BLD800多功能仪表技术说明书解析
托利多T800技术手册
常锡路111号
Zip:213001
Tel:6642040
Fax:6641991
P/N:151923 (Sep-05)
©2002 Mettler Toledo,Inc. Printed in China
*151923*
©梅特勒-托利多(常州)称重设备系统有限公司,2002 Mettler Toledo版权所有。未经许可不得翻印、修改或引用。 METTLER TOLEDO©、T800™和 TraxDSP© 均为梅特勒-托利多公司的注册商标
t800称重显示仪网络型智能称重终端技术手册tmt800r03151923mettlertoledo梅特勒托利多常州称重设备系统有限公司常锡路111号tel
.
T800
称重显示仪
-- 网络型智能称重终端
技术手册
TM T800 R03 (151923)
METTLER TOLEDO
梅特勒-托利多(常州)称重设备系统有限公司
3.1 面板和键盘.............................................................................................................................................10 3.2 文字输入 .................................................................................................................................................12 3.3 开机..........................................................................................................................................................13 3.4 基本称重功能.........................................................................................................................................13 3.5 F1~F4功能.............................................................................................................................................14 3.6 数据存储、打印功能............................................................................................................................15 3.7 数据汇总功能.........................................................................................................................................15 3.8 时间、日期设置.....................................................................................................................................16 3.9 预置点值设置.........................................................................................................................................17
多功能仪表使用说明
★★★配套意大利ZAPI控制器★★★MDI仪表说明书合肥钦力电子有限公司1 特性1.1 特点1.MDI多功能数字仪表适用于所有装有ZAPI电控器的各种形式的电动车辆。
2.MDI多功能数字仪表的信号取自斩波器,而不是电瓶,这样不同电压等级的车辆也可用同一仪表。
3.电瓶的放电状态由微处理器进行一定的换算模拟获得。
该换算考虑了制动及起动等大电流情况对电瓶的影响。
4.用MDI数字式手持单元,可以选择100种不同放电曲线。
5.MDI多功能数字仪表是一个以微处理器为基础的系统。
对电瓶放电状态测量是高精度的,具有很高的可靠性和灵敏度。
同时MDI多功能数字仪表还可以显示工作小时和电控系统故障。
6.MDI多功能数字仪表有三个内部功能。
●显示放电状态。
●工作小时。
●显示电控系统故障。
7.MDI多功能数字仪表不直接连到电瓶,而仅与斩波器相连。
与传统显示仪表相比,MDI多功能数字仪表无需复杂接线,也节省了安装时间。
1.2 显示功能说明。
1.2.a 发光二极管显示功能MDI多功能数字仪表用发光二极管显示电瓶放电状态。
MDI多功能数字仪表有五个发光二极管,一红四绿,表示电瓶的放电状态。
充足电时,四个绿色发光二极管全亮。
随着电瓶不断放电,四个绿灯随电瓶剩余电量的减少逐步并按一定顺序熄灭,直至电瓶欠压,红灯亮,表示电瓶开始欠压。
1.2.b 液晶显示功能小时计:在MDI多功能数字仪表中部装有液晶显示器,它可以用来显示1.工作小时(以实际方式显示工作时间,例如30小时显示为”H 30”或”L 30”) 2.系统故障,MDI多功能数字仪表显示故障状态时是以相应的代码表示,故障发生时,红色发光二极管将闪烁,以引起注意。
3.软件版本:电锁刚闭合时,MDI多功能数字仪表显示EPROM中的软件版本,即EP××。
4.其它信息,MDI多功能数字仪表上有三种图案,分别告知司机下列信息:“L”图案:表示车辆处在“软”方式工作状态,在这种状态下,最大速度和加速度都被减小了。
DXI800 中文手册
2005 Beckman Coulter, Inc. P/N 986266E 3/05
i
UniCel DxI 800 使用说明
目录
4 样品架和样品容器 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-1
本手册与 UniCel DxI Access 免疫分析系统 一同使用。
Access、 AccuTnI、 DxI、 Hybritech、 Ostase、 UniCel 以及 BECKMAN COULTER 徽标是 Beckman Coulter, Inc. 的商标
UniCel DxI 800 使用说明
2 关闭和重新启动 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-1
DW800多功能电力仪表说明书
DW800多功能电力监控仪表产品说明书V1.0烟台磐能电气控制系统有限公司版权所有翻印必究目录一、产品概述: (3)1.1测量 31.2选装模块 41.3前面板 41.4控制与事件 51.5技术指标 5二、安装与接线: (6)2.1环境 62.2电源82.3接线图82.4通讯102.5开关量输入112.6继电器输出11三、测量参数 (11)3.1电压113.2电流123.3有功功率123.4无功功率123.5功率因数123.6频率12四、谐波124.1概述124.2电压谐波134.3电流谐波13五、电度及复费率统计 (13)5.1概述135.2有功电度145.3无功电度145.4复费率电度14六、事件记录 (14)6.1概述146.2事件类型146.3事件发生时间156.4事件格式15七、控制系统 (15)7.1概述157.2自控方式15八、显示操作 (17)8.1概括178.2按键功能188.3数据查询188.4就地配置23九、通讯329.1通讯介质329.2通讯协议329.3通讯参数32一、产品概述:DW800多功能电力监控仪表是一种功能强大﹑安全可靠的测控装置,可广泛应用于电力系统、环境监控、低压配电等自动化领域。
它实现了如下的功能:◇实时参数测量◇电度计量◇谐波分析◇事件记录◇控制系统◇复费率统计◇需量统计◇MODBUS通讯◇DI/DO◇模拟通道输出1.1测量DW800多功能电力监控仪表提供全方位的测量功能,可以充分满足低压或者高压三相电力网络中电气监控的要求。
仪表提供的测量如下表所示:参数量显示瞬态有效值电压相电压和线电压一次侧值二次侧值电流单相一次侧值二次侧值有功功率单相和总和一次侧值二次侧值无功功率单相和总和一次侧值二次侧值视在功率单相和总和一次侧值二次侧值功率因数单相和总线一次侧值一次侧值频率一次侧值一次侧值电度有功电度输入和输出一次侧值一次侧值无功电度感性和容性一次侧值一次侧值谐波电压3到37奇次分量百分比百分比电流3到37奇次分量百分比百分比需量电流相一次侧值二次侧值有功总值一次侧值二次侧值无功总值一次侧值二次侧值1.2选装模块DW800多功能电力监控仪表可以随时现场装配选项各种模块功能。
多功能电力仪表使用说明书
多功能电力仪表使用手册使用手册USER MANUAL目录一、多功能电力仪表使用手册 (2)1、概述 (2)2、技术参数 (2)3、编程和使用 (3)测量显示 (3)编程操作 (5)4、通迅 (10)通迅报文举例 (11)MODBUS地址信息表 (11)5、功能输出 (13)二、多功能三相电压、三相电流、有功电度、无功电度表使用手册 (14)1、概述 (14)2、使用 (14)三、多功能有功电度、无功电度使用手册 (16)4、概述 (16)5、使用 (16)四、多功能三相电流、有功电度表使用手册 (18)1、概述 (18)2、使用 (18)五、接线图 (19)120*120接线图 (20)96*96接线图 (21)80*80接线图 (22)72*72接线图 (23)六、常见问题及解决方法: (24)1多功能电力仪表-—使用手册一、概述多功能电力仪表是一种具有可编程测量、显示、数字通讯和电能脉冲输出等功能的多功能电力仪表,能够完成电量测量、电能计量、数据显示、采集及传输,可广泛应用变电站自动化,配电自动化、智能建筑、企业内部的电能测量、管理、考核.测量精度为0。
5级、实现LED 现场显示和远程RS—485数字接口通讯,采用MODBUS—RTU通讯协1)辅助电源:多功能电力仪表具备通用的(AC/DC)电源输入接口,若不作特殊声明,提供的是AC/DC85~270V电源接口的标准产品,保证所提供的电源适用于该系列的产品,以防止损坏产品。
注:采用交流供电时,建议在火线一侧安装1A保险丝电力品质较差时,建议在电源回路安装浪涌抑制器防止雷击,以及快速脉冲群抑制器。
2)输入信号:多功能电力仪表采用了每个测量通道单独采集的计算方式,保证了使用时完全一致对称,其具有多种接线方式.适用于不同的负载形式。
注:具体接线及仪表参数(脉冲常数等)见仪表所带接线图。
说明:A、电压输入:输入电压应不高于产品的额定输入电压(100V或400V),若无注明,出厂为AC0~500V、高于500V应考虑使用PT,在电压输入端须安装1A保险丝.B、电流输入:标准额定输入电流为5A,大于5A的情况应使用外部CT.如果使用的CT上连有其它仪表,接线应采用串接方式,去除产品的电流输入连线之前,一定要先断开CT一次回路或者短接二次回路.建议使用接线排,不要直接接CT,以便拆装。
精密仪器仪表使用方法说明书
精密仪器仪表使用方法说明书尊敬的用户:感谢您选择使用本公司的精密仪器仪表。
为了确保您能够正确、高效地使用该仪器仪表,特为您准备了本使用方法说明书。
请您仔细阅读并按照说明进行操作。
一、仪器概述本仪器仪表采用先进的技术和优质的材料制造而成,具有精度高、稳定性好、使用寿命长等特点。
主要适用于各种工业、实验室和科研领域,用于测量、监测、控制等目的。
二、安全须知1. 请仔细阅读本说明书并按照操作要求正确使用仪器。
2. 在使用过程中请戴好个人防护设备,确保安全。
三、仪器使用步骤1. 准备工作1.1. 根据实际需求选择适当的使用环境。
1.2. 将仪器连接电源,并确保电源电压与仪器要求相符。
1.3. 检查仪表表面是否有损坏,如有损坏请勿使用。
2. 仪器设置2.1. 打开仪器电源开关,待仪器正常启动。
2.2. 按照仪器屏幕提示进行相关设置,如语言、单位等。
3. 仪器操作3.1. 根据实际需求选择合适的测量模式。
3.2. 按照仪器提示操作测量控制面板。
3.3. 观察仪器显示屏上的数据,并进行相关分析。
4. 仪器维护4.1. 使用完毕后,请将仪器从电源中断开。
4.2. 清洁仪器表面,确保无积尘、油污等。
4.3. 定期检查仪器的连接线路,确保无松动或损坏。
四、故障排除以下为常见故障及解决方法,若出现其他故障,请联系本公司售后服务部门。
1. 仪表未正常启动解决方法:检查电源连接是否稳定,确保电源正常。
2. 数据显示不准确解决方法:检查传感器连接是否松动或者损坏,若有问题请更换新的传感器。
3. 仪表指示灯闪烁解决方法:重新启动仪器,并进行相关设置。
五、注意事项1. 请避免在高温、潮湿或者有腐蚀性物质的环境中使用仪器。
2. 请勿将仪器暴露在阳光直射下,以防损坏仪器外壳。
3. 请勿使用不合格的电源进行连接,在电源输入电压范围内使用。
4. 请妥善保管该说明书,以备日后查询和维修使用。
衷心祝愿您能够顺利使用本公司的精密仪器仪表,如有任何疑问或需要进一步帮助,请随时与我们联系。
D2008型 电子称重仪表 使用说明书
D2008型电子称重仪表使用说明书2018年3月版●使用前请仔细阅读本产品说明书●请妥善保管本产品说明书,以备查阅目录第一章技术参数 (1)第二章常规操作说明 (2)一、开机及开机自动置零 (2)二、手动置零 (2)三、去皮 (2)四、清皮 (2)五、日期与时间查询与设置 (2)第三章称重记录的储存与打印 (2)一.称重记录的储存 (2)二. 车号皮重的设置与清除方法: (3)三、车号皮重的批量查看与清除方法: (3)四. 称重记录的打印 (3)五. 明细报表打印 (4)六.称重记录的查询与清除 (4)七.称重记录和车号皮重的全部删除操作 (5)八.查询打印 (5)第四章信息提示 (5)附录 A:打印操作举例: (6)附录 B:明细表及统计报表示例 (7)▲仪表电源接地线必须符合电气安全规定,接线盒、传感器的外壳必须接地良好。
▲数字传感器与仪表的连接必须可靠,数字传感器的屏蔽线必须可靠接地。
▲在仪表通电状态下,所有连接线不允许进行插拔,防止静电和漏电损坏仪表或传感器。
▲传感器和仪表都是静电敏感设备,在使用中必须切实采取防静电措施。
▲在雷雨季节,系统必须落实可靠的避雷措施,防止因雷击造成传感器和仪表的损坏,确保操作人员的人身安全和称重设备及相关设备的安全运行。
▲不得在有可燃性气体或可燃性蒸汽的场合使用,不得在有压力的罐装系统中使用。
▲仪表和传感器须远离强电场强磁场,远离强腐蚀性物体,远离易燃易爆物品。
▲严禁使用强溶剂(如:苯、硝基类油)清洗机壳。
▲不得将液体或其他导电颗粒注入仪表内,以防仪表损坏和触电。
▲本产品非经技术监督部门授权,不得擅自开启铅封,不破坏铅封不能标定。
◆为保证仪表显示清晰和使用寿命,仪表不宜放在阳光直射下使用,放置地点应较平整。
◆仪表不宜放在粉尘及振动严重的地方使用,避免在潮湿的环境中使用。
◆在插拔仪表与外部设备连接线前,必须先切断仪表及相应设备电源。
◆仪表对外接口须严格按使用说明书中所标注的方法使用,不得擅自更改连接。
D2008型数字仪表说明书
D2008型电子称重仪表技术说明书2012年02月简化版●使用前请仔细阅读本产品说明书●请妥善保管本产品说明书,以备查阅宁波柯力传感科技股份有限公司目录第一章技术参数 (1)第二章秤台调试步骤指南 (1)第三章安装联接 (2)第一节、仪表与数字传感器的连接 (2)第二节、仪表与大屏幕的连接使用 (2)第三节、仪表与电脑的连接使用 (3)第四节、仪表与蓄电池的连接使用 (3)第四章数字传感器调试 (3)第一节修改传感器通信地址与秤台数字传感器组秤 (3)第二节修改数字传感器通讯角位 (4)第三节压角识别秤台各角位下的数传地址 (5)第四节查瞧各角位内码 (5)第五节角差修正 (5)第五章标定调试 (7)第一节标定 (7)第二节分度值自动切换与标定线性 (8)第三节标定误差的修正 (9)第六章其她操作 (9)第一节密码管理 (9)第二节日期时间设置 (10)第三节定时关机 (10)第三节系统测试 (11)第四节PC通讯参数设置 (12)第五节打印参数设置 (12)第六节自定义打印格式设置 (14)第七节仪表文本信息输入与文本信息删除 (14)第六章信息提示 (15)附录A: 通信协议 (15)附录B:称重单格式示例: (18)▲!传感器与仪表的连接必须可靠传感器的屏蔽线必须可靠接地插拔,防止静电损坏仪表或传感器。
▲!传感器与仪表都就是静电敏感设备, 在使用中必须切实采取防静电措施,严禁在秤台上进行电焊操作或其她强电操作,在雷雨季节,必须落实可靠的避雷措施,防止因雷击造成传感器与仪表的损坏,确保操作人员的人身安全与称重设备及相关设备的安全运行。
第一章技术参数1、型号:适用于D2008-F(A 、P、P1)不锈钢壳+橡胶按键、D2008-FB 不锈钢壳+金属按键、D2008-FJ不锈钢壳+橡胶按键D2009-FC(A、P、P1) 不锈钢壳+橡胶按键、D10(A、P1) 塑料壳+薄膜按键、D11、D11(P、P1) 与D11_B、D11_B(P、P1)塑料壳+薄膜按键2、数字传感器接口:通信方式RS485信号传输距离在接12数字传感器情况下可接至30米,如需更长,请与本公司联系传输波特率9600、19200 bps激励电源DC12V数字接口能力最多可接16个数字传感器3、显示: 7位LED数码管,7个状态指示符。
多功能数显表使用说明书
多功能电力监测仪使用手册版本:杭州正普科技有限公司使用前必读在您使用本产品之前,请务必仔细阅读此使用手册内容,正确按照用户手册指导操作,这会有助于您更好地使用本产品,并有助于解决现场出现的各种问题。
1、监测仪在施加工作电源之前,务必确保工作电源在仪表规定范围之内;2、现场安装使用时,电流输入端子严禁开路,电压输入端子严禁短路;3、通讯端子(RS485)严禁施加高压;4、使用时仪表接线方式务必与内部系统设置方式一致;5、与后台通讯时,仪表通讯参数务必与后台一致;不能带电拔插通信接口;6、本手册中的信息如有变动,恕不另行通知;我公司自始至终本着“质量第一服务第一”的宗旨,将以优质的产品、优良的服务奉献给国内外用户!●使用前请仔细阅读本用户使用手册●请注意妥善保存目录一、概述-------------------------------------------------- 1二、型号定义---------------------------------------------- 1三、尺寸对照表-------------------------------------------- 1四、型号与功能对照表-------------------------------------- 2五、技术指标---------------------------------------------- 3六、外形及安装尺寸---------------------------------------- 4七、接线图------------------------------------------------ 6八、操作说明----------------------------7(RS485通讯规约、CT/PT设置、开关量操作、变送输出操作)一、概述多功能电力监测仪具有对电网中电流、电压、频率、有功功率、无功功率、视在功率、电能、功率因数等进行同时测量的功能。
多功能电力仪表说明书
ACXE898B34多功能电力仪表永诺电气一、概述ACXE898B34多功能电力仪表是一种具有可编程测量、显示、数字通讯和电能脉冲变送输出等功能的多功能电力仪表,能够完成电量测量、电能计量、数据显示、采集及传输,可广泛应用变电站自动化,配电自动化、智能建筑、企业内部的电能测量、管理、考核。
测量精度为0.5级、实现LCD 现场显示和远程RS-485数字通讯接口,采用MODBUS-RTU通讯协议二、技术参数3.2 测量显示可测量电网中的电力参数有:Ua、Ub、Uc(相电压);Uab、Ubc、Uca(线电压)Ia、Ib、Ic(电流);Ps(总有功功率);Qs(总无功功率);PF(总功率因素);Ss(总视在功率);F(频率)以及EP(有功电能)、Eq(无功电能)所有的测量电量参数全部保存仪表内部的电量信息表中,通过仪表的数字通讯接口可访问采集这些数据。
而对于不同的型号的仪表,其显示内容和方式却可能不一致,请参考具体的说明。
所有的电量参数的计算方法采用如下公式的数字化的离散方法,具体为:其中P>0,累计的有功电能量是有功电能吸收,P<0,累计的有功电能是有功电能释放,Q>0,累计的无功电能是无功电能感性,Q<0,累计的无功电能是无功电能容性。
3.3 页面显示示意图多功能电力仪表共有16个电力参数显示页面,用户可设置为自动切换显示,也可设置为手动切换。
通过“”键来完成页面切换。
页面内容说明第一页面分别显示电压Ua、Ub、Uc (三相四线)和Uab、Ubc、Uca(三相三线)左图中Ua=100.0V Ub=100.1VUc=100.0V三相三线接线仪表显示线电压三相四线接线仪表显示相电压页面内容说明第二页面显示三相电流Ia,Ib,Ic单位为A。
左图中Ia=1.000AIb=1.001AIc=1.000A第三面显示总有功功率左图中PS=3.3KW第四页面显示各分相有功功率左图中:Pa=1.100KWPa=1.101KWPc=1.100KW第五页面显示总无功功率左图中:Qs=2.850Kvar第六页面显示A相无功功率左图中:Qb=1.100var页面内容说明第七页面显示B相无功功率左图中:Qb=1.099Kvar第八页面显示C相无功功率左图中:Qc=1.099Kvar第九页面显示总功率因数左图中:PF=L0.99表示总功率因数0.99感性第十页面显示各相功率因数左图中:PFa=0.99LPFb=0.99LPFc=0.98L第十一页面显示电网频率左图中:F=50Hz页面内容说明第十二页显示正向有功电能左图中:EP=1.124KWH第十三页显示反向有功电能左图中EP-=-0.104KWH第十四页显示正向无功电能左图中EQ=1.124Kvarh第十五页显示反向无功电能左图中EQ-=-1.004Kvarh第十六页显示总视在功率左图中:Ss=100.1VATX灯亮表示仪表正在与上位机进行数据交换3.6 编程菜单结构图用户可根据实际情况选择适当的编程设置参数:例1:电压变比调试(例:10KV/100V)例2:电流变比调试(例:250A/5A)四、数字通讯多功能电力仪表提供串行异步半工RS485通讯接口,采用MOD-BUS-RTU协议,各种数据信息均可在通讯线路上传送。
多功能数显表使用说明书
多功能电力监测仪使用手册版本:杭州正普科技有限公司使用前必读在您使用本产品之前,请务必仔细阅读此使用手册内容,正确按照用户手册指导操作,这会有助于您更好地使用本产品,并有助于解决现场出现的各种问题。
1、监测仪在施加工作电源之前,务必确保工作电源在仪表规定范围之内;2、现场安装使用时,电流输入端子严禁开路,电压输入端子严禁短路;3、通讯端子(RS485)严禁施加高压;4、使用时仪表接线方式务必与内部系统设置方式一致;5、与后台通讯时,仪表通讯参数务必与后台一致;不能带电拔插通信接口;6、本手册中的信息如有变动,恕不另行通知;我公司自始至终本着“质量第一服务第一”的宗旨,将以优质的产品、优良的服务奉献给国内外用户!●使用前请仔细阅读本用户使用手册●请注意妥善保存目录一、概述-------------------------------------------------- 1二、型号定义---------------------------------------------- 1三、尺寸对照表-------------------------------------------- 1四、型号与功能对照表-------------------------------------- 2五、技术指标---------------------------------------------- 3六、外形及安装尺寸---------------------------------------- 4七、接线图------------------------------------------------ 6八、操作说明----------------------------7(RS485通讯规约、CT/PT设置、开关量操作、变送输出操作)一、概述多功能电力监测仪具有对电网中电流、电压、频率、有功功率、无功功率、视在功率、电能、功率因数等进行同时测量的功能。
B系列数显表说明书2013
B系列数显表说明书2013智能数字显示报警仪操作说明书高性能数字显示报警仪使用说明(适用于2007年12月以后所生产的新产品)z 主要技术指标:1、显示范围:-1999~9999,小数点位置可设置。
2、测量及变送输出准确度:±0.2%F·S±1字;±0.1%F·S±1字(需特殊订制)。
3、输入信号:热电偶: K、E、S、B、J、T、R、WRe 系列等;冷端温度自动补偿范围0~50℃,补偿准确度±2℃。
热电阻:Pt100、Cu100、Cu50、BA2、BA1;引线电阻补偿范围≤15Ω。
直流电压:0~20mV、0~75mV、0~200mV、0~5V、1~5V;0~10V (订货时需指定,与其他信号不兼容)。
直流电流:0~10mA、0(4)~20mA 。
线性电阻:0~400Ω(远传压力表)。
4、模拟输入阻抗:电流信号Ri=100Ω;电压信号Ri=500kΩ。
5、模拟输出负载能力:电流信号:0(4)~20mA 输出时Ro≤500Ω;0~10mA 输出时Ro≤1kΩ。
电压信号:要求外接仪表的输入阻抗Ri≥250kΩ,否则不保证连接外部仪表后的输出准确度及线性度。
6、配电输出:DC24±2V、30mA,过流自动保护。
7、报警方式:单回路可对应四个报警点,双回路仪表每回路对应2个报警点。
8、通讯方式:RS232(10米)或RS485(1000米)9、使用环境:环境温度:-10℃~55℃,环境湿度:10%RH~90%RH。
10、耐压强度: 输入/输出/电源/通讯,≥1000V AC,1分钟。
11、绝缘阻抗: 输入/输出/电源/通讯,≥100MΩ。
12、电源:交流85~265V AC(或直流120~360V DC)。
直流16~28V DC。
13、功耗:<4W。
z 显示说明:单回路仪表单排数码管显示:在测量状态下显示当前测量值,参数设置状态下先显示参数代码,再显示参数值,性能描述z 更高的采样速度,高达100ms/次z 更高的抗干扰能力,EMC≥2000V z 更高的测量准确度,长期保证0.2% z 更低的温度漂移,≤50ppm z 更低的变送输出纹波,≤50mV p-p z 更高效的、高可靠的开关电源 zSMT 表贴工艺功能说明z 智能万用信号输入方式z 双回路仪表可分别独立设置输入信号种类 z 数字化设置报警点及线性输入量程 z 数字化的校准方式z 冷端温度及热电阻引线电阻自动补偿 z 隔离的变送输出方式,输出量程可设置 z采用标准MODBUS RTU 通讯协议即参数代码和参数值轮流显示。
LAB8000说明书范本(DOC 122页)
软件实验
1.存储器块清零(51/96/88/PIC).....................................................................21
2.二进制到BCD码转换(51/96/88/PIC).......................................................22
3.二进制到ASCII码转换(51/96/88/PIC).....................................................23
34. 8253计数器实验(88).........................................….........................................82
35. 8259外部中断实验(88)...........................................…...................................83
22.步进电机控制实验(51/96/88/PIC/ARM).......................................................62
23.温度传感器实验(51/96/88/ARM)...................................................................65
32.用片内A/D做模数转换实验(96).....................…........................................80
DL8000系列智能型数字显示温度控制仪表使用说明书
XY1000 IntelligentDigital Temp & Time ControllerRead these instructions carefully before use and keep for future reference.1. Product IDXY1000 (External solid-state relay output + buzzer)2. Technical Parameters•Power:AC220V/110V 50Hz/60Hz •Range:0-400℃ (K Thermocouple sensor) •Dimensions:86mm*87mm •Ambient Temperature:0℃-50℃•Control Mode:Intelligent PID Control •Accuracy:0.5%±1dig3. Panel Layout①PV: Shows the measured temp value or other promptmeter status display②SV: Shows the current set temp value or other value setdepending on instrument.Indicators•Autotune indication flashes at work. •Heating output•Timing•Adjust for control parameters or self-tuning execution•Adjust for control parameters or start the countdown•Enter/Confirm value , etc 。
4.Terminals5. 操作5.1控制模式功能说明• 仪表通电后,上排显示InP,下排字符分度号,表示温度传感器输入类型。
DS8000B使用说明书
第六章. 功率计
对连接外设型功率传感器时的 RF 功率测试方法和测试画面进行了说明。
第七章. 保存和加载
保存测试结果,调用及分析已保存的结果。
第八章. 数据分析软件
(随厂家版本更新)
第九章. 附录
记载了 DS8000B 的波段列表, 电缆列表和详细规格。
Rev 1.1
4
DS8000B 天馈线测试仪
DS8000B 天馈线测试仪用户手册
Copyright 2007-2008 INNO Instrument Inc.
DS8000B 天馈线测试仪
用户手册
每次改善功能时,本文件内容可以随时变更,并不另行通知
安全指南
1.2 安全指南
安全记号
以下是与安全相关的记号;使用本设备之前,必须要熟悉掌握各种安全记号。
Rev 1.1
警告 ‘警告’记号代表致命危险;如果没有严格依照手册中的指示内容,可能会给用户造成严 重的损伤。
注意 如果没有严格依照手册中的指示内容,可能会给设备造成严重的损伤。
!
提示 为了用户的便利,向设备用户提示附加使用信息或者指南。
安全注意事项
该产品是安全等级为Ⅰ级的设备,连接电源时,主电源插头必须要连接到设有接地装置的插 座上。
2.2 固定按键的布局 ................................................................... 16 2.3 用户界面的构成 ................................................................... 18 2.4 不同功能键的构成 ................................................................. 19
D800W通用测力仪表使用手册
D800W通用测力仪表使用手册
1、取下电池盖板,安装9V叠层电池,按正负极接牢,然后合上电池盖板。
调整好握把距离,准备测量握力。
2、按下开关键开机,释放按键后,仪器显示0.0,即可进入状态。
3、受试者用力握把,此时液晶显示屏上的数据开始刷新显示,直至不再有新的测量峰值出现为止,即可读取测量数据。
4、当显示器显示不为0时,按下清零键即可清除当前测量数据,准备下一次握力测量。
注意,在清零时不可施加任何握力,否则,测量数据将会不准。
5、当3分钟无任何操作时,仪器将自动关机。
日本安立、美国BLRD使用说明书(天馈线测试仪)
第四章天馈线测试仪作用:用于开馈线系统的性能测试。
主要功能:测试开馈的驻波比/回损(SWR/RL)stanging wave ratio/return loss;故障点定位(DTF)Distance-to-fault;射频功率(RF Power)测试需要增加功率测试模块;频谱分析功能(S332系列);适用范围:适用于测量GSM900与DCS1800。
天馈线测试仪产品现市场的主流天馈线测试仪产品:1、日本安立1Site Master相关产品:S251和S3312、美国BLRDSite Analyzer相关产品:SA2500和SA4000日本安立Site Master简介区别:1.各系列的频率范围:S331:25~4000MHzS251:625~2500MHz2.测试功能:除了频率范围不同,S331是单端口测试仪,而S251是双端口的,增加了测天线隔离度功能(少用)日本安立-Site Master S331外观图(见170页)日本安立-Site Master S331按键图(见171页)SLTE MASTER S331主要配件1.5米测试电缆一条校准连接器一个(short/open/load)或快速校准件PC工具软件充电器(AC—DC)一个?N型(m)7/8D型(f)馈线转接器DB9数据连接线一条(用于与PC相连)常规测试内容驻波比测试:测试馈线质量如何故障点定位:测试馈线是否折断或进水操作步骤:1. 开机2. 初始设配1) 设定频率范围(F):即频率的上下限;以GSM900为例:设上限为960MHz。
下限为890MHz;--先按FRFQ软键。
--然后按F1软键。
--输入天线系统的下限(Lower)频率890MHz值,按ENTE键。
按F1软键--输入天线系统的下限(Lowe)频率MHz值,按ENTER键。
--再按F2软键。
--输入天线系统的上限(Higher)频率MHz值,按ENTER键。
--在显示区域显示新的开始与结束值的地方检查频率值范围FREQ --按MALN软键进入主菜单。
BOD测试仪说明书
3.1 测量范围:0mg/L~1000mg/L(BOD5 值超过测量范围时需要稀释) 3.2 同时测定样品数:每次 8 份样品 3.3 准确度:符合国标“GB7488-87”规定
(葡萄糖谷氨酸标液 BOD5 值在 180mg/L~230mg/L 范围内) 3.4 显示:三位半数码显示器 3.5 培养温度:20℃±1℃ 3.6 电源:AC 220V±22V,50Hz±0.5Hz 3.7 功耗:约 300W(含它带动培养瓶内的搅拌子,对待测样品 进行搅拌,以促进培养瓶空气中的氧气溶解于样品液中。
5.2.3 BOD 培养瓶:样品放人培养瓶中进行生化培养,该培养瓶经过特殊处理,各台仪 器之间不能互换,更不能用其它类似的瓶子代替。
5.2.4 遥控器:红外线遥控器专用于选通 8 路测量通道。使用遥控时不需要打开玻璃门 就可读取 BOD 数据,可保证培养温度的恒定,若遥控器失灵可用“手动键”。
将仪器放入培养箱内,按预先选择的量程,量取一定体积的水样倒入培养瓶中,并将 培养瓶连接好放在仪器上连续搅拌。培养箱温度控制在 20℃±1℃,培养瓶中必须保证足 够的溶解氧,水样恒温后进行五日培养。样品中的有机物经过生物氧化作用,转变成氮、
碳和硫的氧化物,在这一过程中,从水样中跑出来的唯一气体二氧化碳被氢氧化钠(或氢 氧化钾)吸收。因此,瓶中空气压力减少量,相当于微生物所消耗的溶解氧量,样品 BOD 值与瓶中空气压力减少的数量成正比,通过测量空气压力的变化可以得到 BOD 值。增加或 减少所取样品的量可以增加或降低压力减少值。这样操作者无须繁杂的稀释步骤就能准确 测量很宽范围的 BOD 值。培养瓶中空气压力的变化通过半导体压力传感器进行检测,由数 码显示器显示出被测样品的 BOD 值。
2.1 B0D5 基本原理.................................................................................................................................... 3 2.2 测定原理............................................................................................................................................3 三、 主要技术指标.....................................................................................................................................4 四、 仪器的组成.........................................................................................................................................4 五、 安装和使用.........................................................................................................................................4 5.1 环境条件............................................................................................................................................4 5.2 功能部件说明....................................................................................................................................4 5.3 首次使用......................................................................................................... 错误!未定义书签。 5.4 检查步骤......................................................................................................... 错误!未定义书签。 六、 分析方法及分析步骤...................................................................................... 错误!未定义书签。 6.1 四种无机盐的制备......................................................................................... 错误!未定义书签。 6.2 稀释水的制备................................................................................................. 错误!未定义书签。 6.3 实际样品 BOD5 的测量.....................................................................................错误!未定义书签。 6.4 测定数据处理:............................................................................................. 错误!未定义书签。 6.5 标准样品的 BOD5 试验方法............................................................................ 错误!未定义书签。 6.6 影响 BOD5 测定的因素.....................................................................................错误!未定义书签。 6.7 稀释................................................................................................................. 错误!未定义书签。 6.8 接种................................................................................................................. 错误!未定义书签。 6.9 接种方法......................................................................................................... 错误!未定义书签。 七、 正常维护和常见故障的排除.......................................................................... 错误!未定义书签。 八、 运输和贮存...................................................................................................... 错误!未定义书签。 九、 注意事项.......................................................................................................... 错误!未定义书签。 十、 JC-880 型数字式 BOD5 测定仪装箱清单...................................................... 错误!未定义书签。
UNI800 称重仪表手册
3-1 安装注意事项 ..............................................................................................................................................8 3-2 称重显示器输入灵敏度...............................................................................................................................8 3-3 传感器与显示器之连接法...........................................................................................................................8 3-4 称重终端最长可联接的称重信号电缆长度表 ...........................................................................................9 3-5 称重传感器接线方式...................................................................................................................................9 3-6 安装尺寸图(单位:MM) .......................................................................................................................10
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
BLD800多功能复费率谐波仪表(LCD版)技术说明书(2012.05.V2.0版)河南保联电气有限公司目录一、概述 (1)二、技术参数 (1)2.1辅助电源 (2)2.2输入信号 (2)三、编程和使用 (2)3.1按键定义 (2)3.2测量显示…………………………………………………………………2-33.3 页面显示示意图……………………………………………………………………3-73.4编程操作 (8)3.5菜单组织结构图 (9)3.6编程菜单结构图 (10)调试举例图…………………………………………………………………………11-14四、数字通讯 (15)4.1 报文格式指令………………………………………………………………16-194.2脉冲输出 (20)4 .3 开关量输入 (20)4 .4开关量输出 (21)开关量输出对照表 (22)4. 5变送输出 (23)变送输出对照表……………………………………………………………………24-25 M O D B U S-R T U通讯地址信息表………………………………………………26-31五、接线图 (32)42 方型接线图 (32)96方型接线图 (33)80方型接线图 (34)六、常见问题及解决方案 (35)BLD800多功能复费率谐波仪表--用户手册一、概述BLD800多功能复费率谐波仪表是一种具有可编程功能、自动化测量、液晶显示、电能累加、数字通讯等多功能为一体的智能三相综合电力参数监测仪表。
它集数字化、智能化、网络化于一身,使测量过程及数据分析处理实现自动化,减少人为失误,能够全面代替电量变送器、电度表、数显仪表、数据采集器等仪器,是组成电气自动化系统的理想产品。
其结构紧凑、电路先进、测量功能强大,是对传统仪表的革命性设计。
BLD800多功能复费率谐波仪表广泛应用电力、邮电、石化、煤炭、冶金、铁道、市政、智能大厦等行业、部门的电气装置、自动控制、调度系统以及能效管理系统。
数值电度从0开始计数其中P>0,累计的有功电能量是有功电能吸收,P<0,累计的有功电能是有功电能释放,Q>0,累计的无功电能是无功电能感性,Q<0,累计的无功电能是无功电能容性。
|3.3 页面显示示意图:网络多功能电力仪表共有14个电力参数显示页面,用户可设置为自动切换显示,也可设置为手动切换。
通过“”键来完成页面切换。
页面内容说明第一页面分别显示电压Ua、Ub、Uc (三相四线)和Uab、Ubc、Uca(三相三线)左图中Ua=326.70V Ub=326.71VUc=326.70V EP=6.020kWh三相三线接线仪表显示线电压三相四线接线仪表显示相电压有功电能、无功电能四象限显示。
开关量输入(DI)、开关量输出(DO)4个按键用于显示切换或编程设置,“”“”为切换键:“”为上退键,“”为选择确认键。
对应的测量项目:分别为三相电压;三相电流;有功功率、无功功率、视在功率;有功电能、无功电能、功率因素、频率、电压总谐波含量、电流总谐含量、电压不平衡度、电流不平衡度、漏电流、分相有功功率、分相无功功率、分相功率因素信息。
页面内容说明第二页面显示三相电流Ia,Ib,Ic单位为A。
左图中Ia=18.770AIb=18.771AIc=18.770AEP=-0.668kWh第三页面显示有功功率(W)、无功功率(var)、视在功率(VA)。
左图中PS=2.4553KWQS=4.2476KVarSS=4.9059KVAEQ=5.44MVarh第四页面显示视在功率因素(PF)、频率(F)。
左图中:第1排:功率因素为L0.5;第2排:频率为50.00Hz EQ=-5MVarh第五页面显示A、B、C三相有功功率。
左图中Pa=8164WPb=8187WPc=8200WEp=-0.668KWh页面类容说明第六页面显示A、B、C三相无功功率。
左图中Qa=1.4149kvarQb=1.4159kvarQc=1.4166kvarEQ=5.44Mvarh第七页面显示A、B、C三相功率因素。
左图中PFa=0.449PFb=0.5PFc=0.499EQ=-5Mvarh第八页面显示A、B、C各相电压总谐波含量。
Ep=6.02KWh第九页面显示A、B、C各相电流总谐波含量。
EQ=-0.668KWh页面类容说明第十页面显示三相电压总不平衡度。
左图显示电压不平衡度为:0.15%。
EQ=5.44Mvarh第十一页面显示三相电流总不平衡度。
左图显示电流不平衡度为:0.02%。
EQ=-5Mvarh第十二页面显示漏电流或零线电流。
左图显示漏电流为:0.014A。
EQ=6.02Mvarh(此功能只限96*96外形)第十三页面显示最大电压、电流需量(每五分钟采集一次数值)。
左图中Umax=220.5VImax=4.863AEp=1.132kWh页 面 内 容 说 明第十四页面显示最大有功功率、无功功率需量(每五分钟采集一次数值)。
左图中Pmax=3174W Qmax=2508var Ep=-1.362kWh3.4、编程操作在编程操作下,仪表提供了:密码验证和修改(CODE)、系统设置(SET )、显示设置(DIS )、通讯设置(CONN )四个基本菜单项目,使用LED 显示的分层菜单结构管理方式:第1排LCD 显示第1层菜单信息;第2排LCD 显示第2层菜单信息,第3排LCD 提供第三层菜单信息。
键盘的编程操作采用四个按键的操作方式,即:左右移动键“”、“”、菜单回退键“”、菜单进入/确定键“” 来完成上述功能的所有操作。
:如果当前正常显示是电压界面,按该键进入编程模式;在编程模式,按该键退回上级菜单,如果当前是第1级菜单,按该键进入参数保存界面,再按则取消保存,退回正常显示界面;:切换移动键,实现菜单项目的切换或者数字量的增加或减少。
:选择/确认键,如果当前正常显示是电压界面,按该键可以切换“相电压/线电压”;在编程模式,按该键进入下一级菜单,设置时控制光标移到下一字符或者菜单中下一层选项。
在编程方式退回到测量模式的情况下,仪表会提示“SAVE-YES ”,选择“” 表示不保存退出,选择“” 保存退出采用分层结构管理的菜单的方式,图中编程项目即:(左图所示) 第一层:SEt (参数设置) 第二层:nEt (接线制式) 第三层:n.3.4(三相四线)3.5、漏电流检测说明:(此功能只限96*96外形)3.5.1、显示界面如图:3.5.2功能说明:剩余电流检测部分,包括零序电流互感器ZCT和测量回路,零序电流电感检测。
当零序电流互感器ZCT检测到用电线路中有超过限值(可根据需要在3mA至500mA之间设定)的剩余电流存在时,通过显示界面显示电路中剩余电流,已经通过485通信接口,用MODBUS协议上传漏电数据,供电部门就能对线路故障进行及时维护。
还能通过多路控制节点,用于报警、跳闸等控制。
3.5.3、内部零序电流互感器接线说明:正常情况下,Ia,Ib,Ic三个电流的矢量和等于零线电流In(Ia+Ib+Ic=In),但方向相反,这样就相互抵消,零序流互感器检测电流为Id=0,如下图所示但如果负载或电线有漏电,即零序电流In<Ia+Ib+Ic,这是漏电流检测互感器就能检测到有漏电流流过,漏电流大小为:Id=(Ia+Ib+Ic)-In.3.6菜单的组织结构如下:用户可根据实际情况选择适当的编程设置参数。
3.7 编程菜单结构图用户可根据实际情况选择适当的编程设置参数:注:退出菜单设定,出现SAVG YES时;按键为保存退出,按键为无效退出。
例1:电压变比调试(例:10KV/100V)例2:电流变比调试(例:250A/5A)例3:模拟量变送输出设置(例:设定AO1;B相电压0-220V输出模拟信号4-20mA)例4:报警输出设置(例:设定DO1,B相电压高限于200V)四、数字通讯多功能复费率谐波电力仪表提供串行异步半工RS485通讯接口,采用MODBUS-RTU协议,各种数据信息均可在通讯线路上传送。
在一条485总线上可以同时连接多达32个仪表,每个仪表均可以设定其通讯地址(Address NO.),不同系列仪表的通讯接线端子号码可能不同,通讯连接应使用带有铜网的的屏蔽双绞线,线径不小于0.5mm2。
布线时应使用通讯线远离强电电缆或其他强电场环境,推荐采用T型网络的连接方式。
不建议采用星形或其他的连接方式。
MODBUS/RTU通讯协议:MODBUS协议在一根通讯线上采用主从应答方式的通讯连接方式。
首先,主计算机的信号寻址到一台唯一地址的终端设备(从机),然后,终端设备发出的应答信号以相反的方向传输给主机,即在一根单独的通讯线上信号沿着相反的两个方向传输所有的通讯数据流(半双工的工作模式)。
MODBUS协议只允许在主机(PC,PLC等)和终端设备之间通讯,而不允许独立的终端设备之间的数据交换,这样各终端设备不会在它们初始化时占据通讯线路,而仅限于响应到达本机的查询信号。
主机查询:查询消息帧包括设备地址码、功能码、数据信息码、校验码。
地址码表明要选中的从机设备功能代码告之被选中的从设备要执行何种功能,例如功能代码03或04是要求从设备读寄存器并返回它们的内容;数据段包含了从设备要执行功能的其它附加信息,如在读命令中,数据段的附加信息有从何寄存器开始读的寄存器数量;校验码用来检验一帧信息的正确性,为从设备提供了一种验证消息内容是否正确的方法,它采用CRC16的校准规则。
从机响应:如果从设备产生一正常的回应,在回应消息中有从机地址码、功能代码、数据信息码和CRC16校验码。
数据信息码包括了从设备收集的数据:如寄存器值或状态。
如果有错误发生,我们约定是从机不进行响应。
传输方式是指一个数据帧内一系列独立的数据结构以及用于传输数据的有限规则,下面定义了与MODBUS协议-RTU方式相兼容的传输方式。
每个字节的位:1个起始位、8个数据位、(奇偶校验位)、1个停止位(有奇偶校验位时)或2个停止位(无奇偶校验位时)。
地址码:是帧开始的部分,由一个字节(8位二进制码)组成,十进制为0~255,在我们的系统只使用1~247,其它地址保留。
这些位标明了用户指定的终端设备的地址,该设备将接受来自与之相连的主机数据。
每个终端设备的地址必须是唯一的,仅仅被寻址到的终端会响应包含了该地址的查询,当终端发送回一个响应,响应中的从机地址数据告诉了主机那台终端与之进行通信数据码:包含了终端执行特定功能所需要的数据或者终端响应查询时采集到的数据。
这些数据的内容可能是数值、参考地址或者设置值。
例如:功能域码告诉终端读取一个寄存器,数据域则需要反映明从哪个寄存器开始及读取多少个数据,而从机数据码回送内容则包含了数据长度和相应的数据。