异丙醇气体变送器
异丙醇检测仪
异丙醇检测仪ADL-600A-C3H8O ————————————————————————————————————————————————————————————————————————————————————————————品牌型号ADL-600A-C3H80检测气体异丙醇化学式C3H80检测原理电化学、催化燃烧、半导体、红外线检测方式气体扩散式、管道式、泵吸式可选安装方式靠墙面安装(离气体泄漏源靠近的地方)显示方式液晶显示(选配功能)报警方式声光报警LED灯+≥85dB(选配功能)继电器1组(1A/24VDC)(选配功能)输出信号RS485通讯信号线制四线制(总线式2电源线2信号线)工作电压24VDC工作电压范围12-30VDC防爆等级ExdⅡCT6Gb工作压力86~106Kpa防护等级IP65精度≤±3%计量证可选响应时间≤30S(T90)外壳材质不锈钢/铝合金铸体重复性≤±2%固定位置2处线性误差≤±2%进线口M20*1.5零点漂移≤±1%(F.S/年)出线口M20*1.5工作温度-20℃~+50℃(特殊要求请咨询)设计寿命2~5年(根据传感器而定)工作湿度≤95%RH无结露出厂恢复有功耗≤1.5W(24V DC)覆盖半径≤7.5米尺寸175mm×140mm×95mm重量约1.5Kg附件说明书、合格证、出货单、包装盒、各一份设计标准GB50493-2009《石油化工企业可燃气体和有毒气体检测报警设计规范》GB12358-2006《作业场所环境气体检测报警仪通用技术要求》执行标准GB3836.1-2010《爆炸性气体环境用电气设备第一部分:通用要求》GB3836.2-2010《爆炸性气体环境用电气设备第二部分:隔爆型“d”》Q/ADL01-2013《安德量科技有限公司企业执行标准》————————————————————————————————————————————————————————————————————————————————————————————■国外原装进口气体传感器,抗干扰强误差率小,提高了产品质量保障性,寿命长2-3年;■采用先进微控制处理器技术,响应速度快,测量精度高,误差率低;■本质安全型电路设计,精巧的电源设计、精湛的防雷设计,安全可靠;■智能化温度和零点补偿算法,大大提升了产品的稳定性和重复性;■大屏液晶显示,24小时在线式检测,实时显示气体浓度;■强大的一体化声光报警功能,声响在80dB以上;■1组继电器(开关量信号)输出,方便扩展风机等其他控制设备联动的使用;■多种标准信号输出,方便介入控制器/PLC/DCS等工控系统;■内置恢复出厂设置按键,避免人员误操作;■支持多种检测量程选择,适用于各种环境项目选型;■操作方便。
空气中异丙醇的测定方法
空气中异丙醇的测定方法(一)聚乙二醇6000柱(直接进样)见正丙醇的气相色谱法(一)。
(二)FFAP柱(溶剂解吸进样)1 原理空气中异丙醇用活性炭管采样后,用异丁醇的二硫化碳溶液解吸,经FFAP柱分离,用氢焰离子化检测器检测。
以保留时间定性,峰高定量。
2 仪器2.1 活性炭管:在长80mm、内径3.5~4.0mm、外径6mm的玻璃管中,分前后、两段装入150mg20~40目椰子壳活性炭,前段100mg,后段50mg,中间用玻璃棉或聚氨酯泡沫塑料隔开,两端用玻璃棉固定,套上塑料帽备用或熔封后保存。
在装管前,应先将活性炭于300~350℃通氮气处理4h。
2.2 采样泵,0~1L/min。
2.3 微量注射器,100,10,1微升。
2.4 具塞试管,5ml。
2.5 气相色谱仪,氢焰离子化检测器,0.41ng异丙醇给出的信噪比不低于3∶1。
色谱柱:柱长2m,内径3~4mm,不锈钢柱。
FFAP:Chromosorb W AW担体=10∶100柱温:70℃汽化室温度:180℃检测室温度:180℃载气(氮气):35ml/min3 试剂3.1 异丙醇,色谱纯。
3.2 解吸溶剂:1%(V/V)异丁醇的二硫化碳溶液。
3.3 FFAP,色谱固定液。
3.4 Chromosorb WAW担体,60~80目。
4 采样在采样现场打开活性炭管,50mg端接采样泵并垂直放置,以0.2L/min的速度抽取2L空气。
采样后将管的两端套上塑料帽,1周内分析。
5 分析步骤5.1 对照试验:将未采过样的活性炭管(2.1,数量为样品总数1/10,至少为1支)按照样品的处理操作同样处理作为空白对照。
5.2 样品处理:将活性炭管中的两段活性炭分别倒入具塞试管(2.4)中,加1ml解吸溶剂(3.2),密塞,不时振摇,解吸1h。
5.3 标准曲线的绘制:于50ml量瓶中,先加入少量解吸溶剂(3.2),用1ml刻度吸管准确量取一定量异丙醇(于20℃时1ml异丙醇的质量为0.7851g)加入量瓶中,再加解吸溶剂(3.2)至刻度,配成一定浓度的贮备液。
异丙醇C3H7OH气体变送器
深圳市圣凯安科技有限公司 NE Sensor 异丙醇C3H7OH气体报警器产品描述异丙醇C3H7OH气体报警器适用于各种工业环境和特殊环境中的异丙醇C3H7OH浓度连续在线检测,仪器采用进口电化学传感器和微控制器技术,具有信号稳定,精度高、重复性好等优点,防爆接线方式适用于各种危险场所。
仪器兼容各种控制报警器、PLC、DCS等控制系统,可以实现远程监视,远程控制,远程报警,计算机数据存储、分析等功能。
特点•现场气体浓度液晶显示;•高精度、长寿命的电化学、红外进口传感器;•强大的软件设置支持,满足客户1.0000-99999之间的任意量程和所有气体检测需求;•可通过控制器或遥控器,免开盖对探测器进行报警点调整、零点调整和目标点标定;•适用于几十种气体检测,可选择显示几十种常见气体名称;•气体单位名称PPM、%LEL、%VOL,可任意设定;•程序运算采用了三位浮点数技术,保证了运算的精度;•在全量程范围内任意设置上、下限报警点;•RS485总线通讯,布线简单方便;•4~20mA电流输出信号,可校正、全隔离,产品抗干扰能力强;•2组常开无源触点输出,用于控制风机或电磁阀的交流接触器;•精巧的电源设计、精湛的防雷设计、纯SMT元件贴片工艺,使得产品性能稳定;•巧妙的结构设计,探测器接线免上螺丝,安装极为简便;产品名称异丙醇C3H7OH报警器C3H7OH/NE-301检测气体异丙醇C3H7OH检测原理催化燃烧原理检测范围0-100%LEL分辨率0.1%LEL检测方式扩散式、泵吸式可选显示方式液晶显示输出信号用户可根据实际要求而定,最远可传输2000米(单芯1mm²屏蔽电缆)①两线制4-20mA电流信号输出(三线制可选)②RS-485数字信号输出,配合RS232转接卡可在电脑上存储数据(选配)③2组继电器输出:无源触电容量220VAC3A,24VDC3A(选配)④报警信号输出:现场声光报警,报警声音:<90分贝(选配)检测精度≤±2%(F.S)重复性≤±1%零点漂移≤±1%(F.S/年)报警方式声、光报警响应时间小于20S恢复时间小于20S防爆类型本质安全型防爆标志Ex ibdIICT4防护等级IP65直接读数PPM、%LEL、%VOL任意设定传感器寿命24个月使用环境温度-20℃~+70℃;相对湿度≤95%RH(非凝露)工作电源24VDC(正常工作电压范围:10~30VDC)外型尺寸(含探枪长度)170×140×80mm重量 1.5Kg壳体材料不锈钢/铝合金。
BHT-DA 温湿度变送器使用说明
BHT-DA型温湿度变送器说明书一、概述BHT-DA型温湿度变送器,采用进口温湿度传感器作为敏感器件,具有测量精度高、响应速度快、抗干扰能力强、长期稳定性好等特点;产品体积小、重量轻、易于安装和维护,标准工业信号输出(0-5V、0-10V、4-20MA),方便与各类控制设备、显示仪表连接,实现温湿度状态在线监测的实用型一体化变送器,可广泛应用于各种需要对空气温湿度进行测量与控制的场合。
二、应用场合本产品适用于:(1) SMT行业温湿度数据监控(2) 电子设备厂温湿度数据监控(3) 冷藏库温湿度监测(4) 仓库温湿度监测(5) 药厂GMP监测系统(6) 环境温湿度监控(7) 电信机房温湿监控(8) 宾馆温湿度监控(9) 档案室温湿度监控(10)智能家居温湿度监控. 其它需要监测温湿度的各种场合等。
三、产品外观尺寸四、技术参数五、型号说明Array六、信号输出七、接线说明温度输出T/B温度负载或仪表地线12~24VDC电源负极湿度输出H/A 湿度负载或仪表电源12~24VDC电源正极敬告:电压或电流输出方式生产时已经按客户订购时的要求进行配置;客户在接线时需认真检查输出信号与采集器或仪表端口的匹配,如变更信号方式,必须将变送器供电电源断电,以免损坏(尤其电压输出不可以接在电流采样端,很可能会导致IC损坏);客户在给变送器接通电源前,需认真检查接线是否正确无误,避免人为损坏,(如接错通电,有可能会导致变送器内部元器件烧坏,影响正常使用);八、安装方式:1、通过外壳左右两侧两个孔位或者顶部红色插销上孔位,用M5螺丝将变送器固定;2、导轨式安装;九、注意事项1、安装时安装位置不要有阳光直射或其他影响温度和湿度测量精度的状况。
2、安装和更换时需关闭电源,接通电源前要检查引线是否正确。
3、初次使用,请在环境中通电平衡约30分钟后再测量,以防由于温差造成测量误差。
4、长期不使用时请放在干燥的环境中保存。
5、产品不宜长期在粉尘、油雾、有机溶剂及腐蚀性气体中使用,(乙)烯酮, 丙酮, 异丙醇,乙醇, 甲苯等已经被证明可以导致湿度读数偏移且大部分情况下是不可逆的。
Polytron3000固定式气体检测变送器
固定式气体检测变送器
产品介绍:
德尔格(德国ä)本安型气体监测仪用于连续监测环境中的毒气和氧气。
它是依据模块化的设计理念开发出的新一代气体监测仪,通过信号与控制器进行通讯。
德尔格(带显示和不带显示) 针对不同气体及量程提供多种不同型号的选择。
安装快速、简单:此监测系统含有一个安装基座(用于机械及电气安装)和ä变送器(变送器电子器件),可节省时间和金钱。
基座可提前安装和接线,调试前有遮雨板保护。
调试时,将ä直接插入基座并由快速释放锁扣固定。
再插入传感器,系统即可投入运行。
操作方便:的操作和维护都十分方便。
经过反复验证的ä配有一个集成数据存储器,存储所有标定信息。
如果需要,ä可使用预标定传感器的数据,或传感器也可在ä内部标定。
适用范围广:拥有非凡的电磁兼容性和多种安装选择,ä适于许多领域——从化学工业到半导体工业等。
防爆保护:通过、、、和认证,温度范围为至℃外壳保护等级()。
部分气体测量范围(更多参数请咨询:):
酸性化合物():
氨气():
三氯化硼():
一氧化碳():
氯气():
乙硼烷():
氰化物():
氢气():
硫化氢():
二氧化氮():
一氧化氮():
有机蒸气:
氧气():
臭氧():
二氧化硫():
1 / 1。
德尔格 polytron2 型号 用户手册说明书
探测环境空气中的毒气或氧气101102可探测气体编号 可探测物质 分子式 编号 可探测物质 分子式 编号 可探测物质 分子式 1 乙醛 CH 3CHO 24 二甲基硫醚 (CH 3)2S 47 环氧丙浣 C 3H 6O 2 乙炔 C 2H 2 25 1-氯-2.3-环氧丙烷 C 2H 3OCH 3Cl 48 n-丙基硫醇 C 3H 7SH 3 丙烯酸 C 2H 3COOH 26 乙醇 C 2H 5OH 49 氧气 O 24 氨气 NH 3 27乙基丙烯酸酯 C 2H 3COOC 2H 5 50 二氧化硫 SO 2 5 五氯化锑 SbCl 5 28 乙烯 C 2H 4 51 硫化氢 H 2S 6 砷化硼 AsH 3 29 环氧乙烷 C 2H 4O 52 氢化硒 H 2Se 7 三氯化硼 BCl 3 30 乙硫醇 C 2H 5SH 53 硅烷 SiH 4 8 溴气 Br 2 31 氟气 F 2 54 四氯化硅 SiCl 4 9 溴化氢 HBr 32 甲醛 HCHO 55 二氧化氮 NO 210 1-3-丁二烯 (C 2H 3)2 33氢化锗 GeH 4 56 一氧化氮 NO 11 丁基丙烯酸酯 C 2H 3COOC 4H 9 34 异丙醇 (CH 3)2CHOH 57 四氢噻吩 C 4H 8S12 丁胺、仲级 C 4H 9NH 2 35异丙胺 (CH 3)2CHNH 2 58 亚硫酰二氯 SOCl 2 13 丁硫醇、叔级 C 4H 9SH 36 异丙硫醇 (CH 3)2CHSH 59 四氯化钛 TiCl 4 14 氯气 Cl 2 37 一氧化碳 CO 60 三氯硅烷 SiHCl 315 二氧化氯 ClO 2 38甲醇 CH 3OH 61 三乙胺 (C 2H 5)3N 16 氯化氢 HCl 39 甲硫醇 CH 3SH 62 三甲胺 (CH 3)3N17 氰化氢 HCN 40 甲基丙烯酸甲酯 C 2H 3(CH 3)COOCH 463 三甲硼烷 B(CH 3)3 18 乙硼烷 B 2H 6 41 一甲胺 CH 3NH 2 64 酯酸乙烯酯 CH 3COOC 2H 319 二氯硅烷 SiH 2Cl 2 42吗啉 C 4H 8ONH 65 乙烯基氯 C 2H 3Cl 20 二乙胺 C 2H 5)2NH( 43 三氯化磷 PCl 3 66 氢气 H 221 二乙胺基乙醇 (C 2H 5)NC 2H 4OH 44 磷化氢 PH367 过氧化氢 H 2O 2 22 二甲胺 (CH 3)2NH 45 磷酰氯 POCl 3 68 四氯化锡 SnCl 4 23 二甲基乙胺 (CH 3)2C 2H 5N 46 丙烯 C 3H 6技术数据 测量范围和测量技术性能取决于内装传感器。
ipa临界温度和临界压力
ipa临界温度和临界压力
IPA临界温度和临界压力是指异丙醇(IPA)在特定条件下的温度和压力值,这些值是衡量异丙醇特性和行为的重要参数。
临界温度是指物质在一定压力下发生相变,从液态转变为气态的最低温度。
对于异丙醇而言,其临界温度通常是指在标准大气压下的最高压力值对应的最低温度,低于此温度时,物质无法完全气化。
而临界压力则是指在临界温度下,物质完全气化所需的压力。
在工业生产和科学实验中,了解物质的临界温度和临界压力是非常重要的,因为它们涉及到物质的相态变化、化学反应、气体分离等多个方面。
以异丙醇为例,其临界温度通常为130°C左右,而临界压力约为4MPa。
这意味着在130°C的温度和4MPa的压力下,异丙醇可以完全气化。
在实际应用中,了解并掌握这些参数有助于更好地控制异丙醇的相态变化和反应过程,优化生产工艺和提高产品质量。
总结来说,IPA临界温度和临界压力是指异丙醇在特定条件下的温度和压力值,这些值是衡量异丙醇特性和行为的重要参数。
了解并掌握这些参数有助于更好地控制异丙醇的相态变化和反应过程,为实际应用提供重要的参考和指导。
光气COCL2气体变送器使用规范 说明书
深圳东日瀛能科技有限公司有毒有害智能气体变送器产品说明书深圳东日瀛能科技有限公司目录1、概况-------------------------------------------------------------------------------22、技术特点-------------------------------------------------------------------------23、技术参数-------------------------------------------------------------------------34、外形尺寸及安装方式----------------------------------------------------------44.1安装位置--------------------------------------------------------------------54.2安装方法--------------------------------------------------------------------55、电气连接-------------------------------------------------------------------------66、负载特性--------------------------------------------------------------------------77、操作说明--------------------------------------------------------------------------87.1LCD显示说明---------------------------------------------------------------87.2按键操作说明---------------------------------------------------------------817.3变送器设置------------------------------------------------------------------98、设备维护--------------------------------------------------------------------------159、注意事项--------------------------------------------------------------------------1510、检测气体一览表----------------------------------------------------------------161.概述固定式气体变送器通过对大气中氧气、可燃气体、有毒有害气体进行连续在线检测及声光报警,不仅对特殊场合气体浓度起到控制作用,对危险现场气体泄漏更有预警作用,及时保护各种现场的生命以及财产安全。
西门子PASCAL CV 3110型压力变送器产品说明书
P RESSURE T RANSMITTER PASCAL CV T YPE S ERIES FOR FOOD /PHARMACEUTICALS /CV 3110BIOTECHNOLOGYSignal output::● 4..20 mA, can be retrofitted with optional HART ®protocol ●PROFIBUS PA ■Function modules●Multifunctional display with 5-segment digital display and bar graph●HART ®protocol●Switching module with 2 floating channels, maximum 1.5 Aswitching current, electrically isolated at all sides, without additional auxiliary power ■Function module replacement on site without recalibration "plug and measure"■Watchdog for electronics modules and measuring cell■Hygienic design according to EHEDG, FDA und GMP recommendations ■Material and surface quality according to the hygienic requirements ■Limits of measuring range 0...80 mbar to 0...40 bar ■Accuracy: < 0.25% (linearity, hysteresis and repeatability)■Turndown 5:1■Explosion protection: II 1/2G EEx ia IIC T6■Medium temperature up to 160 °C■Piezoresistive measuring cell, directly aerated, fully weldedThe pressure transmitter PASCAL CV is suited for measuring the relative and absolute pressures of gases, vapors and liquids. The type series CV3110 has been developed to meet the stringent demands of food processing, pharmaceutical technology, and biotechnology. Special attention has been given to good surface quality. Thus, for instance, roughness values to Ra 0.4 µm can be guaranteed for wetted parts (for welds: Ra < 0.8µm) or the system can be electropolished as well.The modular design of the pressure transmitter allows users to choose the best possible device for his specific operating requirements.PASCAL CV is equipped with a variety of process connections and uses smart module technology for display, switching and communication purposes.These functional modules can be exchanged or extended with ease without having to remove the transmitter from the process.Other designs available●PASCAL CV 3100 for general application●PASCAL CV 3120 for chemical/petrochemical industryProcess connection: all standard screw-in, flange and inline connectionsBasic modulePROFIBUSFunction modulesDisplay moduleHART ®-moduleSwitchingmodule4...20 mAData Sheet: D4-017/2P. 1Rev. 0D3Housing hygienic housing design with screw cap and windowMaterialhousing:stainless steel mat.no. 1.4301window:Macrolon gasket:NBR O-ringConstructiontwo-chamber system, minimum housing volume, excellent moisture and condensate protection Pressure compensation PTFE filter system Degree of protection EN 60529, IP 66Climatic category DIN EN 60721 3-4, 4K4HElectrical connection· screwed terminals 1 mm², cable entry fitting through screwing· circular plug connector M 12Weightstandard device without diaphragm seal and function modules approx. 0.65 kgHousing designConstruction welded designDiaphragm modifications see page 5 or order code Materialstainless steel mat.-no. 1.4404 or 1.4435see order codeSensor piezoresistive measuring element System fillfoodstuff oil FD1 (USDA-H1)according to FDAAmbient temperature -20 to 85°C Process temperature depending on design Allowed storage temperature -40...85 °CNote safety values as per examination certificate!Standard design 12....40 VDC Ex-proof design12....30 VDCInterference emission EN 50081 section 1Noise immunityEN 50082 section 2EU examination certificateII 1/2G EEx ia IIC T6Data Sheet: D4-017/2Housing design Measuring system Signal4...20 mA, two-wire,optional with HART protocol (not yet available)Current range 3.8 - 20.8 mA Current limitation approx. 22 mA Alarm state < 3.6 mA, optional > 21 mA Delay time approx. 160 ms measuring cycle 6 measurements / second Measuring range setting turndown 5:1Damping t 0.0 - 120.0 secondsLoadR <(Ohm)Limit point setting DIN 16086Reference conditions DIN EN 60770-1Calibration position vertical mounting position Linearity errors< 0.15% of span TD 5:1 no changeHysteresis < 0.05% of nominal range Repeatability < 0.05% of nominal range Influence of mounting position < 3.5 mbar Long-term drift < 0.1%/year of nominal range DIN EN 60770-1Temperature effecta)Lower range value / upper range value in range 0...60°C ± 0.15%/10 K of nominal range in range < 0°C, > 60°C ± 0.2%/10 K of nominal range b) process connection (diaphragm seal) depending on design flat diaphragm zero point error DN 25/1"4,8 mbar/10 K DN 32/1 1/2"2,3 mbar/10 K DN 401,6 mbar/10 K DN 50/2"0,6 mbar/10 K inline diaphragm zero point error DN 25/1"9,5 mbar/10 K DN 32/1 1/2"4,1 mbar/10 K DN 403,9 mbar/10 K DN 50/2"3,9 mbar/10 KThe specified zero error for the process connection is a guide value for a standard design. We can provide a detailed system calculation upon request. Systems with reduced diaphragm seal errors are also available.Temperature ranges OutputAccuracyApproval/testsP 0 t 2xt 3xt 4xt 5xte.g. damping t = 10 s = 50 s ~100 %windowsO-ring-seal electronicsfully encapsulated replaceablegasketsensor chamber fully encapsulated (reduced volume)plug connection cable entry fitting U - 12 V 22.5 mA^Process connection separate terminal compartment (reduced volume)terminalspressure sensor with direct connection to atmosphericpressure compensationatmospheric pressurecompensationP. 2100 %63 %Supply limits of measuring range meas. span nominal range: e.g. 1 barData Sheet: D4-017/2Display module (multifunctional display) optional·Module housing made of ABS, encapsulated electronics unit·Many operating mode menus ·5-segment pressure read-out with unit ·Read-out display-pressure (standard)-percent -current-sensor temperature·Bar graph 36 segments = 0...100%·Measuring circuit test (current sensing function)3.55...22.0 mA·Alarm indicator on display·Switching function indicator (with switching module)Switching module, optional·No additional auxiliary power required ·Module housing made of ABS, encapsulated electronics unit · 2 limit values, voltage free, short-circuit-proof ·Switching capacity 50 V DC / 500 mA (Ri < 1.5 Ω)or 30 V DC / 1.5 A (Ri < 0.3 Ω)·Overload indicator: LED red, overload or short-circuit ·Fusible cut-out at overload /short-circuit with automatic reset ·Switch points: 0.0 - 100.0% adjustable Standard: 50.0%·Switching function: maker or breaker, adjustable Standard: breaker ·Device off circuit: contact open ·Hysteresis: 0.0% to 100.0%, adjustable standard: 0.1%falling or rising, adjustable,standard: falling ·Switching rate: 6 Hz·Electrically isolated to all sidesInsulation voltage: 500 V, 2.5 kV/2 sec.·Electrical connection: terminal blocks 1 mm²pluggable with automatic module detection - plug and measure -P. 3Profibus module description and HART ® connection upon request ^pluggable with automatic module detection - plug and measure -Basic module: 4...20 mAData Sheet: D4-017/2Switching modulex = configurable w = factory settingP. 4Data Sheet: D4-017/2Mounting positionHousingProcess connectionsP. 5(short term up to 140°C, 1h)Modifications reservedData Sheet: D4-017/2P. 6- please give additional specifications for models not listed -LABOM Mess- und Regeltechnik GmbH Postfach 12 62 D-27795 Hude Tel. (04408)804-0 Fax: (00408)804-404。
异丙醇变送器
IDG100-C3H8O异丙醇固定式气体检测仪一、产品描述:IDG100系列固定式气体变送器通过对大气中异丙醇进行连续在线检测及声光报警,不仅对特殊场合气体浓度起到控制作用,对危险现场气体泄漏更有预警作用,及时保护各种现场的生命以及财产安全。
仪器广泛应用于石油、化工、冶金、消防、煤矿、电力、船舶、环保、电信、医疗等行业。
IDG100系列检测仪采用进口传感器结合高速、高精度处理电路,具有信号稳定,精度高、重复性好等优点,并且采用防爆设计,适用于各种危险场合。
仪器输出各种标准信号,可以兼容各种报警系统、PLC、DCS等控制系统。
二、产品特性:1、采用各种进口传感器,寿命至少2年2、采用高速、高精度处理电路对传感器信号进行处理,响应速度快、测量精度高,稳定性和重复性好3、仪器自带背光大屏幕显示,直观显示气体浓度、类型、单位等各种参数4、气室独立设计,结合空气动力学,更能快速、准确检测目标气体5、全量程范围温度数字自动跟踪补偿,保证测量准确性6、软件校准加按键设置,操作简单人性化7、具备数据恢复功能,无须担心误操作8、RS485、三线制4-20mA输出,继电器输出和声光报警可选9、可为客户配套WLO Sin气体采集软件,软件具有数据存储、查询、导出功能三、技术参数:检测原理:电化学检测对象:C3H8O异丙醇检测量程:0-100/200/1000ppm分辨率:0.1ppm检测精度:±1%重复精度:±1%响应时间:30S接线方式:M20*1.5内螺纹接线线材:RVVP3*0.75mm2安装方式:壁挂式、管道式、泵吸式壳体材料:铝合金隔爆外壳外形尺寸:125*106*153mm防爆等级:ExdII CT6防护等级:IP65整机重量:1.8Kg工作温度:-20~50℃(特殊要求根据需要定制)工作湿度:10~95%RH非凝露工作电源:24VDC(12-30VDC)工作电流:11mA@24V(毒气和氰化氢),33mA@24V(可燃、红外传感器)输出方式:RS485、三线制4-20mA(可根据客户需求定制GPRS、R2S、WI2SI等无线网络传输方式)报警方式:一组继电器输出(2A@30V)、声光报警(可选)声光报警电流:120mA,80db@1m计量认证:第三方计量认证执行标准:GB15322.1-2003,GB3836.1-2010GB3836.2-2010,GB3836.4-2010四、应用场所石油石化、化工厂、冶炼厂、钢铁厂、煤炭厂、热电厂、医药科研、制药生产车间、烟草公司、环境监测、学校科研、楼宇建设、消防报警、污水处理、工业气体过程控制、锅炉房、垃圾处理厂、隧道施工、输油管道、加气站、地下燃气管道检修、室内空气质量检测、危险场所安全防护等。
Alphasense有毒气体传感器4-20mA变送器用户手册说明书
ALPHASENSE USER MANUAL Page 14-20mA Transmitter for Toxic SensorsUMTOX-1 Issue 41INTRODUCTIONThe Transmitter PCB includes circuitry for a three electrode toxic sensor to convert the µA output signal from the sensor to a 2-wire 4-20mA signal. The transmitter board includes 4 mounting pillars that may be removed if not required.Alphasense 4-20 mA transmitters offer convenience and easy maintenance for toxic sensors:• Transmitters are shipped pre-calibrated for immediate use.• Circuitry includes onboard voltage regulator and uses low power two-wire transmitter systems, allowing the simplest possible wiring format.• Small circuit board size allows smaller sensor housing.• Conformally coated circuit board for environmental protection of circuit.• Low power circuitry with excellent performance means no degradation of sensor performance due to electronics.• Amplification of the sensor signal reduces noise pick-up and RFI/EMI susceptibility. Besides periodic sensor re-calibration, the transmitter electronics require no maintenance throughout the lifetime of the sensor. The sensor can be replaced at the end of the sensor working life. Re-calibration is required when the sensor is changed. See section 6.Please read these instructions to ensure correct installation, use and calibration of your gas sensor/ transmitter.2.1Transmitter SpecificationInput Voltage Required+7.5 to + 35 VDCOutput at zero gas concentration4mA (user adjustable)Output at full-scale20mA (user adjustable)Setability /stability<0.05mA (<0.25% FS)Maximum load @ 20 mA, 24 VDC825 ohms (see note)Supply voltage dependence< ±0.2 % output from +7.5 to +35 VDCConnector 2 pin Molex plug (ref. 22-27-2021)PCB current requirement<100 µAPCB dimensions39mm (dia.) x 19 mm (height)Operating conditions See sensor specificationCalibration (shipped pre-calibrated)multi-turn zero and span potentiometersPower supply protection Diode protection to voltage regulatorNo-power equivalent circuit Electrodes short- circuited via FETUMTOX-1Page 22.2Range/OptionsSensor and transmitter boards are shipped from Alphasense pre-calibrated. You may wish to confirm calibration. Standard available ranges are listed below:Sensor Ordering Code(includes sensor)Full-Scale Gas Concentration(ppm)Gain CO-BF THCO-BF 1000Low CO-BF TLCO-BF 100High H2S-BE THH2S-BE 1000Low H2S-B1THH2S-B1200Low H2S-B1TLH2S-B125High SO2-BF THSO2-BF 100Low SO2-BF TLSO2-BF 20High NO2-B1THNO2-B150High NO2-B1TLNO2-B110High CL2-B1TLCL2-B110HighTable 1Transmitter ordering codeAlthough the sensor and transmitter are pre-calibrated and the ranges are preset, it is possible to change range by adjusting the zero and gain potentiometers, which changes the circuit gain.Different sensors can be fitted to a transmitter board; if the gain is in the same category (low or high), then only re-calibration is necessary. If the sensor gain is different, then contact Alphasense for instructions on how to change range.Nitrogen dioxide and Chlorine (NO 2 and Cl 2) sensors give negative outputs, so Cl 2 and NO 2transmitters (THNO2-B1, TLCL2-B1 and TLNO2-B1) will not accept other sensors (CO,H 2S, SO 2), since they have an additional op amp stage to correct for this inverted output.See section 6.3Set Up3.1Mechanical MountingTransmitters are mounted to your housing using the four pillars pre-mounted to the PCB. Two sets of mounting holes are provided so that the sensor/PCB can be fixed to either the housing top (using the locating holes in the corner of the PCB) or to the base of the housing (using either set of locating holes). Figure 1 below shows mounting hole locations (dimensions are in mm). Figure 2 diagrams the sets of locating holes; normally the outerholes are used for mounting, while the inner e in the same location as the earlier issue of this PCB, allowing backward compatibility with the earlier PCB design.Figure 1. Outer mounting hole locations. Figure 2.Inner and outermounting holes.UMTOX-1 Page 3The pillars are tapped to accept an M3 pan head screw. We recommend a screw length that is at least 8mm to ensure rigid fixing. It is good practice to hold the pillar when screwing into the pillars to stop the pillar from rotating on the PCB. It may be easier to remove the sensor whilst screwing the circuit board pillars to your housing. If you move the pillars, ensure that if mounting to the lid of you housing that you include the washer between the pillar and PCB to ensure correct height of the pillar assembly. See figures 3 and 5.Figure 3. Mounting pillar configuration for .Figure 4. Mounting pillar configuration for attaching to the lid of an enclosure.attaching to the base of an enclosure.Figure 5. Side view of mounting to lid of an enclosure.Figure 6. Side view of mounting to the base of an enclosure.Allow 20 minutes after plugging the sensor back into the board for the output to stabilise.Ensure that the sensor is sealed securely to the top face of your housing. The O-ring supplied with your transmitter sensor should be used to ensure an airtight seal, avoiding any access of toxic or corrosive gases to the circuit board and the housing interior.fitted both sidesUMTOX-1 Page 43.2Connection and WiringPower to the transmitter board is via a Molex 2-pin mini plug (type 22-27-2021: supplied with the transmitter). Connect using a screened, two-core cable to the wires (black is ground, red is positive) by either soldering or using a screw terminal block. Twisted pairs can be used for shorter cable lengths. These leads can be shortened or extended as needed.3.3Power SupplyYour power supply must be between 7.5 and 35 VDC with less than 0.2V ripple.Do not supply mains AC power to this unit: this will destroy the transmitter and void the warranty.The transmitter is protected against incorrect polarity but will not function if you have reversed the power supply wires by connecting the Molex plug incorrectly to the transmitter board socket.When selecting the power supply voltage, you must not exceed the maximum total loop resistance, which includes your measuring resistor used to change the 4-20 mA current into a measured voltage.The transmitter requires a minimum of 7.5 volts to operate; therefore, the maximum potential drop allowed across your sensing resistor and cable is:(power supply voltage) -(7.5V)Assuming full-scale deflection at 20 mA, use Ohm's law to calculate the maximum loop (cable plus sensing resistor) resistance allowed.4Correct Usage and MaintenanceEnsure there is a good gas seal between the sensor and the housing; also if the sample is pumped, then ensure that the flow rate is sufficient. Alternatively, the sample gas can be allowed to diffuse to the front face of the sensor. The table below shows the recommended gas flow rate in standard cubic centimetres per minute (sccm). Higher flow rates may be used, but beware that pulsing flow and higher-pressure drops may lead to more erratic readings.Gas Flow Rate (sccm)CO300 to 500H2S400 to 700SO2400 to 700Cl2, NO2400 to 700Table 2Pumped gas recommended flow ratesThe only maintenance required is changing of the O-ring if it has been exposed to extreme environments for long periods (this O-ring should last the lifetime of the sensor in normal conditions). In addition, if the top dust/oil filter has become badly contaminated then contact Alphasense for replacement dust filter (section 5).UMTOX-1 Page 55Reordering Part NumbersReplacement sensor O-rings and dust/oil filters can be ordered by quoting the part numbers below.Part Number Description033-0002-00Replacement O-ring024-0011-00Self-adhesive dust/oil filterTable 3 Replacement Part Numbering6CalibrationThe 4-20mA transmitter is shipped pre-calibrated to the range shown in Table 1. Periodic re-calibration is required for all gas sensors, especially in safety-critical applications.To Calibrate:1First ensure that the power supply is connected correctly and a tight fitting flow hood is in place.2Ensure that a high quality zero gas source is available (e.g. cylinder of zero air or cleaned and scrubbed compressed air) and a bottle of calibration gas with validated accuracy (see Table 5 below).3Apply zero gas for 10 minutes at the flow rate shown in Table 2. Using a small screwdriver, adjust the zero potentiometer (RP2) until the reading is 4.00 ±0.05 mA.See figure 1, attached to this manual.4Apply test gas for ten minutes; the recommended test gas concentration for calibration is shown below in Table 4. Adjust the span potentiometer (RP1) with a small screwdriver until the reading is within ± 0.05 mA of the Span Calibration Point shown in Table 4 if you are using the recommended concentration.5Although it should not be necessary, it is good practice to recheck the zero after setting the span to ensure that the output is still 4.00 ± 0.05 mA in clean air ("zero gas"). Allow at least 10 minutes for full recovery to zero after the calibration gas has been removed.Transmitter Full-Scale(ppm)Calibration gas(ppm)Span Cal Point(mA)THCO-BF100040010.40TLCO-BF10010020.00THH2S-BE100040010.40THH2S-B120050 8.00TLH2S-B1252016.80THSO2-BF1005012.00TLSO2-BF201012.00THNO2-B1502512.00TLNO2-B110512.00TLCL2-B110512.00 Table 4 4-20 mA Transmitter Span CalibrationUMTOX-1 Page 67WarrantyTransmitters are warranted for two years. Sensors are warranted separately. If you have any difficulties or problems then contact:Customer SupportAlphasense LimitedOak Industrial ParkGreat DunmowEssex CM6 1XN, UKTel: +44 (0) 1371 878048Fax: + 44 (0) 1371 878066email:**********************8 AttachmentsFigure 7Circuit diagram@ Alphasense Limited 4 - 20mA Iss 4αlphasense Ltd3 Oak Industrial Park, Chelmsford Road, Great Dunmow, Essex, CM6 1XNTel:+44(0)1371 87 80 48 Fax: +44(0)1371 87 80 66 e-mail : ******************** web: 。
PCP-20T使用说明书
指导手册pH检测器 / 变送器型号 PCP-20T目录1、开关功能2、运行及pH校正2.1运行步骤2.2校准及pH标准液3、各项操作3.1测量模式下的显示屏选择3.2维修模式操作(1)pH校准(2)测量范围设定(3)pH标准液的选择(4)pH值温度补偿设定(5)手动温度补偿设定(6)电极破裂检测的设置(7)零点偏移设定(8)温度校准设定(9)烧坏设定(10)维修模式下的输出方式设定4、维修5、故障及修理6、规格7、安装指导手册pH检测器 / 变送器型号 PCP-20T(1)主要部分名称9页上图:主要部分名称9页下图:显示细目(2)按键功能(3)按键操作图11页图:按键操作图:设定:显示器显示a: 电源开关 i: 温度标定设定a1: pH测量值(测量范围) i1: 温度标定ON/OFF(T.CAL)a2: 温度测量值或温度设定 i2: 温度增加(T.CAL)a3: mV测量值 i3: 温度减少(T.CAL)a4: 电极零点数据(ZERO) i4: 温度第二次增加(T.CAL)a5: 电极斜率数据(SLOPE)a6: 使用pH标准液(BUF.) j: 烧坏设定a7: pH值温度补偿(T.COEF) j1: 烧坏(B.OUT)a8: 变送系统(OUT/B)k: 维护状态中的输出形式设定b: pH标定 k1: 输出形式(OUT)b1: pH标定(校正/使用标准液) k2: 模型值增加(DU.OUT)b2: 第一点标定(BUF.A) k3: 模型值减少(DU.OUT)b3: 第二点标定(BUF.B) k4: 模型值第二次增加(DU.OUT)c: 测量范围设定c1: 测量范围的上限(RNG.LO)c2: 测量范围的下限(RNG.HI)d: 选择pH标准液d1: 第一点pH标准液(BUF.1)d2: 第二点pH标准液(BUF.2)e: pH值温度补偿设定e1: pH值温度补偿ON/OFF(T.COEF)e2: 温度补偿系数增加(T.COEF)e3: 温度补偿系数减少(T.COEF)e4: 温度补偿系数第二次增加(T.COEF)f: 手动温度补偿设定f1: 手动温度补偿ON/OFF(MAN.TC)f2: 温度补偿增加(MAN.TC)f3: 温度补偿减少(MAN.TC)f4: 温度补偿第二次增加(MAN.TC)g: 电极破裂识别的设定g1: 电极破裂识别(EL.CHK)h: 零点偏移设定h1: 零点偏移ON/OFF(Z.SFT)h2: 零点偏移增加(Z.SFT)h3: 零点偏移减少(Z.SFT)h4: 零点偏移第二次增加(Z.SFT)2.1 运行步骤由下列所示的连续步骤,变送器能够进入例行的操作。
【最新精选】异丙醇脱氢制丙酮
异丙醇脱氢制备丙酮实训装置一、功能简介1、丙酮(Acctone)亦称2-丙酮(2-Propanone),无色透明,易燃,易挥发液体,有微香气味。
分子式C3Vh6O,结构简式(CH3)2CO,分子量58.08,熔点-94.6℃,沸点56.5℃,密度(20℃)0.7898g/cm3.能与水、甲醇、乙醇、乙醚、氯仿、吡啶等混溶,能溶解油脂肪、树脂和橡胶,是制造醋酐、双丙酮醇、氯仿、碘仿、环氧树脂、聚异戊二烯橡胶、甲基丙烯酸甲酯等,是一种重要的溶解原料。
在无烟火药、赛璐珞、醋酯纤维、喷漆等工业中做溶剂。
生产中,丙酮的制备和来源主要有以下几种途径:1、淀粉发酵;2、丙烯水和成异丙醇,再经催化脱氢或催化氧化;3、异丙苯氧化水解;4、丙烯在钯作催化剂液相氧化。
此外,也可从木材干馏而得。
实验室中常用乙酸钙干馏制得。
本实训采用的反应装置是一种典型的气固相催化脱氢工艺。
当市场上异丙醇大量过剩情况下,为寻找出路,它仍有一定的生产意义。
因此通过本实训掌握有关脱氢工艺技术还有实用价值。
2、该实训装置是由反应系统、加料系统、产物计量系统、精制分离系统、压力、温度及计算机采集与控制系统、产物分析系统组成,是一个较完整的工艺生产实验过程,适于实训教学采用。
3、装置的原料易得且价格低廉(可使用工业级的异丙醇),催化剂可自制也可外购(有大量的商品供应),且使用寿命很长:反应温度低,精馏沸点低,节约能耗,全体装置尺寸适中,具有亚中间试验的规模,比之选用其他高温、高压、高能耗实验来说优点特别突出,此实训装置实训教学效果良好。
4、装置的单元操作多,从原料、产物储罐液位测定到反应温度、压力测定,反应条件的影响,转化率、收率的测定、到精馏塔的操作控制、最佳化工工艺条件的选择,都体现了与目前工业装置相似的控制水平,能使学生全面了解与掌握生产工艺和操作技能。
5、本实训的优点是:①催化剂的反应温度较低,易于操作;②精制反应条件易于操作;③产品易于分析;④物料易于购买。
异丙醇汽化热
异丙醇汽化热
异丙醇汽化热是指将异丙醇从液态转化为气态所需要吸收的热量。
异丙醇是一种常见的有机化合物,具有较高的汽化热,约为 42.1 kJ/mol。
这意味着在常温常压下,每摩尔的异丙醇从液态转化为气态需要吸收 42.1 kJ 的热量。
异丙醇的汽化热是由其分子内部的化学键断裂和分子间的相互
作用力消失所引起的。
当异丙醇分子被加热到其沸点时,其分子内部的相互作用力逐渐减弱,分子之间的距离增加,直至分子间的相互作用力完全消失,分子成为自由状态,从而形成气态。
异丙醇的汽化热对于许多工业生产和实验室实验都非常重要。
在工业生产中,异丙醇的汽化热可以用来计算加热异丙醇所需的能量,从而优化生产过程。
而在实验室实验中,可以通过测量异丙醇的汽化热来确定其纯度和热力学性质。
- 1 -。
异丙醇气体密度
异丙醇气体密度
异丙醇的密度0.7855g/cm³。
异丙醇(IPA),又名2-丙醇,是一种有机化合物,化学式是C3H8O,是正丙醇的同分异构体。
为无色透明液体,有似乙醇和丙酮混合物的气味,可溶于水,也可溶于醇、醚、苯、氯仿等多数有机溶剂。
异丙醇是重要的化工产品和原料,主要用于制药、化妆品、塑料、香料、涂料等。
2017年10月27日,世界卫生组织国际癌症研究机构公布的致癌物清单初步整理参考,异丙醇在3类致癌物清单中。
异丙醇用途:
1、作为化工原料,可生产丙酮、过氧化氢、甲基异丁基酮、二异丁基酮、异丙胺、异丙醚、异丙基氯以及脂肪酸异丙酯和氯代脂肪酸异丙酯等。
在精细化工方面,可用于生产硝酸异丙酯,黄原酸异丙酯、亚磷酸三
异丙酯、异丙醇铝以及医药和农药等,也可用于生产二异丙酮、醋酸异丙酯和麝香草酚以及汽油添加剂。
2、作为色谱分析标准物测定钡、钙、铜、镁、镍、钾、钠、锶、亚硝酸、钴等。
3、在电子工业中,可用作清洗去油剂。
4、作为溶剂是工业上比较廉价的溶剂,用途广,能和水自由混合,对亲油性物质的溶解力比乙醇强,可以作为硝基纤维素、橡胶、涂料、虫胶、生物碱等的溶剂,可用于生产涂料、油墨、萃取剂、气溶胶剂等。
还可用作防冻剂、清洁剂、调和汽油的添加剂、颜料生产的分散剂、印染工业的固定剂、玻璃和透明塑料的防雾剂等,用作胶黏剂的稀释剂,还用于防冻剂、脱水剂等。
5、油脂行业中,棉籽油的萃取剂,也可用于动物源性组织膜的脱脂。
异丙醇气体密度
异丙醇气体密度
(原创版)
目录
1.引言
2.异丙醇气体的定义和特性
3.异丙醇气体密度的测量方法
4.异丙醇气体密度的用途
5.结论
正文
1.引言
异丙醇是一种有机化合物,其化学式为 (CH3)2CHOH,是一种无色、
具有特殊气味的液体。
在工业生产和科学研究中,异丙醇常常被用作溶剂、抗冻剂等。
然而,在实际应用中,我们需要了解其物理性质,特别是其气体密度,以便更好地掌握其特性和用途。
2.异丙醇气体的定义和特性
异丙醇气体是指在常温下,异丙醇被加热至其沸点(82.3 摄氏度),从而转变为气体状态。
在常压下,异丙醇气体的沸点为 -2.5 摄氏度,冰点为 -117.5 摄氏度。
其物理特性主要包括:无色、易燃、低毒、具有特殊气味等。
3.异丙醇气体密度的测量方法
测量异丙醇气体密度的方法有多种,其中较为常见的方法包括浮标法、比重瓶法和振动管法等。
这些方法的原理都是基于阿基米德原理,即通过测量气体在液体中的浮力或比重,推算出气体的密度。
4.异丙醇气体密度的用途
异丙醇气体密度在实际应用中有很多用途,例如:
(1)在工业生产中,需要根据异丙醇气体密度来设计设备的工艺参数,以保证生产效率和产品质量;
(2)在科研实验中,通过测量异丙醇气体密度,可以分析和研究其物理性质,为改进材料性能和开发新材料提供理论依据;
(3)在环境保护中,通过对异丙醇气体密度的监测,可以及时发现污染源,为环境保护提供数据支持。
5.结论
异丙醇气体密度是其在实际应用中非常重要的物理性质之一。
气体检测仪产品参数
???检测气体:空气中的氯气(CL 2),量程:0-20ppm?量程范围可根据实际要求而定,精度:<±5%最小读数:,响应时间:≤30秒,传感器寿命:24个月,传感器类型:电化学式,电源:锂电池供电,检测方式:扩散式,工作方式:连续工作200小时,输出信号:三线制4-20mA模拟信号输出,RS485输出(选配),连线方式:便携式显示:大屏幕液晶显示,报警:声光报警,防爆标志:Ex dIICT3,防护等级:IP65,工作温度:-10~40℃(特殊要求根据需要而定),工作湿度:5-90%RH,尺寸:126mm×66mm×32mm,重量:220g
一氧化碳检测仪
产品描述:
一氧化碳体检测变送器是可以应用于一氧化碳气体泄漏场所,采用电化学式技术,具有信号稳定,精度高等优点,方式适用于各种危险场所。
2、产品特性:
先进的微处理器技术,-防爆设计,快速,可信,稳定。锂电池电源供电,RS485输出(选配),标配三线制4-20mA模拟信号输出;,继电器输出(选配)反应速度快,测量精度高,最佳的性能和较低的安装费用,维护费用低。
磷化氢检测仪
产品描述:
磷化氢检测变送器是可以应用于磷化氢泄漏场所,采用电化学式技术,具有信号稳定,精度高等优点,方式适用于各种危险场所。
2、产品特性:
先进的微处理器技术,防爆设计,快速,可信,稳定。锂电池电源供电,反应速度快,测量精度高,最佳的性能和较低费用。
3、技术参数:
检测气体:磷化氢(PH3)量程:0-20-1000PPM,精度:<±5%,最小读数:1PPM,响应时间:≤25秒,传感器寿命:24个月,传感器类型:电化学式,电源:锂电池供电,检测方式:扩散式,工作方式:连续工作200小时,输出信号:三线制4-20mA模拟信号输出,RS485输出(选配),连线方式:便携式显示:大屏幕液晶显示,报警:声光报警,防爆标志:Ex dIICT3,防护等级:IP65,工作温度:-10~40℃(特殊要求根据需要而定),工作湿度:5-90%RH,尺寸:126mm×66mm×32mm,重量:220g
异丙醇饱和蒸汽压的测定(精)
异丙醇饱和蒸汽压的测定实验步骤图1玻璃恒温水浴系统装置图1. 连冷凝管的平衡管(又称等压计);2. 搅拌器;3. 温度计;A为球管;B为U形管1. 装样将平衡管(又称等位计、等压计)内装入适量待测液体异丙醇。
A球管约2/3体积,U形管两边各1/2体积,然后按图装好各部分。
如图1所示。
(各个接头处用短而厚的橡皮管连接,然后再用石蜡密封好,此步骤实验室已装好)。
2.压力计采零,系统气密性检查接通冷凝水,打开平衡阀1和进气阀,所测压力即为当前大气压,按下压力计面板上的采零键,显示值将为00.00数值(大气压被视为零值看待)。
关闭平衡闭1,旋转进气阀使真空泵与缓冲储气泵相通,启动真空泵,使压力表读书为-35—-67KPa,关闭进气阀,停止抽气,观察压力计的示数,如果压力计的示数能在3~5min内维持不变,或显示数字下降值<0.01Kpa/秒,则表明系统不漏气,否则应逐段检查,消除漏气原因。
(注意:在停止抽气时应先把真空泵与大气相通)3. 测定调节恒温槽温度为25℃开启搅拌器匀速搅拌,其目的是使等压计内外温度平衡,抽气减压气泡逸出的速度以一个一个地逸出为宜,不能成串成串地冲出至液体轻微沸腾,此时AB弯管内的空气不断随蒸汽经C管逸出,如此沸腾3~5min,待样品球中的空气被排除后,小心开启平衡阀1缓缓通入空气,直至U形等压计两臂的液面等高为止,并关闭平衡阀1,在压力表上读出压力值。
重复以上操作一次,当压力表上的读书与前一次相比两者差值应不大于±67Pa,此时即可认为样品球与U形等压计液面上的空间已全部为异丙醇的蒸汽所充满。
当空气被排除干净,且体系温度恒定后,依次测定30℃、35℃、40℃、45℃、50℃时的异丙醇的饱和蒸汽压。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
深圳市圣凯安科技有限公司
NE Sensor 异丙醇C3H7OH气体报警器
产品描述
异丙醇C3H7OH气体报警器适用于各种工业环境和特殊环境中的异丙醇C3H7OH浓度连续在线检测,仪器采用进口电化学传感器和微控制器技术,具有
信号稳定,精度高、重复性好等优点,防爆接线方式适用于各种危险场所。
仪器
兼容各种控制报警器、PLC、DCS等控制系统,可以实现远程监视,远程控制,
远程报警,计算机数据存储、分析等功能。
特点
•现场气体浓度液晶显示;
•高精度、长寿命的电化学、红外进口传感器;
•强大的软件设置支持,满足客户1.0000-99999之间的任意量程和所有气体检测需求;
•可通过控制器或遥控器,免开盖对探测器进行报警点调整、零点调整和目标点标定;
•适用于几十种气体检测,可选择显示几十种常见气体名称;
•气体单位名称PPM、%LEL、%VOL,可任意设定;
•程序运算采用了三位浮点数技术,保证了运算的精度;
•在全量程范围内任意设置上、下限报警点;
•RS485总线通讯,布线简单方便;
•4~20mA电流输出信号,可校正、全隔离,产品抗干扰能力强;
•2组常开无源触点输出,用于控制风机或电磁阀的交流接触器;
•精巧的电源设计、精湛的防雷设计、纯SMT元件贴片工艺,使得产品性能稳定;•巧妙的结构设计,探测器接线免上螺丝,安装极为简便;
产品名称异丙醇C3H7OH报警器C3H7OH/NE-301
检测气体异丙醇C3H7OH
检测原理催化燃烧原理
检测范围0-100%LEL
分辨率0.1%LEL
检测方式扩散式、泵吸式可选
显示方式液晶显示
输出信号用户可根据实际要求而定,最远可传输2000米(单芯1mm²屏蔽电缆)
①两线制4-20mA电流信号输出(三线制可选)
②RS-485数字信号输出,配合RS232转接卡可在电脑上存储
数据(选配)
③2组继电器输出:无源触电容量220VAC3A,24VDC3A(选
配)
④报警信号输出:现场声光报警,报警声音:<90分贝(选
配)
检测精度≤±2%(F.S)
重复性≤±1%
零点漂移≤±1%(F.S/年)
报警方式声、光报警
响应时间小于20S
恢复时间小于20S
防爆类型本质安全型
防爆标志Ex ibdIICT4
防护等级IP65
直接读数PPM、%LEL、%VOL任意设定
传感器寿命24个月
使用环境温度-20℃~+70℃;相对湿度≤95%RH(非凝露)
工作电源24VDC(正常工作电压范围:10~30VDC)
外型尺寸(含探枪长度)170×140×80mm
重量 1.5Kg
壳体材料不锈钢/铝合金。