瑞士MEMBRAPOR臭氧传感器O3-C-5 7系列传感器 大气环境污染指数专用 高精度
FY3星紫外臭氧总量探测仪(TOU)监测大气臭氧及吸收性气溶胶
0 引言 近年来,我国气溶胶大气污染事件(如沙尘、
灰霾等)的发生越来越频繁,尤其在我国北方地区, 除受沙尘天气的影响外,受灰霾的影响也较大[1]。灰 霾等污染事件伴随的主要污染物为气溶胶和痕量气体 (O3 、SO2及NO2等),因此对它们进行大范围的星 载监测有助于我国大气环境污染的预报。
国际上对痕量气体和气溶胶的星载监测起步于20 世纪70年代。1979年,TOMS(Total Ozone Mapping
由中国科学院国家空间科学中心研制的臭氧总
量探测仪(TOU)是我国自主开发研制的用于全球 臭氧总量监测的仪器[12],于2008年开始搭载在气象卫 星风云三号A星(FY-3A)发射,之后的FY-3B星和
30 Advances in Meteorological Science and Technology 气象科技进展 9(1)- 2019
Progress 研究进展
FY-3C星先后搭载TOU发射成功,至今已有三台TOU 仪器在轨运行。TOU的成功发射和运行实现了我国臭 氧总量探测从无到有的过程,从根本上改变了我国大
(1 National Space Science Center, Chinese Academy of Sciences, Beijing 100190 2 National Satellite Meteorological Centre, Beijing 100081
3 University of Chinese Academy of Sciences, School of Astronomy and Space Science, Beijing 100049)
的星载紫外探测仪器被发射并进行痕量气体的探测, 如欧州空间管理局的GOME-1[4-5]、SCIAMACHY[6]、 GOME-2[4],以及美国的OMI [3]和OMPS[7-8]等。此外, 这些仪器还进行吸收性气溶胶指数的反演 [9-11],用于
tgs2602.pdf tgs2000 系列传感器产品介绍,空气污染、臭味检测用说明书
TGS2602 空气污染、臭味检测用特点: 应用:・低功耗 ・空气清新机、换气扇控制 ・对VOC 、氨气、硫化氢有高灵敏度 ・脱臭器控制・长寿命、低成本 ・室内空气监视器・可利用简单电路下图是典型的香烟烟雾灵感度特性。
香烟的根数是约10平米的房间吸烟情况下的数值。
这里的纵轴也用传感器电阻比Rs/Rs(Air)来表示, 这里的Rs 、Rs(Air)定义如下: Rs =香烟的烟雾存在时的传感器电阻值 Rs(Air) =清洁大气中的传感器电阻值 香烟灵敏度特性:敏感素子由集成的加热器以及在氧化铝基板上形成的金属氧化物半导体构成。
当可检知的气体存在时,空气中该气体的浓度越高,传感器的电导率就越高。
使用简单的电路就可以将这种电导率的变化变换为与气体浓度对应的输出信号。
TGS2602不仅对香烟的烟雾或烹调臭味有很高的灵敏度,而且对硫化氢、VOC 、氨气有高灵敏度。
这种传感器是利用相对值检知来实现更接近人类感觉的控制,即以空气清洁的时候为基准,通过传感器电阻值比空气清洁时变化了多少来检测空气的污染程度。
下图是典型的灵敏度特性,全部是在标准试验条件下得出的结果。
(请看背面) 纵轴以传感器电阻比Rs/Rs(Air)表示,Rs 、Rs(Air)的定义如下: Rs =各种浓度气体中的传感器电阻值Rs(Air)=清洁大气中的传感器电阻值灵敏度特性:规格: 结构及尺寸:型 号 TGS2602素子类型 26系列 标准封装 金属 对象气体氢气、酒精等检测范围 1 ~10 ppm标准回路加热器电压 VH 5.0±0.2V DC/AC 回路电压 VC 5.0±0.2V DC Ps 15mW ≦ 负载电阻 RL 可变Ps 15mW ≦标准试验加热器电阻 RH59 Ω(室温)加热器电流 IH 56mA 加热器功耗 PH 280mW VH =5.0V DC/AC 传感器电阻Rs10~100 K Ω(空气中) 灵敏度(Rs 的变化率)0.15~0.5Rs(乙醇:10 )Rs(Air)标准试验试验气体条件 20±2℃,65±5%RH 回路条件 VC =5.0±0.2V DCVH =5.0±0.2V DC/AC试验前预热时间 96小时以上功耗(Ps )值可用下式计算: 传感器电阻(Rs ),可根据VOUT测定值,用下式计算:为提高性能,本规格书将不事先预告而变更。
维萨拉工业测量产品手册说明书
维萨拉工业测量产品手册湿度 | 温度 | 露点 | 二氧化碳 | 沼气 | 油中水分 | 连续监测系统 |溶解气体分析系统 | 过氧化氢 | 压力 | 气象 | 服务支持观测让世界更美好维萨拉的工业测量业务领域产品能够帮助客户了解工艺过程。
我们的产品为客户提供准确可靠的测量数据,帮助客户做出优化工业过程的决策,从而提高过程效率、产品质量、生产力和产量,同时减少能源消耗、浪费和排放。
我们的监测系统还能帮助客户在受监管的环境中运营,以履行监管合规性。
维萨拉工业测量服务于多种类型的运营环境,从半导体工厂和高层建筑,到发电厂和生命科学实验室,对环境条件的可靠监测是实现成功运营的先决条件。
维萨拉的测量产品和系统广泛应用于监测温度、湿度、露点、气压、二氧化碳、汽化过氧化氢、甲烷、油中水、变压器油中溶解气体和液体浓度等参数。
我们的生命周期服务可在测量仪表的整个使用寿命内提供维护。
作为值得信赖的合作伙伴,我们通过在产品和系统生命周期中保证准确的测量数据来支持客户做出可持续的决策。
本产品目录对我们的产品进行整体的介绍,以帮助您选择适合您需求的产品。
如需更多信息,请通过以下方式联系我们:销售热线:400 810 0126电子邮箱:**********************公司网址:扫描二维码,关注维萨拉企业微信3目 录Indigo系列变送器Indigo200系列数据处理单元 (7)Indigo300数据处理单元 (9)Indigo510数据处理单元 (12)Indigo520数据处理单元 (15)用于抽检和校准的手持设备Indigo80手持式显示表头 (18)HMP80系列手持式湿度和温度探头 (21)DMP80系列手持式露点和温度探头 (23)HM70手持式湿度和温度仪 (26)HUMICAP® 手持式湿度温度仪表HM40系列 (29)DM70手持式露点仪 (33)MM70适用于现场检测的手持式油中微量水分和温度测试仪 (36)湿度和温度用于测量相对湿度的维萨拉HUMICAP® 传感器 (38)如何为高湿度应用选择合适的湿度仪表 (40)Insight PC机软件 (44)HMP1墙面式温湿度探头 (46)HMP3一般用途湿度和温度探头 (48)HMP4相对湿度和温度探头 (51)HMP5相对湿度和温度探头 (54)HMP7相对湿度和温度探头 (57)HMP8相对湿度和温度探头 (60)HMP9紧凑型湿度和温度探头 (63)TMP1温度探头 (66)适用于苛刻环境中湿度测量的HMT330系列温湿度变送器 (68)HMT370EX系列本安型温湿度变送器 (78)HMT310温湿度变送器 (84)HUMICAP® 温湿度变送器HMT120和HMT130 (87)适用于高性能暖通空调应用的HMW90系列湿度与温度变送器 (90)HMD60系列湿度和温度变送器 (92)HMD110/112和HMW110/112湿度和温度变送器 (96)适用于楼宇自动化高精度室外测量的HMS110系列温湿度变送器 (99)HMDW80系列温湿度变送器 (101)适用于楼宇自动化应用室外测量的HMS80系列温湿度变送器 (105)HMM100湿度模块 (107)适用于OEM应用的HMM105数字湿度模块 (109)HMM170温湿度模块 (111)INTERCAP® 温湿度探头HMP60 (113)4INTERCAP® 温湿度探头HMP63 (115)HUMICAP® 温湿度探头HMP110 (117)HUMICAP® 温湿度探头HMP113 (120)SHM40结构湿度测量套件 (122)HMK15湿度校准仪 (125)DTR500太阳辐射和雨水防护罩 (127)HMT330MIK气象安装套件 (129)适用于动力汽轮机进气测量的HMT300TMK汽轮机安装组件 (131)露点Vaisala DRYCAP® 传感器用于测量干燥过程中的湿度 (133)DMP5露点和温度探头 (135)DMP6露点探头 (138)DMP7露点和温度探头 (140)DMP8露点和温度探头 (142)DMT340系列露点和温度变送器 (145)适用于高温应用的DMT345和DMT346露点变送器 (151)DMT152露点变送器 (155)DMT143露点变送器 (157)DMT143L露点变送器 (160)用于冷冻干燥机的DMT132露点变送器 (162)DM70用DSS70A便携式采样系统和采样室 (164)DPT146露点和气压变送器 (166)DPT145多参数变送器 (168)二氧化碳适用于苛刻环境的维萨拉CARBOCAP® 测量传感器 (171)GMP343二氧化碳探头 (173)适用于CO2恒温箱的GMP231二氧化碳探头 (176)GMP251二氧化碳探头 (178)GMP252二氧化碳探头 (181)GM70手持式二氧化碳测试仪 (184)适用于苛刻通风要求应用的GMW90系列二氧化碳及温湿度变送器 (187)适用于智能控制通风系统 (DCV) 的GMW80系列二氧化碳、湿度和温度一体变送器 (190)按需控制通风系统中的GMD20系列二氧化碳变送器 (193)GMD110管道安装式二氧化碳变送器 (195)沼气MGP261多气体探头 (197)MGP262多气体探头 (199)油中水用于测量油中微水的维萨拉HUMICAP® 传感器 (201)MMP8油中水分探头 (203)MMT330系列油中微量水分与温度变送器 (205)5MMT310系列油中微量水分与温度变送器 (209)MMT162油中微量水分和温度变送器 (211)连续监测系统维萨拉viewLinc企业版服务器版本5.1 (213)AP10 VaiNet无线接入点 (215)用于连续监测系统的RFL100无线数据记录仪 (218)HMP115温湿度探头 (223)TMP115宽范围温度探头 (225)维萨拉温度与相对湿度数据记录仪系列DL2000 (227)维萨拉通用输入数据记录仪系列DL4000 (229)维萨拉多应用温度数据记录仪DL1016/1416 (231)维萨拉热电偶数据记录仪系列DL1700 (233)维萨拉中端温度、湿度及触点通道数据记录仪 (235)维萨拉vNet以太网供电数据记录仪接口 (238)溶解气体分析OPT100 Optimus™ 溶解气体分析(DGA)监测系统 (240)MHT410变压器油中微量水分、氢气和温度分析仪 (244)过氧化氢用于测量汽化过氧化氢、相对饱和度和相对湿度的维萨拉PEROXCAP® 传感器 (246)用于过氧化氢、湿度和温度测量的HPP270系列探头 (249)压力用于测量压力的维萨拉BAROCAP® 传感器 (253)PTU300气压、湿度和温度一体变送器 (255)适用于专业气象、航空与工业用户的PTB330数字式气压计 (260)气压传递标准PTB330TS (262)PTB210数字气压计 (265)PTB110气压计 (267)将风引起误差降低的SPH10/20静压头 (269)气象Vaisala用于工业应用测量的风和气象传感器技术 (271)风测量装置WA15 (273)WINDCAP® 超声波风传感器WMT700系列 (276)气象变送器WXT530系列 (278)服务支持面向仪表全生命周期服务 (280)67功能•数据处理单元 USB-C 端口支持使用通用 USB 电缆连接到维萨拉Insight PC 软件•数字和图形彩色显示屏(针对模拟型号提供可选的不带显示屏的款式)•IP65 外壳•24 V AC/DC 电源输入•Indigo201:3 个模拟输出(mA 或 V)•Indigo202:RS-485,带有Modbus ® RTU•2 个可配置的继电器维萨拉 Indigo200 系列数据处理单元是一种主机设备,它显示来自维萨拉 Indigo 兼容探头的测量值,同时也可通过模拟信号、Modbus RTU 通信或继电器将这些测量值传输到自动化系统。
瑞士MEMBRAPOR超低量程二氧化硫传感器SO2-C-1
SIDE VIEW
<1 ppm ~30 ppm 0 ppm ~-125 ppm <1 ppm 0 ppm
Performance data conditions: 20 °C, 50% RH and 1013 mbar APPLICATIONS Safety and Environmental Control
PHYSICAL CHARACTERISTICS
Weight Position Sensitivity Storage Life Recommended Storage Temperature Warranty Period ~ 13 g None Six months in container 5° C – 20 ° C 12 months from date of dispatch
on 17.0 mm PCD
The data contained in this document is for guidance only. Membrapor AG accepts no liability for any consequential losses, injury or damage resulting from the use of this document or the information contained within it. The data is given for guidance only. Customers should test under their own conditions, to ensure that the sensors are suitable for their own requirements.
深圳市深国安电子科技有限公司
空气质量传感器
举例来说,下面是温度影响一氧化碳敏感度的基准数据:
—10℃
24nA/ppm CO
25℃
31nA/ppm CO
50℃
34nA/ppm CO
产品构造 产品的尺寸为 35mm 的方形,9.5mm 的高度。在四个角的位置各有一个安全的孔。表面上 有一个可以接入 1.5mm*31mm 的 ID 口的 O 形凹槽,确保了产品的密封性。这样可以防止 污染气体从传感器后面进入而引起的读数错误的现象出现。
低成本 设计构造简单以及很少的部件使得其成本得到降低,从而形成更有竞争力的价格。
感应气体种类广 对一氧化碳,二氧化硫,硫化氢,酒精,乙醛,氢气,二甲醚和乙烯敏感,对烷烃,酮,芳 香烃,二氧化碳和水蒸气不具有敏感性。
长寿命 它使用的是在世界范围内已经有 30 多年使用经验的呼吸酒精传感器的元件。而呼吸酒精传 感器的精度,稳定性和长久性都是已经得到了验证的。
响应快速 一条短小且低阻抗的扩散路径使其响应时间很少
电源要求低 燃料电池原理意味着它并不需要电源激励,仅仅在信号的处理和显示时需要电能,所以仅仅 一个简单的小电池单元即可。
稳定性 非常好的稳定性,允许在使用过程中非常长的校准周期
可承受高压 采用非薄膜构造,不包含在高压环境下容易破碎的元件,经验证,可以承受 10 个大气压力。
信号放大 输出信号放大的首选方法是使用一个直接的电流到电压放大的运算放大器。这样的话传感器 将工作在其最好的模式下。得到的信号值取决于反馈电阻的大小;比方说使用 1000 欧姆的 电阻值,那么一个输出为 5nA 的信号将会转化为 5mV 的输出信号。 因为在开路状态传感器可能会逐渐引起偏移,虽然不会对产品有损伤,但是也要花费时间去 放电。所以在储藏期间一般将输出端子进行短路处理,这样就不会出现明显的长期的偏移量 。 在使用过程中,为了避免在放大器被断开的时候偏移量的增加,可以在两端子之间连接一个 低阻值的电阻(典型值为 620 欧姆)。另外,也可将放大器持续供电。 下面给出典型的应用电路:
埃森545系列烟气湿度仪产品介绍最终版
HMS535C 外观大机壳 传感器30C
外观小机壳
传感器35传感器
电源在铝盒内部
无按工况分类型号
电源在铝盒下面
按工况分具体型号
目录
535C和545结构尺寸比较
机壳尺寸 325 ×260(mm)
机壳尺寸 235 ×200(mm)
目录
内部图比较
HMS545
HMS535C+
目录
HMS545P便携式水分仪
HMS545W机壳为灰白色
目录
技术规范 烟气水分测量范围: 0…40vol% 准确度: ≤±2% 响应时间: ≤30S 湿度传感器: 阻容式 温度传感器: PT100铂电阻 输出信号: 4…20mA 供电电源: 220vAC(50HZ) 功耗: 25W 传感器温度: 0…80 C 变送器及控制部分: -10…+55 C 工作环境湿度: 0…100RH% 使用工况: 采用特殊工艺及DW技术 ,专用于脱硫 后未安装或未使用GGH低温高湿的场合
mm目录hms545ahms545chms545whms545d外观颜色灰白色蓝色灰白色黑色机壳尺寸mm235x200235x200235x200235x200应用行业火力发电垃圾焚烧适用工况氨法脱硫常规水分仪丌适于氨法脱流和低温高湿场合脱硫后未用ggh的低温高湿场合高温工况温度180客户选型目录针对工况丌同hms535c在线式水分仪hms545系列在线式水分仪升级hms545系列水分仪目录hms535c和hms545比较外观大机壳外观小机壳传感器30c传感器35传感器电源在铝盒内部电源在铝盒下面hms535chms545按工况分具体型号无按工况分类型号目录535c和545结构尺寸比较机壳尺寸325260mm机壳尺寸235200mm目录内部图比较hms545hms535c目录升级hms545phms545phms545p便携式水分仪目录现场存取测量校准内置充电式电池hms545p便携式烟气水分仪目录24v电源适配器重量更轻内置新品电池内部集成化hms545p升级内容目录产品亮点
氢能发电厂专用瑞士进口Membrapor氢气H2传感器
氢能发电厂专用瑞士进口Membrapor氢气H2传感器氢能发电厂瑞士Membrapor氢气H2传感器一、产品介绍富安达带来的Membrapor氢气传感器是玻璃行业氢气检测仪器的主要核心部件,产品性能精度高、一致性好、重复性好、高稳定性、高分辨率、抗干扰能力强,可在低温下使用,是全球知名企业信赖的传感器,也是国家安全生产总局主要推荐的传性好,同时量程选择多,最高量程可以达到10000ppm以上,同时可根据客户需求定制不同量程的传感器。
Membra感器,主要应用于氢能发电厂氢气泄露检测场合,传感器的输出性能稳定,线por以其无可匹敌的实力和压倒性的技术优势雄居电化学气体传感器世界之首。
二、传感器工作原理瑞士进口Membrapor氢气传感器其工作原理是根据电化学的原理工作,利用待测气体在电解池中工作电极上的电化学氧化过程,通过电子线路将电解池的工作电极和参比电极恒定在一个适当的电位,在该电位下可以发生待测气体的电化学氧化,由于氧在氧化和还原反应时所产生的法拉第电流很小,可以忽略不计,于是待测气体电化学反应所产生的电流与其浓度成正比,通过测定电流的大小就可以确定待测气体的浓度。
三、产品概述氢是通过一定的方法利用其它能源制取的一种不依赖化石燃料的储量丰富的可再生能源。
它的主要优点有:燃烧热值高,每千克氢燃烧后的热量,约为汽油的3倍,酒精的3.9倍,焦炭的4.5倍;燃烧的产物除水和少量氮化氢外不会有其它有害物质,少量的氮化氢经过适当处理也不会污染环境。
氢能发电,指利用氢气和氧气燃烧,组成氢氧发电机组。
氢气发电用为一种新洁能源的优点a.氢气的来源广泛,可以由水制得。
b.氢气燃烧的热值比化石燃料高(如下图).大约是汽油热值的二倍。
c.最突出的优点是燃烧产物是水,不污染环境因此氢能源具有广阔的开发前景。
②氢气的性质a.氢气的物理性质:通常情况下,氢气是无色、无味的气体,难溶于水,密度是0.089g/L,比空气密度小,是最轻的气体。
臭氧分级标准
臭氧分级标准
臭氧分级标准是根据臭氧在大气中浓度的不同,将其分为不同的级别以指导和评价空气质量。
在国际上,常用的臭氧分级标准为8小时平均值(8-hour daily maximum)和1小时平均值(1-hour daily maximum)两种。
以下是美国环境保护署(EPA)针对臭氧污染的分级标准:
1. 8小时平均值(ppb):
- Good(优良): 0-54
- Moderate(中等): 55-70
- Unhealthy for Sensitive Groups(对敏感人群不健康): 71-85 - Unhealthy(不健康): 86-105
- Very Unhealthy(非常不健康): 106-200
- Hazardous(危险): >200
2. 1小时平均值(ppb):
- Good(优良): 0-70
- Moderate(中等): 71-85
- Unhealthy for Sensitive Groups(对敏感人群不健康): 86-105
- Unhealthy(不健康): 106-200
- Very Unhealthy(非常不健康): 201-400
- Hazardous(危险): >400
需要注意的是,具体的分级标准可能会因地区、国家以及组织的不同而有所不同。
testo350XL中文使用说明书
简明操作手册
Rev. 11/03 仪器软件版本号 1.30
800-227-0729
.cn
上海市襄阳南路218号现代大厦708-709 Tel:86-21-64723900 Fax:86-21 -54561470
4
4.1 4.2 4.3
选择燃料....................................................... 19
更改燃料.................................................................... 19 CO 稀释系统................................................................. 19 选择O2 参考值用于自动计算.................................................... 20
删除整个内存..........................................................24
6
6.1 6.2 6.3
数据管理....................................................... 25
数据存储在烟气分析箱........................................................ 25 设置新的文件夹或地址........................................................ 26 删除文件夹或地址............................................................ 27
OZONIA臭氧技术介绍
36
多段式放电管设计
多段式自对中设计 ==> 放电间隙更小 ==> 冷却效果更好 ==> 放电电压更低 ==> 发生效率高 ==> 电耗更低
多段式自对中设计
2010年5月17日
得利满技术有限公司
37
单独保险丝设计-提高安全性
单独保险丝,最大限度确保连续运行 避免因某一根放电管故障导致整个系统 停机而影响生产
水流速率
得利满技术有限公司
31
尾气破坏器-加热型
尾气 20 °C
热分解器 270 °C
热交换器 80 °C
加热器
Half-Life [s]
350 °C
350 °C
1 day 1 hour 103 p = 1bar 1
0.07 s 10-3
排放气 10-6 100
500
900
Temperature [°C]
工业
2010年5月17日
市政
• 饮用水 • 废水 • 回用水
• 制药 • 个人用品 • 化学
• 石油石化 • 电子 • 食品饮料
得利满技术有限公司
• 瓶装水 • 水产 • 印染
• 纸浆&造纸
28
臭氧投加系统
辐流曝气器
臭氧
尾气
微孔曝气头
臭氧
尾气
常用于前臭氧
常用于后臭氧
2010年5月17日
得利满技术有限公司
2010年5月17日
得利满技术有限公司
14
臭氧 vs 氯气
Ammo氨ni氮a nitrogen Iron an铁d 、ma锰nganese
V病iru毒s
Ozone Chlorine Bacte细ri菌a
2015瑞士Membrapor有毒气体传感器选型表
0 – 1,000 0 – 5,000 0 - 50 0 - 50 0 - 100 0 - 100 0 - 200 0 - 200 0- 500 0 – 1,000 0 – 1,000 0 – 2,000 0 – 5,000 0 – 5,000 0 – 10,000 0 – 10,000 0 – 20,000 0-1 0 - 20 0 - 20 0- 20 0 - 100 0 - 100 0 - 100 0 – 2,000 0 – 2,000 0 – 2,000 0 – 2,000 0 - 20 0 - 20 0 - 50 0 - 50 0 - 200 0 - 200 0 – 5,000 0-1,000 0-1,000 0 – 1,000 0 – 1,000 0 – 1,000 0 – 2,000 高灵敏度 高灵敏度 高灵敏度,带 CO 补偿 高灵敏度,带 CO 补偿 高灵敏度,带 CO 补偿 带过滤器 带过滤器 沼气池专用传感器 大量程 大量程 大量程,沼气池专用传感 器,超强抵抗力 大气环境监测 高灵敏度 高灵敏度 高灵敏度,带过滤器 带过滤器 带过滤器 2 电极 沼气池专用传感器 高灵敏度 高灵敏度
CO/MF-2000
0 – 2,000 0 – 2,000 0 – 2,000 0 – 4,000 0 – 4,000 0 – 10,000 0 – 10,000 0-40,000
带过滤器,带 H2 补偿,大 量程 带过滤器,带 H2 补偿,大 量程 带过滤器,大量程 高灵敏度 高灵敏度 2 电极, 高灵敏度
气体
S 系列(替代 3 系)
传感器种类 C 系 列 ( 替 代 7 M 系列 ( 替代 4 量程(PPM) 系) 系)
备注/应用
CO/SF-200 CO/SF-200-S CO/SFA-200 CO/SFA-200-S CO/SF-2E CO/SF-2E-S CO/S-500 CO/S-500-S
环境空气臭氧量值溯源传递标准
环境空气臭氧量值溯源传递标准1范围本标准规定了环境空气臭氧量值溯源传递标准的术语和定义、紫外光度计臭氧溯源传递流程和系统操作原理、高压电离法臭氧溯源传递流程和系统操作原理和技术要求。
本标准适用于操作经校准合格的臭氧传递标准对下级环境空气臭氧量值溯源传递标准进行校准工作。
本标准适用于校准紫外光度计法有效量程在InnIol∕mol~500nπιol∕InoI之内和高压电离法校准有效量程在20μπιol∕πκ)l~1000μmol∕mol之内的臭氧传递。
2规范性引用文件下列文件对于本文件的应用是必不可少的。
凡是注日期的引用文件,仅注日期的版本适用于本文件。
凡是不注日期的引用文件,其最新版本(包括所有的修改单)适用于本文件。
HJ590-2010环境空气臭氧的测定紫外光度法3术语和定义下列术语和定义适用于本文件。
3.1环境空气臭氧量值溯源传递标准依据相关操作规程,能够准确再现或者准确分析、可以溯源到更高级别或者更高权威标准臭氧浓度的可运输仪器设备。
环境空气臭氧量值溯源传递标准用于传递臭氧一级标准的权威性或者用于校准监测站点的臭氧分析仪器。
注:臭氧传递标准可根据工作原理分为发生型传递标准、分析型传递标准和带有臭氧发生器的分析型传递标准。
可根据在臭氧量值传递链中的位置分为二级传递标准、三级传递标准和四级传递标准。
3.2发生型传递标准该类传递标准仅含有臭氧发生器、不含有臭氧光度计•,通过调节发生器的功率调整发生的臭氧浓度,不能对发生的臭氧浓度进行实时测定。
发生型传递标准仅适用于校准现场臭氧分析仪,不适用于校准分析型传递标准。
3.3分析型传递标准该类传递标准含有臭氧光度计,能够实时测定臭氧发生器发生的臭氧浓度。
分析型传递标准可用于校准分析型传递标准、发生型传递标准和现场臭氧分析仪。
部分分析型传递标准自带有臭氧发生器,在发生臭氧的同时可实时测定发生的臭氧浓度,并对臭氧发生器进行实时的反馈调节。
3.4一级传递标准臭氧一级标准的臭氧量值经过传递标准的逐级传递,最终传递至现场臭氧分析设备(图1)O图1臭氧量值逐级传递链示意图3.5二级传递标准由臭氧一级标准进行校准的传递标准,量值可直接溯源到一级标准。
空气污染传感器HS135
技术参数 HS-135 气体传感器特点:
广泛的探测范围快速的响应恢复及较高的灵敏度
长期的工作稳定性简单的测试电路
应用
用于家庭、环境的有害气体探测装置。
适宜于氨气、氮氧化合物、醇类、芳族化合物、硫化物、烟雾、
等的探测。
规格:
图.2
热器构成的敏感元件固定在塑料或不锈钢制成的腔体内,加热器为气敏元件提供了必要的工作条件。
封装好的气敏元件有6只针状管脚,其中4个用于信号取出,2个用于提供加热电流。
测量电路如图2。
E. 灵敏度特性曲线
灵敏度调整:
HS-135型气敏器件对不同种类,不同浓度的气体有不同的电阻值。
因此,在使用此类型气敏元件时,灵敏度的调整是很重要的。
我们建议您用100ppm 氨或50ppm 酒精蒸气校准传感器。
当精确测量时,报警点的设定应考虑温湿度的影响。
O3臭氧气体传感器
O3臭氧气体传感器O3臭氧气体传感器特点:★整机体积小,重量轻★高精度,高分辨率,响应迅速快.★上、下限报警值可任意设定,自带零点和目标点校准功能,内置温度补偿,维护方便.★数据恢复功能,免去误操作引起的后顾之忧.★外壳采用特殊材质及工艺,不易磨损,易清洁,长时间使用光亮如新.O3臭氧气体传感器技术参数:★进口电化学传感器具有良好的抗干扰性能,使用寿命长达3年;★采用先进微处理器技术,响应速度快,测量精度高,稳定性和重复性好;★全量程范围温度数字自动跟踪补偿,保证测量准确性;★半导体纳米工艺超低功耗32位微处量器;★全软件自动校准,传感器多达6级目标点校准功能,保证测量的准确性和线性,并且具有数据恢复功能;★防高浓度气体冲击的自动保护功能O3臭氧气体传感器结构图:O3臭氧气体传感器接线示意图:一氧化氮NO 气体传感器参数工作电压DC5V±1%/DC24±1%波特率9600测量气体一氧化氮NO 气体检测原理电化学采样精度±2%F.S 响应时间<30S重复性±1%F.S 工作湿度10-95%RH,(无冷凝)工作温度-30~50℃长期漂移≤±1%(F.S/年)存储温度-40~70℃预热时间30S 工作电流≤50mA 工作气压86kpa-106kpa安装方式7脚拔插式质保期1年输出接口7pIN 外壳材质铝合金使用寿命2年外型尺寸(引脚除外)33.5X3121.5X31测量范围详见选型表输出信号TTL(标配)0.4-2.0VDC(常规)/4-20mA数字信号格式数据位:8;停止位:1;校验位:无;传感器PIN脚定义图:传感器应用场所:医药科研、学校科研、制药生产车间、烟草公司、环境检测、楼宇建设、消防报警、污水处理、石油石化、化工厂、冶炼厂、钢铁厂、煤炭厂、热电厂、锅炉房、加气站、垃圾处理厂、隧道施工、输油管道、工业气体过程控制、室内空气质量检测、地下燃气管道检修、危险场所安全防护、设备检测等。
臭氧分析仪校准中的注意事项及测量不确定度评定
目前,臭氧已成为环境空气中仅次于PM 2.5的重要污染物。
PM 2.5与臭氧污染的协同控制成为我国“十四五”及更长时期的一个重要任务。
臭氧分析仪用来测量大气中的臭氧浓度,该仪器具有高精度、小体积和低功耗的特点,是远程现场监测和城市网络监测应用的理想工具。
1校准中的注意事项1.1气路的检查以美国赛默飞世尔科技公司生产的49I 型臭氧气体分析仪为例,其测量范围为0~500nmol/mol 。
在对仪器进行测量前先进行气路连接,具体操作如下:1)拧开臭氧气体分析仪旁侧的4个螺丝,打开臭氧气体分析仪的盖子。
2)拆除3个装运螺钉,校准完成后需将装运螺钉拧紧。
3)在仪器背面“sample ”口处连接三通,其中一路连接参比实验室计量标准产生的臭氧标准气体,另外一路排空。
接下来进行气路密闭性的检查,具体操作如下:1)确认各连接口的连接阀是否拧紧。
2)检查管路是否有漏气现象。
3)用气体流量计确认计量标准是否达到输入流量的Precautions and Evaluation ofMeasurement Uncertainty in the Calibration of Ozone AnalyzersJIANG Tianqi ,GUO Xiaoyan ,DONG Jia ,WANG Lin(Liaoning Institute of Measurement,Shenyang 110004,China)Abstract :According to the Notice on Organizing the Implementation of the 2022National Metrology Comparision Projects requirements,the China Environmental Monitoring Center jointly with the China Institute of Metrology as the leading laboratory,organized the implementation of ozone standard metrology comparison work.Liaoning Provincial Metrology Institute participated in this comparison.According to the provisions of JJG 1077—2012Ozone Gas Analyzer inspection regulations,the transmission standard ozone gas analyzer (100±10)nmol/mol (20%FS),(250±10)nmol/mol (50%FS),(400±10)nmol/mol (80%FS)three concentration points were tested,and the test results were expressed in terms of the absolute value of the indicator error.This paper introduces the matters needing attention in the calibration of ozone analyzers in detail,evaluates the measurement uncertainty,and analyzes it.Keywords :ozone analyzers;calibration;metrological comparison;uncertainty臭氧分析仪校准中的注意事项及测量不确定度评定姜天淇,郭小岩,董佳,王琳(辽宁省计量科学研究院,辽宁沈阳110004)【摘要】根据《市场监管总局办公厅关于组织实施2022年国家计量比对项目的通知》要求,中国环境监测总站联合中国计量科学研究院作为主导实验室,组织实施了臭氧计量标准计量比对工作。
LH-HPES系列高精度环境传感器说明书
高精度环境传感器说明书适用型号:LH-HPES系列修订记录:目录1.产品介绍 (3)2.规格参数 (3)3.产品尺寸 (4)4.485通信协议与数据格式 (4)4.1.通讯基本参数 (4)4.2.数据帧格式定义 (5)4.3.功能码说明 (5)4.4.寄存器地址 (6)4.5.参数读取 (6)5.线序定义 (7)6.售后服务 (8)6.1.售后服务承诺 (8)6.2.免责声明 (8)6.3.联系方式 (8)1.产品介绍LH-HPES系列高精度环境传感器是我司推出的高精度、高可靠性、耐湿度环境传感器。
产品采用瑞士进口温湿度传感器、双通道二氧化碳传感器及高精度亮度传感器。
内置进口意法半导体芯片,并采用了高可靠性防护电路设计,内置多重防水保证高湿度环境的可用性。
产品响应速度快,性能稳定可靠,采用标准ModbusRTU通讯协议,可接入现场数显表、PLC、变频器、工控主机等设备。
产品广泛适用于高标农田、蔬菜大棚、食用菌培养、酿造发酵、食品储藏、地铁停车场、畜牧业养殖。
2.规格参数3.产品尺寸4.485通信协议与数据格式4.1.通讯基本参数4.2.数据帧格式定义采用Modbus-RTU通询规约,格式如下:地址码=1字节功能码=1字节数据区=N字节错误校验=16位CRC码结束结构>=4字节的时间地址码:为设备的地址,在通询网络中是唯一的。
功能码:主机所发指令功能提示。
数据区:数据区是具体通询数区,注意16bits数据高字节在前。
CRC码:二字节的校验码。
地址码功能码寄存器起始地址寄存器长度校验码低位校验码高位问询1字节1字节2字节2字节1字节1字节地址码功能码有效字节数数据区校验码低位校验码高位应答1字节1字节1字节2字节1字节1字节4.3.功能码说明4.4.寄存器地址寄存器地址表适用于本系列各个型号产品,请根据所购型号选择对应的寄存器。
(特别注意:使用PLC设备读取时,需要将寄存器加1,如:使用03功能码读取0001寄存器,需要写入40002)4.5.参数读取(1)例:读取设备地址为01的传感器温湿度主机发送:010*********C40B设备响应:0103040106023F5A BE注释:将返回的十六进制数据转换成十进制除以10,即可得到相应的温湿度值。
瑞典SenseAir原装进口二氧化碳CO2传感器S8
Gas and Air SensorsProduct SpecificationSenseAir S8Miniature CO2 sensor module 深圳市深国安电子科技有限公司SenseAir ® S8 Miniature infrared CO 2 sensor moduleFigure 1. SenseAir ®S8 Article no. 004-0-0013Warning! ESD sensitive device!Table 1. Key technical specification for the SenseAir ® S8__________________________________________________________________________________________ Note 1: Sensor is designed to measure in the range 400 to 2000 ppm with specified in the table accuracy. Nevertheless exposure to concentrations below 400 ppm may result in incorrect operation of ABC algorithm and shall be avoided for model with ABC on.Note 2: Sensor provides readings via UART in the extended range but the accuracy is degraded compared to specification in the table one.Note 3: In normal IAQ applications. Accuracy is defined after minimum 3 weeks of continuous operation with ABC on.However, some industrial applications do require maintenance. Please, contact SenseAir for further information!Note 4: Accuracy is specified over operating temperature range. Specification is referenced to certified calibration mixtures.Uncertainty of calibration gas mixtures (+-2% currently) is to be added to the specified accuracy for absolute measurements.Note 5: See specification { Modbus on SenseAir_R_S8 rev_P11_1_00.doc preliminary specification}G+ G0Alarm_OC PWM 1kHzDVCC_out UART_RxD UART_TxD UART_R/T bCAL_inAbsolute maximum ratingsStress greater than those listed in Table 2 may cause permanent damage to the device. These ratings are stress ratings only. Operation of the device at any condition outside those indicated in the operational section of these specifications is not implied. Exposure to absolute maximum rating for extended periods may affect device reliability.Table 2. Absolute maximum ratings specification for the SenseAir ®S8__________________________________________________________________________________________Note 1: Specified parameter relies on specification of subcontractor and is not tested by SenseAir Note 2: Refer chapter “Terminal Description” for rated voltage inf ormationNote 3: Alarm_OC pin is internally pulled up to G+. External pull up to higher voltage will provide resistive divider poweringsensor via high resistance.Sample gas diffusion areaFigure 2. Diffusion areaPin assignmentFigure 3. Pin assignmentDiffusion areaTerminals descriptionThe table below specifies terminals and I/O options dedicated in SenseAir ® S8model.Table 3. I/O notations, description and electrical specification. (continued on next page)Table 3. I/O notations, description and electrical specification (continue, see previous page).__________________________________________________________________________________________ Note 1: Specified parameter relies on specification of subcontractor and is not tested by SenseAir深圳市深国安电子科技有限公司Mechanical propertiesSensor PCB may be colour green or black. Optical Bench Assembly (OBA) may be colour silver or black.Please refer to mechanical drawing for detailed specification of dimensions and tolerances.WARNING!Under no circumstances apply any force to the OBA, this may permanently harm the sensor and most definitely affect performance.Sensor should be handled holding PCB only. Never touch sensor with bare hands, make sure that operators use ESD gloves.Note! ESD sensitive device!Never apply force to OBA!Handle sensor by holding PCB only! Never touch sensor with bare hands!Figure 4. Mechanical properties SenseAir ®S8 Article No 004-0-0013Installation and solderingDuring installation and assembly of sensor to PCB it is essential that compatible materials are used and that soldering process is managed. Avoid introduction of stress to the sensor’s PCB or OBA. SenseAir recommends hand soldering only.NB! Transport, handling and assembly may affect calibration. Accuracy is defined after minimum 3 weeks of continuous operation with ABC in normal IAQ applications. However, some industrial applications do require maintenance.Please contact SenseAir for further information!OBAWarning! ESD sensitive device!深圳市深国安电子科技有限公司Maintenance and ABC (Automatic Baseline Correction)The models based on SenseAir ® S8platform are basically maintenance free in normal environments thanks to the built-in self-correcting ABC algorithm (Automatic Baseline Correction). This algorithm constantly keeps track of the sensor’s lowest reading over preconfigured time interval and slowly corrects for any long-term drift detected as compared to the expected fresh air value of 400ppm (or0.04%vol) CO2.Discuss your application with SenseAir in order to get advice for a proper calibration strategy.When checking the sensor accuracy, PLEASE NOTE that the sensor accuracy is defined at continuous operation (at least 3 weeks after installation with ABC turned on)!Table 4. ABC default configurations for SenseAir ® S8 Article no. 004-0-0013CalibrationRough handling and transportation might result in a reduction of sensor reading accuracy. With time, the ABC function will tune the readings back to the correct numbers. The default “tuning speed” is however limited to about 30-50 ppm/week.For post calibration convenience, in the event that one cannot wait for the ABC algorithm to cure any calibration offset two manual calibration procedures are offered. A switch input is defined for the operator or master system to select one of the two prepared calibration codes.Optional calibrations are bCAL(background calibration),which requires that the sensor is exposed to fresh air (400 ppm CO2) and CAL(zero calibration), which requires the sensor measuring cell to be completely evacuated from CO2 e.g. by exposing it to Nitrogen or Soda Lime CO2 scrubbed air. Make sure that the sensor environment is steady and calm!深圳市深国安电子科技有限公司Self-diagnosticsThe system contains complete self-diagnostic procedures. A full system test is executed automatically every time the power is turned on. In addition, constantly during operation, the sensor probes are checked against failure by checking the valid dynamic measurement ranges. All EEPROM updates, initiated by the sensor itself, as well as by external connections, are checked by subsequent memory read back and data comparisons.These different system checks return error bytes to the system RAM. The full error codes are available from the UART communication port. Out of Range error is the only bit that is reset automatically after return to normal state. All other error bits have to be reset after return to normal by UART overwrite, or by power off/on.Error code and action plan(Error code can be read via UART communication port)Note 1. Any probe is out of range. Occurs, for instance, during over-exposure of CO2 sensor, in which case the error code will automatically reset when the measurement values return to normal. Could also indicate the need of zero point calibration. If the CO2 readings are normal, and still the error code remains, any other sensor probe mounted (if any) can be defect, or the connection to this probe is broken.Please note: If several errors are detected at the same time the different error code numbers will be added together into one combined error code!SenseAir ®AB SenseAir ®North AmericaS enseAir ®Chengdu Gas Sensors Ltd.Box 961603 S. Eastside Loop, Suite 207 First floor 8th of Xingke Road Stationsgatan 12 Tucson, AZ 85710 Hi-Tech Industry Park SE- 82060 Delsbo USA Jinniu district, Chengdu Sweden Sichuan province ChinaPhone: +46(0)653 – 71 77 70 Phone: +1 52.0.207.5032 Phone: +86-028 - 875 928 85 Fax: +46(0)653 – 71 77 89Fax: +86-028 – 875 928 85 E-mail: info@ E-mail: infoamerica@ E-mail: info@ Web page: Web page: Gas and Air Sensors深圳市深国安电子科技有限公司。
瑞士MEMBRAPOR原装进口高精度臭氧气体传感器O3-C-2大气环境监测专用 可以检测到0.01PPM
The data contained in this document is for guidance only. Membrapor AG accepts no liability for any consequential losses, injury or damage resulting from the use of this document or the information contained within it. The data is given for guidance only. Customers should test under their own conditions, to ensure that the sensors are suitable for their own requirements.
Compact-Size Outline Dimensions BOTTOM VIEW 4 5° Reference 4 5° Sensing Counter
17.0 mm PCD Nonconnected Pin 24 mm
Typical Baseline Range (pure air, 20°C) Maximum Zero Shift (+20°C to 0.1 ppm +40°C) Long Term Output Drift < 2% signal loss/month Recommended Load Resistor 10 Ohm Bias Voltage Not recommended Repeatability 5 % of signal Output Linearity Linear (*) The sensor has no protection against condensation CROSS-SENSITIVITY DATA Interfering Gas Concentration CO H2 SO2 H2S NO NO2 Ethylene Cl2 200 ppm 200 ppm 5 ppm 35 ppm 5 ppm 100 ppm 5 ppm
利用探空资料验证GOME卫星臭氧数据-Harvard-SmithsonianCenter
2.1 GOME卫星数据
Global Ozone Monitoring Experiment (GOME)具有320×40 km2 的空间分辨率。文中应用的
臭氧廓线资料是由Liu Xiong等利用最优估计方法反演的产品,该产品能够给出从地面到平流层
为了进一步验证该版本GOME臭氧资料在中国地区应用的可行性和精度,本文利用三个站 点的臭氧探空资料对GOME 2.1版臭氧廓线及对流层柱总量(TCO)进行了详细验证,同时对拉 萨郊区(91.16°E,29.65°N,海拔3650m)、瓦里关山(100.9° E,36.28° N,海拔3810m)、临 安(119.73°E,30.30°N,海拔132m)观测的地面臭氧浓度与近地面层GOME臭氧浓度进行了对 比。探空站点为拉萨(91.3°E,29.7°N,海拔3510m),西宁(101.75°E,36.63°N,海拔2296m) 和北京(116.39°E,39.79°N,海拔40m),采用的两种气球探空仪分别是进口电化学探空仪ECC (拉萨(EN-SCI公司),西宁(芬兰VAISALA公司))tract: Global Ozone Monotoring Experiment (GOME) on board second Earth Remote Sencing (ERS-2)launched in 1995. To evaluate the performance of GOME’s ozone data in China, ozone sonde observations at three stations in Lhasa(1998-1999), Xining(1996), and Beijing(2002-2003) are used to validate ozone profiles and tropospheric column ozone retrieved from Global Ozone Monitoring Experiment (GOME). Ozone detecting systems are Electrochemical concentration cell (ECC) sonde at Lhasa and Xining and GPSO3 sonde at Beijing; GOME data are retrieved by Liu et al.. A comparison data set consists of 51 matching pairs were obtained by applying a baseline criteria ( ± 6h, ± 3 0 longitude, ± 1.5 0 latitude). A statistical analysis of the differences between coincident O3 profiles obtained by GOME and ozone sondes was conducted using the methodology suggested by von Clarmann. When comparing with measurements that have much better vertical resolution than satellite retrievals, we apply retrieval averaging kernels to the high-resolution data so that we are comparing the same data . As the high-resolution sondes profiles do not cover the GOME retrieval altitude range, we augment the high-resolution profile (ozone sonde only up to ~30 km) with monthly mean climatological profiles from TOMS V8. Statistical bias determination and precision validation show that in the lower and middle troposphere, the mean biases are significant within 5% at Lhasa and Xining and within 10% at Beijing. In the upper troposphere and lower stratosphere, the mean biases are within 10% at Lhasa and Xining and within 20% at Beijing. In the middle and upper stratosphere, the mean biases are within 5% at all three locations. The larger bias in the troposphere and lower stratosphere at Beijing may result from a different type of ozone sonde and different time period (ozone profiles shows multiple peaks in Beijing area in the spring). The mean biases of the tropospheric column ozone are within 10% at all three sites, which are partly caused by different estimated tropopause heights between GOME and ozone sondes. The GOME monthly mean ozone concentration at 0-2.5 km correlates well with surface ozone measurements, basically capturing the temporal variations of surface ozone at Lhasa, Waliguan, and Linan. In conclusion, from lower troposphere to upper stratosphere, GOME data used here has strong ability to analysis ozone distribution and dynamic changes in China. Key words: validation, ozone profile, tropospheric column ozone, GOME
A3CO Enviroce 说明书
Every effort has been made to ensure the accuracy of this document at the time of printing. In accordance with the company s policy of continued product improvement City Technology Limited reserves the right to make product changes without notice. No liability is accepted for any consequential losses, injury or damage resulting from the use of this document or from any omissions or errors herein. The data is given for guidance only. It does not constitute a specification or an offer for sale. The products are always subject to a programme of improvement and testing which may result in some changes in the characteristics quoted. As the products may be used by the client in circumstances beyond the knowledge and control of City Technology Limited, we cannot give any warranty as to the relevance of these particulars to an application. It is the clients responsibility to carry out the necessary tests to determine the usefulness of the products and to ensure their safety of operation in a particular application.Circuitry requiredThe A3CO EnviroceL differs from standard three electrode sensors by the introduction of a second working electrode, known as the Auxiliary . A suitable operating circuit is shown below.When no gas is present, there is a small zero gas (baseline) signal from each electrode. Upon exposure to carbon monoxide, the sensing electrode produces a signal proportional to the concentration of gas. Virtually all the gas is reacted on contact with this electrode, so the auxiliary electrode remains largely unaffected and hence the signal remains at its baseline level. It can therefore be assumed the auxiliary signal is wholly attributed to the baseline.The baseline signal of both electrodes is slightly affected by changes in atmospheric conditions (e.g. temperature). However as both are subject to the same conditions, any shift in baseline on the sensing electrode will be followed by a similar shift in the auxiliary . Hence by comparing the two signals any baseline changes may be compensated.Evaluating the carbon monoxide concentration of a sample from the two signals is a straightforward subtraction:-.Let:Then Figure 1.A3CO Operating Circuit英国CT气体传感器 CITY城市技术气体传感器常用型号选型样本 CITY公司/IT公司/SENSORIC公司气体传感器选购指南 英国CT气体传感器快速选型产品系列用途3系列种类齐全的毒气气体传感器4系列主要应用于便携式气体检测仪5系列排放气体传感器系列7系列用于一般气体检测的传感器医用系列氧气传感器是专为呼吸及麻醉应用而设计的产品汽车系列用于汽车尾气排放分析仪MICROceL微型气体传感器Sensoric毒气传感器Sixth Sense一氧化碳传感器工业安全监测气体类型产品名称 使用寿命 量程 产品描述一氧化碳C O MICROceL CF2CF2E/F3E3E/F3ME/F4CF4CO4COSH7E7E/F9CFA7EA7E/FCO 2E 300CO 3E 300CO 3E 500 SE ZT3E/F2年空气中2年空气中2年空气中3年空气中3年空气中3年空气中2年空气中2年空气中3年空气中3年空气中3年3个月空气中3年空气中3年>3 years>4 years>2 years空气中3年0-1500ppm0-1000ppm0-500ppm0-2000ppm0-2000ppm0-2000ppm0-1500ppm0-1500ppm0-1500ppm CO0-500ppmH2S0-2000ppm0-2000ppm0-200ppm0-2000ppm0-2000ppm0-300ppm0-500ppm0-500p三电极一氧化碳传感器带内置过滤器二电极微型传感器二电极,带H2S过滤器三电极三电极,带H2S过滤器三电极,带H2S过滤器和mV输出板三电极微型,带H2S和SO2过滤器三电极微型四电极微型二气(CO和H2S)三电极微型三电极微型,带H2S和SO2过滤器二电极,使用寿命三个月四电极,带氢气补偿四电极,带H2S、SO2过滤器,和H2补偿两电极,有4系和7系等三种尺寸.三电极,有4系和7系等三种尺寸.三电极传感器,有4系和7系等三种尺寸.三电极,带H2S过滤器和4-20mA传输板0-500p mp硫化氢H 2 S MICROceL HS3H3HH3HH/LM3MH4COSH4H4HS7H7HH7HH/LM9HHEZT3HH2S 2E 30H2S 2E 50H2S 2E 50 SH2S 3E 100H2S 3E 100 SH2S 3E 302年空气中2年空气中2年空气中2年空气中2年空气中3年空气中2年空气中2年空气中2年空气中2年空气中2年空气中3个月空气中2年>18 月>18 月>4 years>4 years>4 years>18 months0-1000ppm0-1000ppm0-500ppm0-500ppm0-500ppm0-1500ppm CO0-500ppmH2S0-500ppm0-500ppm0-1000ppm0-500ppm0-500ppm0-200ppm0-200ppm0-30ppm0-50ppm0-50ppm0-100ppm0-100pMICRO三电极硫化氢传感器三电极传感器三电极传感器,高量程三电极传感器,对甲烷交叉干扰低三电极传感器,带mV输出板四电极微型二气传感器(CO和H2S)三电极微型传感器,高干扰三电极微型传感器三电极微型传感器三电极微型传感器,高干扰三电极微型传感器,对甲烷交叉干扰低二电极传感器,使用寿命三个月三电极传感器带4-20mA传输板两电极,有机电极、有4系和7系等三种尺寸.两电极,有4系和7系等三种尺寸.三电极,有4系和7系等三种尺寸.三电极,有4系和7系等三种尺寸.三电极,有4系和7系等三种尺寸.0-30ppm氧气O 2 4OX-14OX-27OX-VC/2C/2PNC/NC/NLHC/NLLC/SC/YMICROceL OXT7OX-VI-05I-01I-02I-04I-06I-08P-10P-40P-40F OS-65空气中1年空气中2年空气中2年空气中18个月空气中1年空气中9个月平衡平衡空气中9个月空气中1年空气中2年空气中2年3年6年6年3年4年4年2年2年2年0-30%0-30%0-30%0-30%0-30%0-30%0-1000ppm0-1000ppm0-30%0-30%0-30%0-25%0-100%0-35%0-35%0-100%0-100%0-25%0-21%0-21%0-1%0-65%微型传感器,塑料容器微型传感器,塑料容器微型传感器–塑料罐。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
ELECTROCHEMICAL GAS SENSORS
REV.: 6/2004 Page 1 of 1 SPECIFICATION SHEET FOR O3 SENSOR TYPE O3/C-5
PERFORMANCE CHARACTERISTICS
CROSS-SENSITIVITY DATA
Interfering Gas Concentration Reading
CO 200 ppm 0 ppm
H2200 ppm 0 ppm
SO2 5 ppm 0 ppm
H2S No data yet
NO35 ppm 0 ppm
NO2 5 ppm ~ 5 ppm
Ethylene 100 ppm 0 ppm
Cl2 5 ppm ~ 4 ppm
Performance data conditions:
20 °C, 50% RH and 1013 mbar
APPLICATIONS
Continuous Air Quality Monitoring
Safety and Environmental Control
PHYSICAL CHARACTERISTICS
BOTTOM VIEW
SIDE VIEW
Compact-Size Outline Dimensions
The data contained in this document is for guidance only. Membrapor AG accepts no liability for any consequential losses, injury or damage resulting from the use of this document or the information contained within it. The data is given for guidance only. Customers should test under their own conditions, to ensure that the sensors are suitable for their own requirements.
Nominal Range 0 – 5 ppm
Maximum Overload 50 ppm
Expected Operation Life 2 years in air
Output Signal - 1500 ± 500 nA/ppm
Resolution 0,02 ppm
Temperature Range - 20 °C to 45 °C
Pressure Range Atmospheric ± 10%
Pressure Coefficient No data
T80 Response Time < 60 sec
Relative Humidity Range 15 % to 90 % R.H.non-
condensing
Typical Baseline Range (pure
air, 20°C)
< 0,1 ppm
Maximum Zero Shift (+20°C to
+40°C)
0,1 ppm
Typical Long Term Output Drift < 2% signal loss/month
Recommended Load Resistor 10 Ohm
Bias Voltage Not recommended
Repeatability 5 % of signal
Output Linearity Linear
Weight ~ 13 g
Position Sensitivity None
Storage Life Six months in
container
Recommended Storage
Temperature
5 °C – 20 °C
Warranty Period 12 months from date
of dispatch
深圳市深国安电子科技有限公司
地址:广东省深圳市龙华新区牛栏前大厦C507电话:86 755-85258900
网址:www.singoan.com www.singoan.com.cn www.shenguoan.com 。