自动温湿度控制系统毕业设计

合集下载
  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
本次设计的系统,仅用了一个温度传感器和湿度传感器,显然不能满足实际的运用。现实中应该测量多点的温度和湿度,因此应该多设计几个传感器。这样才能投入到正常的应用中去。
关键字:AT89S52;DS18B20;SHT11;LCD160;非编码键盘
Automatic Temperature And Humidity Control System
Abstract
Communication center is an important place for the installation and operation of equipment, providing equipment with a long-term and reliable operation external environment. These environmental factors include construction, power supply and temperature and humidity environment. For the equipment of communication data center, the best operating environment is 22 ~ 24℃, relative humidity of 35% to 50%, and large changes in temperature and humidity may let sensitive equipment cannot work properly, drastic changes may even lead to equipment damage.
Automatic temperature and humidity control system is based on 51 series MCU AT98S52.The system sets the temperature and humidity at a constant value by the keyboard, and displays of temperature and humidity of these two parameters all the time. System uses a microcontroller as the master chip, first detecting the temperature and humidity through sensors; after A / D converter , the data will be processed within the microcontroller, we can get the corresponding data which is based on algorithm. If temperature is too low, the heater starts heating; if temperature is too low, control hair dryer to cool. Similarly to the control of the humidity which has both humidification and dehumidification equBaidu Nhomakorabeapment.
The designed the system has only a temperature sensor and a humidity sensor, obviously it does not meet the actual use. More realistic temperature and humidity should be measured in, so the design should be more than a few sensors. Only in this way can we put the system into practice.
Keyword:AT89S52;DS18B20;SHT11 ;LCD1602;Encoding Keyboard
插图清单
表格清单
引言
随着电信业的告诉发展,众多的通信枢纽、中继站和基站的建设想雨后春笋一样在各地出现。通信机房是设备安装和运行的重要场所,提供各种设备长期可靠运行的外部条件。这些环境因素主要包括建筑、供电和温湿度的环境等。供电是设备运行安全的首要因素,受到人们的关注;产生和保持适于设备工作的温湿度的环境的重要性和技术方法经常被人们忽视。
自动温湿度控制系统基于51系列的单片机AT98S52,该系统要求通过键盘设置把温度和湿度控制在一个恒定的值,且实时显示温度和湿度这两个参数值。系统采用单片机作为主控芯片,首先通过传感器对温度和湿度进行检测;经过A/D转换将采样到的数据送到单片机内部进行处理后,根据算法得到相应的控制量。如果欠温度,启动加热器加热;如果过温度,控制吹风机冷却。同理,湿度有加湿和去湿装置控制。
自动温湿度控制系统是人们长期研究的对象,尤其是基于单片机的温度控制系统,已经达到非常成熟的地步了。而对于湿度控制系统的研究则相对来说没有这么透彻,因此湿度部分的研究比较的困难。本设计介绍一个通信机房的自动温湿度控制系统研制的实例。该系统主要是基于单片机的,运用最新的数字温度和湿度传感器对温度和湿度进行测量,并且最终根据系统控制的原则来控制空调和风机的开启或者关闭。值得一提的是,本系统采用友好的人机接口实现灵活的机房温湿度的自动控制,具有良好的可靠性和实用性,推广价值较大。
自动温湿度控制系统

通信机房是设备安装和运行的重要场所,提供各种设备长期可靠运行的外部环境。这些环境因素主要包括建筑、供电和温湿度的环境等。对于通信数据中心设备来说,最佳的运行环境是22~24℃,相对湿度在35%~50%之间,温度和湿度的大幅度变化可能导致敏感设备不能正常工作,急剧的温湿度变化甚至可能导致设备的破坏。