<2kg 工作环境温度:-5°C~45°C 储存环境温度:-40°C~70°C 工作环境最大相对湿度:5%~95%,非凝结 抗震:抗 7 级地震烈度 散热:散热片(2826A);强制风冷(2826A-PS)
! set poe-port 1 enable set poe-port 2 enable set poe-port 3 enable set poe-port 4 enable set poe-port 5 enable set poe-port 6 enable set poe-port 7 enable set poe-port 8 enable set poe-port 9 enable set poe-port 10 enable set poe-port 11 enable set poe-port 12 enable set poe-port 13 enable set poe-port 14 enable set poe-port 15 enable set poe-port 16 enable set poe-port 17 enable set poe-port 18 enable set poe-port 19 enable set poe-port 20 enable set poe-port 21 enable set poe-port 22 enable set poe-port 23 enable set poe-port 24 enable

中兴 ZXR10 8900E 系列交换机数据手册说明书

中兴 ZXR10 8900E 系列交换机数据手册说明书

ZTE ZXR10 8900E Series Switch Data Sheet Updated: Sep 27, 2017Product OverviewThe ZXR10 8900E Series switch is high-end modular switch featuring big switching capacity, L2/L3/MPLS service capability, high-performance, superior reliability and enhanced security. The ZXR10 8900E Series switch is designed for core and aggregation layer of next-generation campus network scenario. The ZXR10 8900E Series switch allows fast, non-blocking switching and has full IPv6 feature. In addition, The ZXR10 8900E Series switch offers a variety of technologies to fulfill better reliability, easy maintenance and low power consumption: VSC2.0(Virtual Switch Cluster), BFD (Bi-directional Forwarding Detection), Zero-touch provisioning, IEEE 802.3az Energy Efficient Ethernet (EEE) etc, which help customer to build future-oriented low TCO(Total Cost of Ownership) networks.The ZXR10 8900E Series switch uses advanced hardware architecture and modular design, up to 10.24Tbps wire-speed switching capacity with high capacity service cards including: 48 x10GE interfaces, 8 x 40GE interfaces, and 4 x100GE interfaces.Coupled with distributed ROSng Software Platform, the ZXR10 8900E Series switch delivers the following products:● 8902E: 2 interface board slots, 2 control board slots and 2 power supply module slots. 4RU, side-to-side airflow.● 8905E: 5 interface board slots, 2 control switching slots and 3 power module slots. 10RU, side-to-side airflow.● 8908E: 8 interface board slots, 2 control switching slots and 3 power module slots. 13RU, side-to-side airflow.8902E 8905E 8908E 8912E 8908E‐H 8912E‐H● 8912E: 12 interface board slots, 2 control switching slots and 3 power module slots. 17RU, side-to-side airflow.● 8908E-H: 8 interface board slots, 2 control board slots, 4 independent switching fabric board slots and 3 power module slots. 17RU, side-to-side airflow.● 8912E-H: 12 interface board slots, 2 control board slots, 4 independent switching fabric board slots and 3 power module slots. 21RU, side-to-side airflow.Product Features• Up to 10.24Tbps Wire-speed Switching Capacity, 4 x 100GE/ 48 x 10GEInterface Card-The ZXR10 8900E Series switch supports up to 10.24Tbps wire-speed switching capacity with up to 1.28Tbps switching capacity per slot. It can deliver customer a sustainable high-performance campus core and aggregation network and carrier aggregation network for next 5 years. -The ZXR10 8900E Series switch line cards covers diverse Ethernet interfaces including: FE/GE/10GE/ 40GE/100GE.The high capacity line cards such as 48 ports wire-speed 10GE, 8 ports wire-speed 40GE and 4 ports wire-speed 100GE can bring customers with infinite bandwidth capability. Meanwhile, in the scenario that only need a few 10GE and GE interfaces, the 10GE and GE interface mixed line card can be deployed in order to help customer increase the line card usage and save investment.• Innovative VSC2.0 (Virtual Switch Cluster) Technology-VSC2.0 Capability: Stacking bandwidth between the VSC switches can be up to 320Gbps, which can solve the bandwidth bottleneck of VSC and deliver customer a real-time non-blocking VSC system. By using optical Ethernet interface for stacking, the stacking distance can be up to 80km and even more, it helps customer to get rid of distance restriction while designing a reliable VSC system. -Reliability: Independent out-band management makes the control plane and forwarding plane separated. Through real-time control information hot-standby technology, the VSC system can achieve seamless switchover when failure happens.- Saving investments: No need special stacking line card, the normal line card can be used for VSC connecting. When some interfaces are used for VSC, the other interfaces on this line card can also be used for traffic forwarding. No interfaces are wasted and that helps customer to save investments.- Flexibility: Master and slave in VSC2.0 works in 1+N redundancy mode, MAD(Multi-active Detect) technology is used to detect and avoid dual master in VSC system when failure happens. Together with real-time hot-standby and seamless switchover it brings customer a more flexible VSC network.• Powerful Service Bearing Capability-By supporting rich L2 switching and L3 routing functions and low latency forwarding, The ZXR10 8900E Series switch can bear lots of service including WLAN, Internet, Voice, Video, Enterprise private network and other data services. -Support distributed L2/L3 MPLS VPN; support VPLS, H-VPLS and VPWS. The ZXR10 8900E Series switch can also support MCE. By supporting these features, it delivers customer VPN service capability. -Support comprehensive L2/L3 Multicast protocols; support PIM-SM, PIM-DM, PIM-SSM, MLD and IGMP Snooping, fulfill the requirements for IPTV, multi-terminal high-definition video surveillance and video conferencing services. -Support POE/POE+ interface card, which delivers customer more flexible service access choice.• Comprehensive IPv6 Solution-The ZXR10 8900E Series switch has passed IPv6 Ready Phase 2 Gold Medal Certification issued by IPv6 Forum. -Support rich IPv6 unicast routing protocols: IPv6 static routing, RIPng, OSPFv3, IS-ISv6, and BGP4+ and multicast features: MLD v1/v2, MLD snooping, PIMv6, etc. -Support rich IPv4-to-IPv6 tunnel technologies: IPv6 manual tunnels, 6-to-4 tunnel, ISATAP tunnel and IPv4-compatible automatic tunnel, etc.• Enhanced Reliability, Multi-Dimensional Security-Control plane and forwarding plane are physically separated on the ZXR10 8900E-H Series switch. -All the key components of the ZXR10 8900E Series switch are redundant design and hot pluggable, including: main control boards, switching boards, power supply modules, fan modules. -Support GR (Graceful Restart) to realize non-stop forwarding for OSFP/BGP/IS-IS to reduce the affection brought by network failures. -Support Ethernet OAM, including IEEE 802.3ah, 802.1ag, Y .1731, and help to monitor network real-time operating status and fulfill fast fault detection, fault location. -Support various authentication methods such as 802.1x, Radius, TACACS+. Support CPU overload protection, anti-DDOS, deliver customer a security network. -The ZXR10 8900E supports MAC security (MACSec) that enables hop-by-hop secure data transmission. Therefore, the ZXR10 8900E can be applied to scenarios that need high requirements on data confidentiality, such as government and finance sectors.• Easy Maintenance, Saving OPEX-Support independent monitoring plane, which can monitor the working temperature, fan situation, power situation, etc. It can help customer hold the network running status in real time. -Support Zero-touch provisioning, the software and the configuration files can be loaded automatically, Reduce provision process and man power requirement. -Support the SQA (Service Quality Analyzer), detecting the network quality periodically or in real time. In order to provide better quality of service for more valuable services.• Green for More-Support IEEE 802.3az EEE (Energy Efficient Ethernet), via chip-grade power management, interfaces and line card can automatically sleep when no traffic.- Side-to-side shoot-through airflow increases the heat dissipation efficiency. Save up to12% overall power consumption.- The fan rotational speed can be automatically and manually adjusted by 5 levels in accordance with the temperatures inside the switch. It not only saves the power consumption, but also reduces the noise and extends the life cycle of fans.- Complying with ROHS, WEEE and ISO14001 certification, No plumbum (Pb) in not only product materials but also the whole processing technic. Meanwhile, use re-cycles degradable packing materials, practice green for more.System SpecificationParameters 8902E 8905E 8908E 8912E 8908E-H 8912E-H Height 4RU 10RU 13RU 17RU 17RU 20RU Dimensions (H*W*D, mm) 175*442* 420 442*442* 446 575*442* 446 753*442* 446 753*442* 446 889*442* 446 Switching Capacity 960Gbps4.8Tbps7.68Tbps7.68Tbps10.24Tbps10.24TbpsPacket ForwardingRate 720Mpps 3,600Mpps 5,760Mpps 5,760Mpps 7,680Mpps 7,680MppsNumber of Line Card Slots 2 5 8 12 8 12Number of Main ControlSlots 2 2 2 2 2 2Number of Switching Card Slots N/A N/A N/A N/A 4(3+1) 4(3+1)Interface Type FE/GE RJ45; GE SFP; 10GE SFP+; 40GE CFP; 40GE QSFP+; 100GE CFP2 Weight <24kg<51.8kg<65.5kg<90.6kg<77.4kg<98.9kgAC Power Supply Rated input voltage range: 100V~240V,50Hz~60Hz Max input voltage range: 90V~286V, 47Hz~63HzDC Power SupplyRated input voltage: -48V/-60V Input voltage range: -72V ~ -40VParameters 8902E 8905E 8908E 8912E 8908E-H 8912E-HHVDC Power Supply 240V/336VPower Consumption <576W <1,589W <2,278W <3,217W <2,624W <3,565W Max POE Consumption 1300W 4250W5100W5100W5100W5100WPower Redundancy Pattern AC/ DC: 1+1AC/DC :2+1/1+1Heat Dissipation Pattern Fan cooling,independent fan subracks, Side-to-Side AirflowHeat Dissipation <1,611 BTU/h <4,445 BTU/h <6,373 BTU/h <9,000 BTU/h <8,471 BTU/h <9,425 BTU/hWorking Temperature Long term working temperature: -5o C ~ +45o C; Short term working temperature: -10o C ~ +55o C;Storage temperature -40o C ~ +70o C Working Humidity 5%~95% (non-condensing)Working Altitude <3,000 metersMTBF/MTTR>200,000 hours/ <30 minutesService SpecificationFunctionThe ZXR10 8900E Series SwitchL2 Features Support IEEE 802.1p (COS), IEEE 802.1q (VLAN), IEEE 802.3x Support IEEE 802.1d (STP)/ 802.1w (RSTP)/ 802.1s (MSTP) Support IEEE 802.1ad (QinQ), Selective QinQSupport IEEE 802.3ad (LACP), MC-LAG (Multi-Chassis Link Aggregation Group)Support IEEE 802.3z (1000BASE-X) / 802.3ab (1000BaseT) Support IEEE 802.3ae (10Gbase), Support IEEE 802.3ba (40Gbase) Support IEEE 802.3ba (100Gbase)Support IEEE 802.3af (PoE), IEEE 802.3at (PoE+)Support Port mirroring, Traffic mirroring Support VLAN switching, VLAN translation Support PVLAN, SuperVLAN Support GVRP Support LLDPL3 FeaturesSupport IPv4 routing protocols, such as Static routing, Policy based routing , RIP, OSPF, BGP, and IS-ISSupport DHCP server/ relay/proxy, DHCP snoopingSupport IPv6 dynamic routing protocols, such as Static routing, Policy based routing , RIPng, OSPFv3, ISISv6, and BGP4+ Support ND, DHCPv6, PMTUSupport manual IPv6 tunnel, 6to4 tunnel, 6PE, ISATAP tunnel MulticastSupport IGMP v1/v2/v3, IGMPv1/v2/v3 snoopingSupport PIM-SM, PIM-DM, PIM-SSM, MSDP, MBGP, Any-RPSupport administratively scoped multicast/ IPTV, MVR, Support MLD V1/V2、MLD V1/V2 Snooping Support PIMv6MPLSSupport basic MPLS functions, LDPSupport MCESupport VPLS,VPWS, H-VPLS Support MPLS L2 VPN, MPLS L3 VPNQOSSupport traffic classification based on Layer 2 headers, Layer 3 protocols, Layer 4 protocols, and 802.1p prioritySupport queue scheduling algorithms, such as SP, WRR, DWRR, SP+WRR Support congestion avoidance mechanisms, such as WRED and tail drop Support policing/shaping based on port/flow SecuritySupport L2-L4 ACLSupport Ingress/ Egress ACLSupport 802.1x authentication and 802.1x serverSupport MAC authenticationSupport AAA/ RADIUS and TACACS+ authentication for login users Support SSH v1.0/v2.0 serverSupport CPU anti-attack, CPU overload protection, Support STP Root Guard, BPDU guard,Support URPFSupport RIP/OSPF/BGP MD5 encryption checking Support MACsecEquipment managementSupport CLI, Telnet, SSH, Local and remote (Radius/Tacacs+) authentication of user Support SNMP v1/v2/v3Support RMON Support NTP Support Syslog, Sflow Support openflow1.3ReliabilitySupport VSC2.0(Virtual Switch Cluster)Support 1+1/2+1 Redundant Control module/Power supply/Fan module Support 3+1 redundancy switching boards (Only 8900E-H) Support Hot plugging Support LACP , MC-LAGSupport ZESR/ZESR+ (ZTE Ethernet Switch Ring) Support ERPS V2Support VRRP,VRRPv3,VRRPE Support NSF/GR for OSFP/BGP/IS-IS Support BFD for VRRP/ BGP/ IS-IS/ OSPF Support Ethernet OAM (802.1ag and 802.3ah) Support ITU-Y.1731Application ScenarioAggregation in Campus NetworkThe ZXR10 8900E Series switch can be used in the next-generation campus network aggregation scenarios as the core/aggregation layer devices. The ZXR10 8900E Series switch supports powerful service capability such as L2/L3/MPLS, IPv6, POE, which provides 100GE, 40GE, high-density 10GE interfaces and fulfills the bearing requirements of WLAN, Voice, Video, Surveillance etc. It can be used to build the high-reliability, extendable, secure, manageable data switching network to provide the comprehensive product solution.Order InformationChassisRS-8902E-CHS 8902E assembly chassis 8905E-CHS2-AC 8905E AC assembly chassis 8905E-CHS2-DC 8905E DC assembly chassis 8908E-CHS2-AC 8908E AC assembly chassis 8908E-CHS2-DC 8908E DC assembly chassis 8912E-CHS2-AC8912E AC assembly chassis8912E-CHS2-DC8912E DC assembly chassis 8908E-H-CHS-AC8908E-H AC assembly chassis 8908E-H-CHS-DC8908E-H DC assembly chassis 8912E-H-CHS-AC8912E-H AC assembly chassis 8912E-H-CHS-DC 8912E-H DC assembly chassisControl Switching Board 8902EMCS1A8902E 1A type control switching board 8902EMCS1D8902E 1D type control switching board 8905EMCS1A8905E 1A type control switching board 8905EMCS1D8905E 1D type control switching board 8905EMCS3A8905E 3A type control switching board 8905EMCS3E8905E 3E type control switching board 8908EMCS1A8908E 1A type control switching board 8908EMCS1D8908E 1D type control switching board 8908EMCS3A8908E 3A type control switching board 8908EMCS3E8908E 3E type control switching board 8912EMCS1A8912E 1A type control switching board 8912EMCS1D8912E 1D type control switching board 8912EMCS3A8912E 3A type control switching board 8912EMCS3E 8902E 3E type control switching boardMain Control Board8900EHMCUA 8900E-H main control board Switching Fabric Board8900EHSFU3A8900E-H Type A switching fabric board 8900EHSFU3E 8900E-H Type B switching fabric board Power Supply Module8902E-ACPWA8902E AC power supply module 8902E-DCPWA8902E DC power supply module 8900E-ACPWA8905E/8908E/8912E/8908E-H/8912E-H AC power supply module 8900E-DCPWA 8905E/8908E/8912E/8908E-H/8912E-H DC power supply module Fan Supply Module8902E-FAN8902E fan subracks 8905E-FAN8905E fan subracks 8908E-FAN8908E fan subracks 8912E-FAN8912E fan subracks 8908E-H-FAN8908E-H fan subracks 8912E-H-FAN 8912E-H fan subracks100M/1000M Ethernet electrical interface cardsS1GT24A24-port 10/100/1000 BASE-T interface card (S1, RJ45) S1GT48A 48-port 10/100/1000 BASE-T interface card (S1, RJ45) S1GP48A48-port 10/100/1000 BASE-T interface card (S1, RJ45, POE/POE+) H1GT48A48-port 10/100/1000 BASE-T interface card (H1, RJ45) H2GT48D 48-port 10/100/1000 BASE-T interface card (H2, RJ45)100M/1000M Ethernet optical interface cardsS1GF24A24-port 100/1000 BASE-X interface card (S1, SFP) S1GF48A 48-port 100/1000 BASE-X interface card (S1, SFP)H1GF24A24-port 100/1000 BASE-X interface card (H1, SFP) H1GF48A48-port 100/1000 BASE-X interface card (H1, SFP) H2GF24D24-port 100/1000 BASE-X interface card (H2, SFP) H2GF48D 48-port 100/1000 BASE-X interface card (H2, SFP)10GE Ethernet optical interface cards S1XF12A12-port 10G BASE-X interface card (S1, SFP+) S2XF48A48-port 10G BASE-X interface card (S2, SFP+) H1XF4A4-port 10G BASE-X interface card (H1, SFP+) H1XF8A8-port 10G BASE-X interface card (H1, SFP+) H1XF16A16-port 10G BASE-X interface card (H1, SFP+) H1XF32A32-port 10G BASE-X interface card (H1, SFP+) H2XF8D8-port 10G BASE-X interface card (H2, SFP+) H2XF48C48-port 10G BASE-X interface card (H2, SFP+) H3XF12D 12-port 10G BASE-X interface card (H3, SFP+) 10 GE and GE optical/electrical interface cardsH1GF28C12X2C2-port 10GE BASE-X and 28-port GE BASE-X (12-port Combo) interface card (H1,SFP+/SFP/RJ45) H1GF28C12X4C4-port 10GE BASE-X and 28-port GE BASE-X (12-port Combo) interface card (H1,SFP+/SFP/RJ45) H1GT28C12X2B2-port 10GE BASE-X and 28-port GE BASE-T (12-port Combo) interface card (H1,SFP+/SFP/RJ45) H1GT28C12X4B 4-port 10GE BASE-X and 28-port GE BASE-T (12-port Combo) interfacecard (H1,SFP+/SFP/RJ45)40GE Ethernet optical interface cardsS2LQ6L2A 8-port 40GE BASE-X interface card (S2, 2 port CFP, 6 port QSFP+) 100GE Ethernet optical interface cardsH2UC2C2-port 100GE BASE-X interface card (H2, 2 port CFP2) H2UC4C 4-port 100GE BASE-X interface card (H2, 2 port CFP2) 10GE WAN optical interface cardsH1XW4B 4-port 10G BASE-X interface card (H1, SFP+) Software R8900E-SW-BASIC8900E Basic System Software R8900E-SWUD8900E Basic System Software Upgrade SWLIC-MPLS 8900E MPLS Software ServiceNO. 55, Hi-tech Road South,ShenZhen,P. R. China Postcode: 518057Web: Tel: +86-755-26770000Fax: +86-755-26771999。

中兴 ZXR10 5950-L 系列交换机数据手册说明书

中兴 ZXR10 5950-L 系列交换机数据手册说明书

ZTE ZXR10 5950-L Series Switch Data Sheet Updated: Dec 23, 2016Product OverviewThe ZXR10 5950-L Series switch is 1RU height all gigabit routing stackable switch for carrier access and aggregation scenarios. It provides up to 52 interfaces (48 GE+ 4 10GE). With VSC2.0 (Virtual Switch Cluster), it delivers improved resilience and flexibility. The ZXR10 5950-L Series switch supports full IEEE 802.3at Power over Ethernet Plus (PoE+) to fulfill more carrier access scenarios. Zero-touch provisioning, IEEE 802.3az Energy Efficient Ethernet (EEE) make the network not only easy for maintenance but also low consumption.The ZXR10 5950-L Series switch offers the following switch products:5950-28TD-L 5950-52TD-L5950-28TD-L: 24 Ethernet 10/100/1000M RJ45 electrical ports, 4 10GE SFP+ optical ports, 2 AC/DC power supply modules.5950-52TD-L: 48 Ethernet 10/100/1000M RJ45 electrical ports, 4 10GE SFP+ optical ports, 2 AC/DC power supply modules.5950-28PD-L 5950-52PD-L5950-28PD-L: 24 Ethernet 10/100/1000M RJ45 electrical ports (POE/POE+), 4 10GE SFP+ optical ports, 1 Fan Module, 2 AC/DC/HVDC power supply modules.5950-52PD-L: 48 Ethernet 10/100/1000M RJ45 electrical ports (POE/POE+), 4 10GE SFP+ optical ports, 1 Fan Module, 2 AC/DC/HVDC power supply modules.5950-28SD-L5950-28SD-L: 24 GE SFP optical ports, 4 10GE SFP+ optical ports, 1 Fan Module, 2 AC/DC/ HVDC power supply modules.Product Features•Powerful Service Bearing Capability-By supporting rich L2 switching and L3 routing functions and low latency forwarding, The ZXR10 5950-L Series switch can bear multiservice including WLAN, Internet, Voice,Video and other data services.-The ZXR10 5950-L Series switch supports comprehensive L2/L3 Multicast protocols: PIM-SM, PIM-DM, PIM-SSM, MLD, IGMP Snooping, Filtering, Proxy and Fast leave,MVR (Multicast VLAN Registration) to facilitate the deployments of these services. WithIPTV control implemented, operators can apply different CAC (channel access control)rules for users with channel packages.-Support POE/POE+, which delivers customer more flexible service access choice.-Flexible hardware forwarding table distribution, customers can configure the size of ARP table, MAC table according to actual need, to satisfy more application scenarios.•Innovative VSC2.0 (Virtual Switch Cluster) Technology-Support VSC2.0 (Virtual Switch Cluster), which enhances cluster system capacity and port density, simplifies network topology and management.-Real time hot-standby information synchronization between master and backup master to ensure seamless switchover against network failures, enhancing the networkreliability.-Stacking bandwidth between the VSC switches can be up to 80Gbps, which can solve the bandwidth bottleneck of VSC and deliver customers a real-time non-blocking VSCsystem.-Master and slave in VSC works in 1+N redundancy mode, MAD (Multi-active Detect) technology is used to detect and avoid dual master in VSC system when failure happens.Together with real-time hot-standby and seamless switchover it brings customer a moreflexible VSC network.•Comprehensive IPv6 Features-Support rich IPv6 unicast routing protocols: IPv6 static routing, RIPng, OSPFv3, IS-ISv6, and BGP4+ and multicast features: MLD v1/v2, MLD snooping, PIMv6,etc.-Support rich IPv4-to-IPv6 tunnel technologies: IPv6 manual tunnels, 6-to-4 tunnel, ISATAP tunnel and IPv4-compatible automatic tunnels, etc.•Flexible POE/POE+-Support POE and POE+ complying with the 802.3at and 802.3af standard to provide power supply for remote devices (including IP phones, WLAN APs, and networkcameras) through twisted-pair cables.-Support forcible power supply and could supply power for PD equipments that not compatible with 802.3af and 802.3at standards if needed.-Support configuring the POE time range. During the time that doesn’t need power supply, power supply can be stopped automatically to save energy.-Support PD port power detection. If the actual power is greater than the PSE-distributed power, stops providing power supply.-Support displaying the PSE power supply status and PD power supply status, such as whether power supply is provided, power, level, and temperature.•Carrier-Class Reliability, Multi-Dimensional Security-The ZXR10 5950-L Series switch supports ZESR+ Ethernet ring protection and ERPS, which can deliver the fast system recovery from any link or node fault-Support various authentication methods such as 802.1x, Radius, TACACS+. Support CPU overload protection, anti-DDOS, deliver customer a security network.•Low OPEX , Green for More-The innovative M-Button delivers instant trouble-shooting by reading indicators on front panel without login via terminal. It helps customer solve some common problemsimmediately.-Support IEEE 802.3az EEE (Energy Efficient Ethernet). Via chip-grade power management, interfaces can automatically sleep when no traffic.-The fan speed can be automatically adjusted by 5 levels in accordance with the temperature inside the switch. It not only saves the power consumption, but also reduces the noise and extends the life cycle of fans.-Complying with ROHS, WEEE and ISO14001 certification, No plumbum (Pb) in not only product materials but also the whole processing technic. Meanwhile, use re-cycledegradable packing materials, practice green for more.System SpecificationService SpecificationApplication ScenarioAccess and Aggregation in Carrier NetworkThe ZXR10 5950-L Series switch supports VSC2.0 and POE/POE+, they can be applied in multiple scenarios including carrier access. Below is an example of typical application.Order Information MainframePower ModuleFan ModuleNO. 55, Hi-tech Road South,ShenZhen,P. R. China Postcode: 518057Web: Tel: +86-755-26770000Fax: +86-755-26771999。

中兴交换机清配置步骤和命令

中兴交换机清配置步骤和命令

中兴交换机清配置步骤和命令1.登录交换机首先需要通过串口或Telnet等方式登录交换机,并输入正确的用户名和密码。

登录成功后,便可以开始进行后续的操作。

2.备份配置在清除配置之前,强烈建议备份交换机的配置文件,以便在需要的时候能够快速恢复原有的配置。

备份命令如下:```save configuration to tftp IP地址文件名.cfg```其中,IP地址为用于保存配置文件的TFTP服务器的地址,文件名.cfg为保存的配置文件名。

示例:```save configuration to tftp 192.168.1.100 backup.cfg```3.清除配置清除配置是指将交换机的所有配置信息恢复到出厂设置状态。

清除配置的命令如下:```erase configuration```示例:```erase configuration```执行该命令后,交换机将会提示用户确认是否继续,输入y后回车即可。

4.恢复出厂设置清除配置后,可以选择恢复出厂设置,将交换机的配置恢复到出厂默认状态。

恢复出厂设置的命令如下:```load factory-default```示例:```load factory-default```执行该命令后,交换机将会提示用户确认是否继续,输入y后回车即可。

5.保存并重启交换机执行以上步骤后,需要将交换机的当前配置保存并重启,以使修改生效。

保存配置的命令如下:```save configuration```示例:```save configuration```保存配置后,可以执行如下命令重启交换机:```reboot```示例:```reboot```执行该命令后,交换机将会重启,并应用新的配置。

以上就是中兴交换机清配置的基本步骤和命令。

需要注意的是,清除配置和恢复出厂设置是危险操作,应谨慎使用,并在确认无误后再执行。

另外,为了防止数据丢失,建议在执行清除配置和恢复出厂设置之前先备份重要的配置文件。

中兴交换机简明配置教程

中兴交换机简明配置教程

中兴交换机简明配置教程一、登录交换机二、基本配置3. 配置 VLAN。

在交换机配置界面中,找到 "VLAN Management" 或类似的选项,在其中创建需要的 VLAN 号,并将相应的端口加入到 VLAN 中,实现不同 VLAN 间的隔离和通信。

三、常用命令1. 查看交换机的基本信息。

使用命令 "show system" 可以查看交换机的型号、版本、序列号等基本信息。

2. 查看端口状态。

使用命令 "show interface brief" 可以查看交换机各个端口的状态,包括端口编号、状态、协商状态等。

3. 查看 VLAN 配置。

使用命令 "show vlan" 可以查看交换机的VLAN 配置信息,包括 VLAN 号、名称、端口等。

4. 配置端口的 VLAN。

使用命令 "config vlan vlan-id add tagged,untagged interface interface-id" 可以将指定端口加入到指定的 VLAN 中,其中 "vlan-id" 是 VLAN 号,"interface-id" 是端口编号。

5. 配置端口的速率和双工模式。

使用命令 "config interface ethernet interface-id speed-mode {10M_HALF,10M_FULL,100M_HALF,100M_FULL,1000M_FULL,AUTO}" 可以配置指定端口的速率和双工模式。

6. 配置端口的描述。

使用命令 "config interface ethernet interface-id description description" 可以为指定端口设置描述,方便管理和区分。

四、保存配置在设置完成后,为了保证配置的持久化,在命令行界面输入 "save"命令保存配置文件。

中兴交换机

中兴交换机

本地网虚拟网介绍及数据制作方法本地网交换机分为两种机型:华为CC08及中兴ZXJ10,两种机型在实现虚拟网的方法上存在很大差异,现分别加以说明。

一、华为CC08机1.华为虚拟网CENTREX基本概念1.1 Centrex的概念C&C08交换机将相关用户(比如同一个企业的用户)组织成一个商业用户群,称为Centrex群。

每个群内可设话务员,入群及群内呼叫。

Centrex用户除了享用公网用户基本呼叫及补充业务功能外,还可以享受类似于PABX(小交换机)的多种特别补充业务。

每个Centrex用户拥有两个号码:一个是公网上的统一编号,称为长号;一个是Centrex群内用户呼叫时使用的短号。

1.2 C&C08交换机Centrex的业务种类•具有公用网上的所有基本业务及补充业务。

●Centrex群内用户直拨群内分机。

●Centrex群内用户拔群外用户时,先拨出群字冠后,可听或不听二次拔号音,再拨群外号码。

●可根据需要设置Centrex用户呼叫权限级别,包括群内呼出,群内呼入,群外呼出,群外呼入。

●Centrex群内用户可拨话务员接入码或拨话务员分机号呼叫话务员。

2. Centrex用户数据配置一般步骤2.1. 增加Centrex用户数据一般步骤(1) 如果Centrex用户所属的呼叫源不存在,则增加相应的呼叫源(ADD CALLSRC);(2) 如果Centrex用户长号对应的呼叫字冠不存在,则增加相应的呼叫字冠(ADD CNACLD);(3) 如果Centrex用户长号对应的号段不存在,增加号段(ADDDNSEG);(4) 增加Centrex群(ADD CXGRP);(5) 增加Centrex群字冠(ADD CXPFX);(6) 增加Centrex出群字冠(ADD OCXPFX);(7) 如果配有Centrex话务台,增加Centrex话务台(ADD CXCON);(8) 增加Centrex用户(ADD ST/ADB ST、MOD ST/MOB ST、ADDDSL/ADB DSL、MOD DSL/MOB DSL、ADD V5ST/ADB V5ST、MOD V5ST/MOB V5ST、ADD V5DSL/ADB V5DSL、MODV5DSL/MOB V5DSL);(9) 增加Centrex群计费(ADD CHGCX)。

中兴ZXJ10程控交换机技术手册

中兴ZXJ10程控交换机技术手册

中兴ZXJ10程控交换机技术手册本文档旨在介绍《中兴ZXJ10程控交换机技术手册》的目的和重要性,并概述手册的内容和结构。

该技术手册详细描述了中兴ZXJ10程控交换机的特点、功能和技术规格。

中兴ZXJ10程控交换机是一种先进的通信设备,具有以下主要特点和功能:高度可靠性:中兴ZXJ10程控交换机采用了先进的硬件和软件设计,确保了其在通信过程中的稳定性和可靠性。

它可以在恶劣的环境下正常运行,并具备自动故障检测和恢复功能,以减少因故障导致的通信中断。

大容量和高性能:中兴ZXJ10程控交换机支持大规模的通信网络,具有高密度的端口和处理能力。

它能够处理大量的并发通话和数据传输,以满足不断增长的通信需求。

灵活的扩展性:中兴ZXJ10程控交换机支持模块化设计,可以根据需要进行灵活的扩展和升级。

它提供了多种接口和插槽,可以轻松地连接到不同类型的通信设备和网络。

先进的通信功能:中兴ZXJ10程控交换机支持多种通信协议和功能,如语音通话、数据传输、视频会议等。

它具有丰富的通信功能,能够满足各种不同的通信需求。

高级的管理和控制功能:中兴ZXJ10程控交换机提供了强大的管理和控制功能,可以对通信网络进行有效的监控和管理。

它支持远程配置和故障诊断,以提高操作和维护的效率。

通过阅读本技术手册,您将了解中兴ZXJ10程控交换机的详细技术规格、特点和功能,以及如何正确使用和配置该设备。

对于通信行业的专业人士和使用中兴ZXJ10程控交换机的用户来说,这是一份重要的参考资料。

提供中兴ZXJ10程控交换机的配置要求和安装指南,包括硬件和软件方面的步骤。

本技术手册为您提供了使用中兴ZXJ10程控交换机的基本操作和功能的介绍。

您将了解如何进行线路管理和呼叫控制等操作。

手册分为以下几个部分:安装和设置交换机的安装和搭建管理员账户的设置和权限管理系统初始化和配置线路管理线路的添加和删除线路的参数配置和调整线路的监控和故障排除呼叫控制呼叫的建立和结束呼叫转移和组合呼叫呼叫的定位和处理其他功能通话录音和回放通讯录的管理呼叫统计和报表生成本手册将详细介绍每个操作和功能,并提供相应的操作步骤和注意事项。

中兴交换机配置流程和配置命令

中兴交换机配置流程和配置命令

中兴交换机配置流程和配置命令配置流程:1.连接中兴交换机:使用网线连接中兴交换机的管理端口与电脑的网口,确保网络通畅。

2.设置电脑IP地址:将电脑的IP地址设置为与交换机的管理口在同一个网段,例如交换机管理口的IP地址是192.168.1.1,电脑IP地址可以设置为192.168.1.23.打开浏览器:打开电脑上的浏览器,通过输入交换机管理口的IP 地址进入交换机管理页面。

4. 登录交换机:输入交换机的默认用户名和密码进行登录,通常为admin/admin。

5.进入系统配置:登录成功后,进入系统配置界面,配置交换机的基本信息,例如主机名、域名等。

6.配置接口:配置交换机的各个接口,包括端口的状态、速率、双工模式等。

可以配置端口的VLAN、IP地址等信息。

7.配置VLAN:根据网络需求,配置交换机的VLAN信息,包括创建VLAN、配置VLAN端口等。

8.配置静态路由:配置交换机的静态路由,将需要进行转发的目的网络与对应的出口接口进行关联。

9.配置访问控制列表(ACL):根据网络安全需求,配置ACL来限制特定流量的通过或禁止。

10.配置QoS:配置交换机的QoS策略,用于对网络流量进行调度和优化,以满足不同应用的需求。

11.保存配置:完成以上配置后,通过保存配置将配置信息应用到交换机中,确保配置生效。

常用的配置命令:1. system-view:进入系统视图,进行全局配置。

2. interface interface-type interface-number:进入接口视图,配置接口相关信息。

3. ip address ip-address {mask , mask-length}:配置接口IP 地址。

4. vlan 10:创建VLAN10。

5. vlan-interface vlan 10:进入VLAN10的接口视图,进行VLAN 的相关配置。

6. vlan 10 to 20:创建VLAN10至VLAN20的VLAN。

中兴ZXR10 5960系列交换机数据表说明书

中兴ZXR10 5960系列交换机数据表说明书

ZTE ZXR10 5960 Series Switch Data Sheet Updated: Aug 18, 2016Product OverviewThe ZXR10 5960 Series switch is next-generation switch with high switching capacity and high port density for data center TOR and carrier access and aggregation scenario. It provides high density 10GE/40GE interfaces, carrier-class reliability and superior scalability. The ZXR10 5960 Series switch supports extensive data center service features such as VSC2.0 (Virtual Switch Cluster)/ TRILL (Transparent Interconnection of Lots of Links)/ Front-to-back Airflow and Ethernet ring protection for L2 Ethernet service. The ZXR10 5960 Series switch can work with the ZXR10 9900 Series switch to build an elastic, virtualized, high-quality switching network that meets the requirements of cloud-computing data centers.The ZXR10 5960 Series switch offers the following switch products:ZXR10 5960-32DL ZXR10 5960-64DL5960-32DL: 24 10GE SFP+ optical ports and 2 40GE QSFP+ optical ports, 2 fan module, 2 AC/DC/HVDC power supply modules, front-to-back airflow.5960-64DL: 48 10GE SFP+ optical ports and 4 40GE QSFP+ optical ports, 2 fan module, 2 AC/DC/HVDC power supply modules, front-to-back airflow.ZXR10 5960-64NL ZXR10 5960-28TM5960-64NL:48 10GE RJ45 electrical ports and 4 40GE QSFP+ optical ports, 2 fan modules, 2 AC/DC/HVDC power supply modules, front-to-back airflow.5960-28TM:24 Ethernet 10/100/1000M RJ45 electrical ports and one expansion slot, 2 fan modules, 2 AC/DC/HVDC power supply modules, front-to-back airflow.ZXR10 5960-52TM5960-52TM:48 Ethernet 10/100/1000M RJ45 electrical ports and one expansion slot, 2 fan modules, 2 AC/DC/HVDC power supply modules, front-to-back airflow.The expansion card slot can be equipped with the following expansion cards:● 4 * 10GE SFP+ optical ports card● 4 * GE SFP optical ports card● 4 * GE RJ45 electrical ports cardProduct Features•Up to 64×10GE Ports, 1RU Switch with 40GE Interface-The ZXR10 5960 Series switch supports up to 1.28Tbps wire-speed switching capacity with high density10GE/40GE interfaces. It delivers huge bandwidth capability to fulfill the growing service requirement in data center.-1RU switch supports up to 64×10GE ports when expand 40GE port into 4 10GE ports, in order to access large scale 10GE servers.-The 10 GE ports support working as GE ports, 40GE port can be expanded into 4 10 GE ports, flexible interface combination delivers easy deployment for TOR switch and savecost for customer.•Deliver Better Data Center Service Experience.-Support TRILL (Transparent Interconnection of Lots of Links) L2 multi-path technology and meet large L2 networking needs without STP. The load is shared between links andbandwidth resources usage is nearly 100%. The ZXR10 5960 Series switch can be used to build large L2 network with over 500 nodes, which can meet the requirement of VM(Virtual Machine) migration.-Support DCB (Data Center Bridging) protocol family and fully guarantee network reliability and no loss in full range. The ZXR10 5960 Series switch supports PFC(Priority-based Flow Control), QCN (Quantized Congestion Notification), ETS (EnhancedTransmission Selection), DCBX (Data Center Bridging Exchange), which ensure lowlatency and zero packet loss for high-speed computing services.-Support multiple EVB (Ethernet Virtual Bridging) patterns including VM, VEB and VEPA (Virtual Ethernet Port aggregator), and these different patterns can coexist, so it can fulfilldifferent networking requirements. With full support for related protocols like VDP (VSIDiscovery Protocol), EDCP (Edge Devices Communication Protocol) and CDCP(S-Channel Discovery and Configuration Protocol), EVB can run smoothly.-Provide strict front and rear air ducts in line with the requirements of data center construction.Innovative VSC2.0 (Virtual Switch Cluster) Technology-Support VSC2.0 (Virtual Switch Cluster), which enhances cluster system capacity and port density, simplifies network topology and management.-Real time hot-standby information synchronization between master and standby master to ensure seamless switch over against network failures, enhancing network reliability.-Stacking bandwidth between the VSC switches can be up to 320Gbps, which can solve the bandwidth bottleneck of VSC and deliver customers a real-time non-blocking VSCsystem.-The stacking distance can be up to 80km, it helps customers get rid of distance restriction while designing a reliable VSC system.-Master and slave in VSC works in 1+N redundancy mode, MAD (Multi-active Detect) technology is used to detect and avoid dual master in VSC system when failure happens.Together with real-time hot-standby and seamless switchover it brings customer a moreflexible VSC network.-No need special stacking sub-card, the normal ports can be used for VSC2.0 connecting, which helps customers save investments.•Powerful Service Bearing Capability-By supporting rich L2 switching and L3 routing functions and low latency forwarding, The ZXR10 5960 Series switch can bear lots of service including WLAN, Internet, Voice,Video, Enterprise private network and other data services.-Support Voice VLAN (which means the automatic assignment of dedicated VLAN and QoS strategy to voice equipment), thus enabling the voice traffic to enjoy high priority.-Support L2/L3 multicast, including IGMP snooping, Filtering, Proxy and Fast leave, MVR (Multicast VLAN Registration) and PIM to facilitate the services deployments such asMulti-terminal HD video surveillance and video conferencing. •Comprehensive IPv6 Solution-The ZXR10 5960 Series switch has passed the IPv6 Ready Phase 2 Gold Medal Certification issued by IPv6 Forum.-Support IPv6 unicast routing protocols: IPv6 static routing, RIPng, OSPFv3, IS-ISv6, and BGP4+ and multicast features: MLD v1/v2, MLD snooping, PIMv6.-Support IPv4-to-IPv6 tunnel technologies: IPv6 manual tunnels, 6-to-4 tunnel, ISATAP tunnel and IPv4-compatible automatic tunnel, etc.•Carrier-Grade Reliability and Multi-Dimensional Security-Support dual redundant modular fan and dual modular power supply.-Support Ethernet OAM, including IEEE 802.3ah, 802.1ag, help monitor network real-time operating status and fulfill fast fault detection, fault location.-Support various authentication methods such as 802.1x, Radius, TACACS+. Support CPU overload protection, anti-DDOS, deliver customer a security network.•Easy Maintenance, Saving OPEX-The innovative M-Button delivers instant trouble-shooting by reading indicators on front panel without login via terminal. It helps to solve some common problems immediately.-Zero-touch provisioning, download software and configuration to the switch automatically from the server, Reduce provision process and man power requirement.-Support the SQA (Service Quality Analyzer), detecting the network quality periodically or in real time. In order to provide better quality of service for more valuable services.-Support ALS (automatic laser shutdown), protect people against laser injury when plug out the optical module.Green for More-Front-to-back shoot-through airflow and more air hole design in the front panel improve heat dissipation to reduce power consumption.-Fan speed can automatically adjust by 5 levels in accordance with the temperature inside the switch. It not only saves the power consumption, but also reduces noise andextends life cycle of the fans.-Complying with ROHS, WEEE and ISO14001 certification, No plumbum (Pb) in not only product materials but also the whole processing technic. Meanwhile, use re-cyclesdegradable packing materials, practice green for more.System SpecificationFunction SpecificationApplication Scenarios•TOR in Typical Data Center NetworkThe ZXR10 5960 Series switch works as TOR switch on a typical data center network. The ZXR10 5960 Series switch has high-density 10GE/40GE interfaces to interconnect the 10GE servers and aggregates to the ZXR10 9900 Series switch through 40GE/100GE interfaces. Deploy EBGP and VSC technology to build a non-blocking Layer 3 network, which allows large-scale VM migrations and flexible service deployments.•Aggregation in Carrier NetworkThe ZXR10 5960 Series switch works as high density 10GE aggregation switch which provide40GE as uplink. Through L2/L3 features and ZESR ring protection, the ZXR10 5960 Series switch aggregates the traffic from the access and forward it to the core switch. VSC2.0 technology can realize fast switchover when failure happens.10GE Access for Business CustomerAs the bandwidth increasing fast, more and more business customers need 10GE interface access. The ZXR10 5960 Series switch works as high density 10GE interface switch which provide 40GE as uplink. Through L2/L3 features and ZESR ring protection, the ZXR10 5960 Series switch access the traffic from the business customer and forward it to the aggregation switch.Order Information MainframePower ModuleFan ModuleNO. 55, Hi-tech Road South,ShenZhen,P. R. China Postcode: 518057Web: Tel: +86-755-26770000Fax: +86-755-26771999。

中兴 ZXR10 5009(V10)千兆接入交换机 说明书

中兴 ZXR10 5009(V10)千兆接入交换机 说明书

ZXR10 5009(V1.0)千兆接入交换机用户手册中兴通讯股份有限公司ZXR10 5009(V1.0)千兆接入交换机用户手册资料版本 20060701-R1.0产品版本V1.0策划中兴通讯学院文档开发部编著胡鹏赵志强周继华审核虞成军* * * *中兴通讯股份有限公司地址:深圳市高新技术产业园科技南路中兴通讯大厦邮编:518057技术支持网站:客户支持中心热线:(0755)26770800 800-830-1118传真:(0755)26770801E-mail:doc@* * * *编号:sjzl20061267声明本资料著作权属中兴通讯股份有限公司所有。

未经著作权人书面许可,任何单位或个人不得以任何方式摘录、复制或翻译。

侵权必究。

和是中兴通讯股份有限公司的注册商标。

中兴通讯产品的名称和标志是中兴通讯的专有标志或注册商标。

在本手册中提及的其他产品或公司的名称可能是其各自所有者的商标或商名。

在未经中兴通讯或第三方商标或商名所有者事先书面同意的情况下,本手册不以任何方式授予阅读者任何使用本手册上出现的任何标记的许可或权利。

本产品符合关于环境保护和人身安全方面的设计要求,产品的存放、使用和弃置应遵照产品手册、相关合同或相关国法律、法规的要求进行。

由于产品和技术的不断更新、完善,本资料中的内容可能与实际产品不完全相符,敬请谅解。

如需查询产品的更新情况,请联系当地办事处。

若需了解最新的资料信息,请访问网站FAX :0755-********意见反馈表为提高中兴通讯用户资料的质量,更好地为您服务,希望您在百忙之中提出您的建议和意见,并请传真至:0755-********,或邮寄至:深圳市高新技术产业园科技南路中兴通讯大厦中兴通讯学院文档开发部收,邮编:518057,邮箱:doc@ 。

对于有价值的建议和意见,我们将给予奖励。

资料名称 ZXR10 5009(V1.0)千兆接入交换机用户手册产品版本 V1.0资料版本 20060701-R1.0 您单位安装该设备的时间为了能够及时与您联系,请填写以下有关您的信息姓名单位名称 邮编单位地址 电话E-mail好 较好 一般 较差 差 总体满意工作指导查阅方便 内容正确内容完整结构合理图表说明您对本资料的评价 通俗易懂详细说明 内容结构内容详细内容深度 表达简洁增加图形增加实例增加FAQ您对本资料的改进建议 其 他您对中兴通讯用户资料的其他建议前言手册说明本手册为《ZXR10 5009(V1.0)千兆接入交换机用户手册》,适用于ZXR10 5009千兆接入交换机。

中兴交换机简明配置教程

中兴交换机简明配置教程

中兴交换机简明配置教程1.连接交换机和电源:将交换机与电源连接,并确保交换机正常启动。

2.连接电脑和交换机:使用网线将电脑和交换机的一些端口连接起来。

3. 打开终端程序:在电脑上打开终端程序,如Putty或SecureCRT。

4. 配置终端连接:在终端程序中选择一个连接类型(如SSH或Telnet),并输入交换机的管理IP地址。

5.输入用户名和密码:输入交换机的用户名和密码以登录。

6. 进入特权模式:在命令行界面中输入`enable` 命令进入特权模式。

7.配置交换机的基本信息:输入以下命令设置交换机的基本信息:```configure terminalhostname [交换机设备名]interface vlan managementip address [管理IP地址] [子网掩码]exit```8. 保存配置:在特权模式下输入`write`命令,将当前配置保存到交换机。

9.配置VLAN:输入以下命令配置交换机的VLAN:configure terminalvlan [VLAN ID]name [VLAN 名称]exit```10.配置端口:输入以下命令将端口添加到VLAN:```configure terminalinterface ethernet [端口号]switchport access vlan [VLAN ID]end```11.配置链路聚合:输入以下命令将多个端口聚合为一个逻辑链路:```configure terminalinterface eth-trunk [聚合端口号]mode lacp-statictrunkport [端口号1] to [端口号2]```12.配置静态路由:输入以下命令设置交换机的静态路由:```configure terminalip route-static [目的网络地址] [子网掩码] [下一跳地址]exit```13.配置访问控制列表(ACL):输入以下命令创建和配置ACL:```configure terminalacl number [ACL编号]rule [规则编号] [permit,deny] [源地址] [目的地址] [协议]exit```14. 配置交换机的安全功能:输入以下命令设置交换机的安全功能,如端口安全、DHCP Snooping等:```configure terminalport-security enableip-source-guard enabledhcp-snooping enableexit```15. 保存配置并退出:在特权模式下输入`write`命令,将当前配置保存到交换机,并输入`exit`命令退出交换机。

ZXR10 中兴交换机产品介绍

ZXR10 中兴交换机产品介绍

内部公开▲
主要特征:
3928A
交换容量:48Gbps 大容量全线速多层交换:全线速交换,16K MAC表,
包转发率:14.1Mpps
Max 24*FE(电)+2*GE (光)+ 2*GE(光)/ 2*GE(电)/ 2*FE(光)/
大路由表项 ▪ 端口配置灵活:多种FE、GE端口组合模式
1*GE(光)+1*GE(电)
ZXR10 5224
全千兆路由交换机
型号: 39/39A系列:ZXR10 3952A;3928A/3928A-FI;3906;3928A-PS 32/32A系列:ZXR10 3252A;3228A/3228A-FI;3206 52系列:ZXR10 5252/5228/5228-FI/5224 59系列:5952/5928/5928-FI/5928-PS
顺应时代潮流绿色环保节能减排低成本大带宽低成本大带宽是交换机的基本技术特征将持续发展业务智能化在基本转发平台之上容纳更丰富的业务能力城域网技术延伸满足城域网应用需求并向其他应用场景输出技术中兴282932a39a39e525959e89交换机中兴交换机全系列89595259e39a32a39e2928满足cemetroethernet需求zxr1028系列二层千兆交换机zxr1029系列二层智能交换机zxr1039a32a系列三层智能交换机zxr105952系列全千兆智能交换机zxr1089系列万兆mpls路由交换机超大规模的处理性能超高密度的万兆端口超强的多业务处理能力高可靠性最少的投资成本中兴交换机10年历程中兴交换机系列metroethernet认证二层fe交换机fe上行接入以太网交换机26三层fe交换机ge上行三层智能以太网交换机39二层ge交换机全部ge接口ge上行全千兆以太网交换机50三层ge交换机全部ge接口10ge上行全千兆智能路由交换机59三层ge交换机全部ge接口10ge上行全千兆智能路由交换机52三层fe交换机ge上行三层智能以太网交换机32二层ge交换机全部ge接口ge上行全千兆智能以太网交换机51二层fe交换机ge上行千兆以太网交换机28二层fe交换机ge上行智能以太网交换机29三层路由交换机支持10g接口万兆路由交换机69三层mpls交换机支持10g接口万兆mpls路由交换机89g备注描述系列精简型le标准型sifiber全光口型号fi供电remotepowersupply远供型psstackable支持堆叠型s上联口为光口fu增强型aei备注描述后缀中兴通讯交换机产品命名规则8902890589088912中兴交换机与您共建未来zxr108902890589088912万兆mpls路由交换机性能背板容量

中兴交换机基本配置

中兴交换机基本配置

中兴交换机基本配置1、中兴ZXR10-2826S系列交换机基本配置login:admin //缺省用户名:admin 密码:zhongxingpassword:*********zte>en //缺省ENABLE密码为空password:zte(cfg)#conf tffs //进入文件配置模式zte(cfg-tffs)#ls //显示文件列表kernel.z 1,216,924 bytessnmpboots.v3 35 bytesstartcfg.txt 714 bytesrunning.cfg 198,859 byteszte(cfg-tffs)#remove running.cfg //删除配置文件Sure to remove ? [Yes|No]:yzte(cfg-tffs)#ls //查看系统文件kernel.z 1,216,924 bytessnmpboots.v3 35 bytesstartcfg.txt 714 byteszte(cfg-tffs)#exit //退出zte(cfg)#reboot //重新启动设备Sure to reboot ? [Yes|No]:y上述操作为恢复出厂设置2、设备VLAN配置(802.1Q配置方式)、网管IP地址配置、PVLAN配置、三网合一配置上网vlan 100 电话vlan 2103 IPTV vlan2104login:adminpassword:*********zte>enpassword:zte(cfg)#set vlan 1 del port 1-24 //删除VLAN1中的所有端口,为了防止广播zte(cfg)#set vlan 100enable //激活上网业务VLAN100zte(cfg)#set vlan 100 add port 1 tag //将上联端口以TAG的方式加入到VLAN100中zte(cfg)#set vlan 100 add port 2 untag //将端口2以UNTAG的方式加入到VLAN100中zte(cfg)#set port 2 pvid 100 //设置端口2的PVID为100zte(cfg)#set vlan 2103 enable //激活电话业务VLAN2103zte(cfg)#set vlan 2103 add port 1 tag //将上联端口以TAG的方式加入到VLAN2103中zte(cfg)#set vlan 2103 add port 2 untag //将端口2以UNTAG的方式加入到VLAN2103中zte(cfg)#set port 2 pvid 2103 //设置端口2的PVID为2103zte(cfg)#set vlan 2104 enable //激活IPTV业务VLAN2104zte(cfg)#set vlan 2104 add port 1 tag //将上联端口以TAG的方式加入到VLAN2104中zte(cfg)#set vlan 2104 add port 2 untag //将端口2以UNTAG的方式加入到VLAN2104中zte(cfg)#set port 2 pvid 2104 //设置端口2的PVID为2104zte(cfg)#set vlan 200 add port 1 tagzte(cfg)#set vlan 200 enable //激活网管VLAN200并添加上联端口1zte(cfg)#conf router //进入网管配置模式zte(cfg-router)#set ipport 1 ipaddress 192.168.0.1 255.255.255.0 //配置网管IP 地址zte(cfg-router)#set ipport 1 vlan 200 //绑定网管配置VLAN 1-256zte(cfg-router)#set ipport 1 enable //激活网管虚拟端口zte(cfg-router)#exit //退出zte(cfg)#set pvlan session 1 add promiscuous port 1 //设置PVLAN共享端口1zte(cfg)#set pvlan session 1 add isolated-port 2-10 //设置PVLAN隔离端口2-10 3、端口限速配置、端口速率配置zte(cfg)#set port 2 bandwidth ingress on rate 30000 // 设置端口入向限速3M% Set port 2 bandwidth ingress on rate 30303 kbps succeed!zte(cfg)#set port 2 bandwidth egress on rate 3000 //设置端口出向限速3M% Set port 2 bandwidth egress on rate 3000 kbps succeed!zte(cfg)#set port 2 speed 100zte(cfg)#set port 2 duplex full //设置端口2为强制100M全双工端口zte(cfg)#set port 2 auto enable //设置端口2为自协商端口4、设备开通单端口环路检测zte(cfg)#set loopdetect port 2 enable //设置端口2为单端口环路检测zte(cfg)#set loopdetect port 2 protect enable //打开单端口环路检测保护zte(cfg)#show loopDetectThe block-delay interval of loopback detection is 5 minutes.The send loopdetect packet interval of loopback detection is 15 seconds.PortId Stp Trunk Link Loop Protect VlanId Status Extend------ ---- ----- ----- ----- ------- ------ ------ -------2 No No Up No Yes N/A N/A NoTHU JUL 01 00:17:50 2004 Port : 2 Single Loopback //发现单端口环路5、设备开通IPTV必配zte(cfg)#set igmp snooping enable //IPTV采用的IGMP功能开通zte(cfg)#set igmp snooping add vlan 2104 //在VLAN2104中激活IGMP SNOOPING功能zte(cfg)#set igmp snooping fastleave enable //增加IGMP SNOOPING快速离开功能。

中兴交换机配置流程和配置命令

中兴交换机配置流程和配置命令

中兴交换机配置流程和配置命令一、登录设备1. 首先,通过网线将电脑与中兴交换机的console端口相连。

2. 打开终端仿真软件,如SecureCRT、Putty等。

3.创建一个新的串口会话,选择正确的串口号和波特率,点击“打开”按钮连接设备。

4. 在终端仿真软件上输入交换机的IP地址和登录密码,按Enter键确认登录。

二、创建VLAN1.查看当前交换机上已有的VLAN信息,使用以下命令:show vlan2.创建一个新的VLAN,使用以下命令:vlan vlan-id [vlan-name]vlan-id为VLAN的编号,取值范围为1-4094;vlan-name为VLAN的名称,可选参数。

3.将端口添加到VLAN中,使用以下命令:port vlan vlan-id {port-string , all} [untagged]vlan-id为VLAN的编号;port-string为端口的范围,如1-10;all表示所有端口;untagged可选参数,表示将端口设置为不带Tag的访问端口。

4.在创建完VLAN后,可以使用以下命令查看已配置的VLAN信息:show vlan三、配置端口1.进入接口配置模式,使用以下命令:interface interface-type interface-numberinterface-type为接口类型,如Ethernet、GigabitEthernet等;interface-number为接口编号。

2.配置接口的模式,使用以下命令:[switchport mode {access , trunk}]access表示接口为访问模式,用于连接终端设备;trunk表示接口为Trunk模式,用于连接上层网络设备。

3.配置接口的访问模式下的VLAN信息,使用以下命令:switchport access vlan vlan-idvlan-id为所需的VLAN编号。

4. 配置Trunk模式下的VLAN信息,使用以下命令:switchport trunk vlan {add , remove} vlan-idadd表示添加一个新的VLAN,remove表示移除一个VLAN;vlan-id为VLAN的编号。

中兴交换机简明配置教程汇总

中兴交换机简明配置教程汇总

中兴交换机简明配置教程汇总1. 连接硬件设备:首先,确保中兴交换机已经正确连接到电源和网络设备。

通过网线连接中兴交换机的“Console”端口和计算机的串口。

2. 配置串口连接:打开计算机上的终端模拟器软件,例如SecureCRT或PuTTY。

选择正确的串口,波特率设置为9600,并确保其他设置如数据位、停止位和校验位正确。

3. 进入交换机命令行界面:通过串口连接打开终端模拟器后,点击“Enter”键几次,直到看到交换机的命令行提示符。

4. 进入特权模式:在命令行提示符下,输入“enable”命令,然后输入密码(如果已设置),以进入特权模式。

5. 进入全局配置模式:输入“configure terminal”命令,进入全局配置模式。

在全局配置模式下,可以进行交换机的各种配置。

6. 配置主机名:输入“hostname <名称>”命令,将中兴交换机的主机名设置为指定的名称。

7. 配置IP地址:输入“interface vlanif <编号>”命令,进入VLAN接口配置模式。

然后输入“ip address <IP地址> <子网掩码>”命令,设置中兴交换机的IP地址和子网掩码。

8. 配置默认网关:输入“ip default-gateway <默认网关IP地址>”命令,设置中兴交换机的默认网关。

9. 配置SSH远程管理:输入“ssh server enable”命令,启用中兴交换机的SSH服务器功能。

然后输入“user-interface vty 0 15”命令,进入虚拟终端配置模式。

最后输入“authentication-mode aaa”命令,指定使用AAA方式进行身份验证。

10. 配置Telnet远程管理(可选):输入“telnet server enable”命令,启用中兴交换机的Telnet服务器功能。

然后输入“user-interface vty 0 15”命令,进入虚拟终端配置模式。

中兴AS5835-54T交换机快速安装指南说明书

中兴AS5835-54T交换机快速安装指南说明书

Quick Start GuideAttach the Brackets1.Attach each of the front- and rear-post brackets to the switchusing four of the included bracket e the screws and cage/clip nuts supplied with the rack tosecure the switch in the rack.Adjust Rear-Post Bracket Ears1.Lock the position of the rear-post bracket ears using the includedposition-locking screws.You can adjust the rear-post bracket ears to fit different rack depths from 56 cm to 75 cm.Ground the Switch1.Ensure the rack is properly grounded and in compliance withETSI ETS 300 253. Verify that there is a good electrical connection to the grounding point on the rack (no paint or isolating surface treatment).2.Attach the grounding wire (#14 AWG) to the grounding pointon the switch rear panel. Then connect the other end of the wire to rack ground.Warning: For a safe and reliable installation, use onlythe accessories and screws provided with the AS5835-54T . Use of other accessories and screws could result in damage to the unit. Any damages incurred by using unapproved accessories are not covered by the warranty.Avertissement: Pour une installation sûre et fiable, utilisez uniquement les accessoires et les vis fournies avec le AS5835-54T . L ’utilisation d’autres accessoires et vis pourrait endommager l’appareil. Les dommages causés par l’utilisation d’accessoires non approuvés ne sont pas couverts par la garantie.Caution: The switch includes plug-in power supply (PSU) and fan tray modules that are installed into its chassis. All installed modules must have a matching airflow direction. That is, if the installed power modules have a front-to-back (F2B) airflow direction, all the installed fan tray modules must also have a F2B airflow direction.Attention: Le commutateur comprend des modules d’alimentation et de bac de ventilateurs installés sur son châssis. Tous les modules installés doivent avoir unedirection de circulation d’air correspondante. C’est-à-dire que tous les modules doivent avoir la même direction de circulation d’air : avant vers arrière (F2B), ou arrière vers avant (B2F).Note: The switch has the Open Network InstallEnvironment (ONIE) software installer pre-loaded on the switch, but no switch software image. Information about compatible switch software can be found at.1112Caution: Installing the switch in a rack requires twopeople. One person should position the switch in the rack, while the other person secures it using the rack screws.Attention: Deux personnes sont nécessaires pour installerun commutateur dans un bâti : La première personne va positionner le commutateur dans le bâti, la seconde va lefixer avec des vis de montage.2131254-Port 10G/100G Ethernet SwitchAS5835-54T1.54-Port 10G/100G Ethernet Switch AS5835-54T2.Rack mounting kit—2 front-post brackets, 2 rear-postbrackets, 20 screws, and 2 ear-locking screws 3.Power cord (included with AC PSUs only)4.Ground wire (included with DC PSUs only)5.Console cable—RJ-45 to D-Sub6.DC power connector (included with 48 VDC PSU only)7.Documentation—Quick Start Guide (this document) andSafety and Regulatory Information1Package Contents234576Connect Power1.Install one or two AC or DC PSUs in the switch.The switch supports up to two PSUs that must have the same matching airflow direction as the installed fan tray.2.Connect an external AC or DC power source to the PSUs.1.DC Return2.-36 –-75 VDC 3.GroundVerify Switch Operation1.Verify basic switch operation by checking the system LEDs.When operating normally, the PSU1/PSU2, OS Diag, and Fan LEDs should all be on green.Perform Initial System Boot1.If the network operating system (NOS) installer is located on anetwork server, first connect the RJ-45 Management (Mgmt) port to the network using 100-ohm Category 5, 5e or better twisted-pair cable. (Not required if the NOS installer is located on attached storage.)2.Boot the switch. Wait for the ONIE software to locate andexecute the NOS installer, and then wait for the installer to load the NOS software image.Subsequent switch boots will bypass ONIE and directly run the NOS software.Connect Network Cables1.For RJ-45 ports, use 100-ohm Category 6, 6a, or 7 twisted-paircable for 10GBASE-T connections, or Category 5e or better cable for 1000BASE-T connections. 2.Connect DAC cables to the QSFP28 slots. Or first installQSFP28 transceivers in the slots and then connect fiber optic cabling to the transceiver ports. 3.As connections are made, check the port status LEDs to be surethe links are valid.For the RJ-45 ports:■Green — 10 Gbps mode ■Amber — 1 Gbps modeEach QSFP28 port has four LEDs that indicate valid links in the following modes:■ 1 LED Green — 100 Gbps mode ■ 1 LED Blue — 40 Gbps mode■1-4 LEDs Amber — 25 Gbps breakout mode (four lanes)■1-4 LEDs Purple — 10 Gbps breakout mode (four lanes)Caution: The earth connection must not be removed unless all supply connections have been disconnected.Attention: Le raccordement à la terre ne doit pas être retiré sauf si toutes les connexions d’alimentation ont été débranchées.Caution: Use a UL/IEC/EN 60950-1 certified powersupply to connect to a DC converter, and a #14 AWG wire (for -36 VDC to -75 VDC PSU) to connect to a DC PSU.Attention: Utilisez une alimentation certifiée UL/IEC/EN 60950-1 pour le connecter à un convertisseur CC et un câble AWG #14 (pour -36 VDC à -75 VDC) pour vous connecter à une alimentation CC.42121351Note: Refer to the network operating system (NOS) installer and NOS documentation for details on software options and set up for ONIE.67123Switch ChassisSize (WxDxH)442.5 x 473.3 x 43.95 mm (17.42 x 18.63 x 1.73 in) Weight9.59 kg (21.14 lb), with two installed PSUsT emperature Operating: 0° C to 40° C (32° F to 104° F)Storage: -40° C to 70° C (-40° F to 158° F) Humidity Operating: 5% to 95% (non-condensing)PowerConsumption323 Watts maximumAC PSUPower Rating100–240 VAC, 50–60 Hz, 400 WattsAC Input100-240 VAC, 50-60 Hz, 6–3 A100–127 VAC, 47–63 Hz, 6.0 A200–240 VAC, 47–63 Hz, 3.0 A48 VDC PSUPower Rating48 VDC, 400 WattsDC Input-36 – -75 VDC, 14–7 A Regulatory CompliancesEmissions EN 55032:2015+AC:2016, Class AEN 61000-3-2:2014, Class AEN 61000-3-3:2013FCC Class AVCCI Class ACCC GB 9254-2008, Class ABSMI Class A, CNS 13438Immunity EN 55024:2010+A1:2015IEC 61000-4-2/3/4/5/6/8/11Safety UL (CSA 22.2 No 60950-1 & UL60950-1)(CSA 22.2 No 62368-1 & UL62368-1)CB (IEC/EN60950-1)(IEC/EN62368-1)CCC GB4943.1-2011BSMI, CNS 14336-1T aiwan RoHS CNS 15663Hardware Specifications快速入门指南安装支架1.使用四个随附的支架螺丝将各个前柱和后柱支架安装到交换机。

中兴交换机ZXJ10功能单元及单板介绍分析

中兴交换机ZXJ10功能单元及单板介绍分析

中兴交换机ZXJ10功能单元及单板介绍分析中兴交换机ZXJ10是一种高性能、高可靠性的交换机,可广泛应用于各种场合,提供灵活的数据传输和通信服务。

为了满足不同需求,ZXJ10采用模块化设计,由多个功能单元组成。

下面将介绍一些常见的功能单元及单板。

1. 交换单元:交换单元是ZXJ10交换机的核心组件,负责数据包的路由与转发。

它采用高性能的交换芯片和专用硬件,能够实现高速数据包的处理和转发。

交换单元可提供多个端口,支持不同速率的数据传输,如10Gbps、40Gbps、100Gbps等。

2. 接入单元:接入单元是ZXJ10交换机的接口模块,提供各种接口和连接选项。

接入单元可以支持不同的接入方式,如以太网接口、光纤接口、SDH接口等,满足不同网络的接入需求。

接入单元还可以提供不同速率的接口,如10Mbps、100Mbps、1Gbps等。

3.管理单元:管理单元是ZXJ10交换机的管理控制模块,负责交换机的配置、监控和管理功能。

管理单元可以通过WEB界面、命令行界面等方式进行配置管理,实现对交换机的各项参数进行设置和调整。

管理单元还可以实现系统性能监控、故障诊断和日志记录等功能,帮助用户了解交换机的运行状态和故障信息。

4.供电单元:供电单元是ZXJ10交换机的供电模块,负责为交换机及其各个功能单元提供稳定可靠的电源。

供电单元通常支持交流电和直流电两种供电方式,具有电压和温度的监测和保护功能,确保交换机的正常运行和安全性。

5.DSP单元:DSP单元是ZXJ10交换机的数字信号处理模块,负责实时处理音频和视频数据。

DSP单元采用高性能的数字信号处理芯片,能够对语音信号和视频信号进行编解码、压缩和处理,实现高质量的数据传输和通信。

以上是中兴交换机ZXJ10常见的功能单元及单板介绍。

这些功能单元和模块相互配合,共同构成了一套完整的交换机系统,并具备高性能、高可靠性和灵活性的特点。

用户可以根据自己的需求选择不同的单元和模块,组装成适合自己的交换机系统,满足不同场合的通信需求。

交换机配置指导(中兴)

交换机配置指导(中兴)

交换机配置指导(中兴)
1、高性能和可靠性:中兴交换机采用先进的硬件设计和优化的交换技术,提供高速、高可靠性的数据转发和处理能力,适用于大规模的网络环境。

2、强大的安全性:中兴交换机支持多种安全功能,如端口安全、访问控制列表(ACL)、VLAN划分、802.1X认证等,能够有效保护网络免受未授权访问和网络攻击。

3、灵活的网络虚拟化:中兴交换机支持VLAN、VXLAN、VRF等虚拟化技术,将物理网络划分为多个逻辑网络,实现网络资源的灵活分配和隔离。

4、丰富的QoS支持:中兴交换机提供灵活的流量控制和优先级处理功能,支持流量限速、流量分类和优先级调度等,确保重要数据流的带宽和服务质量。

5、简化的管理和运维:中兴交换机提供直观易用的Web界面和命令行接口(CLI),支持远程管理和监控,同时与网络管理系统(NMS)集成,实现集中化的配置和监控。

6、高度可扩展:中兴交换机支持灵活的模块化设计,根据需要选择不同的接口类型和扩展模块,满足不同规模和需求的网络扩展和升级。

7、多层次的网络设计支持:中兴交换机提供多层次的网络设计支持,包括核心交换、汇聚交换和接入交换等,能够适应不同部署场景和网络架构的需求。

8、综合的性能监控和故障诊断:中兴交换机提供实时性能监控和故障诊断功能,及时发现和解决网络故障,提高网络的可用性和稳定性。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

ZTE(中兴)交换机配置常用命令汇总(2009-03-22 16:22:42)
标签:杂谈
ZTE交换机配置常用命令汇总(摘自网络)
个人心得:命令的使用要注意各种用户模式。

配成普通交换机:把2-24端口归到VLAN1下,2-24端口如果互相隔离,可以用PVLAN删除隔离端口即可。

2852s和2826s配置:
创建VLAN命令如下:
set vlan 10 enable ///创建vlan
set vlan 10 add port 1-24 untag ///在创建的vlan内添加用户端口set vlan 10 add port 25 tag ///把级联端口添加到vlan10中,需打tag标签,即为trunk端口。

set port 1-24 pvid 10 ///把添加到vlan10的用户端口,pvid 至vlan10中。

交换机用户端口必须在所添加的vlan中做
此项命令。

(默认的pvid为vlan10)
删除vlan命令如下:
set vlan 10 delete port 1-24 ///删除用户端口
set vlan 10 delete port 25 ///删除级联端口
set vlan 10 disable ///删除vlan
set port 1-24 pvid 1 ///恢复默认设置,该项命令必须添加,不然还会在show running-config信息中显示
set port 1-24 pvid 10的信息,会导致vlan用户使用不正常。

ENABLE密码配置:
zte>enable //进入全局配置模式
password:***** //输入进入全局配置模式的密码,缺省没有密码
zte(cfg)#adminpass zxr10 //配置进入全局配置模式的密码为zxr10
TELNET 用户名密码配置(为了便于对设备的维护,有时需要修改登录用户名或密码,配置如下:)
zte(cfg)#create user zxr10 //创建名为zxr10的用户
zte(cfg)#loginpass zxr10 //设置登录密码为zxr10
zte(cfg)#show user //显示telnet登录用户信息和当前用户名
配置三层管理或业务地址:
config router ///进入config router模式
set ipport 0 ipaddress 10.20.20.1 255.255.255.0 ///设置三层接口ip
地址及掩码
set ipport 0 vlan 10 ///三层端口绑定vlan set ipport 0 enable ///启用三层端口
iproute 0.0.0.0 0.0.0.0 10.20.20.1 ///设置默认路由指向网关
T40G和5228交换机配置:
批量创建vlan方式:
zxr10#vlan database
zxr10(vlan)#vlan 10-20
这样子10-20号连续的vlan就创建起来了,适合批量创建vlan。

在vlan中添加用户端口:
zxr10(config)vlan 10 ///进入vlan10
zxr10(config-vlan)switchport pvid fei_1/1-24 ///在vlan10中添加1-24号端口为用户端口,此时默认模式已经为access模式。

配置trunk级联端口(全局模式下):
interface fei_1/1 ///进入级联端口的接口模式
switchport mode trunk ///设置端口模式为trunk switchport trunk vlan 10 ///级联端口与vlan绑定
三层接口地址配置:
interface vlan 10 ///进入三层vlan接口模式ip address 10.20.20.1 255.255.255.0 ///配置三层ip地址
28系列交换机pvlan配置:
set pvlan session 1 add isolated-port 1-24 ////添加隔离端口
set pvlan session 1 add promiscuous port 25 ////添加共享端口
32系列交换机pvlan配置:
vlan private-map session-id 1 isolate fei_1/1-24 promis gei_3/1 ////添加隔离端口和共享端口
SNMP:
2826s:
create community zte private
create view zteview include 1.3.6.1
set community zte view zteview
set host 192.168.200.100 trap v2c zte
set trap coldstart enable
set trap warmstart enable
set trap linkup enable
set trap linkdown enable
set trap authenticationfail enable
set trap topologyChange enable
set trap memberUpDown enable
t40g:
snmp-server community zte view AllView rw
snmp-server host 192.168.200.100 trap version 2c zte udp-port 162 snmp-server enable trap。

相关文档
最新文档