VISHAY-MKC1862

合集下载
相关主题
  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

Document Number: 26027For technical questions contact; dc-film@

MKC 1862

Not for new designs

Vishay Roederstein

Metallized Polycarbonate Film Capacitor

Related Document: IEC 60384-6

MAIN APPLICATIONS Storage, filter, timing and integrating circuits.

MARKING

Manufacturer's logo/type/C-value/rated voltage/tolerance/date of manufacture

DIELECTRIC

Polycarbonate film

ELECTRODES Vacuum deposited aluminum

COATING

Flame retardant plastic case (UL-class 94 V-0), red, epoxy resin sealed

CONSTRUCTION Extended metallized film (refer to general information)LEADS

Tinned wire

IEC TEST CLASSIFICATION

55/100/56, according to IEC 60068

OPERATING TEMPERATURE RANGE

- 55°C to + 100°C

CAPACITANCE TOLERANCES

± 20% (M), ± 10% (K), ± 5% (J)

RATED VOLTAGES (U R )

63 VDC, 100 VDC, 250 VDC, 400 VDC

FEATURES

Product is completely lead (Pb)-free.Product is RoHS compliant.

DERATING FOR DC AND AC. CATEGORY VOLTAGE U C

At + 85°C: U C = 1.0 U R At + 100°C: U C = 0.8 U R CAPACITANCE RANGE

0.01µF to 10µF

PERMISSIBLE AC VOLTAGES (RMS) UP TO 60HZ

40 VAC, 63 VAC, 160 VAC, 200 VAC TEST VOLTAGE (ELECTRODE/ELECTRODE)1.6 x U R for 2 s

INSULATION RESISTANCE

Measured at 100 VDC (63 VDC series measured at 50 VDC) after one minute

For C ≤ 0.33µF and U R > 100 VDC:

30,000 M Ω minimum value (100,000 M Ω typical value)For C ≤ 0.33µF and U R ≤ 100 VDC:

15,000 M Ω minimum value (50,000 M Ω typical value)

TIME CONSTANT

Measured at 100 VDC (63 VDC series measured at 50 VDC) after one minute

For C > 0.33µF and U R > 100 VDC:

10,000 s minimum value (40,000 s typical value)For C > 0.33µF and U R ≤ 100 VDC:

5000 s minimum value (15,000 s typical value)

CAPACITANCE DRIFT Up to + 40°C, ± 1% for a period of two years SELF INDUCTANCE

~ 6 nH measured with 2mm long leads

PULL TEST ON LEADS

≥ 30 N in direction of leads according to IEC 60068-2-21

BEND TEST ON LEADS 2 bends through 90° with half of the force used in pull test RELIABILITY

Operational life > 300,000 h

Failure rate < 1 FIT (40°C and 0.5 x U R )

For further details, please refer to the general information available at /doc?26033.

MAXIMUM PULSE RISE TIME

If the maximum pulse voltage is less than the rated voltage higher dv/dt values can be permitted.

PCM (mm)Maximum Pulse Rise Time d v /d t [V/µs]

63 VDC 100 VDC 250 VDC 400 VDC 101723386115913213322.568132027.5

5

6

10

16

相关文档