防爆阻火呼吸阀
技
术
文
件
湖 北 武 汉 谨 烨 石 化 设 备 有 限 公 司 HUBEI WUHAN INYE PETROCHEMICAL EQUIPMENT CO., LTD. 销售地址Add:湖北.武汉市中山大道100号B 座1402室
工厂地址Add :湖北.武汉经济技术开发区创业路
商务总机Tel :(027)-51350277 51350288
商务传真Fax :(027)-51350299 邮编P.C :430030
网址 E-mail:jinye@
(防爆阻火)呼吸阀
(防爆阻火)呼吸阀是维护储罐气压平衡,减少介质挥发的安全节能产品,常与阻火器配套使用。
Hinder fire breather valve to it maintains to be atmospheric pressure balanced to store pot , reduce the energy-conserving products of security that the medium volatilizes, often use with hindering the firearm together.
我公司生产的(防爆阻火)呼吸阀具有结构紧凑,通气量大、泄漏量小、耐腐蚀等特点。
阀口采用聚四氟材料,具有耐低温、防霜冻等优点。
呼吸阀内设有静电保护装置,使得该阀时刻与罐体保持同等电位。
What our company produce hinder fire breathe valve have structure to be compact , heavy , characteristic light , corrosion-resistant of leaking etc. of keeping in touch with etc.. Port is it gather four Fluorine material to adopt, is it able to bear low temperature , advantage of defending the frost etc. to have. There are static protectors in the valve to breathe , make this valve keep the equal electric potential with the pot body constantly .
我公司是从事石油化工储运设备生产的专业产家,是化学工业部定点企业,并获得中国石化总公司工程建设部重点推荐。
Our company engaged in petrochemical industry warehousing and transportation specialty of device fabrication produce the house, it is a specially-designated factory of Ministry of Chemical Industry, and obtained key recommendation of Ministry of Construction of the project of Chinese Petro-Chemical Corporation. !
一、技术要求:Specification requirement :
操作压力:Operate the pressure:
Type A:+355pa(+36mmH2O) -295pa(-30mmH2O)
Type B:+980pa(+100mmH2O) -295pa(-30mmH2O)
Type C:+1750pa(+180mmH2O) -295pa(-30mmH2O)
Type D:按用户要求生产(特殊压力等级)
Produce according to user's request (the special grade of pressure)
备注:一般情况下,(阻火)呼吸阀的操作压力以B型为准。
适用物料:汽油、煤油、柴油、芳烃、硫、空气等石油化工物料。
环境温度:-30℃-+60℃。
The remarks: Generally speaking , it is subject to B type to hinder the operation pressure of breathing valve of fire. Suitable supplies : Supplies of petrochemical industry , such as petrol , kerosene , diesel oil , aromatic hydrocarbon , sculpture ,
air ,etc.. Environment temperature: -30 degrees Centigrade- +60 degrees Centigrade.
壳体材质:HT、AL、A3、18-8、304、304L、316、316L等。
Shell material: HT , AL , A3 , 18-8 , 304 , 304L , 316 , 316L ,etc..
法兰标准:HG20592-97 PN1.0 (也可根据用户指定的标准生产)。
Flange standard: HG20592-97 PN1.0 (can be produced according to the standard which users appoint).
备注:以下尺寸仅供参考,可根据用户提供的尺寸生产。
The remarks: The following size is only for reference, can be according to the size production that users offer.
H
L
DN 50 80 100 150 200 250 300 350
H 255 260 290 330 350 400 550 650
L 160 213 265 305 355 420 590 690
二、材料:Material :
(阻火)呼吸阀壳体–碳钢、铸铝、不锈钢(根据订单上材质决定)
Hinder the fire and breathe the shell of the valve –WCB、L2、Stainless steel (determine according to the material on the order)
阀盘、阀杆、连接件 -SS304。
Valve one , valve stem , attachment -SS304.
阀口、密封件、滑动套-F4 Port , seal , slipping set -F4
防爆波纹阻火板:不锈钢The anti-blast ripple hinders the fire board: Stainless steel 三、制造和验收标准:SY7511-87 GB5908-86。
Make and confirm the standard: SY7511-87 GB5908-86.
四、(阻火)呼吸阀性能及特点:
Breathe Valve the performance of the valve and characteristic
1、(阻火)呼吸阀的阀体能承受0.2Mpa的水压,无渗透和变形现象。
1, Hinder the valve physical stamina of breathing valve of fire and bear the water pressure of 0. 2Mpa, there is no permeating and phenomenon out of shape.
2、(阻火)呼吸阀耐低温性能在空气相对湿度大于70%,最低温度为-30℃时,经过24小时的冷冻后,其阀盘开启压力符合工作压力要求,(允许压差正负20pa)。
Hinder fire breathe valve able to bear low-temperature performance relative humidity greater than 70% in air , minimum temperature - when the 30 degrees Centigrade, after the refrigeration of 24 hours, its valve of a pressure of openings accord with the working pressure request, (allow to be pressing difference and is being defeated by 20pa).
3、(阻火)呼吸阀的阀盘部件动作时,灵敏度高,动作完成后,保证密封。
3, While hindering a part movement of valve of breathing valve of fire, the sensitivity is high, after movements are finished, guarantee to seal.
4、(阻火)呼吸阀阀内留有足够的空间,保证储罐的通气量。
4, Hinder fire breathe valve valve leave enough space , guarantee to store the keeping in touch with amount of pot.
5≤、(阻火)呼吸阀没达到工作压力以前:公称通径150mm ≤,其泄漏量0.04m3/h ;
≥公称通径220mm ≤,其泄漏量0.4m3/h ;
当(阻火)呼吸阀达到了工作压力以后:阀盘立即开启,保证储罐正常的通气要求。
5, Whether hinder fire breathe valve up to working pressure in the past. Nominal put through foot- path ≤ 150mm, its letting out amount ≤ 0.04m3/h; Nominal open ≤ 220mm directly , its letting out amount ≤ 0.4m3/h; After have hindered the fire and breathed the valve and reached working pressure: Valve record open immediately, is it store tin is it demand to ventilating normal to guarantee.
6、(阻火)呼吸阀的通气量资料表、阻火呼吸阀公称通径计算公式:
6, Whether hinder fire data list of keeping in touch with etc. to breathe valve , hinder fire nominal to calculate formulae directly while being put through to breathe valve.
(1)通气量资料表
公称通径
50 80 100 125 150 200 250 300 350 压力等级
通气量(m 3/h) A
+355 -295 18 16 23 16 45 35 90 75 190 160 340 280 550 450 820 760 1050910 B
+980 -295 21 16 27 16 55 35 100 75 200 160 380 280 600 450 900 760 1130910 C
+1750 -295 26 40 32 20 85 35 140 75 280 160 500 280 800 450 1150760 1150910
五、试压检测Try pressing and measuring
1、检测准备Measure and prepare
将(阻火)呼吸阀正确地安装在试验台上,装置不应有泄漏现象,测试管内壁应平整光滑。
Will hinder the fire and breathe the valve to install on the experimental platform correctly, the device has not let out the phenomenon, the wall should be levelled smoothly in test is in charge of.
2、检测介质Measure the medium
阻火呼吸阀开启压力、通气量、泄漏量的检测介质为空气,其绝对压力为0.1Mpa,温度为20℃,相对湿度为50%,密度为1.2kg/m3,若空气不是此状态时,应换算成此状态的气体。
阻火呼吸阀阀体压力的检测介质为5-35 ℃清水。
Hinder fire breathe
valve open pressure , person who keep in touch with , leak measuring medium of quantity for air, its absolute pressure is 0.1Mpa, temperature is 20 degrees Centigrade, relative humidity is 50%, the density is 1.2kg/m3, if the air should convert into the gas of this state at the time of this state. Hinder fire breathe valve valve body measuring medium of pressure for 5-35 branch water.
3、气压检测The atmospheric pressure measuring
先按四(5)之标准检测其泄漏量,然后按四(3)、四(4)之要求逐台检测其灵敏度及通气量。
Measure person who leak it according to standard of four (5 ) first, then
according to four (3), request of four (4 ) chase platform measure sensitivity and person who keep in touch with their.
4、水压检测Water pressure measuring
阻火呼吸阀进行水压试验的压力为0.2Mpa,保压时间为10min,试压结构应符合四(1)之要求。
Hinder fire breathe valve carry on water pressure pressure of test
0.2Mpa , is it keep time as 10min , is it keep structure should accord with request of 4
(1 ) to try to protect.
5、压力检测The pressure measuring
将(阻火)呼吸阀安装在储气罐接管法兰上,调节阀门,使储气罐内的压力逐步升高或降低,将阀盘调整到使其处于开启状态,由连通的微压计上读出压力值,每分钟读值一次,然后再将阀盘分别转动90°、180°,重复上述试验,每一工况重复三次,取其平均值,试验结果应符合四(2)、四(3)之要求。
Hinder fire breathe valve
installation take over flange in gas tank , regulate the valve, make the pressure in the gas tank rise or reduce progressively , adjust the valve one to making it in state of opening, press on counting reading pressure value a little from feed through , reading
minute worthes once , rotate 90°、 180° respectively valve record, is it test while
being above- mentioned to repeat, every operating mode is repeated three times, fetch its average, the result of the test should accord with the requests of four (2 ) , four (3 ) .
6、泄漏量检测The letting out amount measuring
泄漏量检测的压力为0.75倍的操作压力,该值由微压计上读值。
泄漏量的值由流量计上读值(流量计的精度为0.5-1.0级)每分钟读各测量值一次,共读三次,取其平均值,其结果应符合四(5)之要求。
Person who leak pressure that measure time of
operation pressures, should worth reading value on not is it count to pigeonhole a littling. Leak value of quantity person who read (precision of flow meter for 0.5-1.0 ) read all measurement worth once one minute on flow meter, reading three times altogether, fetch its average, its result should accord with the request for four (5 ) . 7、低温检测The low temperature measuring
(阻火)呼吸阀将阻火呼吸阀安装在试验架上放入低温箱内,低温箱内的温度降到4-15℃,同时和低温箱内连续输入相对温度不低于70%的常温空气,在阀盘末开启前达到呼吸阀内处结箱,再使低温箱内温度降到-30℃,经24小时恒温,将试验架一侧连接到微压计,另一侧通过存有常温空气的稳压罐与空气动力连接。
当呼吸阀的阀盘处于开启状态时,读压力值。
重复三次,均符合四(2)之要求。
Hinder fire breathe valve hinder fire breathe valve install at testing shelf putting low- temperature casing, low-temperature temperature of case drop to 4-15 , input with low-temperature case relative temperature lower than 70% normal atmospheric temperature air in succession at the same time, is it breathe valve place form case , make low-temperature case temperature is dropped to to reach before the end of valve is opened- 30 degrees Centigrade, through 24-hour constant temperature, is it is it is it count to press a little to connect to to test shelf one side, through have normal atmospheric temperature steady voltage pot of air connect another side with air motive force. When valve one which breathes the valve is in state of opening , read pressure value. Repeat three times, accord with the request for four (2 ) .
六、标志包装Sign Packaging
1、每台(阻火)呼吸阀都在明显部位固定永久性产品标牌,标牌应符合GB/T13306之规定,并标明:1, Each hinder fire breathe valves in the obvious regular permanent
product sign of position, the sign should accord with the regulation of GB/T13306 , and indicate:
a、产品名称
b、产品型号
c、操作温度
d、操作压力
e、产品重量
f、出厂编号
g、制造时间
h、使用说明书
2、(阻火)呼吸阀非加工表面应涂防锈底漆,外表再涂两遍面漆。
涂漆应均匀,色泽光亮,法兰面应涂防锈油脂,并用塑料护盖防护。
整体用木箱包装,其包装符合GB/T13384之标准。
2, Hinder fire breathe valve process surface should is it antirust priming paint to scribble , appearance scribble again twice pieces of paint. The lacquer should be even , the color and luster is bright, should apply and antirust the oil the flange, and protect the plastic protecting cover . Packing with wooden case wholly, its packaging accords with the standard of GB/T13384.
3、(阻火)呼吸阀存放在有防雨设施的仓库中,在其存和运输时不准倒置。
3, Hinder fire breathe valve is it have rain-proof among the warehouse of facility , forbid to invert while existing and transporting in it to leave in.
4、每台(阻火)呼吸阀出厂时应附下列文件:
4, Whether each hinder fire breathe valve should enclose the following files while dispatching from the factory.
a、产品说明书
b、产品试压检测报告
c、产品合格证
A , catalogue
b , products try pressing examining report
c , certificate of quality of products
七、呼吸阀的维护与保养
(阻火)呼吸阀的维护与保养每月一次,冬季每月两次。
其方法:先将阀盖轻轻打开,把真空阀盘和压力阀盘取出,检查阀盘与阀盘密封处、阀盘导杆与导杆套有无油污和脏物,如出现油污和脏物应清除干净,然后装回原位,上下拉动几下,检查开启是否灵活可靠。
如果一切正常,再将阀盖盖好紧固。
在维护与保养中,如发现阀盘有划痕、磨损等异常现象,应马上更换或与我公司联系,以使及时得到解决。
Hinder fire maintenance every month one to breathe valve, will it be every month winter two times. Its method : Cover the valve to open gently first , vacuum valve record and pressure valve record take out,check there aren't valve the records, such as appear greasy dirt and dirty thing should remove clean , is it answer the normal position to put , pull several times from head to foot, is it it opens to be flexible and reliable to check. If all going well, and then cover the valve and put on properly fastenning. In maintenance , if find an unusual phenomenon of there is scratch , wearing and tearinging etc. of valve, should change or contact our company at once , so that be solved in time.
湖北武汉谨烨石化设备有限公司HUBEI WUHAN JINYE PETROCHEMICAL EQUIPMENT CO.,LTD
技术开发部
TECHNOLOGICAL DEVELOPMENT。