CTCDRH105RF-102N中文资料

合集下载

CDRH127LDNP-102MC;CDRH127LDNP-101MC;CDRH127LDNP-470MC;中文规格书,Datasheet资料

CDRH127LDNP-102MC;CDRH127LDNP-101MC;CDRH127LDNP-470MC;中文规格书,Datasheet资料

151
□ CDRH127NP-181M
181
□ CDRH127NP-221M
221
□ CDRH127NP-271M
271
□ CDRH127NP-331M
331
□ CDRH127NP-391M
391
□ CDRH127NP-471M
471
□ CDRH127NP-561M
561
□ CDRH127NP-681M

3/4
/
POWER INDUCTORS <SMD Type: CDRH Series>
Type: CDRH127 , CDRH127/LD
□ ※ Description of part name CDRH127/LDNP-1R0N
B Box C Carrier Tape
6.70
21.3m(16.4m)
6.45
26.4m(20.3m)
5.65
28.0m(21.5m)
5.10
36.4m(28.0m)
4.70
41.6m(32.0m)
4.20
53.3m(41.0m)
3.90
60.5m(46.5m)
3.50
78.0m(60.0m)
3.25
90.0m(69.0m)
2.90
120m(92.0m)
330
□ CDRH127NP-390M
390
□ CDRH127NP-470M
470
□ CDRH127NP-560M
560
□ CDRH127NP-680M
680
□ CDRH127NP-820M
820
□ CDRH127NP-101M

ncp18xh103f03rb规格书

ncp18xh103f03rb规格书

ncp18xh103f03rb规格书规格书:NCP18XH103F03RB1. 产品概述:\nNCP18XH103F03RB是一款高性能、高可靠性的电容器。

它采用了先进的材料和制造工艺,具有优异的电气性能和稳定性,适用于广泛的应用领域。

2. 产品特点:\n - 高容量:NCP18XH103F03RB具有较大的电容量,能够满足各种应用需求。

\n - 低ESR:该电容器具有低等效串联电阻(ESR),能够提供更好的功率传输和响应速度。

\n -高温稳定性:NCP18XH103F03RB在高温环境下仍能保持良好的性能,适用于苛刻的工作条件。

\n - 长寿命:该电容器采用了优质材料和可靠的制造工艺,具有长寿命和稳定性。

3. 产品规格:\n - 电容值:10,000pF\n - 额定电压:50V\n - 容差:±1%\n - 工作温度范围:-55℃至+125℃\n - 封装类型:Radial Leaded\n - 封装尺寸(长×宽×高):4.5mm × 3.2mm × 2.5mm\n - 重量:约0.1g4. 应用领域:\n NCP18XH103F03RB广泛应用于电子设备和电路中,包括但不限于:\n - 通信设备\n - 汽车电子\n - 工业自动化\n - 医疗设备\n - 能源管理系统5. 质量认证:\n NCP18XH103F03RB符合国际标准和质量要求,已通过ISO9001质量管理体系认证。

每个产品都经过严格的测试和质量控制,确保其性能和可靠性。

6. 包装与交货:\n NCP18XH103F03RB以卷装形式供应,每卷包含1000个电容器。

产品将在订单确认后的3个工作日内交付。

以上是对NCP18XH103F03RB规格书的简要介绍。

如需更详细的信息,请参考产品说明书或与我们联系。

我们将竭诚为您提供技术支持和解答您的疑问。

TH2515 仪器说明书

TH2515 仪器说明书

Ver 2.1目录Ver 2.0 (2)第1章仪器简介与开箱安装 (8)1.1仪器简介 (8)1.2开箱检查 (8)1.3电源连接 (8)1.4保险丝 (8)1.5环境 (8)1.6使用测试夹具 (9)1.7预热 (9)1.8仪器的其它特性 (9)第2章前面板说明及入门操作 (10)2.1前面板说明 (10)2.2后面板说明 (11)2.3显示区域的定义 (12)2.4按键及其相应的显示页面 (13)2.4.1测量主菜单按键【DISP】 (13)2.4.2系统设置主菜单按键【SETUP】 (13)2.5基本操作 (13)2.6开机 (14)第3章基本操作 (15)3.1<测量显示>页面 (15)3.1.1测试功能 (15)3.1.2测试量程 (16)3.1.3测试速度 (17)3.1.4文件管理 (17)3.1.5其他工具 (17)3.2<比较显示>页面 (18)3.2.1文件管理 (19)3.2.2工具 (19)3.2.3比较 (19)3.2.4比较模式和上下限、百分比误差设置 (19)3.3<档显示>页面 (19)3.4<统计显示>页面 (21)3.4.1边界模式和其相应值的设定 (21)3.4.2统计状态 (21)3.4.3统计分析参数说明 (21)3.4.4工具 (22)3.4.5文件 (22)3.5<测量设置>页面 (22)3.6<TC/Δt设置>页面 (24)3.6.1温度校正(Temperature Correction 简称TC) (25)3.6.2温度转换(temperature conversion 简称t ) (25)3.6.3温度传感器的类型 (26)3.6.4参数设定 (27)3.6.5文件 (27)3.7<档设置>页面 (27)3.7.1文件 (29)3.7.2工具 (29)第4章系统设置和文件管理 (30)4.1系统设置 (30)4.1.1触摸音 (30)4.1.2语言 (30)4.1.3口令 (31)4.1.4总线模式 (31)4.1.5波特率 (32)4.1.6总线地址 (32)4.1.7EOC信号 (32)4.1.8Err.OUT信号 (33)4.1.9电源频率 (34)4.1.10时间和日期设定 (34)4.2<文件管理>功能页面 (34)4.2.1存储/调用功能简介 (34)4.2.2U盘上的文件夹/文件结构 (35)4.2.3DHCP (39)4.2.4IP地址 (40)4.2.5子网掩码 (40)4.2.6网关 (40)4.2.7首选DNS、备用DNS (40)第5章性能指标 (41)5.1测量功能 (41)5.1.1测量参数及符号 (41)5.1.2测量组合 (41)5.1.3等效方式 (41)5.1.4量程 (41)5.1.5触发 (41)5.1.6测试端方式 (41)5.1.7测量中的各种时间的开销 (41)5.1.8平均 (42)5.1.9显示的位数 (42)5.2测试信号 (42)5.2.1量程电流 (42)5.2.2开路输出电压 (42)5.2.3测量显示最大范围 (42)5.3测量准确度 (43)5.3.2温度测量的准确度(Pt500) (44)5.3.3温度测量的准确度(模拟输入) (45)5.3.4温度修正系数K (45)第6章远程控制 (46)6.1RS232C接口说明 (46)6.2GPIB接口说明(选购件) (47)6.2.1GPIB接口功能 (49)6.2.2GPIB 地址 (49)6.2.3GPIB总线功能 (49)6.2.4可编程仪器命令标准(SCPI) (50)6.3LAN远程控制系统 (50)6.3.1通过浏览器访问TH2515 (52)6.3.2通过上位机软件访问TH2515 (52)6.4USBTMC远程控制系统 (53)6.4.1系统配置 (53)6.4.2安装驱动 (53)6.5USBVCOM虚拟串口 (54)6.5.1系统配置 (54)6.5.2安装驱动 (54)第7章RS232命令参考 (55)7.1SCPI系统命令 (55)7.1.1DISPlay子系统命令集 (55)7.1.2FUNCtion 子系统命令集 (56)7.1.3APERture子系统命令集 (61)7.1.4TRIGer子系统命令集 (61)7.1.5FETCh?子系统命令集 (63)7.1.6TEMPerature子系统命令集 (64)7.1.7COMParator子系统命令集 (66)7.1.8BIN子系统命令集 (69)7.1.9STA Tistics子系统命令集 (73)7.1.10IO子系统命令集 (76)7.1.11MEMory子系统命令集 (77)7.1.12SYSTem 子系统命令集 (78)7.1.13SCPI公用命令 (81)7.2MODBUS系统命令 (83)7.2.1MODBUS协议说明 (84)7.2.2公用指令操作说明 (85)7.2.3DISP指令操作说明 (86)7.2.4FUNC指令操作说明 (86)7.2.5APER指令操作说明 (87)7.2.6TRIG指令操作说明 (87)7.2.7FETC指令操作说明 (88)7.2.8TEMP指令操作说明 (88)7.2.10BIN指令操作说明 (90)7.2.11STA T指令操作说明 (93)7.2.12IO指令操作说明 (94)7.2.13SYST指令操作说明 (94)第8章Handler接口使用说明及程序升级方法 (99)第9章包装及保修 (103)9.1标志 (103)9.2包装 (103)9.3运输 (103)9.4贮存 (103)9.5保修 (103)本说明书所描述的可能并非仪器所有内容,同惠公司有权对本产品的性能、功能、内部结构、外观、附件、包装物等进行改进和提高而不作另行说明!由此引起的说明书与仪器不一致的困惑,可通过封面的地址与我公司进行联系。

NRG ELX1225 2022年7月技术数据:EPoxy封封闭径向NTC热感应器商品介绍说明书

NRG ELX1225 2022年7月技术数据:EPoxy封封闭径向NTC热感应器商品介绍说明书

NRGEpoxy sealed radial lead NTC thermistorProduct features• Epoxy sealed radial NTC thermistor • Temperature sensing, quick response time • Bead with ring lug• Wide resistance range:1 k Ω to 470 kΩ•Non-linear change in resistance vs temperaturePb HALOGENHF FREEPackaging information• Bulk, Type 3: 250 parts per poly bag •Bulk, Others: 500 parts per poly bagT able 1. Part numberingNRG a xxy b xxxx Bx c xFamily nameNRGRing lug type1/2/3/ (See mechanicalparameters for details)Resistancexxy= x.x * 10y Ωex: 103 = 1.0 * 103 = 1000 ΩResistance tolerance codeF = ±1%, H = ±3%Beta tolerance codeF = ±1%,G = ±2%,H = ±3%Beta type codeB1 = 25/50, B2 = 25/85Beta value ex: 3465, 4215, etcLead styleDifferent lead dimensionsApplications• Industrial Process Control • Commercial appliances•Battery, supercapacitor and energy storage systems• Uninterruptible power supplies • Consumer appliances •Medical devices•Heating, ventilation and air conditioning, Refrigeration (HVACR)• Food service equipment • IoT• White goods/household appliances •Computer and peripheral productsEnvironmental compliance and general specificationsSee electrical specification table for option details2Technical Data ELX1225Effective July 2022NRGEpoxy sealed radial lead NTC thermistor/electronicsMechanical parameters- mmLug type 1Lug type 2Lug type 3• 26AWG black Insulated lead wire with terminals tinned3Technical Data ELX1225Effective July 2022NRGEpoxy sealed radial lead NTC thermistor /electronics Electrical specificationsPart numberZero power resistance @ 25°C R 25 (kΩ)Ring lug type(Part number code)R 25Tolerance (Part number code)Beta type (Part number code)Beta value (K)Betatolerance (Part number code)Maximum power@ +25°C P max (mW)Dissipationfactor (mW/°C)Thermaltime constant T (second)Operation temperature TL~TU(°C)NRGa103bxxxxBxc 1(1), (2), (3)±1% (F) ,±3% (H)25/85 (B2)3435±2% (G), ±3% (H)50≥ 2.5 (type3) ≥ 3.0 (others)≤ 10 (type3) ≤ 9 (others)-30 to +105NRGa683bxxxxBxc 6.8(1), (2), (3)±1% (F) ,±3% (H)25/85 (B2)3470±2% (G), ±3% (H)50≥ 2.5 (type3) ≥ 3.0 (others)≤ 10 (type3) ≤ 9 (others)-30 to +105NRGa683bxxxxBxc 6.8(1), (2), (3)±1% (F) ,±3% (H)25/85 (B2)3975±2% (G), ±3% (H)50≥ 2.5 (type3) ≥ 3.0 (others)≤ 10 (type3) ≤ 9 (others)-30 to +105NRGa104bxxxxBxc 10(1), (2), (3)±1% (F) ,±3% (H)25/85 (B2)3435±1% (F), ±3% (H)50≥ 2.5 (type3) ≥ 3.0 (others)≤ 10 (type3) ≤ 9 (others)-30 to +105NRGa104bxxxxBxc 10(1), (2), (3)±1% (F) ,±3% (H)25/85 (B2)3975±1% (F), ±3% (H)50≥ 2.5 (type3) ≥ 3.0 (others)≤ 10 (type3) ≤ 9 (others)-30 to +105NRGa203bxxxxBxc 2(1), (2), (3)±1% (F) ,±3% (H)25/85 (B2)3435±1% (F), ±3% (H)50≥ 2.5 (type3) ≥ 3.0 (others)≤ 10 (type3) ≤ 9 (others)-30 to +105NRGa224bxxxxBxc 22(1), (2), (3)±1% (F) ,±3% (H)25/85 (B2)3740±1% (F), ±3% (H)50≥ 2.5 (type3) ≥ 3.0 (others)≤ 10 (type3) ≤ 9 (others)-30 to +105NRGa334bxxxxBxc 33(1), (2), (3)±1% (F) ,±3% (H)25/85 (B2)3975±1% (F), ±3% (H)50≥ 2.5 (type3) ≥ 3.0 (others)≤ 10 (type3) ≤ 9 (others)-30 to +105NRGa474bxxxxBxc 47(1), (2), (3)±1% (F) ,±3% (H)25/85 (B2)4090±1% (F), ±3% (H)50≥ 2.5 (type3) ≥ 3.0 (others)≤ 10 (type3) ≤ 9 (others)-30 to +105NRGa504bxxxxBxc 50(1), (2), (3)±1% (F) ,±3% (H)25/85 (B2)3950±1% (F), ±3% (H)50≥ 2.5 (type3) ≥ 3.0 (others)≤ 10 (type3) ≤ 9 (others)-30 to +105NRGa504bxxxxBxc 50(1), (2), (3)±1% (F) ,±3% (H)25/85 (B2)4050±1% (F), ±3% (H)50≥ 2.5 (type3) ≥ 3.0 (others)≤ 10 (type3) ≤ 9 (others)-30 to +105NRGa105bxxxxBxc 100(1), (2), (3)±1% (F) ,±3% (H)25/85 (B2)4000±1% (F), ±3% (H)50≥ 2.5 (type3) ≥ 3.0 (others)≤ 10 (type3) ≤ 9 (others)-30 to +105NRGa105bxxxxBxc 100(1), (2), (3)±1% (F) ,±3% (H)25/85 (B2)4190±2% (G), ±3% (H)50≥ 2.5 (type3) ≥ 3.0 (others)≤ 10 (type3) ≤ 9 (others)-30 to +105NRGa105bxxxxBxc 100(1), (2), (3)±1% (F) ,±3% (H)25/85 (B2)4360±2% (G), ±3% (H)50≥ 2.5 (type3) ≥ 3.0 (others)≤ 10 (type3) ≤ 9 (others)-30 to +105NRGa475bxxxxBxc 470(1), (2), (3)±1% (F) ,±3% (H)25/85 (B2)4570±2% (G), ±3% (H)50≥ 2.5 (type3) ≥ 3.0 (others)≤ 10 (type3) ≤ 9 (others)-30 to +105NRGa203bxxxxBxc 2(1), (2), (3)±1% (F) ,±3% (H)25/50 (B1)3380±2% (G), ±3% (H)50≥ 2.5 (type3) ≥ 3.0 (others)≤ 10 (type3) ≤ 9 (others)-30 to +105NRGa503bxxxxBxc 5(1), (2), (3)±1% (F) ,±3% (H)25/50 (B1)3420±2% (G), ±3% (H)50≥ 2.5 (type3) ≥ 3.0 (others)≤ 10 (type3) ≤ 9 (others)-30 to +105NRGa503bxxxxBxc 5(1), (2), (3)±1% (F) ,±3% (H)25/50 (B1)3900±2% (G), ±3% (H)50≥ 2.5 (type3) ≥ 3.0 (others)≤ 10 (type3) ≤ 9 (others)-30 to +105NRGa104bxxxxBxc 10(1), (2), (3)±1% (F) ,±3% (H)25/50 (B1)3380±1% (F), ±3% (H)50≥ 2.5 (type3) ≥ 3.0 (others)≤ 10 (type3) ≤ 9 (others)-30 to +105NRGa104bxxxxBxc 10(1), (2), (3)±1% (F) ,±3% (H)25/50 (B1)4000±1% (F), ±3% (H)50≥ 2.5 (type3) ≥ 3.0 (others)≤ 10 (type3) ≤ 9 (others)-30 to +105NRGa104bxxxxBxc 10(1), (2), (3)±1% (F) ,±3% (H)25/50 (B1)3950±1% (F), ±3% (H)50≥ 2.5 (type3) ≥ 3.0 (others)≤ 10 (type3) ≤ 9 (others)-30 to +105NRGa684bxxxxBxc 68(1), (2), (3)±1% (F) ,±3% (H)25/50 (B1)3950±1% (F), ±3% (H)50≥ 2.5 (type3) ≥ 3.0 (others)≤ 10 (type3) ≤ 9 (others)-30 to +105NRGa224bxxxxBxc 22(1), (2), (3)±1% (F) ,±3% (H)25/50 (B1)3700±1% (F), ±3% (H)50≥ 2.5 (type3) ≥ 3.0 (others)≤ 10 (type3) ≤ 9 (others)-30 to +105NRGa474bxxxxBxc 47(1), (2), (3)±1% (F) ,±3% (H)25/50 (B1)3950±1% (F), ±3% (H)50≥ 2.5 (type3) ≥ 3.0 (others)≤ 10 (type3) ≤ 9 (others)-30 to +105NRGa474bxxxxBxc 47(1), (2), (3)±1% (F) ,±3% (H)25/50 (B1)4020±1% (F), ±3% (H)50≥ 2.5 (type3) ≥ 3.0 (others)≤ 10 (type3) ≤ 9 (others)-30 to +105NRGa105bxxxxBxc 100(1), (2), (3)±1% (F) ,±3% (H)25/50 (B1)3950±1% (F), ±3% (H)50≥ 2.5 (type3) ≥ 3.0 (others)≤ 10 (type3) ≤ 9 (others)-30 to +105NRGa105bxxxxBxc 100(1), (2), (3)±1% (F) ,±3% (H)25/50 (B1)4120±2% (G), ±3% (H)50≥ 2.5 (type3) ≥ 3.0 (others)≤ 10 (type3) ≤ 9 (others)-30 to +105NRGa225bxxxxBxc220(1), (2), (3)±1% (F) ,±3% (H)25/50 (B1)4370±2% (G), ±3% (H)50≥ 2.5 (type3) ≥ 3.0 (others)≤ 10 (type3) ≤ 9 (others)-30 to +105a= Enter ring lug type from table above (1, 2, 3) See Mechanical parameters for lug type details b= Enter resistance tolerance code from table above (F = ±1%, H = ±3%)Bx= Enter Beta type code from table above (B1 = 25/50, B2 = 25/85)c= Enter Beta tolerance code from table above (F = ±1%, G = ±2%, H = ±3%)4Technical Data ELX1225Effective July 2022NRGEpoxy sealed radial lead NTC thermistor/electronicsPart number NRG1033435NRG2033435NRG1043435NRG1043975NRG2243740NRG3343975B typeB25/85B25/85B25/85B25/85B25/85B25/85Temperature (°C)Resistance (kΩ)Resistance (kΩ)Resistance (kΩ)Resistance (kΩ)Resistance (kΩ)Resistance(kΩ)-4020.089532539.55751116.42-3919.1491.71304.8337.47541.351045.23-3818.2488.53286.0135.55509.86978.99-3717.3885.46268.4533.74480.37917.34-3616.5682.51252.0632.03452.75859.93-3515.7879.66236.7630.41426.86806.46-3415.0476.9222.4728.88402.6756.62-3314.3374.25209.1127.43379.85710.15-3213.6671.69196.6326.05358.5666.81-3113.0169.22184.9524.76338.48626.37-3012.466.84174.0323.53319.68588.62-2911.8264.54163.8222.36302.02553.36-2811.2662.32154.2521.26285.44520.42-2710.7360.18145.320.22269.86489.64-2610.2358.11136.9119.23255.21460.85-259.7556.12129.0518.3241.44433.93-249.2954.19121.6817.41228.49408.73-238.8552.34114.7816.57216.3385.14-228.4450.54108.315.77204.83363.06-218.0448.81102.2215.02194.03342.36-207.6747.1496.5114.3183.86322.97-197.3145.5391.1513.62174.28304.79-18 6.9643.9786.1212.98165.24287.74-17 6.6442.4781.412.37156.73271.74-16 6.3341.0276.9511.79148.7256.72-15 6.0339.6272.7811.24141.13242.62-14 5.7538.2768.8510.72133.98229.37-13 5.4936.9665.1610.22127.23216.93-12 5.2335.761.689.75120.86205.23-11 4.9934.4958.419.31114.85194.23-10 4.7633.3155.338.88109.16183.88-9 4.5432.1852.428.48103.79174.15-8 4.3331.0849.698.198.71164.98-7 4.1330.0347.117.7393.91156.35-6 3.942944.687.3989.37148.22-5 3.7628.0242.397.0685.07140.56-4 3.5927.0740.23 6.7481133.34-3 3.4226.1538.19 6.4577.15126.54-2 3.2725.2636.27 6.1673.5120.12-1 3.1224.434.45 5.8970.05114.060 2.9823.5732.73 5.6466.78108.341 2.8522.7731.11 5.3963.67102.942 2.722229.58 5.1660.7397.843 2.621.2628.13 4.9457.9493.024 2.4820.5426.76 4.7355.2988.475 2.3719.8425.46 4.5352.7884.176 2.2719.1724.23 4.3450.480.17 2.1718.5223.07 4.1648.1476.258 2.0717.8921.97 3.9845.9972.69 1.9817.2920.93 3.8243.9469.1510 1.8916.7119.95 3.664265.8911 1.8116.1419.01 3.5140.1662.812 1.7315.618.13 3.3738.4159.8713 1.6615.0717.29 3.2336.7457.0914 1.5914.5616.49 3.135.1654.4615 1.5214.0715.74 2.9833.6551.9616 1.4613.615.02 2.8632.2149.5917 1.413.1414.34 2.7430.8547.35181.3412.713.7 2.6429.5445.21T emperature characteristics5Technical Data ELX1225Effective July 2022NRGEpoxy sealed radial lead NTC thermistor /electronics T emperature characteristics, cont.Part number NRG1033435NRG2033435NRG1043435NRG1043975NRG2243740NRG3343975B typeB25/85B25/85B25/85B25/85B25/85B25/85Temperature (°C)Resistance (kΩ)Resistance (kΩ)Resistance (kΩ)Resistance (kΩ)Resistance (kΩ)Resistance(kΩ)191.2812.2713.09 2.5328.343.1920 1.2311.8612.5 2.4327.1241.2721 1.1811.4611.95 2.342639.4422 1.1311.0811.43 2.2524.9337.7123 1.0910.710.93 2.1623.936.0624 1.0410.3510.45 2.0822.9334.49251101022233260.96039.679.57 1.9221.1131.58270.92249.349.16 1.8520.2730.23280.88629.038.77 1.7819.4628.95290.85178.738.4 1.7218.6927.73300.81888.448.05 1.6517.9526.56310.78738.167.71 1.5917.2525.45320.75737.897.39 1.5416.5724.4330.72877.627.09 1.4815.9323.39340.70137.37 6.8 1.4315.3222.43350.67527.13 6.52 1.3814.7321.52360.6502 6.89 6.25 1.3314.1720.64370.6263 6.666 1.2813.6319.81380.6035 6.44 5.76 1.2313.1219.02390.5817 6.23 5.53 1.1912.6318.26400.5608 6.03 5.31 1.1512.1517.54410.5409 5.83 5.1 1.1111.716.84420.5218 5.64 4.9 1.0711.2716.18430.5036 5.45 4.71 1.0410.8615.55440.4861 5.27 4.53110.4614.95450.4693 5.1 4.350.966810.0814.37460.4533 4.94 4.190.93459.7213.82470.438 4.78 4.030.90349.3713.3480.4233 4.62 3.870.87369.0412.79490.4092 4.47 3.730.84498.7212.31500.3957 4.33 3.590.81738.4111.85510.3827 4.19 3.450.79088.1111.41520.3703 4.05 3.330.76537.8310.99530.3584 3.92 3.20.74087.5610.58540.347 3.8 3.090.71737.310.19550.336 3.67 2.970.69467.059.82560.3255 3.56 2.870.6728 6.819.47570.3154 3.44 2.760.6518 6.589.13580.3057 3.34 2.660.6315 6.358.8590.2963 3.23 2.570.6121 6.148.49600.2874 3.13 2.480.5933 5.948.19610.2788 3.03 2.390.5753 5.747.9620.2705 2.93 2.310.5579 5.557.62630.2625 2.84 2.230.5411 5.377.36640.2549 2.75 2.150.525 5.197.1650.2475 2.67 2.080.5094 5.02 6.86660.2404 2.5920.4944 4.86 6.62670.2336 2.51 1.940.4799 4.7 6.4680.227 2.43 1.870.4659 4.55 6.18690.2207 2.35 1.810.4525 4.41 5.97700.2146 2.28 1.750.4395 4.27 5.77710.2087 2.21 1.690.4269 4.13 5.58720.203 2.14 1.630.4148 4.01 5.39730.1976 2.08 1.580.4031 3.88 5.21740.1923 2.02 1.530.3919 3.76 5.04750.1872 1.96 1.480.381 3.64 4.88760.1823 1.9 1.430.3704 3.53 4.72770.1776 1.84 1.380.3603 3.43 4.576Technical Data ELX1225Effective July 2022NRGEpoxy sealed radial lead NTC thermistor/electronicsT emperature characteristics, cont.Part number NRG1033435NRG2033435NRG1043435NRG1043975NRG2243740NRG3343975B typeB25/85B25/85B25/85B25/85B25/85B25/85Temperature (°C)Resistance (kΩ)Resistance (kΩ)Resistance (kΩ)Resistance (kΩ)Resistance (kΩ)Resistance(kΩ)780.173 1.79 1.340.3504 3.32 4.42790.1686 1.73 1.30.3409 3.22 4.28800.1643 1.68 1.260.3318 3.12 4.14810.1602 1.63 1.220.3229 3.03 4.01820.1562 1.59 1.180.3143 2.94 3.89830.1524 1.54 1.140.306 2.85 3.77840.1487 1.49 1.110.298 2.77 3.65850.1451 1.45 1.070.2902 2.69 3.54860.1416 1.41 1.040.2827 2.61 3.43870.1383 1.37 1.010.2754 2.54 3.32880.135 1.330.97640.2684 2.46 3.22890.1319 1.290.9470.2615 2.39 3.12900.1288 1.260.91850.2549 2.32 3.03910.1259 1.220.89110.2486 2.26 2.94920.123 1.190.86470.2424 2.2 2.85930.1202 1.150.83910.2364 2.13 2.77940.1176 1.120.81450.2305 2.07 2.68950.115 1.090.79070.2249 2.02 2.61960.1124 1.060.76780.2194 1.96 2.53970.11 1.030.74560.2141 1.91 2.46980.107610.72420.209 1.86 2.39990.10530.97750.70350.204 1.81 2.321000.10310.95130.68350.1992 1.76 2.251010.10090.9260.66410.1945 1.71 2.191020.09880.90140.64550.19 1.66 2.121030.09680.87770.62740.1856 1.62 2.071040.09480.85470.610.1813 1.58 2.011050.09290.83240.59310.1771 1.54 1.957Technical Data ELX1225Effective July 2022NRGEpoxy sealed radial lead NTC thermistor /electronics T emperature characteristicsPart number NRG1054000NRG1054190NRG1054360NRG2033380NRG1043380NRG1044000B type B25/85B25/85B25/85B25/50B25/50B25/50Temperature (°C)Resistance (kΩ)Resistance (kΩ)Resistance (kΩ)Resistance (kΩ)Resistance (kΩ)Resistance (kΩ)-4031003300360039.8195325-392910.563098.573377.1937.69184.63305.06-382733.692910.373169.1435.71174.87286.45-372568.52734.472974.7933.84165.67269.05-362414.172570.022793.1932.07157.01252.8-352269.932416.232623.4730.41148.84237.61-342135.072272.352464.7828.84141.14223.4-332008.932137.72316.3727.36133.89210.11-321890.92011.652177.5425.96127.04197.67-311780.431893.632047.6324.64120.58186.03-3016771783.071926.0223.39114.48175.13-291580.121679.481812.1622.21108.73164.93-281489.351582.391705.5121.1103.29155.36-271404.261491.361605.6120.0598.15146.4-261324.491405.991511.9819.0593.3138-251249.661325.91424.2218.1188.71130.12-241179.461250.741341.9317.2284.38122.73-231113.571180.21264.7416.3880.28115.8-221051.71113.951192.3315.5876.39109.29-21993.61051.741124.3814.8372.72103.18-20939.01993.291060.5914.1169.2597.44-19887.7938.351000.713.4465.9692.04-18839.47886.71944.4412.862.8486.98-17794.11838.15891.612.1959.8882.21-16751.44792.48841.9311.6257.0977.74-15711.28749.5795.2511.0754.4373.52-14673.48709.06751.3610.5651.9269.56-13637.88670.98710.0810.0749.5365.83-12604.36635.13671.259.647.2762.32-11572.77601.36634.79.1645.1259.01-10542.99569.54600.318.7443.0855.9-9514.92539.56567.938.3541.1552.96-8488.45511.29537.447.9739.3150.2-7463.47484.63508.717.6137.5647.59-6439.9459.49481.657.2735.945.13-5417.65435.77456.14 6.9534.3342.81-4396.65413.38432.1 6.6432.8340.62-3376.81392.25409.42 6.3531.438.56-2358.06372.29388.04 6.0730.0536.61-1340.35353.45367.87 5.8128.7634.770323.6335.65348.83 5.5627.5333.031307.76318.82330.86 5.3226.3631.382292.78302.92313.9 5.0925.2529.833278.61287.88297.88 4.8824.1928.364265.2273.67282.74 4.6723.1826.975252.5260.22268.45 4.4822.2225.666240.48247.49254.93 4.2921.324.427229.09235.44242.16 4.1120.4323.248218.3224.04230.09 3.9419.5922.139208.07213.25218.66 3.7818.821.0710198.37203.02207.86 3.6318.0420.0711189.18193.33197.64 3.4817.3219.1312180.46184.15187.96 3.3416.6318.2313172.19175.45178.81 3.2115.9717.3814164.33167.2170.13 3.0815.3416.5715156.88159.38161.92 2.9614.7315.8116149.81151.96154.14 2.8414.1615.0817143.08144.92146.77 2.7313.6114.418136.7138.24139.78 2.6213.0913.748Technical Data ELX1225Effective July 2022NRGEpoxy sealed radial lead NTC thermistor/electronicsT emperature characteristics, cont.Part number NRG1054000NRG1054190NRG1054360NRG2033380NRG1043380NRG1044000B type B25/85B25/85B25/85B25/50B25/50B25/50Temperature (°C)Resistance (kΩ)Resistance (kΩ)Resistance (kΩ)Resistance (kΩ)Resistance (kΩ)Resistance (kΩ)19130.63131.9133.16 2.5212.5813.1220124.87125.87126.88 2.4212.112.5321119.38120.16120.93 2.3311.6511.9722114.17114.73115.28 2.2411.2111.4423109.21109.57109.92 2.1610.7910.9424104.49104.66104.83 2.0810.3810.4625100100100210102695.7395.5795.41 1.939.639.572791.6691.3591.06 1.859.289.152887.7887.3486.92 1.798.948.762984.0983.5382.99 1.728.628.393080.5779.979.26 1.668.318.033177.2176.4575.71 1.68.017.693274.0273.1672.34 1.547.727.373370.9770.0269.13 1.497.457.063468.0667.0466.07 1.447.19 6.773565.2964.263.17 1.39 6.94 6.493662.6461.4960.41 1.34 6.69 6.223760.1258.9157.78 1.29 6.46 5.973857.7156.4555.27 1.25 6.24 5.723955.4154.152.89 1.2 6.03 5.494053.2151.8650.62 1.16 5.82 5.274151.1149.7348.46 1.12 5.62 5.064249.147.6946.4 1.09 5.43 4.864347.1845.7544.43 1.05 5.25 4.674445.3543.8942.56 1.01 5.08 4.484543.642.1240.780.9809 4.91 4.314641.9240.4339.080.9487 4.75 4.144740.3238.8137.450.9178 4.59 3.984838.7837.2735.910.8881 4.44 3.834937.3235.7934.430.8595 4.3 3.685035.9134.3833.020.832 4.16 3.545134.5733.0431.680.8056 4.03 3.415233.2831.7530.390.7801 3.9 3.285332.0530.5229.160.7556 3.78 3.165430.8629.3427.990.7321 3.66 3.045529.7328.2126.870.7094 3.54 2.935628.6527.1325.810.6875 3.43 2.825727.6126.124.780.6665 3.33 2.725826.6125.1123.810.6462 3.22 2.625925.6524.1722.870.6266 3.12 2.526024.7423.2621.980.6078 3.03 2.436123.8622.3921.130.5896 2.94 2.356223.0121.5620.310.5721 2.85 2.266322.220.7619.530.5553 2.76 2.186421.432018.780.539 2.68 2.116520.6819.2718.060.5233 2.6 2.036619.9618.5717.380.5081 2.52 1.966719.2817.916.720.4935 2.45 1.896818.6117.2516.10.4794 2.38 1.836917.9816.6315.490.4658 2.31 1.777017.3716.0414.920.4526 2.24 1.717116.7815.4714.360.4399 2.18 1.657216.2214.9213.840.4277 2.12 1.597315.6814.413.330.4158 2.06 1.547415.1613.8912.840.40442 1.497514.6513.4112.370.3933 1.94 1.447614.1712.9411.930.3826 1.89 1.397713.7112.511.50.3722 1.84 1.359Technical Data ELX1225Effective July 2022NRGEpoxy sealed radial lead NTC thermistor /electronics T emperature characteristics, cont.Part number NRG1054000NRG1054190NRG1054360NRG2033380NRG1043380NRG1044000B type B25/85B25/85B25/85B25/50B25/50B25/50Temperature (°C)Resistance (kΩ)Resistance (kΩ)Resistance (kΩ)Resistance (kΩ)Resistance (kΩ)Resistance (kΩ)7813.2612.0711.090.3622 1.79 1.37912.8311.6610.690.3526 1.74 1.268012.4211.2610.310.3432 1.69 1.228112.0210.889.950.3342 1.64 1.188211.6310.519.60.3254 1.6 1.148311.2610.169.260.3169 1.56 1.118410.919.828.940.3087 1.51 1.078510.579.58.630.3008 1.47 1.048610.239.188.330.2931 1.44 1.01879.928.888.050.2856 1.40.9746889.618.597.770.2784 1.360.9445899.318.317.510.2714 1.330.9156909.038.047.250.2646 1.290.8877918.757.787.010.2581 1.260.8608928.487.53 6.780.2517 1.230.8349938.237.29 6.550.2455 1.190.8098947.987.06 6.330.2396 1.160.7857957.74 6.84 6.120.2338 1.140.7624967.51 6.62 5.920.2281 1.110.7399977.29 6.42 5.730.2227 1.080.7182987.07 6.22 5.540.2174 1.050.697299 6.87 6.02 5.360.2123 1.030.677100 6.67 5.84 5.190.207310.6575101 6.47 5.66 5.020.20240.9770.6386102 6.29 5.48 4.860.19770.95330.6204103 6.1 5.32 4.710.19320.93030.6027104 5.93 5.16 4.560.18870.90790.5857105 5.765 4.420.18440.88630.569310Technical Data ELX1225Effective July 2022NRGEpoxy sealed radial lead NTC thermistor/electronicsT emperature characteristicsPart number NRG1043950NRG2243700NRG1053950NRG1054120NRG2254370B typeB25/50B25/50B25/50B25/50B25/50Temperature (°C)Resistance (kΩ)Resistance (kΩ)Resistance (kΩ)Resistance (kΩ)Resistance(kΩ)-403252056.32300032508728.94-39304.831932.462819.843053.328171.87-38286.011816.682651.42869.427652.85-37268.461708.422493.872697.437169.11-36252.071607.152346.482536.526718.12-35236.771512.42208.542385.946297.51-34222.481423.72079.412244.975905.11-33209.121340.651958.462112.965538.92-32196.641262.861845.161989.315197.08-31184.961189.971738.981873.454877.85-30174.041121.661639.441764.864579.66-29163.831057.611546.091663.054301.03-28154.26997.531458.531567.574040.59-27145.31941.171376.3614783797.08-26136.92888.281299.231393.953569.34-25129.06838.621226.811315.063356.26-24121.69791.991158.781240.993156.86-23114.78748.181094.871171.432970.19-22108.3707.021034.81106.072795.39-21102.22668.32978.321044.662631.66-2096.52631.94925.21986.932478.25-1991.16597.72875.25932.662334.46-1886.13565.53828.23881.612199.66-1781.4535.23783.97833.582073.24-1676.96506.7742.3788.391954.64-1572.78479.84703.05745.851843.36-1468.86454.53666.07705.81738.91-1365.16430.69631.22668.081640.85-1261.69408.22598.37632.551548.75-1158.41387.03567.39599.061462.23-1055.33367.05538.17567.51380.93-952.43348.19510.59537.751304.51-849.69330.41484.57509.691232.66-747.12313.62460483.221165.09-644.69297.76436.81458.241101.53-542.4282.79414.89434.671041.71-440.23268.64394.19412.42985.41-338.19255.28374.62391.4932.4-236.27242.64356.11371.56882.49-134.45230.7338.62352.81835.46032.73219.4322.07335.09791.15131.11208.71306.41318.34749.39229.58198.59291.59302.5710.02328.13189.02277.56287.53672.9426.76179.96264.28273.36637.88525.46171.37251.69259.96604.84624.23163.24239.77247.27573.66723.07155.53228.48235.26544.22821.98148.23217.77223.89516.43920.93141.31207.61213.12490.181019.95134.74197.98202.92465.381119.02128.51188.84193.25441.951218.13122.6180.18184.08419.811317.29117171.95175.4398.871416.5111.67164.13167.16379.071515.74106.62156.72159.35360.341615.02101.82149.67151.94342.621714.3497.26142.97144.9325.851813.792.93136.61138.23309.9811Technical Data ELX1225Effective July 2022NRG Epoxy sealed radial lead NTC thermistor /electronics T emperature characteristics, cont.Part number NRG104 3950NRG2243700NRG1053950NRG1054120NRG2254370B type B25/50B25/50B25/50B25/50B25/50Temperature (°C)Resistance (kΩ)Resistance (kΩ)Resistance (kΩ)Resistance (kΩ)Resistance (kΩ)1913.0988.81130.56131.89294.952012.584.89124.81125.87280.722111.9581.17119.35120.16267.242211.4377.63114.14114.73254.462310.9374.26109.19109.57242.362410.4571.05104.48104.66230.88251068100100220269.5765.0995.7395.57209.68279.1662.3391.6691.35199.89288.7759.6987.7987.34190.6298.457.1884.183.52181.79308.0554.7980.5879.89173.42317.7152.5177.2376.44165.48327.3950.3374.0373.14157.93337.0948.2670.9870.01150.7734 6.846.2868.0867.02143.9635 6.5244.465.364.18137.4936 6.2542.662.6561.47131.3437640.8860.1358.88125.4938 5.7639.2457.7156.42119.9339 5.5337.6755.4154.07114.6440 5.3136.1753.2151.83109.6141 5.134.7451.149.69104.8242 4.933.3849.0947.65100.2643 4.7132.0747.1745.7195.9244 4.5330.8245.3443.8591.7945 4.3529.6343.5842.0887.8546 4.1928.4941.940.3884.147 4.0327.440.338.7780.5348 3.8726.3538.7637.2277.1349 3.7325.3637.2935.7473.8850 3.5924.435.8834.3370.7951 3.4523.4834.5332.9867.8452 3.3322.6133.2431.6965.0353 3.221.7732.0130.4662.3454 3.0920.9630.8229.2859.7855 2.9720.1929.6928.1557.3356 2.8719.4528.627.075557 2.7618.7527.5626.0452.7758 2.6618.0726.5625.0550.6559 2.5717.4225.624.148.6160 2.4816.7924.6823.246.6761 2.3916.1923.822.3344.8262 2.3115.6222.9621.543.0463 2.2315.0722.1520.741.3564 2.1514.5421.3719.9439.7365 2.0814.0320.6219.2138.1866213.5419.918.536.767 1.9413.0819.2117.8335.2868 1.8712.6318.5517.1933.9269 1.8112.1917.9116.5732.6270 1.7511.7817.315.9731.3871 1.6911.3816.7115.430.1972 1.631116.1514.8629.0573 1.5810.6315.6114.3327.9674 1.5310.2715.0913.8326.9175 1.489.9314.5813.3425.9176 1.439.614.112.8824.9577 1.389.2913.6412.4324.03Eaton Electronics Division 1000 Eaton Boulevard Cleveland, OH 44122United States /electronics© 2022 Eaton All Rights Reserved Printed in USA Publication No. ELX1225 BU-ELX22085July 2022NRG Epoxy sealed radial lead NTC thermistor Technical Data ELX1225Effective July 2022Life Support Policy: Eaton does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user.Eaton reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Eaton also reserves the right to change or update, without notice, any technical information contained in this bulletin.Eaton is a registered trademark.All other trademarks are property of their respective owners.Follow us on social media to get thelatest product and support information.Manual solder+360 °C, 2.5 seconds maximum by soldering iron, distance between soldering position and coating 10 mm minimum.T emperature characteristics, cont.Part number NRG104 3950NRG2243700NRG1053950NRG1054120NRG2254370B type B25/50B25/50B25/50B25/50B25/50Temperature (°C)Resistance (kΩ)Resistance (kΩ)Resistance (kΩ)Resistance (kΩ)Resistance (kΩ)78 1.348.9813.191223.15791.38.6912.7611.5922.31801.268.4112.3411.221.5811.228.1411.9510.8220.72821.187.8811.5610.4519.97831.147.6311.1910.119.26841.117.3910.849.7618.57851.077.1510.499.4317.91861.04 6.9310.169.1217.28871.01 6.719.848.8216.67880.9762 6.59.548.5316.09890.9467 6.39.248.2515.53900.9183 6.118.957.9814.99910.8909 5.928.687.7214.47920.8644 5.748.417.4813.97930.8389 5.578.167.2413.49940.8143 5.47.91713.04950.7905 5.247.67 6.7812.59960.7675 5.087.44 6.5712.17970.7454 4.937.22 6.3611.76980.724 4.787 6.1611.37990.7033 4.64 6.8 5.9710.991000.6833 4.51 6.6 5.7810.631010.6639 4.37 6.4 5.6110.281020.6453 4.25 6.22 5.439.941030.6272 4.13 6.04 5.279.611040.6098 4.01 5.86 5.119.31050.5929 3.89 5.69 4.959。

格瑞达触摸芯片GRM805_10规格书_V00

格瑞达触摸芯片GRM805_10规格书_V00

2、芯片特征
电压范围:3.15V ~5.5V(-40 ℃~85 ℃) I/O 口配置: − 按键:最多可连接 12 个触摸按键; − 通讯:跟主机通讯,12 个按键串行发送; − 键按下一直发送,键抬起停止发送,主机可根据需要裁取单键或者连续键。 芯片优势: − 防水性能优良; − 抗干扰强,防辐射性能好; − 对电源要求不高,直接用 5V 供电; − 对布线要求不高; − 灵敏度分为 8 个等级可调,通过外接电阻设置; − 单线串行通讯:简单,可靠,节省主机资源; − 产品符合 ROHS 标准; − 适应多种触摸介质; − 具有方便使用的 DIP,SOP 封装。 市场反馈良好 该芯片自推出以来,广泛应用于电磁炉、油烟机、热水器、电水壶、面包机、压 力锅等小家电,市场反应良好,尤其在防水、抗干扰及稳定性方面获得很高的评价。
表51grm80510管脚说明脚位管脚名称说明k4com3按键信号输入端口4164驱动数码管com3k5com4按键信号输入端口5164驱动数码管com4k6com5按键信号输入端口6164驱动数码管com5k7com6按键信号输入端口7164驱动数码管com6k8com7按键信号输入端口8164驱动数码管com7k9按键信号输入端口9k10按键信号输入端口10k11按键信号输入端口11k12按键信号输入端口1210vss芯片电源负极11vdd芯片电源正极12rx数据接收端口13tx按键发送端口14ss2stb灵敏度选择口216x8stb口1637用不到此口15ss1clk灵敏度选择口1164时钟口16x8时钟口16dioab16x8数据口164数据17ss0灵敏度选择口018k1com0按键信号输入端口1164驱动数码管com019k2com1按键信号输入端口2164驱动数码管com120k3com2按键信号输入端口3164驱动数码管com212通道触摸按键可驱动16x8164的可编程芯片6应用设计61参考电路

REX–C410FK02温控表说明书

REX–C410FK02温控表说明书

REX–C410FK02温控表说明书产品简介:测量范围:0-1000测量精度:0.5 mm产品重量:500 g电压:220V工作环境:-10~60 mm环境温度范围:-10~60℃结构形式:单元组合式类型:智能温度控制调节器适用范围:机械,塑料输出信号:4-20 mA外形尺寸:96X48显示方式:LED品牌:RKC/理化型号:REX-C410FK02-MxAN加工定制:是外形尺寸(长x宽x高):96X48 mm详细说明:REX–C410FK02智能化数字显示调节仪采用高集成度的专用电路,同时显示测量值和设定值,全部功能均由面板选择设置,抗干扰能力强,使用方便,使数显仪表的各项性能水平有一个相当大的提高和突破,产品可广泛用于石油化工、塑料、橡胶、冶金、轻工、食品机械等行业。

产品具有性价比高,可靠性好等特点,深受广大用户欢迎。

主要特点:1、热电偶、热电阻、模拟量等多种信号自由输入、量程自由设置。

2、软件调零调满度,冷端单独测量,放大器自稳定,显示精度优于0.2%FS3、模糊理论结合传统PID方法,控制快速平稳,先进的无超调自整定方案。

主要技术指标:1、测量误差:±%±1字±0.5%±1字±0.2%±1字三档附加冷端补偿误差:≤±2℃温度系数≤0.05℃/℃2、测量数显范围:0-399℃3、报警范围:全量程自由设定4、继电器输出触点容量:3A/220V阻性或指定5、固态继电器输出信号:12V±3A 30mA6、时间比例周期:30S±10S或用户指定7、工作电源:220V±10%50HZ8、工作环境:0-50℃相对湿度≤85%RH,无腐蚀性及无强电磁幅射场合。

霍尔传感器样本手册——安科瑞 华楠

霍尔传感器样本手册——安科瑞 华楠

1.霍尔传感器霍尔电流传感器主要适用于交流、直流、脉冲等复杂信号的隔离转换,通过霍尔效应原理使变换后的信号能够直接被AD 、DSP 、PLC 、二次仪表等各种采集装置直接采集,广泛应用于电流监控及电池应用、逆变电源及太阳能电源管理系统、直流屏及直流马达驱动、电镀、焊接应用、变频器,UPS 伺服控制等系统电流信号采集和反馈控制,具有响应时间快,电流测量范围宽精度高,过载能力强,线性好,抗干扰能力强等优点。

1.1开环霍尔电流传感器1.1.1型号说明1.1.2技术指标技术参数指标霍尔开口式/闭口式开环霍尔(真有效值)输出标称值电压:±5V/±4V 电流:4~20mA 零点失调电压(电流)电压:±20mV电流:±0.05mA失调电压(电流)漂移电压:≤±1.0mV/℃电流:±0.04mA/℃线性度≤0.2%FS电源电压DC ±15V DC 24V频宽0~20kHz 响应时间≤5us≤1ms耐压强度输入与输出及电源之间允许AC2500V 工频耐压精度等级1.0环境温度工作:-25℃~+70℃;储存:-40℃~+85℃湿度≤95%RH,不结露,无腐蚀性气体场所海拔≤3500m注:开口式、闭口式为传感器产品外观不同,原理都为开环原理。

1.1.3开口式开环霍尔电流传感器1.1.3.1规格尺寸(单位:mm)图1图21.1.3.2规格参数对照表型号额定电流供电电源额定输出测量孔径(mm)准确度AHKC-EKA 0~(50-500)A ±15V 5V /4V φ201级AHKC-EKAADC 0~(50-500)A12V/24V4~20mAφ201级尺寸规格外形尺寸穿孔尺寸安装尺寸图形W H D a e ΦM N AHKC-EKA 606416//2047/图1AHKC-EKAA 606416//2047/图1AHKC-EKDA 606416//2047/图1AHKC-EKB 10010224//4080/图1AHKC-EKBA 10010224//4080/图1AHKC-EKBDA 10010224//4080/图1AHKC-EKC 11511027//6095.5/图1AHKC-EKCA 11511027//6095.5/图1AHKC-EKCDA 11511027//6095.5/图1AHKC-K 12763256416//30图2AHKC-KAA 12763256416//30图2AHKC-KDA 12763256416//30图2AHKC-H 14979258232//46图2AHKC-KA 17695.52910436//60图2AHKC-HB 204111.52913252//48×2图2AHKC-HBAA 204111.52913252//48×2图2AHKC-HBDA204111.52913252//48×2图2AHKC-EKDA AC 0~(50-500)A 12V/24V 4~20mA φ201级AHKC-EKB 0~(200-1000)A±15V 5V /4V φ401级AHKC-EKBADC 0~(200-1000)A 12V/24V4~20mAφ401级AHKC-EKBDA AC 0~(200~1000)A 12V/24V 4~20mA φ401级AHKC-EKC 0~(500-1500)A±15V 5V /4V φ551级AHKC-EKCADC 0~(500-1500)A 12V/24V4~20mAφ551级AHKC-EKCDA AC 0~(500-1500)A 12V/24V 4~20mA φ551级AHKC-K 0~(400-2000)A±15V 5V /4V 64×161级AHKC-KAA DC 0~(400-2000)A 12V/24V4~20mA64×161级AHKC-KDAAC 0~(400-2000)A12V/24V 4~20mA 64×161级AHKC-H 0~(500-3000)A ±15V 5V /4V 82×321级AHKC-KA 0~(500-5000)A±15V 5V /4V 104×361级AHKC-HB0~(2000-20000)A±15V5V /4V132×521级AHKC-HBAA DC 0~(2000-20000)A12V/24V 4~20mA 132×521级AHKC-HBDA AC 0~(2000-20000)A12V/24V 4~20mA 132×521级注:额定电流未标注表示输入电流交直流均可测量,订货时请注明。

h05rn-f标准

h05rn-f标准

h05rn-f标准
H05RN-F是一种橡胶线,该标准主要用于连接无线电设备。

该标准规定了电缆的电气性能、机械性能和环境性能等方面的要求,以确保电缆在各种条件下能够可靠地传输信号和电力。

此标准对电缆的电阻值、绝缘电阻、传输延迟、频率响应等方面都有严格的要求,以确保信号在传输过程中的稳定性和可靠性。

此外,H05RN-F还具有高灵活性、防晒、防水、防油、耐温、耐寒、抗UV、抗老化、阻燃等特性,应用广泛,包括处理设备、移动电源、工地、舞台和视听设备,港口地区和水坝等。

如需更多关于H05RN-F标准的信息,建议直接联系相关的行业组织或标准制定机构,或者查阅最新的官方资料。

CDRH104RNP-2R5NC中文资料

CDRH104RNP-2R5NC中文资料

About Lead-free products / 無鉛製品について
. . . .
Lead-free products are now available for sale To order a lead-free product, please add"NP" after the product type: 無鉛製品は現在、販売されております。 ご注文の際は製品タイプ名の後に”NP”をつけてください。
Measuring Freq. (L) / インダクタンス測定周波数(L) CDRH104R 100 kHz
Tolerance of Inductance / インダクタンス公差 CDRH104R 1.5 µ H – 330 µ H ± 30%(N)
Other / その他 *C Saturation Rated Current : The current when the inductance becomes 35% lower than its nominal value. (Ta=20°C) *C 直流重畳許容電流直流重畳許容電流を流した時、 インダクタンスが公称インダクタンスの65%以 : 上となる電流値とする。(Ta=20℃) * II Temperature Rise Rated Current : The current when temperature of coil increases up to Max. ∆T=30°C. (Ta=20°C) * II 温度上昇許容電流 直流電流を流した時、 : コイルの温度上昇がΔT=30℃以下となる電流値と する。(Ta=20℃)
Rev1.0 09/2004
e.g. Ordering code of lead product: Type name-△△△○× Ordering code of lead-free product: Type name NP△△△○×

RKC CH102 说明书

RKC CH102 说明书

RKC CH102 说明书文章来源:/数字控制器CH系统操作手册1.产品型号说明①控制:F:PID动作及自动计数(逆向动作) D:PID动作及自动计数(直接动作)②输入方式③范围代码:参考8输入范围表*④第一控制输出(OUT1)(加热侧):M:继电器输出 T:三端双向可控开关 V:电压脉冲 B:电流(4到20毫安直流)G:过零(用于三端双向可控驱动)⑤第二控制输出(OUT2)(制冷侧)⑥警报输出[ALM1]N:没有警报 A:高偏差警报 B:低偏差警报 C:偏差高/低警报 D:联合警报 E:高偏差警报并持续F:低偏差警报并持续 G:偏差高/低警报并持续 H:高进度警报 L:低进度警报并持续 J:低进度警报K:高进度警报并持续7:警报输出[ALM1]N:没有警报 A:高偏差警报 B:低偏差警报 C:偏差高/低警报 D:联合警报 E:高偏差警报并持续F:低偏差警报并持续 G:偏差高/低警报并持续 H:高进度警报 L:低进度警报并持续 J:低进度警报K:高进度警报并持续8:交流功能:N:无交流功能 5:RS-485(2-线系统)9:防水防尘结构:N:无防水/防尘结构 1:防水/防尘结构2.安装2.1 安装条件※环境温度不低于0度或不超过50度※环境湿度不低于45%或不超过85%RH※无腐蚀或易燃气体。

※无水、油、化学品、蒸汽飞溅的地方※无过多感应燥音,静电,磁场。

※无热凝聚形成热辐射2.2 尺寸3.警告3.1 接线注意事项(1)对于热电偶输入的,使用特定的补偿线。

(2)对于热电阻输入的,使用低电阻线,并且三个线头间不带电阻差。

(3)将输入信号线绕开仪表电源,电气设备电源及负荷线以防止燥音感应。

(4)对于电流输入,必须由输入端提供一个250欧的电阻器(±0.02%±10ppnm,0.25W)。

3.2 仪表接线电源供给电压:90至264V交流电50/60HZ 、≤7W警报输出等级:继电器联接输出:250伏交流电,1安(电阻性负载)控制输出等级:继电器联接输出:250伏交流电,3安(电阻性负载)电压脉冲输出:0/12伏直流电(负荷电阻600欧或更多)电流输出:4至20MA直流电(负荷电阻600欧或更少)过零输出(用于三端双向控制驱动):过零触发用4.面板说明1)所测数值(PV)显示单元:显示所测得的数值(PV)、显示仪表的不同参数标记2)设置数值(SV)显示单元:显示设置的数值(SV)、显示仪表的不同设置参数3)指示灯**自动整定指示灯(AT),在自动整定时闪烁控制输出指示灯(OUT1),在控制输出打开时亮警报输出指示灯(ALM1),在警报时亮辅助输出指示灯(OUT2),在辅助输出打开时亮4)设置键(SET):用于输入/调出参数,按二秒以上可以读出表二数据5)转换和R/S键(R/S):在设置改变时转换数字(转换键),用于选择运行/停止功能6)下降键:用于降低数字7)上升键:用于升高数字5.显示模式状态5.1每个模式的开启程序打开电源→显示输入方式→显示输入范围(大约显示4秒钟)→如果按键后没有反应的时间超过1分钟,仪表回复到PV/SV 显示模式状态。

加温器双通道参数

加温器双通道参数

加温器双通道参数
性能:
1.1双加温通道,每个通道可独立设定温度和恒温加热
1.2双加温通道串联使用可满足大流量加温需要
1.3 大屏幕显示,可显示设定温度,加热温度,加热时间,故障信息
1.4 柔性加热套管结构,全程包裹液体管路,液体管路无裸露部分,加热后液
体直达患者,热量不流失,适合寒冷环境使用
1.5干式加热法,预热时间短,加热迅速
1.6使用常规输血输液管路,无需专用耗材
1.7仪器可用于急救场合,电气安全符合GB9706.1-2007标准要求,为防除颤保护级别
1.8仪器可用于手术室和监护室,符合YY0505-2012电磁兼容标准,防止仪
器间的相互干扰
参数
2.1 温度设定范围:33-41℃
2.2电气安全保护级别:I类BF型,防除颤保护
2.3温度精度:±1℃
2.4超温断电保护:42℃
2.5低温报警:32℃
2.6预热时间:从20℃-36℃约2分钟
2.7工作制:连续运行
2.8加热管: 1.4米,适用于直径
3.5-5mm输血输液管路。

InspireX R50G 高速X射线检测仪产品说明书

InspireX R50G 高速X射线检测仪产品说明书

I n s p e c c i ón p o r r a y o s XInspección integral de vidrio en vidrio2Los sistemas de rayos X InspireX R50G ofrecen una inspección automática óptima de tarros de vidrio de densidad alta y media. Permite una detección excepcional de cuerpos extraños, como vidrio de material férrico, no férrico y de aceroinoxidable, piedras minerales, huesos calcificados y plásticos de alta densidad. Asimismo, puede realizar simultáneamente un gran número de controles de calidad en línea, incluida la supervisión del nivel de llenado.I n s p e c c i ón p o r r a y o s XInspireX R50GInspección integral de vidrio en vidrioFunciones de software•Las herramientas de software XTP recientemente desarrolladas analizan los productos con la mayor resolución posible y, de esta forma, permiten alcanzar unos niveles de deteccióninsuperables, sobre todo en las zonas más complicadas de los envases de vidrio.•Configuración completamente automatizada que garantiza un máximo tiempo de funcionamiento de la producción.•El filtrado a medida permite que los filtros de perfil exterior de los envases cambien de forma dinámica para cada envase, lo que garantiza una detección óptima y un mínimo de falsos rechazos.•ProdX: las opciones del software de gestión de datos de inspección de productos proporcionan una gran cantidad de información en tiempo real para la gestión de la producción, lo que permite el control eficaz de los dispositivos y procesos de inspección de productos.Diseño e higiene•Diseño higiénico puntero en su categoría, según las pautas GMP , NSF y EHEDG.•IP65 de serie e IP69K disponible como opción para entornos hostiles de lavado.•Fácil acceso a todas las zonas de la máquina, sin recovecos proclives a la proliferación de bacterias, lo que garantiza un tiempo de inactividad mínimo y una protección óptima frente a microorganismos patógenos.• Allí donde era posible, se han colocado superficies inclinadas para evacuar el agua.Flexibilidad y seguridad•Generador de rayos X de 360 W para una amplia gama de envases de vidrio.•La velocidad de exploración con rayos X se sincroniza automáticamente con lavelocidad de la cinta del cliente, manteniendo una relación de imagen de uno a uno. No se requiere ningún ajuste manual, lo que garantiza el máximo tiempo de funcionamiento de la línea de producción, así como la optimización de la detección y del rechazo.Auditorías y verificación•Trazabilidad estadística completa para creación de informes de calidad.• Las imágenes y las estadísticas se guardan tras el apagado, lo que garantiza el mantenimiento de datos sensibles.•Verificación del rendimiento integrada para garantizar un rendimiento óptimo de forma continua.•Todos los informes e imágenes se pueden descargar a un dispositivo USB o a través de una red, por lo que no hay necesidad de conservar registros en papel.•Las opciones de confirmación de rechazo y de alarma de contenedor lleno garantizan una eficacia del 100 % en el rechazo de la línea.Instalación rápida, fácil y rentable•Sistema completamente integrado que incluye la transferencia, la inspección y el transportador de rechazos, lo que hace que el tiempo de instalación y el coste total de propiedad se reduzcan considerablemente.•InspireX R50G se suministra con el haz de rayos X prealineado con el transportador de rayos X integrado, de tal manera que tan solo es necesario realizar un mínimo alineamiento con el transportador del cliente.•Las emisiones de rayos X semantienen dentro de la estructura, lo que hace innecesario el uso de pantallas de protección adicionales en el transportador del cliente.Software de gestión y control de datos Prod X .3El sistema de inspección por rayos X InspireX R50G no tiene rival en la inspección vidrio en vidrio, ya que elimina los puntos ciegos tradicionales de la base, de las paredes laterales y del cuerpo de los envases de vidrio, además de ofrecer comprobaciones precisas del nivel de llenado de altura máxima. Asimismo, optimiza la eficiencia de la línea de producción y contribuye a que los fabricantes de alimentos se pongan por delante de sus competidores, al mismo tiempo que garantiza el cumplimiento de la normativa y demuestra la diligencia debida.El transportador de transferencia en tres etapas InspireX R50G permite transferir con fluidez el producto desde el transportador del cliente hasta el transportador principal de rayos X.Vista frontal de InspireX R50G.Diagrama del haz de InspireX R50G, que muestra dos ejemplos deanchuras y alturas de tarro diferentes.Imagen de rayos X que muestra la detección de vidrio de 2,5 mm en la base del tarro.Imagen de rayos X que muestra la detección de vidrio de 2 mm en las paredes laterales del tarro.Imagen de rayos X que muestra una inspección precisa del nivel de llenado.InspireX R50GPara más informaciónMettler-Toledo S.A.E.Miguel Hernández, 69-7108908 L’Hospitalet de Llobregat Barcelona, EspañaTel.: +34 902 32 00 23Fax: +34 902 32 00 24Correoelectrónico:*************Sujeto a cambios técnicos.© 05/2013 Mettler-Toledo Safeline X-ray Ltd.Impreso en el Reino Unido./safeline-xrayTabla de especificacionesHay varios tipos disponibles de sistemas de rechazo de alta velocidad completamente integrados.La elección correcta depende de varios factores, como el tipo de entorno, la velocidad de la cinta y el peso, el tipo y el tamaño del envase. Todos los sistemas de rechazo disponen de verificación de rechazo opcional, que garantiza que un producto defectuoso acaba en el contenedor de rechazo y verifica que el sistema de rechazo funciona.Mecanismos de rechazoSistema de rechazo de empujador lateral de cortoalcance de alta velocidad.。

HM315R技术参数

HM315R技术参数

HM315R(新)轮转式石蜡切片机详细参数
•100%德国原装机械式轮转切片机
•以高精度和高稳定性著称,切片厚度范围0.5-60u,是同类仪器达到最先进的精度指标。

•本类仪器又具有杰出的人机工程学特点,可拆卸的活动式碎屑槽是Microm的独特设计。

•手轮切片非常轻巧
•Microm对该类切片机建立了最高质量的新标准,具有最佳性价比
详细技术参数说明:
•*切片精度高0.5-60微米;
步进增幅:
•0.5u(0.5-2u)
•1u(1-10u)
•2u(10-20u)
•5u(20-60u)
•自动修片模式:10/30u两档
•手轮轻巧
•大容量切屑槽
•技术参数:
•全密封的机械系统,可提高仪器的稳定性;
•免维护的交叉滚珠导轨;
•粗动样品推进(左右手可选)
•样品回缩功能(retracrion),可开/关。

•样品水平进样:28mm
•样品水平进样:64mm
•手轮可在任何位置锁定;
•样品头XY精细位
•样品夹转动功能360°
•各种样品夹头可快速互换;
•大容量切屑槽(1100ml);
•尺寸:420×490×280mm
•重量:23kg
•一次性刀片:
•SEC 35由高质量钢使用双涂层
•各种附件,提高使用的灵活性
同类产品比较。

h05rnf标准

h05rnf标准

h05rn-f标准
H05RN-F是一种欧洲标准的电缆型号,用于低电压移动设备
和工具的供电连接。

以下是关于H05RN-F标准的详细描述:
1. 标准名称:H05RN-F
2. 适用范围:H05RN-F电缆适用于低电压(最高750V)移
动设备和工具的供电连接,如移动灯具、小型电动工具、
家用电器等。

3. 导体材料:H05RN-F电缆的导体通常由铜制成,以提供
良好的电导性能。

4. 绝缘材料:H05RN-F电缆的绝缘层通常采用聚氯乙烯(PVC)材料制成,以提供良好的绝缘性能。

5. 外护套材料:H05RN-F电缆的外护套通常采用聚氯乙烯(PVC)材料制成,以提供保护导体和绝缘层的功能。

6. 颜色编码:H05RN-F电缆的导体通常采用以下颜色编码:蓝色(N线)、棕色(L线)、绿黄色(PE线)。

7. 额定电压:H05RN-F电缆的额定电压为300/500V或
450/750V,取决于具体的型号和规格。

8. 额定温度:H05RN-F电缆的额定温度为最高70℃。

9. 弯曲半径:H05RN-F电缆的弯曲半径应不小于电缆外径
的6倍,以确保电缆在弯曲时不受损。

10. 标准符合性:H05RN-F电缆符合欧洲标准EN 50525-2-
21和IEC 60245-4,以确保其质量和性能符合国际标准。

总之,H05RN-F是一种用于低电压移动设备和工具供电连接
的电缆型号,具有良好的导电性能、绝缘性能和耐热性能。

它符合欧洲标准,可广泛应用于各种移动设备和工具的电
气连接。

产品单页介绍

产品单页介绍

产品单页介绍—F1210文档编号:SPI-F1210-REV01-2010产品型号:F1210产品名称:数字DC/RMS高斯/特斯拉计生产商:北京乐真科技有限公司地址:北京市海淀区紫竹院南路18号138室,100048电话:86-10-88415205 传真:86-10-88415205网址: 邮箱:sales@保修服务:1年有限保修服务校准服务:1次免费校准计量服务:非强制计量产品、付费开具计量证书使用标准:GB-1002、IEC 825-1产品特点:◆直流测量∙测量范围±3.2000T(±32000G)DC∙显示分辨率4 2/3位、1G@±32000G∙准确度:多点线性校正、±(1%读数+15G)@ 0—0.5T◆交流测量∙真有效值RMS测量、10Hz—5kHz、CF<5、准确度优于5%∙测量范围:有效10—10500G、额定100—10500G、分辨率1G◆霍尔探头∙通用免校准数字化霍尔探头,温度系数<-0.04%/o C∙探头自动校零功能◆交互能力∙蓝色背光FSTN LCD显示器∙与显示器和指示器配合的7键交互型功能键盘操作◆数学计算∙最大值保持∙ G、T单位变换◆标准规格∙提供用户手册、快速参考手册、编程手册和接口测试程序∙小尺寸台式仪器,交流220V/50Hz供电标准配置:◆仪器F1210 数字高斯/特斯拉计1台◆探头F12001 数字化横向霍尔探头1只◆附件CAB-AC220-2 3芯交流220V电源线2m 1条FUSE5G-25020 250V/0.2A玻封保险管,5⨯20mm 2只◆文档MAN-F1210 用户手册1册S INGLE P AGE I NTRODUCTION - F1210Document Number:SPI-F1210-REV01-2010Model:F1210Name:Digital DC/RMS Gauss/Tesla MeterManufacturer: Reference Devices Co. Ltd. Suite 138, No. 18, South Road of Zizhuyuan,Haidian District, Beijing, 100048TEL: 86-10-88415205 FAX: 86-10-88415205Website: Email: sales@Warranty:Limited warranty for a period of 1 year from deliveryCalibration: Free for the first time calibrationMeasuration:Without force measuration product, payment for Certification of ChinaStandard:Follows GB-1002, IEC 825-1Specification:◆ DC Measurement ∙ Range of ±3.2000T (±32000G) DC∙ Display resolution of 4 2/3 digit, 1G@±32000G∙ Accuracy of ±(1% READ+15G) @ 0-0.5T◆ AC Measurement ∙ True RMS, 10Hz-5kHz, CF<5, 5% Accuracy, 1G resolution∙ Efficient Range of 10-10500G, Rated Range of 100-10500G◆ Probe ∙ Interchangeable digital hall probe, TR<-0.04%/o C∙ Probe auto zero function◆ Human Interface ∙ FSTN LCD display with blue back lighting∙ 7-key functional keyboard operation◆ Math Functions ∙ Max hold∙ G, T unit conversion◆ Standard Spec. ∙ Documents∙ Small size desktop instrument, AC 220V/50Hz supplyStandard Configuration:◆ Instruments F1210 Digital Gauss/Tesla Meter 1◆ Probes F12001 Digital transverse hall probe 1◆ Accessories CAB-AC220-2 AC220V 3-conductor power cord 1of 2m longFUSE5G-25020 Fuse of 250V/0.2A, 5⨯20mm 2◆ Documents MAN-F1210 User’s Manual 1。

Cres Cor 1000-CH 系列电子辐射炉用户手册说明书

Cres Cor 1000-CH 系列电子辐射炉用户手册说明书

INSTALLATION, OPERATION and MAINTENANCEMANUAL for Cres Cor RADIANT OVENSOvens FL-2340-DRev. 0 (5/13)Page 1 of 125925 Heisley Road • Mentor, OH 44060-18331000-CH-SS-D 1000-CH-AL-D1000-CH-SS-SPLIT-D 1000-CH-AL-SPLIT-D 1000-CH-SS-SPLIT-D120Models: 1000-CH-D SERIESCabinet model number:Cabinet serial number: Authorized Service Agency:Ph:Fax:Keep this manual for future reference.Ovens FL-2340-DRev. 0 (5/13)Page 2 of 125925 Heisley Road • Mentor, OH 44060-1833TABLE OF CONTENTSPAGE SUBJECTINSTALLATION INSTRUCTIONS ......................................................................................3, 4 OPERATING INSTRUCTIONS ............................................................................................5, 6 Illustration, Control Panel ............................................................................................5, 6 MAINTENANCE INSTRUCTIONSHow to Clean the Unit (7)Trouble Shooting Guide (8)Replacement Parts (9)Illustration; Ovens (9)Wiring Diagram for 1000-CH-SS or 1000-CH-AL ......................................................11, 12 Wiring Diagram for 1000-CH-SPLIT .. (13)SERVICE POLICY and AGENCY LIST .........................................................................FL-1400Ovens FL-2340-DRev. 0 (5/13)Page 3 of 12 5925 Heisley Road • Mentor, OH 44060-1833INSTALLATION INSTRUCTIONSVENTING YOUR OVEN:1. The purpose of ventilating hoods is to direct andcapture smoke, grease-laden vapors, heat, odors, or fumes.2. Low temperature equipment (maximumtemperature 250°F/121°C) does not produce heat, odors, fumes, grease-laden vapors or smoke and is not required to be vented.3. Most jurisdictions consider our low-temperature ovens (maximum temperature is 350°F/177°C) as low-heat appliances not requiring vent hoods. 4. Installation must conform with local codes. The authority having jurisdiction of enforcement of the codes will have the responsibility for making interpretations of the rules.SPECIFICATIONS: All units are rated 3000 watts.CMP MODEL NOS.ELECTRICAL SPECS(AC SERVICE)ELEC. LOAD POWER SUPPLY REQUIREMENT SINGLE OVENS Volts Ph Hz.Amps Volts Amps Ph Wire Volts NEMA1000CHSSSPLITD 1000CHALSPLITD 2082401160601413208240202011222082406-20P6-20P1000CHSSSPLITD3 1000CHALSPLITD32082403360608720824020203333208240L15-20PL15-20PSPECIFICATIONS: All units are rated 6000 watts. *For USA Only - Canadian is 6-50P CMP MODEL NOS.ELECTRICAL SPECS(AC SERVICE)ELEC. LOAD POWER SUPPLY REQUIREMENT DOUBLE OVENS Volts Ph Hz.Amps Volts Amps Ph Wire Volts NEMA1000CHSSD 1000CHSS2D 1000CHALD 208240116060292520824030301122208240*6-30P*6-30P1000CHSSD3 1000CHSS2D3 1000CHALD3208240336060161420824020203333208240L15-20PL15-20PSPECIFICATIONS: All units are rated 2000 watts.CMP MODEL NOS.ELECTRICAL SPECS(AC SERVICE)ELEC. LOAD POWER SUPPLY REQUIREMENT SINGLE OVENS Volts Ph Hz.Amps Volts Amps Ph Wire Volts NEMA 1000CHSSSPLITD12012016016.612020121205-20P Model number “AL” is aluminum outer body with stainless steel doors and interior.All models designed for AC Service. Model number may include a variety of informational suffix letters.NOTE: OVENS NEED TO BE INSTALLED BY A QUALIFIED PERSON.For models rated at 2/08/240 V olts:Check the voltage selector switch which is under an access cover on the back of the oven near the power cord. Flip the switch “UP” for 208 V olts Flip the switch “DOWN” for 240 V olts MAKE SURE THE SWITCH POSITION MATCHES YOUR POWER SOURCE.Ovens FL-2340-DRev. 0 (5/13)Page 4 of 125925 Heisley Road • Mentor, OH 44060-1833HOW TO INSTALL CABINETS:1. Remove all packing material from the inside and all vinyl from the outside of oven.2. Place the oven in a well ventilated area on level floor. Clearance requirements: 3” (76mm) at the back, 2” (51mm) at the top, 1” (25mm) at both sides.3. Install the pan slide racks on the sidewalls, if necessary.4. Slide drip pan(s) onto the bottom of the compartment(s).All models are rated at 208/240 V olts.INSTALLATION INSTRUCTIONS (continued)HOW TO REVERSE THE DOOR OPENINGS, IF NEEDED:1. Unscrew and remove the latch from the door and magnetic strike from the cabinet.2. Unscrew the hinges from the cabinet body and remove door.3. Remove the screws plugging the mating hinge, latch and strike holes on the opposite sides of the cabinet body and door.4. Re-mount the hinges to the opposite side of the cabinet and door.5. Remount the latch and strike to the opposite sideFOR FIRST-TIME OPERATION ONLY:A new oven needs to “burn off” factory oils and glue before it’s first use. Do NOT load food into oven until this has been done!1. Push switch to “ON”; the light will come on.NOTE: The letters “LOTPR” (low temperature) will showon the control panel until it reaches 140°F (60°C).2. Press the “COOK” button.3. Push down and turn the control knob to show 200°F. Push the knob again to set the temperature. Run the unit for one (1) hour.4. Turn the unit off and let cool.5. Wipe the inside clean with detergent and hot water.DOOR VENT ADJUSTMENT:Open the door(s) and move the vent tabs on the inner door(s) as needed to release humidity.Air is VERY HOT when door is opened.IDENTIFYING YOUR CABINET:Look for this label on the back of your cabinet. This information is needed when calling for questions or service.OPERATING INSTRUCTIONSHOW TO USE THE COOK-N-HOLD CONTROL: *Push the lighted switch on the control panel; the light willcome on and the cabinet will start heating.*The display will read “LOTPR” (low temperature) below 140°F. (60°C.).NOTE: Wait one (1) hour after start up before loading the food for best results.The display will read “PREHT” until the cabinet reaches the set temperature, then it will show “READY”. Cooking:1. Press the COOK button.2. Turn the control knob to the desired cookingtemperature between 200°F (93°C) and 350°F (176°C).3. Push the knob to set the temperature.4. The control automatically goes to the HOLD mode.(Continue to step 1 below).Holding:(Press the HOLD button only if you are just holding food), 1. Turn the control knob to the desired holding temperaturebetween 140°F (60°C) and 220°F (104°C).2. Push the knob to set the temperature.3. The control automatically goes to the TIME mode.Setting the time or Food Probe:1. If NOT using the Food Probe:a) Turn the control knob to the desired hours/minutes.b) Push the knob to set the time.2. Using the Food Probe:Plug in the food probe BEFORE you enter the TIMEmode. Otherwise, you have to press the PROBE button to set the probe temperature.a) Turn the knob to the desired temperature.b) The timer will stop when the probe reaches the settemperature.3. Press the START button. The display will read“PREHT” until the cabinet reaches the set temperature, then it will show “READY”.4. Press the START again to use this recipe (see Recipes”). Note: Press the knob for 4 seconds to cancel the recipe. The DISPLAY button shows (cycles through) all the values when in each mode:• “PREHEAT” OR “READY”: momentarily shows the actual cabinet temperature.• “COOK” (Timed): shows Home screen, set point, count down time, actual cabinet temperature.• “COOK” (Probe): shows Home screen, set point, count up time, actual cabinet temperature.• “HOLD”: shows Home screen, set point, count uptime, actual cabinet temperature.RECIPES:The control can hold up to 18 saved recipes.To save a recipe:1. Press and hold both the TIME button and the knob for5 seconds. The screen will be flashing. This is the setupmenu.2. Turn the knob through the menu until you get to “Edit”.3. Press the knob and turn to the recipe you want to edit.There are 18 blank recipes to customize and save.4. Press the knob and enter the cook, hold and time values.5. After the entering the final value, “Edit” will showagain.6. Press the knob to edit more recipes or turn to “End” toexit the menu.To use one of the recipes:1. Push one of the three RECIPE group buttons for therecipe number you want.2. Turn the knob to the recipe you want and press the knobto select.3. Press the START button to preheat.4. After it shows “READY”, press the START buttonagain to begin the recipe.Note: The display button will cycle through all the values as before, but will include the recipe number, ifusing a saved recipe.Quick Recipe Note:You can set “Quick Recipes” for recipes that you use often. This way, when you press a recipe group button and press start, that recipe will start cooking without searchingfor the recipe number. Recipe numbers can be set up as “quick recipes” as follows:1. Press and hold both the TIME button and the knob for 5seconds to get into the menu.2. Turn the knob to “RBTN” and press the knob. The word“PUSH” will flash.3. Press one of the recipe group buttons to assign a recipe. Note: Recipe numbers 1-6 can be set up as Group button 1.Recipe numbers 7-12 can be set up as Group button 2.Recipe numbers 13-18 can be set up as Group button 3.4. Turn the knob to the recipe number you want to assignto that button and press the knob.Repeat the process to assign recipes to the other two recipe group buttons; or,turn the knob to “END” the submenu; turn to “END” the menu.Additional Menu Settings:Press and hold both the TIME button and the knob for 5 seconds to get into the menu.Here you can set the recipes, quick recipes, temperature units (°C or °F) and the datalogsettings (USB connection required):”RECE” allows you to enable or disable the data record feature.“RECF” allows you set how often (in minutes) a datapoint will be recorded.“RECD” allows you to set how long (in days) you wouldlike the data to be stored in memory.Ovens FL-2340-DRev. 0 (5/13)Page 7 of 125925 Heisley Road • Mentor, OH 44060-1833BEFORE cleaning the cabinet:1. Unplug cord from wall. Allow cabinet to cool.2. Do NOT hose cabinet with water.3. Do NOT get water on controls.4. Do NOT use abrasives or harsh chemicals.⏹ Wipe up spills as soon as possible.⏹ Clean regularly to avoid heavy dirt build-up.Cleaning Hints:1. Use the mildest cleaning procedure that will do the job.2. Always rub in the direction of polish lines to avoid scratching the surface.3. Use only a soft cloth, sponge, fibrous brushes, plastic or stainless steel pads for cleaning and scouring.4. Rinse thoroughly with fresh water after every cleaningoperation. 5. Always wipe dry to avoid water marks.MODELS: 1000-CH-SS-D & 1000-CH-SS-SPLIT-DSOILCLEANERMETHODSTAINLESS STEEL CABINET Inside and OutsideRoutine CleaningSoap or mild detergent* and water.1. Sponge on with cloth2. RinseStubborn Spots, Stains Mild abrasive made for Stainless Steel.1. Apply with damp sponge or cloth.2. Rub lightly.Burnt on Foods or Grease Chemical oven cleaner made for Stainless Steel.Follow oven cleaner manufacturer’s directions.Hard Water Spots & ScaleVinegar1. Swab or wipe with cloth.2. Rinse and dry.HOW TO CLEAN THE UNIT:MODELS: 1000-CH-AL-D & 1000-CH-AL-SPLIT-D(Aluminum cabinet outside only with stainless steel doors and pan slides)SOILCLEANERMETHODALUMINUM CABINET Outer body ONLYDirtMild detergent* and hot water, or mild abrasive cleaner. 1. Use soft, damp cloth.2. Rinse with hot water.3. Wipe dry.Steam (no strong alkaline additive).1. Rinse after steam cleaning.2. Wipe dry.Fingerprints, Grease, OilDetergent* and hot water. 1. Wipe with soft, damp cloth.2. Rinse with hot water.3. Wipe dry.Chemical oven cleaner made for aluminum.Follow oven cleaner manufacturer’s directionsMild abrasive cleaner.Oily or waxy cleaner.Apply with soft, clean cloth.Water SpotsMild abrasive cleaner.Wipe with damp cloth.*Mild detergents include soaps and non-abrasive cleaners.Ovens FL-2340-DRev. 0 (5/13)Page 8 of 12 5925 Heisley Road • Mentor, OH 44060-1833MAINTENANCE INSTRUCTIONSTROUBLE-SHOOTING GUIDE1. Cord is unplugged from wall outlet.2. Circuit breaker/fuse to wall outlet is blown.3. Switch(es) are turned off.4. Thermostat(s) are turned off, or are set too low.If hot unit is NOT working, first check the following causes: IF THE OVEN TURNS ON:PROBLEM POSSIBLE CAUSE SOLUTIONOven does not heat, or doesn’t heat properly 1. Sensor2. Heater relay3. Loose connection4. Oven control5. High Limit1. Replace2. Replace3. Replace4. Replace5. ReplaceHeater will not shut off 1. Control defective2. Heater relay1. Replace2. ReplaceVent fans do not shut off 1. Vent fan switch defective2. Control compartment is still hot.1. Replace2. Wait until it coolsCheck “Heater will not shut off”Vent fans do not operate (See Note)1. Vent fan switch defective2. Vent fan defective1. Replace2. ReplaceControl will not switch from “COOK” to “HOLD” (timed mode)1. Oven is in “PROBE” mode.2. Oven control defective1. Cancel recipe and switch to “TIMED” mode2. ReplaceControl will not switch from “COOK” to “HOLD” (probe mode)1. Oven is in the “TIMED” mode2. Probe not plugged in3. Probe defective4. Oven control defective1. Cancel recipe and switch to “PROBE” mode2. Plug in probe3. Replace4. ReplaceControl will not switch to “COOK” (probe mode)1. Oven in “TIMED” mode2. Probe temperature setting lowerthan probe temperature3. Probe not plugged in4. Oven control defective1. Switch to “PROBE” mode2. Set probe temperature to desired temperature3. Plug in probe4. ReplaceERROR CODES:CODE DISPLAYED CAUSE SOLUTIONno p No meat probe Plug in probeErr0Temp probe bad ReplaceNOTE: Vent fans will not operate until the control compartment requires ventilation to limit temperatures. Replacement of electrical components must be done by a qualified electrician.Refer to our Service Agency list, FL-1400 (found in the back of this manual), of authorized service centers.Instructions for replacing parts are included in replacement parts list.Ovens FL-2340-DRev. 0 (5/13)Page 9 of 125925 Heisley Road • Mentor, OH 44060-1833REPLACEMENT PARTSInclude all information on nameplate when ordering partsModel 1000-CH-SS-D is shown.Model 1000-CH-SPLIT-D ishalf-size single door oven.Ovens FL-2340-DRev. 0 (5/13)Page 10 of 12 5925 Heisley Road • Mentor, OH 44060-1833REPLACEMENT PARTSInclude all information on nameplate when ordering partsITEM DESCRIPTION CMP Part No.1. Switch (On/Off)0808-1252. Digital Control0848-092-08-K3. Switch, Fan0848-0344. Relay (1000-SPLIT-D)0857-136Relay (1000-SS-D)0857-1345. Terminal Block (Input)0852-1096. Terminal Block0852-0917. Switch, toggle (240V)0808-0208. Vent Fan (240V)0769-174Vent Fan (120V)0769-1659. Fan Guard0769-16710. Heater Kit 240V, 1325W0811-296-K Heater Kit 120V, 1000W0811-295-K11. Door Latch Kit1006-122-01-K12. Latch Strike Kit1006-122-02-K13. Door Assembly1221-573-K14. Door Gasket0861-26715. Door Hinge0519-10916. Casters, Rigid0569-306-R ITEM DESCRIPTION CMP Part No.17. Casters w/Brake0569-306-B18. Pan Slides0692-20019. Drip Pan1017-11520. Hi-Limit0848-03321. Drip Tray1017-11122. Wire Shelf1170-21223. Power Cord (3000W, 1Ph)0810-173-01-K Power Cord (6000W, 1Ph)0810-163-01-K Power Cord (3000W, 3Ph)0810-164-02 Power Cord (6000W, 3Ph)0810-164-01 Power Cord (2000W, 1Ph)0810-065-124. Strain Relief0818-05025. Clear Drip Pan1017-05826. Transformer0769-19727. Fuse (1000-SS-D)0807-15028. Fuse Holder (1000-SS-D)0807-15129. Strainer1052-094Probe-Food 6”0848-103Probe Connector0848-106-02OvensFL-2340-DRev. 0 (5/13)Page 11 of 12Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • 5925 Heisley Road • Mentor, OH 44060-1833WIRING DIAGRAM FOR 1000-CH-D SERIEST R I A DW H I T EB L AC KB L U EB R O W NG R A YY E L L O WP U R P L ER E DT O PT R I A DW H I T EB L AC KB L U EB R O W NG R A YY E L L O WP U R P L E R E DB O T T O MB o t t o mC o n t r o l C o m p a r t m e n tf u s ef u s et o p h e a t e r sb o t t o m h e a t e r sT r a n s f o r m e rT r a n s f o r m e rK 3 K 1 K 2R E N A U C O N T R O LT O P C A B I N E T L O O K I N G A T R E A RN N LL t °t °M E A T P R O B E A I R P R O B EL 1 T 1A 2(-) A 1(+)L 1 T 1A 2(-) A 1(+)H I G H L I M I TH I G H L I M I TV E N T F A NV E N T F A NK 3 K 1 K 2R E N A U C O N T R O LB O T T O MC A B I N E T L O O K I N G A T R E A Rt °t °M E A T P R O B EA I R P R OB EN N LL H I G H T E M P c l o s e s @130FT B 1T B 2T B 3S S R B O T T O MS S R T O P P o w e r S w i t c h P o w e r S w i t c hB o t t o mT o p1122334455678899101011111212131314141515161617181718191920202122222323242525242627262728293031t o p c a b i n e tb o t t o mc a b i n e t28293031208V /240V S w i t c h 32323333343435351615141312111098765432116151413121110987654321OvensFL-2340-DRev. 0 (5/13)Page 12 of 12Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • 5925 Heisley Road • Mentor, OH 44060-1833WIRING DIAGRAM FOR1000-CH-SS-SPLIT-D and 1000-CH-SS-SPLITD120P O W E R S W I T C H (r e a r v i e w )N N LL K 3 K 1 K 2R E N A U C O N T R O LA I R L O O K I N G A T R E A Rt °t °M E A T P R O B EA I R P R OB ES O L I D S T A T E R E L A YA I R H E A T E RL 1 T 1A 2(-) A 1(+)H I G H L I M I TV E N T F A NV E N T F A N H I G H T E M P c l o s e s @130FT E R M I N A L B L O C KT E R M I N A L B L O C KT E R M I N A L B L O C KT R I A D12 V A C W H I T EB L AC KB L U EB R O W NG R A YY E L L O WP U R P L ER E D208/240 V A CH A M M O N D12V A CW H I T EB L AC KB R O W NO R A N G ER E DY E L L O W B L U EG R A Y208/240 V A C16151413121110987654321G R O U N D *。

Televac MP7ER FR 双反磁性磁管冷电子仪器产品说明书

Televac MP7ER FR 双反磁性磁管冷电子仪器产品说明书

INSTRUCTION MANUALMP7ER/FR RemoteDouble Inverted Magnetron Cold Cathode GaugeRange: 7ER 10-8 to 10-2 Torr7FR 10-11 to 10-2 TorrTELEVACA DIVISION OF THE FREDERICKS COMPANY2400 PHILMONT AVE.HUNTINGDON VALLEY, PA 19006PARTS LISTDescription and Instrument OperationThe MP7ER/FR series Remote Module provides a compact stand-alone measurement solution for applications that do not require traditional panel-mounted instrument readouts. These modules can provide local readout and control or can be interfaced directly with a PLC, chart recorder, or data acquisition system. The MP7ER/FR series of instruments use the time proven reliable and rugged TELEVAC 7ER/FR Sensor, which can be changed in seconds. These instruments operate from low voltage DC and are easily integrated into the largest process system with a minimal effort. Likewise, the MP7ER/FR Remote Gauge can be used as a small stand-alone vacuum measurement solution.Features» Wide range 10-2 to 10-11 Torr» Fast restart at high vacuum» No x-ray limit» Reduced external magnetic field» Compact design» Rugged/durable» No-filament burnout»No degassing required» Long life» Cleanable sensor (7ER)START BY READING THESE IMPORTANT SAFETY INSTRUCTIONS AND NOTES collected herefor your convenience and repeated with additional information at appropriate points in these instructionsIn these instructions the word “product” refers to the MP7ER/FR and all of its approved parts and accessories.NOTE: These instructions do not and cannot provide for every contingency that may arise inconnection with the installation, operation, or maintenance of this product. Should you requirefurther assistance; please contact Televac at the address on the title page of this manual.This product has been designed and tested to offer reason ably safe service provided in it’s installed, operated and serviced in strict accordance with these safety instructions.These safety precautions must be observed during all phases of operation, installation, and service of this product. Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design, manufacture, and intended use of the instrument. Televac disclaims all liability for the customer’s failure to comply with these requir ements.√READ Instructions– Read all safety and operating instructions before operating the product.√RETAIN instructions– Retain the Safety and Operating Instructions for future reference.√ HEED warnings– Adhere to all warnings on the product and in the operating instructions.√FOLLOW instructions–Follow all operating and maintenance instructions.√ACCESORIES– Do not use accessories not recommended in this manual as they may requirea technician to restore the product to its normal operation.CHAPTER 3Principles of Sensor OperationDouble Inverted MagnetronCold Cathode GaugeThe cold cathode gauge is a high vacuum sensor that measures pressure by ionizing the residual gases in a magnetron discharge. The body of the gauge serves as a cathode, and is at ground potential. The anode operates at voltages up to 4000 volts. The permanent magnet traps electrons in the gauge to sustain the discharge at very low pressure. This gauge is sensitive to gas type. Because of the relative ruggedness of this gauge and since it has no filament to burn out, it is often used in applications where hot cathode gauges are not reliable.SENSOR OPERATION AND INSTALLATION1.0 Connect the gauge to the vacuum system, (can be connected in any position, but mounting withthe vacuum port facing down eliminates any chance of particles entering into the gauge).2.0 Assure that there are no leaks.3.0 Apply 24 DC volt power between pin #4 (+) and #2 (-). Monitor the signal output with a digital voltmeter between pin # 3 (+) and pin # 7. The display will show “OFF” and the signal output will be between 10.5 volts and 14.5 volts.4.0 The gauge is activated by grounding the wire from pin # 1 of the connector and may be operatedover any vacuum range, however, the following cautions.4.1 Activate the gauge only at pressures below 10-2 Torr. Continuous operation above thisrange will result in build up of contaminants inside the gauge and will produce errors inreading. In addition, at even higher pressures the gauge may falsely indicate lowerpressures by having passed beyond the peak of its curve.4.2 Initial activation of the gauge at pressures below 10-6 Torr may exhibit a delay inproviding an accurate reading of pressure until the electrical discharge within the tubehas established itself. This initial delay increases significantly at even lower pressures.Once established the discharge within the tube is maintained over the entire range. Avery rough estimate of start time can be calculated as T, sec = 1/pressure in µTorr.5.0 While the pressure is above the range of the gauge it will display “HI” and the signal output will bejust above the highest reading. If, on the other hand the pressure is below the lower gauge limit, the display will display “LO” and the signal output will remain at its lowest value.6.0 The trip pressure for the setpoint relay can be displayed by pressing the “Display Setpoint”button. It can also be read as a voltage – anytime – on the wire pin # 9 of the connector. Thedisplay will show the setpoint pressure as a blinking number (to distinguish it from a pressurereading) until the button is again pressed or it times out automatically after 60 seconds. Thesetpoint pressure can be changed only during the blinking display by means of the labeledadjustment screw. The new value is retained in memory and the corresponding new voltage isprovided at the setpoint terminal on the connector and is scaled in the same way as the signaloutput.SENSOR OPERATION AND INSTALLATION (cont.)M P 7F R lo g 10-110123456789101.00E -111.00E -101.00E -091.00E -081.00E -071.00E -061.00E -051.00E -041.00E -031.00E -02P R E S S U R E (T O R R )V O L T A G ERecorder Outputs“HI”9.210.2Maintenance1.0 1.1 1.2 1.3 1.42.02.2 2.3 2.4 Blast the2.5 After cleaning, blow out any residual glass beads or dust with dry air.2.6 Rinse with alcohol, followed with a rinse of de-ionized water. 2.7 Dry anode assembly and the body in a clean oven @ ~ 200° F.2.8 Re-grease the “O” ring with Apiezon L or M Grease. (A vacuum approved grease).DO NOT APPLY EXCESS GREASE. “O” ring should be shiny. 2.9 Install “O” ring in body..2.10 Replace the anode assembly in the body after the “O” ring has been installed.2.11 Screw the cap on and hand tighten.CHAPTER 6TELEVACCHAPTER 8CHAPTER 73.1 Without removing the sensor from the vacuum system, separate the electronic block from the sensor as described in Section 1.0 (Disassembling the 7ER/7FR ).3.2 After separating the electronics from the sensor, but before disassembling of the sensor for cleaning, use a marker to mark the orientation and positions of the magnets relative to each other and relative to the stainless steel sensor tube. These are aligned at the factory for optimum performance of the sensor. When reassembling after cleaning, reassemble I reverse order with the magnets in their original respective locations and like pole surfaces facing each other (N to N, S to S).3.3 Holding the magnets, use a 1/32” Allen wrench to remove three setscrews on the top alumin um holding ring.3.4 Slide away the magnet’s washers and aluminum spacers from the tube’s body. Do not remove the lower aluminum holding ring (one that is closest to the flange).3.5 Bake out the sensor using heat tape, blanket or other means with temperature controls. Temperature on the gauge’s surface should not exceed 350°C. NOTE : if the bake out temperature does not exceed 180°C for 2 hours, the sensor could be baked out with the magnets in place.3.6 After cooling the sensor down to room temperature, re-assemble with the magnets in their original respective locations and like pole surfaces facing each other (N to N, S to S).3.7 Put the electronic block onto the sensor and secure it with flat socket screw.CalibrationAll instrumentation is calibrated at the factory. No further calibration at the customer’s facility should be required, even if the gauge tube is replaced.For a reliable recalibration at a later date, it is necessary to have a reference standard vacuum system whose pressure is known to be accurate. For such a calibration, the instrument and sensor tube should be returned to the factory for re-certification. However, if the vacuum calibration verification must be done at the custo mer’s facility, a knowledgeable electronics technician trained in vacuum calibration should operate equipment of certifiable accuracy.Troubleshooting1.0 If display consistently displays “HI”, the pressure may be above the gauge upper limit (1 x 10-2 TORR) units to the gauge or there may be a leak locally. Check the integrity of the vacuum connection and, if the 7E sensor is used, check the o-ring seal on the sensor tube.2.0 If the display constantly reads “LO”, the sensor may ha ve become inoperative. Check for correct reassembly after bake out.3.0 If the display continues to read “LO” or “HI” after completing step 1.0 or 2.0, the sensor may be contaminated. Contamination can prevent the sensor from properly discharging (reference chapter 4, paragraph4.0 of this manual for information on operation of the sensor). To clean the sensor, refer to chapter 6, paragraph 2.0 of this manual.NOTE: If, after doing some or all of the above, the unit is still inoperative, return to the factory for repair.SpecificationsMeasurement Range RangeOutput Options1. Log 10 -10 to 10-2 Torr MP7ER: 10-2 TO 10-8 TORR2. Linear 10-8 to 10-3 Torr MP7FR 10-2 TO 10-11 TORR3. Log 2 X 10-11 to 10-2 TorrAccuracy Mounting Orientation+/-0.2 of decade of reading NoneInput Voltage/Power Ion ControlRequired +24 V DC @ 250 mA Ion ON/OFF Control is included Power ON Indicator LED is includedSetpoint Relay Adjustment PotentiometerForm C Contact SetpointOperating Temperature Calibration Medium+ 15 to 50C Dry Air or NitrogenSensor Material Overpressure ToleranceStainless Steel (Type 304) 150 PSIUnpacking and InspectionBefore each unit is installed or operated, a quick inspection should be performed and the following noted:a. damage to the unit (scratches, nicks, dents, cracks, etc.)b. missing: screws, switches or switch hardwarec. broken barrier strips, etc.d. broken or loose components within instrumentShould any of the above problems be encountered, contact the factory immediately. Any unauthorized repairs will void the warranty.CHAPTER 12Warranty informationThe Televac division warrants instruments and components to be free of defects in material and workmanship for a period of one year after the date of shipment unless otherwise specified in the quotation pr product literature. No salesman, Representative or agent of the Fredericks Company, or its divisions is authorized to give any guarantee or warranty or make any representation in addition or contrary to those stated herein.Other than those expressly stated herein, there are no other warranties of any kind, express or implied and specially excluded but not by way of limitation, are the implied warranties of fitness for a particular purpose and merchantability. It is understood and agreed the seller’s liability whether in contract, in tort, under any warranty, in negligence or otherwise shall not exceed the return of the amount of the purchase price paid by the purchases and under no circumstances shall seller be liable for special, indirect, incidental or consequential damages. The price stated for the equipment is a consideration in limiting seller’s liability. No action regardless of form, arising out of transactions of this agreement may be brought by purchase more than one year after the ca use of action has accrued, seller’s maximum liability shall not exceed and buyer’s remedy is limited to either (1) repair or replacement.。

Extech 品牌 0.12英寸双射线热传感器说明书

Extech 品牌 0.12英寸双射线热传感器说明书

Ordering42509.......................12"Distance Dual Laser InfraRed Thermometer 42509-NIST .............42509with NIST Certificate42509IR Thermometer with Color AlertProgrammable alarm with fast two-color display and audible alarm42512Dual Laser IR ThermometerFast and accurate measurements to 1832°F (1000°C)Features:•Great for processes that require temperature control and monitoring•Fast,accurate measurements at 12"where the two lasers converge with 12:1field of view •Measures up to 950°F (510°C)•Blue backlit dual LCD display changes to Red when reading exceeds High or Low set points•Exclusive 150millisecond instantaneous response for capturing spikes in temperature •Max mode captures and holds rapidly changing temperatures•Lock function for continuous readings •Adjustable emissivity increases measurement accuracy for different surfaces•Adjustable High/Low set points with audible alarm alerts user when temperature exceeds the programmed set points •Double molded housing•Complete with case and 9V batteryFeatures:•Dual laser simplifies distance-to-target ratio—no more calculations!•Accurate measurements at 30"distance •Exclusive 150millisecond instantaneous response for capturing spikes in temperature •Max mode captures andholds rapidly changing temperatures•Lock functionfor continuous readings •White backlit dual LCD display•Adjustable emissivity increases measurement accuracy for different surfaces •Double molded housing•Adjustable High/Low set points with audible alarm alerts user when temperature exceeds the programmed set points•Complete with carrying case and 9V battery30"Distance IRFastresponse captureshot spotsuseConvergence point 1"(2.54cm)spot30"(76.2c m)Ordering42512.......................30"Distance Dual Laser InfraRed Thermometer 42512-NIST .............42512with NIST CertificateBlue backlight:42570High Temperature IR Thermometer Fast response(100mS)with highest accuracy at point wheredual lasers converge plus Type K input and USB interfaceFeatures:•High50:1distance to target ratio measures smaller surface areas at greater distances•Dual Laser Targeting indicates ideal measuring distance when two laser points converge to1" target spot•Fast0.10second response time •Lock function for continuous measurements•Stores up to100readings •White backlit LCD with bargraph •MAX/MIN/AVG/DIF functions •Adjustable emissivity •Adjustable High/Low set points with audible alarm •T ripod mounting feature •Complete with Type K bead wire probe(-22to572°F/ -30to300°C),USB cable and PC software,tripod,9V battery and case(See pages42and80for Type K Thermocouple probes)Type K input42560IR Thermometer with Wireless PC InterfaceWireless USB interface transmits temperature data to a PCFeatures:•Place meter on the Base totransmit wirelessly continuousreadings to the Remote Receiverconnected to a PC via USB cable•High30:1distance to target ratio•Built-in laser pointer•Lock function for continuousmeasurements•Stores up to20readings•Type K temperature function•MAX/MIN/AVG/DIF functions•Manual/Automatic emissivity•High/Low set points withaudible alarms•Data Hold,Auto power off withdisable function,low batteryindication,1mV/°F analog output•T ripod mounting feature•Complete with T ransmitter Base,Remote Receiver with USB cable,Type K bead wire probe(-22to572°F/-30to300°C),tripod,analog output cable,PC software,9V battery,AC adaptor,andhard caseSee p.80for additional Type KThermocouple probes(sold separately)Ordering42570...................50"Distance Dual Laser InfraRed Thermometer42570-NISTL*....42570with NIST Certificate*Limited NIST for Certificate of Traceability from-4to1500°F(-20to815°C).Type K inputOrdering42560...............IR Thermometer w/Wireless PC Interface(918MHz)42560-NIST.....42560with NIST Certificate42560-E...........IR Thermometer w/Wireless PC Interface(433MHz)42560-E-NIST.42560-E with NIST CertificateTR100..............Spare T ripod(NOTE:USA,Mexico,and Canada use918MHz model and majority of other countries use433MHz model)InfraRed ThermometersExtech’s range of High Temperature IR Thermometers include models with alarms,Type K inputs or Datalogging and printing capabilities.Type K input for contact measurementsHigh50:1 Field of ViewIR1001:1,ThermometerMini convenience •Measures temperature •Economical for InfraRed ThermometersExtech’s non-contact InfraRed thermometers point and measuretechnology provide fast,easy and accurate readings for most surface temperature measurements.Mini sizePalm size Compact Handheld size Compact Handheld。

Henkel Ireland Limited 99C 362 5C 产品说明书

Henkel Ireland Limited 99C 362 5C 产品说明书

Safety Data Sheet according to (EC) No 1907/2006Page 1 of 8sds no. : 221815V004.0 99C 362 5CRevision: 14.05.2012printing date: 23.07.2012SECTION 1: Identification of the substance/mixture and of the company/undertaking1.1. Product identifier99C 362 5C1.2. Relevant identified uses of the substance or mixture and uses advised againstIntended use:Solder Wire1.3. Details of the supplier of the safety data sheetHenkel Ireland LimitedProduct Safety & Regulatory AffairsTallaght Business Park, WhitestownDublin 24IrelandPhone: +353 (14046444)Fax-no.: +353 (14519926)*****************************.com1.4. Emergency telephone number24 Hours Emergency Tel: +44 (0)1442 278497SECTION 2: Hazards identification2.1. Classification of the substance or mixtureClassification (DPD):SensitizingR43 May cause sensitisation by skin contact.2.2. Label elementsLabel elements (DPD):Xi - IrritantRisk phrases:R43 May cause sensitisation by skin contact.Safety phrases:S24 Avoid contact with skin.S37 Wear suitable gloves.S23 Do not breathe fumes.Contains:Rosin2.3. Other hazardsFlux fumes emitted during reflow will irritate the nose and throat and may cause an asthmatic type reaction.Regulations forbid the use of lead solder in any private or public drinking water supply system.SECTION 3: Composition/information on ingredients Declaration of the ingredients according to CLP (EC) No 1272/2008:Hazardous componentsCAS-No.EC NumberREACH-Reg No.content ClassificationTin 7440-31-5231-141-801-2119486474-28>= 90- < 100%Copper Metal7440-50-8231-159-6 >= 0,1- < 1%Rosin 8050-09-7 232-475-7 >= 1- < 5% Skinsensitizer1H317For full text of the H - statements and other abbreviations see section 16 "Other information". Substances without classification may have community workplace exposure limits available. Declaration of ingredients according to DPD (EC) No 1999/45:Hazardous componentsCAS-No.EC NumberREACH-Reg No.content ClassificationTin 7440-31-5231-141-801-2119486474-28>= 90 - < 100 %Copper Metal7440-50-8231-159-6 >= 0,1 - < 1 %Rosin 8050-09-7 232-475-7 >= 1 - < 5 %R43For full text of the R-Phrases indicated by codes see section 16 'Other Information'. Substances without classification may have community workplace exposure limits available.SECTION 4: First aid measures4.1. Description of first aid measuresInhalation:Move to fresh air. If symptoms persist, seek medical advice.Skin contact:Rinse with running water and soap.Obtain medical attention if irritation persists.Eye contact:Flush eyes with plenty of water for at least 5 minutes. If irritation persists seek medical attention.Ingestion:Do not induce vomiting.Seek medical advice.4.2. Most important symptoms and effects, both acute and delayedFlux fumes may irritate the nose, throat and lungs and may after prolonged/repeated exposure give an allergic reaction (asthma).SKIN: Rash, Urticaria.4.3. Indication of any immediate medical attention and special treatment neededSee section: Description of first aid measuresSECTION 5: Firefighting measures5.1. Extinguishing mediaSuitable extinguishing media:Carbon dioxide, foam, powderFine water sprayExtinguishing media which must not be used for safety reasons:Do not use water on fires where molten metal is present.5.2. Special hazards arising from the substance or mixtureHigh temperatures may produce heavy metal dust, fumes or vapours.The flux medium will give rise to irritating fumes.5.3. Advice for firefightersWear self-contained breathing apparatus.SECTION 6: Accidental release measures6.1. Personal precautions, protective equipment and emergency proceduresWear protective equipment.6.2. Environmental precautionsDo not empty into drains / surface water / ground water.6.3. Methods and material for containment and cleaning upScrape up spilled material and place in a closed container for disposal.6.4. Reference to other sectionsSee advice in chapter 8SECTION 7: Handling and storage7.1. Precautions for safe handlingExtraction is necessary to remove fumes evolved during reflow.When using do not eat, drink or smoke.Wash hands before breaks and immediately after handling the product.Avoid breathing fumes given out during soldering.See advice in chapter 8Hygiene measures:Good industrial hygiene practices should be observed.Do not eat, drink or smoke while working.After handling solder wash hands with soap and water before eating, drinking or smoking.7.2. Conditions for safe storage, including any incompatibilitiesEnsure good ventilation/extraction.Store in a cool, dry place.7.3. Specific end use(s)Solder WireSECTION 8: Exposure controls/personal protection8.1. Control parametersValid forGreat BritainIngredient ppm mg/m3Type Category RemarksTIN (INORGANIC COMPOUNDS AS SN) 7440-31-5 2 Time Weighted Average(TWA):Indicative ECTLVROSIN-BASED SOLDER FLUX FUME 8050-09-7 0,05 Time Weighted Average(TWA):EH40 WELROSIN-BASED SOLDER FLUX FUME 8050-09-7 0,15 Short Term ExposureLimit (STEL):EH40 WELColophony (Rosin) and derivatives: Rosin-based flux fume as total resin acids.8.2. Exposure controls:Engineering controls:Extraction is necessary to remove fumes evolved during reflow.Where reasonably practicable this should be achieved by the use of local exhaust ventilation and good general extraction.Ensure good ventilation/extraction.Respiratory protection:Ensure adequate ventilation.An approved mask or respirator fitted with an organic vapour cartridge should be worn if the product is used in a poorly ventilated areaIn case of aerosol formation, we recommend wearing of appropriate respiratory protection equipment with ABEK P2 filter.This recommendation should be matched to local conditions.Hand protection:Please note that in practice the working life of chemical resistant gloves may be considerably reduced as a result of many influencing factors (e.g. temperature). Suitable risk assessment should be carried out by the end user. If signs of wear and tear are noticed then the gloves should be replaced.The use of chemical resistant gloves such as Nitrile are recommended.Eye protection:Safety glasses with sideshields or chemical safety goggles should be worn if there is a risk of splashing.Skin protection:Wear suitable protective clothing.SECTION 9: Physical and chemical properties9.1. Information on basic physical and chemical propertiesAppearance solidgreyOdor NoneapplicablepH notInitial boiling point No data available / Not applicableFlash point NoneDecomposition temperature No data available / Not applicableVapour pressure not applicable7,3 g/cm3Density(25 °C (77 °F))Bulk density No data available / Not applicableViscosity No data available / Not applicableViscosity (kinematic) No data available / Not applicableExplosive properties No data available / Not applicableInsolubleSolubility (qualitative)(Solvent: Water)Solidification temperature No data available / Not applicableMelting point227 °C (440.6 °F)Flammability No data available / Not applicableAuto-ignition temperature No data available / Not applicableExplosive limits No data available / Not applicablePartition coefficient: n-octanol/water Not applicableEvaporation rate No data available / Not applicableVapor density No data available / Not applicableOxidising properties No data available / Not applicable9.2. Other informationNo data available / Not applicableSECTION 10: Stability and reactivity10.1. ReactivitySolder alloy will react with concentrated nitric acid to produce toxic fumes of nitrogen oxides.10.2. Chemical stabilityStable under recommended storage conditions.10.3. Possibility of hazardous reactionsSee section reactivity10.4. Conditions to avoidNo decomposition if stored and applied as directed.10.5. Incompatible materialsNone if used properly.10.6. Hazardous decomposition productsThermal decomposition can lead to release of irritating gases and vapors.SECTION 11: Toxicological information11.1. Information on toxicological effectsGeneral toxicological information:The preparation is classified based on the conventional method outlined in Article 6(1)(a) of Directive 1999/45/EC. Relevant available health/ecological information for the substances listed under Section 3 is provided in the following.Oral toxicity:This material is considered to have low toxicity if swallowed.Inhalative toxicity:Fumes evolved at soldering temperatures will irritate the nose, throat and lungs. Prolonged or repeated exposure to flux fumes may result in sensitisation in sensitive workers.Dermal toxicity:This product is considered to have low dermal toxicity.Skin irritation:Fumes emitted during soldering may irritate the skin.Eye irritation:Fumes emitted during soldering may irritate the eyes.Sensitizing:May cause sensitization by skin contact.Skin corrosion/irritation:Hazardous components CAS-No. Result ExposuretimeSpecies MethodCopper Metal7440-50-8irritating Serious eye damage/irritation:Hazardous components CAS-No. Result ExposuretimeSpecies MethodCopper Metal7440-50-8irritatingSECTION 12: Ecological informationGeneral ecological information:Do not empty into drains / surface water / ground water.The preparation is classified based on the conventional method outlined in Article 6(1)(a) of Directive 1999/45/EC. Relevant available health/ecological information for the substances listed under Section 3 is provided in the following.Ecotoxicity:May cause long-term adverse effects in the aquatic environment.Mobility:The product is insoluble and sinks in water.Persistence and Biodegradability:The product is not biodegradable.Bioaccumulative potential:Octanol/Water distribution coefficient: Not applicable12.1. ToxicityHazardous componentsCAS-No. ValuetypeValue AcuteToxicityStudyExposuretimeSpecies MethodCopper Metal 7440-50-8 LC50> 10 mg/l Fish96 h Lepomis macrochirus OECD Guideline203 (Fish, AcuteToxicity Test)Rosin 8050-09-7 LC50> 1.000 mg/l Fish96 h Pimephales promelas OECD Guideline203 (Fish, AcuteToxicity Test)Rosin 8050-09-7 EC50911 mg/l Daphnia48 h Daphnia magna OECD Guideline202 (Daphnia sp.AcuteImmobilisationTest)Rosin 8050-09-7 EC50> 100 mg/l Algae72 h Scenedesmus subspicatus (newname: Desmodesmussubspicatus)12.2. Persistence and degradabilityHazardous componentsCAS-No. Result RouteofapplicationDegradability MethodRosin 8050-09-7aerobic 36 - 46 % OECD Guideline 301 F (ReadyBiodegradability: ManometricRespirometry Test) SECTION 13: Disposal considerations13.1. Waste treatment methodsProduct disposal:Wherever possible unwanted solder alloy should be recycled for recovery of metal.Otherwise dispose of in accordance with local and national regulations.Disposal of uncleaned packages:Dispose of as unused product.Waste code06 04 05 - wastes containing other heavy metalsSECTION 14: Transport informationGeneral information:Not hazardous according to RID, ADR, ADNR, IMDG, IATA-DGR.SECTION 15: Regulatory information15.1. Safety, health and environmental regulations/legislation specific for the substance or mixtureVOC content< 5,0 %National regulations/information (Great Britain):Remarks The Health & Safety at Work Act 1974.The Control of Substances Hazardous to Health Regulations. L5:GeneralApproved Code of Practice to the COSHH Regulations. HS(G)97:A Step by StepGuide to the COSHH Regulations. HS(G)193:COSHH essentials: Easy steps tocontrol chemicals.IND (G)248L:Solder fume and you. IND(G)249L:Controlling health risks fromrosin (colophony) based solder fluxes.SECTION 16: Other informationThe labelling of the product is indicated in Section 2. The full textof all abbreviations indicated by codes in this safety data sheet are as follows:R43 May cause sensitisation by skin contact.H317 May cause an allergic skin reaction.Further information:This information is based on our current level of knowledge and relates to the product in the state in which it is delivered. It is intended to describe our products from the point of view of safety requirements and is not intended to guarantee anyparticular properties.This safety data sheet was prepared in accordance with Council Directive 67/548/EEC and it's subsequent amendments, and Commission Directive 1999/45/EC.。

相关主题
  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
相关文档
最新文档