 使用说明书操作手册 2B科技设计的Model 106-L型号臭氧分析仪采用254nm紫外吸收法技术

2B臭氧分析仪106-L 使用说明书操作手册 2B科技设计的Model 106-L型号臭氧分析仪采用254nm紫外吸收法技术

Model 106 臭氧分析仪手册Rev. D 12目录鉴别记录..............................................................................................3 打印记录................................................................................3 担保申明................................................................................4 警告......................................................................................6 臭氧分析仪引言.......................................................................7 技术规格................................................................................9 操作......................................................................................9 菜单.....................................................................................12 维护/故障诊断........................................................................20 校准.....................................................................................22 部件表..................................................................................28 服务记录...............................................................................28 附录A :USB 安装...................................................................29 附录B :使用USB 连接. (32)深圳市深国安电子科技有限公司地址:广东省深圳市龙华新区牛栏前大厦A1509网址:www.singoan.com www.singoan.com.cn www.shenguoan.com蒋小姐:134 2876 2631 电话:86 755-852589003鉴别记录请记录下列信息用做将来参考:产品序列号:____________________________________ 质保日期: ____________________________________(自收货之日起有效)打印记录新版本是仪器操作指南的完整修订本,合并了先前所有该仪器的更新彩页及补充说明。

高浓度紫外臭氧分析仪安全操作及保养规程

高浓度紫外臭氧分析仪安全操作及保养规程

高浓度紫外臭氧分析仪安全操作及保养规程1. 引言高浓度紫外臭氧分析仪是一种用于测量空气中臭氧浓度的专业仪器。

为了正确使用和保养该仪器,确保操作人员的安全以及仪器的正常运行,本文档提供了高浓度紫外臭氧分析仪的安全操作规程和保养规程。

2. 安全操作规程2.1 仪器准备在进行任何操作之前,请确保仪器的正常工作状态,包括检查供电连接是否稳定,仪器表面是否干净等。

2.2 穿戴个人防护装备在操作高浓度紫外臭氧分析仪时,务必穿戴以下个人防护装备:•护目镜:保护眼睛免受臭氧辐射的伤害。

•手套:避免直接接触仪器或样品,防止可能的化学物质伤害。

2.3 安全操作步骤1.将高浓度紫外臭氧分析仪放置在平稳的工作台上,确保仪器稳定。

2.打开仪器供电开关,等待仪器启动。

3.根据具体样品和测试要求,设置仪器参数。

4.将样品放入样品槽内,紧闭样品槽盖。

5.启动测试程序,开始臭氧浓度测试。

6.在测试过程中,严禁将手指或其他物体伸入样品槽内,以免发生意外。

7.测试完毕后,关闭仪器供电开关,等待仪器停止运行。

8.移除样品,清洁样品槽和仪器表面,并及时关好仪器的盖子。

2.4 急救措施如果在操作高浓度紫外臭氧分析仪的过程中发生意外伤害,应立即采取以下急救措施:•眼部暴露于臭氧辐射下:立即用大量清洁水冲洗眼睛,并尽快就医。

•皮肤接触到化学物质:立即用清水冲洗受伤部位,并寻求医疗救助。

•不慎吸入臭氧:及时转移到通风良好的地方,并请医生提供帮助。

3. 仪器保养规程3.1 清洁定期清洁高浓度紫外臭氧分析仪是保持其正常运行的重要步骤。

以下是清洁仪器的建议步骤:1.使用干净、柔软的布擦拭仪器表面。

2.对于较难清洁的区域,可以使用棉签或软刷进行清洁。

3.避免使用含酸、碱或溶剂的清洁剂,以免损坏仪器表面。

3.2 仪器存放在不使用高浓度紫外臭氧分析仪时,应将其储存在干燥、阴凉的地方,避免阳光直射和高温环境。

同时,应注意以下事项:1.仪器存放时,应避免与腐蚀性、易燃性和有毒物质接触。

臭氧检测仪操作方法

臭氧检测仪操作方法

臭氧检测仪操作方法臭氧检测仪是一种用于测量、检测和监测空气中臭氧浓度的仪器。

下面我将为您详细介绍臭氧检测仪的操作方法。

步骤一:检查仪器和测试环境在操作臭氧检测仪之前,首先需要检查仪器是否完好无损,并符合使用要求。

同时,还需要检查测试环境,确保没有其他物质可能对测试结果产生干扰。

步骤二:打开仪器按下仪器上的开关按钮,打开臭氧检测仪。

一般来说,仪器会进行自检程序,显示自检结果,确保仪器正常工作。

在自检程序完成后,屏幕上将显示出当前的臭氧浓度。

步骤三:选择测量模式根据实际需求,选择合适的测量模式。

一般常见的有实时测量模式、记录测量模式和峰值测量模式。

实时测量模式能够实时显示当前的臭氧浓度;记录测量模式可以将数据记录下来供后续分析;峰值测量模式可以显示出测试过程中的最高臭氧浓度。

步骤四:校准仪器臭氧检测仪需要定期进行校准,以确保测试结果的准确性。

校准通常需要使用标准气体,按照仪器说明书上的方法进行操作。

步骤五:开始测量选择好测量模式并完成校准后,可以开始进行测量。

将仪器置于待测空气中,保证仪器与环境充分接触。

在测量过程中,仪器会实时显示臭氧浓度的变化。

步骤六:记录数据在测量过程中,可以根据需要记录数据。

记录数据的方式可以是手动记下来,也可以通过仪器上的数据存储功能将数据保存下来。

步骤七:结束测量当完成测量后,按下仪器上的停止按钮,结束测量。

此时,仪器将停止测量并显示最终的测量结果。

步骤八:关闭仪器在结束测量后,按下仪器上的关闭按钮,彻底关闭仪器电源。

这样可以保证仪器的寿命,并减少不必要的能源浪费。

需要注意的是,不同品牌、型号的臭氧检测仪可能存在一些细微差异,在操作之前最好先阅读仪器使用说明书,并按照说明书上的指导进行操作。

总结一下,臭氧检测仪操作步骤包括检查仪器和测试环境、打开仪器、选择测量模式、校准仪器、开始测量、记录数据、结束测量以及关闭仪器。

通过正确操作臭氧检测仪,我们可以准确地测量和监测空气中的臭氧浓度,为保护环境和人类健康提供有力的支持。

臭氧检测仪的使用方法

臭氧检测仪的使用方法

臭氧检测仪就是采用紫外线吸收法的原理,用稳定的紫外灯光源产生紫外线,用光波过滤器过滤掉其它波长紫外光,只允许波长253.7nm通过。

经过样品光电传感器,再经过臭氧吸收池后,到达采样光电传感器。

那么臭氧检测仪的检测方法都有哪些呢?
检测臭氧浓度的方法大致可分为两种:仪表法和化学分析法。

仪表法检测臭氧的优点在于灵敏度高,重复性好,对操作者水平要求也不高,是一种较好的方法,但是因为此类仪表原来一般价格昂贵,不易普及使用。

化学分析法中常用的是碘化钾法,硼酸碘化钾吸光光度法和靛蓝二磺酸钠分光光度法。

前两种方法因对臭氧的专属性不好或稳定性较差,在现场使用中均受到某些限制,而靛蓝二磺酸钠分光光度法因灵敏度高,对臭氧的专用性强,无需标准即可用于O3的定量测量,所以在1996年国家颁布的空气质量标准GB3095-1996中,用该法代替原标准中的硼酸碘化法作为化学检查O3的标准。

仪表检测臭氧浓度的原理是采用化学发光法、紫外线吸收法和电化学法三种。

因化学发光法须配用乙烯气瓶,乙烯又是可燃物,既危险又不方便,所以近年来常用的是紫外线吸收法和电化学法两种。

紫外线吸收法的原理是基于O3对波长254nm的紫外光的吸收,根据比尔一朗的定律可以算出O3的浓度,这种方法结构简单、灵敏度高、响应快,在臭氧高浓度范围内(0-10000ppm)具有良好的线性,且零点漂移和量程漂移都很小。

电化学法是被测臭氧气体以扩散方式或泵吸方式和仪表接触,并发生反应。

输出稳定的电信号。

气体浓度值可以稳定地用数据显示在显示屏上,此方法检测臭氧简单方便,随拿随测。

臭氧检测仪的原理和使用方法

臭氧检测仪的原理和使用方法

臭氧检测仪的原理和使用方法
◆使用方法(以环伟HW-JC为例)
1.开启中央空调;确认风管有风吹入洁净空
间;
2.给臭氧发生器通入冷却水;确定臭氧出气口已用管道导入中央空调送风或回风管道;然后开启臭氧发生器;正常开机时间一般为1小时。

3.臭氧浓度检测仪的开机方法是:长按⊙健(约5秒钟);有显示后放开;暖机时间为120秒;过了暖机时间就可以检测空气中的臭氧浓度;臭氧浓度以数字形式显示在检测仪的显示板上。

臭氧浓度超过20ppm时臭氧检测仪会报警并闪光;最大量程是100ppm
4.一般建议按时间段进入洁净区检测臭氧浓度;臭氧发生器工作30分钟后检测一次;臭氧发生器工作60分钟后检测一次;如有必要则90分钟及120分钟再各检测一次;一般臭氧发生器工作30分钟后就能马上检测到臭氧浓度;工常工作时间为1小时;如果检测不到臭氧浓度或偏低则要检测臭氧是否有导入管道内或者臭氧是否有漏泄;如果臭氧有漏泄则会导致臭氧浓度偏低;如果检测空气中臭氧浓度过高则控制好灭菌的时间即可。

◆检测臭氧浓度的方法
臭氧氧化可变色试剂浸渍在载体上作为反应剂封装内径的玻璃管内做成检测管,使用时将检测管两端切断,把抽气器接到检测管出气端吸取定量臭氧气体,臭氧浓度与检测管内反应剂柱变色长度成正比,通过刻度值读取浓度值。

臭氧检测仪较早应用的是电位测量,即利用氧化还原复合电极通过检测水中氧化还原电位变化而对应计算出溶解臭氧浓度。

专用装置内部分析运算处理直接数字显示,只使用Redox电。

臭氧测定仪原理

臭氧测定仪原理

臭氧测定仪原理臭氧测定仪原理1、仪器工作原理:臭氧测定仪主要是根据生物膜体外光谱法来测定气体臭氧浓度,它采用了量子电子发射原理,它将光子发射出去,发生反射,然后对反射光进行扫描和检测,根据这种发射-反射的规律,将反射的光波的强度和频率的大小,相应的映射到测定臭氧浓度的参数上,以取得精准的臭氧浓度测量结果。

2、检测原理:利用臭氧对波长较短的UVC光辐射有抑制作用,即可以根据UVC光在发射光和反射光波长较短的波长处的增殖(发射-反射)大小,来推断空气中的臭氧浓度。

另外,臭氧的发射-反射特性受温度、湿度、压力、气溶胶等元素的影响,仪器可以通过预先设定的校准参数,把这些影响因素进行控制和补偿,从而取得准确的臭氧浓度。

3、主要技术参数:(1)臭氧测量范围:0-100ppm;(2)臭氧测量精度:≤0.2ppm;(3)检测距离:1.5m-10m;(4)检测时间:≤2s;(5)环境温度:-20℃~45℃;(6)工作电压:220V/50Hz;(7)功耗:<13W;(8)数据接口:RS232/RS485。

4、主要特点:(1)精确度高:通过自动控制显示精度,保证臭氧浓度的准确性;(2)安全可靠:采用彩色LED等安全特性,保障在长时间的可以正常使用;(3)操作简便:采用机械传动技术,操作简单,只需取出仪器,将参数调好,就可以测量;(4)独立实验性能好:采用独立设计,结构合理,测量范围、量程等可根据环境要求自行调节,进行独立实验;(5)灵活可靠:数据接口多,可以连接电脑或者笔记本,灵活实现气体臭氧浓度的实时监测和记录;(6)高性价比:该仪器具有较高的性价比,机型多样,型号可以根据不同的客户要求进行定制。

综上所述,臭氧测定仪采用了优质的传感器和控制系统,结构合理、安全可靠、使用简便,精确稳定,可满足客户对臭氧浓度的检测和监测要求,具有一定的应用价值。

2B臭氧分析仪106-L 使用说明书操作手册 2B科技设计的Model 106-L型号臭氧分析仪采用254nm紫外吸收法技术

2B臭氧分析仪106-L 使用说明书操作手册 2B科技设计的Model 106-L型号臭氧分析仪采用254nm紫外吸收法技术

Model 106 臭氧分析仪手册Rev. D 12目录鉴别记录..............................................................................................3 打印记录................................................................................3 担保申明................................................................................4 警告......................................................................................6 臭氧分析仪引言.......................................................................7 技术规格................................................................................9 操作......................................................................................9 菜单.....................................................................................12 维护/故障诊断........................................................................20 校准.....................................................................................22 部件表..................................................................................28 服务记录...............................................................................28 附录A :USB 安装...................................................................29 附录B :使用USB 连接. (32)深圳市深国安电子科技有限公司地址:广东省深圳市龙华新区牛栏前大厦A1509网址:www.singoan.com www.singoan.com.cn www.shenguoan.com蒋小姐:134 2876 2631 电话:86 755-852589003鉴别记录请记录下列信息用做将来参考:产品序列号:____________________________________ 质保日期: ____________________________________(自收货之日起有效)打印记录新版本是仪器操作指南的完整修订本,合并了先前所有该仪器的更新彩页及补充说明。

臭氧浓度仪使用说明书

臭氧浓度仪使用说明书

臭氧浓度仪使用说明书
浓度仪使用可调旋钮及按钮有:流量计及4个按钮:
流量计在浓度仪左侧,可通过旋钮调节流量;
4个按钮在浓度仪面板上
按键从左往右依次是:1、电源(此按钮无用)2、复位(即校验)
3、初始化
4、单位
一、在开机、初始化或者复位(即校验)前,先调整浓度仪的压力与流量将与浓度仪相连接的阀门略微开启;按浓度仪面板上单位按钮,切换到指示灯g/m3和%wt全亮ppm不亮时看读数是否在3.00左右(3.20以下为宜),若未达到说明压力太大,仍需调节阀门和浓度仪自带的流量计(流量计需工作在200到400 之间)。

当调整完后,通氧气(或者空气)20~30分钟。

二、在一步骤完成后,开始操作浓度仪面板上的按钮:
复位(即校验)此按钮为在浓度仪数值发生偏差时用于数值的校正,按下此键后需等待显示的时间结束(15分钟)后方可打开臭氧发生器。

初始化按钮是为了当仪器出现零部件更换或者重启浓度仪之用;一般浓度仪未出现异常可不需按此按钮;按下此键后需等待显示的时间(5分钟)结束后方可打开臭氧发生器。

单位按钮就是为了臭氧浓度各个单位的切换:第1个指示灯为电源指示灯,一直亮着;初始为g/m3即指示灯从上往下第1和3个灯亮;若第1和4灯亮,单位是%wt;第1和2个灯亮,单位是ppm。

(其他指示灯和数值可不管,只是用于调试时用)。

注意:若出现断电后供电,请完成步骤一后按下初始化按钮,直至等待时间结束(15分钟)后方可打开臭氧发生器。

2013-2017年太原市臭氧浓度变化特征

2013-2017年太原市臭氧浓度变化特征

h j h x .r c e e s .a c .cn 环㊀境㊀化㊀学ENVIRONMENTALCHEMISTRY第38卷第8期2019年8月Vol.38,No.8August2019㊀2018年12月16日收稿(Received:December16,2018).㊀∗通讯联系人,Tel:15536643309,E⁃mail:liyongqi103@126.comCorrespondingauthor,Tel:15536643309,E⁃mail:liyongqi103@126.com2018121602DOI:10.7524/j.issn.0254⁃6108.2018121602冯新宇.2013 2017年太原市臭氧浓度变化特征[J].环境化学,2019,38(8):1899⁃1905.FENGXinyu.VariationcharacteristicsofozoneconcentrationinTaiyuanfrom2013to2017[J].EnvironmentalChemistry,2019,38(8):1899⁃1905.2013—2017年太原市臭氧浓度变化特征冯新宇∗(太原市环境监测中心站,太原,030002)摘㊀要㊀利用2013 2017年太原市近地面O3的连续观测资料以及气象数据,分析了太原市O3浓度的变化特征及其与气象要素的关系.结果表明,太原市2013 2017年O3浓度整体呈上升的趋势,特别是2017年,O3⁃8h浓度超标天数达到66d,O3污染形势严峻.O3浓度的月变化峰值出现在6月份,日变化特征呈现单峰型分布,5 7时浓度较低,15 16时出现峰值.除上兰背景点外,太原市不同监测点位O3浓度变化总体表现为城市周边点位高于城市中心.气象因素分析表明,O3与NO2㊁PM2.5及相对湿度呈负相关性,而与气温㊁风速呈正相关性.当风向为南风或西南方风时,O3浓度较高,说明太原市O3浓度升高可能与区域污染输送有关.关键词㊀臭氧,变化特征,光化学反应,太原,气象参数.VariationcharacteristicsofozoneconcentrationinTaiyuanfrom2013to2017FENGXinyu∗(EnvironmentMonitoringCenterStationofTaiyuan,Taiyuan,030002,China)Abstract:Thecharacteristicsofsurfaceozoneconcentrationanditsrelationshipwithmeteorologywereanalyzedbycontinuousobservationfrom2013to2017inurbansiteofTaiyuan.Theresultsshowedthattheannualaveragedconcentrationofozonewasincreasingfrom2013to2017,theoverpolluteddaysofozonewere66dandthesituationofozonepollutioninTaiyuanbecameworse.OzoneconcentrationreacheditspeakinJuneinayear,thediurnaldistributionofozonepresentedaclearunimodalwithitspeakappearingat15:00or16:00andtroughat05:00or07:00.Forthespatialdistributionofozone,theconcentrationwaslowerincentralsitesthansuburbssitesexceptforShanglansite.Theresearchshowedthattheozoneconcentrationwaspositivelycorrelatedwithtemperatureandwindspeed,whilenegativelycorrelatedwithNO2,PM2.5andrelativehumidity.Thehigherozoneconcentrationwasfoundundersouthwestandsouthernwinds,whichindicatedthatozonemayberelatedtoregionalpollutiontransport.Keywords:ozone,variationcharacteristics,photochemicalreaction,Taiyuan,meteorologicalfactor.臭氧是大气中的一种微量气体,正常存在于平流层中的臭氧能够吸收太阳辐射出的紫外线而保护地球[1];近地面大气中的臭氧主要是由人类活动排放的氮氧化物(NOx)和挥发性有机物(VOCs)等污染物在大气中经过光化学反应所产生[2],它能对地球上的生命包括人类㊁动物㊁植物等产生危害.近年来,O3浓度在我国甚至全球都呈现上升趋势,特别是我国一些经济快速增长㊁人口密集的长三角㊁珠三角以及京津冀地区,O3污染问题日益突出[3⁃5].目前,关于这方面的研究已经有许多相关报道[6⁃17],吴锴等[8]h jh x .r c e e s .a c .c n 1900㊀环㊀㊀境㊀㊀化㊀㊀学38卷对成都市2014 2016年6个国控监测站和气象观测数据进行了研究分析,揭示了成都市O3变化的规律及其与气象因素的关系;段晓瞳等[11]根据2015年全国189个城市的近地面臭氧浓度数据,从不同时空㊁地形特征㊁温度等方面详细研究了中国近地面臭氧浓度的变化特征;Sicard等[14]比较了欧洲地中海区域214个城郊区域近地面O3浓度的变化趋势,揭示了城市区域O3存在上升趋势,而且指出气候变化对城市臭氧污染具有很强的影响性;Seo等[15]研究了韩国区域气象因子对近地面O3时空变化的影响.太原市作为山西省省会,人口密集,工业㊁交通业发展迅速,机动车保有量持续增加,容易形成臭氧污染.因此,针对大气O3浓度进行连续监测,开展分析和研究工作具有十分重要的意义.目前,关于太原市臭氧污染特征分析相关文献较少,且研究时间跨度较小,不能反映长时间序列的O3浓度变化特征及影响因素.本文利用2013 2017年太原市环境监测中心站自动监测网络监测的O3数据,系统分析了太原市O3浓度的变化特征及其气象影响因素,以期为太原市大气污染防治提供理论基础和科学依据.1㊀实验部分(Experimentalsection)1.1㊀监测点位分布太原市位于东经111ʎ30ᶄ 113ʎ09ᶄE,北纬37ʎ27ᶄ 38ʎ25ᶄN,西㊁北㊁东三面环山,平均海拔约800m,中㊁南部为河谷平原,整个地形北高南低,属温带季风性气候,室外近地面风速年均值为0.3m㊃s-1,大气压年均920hPa,空气湿度年均49%[18].目前,太原市空气质量监测点主要包括9个国控自动监测点,点位设置如图1所示,从图1可知,9个国控点基本覆盖了太原市主要的建成区(巨轮点位由于其它原因于2018年9月开始重新监测,本文监测时间段不包括该点位),其中上兰点位为清洁对照点,各点位布设均符合国家‘环境空气质量监测点位布设技术规范(试行)HJ664 2013“的要求.图1㊀太原市9个监测点位的位置分布Fig.1㊀Locationof9airqualitymonitoringsitesinTaiyuan1.2㊀监测仪器各监测点采样口距地面高度及样品分析方法均依据国家相关标准进行,O3监测仪器全部使用美国热电公司Modeli系列O3自动分析仪,仪器精度1.0μg㊃L-1,最低检测限0.5μg㊃L-1.监测指标参考中国环境空气质量标准统计臭氧小时平均浓度(O31h)㊁臭氧日最大8h平均浓度(O3⁃8h)㊁O3⁃8h百分位浓度(臭氧月㊁年浓度),其它监测项目均使用国控点位热电公司设备数据,观测期间,严格按照环境空气质量自动监测技术规范(HJ_T193 2005)的要求对系统设备进行日常维护和校准,保证监测数据准确有效.本研究选取太原市空气质量自动监测系统2013 2017年6项污染物的连续监测数据,并按照GB3095 2012的相关规定进行数据进行有效性检验.h jh x .r c e e s .a c .c n ㊀8期冯新宇:2013 2017年太原市臭氧浓度变化特征1901㊀2㊀结果与讨论(Resultsanddiscussion)2.1㊀2013 2017年太原市O3浓度总体变化情况图2是太原市与74城市及京津冀11地市O3⁃8h年百分位浓度比较情况,从图2中可知,2013 2017年,全国74个空气质量重点城市及京津冀11个地市环境空气中的O3浓度均呈逐年上升的趋势,在2017年之前,O3⁃8h年百分位浓度还在‘环境空气质量标准“GB3095 2012中规定的二级标准(160μg㊃m-3)以下,但在2017年O3⁃8h年百分位浓度有比较明显的上升.太原市环境空气中O3污染物浓度变化趋势与74城市和京津冀11地市基本一致(除了2013年),总体上污染程度低于74城市和京津冀11地市平均水平,但近年来上升趋势比较明显,特别是2017年,O3⁃8h年百分位浓度达到189μg㊃m-3,超过国家二级标准(160μg㊃m-3)0.18倍,是74城市平均水平的0.12倍,O3污染情况日趋严重.(太原市以外其他城市的O3监测数据来自真气网,http://palm.zq12369.com)2.2㊀O3浓度年变化情况图3为不同年份太原市O3⁃8h月百分位浓度变化曲线,从图3中可知,O3⁃8h浓度年变化规律呈现倒 V 字形,春季(3 5月份)开始浓度逐渐升高,在春末夏初(6月份)浓度达到峰值(除了2014年㊁2017年峰值在7月)㊁夏季(6 8月份)浓度均保持在较高的水平;秋季(9 11月份)浓度逐渐下降;冬季(12月份 次年1月份)浓度基本维持在较低水平.O3在大气中发生复杂的光化学反应,包括自由基的生成㊁传递等[19⁃20],其反应速率与温度㊁湿度㊁太阳辐射等气象条件以及O3前体物浓度等众多因素有关.夏季太阳辐射强,气温较高,光化学反应较强,造成O3二次生成浓度较高;冬季光化学反应较弱,且在一定条件下,高浓度颗粒物导致气溶胶光学厚度增大,降低了O3光化学速率,两者共同作用导致冬季O3浓度最低.图2㊀不同年份太原市与其它城市O3⁃8h百分位浓度比较Fig.2㊀ThepercentileconcentrationvariationofO3⁃8hinTaiyuanandothercitiesindifferentyears图3㊀不同年份太原市O3⁃8h月百分位浓度变化曲线Fig.3㊀MonthlypercentileconcentrationofO3⁃8hinTaiyuanindifferentmonths2.3㊀O3浓度日变化情况图4为太原市2013 2015年年均及5 7月O3小时浓度的日变化曲线.从图4可知,整个曲线变化呈现单峰型分布,白天浓度明显高于夜间,这与许多城市和地区的日变化特征一致[21⁃22].早上8时开始受太阳辐射影响,O3浓度逐渐上升,午后太阳辐射最强,在光化学反应作用下,15时左右O3浓度达到最大值,之后随着太阳辐射强度的减弱又逐渐降低.就图4(a)全年平均浓度而言,O3浓度在早上5时至7时较低,其值处于17 22μg㊃m-3之间;峰值浓度主要集中在15时或16时,浓度值在68 108μg㊃m-3.对于图4(b)不同年份5 7月O3平均浓度,处于低值和峰值区的时间段与全年基本一致,但是各个时h j h x .r c e e s .a c .c n 1902㊀环㊀㊀境㊀㊀化㊀㊀学38卷段浓度明显上升,低值浓度集中在28 44μg㊃m-3,峰值浓度值集中在109 179μg㊃m-3,由于5 7月太原市气温相对较高,有利于光化学反应的进行,另外,外来O3及其前体物污染物输送也可能推高了本地的O3浓度[23].图4㊀不同年份太原市O3浓度日变化曲线(a)annualaveragevalue㊀(b)5 7MonthFig.4㊀DiurnalvariationofO3inTaiyuanindifferentyears2.4㊀超标情况分析根据2013年新标准及‘环境空气质量指数(AQI)技术规定“(HJ633 2012)分级方法,O3⁃8h大于160μg㊃m-3为超标日,本文对2013 2017年太原市O3⁃8h出现超标的情况进行了统计,结果见表1.从表1可知,2013 2017年O3⁃8h出现的超标天数分别为24㊁15㊁15㊁13㊁66d,2017年前各年超标天数及不同级别天数变化不大(2013除外),而2017年超标天数明显增加,特别是轻度和中度污染天数,O3污染水平有明显的增加趋势.根据相关监测数据,2017年O3作为首要污染物的天数达到了92d,对综合指数的贡献率为14.9%,是迄今为止太原市开展O3监测以来污染最为严重的一年.根据气象资料,2017年太原市日最高温度为30ħ及以上天数达77d,为2013年以来持续高温最多的一年,高温天气有利于光化学反应的进行,促使了O3超标天数的增加;另一方面,随着近年来环境空气治理力度的不断加大,大气中颗粒物浓度持续降低,也为光化学反应的进行提供了有利的条件,这些原因共同作用导致2017年O3浓度出现大幅度的增加.表1㊀不同年份O3⁃8h污染超标天数统计(天)Table1㊀StatisticalnumberofO3⁃8hexceedingthestandarddaysindifferentdays(d)污染级别Pollutionlever201320142015201620173级20141413544级411-115级----1共超标天数2415151366图5为不同年份太原市NO2㊁CO浓度年变化曲线,从图5中可知,NO2和CO浓度曲线具有相似的季节变化特征,冬季较高,夏季较低,这与O3⁃8h浓度变化(图3)情况正好相反,冬季大气层结构较为稳定,光化学反应弱,导致O3前体物NO2和CO浓度的积累;夏季光化学反应活跃,前体物大量转化为O3,导致其浓度增加.2.5㊀不同点位比较为了便于比较不同国控站点O3浓度变化情况,将各个点位的O3⁃8h百分位浓度按5年(2013 2017)以及2017年来进行统计,结果见图6.从图6可知,按5年统计,太原市区O3污染整体呈现市区周边点位相对较高,中心区域相对较低的特征.其中,污染最重的点位是金胜,该站点位于太原市西南方向城乡结合部,属传统的化工产业区,临近第一热电厂,因此来自本区域O3前体物VOCs及NOx排放量较h jh x .r c e e s .a c .c n㊀8期冯新宇:2013 2017年太原市臭氧浓度变化特征1903㊀大,继而通过光化学反应生成O3,这是O3浓度较高的一个原因.另外,在太原市南部及附近县市分布着大量的工业,受夏季偏南气流的影响,高浓度的O3及其前体物的外来输送老化也容易造成该点位O3浓度偏高.其次是南寨点位,该站点位于太原市东北方向城乡结合部,位于兴安化工场内,临近第二热电厂,植被情况在所有监测点位中最好,因此本区域的O3生成,加之城市中心区域的传输是该点位O3浓度较高的主要原因.2017年O3⁃8h百分位浓度总体偏高,城市南部点位的O3浓度上升较为明显,其中以小店点位上升最大.小店区是近年来太原市各城区中经济发展最为活跃的区域,O3的各种前体物排放量较大,因此本地污染物的排放及二次生成是O3主要来源.图7是不同点位2013 2017年超标天数总和比较图.从图7可看出,金胜和南寨的O3⁃8h超标天数明显高于其它点位,这与O3⁃8h百分位浓度变化情况是一致的.图5㊀不同年份太原市NO2㊁CO浓度月变化曲线Fig.5㊀MonthlyaverageconcentrationofNO2,COinTaiyuanindifferentmonths图6㊀不同点位O3⁃8h百分位值变化情况Fig.6㊀ThevariationofO3⁃8hpercentileindifferentobservationsites图7㊀不同点位O3⁃8h超标情况(2013 2017)Fig.7㊀ThenumberofO3⁃8hexceedingthestandarddaysindifferentobservationsites(2013 2017)2.6㊀O3与其它污染物及气象参数的关系为研究太原市O3浓度与污染物及气象参数的关系,将2017年全年太原市国控点位与O3相关的监测因子(不包括风向)小时值进行逐时平均,各监测因子对O3进行相关性分析,结果见表2.从表2中可知,除了CO㊁气压与O3相关性较弱外,其它各项浓度及参数都与O3有较强的相关性.其中,NO2㊁PM2.5及湿度与O3呈负相关性,气温㊁风速与O3呈正相关性.NO2是生成O3的重要前体物,是光化学反应的主要参与者;PM2.5浓度的大小会影响气溶胶光学厚度,进而影响O3光化学生成速率;高温㊁低湿是形成高浓度O3的重要气象条件;风速与O3浓度有较高的相关性,其对O3浓度的影响主要体现在两方面:一是抬高了大气边界层高度,垂直动量输送加强,进而促使对流层顶高浓度O3向地面传输;二是增强了O3的水平扩散作用,对稀释O3具有一定贡献[24].h j h x .r c e e s .a c .c n1904㊀环㊀㊀境㊀㊀化㊀㊀学38卷表2㊀O3与其它监测项目的相关性(R2)Table2㊀ThecorrelationcoefficientsofO3andothermonitoringobject(R2)监测项目MonitoringitemsNO2/(μg㊃m-3)CO/(mg㊃m-3)PM2.5/(μg㊃m-3)风速Windspeed/(m㊃s-1)气压Pressure/hpa气温Temperature/ħ湿度Humidity/%O31h/(μg㊃m-3)-0.796-0.383-0.7330.960-0.5370.947-0.939为进一步分析O3浓度变化及传输过程,结合研究时段O3整体变化情况,本文将太原市2016年和2017年太原市O3小时数据与风向数据按每10度一档进行归类统计,结果见图8.从图8可知,2016年和2017年O3浓度受风向影响规律基本一致,当太原市区风向为南风时,O3浓度相对最高,西南风时次之,当风向为北风或西北风时较低.由于太原市特殊的地理形势,来自北边的风会将污染物吹向地势较为开阔的南部地区,因此污染物扩散较为有利;当以南风为主时,来自周边县市高浓度的O3及逐渐老化的前体物会输送到太原市区,造成O3浓度值偏高.图8㊀O3浓度随风向变化分布图Fig.8㊀O3concentrationscorrespondingwithwinddirection3㊀结论(Conclusion)(1)太原市2013 2017年O3浓度整体呈上升的趋势,特别是2017年,O3浓度超标天数增加明显,O3⁃8h百分位浓度达到189μg㊃m-3,超过国家二级标准(160μg㊃m-3)0.18倍,是74城市平均水平的0.12倍,O3污染情况日益严重.(2)太原市每年6月左右O3浓度达到一年中的峰值,O3浓度日变化在早上5 7时浓度较低,15 16时出现小时浓度峰值.不同点位O3浓度变化呈现城市周边点位高于城市中心(背景点上兰除外)的规律,这与太原市产业分布特征及城市发展规划有关.(3)相关性分析表明,O3与NO2㊁PM2.5及湿度呈负相关性,气温㊁风速与O3呈正相关性.当风向为南风或西南方风时,O3浓度较高,说明太原市O3浓度升高除了本地生成外,还与南部外来传输有关.参考文献(References)[1]㊀黄丽,段书音,朱佳城,等.郑州市2015 2016年臭氧污染特征分析[J].郑州大学学报(医学版),2018,53(1):64⁃67.HUANGL,DUANSY,ZHUJC,etal.CharacteristicsanalysisofozonepollutioninZhengzhouCityin2015⁃2016[J].JournalofZhengzhouUniversity(MedicalSciences),2018,53(1):64⁃67(inChinese).[2]㊀齐兵,牛彧文,杜荣光,等.杭州市近地面大气臭氧浓度变化特征分析[J].中国环境科学,2017,37(2):443⁃451.QIB,NIUYW,DURG,etal.CharacteristicsofsurfaceozoneconcentrationinurbansiteofHangzhou[J].ChinaEnvironmentalScience,2017,37(2):443⁃451(inChinese).[3]㊀姚青,韩素芹,蔡子颖,等.2012年夏季天津城区BTEX污染特征与臭氧潜势分析[J].中国环境科学,2013,33(5):793⁃798.YAOQ,HANSQ,CAIZY,etal.ThediurnalvariationandozoneproductionpotentialofBTEXinTianjininthesummerof2012[J].h j h x .r c e e s .a c .c n ㊀8期冯新宇:2013 2017年太原市臭氧浓度变化特征1905㊀ChinaEnvironmentalScience,2013,33(5):793⁃798(inChinese).[4]㊀易睿,王亚林,张殷俊,等.长江三角洲地区城市臭氧污染特征与影响因素分析[J].环境科学学报,2015,35(8):2370⁃2377.YIR,WANGYL,ZHANGYJ,etal.PollutioncharacteristicsandinfluencefactorsofozoneinYangtzeRiverDelta[J].ActaScientiaeCircumstantiae,2015,35(8):2370⁃2377(inChinese).[5]㊀ZHANGYN,XIANGYR,CHANLY,etal.ProcuringtheregionalurbanizationandindustrializationeffectonozonepollutioninPearlRiverDeltaofGuangdong,China[J].AtmosphericEnvironment,2011,45(28):4898⁃4906.[6]㊀黄俊,廖碧婷,吴兑,等.广州近地面臭氧浓度特征及气象影响分析[J].环境科学学报,2018,38(1):23⁃31.HUANGJ,LIAOBT,WUD,etal.Guangzhougroundlevelozoneconcentrationcharacteristicsandassociatedmeteorologicalfactors[J].ActaScientiaeCircumstantiae,2018,38(1):23⁃31(inChinese).[7]㊀程念亮,李云婷,张大伟,等.2004⁃2015年北京市清洁点臭氧浓度变化特征[J].环境科学,2016,37(8):2847⁃2854.CHENGNL,LIYT,ZHANGDS,etal.CharacteristicsofozonebackgroundconcentrationinBeijingfrom2004to2015[J].EnvironmentalScience,2016,37(8):2847⁃2854(inChinese).[8]㊀吴锴,康平,王占山,等.成都市臭氧污染特征及气象成因研究[J].环境科学学报,2017,37(11):4241⁃4252.WUK,KANGP,WANGZS,etal.OzonetemporalvariationanditsmeteorologicalfactorsoverChengduCity[J].ActaScientiaeCircumstantiae,2017,37(11):4241⁃4252(inChinese).[9]㊀马志强,王跃思,张小玲,等.北京城区与下游地区臭氧对比研究[J].环境科学,2011,32(4):924⁃929.MAZQ,WANGYS,ZHANGXL,etal.ComparisonofozonebetweenBeijinganddownstreamarea[J].EnvironmentalScience,2011,32(4):924⁃929(inChinese).[10]㊀刘湾湾,刘琼,陈勇航,等.上海地区对流层低层臭氧及硫酸盐气溶胶时空分布特征研究[J].环境科学学报,2018,38(6):2214⁃2222.LIUWW,LIUQ,CHENYH,etal.ThetemporalandspatialdistributioncharacteristicsoflowertroposphericozoneandsulfateaerosolsinShanghai[J].ActaScientiaeCircumstantiae,2018,38(6):2214⁃2222(inChinese).[11]㊀段晓瞳,曹念文,王潇,等.2015年中国近地面臭氧浓度特征分析[J].环境科学,2017,38(12):4976⁃4982.DUANXT,CAONW,WANGX,etal.CharacteristicsanalysisofthesurfaceozoneconcentrationofChinain2015[J].EnvironmentalScience,2017,38(12):4976⁃4982(inChinese).[12]㊀岳婷婷,柴发合,张新民,等.天津武清地区夏季臭氧光化学研究[J].环境科学研究,2009,22(1):23⁃27.YUETT,CHAIFH,ZHANGXM,etal.OzonephotochemistryinsummerinWuqing,Tianjin[J].ResearchofEnvironmentalSciences,2009,22(1):23⁃27(inChinese).[13]㊀程麟钧,王帅,宫正宇,等.京津冀区域臭氧污染趋势及时空分布特征[J].中国环境监测,2017,33(1):14⁃21.CHENGLJ,WANGS,GONGZY,etal.PollutiontrendsofozoneanditscharacteristicsoftemporalandspatialdistributioninBeijing⁃Tianjin⁃Hebeiregion[J].EnvironmentalMonitoringinChina,2017,33(1):14⁃21(inChinese).[14]㊀SICARDP,DEMARCOA,TROUSSIERF,etal.DecreaseinsurfaceozoneconcentrationsatMediterraneanremotesitesandincreaseinthecities[J].AtmosphericEnvironment,2013,79:705⁃715.[15]㊀SEOJ,YOUND,KIMJY,etal.Extensivespatio⁃temporalanalysisofsurfaceozoneoverSouthKoreafor1999⁃2010consideringmeteorologicalfactors//EGUGeneralAssemblyConferenceAbstracts[C].Vienna,Austria,2013.[16]㊀PFISTERGG,WALTERSS,EMMONSLK,etal.QuantifyingthecontributionofinflowonsurfaceozoneoverCaliforniaduringsummer2008[J].JournalofGeophysicalResearch:Atmospheres,2013,118(21):12282⁃12299.[17]㊀SAMUELRS,PADMAK,MILTONBB,etal.Seasonalvariationofsurfaceozoneanditsassociationwithmeteorologicalparameters,UV⁃radiation,rainfallandcloudcoveroverChennai,India[J].CurrentScience,2013,105(5):20⁃23.[18]㊀温彦平.太原市近地面臭氧浓度变化规律及其与气象要素的关系[J].环境工程学报,2015,11(9):5545⁃5554.WENYP,TemporalvariationsofsurfaceozoneanditsrelationswithmeteorologicalparametersinTaiyuanCity[J].ChineseJournalofEnvironmentalEngineering,2015,11(9):5545⁃5554(inChinese).[19]㊀陆克定,张远航,苏杭,等.珠江三角洲夏季臭氧区域污染及其控制因素分析[J].中国科学:化学,2010,40(4):407⁃420.LUDK,ZHANGYH,SUH,etal.RegionalozonepollutionandkeycontrollingfactorsofphotochemicalozoneproductioninPearlRiverDeltaduringsummertime[J].ScientiaSinicaChimica,2010,40(4):407⁃420(inChinese).[20]㊀安俊琳,王跃思,孙杨.气象因素对北京臭氧的影响[J].生态环境学报,2009,18(3):944⁃951.ANJL,WANGYS,SUNY.AssessmentofozonevariationsandmeteorologicaleffectsinBeijing[J].EcologyandEnvironmentalSciences,2009,18(3):944⁃951(inChinese).[21]㊀齐冰,刘寿东,杜荣光,等.杭州地区气候环境要素对霾天气影响特征分析[J].气象,2012,38(10):1225⁃1231.QIB,LIUSD,DURG,etal.ThecharacteristicanalysisofclimaticandenvironmentalfactorsonthehazeweatherinHangzhou[J].MeteorologicalMonthly,2012,38(10):1225⁃1231(inChinese).[22]㊀齐冰,杜荣光,于之锋,等.杭州地区大气细颗粒物浓度变化特征分析[J].环境化学,2015,34(1):77⁃82.QIB,DURG,YUZF,etal.CharacteristicofatmosphericfineparticlesconcentrationsinHangzhouregion[J].EnvironmentalChemistry,2015,34(1):77⁃82(inChinese).[23]㊀严茹莎,陈敏东,高庆先,等.北京夏季典型臭氧污染分布特征及影响因子[J].环境科学研究,2013,26(1):43⁃49.YANRS,CHENMD,GAOQX,etal.CharacteristicsoftypicalozonepollutiondistributionandimpactfactorsinBeijinginsummer[J].ResearchofEnvironmentalSciences,2013,26(1):43⁃49(inChinese).[24]㊀LIUSC,TRAINERM,FEHSENFELDFC,etal.Ozoneproductionintheruraltroposphereandtheimplicationsforregionalandglobalozonedistributions[J].JournalofGeophysicalResearch:Atmospheres,1987,92:4191⁃4207.。

臭氧分析仪设备安全操作规程

臭氧分析仪设备安全操作规程

臭氧分析仪设备安全操作规程臭氧分析仪是一种用于检测空气中臭氧含量的仪器设备,广泛应用于各种工业领域以及实验室中。

在使用臭氧分析仪设备时,应当遵照以下操作规程,确保设备安全和操作准确。

1. 设备安全操作规程1.1. 设备准备在使用臭氧分析仪之前,应仔细检查设备是否正常,并遵照以下步骤准备设备:1.确认设备是否连接电源,并保证电压符合设备标准。

2.检查设备是否连接至配套的采样探头和样品管路。

3.清洗采样探头和样品管路,以免杂质影响检测结果和设备寿命。

4.检查臭氧分析仪的传感器和光路是否清洁,可以使用专用的清洗剂和工具进行清洗。

1.2. 检测前准备在进行臭氧分析检测之前,需要进行以下准备工作:1.预热设备,通常需要数分钟时间。

2.根据检测要求设置设备的参数和检测范围。

3.对样品进行预处理,以确保样品的特性和状态符合检测要求。

1.3. 检测操作在进行臭氧分析检测时,应当遵守以下操作规程:1.保持设备稳定,避免受到外力干扰,如震动或撞击。

2.不要将操作手套,指甲油或其他化学品接触传感器和光路,以避免损坏设备。

3.避免长时间直接暴露在阳光下或高温环境中,以避免设备过热和损坏。

4.不要将检测样品倾斜倒置,以避免样品泼溅和污染设备。

5.确保检测样品与设备参数、检测范围相符,以保证检测准确性和可靠性。

1.4. 操作结束在完成臭氧分析检测之后,应当遵照以下操作步骤:1.关闭设备电源,断开电源线,并拆卸采样探头和样品管路。

2.将样品和采样探头和样品管路中的残留物清除干净,可以使用清洗剂和工具。

3.制定设备保养计划,定期进行设备清洁和维护。

2. 安全警告在使用臭氧分析仪设备的过程中,应当注意以下安全警告:1.禁止设备的自行拆卸和改装,以避免设备损坏和人身伤害。

2.避免长时间直接暴露在高浓度臭氧气体中,以避免对身体健康造成损害。

3.在使用臭氧分析仪设备的过程中,应当严格遵守有关安全法律法规和规范。

4.未经授权的人员不得使用和操作臭氧分析仪设备,以避免设备损坏和人身伤害。

臭氧分析仪的技术参数是怎样的

臭氧分析仪的技术参数是怎样的

臭氧分析仪的技术参数是怎样的臭氧分析仪是一种用于测量空气中臭氧浓度的仪器。

它通常被用于环境监测、空气质量检测以及空气污染控制等领域。

那么,臭氧分析仪的技术参数有哪些呢?本文将会对这个问题进行详细的探讨。

1. 测量原理首先,我们需要了解臭氧分析仪的测量原理。

臭氧分析仪通常采用紫外吸收法测量空气中的臭氧浓度。

具体来说,臭氧分子在紫外线的作用下发生吸收,而其他气体和杂质则不会发生吸收。

因此,通过测量紫外线的强度变化可以推算出空气中臭氧的浓度。

2. 技术参数2.1 测量范围臭氧分析仪的测量范围指的是仪器可以测量的臭氧浓度的范围。

不同型号的臭氧分析仪测量范围不同,一般而言可以从几十ppb到几百ppm。

需要根据实际使用场景来选择合适的测量范围。

2.2 精度和误差臭氧分析仪的精度和误差是衡量仪器好坏的重要指标。

一般来说,臭氧分析仪的精度应该高于1%。

而误差则需要根据实际使用场景来具体考虑。

2.3 响应时间臭氧分析仪的响应时间指的是仪器从检测到臭氧浓度变化后,显示结果所需要的时间。

响应时间一般为几秒到几十秒不等,需要根据实际使用场景来选择合适的响应时间。

2.4 分辨率臭氧分析仪的分辨率指的是仪器可以检测到的最小臭氧浓度变化。

一般而言,臭氧分析仪的分辨率应该达到0.01ppb。

2.5 温度和湿度臭氧分析仪的测量精度和响应时间都会受到环境温度和湿度的影响。

因此,臭氧分析仪的工作温度和湿度范围也需要考虑。

2.6 重复性和稳定性臭氧分析仪的重复性和稳定性也是重要的技术参数。

重复性指的是对同一样本进行多次测量所得结果的一致性,而稳定性则指的是仪器长时间运行时的稳定性能。

3. 总结臭氧分析仪的技术参数包括测量范围、精度和误差、响应时间、分辨率、温度和湿度以及重复性和稳定性等多个方面。

需要根据实际使用场景来选择合适的臭氧分析仪,以确保测量结果的准确性和可靠性。

臭氧O3浓度监测仪

臭氧O3浓度监测仪

臭氧O3浓度监测仪臭氧O3浓度监测仪臭氧O3浓度监测仪产品适用于各种环境和特殊环境中的臭氧O3气体浓度和泄露,在线检测及现场声光报警,对危险现场的作业安全起到了预警作用,此仪器采用进口的电化学传感器和微控制器技术,具有信号稳定,精度高,重复性好等优点,防爆接线方式适用于各种危险场所,并兼容各种控制器,PLC,DCS等控制系统,可以同时实现现场报警和远程显示,报警功能,4-20mA标准信号输出,继电器开关量输出。

信号输出,可选配置为可编程开关量输出等模块,根据用户需求提供定制化产品,还支持输出信号微调等功能,方便系统组网及维护。

可检测O3、CL2、H2S、O3、HCN、SO2、NO2、NOX、O2、O3、PH3、ETO等多种有毒有害气体,详情可咨询东日瀛能。

同时我司臭氧O3浓度监测仪销往:河北省、山东省、辽宁省、黑龙江省、吉林省、甘肃省、青海省、河南省、江苏省、湖北省、湖南省、江西省、浙江省、广东省等全国各地。

(注意:臭氧O3浓度监测仪(SK-600-O3)在不同的应用环境或行业有不同的别名,如臭氧O3浓度监测仪特点■■■■■■■■■智能化EC传感器,采用本质安全技术,可支持多气体、多量程检测,并可根据用户需求提供定制化产品,可实现传感器互换、离线标定和零点自校准智能的温度和零点补偿算法,使仪器具有更加优良的性能具有很好的选择性,避免了其他气体对被检测多种信号输出,既可方便接入PLC/DCS等工控系统,也可以作为单机控制使用臭氧O3变送器臭氧O3探测器便携式臭氧O3探头臭氧O3检测装置)超大点阵LCD液晶显示,支持中英文界面免开盖,电化学遥控器操作,单人可维护本地报警指示,一体化声光报警器(选配)仪器具有超量程、反极性保护,能避免人为操作不当引起的危险丰富的电气接口,可供用户选择通过ATO3、UL、CSA等认证,具有国际化高端品质高精度臭氧O3分析仪臭氧O3检测模块(同时对于不同行业的针对性应用有:臭氧O3报臭氧O3传感器RS485信号输出臭氧O3报警器-20mA信号输出臭氧O3报警器固定式带液晶显示型臭氧O3浓度监测仪带显示带声光报警器固定式臭氧O3浓度监测仪等产品模式)臭氧O3浓度监测仪产品特性:进口电化学传感器具有良好的抗干扰性能,适用寿命8年。

臭氧分析仪检测的原理 分析仪工作原理

臭氧分析仪检测的原理 分析仪工作原理

臭氧分析仪检测的原理分析仪工作原理我们知道地球大气层上有一层臭氧层,科学家们已经发觉臭氧层能吸取紫外线,讨论表明臭氧仅对波长253.7nm的紫外线具有zui大吸取系数,在此波长下紫外线通过臭氧会产生衰减,符合兰波特比尔定律。

该方法已被美国等国家作为臭氧标准分析方法。

该臭氧检测仪就是接受紫外线吸取法的原理,用稳定的紫外灯光源产生紫外线,用光波过滤器过滤掉其它波长紫外光,只允许波长253.7nm通过。

经过样品光电传感器,再经过臭氧吸取池后,到达采样光电传感器。

通过样品光电传感器和采样光电传感器电信号比较,再经过数学模型的计算,就能得出臭氧浓度大小。

臭氧分析仪的检测方法及其原理介绍臭氧浓度检测方法大致可分为“化学分析法”“物理分析法”“物理化学分析法”三类.1.化学检测法1.1碘量法碘量法是zui常用的臭氧测定方法,我国和很多国家均把此法作为测定气体臭氧的标准方法,我国建设部发布的《臭氧发生器臭氧浓度、产量、电耗的测量》标准CJ/T3028.294中即规定使用碘量法.其原理为强氧化剂臭氧(O3)与碘化钾(KI)水溶液反应生成游离碘(I2).臭氧还原为氧气.反应式为:O3 2KI H2OO2 I2 2KOH游离碘显色,依在水中浓度由低至高呈浅黄至深红色.利用硫代硫酸钠(NaS2O3)标准液滴定,反应尽头为完全褪色止.反应式为:I2 2Na2S2O32NaI NaS4O6两反应式建立起O3反应量与NaS2O3消耗量的定量关系为1molO3:2molNaS2O3,则臭氧浓度CO3计算式为:CO3=40x3x1000/1000(mg/L)式中:CO3臭氧浓度,mg/L;ANa硫代硫酸钠标准液用量,ml;B 硫代硫酸钠标准液浓度,mol/L;V0臭氧化气体取样体积,ml.操作程序及方法参照标准CJ/T3028.294.测定标准型发生器浓度很便利.臭氧化气体积用流量计计数,NaS2O3浓度一般配制为0.100mol/L,测定精度可达1%.测定空气中臭氧浓度时,应用在气采样器抽气定量.为保证测定精度,NaS2O3配为0.10mol/L.测定水溶臭氧浓度亦可用此公式计算,只是V0代表采水量,取1000ml.NaS2O3浓度为0.10mol/L.碘量法优点为显色直观.不需要宝贵仪器.缺点是易受其氧化剂如NO、CI2等物质的干扰,在紧要检测时应减除其它氧化物质的影响.1.2比色法比色法是依据臭氧与不同化学试剂的显色或脱色反应程度来确定臭氧浓度的方法.按比色手段分为人工色样比色与光度计色.此法多用于检测水溶解臭氧浓度.国内检测瓶装水臭氧溶解浓度有使用碘化钾、其方式是利用检测样品显色液管相比较,确定测样臭氧溶解度值(0.05~0.08mg/L),要求的,则利用分光光度计检测.国外利用此法做成仪器,配制标准工具与药品作为现场抽检使用,很便利.如美国HACH公司、日本荏原公司的DPD(二己基对苯二胺)比色盘,范围为0.05~2mg/L.美国HACH公司微型比色仪,利用靛蓝染料脱色反应.在600nm波长比色,0.05~0.75nm/L浓度数字显示,精度0.01nm/L.受其它氧化剂干扰少.1.3检测管将臭氧氧化可变化试剂浸渍在载体上,作为反应剂封装在标准内径的玻璃管内做成测管,使用时将检测管两端切断,把抽气器接到检测管出气端吸取定量臭氧气体,臭氧浓度与检测管内反应剂柱变色长度成正比,通过刻度值读取浓度值.德国、日本和我国都生产臭氧检测管,浓度范围分为高(1000ppm)、中(10ppm)、低(3ppm)三种,用于检测空气臭氧浓度,适于现场应用,使用简便,但精度低(为15%).2.物理方法物理方法分析臭氧现在在国际上zui流行的是紫外线吸取法.它是利用臭氧对254nm波长的紫外线特征吸取的特性,依据比尔郎伯(Beer—Lambert)定律制造出的分析仪器,只要选择合适长度的吸取池,就可以检测0.002mg/m3~5%(vol)浓度的臭氧.其线形在4~5个数量级内都很好.该法已被我国作为环境空气中测定臭氧的标准方法(GB1/T1154348).紫外线吸取法不但可以适用于检测气体中臭氧浓度,也可以检测水中溶存的臭氧浓度.紫外线吸取法的仪器在美国、的国、瑞士、日本都有产品.我国北京分析仪器厂于1985年引进了美国莫尼特(MONITORLABS)公司的ML—8810型紫外吸取式臭氧分析器,用于环境检测,1992年以后又连续扩展量程到100ppm、1000ppm.北京超能自控试验技术讨论所在1999年开发了ZX—01系列紫外线吸取式臭氧分析器,其测量范围从0~10ppm(用于环境检测)、0~100ppm、0~1000ppm、0~10000ppm到0~25000ppm.2.1紫外线吸取法原理辐射被某种气体或液体吸取是受朗伯—比尔(LambertBeer)定律掌控的:I=Ioeklc式中Io入射光束的强度;I光束穿透样品(气体或液体)后的强度;l通过样品光程的长度;c样品内吸取物质的浓度;k吸取物质对该光线波长的比吸取系数.此种检测需要对物质在已知波长下k值的了解.2.2臭氧检测臭氧吸取短波紫外区(200~300nm)哈特雷波段紫外光,在253.7nm处具有zui大吸取。

臭氧的浓度分析方法及分析仪器介绍及产品展示

臭氧的浓度分析方法及分析仪器介绍及产品展示

中国工业经济联合会臭氧专业委员会臭氧配套产品展示中心臭氧的浓度分析方法及分析仪器介绍及产品展示概述臭氧在大气层天然产生,在大气层上部形成的臭氧层为短波紫外辐射提供一道屏障,从而保护着地球。

由于臭氧的强氧化能力和强杀菌能力,在生产上特别是在水处理方面的应用日益增长。

臭氧的工业生产是在臭氧发生器的反应器内,利用放电法,空气或氧气通过强电场而获得。

臭氧利用包括将臭氧化气同待处理产物相接触。

例如,在水处理情况下,一项特定处理参数是经一定接触时间后在液体中测剩余臭氧量。

在臭氧自生产或使用过程中,任何泄漏都可能对操作人员或周围设备有害。

臭氧发生或应用的不同场所要求连续、自动和精确地测定广泛浓度范围内不同气体和液体中的臭氧。

经常需要检测臭氧的情况:(1)大气或特定环境空气中的臭氧;(2)工业上生产的臭氧;(3)水中剩余臭氧。

检测方法:根据臭氧发生或应用的场所,对大气或环境中臭氧检测方法是:①紫外辐射吸收法,②乙烯或化学发光法,③电检测法。

工业生产臭氧的检测用:①紫外辐射吸收法,⑦热检测法。

水中剩余臭氧检测用:⑦紫外辐射吸收法,②电检测法,③电位汁法气相臭氧浓度分析仪器介绍及产品展示紫外辐射吸收法原理:辐射披某种气体或液体吸收是受朗伯—比尔律控制的此种检测需要对物质在已知波长下吸收物质对该光线波长的比吸收系数的精确了解。

臭氧检测:具氧吸收短波紫外区(200-300nm)哈特雷波段紫外光,在253.7nm处具有最大吸收。

在此波长,吸收系数值的范围从303.9到313.2cm-1·mol-1·L(273K和760mmHg),研究考证实了该值为302.4cm-1·mol-1·L。

代表仪器:ZX—01系列(增强型)紫外吸收式臭氧分析器ZX—01系列(增强型)紫外吸收式臭氧分析器的特点□ 仪器采用的紫外吸收法,是美国EPA认定的检测臭氧的等效法。

□ 仪器采用微处理器控制,有自检系统,工作可靠,操作简单。

臭氧分析仪校准中的注意事项及测量不确定度评定

臭氧分析仪校准中的注意事项及测量不确定度评定

目前,臭氧已成为环境空气中仅次于PM 2.5的重要污染物。

PM 2.5与臭氧污染的协同控制成为我国“十四五”及更长时期的一个重要任务。

臭氧分析仪用来测量大气中的臭氧浓度,该仪器具有高精度、小体积和低功耗的特点,是远程现场监测和城市网络监测应用的理想工具。

1校准中的注意事项1.1气路的检查以美国赛默飞世尔科技公司生产的49I 型臭氧气体分析仪为例,其测量范围为0~500nmol/mol 。

在对仪器进行测量前先进行气路连接,具体操作如下:1)拧开臭氧气体分析仪旁侧的4个螺丝,打开臭氧气体分析仪的盖子。

2)拆除3个装运螺钉,校准完成后需将装运螺钉拧紧。

3)在仪器背面“sample ”口处连接三通,其中一路连接参比实验室计量标准产生的臭氧标准气体,另外一路排空。

接下来进行气路密闭性的检查,具体操作如下:1)确认各连接口的连接阀是否拧紧。

2)检查管路是否有漏气现象。

3)用气体流量计确认计量标准是否达到输入流量的Precautions and Evaluation ofMeasurement Uncertainty in the Calibration of Ozone AnalyzersJIANG Tianqi ,GUO Xiaoyan ,DONG Jia ,WANG Lin(Liaoning Institute of Measurement,Shenyang 110004,China)Abstract :According to the Notice on Organizing the Implementation of the 2022National Metrology Comparision Projects requirements,the China Environmental Monitoring Center jointly with the China Institute of Metrology as the leading laboratory,organized the implementation of ozone standard metrology comparison work.Liaoning Provincial Metrology Institute participated in this comparison.According to the provisions of JJG 1077—2012Ozone Gas Analyzer inspection regulations,the transmission standard ozone gas analyzer (100±10)nmol/mol (20%FS),(250±10)nmol/mol (50%FS),(400±10)nmol/mol (80%FS)three concentration points were tested,and the test results were expressed in terms of the absolute value of the indicator error.This paper introduces the matters needing attention in the calibration of ozone analyzers in detail,evaluates the measurement uncertainty,and analyzes it.Keywords :ozone analyzers;calibration;metrological comparison;uncertainty臭氧分析仪校准中的注意事项及测量不确定度评定姜天淇,郭小岩,董佳,王琳(辽宁省计量科学研究院,辽宁沈阳110004)【摘要】根据《市场监管总局办公厅关于组织实施2022年国家计量比对项目的通知》要求,中国环境监测总站联合中国计量科学研究院作为主导实验室,组织实施了臭氧计量标准计量比对工作。

一种臭氧浓度分析仪的检测模块[发明专利]

一种臭氧浓度分析仪的检测模块[发明专利]

专利名称:一种臭氧浓度分析仪的检测模块专利类型:发明专利
发明人:张全星
申请号:CN202210039588.6
申请日:20220114
公开号:CN114354527A
公开日:
20220415
专利内容由知识产权出版社提供
摘要:本发明提供一种臭氧浓度分析仪的检测模块,包括:LED紫外光源、石英镜片、紫外光传感器、压力传感器、温度传感器、固定支架,这些元件被集成在固定支架上构成检测模块,检测模块是臭氧浓度分析仪的重要部件。

所述检测模块的优点是:LED紫外光源热稳定性好、寿命长,两条独立检测光路互不干涉,压力传感器和温度传感器可以用于校准测量结果。

因此,所述检测模块具备精准、可靠、稳定的测量条件。

申请人:张全星
地址:100081 北京市海淀区大柳树富海中心2号楼12层1208
国籍:CN
更多信息请下载全文后查看。

model_106臭氧浓度分析仪

model_106臭氧浓度分析仪

Ozone Monitor Models 106-L, 106-M and 106-HFor industrial ozone applications, 2B Tech recently introduced the Model 106-L, 106-M and 106-H Ozone Monitors, where L, M and H refer to Low (0-10 ppm), Medium (0-1000 ppm) and High (0-20 wt%) ozone concentrations, respectively. These instruments have different optical path lengths in order to accomodate this extremely wide range of ozone concentations, spanning more than eight orders of magnitude. Additionally, the Model 106-H was designed with a flow through path that can be pressurized for in-line measurements with ozone generators. The Model 106 series was designed as an "ozone monitor on a board" in which nearly all fo the components are mounted directly to the printed circuit board. Thus, the Model 106 may be purchased without the enclosure for OEM applications.Specifications for Different Optical BenchesModel Range Resolution Precision & Accuracy OEM-106-L 0-10 ppm 0.001 ppm (1 ppb) Higher of 2 ppb or 2% of readingOEM-106-M 0-1000 ppm 0.01 ppm Higher of 0.01 ppm or 2% of reading OEM-106-H 0-20 wt% 0.01 wt% Higher of 0.01 wt% or 2% of readingGeneral SpecificationsMeasurement Principle UV Absorption at 254 nmMeasurement Interval10 s (Data averaging options: 10 s, 1 min, 5 min, 1 hr) Flow Rate~1 Liter/minData Storage14,336 lines (10 s avg. = 1.4 days; 5 min avg = 1.4 mo.)Choice of Units ppb, ppm, pphm, µg m-3, mg m-3 (& mol %, wt % for 106H)Data Outputs USB, RS232, 0-2.5 V Analog, 4-20 mA, LCD Display Power Requirements12 V, 3.5 wattSize 3.75 x 7.5 x 8.5 inches (10 x 19 x 22 cm)Weight 4.3 lb (2.0 kg)Features∙Measurement based on UV absorption∙Low power consumption; can be battery operated∙Exchangeable optical benches for extremely wide dynamic range of 1 ppb to 5 wt%∙Internal data logger with real time clock∙On-board microprocessor with interactive menus includes data averaging options of 10 s, 1 m,5 m and 1 hr∙USB and RS-232 output of time/date, O3 concentration, internal temperature and pressure ∙Analog output (0-2.5 V and 4-20 mA) of ozone concentration in user selected units∙Two level relay for control purposes (e.g., control of ozone source or turn warning light on and off)。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

Ozone Monitor Models 106-L, 106-M and 106-H
For industrial ozone applications, 2B Tech recently introduced the Model 106-L, 106-M and 106-H Ozone Monitors, where L, M and H refer to Low (0-10 ppm), Medium (0-1000 ppm) and High (0-20 wt%) ozone concentrations, respectively. These instruments have different optical path lengths in order to accomodate this extremely wide range of ozone concentations, spanning more than eight orders of magnitude. Additionally, the Model 106-H was designed with a flow through path that can be pressurized for in-line measurements with ozone generators. The Model 106 series was designed as an "ozone monitor on a board" in which nearly all fo the components are mounted directly to the printed circuit board. Thus, the Model 106 may be purchased without the enclosure for OEM applications.
Specifications for Different Optical Benches
Model Range Resolution Precision & Accuracy OEM-106-L 0-10 ppm 0.001 ppm (1 ppb) Higher of 2 ppb or 2% of reading
OEM-106-M 0-1000 ppm 0.01 ppm Higher of 0.01 ppm or 2% of reading OEM-106-H 0-20 wt% 0.01 wt% Higher of 0.01 wt% or 2% of reading
General Specifications
Measurement Principle UV Absorption at 254 nm
Measurement Interval10 s (Data averaging options: 10 s, 1 min, 5 min, 1 hr) Flow Rate~1 Liter/min
Data Storage14,336 lines (10 s avg. = 1.4 days; 5 min avg = 1.4 mo.)
Choice of Units ppb, ppm, pphm, µg m-3, mg m-3 (& mol %, wt % for 106H)
Data Outputs USB, RS232, 0-2.5 V Analog, 4-20 mA, LCD Display Power Requirements12 V, 3.5 watt
Size 3.75 x 7.5 x 8.5 inches (10 x 19 x 22 cm)
Weight 4.3 lb (2.0 kg)
Features
∙Measurement based on UV absorption
∙Low power consumption; can be battery operated
∙Exchangeable optical benches for extremely wide dynamic range of 1 ppb to 5 wt%
∙Internal data logger with real time clock
∙On-board microprocessor with interactive menus includes data averaging options of 10 s, 1 m,
5 m and 1 hr
∙USB and RS-232 output of time/date, O3 concentration, internal temperature and pressure ∙Analog output (0-2.5 V and 4-20 mA) of ozone concentration in user selected units
∙Two level relay for control purposes (e.g., control of ozone source or turn warning light on and off)。

相关文档