PdMTC-16001_09April2016_ESA_Bearing Fault-TJZS
SIRIUS 3RU2 型号电机保护过压保护器说明书
product brand name product designation product type designation
General technical data Size of overload relay Size of contactor can be combined company-specific ● Power loss [W] for rated value of the current at AC in hot operating state ● power loss [W] for rated value of the current at AC in hot operating state per pole insulation voltage with degree of pollution 3 at AC rated value surge voltage resistance rated value maximum permissible voltage for safe isolation ● in networks with grounded star point between auxiliary and auxiliary circuit ● in networks with grounded star point between auxiliary and auxiliary circuit ● in networks with grounded star point between main and auxiliary circuit
● Operating current of auxiliary contacts at AC-15 at 110 V ● Operating current of auxiliary contacts at AC-15 at 120 V ● Operating current of auxiliary contacts at AC-15 at 125 V ● Operating current of auxiliary contacts at AC-15 at 230 V ● operating current of auxiliary contacts at AC-15 at 400 V ● operating current of auxiliary contacts at DC-13 at 24 V ● Operating current of auxiliary contacts at DC-13 at 60 V ● Operating current of auxiliary contacts at DC-13 at 110 V ● operating current of auxiliary contacts at DC-13 at 125 V ● Operating current of auxiliary contacts at DC-13 at 220 V Contact rating of auxiliary contacts according to UL
JUMO 402050压力传感器用户指南说明书
Data Sheet 402050Page 1/7JUMO dTRANS p31Pressure transmitter for elevated media temperaturesGeneral applicationPressure transmitters are used for measuring the relative (gauge) and absolute pressures in li-quids and gases. The pressure transmitter operates on the piezo-resistive measuring principle.The pressure is converted into an electrical signal.Type 402050Technical dataReference conditions To DIN 16086 and IEC 770/5.3Ranges See order details Overload limit All ranges 3× full scale Bursting pressureAll ranges 4× full scaleParts in contact with medium Standard: stainless steel 316Ti/316LOutput0to 20mA, two-wire (output 402)Burden ≤(U B -12V)÷0.02A 4to 20mA, two-wire (output 405)Burden ≤(U B -10V)÷0.02A 4to 20mA, three-wire (output 406)Burden ≤(U B -12V)÷0.02A 0,5to 4,5V, three-wire (output 412)Burden ≥50k Ω0to 10V, three-wire (output 415)Burden ≥10k Ω1to 5V, three-wire (output 418)Burden ≥10k Ω1to 6V, three-wire (output 420)Burden ≥10k ΩBurden error <0.5% max.Zero offset ≤0.3% MSP (measuring span)Thermal hysteresis ≤±0.5% MSP (within compensated temperature range)Ambient temperature error Within range 0to 100°C (compensated temperature range)Zero≤0.02%/K typical, ≤0.04%/K max.Measuring span≤0.02%/K typical, ≤0.04%/K max.Deviation from characteristic ≤0.5% MSP (limit point setting)For basic type extension 023≤0.2% MSP (limit point setting)Hysteresis ≤0.1% MSPData Sheet 402050Page 2/7Repeatability≤0.05% MSPResponse timeCurrent output0to20mA, two-wire (output 402)≤3msec max.4to20mA, two-wire (output 405)≤3msec max.4to20mA, three-wire (output 406)≤3msec max.Voltage output0,5to4,5V, three-wire (output 412)≤10msec max.0to10V, three-wire (output 415)≤10msec max.1to5V, three-wire (output 418)≤10msec max.1to6V, three-wire (output 420)≤10msec max.Stability over 1 year≤0.5% MSPVoltage supply a0to20mA, two-wire (output 402)DC11,5to30V4to20mA, two-wire (output 405)DC10to30V4to20mA, three-wire (output 406)DC11,5to30V0,5to4,5V, three-wire (output 412)DC5V0to10V, three-wire (output 415)DC11,5to30V1to5V, three-wire (output 418)DC10to30V1to6V, three-wire (output 420)DC10to30VMax. current drawn Approx. 25mAVoltage supply influence≤0.02%/V, nominal voltage supply DC24Vratiometric with voltage supply DC5V (±0.5V)-20to+125︒CPermissible ambient temperature(max. housing temperature)Storage temperature-40to+125︒CPermissible temperature of medium-30to+200°CElectromagnet compatibility EN 61326Interference emission Class BInterference immunity Industrial requirementsMechanical shock b100g/1msecMechanical vibration c Max. 20g at 15to2000HzProtection type dTerminal box (electrical connection 12)IP67Round plug M12×1IP67(electrical connection 36)Cable socket (electrical connection 61)IP65 (connecting cable diameter min. 5mm, max. 7mm)Housing Stainless steel, mat. ref. 1.4301Polycarbonate GFPressure connection See order details; other connections on requestElectrical connection See order detailsTerminal box (electrical connection 12)4-pole, PVC cable, length 2m, other length on request4-poleRound plug M12×1(electrical connection 36)Cable socket (electrical connection 61)To DIN EN 175301-803, conductor cross-section upt ot max. 1.5mm2Nominal position AnyWeight200ga Ripple: The voltage spikes must not go above or below the values specified for the supply.b DIN IEC 68-2-27c DIN IEC 68-2-6d EN 60529Data Sheet 402050Page 3/7Connection diagramThe connection diagram in the data sheet provides preliminary information about the connection options. For the electrical connection only use the installation instructions or the operating manual. The knowledge and the correct technical execution of the safety information/instructions contained in these documents are mandatory for installation, electrical connection, startup, and for safety during operation.ConnectionTerminal assignment 123661Fixed cableRound plug M12×1Cable socket Voltage supply DC 10to 30V DC 11,5to 30V DC 5V White Grey1+3- 1 L+2 L-Output 1to 6V 0to 10V 0,5to 4,5VGrey Yellow 3-4+ 2 -3 +Output 4to 20mA, two-wireWhite Grey 1+3- 1 +2 -Proportional current 4to 20mA in voltage supplyOutput 0(4)to 20mA, three-wireGrey Yellow3-4+2 -3 +Protection conductor Screen Black2Caution:Earth device(pressure connection and/oror screen)!Data Sheet 402050Page 4/7DimensionsElectrical connection Process conntection, front-flushBO-ringBO-ringData Sheet 402050Page 5/7Process connection DNØD1ØD2ØD3ØD4L1L2ProcessconnectionDNDIN 32676DN(Zoll)Nominal SizeISO 2852ØD1ØD26032036.530RD44×1/6541321612201227.534 604254435RD52×1/663151512.7605325041RD58×1/67017.2606405648RD65×1/67821.36075068.561RD78×1/6921622613251“2543.550.532 1.5“33.74038616502“4056.56451see data sheet 409711Data Sheet 402050Page 6/7Order details(1)Basic type402050/000JUMO dTRANS p31 – Pressure transmitter for elevated media temperatures402050/023JUMO dTRANS p31 – Pressure transmitter for elevated media temperatures, reduced deviation from characteristic a 402050/999JUMO dTRANS p31 – Pressure transmitter for elevated media temperatures, special version(2)Input4540to1bar relative pressure4550to1,6bar relative pressure4560to2,5bar relative pressure4570to4bar relative pressure4580to6bar relative pressure4590to10bar relative pressure4600to16bar relative pressure4610to25bar relative pressure4620to40bar relative pressure4630to60bar relative pressure478-1to0bar relative pressure479-1to+0,6bar relative pressure480-1to+1,5bar relative pressure481-1to+3bar relative pressure482-1to+5bar relative pressure483-1to+9bar relative pressure484-1to+15bar relative pressure485-1to+24bar relative pressure4880to1bar absolute pressure4890to1,6bar absolute pressure4900to2,5bar absolute pressure4910to4 bar absolute pressure4920to6bar absolute pressure4930to10bar absolute pressure4940to16bar absolute pressure4950to25bar absolute pressure998Sondermessbereich absolute pressure999Sondermessbereich relative pressure(3)Output4020to20mA, three-wire4054to20mA, two-wire4064to20mA, three-wire4120,5to4,5V, three-wire4150to10V, three-wire4181to5V, three-wire4201to6V, three-wire(4)Process connection550Aseptic to DIN 11864-1A, DN20551Aseptic to DIN 11864-1A, DN25552Aseptic to DIN 11864-1A, DN32553Aseptic to DIN 11864-1A, DN40554Aseptic to DIN 11864-1A, DN50570G11/2 front-flush, DIN EN ISO 228-1571G3/4 front-flush, DIN EN ISO 228-1575G3/4 front-flush with double sealData Sheet 402050Page 7/7576G1 with double seal584SMS, DN1585SMS, DN11/2586SMS, DN2603Taper socket with grooved union nut DN20, to DIN 11851 (dairy pipe fitting)604Taper socket with grooved union nut DN25, to DIN 11851 (dairy pipe fitting)605Taper socket with grooved union nut DN32, to DIN 11851 (dairy pipe fitting)606Taper socket with grooved union nut DN40, to DIN 11851 (dairy pipe fitting)607Taper socket with grooved union nut DN50, to DIN 11851 (dairy pipe fitting)612Clamping socket (clamp) DN10, DN15, DN20b to DIN 32676613Clamping socket (clamp) DN25, DN40b to DIN 32676616Clamping socket (clamp) DN50 (2“)b to DIN 32676619Clamping socket (clamp) DN15 (3/4“)b to DIN 32676623Small flange DN25, to DIN 28403652Tank connection with grooved union nut DN25661Clamping flange (DRD), Ø65mm684VARIVENT® connection, DN15/10685VARIVENT® connection, DN32/25686VARIVENT® connection, DN50/40997JUMO-PEKA with EHEDG certification c(5)Process connection material20CrNi (stainless steel)(6)Electrical connection12Terminal box, screened, 2m (other length on request)36Round plug M12×161Cable socket DIN EN 175301-803, form A(7)Extra codes000None452Parts in contact with the medium are electropolished, surface roughness Ra 0.8µm631Improved moisture and vibration protectiona A reduced deviation from characteristic is not available for ± ranges; it is available only in conjunction with 4to20mA, two-wire (output 405).b These process connections are only suitable with measuring spans up to 25bar.c Suitable process connection adapter, see data sheet 409711(1)(2)(3)(4)(5)(6)(7) Order code-----/Order example402050/000-459-405-571-20-61/000AccessoriesArticle Part no.Cable box (straight) with control cable, screen, 4-pole, 5m PVC cable, pressure compensation00512341。
ICP DAS I-7022 2通道12位模拟输出数字输出DAQ模块快速入门指南说明书
I-70222 Channel 12-bit Analog Output CurrentData Acquisition ModuleQuick Start GuideProduct Website:/i_7022.html/dcon_utility_pro.html1. IntroductionI-7022 provides cost-effective protection and conditioning for a wide range of valuable industrial control signals and systems. The DCON utility can help users to configure and test I-7022 analog output modules. Plenty of library functions and demo programs are provided to let users develop programs easily under Windows, Linux and DOS operating systems Users may mount the modules on a DIN rail, panel or wall. Modules have ascrew-terminal block to connect to the signals. I-7022 comes with FREE EZ Data Logger Software.2. Terminal Assignment3. Block/ Wiring Diagram4. Default SettingsDefault setting for I-7021, I-7021P, I-7022 and I-7024 : Address : 01Analog Output Type : 0 to +10V Baudrate : 9600 bpsChecksum disable, change immediate, engineer unit format I-7021, I-7021P, I-7022 jumper setting : internal power.5. ConfigurationTo install the module, follow the steps below:1. Connect the analog output.2. Connect the module to the RS-485 network using the DATA+ and DATA- terminals. If the host is only equipped with an RS-232 interface, then an RS-232 to RS-485 converter will be required.3. Connect the module to the power supply using the +Vs and GND terminals. Note that the voltage supplied should be in the range of +10 to +30V DC.4. Open DCON utility proclick on COM port(first icon).It can select multi-options such as Baud Rate, Protocol, Checksum, and Format to search module. The default settings for the module can be found in Section 3. Click OK after selecting the COM port setting.5. DCON utility pro will search for the selected COM port according the setting previously set. DCON Utility Pro supports DCON and Modbus protocol for all ICPDAS and the others modules.6. Configuration I/O module setting on PC7. For I-7000 modules, DCON utility pro terminal can send command to the module. See user manual Sections 2 for details command.Configure the module: sending the %AANNTTCCFF command. See user manual Section 2 for details.Read data from the input channels: send either the #AA or #AAN command to the module.8. If user doesn’t know command, user can select Address and ID, it will show some refer commands as below. User can select necessary command to test or debug modules.。
西储大学轴承数据
DE - drive end accelerometer data 驱动端加速度数据FE - fan end accelerometer data 风扇端加速度数据BA - base accelerometer data 基座加速度数据(正常)time - time series data 时间序列数据RPM- rpm during testing 每秒钟多少转,除以60为旋转频率该实验台如图所示,包括一个2 马力(1.5KW)的电动机,一个扭矩传感器/ 译码器,一个功率测试计,还有电子控制器(图中没显示) 。
待检测的轴承支撑着电动机的转轴,驱动端轴承为SKF6205,风扇端轴承为SKF6203,下表中分别列出了两种轴承的几何尺寸和各部件的故障频率。
轴承用电火花加工单点损伤,损伤直径分为(0.007英寸=7 mils =0.177 8 mm,0.014英寸=14 mils =0.355 6 mm ,0.021英寸=21 mils =0.533 4 mm,0.028英寸=28 mils =1.016 mm,0.04英寸=40 mils =1.016 mm。
(1英寸=25.4mm)其中,轴承外圈的损伤点在时钟:3 点钟、6 点钟、12 点钟3 个不同位置进行设置。
电动机风扇端和驱动端的轴承座上方各放置一个加速度传感器用来采集故障轴承的振动加速度信号。
振动信号由16 通道数据记录仪采集得到,采样频率为12 kHz,驱动端轴承故障还包含采样频率为48 kHz 的数据。
功率和转速通过扭矩传感器/ 译码器测得。
数据收集的,正常的轴承单点驱动器和风扇月底结束的缺陷。
数据收集在12,000次/秒和48,000次/驱动器端轴承实验秒。
所有球迷端轴承数据收集12,000次/秒。
数据文件在Matlab格式。
每个文件包含风扇和驱动器结束振动数据,以及电机转速。
对于所有文件,在变量名显示下列项目:德- 加速度计数据驱动结束远东- 风扇结束加速度数据广管局- 加速基础数据时间- 时间序列数据RPM的转速在测试1、轴承规格和故障频率:轴承型号:Drive end bearing: 6205-2RS JEM SKF,深沟球轴承(deep groove ball bearing);其中:2RS 是双面密封,JEM无意义,SKF(Svenska Kullager-Fabriken)是斯凯孚公司(总部所在地:瑞典哥德堡),NTN是日本公司。
T-BERD 2207用户指南说明书
198150-15217-01Rev. DT-BERD 2207USER’S GUIDEThis manual applies to all T-BERD 2207 software incorporating software level 3.x.JANUARY 2000Copyright ©1998 TTC®USA 1-800-638-2049 • +1-301-353-1550 • FAX +1-301-353-0234Canada 1-888-689-2165 • +1-905-507-4117 • FAX +1-905-507-4126SECTION 9 - SpecificationsGeneral SpecificationsSECTION 9 SPECIFICATIONS9.1GENERAL SPECIFICATIONS9.1.1Physical Characteristics:Height:7.5" (19 cm)Width:11.5" (29.2 cm)Depth: 2.25" (5.7 cm)Weight: 4.25 lb. (1.93 kg.)9.1.2Environmental Characteristics:Temperature:Operating:32°F to 122°F (0°C to +50°C)Non-Operating:-40°F to 167°F (-40°C to +75°C)Humidity:10% to 90% Relative Humidity, non-condensing9.1.3Electrical Characteristics:Battery Type:10.8 V Nickel-Metal Hydride (NiMH)Operating Time:Typically, up to three hours of continuous operation on a full chargeRecharging Period:Maximum of two hours from full dischargeAC Adaptor:120VAC to 18 VDC 1.2A9.2DS1 SPECIFICATIONS9.2.1Input Specifications9.2.1.1RX JackConnector Type:Bantam jackFrequency:1,544,000 Hz ±5000 HzUser’s Guide T-BERD 22079-1SECTION 9 - SpecificationsDS1 SpecificationsImpedanceBRIDGE:1000 ohms minimumTERM:100 ohms ±5%DSX-MON:100 ohms ±5%RangeBRIDGE:+6 to -35.0 dBdsxTERM:+6 to -35.0 dBdsxDSX-MON:+6 to -24.0 dBdsx of resistive los9.2.1.2Loop Codes Detection CriteriaIn-Band:At least 177 error-free bits of the selected repetitive pattern must be received(loop up or loop down).Out-of-Band:Datalink monitored every 125 ms for loop codes (loop up and loop down).9.2.1.3Pattern Synchronization Detection CriteriaFixed Patterns:30 consecutive error-free bitsPseudo-random:30 + n consecutive error-free bits for a pattern length of 2^n-19.2.2Output Specifications9.2.2.1TX JackConnector Type:Bantam jackLBO Level:Line build-out of 0, -7.5, -15.0, and -22.5 dB of cable loss at 772 HzLBO Tolerance:±2 dB at 772 kHzTiming:±7 ppm internal or recoveredLine Codes:AMI or B8ZSError Insert Type:Logic, BP V, or FramePulse Shape:With output terminated in 100 ohms resistive load and 0 dB line build-outselected, the T-BERD 2207 meets ITU-T Recommendation G.703; AT&TPublications CB113, CB119, CB132, CB143, and PUB62508; and AT&TPUB62411 pulse shape specifications.9-2T-BERD 2207User’s GuideSECTION 9 - SpecificationsDS1 Specifications 9.2.2.2Transmitted Loop CodesIn-BandCSU:Loop-up: 10000; Loop-down: 100Facility 1:Loop-up: 1100; Loop-down: 1110Facility 2:Loop-up: 11000; Loop-down: 11100Facility 3:Loop-up: 100000; Loop-down: 100Out-of-BandLine:Loop up: 1111 1111 0111 0000Loop down: 1111 1111 0001 1100Payload:Loop up: 1111 1111 0010 1000Loop down: 1111 1111 0100 1100Network:Loop up: 1111 1111 0100 1000Loop down: 1111 1111 0010 01009.2.3Measurement SpecificationsFrequencyRange:1,544,000 ±5000 HzAccuracy:± 7 ppmResolution: 1 HzReceived LevelRange:+6 dBdsx to -40 dBdsxAccuracy:±1.0 dB between +6 and -10 dBdsx±2.0 dB between -10 and -20 dBdsx±3.0 dB between -20 and -40 dBdsxResolution:0.1 dBVp-p Range:60 mV to 12.0 VVp-p Resolution:0.05 VSimplex CurrentRange:10 mA to 180 mAccuracy:±5%Resolution: 1 mASimplex path:13.2 ohms (nominal)User’s Guide T-BERD 22079-3SECTION 9 - SpecificationsDS1 Specifications9.2.4Alarm CriteriaSignal Loss:175 ±75 consecutive zerosFrame LossD4: 2 out of 5 Ft bits in errorESF: 2 out of 5 frame bits in errorSLC-96: 2 out of 5 Ft bits in errorPattern Loss:100 errors detected in 1000 or fewer bitsOnes DensityQRSS:Alarm is suppressed.Other Patterns:Received data contains less than n ones in 8(n+1) bits, where n=1 to 23.Excess ZeroAMI:16 or more consecutive zerosB8ZS:8 or more consecutive zerosYellow AlarmD4:Bit 2 is a 0 for 255 consecutive channels.ESF:256 bits ±16 bits of a repetitive (1111 1111 0000 0000) pattern received inthe 4 kb/s datalink.SLC-96:Bit 2 is a 0 for 255 consecutive channels.AIS:Unframed T1 signal has 2048 consecutive ones.Low Battery:Battery has less than 25% energy remaining.9-4T-BERD 2207User’s GuideSECTION 9 - Specifications DS3 Option SpecificationsUser’s Guide T-BERD 22079-59.3DS3 OPTION SPECIFICATIONS9.3.1DS3 Specifications9.3.1.1Framing Formats9.3.1.2Patterns9.3.1.3Line Coding•B3ZS9.3.1.4Connectors•WECO 560A jack9.3.1.5Receiver (Single)Frequency:44,736 Mb/s ±300ppmLevel:HIGH: Accepts Nominal 1.2 Vp, 0 ft. of cable from High sourceDSX: Accepts Nominal 0.6 Vp, 450 ft. of c able from High source or monitor LOW: Accepts Nominal 0.3 Vp, 900 ft. of cable from High source9.3.1.6Transmitter (Single)Frequency:44,736 Mb/s ±20ppmPulse:HIGH: Nominal 1.2 Vp (Signal meets ANSI specification T1.102-1993 and ITU-TG.703 when subjected to 450 feet of cable loss.)•Auto• Muxed M13•Unframed • C-bit•M13• Muxed C-bit•1111• 215-1•1100 (Idle)• 220-1•1010 (AIS)• 223-1•1010• User (3 to 24 bit programmable)SECTION 9 - SpecificationsDS3 Option SpecificationsDSX: Nominal 0.91 Vp (Signal meets ANSI specification T1.102-1993 andITU-TG.703.)LOW: Nominal 0.31 VpTiming:Internal ClockRecovered Clock9.3.2DS3 Measurements9.3.2.1Summary•Bit Errors•Frame Errors•Bipolar Violations•Receive Frequenc•Parity Errors•FEAC Messages•C-bit Errors•DS2 Frame Errors•FEBE•Pattern Slip9.3.2.2Logic•Bit Errors•Pattern Slips•Bit Error Rate•Pattern Loss Seconds•Bit Errored Seconds•Error Free Seconds•Pattern Losses•% Error Free Seconds9.3.2.3Bipolar Violations•BPV•BPV Rate•BPV Errored Seconds9-6T-BERD 2207User’s GuideSECTION 9 - SpecificationsDS3 Option Specifications 9.3.2.4Frame Errors•Frame Error Rate•FEBE Rate•Frame Error Seconds•DS2 Frame Errors•Out of Frame Seconds•DS2 Frame Error Rate•C-bit Errors•Received X-bit•C-bit Error Rate•Transmit X-bit•FEBE•Frame Loss Count9.3.2.5Parity•Parity Errors•Parity Error Rate•Parity Error Seconds9.3.2.6Signal•Signal Loss•Signal Loss Seconds•Receive Frequency•Receive Signal Level•Transmit FrequencyUser’s Guide T-BERD 22079-7。
ERSATZTEILKATALOG 产品 spare parts 目录说明书
5EUROTEC GROUP SERVICE - Spare parts distribution11004066REB004066COVER - 50/50312417041REB417041NUT, DOOR BUFFER13307003REB307003NUT-LEDGE, FOR ROD14304021REB304021ROD, DOOR GUIDE 50/500/453/463/50315325036REB325036PIN, DOOR HINGE 5016311019REB311019HINGE, DOOR 45/46/50..17325066REB325066LOCK PIN BETA 246/25018999108REB999108GRUPPO CALAMITA PORTA 453/463/500/50319022095REB022095PANEL, REAR CPL 50/503110480058REB480058CAP, RUBBER D.17111437081REB437081GASKET, DOOR - 50/503112033301REB033301BRACKET, FIXED FOR DOOR GASKET 50/503113994012DWS30GRUPPO SERRATURA EB/F 22/44114029590DOOR115015064RACK SLIDE SX.116015063RACK SLIDE DX.117480057REB480057CAP, RUBBER D.14118408006REB408006STUD, FOR TANK FILTER - GREY119459004REB459004PIPEHOLDER, RUBBER DI.34120459006REB459006FAIRLEAD, Di9/De16 22121030080REB030080PROTECTION, LOW. SOCLE 50/503122461019REB461019FOOT, ADJUST. D30 M8123012326FRONT PANEL125025444CONTROL PANEL21214104PLASTIC PROTECTION22211013FLAT WIRE23417119NUT, M3 PLASTIC WHITE24419036SPACER, M325227084PUSH BUTTONS ASSEMBLY26026073POLYESTERE27224003REB224003PRESSURE SWITCH - 55/3528224010PRESSURE SWITCH, DRAIN PUMP SAFETY 110/75 29035031REB035031UNION, Y-TYPE, PRESSURE SWITCH 760210423011REB423011CLAMP, SPRING-TYPE211143013REB143013PIPE, PVC GREEN 4X7212220011REB220011* TERMINAL BOARD, 5-POLES + EARTH FV.122213459005REB459005CABLE CLAMPS, STEAB art.5024214H.374339-2CABLE H07RN-F 5X2.5X3.0MT21580871MAGNETIC DOOR SWITCH216230086REB230086RESISTANCE, TANK 2700W/220V-3200W/240V 22/44/50 217456015REB456015O-ring 112 9.92X2.62218463007REB463007LUG, RESISTANCE PROTECTION219999160GRUPPO BULBO SONDA VASCA220231016TEMP. PROBE221230111RESIST.B.4900W/230-400V222456002REB456002O-ring 48x6,222369870BOILER HEATING ELEMENT PROTECTION22469871PROBE HOLDER225228010FUSE226999298SCHEDA GET50(2 DISPLAY)235229040RELAY 62.83.8.230.0300237214090EL.PROTECTION,TRANSP.453238228004FUSE, 5X20 4A FAST239210010FUSE-HODER240210011PLATE241209021PERISTALTIC DISPENSER (NBR-3)242468151DZR150NT UNION, EXTRA DET. CPL NM * WELDED243143194REB143194PIPE 4x6 CRISTAL, TRANSP.244143219REB143219TUBE, SANTOPRENE 6X10 FITTINGS+METAL RINGS 245121075REB121075FILTER, SUCT.INOX (775239-001)251236047REB236047THERM.,CONT. /S.95ø+/-3ø31441009REB441009INSERT, SEAL D10 COLL.S621-32437014REB437014GASKET, LOWER MANIFOLD S85033143174REB143174PIPE, WATER LOW.COLL. RINSE 5034111030NEUTRAL LOWER MANIFOLD ASS. E50NM+PLUG 35035064BRACKET, DRAIN PUMP FOR MANIFOLD 50NM36127026REB127026SLEEVE, PUMP DELIVERY 22/50037143240PIPE, H-)COND.UPPER38437041REB437041GASKET 3/4 GAS LOAD39929169RAT32TUBO DI CARICO DEL TERMOPLASTICO310240011REB240011LOADING S.VALVE 1-WAY311104060BOILER312143005SPG10PIPE, PRESSURE SWITCH TP 5x11 (CASER/15/NL C4N) 313209025RINSE AID DISPENSING PUMP314121017FILTER, RINSE-AID SUCT.315H.775601PIPE 4x6 CRISTAL BLUE PVC316142053REB142053OVERFLOW, DRAIN 50/503 NM317121078REB121078FILTER, DRAIN PUMP 463/503318303019REB303019RING, ELASTIC FOR DRAIN PUMP FILTER 503 319136023REB136023DRAIN, BENT 50/503320437063CGG42GASKET, DRAIN 50321417081CDP2NUT, PLASTIC 1'- 1/4322127050REB127050SLEEVE, RIGIDO ASP.P.S. 500/503323127044REB127044SLEEVE, SUCT.DRAIN PUMP 353/403324468152REB468152UNION, DRAIN CLEAN.3325127037REB127037SLEEVE, DRAIN CLEAN.3326144003REB144003RELIEF VALVE, DRAIN PUMP327423024REB423024CLAMP, PLAST.FOR DRAIN PUMP PIPE CLAMP. 328143178REB143178PIPE, DRAIN - 50329130105REB130105DRAIN PUMP (50/503/460/BD18)330130150DRAIN PUMP (50/503/460/BD18) 60HZ331143189REB143189TUBE, DRAIN SFIATO DVGW CLEAN.3332144011REB144011CHECK VALVE (EB)333143004REB143004PIPE, PRESSURE SWITCH TP 10X17 (CASER/15NL C4N) 41984005REB984005GRUPPO CAMPANA PRESSOST.35/4042423011REB423011CLAMP, SPRING-TYPE43468029REB468029UNION, PRESSURE SWITCH BELL44456020REB456020O-ring 3050 R49545437019REB437019GASKET, CAMP. PRESS. V.M.46107005REB107005PRESSURE SWITCH BELL EB 35/4047142052REB142052OVERFLOW 50/503 NM48136023REB136023DRAIN, BENT 50/50349437063CGG42GASKET, DRAIN 50410417081CDP2NUT, PLASTIC 1'- 1/4413478059SUPPORT, FILTER GREY+EXTENSION414437015REB437015GASKET, PUMP FILTER S651-415127041REB127041SLEEVE, SUCTION 463/503416929169RAT32TUBO DI CARICO DEL TERMOPLASTICO417437041REB437041GASKET 3/4 GAS LOAD418240016DEV3S16LOADING S.VALVE 1-WAY 3/4 230V PART.16L 419143246PIPE, -)SOFTENER421999288GRUPPO VALVOLA DEVIATR.CON RIDUTTORE 422143265NOT IN PRICE-LIST423143004REB143004PIPE, PRESSURE SWITCH TP 10X17 (CASER/15NL C4N) 424117007WATER SOFTNER425406998REB406998SALT CONTAINER NM426480005REB480005SALT CONTAINER SCREW CAP427456052REB456052O-ring 144428429011REB429011RING NUT, SALT CONT.429437034REB437034GASKET, D68D81S3 RUBBER51303029REB303029RING, DRIPPING 46/50..52437064REB437064GASKET, MANIFOLD, CENTR.UPP.5053143240PIPE, H-)COND.UPPER54115113PIPE, WASHINGEST.PL.+ SLEV.+115111 SP405 55127036REB127036SLEEVE, LOW.WASH.COND. 50/f56121139FILTER57121138FITER58408006REB408006STUD, FOR TANK FILTER - GREY61327006REB327006PIN, LOW.WASH/RINSE 21/45362990108GRUPPO LAV.RISC.SUPER.50/UNIVERSALE63106007RINSE ARM, RH S651-85064106006REB106006WASH.ARM,LH+ SCREW S651-850-50365106005RINSE ARM, LH S651-85066140007REB140007SPRAY S621-3-31-67429006REB429006RING NUT, RINSE S621-3-31-368429007REB429007RING NUT, WASHING S621-3-31-369140008REB140008SPRAY S621-3-31-610106008REB106008WASH.ARM, RH+ SCREW S651-850-503611447128REB447128KNOB, FIX, WASH. GREY612454002REB454002PAWL 21/31613437100PACKING614129039REB129039WASH-RINSE-ARM ASSB., LOWER 353/403RAL7012 61580959RINSE ASSEMBLY616926132CAP, PLASTIC FOR WASH. ARM (DWT312)61780623RING 22X9,5X161880697NUT61969632ARM BODY620456072O-RING 6X2621140025SPRAY D.2,562280345NEW WASH BOSS ASSEMBLY623303032RING, INOX WASH. SEAL X5624417111BUSHING, WASH-ARM X5625308031RING NUT, WASH.BUSH X5626325094WASH COMB PIN SHAFT627199058DISC, WATER FLOW REDUCER PLAST.E55628115075REB115075CENTR.PIPELINE - LOWER 50 (H=108)629437014REB437014GASKET, LOWER MANIFOLD S850633456060O-ring 2025(CGR2025)634456019REB456019O-ring 203763580700PERNO RISCIACQUO D14 M10X171130109REB130109PUMP HP 0.80 220/240-50 - 50/50072130119PUMP B237 HP 0.80 220/60 5073314001REB314001BEARING 6201/2Z74206003CONDENSER - 12.5 mF76315017REB315017FLANGE, W/COVERING DUCT B23777437049REB437049GASKET, PUMP 227778141002REB141002SEAL, MECH., REVOLVING D 1279124065WASH PUMP IMPELLER FOR B237 FOR DISH- WASHER 711116021REB116021PUMP SHELL, B237712315022REB315022FLANGE, PUMP LGB T-173/174713456031REB456031O-ring T30-1297 D.2714141007REB141007SEAL, MECH..D.26x13x5,5 BR.715124031RAG291IMPELLER, CLOSED 50HZ D.104 T170716124053IMPELLER, CLOSED 60HZ T173-175717116019REB116019PUMP SHELL, 50 T-173。
克罗尼流量计说明书
DIN 2501 ANSI B 16.5 (入口)压力
M9指示器附加部件
9 限位开关Kmin, Kmax, k2 概述.............................. 21
9.1 电气连接 ......................... 21 9.2 限位点设置....................... 22 9.3 限位开关K的确定 ............... 23 9.4 技术参数 ......................... 23 10 电信号输出ESK2A(HARTTM)
KROHNE 06/2013
金属管浮子流量计 H250/H250H/H250U 安装操作指导
2009F154-13
金属管浮子流量计 涡街流量计 流量开关 玻璃管浮子流量计 V型锥流量计 挡板流量计 电磁流量计 超声波流量计 质量流量计 液位测量仪表 通信技术 工程系统和解决方案 开关、计数器、显示仪、记录仪 温度测量仪表 压力表
15 40 1/2″ 150/300 25 40 1″ 150/300 50 40 2″ 150/300 80 16 3″ 150/300 100 16 4″ 150/300 10Nm~1.0Kpm~7.23ft.lbf
双头螺栓
最大力矩
ANSI
DIN
ANSI
DIN
150lbs
150lbs 300lbs Nm ft.lbf
概述 .............................. 24 10.1 电气连接 ......................... 24 10.2 HARTTM通讯 .................... 25 10.3 技术参数 ......................... 26 11 流量累计器ESK-Z
Mini-Circuits RCDAT-4000-120 1MHz-4GHz 120dB Progr
Programmable AttenuatorRCDAT-4000-120Product OverviewMini-Circuits’ RCDAT-4000-120 is a general purpose, single channel programmable attenuator suitable for a wide range of signal level control applications from 1 MHz to 4 GHz. The Attenuator provides 0 to 120 dB attenuation in 0.25 dB steps. Its unique design maintains linear attenuation change per dB, even at the highest attenuation settings.The attenuator is housed in a compact and rugged package with SMA female connectors on the bi-directional input and output RF ports, a standard Ethernet port (RJ45) and a USB type Mini-B power and control port.The attenuator can be controlled via USB or Ethernet (supporting both HTTP and Telnet network protocols). Full software support is provided and can be downloaded from our website any time at /softwaredownload/patt.html. The package includes our user-friendly GUI application for Windows ® and a full API with programming instructions for Windows ® and Linux ® environments (both 32-bit and 64-bit systems).USB / Ethernet50Ω 0 – 120 dB, 0.25 dB step 1 to 4000 MHzTrademarks: Windows is a registered trademark of Microsoft Corporation in the United States and other countries. Linux is a registered trademark of Linus Tor-valds. Mac is a registered trademark of Apple Corporation. Pentium is a registered trademark of Intel Corporation. Neither Mini-Circuits nor the Mini-Circuits RCDAT-series attenuators are affiliated with or endorsed by the owners of the above referenced trademarks.Mini-Circuits and the Mini-Circuits logo are registered trademarks of Scientific Components Corporation.Rev. JECO-012291EDR-11169Case Style: MS1897Software PackageThe Big Deal• Wide attenuation range, 120 dB • Fine attenuation resolution, 0.25 dB• Short attenuation transition time (650 ns)• Compact size, 2.5 x 3.0 x 0.85”• USB and Ethernet controlIncluded AccessoriesModel No.DescriptionQty.MUSB-CBL-3+3.3 ft. USB cable1Applications• Automated Test Equipment (ATE)• WiMAX, 3G, 4G, LTE, DVB Fading Simulators • Laboratory Instrumentation • Handover system Evaluation • Power level cycling1 Attenuator RF ports are interchangeable, and support simultaneous, bidirectional signal transmission, however the specifications are guaranteed for the RF in and RF out as noted on the label. There may be minor changes in performance when injecting signals to the RF Out port.2 Max accuracy defined as ±[absolute error+% of attenuation setting] for example when setting the attenuator to 110 dB attenuation the maximum error at 3500 MHz will be: ±(-7.0+0.1x110)= ±(-7.0+11)= ± 4.0 dB3 Isolation is defined as max attenuation plus insertion loss; this is the path loss through the attenuator when initially powered up. After a brief delay (~0.5 sec typically) the attenuator will revert to a user defined “power-up” state (either max attenuation or a pre-set value).4 Total operating input power from both RF In and RF Out out ports. Compression level not noted as it exceeds max safe operating power level.5 Tested with 1 MHz span between signals.6 Minimum Dwell Time is the time the RCDAT will take to respond to a command to change attenuation states without communication delays. In PC control add communication delays (on the order of msec for USB) to get actual response time.7Attenuation Transition Time is specified as the time between starting to change the attenuation state and settling on the requested attenuation state. Electrical Specifications 1 at 0°C to 50°CAbsolute Maximum RatingsOperating Temperature0°C to 50°CStorage Temperature-20°C to 85°CV USB Max.6VDC voltage at RF port16VTotal RF power for RF In & RF Out @ 1 to 10 MHz+13 dBm @ 10 to 6000 MHz+23 dBmPermanent damage may occur if any of these limits are exceeded. Operating in the range between operating power limits and absolute maximum ratings for extended periods of time may result in reduced life and reliability.Block DiagramConnectionsRF In (SMA female)RF Out (SMA female)USB(USB type Mini-B female)Network (Ethernet/LAN)(RJ45 socket)RCDAT response to communication interruptUSBSimultaneous, bidirectional RF signal transmission with symmetrical performanceRJ45(Ethernet)inchConnectionsRF IN (SMA female)RF OUT (SMA female)USB(USB type Mini-B female)Network (Ethernet/LAN)(RJ45 socket)4X #2-56 UNCQBracket OptionTop ViewBottom View2X SMA FEMALEInstruction for mounting bracket:1. Tool required: Phillips head screwdriver2. Mount the bracket over threaded holes on the bottom side with the fasteners provided with the bracket.Outline Drawing (MS1897)Typical Performance Curves-3.0-2.0-1.00.01.02.00100020003000400050006000Frequency (MHz)Attenuation Accuracy @ +25°Cvs. Frequency over Attenuation settingsA c c u r a c y (dB )-3.0-2.0-1.00.01.02.0Frequency (MHz)Attenuation Accuracy @ 0°Cvs. Frequency over Attenuation settingsA c c u r a c y (dB )-3.0-2.0-1.00.01.02.0Frequency (MHz)Attenuation Accuracy @ +50°Cvs. Frequency over Attenuation settingsA c c u r a c y (dB )0.030.060.090.0120.0150.0Frequency (MHz)vs. Frequency over Attenuation settings 0.030.060.090.0120.0150.0Frequency (MHz)vs. Frequency over Attenuation settings A t t e n u a t i o n (d B )0.030.060.090.0120.0150.0Frequency (MHz)vs. Frequency over Attenuation settings A t t e n u a t i o n (d B )A t t e n u a t i o n (dB )11000 2000 3000 4000 5000 60001 1000 2000 3000 4000 5000 60001 1000 2000 3000 4000 5000 60001 1000 2000 3000 4000 5000 60001 1000 2000 3000 4000 5000 60001 1000 2000 3000 4000 5000 6000Attenuation relative to Insertion Loss @ +25°C vs. Frequency over Attenuation settingsAttenuation relative to Insertion Loss @ 0°C vs. Frequency over Attenuation settingsAttenuation relative to Insertion Loss @ +50°Cvs. Frequency over Attenuation settingsFrequency (MHz)Frequency (MHz)Frequency (MHz)Frequency (MHz)Frequency (MHz)Frequency (MHz)Typical Performance Curves (Continued)Frequency (MHz)Attenuation Setting (dB)A t t e n u a t i o n A c c u r a c y (dB )24681012I n s e r t i o n L o s s (d B )Insertion Loss @ Input Power=0dBm Insertion Loss @ Input Power +20 dBmvs. Frequency over TemperaturesI n s e r t i o n L o s s (d B )Insertion Loss @ Input Power=+20dBm Insertion Loss @ Input Power 0dBm vs. Frequency over Temperatures1 1000 2000 3000 40005000 6000Frequency (MHz)Input VSWR @ +25°Cvs. Frequency over Attenuation settings1.01.21.41.61.82.02.22.4I n p u t V S W R (:1)vs. Frequency over Attenuation settings1 1000 2000 3000 4000 5000 6000Frequency (MHz)Output VSWR @ +25°Cvs. Frequency over Attenuation settings1.01.21.41.61.82.02.22.4O u t p u t V S W R (:1)vs. Frequency over Attenuation settings1 1000 2000 3000 4000 5000 6000Frequency (MHz)Input IP3 @ 0dB Attenuation vs. Frequency over TemperaturesI P 3(d B m )IP3@0dB Attenuation Frequency (MHz)Software & Documentation Download:• Mini-Circuits’ full software and support package including user guide, Windows GUI, DLL files, programming manual and examples can be downloaded free of charge from /softwaredownload/patt.html • Please contact ****************************** for supportGraphical User Interface (GUI) for Windows Key Features:• Manual attenuation setting• Sweep and Hop attenuation sequences directed from the PC, or entire sequence loaded into RCDAT.• Attenuator address configuration and Firmware upgrade • Attenuation at power up may be set to selected attenuation level or last attenuation state recorded.• USB, HTTP or Telnet control of RCDAT • Setting Ethernet configurationApplication Programming Interface (API)Programming manual: https:///softwaredownload/Prog_Manual-6-Programmable_Attenuator.pdfWindows Support:• API DLL files exposing the full switch functionality• ActiveX COM DLL file for creation of 32-bit programs • .Net library DLL file for creation of 32 / 64-bit programs• Supported by most common programming environments (refer to application note AN-49-001 for summary of tested environments)Linux Support:• Full attenuator control in a Linux environment is achieved by way of USB interrupt commands.ModelDescriptionRCDAT-4000-120USB/Ethernet Programmable AttenuatorOrdering Information Additional NotesA. Performance and quality attributes and conditions not expressly stated in this specification document are intended to be excluded and do not form a part of this specification document.B. Electrical specifications and performance data contained in this specification document are based on Mini-Circuit’s applicable established test performance criteria and measurement instructions.C. The parts covered by this specification document are subject to Mini-Circuits standard limited warranty and terms and conditions (collectively, “Standard Terms”); Purchasers of this part are entitled to the rights and benefits contained therein. For a full statement of the Standard Terms and the exclusive rights and remedies thereunder, please visit Mini-Circuits’ website at /MCLStore/terms.jspIncluded Accessories Part No.DescriptionMUSB-CBL-3+3.3 ft (1.0 m) USB Cable: USB type A(Male) to USB typeMini-B(Male)Optional AccessoriesDescriptionUSB-AC/DC-5 8,9AC/DC 5V DC Power Adapter with US, EU, IL, UK, AUS, and China power plugsMUSB-CBL-3+ (spare) 3.3 ft (1.0 m) USB Cable: USB type A(Male) to USB type Mini-B(Male)MUSB-CBL-7+ 6.6 ft (2.0 m) USB Cable: USB type A(Male) to USB type Mini-B(Male) CBL-RJ45-MM-5+ 5 ft (1.5 m) Ethernet cable: RJ45(Male) to RJ45(Male) Cat 5E cableBKT-66-02+Bracket Kit8 The USB-AC/DC-5 may be used to provide the 5VDC power input via USB port if operating the RCDAT with Ethernet control. Notrequired if using USB control.9 Power plugs for other countries are also available, Plugs for other countries are also available, if you need a power plug for a country not listed please contact ******************************。
Agilent ESA Series Spectrum Analyzers说明书
The ESA family of spectrum analyzers have proven and guaranteed performance with the flexibility to select the right level of functionality for your test needs. Take advantage of the best overall perfor-mance on a mid-performance spectrum analyzer. Industry best typical performance•Warm up time: 5 minutes•Third order intermodulation distortion: +16 dBm •Sensitivity: -166 dBm•Amplitude accuracy: ±0.4 dB•Overall phase noise (all carrier frequencies a): •-94 dBc/Hz (10 kHz)•-122 dBc/Hz (100 kHz)•-136 dBc/Hz (1 MHz)AgilentESA Series Spectrum AnalyzersData SheetExpress analyzer configurations •Basic AnalyzerExpress Option BAS •Standard AnalyzerExpress Option STD •Communications Test Analyzer Express Option COMDefinitions and ConditionsThe distinction between specifications and characteristics is described as follows.•Specifications d escribe the performance of parameters covered by the product warranty.(The temperature range is 0 °C to 55 °C, unlessotherwise noted.)•Characteristics d escribe prod uct performance that is useful in the application of the product, but isnot covered by the product warranty.•Typical performance d escribes ad itional prod uct performance information that is not covered by the product warranty. It is performance beyondspecification that 80% of the units exhibit witha 95% confidence level over the temperature range20 to 30 °C. Typical performance does not includemeasurement uncertainty.• Nominal values indicate the expected performance, or describe product performance that is useful in the application of the product, but is not covered by the product warranty.The following conditions must be met for the analyzer to meet its specifications.•The analyzer is within the one year calibration cycle.•If Auto Align All is selected:•After 2 hours of storage within the operating temperature range.•5 minutes after the analyzer is turned on with sweep times less than 4 seconds.•If Auto Align Off is selected:•When the analyzer is at a constant temperature, within the operating temperature range, for aminimum of 90 minutes.•After the analyzer is turned on for a minimum of 90 minutes and Align Now All has been run.•When Align Now All is run:•Every hour•If the ambient temperature changes more than 3 °C•If the 10 MHz reference changes•If Auto Align All but RF is selected:•When the analyzer is at a constant temperature, within the operating temperature range, for aminimum of 90 minutes.•After the analyzer is turned on for a minimum of 90 minutes and Align Now RF has been run.•When Align Now RF is run:•Every hour•If the ambient temperature changes more than 3 °C Table of ContentsDefinitions and Conditions2 Frequency Specifications3 Amplitude Specifications7 General Specifications12 Option Ordering14E4411B Frequency range E4403B E4408B BAS configuration 9 kHz - 1.5 GHz 9 kHz - 3 GHz9 kHz - 26.5 GHzCustom configurationN/AN/A(75 Ω input Option 1DP)1 MHz - 1.5 GHzE4402B E4404B E4405B E4407B STD or COM configuration9 kHz - 3 GHz 9 kHz – 6.7 GHz9 kHz – 13.2 GHz9 kHz - 26.5 GHz Custom configurationLow frequency extension Option UKB 100 Hz a - 3 GHz100Hz a - 6.7 GHz 100Hz a - 13.2 GHz100Hz a - 26.5 GHz External mixing Option AYZAdd 18 GHz - 325 GHzFrequency range Frequency range 100 Hz - 3 GHz2.85 - 6.7 GHz6.2 - 13.2 GHz12.8 – 19.2 GHz18.7 – 26.5 GHzBand 01234Harmonic (N b ) mixing mode1-1-2-4-4-gStandard analyzerCommunications testanalyzer or ESA withOption 1D5±2 x 10–6/year ±1 x 10–7/year (Opt. 1D5)±5 x 10–6/year±1 x 10–8/year b (Opt. 1D5)±5 x 10–7/year±1 x 10–8/year (Opt. 1D5)[0.5 % + 1/ (sweep points –1) ] x span [0.5 % + 1/ (sweep points –1) ] x span10 MHz1 - 30 MHzLogarithmicN/ARange = 0 Hz (zero span), 100 Hz to maximum frequency range of the analyzer AccuracySwp type linear 1% of span ±[0.5% x span + 2 x span/(sweep points – 1)]2% of span, nominalMarker frequency counter dAccuracy = ±(marker frequency x frequency reference error + counter resolution)Counter resolution = selectable from 1 Hz to 100 kHz Frequency spanSpan coefficient (SP)c 0.75 % x spanExternal reference10 MHzTemperature stability ±5 x 10–6/year±1 x 10–8/year bSettability ±5 x 10–7/year±1 x 10–8/yearFrequency readout accuracy (start, stop, center, marker)= ±(frequency indication x frequency reference error + SP c +15% of RBW + 10 Hz + 1 Hz x N a )Aging rate ±2 x 10–6/year±1 x 10–7/yearBasic analyzer Frequency referenceFrequency reference error = ± [(aging rate x time since last adjustment )+ settability + temperature stability]Standard analyzer Communications test analyzer or ESA with Option AYXor ESA with Option B7D/B7ESpan = 0 Hz 4 ms – 4000 s 50 ns a – 4000 s25 ns a - 4000 sSpan ≥ 100 Hz4 ms – 4000 sRF burst (B7E)Span = 0 Hz 401Span ≥ 100 Hz401Delayed trigger range 1 us to 400 s Sweep (trace) points Range2 - 8192101 - 8192Accuracy± 1%Trigger type bFree Run, Single, Line, Video, Offset, Delayed, ExternalGate (1D6)Basic analyzerSweep time and trigger Range 1 ms – 4000 sCommunications test analyzeror ESA with Option 1DR and 1D5(-3 dB)1 kHz – 5 MHz 1 kHz – 5 MHz 1 Hz to 5 MHz (-6 dB EMI)9 KHz, 120 kHz 9 KHz, 120 kHz 200 Hz, 9 kHz,120 kHz With 1DR c (-3dB)Add 100 Hz, 300 Hz Add 10 Hz - 300 Hz(-6 dB EMI)Add 200 Hz 200 Hz With 1DR and 1D5d N/A Add 1 Hz and 3 HzIncluded 1 Hz to 300 Hz1 kHz to 3 MHz5 MHz100 Hz to 300 Hz1 kHz to 5 MHz Rangewith 1DR < 15:1 synchronously tuned four poles, approximately Gaussian Video bandwidths (1-3-10 sequence)30 Hz to 3 MHz Adds 1, 3, 10 Hz for RBWs less than 1 kHz± 15%± 30%Selectivity (60 dB/3 dB bandwidth ratio)< 5:1 digital, approximately Gaussian RangeIncludedAccuracy± 10%Basic analyzer Standard analyzerResolution bandwidths (1-3-10 sequence)ESA-E E4411BE4403B/08Bwith Option 120aOffset fromCW signal≥ 1 kHz ≥ 10 kHz -93, -95 dBc/Hz-90, -94 dBc/Hz -100, -105 dBc/Hz -100, -105 dBc/Hz-106, -112 dBc/Hz -106, -112 dBc/Hz -118, -122 dBc/Hz -118, -122 dBc/Hz -125, -127 dBc/Hz -127, -129 dBc/Hz -131, -136 dBc/Hz -133, -136 dBc/Hz -135, -139 dBc/Hz -137, -141 dBc/Hz-100, -102 dBc/Hz -104, -106 dBc/Hz -113, -116 dBc/Hz -90, -94 dBc/Hz ≥ 20 kHz ≥ 30 kHz ≥ 100 kHz ≥ 1 MHz ≥ 5 MHz ≥ 10 MHz Option 1D5 only 100 msOption 1DR only 20 msOption 1DR & 1D520 ms≥ 30 kHz offsetfrom carrier CW signalSystem related sidebands ≤ -65 dBc + 20logN c≤ 10 Hz x N c ≤ 2 Hz peak-to-peak x N c≤ 150 Hz x N c (100 ms)≤ 10 Hz x N c (20 ms), Option 1DR≤ 2 Hz peak-to-peak x N c , (20 ms), Option 1DR & 1D5≤ 100 Hz x N c 1 kHz RBW, 1 kHz VBW≤ 150 Hz x N c (100 ms)≤ 30 Hz x N c (20 ms), Option 1DRResidual FM (peak-to-peak)StabilityNoise sidebands offset from CW signal with 1 kHz RBW, 30 Hz VBW and sample detectorSpec, typical dBc/Hz applies to all frequencies ≤ 6.7 GHz b, c -78 dBc/Hz (Option 1D5)Basic analyzerStandard and communications test analyzerE4402B/04B/05B/07BFigure 1. Typical ESA-E Series performance at 1 GHzAmplitude SpecificationsAmplitude specificationFigure 2. Specified dynamic range for E4407B spectrum analyzerInputs/outputsFront panelInput50 Ω type N (f); 75 Ω type N (f) (Option 1DP); 50 Ω APC 3.5 (m) (Option BAB) RF out50 Ω type N (f); 75 Ω BNC (f) (Option 1DQ)Probe power+ 15 Vdc, -12.6 Vdc at 150 mA maximum (characteristic)External keyboard6-pin mini-DIN, PC keyboards (for entering screen titles and file names)Headphone Front panel knob controls volumePower output0.2 Ω into 4 Ω (characteristic)AMPT REF out50 Ω BNC (nominal)IF INPUT (Option AYZ)50 Ω SMA (nominal)LO OUTPUT (Option AYZ)50 Ω SMA (nominal)Rear panel10 MHz REF OUT50 Ω BNC (f), > 0 dBm (characteristic)10 MHz REF IN50 Ω BNC (f), -15 to +10 dBm (characteristic)GATE TRIG/EXT TRIG IN BNC (f), 5 V TTLGATE /HI SWP OUT BNC (f), 5 V TTLVGA OUTPUT VGA compatible monitor, 15-pin mini D-SUB, (31.5 kHz horizontal, 60 Hz vertical sync rates, non-interlaced analog RGB 640 x 480IF, sweep and video ports (Option A4J or AYX)AUX IF OUT BNC (f), 21.4 MHz, nominal -10 to -70 dBm (uncorrected) AUX VIDEO OUT BNC (f), 0 to 1V, characteristic (uncorrected)HI SWP IN BNC (f), low stops sweep, (5 V TTL)HI SWP OUT BNC (f), (5 V TTL)SWP OUT BNC (f), 0 to +10 V rampGPIB interface (Option A4H)IEEE-488 bus connectorSerial interface (Option 1AX)RS-232, 9-pin D-SUB (m)Parallel interface(Option A4H or 1AX)25-pin D-SUB (f) printer port onlyOption OrderingFor information on ordering options, please refer to the ESA/EMC Spectrum Analyzer Configuration Guide, literature number 5968-3412E.More InformationFor the latest information on the Agilent ESA-E Series see our Web page at:Agilent Technologies’ Test and Measurement Support, Services, and Assistance Agilent T echnologies aims to maximize the value you receive, while minimizing your risk and problems. We strive to ensure that you get the test and measurement capabilities you paid for and obtain the support you need. Our extensive support resources and services can help you choose the right Agilent products for your applications and apply them successfully. Every instrument and system we sell has a global warranty. Support is available for at least five years beyond the production life of the product. T wo concepts underlie Agilent’s overall support policy: “Our Promise”and “Your Advantage.”Our PromiseOur Promise means your Agilent test and measurement equipment will meet its advertised performance and functionality. When you are choosing new equipment, we will help you with product information, including realistic performance specifica-tions and practical recommendations from experienced test engineers. When you use Agilent equipment, we can verify that it works properly, help with product operation, and provide basic measurement assistance for the use of specified capabilities, at no extra cost upon request. Many self-help tools are avail-able.Your AdvantageYour Advantage means that Agilent offers a wide range of additional expert test and measurement services, which you can purchase according to your unique tech-nical and business needs. Solve problems efficiently and gain a competitive edge by contracting with us for calibration, extra-cost upgrades, out-of-warranty repairs, and onsite education and training, as well as design, system integration, project management, and other professional engineering services. Experienced Agilent engineers and technicians worldwide can help you maximize your productivity, opti-mize the return on investment of your Agilent instruments and systems, and obtain dependable measurement accuracy for the life of those products./find/emailupdatesGet the latest information on the products and applications you select.Agilent T&M Software and ConnectivityAgilent’s Test and Measurement software and connectivity products, solutions and developer network allows you to take time out of connecting your instruments to your computer with tools based on PC standards, so you can focus on your tasks, not on your connections. Visit /find/connectivity for more information.By internet, phone, or fax, get assistance with all your test & measurement needsOnline Assistance:/find/assistProduct specifications and descriptions in this document subject to change without notice.© Agilent Technologies, Inc. 2004Printed in USA, April 28, 20045968-3386EPhone or FaxUnited States:(tel) 800 829 4444Canada:(tel) 877 894 4414(fax) 905 282 6495China:(tel) 800 810 0189(fax) 800 820 2816Europe:(tel) (31 20) 547 2323(fax) (31 20) 547 2390Japan:(tel) (81) 426 56 7832(fax) (81) 426 56 7840Korea:(tel) (82 2) 2004 5004(fax) (82 2) 2004 5115Latin America:(tel) (305) 269 7500(fax) (305) 269 7599Taiwan:(tel) 0800 047 866(fax) 0800 286 331Other Asia Pacific Countries:(tel) (65) 6375 8100(fax) (65) 6836 0252Email:*******************Agilent Email Updates。
Rotork Process Controls CML, CMQ, CMR Series Compa
Certificate No.:IECEx FMG 17.0007X Date of issue:2021-02-23Page 2 of 4Issue No: 8Manufacturer:Rotork Process Controls 5607 W. Douglas Ave Milwaukee, WI 53218 United States of AmericaAdditional manufacturing locations:This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements.This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amendedSTANDARDS :The equipment and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards IEC 60079-0:2017 Edition:7.0Explosive atmospheres - Part 0: Equipment - General requirementsIEC 60079-1:2014-06 Edition:7.0Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"IEC 60079-31:2013 Edition:2Explosive atmospheres - Part 31: Equipment dust ignition protection by enclosure "t"This Certificate does not indicate compliance with safety and performance requirementsother than those expressly included in the Standards listed above.TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in:Test Reports:Quality Assessment Report:GB/SIR/ExTR14.0296/00GB/SIR/ExTR14.0296/01GB/SIR/ExTR15.0132/00US/FMG/ExTR17.0005/00US/FMG/ExTR17.0005/01US/FMG/ExTR17.0005/02US/FMG/ExTR17.0005/03US/FMG/ExTR17.0005/04US/FMG/ExTR17.0005/05US/FMG/ExTR17.0005/06US/FMG/ExTR17.0005/07GB/FME/QAR14.0009/06Certificate No.:IECEx FMG 17.0007X Date of issue:2021-02-23Page 3 of 4 Issue No: 8EQUIPMENT:Equipment and systems covered by this Certificate are as follows: SPECIFIC CONDITIONS OF USE: YES as shown below:Refer to attached Annex for description of equipment.Refer to attached Annex for Specific Conditions of Use.Certificate No.:IECEx FMG 17.0007X Date of issue:2021-02-23Page 4 of 4 Issue No: 8DETAILS OF CERTIFICATE CHANGES (for issues 1 and above) Annex:Annex IECEx FMG 17-0007X.pdfMinor revisions to technical documents not affecting safety.Equipment DescriptionThe CMA (Compact Modulating Actuator) is self contained and used for continuous remote electrical operation of a control valve. The CMA consists of a main flameproof enclosure containing all of the electrical components and an attached smaller mechanical enclosure containing only gearing and mechanical power transfer devices. The Size 3 Actuators are available in three different functions: Linear, Quarter-turn, and Rotary. The Size 4& 5Actuators are available with Linear function only. The main enclosure is defined into “Sizes” per the table on the following page.The top part of the equipment is the flameproof “d” enclosure (the main enclosure), which is cylindrical in shape and includes a base and cover. The main enclosure is constructed out of the same aluminum either Low Pressure Gravity Cast (LPGC) or High Pressure Die Cast (HPDC). For Size 3 actuators, the cover has three different sizes: standard, intermediate and extended. For Size 4 & 5 actuators, there is one cover size. The enclosure houses a hand-knob which creates a cylindrical flamepath joint. The user may use the hand-knob to switch from manual to remote operation and control of the actuator. The cover forms a cylindrical flamepath joint with the base to which it is secured by fasteners. The joint is provided with suitable seals for environmental protection.The main enclosure houses all of the electronic components which make up the monitoring and control circuitry. This circuitry consists of power and logic PCBs both mounted on an aluminum bracket. The bracket is fastened to a cast aluminum mount which also acts as a mount for the DC motor. The whole assembly is fastened to the base. The operator uses an LCD display to program the actuator to control the motor and the logic PCB uses a feedback mechanism to sense the position of the output shaft. There are four ¾ NPT or M25 threaded entries to the enclosure for field wiring purposes.CML – Linear Compact Modulating ActuatorThe mechanical part of the linear enclosure is small in comparison to the main enclosure. This enclosure does not have any electrical components and contains mechanical components only. The enclosure houses a screw shaft which is driven by the DC motor. The shaft is supported by roller bearings and forms a flamepath through the enclosure. The shaft operates with a drive nut to provide the motion to the linear output shaft. The linear output shaft travels through a bronze bushing and into the hazardous area.This linear output shaft has two shoulder screws threaded into it at an angle perpendicular to the center line of the shaft. One screw is attached to a feedback shaft which penetrates into the electronics enclosure through a bronze bushing creating two flamepaths, one on either side of the bushing. Access to the shoulder screw is via an aluminum plate sealed from the environment. The other shoulder screw is tipped with an arrow to indicate the current position of the actuator to the user. The arrow can be seen through a window which is also sealed from the environment.The linear actuator is available in a low temperature variant which uses different seals to allow the equipment to be used in the lower minimum ambient temperature of -40°C.CMQ – Quarter-turn Compact Modulating ActuatorThe mechanical part of the quarter turn enclosure is housed in an aluminum lid cast separately from the base of the main enclosure. It is sealed to the base with three screws and an environmental seal. The drive is taken from the motor by the third stage pinion shaft, supported by roller bearings, and into the gear-train. There is a long flamepath along the length of the third stage pinion shaft between the bearings. The gear-train consists of three connected gears which reduce the output RPM and increase the torque. The output shaft is the final shaft passing the drive through the enclosure into the hazardous area through the lid via bronze bushings. The output shaft is connected to a feedback shaft which penetrates into the electronic enclosure through a bronze bushing creating two flamepaths, one on either side of the bushing. Sensors are connected to the feedback shaft to report the position of the actuator to the logic PCB. The final gear is attached to the output shaft and is a half gear with a flat face in order to limit the maximum turning movement of the actuator.The linear actuator is available in a low temperature variant which uses different seals to allow the equipment to be used in the lower minimum ambient temperature of -40°C.CMR – Rotary Compact Modulating ActuatorSimilar in design to the Quarter-turn, the Rotary variant mechanical side is housed in an aluminum lid cast separately from the base of the main enclosure. It is sealed to the base with three screws and an environmental seal. The drive is taken form the motor by the third stage pinion shaft, supported by roller bearings, and into the gear-train. There is a long flamepath along the length of the third stage pinion shaft between the bearings. The drive is transferred from this shaft onto the fourth stage pinion shaft and finally onto the output shaft which transfers the drive into the hazardous area via a bronze bushing. The output shaft is supported on a single steel roller bearing and also acts as a feedback shaft by passing into the main enclosure, creating a flamepath and allowing sensors to report the actuator position to the logic PCB.Page 1 of 3CML-a. Compact Modulating Actuators (CMA).CMQ-b. Compact Modulating Actuators (CMA).CMR-c. Compact Modulating Actuators (CMA).a = Size 750, 1500 or 3000.b = Size 1000.c = Size 89, 125 or 250.Note that the manufacturer has requested the size 1 & 2 actuators and the size 3, 4& 5actuators be listed on separate certificates. The CMA range includes the following variants:Model Size* MinimumThrust orTorqueMaximumThrust orTorqueSpeed StrokeShut-offThrust orTorqueCMR-50 1 2.3 Nm 5.6 Nm 11 RPM N/A N/ACML-100 1 177.9 N 444.8 N 6.35 mm/s 38.1 mm 889.6 N CMR-100 2 4.5 Nm 11.3 Nm 10 RPM N/A N/ACMR-200 2 9 Nm 22.6 Nm 5 RPM N/A N/ACMQ-250 1 11.3 Nm 28.2 Nm 5 s/qtr-turn N/A 42.3 Nm CML-250 2 444.8 N 1112 N 3.175 mm/s 38.1 mm 2200 N CMQ-500 2 22.6 Nm 56.5 Nm 7.5 s/qtr-turn N/A 84.8 Nm CMR-89 3 4.04 Nm 10.1 Nm 24 RPM N/A N/ACMR-125 3 5.6 Nm 14.1 Nm 18 RPM N/A N/ACMR-250 3 11.3 Nm 28.2 Nm 10 RPM N/A N/ACML-750 3 1334.5 N 3336.2 N 3.18 mm/s 50.8 mm 6670 N CMQ-1000 3 45.2 Nm 113.0 Nm 11 s/qtr-turn N/A 169.5 Nm CML-1500 4 2668.8 N 6672 N 4.57 mm/s 114.3 mm 10 kN CML-3000 55337.6 N 13.34 kN 4.57 mm/s 114.3 mm 20 kN*Note “Size” refers to performance aspects of the equipment; Sizes 1 and 2 are physically the same.Page 2 of 3Specific Conditions of Use1.The critical dimensions of the flamepath joints are as follows:CML-750 (Size 3 - Linear)Flamepath Maximum Gap (mm) Minimum Length L (mm) Lid/Base 0.15 12.8Base/Screw Shaft 0.235 37.3Base/Feedback Shaft Bushing -0.02 13.7Feedback Shaft Bushing/Shaft 0.06 13.7Handknob Shaft/Lid (short cover) 0.10 25.9Handknob Shaft/Lid (intermediate and extended covers) 0.10 15.7CMR-89, CMR-125, CMR-250 (Size 3 - Rotary)Flamepath Maximum Gap (mm) Minimum Length L (mm) Lid/Base 0.15 12.8Base/Pinion Shaft 0.235 37.3Base/Output Shaft 0.145 13.0Handknob Shaft/Lid (short cover) 0.10 25.9Handknob Shaft/Lid (intermediate and extended covers) 0.10 15.7CMQ-1000 (Size 3 - Quarter-turn)Flamepath Maximum Gap (mm) Minimum Length L (mm) Lid/Base 0.15 12.8Base/Pinion Shaft 0.235 37.3Base/Feedback Shaft Bushing -0.02 13.7Feedback Shaft Bushing/Shaft 0.06 13.7Handknob Shaft/Lid (short cover) 0.10 25.9Handknob Shaft/Lid (intermediate and extended covers) 0.10 15.7CML-1500 and CML-3000 (Size 4 & 5 - Linear)Flamepath Maximum Gap (mm) Minimum Length L (mm) Lid/Base 0.20 26.4Handknob Shaft Bushing/Base -0.01 25.9Handknob Shaft/Bushing 0.20 27.9Base/Screw Shaft Bushing 0.361 36.96Screw Shaft Bushing/ Shaft 0.1 68.5Note that the minimum radial clearance of shafts of rotating electrical machines shall be ≥ 0.05 mm2.Warning - the equipment has a non-metallic coating and has a potential static hazard. Clean only with a damp cloth.3.The screws securing the outer window frame contribute to the integrity of the flameproof enclosure and must not beremoved.Page 3 of 3。
Eaton 电路保护器 Series G 目录说明书
2Catalog Number SelectionThis information is presented only as an aid to understanding catalog numbers. It is not to be used to build catalog numbers for circuit breakers or trip units.Series G—EG-Frame (15–125 Amperes)Notes1Cannot be UL rated.2Available only as 125 and 160A sizes.Terminations/Hardware Terminals Mounting Hardware M = Metric end caps E = Imperial end caps G = Line/load standard B = Bolt-on Metric Imperial Metric —FrameEPerformance 600Y/347480415240B —181825E 18252535S 22354085H 256570100C 35100100200KMolded case switch2Standard/Application G = IEC/CE/UL/CSAAmperes016 1015020025030032 1035040045050060063 1070080090100110125160 1Number of Poles1 = One2 = Two3 = Three4 = Four—neutral 0% protected 7 = Four—neutral 100% protectedTrip Unit FF = Fixed fixedAF = Adjustable thermal fixed magnetic KS = Molded case switchE G H 3 015 FF Ge s y of C M A /F l o d y n e /H y d r a d y n e ŀ M o t i o n C o n t r o l ŀ H y d r a u l i c ŀ P n e u m a t i c ŀ E l e c t r i c a l ŀ M e c h a n i c a l ŀ (800) 426-5480 ŀ w w2Product SelectionComplete Breaker (Includes Frame, Trip Unit, Standard Terminals and Mounting Hardware) IC Rating at 415/480 VoltsEG-Frame—18/18Notes1 16, 32, 63 and 160A are not UL listed ratings.2 Adjustable thermal are not UL listed.3 Change the fourth digit to 7 for 100% neutral protection. Neutral is on the LH side.Maximum Continuous Amps at 40°C 1 Single-Pole Two-Pole Three-Pole Four-Pole 3Fixed Thermal, Fixed Magnetic Fixed Thermal, Fixed Magnetic Fixed Thermal, Fixed Magnetic Adjustable 2 Thermal,Fixed Magnetic Fixed Thermal, Fixed Magnetic Adjustable 2 Thermal,Fixed Magnetic Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number 15EGB1015FFG EGB2015FFG EGB3015FFG —EGB4015FFG —16EGB1016FFG EGB2016FFG EGB3016FFG —EGB4016FFG —20EGB1020FFG EGB2020FFG EGB3020FFG —EGB4020FFG EGB4020AFG25EGB1025FFG EGB2025FFG EGB3025FFG EGB3025AFG EGB4025FFG EGB4025AFG 30EGB1030FFG EGB2030FFG EGB3030FFG —EGB4030FFG —32EGB1032FFG EGB2032FFG EGB3032FFG EGB3032AFG EGB4032FFG EGB4032AFG 35EGB1035FFG EGB2035FFG EGB3035FFG —EGB4035FFG —40EGB1040FFG EGB2040FFG EGB3040FFG EGB3040AFG EGB4040FFG EGB4040AFG 45EGB1045FFG EGB2045FFG EGB3045FFG —EGB4045FFG —50EGB1050FFG EGB2050FFG EGB3050FFG EGB3050AFG EGB4050FFG EGB4050AFG 60EGB1060FFG EGB2060FFG EGB3060FFG —EGB4060FFG —63EGB1063FFG EGB2063FFG EGB3063FFG EGB3063AFG EGB4063FFG EGB4063AFG 70EGB1070FFG EGB2070FFG EGB3070FFG —EGB4070FFG —80EGB1080FFG EGB2080FFG EGB3080FFG EGB3080AFG EGB4080FFG EGB4080AFG 90EGB1090FFG EGB2090FFG EGB3090FFG —EGB4090FFG —100EGB1100FFG EGB2100FFG EGB3100FFG EGB3100AFG EGB4100FFG EGB4100AFG 125EGB1125FFG EGB2125FFG EGB3125FFG EGB3125AFG EGB4125FFG EGB4125AFG 160——EGB3160FFGEGB3160AFGEGB4160FFGEGB4160AFGEG-Framee s y of C M A /F l o d y n e /H y d r a d y n e ŀ M o t i o n C o n t r o l ŀ H y d r a u l i c ŀ P n e u m a t i c ŀ E l e c t r i c a l ŀ M e c h a n i c a l ŀ (800) 426-5480 ŀ w w2EG-Frame—25/25 Single-Pole UnavailableEG-Frame—25/25Notes1 16, 32, 63 and 160A are not UL listed ratings.2 Adjustable thermal are not UL listed.3 Change the fourth digit to 7 for 100% neutral protection. Neutral is on the LH side.Maximum Continuous Amps at 40°C 1 Two-Pole Three-PoleFour-Pole 3Fixed Thermal, Fixed MagneticFixed Thermal, Fixed Magnetic Adjustable 2Thermal,Fixed Magnetic Fixed Thermal, Fixed Magnetic Adjustable 2Thermal,Fixed Magnetic Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number 15EGE2015FFG EGE3015FFG —EGE4015FFG —16EGE2016FFG EGE3016FFG —EGE4016FFG —20EGE2020FFG EGE3020FFG —EGE4020FFG EGE4020AFG 25EGE2025FFG EGE3025FFGEGE3025AFG EGE4025FFG EGE4025AFG 30EGE2030FFG EGE3030FFG —EGE4030FFG —32EGE2032FFG EGE3032FFG EGE3032AFG EGE4032FFG EGE4032AFG 35EGE2035FFG EGE3035FFG —EGE4035FFG —40EGE2040FFG EGE3040FFG EGE3040AFG EGE4040FFG EGE4040AFG 45EGE2045FFG EGE3045FFG EGE3050AFG EGE4045FFG —50EGE2050FFG EGE3050FFG —EGE4050FFG EGE4050AFG 60EGE2060FFG EGE3060FFG —EGE4060FFG —63EGE2063FFG EGE3063FFG EGE3063AFG EGE4063FFG EGE4063AFG 70EGE2070FFG EGE3070FFG —EGE4070FFG —80EGE2080FFG EGE3080FFG EGE3080AFG EGE4080FFG EGE4080AFG 90EGE2090FFG EGE3090FFG —EGE4090FFG —100EGE2100FFG EGE3100FFG EGE3100AFG EGE4100FFG EGE4100AFG 125EGE2125FFG EGE3125FFG EGE3125AFG EGE4125FFG EGE4125AFG 160—EGE3160FFGEGE3160AFGEGE4160FFG EGE4160AFGEG-Framee s y of C M A /F l o d y n e /H y d r a d y n e ŀ M o t i o n C o n t r o l ŀ H y d r a u l i c ŀ P n e u m a t i c ŀ E l e c t r i c a l ŀ M e c h a n i c a l ŀ (800) 426-5480 ŀ w w22.2Molded Case Circuit BreakersSeries GEG-Frame—40/35Notes1 16, 32, 63 and 160A are not UL listed ratings.2 Adjustable thermal are not UL listed.3 Change the fourth digit to 7 for 100% neutral protection. Neutral is on the LH side.Maximum Continuous Amps at 40°C 1Single-Pole Two-Pole Three-Pole Four-Pole 3Fixed Thermal, Fixed Magnetic Fixed Thermal, Fixed Magnetic Fixed Thermal, Fixed Magnetic Adjustable 2Thermal, Fixed Magnetic Fixed Thermal, Fixed Magnetic Adjustable 2Thermal, Fixed Magnetic Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number 15EGS1015FFG EGS2015FFG EGS3015FFG —EGS4015FFG —16EGS1016FFG EGS2016FFG EGS3016FFG —EGS4016FFG —20EGS1020FFG EGS2020FFG EGS3020FFG —EGS4020FFGEGS4020AFG 25EGS1025FFG EGS2025FFG EGS3025FFG EGS3025AFG EGS4025FFG EGS4025AFG 30EGS1030FFG EGS2030FFG EGS3030FFG —EGS4030FFG —32EGS1032FFG EGS2032FFG EGS3032FFG EGS3032AFG EGS4032FFG EGS4032AFG 35EGS1035FFG EGS2035FFG EGS3035FFG —EGS4035FFG —40EGS1040FFG EGS2040FFG EGS3040FFG EGS3040AFG EGS4040FFG EGS4040AFG 45EGS1045FFG EGS2045FFG EGS3045FFG —EGS4045FFG —50EGS1050FFG EGS2050FFG EGS3050FFG EGS3050AFG EGS4050FFG EGS4050AFG 60EGS1060FFG EGS2060FFG EGS3060FFG —EGS4060FFG —63EGS1063FFG EGS2063FFG EGS3063FFG EGS3063AFG EGS4063FFG EGS4063AFG 70EGS1070FFG EGS2070FFG EGS3070FFG —EGS4070FFG —80EGS1080FFG EGS2080FFG EGS3080FFG EGS3080AFG EGS4080FFG EGS4080AFG 90EGS1090FFG EGS2090FFG EGS3090FFG —EGS4090FFG —100EGS1100FFG EGS2100FFG EGS3100FFG EGS3100AFG EGS4100FFG EGS4100AFG 125EGS1125FFG EGS2125FFG EGS3125FFG EGS3125AFG EGS4125FFG EGS4125AFG 160——EGS3160FFGEGS3160AFGEGS4160FFGEGS4160AFGEG-Framee s y of C M A /F l o d y n e /H y d r a d y n e ŀ M o t i o n C o n t r o l ŀ H y d r a u l i c ŀ P n e u m a t i c ŀ E l e c t r i c a l ŀ M e c h a n i c a l ŀ (800) 426-5480 ŀ w w w .c m a f h .c o m2 2.2Molded Case Circuit BreakersSeries GEG-Frame—70/65Notes1 16, 32, 63A are not UL listed ratings.2 Adjustable thermal are not UL listed.3 Change the fourth digit to 7 for 100% neutral protection. Neutral is on the LH side.Maximum Continuous Amps at 40°C 1Single-Pole Two-Pole Three-Pole Four-Pole 3Fixed Thermal, Fixed Magnetic Fixed Thermal, Fixed Magnetic Fixed Thermal, Fixed Magnetic Adjustable 2Thermal, Fixed Magnetic Fixed Thermal, Fixed Magnetic Adjustable 2Thermal, Fixed Magnetic Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number 15EGH1015FFG EGH2015FFG EGH3015FFG —EGH4015FFG —16EGH1016FFG EGH2016FFG EGH3016FFG —EGH4016FFG —20EGH1020FFG EGH2020FFG EGH3020FFG EGH3020AFGEGH4020FFG EGH4020AFG 25EGH1025FFG EGH2025FFG EGH3025FFG EGH3025AFG EGH4025FFG EGH4025AFG 30EGH1030FFG EGH2030FFG EGH3030FFG —EGH4030FFG —32EGH1032FFG EGH2032FFG EGH3032FFG EGH3032AFG EGH4032FFG EGH4032AFG 35EGH1035FFG EGH2035FFG EGH3035FFG —EGH4035FFG —40EGH1040FFG EGH2040FFG EGH3040FFG EGH3040AFG EGH4040FFG EGH4040AFG 45EGH1045FFG EGH2045FFG EGH3045FFG —EGH4045FFG EGH4050AFG 50EGH1050FFG EGH2050FFG EGH3050FFG EGH3050AFG EGH4050FFG —60EGH1060FFG EGH2060FFG EGH3060FFG —EGH4060FFG —63EGH1063FFG EGH2063FFG EGH3063FFG EGH3063AFG EGH4063FFG EGH4063AFG 70EGH1070FFG EGH2070FFG EGH3070FFG —EGH4070FFG —80EGH1080FFG EGH2080FFG EGH3080FFG EGH3080AFG EGH4080FFG EGH4080AFG 90EGH1090FFG EGH2090FFG EGH3090FFG —EGH4090FFG —100EGH1100FFG EGH2100FFG EGH3100FFG EGH3100AFG EGH4100FFG EGH4100AFG 125EGH1125FFGEGH2125FFGEGH3125FFGEGH3125AFGEGH4125FFGEGH4125AFGEG-Framee s y of C M A /F l o d y n e /H y d r a d y n e ŀ M o t i o n C o n t r o l ŀ H y d r a u l i c ŀ P n e u m a t i c ŀ E l e c t r i c a l ŀ M e c h a n i c a l ŀ (800) 426-5480 ŀ w w w .c m a f h .c o m2EG-Frame—100/100 Current Limiting (Single-Pole and Two-Pole Unavailable)EG-Frame—100/100Molded Case Switches4Notes1 16, 32, 63A are not UL listed ratings.2 Adjustable thermal is not UL listed.3 Change the fourth digit to 7 for 100% neutral protection. Neutral is on LH side.4 Molded case switches may open above 1250A.Maximum Continuous Amps at 40°C 1Three-Pole Four-Pole 0% Protected Neutral 3Fixed Thermal, Fixed MagneticAdjustable 2Thermal, Fixed Magnetic Fixed Thermal, Fixed Magnetic Adjustable 2Thermal, Fixed Magnetic Catalog Number Catalog Number Catalog Number Catalog Number 15EGC3015FFG —EGC7015FFG —16EGC3016FFG —EGC7016FFG —20EGC3020FFG EGC3020AFG EGC7020FFG EGC7020AFG 25EGC3025FFG EGC3025AFG EGC7025FFG EGC7025AFG 30EGC3030FFG —EGC7030FFG —32EGC3032FFG EGC3032AFG EGC7032FFG EGC7032AFG 35EGC3035FFG —EGC7035FFG —40EGC3040FFG EGC3040AFG EGC7040FFG EGC7040AFG 45EGC3045FFG —EGC7045FFG —50EGC3050FFG EGC3050AFG EGC7050FFG EGC7050AFG 60EGC3060FFG —EGC7060FFG —63EGC3063FFG EGC3063AFG EGC7063FFG EGC7063AFG 70EGC3070FFG —EGC7070FFG —80EGC3080FFG EGC3080AFG EGC7080FFG EGC7080AFG 90EGC3090FFG —EGC7090FFG —100EGC3100FFG EGC3100AFG EGC7100FFG EGC7100AFG 125EGC3125FFGEGC3125AFGEGC7125FFGEGC7125AFGCatalog Number EGK3125KSG EGK7125KSG EGK3160KSG EGK7160KSGEG-Framee s y of C M A /F l o d y n e /H y d r a d y n e ŀ M o t i o n C o n t r o l ŀ H y d r a u l i c ŀ P n e u m a t i c ŀ E l e c t r i c a l ŀ M e c h a n i c a l ŀ (800) 426-5480 ŀ w w2EG Bolt-On Complete Breaker (Includes Frame, Trip Unit and Mounting Hardware)EG-Frame—18 kAIC at 480 VacEG-Frame—35 kAIC at 480 VacNotes1 For bulk pack 24, add suffix BP24 and order quantities of 24.2 For bulk pack 12, add suffix BP12 and order quantities of 12.3 For bulk pack 8, add suffix BP8 and order quantities of 8.Maximum Continuous Amps at 40°C Single-PoleTwo-PoleThree-PoleFixed Thermal, Fixed Magnetic Fixed Thermal, Fixed Magnetic Fixed Thermal, Fixed Magnetic Catalog Number 1Catalog Number 2Catalog Number 315EGB1015FFB EGB2015FFB EGB3015FFB 20EGB1020FFB EGB2020FFB EGB3020FFB 25EGB1025FFB EGB2025FFB EGB3025FFB 30EGB1030FFB EGB2030FFB EGB3030FFB 35EGB1035FFB EGB2035FFB EGB3035FFB 40EGB1040FFB EGB2040FFB EGB3040FFB 45EGB1045FFB EGB2045FFB EGB3045FFB 50EGB1050FFB EGB2050FFB EGB3050FFB 60EGB1060FFBEGB2060FFB EGB3060FFB 70EGB1070FFB EGB2070FFBEGB3070FFB 80EGB1080FFB EGB2080FFB EGB3080FFB 90EGB1090FFB EGB2090FFB EGB3090FFB 100EGB1100FFB EGB2100FFB EGB3100FFB 110EGB1110FFB EGB2110FFB EGB3110FFB 125EGB1125FFBEGB2125FFBEGB3125FFBMaximum Continuous Amps at 40°C Single-PoleTwo-PoleThree-PoleFixed Thermal, Fixed Magnetic Fixed Thermal, Fixed Magnetic Fixed Thermal, Fixed Magnetic Catalog Number 1Catalog Number 2Catalog Number 315EGS1015FFB EGS2015FFB EGS3015FFB 20EGS1020FFB EGS2020FFB EGS3020FFB 25EGS1025FFB EGS2025FFB EGS3025FFB 30EGS1030FFB EGS2030FFB EGS3030FFB 35EGS1035FFB EGS2035FFB EGS3035FFB 40EGS1040FFB EGS2040FFB EGS3040FFB 45EGS1045FFB EGS2045FFB EGS3045FFB 50EGS1050FFB EGS2050FFB EGS3050FFB 60EGS1060FFB EGS2060FFB EGS3060FFB 70EGS1070FFB EGS2070FFB EGS3070FFB 80EGS1080FFB EGS2080FFB EGS3080FFB 90EGS1090FFB EGS2090FFB EGS3090FFB 100EGS1100FFB EGS2100FFB EGS3100FFB 110EGS1110FFB EGS2110FFB EGS3110FFB 125EGS1125FFBEGS2125FFBEGS3125FFBEG-FrameEG-Frame e s y o f C M A /F l o d y n e /H y d r a d y n e ŀ M o t i o n C o n t r o l ŀ H y d r a u l i c ŀ P n e u m a t i c ŀ E l e c t r i c a l ŀ M e c h a n i c a l ŀ (800) 426-5480 ŀ w w22.2Molded Case Circuit BreakersSeries GEG-Frame—65 kAIC at 480 VacLoad T erminalsNotes1 For bulk pack 24, add suffix BP24 and order quantities of 24.2 For bulk pack 12, add suffix BP12 and order quantities of 12.3 For bulk pack 8, add suffix BP8 and order quantities of 8.Maximum Continuous Amps at 40°C Single-PoleTwo-PoleThree-PoleFixed Thermal, Fixed Magnetic Fixed Thermal, Fixed Magnetic Fixed Thermal, Fixed Magnetic Catalog Number 1Catalog Number 2Catalog Number 315EGH1015FFB EGH2015FFB EGH3015FFB 20EGH1020FFB EGH2020FFB EGH3020FFB 25EGH1025FFB EGH2025FFB EGH3025FFB 30EGH1030FFB EGH2030FFB EGH3030FFB 35EGH1035FFB EGH2035FFB EGH3035FFB 40EGH1040FFBEGH2040FFB EGH3040FFB 45EGH1045FFB EGH2045FFB EGH3045FFB 50EGH1050FFB EGH2050FFB EGH3050FFB 60EGH1060FFB EGH2060FFB EGH3060FFB 70EGH1070FFB EGH2070FFB EGH3070FFB 80EGH1080FFB EGH2080FFB EGH3080FFB 90EGH1090FFB EGH2090FFB EGH3090FFB 100EGH1100FFB EGH2100FFB EGH3100FFB 110EGH1110FFB EGH2110FFB EGH3110FFB 125EGH1125FFBEGH2125FFBEGH3125FFBMaximum Breaker AmpsTerminal, Body MaterialWire TypeMetric Wire Range mm 2AWG Wire Range(Package of Three Terminals)Catalog NumberStandard Cu/Al Pressure T ype T erminals 15–50Aluminum Cu/Al 2.5–50#14–1/03TA125EF 60–125AluminumCu/Al16–70#6–3/03TA150EFEG-Framee s y of C M A /F l o d y n e /H y d r a d y n e ŀ M o t i o n C o n t r o l ŀ H y d r a u l i c ŀ P n e u m a t i c ŀ E l e c t r i c a l ŀ M e c h a n i c a l ŀ (800) 426-5480 ŀ w w w .c m a f h .c o m2Accessories Selection Guide and Ordering InformationEG-FrameLine and Load T erminalsEG-Frame circuit breakers and molded case switches have line and load terminals as standard equipment.Insert collar enclosing conductor as shown. Locate nut on top of conductor and tighten securely with screw and washer.Caution : Collar must surround conductor.Insert collar enclosing conductor and center on extrusion. Tighten securely with screw and washer. Endcap kits are used on the E-Frame breaker line side to connect busbar or similar electrical connections. Includes hardware.Notes1Standard line and load terminals.2Four-pole kit with four terminals.3T125EF3TA125EF 3TA150EF 3TA160EFKEF2RTWK, Two-Pole–Metric EF3RTWK, Three-Pole–Metric EF4RTWK, Four-Pole–Metric EF2RTDK, Two-Pole–Imperial EF3RTDK, Three-Pole–Imperial EF4RTDK, Four-Pole–ImperialControl Wire Terminal Kit GCWTKMultiwire ConnectorsMaximum Breaker AmpsTerminal Body MaterialWire TypeMetric Wire Range mm 2AWG Wire Range(Package of Three Terminals)Catalog NumberStandard Cu/Al Pressure T ype T erminals 125Steel Al 4–6#12-103T125EF 1125Steel Cu 2.5–95#14-3/03T125EF 1125Aluminum Cu/Al 2.5–50#14-1/03TA125EF 160Aluminum Cu/Al 16–70#6-3/03TA150EF 160Aluminum Cu/Al 35–120#3-2503TA160EFK 160AluminumCu/Al35–120#3-2504TA160EFK2e s y of C M A /F l o d y n e /H y d r a d y n e ŀ M o t i o n C o n t r o l ŀ H y d r a u l i c ŀ P n e u m a t i c ŀ E l e c t r i c a l ŀ M e c h a n i c a l ŀ (800) 426-5480 ŀ w w2Control Wire T erminal KitFor use with steel or stainless steel standard line and load terminals only.Interphase BarriersThe interphase barrier is available for extended insulationbetween circuit breaker poles. Specify quantity when ordering.Base Mounting Hardware—DIN Rail MountingMetric base mounting hardware is included with a circuit breaker or molded case switch. (Included with breaker.) If required separately, order S/N 8703C80G08.Note: English mounting hardware kit can be supplied separate. Catalog number is BMHE #6–32 x 3 inches for two-, three- and four-pole. Single-pole mounting hardware metric order 8703C80G11. English hardware 8703C80G12. Both sold in quantities of 100.Terminal ShieldsThe terminal shield is available for line terminal areas in three- and four-pole circuit breakers. Special terminal shields are also available for use when an electrical (solenoid) operator ismounted on the circuit breaker. The standard style number by pole for each terminal shield is for a package of 10 and is priced per each package. Special terminal shields are packaged individually.T erminal Shields—IP30 ProtectionTerminal End Covers (Gas Barrier)The terminal end cover is available for three-pole circuit breakers only. Two conductor opening sizes are available. Specify quantity (one per circuit breaker) when ordering.T erminal End CoversMultiwire ConnectorsField-installed multiwire connectors for the load side (OFF) end terminals. They are used to distribute the load from the circuit breaker to multiple devices without the use of separate distribution terminal blocks.Multiwire lug kits include mounting hardware, terminal shield insulators and tin-plated aluminum connectors to replace three mechanical load lugs. UL listed as used on the load side (OFF) end.EG-Frame Multiwire Connectors Ordering Information (Package of 3) 1Note1For four-pole kit, change “3” at beginning of catalog number to “4.”Catalog NumberControl wire terminal kit 5652B38G01Package of 12—priced individuallyCatalog NumberInterphase barriersEIPBKPackage of 12—priced individuallyCatalog NumberDIN rail adapter—single-pole EF1DIN DIN rail adapter—two-pole EGDIN DIN rail adapter—three- or four-poleEF34DINNumber of Poles Catalog Number 3EFTS3K 4EFTS4KConductor Opening Diameter Inches (mm) Catalog Number 6.35 (0.25)EEC3K 10.41 (0.41)EEC4KMaximum Amperes Wires per Terminal Wire SizeRange AWG Cu Kit Catalog Number 125314–23TA125E3K 125614–63TA125E6Ke s y of C M A /F l o d y n e /H y d r a d y n e ŀ M o t i o n C o n t r o l ŀ H y d r a u l i c ŀ P n e u m a t i c ŀ E l e c t r i c a l ŀ M e c h a n i c a l ŀ (800) 426-5480 ŀ w wV4-T2-26Volume 4—Circuit Protection CA08100005E—April 2AccessoriesAllowable Accessory CombinationsDifferent combinations of accessories can be supplied, depending on the types of accessories and the number of poles in the circuit breaker.EG-Frame AccessoriesLegend■ Applicable in indicated pole position❏ May be mounted on left or right pole—not both ● Accessory available/modification availableReference PageSingle-Pole Two-Pole Three-Pole Four-Pole DescriptionCenterLeftRightLeftCenterRightLeftCenterRightNeutralInternal Accessories(Only one internal accessory per pole)Alarm lockout (Make/Break)V4-T2-104——■——■——■—Alarm lockout (2Make/2Break)V4-T2-104——■——■——■—Auxiliary switch (1A, 1B)V4-T2-104——■——■——■—Auxiliary switch (2A, 2B)V4-T2-104——■——■——■—Auxiliary switch and alarm switch combination V4-T2-104——■——■——■—Shunt trip—standardV4-T2-104———■——■———Undervoltage release mechanism V4-T2-105———■——■———External Accessories End cap kitV4-T2-25—●●●●●●●●●Control wire terminal kit V4-T2-25●●●●●●●●●●Multiwire connectors V4-T2-25●●●●●●●●●●Base mounting hardware V4-T2-25●●●●●●●●●●Terminal shields V4-T2-25●●●●●●●●●●Terminal end covers V4-T2-25———●●●————Interphase barriersV4-T2-25—●●●●●●●●●Non-padlockable handle block V4-T2-102■■——■——■——Snap-on padlockable handle lock hasp V4-T2-102■■——■——■——Padlockable handle lock haspV4-T2-102——■❏—❏❏—❏—Walking beam interlock—requires two breakers V4-T2-102———●●●●●●●Plug-in adapters V4-T2-102—●●●●●●●●●Electrical operator V4-T2-102———●●●————Handle mechanismsV4-T2-407———●●●————Modifications (Refer to Eaton)Moisture fungus treatment V4-T2-100●●●●●●●●●●Freeze-tested circuit breakers—●●●●●●●●●●Marine/naval application, UL 489 Supplement SA and SB—●●●●●●●●●●C o u r t e s y o f C M A /F l o d y n e /H y d r a d y n e ŀ M o t i o n C o n t r o l ŀ H y d r a u l i c ŀ P n e u m a t i c ŀ E l e c t r i c a l ŀ M e c h a n i c a l ŀ (800) 426-5480 ŀ w wVolume 4—Circuit Protection CA08100005E—April V4-T2-272Technical Data and SpecificationsUL 489/IEC 60947-2 Interrupting Capacity (Symmetrical Amperes) (kA) RatingsDimensions and WeightsApproximate Dimensions in Inches (mm)EG-FrameEG-FrameApproximate Shipping Weight in Lbs (kg)EG-FrameNotes1DC ratings apply to substantially non-inductive circuits.2IEC only.3Two-pole circuit breaker, or two poles of three-pole circuit breaker.4Time constant is 3 milliseconds minimum at 10 kA and 8 milliseconds minimum at 42 kA.5Current limiting per UL 489.Circuit Breaker Type Number of Poles Volts AC (50/60 Hz)Volts DC 1120220–240277347380–415480600Y/ 347690 2125250 34I cu I cs I cu I cs I cu I cs I cu I cs I cu I cs EGB125135252518———————1010——2, 3, 4—2525——181818—————1010EGE1252, 3, 4—3535——25252518————1010EGS125110085433522——————3535——2, 3, 4—8543——40303522————3535EGH1251200100506530——————4242——2, 3, 4—10050——70356525————4242EGC125 53, 4—200200——10010010035————4242EGB160 23, 4—2525——181818—————1010EGE160 23, 4—3535——25252518————1010EGS160 23, 4—8543——40303522————3535Number of Poles Width Height Depth 1 1.00 (25.4) 5.50 (139.7) 2.99 (75.9)2 2.00 (50.8) 5.50 (139.7) 2.99 (75.9)3 3.00 (76.2) 5.50 (139.7) 2.99 (75.9)44.00 (101.6)5.50 (139.7)2.99 (75.9)Breaker Type Number of Poles 1234Breaker Type Number of Poles 34EGB125 1.5 (0.68) 2.0 (0.91) 3.0 (1.36) 4.9 (1.82)EGB160 3.0 (1.36) 4.9 (1.82)EGC125 1.5 (0.68) 2.0 (0.91) 3.0 (1.36) 4.9 (1.82)EGE160 3.0 (1.36) 4.9 (1.82)EGE125 1.5 (0.68) 2.0 (0.91) 3.0 (1.36) 4.9 (1.82)EGS1603.0 (1.36)4.9 (1.82)EGH125 1.5 (0.68) 2.0 (0.91) 3.0 (1.36) 4.9 (1.82)EGS1251.5 (0.68)2.0 (0.91)3.0 (1.36)4.9 (1.82)Front View Three-PoleFront Cover CutoutSide View(33.0)C LC o u r t e s y o f C M A /F l o d y n e /H y d r a d y n e ŀ M o t i o n C o n t r o l ŀ H y d r a u l i c ŀ P n e u m a t i c ŀ E l e c t r i c a l ŀ M e c h a n i c a l ŀ (800) 426-5480 ŀ w wV4-T2-28Volume 4—Circuit Protection CA08100005E—April 2EG-Frame With Earth Leakage ModuleEG-Frame With Current Limiter ModuleC o u r t e s y o f C M A /F l o d y n e /H y d r a d y n e ŀ M o t i o n C o n t r o l ŀ H y d r a u l i c ŀ P n e u m a t i c ŀ E l e c t r i c a l ŀ M e c h a n i c a l ŀ (800) 426-5480 ŀ w w。
福特制造业公司有限责任公司 FJT 系列接触器与 DME Jiffy-Tite - Jiffy-Ma
FS224P FS226P
90° HOSE STEM
1/4 I.D. 5/16 I.D. 3/8 I.D.
FS214 FS215 FS216
FS214P FS216P
STRAIGHT HOSE STEM
3/8 I.D. 1/2 I.D.
FS306 FS308
FS306P FS308P
45° HOSE STEM
.687 .843 1.00 1.00 1.00 1.187 1.250 1.500
.687 .937 .937 1.092 1.125 1.250 1.500 1.562
(F) – Suffix F for female pipe thread
A
C
1.000 1.278 1.373 1.450 1.574
FEMALE THREAD STEEL
1/2 FPT 3/4 FPT
FP554F FP556F
1/2" MALE THREAD BRASS
1/2 MPT FP554 3/4 MPT FP556
★ Available In Steel – Suffix S ■ Available In Brass – Suffix B
1/4 FPT 3/8 FPT
FP352F ■ FP353F ■
MALE THREAD BRASS
1/8 MPT 1/4 MPT 3/8 MPT 1/2 MPT
3/8"
FP351 FP352 ★ FP353 FP354
VALVED PLUG
MALE THREAD BRASS
3/8 MPT FP353V
ห้องสมุดไป่ตู้
21
Foster Manufacturing Company, Inc. • 2324 West Battlefield Road • Springfield, Missouri 65807
HFS DAQ 热流传感器数据收集系统用户手册说明书
HFS DAQ è un sistema di acquisizione dati progettato perleggere e registrare le misurazioni da sensori del flussotermico e della temperatura integrati HFS. Lo strumentoè dotato di 8 canali differenziali con 4 sensori HFS completiche possono essere collegati per registrare sia il flussotermico sia la temperatura da ciascun sensore. Il programmain dotazione consente all'utente di avviare e interromperela registrazione dei dati acquisiti dai sensori, visualizzarealternativamente i grafici del flusso termico e della temperaturaper i diversi canali e salvare un'analisi dei dati in un file .csv.IntroduzioneIl dispositivo è dotato di 8 canali differenziali a cui collegare i sensori. Ogni singolo sensore richiede 2 canali (uno per la misurazione del flusso termico e uno per la temperatura). Sono presenti 4 cavi che fuoriescono da ciascun sensore del flusso termico. I cavi rossi e bianchiintrecciati insieme sono quelli del sensore del flusso termico e devono essere inseriti nei canali 1, 3, 5 e 7 con il filo rosso nel terminale positivo di ciascun canale e il filo bianco nel terminale negativo. Ciò consente di inviare un segnale di flusso termico positivo per il calore che fluisce attraverso la parte superiore del sensore, sebbene sia possibile definire i flussi termici positivi e negativi in qualsiasi modo. I cavi blu chiaro e rosso intrecciati insieme sono quelli per latermocoppia e consentono di misurare la temperatura. Devono essere inseriti nei canali 2, 4, 6 e 8 con il filo blu nel terminale positivo e il filo rosso nel terminale negativo (questo è lo standard per le termocoppie di tipo T). L'immagine che segue mostra come collegare i sensori al dispositivo.Configurazione dell'hardwareManuale d'usodi HFS DAQ Iniziare l'installazione del software collegando il circuito al computer tramite il cavo USB incluso nella confezione. Se i driver Arduino non vengono installati automaticamente nel computer quando il dispositivo viene collegato, seguire queste istruzioni: Installazione del softwareUna volta collegati i sensori al dispositivo, è possibile collegare il dispositivo al computer tramite il cavo USB. Prima di aprire il software HFS DAQ, attendere qualche minuto dopo il collegamento della periferica affinché il computer la riconosca. Caricare quindi il file "HFS DAQ Program.exe" nella directory "HFS DAQ Program", nella cartella "release". L'avvio inizialepotrebbe richiedere alcuni secondi. In caso di errore, prima di caricare il programma assicurarsi che il computer riconosca il dispositivo Arduino e che il dispositivo sia collegato.In caso di errore, chiudere il software, scollegare il dispositivo, quindi ricollegare il dispositivo e riavviare il software. Anche sostituire la porta USB fisica utilizzata per il collegamento può risolvere il problema.Una volta caricato il programma, viene visualizzata una finestra con l'interfaccia utente. È necessario immettere il numero di sensori da cui si desidera registrare i dati. Immettere il numero di sensori (da 1 a 4) che si intende utilizzare.NOTA: i canali sono consecutivi, quindi se si sceglie di leggere solo 1 sensore, verrà automaticamente letto il sensore collegato nei canali 1 e 2. Allo stesso modo, se si sceglie di leggere 2 canali, saranno letti il primo sensore nei canali 1 e 2 e il secondo sensore nei canali 3 e 4 e così via.Fare clic sul pulsante "Set Number of Channels" (Imposta numero di canali) per impostare questa opzione. Assicurarsi che i sensori siano collegati a ciascun canale da leggere.Una volta selezionato il numero di canali, digitare la sensibilità del sensore collegato al canale 1 e fare clic sul pulsante "Set s1" (Imposta s1) per quel sensore. Le sensibilità per ciascun sensore sono indicate nei certificati di calibrazione forniti in dotazione. NON includere le unità qui. Digitare solo il numero, ad esempio 9,3 o 0,6, dove s1 corrisponde al sensore del flusso termico nel canale 1, s2 corrisponde al sensore nel canale 2 e così via.Utilizzo del software In Windows, fare clic su Start e selezionare l'opzione "Gestione dispositivi".In "Porte" o "Altri dispositivi", individuare "USB-SERIAL CH340" o "Dispositivo sconosciuto", fareclic con il pulsante destro del mouse e selezionare l'opzione per aggiornare il software del driver.2.1.3.4.5.6.Scegliere l'opzione per cercare il software dei driver nel computer.Accedere alla chiavetta USB e selezionare "Arduino Drivers" (Driver Arduino). Potrebbe essere necessario selezionare uno dei driver specifici, ad esempio "arduino.inf", ma la selezione della cartella dovrebbe essere sufficiente.Continuare la procedura e consentire a Windows di completare l'installazione.Una volta installati i driver, copiare la cartella "Data Reader Program" (Programma lettore dati) dalla chiavetta USB sul desktop. Aprire la cartella, quindi aprire la cartella "release" e selezionare e aprire il file denominato "HFS DAQ Program.exe".È possibile individuarlo facendo clic con il pulsante destro del mouse sul dispositivo,selezionando "Proprietà", facendo clic sulla scheda "Hardware" e facendo clic sulpulsante delle proprietà. Quindi fare clic sulla scheda "Driver"Collegare la chiavetta USB inclusa nella confezione al computer.Una volta impostate tutte le sensibilità, è possibile fare clic sul pulsante "Graph Window" (Finestra grafico). Viene visualizzata una nuova finestra in cui saranno visualizzati i dati.Sono ora disponibili alcune opzioni per il modo in cui si desidera acquisire i dati. Quando sifa clic sul pulsante "Start Data" (Avvia dati), il programma inizia a registrare i dati dai sensoriin background. È sempre possibile mettere in pausa i dati e salvarli andando in alto e selezionando "Save Data" (Salva dati). Quando l'utente salva i dati, viene creato un file denominato "test.csv" nella stessa cartella del programma. Per evitare che questo file venga sovrascritto, copiarlo inun'altra posizione prima di una nuova analisi dei dati. Il programma NON viene aggiunto al successivo nome file disponibile quando viene eseguita una nuova analisi dei dati.È anche possibile selezionare i diversi canali e visualizzare i grafici del flusso termico e della temperatura da ciascun sensore. È possibile verificare che funzioni posizionando la mano su uno dei sensori e guardando il grafico dal canale corrispondente per vedere il segnale. Nota:se si esegue il programma su un computer meno recente, i dati nei grafici potrebbero subiredei ritardi.。
赛米控丹佛斯电子 Board_93_GB_SKYPER_42_R 数据表
®Adaptor boardIGBT Driver CoreBoard 93 GB SKYPER 42 R Preliminary Data Features•Two output channels •Gold nickel finish •Failure managementTypical Applications*•Adaptor board for SKYPER 42 IGBT drivers in bridge circuits for industrial applications •PCB with gold plating •DC bus up to 1200VFootnotesIsolation test voltage with external high voltage diodeThe isolation test is not performed as a series test at SEMIKRONThe driver power can be expanded to 50µC with external boost capacitorsIsolation coordination in compliance with EN50178 PD2Operating temperature is real ambient temperature around the driver core Degree of protection: IP00This is an electrostatic discharge sensitive device (ESDS), international standard IEC 60747-1, Chapter IX* The specifications of our components may not be considered as an assurance of component characteristics. Components have to be tested for the respective application. Adjustments may be necessary. The use of SEMIKRON products in life support appliances and systems is subject to prior specification and written approval by SEMIKRON. We therefore strongly recommend prior consultation of our staff.Absolute Maximum Ratings SymbolConditionsValuesUnitV s Supply voltage primary 16V Iout PEAK Output peak current 30A Iout AVmax Output average current 150mA f max Max. switching frequency100kHz V CECollector emitter voltage sense across the IGBT1700V V isol IO Isolation test voltage input - output (AC, rms, 2s)4000V V isolPD Partial discharge extinction voltage, rms, Q PD ≤ 10pC1500V V isol12Isolation test voltage output 1 - output 2 (AC, rms, 2s)1500V R Gon min Minimum rating for external R Gon 0.8ΩR Goff min Minimum rating for external R Goff 0.8ΩT op Operating temperature -40...85°C T stgStorage temperature-40 (85)°CCharacteristics SymbolConditionsmin.typ.max.UnitV s Supply voltage primary side 14.41515.6V V i Input signal voltage on / off 15 / 0V V IT+Input treshold voltage HIGH 12.3V V IT-Input threshold voltage (LOW) 4.6V V G(on)Turn on output voltage 15V V G(off)Turn off output voltage-8V t d(on)IO Input-output turn-on propagation time 1.1µs t d(off)IOInput-output turn-on propagation time1.1µsAdaptor Board 93 SKYPER® 42 RTechnical ExplanationsRevision 04------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ This Technical Explanation is valid for the following parts:Related documents:Prepared by: Johannes Krapp------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ ContentApplication and Handling Instructions (2)Further application support (2)General Description (2)Dimensions (3)PIN Array (3)Setting Dynamic Short Circuit Protection (4)Collector Series Resistance (4)Adaptation Gate Resistors (5)Boost Capacitors (6)Environmental conditions (6)Mounting Notes (6)Please note:All values in this technical explanation are typical values. Typical values are the average values expected in large quantities and are provided for information purposes only. These values can and do vary in different applications. All operating parameters should be validated by user’s technical experts for each application.Application and Handling Instructions▪Please provide for static discharge protection during handling. As long as the hybrid driver is not completely assembled, the input terminals have to be short-circuited. Persons working with devices have to wear a grounded bracelet. Any synthetic floor coverings must not be statically chargeable. Even during transportation the input terminals have to be short-circuited using, for example, conductive rubber. Worktables have to be grounded. The same safety requirements apply to MOSFET- and IGBT-modules.▪Any parasitic inductances within the DC-link have to be minimised. Over-voltages may be absorbed by C- or RCD-snubber networks between main terminals for PLUS and MINUS of the power module.▪When first operating a newly developed circuit, SEMIKRON recommends to apply low collector voltage and load current in the beginning and to increase these values gradually, observing the turn-off behaviour of the free-wheeling diode and the turn-off voltage spikes generated across the IGBT. An oscillographic control will be necessary. Additionally, the case temperature of the module has to be monitored. When the circuit works correctly under rated operation conditions, short-circuit testing may be done, starting again with low collector voltage.▪It is important to feed any errors back to the control circuit and to switch off the device immediately in failure events.Repeated turn-on of the IGBT into a short circuit with a high frequency may destroy the device.▪The inputs of the hybrid driver are sensitive to over-voltage. Voltages higher than V S +0,3V or below -0,3V may destroy these inputs. Therefore, control signal over-voltages exceeding the above values have to be avoided.▪The connecting leads between hybrid driver and the power module should be as short as possible (max. 20cm), the driver leads should be twisted.Further application supportLatest information is available at . For design support please read the SEMIKRON Application Manual Power Modules available at .General DescriptionThe Board 93 GB SKYPER® 42 is an adaptor board for the IGBT module SKiM® 93 (spring contact). The board is paralleling three channels so the SKiM module can be used in half bridge configuration. The board can be customized allowing adaptation and optimization to the used IGBT module.The switching characteristic of the IGBT can be influenced through user settings, e.g. changing turn-on and turn-off speed by variation of R Gon and R Goff. Furthermore, it is possible to adjust the monitoring level and blanking time for the DSCP (see Technical Explanations SKYPER® 42 R).Please note:This technical explanation is based on the Technical Explanations for SKYPER®42 R. Please read the Technical Explanations SKYPER® 42 R before using the Adaptor Board.Dimensions116 PIN ArraySetting Dynamic Short Circuit ProtectionThe Vce formula for the Vce monitoring is described in the technical explanation of SKYPER 42 R. Collector Series ResistanceDesignation Shape SettingR105 MiniMELF (SMD) R VCE*Factory setting: not equippedTOPR205 MiniMELF (SMD) R VCE *Factory setting: not equippedBOTAdaptation Gate ResistorsBoost CapacitorsEnvironmental conditionsPlease refer to the technical explanation of SKYPER 42 R for the environmental conditions.Mounting NotesDISCLAIMERSEMIKRON reserves the right to make changes withoutfurnished in this document is believed to be accurate and reliable. However, no representation or warranty is given and no liability is assumed with respect to the accuracy or use of such information. SEMIKRON does not assume any liability arising out of the application or use of any product or circuit described herein. Furthermore,。
质量精益工具FMA,APC
C PK
K
2XM
PP
USL - LSL ˆS 6
(X i X) 2 ˆS n 1 i 1
n
d R d 2
Z USL
USL X
USL X ˆ
d T 2 (1 K )C P 6 d
M TU TL 2
d
Z L
LSL X
小偏倚
观测的平均值
范围较低的部分
观测的平均值
范围较高的部分
线性
观测的平均值 无偏倚
基准值
分辨力对测量系统变差的影响
• 分 辨 力 合 适 的 控 制 图
0.145 0.144 0.143 0.142 0.141 0.14 0.139 0.138 0.137 0.136 0.135 0.14555(UCL) 控制上限
作了控制图后派什么用途?
判断过程是否受控?
作控制图过程 是否受控
受控
不受控
继续
为什么?找到原因 作控制图过程 是否受控
持续改进
解决问题
变差分析步骤
1. 识别需分析的参数 2. 识别有无多产品/过程流 3. 决定抽样 4. 收集数据 5. 如有,则进行多变差分析 6. 件对件变差是否最大? 7. 检查件对件变差的一致性 8. 采取措施纠正过程 9. 件对件变差的估算 10. 检查数据的分布 11. 估算由于件对件变差引起的拒收率 12. 检查与件对件变差相关的时间对时间的变差的一致性 13. 6δ分析并确定措施 14. 用X-R图监控
否
感兴趣的是不 合格品率 是 否 样本量是常 数? 是 用np或p 图
否
感兴趣的是缺 陷数吗? 是 否
是
用P图
1kW PDM中波发射机故障检修与维护
1 引言哈尔滨正泰广播设备有限公司生产的ZHTPDM 1kW-Ⅲ中波发射机自动化控制程度较高,其中微机控制板和信号处理板是发射机的核心部分。
微机控制板是发射机的中控系统,按照工作要求具有对发射机实施定时开关机,对相关模拟量、开关量数据进行实时采集、运算、显示和存储,过荷自动复位及二次过荷自动关机,无功率、无调幅度自动报警等功能。
同时,它还备有RS422通信接口,通过接入台站自动化控制系统实施远程遥控。
信号处理板具有入射/反射指示、调幅度指示、过/欠推动检测、过流报警、封锁调制控制、功率增益控制和设备开关机控制等功能,从而使发射机在规定的技术指标范围内安全稳定合上空气开关S1、低压开关S2,然后按下键盘的“开机键”,开机低电平信电吸合,其接点K3-13、9吸合接地,此接地信号经过XS7-5去到键盘,用摘要:本文针对1kW PDM中波发射机在运行过程中出现的几个典型故障分别进行了分析、判断,通过对故障原因的分析,提出了故障的处理方法和今后的预防措施。
关键词:1kW PDM中波发射机典型故障 分析 检修 维护图1 电控盘原理图于开机LED指示,发射机开机过程完成。
其中,图1中的K1-6、10为自保接点。
2.1.4 故障检修过程使用万用表按照图2逐级测试,当测试到V10时,发现V10-e在开机状态无电压输出(正常值为+12V),由此判断三极管V10损坏。
从电路板拆卸下来测量出V10的b-e结断开,由于三极管V10损坏,+12V无法通过XS4-9给整机中间继电器K1(图1)线包提供电压,继电器K1不吸合,-72V电源无法正常工作,因此无法正常开机。
由于当时没有相同型号的三极管可以更换,故临时采用型号为C2068的三极管替代V10,开机后设备工作正常。
2.1.5 故障产生的原因设备运行过程中,信号处理板中的三极管V10(型号:2n2219)工作电流大(额定电流800mA)、管壳温度高。
另外,由于设备长期不停机连续工作加速了三极管的老化进程,使得三极管使用寿命变短,直至损坏。
单 predicted trunk 机械芯器维修手册说明书
Model Catalog NumberParts Manualc For Technical Assistance call: 800-227-2233, Fax: 888-329-8207To Order Parts call: 888-227-2233, Fax: 888-329-0234Single-Double Pallet Handler55G-FDS-B511cascadecorporationPublicationsG Single-Double 6085854Installation Instructions 213580Operator Guide6088640Service Manual6043535Driver Training Video – CD 679929Tool Catalog673964Literature Index Order FormREF QTY PART NO.DESCRIPTION6066238Frame Assembly u 116065007Frame216066261Inner Fork Carrier – LH316066260Inner Fork Carrier – RH416066540Bar52768711Capscrew, M16 x 35626069483Upper Pin Retainer746070661Retaining Ring846066832Seal946066556Bushing101209776Dowel Pin 1146068179Arm Bearing 1286028433Bearing Retainer Plugu Includes items 1-17.l See Cylinder page for parts breakdown.REF QTY PART NO.DESCRIPTION1316066390Fork Stop142765352Capscrew, M8 x 30152767811Roll Pin162424115Lube Fitting1726069835Relief Fitting1826066527Bearing1926066595Cylinder l2026133449Spring Cylinder2146066555Nut, M14224561667Nut, M20232768992Roll Pin2416088014Shim Kit nn If required for Fork tip alignment. Not included in Base Unit.Reference: Fastener Kit 6066604, SK-9261, SK-9718.55GCylinder55GREF QTY PART NO.DESCRIPTION6066595Cylinder116066597Shell22663694Plug, 3316066334O-Ring u416066370Backup Ring u526066318Piston Ring u616066303Rod Seal u716066320Piston Seal u816066280Rod Wiper u916065874Retainer1016066599Piston/Rod Assembly6068008Service Kitu Included in Service Kit 6068008.Reference: S-22885.Hydraulic Group55GREF QTY PART NO.DESCRIPTION 116067254Hose, 17.5 in.216067256Hose, 24.6 in.316067253Hose, 22.1 in.416067255Hose, 12.1 in.516067252Hose, 34.6 in.65604511u Fitting, 6-671604510u Plug, 6u Included in Fitting Group 6067705.Fork Carrier Group55GREF QTY PART NO.DESCRIPTION116066258Fork Carrier, RH 216066259Fork Carrier, LH 346066470Fork Stop48219596Capscrew, M8 x 16Reference:Fastener Kit 6066604, S-23049, S-23047.Forks55GREF QTY PART NO.DESCRIPTION 146066278Fork224221305Capscrew, M16 x 55 Reference: Fastener Kit 6066604, S-22893.Sideshift Mounting GroupREF QTY PART NO.DESCRIPTION6066607Sideshift Group (R20) s6071855Lower Hook Group (R4) t 116151472Upper Mounting Hook, RH 216070145Upper Mounting Hook, LH 316151643Anchor Bracket426127049Upper Bearing527403Grease Fitting61675548Sideshift Cylinder l71678525Clevis Pin82672726Cotter Pin91675550Restrictor Washer 1026066570Spacers Includes items 1-13 & 21-23.t Includes items 17-20.l See Sideshift Cylinder page for parts breakdown.REF QTY PART NO.DESCRIPTION111209542Key u1216131029Key u132219529Capscrew, M16 x 40 u142601676Fitting, 6-61586040801Capscrew, M16 x 60164767614Capscrew, M10 x 201726066574Lower Hook1826070833Lower Bearing194214991Capscrew, M16 x 45204667225Washer211671176Clevis Pin2216151473Capscrew, M12 x 1.75u Included with Anchor Bracket 6128972.Reference: Fitting Group 213099, Fastener Kit 6066604, SK-9261. Class IIISideshift CylinderREF QTY PART NO.DESCRIPTION675548Cylinder Assembly 11553857Nut21636851n Wiper 31553501Piston 41662452n Seal51638247n Back-up Ring 61641835n Seal 71675549Shell 81553499Rod912785n O-Ring101615128n Back-up Ring 111553500Retainer121553856Retaining Ring 1317202Retaining Ring 553861Service KitnIncluded in Service Kit 553861.P A R T S O R D E R I N G L O G P U R C H A S E S E R I A L R E FC A S C ADE C U S T O M E R D A T E O R D E R N U M B E RP A G E N O .Q T Y P A R T N O .P A R T N O .D E S C R I P T I O N P R I C EDo you have questions you need answered right now? Call your nearest Cascade Parts Department.Visit us online at AMERICASCascade CorporationParts Sales2501 Sheridan Ave. Springfield, OH 45505Tel: 888-CASCADE (227-2233) Fax: 888-329-0234Cascade Canada Inc.5570 Timberlea Blvd.Mississauga, OntarioCanada L4W-4M6Tel: 905-629-7777Fax: 905-629-7785Cascade do BrasilRua João Guerra, 134Macuco, Santos - SPBrasil 11015-130Tel: 55-13-2105-8800Fax: 55-13-2105-8899EUROPE-AFRICACascade Italia S.R.L. European Headquarters Via Dell’Artigianato 137030 Vago di Lavagno (VR) ItalyTel: 39-045-8989111Fax: 39-045-8989160Cascade (Africa) Pty. Ltd. PO Box 625, Isando 1600 60A Steel Road Sparton, Kempton Park South AfricaTel: 27-11-975-9240 Fax: 27-11-394-1147ASIA-PACIFICCascade Japan Ltd. 2-23, 2-Chome, Kukuchi Nishimachi Amagasaki, Hyogo Japan, 661-0978 Tel: 81-6-6420-9771 Fax: 81-6-6420-9777Cascade Korea121B 9L Namdong Ind.Complex, 691-8 Gojan-DongNamdong-KuInchon, KoreaTel: +82-32-821-2051Fax: +82-32-821-2055Cascade-XiamenNo. 668 Yangguang Rd.Xinyang Industrial ZoneHaicang, Xiamen CityFujian ProvinceP.R. China 361026Tel: 86-592-651-2500Fax: 86-592-651-2571Cascade India MaterialHandling Private LimitedNo 34, Global Trade Centre1/1 Rambaugh ColonyLal Bahadur Shastri Road,Navi Peth, Pune 411 030(Maharashtra) IndiaPhone: +91 020 2432 5490Fax: +91 020 2433 0881Cascade Australia Pty. Ltd. 1445 Ipswich Road Rocklea, QLD 4107 AustraliaTel: 1-800-227-223Fax: +61 7 3373-7333Cascade New Zealand15 Ra Ora DriveEast Tamaki, AucklandNew ZealandTel: +64-9-273-9136Fax: +64-9-273-9137Sunstream IndustriesPte. Ltd.18 Tuas South Street 5Singapore 637796Tel: +65-6795-7555Fax: +65-6863-1368cCascade Corporation 2011 7-2011。
Agilent E1416A Power Meter Data Sheet说明书
Data SheetAgilent E1416A Power Meter•1-Slot, C-size, message based •Single channel•±0.02 dB or ± 0.5% instrumentation accuracy •100 kHz to 110 GHz, sensor dependent •–70 to +44 dBm•1mW power referenceAgilent E1416ADescriptionThe Agilent Technologies E1416A Power Meter is a C-size,1-slot, message-based VXI module.It is a high-performance, single-channel, programmable, average power meter compatible with the Agilent 8480 family of thermocouple and diode power sensors.This power meter makes accurate and reliable average power measurements. With its powerful programming capability, exceptional accuracy and reliability, it lets you measure your test signal with speed, precision, and confidence!Refer to the Agilent Technologies Website for instrument driver availability and downloading instructions, as well as for recent product updates, if applicable.Product SpecificationsCharacteristicsFrequency:Allows entry of test signal frequencyfor cal factor selectionOffset:Allows measurement to be offset by± 99.99 dBResolution:Selection of 0.1, 0.01, and 0.001 dB.Auto Filter Mode automaticallyselects the required number ofaverages for the chosen range andresolutionAveraging:Selectable from 1 to 1024 readings (inpowers of 2)Duty cycle:Displays peak power representation ofmeasured RMS power for rectangularpulsesSensor tables:Allows entry and storage of up to 10sensor cal factor tables versusfrequencySave/recall states:Saves and recalls 10 completeE1416A operating statesGeneralFrequency:100 kHz to 110 GHz sensor dependent Power range:–70 to + 44 dBm (100 pW to 25 W),sensor dependentDynamic range:50 dB in 10 dB rangesResults units:W, dBm (absolute), %, dB relative Accuracy:± 0.02 dB or ± 0.5% (instrument,absolute mode). In ranges of 4 or 5,add sensor linearity percentage Zero set:± 0.5% of full scale on most sensitiverange. Divide by 10 for each higherrange, ± 1 countPower reference: 1.00 mW (50 MHz oscillator factoryset to ±0.7% traceable to NIST) FunctionsPower:YesOffset:YesAveraging:YesDuty cycle:Yes General SpecificationsVXI CharacteristicsVXI device type:Message based Size:CSlots:1Connectors:P1/2Shared memory:n/aVXI buses:n/aInstrument Drivers - See the Agilent Technologies Website (/find/inst_drivers) for driver availability and downloading.Command module firmware:n/a Command module firmware rev:n/aI-SCPI Win 3.1:n/aI-SCPI Series 700:n/aC-SCPI LynxOS:n/aC-SCPI Series 700:n/aPanel Drivers:YesVXI plug&play Win Framework:YesVXI plug&play Win 95/NT Framework:YesVXI plug&play HP-UX Framework:No Module Current–12 V:00+24 V:0.10.01–24 V:0.10.01–5.2 V00–2 V:00 Cooling/SlotWatts/slot:12.20∆P mm H2O: 1.00Air Flow liter/s:0.202Service Support Kit E1416A 915Additional User Manual E1416A 9163 Yr. Retn. to Agilent to 1 Yr. OnSite Warr.E1416A W015-ft (1.5 m) Power Sensor Cable11730A10-ft (3.0 m) Power Sensor Cable11730B20-ft (6.1 m) Power Sensor Cable11730C50-ft (15.2 m) Power Sensor Cable11730D100-ft (30.5 m) Power Sensor Cable11730E200-ft (61.0 m) Power Sensor Cable11730FHigh-power Thermocouple Power Sensor8481BMil Std 45662A Calibration Certification8481B 1BNExtra Manual Set8481B 910High-power Sensor, 100 kHz to 4.2 GHz8482BMil Std 45662A Calibration Certification8482B 1BN3-watt Power Sensor, 10 MHz to 18 GHz8481HMil Std 45662A Calibration Certification8481H 1BNExtra Manual Set8481H 9103-watt Power Sensor, 100 kHz to 4.2 GHz8482HMil Std 45662A Calibration Certification8482H 1BNExtra Manual Set8482H 910Power Sensor, 50 MHz to 26.5 GHz8485ASpecified Performance for 0.05-33 GHz8485A 033Mil Std 45662A Calibration Certification8485A 1BNExtra Manual Set8485A 910Power Sensor, 10 MHz to 18 GHz8481AAPC-7 Connector8481A 001Japanese Operating Manual8481A 030Mil Std 45662A Calibration Certification8481A 1BNExtra Manual Set8481A 910Power Sensor, 100 kHz to 4.2 GHz8482AJapanese Operating Manual8482A 030Mil Std 45662A Calibration Certification8482A 1BNExtra Manual Set8482A 91075-ohm Power Sensor, 100 kHz to 2 GHz8483AJapanese Operating Manual8483A 030Mil Std 45662A Calibration Certification8483A 1BNExtra Manual Set8483A 910Power Sensor, 26.5-40 GHz R8486APower Sensor, 33-50 GHz Q8486APower Sensor, 50 MHz to 50 GHz8487AV-band Power Sensor, 50 GHz to 75 GHz V8486AW-band Power Sensor W8486ADiode Power Sensor, 10 MHz to 18 GHz8481DMil Std 45662A Calibration Certification8481D 1BNExtra Manual8481D 910High-sensitivity Diode Power Sensor8485DSpecified Performance for 0.05-33 GHz8485D 033Mil Std 45662A Calibration Certification8485D 1BNExtra Manual8485D 910Diode Power Sensor, 50 MHz to 50 GHz8487DWaveguide Power Sensor, 26.5-40 GHz R8486DWaveguide Power Sensor, 33-50 GHz Q8486D34The E1416A is functionally equivalent to the Agilent 437B (1)or 70100A. It is compatible with all 8480 series sensors (and 11722A) as shown here.(1)The Agilent 437B has been obsoleted and replaced by the E4418B.Agilent Technologies’Test and Measurement Support,Services, and AssistanceAgilent Technologies aims to maximize the value you receive, while minimizing your risk and problems. We strive to ensure that you get the test and measurement capabilities you paid for and obtain the support you need. Our extensive support resources and services can help you choose the right Agilent products for your applications and apply them successfully. Every instrument and system we sell has a global warranty. Support is available for at least five years beyond the production life of the product. Two concepts underlie Agilent’s overall support policy: "Our Promise" and "Your Advantage."Our PromiseOur Promise means your Agilent test and measurement equipment will meet its advertised performance and functionality. When you are choosing new equipment, we will help you with product information, including realistic performance specifications and practical recommendations from experienced test engineers. When you use Agilent equipment, we can verify that it works properly, help with product operation, and provide basic measurement assistance for the use of specified capabilities, at no extra cost upon request. Many self-help tools are available.Your AdvantageYour Advantage means that Agilent offers a wide range of additional expert test and measurement services, which you can purchase according to your unique technical and business needs. Solve problems efficiently and gain a competitive edge by contracting with us for calibration, extra-cost upgrades, out-of-warranty repairs, and on-site education and training, as well as design, system integration, project management, and other professional engineering services. Experienced Agilent engineers and technicians worldwide can help you maximize your productivity, optimize the return on investment of your Agilent instruments and systems, and obtain dependable measurement accuracy for the life of those products.By internet, phone, or fax, get assistance with all your test & measurement needs.Online assistance:/find/assistPhone or FaxUnited States:(tel) 1800 452 4844Canada:(tel) 1877 894 4414(fax) (905) 282 6495China:(tel) 800 810 0189(fax) 1***********Europe:(tel) (3120) 547 2323(fax) (3120) 547 2390Japan:(tel) (81) 426 56 7832(fax) (81) 426 56 7840Korea:(tel) (82 2) 2004 5004(fax) (82 2) 2004 5115Latin America:(tel) (305) 269 7500(fax) (305) 269 7599Taiwan:(tel) 080 004 7866(fax) (886 2) 2545 6723Other Asia Pacific Countries:(tel) (65) 375 8100(fax) (65) 836 0252Email:*******************Product specifications and descriptions in this document subject to change without notice.©Agilent Technologies, Inc. 2001Printed in USA September 1, 20015965 5564E。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
普迪美技术通信No. 16001 PdM Technical Communication
Date: 2016/04/09
ESA 诊断电机轴承故障
某中外合资石化公司巡检设备,发现电机振动较大,且这台电机的转子之前发生过端环开裂现象,是利用EMPATH电动机故障诊断系统自动诊断的。
工厂怀疑电机又出现电气故障,使用EMPATH对电机进行故障诊断,发现电机轴承发生了故障,并非电机的电气故障,然后振动方法确认了电机轴承问题。
ESA技术再一次保证了设备的正常安全运行。
电机为铸铝式鼠笼电机,铭牌参数:500KW,2980rpm,6KV,58A。
自动分析诊断结果:
编号分析和发现维修建议
703-8023 2016/03/03 转子健康正常;
存在可疑的与轴承故
障有关的特征频率。
发现潜在轴承故障问
题,进行振动确认。
EMPATH电动机故障诊断系统对于轴承故障诊断采用两种方法进行诊断:
1.已知轴承型号,利用软件提供的轴承
数据库选择对应的轴承型号,寻找轴
承故障的特征频率进行诊断,与振动
诊断方法一样。
轴承输入
2.在电流频率里面寻找非整数倍转速
频率,这些频率极有可能与轴承状态
有关。
出现这些频率后,建议振动分
析。
3.
对于滑动轴承,
使用关联分析,
结合
静态和动态偏心故障指示,可判断是
否松动等其它一些问题。
数据对比
利用EMPATH的数据叠加对比功能,可清
楚的看到电机转子是正常的。
红色箭头指示
之前端环开裂时的特征频率,蓝色箭头指示
这次笼条健康时的频谱。
输入电机轴承型号
未发现轴承部件损坏的故障特征峰。
软件自动诊断结果
电流解调谱(转速的1/9倍频)
电流频谱(转速的非整数倍频率42.094)
使用瑞典VMI公司的VIBER X5对电机的前
后轴承进行了数据采集,进行振动确认。
发现电机驱动端速度值偏高,最高达到
7.02mm/s。
频谱中主要表现为转频及其谐频,
部分频谱出现高倍谐频。
时域波形存在摩擦、松动信号,电机驱
动端轴承存在跑圈松动或游隙过大问题。
现场确认:实际解体检查发现为轴承在
轴承室内咣动导致。
[汪斌、王晓阳稿]。