H3C S9500交换机MPLS VPN和NAT共用的配置一、组网需求:如下组网中,出端口G0/1/3下启用两个VLAN 端口,vlan 2专门跑NAT 业务,vlan 3则运行MPLS VPN业务,vlan 20 和vlan30 分别是下接的两种业务的用户。
二、组网图三、配置步骤软件版本:H3C S9500交换机全系列软件版本硬件版本:H3C S9500交换机CA类板和NAT业务板1)在SR88与S9500之间建两个vlan,并在95 g0/3/1和对端88g2/1/4口上trunck [S9500] interface GigabitEthernet0/3/1[S9500-GigabitEthernet0/3/1] port link-type trunk[S9500-GigabitEthernet0/3/1] port trunk permit vlan 1 to 3[SR88]interface GigabitEthernet2/1/4[SR88-GigabitEthernet2/1/4] port link-type trunk[SR88-GigabitEthernet2/1/4] port trunk permit vlan 1 to 32)S9500 vlan2上绑定NAT业务[S9500] nat address-group 0 10.33.254.5 10.33.254.6[[S9500]acl number 3001[[S9500-acl-adv-3001]rule 0 permit ip source 192.168.30.0 0.0.0.255[S9500]interface Vlan-interface 2[S9500-Vlan-interface2] ip address 10.33.254.1 255.255.255.0[S9500-Vlan-interface2]nat outbound 3001 address-group 0 slot 3#3号槽为NAT板#3)S9500 vlan3上绑定MPLS VPN业务[S9500]interface Vlan-interface 3[S9500-Vlan-interface3]ip address 10.33.252.1 255.255.255.0[S9500-Vlan-interface3]ospf cost 100#防止形成等价路由#[S9500-Vlan-interface3]mpls[S9500-Vlan-interface3]mpls ldp enable[S9500-Vlan-interface3]mpls ldp transport-ip interface4)在SR88和9500上都配置静态路由指定mpls出口[S9500]ip route-static 2.2.2.2 255.255.255.255 10.33.252.2 preference 60 [SR8800]ip route-static 1.1.1.1 255.255.255.255 10.33.252.1 preference 60#指定私网路由从vlan 3端口出去#四、配置关键点:1)配置端口下的ospf cost值,防止在88和9500间形成等价路由;2)通过静态路由指定私网路由从vlan端口走,并且通过在端口下配置mpls ldp transport-ip interface 使得ldp也从vlan 3端口学习;3)本配置主要考虑了MPLS VPN和NAT合用的一些关键配置,关于MPLS VPN 和NAT的一般配置未详细列出;。
H3C S9500ES12500系列交换机上ACGIPS插卡MQC引流典型配置
H3C S9500E&S12500系列交换机上ACG&IPS插卡MQC引流典型配置一、组网需求:某客户购买了两块SecBlade IPS插卡部署在S95E交换机上,为内网提供攻击检测和安全防护,两台交换机运行在IRF模式,外网用户访问服务器的流量经过IPS插卡,内部服务器互访的流量不上IPS插卡,并且两块插卡能实现主备,当其中一块插卡故障以后业务可以迅速切换到另一块插卡。
二、组网图:如上图所示:两台S9505E交换机堆叠,每台交换机上插一块IPS插卡,内部服务器网关部署在交换机上,服务器互访的流量不经过IPS插卡,外部用户防范服务器的流量正常情况下经过IPS-1,当IPS-1故障以后,流量经过IPS-2。
交换机版本:Comware Software, Version 5.20, Release 1238P08IPS插卡版本:i-Ware software, Version 1.10, Ess 2110P10三、配置步骤:交换机上关键配置:#acsei server enable //通过acsei协议对插卡进行时间同步和状态检测,实现主备切换#acl number 3001 //匹配上插卡的流量description Match-ALL-Addressrule 0 permit ipacl number 3002 //匹配上插卡的流量,用于备份description Match-ALL-Addressrule 0 permit ipacl number 3004 //内网互访的流量不上插卡description Match-Internal-Flowrule 0 permit ip destination 192.168.14.0 0.0.0.255rule 5 permit ip destination 192.168.15.0 0.0.0.255rule 10 permit ip destination 192.168.16.0 0.0.0.255rule 15 permit ip destination 192.168.17.0 0.0.0.255rule 20 permit ip destination 192.168.18.0 0.0.0.255#acl number 4000 //匹配广播、组播和ARP报文description Match-Multicast-Broadcast-ARPrule 0 permit dest-mac 0100-0000-0000 ff00-0000-0000rule 5 permit dest-mac ffff-ffff-ffff ffff-ffff-ffffrule 10 permit type 0806 ffff#vlan 1001 to 1008#vlan 4000 //用于IRF的BFD MAD检测description Mad-Detection#traffic classifier Internal-Flow-1 operator andif-match acl 3004traffic classifier Multicast-Broadcast-ARP operator andif-match acl 4000traffic classifier All-Address-1 operator andif-match acl 3001if-match forwarding-layer route //仅将三层转发流量引流traffic classifier All-Address-2 operator andif-match acl 3002if-match forwarding-layer route#traffic behavior Deny-Multicast-Broadcast-ARPfilter denytraffic behavior Redirect-To-IPS-1redirect interface Ten-GigabitEthernet1/4/0/1traffic behavior Redirect-To-IPS-2redirect interface Ten-GigabitEthernet2/4/0/1traffic behavior Allowfilter permit#qos policy Deny-Multicast-Broadcast-ARP //本地产生的组播、广播和ARP报文不上插卡classifier Multicast-Broadcast-ARP behavior Deny-Multicast-Broadcast-ARPqos policy DOWN_STREAMclassifier Multicast-Broadcast-ARP behavior Allow //广播等报文不上插卡classifier All-Address-1 behavior Redirect-To-IPS-1 //流量先上IPS-1classifier All-Address-2 behavior Redirect-To-IPS-2 //IPS-1故障后上IPS-2qos policy UP_STREAMclassifier Multicast-Broadcast-ARP behavior Allowclassifier Internal-Flow-1 behavior Allow //内网互访流量不上插卡classifier All-Address-1 behavior Redirect-To-IPS-1classifier All-Address-2 behavior Redirect-To-IPS-2#interface Vlan-interface1001ip address 192.168.11.254 255.255.255.0#interface Vlan-interface1002ip address 192.168.12.254 255.255.255.0#interface Vlan-interface1004ip address 192.168.14.254 255.255.255.0#interface Vlan-interface1005ip address 192.168.15.254 255.255.255.0#interface Vlan-interface1006ip address 192.168.16.254 255.255.255.0#interface Vlan-interface1007ip address 192.168.17.254 255.255.255.0#interface Vlan-interface1008ip address 192.168.18.254 255.255.255.0#interface Vlan-interface4000 //BFD MAD检测VLANmad bfd enablemad ip address 200.0.0.1 255.255.255.252 chassis 1mad ip address 200.0.0.2 255.255.255.252 chassis 2#interface GigabitEthernet1/2/0/17 //专用于MAD检测的端口,关闭STPport access vlan 4000stp disable#interface GigabitEthernet2/2/0/17port access vlan 4000stp disable#接口上下发MQC:#interface GigabitEthernet1/2/0/1port access vlan 1004qos apply policy UP_STREAM inbound#interface GigabitEthernet1/2/0/2port access vlan 1001qos apply policy DOWN_STREAM inbound#interface GigabitEthernet2/2/0/1port access vlan 1008qos apply policy UP_STREAM inbound#interface GigabitEthernet2/2/0/2port access vlan 1002qos apply policy DOWN_STREAM inbound#S95E与IPS插卡接口配置:#interface Ten-GigabitEthernet1/4/0/1port link-type trunkport trunk permit vlan 1 1001 to 1008 //必须允许VLAN 1通过,否则跨框重定向报文不生效stp disableqos apply policy Deny-Multicast-Broadcast-ARP inbound //防止本地产生的组播、广播、ARP报文从内敛口转发到插卡,S95E&S12500对于本机发出的协议报文,用MQC在outbound方向不能过滤,会导致环路,ospf邻居down等问题,所以需要在inbound方向过滤mac-address max-mac-count 0#interface Ten-GigabitEthernet2/4/0/1port link-type trunkport trunk permit vlan 1 1001 to 1008stp disableqos apply policy Deny-Multicast-Broadcast-ARP inboundmac-address max-mac-count 0#acsei server //配置acsei时间参数,一般保持默认即可acsei timer clock-sync 1 //配置插卡同步时间的间隔,单位分钟,默认5分钟acsei timer monitor 1 //配置对插卡的监控时间间隔,单位是秒,默认5秒#irf-port 1/1port group interface GigabitEthernet1/2/0/15port group interface GigabitEthernet1/2/0/16#irf-port 2/2port group interface GigabitEthernet2/2/0/15port group interface GigabitEthernet2/2/0/16#IPS插卡相关配置(两快IPS插卡的配置一样):1.去使能OAA ACFP Client。
华三交换机端口安全操作
1-1
H3C S5500-EI 系列以太网交换机 操作手册 端口安全
第 1 章 端口安全配置
1.1.3 端口安全模式
对于端口安全模式的具体描述,请参见 表 1-1。
i
H3C S5500-EI 系列以太网交换机 操作手册 端口安全
第 1 章 端口安全配置
ቤተ መጻሕፍቲ ባይዱ
第1章 端口安全配置
1.1 端口安全简介
1.1.1 概述
端口安全是一种基于 MAC 地址对网络接入进行控制的安全机制,是对已有的 802.1x 认证和 MAC 地址认证的扩充。这种机制通过检测数据帧中的源 MAC 地址来控制非 授权设备对网络的访问,通过检测数据帧中的目的 MAC 地址来控制对非授权设备 的访问。 端口安全的主要功能是通过定义各种端口安全模式,让设备学习到合法的源 MAC 地址,以达到相应的网络管理效果。启动了端口安全功能之后,当发现非法报文时, 系统将触发相应特性,并按照预先指定的方式进行处理,既方便用户的管理又提高 了系统的安全性。 非法报文包括: z 禁止 MAC 地址学习时,收到的源 MAC 地址为未知 MAC 的报文; z 端口学习到的 MAC 地址达到端口所允许的最大 MAC 地址数后,收到的源
H3C S5500-EI 系列以太网交换机 操作手册 端口安全
目录
目录
第 1 章 端口安全配置 ..............................................................................................................1-1 1.1 端口安全简介 ..................................................................................................................... 1-1 1.1.1 概述 ......................................................................................................................... 1-1 1.1.2 端口安全的特性 ....................................................................................................... 1-1 1.1.3 端口安全模式........................................................................................................... 1-2 1.2 端口安全配置任务简介....................................................................................................... 1-4 1.3 使能端口安全功能 .............................................................................................................. 1-4 1.3.1 配置准备 .................................................................................................................. 1-4 1.3.2 使能端口安全功能.................................................................................................... 1-4 1.4 配置端口允许的最大安全MAC地址数 ................................................................................ 1-5 1.5 配置端口安全模式 .............................................................................................................. 1-6 1.5.1 配置autoLearn模式.................................................................................................. 1-6 1.5.2 配置userLoginWithOUI模式 .................................................................................... 1-7 1.5.3 配置其它模式........................................................................................................... 1-7 1.6 配置端口安全的特性 .......................................................................................................... 1-8 1.6.1 配置NeedToKnow特性 ............................................................................................ 1-8 1.6.2 配置入侵检测特性.................................................................................................... 1-8 1.6.3 配置Trap特性........................................................................................................... 1-9 1.7 配置安全MAC地址 ............................................................................................................. 1-9 1.7.1 配置准备 .................................................................................................................. 1-9 1.7.2 配置安全MAC地址................................................................................................. 1-10 1.8 配置当前端口不应用服务器下发的授权信息 .................................................................... 1-10 1.9 端口安全显示和维护 ........................................................................................................ 1-10 1.10 端口安全典型配置举例................................................................................................... 1-11 1.10.1 端口安全autoLearn模式配置举例 ........................................................................ 1-11 1.10.2 端口安全userLoginWithOUI模式配置举例........................................................... 1-13 1.10.3 端口安全macAddressElseUserLoginSecure模式配置举例 ................................. 1-18 1.11 常见配置错误举例 .......................................................................................................... 1-21 1.11.1 端口安全模式无法设置 ........................................................................................ 1-21 1.11.2 无法配置端口安全MAC地址 ................................................................................ 1-21 1.11.3 用户在线情况下无法更换端口安全模式............................................................... 1-22
H3C S5500-EI系列以太网交换机操作手册
H3C9500E系列交换机产品系统综述
4端口万兆以太网光接口业务板
2端口万兆以太网光接口业务板
16端口万兆以太网光接口业务板 20
S9500E单板介绍-48端口千兆板
LSRM1GP48LEF1 LSRM1GP48LEC1 LSRM1GP48LEB1 LSRM2GV48REB1 LSRM1GT48LEC1 LSRM2GT48LEB1
48端口千兆以太网光接口线速业务板(LC)
9
丰富的业务特性和良好的可扩展能力
支持分布式的MPLS/VPLS业务,提供高品质、安全和多层 次的MPLS VPN解决方案,支持MPLS/VPLS业务的全分布 式转发功能;
支持分布式的IPv6业务,适应网络业务不断发展的需求。 支持高性能组播、组播VPN等业务; 支持URPF,用来防止基于源地址欺骗的网络攻击行为; 基于OAA(Open Application Architecture)机制提供标
全球最全面的交换机产品线
数据中心路 由交换机
H3C S12518
H3C S12508 H3C S12504
核心路由 交换机
H3C S7500E
H3C S9500
H3C S9500E
全千兆智能 交换机
H3C S5100SI/EI H3C S5500SI/EI
H3C S5800系列
智能二层/三层 交换机
Engine
Crossbar
Crossbar
CPU FFDR EMS
智能化的EMS(Embedded Maintenance Subsystem-嵌入式维护子系统) CPU系统,支持 电源智能管理,设备状态检查。
Engine
Crossbar
Crossbar
CPU FFDR EMS
H3C S5120-EI系列以太网交换机 安装手册
H3C S5500-EI以太网交换机配置手册V101(国 内版)
H3C S5500-EI以太网交换机配置手册V101(国内版) 产品名称密级H3C S5500-EI以太网交换机(国内版) 机密产品版本共43页V200R001H3C S5500-EI以太网交换机配置手册V1.01(国内版)(仅供内部使用)日拟制: 王有为 2007-3-23期:日审核: 杨咸春 yyyy-mm-dd期:日审核: yyyy-mm-dd期:日批准: 沈明 yyyy-mm-dd期:华三通信技术有限公司版权所有侵权必究H3C S5500-EI以太网交换机配置手册(国内版) 机密修订记录日期修订版描述作者本2007-3-23 1.00 初稿完成王有为 2007-4-11 1.01 光模块集中加入1000BASE-T和BIDI光模块杨绵华2011-08-28 版权所有,侵权必究第2页,共43页H3C S5500-EI以太网交换机配置手册(国内版) 机密目录1 电信网络系统总体介绍(可选)..................................................................... .............. 9 2 产品基本配置说明...................................................................... .. (9)2.1 机柜布置图 ..................................................................... ..................................... 9 2.1.1 S5500-28C-EI ..................................................................... ................................ 9 2.1.2 S5500-28C-EI-DC ..................................................................... ........................ 10 2.1.3 S5500-52C-EI ..................................................................... .............................. 11 2.1.4 S5500-28C-PWR-EI ..................................................................... .................... 12 2.1.5 S5500-52C-PWR-EI ..................................................................... .................... 13 2.1.6 S5500-28F-EI(AC) ................................................................. ...................... 14 2.1.7 S5500-28F-EI(DC) ................................................................. ...................... 15 2.1.8 基本配置说明 ..................................................................... . (16)2.2 S5500-EI国内版产品配置清单及配置说明 ........................................................ 16 2.2.1 产品配置清单 ..................................................................... ............................... 16 2.2.2 配置说明 ..................................................................... (17)2.3 S5500-EI国内版调测整机配置说明 ...................................................................18 2.3.1 调测整机配置清单 ..................................................................... ........................ 18 2.3.2 调测整机配置说明 ..................................................................... (22)2.4 S5500-EI国内版总装机柜配置说明 ...................................................................23 2.4.1 总装机柜配置清单 ..................................................................... ........................ 23 2.4.2 总装机柜配置说明 ..................................................................... (26)2.5 S5500-EI功能模块配置说明 ..................................................................... ......... 26 2.5.1 1端口万兆以太网XFP光接口模块配置清单 ....................................................... 27 2.5.2 2端口万兆以太网XFP光接口模块配置清单 ....................................................... 27 2.5.3 2端口万兆以太网CX4接口模块配置清单 .......................................................... 27 2.5.4 CX4 本地连接线缆(clip-clip)-50cm模块配置清单 ............................................. 28 2.5.5 CX4 本地连接线缆(clip-clip)-100cm模块配置清单 ........................................... 28 2.5.6 CX4 本地连接线缆(clip-clip)-300cm模块配置清单 ........................................... 28 2.5.7 150W可插拔交流电源模块配置清单 (29)2.5.8 150W可插拔直流电源模块配置清单 (29)2.6 S5500-EI光电收发模块配置说明 ..................................................................... .. 292011-08-28 版权所有,侵权必究第3页,共43页H3C S5500-EI以太网交换机配置手册(国内版) 机密2.6.1 千兆多模光接口模块(850nm,0.55km)配置清单 ............................................. 30 2.6.2 千兆单模光接口模块(1310nm,10km)配置清单 ..............................................31 2.6.3 千兆单模光接口模块(1310nm,40km)配置清单 .............................................. 31 2.6.4 千兆单模光接口模块(1550nm,40km)配置清单 .............................................. 31 2.6.5 千兆单模光接口模块(1550nm,70km)配置清单 .............................................. 32 2.6.6 万兆XFP多模光接口模块(850nm ,300m)配置清单 ........................................32 2.6.7 万兆XFP单模光接口模块(1310nm ,10km)配置清单 ...................................... 32 2.6.8 万兆XFP单模光接口模块(1550nm,40km)配置清单 (33)2.6.9 百兆SFP光接口模块(1310nm,2km)配置清单 ................................................... 33 2.6.10 百兆SFP光接口模块(1310nm,15km)配置清单 ................................................. 33 2.6.11 百兆SFP光接口模块(1310nm,40km)配置清单 ................................................. 33 2.6.12 百兆SFP光接口模块(1550nm,80km)配置清单 ................................................. 34 2.6.13 千兆SFP电接口模块(100m,RJ45)配置清单 ...................................................... 34 2.6.14 千兆BIDI光模块(TX1310/RX1490,10km,LC)配置清单 ..................................... 34 2.6.15 千兆BIDI光模块(TX1490/RX1310,10km,LC)配置清单 (35)2.6.16 百兆BIDI光模块(TX1310/RX1550,15km,LC)配置清单 ..................................... 35 2.6.17 百兆BIDI光模块(TX1550/RX1310,15km,LC)配置清单 (35)2.6.18 接口配置说明 ..................................................................... ............................... 36 3 外部电源、电缆(光缆)配置说明 ..................................................................... .. (36)3.1 各种外部电源、电缆(光缆)的配置清单(国内版) ...................................... 36 4 发货附件配置说明...................................................................... (37)4.1 各种发货附件配置清单 ..................................................................... ................. 37 4.1.1 S5500-EI国内版发货附件配置清单 ................................................................... 37 5 安装成套件配置说明 ..................................................................... .............................. 38 6 配套设备配置说明...................................................................... ................................. 38 7 相关服务器的配置说明 ..................................................................... .......................... 38 8 终端系统配置说明...................................................................... (38)8.1 终端系统连接示意图 ..................................................................... .. (38)8.2 终端系统配置说明 ..................................................................... ........................ 39 8.2.1 终端设备配置清单 ..................................................................... ........................ 39 8.2.2 终端设备的配置说明 ..................................................................... .. (39)8.3 终端软件的选配说明 ..................................................................... .................... 40 9 网管系统配置说明...................................................................... (41)2011-08-28 版权所有,侵权必究第4页,共43页H3C S5500-EI以太网交换机配置手册(国内版) 机密9.1 网管系统连接示意图 ..................................................................... .. (41)9.2 网管系统的配置清单 ..................................................................... .. (41)9.3 网管系统配置说明 ..................................................................... ........................ 41 10 扩容和升级改造方法与配置说明...................................................................... .. (41)10.1 扩容方法与配置说明 ..................................................................... .. (41)10.2 升级改造方法与配置说明 ..................................................................... ............. 42 10.2.1 升级改造方法 ..................................................................... ............................... 42 10.2.2 升级设备的清单 ..................................................................... ............................ 42 10.2.3 可升级部分的说明 ..................................................................... ........................ 42 10.2.4 更换部件注意事项 ..................................................................... ........................ 42 11 其它配置说明 ..................................................................... .. (42)11.1 附录I:配置计算模板 ..................................................................... . (43)11.2 附录II:产品性能指标 ..................................................................... (43)11.3 附录III:缩略语清单 ..................................................................... (43)2011-08-28 版权所有,侵权必究第5页,共43页H3C S5500-EI以太网交换机配置手册(国内版) 机密表目录表1 H3C S5500-EI产品配置清单(国内版) .................................................................... .. 16 表2 0235A252调测整机的配置清单(国内版) ..................................................................18 表3 0235A24R调测整机的配置清单(国内版) ..................................................................19 表4 0235A24W调测整机的配置清单(国内版) (19)表5 0235A254调测整机的配置清单(国内版) ..................................................................20 表6 0235A24Y调测整机的配置清单(国内版) ..................................................................21 表7 0235A24T调测整机的配置清单(国内版) ..................................................................21 表8 0235A24V调测整机的配置清单(国内版) ..................................................................22 表9 0211A17X总装机柜配置清单 ..................................................................... ................... 23 表10 0211A18G总装机柜配置清单...................................................................... ................ 23 表11 0211A18A总装机柜配置清单 ..................................................................... ................. 24 表12 0211A17Y总装机柜配置清单 ..................................................................... ................. 24 表13 0211A18B总装机柜配置清单 ..................................................................... ................. 25 表14 0211A18N总装机柜配置清单 ..................................................................... ................. 25 表15 0211A18H总装机柜配置清单 ..................................................................... ................. 26 表16 1端口万兆以太网XFP光接口模块配置清单 (27)表17 2端口万兆以太网XFP光接口模块配置清单 (27)表18 2端口万兆以太网 CX4 接口模块配置清单 (27)表19 CX4 本地连接线缆(clip-clip)-50cm模块配置清单 ....................................................... 28 表20 CX4 本地连接线缆(clip-clip)-100cm模块配置清单 ..................................................... 28 表21 CX4 本地连接线缆(clip-clip)-300cm模块配置清单 ..................................................... 29 表22 150W可插拔交流电源模块配置清单 ..................................................................... ...... 29 表23 150W可插拔直流电源模块配置清单 ..................................................................... ...... 29 表24 S5500光电收发模块集配置清单 ..................................................................... ............ 30 表25 千兆多模光接口模块(850nm,0.55km)配置清单 ...................................................... 31 表26 千兆单模光接口模块(1310nm,10km)配置清单 ........................................................ 31 表27 千兆单模光接口模块(1310nm,40km)配置清单 ....................................................... 31 表28 千兆单模光接口模块(1550nm,40km)配置清单 ........................................................ 31 表29 千兆单模光接口模块(1550nm,70km)配置清单 ........................................................ 32 表30 万兆光接口模块(850nm ,300m)配置清单 (32)2011-08-28 版权所有,侵权必究第6页,共43页H3C S5500-EI以太网交换机配置手册(国内版) 机密表31 万兆光接口模块(1310nm ,10km)配置清单 .............................................................. 32 表32 万兆光接口模块(1550nm,40km)配置清单 (33)表33 百兆光接口模块(1310nm,2km)配置清单 ....................................................................33 表34 百兆光接口模块(1310nm,15km)配置清单 (33)表35 百兆光接口模块(1310nm,40km)配置清单 (33)表36 百兆光接口模块(1550nm,80km)配置清单 (34)表37 千兆SFP电接口模块(100m,RJ45)配置清单................................................................ 34 表38 千兆BIDI光模块(TX1310/RX1490,10km,LC)配置清单 ............................................... 34 表39 千兆BIDI光模块(TX1490/RX1310,10km,LC)配置清单 ............................................... 35 表40 百兆BIDI光模块-TX1310/RX1550,15km,LC配置清单 ................................................ 35 表41 百兆BIDI光模块(TX1550/RX1310,15km,LC)配置清单 ............................................... 35 表42 S5500-EI外部电源、电缆(光缆)的配置清单(国内版) ........................................ 36 表43 H3C S5500 系列以太网交换机国内版发货附件配置清单 ........................................... 37 表44 外部电缆/光缆列表 ..................................................................... (42)2011-08-28 版权所有,侵权必究第7页,共43页H3C S5500-EI以太网交换机配置手册(国内版) 机密图目录图1 S5500-28C-EI交换机前面板示意图 ..................................................................... ........... 9 图2 S5500-28C-EI交换机后面板示意图 ..................................................................... ......... 10 图3 S5500-28C-EI以太网交换机TOP面示意图 ...................................................................10 图4 S5500-28C-EI-DC交换机前面板示意图...................................................................... .. 10 图5 S5500-28C-EI-DC交换机后面板示意图...................................................................... .. 10 图6 S5500-28C-EI-DC以太网交换机TOP面示意图 ............................................................ 11 图7 S5500-52C-EI交换机前面板示意图 ..................................................................... ......... 11 图8 S5500-52C-EI交换机后面板示意图 ..................................................................... ......... 11 图9 S5500-52C-EI以太网交换机TOP面示意图 ................................................................... 12 图10 S5500-28C-PWR-EI交换机前面板示意图 (12)图11 S5500-28C-PWR-EI交换机后面板示意图 (12)图12 S5500-28C-PWR-EI以太网交换机TOP面示意图 ....................................................... 13 图13S5500-52C-PWR-EI交换机前面板示意图 (13)图14 S5500-52C-PWR-EI交换机后面板示意图 (13)图15 S5500-52C-PWR-EI以太网交换机TOP面示意图 ....................................................... 14 图16S5500-28F-EI(AC)交换机前面板示意图 (14)图17 S5500-28F-EI(AC)交换机后面板示意图 (14)图18 S5500-28F-EI(AC)以太网交换机TOP面示意图 ..................................................... 15 图19 S5500-28F-EI(DC)交换机前面板示意图 (15)图20 S5500-28F-EI(DC)交换机后面板示意图 (15)图21 S5500-28F-EI(DC)以太网交换机TOP面示意图 ..................................................... 16 图22 操作维护系统连接示意图 ..................................................................... ....................... 38 图23 新建连接 ..................................................................... ................................................ 39 图24 连接端口(串口)设置 ..................................................................... .......................... 40 图25 连接端口通信参数设置 ..................................................................... .......................... 40 图26 S5500-EI网管系统连接示意图 ..................................................................... (41)2011-08-28 版权所有,侵权必究第8页,共43页H3C S5500-EI以太网交换机配置手册(国内版) 机密H3C S5500-EI 以太网交换机配置手册V1.00(国内版)关键词:H3C S5500、以太网交换机、配置手册摘要:本文介绍了S5500-EI以太网交换机的国内版组成和配置原则,供配置产品使用,保证产品的正确组网,正确发货。
H3C S9500交换机策略路由功能的配置
H3C S9500交换机策略路由功能的配置一、组网需求:办公网为10.10.1.0/24网段,其核心交换机为S9500,由NE-1做NAT通过电信上Internet;由NE-2做NAT通过网通上Internet。
现要求10.10.1.0这个网段用户通过电信上Internet,10.10.2.0这个网段的用户通过网通上Internet,在S9500上进行策略路由配置。
二、组网图三、配置步骤软件版本:H3C S9500交换机全系列软件版本硬件版本:H3C S9500交换机全系列硬件版本1)配置vlan用户[S9500]vlan 101[S9500-vlan101]port Ethernet 2/1/11[S9500]interface vlan 101[S9500-Vlan-interface101]ip add 10.10.1.1 24[S9500]vlan 102[S9500-vlan101]port Ethernet 2/1/12[S9500]interface vlan 102[S9500-Vlan-interface102]ip add 10.10.2.1 242)配置NE1端出接口[S9500]vlan 103[S9500-vlan101]port Ethernet 2/1/13[S9500]interface vlan 103[S9500-Vlan-interface103]ip add 10.10.3.1 243)配置NE2端出接口[S9500]vlan 103[S9500-vlan101]port Ethernet 2/1/14[S9500]interface vlan 104[S9500-Vlan-interface104]ip add 10.10.4.1 245)配置策略路由[S9500]acl number 3011[S9500-acl-adv-3011] rule 0 permit ip source 10.10.1.0[S9500-acl-adv-3011] rule 1 permit ip source 10.10.2.0[S9500-Ethernet2/1/11]traffic-redirect inbound ip-group 3011 rule 0 next-hop 10.10.3.2[S9500-Ethernet2/1/12]traffic-redirect inbound ip-group 3011 rule 1 next-hop 10.10.4.2。
H3C S7500E系列交换机FAQ-6W100-整本手册
H3C S7500E系列交换机FAQCopyright © 2013 杭州华三通信技术有限公司版权所有,保留一切权利。
非经本公司书面许可,任何单位和个人不得擅自摘抄、复制本文档内容的部分或全部,并不得以任何形式传播。
本文档中的信息可能变动,恕不另行通知。
目录1 硬件特性 (1)S7500E系列交换机包含哪几种型号? (1)S7500E系列交换机包含哪些主控板? (1)不同机型如何选配主控板? (1)S7500E同一机箱内是否支持不同类型主控板的混配? (2)S7500E各款主控板的CPU、内存、Flash容量的指标分别是多少? (2)S7500E交换机是否支持CF卡?能否热插拔CF卡? (3)S7500E交换机主控板和业务板的配合使用有哪些限制? (3)如何查看S7500E交换机的单板类型? (3)“线速”的具体含义是什么? (3)S7500E系列交换机包含哪些业务板? (3)S7500E哪些单板支持远程供电(PoE)功能?端口最大输出功率为多少? (5)S7500E系列交换机是否支持40G接口?40G接口可选用什么类型的可插拔部件? (6)S7500E的万兆光接口板可选用哪些类型的光模块或者电缆? (6)S7500E的千兆光接口板可选用哪些类型的光模块? (8)S7500E的百兆光接口板可选用哪些类型的光模块? (8)S7500E交换机接口板、风扇、电源是否支持热插拔? (9)S7500E支持的电源类型有哪些? (9)S7500E交换机的交流电源和直流电源是否能同时使用? (10)S7500E电源系统的智能“功率管理”功能是怎么样的? (10)S7500E的电源有哪些保护措施? (10)S7500E各款设备的最大功耗是多少? (10)S7500E交换机的风扇是否支持自动调速? (11)S7500E交换机的工作温度以及告警上下限是多少? (11)S7500E对设备接地有什么要求? (11)S7500E交换机如何接地? (11)S7500E对防尘及腐蚀性气体有什么要求? (12)S7500E交换机抗电磁辐射干扰能力是怎么样的? (12)S7500E交换机的可靠性设计有哪些? (13)2 系统软件特性: (13)S7500E上如何查看当前运行版本? (13)能否删除S7500E正在使用的启动文件? (13)S7500E是否支持热补丁? (13)S7500E上如何保存系统当前运行的重要信息? (13)3 软件规格指标特性 (14)S7500E支持的MAC地址数为多少? (14)S7500E支持的ARP数为多少? (14)S7500E支持的VLAN数为多少?能使用的VLAN虚接口数为多少? (14)S7500E支持的路由数目为多少? (14)S7500E支持的ACL条数为多少? (15)4 二层特性 (15)S7500E是否支持端口镜像? (15)S7500E是否支持流镜像? (16)S7500E是否支持链路聚合(端口捆绑)? (16)S7500E的二层交换的丢包率、错包率、转发延时等具体指标? (16)S7500E支持的生成树有哪些? (17)S7500E如何批量修改端口配置? (17)什么是QinQ?S7500E是否支持QinQ? (18)什么是灵活QinQ?S7500E是否支持灵活QinQ? (18)5 路由特性 (19)S7500E支持哪些路由协议? (19)各种动态路由协议在协议栈中的位置,如何应用? (19)各种动态路由协议的算法是什么? (19)路由优选的原则是怎样的? (19)各种路由协议对GR、NSR、FRR、BFD的支持情况 (20)GR与NSR有何区别? (20)6 QoS和ACL特性 (21)S7500E系列产品的ACL/QOS支持哪些主要功能? (21)QoS策略可以在哪个方向应用?可以应用到哪些位置? (21)在QoS策略中,流分类可以匹配报文的哪些特征信息? (21)在入方向和出方向应用QoS策略时,流分类可以匹配的内容有何异同? (21)流行为中包含哪些动作? (22)在入方向和出方向应用QoS策略时,支持的流行为动作有何异同? (22)S7500系列交换机支持哪些拥塞避免功能? (23)7 安全特性和可靠性 (23)S7500E在安全性方面有哪些措施? (23)S7500E支持基于哪些认证方法的802.1X认证? (24)S7500E支持的RADIUS和HWTACACS协议有哪些区别? (24)EAPOL-Start报文源MAC为组播或广播MAC地址时能否触发802.1X认证? (24)如果客户端源IP为组播或广播IP地址,能否触发802.1X认证? (24)802.1X支持的EAD快速部署的实现机制是什么? (24)802.1X设置tx-period的作用是什么? (25)802.1X设置supp-timeout的作用是什么? (25)802.1X设置server-timeout的作用是什么? (25)802.1X设置handshake-period的作用是什么? (25)802.1X设置quiet-period的作用是什么? (25)802.1X的授权VLAN、Guest VLAN、Auth-Fail VLAN与Critical VLAN分别指什么? (25)怎样将802.1X认证和WindowsXP自带客户端软件配合使用? (26)用户在什么情况会加入到MAC地址认证的Guest VLAN? (26)用户在什么情况会加入到MAC地址认证的Critical VLAN? (26)MAC地址认证失败常见原因有哪些? (26)端口安全有哪些模式? (27)S7500E在可靠性方面有哪些措施? (28)S7500E是否支持Graceful Restart? (28)8 网管特性 (28)有哪些管理方式管理S7500E交换机? (28)SNMP支持哪些版本? (28)SNMP和RMON有什么关系? (28)sFlow采样机制有哪些? (28)9 组播特性 (29)S7500E设备对组播是如何支持的? (29)S7500E对IPTV目前有哪几种组网模式?分别采用何种组网方案? (29)S7500E的组播性能规格如何? (29)组播如何跨VLAN部署? (30)10 MPLS特性 (30)目前S7500E交换机支持哪些MPLS特性? (30)L2VPN支持哪些特性? (30)11 IRF技术特性 (31)S7500E满足IRF建立的条件? (31)S7500E所有机框类型都支持IRF吗? (31)S7500E设备最多支持几台设备组成IRF? (31)在S7500E设备上选择IRF链路时有什么特别要求? (31)不同S7500E设备可以支持混堆么? (31)S7500E设备所有类型主控板都支持IRF吗? (31)S7500E设备所有类型业务板都支持IRF吗? (31)S7500EIRF支持哪些拓扑? (32)IRF系统链形连接情况下的跨设备转发路径? (32)IRF系统环形连接情况下的跨设备转发路径? (32)IRF系统中的成员是怎样编号的? (33)S7500E在IRF系统中设备端口是怎样编号的? (33)多台设备组成IRF后,主控板之间是什么关系? (34)在IRF环境中,能够把备框的所有主控板都拔掉吗? (34)IRF系统中,各框的主控板怎样配置更合理? (34)多台设备组成IRF时,软件版本必须相同吗? (34)IRF设备进行框间主备倒换时,为什么要整框重启?能否做到不重启或者只主控板重启? (34)S7500E如何实现IRF分裂后的冲突检测和故障恢复?有哪些注意事项? (34)什么叫本地优先? (35)什么叫IRF异构? (35)S7500E设备对IRF端口有什么要求? (35)IRF端口两种工作模式有什么区别? (35)S7500E系列交换机FAQ1 硬件特性S7500E系列交换机包含哪几种型号?H3C S7500E系列交换机包括7款产品:S7502E、S7503E-S、S7503E、S7506E-S、S7506E-V、S7506E和S7510E。
H3C S9500E 系列路由交换机 IRF与FW ACG IPS插卡典型配置指导
H3C S9500E 系列路由交换机 IRF与FW ACG IPS插卡典型配置指导关键词:IPS、ACG、FW、典型配置指导摘要:介绍在95E堆叠下,FW&ACG&IPS插卡的推荐组网应用方案及典型配置指导。
缩略语:目录1 特性简介 (3)2 应用场合 (5)3 注意事项 (5)4 配置举例 (5)4.1 组网需求 (5)4.2 配置思路 (8)4.3 软件版本 (8)4.4 配置步骤 (10)4.4.1 配置S9500E (10)4.4.2 配置FW (30)4.4.3 配置IPS/ACG (31)4.4.4 OAA定位参考 (32)4.4.5 验证结果 (33)5 相关资料 (38)5.1 相关协议和标准 (38)5.2 其它相关资料 (38)1 特性简介当今网络世界,对网络设备的要求不再仅仅是传统的路由器和交换机提供的数据转发能力,更要求网络设备支持各种各样的应用。
而任何一家独立的技术厂商都很难同时提供客户所要求的所有服务。
所以,一种开放的架构——OAA,能够让众多不同厂商生产的设备和软件集成在一起,像一台设备那样工作,为客户提供一体化的解决方案。
基于这种理念,我司提出了OAA体系规范,H3C S9500E产品正是基于OAA规范开发了一系列应用业务方面的插卡,如无线插卡、安全插卡、防火墙插卡等。
OAA基本的体系结构如图1所示。
图1 OAA体系结构示意图从图中我们看到,OAA体系中,从硬件结构上看,可以分成三部分:路由交换部件、独立业务部件、接口连接部件。
其中,路由交换部件就是路由器和交换机的主体部分,这部分有着完整的路由器或交换机的功能,也是用户管理控制的核心;独立业务部件则是可以开放给第三方合作开发的主体,主要用来提供各种独特的业务服务功能;接口连接部件则是路由交换接部件和独立业务部件的接口连接体,通过这个部件将两个不同厂商的设备连接在一起,以形成一个统一的产品。
对于不同体系结构的产品,路由交换部件本身是存在差异的,如集中式的设备和分布式设备,体系结构上存在差异。
4 H3C 9500E系列交换机产品系统概述(山东电力培训使用)
H3C 9500E系列交换机产品系统概述ISSUE 1.0日期: 密级: 杭州华三通信技术有限公司 PDF 文件使用 "pdfFactory Pro" 试用版本创建 n 课程目标学习完本课程,您应该能够:n 了解9500E系列交换机型号和硬件结 构 n 了解S9500E系列交换机主控板和业 务接口板 n 掌握S9500E系列交换机主要软件特 性及应用PDF 文件使用 "pdfFactory Pro" 试用版本创建 ÿá 目录n S9500E交换机概述 n S9500E交换机体系结构及单板介绍 n S9500E 增强特性及主要应用PDF 文件使用 "pdfFactory Pro" 试用版本创建 全球最全面的交换机产品线NEW数据中心路 由交换机 H3C S12518NEWH3C S12508NEW核心路由 交换机H3C S7500E 全千兆智能 交换机H3C S9500H3C S9500ENEWH3C S5100SI/EI H3C S5500SI/EI H3C S5800系列智能二层/三层 交换机 H3C S3100SI/EI PDF 文件使用 "pdfFactory Pro" 试用版本创建 H3C S3600SI/EIH3C S3610H3C E系列 4目录n S9500E交换机概述 n S9500E交换机体系结构及单板介绍 n S9500E 增强特性及主要应用PDF 文件使用 "pdfFactory Pro" 试用版本创建 S9500E系列交换机产品定位l H3C S9500E是当前S9500的升级产品,主要硬件架构基 于S9500,接口板采用升级版ASIC芯片,软件平台采用 ComwareV5平台。
l 主要定位于以下应用: à大型城域网的汇聚层,小型城域网的核心层 à大型数据中心汇聚层,中小型数据中心核心层 à大型企业网及园区网的网络核心与汇聚层注:S9500E交换机所有单板与S9500交换机单板不通用。
H3C_S5500-EI[SI]系列以太网交换机_故障处理手册-6W100-整本手册
H3C S5500-EI&S5500-SI系列以太网交换机故障处理手册Copyright © 2014 杭州华三通信技术有限公司版权所有,保留一切权利。
非经本公司书面许可,任何单位和个人不得擅自摘抄、复制本文档内容的部分或全部,并不得以任何形式传播。
本文档中的信息可能变动,恕不另行通知。
目录1 ACL相关特性故障处理 (1)1.1 ACL下发失败故障处理 (1)1.1.1 故障描述 (1)1.1.2 故障处理流程 (2)1.1.3 故障处理步骤 (2)1.2 故障诊断命令 (3)2 IRF相关特性故障处理 (4)2.1 IRF建立失败故障处理 (4)2.1.1 故障描述 (4)2.1.2 故障处理流程 (4)2.1.3 故障处理步骤 (5)2.2 故障诊断命令 (6)3聚合相关特性故障处理 (6)3.1 聚合不成功故障处理 (6)3.1.1 故障描述 (6)3.1.2 故障处理流程 (7)3.1.3 故障处理步骤 (7)3.2 故障诊断命令 (8)4端口相关故障处理 (8)4.1 端口不Link up故障处理 (8)4.1.1 故障描述 (8)4.1.2 故障处理流程 (9)4.1.3 故障处理步骤 (9)4.2 故障诊断命令 (10)5其它常见故障处理 (11)5.1 CPU占用率高故障处理 (11)5.1.1 故障描述 (11)5.1.2 故障处理流程 (11)5.1.3 故障处理步骤 (11)5.1.4 故障诊断命令 (12)5.2 二层流量转发丢包 (12)5.2.1 故障描述 (12)5.2.2 故障处理流程 (13)5.2.3 故障处理步骤 (13)5.2.4 故障诊断命令 (15)5.3 三层转发丢包故障 (16)5.3.1 故障描述 (16)5.3.2 故障处理流程 (17)5.3.3 故障处理步骤 (17)5.3.4 故障诊断命令 (18)5.4 PoE供电异常 (18)5.4.1 故障描述 (18)5.4.2 故障处理流程 (18)5.4.3 故障处理步骤 (19)5.4.4 故障诊断命令 (20)本文档适用于H3C S5500-EI&S5500-SI系列以太网交换机Release 2208及以上版本。
H3C S7500E系列以太网交换机 安装手册(V1.18)-第5章 搭建IRF环境
目录5搭建IRF环境 ······································································································································ 5-15.1 搭建流程············································································································································ 5-15.2 规划IRF方案 ······································································································································ 5-25.2.1 搭建IRF前的准备 ···················································································································· 5-25.2.2 确定成员角色 ·························································································································· 5-35.2.3 确定各成员设备的编号 ··········································································································· 5-35.2.4 确定IRF的连接拓扑················································································································· 5-35.2.5 确定各成员设备上的IRF物理端口··························································································· 5-45.3 安装IRF成员设备······························································································································· 5-45.4 IRF系统软件配置······························································································································· 5-45.5 安装IRF连接线缆······························································································································· 5-45.6 登录验证············································································································································ 5-55 搭建IRF环境S7500E系列交换机支持IRF(Intelligent Resilient Framework,智能弹性架构)功能,您可根据需要将S7500E交换机通过10GE/40GE光口进行物理连接,并对设备进行相应的IRF配置,使其形成一个逻辑上的独立实体,从而构建具备高可靠性、易扩展性和易管理性的新型智能网络。
H3C S10500系列交换机 安全兼容性手册-6PW103-book
H3C S10500 Switch SeriesCompliance and Safety ManualHangzhou H3C Technologies Co., Ltd.Document version: 6PW103-20111130Copyright © 2011, Hangzhou H3C Technologies Co., Ltd. and its licensorsAll rights reservedNo part of this manual may be reproduced or transmitted in any form or by any means without prior written consent of Hangzhou H3C Technologies Co., Ltd.TrademarksH3C, , Aolynk, , H3Care, , TOP G, , IRF, NetPilot, Neocean, NeoVTL,SecPro, SecPoint, SecEngine, SecPath, Comware, Secware, Storware, NQA, VVG, V2G, V n G, PSPT, XGbus, N-Bus, TiGem, InnoVision and HUASAN are trademarks of Hangzhou H3C Technologies Co., Ltd.All other trademarks that may be mentioned in this manual are the property of their respective owners NoticeThe information in this document is subject to change without notice. Every effort has been made in the preparation of this document to ensure accuracy of the contents, but all statements, information, and recommendations in this document do not constitute the warranty of any kind, express or implied. Technical supportcustomer_service@Obtaining documentationYou can access the most up-to-date H3C product documentation on the World Wide Web at this URL: .The following are the columns from which you can obtain different categories of product documentation:[Products & Solutions]: Provides information about products and technologies, as well as solutions.[Technical Support & Document > Technical Documents]: Provides several categories of product documentation, such as installation, operation, and maintenance.[Technical Support & Document > Product Support > Software]: Provides the documentation released with the software version.Documentation feedbackYou can e-mail your comments about product documentation to info@.We appreciate your comments.Environmental protectionThis product has been designed to comply with the environmental protection requirements. The storage, use, and disposal of this product must meet the applicable national laws and regulations.ContentsSafety Information Sicherheits informationen安全信息 (1)Overview Überblick 概述 (1)Conventions Used Erläuterung der Symbole应用惯例 (2)Important Safety Information/Wichtige Sicherheitshinweise/重要安全信息 (3)Electricity Safety Elektrische Sicherheit 用电安全 (7)High Voltage Hochspannung高电压 (7)Regulatory Compliance Information (8)Regulatory compliance standards (8)European Directives compliance (8)LVD/EMC Directive (8)WEEE Directive–2002/96/EC (9)USA regulatory compliance (9)FCC Part 15 (9)FDA (9)Canada regulatory compliance (9)ICES-003 (9)Japan regulatory compliance (10)VCCI (10)EN55022,AS/NZS CISPR 22,CISPR22 compliance (10)Appendix A Regulatory compliance notices (11)Recycling notices (11)English recycling notice (11)Bulgarian recycling notice (11)Czech recycling notice (12)Danish recycling notice (12)Dutch recycling notice (12)Estonian recycling notice (13)Finnish recycling notice (13)French recycling notice (13)German recycling notice (14)Greek recycling notice (14)Hungarian recycling notice (14)Italian recycling notice (15)Latvian recycling notice (15)Lithuanian recycling notice (15)Polish recycling notice (16)Portuguese recycling notice (16)Romanian recycling notice (16)Slovak recycling notice (17)Spanish recycling notice (17)Swedish recycling notice (17)List of TablesTable 1 Safety symbol and description Sicherheitssymbole und Beschreibung安全标识和描述 (2)Table 2 Regulatory compliance standards (8)Safety Information Sicherheits informationen安全信息Overview Überblick 概述Warningmust read all of the Safety Instructions supplied with your equipment before installation and operation.Warnung警告负责安装和日常维护本设备的人员必须具备安全操作基本技能。
14-OAA命令参考-整本手册
H3C S9500E系列路由交换机OAA命令参考杭州华三通信技术有限公司资料版本:5W130-20110411产品版本:S9500E-CMW520-R1335Copyright © 2011 杭州华三通信技术有限公司及其许可者版权所有,保留一切权利。
未经本公司书面许可,任何单位和个人不得擅自摘抄、复制本书内容的部分或全部,并不得以任何形式传播。
H3C、、Aolynk、、H3Care、、TOP G、、IRF、NetPilot、Neocean、NeoVTL、SecPro、SecPoint、SecEngine、SecPath、Comware、Secware、Storware、NQA、VVG、V2G、V n G、PSPT、XGbus、N-Bus、TiGem、InnoVision、HUASAN、华三均为杭州华三通信技术有限公司的商标。
对于本手册中出现的其它公司的商标、产品标识及商品名称,由各自权利人拥有。
由于产品版本升级或其他原因,本手册内容有可能变更。
H3C保留在没有任何通知或者提示的情况下对本手册的内容进行修改的权利。
本手册仅作为使用指导,H3C尽全力在本手册中提供准确的信息,但是H3C并不确保手册内容完全没有错误,本手册中的所有陈述、信息和建议也不构成任何明示或暗示的担保。
前言H3C S9500E系列路由交换机命令参考共分为十四本手册,介绍了S9500E系列路由交换机各软件特性的配置命令行,包括每条命令对应的视图、参数、缺省级别、用途描述、举例等。
《OAA命令参考》主要介绍了OAA(Open Application Architecture,开放应用架构)相关的配置命令,包括OAP单板配置、ACFP配置、ACSEI配置。
前言部分包含如下内容:z读者对象z本书约定z产品配套资料z资料获取方式z技术支持z资料意见反馈读者对象本手册主要适用于如下工程师:z网络规划人员z现场技术支持与维护人员z负责网络配置和维护的网络管理员本书约定1.命令行格式约定格式意义粗体命令行关键字(命令中保持不变、必须照输的部分)采用加粗字体表示。
H3C最新产品手册
BOM编码型号1H3C S9500 路由交换机1H3C S7500E系列以太网交换机1H3C S7500系列以太网交换机1H3C S7502系列以太网交换机1H3C S5600系列以太网交换机1H3C S5510系列以太网交换机1H3C S5500-EI 以太网交换机1H3C S5500-SI 以太网交换机1H3C S5100-以太网交换机1H3C S3610系列以太网交换机1H3C S3600-以太网交换机1H3C S3100C-SI系列以太网交换机1H3C S3100TP-SI系列 以太网交换机1H3C S3100TP-EI 以太网交换机1H3C S2100-EI系列 以太网交换机1H3C低端交换机RPS冗余电源1H3C SR8800,万兆核心路由器1H3C SR6602 系列路由器1H3C SR6608&SR6604 系列路由器1H3C MSR 50系列路由器1H3C MSR 30系列路由器1H3C MSR 20系列路由器1H3C MSR 201X系列路由器1H3C 其他业务软件产品1H3C iMC智能管理中心1H3C SecPath 安全产品系列1H3C SecPath IPS系列1H3C SecCenter 安全管理中心系列1H3C SecPath应用加速系列1H3C SecPath IAG智能业务网关系列产品1H3C SecPath UTM系列安全产品1H3C 语音产品1H3C 视讯产品1H3C iVS 视频监控解决方案系列产品1Neocean EX1000 网络存储产品1Neocean 存储产品Disksafe捆绑组合1Neocean 存储产品配件1Neocean EX800 存储分销产品1Neocean DL1000S 虚拟磁带库1Neocean 存储产品捆绑组合1H3C SMB SOHO 系列产品1H3C WA1208E-无线局域网增强型接入2S101A28U30235A07X EWP-WA1208E-AG40235A07Y EWP-WA1208E-AGP50235A08A EWP-WA1208E-DG60235A08B EWP-WA1208E-G70235A32M EWP-WA1208E-GP8S101A28V90231A38Y EWP-WA1208E-WOU10S101A28W1127010210TQJ-SA800/2500-31227010215TQJ-2400-11-T21327010221TDJ-SA2400-18-651427010222TDJ-PST2400-23-08B1527010223TDJ-SA2400-17-901627010253TDJ-SA2400-11-90172701A002TQJ-2400BKF-Y182701A004SL13090A192701A008TQC-2400CI20S101A28X2127010239TDJ-DBS5800-172227010251TQJ-5800-12-T0232701A00A TDJ-5800P6242701A007SL13089A252701A003TDJ-2458BKC262701A009TQJ-2458XTJ1272701A00G TDJ-5158BKT60-228S101A28Y294041307CAB-PGND-Pwr-3m300404A04X CAB-RF-0.2m-SMA3114040150GM-ANT FED-1/23214040288BNC-RF-N-50-KK3325070076GM-JMP-13427020079SLPS-25023527020080SLPS-25043627020081SLPS-25033727110001N-50JR381902A001POE-MH390223A08X OANT-2.4G/5.8G400404A091CAB-RF-0.36m-(SMA+RG316)410404A08Y CAB-RF-1.83m-(N+RG8+SMA)420404A08V CAB-RF-1.83m-(2*NSM+RG8/U)430404A08W CAB-RF-4.5m-(2*NSM+RG8/U)440404A090CAB-RF-6.1m-(N+RG8+SMA)450404A08X CAB-RF-10m-(2*NSM+RG8/U)461404A008N-50JJ472711A000PSMA-50KR482130577FSP025-1AD207A491902A002MHT6000-N-1501902A000MHX100RJ45-1512702A000SL21357B522703A000CB-2412/2462MHz1H3C WA2200-无线局域网增强型接入点1H3C 无线控制器、一体华交换机与无线终端设备1H3C E300(E328,E352) 以太网交换机1H3C E152,E126A 以太网交换机广州市天齐科H3C金牌分销商,CISCO高级认证代理商,Juniper Netscreen高级代理商,深信服上网行为管理及VPN产品总代理,intel网卡钻石代理商!联系人:刘涛地址:成都市一环路南一段22号红瓦大厦1020室电话:028-********-806手机:134********QQ:3511891EMAIL:Satan999520@MSN:jacky999520@描述目录价格太网交换机务网关系列产品方案系列产品afe捆绑组合网增强型接入H3C WA1208E-主机0无线局域网AG双模接入点17700无线局域网AG双模大功率接入点22200无线局域网双G模块接入点16700无线局域网单G模块接入点13550无线局域网单G模块大功率接入点19000H3C WA1208E-室外机箱0无线局域网接入点室外单元模块1370H3C 无线局域网2.4GHz天线组件-全向&定向天线-802.11b/g0全向天线-824~960/1710~2500MHz-3dBi-垂直-360DEG-50W-0r-N150全向天线-2400-2500MHz-11dBi-垂直极化-150W-2r-N型母头-自620定向天线-2400-2500MHz-18dBi-65deg-vertical-0r-300W-自带2080定向天线-2400-2500MHz-23.5dBi-10.5deg-垂直极化-100W-0r-980定向天线-2400-2500MHz-17dBi-90deg-vertical-100W-0r-N型母2000定向天线-2400~2500MHz-11dBi-90deg-Vertical--0r-300W-wit460定向天线-2.4~2.483GHz-8.5dBi-80度-垂直极化-50W-N-K-否220全向天线-2.4~2.5GHz-5dBi-垂直极化-全向-10W-N-K-否95全向天线-2.4~2.483GHz-5.5dBi-垂直极化-50W-SMA-RP-否40H3C 无线局域网5.8GHz天线组件-全向&定向天线-802.11a0定向天线-5725~5850MHz-17dBi-25deg-垂直-50W-0r-N-Female-1130全向天线-5725~5850MHz-12dBi-垂直-12dBi-5W-0r-N(female)-870定向天线-5.725~5.85GHz-29dBi-6度-垂直或水平-100W-N-K-否1200全向天线-5.725~5.875GHz-5dBi-垂直极化-全向-100W-N-K-否95定向天线-2.4~2.5&5.15~5.85GHz-12&15dBi-45&20度-垂直极化760定向天线-2.4~2.5&5.15~5.85GHz-2.5&4.5dBi-360度-垂直极化170定向天线-5150-5850MHz-17dBi-60°-垂直极化-50W-N型680H3C WA1208E-发货附件0外部电源线-机箱PGND-12AWG-3m-(OT6-4)20射频电缆-0.2m-(SFF50-3)-(N50直公 to SMA50直母)48射频同轴连接器-N-50ohm-插头/直式-公-配1/2英寸超柔跳线-65射频同轴连接器-N-50ohm-直式-母-配接带N型头的电缆-双阴转28同轴电缆-铜包铝线-50ohm-13.5mm-8.7mm-3.55mm-黑色-超柔1/50无源分路器-2G/3G-1分2功分器-800~2500MHz-N(F)-180无源分路器-2G/3G-1分4功分器-800~2500MHz-N(F)-210无源分路器-一分三-微带线-800~2500MHz-N/female-无源190负载-0~8GHz-50ohm-<1.25-2W-N Male25信号避雷器-2.5KA@8/20us-300V@Line-Earth-10/100M PoE-RJ4220H3C WA1208E,WLAN 2.4GHz/5.8GHz室外天线安装套件500射频电缆-0.36m-50ohm-反极性SMA直母-(COAX-RG316)-反极性S31射频电缆-1.83m-50ohm-N50直公-(COAX-RG8/U)-反极性SMA直母76射频电缆-1.83m-50ohm-N50直公-(COAX-RG8/U)-N50直公92射频电缆-4.5m-50ohm-N50直公-(COAX-RG8/U)-N50直公140射频电缆-6.1m-50ohm-N50直公-(COAX-RG8/U)-反极性SMA直母155射频电缆-10m-50ohm-N50直公-(COAX-RG8/U)-N50直公235射频同轴连接器-N-50ohm-直式-公-配接N型接头的电缆-双阳转18负载-DC~12.4GHz-50ohm-<=1.25-1W-RSMA Female52一次电源-0degC-40degC-100V-240V-48V/0.5A-AC电源线可拆卸70天馈避雷器-10KA-20V-2.4~6.0GHz-100W-N-F/N-M255信号避雷器-3KA-230V±20%-1.5W-100Mbps-RJ-4595无源分路器-WLAN/3G-1分2功分器-1700~2500MHz-N(F)120合路器-WLAN-2412/2462MHz-NF650增强型接入点华交换机与无线终端设备以太网交换机天齐科技实业有限公司成都分公司H3C金牌分销商,CISCO高级认证代理商,Juniper Netscreen高级代理商,深信服上网行为管理及VPN产品总代理,intel网卡钻石代理商!联系人:刘涛地址:成都市一环路南一段22号红瓦大厦1020室电话:028-********-806手机:134********QQ:3511891EMAIL:Satan999520@MSN:jacky999520@。
H3C S9500E Series 路由器交换机快速启动指南说明书
H3C S9500E Series Routing SwitchesQuick Start GuideHangzhou H3C Technologies Co., Ltd.Copyright © 2003-2010, Hangzhou H3C Technologies Co., Ltd. and its licensorsAll Rights ReservedNo part of this manual may be reproduced or transmitted in any form or by any means without prior written consent of Hangzhou H3C Technologies Co., Ltd.TrademarksH3C, , Aolynk, , H3Care, , TOP G, , IRF, NetPilot, Neocean, NeoVTL, SecPro, SecPoint, SecEngine, SecPath, Comware, Secware, Storware, NQA, VVG, V2G, V n G, PSPT, XGbus, N-Bus, TiGem, InnoVision and HUASAN are trademarks of Hangzhou H3C Technologies Co., Ltd.All other trademarks that may be mentioned in this manual are the property of their respective owners.NoticeThe information in this document is subject to change without notice. Every effort has been madein the preparation of this document to ensure accuracy of the contents, but all statements, information, and recommendations in this document do not constitute the warranty of any kind, express or implied.Environmental ProtectionThis product has been designed to comply with the requirements on environmental protection. Thestorage, use, and disposal of this product must meet the applicable national laws and regulations.S9500E Installation Quick Start Guide About this guideThis guide provides steps for basic installation and configuration for the S9500E series. Furtherinformation, such as optional installation and configuration procedures are available in the S9500E Installation Guide.Product overviewThe S9500E series include the following models:•S9505E:The S9505E provides five line processing unit (LPU) slots and two MPU slots, horizontal•S9508E-V:The S9508E-V provides eight LPU slots and two main processing units (MPU) slots, vertical•S9512E:The S9512E provides twelve LPU slots and two MPU slots, horizontal Prepare for installationSafety recommendationsTo avoid possible bodily injury and equipment damage, read the following safety recommendations before installing an H3C S9500E switch. Note that the recommendations donot cover every possible hazardous condition.•Take adequate safety measures to avoid injury and switch damage.•Make sure that the ground is dry and flat and anti-slip measures are in place.•Keep the chassis clean and dust-free.•Do not place the switch in a moist area and avoid liquid surrounding the switch.•Keep the chassis and installation tools away from walkways.•Multiple people should move the switch and heavy components.Examine the installation siteThe H3C S9500E series can only be used indoors. Make sure that the floor can support theweight of the switch and its accessories.To ensure the normal operation of the switch, ensure that the following elements meet requirements described in “Preparing for installation” in the S9500E Installation Guide: roomtemperature; humidity, cleanness; EMS; grounding; power supply; space; and cabinet-mounting.Installation toolsTable 1 Required installation toolsCategory ToolMeasure andlineation tools Long tape, ruler (1 meter in length), gradienter, marking pen, powder marker, pencilDrills One percussion drill, several drill bits, one vacuum cleanerFastening tools Plain screwdriver P4 - 75 mmCross-head screwdriver P1 – 100 mm, P2 – 150 mm and P3 – 250 mm Box wrench M5Ring spanner M6Double ring spanner (10-12) or open ended spanner (10-12)Small tools Sharp-nose pliers, diagonal pliers, vices, hand-held electric drill, file, handsaw, crowbar, rubber hammerAuxiliary tools Brush, tweezers, paper knife, hand bellows, electric iron, solder wire, fork, ladderSpecial tools ESD-preventive wrist strap, cable stripper, crimping pliers, RJ-45 crimping pliers, wire punch-down toolMetersMultimeter, 500 V Meg-ohmmeter (used for measuring the insulation resistance), errordetector, optical power meter, earth resistance testerThe instruments and tools are not shipped with the S9500E series.Install the switchThis guide provides basic installation steps. See the S9500E Installation Guide for comprehensiveprocedures for installing the switch.To avoid bodily injury, do not touch any wire, terminal, or part marked with a high-voltage hazard sign.Installation workflowFigure 1 Installation flow of the switchInstall the switch on a rackThis S12500Quick Start Guide provides steps to install the switch on a rack. The S12500 Installation Guide also provides steps to install the S12500 on a workbench.This section explains how to install mounting and cable management brackets for the S9505E and S9512E. See the S9500E Installation Guide for steps on installing the mounting brackets and cable management brackets for the S9508E-V.Preparation•Check that the cabinet is well grounded and secured. Make sure the layout inside the rack for the switch installation is done and there is no debris left inside or around the cabinet.•There is enough space around the cabinet for heat-dissipation.Install the mounting brackets and cable management brackets for the S9505E and S9512E1.Install the cable management brackets on the mounting brackets with tapping screws.2.Attach the mounting brackets onto the left and right sides of the switch, as shown in Figure2.Figure 2 Install the mounting brackets and cable management brackets(1) Mounting brackets (2) Cable management bracket (3) Mounting screwsInstall the switch in the rack1.Place the switch on the support tray and slide the switch along the slide rails until themounting brackets on the switch reach the rack posts.e mounting screws to fix the mounting brackets to the rack posts.Connect the PGND cableThe switch must be well grounded. The resistance reading between switch chassis and the ground must be less than 1 ohm.Connection in generic grounding environmentThis section describes connecting in a generic grounding environment. See the S9500 Installation Guide for methods for grounding the switch in different grounding environments.1.Remove the screw from the grounding hole on the switch chassis.2.Put the supplied OT terminal of the PGND cable on the grounding screw.3.Insert the grounding screw into the grounding hole and screw it down.4.Connect the other end of the PGND cable to the grounding strip of the cabinet.Install a power systemSee the S9500 Installation Guide for instructions for installing a power system.Install a cardBefore installing a card, follow these preparations.1.Put on an ESD-preventive wrist strap and make sure that the wrist strap is properlygrounded.2.Remove the blank panel (if any) from the slot to be used.3.Prepare the card to be installed.Follow these steps to install a card:1.Move the ejector levers outwards, hold the module by the handle, and push the board intothe slot along slide rails slowly.2.Push the ejector levers inward to ensure a firm contact between the board and thebackplane.3.Position the screws into the holes and fasten them with a screwdriver to fix the board. Install a fan trayThis guide provides steps to install a fan tray for an S9505E or S9512E. See the S9500E Installation Guide for steps to install a fan tray for an S9508E-V1.Put on an ESD-preventive wrist strap and make sure the wrist strap is well grounded.2.Push the fan tray along the guide rails until it has a good contact with the backplane.3.Fasten the screws on the fan tray panel.Log in to the switchConnect the console cableThis section provides information on connecting the console cable. See the S9500E Installation Guide for information on connecting the AUX cable, network cables and optical fibers.1.Plug the DB-9 female connector of the console cable to the serial port of the PC or terminalwhere the switch is to be configured.2.Connect the RJ-45 connector of the console cable to the console port of the switch.Set up a configuration environmentunch a terminal emulation utility. Select Start > Programs > Accessories >Communications > HyperTerminal to access the HyperTerminal window. Click inthe window to set up a new connection. The Connection Description dialog boxappears.2.Enter the name of the new connection in the Connection Description dialog box, andclick OK. Select a port from the Connect using drop-down list.3.Set serial port parameters. Set the bits per second to 9600, data bits to 8, parity to None,stop bits to 1, and flow control to None.4.Click OK to enter the HypterTerminal window,5.Select File > Properties in the HyperTerminal window to access the Properties window.Click Settings in the Window, select VT100 for terminal emulation, and click OK. Power on the switchTo power on the switch, perform the following steps:1.Turn on the power switch of the power source providing power to the switch.2.Turn on the power switch of the PWR on the switch.H3C recommends that you check the following conditions after the switch is powered on:•The cooling system is working (you can hear the noise caused by fan rotation and feel air exhausted out.)•All the system LEDs on the MPUs function normally.•All the LEDs on the PSUs function normally. Input LED IN and output LED OUT is on, and the fault LED FAIL is off.Verify the installationMake sure that you have turned off the power before checking the installation to avoid bodily injury and device damage.After installing the switch, verify the installation against the following list. For the successful installation, all items must be normal.Table 2 Installation checklistItem ResultRemarks Yes NoThe PGND cable is correctly grounded.Fan trays are correctly installed and have a tight contact with the backplane.PSUs are correctly installed and have a good contact with the frames.Power cords are correctly connected.MPUs are correctly installed and have a good contact with the backplane.Item ResultRemarks Yes NoInterface cards are correctly installed and have a good contact with the backplane.The console cable is correctly connected.。
H3C S9500E 系列路由交换机
H3C S9500E 系列路由交换机S9508EH3C S9500E系列核心路由交换机是杭州华三通信技术有限公司(以下简称H3C 公司)面向园区网核心和数据中心市场推出的新一代核心路由交换机。
S9500E 在提供大容量、高性能L2/L3交换服务基础上,进一步融合了硬件IPv6、硬件MPLS、安全、业务分析等智能特性,可为园区网、数据中心构建融合业务的基础网络平台,进而帮助用户实现IT资源整合的需求。
S9500E采用创新的硬件设计,通过独立的控制引擎、检测引擎、维护引擎为系统提供强大的控制能力和50ms的高可靠保障;通过基于分布式的高性能硬件转发和大容量Crossbar无阻塞交换技术,保障了系统的高处理性能和灵活的扩展能力;通过OAA开放架构,实现了网络和安全、无线的融合。
H3C S9500E系列核心路由交换机包含如下型号:S9505E:5个业务板插槽,2个主控板插槽;S9508E/S9508E-V:8个业务板插槽,2个主控板插槽;S9512E:12个业务板插槽,2个主控板插槽。
创新的体系架构保障业务的高可靠S9500E采用了创新的硬件设计,通过独立的控制引擎、检测引擎、维护引擎为系统提供强大的控制能力和50ms的高可靠保障。
独立的控制引擎,提供强大的主控CPU,轻松处理各种协议报文及控制报文,并支持协议报文精细控制,为系统提供完善的抗协议报文攻击的能力;独立的检测引擎,提供高可靠和高性能的FFDR(Fast Fault Detection and Restoration-快速故障检测及恢复)CPU系统,该CPU系统专门用于BFD等快速故障检测,并与控制平面的协议实行联动,支持快速保护切换和快速收敛,可以实现50ms的故障检测,保障业务不中断;独立的维护引擎,智能化的EMS(Embedded Maintenance Subsystem-嵌入式维护子系统) CPU系统,该CPU系统支持电源智能管理,可以支持单板顺序上下电(降低单板同时上电带来的电源冲击,提高设备寿命,降低电磁辐射,降低系统功耗)等功能。
H3C E528[E552]以太网交换机 安全手册-6W100-整本手册
目录1 安全信息 (1)1.1 概述 (1)1.1.1 应用惯例 (1)1.1.2 通用要求 (1)1.2 用电安全 (2)1.2.1 高电压 (2)1.2.2 电缆 (2)1.2.3 防雷击 (3)1.3 保险丝 (3)1.4 辐射 (3)1.5 产品符合中国CCC认证要求 (3)1 安全信息1.1 概述本章节介绍了在安装、日常维护本系列设备时,必须遵循的安全预防规范。
为了避免可能发生的事故,请在进行任何操作前,仔细阅读设备操作手册和本章节的安全规范。
手册中出现的说明、注意、警告、危险,不能涵盖所有的安全预防,仅仅是在整个操作过程中的安全提示和补充。
因此,负责安装和日常维护本设备的人员必须具备安全操作基本技能。
操作人员要按照当地的安全规范进行操作。
出现在产品手册中的安全预防措施仅仅是当地安全规范的补充。
在操作本设备时,请认真执行产品手册规定的安全规范。
设备安装、维护人员必须通过专业培训,并且掌握足够的操作技能和安规预防意识。
只有专业人员才能担任本设备的安装和维护工作。
1.1.1 应用惯例以下表格中的安全标识,是用来提示读者在进行设备安装和维护时的安全预防要求。
表1-1安全标识和描述1.1.2 通用要求为了避免对人和设备造成伤害,请认真执行下列要求:z在进行操作前仔细阅读手册内容。
z设备必须安装在指定位置。
z进行设备安装时,必须确保接地连接是最先连接和最后断开。
z设备在工作时必须确保通风口的畅通,确保设备离墙壁或是其它的可能堵塞通风口的物体的间距至少5cm。
z不允许破坏设备的接地导线或是在无接地连接的情况下操作设备,要进行适当的电气检查。
z进行设备/系统操作前,请确保永久接地,并且用于进行保护接地连接的接地线截面不小于0.75mm2。
z AC电源输入:此设备用于TN电源系统。
z AC供电:插座必须随时可用,因为它是主要的切断电源装置。
z为了避免光纤发出的高能量的激光光束伤害到视网膜,请不要直视光接口。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
H3C S9500E Series Routing SwitchesCompliance and Safety ManualHangzhou H3C Technologies Co., Ltd.Manual Version: 5W103-20101119Copyright © 2009-2010, Hangzhou H3C Technologies Co., Ltd. and its licensorsAll Rights ReservedNo part of this manual may be reproduced or transmitted in any form or by any means without prior written consent of Hangzhou H3C Technologies Co., Ltd.TrademarksH3C, , Aolynk, , H3Care, , TOP G, , IRF, NetPilot, Neocean, NeoVTL, SecPro, SecPoint, SecEngine, SecPath, Comware, Secware, Storware, NQA, VVG, V2G, V n G, PSPT, XGbus, N-Bus, TiGem, InnoVision and HUASAN are trademarks of Hangzhou H3C Technologies Co., Ltd.All other trademarks that may be mentioned in this manual are the property of their respective owners.NoticeThe information in this document is subject to change without notice. Every effort has been made in the preparation of this document to ensure accuracy of the contents, but all statements, information, and recommendations in this document do not constitute the warranty of any kind, express or implied. Technical Supportcustomer_service@Obtaining DocumentationYou can access the most up-to-date H3C product documentation on the World Wide Web at this URL: .The following are the columns from which you can obtain different categories of product documentation: [Products & Solutions]: Provides information about products and technologies, as well as solutions.[Technical Support & Document > Technical Documents]: Provides several categories of product documentation, such as installation, operation, and maintenance.[Technical Support & Document > Product Support > Software]: Provides the documentation released with the software version.Documentation FeedbackYou can e-mail your comments about product documentation to info@.We appreciate your comments.Environmental ProtectionThis product has been designed to comply with the requirements on environmental protection. For the proper storage, use and disposal of this product, national laws and regulations must be observed.Table of Contents1 Regulatory Compliance Information········································································································1-1Regulatory Compliance Standards·········································································································1-1 European Directives Compliance············································································································1-1 LVD/EMC Directive··························································································································1-1 WEEE Directive–2002/96/EC··········································································································1-2 USA Regulatory Compliance··················································································································1-2 FCC Part 15·····································································································································1-2 FDA··················································································································································1-2 California Code of Regulations········································································································1-3 Canada Regulatory Compliance·············································································································1-3 ICES-003·········································································································································1-3 Japan Regulatory Compliance················································································································1-3 VCCI················································································································································1-3 CISPR 22 Compliance····························································································································1-32 Safety Information Sicherheits informationen安全信息·········································································2-1Overview Überblick 概述·························································································································2-1 Conventions Used Symbole Erläuterung应用惯例··········································································2-2 General Requirements Allgemeine Anforderungen通用要求··························································2-3 Electricity Safety Elektrische Sicherheit 用电安全··················································································2-5 High Voltage Hochspannung高电压································································································2-5 Power Cable Zuleitung电缆·············································································································2-6 Thunderstorm Gewitter 防雷击········································································································2-7 Laser Laser激光辐射·······················································································································2-8 Connection to AC power source Anbindung an Wechselstromquellen连接到交流电源·················2-91 InformationRegulatory ComplianceRegulatory Compliance StandardsTable 1-1nce standardsRegulatory compliaDisciplineStandardsEMC47) CLASS ALASS APR22 CLASS A-3-3386FCC Part 15 (CFRICES-003 CLASS AVCCI-3 CLASS ACISPR 22 CLASS AEN 55022 CAS/NZS CISCISPR 24EN 55024EN 61000-3-2EN 61000ETSI EN 300GB 9254GB 17625.1Safetyo 60950-111-2FDA 21 CFR Subchapter J GB 4943UL 60950-1CAN/CSA C22.2 NIEC 60950-1EN 60950-1/AAS/NZS 6095EN 60825-1EN 60825European Directives ComplianceLVD/EMC DirectiveH3C S9500E Series Routing Switches comply with the European Low Voltage Directive 2006/95/EC and EMC Directive 2004/108/EC.A copy of the signed Declaration of Conformity can be downloaded from:hnical_Documents /portal/TecWEEE Directive–2002/96/ECThe products this manual refers to are co Directive and must be disposed of in a re vered by the Waste Electrical & Electronic Equipment (WEEE) sponsible manner.latory ComplianceFCC Part 15C art 15 of the FCC Rules. Operation is subject to zause harmful interference. the equipment incompliance with FCC requirements for Class A digital devices, H3C is not liable for such interference problem and the expenses incurred therefrom shall be covered by the A Regu H3 S9500E Series Routing Switches complies with P the following two conditions:This device may not c z This device must accept any interference received, including interference that may causeundesired operation.If the customer modifies the equipment without the authorization of H3C, which directly or indirectly contribute toThis equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the ser will be required to correct the interference at his own expense. uFDAhes Conform to the applicable requirements of 21 CFR Subchapter JH3C S9500E Series Routing SwitcCalifornia Code of RegulationsCalifornia Code of Regulations, Title 22, Chapter 33 - Best Management Practices for Perchlorate Materials.Can his Class [A] digital apparatus complies with Canadian ICES-003.Cet appareil numérique de la classe [A] est conforme à la norme NMB-003 du Canada.Japan Regulatory ComplianceVCCI Switches complies with the requirements of VCCI Class A Informationtake corrective actions.CISP H3C S9500E Series Routing Switches complies with the requirements of CISPR 22 for Class A Information Technology Equipment (ITE).Warning: If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions.ada Regulatory ComplianceICES-003TH3C S9500E Series Routing Technology Equipment (ITE). Warning: If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to R 22 Compliance2 Safety Information Sicherheits informationen 安全信息 Ove ty statements and warnings, there followed the ents.nitt macht Sie mit den Sicherheitsvorschriften vertraut, die Sie bei der Installation und ng der Ausrüstung beachten müssen.rview Überblick 概述This section introduces part of the safety precautions that should be followed during the installation and maintenance of the equipment. And for the safe translations of both German and Chinese to comply with the national requirem Dieser Absch Instandhaltu 本章节介绍了在安装、日常维护本系列交换机时,必须遵循的安全预防规范。