WRFLZ-2900电磁流量计(4P)

合集下载

意大利伊莱科流量指示器与流量指示仪说明书

意大利伊莱科流量指示器与流量指示仪说明书

FLOW METERS AND INDICATORS MUST BE MOUNTED AT LEAST 50mm FAR FROM IRON PARTS OR WALLS AND OTHER POSSIBLE INTERACTING MAGNETIC FIELD. WARNING: any combination of the switching voltage and current must not exceed the given rated po簧 M6 粘度至14/4 cSt. • 弹簧 M7 粘度至39/8 cSt. • 弹簧 M8 粘度至70/4 cSt. • 弹簧 M9 粘度至119/2 cSt. • 弹簧 M10 粘度至205/6 cSt.
流量指示器以及流量指示器在安装时必须离内墙或者钢铁物体至少50 毫米的地方,要远离可能引起干扰的磁场。
CONVERSION TABLE OF WATER/AIR FLOW RATE RELATIVE TO
IF...V-VE-E FLOW METERS AND INDICATORS
Model Water LPM Air Nm3/h
IF1... 0.1 - 01
0.2 - 2
IF2... 0.2 - 03
0.35 - 5
IF3...
1 - 06
2 - 10
IF4...
2 - 16
3.5 - 29
IF5...
5 - 60
10 - 110
SPRINGS TO BE USED WITH FLUIDS MORE VISCOUS THAN WATER • Spring M6 Viscosity up to 14.4 cSt. • Spring M7 Viscosity up to 39.8 cSt. • Spring M8 Viscosity up to 70.4 cSt. • Spring M9 Viscosity up to 119.2 cSt. • Spring M10 Viscosity up to 205.6 cSt.

电磁流量计选型样本

电磁流量计选型样本
DN6-DN80:≤1.6MPa, DN100-DN250:≤1MPa,
:DN300-DN1200:≤0.6MPa 高压可定制
6)流量测量范围:
联系电话:010-87832746 010-61794317
网址
3
北京中航科仪测控技术有限公司
四 氟 乙 烯 和 F4 或 ETFE 乙烯
聚乙烯
PO
聚苯硫醚
PPS
化学性能略 逊于 F4
化 学 性 能 稳 60<℃ 定
150<℃
腐蚀性的酸 碱盐液体
腐蚀性的酸 碱盐液体 污水 热水
联系电话:010-87832746 010-61794317
网址
6
北京中航科仪测控技术有限公司
Qmax(m3/h) 271.0 424.0 662.0 954.0
内径(mm) 400
450
500
外接电源≤35V 导通时集电极最大电流为 250mA 10)供电电源:85-265V,45-63HZ 11)直管段长度:管道式:上游≥5DN,下游≥2DN 12)连接方式:流量计与配管之间均采用法兰连接,法兰连接尺寸应符合 GB11988 的规定. 13)防爆标志:MDIIBT4 14)环境温度湿度:-25℃-+60℃;5%-95%. 15)消耗总功率:小于 20W
流量测量范围对应流速范围是 0.1-15m/s
7)电导率范围: 被测流体电导率≥5us/cm(一体式),大多数以水为成分的介质,其电导率在 200-800 us/cm 范围内,均可选用电
磁流量计来测量其流量计. 8)电流输出: 负载电阻:0-10mA 时,0-1.5k¦¸ ,
4-20mA 时,0-750k¦¸ , 9)数字频率输出:输出频率上限可在 1-5000HZ 内设定带光电隔离的晶体管集电极开路双向输出.

WP-EMF系列电磁流量计_普通

WP-EMF系列电磁流量计_普通
POWER
~ 22 0V
直流电源 流量积算
- + 123456
图1.4(f)圆表电磁计数器接线
24VAC F U S E: 4 A
FUSE
220VAC FU SE: 1A
POWER
流量积算 123456
~ 22 0V
图1.4(g)圆表电子计数器接线
下限报警
24VAC F U S E: 4 A
FUSE
COM:报警输出地
TRX+:通讯输入
TRX-:通讯输入
TCOM:232通讯
LINE:220V(24V)电源输入
LINE:220V(24V)电源输入
1.3.4 分体式线盒接线图
传感器(端子盒)
SIG1 SIG2 SGND
SIG1:信号1 SIG2:信号2 SGND:信号地 EXT+:励磁电流+ EXT-:励磁电流-
型号
说明
WP-EMF-
结构形式 C D
一体夹持式电磁流量计 分体夹持式电磁流量计
口径
() 1
口径从DN40~DN200 不锈钢(316L)
2
哈氏合金B(HB)
电极
3 4
哈氏合金C(HC) 铂
5
钛(Ti)
6
钽(Ta)
9
其它
D
可溶性聚四氟乙烯(PFA)
衬里材料
E G
聚全氟乙丙烯(F46) 可溶性聚四氟乙烯(耐负压)(PFA)
复合键
图1.2.1 圆表键盘定义与液晶显示
1.3转换器接线图 1.3.1方表端子接线与标示
RS485
PE
P OW ER
PE
图1.3(a)方表接线端子图
2

朝辉压力仪器 电磁流量计 用户手册说明书

朝辉压力仪器  电磁流量计 用户手册说明书

上海朝辉压力仪器有限公司电磁流量计产品说明书目录一、电磁流量计产品概述、特点及用途1.1 产品概述1.2 产品特点1.3 产品应用二、工作原理2.1数学模型2.2转换器电路结构三、产品型式和组成3.1产品型式3.2产品组成3.3 电极和衬里的选择四、产品主要技术性能指标4.1整机和传感器4.2流量范围4.3防护等级说明4.4防爆标准4.5转换器主要性能五、产品外观尺寸及安装尺寸5.1转换器外形尺寸5.2传感器外形和安装尺寸六、转换器菜单结构及参数设置6.1按键形式6.2按键功能6.3参数设置功能及操作密码6.4参数菜单一览表6.5参数设置菜单说明七、流量计安装图示八、电气接线8.1流量计与管道的接地8.2转换器接线端子与标示8.3输出信号接线九、自诊断信息与故障处理十、供应成套性十一、运输与贮存十二、运行附录:产品保修卡一、电磁流量计产品概述、特点及用途1.1产品概述电磁流量计(Electromagnetic Flowmeter,简称EMF)是20世纪50~60年代随着电子技术的发展而迅速发展起来的新型流量测量仪表。

电磁流量计是应用电磁感应原理,根据导电流体通过外夹磁场时感生的电动势来测量导电流体流量的一种仪表。

1.2电磁流量计具有以下特点★不受流体密度、粘度、温度、压力和电导率变化的影响,线性测量原理能实现高精度测量;★测量管内无阻流及活动部件,压力损失小,因此不会造成额外的能量损失,也不会造成堵塞,节能效果显著,特别适宜液固两相流介质,如污水、泥浆、矿浆、纸浆等的测量。

★安装要求低,前直管段只要求5D,后直管段为2D(D为所选仪表的内直径)★公称通径DN3-DN3000覆盖范围宽,衬里和电极有多种选择,能满足测量多种导电流量的要求;★具有MODBUS-RS485、HART、GPRS和PROFIBUS等通讯信号输出(选配)★转换器采用32位嵌入式微处理器,全数字处理,运算速度快,抗干扰能力强,测量可靠,精确度高,测量范围度可达1500:1★高清晰度背光LCD显示,全汉字菜单操作,使用方便,操作简单,易学易懂;★具有电导率测量功能,可以判别传感器是否空管,具有自检与自诊断功能;★内部计算器可分别显示正向累积流量、反向累积流量及瞬时流量。

电磁流量计选型手册

电磁流量计选型手册

法兰外 径(mm)
D
95 105 115 140 150 165 185 200 235 270 300 340 395 445 505 565 615 670 780 895 1015 1115 1175 1405 1630 1830 2045 2265
近似质量(Kg) 一体式 分体式
4 AMAG-W 电磁流量计(夹持式)
295
22
250
10"
450 203 429
350
22
300
12"
500 230 482
400
22
350
14"
550 260 534
460
22
400
16"
600 290 594
515
26
450
18"
1.0
600 320 649
565
26
500
20"
600 358 697
620
26
600
24"
600 420 799
35
1760
35
1800 72"
1970
39
2000 80"
2180
42
备 法兰尺寸参照 GB/T 9119,以上为理论尺寸,若有出入,以实际尺寸为准。
注 L 的公差(mm),DN15-DN150:+0~-3;DN200-DN2000:+0~-5。
螺栓 数量
n
4 4 4 4 4 4 8 8 8 8 8 8 12 12 16 16 20 20 20 24 24 28 28 32 36 40 44 48

唐山大方汇中仪表 LZD系列 智能电磁流量计 说明书

唐山大方汇中仪表 LZD系列 智能电磁流量计 说明书

LZD系列智能电磁流量计安装使用说明书唐山大方汇中仪表有限公司通过ISO9001:2008质量管理体系认证冀制02000110Ex1.3.7压力:1.6Mpa;2.5Mpa; 6.4Mpa; 16Mpa; 25Mpa; 42Mpa 1.3.8使用环境:环境温度:-20℃~+50℃ 相对湿度:5%~90%1.3.9空管自动报警1.3.10机械振动频率:≤55Hz 振幅:≤0.15mm 1.3.11平均无故障工作时间:MTBF=30000h 1.3.12防护等级:IP67或IP651.3.13防爆标志:Exd(ia)iaqⅡCT51.3.14衬里材料:聚氨酯橡胶、氯丁橡胶;聚四氟乙烯;F46衬里。

1.3.15电极材料:不锈钢、316L、HB;特殊材料(如:钛、钽、铂等稀有金属材料。

)1.3.16供电电源:85~265VAC或18~36VDC 1.3.17额定功率:小于10W二、工作原理及结构2.1工作原理电磁流量计的工作原理基于法拉第电磁感应定律。

当一个导体在磁场内运动时,在与磁场方向、运动方向相互垂直方向的导体两端,会有感应电动势产生。

电动势的大小与导体运动速度和磁感应强度大小成正比。

在图下中,当导电流体以平均流速V(m/s)通过装有一对测量电极的一根内径为D (m)的绝缘管子流动时,并且该管子处于一个均匀的磁感应强度为B(T)的磁场中,将在一对电极上就会感应出垂直于磁场方向和流动方向的电动势(E)。

有电磁感应定律可写做(1)式:q v =πD 24V(m 3/ )s ...................(2)由公式(1)和(2)可得到:q v =πD 4E B(m 3/ )s (3)通常,体积流量可以写作唐山大方汇中仪表有限公司0315-2833937唐山新华西道21号http://www.tsdafang.com图三、执行标准3.1执行标准Q/DF004-2009 LZD系列电磁流量计U因此电动势可表示为:E=πD4B q v(v) (4)当B是个常数时,公式(3)中πD 41B =k,公式(3)改写为:q v =kE (m 3/ )s因此,流量 与电动势E成为正比。

电磁流量计---ROSEMOUNT

电磁流量计---ROSEMOUNT
2013-8-12 集气总站---刘勤洋 3
• 流量计应配带接地环
• 流量计与管道之间采用法兰连接,法兰密 封面为ANSI 150磅 RF面 • 流量计电气接口应为1/2” NPT(F)(2个), 并应配带进线口的金属密封堵头一个
2013-8-12
集气总站---刘勤洋
4
对防爆等级的理解
• 人为地将爆炸限制在一个有限的局部范围内, 使该范围内的爆炸不致于引起更大范围的爆炸。 典型代表为隔爆型防爆方法Exd。工作原理是: 为仪表设计一个足够坚固的壳体,按标准严格 地设计、制造和安装所有的界面,使在壳体内 发生的爆炸不致于引发壳体外危险性气体(易 爆气体)的爆炸。隔爆防爆方法的设计与制造 规范极其严格而且安装、接线和维修的操作规 程也非常严格。该方法决定了隔爆的电气设备、 仪表往往非常笨重,操作须断电等,但许多情 况下也是最有效的办法。
罗斯蒙特电磁流量计
我们任用、培养最优秀人才,不断学习,不断成长,不断 挑战自我,共同投入到工作中。
汇报人 -------刘勤洋(普光集气总站)
2013-8-12
集气总站---刘勤洋
1
• • • • • • •
一、技术协议的学习 二、正在使用的电磁流量计介绍 三、电磁流量计原理简诉 四、电磁流量计安装条件 五、电磁流量计的选型 六、电磁流量计的一些故障事例 七、电磁流量计的内部拆开结构
2013-8-12
集气总站---刘勤洋
20
• 非满管时
• 倾斜非满管的管道需 要加泄放口。空管检 测功能。测量管道是 否充满。 • 有残渣积聚场合,不 要将传感器安装在倾 斜管道的最低处。建 议安装清洁阀。
2013-8-12 集气总站---刘勤洋 21
• 垂直管道

FMG90系列电磁流量计操作手册说明书

FMG90系列电磁流量计操作手册说明书

FMG90 SeriesElectromagnetic Flow Meter- 2 - M-5204/0615Table of contents page 0About this operating manual (4)1Device description (5)1.1Intended use (6)1.2Exclusion of liability (6)2Safety instructions (7)3Construction and function (8)4Installation of FMG90 (8)4.1Installation instructions (9)4.2Assembly (10)5Electrical connection (11)6Commissioning and measuring operation (12)6.1Commissioning (12)6.2Measuring operation (12)7Maintenance and cleaning (12)8Disassembly and disposal (13)9Technical data (14)9.1Characteristics FMG90 (14)9.2Materials table (15)9.3Pressure drop (15)9.4Dimensions (16)Copyright notice:The reproduction, distribution and utilization of this operating manual as well as the communication of its contents to others without express authorization is prohibited. Offenders will be held liable for the payment of damages. All rights reserved in the event of the grant of a patent, utility model or designTechnical changes reserved - 3 -About this operating manual Series FMG90- 4 - M-5204/06150 About this operating manual• The operating manual is aimed at specialists and semi-skilled personnel.• Before each step, read through the relevant advice carefully and keep to the specified order.•Thoroughly read and understand the information in the section "Safety instructions".If you have any problems or questions, please contact your supplier or contact us directly at:One Omega Drive, P.O. Box 4047Stamford, CT 06907-0047 Tel: (203) 359-1660 e-mail:**************Hazard signs and other symbols used:WARNING! / CAUTION! Risk of injury!This sign indicates dangers that cause personal injuries that can lead to health defects or cause considerable damage to property.CAUTION! Electric current!This sign indicates dangers which could arise from handling of electric current.CAUTION! Material damage!This sign indicates actions which could lead to possible damage to material or environmental damage.ADHERE TO OPERATING MANUAL! NOTICE!This symbol indicates important notices, tips or information. NO DOMESTIC WASTE!The device must not be disposed of together with domestic waste.Pay attention to and comply withinformation that is marked with this symbol.Follow the specified instructions and steps.Adhere to the given order.❑Check the specified points or notices.Reference to another section, document orsource. • Item.Series FMG90 Device descriptionTechnical changes reserved - 5 -1 Device descriptionThe FMG90 series from Omega, is a non-contact flow sensor. The measurement is performed using magnetic induction and works without any moving parts.The FMG90 is used for measuring or metering water and aqueous solutions. The compact design and independence from the intake and discharge sections allows the FMG90 to be used under a variety of conditions.Components:① Sensor housing:The sensor housing consists of plastic and has the IP65 degree of protection.② Electrical connection:The electrical connection is made via 4-pin plug M12x1.③ Operation / flow indicator LED.④ Type plate with flow direction (marking)⑤ Process connection:The process connections are available in different sizes.Versions: The FMG90 is available with different inner diameters from 0.118 to 0.98 in..The versions can be configured differently ( FMG90 Data sheet).Scope of delivery and accessories:Before installing the device, check that the delivered items and ordered accessories:Scope of delivery:❒1x FMG90 as ordered.❒ 1x Operating manual. ❒ 1x Packaging.Device descriptionSeries FMG90- 6 - M-5204/0615Accessories:❒ Connection cable with moulded M12x1 couplingsocket.❒ M12x1 coupling socket as component.1.1 Intended useThe magnetic inductive flow sensor FMG90 must only be used for measuring and metering liquids with a minimum conductivity of 20 μS/cm.WARNING! No safety component!The magnetic inductive flow sensor of the series FMG90 are not safety components in accordance with Directive 2006-42-EC (Machine Directive). Never use the FMG90 as a safety component.The operational safety of the device supplied is only guaranteed by intended use. The specified limits (♑ § 9 "Technical data") may under no circumstances be exceeded.Before installing the device, check that the wetted materials of the device are compatible with the media being used (♑ § 9.2 "Materials table").Measuring tube empty (or partially filled). / Conductivity too low.The green LED may blink irregularly if the measuring tube of the FMG90 is empty or partially filled or if the conductivity of the fluid being used is too low. Random pulses will be present at the output, but they do not represent an actual flow.Ensure that the measuring tube of the FMG90 is always completely filled (♑ § 4.1 "Installation instructions").Ensure that the conductivity of the fluid is at least 20 μS/cm.1.2Exclusion of liabilityWe accept no liability for any damage or malfunctions resulting from incorrect installation, inappropriate use of the device or failure to follow the instructions in this operating manual.Series FMG90 Safety instructionsTechnical changes reserved - 7 -2Safety instructionsBefore you install the FMG90, read through this operating manual carefully. If theinstructions contained within it are not followed, in particular the safety guidelines, this could result in danger for people, the environment, and the device and the system it isconnected to.The FMG90 correspond to the state-of-the-art technology. This concerns the accuracy, the operating mode and the safe operation of the device.In order to guarantee that the device operates safely, the operator must act competently andbe conscious of safety issues.Omega provides support for the use of its products either personally or via relevant literature. The customer verifies that our product is fit for purpose based on our technical information. The customer performs customer- and application-specific tests to ensure that the product is suitable for the intended use. With this verification all hazards and risks are transferred to ourcustomers; our warranty is not valid.Qualified personnel:The personnel who are charged for the installation, operation and maintenance of the FMG90 must hold a relevant qualification. This can be based on training or relevanttuition.The personnel must be aware of this operating manual and have access to it at all times.The electrical connection should only be carried out by a fully qualified electrician. General safety instructions:In all work, the existing national regulations for accident prevention and safety in the workplace must be complied with. Any internal regulations of the operator must also be complied with, even if these are not mentioned in this manual. Degree of protection according to EN 60529:Please ensure that the ambient conditions at the site of use does not exceed the requirements for the stated protection rating (§ 9 "Technical data").Only use the FMG90 if it is in perfect condition. Damaged or faulty devices must be checked without delay and, if necessary, replaced.When fitting, connecting and removing the FMG90 use only suitable appropriate tools. Do not remove or obliterate type plates or other markings on the device, as otherwise the warranty is rendered null and void. Special safety instructions:(Further) Warnings that are specifically relevant to individual operating procedures or activities can be found at the beginning of the relevant sections of this operating manual.Construction and function Series FMG90- 8 - M-5204/06153 Construction and functionConstruction:The measuring tube with its earthing sleeves and electrodes passes through the sensor housing and forms the external process connection of the FMG90.A magnetic field for the measurement process is generated inside the sensor housing, which also contains the sensor and signal conditioning circuitry.The two stainless steel electrodes are located in the middle of the measuring tube between the earthing sleeves. The FMG90 does not need any moving parts to make measurements. The inside of the measuring tube is completely open, allowing the fluid to flow unhindered through the measuring tube.Function:The magnetic inductive flow sensor functions according to the induction principle: The measuring tube is located in a magnetic field (B). If an electrically conductive medium (V) flows through the measuring tube and, therefore, at right angles to the magnetic field, a voltage (U) which is proportional to the mean flow velocity will be induced in the medium and subsequently picked up by the two electrodes.4 Installation of FMG90Before installing, check that❒ the wetted materials of the device are suitable for the media being used ( § 9.2"Materials table").❒the equipment is switched off and is in a safe and de-energized state. ❒ the equipment is depressurized and has cooled down.SUITABLE TOOLS:Use only suitable tools of the correct size.Series FMG90 Installation of FMG90Technical changes reserved - 9 -4.1 Installation instructionsCAUTION!Risk of malfunction due to external magnetic fields!Magnetic fields close to the device can cause malfunctions and should be avoided.Ensure that no external magnetic fields are present at the installation site of the FMG90.•The FMG90 can always be installed anywhere along the pipeline. Straight sections of piping are preferable, however.•Installation can occur in horizontal and vertical pipes. The flow sensor is only suitable for application in completely filled pipe systems.•As a matter of principle magnetic inductive flow sensors are widely independent from the flow profile. An inlet section is not absolutely necessary.To reach a most highly accuracy of the measurement, you should use straight inlet and outlet sections according to the inner diameter. The inlet section has to be at least10 x inner diameter; the outlet section 5 x inner diameter in order to achieve the specified accuracy.•The inlet and outlet sections and the gaskets must have the same or a slightly larger inside diameter than the measuring tube in order to achieve the specified accuracy.Installation of FMG90 Series FMG90- 10 - M-5204/0615•If two or more FMG90 devices are used side by side, maintain a separation of at least 1.0 in between adjacent devices.If adjacent devices are too close together, operation of both devices may be impaired due to mutual interference.4.2 AssemblyThe FMG90 is installed directly into the pipeline. The compact design and light weight of the unit make wall-mounting unnecessary.IMPORTANT NOTICES:• Observe the flow direction indicated on the type plate.• Observe the mounting dimensions (♑ § 9.4 "Dimensions").Select an appropriate location for installation (♑ § 4.1"Installation instructions").To ensure the best possible measuring accuracy, a vertical installation position with increasing flow is preferable (no collecting of dirt deposits).Wrap the FMG90 connections with 1 to 2 wraps of threadtape (e.g. Teflon ® tape). Wrap tape in a clockwise direction, viewed form the end, leaving the first two threads uncovered. Make sure the tape does not intrude into the flow path.Attach the FMG90 with arrow pointed in the direction of flow. The fittings should be screwed into FMG90 hand tight.CAUTION! Material damage!Do not use excessive force. The FMG90 can be damaged.While tightening, counter the FMG90 only by hand! If you use an open-end or a pipe wrench, the FMG90can be damaged.To tighten the FMG90, use an open-end or a pipewrench for the fittings and only the hand for the FMG90. Tighten the FMG90 an additional ¾ to 1 turn.Series FMG90 Electrical connectionTechnical changes reserved - 11 -5 Electrical connectionThe electrical connection of the FMG90 is via the 4-pin plug M12x1 at the top.The corresponding connection cables with moulded coupling socket are available in various lengths included in the range of Omega accessories.CAUTION! Electric current!The electrical connection should only be carried out by a fully qualified electrician. De-energize the electrical system before connecting the FMG90.Connection and wiring:Screw the coupling socket of the connection cable to the plug of the FMG90. Tighten the knurled nut of the coupling socket with a maximum torque of 1 Nm. Connect the connection cables according to the following wiring diagrams. Pin assignment:Pin 1: +U B Pin 3: GNDPin 2 / 4: Frequency output NPN/PNPPin configuration with NPN frequency output:PNP frequency output:Pull-up- / pull-down-resistors R .We recommend using resistors of ~1 kΩ (12V) respectively ~2,2 k Ω (24V) and 0.25 W for the pull-up / pull-down wiring.Please note that the maximum signal current of 25 mA will not be exceeded.Commissioning and measuring operation Series FMG90- 12 - M-5204/06156 Commissioning and measuring operationBefore switching on the FMG90 for the first time, please follow the instructions in the following section.6.1 CommissioningCheck that❒ the FMG90 has been installed correctly and that all screw connections are sealed. ❒ the electrical wiring has been connected properly. ❒ the measuring system is vented by flushing.Switch on the supply voltage.The red LED lights permanently. The FMG90 is ready for use and goes into measuring operation.6.2 Measuring operationThe red LED is constantly lit to indicate that the FMG90 is operational.The green LED blinks according to the frequency of the output signal.This blinking is not perceptible to the human eye at frequencies above 30 to 40 Hz,so the green LED appears to be constantly lit. Frequency output:The frequency output provides a flow-proportional PNP/NPN square wave signal.7 Maintenance and cleaningMaintenance:The FMG90 is maintenance-free and cannot be repaired by the user. In case of a defect, thedevice must be replaced or sent back the manufacturer for repair.CAUTION! Material damage!When opening the device, critical parts or components can be damage. Never open the device and perform any repair yourself.Cleaning:Clean the FMG90 with a dry or slightly damp lint-free cloth. Do not use sharp objects or aggressive agents for cleaning.Series FMG90 Disassembly and disposalTechnical changes reserved - 13 -8 Disassembly and disposalCAUTION! Risk of injury!Never remove the device from a plant in operation.Make sure that the plant is shut down professionally.Before disassembly:Prior to disassembly, ensure that❒ the equipment is switched off and is in a safe and de-energized state. ❒ the equipment is depressurized and has cooled down. ❒Disassembly:Remove the electrical connectors.Remove the FMG90 using suitable tools. ❒ Disposal:NO HOUSEHOLD WASTE!The FMG90 consists of various different materials. He must not be disposed of with household waste.Take the FMG90 to your local recycling plant orsend the FMG90 back to your supplier or toOmega.Technical data Series FMG90- 14 - M-5204/06159 Technical dataThe technical data of customized versions may differ from the data in these instructions. Please observe the information specified on the type plate.9.1 Characteristics FMG90** other pulse rate / resolution on request.optional: Output signal with lower frequency, designed specifically for connection to digital PLC inputs.Series FMG90 Technical dataTechnical changes reserved - 15 -9.2 Materials table9.3 Pressure dropTechnical data Series FMG90- 16 -M-5204/06159.4 DimensionsFMG 91 … FMG 99:FMG 96:Series FMG90 For your notes For your notesTechnical changes reserved - 17 -For your notes Series FMG90 For your notes- 18 - M-5204/0615Series FMG90Technical changes reserved - 19 -Series FMG90M-5204/0615 - 20 - M-5204/0615。

OPTIFLUX 系列 电磁流量计 说明书

OPTIFLUX 系列 电磁流量计 说明书

OPTIFLUX 系列及其它技术数据表电磁流量计OPTIFLUX 1300 / 2300 / 4300 / 5300 / 6300 电磁流量计,拥有强大的自诊断功能,有各种安装接口,有各种衬里和电极材料,最高精度可达0.15%,重复性0.06% OPTIFLUX 2100 / 4100 电磁流量计(IFM 4080 升级换代产品,有自诊断功能)K300 一体型电磁流量计/ K 450K + F 电磁流量计高压电磁流量计科隆电磁流量计经济型K 300(一体型)模拟量K 450(一体或分体型)模拟量(带显示)特殊型OPTIFLUX 4040 C 两线制TIDALFLUX 4110 PF 非满管BATCHFLUX 5015 C 灌装式卫生型常用型W FOPTIFLUX 6300 C1. 性能简介1- 52. 常用产品2.1 OPTIFLUX 2300 / 4300 电磁流量计62.1 .1I FC 300 信号转换器6- 162.2 OPTIFLUX 2100 / 4100 电磁流量计172.2 .1I FC 100 信号转换器17- 2021- 22232425263. 经济型30- 313 .2K450K + F 电磁流量计32- 334. 选型与安装4.1传感器口径选择34- 354 .2电极形式 / 材料选择364.3衬里材料的选择374.4传感器在管线上的安装38- 416. 原理及标定证书44目录2.3 OPTIFLUX 2000/4000传感器2.4 IFS / 4000-HP 高压传感器2.5 IFM 3100K +F 电磁流量计2.6 OPTIFLUX 1300夹持型电磁流量计2.7 OPTIFLUX 5300 S W 陶瓷型夹持式电磁流量计2.7.1 OPTIFLUX 5300 FL 法兰型272.8 OPTIFLUX 6300 卫生接口型电磁流量计28- 293.1 K 300 一体型电磁流量计5. 产品选型编码42- 431. 性能简介OPTIFLUX 2300 / 4300 W(可选 C + F + R)DN 10 ~ 3000OPTIFLUX (一体)(墙挂分体)2100 / 4100 C + W DN 10 ~ 1200详细数据见P 6详细数据见P 17OPTI FLUX 2000(橡胶)/ OPTI FLUX 4000(四氟、PFA )+ / -0.3%±1mm / s (取决于传感器)OPTI FLUX 2000(橡胶)/ OPTI FLUX 4000(四氟、PFA )0.2% - 0.3%(液体中最多含30% 的固体成份)IFM 3100 / 3300 C + W1. 性能简介仪表性能同OPTIFLUX4100,传感器见M 900,见P 24K 300DN 10 ~ 300K 300≤1%详细数据见P 30DN 50 ~ 300M 900+ / -0.3% ±1mm / s(取决于传感器)K 4501. 性能简介DN 10 ~ 450 IFS4000≤0.5%DN 10 ~ 150 OPTIFLUX 1300 OPTIFLUX 10000.3%1. 性能简介OPTIFLUX 5300OPTIFLUX 63001. 性能简介OPTIFLUX 4040TIDALFLUX 4110 PFIFC 300 信号转换器1 图形显示器,背光(白)2 第1 行和第2 行用于显示不同的测量变量,大字体格式显示时只显示一个变量3 第三行显示条形图4 光感应键,无需打开盖就可操作信号转换器5 蓝色条显示:·测量模式时显示仪表位号·设置模式时显示菜单/ 功能名称6 X 指示有键按动7 指示红外线输出工作,此时4 光感应键失效8 连接KROHNE GDC 总线的插座9 光电感应接口,用于无线传送数据(输入/ 输出)IFC 300 显示 / 操作和调整键IFC 300 C 和IFC 300 F 的o 显示器可以隔90旋转2.1 IFC 300 信号转换器2.1 IFC 300 信号转换器使用特点·工厂设置(有二个记忆芯片,一个在机内,另一个在机芯外的底板上)·可以存储3组设定数据,factrory settings 为工厂设定数据用户不能更改(传感器的GK 值、满量程、零点、线圈阻值、温度等)机外底板上的记忆芯片机内记忆芯片·更换转换器时无需设置数据,直接从机芯外的底板上取出工厂设定数据。

电磁流量计(上海光华)

电磁流量计(上海光华)

D ——测量管内径;
B ——磁感应强度; V ——平均流速;
K ——与磁场分布及轴向长度有关的系数;
图 1 工作原理图 —1—
3、性能简介
光 华 电 磁 流 量 计
口径 电极材料
内衬材料
介质 介质电导率 配套精确度等级 流速范围 工作温度
工作压力 工换器型号
输出信号
通迅接口 防爆等级 适用电源
(聚氨酯 ≤45℃) 4.0MPa~0.6MPa(按口径分) ≤0.25A 标准型IP65(防喷水) 特殊型 IP67(防浸水) __
0~10mA DC 或 4~20mA DC 上限 1-5000Hz (上限 5000CP/S)
瞬时流量、累积流量(正、反向积算量及积算差) 流速、百分比、电导比、报警指示、故障诊断
* RS485、RS232C (配LDZ-6型)
220V 50Hz
* 24V DC(配LDZ-6型)
酸碱等腐蚀液;矿浆、泥浆、纸浆等两相液; 给排水系统 机标JB/T81-94 (口径250~1200) 国标GB9119-88(口径10~200) 或按用户需要 QYXYS 13-2002 一体式
光 华 电 磁 流 量 计
LDY-S系列一体型电磁流量计由LDG-S型电磁流量传感器和转换器配套组成一体,口径从10mm至 1200mm,其结构紧凑、安装方便、测量精度高、抗干扰性好。
LDG-/ K型高压电磁流量计专门用于石油勘探、地质或油田系统测量高压条件下的泥浆、高压注水等 介质的体积流量。
LDQ潜水型电磁流量计是国家环保局推荐使用的污水排放用明渠流量仪表。 光华仪表厂本着“精益求精,创造一流”的企业精神,已连续十几年被评为“上海市高新技术企业”。一 九九七年通过ISO9001质量体系认证。

上海肯特电磁流量计

上海肯特电磁流量计

选择此功能,可进行仪表总量清零操
2
总量清零

选择此功能,可进行查看流量系数修
3
系数更改记录
改记录
Page 4 of 17
仪表现场服务规范
版本号: P0 日期: 2012-6-15
4.参数设置
按一下“复合键 + 确认键”显示“参数设置”功能,仪表进入到功能选择画面“参数设置”,然后按 确认键进入输入密码状态,“00000”状态,输入密码进入按一下“复合键 + 确认键”进入参数设 置画面。
00000~99999
5
42 反向总量高位 可以修改
0000~9999
5
43 尖峰抑制允许
选择
允许/禁止
5
44
尖峰抑制系数
选择
0.010~0.800m/s
5
45
尖峰抑制时间
选择
400~2500ms
5
Page 6 of 17
仪表现场服务规范
版本号: P0 日期: 2012-6-15
46
保密码 1
用户可改
2
1~50(6)
2
正向、反向
2
0~±9999(0)
2
0~599.99%
2
允许/禁止
2
0.001m3~1m3 、0.001L~1L、
2
允许、禁止
2
Page 5 of 17
仪表现场服务规范
版本号: P0 日期: 2012-6-15
14 电流输出类型
选择
0~10mA /4~20mA
2
15 脉冲输出方式
选择
仪表设计有 6 级密码,其中 4 级用户可以自行设置密码值,最高 2 级为固定密码值,6 级密 码分别用于不同保密级别的操作者。

电磁流量计mag6000

电磁流量计mag6000

■简介MAG 5000/6000一体式(左)和19"插入式(右)变送器MAG 5000和6000是基于微处理器的高性能变送器,易于安装、调试和维护。

变送器可与MAG1100,MAG1100F,MAG3100,MAG3100W 和 MAG5100W SITRANS F M MAGFLO传感器配套使用。

变送器类型:• MAG5000:最大测量误差0.5%(包括传感器)。

• MAG6000:最大测量误差0.25%(包括传感器,参见传感器说明书),具有其它特性如:即插即用式内置总线模块;批处理功能。

■特性• 信号分辨率高,可达最佳量程比• 多种可能性的数字信号处理• 自动从SENSORPROM中读取数据,易于调试• 具有密码保护的用户组态操作菜单• 3行,20个字符,11种语言显示• 各种流速单位• 累计流量,正向、反向流量和净流量以及其它更多信息• 用于过程控制的多功能输出,具有模拟、脉冲/频率和继电器输出 (状态、流向和极限值)的最小组态• 丰富的自诊断功能,出错指示和故障记录 (参见MAGFLO诊断功能)• 批控制• 贸易结算认证:PTB,OIML R75,R117,R49• MAG 6000 具有附加的总线模块:HART,MODBUS RTU/RS485,PROFIBUS PA和DP,CANOpen,DeviceNet ■应用MASGFLO流量计适合于测量几乎所有的导电液体、淤泥和泥浆的测量。

主要应用于以下领域:• 水工业和污水处理• 化工和制药工业• 食品和饮料工业• 发电厂和民用电■设计变送器设计为IP67 NEMA 4X/6防护等级的一体式,或者墙装式,或基于19″插入式结构的19″型,用于:• 19″架装系统• 盘装支架IP65/NEMA 4• 盘后安装IP20/NEMA 2• 墙装支架IP66/NEMA 419″型可有以下几种选择:• 适于EEx ATEX 认证的流量传感器的变送器(包括安全栅)• 带电极清洗单元的变送器■功能MAG 5000/6000是基于微处理器的变送器,带有内置的字母数字式多种语言的显示器。

ABB 电磁流量计中文说明书

ABB 电磁流量计中文说明书
2.1 综述 .................................................................................................................................................................................................................... 7 2.2 可重复性,响应时间 ........................................................................................................................................................................................... 7 2.3 变送器 .............................................................................................................................................................................................................. 7 2.4 流量计口径,流量范围 ................................................................................................................................................................................... 8

LRF-3000P 超声波流量计使用说明书

LRF-3000P 超声波流量计使用说明书

前言感谢您购买本公司产品!本手册是关于仪表的功能、设置、接线方法、故障处理等的操作的说明书。

在操作前请仔细阅读本手册,以便正确使用仪表。

在您阅读完后,请妥善保管在便于翻阅的地方,以便操作时参照。

注意本手册内容因功能升级等修改,恕不通知。

关于本手册内容经过仔细校对,如果您发现有不妥或错误之处,请与仪表的销售商联系。

如实物与本手册内容有出入,以实物为准。

本书内容严禁全部或者部分转载、复制。

版本2020-10.1警告为了您的安全,请在使用仪表前认真阅读以下安全警告。

目录1.1产品责任和质保 (2)1.2对操作者的安全指导 (3)第二章仪表说明 (4)2.1交货范围 (4)2.2测量原理 (6)2.3应用范围 (6)2.4铭牌 (7)第三章电气连接 (8)3.1安全提示 (8)3.2用于仪表的电气电缆 (9)3.3连接电气电缆 (10)3.4变送器接线 (11)第四章操作面板及快速启动 (12)4.1开启电源 (12)4.2开机画面 (12)4.3键盘操作 (14)4.4快速启动 (17)第五章安装 (20)5.1安装、存放及提示 (20)5.2管路设计及选择 (21)5.3传感器的安装 (24)第六章操作 (31)6.1常用功能说明 (31)6.2操作菜单说明 (35)6.3菜单组态说明 (37)第七章常见故障问题分析 (51)第八章通讯接口和通信协议说明 (52)附录.测量相关数据库 (60)版权和数据保护本文档的内容已经经过认真检查并不保证内容完全正确并与最新版本的文档内容完全一致。

本文档的内容及作品受到中国版权法律的保护。

未经本公司的事先书面许可,本仪表的任何部分包括源代码,不得以任何形式或电子、电磁、光学、人工或其它的任何方式,复制、传输、转录或翻译成任何一种语言或计算机语言。

未经本公司的事先书面许可,本手册的全部或部分不得复制、影印、转载、翻译或传输到任何电子或可机读媒体上。

此处产品上显示的名称和标志是本公司的注册商标或商标。

开流 MGG KL-CC 型 插入式电磁流量计 安装使用说明书

开流 MGG KL-CC 型 插入式电磁流量计 安装使用说明书

MGG/KL-CC型插入式电磁流量计安装使用说明书通过ISO9001.2000质量体系认证豫制02000031号开封开流仪表有限公司目录插入式电磁流量计 (3)1.概述 (3)2.用途和适用范围 (3)3.产品的型式和组成 (3)4.主要技术性能 (4)5.工作原理及结构 (4)6安装和使用 (6)7.维护、修理和常见故障排除 (10)8开箱与产品成套性 (10)9订货须知 (11)10保用期内供需双方应负责任 (11)插入式电磁流量计1.概述MGG/KL-CC型插入式电磁流量传感器(简称传感器)和MGG/KL-CC型插入式电磁流量转换器(简称转换器)配套成MGG/KL-CC型插入式电磁流量计(简称流量计)用来测量输送管道内各种导电液体的体积流量。

2.用途和适用范围传感器具有以下特点:◆传感器内无活动部件,结构简单,工作可靠。

◆插入式电磁结构可在低压或带压情况下不停水方便的安装、拆卸。

因此非常适用于现有管道的流体测量和便于仪表的维护、修理。

◆测量精度不受被测介质的温度、压力、密度、粘度、电导率(只要电导率大于20µs/cm)等物理参数变化的影响。

◆传感器几乎无压力损失,能量损耗极低。

◆较一般流量计的制造成本和安装费用低。

特别适于大中径管道流量测量。

◆采用先进的低频方波励磁。

零点稳定,抗干扰能力强,工作可靠。

◆流量测量范围大。

被测量管道内的满量程流速可以1m/s至10m/s任意设定,输出信号与流量呈线性关系。

◆流量计不仅有0~10mA◆DC或4~20mA◆DC标准电流输出,同时还1~5kHz频率输出◆双向正反量计量。

由于流量计(传感器)具有上述一系列优点,因而,已被广泛应用于化工、化纤、冶金、化肥、造纸、给排水、污水处理等工业部门和农业灌溉水计量的导电液体流量测量和生产过程的自动控制。

.3.产品的型式和组成产品的型式为插入式,与管道通过安装底座、球阀和压紧螺母、定位螺钉连接。

传感器测量分测量管型和平面电极型两种结构型式。

Georg Fischer 2552 电磁流量计 操作手册说明书

Georg Fischer 2552 电磁流量计 操作手册说明书

Georg Fischer的Signet 2552金属电磁流量计采用全不锈钢结构。

PVDF末端和FKM O形圈是唯一的其他接液材料。

2552可快速安装到标准的1¼英寸或1½英寸管道出口中,并可调节以适合DN50至DN2550(2至102英寸)的管道。

两种传感器长度提供了最大的灵活性,以适应各种硬件配置,包括用于hot-tap安装的球阀。

当配备为频率输出时,2552可与任何Signet流量仪表兼容,而S³L数字输出则可与Signet 8900多参数流量控制器实现多通道兼容。

选择盲4-20mA电流输出,可直接与数据采集器,PLC或遥测系统连接。

主要功能包括空管检测,LED辅助故障排除和双向量程(4-20mA型号)。

Signet 3-0252配置工具可用于自定义2552中的每个功能,因此可以根据用户的应用要求进行调整。

*3-2552.090*3-2552.090 Rev. 8 10/19Signet 2552 电磁流量计中文操作说明书目录3-2552-33-2552-2质保信息 .................................................................................................................2产品注册 .................................................................................................................2安全信息 .................................................................................................................2环境建议 .................................................................................................................2产品规格 ............................................................................................................2-3尺寸 .........................................................................................................................4概况 .........................................................................................................................4位置选择 .................................................................................................................4安装的一般要求 ....................................................................................................4安装于竖直管道 ....................................................................................................5安装于水平管道 ....................................................................................................5传感器调节 .............................................................................................................5接地 .........................................................................................................................5安装准备 .................................................................................................................6H-尺寸 ....................................................................................................................6安装电磁流量计 ...............................................................................................7-8频率输出接线 .........................................................................................................9数字(S³L)输出接线 ...................................................................................9-104-20mA回路输出接线 ......................................................................................10校准数据 .......................................................................................................11-12技术支持 ..............................................................................................................13故障排除 ..............................................................................................................14维护 ......................................................................................................................14选择传感器 ..........................................................................................................15订货信息 .. (16)2Signet 2552 电磁流量计该设备符合FCC规则的第15部分。

AXF电磁流量计流量管可选规格

AXF电磁流量计流量管可选规格

垫片:氯丁橡胶
螺栓:JIS SUS304 (或AISI 304 SS不锈钢); 螺母:JIS SUS403 (或AISI 403 SS不锈钢); 垫片:非石棉PTFE铠装
专用垫片(*3)
PFA 衬套或陶瓷衬里的PVC管使用Viton® 垫片。Valqua #4010, 不掺入特殊 的氟化橡胶。适用于2.5 mm (0.1 in.)~200 mm (8.0 in.)。
PFA 衬套或陶瓷衬里的PVC管使用防酸Viton® 垫片。Valqua #4010, 掺入特 殊的氟化橡胶(掺入#RCD470)。适用于2.5 mm (0.1 in.)~200 mm (8.0 in.)。
PFA 衬套或陶瓷衬里的PVC管使用防碱Viton® 垫片。Valqua #4010, 掺入特 殊的氟化橡胶(掺入#RCD970)。适用于2.5 mm (0.1 in.) ~ 200 mm (8.0 in.)。
螺栓、螺母和垫片 (*2) 夹持型连接提供螺 螺栓和螺母:碳钢、垫片:氯丁橡胶
栓、螺母和垫片。
仅适用于ANSI 150, 螺栓和螺母:碳钢、垫片:表面覆PTFE的非石棉垫片
JIS10K或JIS20K夹
持型连接。
螺栓:JIS SUS304 (或AISI 304 SS不锈钢);
螺母:JIS SUS403 (或AISI 403 SS不锈钢);
环氧树脂涂层
采用环氧树脂而不是标准聚氨脂包层。颜色与标准类型相同。
X1
高强防腐涂层
如标准包层一样的三层包层(一层聚氨酯层和两层环氧树脂层)颜色与标准类 型相同。防盐/碱/酸性环境。
材料证明
重新给出下列材料认证: PFA/聚氨酯: 管道、电极、接地环/接地电极、小法兰(夹持型)、法兰(法兰 型)陶瓷:仅用于接地环或接地电极

WRFLZ-2900电磁流量计(4P)

WRFLZ-2900电磁流量计(4P)

WRFLZ-2900系列电磁流量计是采用西门子先进技术,其电磁转换器内核采用高速中央处理器,运算速度快、测量精度高、量程比宽、操作简单方便、测量稳定可靠,测量不受液体密度、粘度、温度、压力等影响,管道内无任何可动部件,无阻流部件,具有自检和自诊断功能,全数字量处理,抗干扰能力强,是目前流量仪表中的性价比极高的一款产品,主要用于测量管道中导电液体的体积流量,如水、污水、泥浆、矿浆、酸、碱、盐液体及食品浆液等。

在化工化纤、冶金、制糖、造纸、煤炭、水利工程给排水、环保、自来水、污水处理等行业中广泛应用。

本公司生产的电磁流量计有三种:一体式、分体式和插入式。

工作原理WRFLZ-2900系列电磁流量计所依据的基本理论是法拉第电磁感应定律。

当导体切割磁力线运动时,导体内将产生感应电动势。

根据该原理,可测量管内流动的导电流体的体积,如图所示,导电流体流动的方向与电磁场的方向垂直,在导管垂直方向施加一个交变的磁场,并在有绝缘衬里的导管内壁两侧安装一对电极,两电极的连线既与导管轴线垂直,又与磁场方向垂直,当导电液体流经导管时,因切割磁力线,两个电极上就产生感应电动势UE。

■技术参数:测量精度:0.5级,1.0级重复性:±0.2%量程比:1:10~1:20供电电源:220V AC±10%,24VDC±10%可选显示方式:LCD背光液晶双排显示,可中英文切换显示,可同时显示瞬时流量及正向累计流量、反向累计流量、净累计流量、流速、仪表状态、时间等数据;操作:4位组合轻触键盘,操作简单方便信号输出:模拟输出:隔离型4-20mA或0-20mA模拟量输出;继电器:用于上、下限报警信号输出控制频率输出:0-2KHz通讯输出:RS-485、 RS-232、Hart协议、Modbus协议、Profibus协议流速范围:0.3~±10m/s介质流向:具有正、反向计量测量管径:四氟衬里:DN10~DN600橡胶衬里:DN40~DN2000介质温度:橡胶衬里:-20~80℃电导率范围:被测流体电导率直连接方式:法兰连接 防爆等级:Exd ⅡBT4防护等级:常规型 IP67潜水型IP68■主机外形尺寸■电极、接地环材质的选择应根据被测流体的腐蚀性来选择电极的材料,请查有关腐蚀手册,对于特殊流体应做试验。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

WRFLZ-2900系列电磁流量计是采用西门子先进技术,其电磁转换器内核采用高速中央处理器,运算速度快、测量精度高、量程比宽、操作简单方便、测量稳定可靠,测量不受液体密度、粘度、温度、压力等影响,管道内无任何可动部件,无阻流部件,具有自检和自诊断功能,全数字量处理,抗干扰能力强,是目前流量仪表中的性价比极高的一款产品,主要用于测量管道中导电液体的体积流量,如水、污水、泥浆、矿浆、酸、碱、盐液体及食品浆液等。

在化工化纤、冶金、制糖、造纸、煤炭、水利工程给排水、环保、自来水、污水处理等行业中广泛应用。

本公司生产的电磁流量计有三种:一体式、分体式和插入式。

工作原理
WRFLZ-2900系列电磁流量计所依据的基
本理论是法拉第电磁感应定律。

当导体切割磁力
线运动时,导体内将产生感应电动势。

根据该原
理,可测量管内流动的导电流体的体积,如图所
示,导电流体流动的方向与电磁场的方向垂直,
在导管垂直方向施加一个交变的磁场,并在有绝
缘衬里的导管内壁两侧安装一对电极,两电极的
连线既与导管轴线垂直,又与磁场方向垂直,当
导电液体流经导管时,因切割磁力线,两个电极
上就产生感应电动势UE。

■技术参数:
测量精度:0.5级,1.0级
重复性:±0.2%
量程比:1:10~1:20
供电电源:220V AC±10%,24VDC±10%可选
显示方式:LCD背光液晶双排显示,可中英文切换显示,可同时显示瞬
时流量及正向累计流量、反向累计流量、净累计流量、流
速、仪表状态、时间等数据;
操作:4位组合轻触键盘,操作简单方便
信号输出:模拟输出:隔离型4-20mA或0-20mA模拟量输出;
继电器:用于上、下限报警信号输出控制
频率输出:0-2KHz
通讯输出:RS-485、 RS-232、Hart协议、Modbus协议、Profibus协议
流速范围:0.3~±10m/s
介质流向:具有正、反向计量
测量管径:四氟衬里:DN10~DN600
橡胶衬里:DN40~DN2000
介质温度:橡胶衬里:-20~80℃
电导率范围:被测流体电导率直连接方式:法兰连接 防爆等级:Exd ⅡBT4
防护等级:常规型 IP67
潜水型
IP68
■主机外形尺寸
■电极、接地环材质的选择
应根据被测流体的腐蚀性来选择电极的材料,请查有关腐蚀手册,对于特殊流体应做试验。

电极材料 代码 耐腐蚀性能
316L M
硝酸、室温下<5%硫酸、沸腾的磷酸、蚁酸、碱溶液、在一定压力下的亚硫酸、海水、醋酸
哈氏合金C 哈氏合金B (HB 、HC )
HC HB
耐氧化性酸、氧化性盐、耐海水、耐非氧化性酸、非氧化性盐、碱、常温硫酸
钛(Ti ) Ti 海水、各种氯化物和次氯盐酸、氯化性酸(包括发烟硝酸)、有机酸、
碱 钽(Ta ) Ta 除氢氟酸、发烟硫酸、碱外的其余化学介质、包括沸点的盐酸。

硝酸和<175℃硫酸 铂(Pt )
Pt
各种酸、碱、盐、不包括王水
■衬里材料的选择
应根据被测介质的腐蚀性、磨损性和温度来选择内衬材料。

内衬材料名称符号性 能 工作温度适用液体
氯丁橡胶 耐磨性中等,耐一般低
浓度的酸碱盐的腐蚀
<80℃
自来水、工业用水、
海水
橡胶
聚胺脂橡胶 极好的耐磨性能,耐酸
碱性能较差
<60℃ 纸浆、矿浆等浆液
聚四氟乙烯 PTFE -40℃~150℃ 氟塑料
改性聚四氟乙烯 PFA
塑料中化学性能很稳定
的一种材料,能耐沸腾
的盐酸、硫酸、王水、
浓碱的腐蚀
-40℃~200℃
腐蚀性强的酸、碱、
盐液体
■流量范围
最大流量和最小流量必须符合下表中的数。

内径(mm)10 15 20 25 32 40 50 65
Qmin(m3/h) Qmin(m3/h) 0.0283
4.24
0.0636
9.54
0.12
16.96
0.176
26.5
0.29
43.42
0.452
67.85
0.7
106.0
1.19
179.0
内径(mm)80 100 125 150 200 250 300 350
Qmin(m3/h) Qmin(m3/h) 1.8
271.0
2.28
424.0
4.41
662.0
6.36
954.0
11.3
1690
17.6
2650
25.4
3810
34.6
5190
内径(mm)400 450 500 550 600 700 800 900
Qmin(m3/h) Qmin(m3/h) 45.2
6780
57.2
8570
77.6
10600
85.8
12800
101.0
15200
138.0
20700
180.0
27100
229.0
34300
内径(mm)1000 1100 1200 1400 1600 1800 2000 2200
Qmin(m3/h) Qmin(m3/h) 282.0
42400
342.0
51300
407.0
61000
554.1
83121
732.7
108566
916.0
137404
1131.0
169635
1368.4
205258
■安装要求
为了正确的测量,在选择管道上位置时应注意以下几点要求:
(1)传感器既可在垂直管道上安装,也可以在水平或倾斜管道上安装,但要求二电极的中心连线处于水平状态;
(2)介质在安装位置应该保证满管流动,避免不满管及气体附着在电极上;
(3)对于液固两相流体,最好采用垂直安装,使被测传感器衬里磨损均匀,延长使用寿命;
(4)流量计安装位置介质不满管时,可采取抬高管道或做U型管路方法,使其满管;
(5)直管段要求:流量计前端≥5DN, 后端≥2DN(D指管道公称通径);
(6)流量计要安装在水泵后端,决对不能安装在抽吸侧安装,阀们应安装在流量计的下游;
(7)尽量避开强磁场的设备,以免影响流量计的传感器工作磁场和流量信号。

■选型编码说明
型谱说明
WRFLZ-2900□ □ □ □ □ □ □ □ 智能电磁流量计
Y 一体式
主机样式
K 分体式
C 插入式
测量管径DN DN10mm-DN2000mm
M 316L
HB 哈氏合金B
HC 哈氏合金C 电极材料
Ti 钛电极
Ta 钽电极
Pt 铂电极
X 氯丁橡胶
衬里材料
F4 聚四氟乙烯
F46聚全氟乙烯
1 4-20mA输出
2 继电器输出
输出方式
3 RS-485输出
4 MODBUS输出
5 Hart 输出
A 220VAC
供电电源
D 24VDC
压力等级 PN0.6MPa 1.0MPa 1.6MP 2.5MPa
L1 标配5米(分体)信号电缆
LN 订货注明(分体)举例:WRFLZ-2900Y-200-M-X-1-A-1.0-400
解释:电磁流量计:一体式,220VAC供电,管径DN200mm,电极316L,橡胶衬里,压力1.0MPa, 4-20mA模拟量输出,流量范围400m3/h。

相关文档