5600说明书

合集下载

NPort 5600 系列驱动程序和管理套件发布说明书

NPort 5600 系列驱动程序和管理套件发布说明书

Driver for NPort 5600 Series (NPort Administration Suite) ReleaseNotesSupported Operating SystemsNotesChangesApplicable ProductsBugs FixedN/A• Driver signature failure on Windows 7.• Unable to reopen the Grouped-COM port for IP Serial library.• BSOD issue when a Grouped-COM port is opened.• Cannot import encrypted configuration files via the web console.EnhancementsWindows 10, Windows 7, Windows 8, Windows 8.1, Windows Server 2008 R2, Windows Server 2012,Windows Server 2012 R2, Windows Server 2016, Windows Server 2019NPort 5000AI-M12 Series, NPort 5100 Series, NPort 5200 Series, NPort 5400 Series, NPort 5600Series, NPort 5600-DT Series, NPort 5600-DTL Series, NPort 5100A Series, NPort 5200A Series,NPort P5150A Series, NPort IA5000 Series, NPort IA5000A Series• Supports Windows Server 2019.• Supports Moxa Security Guidelines.New Features• Driver version 2.0: Windows 95/98/ME/NT/XP/Vista and Windows Server 2003/2008; Driver version 3.0: Windows 7/8/8.1/10 and Windows Server 2008 R2/2012/2012 R2/2016/2019.N/ASupported Operating SystemsNotesChangesApplicable ProductsBugs FixedN/AN/AEnhancementsWindows 10, Windows 2000, Windows 7, Windows 8, Windows 8.1, Windows 95, Windows 98,Windows ME, Windows NT, Windows Server 2003, Windows Server 2008, Windows Server 2008 R2,Windows Server 2012, Windows Server 2012 R2, Windows Vista, Windows XPIndustrial Device Servers, NPort 5100 Series, NPort 5100A Series, NPort 5200 Series, NPort 5200A Series, NPort 5400 Series, NPort 5600 Series, NPort 5600-DT Series, NPort 5600-DTL Series • Supports encrypted configuration.New FeaturesN/A• This version also applies to models NPort IA-5250ISupported Operating SystemsNotesChangesApplicable ProductsBugs FixedN/A• Device search failure when the host has more than 16 IP addresses.• NPort Administration Suite could not be run on Windows 2000.EnhancementsWindows 10, Windows 2000, Windows 7, Windows 8, Windows 8.1, Windows 95, Windows 98,Windows ME, Windows NT, Windows Server 2003, Windows Server 2008, Windows Server 2008 R2,Windows Server 2012, Windows Server 2012 R2, Windows Vista, Windows XPIndustrial Device Servers, NPort 5100 Series, NPort 5100A Series, NPort 5200 Series, NPort 5200A Series, NPort 5400 Series, NPort 5600 Series, NPort 5600-DT Series, NPort 5600-DTL Series • Supports Windows 10.New FeaturesN/A• This version also applies to models NPort IA-5250ISupported Operating SystemsNotesChangesApplicable ProductsBugs FixedN/A• Updated IPSerial.dll to fix thread handle always existing.• Utility could not monitor devices with "auto save device" setting when restarting the utility.• Utility could not monitor devices with "manual" setting before executing search function.• Ports mapped by the NPort Administration Suite v1.18 or earlier would disappear when using a version of Administration Suite later than v1.18.• Searching by 802.11 WLAN would fail on Windows 7 or later.• The timeout of IPSerial nsio_checkalive function would not work on Windows 7 Ultimate.• Popup error message "The network component is not ready" when searching for an NPort on Windows 8.• Ports could not be sorted by COM number order when clicking the COM number field in the monitor page.• The ports mapped by NPort Administration Suite v1.19 or earlier could not be opened by using a version of Administration Suite later than v1.19.17.EnhancementsWindows 2000, Windows 7, Windows 8, Windows 8.1, Windows 95, Windows 98, Windows ME,Windows NT, Windows Server 2003, Windows Server 2008, Windows Server 2008 R2, Windows Server 2012, Windows Server 2012 R2, Windows Vista, Windows XPIndustrial Device Servers, NPort 5100 Series, NPort 5100A Series, NPort 5200 Series, NPort 5200A Series, NPort 5400 Series, NPort 5600 Series, NPort 5600-DT Series, NPort 5600-DTL Series • IPSerial.dll upgraded to version 1.7.3.• IPSerial added example code for VB2010.• Updated NPort.dll to support NPort P5150A.New FeaturesN/A• This version also applies to models NPort IA-5250ISupported Operating SystemsNotesChangesApplicable ProductsBugs FixedN/AN/AEnhancementsWindows 2000, Windows 7, Windows 8, Windows 95, Windows 98, Windows ME, Windows NT,Windows Server 2003, Windows Server 2008, Windows Server 2008 R2, Windows Server 2012,Windows Vista, Windows XPIndustrial Device Servers, NPort 5100 Series, NPort 5100A Series, NPort 5200 Series, NPort 5200A Series, NPort 5400 Series, NPort 5600 Series, NPort 5600-DT Series, NPort 5600-DTL Series • Supports Windows 8 and Windows Server 2012.• Supports "Always Accept Open Request" for Windows 2000 and newer.New FeaturesN/A• This version also applies to models NPort IA-5250ISupported Operating SystemsNotesChangesApplicable ProductsBugs FixedN/A• Driver caused a BSOD when opening and closing repeatedly in Windows 2008 R2.• Driver caused a BSOD when applications open grouped COM ports which contain one or more disabled ports.• In the COM Grouping function, sometimes HyperTerminal may not read the received data immediately.EnhancementsWindows 2000, Windows 7, Windows 95, Windows 98, Windows ME, Windows NT, Windows Server 2003, Windows Server 2008, Windows Server 2008 R2, Windows Vista, Windows XPIndustrial Device Servers, NPort 5100 Series, NPort 5100A Series, NPort 5200 Series, NPort 5200A Series, NPort 5400 Series, NPort 5600 Series, NPort 5600-DT Series, NPort 5600-DTL Series • Supports NPort 5150AI-M12, 5250AI-M12, 5450AI-M12.• Supports LLDP configuration.• Supports Windows publish.New FeaturesN/A• This version also applies to models NPort IA-5250ISupported Operating SystemsNotesChangesApplicable ProductsBugs FixedN/A• Application will not work properly when logging as a standard user in Windows Vista/7environments. This version will prompt the user change to an account with administrative rights.• Windows 2008 64-bit driver would cause a BSOD when accessing an invalid memory path.• Modified the Georgetown time zone to GMT-04:00, Caracas to GMT-04:30, and Sofia to GMT +02:00.• The "nsio_RTS" function was not able to control RTS signals.EnhancementsWindows 2000, Windows 7, Windows 95, Windows 98, Windows ME, Windows NT, Windows Server 2003, Windows Server 2008, Windows Server 2008 R2, Windows Vista, Windows XPIndustrial Device Servers, NPort 5100 Series, NPort 5100A Series, NPort 5200 Series, NPort 5200A Series, NPort 5400 Series, NPort 5600 Series, NPort 5600-DT Series, NPort 5600-DTL Series • Supports NPort P5150A.New FeaturesN/A• This version also applies to models NPort IA-5250ISupported Operating SystemsNotesChangesApplicable ProductsBugs FixedN/A• System BSOD when setting and enabling COM grouping functions in Windows 2008 R2.EnhancementsWindows 2000, Windows 7, Windows 95, Windows 98, Windows ME, Windows NT, Windows Server 2003, Windows Server 2008, Windows Server 2008 R2, Windows Vista, Windows XPIndustrial Device Servers, NPort 5100 Series, NPort 5100A Series, NPort 5200 Series, NPort 5200A Series, NPort 5400 Series, NPort 5600 Series, NPort 5600-DT Series, NPort 5600-DTL Series • Supports NPort 5600-8-DTL Series.• Supports NPort A Series products in NPort.dll library.New FeaturesN/A• This version also applies to models NPort IA-5250ISupported Operating SystemsNotesChangesApplicable ProductsBugs FixedN/A• Reduced handle counts when application called nsio_init() from IPSerial library.• When closing COM port and applying change to other COM numbers simultaneously, the NPort administrator utility will cause a hang up.• If the nsio_close() function is called several times and then the nsio_open() function is called, it will fail and return an undefined error code.EnhancementsWindows 2000, Windows 7, Windows 95, Windows 98, Windows ME, Windows NT, Windows Server 2003, Windows Server 2008, Windows Server 2008 R2, Windows Vista, Windows XPIndustrial Device Servers, NPort 5100 Series, NPort 5100A Series, NPort 5200 Series, NPort 5200A Series, NPort 5400 Series, NPort 5600 Series, NPort 5600-DT Series, NPort 5600-DTL Series • Supports Multi-connection by IPSerial library.• Supports Windows 7.New FeaturesN/A• This version also applies to models NPort IA-5250ISupported Operating SystemsNotesChangesApplicable ProductsBugs FixedN/A• Shortened opening time for COM Grouping.• Shortened setting time for COM Grouping.• Write operation would stop transmitting.• Monitor and port monitor would stop after removing target.EnhancementsWindows 2000, Windows 7, Windows 95, Windows 98, Windows ME, Windows NT, Windows Server 2003, Windows Server 2008, Windows Vista, Windows XPIndustrial Device Servers, NPort 5100 Series, NPort 5100A Series, NPort 5200 Series, NPort 5200A Series, NPort 5400 Series, NPort 5600 Series, NPort 5600-DT Series, NPort 5600-DTL Series • Supports COM Grouping function for Windows NT.New FeaturesN/A• This version also applies to models NPort IA-5250ISupported Operating SystemsNotesChangesApplicable ProductsBugs FixedN/A• Set IP filter netmask error on Windows x64 platforms.EnhancementsWindows 2000, Windows 95, Windows 98, Windows ME, Windows NT, Windows Server 2003,Windows Server 2008, Windows Vista, Windows XPIndustrial Device Servers, NPort 5100 Series, NPort 5100A Series, NPort 5200 Series, NPort 5200A Series, NPort 5400 Series, NPort 5600 Series, NPort 5600-DT Series, NPort 5600-DTL Series • Supports NPort 5110A, 5130A, 5150A, IA5450A, IA5450AI, IA5150A, IA5150AI, IA5250A, IA5250AI,5210A, 5230A, 5250A.• Supports COM Grouping function (does not support Windows 95/98/ME/NT).New FeaturesN/A• This version also applies to models NPort IA-5250ISupported Operating SystemsNotesChangesApplicable ProductsBugs FixedN/A• "Import COM Mapping" function would throw an "invalid pointer opertion" message.• Monitor function would cause a memory leak.• Adjusted the IRP completion order for multi-processor environments.• Fixed the buffer protection mechanism for issues while inserting special characters in the serial RX buffer.EnhancementsWindows 2000, Windows 95, Windows 98, Windows ME, Windows NT, Windows Server 2003,Windows Server 2008, Windows Vista, Windows XPIndustrial Device Servers, NPort 5100 Series, NPort 5100A Series, NPort 5200 Series, NPort 5200A Series, NPort 5400 Series, NPort 5600 Series, NPort 5600-DT Series, NPort 5600-DTL Series • Supports NPort IA-5250I.New FeaturesN/A• This version also applies to models NPort IA-5250ISupported Operating SystemsNotesChangesApplicable ProductsBugs Fixed• Upgraded package: IPSerial Library.• Application crash problem with IP serial library when binding more than 8 IPs(alias) for PC.• Loading driver failed in Windows Vista x64.EnhancementsWindows 2000, Windows 95, Windows 98, Windows ME, Windows NT, Windows Server 2003,Windows Server 2008, Windows Vista, Windows XPIndustrial Device Servers, NPort 5100 Series, NPort 5100A Series, NPort 5200 Series, NPort 5200A Series, NPort 5400 Series, NPort 5600 Series, NPort 5600-DT Series, NPort 5600-DTL Series N/ANew FeaturesN/AN/ASupported Operating SystemsNotesChangesApplicable ProductsBugs FixedN/A• SERIAL_PURGE_TXABORT did not reset the WriteCharsQueued counter.• SIO outqueue count was inaccurate under classic mode.• The port number was incorrect in the "UDP Mode Settings: Destination" list.• Startup of Monitor and Port Monitor may fail.• Removal of Monitor and Port Monitor may fail.• The search function would have issues on a Windows 2003 host with dual LAN cards.• Adding COM port would fail if "SERIALCOMM" registry key was absent.• Invalid argument for time encode.• Access violation problem in "IP Address Report List".• Search function supports 16 IP addresses for local host.• "Alive" status in Monitor and Port Monitor may be incorrect.EnhancementsWindows 2000, Windows 95, Windows 98, Windows ME, Windows NT, Windows Server 2003,Windows Vista, Windows XPIndustrial Device Servers, NPort 5100 Series, NPort 5100A Series, NPort 5200 Series, NPort 5200A Series, NPort 5400 Series, NPort 5600 Series, NPort 5600-DT Series, NPort 5600-DTL Series N/ANew FeaturesN/AN/ASupported Operating SystemsNotesChangesApplicable ProductsBugs FixedN/AN/AEnhancementsWindows 2000, Windows 95, Windows 98, Windows ME, Windows NT, Windows Server 2003,Windows Vista, Windows XPIndustrial Device Servers, NPort 5100 Series, NPort 5100A Series, NPort 5200 Series, NPort 5200A Series, NPort 5400 Series, NPort 5600 Series, NPort 5600-DT Series, NPort 5600-DTL Series • Supports Windows Vista.• Supports 5610-8-DT, 5610-8-DT-J, 5650-8-DT, 5650-8-DT-J and 5650I-8-DT.New FeaturesN/AN/ASupported Operating SystemsNotesChangesApplicable ProductsBugs Fixed• Improved IoctlGetCommstatus() to report live out queue count.• Improved utility user interface.• Improved COM setting functions. If the selected ports are in use, no change can be made to them.These settings include: COM number, Tx mode, FIFO, and Fast Flush.• Improved COM setting functions. If the users do not have administrative privileges, they cannot add or delete COM ports. However, they can still view the COM settings and open the COM ports.• Improved utility user interface.• Modem dial out caused system halt on multi-processor platforms.• Driver read operations caused double completion (BSOD) on multi-processor platforms.• GetCommStatus caused a BSOD on multi-processor platforms.• ioctl of setting Xon/Xoff character failed.• Fixed bugs detected by Static Driver Verifier, which include a double completion problem and completion of IRP without releasing the cancel spinlock.• FastFlush setting error when COM port number exceeds 127.• COM Mapping problem when a disabled port is opened.EnhancementsWindows 2000, Windows 95, Windows 98, Windows ME, Windows NT, Windows Server 2003,Windows XPIndustrial Device Servers, NPort 5100 Series, NPort 5100A Series, NPort 5200 Series, NPort 5200A Series, NPort 5400 Series, NPort 5600 Series, NPort 5600-DT Series, NPort 5600-DTL Series • Added "Network Timeout" function for COM settings.• Added auto message log function.New FeaturesN/AN/ASupported Operating SystemsNotesChangesApplicable ProductsBugs FixedN/A• IOCTL_SERIAL_IMMEDIATE_CHAR bug causing a BSOD.• IOCTL_SERIAL_XOFF_COUNTER bug causing system halt.• Accessible IPs export and import configurations did not match.• IOCTL_SERIAL_IMMEDIATE_CHAR bug causing a BSOD.• IPSerial nsio_write and mutli-port connection problems.• Administrator could not remove serial port settings when uninstalling the NPort Administration Suite.• COM Mapping could not import files exported by Administrator v1.2.• Disconnecting an NPort will crash the application while calling nsio_close.EnhancementsWindows 2000, Windows 95, Windows 98, Windows ME, Windows NT, Windows Server 2003,Windows XPIndustrial Device Servers, NPort 5100 Series, NPort 5100A Series, NPort 5200 Series, NPort 5200A Series, NPort 5400 Series, NPort 5600 Series, NPort 5600-DT Series, NPort 5600-DTL Series • Supports PPP Mode and Real COM Mode (RFC2217) operating mode for NPort 56xx.• Supports 64-bit Windows.• Moved nprcmisic.dll to nport.dll to cover all NPort models.• Supports NPort 5130, 5150, 5650, 5650-S-SC, 5650-M-SC.• Supports SERIAL_LSRMST_ESCAPE and SERIAL_LSRMST_MST event types of IOCTL_SERIAL_LSRMST_INSERT requests. SERIAL_LSRMST_LSR_NODATA and SERIAL_LSRMST_LSR_DATA event types are not supported due to driver limitations.New FeaturesN/AN/ASupported Operating SystemsNotesChangesApplicable ProductsBugs Fixed• Improved Windows 2000/XP/2003 driver "Fast Flush" performance.• Improved disconnection process to prevent application blocking.• Improved NT/2000/XP/2003 driver Ioctl performance (parity, baud, modem...).• High CPU loading with Hyper Threading systems.• COM Mapping rescan prevents some models from being able to be configured.• Port Monitor: When NPort is reconnecting, Administrator increases CPU load to 100%.• Event log lost problem.• IOCTL_SERIAL_SET_WAIT_MASK (npser+114c) BSOD RQL_NOT_LESS_OR_EQUAL problem.• (npser+5c13) BSOD KERNEL_MODE_EXCEPTION_NOT_HANDLED problem.• Verifier testing problem.• Classic mode oqueue length was not correct.• Tx does not stop on network disconnection.• Write blocked after reconnecting.EnhancementsN/AIndustrial Device Servers, NPort 5100 Series, NPort 5100A Series, NPort 5200 Series, NPort 5200A Series, NPort 5400 Series, NPort 5600 Series, NPort 5600-DT Series, NPort 5600-DTL Series • Supports new functions of firmware 2.0.• Added new NPort IA model.• Added Web console toolbar.• Supports IOCTL_SERIAL_XOFF_COUNTER command (Windows 2000/XP/2003), which is used by some 16-bit programs.New Features• Registered COM number usage (Windows 2000/XP/2003). This will avoid other COM device from using the same COM number occupied by this driver.N/ASupported Operating SystemsNotesChangesApplicable ProductsBugs FixedN/AN/AEnhancementsN/AIndustrial Device Servers, NPort 5100 Series, NPort 5100A Series, NPort 5200 Series, NPort 5200A Series, NPort 5400 Series, NPort 5600 Series, NPort 5600-DT Series, NPort 5600-DTL Series • First release.New FeaturesN/AN/A。

5600中文说明书(润新)

5600中文说明书(润新)

5600 & 5600型ECONOMINDER®多路阀操作手册本手册包含FLECK5600时间型过滤器(5600FT),软水器(5600ST);流量型软水器(5600SM)的调试操作说明5600产品概述FLECK全自动控制器以闻名于世的FLECK公司软化水技术为基础,它是将软水器的运行及再生的每一个步骤实现全自动控制,并采用时间、流量或感应器等方式来启动再生。

由于FLECK系列全自动软水设备控制系统技术成熟、操作简便、富来控制器采用的工程塑料和无铅黄铜阀体完全符合食品卫生要求,配以聚四氟乙烯(Teflon)涂层,活塞减小了阻力,延长了使用寿命,运行可靠。

FLECK系列全自动软水器可用于家用、工业锅炉、热交换器、宾馆饭店、食品工业、洗衣印染、医疗卫生等行业,该产品具有自动化程度高、交换容量大、结构紧凑、能耗低、省人工、无需日常保养等特点。

系统技术参数进口压力:0.2 Mpa-0.6 Mpa工作温度:2 ℃—50℃进水硬度:符合国家标准出水硬度:≤0.03mmol/L使用电源:220v/50Hz AC布置形式:单罐或双罐串联(二级软化时采用)再生方式:顺流再生操作程序:自动程序控制使用树脂:001×7强酸性阳离子交换树脂我公司将为用户提供完善的技术服务及售后服务。

第1页5600ST安装和启动程序软水器的安装,应根据制造商建议的入水口、出水口和排污口接管,且应符合相关管路规范。

在软水装置接通电源前1.将软水器控制阀手动转至工作位置,打开进出水口,使水流入树脂罐。

直到管路内空气排尽,当水流流出出水口时,关闭进出水口。

注:可手动旋转控制阀前部的旋钮将其拨至不同的再生位置,直到显示软水器处于所需位置。

2.将控制阀手动转至反洗位置,使水经排水口流出3或4分钟。

3.取下控制阀后盖板。

4.确保盐的用量按制造商的建议设置。

如有必要,按设置说明书设置盐的用量。

将控制阀手动转至盐水重注位置,使水填充至空气止回阀顶。

5600水处理中文说明书

5600水处理中文说明书

5600 5600SE全自动软化水设备安装、运行及维护手册目录一、产品概述二、工作流程图三、设备的安装和运行四、设备安装示意图五、FLECK5600控制器的调试步骤六、FLECK56SE控制器的调试步骤七、FLECK56SE控制器全面编程及相关代号的意义列表八、故障排除产品概述首先感谢您使用本公司的全自动软化水设备!为着方便您的使用,我们编写了该产品的客户手册,您的认真阅读和理解一定能为产品的良好使用打下基础。

5600系列自动软水器分为时间周期型和流量周期型两种控制方式,用户可以根据当地水质及用户对于水质的要求来进行选择。

本产品广泛应用于蒸汽和热水锅炉、热交换设备、食品加工、造纸印刷、洗衣印染、家庭、宾馆饭店、医疗制药、纯水制备预处理等行业。

我公司将给用户提供完善的技术及售后服务。

自动软水器技术参数:入口水压:0.2Mpa-0.6Mpa工作温度:2-50℃电源型式:220V/50Hz AC电源功率:3W出口硬度:≤0.03mmol/L再生方式:动态顺流再生或逆流再生树脂型号:001×7强酸性阳离子交换树脂盐耗:<160-240g/mol(根据水质情况)FLECK5600/56SE控制器工作流程图说明:FLECK5600和56SE控制器的水流过程略为不同,但原理一致。

1、工作状态2、预清洗(5min)硬水经控制器进水口流过树脂层,软硬水经控制器进水口流过树脂层,软3、反洗(10min)4、吸盐(50min)5、慢洗6、快洗硬水经控制器进水口向下流过中心管、下布水器,向上流经树脂层,流出排水口,进行反洗。

硬水经控制器进水口,通过射流器,吸入盐液再生剂,向下流过树脂层进行再生还原,最后通过下布水器、中心管和排水口流出。

吸盐完成后,空气止回阀会将吸盐口封住,防止空气的进入,硬水继续经控制器进水口,通过射流器,向下流过树脂层,最后通过下布水器、中心管和排水口流出。

硬水经控制器进水口,向下通过中心管、下布水器,然后向上流过树脂层,最后通过排水口流出。

5600 5600 Econominder 用户手册说明书

5600   5600 Econominder 用户手册说明书

For questions or in case of emergency, please call your local service technician (preferably the one whoinstalled the system).IMPORTANT: The information, specifications and illustrations in this manual are based on the latest information available at the time of printing. The manufacturer reserves the right to make changes at any time without notice.Setting the Time of Day:To set the time of day, push the red button and spin the 24-hour gear until the present time of day is visible above the time of day arrow.Forcing a Manual Regeneration:To manually regenerate the valve, turn the manual regeneration knob clockwise until it reads“REGEN.”5600 ModelSetting the Time of Day:To set the time of day, push the red button and spin the 24-hour gear until the present time of day is visible above the time of day arrow.Setting the Program Wheel:To set the program wheel, lift the “people” dial and rotate it so that the number of people in the household is aligned with the household grains per gallon water hardness. Release the dial and check for firm alignment at the setting. This provides reserve capacity based on 75 gallons per person.Forcing a Manual Regeneration:To manually regenerate valve, turn the manual regeneration knob clockwise until it reads “REGEN.”NOTE: Unit will regenerate tonight when the gallon capacity reaches zero.5600 Econominder Model Setting Time of Day & Initiating a Manual RegenerationService:Hard water enters unit at valve inlet and flows down through the mineral in the mineral tank. Conditioned water enters center tube through the bottom distributor, then flows up through the center tube, around the piston, and out the outlet of the valve.Preliminary Rinse:Slow rinse of the resin bed. Water flows down through the resin bed up the bottom distributor and out the drain.Backwash:Hard water enters unit at valve inlet, flows through piston, down center tube, through bottom distributor, and up through the mineral, around the piston and out the drain line.Water is passed through the resin bed in the opposite direction of normal flow, which flushes suspended matter out of the resin tank. Backwashing also loosens the resin bed which becomes compacted during the softening (in service) cycle.Brine/Slow Rinse (Softener Only):Hard water enters unit at valve inlet, flows up into injector housing and down through nozzle and throat to draw brine from the brine tank, brine flows down through mineral and enters the center tube through bottom distributor and out through the drain line.The resin beads are washed with the strongsolution of salt water which is called the brinesolution. Since the resin beads prefer calciumand magnesium ions, the slow rinse allowsan overwhelming concentration of sodiumions to overpower and force the calcium andmagnesium ions off of the resin beads and arethen discharged down the drain.Rapid Rinse:The resin bed is rinsed to remove excess brinesolution from the tank and the resin beads arethen ready to produce soft water again.Hard water enters unit at valve inlet, flowsthrough piston, down center tube, throughbottom distributor, and up through the mineral,around the piston and out the drain line.Settling Rinse:Slow rinse of the resin bed. Water flows downthrough the resin bed up the bottom distributorand out the drain.Brine Tank Refill (Softener Only):Hard water enters unit at valve inlet, flows up through the injector housing, through the brine valve to refill the brine tank. Valve is now delivering soft water to the home. Raw water is refilling the brine tank to make a brine solution for the next regeneration.Regeneration:When the valve is in Regeneration, raw water is being passed to service until rapid rinse is complete.Descriptions of Softener & Filter Control Valve PositionsProblemSolution Control valve fails to regenerate Check for power outage and verify unit is plugged in.If this does not work, contact your local water servicetechnician (preferably the one who installed the system).Water does not feel or appear softCheck salt level in brine tank & maintain salt level abovewater level. If problem still exists, contact your localwater service technician.Unit uses too much saltContact your local water service technician.Loss of water pressureIron in conditioned waterExcessive water in brine tankOther problems with the watersoftenerPower Outage Reset the Time of Day in the event of a power outage/failure. See “Setting the Time of Day” page.Adding Salt Ensure that the salt level in the brine tank is always above the water line.Water Pressure Water pressure range of 20-125 psi is required for regeneration valve to operate effectively.Electrical FacilitiesAn uninterrupted alternating current (A/C) supply is required. Please make sure voltage supply is compatible with unit before installation.Existing PlumbingCondition of existing plumbing should be free from lime and iron buildup. Replace piping that has heavy lime and/or iron build-up. If piping is clogged with iron, install a separate iron filter unit ahead of the water softener.Location of Softener, Drain & Brine Tank Locate the softener close to a clean working drain and connect according to local plumbing codes. The brine tank should be located within 20 feet of the water softener. Drain cannot be elevated more than 36 inches or exceed 20 feet in length.Bypass Valves Always provide for the installation of a bypass valve if unit is not equipped with one. If valve is leak-ing, turn bypass from In Service to the Bypass Position.NOTE: If the valve continues to leak after turning the bypass to bypass position, shut off the main water line and call your local service technician (preferably the one who installed the system) IMMEDIATELY.General Residential Checklist & Troubleshooting5600 L-Style Econominder 5600 L-Style EconominderTo download the service manual for this valve, please visit:。

5600控制器使用说明书

5600控制器使用说明书

安装1、安装的一般要求①、进水压力应在0.2-0.5MPa,当水源压力无法满足要求时,可安装增压水泵提高进水压力。

如果压力过高,应安装减压阀来控制进水压力。

②、进水温度应在5-45℃之间,电源采用交流200V/50Hz。

③、软水器应安装在牢固的平台上,附近有畅通的下水,并留有足够的操作和维修空间。

④、工作环境温度应在5-50℃之间,相对湿度≤95%(5℃时)。

2、控制阀的安装与树脂填装(顶装形式)第一步:首先将下布水器牢固安装在中心管底端,然后插入到树脂罐中央,在中心管上端低于罐口0.5mm处截断并导角,然后用胶带封住中心管口,以防树脂漏入。

第二步:将石英砂沿中心管周围空隙投入树脂罐,并使之在罐底铺平,石英砂高于下布水器上20mm,石英砂应按粒径级别分层铺装,主要起到布水作用(对于直径小于500mm树脂罐一般不装石英砂)。

第三步:将树脂均匀地装入树脂罐中,装至规定的层高后,再向注入10%的食盐溶液,至浸没树脂为止,使树脂充分膨胀。

树脂装填完,应取下中心管的封口胶带,上述操作时应注意使中心管始终保持在树脂罐口的中央位置。

第四步:将上布水器安装到控制阀上,然后将中心管从上布水器内插入到控制阀内,小心地沿顺时针方向转动控制阀,直至旋紧在树脂罐接口上(或用法兰连接固定)。

注意上布水器与控制阀、中心管,下布水器与中心管必须严密,防止树脂跑出。

中心管与控制阀必须严密不漏水,否则会出现窜硬水现象。

3、管道连接要求①、与软水器连接的管道应采用给水塑料管,排水管不得采用软塑料管,防止管道变形,影响排水效果。

②、按照控制阀进出水箭头标记连接进出水管,采用流量型再生控制器,流量计必须安装在出水口。

③、进出水管应装有压力表及手动阀门,同时还应装有旁通阀,在出水管阀前还应安装有取样阀。

进水管阀后一般安装有 Y 型过滤器,防止管道内污物堵塞阀体造成设备无法正常运行。

④、排水管的连接长度不应超过6m,尽量减少弯度,并严禁安装阀门。

莫嘉(Moxa)NPort 5600系列快速安装指南说明书

莫嘉(Moxa)NPort 5600系列快速安装指南说明书

P/N: 1802056000216 *1802056000216*NPort 5600 Series Quick Installation GuideVersion 5.4, January 2021Technical Support Contact Information/support2021 Moxa Inc. All rights reserved.OverviewWelcome to the Moxa NPort 5600 Series. The NPort 5610-8/16 has 8 or 16 RS-232 ports, the NPort 5630-8/16 has 8 or 16 RS-422/485 ports, and the NPort 5650-8/16 has 8 or 16 RS-232/422/485 ports.NPort 5600 Series ModelsThe NPort 5600 Series includes the following models: NPort 5610-8, NPort 5610-16, NPort 5610-8-48V, NPort 5610-16-48V, NPort 5630-8, NPort 5630-16, NPort 5650-8, NPort 5650-8-T, NPort 5650-8-HV-T, NPort 5650-16-HV-T, NPort 5650-16, NPort 5650-16-T, NPort5650-8-M-SC, NPort 5650-16-M-SC, NPort 5650-8-S-SC, and NPort 5650-16-S-SC.Package ChecklistThe NPort 5600 package should contain the following items:• 1 NPort 5600 Series serial device server•Power cord (AC models only)• 1 DIN-rail/wall-mounting kit: WK-45-01•NPort 5600 Quick Installation GuideOptional Accessories:•CBL-RJ45M9-150: 8-pin RJ45 to DB9 male cable, 150 cm•CBL-RJ45F9-150: 8-pin RJ45 to DB9 female cable, 150 cm•CBL-RJ45M25-150: 8-pin RJ45 to DB25 male cable, 150 cm •CBL-RJ45F25-150: 8-pin RJ45 to DB25 female cable, 150 cm Note: Please notify your sales representative if any of the above items is missing or damaged.Hardware IntroductionNOTE The wide temperature model does not come with LCM display panels or push buttons. All of the LCM descriptions below applyonly to standard temperature models.The front and rear panels are shown below:Front panel of the NPort 5600 SeriesRear panel of the NPort 5610/5630/5650 (AC Power)Rear panel of the NPort 5650 (Fiber Model)Rear panel of the NPort 5610 (DC Power)Front panel of the NPort 5650-T SeriesReset Button—press the Reset button continuously for 5 seconds to load factory defaults: Use a pointed object to press the reset button. Release the button after the Ready LED stops blinking.LED Indicators on the Front Panel—the front panels of the NPort 5600 have several LED indicators, as described in the following table.Name Color FunctionReadyOff Power is off, or power error condition exists.RedSteady on: Power is on and the NPort is booting up.Blinking: Indicates an IP conflict, or DHCP orBOOTP server did not respond properly.GreenSteady on: Power is on and the NPort is functioningnormally.Blinking: The NPort has been located by NPortAdministrator’s Location function.1 to 16 Orange Serial port is receiving data.Green Serial port is transmitting data.OffNo data is being transmitted or received throughthe serial port.LCM Display Panel—If the NPort is working properly, the LCM panel will display a green color. The red Ready LED will also light up, indicating that the NPort is receiving power. After the red Ready LED turns green, you will see a display similar to:N P 5 6 1 0 - 1 6 3 81 92 . 1 6 8 . 1 2 7 . 2 5 4 This is where:•NP5610-16 is the NPort’s name•38 is the NPort’s local sequence number•192.168.127.254 is the NPort’s IP addressLCM Panel Operation—There are four buttons on the NPort 5600’s front panel. These buttons are used to operate the server’s LCM panel. Going from left to right, the buttons are:Button ActionMENU Activates the main menu, or returns to a lower level.︿Scrolls up through a list of items shown on the LCM panel’s second line.﹀Scrolls down through a list of items shown on the LCM panel’s second line.SEL Selects the option listed on the LCM panel’s second line. Detailed LCM Panel Operating instructions can be found in the NPort 5600 Series User’s Manual.Link Indicator on the rear panel of the NPort 5650 fiber model—the rear panels of the NPort 5650 have a link indicator, as described in the following table.LED Name LED Color LED FunctionLinkOff Fiber disconnected.Green Fiber connected, data not transmitting. Blinking Fiber connected, data is transmitting.Hardware InstallationSTEP 1: After removing the NPort 5600 from the box, the first thing you should do is attach the power adapter.STEP 2: Connecting the Power.AC: Connect the NPort 5600’s 100-240 VAC power cord to the AC connector. The “Ready” LED will show a solid red color until the system is ready, at which time it will change to a green color.DC: Connect the NPort 5600 VDC’s power cord to the DC connector, and then follow the steps given below:Take NPort 5610-8-48V as an example. Loosen thescrews on the V+ and V- terminals of the NPort5610-8-48V’s terminal block. Connect the powercord’s 48 VDC or -48 VDC wire to the terminal block’sV+ terminal, and the power cord’s DC Power Ground wire to the terminal block’s V- terminal, and then tighten the terminal block screws. (Note: The NPort 5610-8-48V can still operate even if the 48V/-48V and DC Power Ground are reversed.)The “Ready” LED will show a solid red color until the system is ready, at which time it will change to a green color.Grounding the NPort 5600 VDC:Grounding and wire routing help limit the effects ofnoise due to electromagnetic interference (EMI). Runthe ground connection from the ground screw to thegrounding surface prior to connecting devices. TheShielded Ground (sometimes called Protected Ground)contact is the second contact from the right of the5-pin power terminal block connector located on the rear panel of the NPort 5610-8-48V. Connect the SG wire to the Earth ground.STEP 3: Connect the NPort 5600 to a network. Use a standard straight-through Ethernet cable to connect to a hub or switch. When setting up or testing the NPort 5600, you might find it convenient to connect directly to your computer’s Ethernet port. In this case, use a cross-over Ethernet cable.STEP 4: Connect the NPort 5600’s serial port to a serial device. Placement Options: You can place the NPort 5600 on a desktop or other horizontal surface.Software Installation InformationFor the NPort’s configuration, the default IP address of the NPort is: LAN: Static; IP = 192.168.127.254; netmask = 255.255.255.0NOTE If you have forgotten the NPort's IP address, use the DeviceSearch Utility (DSU) from your PC to locate the NPort. After searching the LAN for NPort units, the DSU will display the IP address of each unit.You may log in with the password moxa to change any settings to meet your network topology (e.g., IP address) or serial device (e.g., serial parameters). For first-time use, click the Wizard in the left navigation panel. The wizard will prompt you to configure the IP address, SSID, and security mode. For other settings, use the factory defaults or modify the settings for your application.For software installation, download the relative utilities from Moxa's website:https:///support/support_home.aspx?isSearchShow=1 • Download the NPort Windows Driver Manager and install it as the driver to run with Real COM mode of the NPort Series.• Execute NPort Windows Driver Manager; then map the virtual COM ports on your Windows platform.• You may refer to the pin assignment section to loop back pin 4 and pin 5 for the RS-232 interface to carry out a self test on the device.•Use HyperTerminal or a similar program (you may download Moxa's program, called PComm Lite) to test whether the device is good or not.Pin Assignments and Cable WiringSerial Port Pinouts for the NPort 5610Serial Port Pinouts for theNPort 5630PinRS-232 1 DSR (in) 2 RTS(out) 3 GND 4 TxD(out) 5 RxD(in) 6 DCD(in) 7 CTS(in) 8 DTR(out)Pin RS-422/ RS-485-4WRS-485-2W1 – –2 – –3 TxD+ –4 TxD- –5 RxD- Data-6 RxD+ Data+7 GND GND 8––Serial Port Pinouts for the NPort 5650Pin RS-232 RS-422/RS-485-4WRS-485-2W 1 DSR – – 2 RTS TxD+ – 3 GND GND GND 4 TxD TxD- – 5 RxD RxD+ Data+ 6 DCD RxD- Data- 7 CTS – – 8 DTR – –Serial Cables for the NPort 5630 (2-wire RS-485)Serial Cables for the NPort 5630 (RS-422/4-wire RS-485)Serial Cables for the NPort 5610/5650 (RS-232)Serial Cables for the NPort 5650 (RS-422/4-wire RS-485)Serial Cables for the NPort 5650(2-wire RS-485)。

德尔格 X-am 5600 使用说明书

德尔格 X-am 5600 使用说明书

使用说明书21)技术手册,传感器技术数据/使用说明书,以及德尔格 X-am5600的电脑软件 CC vision 都包含在 CD 内。

请查阅使用说明书附件中的传感器的技术数据。

为了您的安全请严格遵守使用说明使用本仪器要求完全理解并严格遵守使用说明。

本仪器只能用于说明书中严格规定的用途。

维修保养必须严格遵守本技术手册 1),使用说明,以及德尔格传感器技术数据中所说明的维修保养时间和措施。

仪器只能由经过训练的维修人员进行维修。

配件只能使用技术手册的订货列表中规定的配件。

与电气设备的安全连接使用说明书中未提及的设备需在咨询制造商或专家后与电气设备连接。

在爆炸危险区域的应用根据本国、欧洲或国际防爆规定进行过测试和批准的用于爆炸区域的仪器或配件仅能按照标准中明确规定的条件使用,并应遵守相关的法律规定。

不得对设备或配件进行任何修改。

禁止使用故障或不完整的配件。

在对仪器或配件进行维修时,需始终遵守相应规定。

仪器只能由经过训练的维修人员根据德尔格的维修说明进行维修。

使用说明书中的安全标识使用说明书中使用了一系列可能产生危险的警告标识。

这些警告标识包含一些提醒您可能遇到危险的信号词汇。

这些信号词汇和相应危险如下:设计用途便携式气体检测仪器可用于对工作区域和爆炸性危险区域的环境空气中所含有的几种气体浓度进行连续检测。

根据安装的德尔格传感器不同,仪器可独立检测最多6种气体。

表示如何使用仪器的附加说明。

注意检测和认证见相关的“认证信息”,“标志”。

可以在提供的 CD中找到认证证书。

设计的操作区域及操作条件按区域划分的爆炸性危险区域该仪器设计用于爆炸性危险的区域或矿井,在这些被划分为0区,1区或2区的区域中,可能存在甲烷,操作温度范围为-20°C-+40°C或+50°C。

仪器也用于有IIA,IIB或 IIC类爆炸气体和温度等级为 T3或 T4(取决于应用的电池组和可充电电池)的区域。

如果应用于矿井,仪器只能用于机械碰撞风险较低的区域。

X-am 5600操作使用说明

X-am 5600操作使用说明

X-am 5000/5600操作使用一、开机1. 按住 “OK”-键 3 秒钟2. 屏幕倒数 3-2-13. LED 灯闪烁, 声音和振动报警启动自动检测并显示以下内容: A. 已安装软件版本 B. 各种报警级别设置C. TWA 和STEL 报警设置D. 下次标定日期 二、关机1. 同时按住“+” 和 “OK ” 键超过三秒2. LED 灯闪烁并鸣音3. 仪器关机 三、照明显示1. 按下任何键屏幕照明都会打开30秒.2. 报警时屏幕照明会自动打开四、新鲜空气标定1. 此过程为新鲜空气标定,可利用CC Vision 软件或者快捷菜单进行.2. 按下 “+”键三次3. 显示以下图标4. 按下 “OK ”-键并选择新鲜空气标定菜单5. 显示真实浓度值6. 按下 “OK ”- 键7. 屏幕上显示OK8. 完成新鲜空气标定如果新鲜空气环境下氧气传感器浓度值不为20.9% 或者不稳定, 或者可燃气体或有毒气体传感器不显示 “0”,则必须进行新鲜空气标定. 必须在洁净的环境下进行新鲜空气标定.,五、最大值菜单1. 按住 “OK ”-键3秒钟XXS 传感器槽XXS 传感器槽 视觉报警光报警 催化燃烧传感器分段显示 > 90 db+M – 导航键on – 开机及确认键2. 显示氧气传感器的最大值. 数值从仪器上次重设起开始记录3. 再按“OK”键.4. 屏幕上显示TWA 和STEL 值5. 或者按一下“+”键6. 仪器返回测量模式A.最大值功能显示重设仪器读数后氧气最低浓度值和其它气体最高浓度值。

B.用户可以使用快捷菜单查看最大值也可利用CC vision软件设置最大值数值。

TWA为时间加权平均浓度值,指几乎所有的工人在正常的8小时工作日和40小时工作周内可整日反复地暴露在这样的物质浓度环境下而对健康没有不良的影响.为短时间暴露浓度允许值,指工人在15分钟内可以连续地暴露在这样的环境内而不会遭受;过敏慢性或不可恢复的肌肉损伤足够程度的麻醉而增加以外事故的可能性,不能够自我抢救或者降低工作效率.六、TWA1.当TWA分析功能激活后:2.按住“OK”-键3秒钟3.按下“OK ”-键一次4.屏幕上显示图标5.显示最大工作浓度6.再次按下“OK”-键显示STEL 值.7.或者再按一下“+”键8.仪器返回测量状态七、STEL1.当STEL分析功能激活后2.按住“OK”键三秒钟3.按下“OK ”键两次4.屏幕上显示图标5.显示STEL 值6.按下“OK ”-键或者“+”键一次7.仪器返回测量八、A1 气体浓度报警1.报警级别可以通过CC-Vision软件设置和更改2.单频声音、光和振动报警周期重复出现3.屏幕交替显示“A1” 和气体浓度4.A1报警(除了O2), 可以通过按下“OK ”键确认声音和振动报警.九、A2气体浓度报警1.报警级别可以通过CC-Vision软件设置和更改2.双频声音、光和振动报警周期重复出现3.屏幕交替显示“A1” 和气体浓度4.“A2”或者O2 “A1”声音,光和振动报警都不能被确认(静音)十、STEL 报警1.报警级别可以通过CC-Vision软件设置和更改2.声、光和振动报警周期重复出现,3.屏幕交替显示“A2”和气体浓度4.闪烁图标5.报警无法被确认重设仪器后会取消TWA和STEL值.遵从所述安全操作流程.十一、TWA 报警1.报警级别可以通过CC-Vision软件设置和更改2.声、光和振动报警周期重复出现3.屏幕交替显示“A2”和气体浓度4.闪烁图标5.报警无法被确认重设仪器后会取消TWA和STEL值.遵从所述安全操作流程.A1 低电量报警1.声、光和振动报警周期重复出现2.闪烁图标3.这些报警可以通过选择“OK”静音电池还有不到10分钟操作时间时自动激活此功能请更欢电池或者对仪器进行充电.十三、A2 低电量报警1.声、光和振动报警周期重复出现2.闪烁图标3.仪器倒数10秒后自动关机4.仪器关机5.报警无法确认十四、故障报警1.声、光和振动报警周期重复出现2.屏幕上显示图标3.这些报警可以通过选择“OK”静音,但是屏幕上仍然显示故障图标一旦屏幕上有故障显示需要立即对仪器进行检查。

安讯士5600系列机械热探测器技术规格说明书

安讯士5600系列机械热探测器技术规格说明书

5600 SeriesMechanical Heat DetectorsDN-6931:A1 • I-304GENERALSystem Sensor’s 5600 Series mechanical heat detectors offerproperty protection against fire and for non-life-safety installa-tions, where smoke detectors are inappropriate.Multiple configurations. The 5600 Series offers a full line ofconfigurations to accommodate a broad range of applications.Bo th single- and dual-circuit mo dels are o ffered, each avail-able fo r lo w- and high-temperature ratings with either fixed-temperature o r c o mbinati o n fixed-temperature/rate-o f-rise(ROR) activation. The ROR element of the fixed/ROR modelsis restorable, to accommodate field-testing the unit.Installation flexibility. To satisfy a variety of installations, the5600 Series easily mounts to single-gang and octagonal back-bo xes. These mo dels also acco mmo date 4" (101.6 mm)square backboxes when used with a plaster ring. The mount-ing bracket is reversible to allow for flush- and surface-mount backbox installations.Visual identification. The 5600 Series provides clear mark-ings on the exterior of the unit to ensure that the proper detec-to r is being used. Alphanumeric characters identify the activatio n metho d, as well as the temperature rating, in degrees Fahrenheit and Celsius. Fixed temperature mo dels are identified “FX”, while co mbinatio n fixed/rate-o f-rise units are marked “FX/ROR”. The 5600 Series also provides a col-lecto r as a po st-activatio n indicato r. Once the detecto r has been activated, the collector drops from the unit to allow easy identification of the specific unit in alarm.FEATURES•Multiple configurations available:–Fixed-temperature (no n-resettable) o r co mbinatio n fixed (non-resettable)/rate-of-rise (self-restoring).–Low-temperature and high-temperature ratings.–Single-circuit and dual-circuit.•Easy-to-read alphanumeric identificatio n o f detecto r type and temperature rating.•External collector provides visual indication of activation.•Reversible mo unting bracket fo r flush- and surface-mo unt installations.•Flexible mounting capabilities: single-gang, 3.5" or 4" octag-onal, 4" (101.6 mm) square with plaster ring.•Easy-to-use terminal screws provide a more positive wiring connection.•Low-profile design to coordinate with room aesthetics.AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status.•UL Listed: S2101•ULC Listed: S2101 (all with “A” suffix)•MEA: 199-03-E•CSFM: 7270-1209:227, 7270-1653:167•FM Approved SPECIFICATIONSPHYSICAL SPECIFICATIONSMaximum installation temperature:For models 5601P, 5603, 5621, 5623: 100°F (38°C).For models 5602, 5604, 5622, 5624: 150°F (65.6°C).Alarm temperature:For models 5601P, 5603, 5621, 5623: 135°F (57°C).For models 5602, 5604, 5622, 5624: 194°F (90°C).Rate of Rise Threshold: 15°F (8.3°C) per minute (mo dels 5601, 5602, 5621, 5622 only).Operating Humidity Range: 5% to 95% RH noncondensing. Input Terminals: non-polarized, accept 14 to 22 AWG (2.0 to 0.33 mm²).Dimensions: diameter with mounting bracket: 4.57" (116 mm); height with mounting bracket: 1.69" (43 mm).Weight: 6 oz. (170 grams).Mounting Options: 3.5" (88.9 mm) o ctago nal backbo x; 4" (101.6 mm) o ctago nal backbo x; single-gang backbo x; 4" (101.6 mm) square backbo x with a square-to-ro und plaster ring.ELECTRICAL SPECIFICATIONSMechanical heat detecto r shall be a System Senso r 5600 Series model number ______, Listed to Underwriters Labora-tories UL 521 for Heat Detectors for Fire Protective Signaling Systems. The detector shall be either a single-circuit or a dual-circuit type, normally open. The detector shall be rated for acti-vation at either 135°F (57°C) or 194°F (90°C), and shall acti-vate by means o f a fixed-temperature thermal senso r, o r a c mbinati n fixed-temperature/rate-f-rise thermal sens r. The rate-o f-rise element shall be activated by a rapid rise in temperature, appro ximately 15°F (8.3°C) per minute. The detector shall include a reversible mounting bracket for mount-Operating Voltage Contact Ratings (resistive)6 - 125 VAC 3.0 A6 - 28 VDC 1.0 A125 VDC0.3 A250 VDC0.1 A6931pho1.jpgDN-6931:A1 • 2/9/10 — Page 1 of 2Page 2 of 2 — DN-6931:A1 • 2/9/10©2010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited.This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements.All specifications are subject to change without notice.For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118.ing to 3.5-inch (88.9 mm) octagonal, 4-inch (101.6 mm) octag-o nal, single gang, and 4-inch (101.6 mm) square backboxes with a square-to -ro und plaster ring. Wiring co nnectio ns shall be made by means of SEMS screws that shall accommodate 14 – 22 AWG wire. The detecto r shall co ntain alphanumeric markings on the exterior of the housing to identify its tempera-ture rating and activation method. The rate-of-rise element of co mbinatio n fixed-temperature/rate-o f-rise mo dels shall be restorable, to allow for field-testing. The detectors shall include an external collector that shall drop upon activation to identify the unit in alarm.ORDERING INFORMATIONWIRING DIAGRAMSModel*IdentificationMethod on ExteriorCircuit TemperatureRatingActivationUL Protected Spacing,10’ (3.048 m) Ceiling*5601P None Single 135°F (57°C)Fixed-Temperature/Rate-of-Rise 50 ft. x 50 ft. (15.24 m x 15.24 m)5602Lettering Single 194°F (90°C)Fixed-Temperature/Rate-of-Rise 50 ft. x 50 ft. (15.24 m x 15.24 m)5603Lettering Single 135°F (57°C)Fixed-Temperature 25 ft. x 25 ft. (7.62 m x 7.62 m)5604Lettering Single 194°F (90°C)Fixed-Temperature 25 ft. x 25 ft. (7.62 m x 7.62 m)5621Lettering Dual 135°F (57°C)Fixed-Temperature/Rate-of-Rise 50 ft. x 50 ft. (15.24 m x 15.24 m)5622Lettering Dual 194°F (90°C)Fixed-Temperature/Rate-of-Rise 50 ft. x 50 ft. (15.24 m x 15.24 m)5623Lettering Dual 135°F (57°C)Fixed-Temperature 25 ft. x 25 ft. (7.62 m x 7.62 m)5624Lettering Dual 194°F (90°C)Fixed-Temperature 25 ft. x 25 ft. (7.62 m x 7.62 m)NOTE: Refer to NFPA 72 guidelines for spacing reductions when ceiling heights exceed 10 feet (3.048 m).* Add an “A” to part number for ULC model .Single-Circuit ModelsDual-Circuit Models6931wir1.wmf6931wir2.wmf。

5600水处理中文说明书

5600水处理中文说明书

5600 5600SE全自动软化水设备安装、运行及维护手册目录一、产品概述二、工作流程图三、设备的安装和运行四、设备安装示意图五、FLECK5600控制器的调试步骤六、FLECK56SE控制器的调试步骤七、FLECK56SE控制器全面编程及相关代号的意义列表八、故障排除产品概述首先感谢您使用本公司的全自动软化水设备!为着方便您的使用,我们编写了该产品的客户手册,您的认真阅读和理解一定能为产品的良好使用打下基础。

5600系列自动软水器分为时间周期型和流量周期型两种控制方式,用户可以根据当地水质及用户对于水质的要求来进行选择。

本产品广泛应用于蒸汽和热水锅炉、热交换设备、食品加工、造纸印刷、洗衣印染、家庭、宾馆饭店、医疗制药、纯水制备预处理等行业。

我公司将给用户提供完善的技术及售后服务。

自动软水器技术参数:入口水压:0.2Mpa-0.6Mpa 工作温度:2-50℃ 电源型式:220V/50Hz AC 电源功率:3W出口硬度:≤0.03mmol/L再生方式:动态顺流再生或逆流再生 树脂型号:001×7强酸性阳离子交换树脂 盐 耗:<160-240g/mol (根据水质情况)FLECK5600/56SE 控制器工作流程图说明:FLECK5600和56SE 控制器的水流过程略为不同,但原理一致。

1、 工作状态2、预清洗(5min )硬水经控制器进水口流过树脂层,软化后经下布水器、中心管向上流出出水口,此时设备处于工作状态。

硬水经控制器进水口流过树脂层,软化后经下布水器、中心管向上流出排水口,进行预清洗。

3、反洗(10min)4、吸盐(50min)5、慢洗6、快洗硬水经控制器进水口向下流过中心管、下布水器,向上流经树脂层,流出排水口,进行反洗。

硬水经控制器进水口,通过射流器,吸入盐液再生剂,向下流过树脂层进行再生还原,最后通过下布水器、中心管和排水口流出。

吸盐完成后,空气止回阀会将吸盐口封住,防止空气的进入,硬水继续经控制器进水口,通过射流器,向下流过树脂层,最后通过下布水器、中心管和排水口流出。

日立5600 5601手携式转速计使用说明书

日立5600 5601手携式转速计使用说明书

MODEL5600/5601 使用说明书1. 产品种类品名 型号内容MODEL 5600MODEL 5600本体 单4电池4节, 反射胶带10个 手携式转速计MODEL 5601(8点存储,显示单位切换)MODEL 5600本体 单4电池4节, 反射胶带10个接触测定用适配器MODEL 8089(5600和5601均可使用)适配器本体橡胶接触头3个 周速轮(外周1/10m )延长光电探棒MODEL 8090(5600和5601均可使用)延长光电探棒 (φ21 导线最长1m )2. 各部件名称橡胶接触头 延长光电探棒单位显示 反射光检测显示延长光电探棒用接口内部电池盒的滑动开关切换后可使用延长探棒测试线3. 使用前准备3.1 电池安装1.用手指按住转速计背面电池盖的部分向下移动,打开电池盖。

2.仪器电池盒内部的滑动开关可设置ON(仅仪器本体、本体+适配器使用时)或OFF(延长光电探棒使用时)。

3.将电池(单4)4节按正确位置放入。

4.将电池盖盖上并安装。

3.2 反射胶带的安装——使用非接触式时将标配的反射胶带剪下1~3米长度,撕下胶带背面的牛皮纸,将其贴在被测旋转体上。

z请先擦拭贴胶带处的油污和脏物。

z请尽量将胶带贴在最靠近旋转体外周的地方。

3.3 接触式适配器的安装——使用接触式时将转速计背面的锁定螺丝拧松,接触测定用适配器从仪器上方插入后使用螺丝刀将螺丝固定。

没有螺丝刀时可借助硬币拧紧。

请确保适配器在使用中不会松动。

3.4 延长光电探棒的安装仪器电池盒中的滑动开关设置为OFF后将延长光电探棒的接头插入仪器左侧的标准接口。

4.测量4.1 使用非接触式测量时(1.)使仪器本体或延长光电探棒与所贴胶带保持5~30cm的距离,光的投射角度设定在±30°以内。

(2.)按测试开关,确认显示屏出现“”标志后读取测试值。

(3.)松开测试开关后,测试值将保留3分钟,然后切断电源。

* MODEL 5601在按键操作完成后3分钟自动切断电源。

5600(V5.0)高精密数字温度计使用说明书

5600(V5.0)高精密数字温度计使用说明书

2. 技术指标
(1) 测量范围和允许误差:
tyPE 代码 0 1 2 3 4 10 11 12 13 分度号
[ ]
有效测量范围 (-100.000~+200.000)℃ (-200.000~+850.000)℃ (-140.000~+320.000)℃ (-50.000~+150.000)℃ (-50.000~+150.000)℃ (0.000~2220.00) Ω (-100.000~+200.000)mV (-2.000~+24.000)mA (-200.00~+1372.00)℃
F2: mV or mA 接线图
F3: TC (INT)接线图
F4: TC (EXT)接线图
(1) 热电阻和电阻档的接线:采用 4 线制形式,见上图的 F1,插头左边的两条线接热电 阻或电阻的一端,插头右边的两条线接热电阻或电阻的另一端。 特别注意:这里的 4 线制插头不作为 USB 接口用途,不要用此插头去和电脑或其他 设备的 USB 接口连接,以免造成损坏! (2) 直流 mV 信号的接线:应采用纯铜质的导线、插头、连接片进行连接,见上图的 F2。为 减少热电势影响,应及时清除其表层污物。几种材料和铜的热电势见下表,供参考。 铜-铜 铜-铜氧化物 铜-锡 0.2μV/℃ 1000μV/℃ (1~3)μV/℃ 铜-银 铜-金 铜-铁 0.3μV/℃ 0.3μV/℃ 10μV/℃
4-wire connector
Copper connector
Thermocouple meterial connector
4-wire connector Copper conector
Y UD IAN

松下VTR5500、VTR5600說明書说明书

松下VTR5500、VTR5600說明書说明书
在播放目錄清單中選擇“複讀模式”目錄,再按目錄鍵將進 入複讀模式。A-B 複讀的具體操作請參考“音樂播放”部分的 A-B 複讀操作部分。
刪除檔案 在停止播放錄音檔案介面下,按住刪除鍵約 2 秒,將會顯示 如下第一張圖所示介面。下面為執行刪除操作的相關參考圖片:
12 個性化設置 你可根據個人喜好進行以下相應設定。 在語音播放停止介面下,短按目錄鍵,將會彈出功能目錄清 單,功能包括:錄音類型、數位降噪、聲控設置、監聽設置、系 統時間、定時錄音、分段錄音。相關參考圖片如下圖所示:
3 4 開始使用
開/ 關機 注意:第一次使用機器時,請對該機器充電三小時以確保機 器有電工作! (1): 當電源開關處於“關”位置時,則本機斷開電源,不能開機。 (2): 當電源開關由“關”撥到“開”位置後,本機立即自動開
機,然後顯示“PHILIPS”,如下圖所示。
然後機器進入錄音檔案停止播放介面,如下圖所示,在此介面 長按 MENU 鍵約 2 到 3 秒鐘,機器返回主介面。
Voice Tracer
(VTR5500/VTR5600 錄音筆)
使用手冊
本產品台灣區售後服務由 旺德電通股份有限公司 負責 產品註冊請至 HTTP://WONDER.TW 3 您的數位錄音筆 附件清單:
概覽:
目錄 1 歡迎
2 重要須知
注意:設定定時錄音時,在關機狀態一定要保證機器電源開 關在 ON 狀態,否則定時錄音時間到時,無法執行定時錄音。 (7): 分段錄音
在錄音過程中,分段錄音功能可在每 30 或 60 分鐘自動將 錄音檔案分段保存並自動進入下一個檔案錄音。分段錄音功能參 考介面如下圖所示:
21 過以下方式退出複讀模式。 • 取消複讀:短按“播放”鍵,將之前設置 AB 複讀取消,並 暫停播放。短按“停止”鍵,將之前設置 AB 複讀取消,並 停止播放。短按“目錄”鍵,將之前設置 AB 複讀取消,並 返回正常播放狀態。

惠普惠能IPC 5000 5600用户手册说明书

惠普惠能IPC 5000 5600用户手册说明书

and designed using the latest technology. They offer a modular solution with all of the well known features of an industrial PC.The IPC 5000 and IPC 5600 are modular industrial PCs consisting of the following components: m Bus Unitm System Unitm Interface Boardm Mass Memorym Processorm System MemoryMeasurementsFor the most part, measurements are given as metric values in this manual. There are metric to imperial conversion tables provided on the last page of this publication.Bus UnitThe bus unit makes up the upper housing and contains the system bus and power supply. Bus units are available with a 24 VDC or 100 - 240 VAC power supply.System UnitThe system unit makes up the lower housing and contains the motherboard and system interfaces.Interface BoardThe optional interface board provides 2 extra COM ports, a CAN interface and a PC Card slot. It can be ordered with or without Ethernet connection.ProcessorPentium® processors with clock frequencies from 100 - 200 MHz and also AMD K6/266 processors are available.System MemoryDRAM ranging from 8 - 128 MB can be installed on the IPC 5000/5600.2) For hard disk: 150 G, 2 msec3) For hard disk: 0.5 G, 5 – 500 HzInstallation dimensions for IPC 5000 Controller with 2 or 4 slots:2.2 INSTALLATION DIMENSIONS - IPC 5600Installation dimensions for IPC 5600 Controller with 4 or 6 slots are shown on the followinig page.2.3 INSTALLATION GUIDELINESm IPC 5000 and IPC 5600 controllers can be installed on the back of the display unit (standard installation).m The screws delivered with the controller must be used for the installation.m The IPC 5000 controller must be installed in the upright position (connectors facing down).m The IPC 5600 controller must be installed horizontally (connectors facing right as seenThe following components are available on the IPC 5000:。

MODEL 5600 说明书

MODEL 5600 说明书

1.手动调整软水器控制器进入运行位臵,让水流入树脂罐。

当水流停止时,打开一已软化水的旋塞直到所有空气从管线中释放出来,然后关闭旋塞。

注:各种再生位臵通过转动控制器前的旋钮可以手动拨动,直到指示器显示软水器在需要的位臵。

2.手动调整控制器到反洗位臵,允许水流在3至4分钟内排干。

3.移动后盖板。

4.确保盐的用量与厂商建议的一样。

如果必要,设臵盐用量与设臵说明书中的一致。

手动调整控制器到盐水注满位臵,允许盐箱注满到空气阀的顶部。

5.手动调整控制器到吸盐位臵,允许控制器从盐箱吸盐直到它停止。

6.插上电源,看马达背后的观察孔,观察到它正在运行。

通过滑动跳跃轮外表的突针以暴露开关指针来设臵再生将要发生的时间。

每一个突针是一天。

在红色指示器的指针是今晚。

从红色指示器顺时针移动,延伸或缩进指针以获得需要的再生时间表。

7.手动提升控制器至盐水注满位臵的开始处;允许控制器自动回到运行位臵。

8.注满盐箱的盐。

9.将后盖还原到控制器上。

10确认在普通运行位臵任何旁通阀在左侧。

软水器流程图运行阀门驱动组件盐箱盐水位空气阀阀门组件位臵盐阀盐位树脂高度树脂罐布水器流量控制射流器初步反洗吸盐慢洗快洗沉淀物排水清洗位臵位臵位臵位臵位臵清洗位臵流量控制进水盐箱注5分钟 10分钟 50分钟固定周期的第一个位臵 50分钟固定周期的最后位臵出水水位臵10分钟 5分钟 4-24分钟可调周期硬水在阀进口处进入设备—在较低的活塞凹槽四周流动—流过通道至罐顶部—向下通过树脂并进入布水器,已为处理水。

处理水向上流经中心管至阀出口。

硬水在阀进口处进入设备—在较低的活塞凹槽及较低活塞环区四周流动—向下通过中心管,由布水器出来—向上通过树脂—通过罐通道顶部—绕过上部活塞凹槽并流出排水管。

在从盐箱中将所有盐水吸出后,硬水继续从阀进口处进入—在较低的活塞凹槽四周流动—通过喷嘴和孔口—向下通过树脂,流入布水器—向上通过中心管—通过活塞中的中心孔,流出排水管。

TL-WDR5600无线路由器说明书下载.pdf

TL-WDR5600无线路由器说明书下载.pdf
再次输入,点击 。以后登录路由器管理页面请使用已设置的管理员密码。 提示:
若忘记了登录密码请点击登录页面上的忘记密码并根据提示将路由器恢复出厂设置。一旦将路由器恢复出厂设置,您 需要重新对路由器进行配置才能上网。
3. 选择适合您的上网环境的上网方式并填写网络运营商提供的参数。 •• 宽带拨号上网
如果上网方式为宽带拨号上网,即ADSL虚拟拨号方式,网络运营商会提供上网帐号和口令,在下图所‎ 示页面 中填写该内容。点击 进行无线参数的设置。
第3章 管理设备上网行为 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 3.1 管理已连接设备 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 3.2 家长控制 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
1.2.1 基本上网参数配置 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 1.2.2 高级上网参数配置 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

HC5600 模拟集成电路测试系统 操作手册说明书

HC5600 模拟集成电路测试系统 操作手册说明书

HC5600模拟集成电路测试系统操作手册BY_JC_HC20220520深圳市华测半导体设备有限公司前言致尊敬的用户:非常感谢您使用HC5600模拟集成电路测试系统,为了使您更好地使用本测试系统,在您还没有使用本测试系统之前,请您在安装前仔细阅读本测试系统的使用手册,以确保测试系统正常运行。

软件说明书第一章:系统软件说明一简介HC5600模拟集成电路测试系统控制软件是在WindowsXP/WIN7环境下,利用Visual C++6.0作为系统开发工具开发的集成测试管理系统。

测试系统软件包括:测试处理、测试数据显示、数据统计、测试程序管理、测试程序框架自动生成、多种功能集成在一起。

提供操作方便的用户界面,使用者通过菜单、工具条,快捷键等操作程序。

不需要对C++的编写方法有很深的了解,系统自动生成测试程序框架,并提供专用的测试函数。

测试程序开发人员只需编写测试过程,显示、统计等功能系统自动处理,不需要用户再次开发,提高测试程序的开发效率。

二软件安装1.文件构成说明User――――――――存放用户测试程序的默认目录Include――――――――存放.h头文件目录Library――――――――存放.lib文件目录Califile――――――――存放校准数据,自检结果目录HC5600.exe――――――――测试管理系统执行主程序ComplieDlg.exe――――――――图形编译与查错程序comm3196a.dll――――――――测试程序专用函数库datalog.dll――――――――测试数据接口库*.dat――――――――系统数据文件*.Sum――――――――保存统计数据文件*.dlg――――――――保存测试数据文件(Txt)*.prg――――――――测试程序设置文件*.prgtmp――――――――测试程序设置文件备份,用于在乒乓测试环境,自动产生。

*.csv――――――――保存测试数据文件(Excel)2.安装软件将U盘中JC3196DXII目录拷贝到D:\下,目录名必需为JC3196DXII。

飞利浦 VTR5600 数码录音笔 使用手册说明书

飞利浦 VTR5600 数码录音笔 使用手册说明书

目录1欢迎2重要须知3您的数码录音笔4开始使用5录音6语音模式7音乐模式8调频模式9系统设置10常见问题11技术参数1欢迎欢迎来到飞利浦世界!您能选择和购买飞利浦的产品,我们非常高兴。

您可在我们的官方网站上获得飞利浦公司的全方位技术支持,如:使用手册、软件下载、保修信息等。

产品特点•一键录音:仅仅拨上录音开关即可实现录音,拨下保存录音。

•数字降噪:能有效地对录音环境周围的噪声给予滤除,从而可以清晰地记录有效的声音。

(此功能只建议在嘈杂的环境中使用,且录音格式为WAV比特率为384kbps)•以常见的MP3格式录音。

•使用高速USB2.0快速存取录音文件和数据。

•声控录音功能。

•可作为大容量的USB存储设备,确保最大的兼容性。

2重要须知安全•为了避免短路,切勿将产品放置在触水受潮处。

•不要将产品放在加热设备附近或阳光直射的地方。

•请注意,切勿挤压电缆,特别是插头处。

特别声明:使用本产品前请仔细阅读本说明书,如因人为操作或不可抗因素而导致数据丢失,本公司一概不予负责。

特别提醒用户小心操作,注意将资料另外备份。

听力保护使用耳机时请遵守下列原则:•调整至合适的音量,切勿长时间使用耳机。

•特别需要注意,切勿将音量调至耳朵所能承受的范围之外。

•切勿将音量调至盖过周边环境的声音。

•在危险情况下请小心或暂停使用耳机。

•在驾驶汽车、骑自行车、玩滑板时,切勿使用耳机。

否则会导致交通意外,且违反法律法规。

3你的数码录音笔Voice Tracer 供货范围:概览:1.内置麦克风2.麦克风插孔,Line in插孔3.耳机插孔4.电源开/关5.锁定开关HOLD6.菜单键MENU7.显示屏8.录音/播放指示灯9.播放/暂停键10.停止键,文件夹切换键11.录音键12.音量键VOL13.音量加,上一曲,快退,菜单项选择键14.音量减,下一曲,快进,菜单项选择键15.删除键16.扬声器B接口4开始使用开/关机注意:第一次使用机器时,请对该机器充电三小时以确保机器有电工作!(1)当电源开关处于“关”位置时,则本机断开电源,不能开机。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
五、通电设置 仪表接通电源后进入自检(自检状态见右图),自检完毕后,仪表自 动转入工作状态,在工作状态下,按压 键显示LOC,LOC参数设 置如下: 1、1) Loc等于任意参数可进入一级菜单(LOC=00;132时无禁锁) 2) Loc=132,按压 键4秒可进入二级菜单; 3) Loc=128,按压 键4秒可进入三级菜单,进行流量系数自 动演算; 4) Loc=130,按压 键4秒可进入时间设置菜单; 5) Loc=111,允许累积流量值手动清零; 6) Loc等于其它值,按压 键4秒退出到测量画面。 2、如果Loc=577,在Loc菜单下,同时按住 键和 键达4秒,可 以将仪表的所有参数恢复到出厂默认设置。 3、在其它任何菜单下,按压 键4秒可退出到测量画面。 ★ 返回工作状态 1.手动返回:在仪表参数设定模式下,按压 键4秒后,仪表 即自动回到实时测量状态。 2.自动返回:在仪表参数设定模式下,不按任何按键,30秒后, 仪表将自动回到实时测量状态。
-5-
(1)本仪表上下限报警控制输出带回差,以防止输出继电器在报警临界点上下波动时 频繁动作。
工作如下:
★测量值由低上升时: ★测量值由高下降时:
下限回差值
上限回差值
下限报警输出 ON ON OFF
上限报警输出 OFF ON ON
返回到初 始画面LOC
★ 流量补偿系数Kx的说明
设定二级参数KE=1时,可由一级参数Kx实现流量输入的非线性补偿,系数K的补偿曲
线示意图如下:
流量补偿系数
补偿曲线 K4
K3
K2
K1
流量(差压、
频率输入值)
F-L
1/3
2/3
F-H
设定系数Kx可补偿流量非线性输入的信号。 此功能也可用来实现频率输入的小信号切除功能。 流量(线性、差压或频率)输入值小于CAL时,由K1作系数补偿;流量(线性、差压或频率)输入值大于CAH 时,由K4作系数补偿。 线性补偿时一般设定二级参数KE=0,则在一级参数设定时只有参数K1作补偿系数,K2、K3、K4不予显示。 注:当频率输入时此功能无效。如频率输入设此参数仪表程序出错。 ★ 控制输出方式(AL1、AL2、AH1、AH2) 控制功能可由二级参数中"ALM"值来选择,详见后文。
New Hong Run Precision Instruments Co., LtD.
-1-
可设定流量小信号切除功能(瞬时流量值小于设定值时显示为0) 可设定流量定量控制功能 可自动进行温度、压力补偿 可编程选择以下几种传感器形式: 1、ΔP 输入为差压式流量传感器 2、ΔP 、T 输入为差压式流量传感器和温度传感器 3、ΔP 、P 、T 输入为差压式流量传感器、压力传感器和温度传感器 4、f 输入为频率式流量传感器 5、f 、T 输入为频率式流量传感器和温度传感器 6、f 、P 输入为频率式流量传感器、压力传感器 7、f 、P 、T 输入为频率式流量传感器、压力传感器和温度传感器 8、G 输入为流量传感器(线性流量信号) 9、G 、T 输入流量传感器和温度传感器 10、G 、P 输入为流量传感器和压力传感器 11、G 、T 、P 输入为流量传感器、温度传感器和压力传感器 具有三种补偿功能 温度自动补偿 压力自动补偿 温度和压力自动补偿 显示功能:可显示通道的瞬时流量测量值、本次累积值、累积值、差压测量值、压力补偿测量值、温度补偿测量值及 频率测量值等 PV+SV显示累积流量值为整十一位(0~99999999999字) 当前日期、当前时间显示 流量总累积值断电保持,累积总量满量程(99999999999字)时自动清零,本次累积值断电不保持。
显示差压式、频率式、压力式流量输入系数 参见流量补偿系数Kx的示意图
K3 流量系数3
0~999999
显示差压式、频率式、压力式流量输入系数 参见流量补偿系数Kx的示意图
K4 流量系数4
0~999999
显示差压式、频率式、压力式流量输入系数 参见流量补偿系数Kx的示意图
A1 密度补偿 常 数 A2 密度补偿 系 数 p 工况密度
四、仪表的面板及显示功能
PV显示窗
报警指示灯 确认键
移位键
SV显示窗
减少键 增加键
1)仪表外形尺寸及开孔尺寸
外形尺寸
开孔尺寸
160*80mm(横式) 152*76mm
80*160mm(竖式) 76*152mm
96*96mm(方式)
92*92mm
-2-
4) 操作按键
确认键:数字和参数修改后的确认 翻页键:参数设置下翻键 退出设置键:长按2秒可返回测量画面 配合 键可实现累积流量值清零功能 配合 键可实现设定小数点循环左移功能
位移键:按一次数据向左移动一位 返回键:长按2秒可返回上一级参数
减少键:用于减少数值
带打印功能时,显示时间
显示工况温度常量(当Tin=0,即补偿运算的温度采用 常量时用)
P 工况压力
0~999999
显示工况气体压力常量(当Pin=0,即补偿运算的气体 压力采用常量时用)
-4-
参数
设定范围
disp
DISP
0~7

PV显示器显示
内容选择开关
FS
FS
0~1

流量/热能选择
说 明 diSP=0:轮流显示以下之测量值(参见显示切换) diSP=1:显示当前时间(小时 . 分钟) diSP=2:显示瞬时流量值 diSP=3:显示温度补偿输入值 diSP=4:显示压力补偿输入值 diSP=5:显示流量(差压或频率)测量值。 diSP=6:显示整十一位累积值。 diSP=7:显示本次累积值(复位或断电后 清零。) FS=0:显示瞬时流量,总累积显示流量累积 FS=1:显示瞬时热能,总累积显示热能累积
3)面板指示灯 AL1:第一报警指示灯 AL2:第二报警指示灯 时间:当前时间显示指示灯 瞬时:瞬时流量显示指示灯 温度:温度补偿显示指示灯 压力:压力补偿显示指示灯 流量:差压、流量显示指示灯 本累:本次累积显示指示灯
K2 1.00000
K3 1.00000
K4 1.00000
A1 1.00000
A2 1.00000
ρ 1.00000
ρ 0 1.00000
T 20
P 1.00000
参数 Lo 设定参数禁锁
AL1 第一报警值
设定范围 0~999
仪表上电 自动清零 自动清零 自动清零
-6-
★AL2定量到控制输出:(手动启动,"0"输出)
本次累积流量值 (AL1设定值)
输出200mS 输出200mS
输出200mS AH1提前量
ALM1控制输出
OFF ON OFF ON OFF ON
版本号:5600-090911
系列 NHR-5600系列流量积算控制仪 使用说明书
-、产品介绍 NHR-5600系列流量积算控制仪采用了表面贴装工艺,全自动贴片机生产,具有很强的抗干扰能力。本仪表针对 现场温度、压力、流量等各种信号进行采集、显示、控制、远传、通讯、打印等处理,构成数字采集系统及控 制系统,适用于液体、一般气体、过热蒸汽、饱和蒸汽等的流量积算测量控制。 二、技术规格
AL2 第二报警值
-199999~999999 显示第二报警的报警设定值
A的回差值
AH2
0~999999
第二报警回差
显示第二报警的回差值
K1 流量系数1
0~999999
显示差压式、频率式、压力式流量输入系数 参见流量补偿系数Kx的示意图
K2 流量系数2
0~999999
0~999999 0~999999 0~999999
显示被测量介质的密度补偿常数 显示被测量介质的密度补偿系数 显示被测量介质工作状态下的密度值 ( 单位 : Kg / m3)
p0 标准状况下 的 密 度 T 工况温度
0~999999 0~999999
显示被测量介质在标准状况(1个标准大气压力、20℃时) 下的密度值( 单位 : Kg / m3)
2)显示窗 PV显示窗(整五位显示): 显示瞬时流量值;在参数设定状态下,显示参数符号;可设定为显示流量、压力补偿、温度补偿输入值 SV显示窗(整八位显示): 显示累积流量值;在参数设定状态下,显示设定参数值 PV+SV显示窗(整十一位显示):可设定仪表内部参数,使仪表显示整十一位累积值(累积的百万位显示在 PV显示器后三位)
六、参数设置 6.1 一级参数设置
在工作状态下,按压 键PV显示LOC,SV显示参数数值:按 或 键来进行设置,长按 键2秒可返回上 一级参数,,Loc等于任意参数,按压 键进入一级菜单
-3-
出厂设置 LOC 0
AL1 400
AL2 300
AH1 10
AH2 10
K1 1.00000
增加键:用于增加数值 带打印功能时,用于手动打印
5)仪表配线 仪表在现场布线注意事项: PV 输入 (过程输入) 1. 减小电气干扰,低压直流信号和传感器输入的连线应远离强电走线。如果做不到应采用屏蔽导线,并在一点 接地 2. 在传感器与端子之间接入的任何装置,都有可能由于电阻或漏流而影响测量精度 热偶或高温计输入 应采用与热偶对应的补偿导线作为延长线,最好有屏蔽 RTD(铂电阻)输入 三根导线的电阻必须相同,每根导线电阻不能超过 15Ω
ALM1控制输出
OFF ON OFF ON OFF ON
仪表上电 自动清零 自动清零 自动清零
2、AL2定量控制输出时序图 ★AL2定量过程控制输出:(手动启动,"1"输出)
本次累积流量值 (AL1设定值)
输出200mS 输出200mS 输出200mS AH1提前量
ALM1控制输出
OFF ON OFF ON OFF ON
设定值
设定值
★上限报警输出: ★下限报警输出:
PV测量值
相关文档
最新文档