五里堠无功补偿二次电缆清册
发变组二次电缆清册
湘潭电厂二期发变组二次线电缆清册$湘潭电厂二期发电机及主变压器二次线#3发变组机组同期柜#3发电机ECS柜2,3FBZ-402 ZR-KVVP 10*1.5#3发变组机组同期柜#3发电机ECS柜2,3FBZ-402 ZR-KVVP 14*1.5#3发变组机组同期柜#3机发电机出口断路器柜4YH2,3FBZ-148 ZR-KVVP 4*2.5#3发变组机组同期柜#3机发电机出口PT端子箱1YH2,3FBZ-344 ZR-KVVP 4*2.5#3发变组机组同期柜#3机发电机出口断路器端子箱2,3FBZ-147 ZR-KVVP 4*2.5#3发变组机组同期柜#3机热工DEH2,3FBZ-439 ZR-DJYVP 4(2×1.0)#3发变组机组同期柜#3机热工DEH2,3FBZ-438 ZR-DJYVP 2(2×1.0)#3发变组机组同期柜#3机发电机A VR柜3,3FBZ-159 ZR-KVVP 7*2.5#3发变组机组同期柜#3机组电能及辅助继电器屏2,3FBZ-137 ZR-DJYVP 2(2×1.0)#3发变组主变散热器控制箱#3机FECS机组测控柜4,3FBZ-452 ZR-KVVP 14*1.5#3发变组主变散热器控制箱#3机500KV断路器端子箱2,3FBZ-217 ZR-KVVP 4*2.5#3发变组主变地面公共控制箱#3机主变FECS2,3FBZ-251 ZR-KVVP 4*1.5#3发变组主变地面公共控制箱#3机主变FECS2,3FBZ-253A ZR-DJYVP 3(2×1.0)#3发变组主变地面公共控制箱#3机主变FECS2,3FBZ-253B ZR-DJYVP 3(2×1.0)#3发变组主变地面公共控制箱#3机主变FECS2,3FBZ-253C ZR-DJYVP 3(2×1.0)#3发变组变送器柜左侧端子排#3发电机出线小间CT端子箱3,3FBZ-242 ZR-KVVP 7*2.5#3发变组变送器柜左侧端子排#3机FECS机组测控柜3,3FBZ-254 ZR-KVVP 7*2.5#3发变组变送器柜左侧端子排#3发电机出线小间PT端子箱4,3FBZ-343 ZR-KVVP 10*2.5#3发变组变送器柜左侧端子排#3发电机远动RTU柜4,3FBZ-235 ZR-KVVP 7*2.5#3发变组变送器柜左侧端子排#3机FECS机组测控柜2,3FBZ-255 ZR-KVVP 7*2.5#3发变组变送器柜左侧端子排#3发电机ECS柜4,3FBZ-401 ZR-DJYVP 26(2×1.0)#3发变组变送器柜左侧端子排#3机热工电子设备间DEH柜2,3FBZ-435 ZR-DJYVP 6(2×1.0)#3发变组变送器柜左侧端子排#3机热工电子设备间MCS柜2,3FBZ-436 ZR-DJYVP 6(2×1.0)#3发变组变送器柜左侧端子排#3机网控公用测控柜2,3FBZ-216 ZR-DJYVP 5(2×1.0)#3发变组计量回路端子排#3机主变公共端子箱3,3FBZ-163 ZR-KVVP 7*2.5#3发变组计量回路端子排#3机FECS机组测控柜3,3FBZ-256 ZR-KVVP 7*2.5#3发变组计量回路端子排#3发电机出口断路器柜3,3FBZ-137 ZR-KVVP 7*2.5#3发变组计量回路端子排#3机主变500KVPT端子箱3,3FBZ-207 ZR-KVVP 7*2.5#3发变组计量回路端子排#3发电机出口断路器柜4,3FBZ-136 ZR-KVVP 7*2.5#3发变组计量回路端子排#3发电机FECS柜2,3FBZ-257 ZR-KVVP 4*1.5#3发变组辅助继电器回路端子排#3发变组A VR柜2,3FBZ-157 ZR-KVVP 4*1.5#3发变组辅助继电器回路端子排#3发变组A VR柜2,3FBZ-158A ZR-KVVP 4*1.5#3发变组辅助继电器回路端子排#3发变组A VR柜2,3FBZ-158B ZR-KVVP 4*1.5#3发变组辅助继电器回路端子排#3机热工电子设备间MCS柜2,3FBZ-437 ZR-KVVP 4*1.5#3发变组辅助继电器回路端子排#3机远动RTUI/O柜2,3FBZ-158 ZR-KVVP 4*1.5#3发变组辅助继电器回路端子排#3发电机ECS柜2,3FBZ-404 ZR-KVVP 4*1.5#3发变组辅助继电器回路端子排#3发电机断路器柜2,3FBZ-160 ZR-KVVP 4*1.5#3发变组辅助继电器回路端子排#3发电机机组同期柜2,3FBZ-137 ZR-KVVP 4*1.5#3发变组辅助继电器回路端子排#3发变组500KV桥断路器端子箱3,3FBZ-147 ZR-KVVP 7*1.5#3发变组辅助继电器回路端子排#3发电机出口断路器柜4,3FBZ-149A ZR-KVVP 7*1.5#3发变组辅助继电器回路端子排#3发电机ECS柜2,3FBZ-405 ZR-KVVP 4*1.5#3发变组辅助继电器回路端子排#3发电机出口断路器柜4,3FBZ-149B ZR-KVVP 7*1.5#3发变组辅助继电器回路端子排#3发电机ECS柜2,3FBZ-406 ZR-KVVP 4*1.5#3发变组辅助继电器回路端子排#3发电机ECS柜3,3FBZ-407 ZR-KVVP 7*1.5#3发变组故障录波屏左端子排#3发电机出口PT端子箱3,3FBZ-346 ZR-KVVP 7*2.5 #3发变组故障录波屏左端子排#3发电机出口CT端子箱3,3FBZ-245 ZR-KVVP 7*2.5。
1号泄洪洞至进水口配电室二次控制电缆清册 20140330周蓉周丰
19
TLA-D3-903
控制电缆:
ZR-DJYPVP4×(3×1.0)
起始位置:
1号泄洪洞400V室29XB本体温控箱——闸首LCU-2(72D2)
LCU-RTD量:29XB第一二三绕组温度RTD量
20
TLA-D4-903
控制电缆:
ZR-DJYPVP4×(3×1.0)
(保护CT信号)控制电缆;
ZR-KYJVP2-224×2.5
起始位置:
1号泄洪洞400V室30XB本体高压侧零序CT——闸首10kV室VI段30XB高压侧断路器130DL开关柜(74B8)
3
5AH5-702
(保护开入信号)控制电缆;
ZR-KYJVP2-224×2.5
起始位置:
1号泄洪洞400V室29XB本体温控箱——闸首10kV室V段29XB高压侧断路器129DL开关柜(74A5)
起始位置:
闸首10kV室V段29XB高压侧断路器129DL开关柜(74A5)——1号泄洪洞400V室429DL开关柜(81B1)
1号泄洪洞变29XB、30XB高压侧断路器开关柜保护装置保护出口,跳变压器低压侧断路器429DL、430DL
8
6AH8-706
(保护出口跳闸信号)控制电缆;
ZR-KYJVP2-224×4.0
LCU-DI量:29XB、30XB风机运行、温度高、温控箱故障报警信号
24
TLA-D4-901
控制电缆:
ZR-KYJVP2-224×2.5
起始位置:
1号泄洪洞400V室30XB本体温控箱——闸首LCU-2(72D2)
25
2APD3-702
二次电缆清册
电缆起点
电缆终点
长度(m) 敷设情况 电缆头完成情况 65 65 15 15 20 20 10 10 10 65 20 30 10 30 70 20 10
二仙桥
交 流 屏 控 制 信 号 35kV 开关柜 直 流 屏
35kV馈线柜 H13 配电变压器TP1 温度控制器 35kV馈线柜 H23 配电变压器TP2 温度控制器 直流屏 SP 35kV进线柜 H11 直流屏 SP 35kV进线柜 H11 直流屏 SP 35kV进线柜 H21 直流屏 SP 35kV进线柜 H21 直流屏 SP 控制信号屏 CP 直流屏 SP 控制信号屏 CP 直流屏 SP 钢轨电位限制装置 直流屏 SP 400V开关柜内通信节点机 交流屏 AC 35kV进线柜 H11 交流屏 AC 钢轨电位限制装置 OV 交流屏 AC 控制信号屏 CP 交流屏 AC 配电变压器TP1温控器、电磁锁、风机 交流屏 AC 配电变压器TP2温控器、电磁锁、风机 控制信号屏 CP 35kV开关柜H11 控制信号屏 CP 钢轨电位限制装置OV
电缆起点
电缆终点
长度(m) 敷设情况 电缆头完成情况 65 65 15 15 20 20 10 10 10 65 30 70 20 30 10
火车北站
交 流 屏 控 制 信 号 35kV 开关柜 直 流 屏
35kV馈线柜 H13 配电变压器TP1 温器 直流屏 SP 35kV进线柜 H11 直流屏 SP 35kV进线柜 H11 直流屏 SP 35kV进线柜 H21 直流屏 SP 35kV进线柜 H21 直流屏 SP 控制信号屏 CP 直流屏 SP 控制信号屏 CP 直流屏 SP 钢轨电位限制装置 直流屏 SP 400V开关柜内通信节点机 直流屏 SP 配电变压器TP1温控器、电磁锁、风机 直流屏 SP 配电变压器TP2温控器、电磁锁、风机 交流屏 AC 35kV进线柜 H11 交流屏 AC 钢轨电位限制装置 OV 交流屏 AC 控制信号屏 CP
9月关口表数据
四十铺变损耗 义合变损耗 峁上变损耗
0.31% 2.53% 9.07%
绥德县电力局关口表明细
二○一二年九月 馈路表 123城关 125城郊 132辛店 1 1 0 K V 绥 德 变 电 站 121二定 130石家湾 122四十铺 131太中银 124太中银 133永乐线 134万顺线 3516绥铁线 35KV米脂变 3553米四线 102四十铺变 10KV2# 125薛家河 124四十铺 122赵家砭 站用 义合 35KV变 121 吉镇 122 满堂川 123 义合 站用1# 站用2# 近区 反峁 峁上 35KV变 121河底 122枣林坪 站用1# 站用2# 吉镇 主天山 馈 路 表 李家湾 刘山 辛家峁 购榆林 购水电站 总购电 总有功 正无功 总有功 正无功 总有功 正无功 总有功 正无功 总有功 正无功 总有功 正无功 总有功 正无功 总有功 正无功 总有功 正无功 总有功 正无功 总有功 反无功 总有功 正无功 总有功 正无功 总有功 正无功 反无功 总有功 正无功 总有功 正无功 总有功 总有功 正无功 总有功 正无功 反无功 总有功 正无功 总有功 正无功 总有功 总有功 总有功 反无功 总有功 总无功 总有功 总无功 总有功 正无功 总有功 正无功 总有功 总有功 总有功 正无功 总有功 正无功 总有功 正无功 总有功 正无功 总有功 正无功 上月底数 本月底数 差数 倍率 加减电量 换表电量 实用电量 1464000 496000 1928000 728000 1548000 492000 948000 354000 1984000 592000 1312000 536000 72000 40000 120000 66000 1002000 324000 928000 232000 110250 110250 1648500 766500 1639680 724200 428720 102500 100 684240 267600 529140 354900 1230 1607760 439600 387760 73560 360 705320 131800 472960 150800 441.8 645.2 46000 2000 322000 2800 306420 68820 31452 1380 261020 34780 35 302 121000 3000 120000 18600 279000 10000 80000 6000 83500 62500 14672510 368000 15040510 功率因数 0.95 0.94 0.95 0.94 0.96 0.93 0.87 0.88 0.95 0.97 0.71 0.91 0.91 0.97 0.93 0.83 7590
输电线路电缆沟(1)
10.51 8.81 0.46 127.72 263.51 558.29 558.29 1080.00
第 1 页,共 8 页
金陵二期启备电源临时输电线路220kV电缆土建工程 金陵二期启备电源临时输电线路220kV电缆土建工程 220kV
金额单位:元(人民币)
序号 项目名称 定额编号 单位 人工费 22 23 24 25 26 电缆隧道C40 C40 人行道 100厚 沟内铺中砂 钢筋φ10内 钢筋φ10外 YT4-49 YT8-32+33*14 YT8-3 YT4-93 YT4-94 M3 M2 M3 T T 114.31 5.5412 9.09 170.24 152.1 材料费 212.55 16.3752 32.51 2717.14 2643.15 机械费 34.9 1.3677 0.29 95.81 122.62 小计 361.76 23.2841 41.89 2983.19 2917.87 基本直接费 脚手架搭 拆费 1.80% 6.51 0.42 0.75 53.70 52.52 其它直接 费 1.70% 6.15 0.40 0.71 50.71 49.60 现场经费 8.00% 28.94 1.86 3.35 238.66 233.43 间接费 11.87% 42.94 2.76 4.97 354.10 346.35 利润 6.00% 21.71 1.40 2.51 178.99 175.07 人工费调 整 4.16元 24.39 1.18 1.94 36.32 32.45 138.54 3.83 80.04 1098.92 1110.76 材料、机 械差 税金 综合单价 3.44% 21.70 1.21 4.68 171.81 169.18 652.6 36.3 140.9 5166.4 5087.2 574.25 31.53 132.31 4618.91 4553.58 费率下浮 40%后
电气二次设备材料清册
BS16004C-大同市水泥厂35kV输变电新建工程初步设计电气设备材料清册山西元工电力工程设计有限公司二〇一六年六月-1-电气二次设备材料清册表序号设备名称型号及规格单位数量备注1 后台系统含主机、17寸液晶显示器,键盘鼠标、音响报警装置,A4激光打印机,相应配套软件,内嵌五防系统。
套 1 组柜1面2 五防锁具含工程所需电磁锁,电编码锁,刀闸锁具,五防钥匙等;套 13 远动通信柜含远动机2套,GPS对时装置1套,通信管理机1套,交换机1台面 14 公用测控柜公用测控装置1套,综合测控装置1套面 15 主变保护测控柜含主变差动保护装置1套,高后备保护测控装置1套,低后备保护测控装置1套,非电量保护测控装置1套,高低压操作箱各1套,主变综合测控1套,温度变送器等。
面 16 低频低压减载柜低频低压减载装置1套面 135kV 线路保护测控装置套 1 就地安装7 35kV PT微机消谐装置套 1 就地安装8 6kV线路保护测控装置套 2 就地安装9 6kV电容器保护测控装置套 1 就地安装10 6kV PT微机消谐装置套 1 就地安装11 交换机24口套 1 就地安装12 计量柜三相三线0.5S级全电子式多功能电能表电能表3只,电能量采集终端1套面 113 6kV电度表三相三线0.5S级全电子式多功能电能表电能表块 3 就地安装14 交流柜含低压三相四线电能表2块,双电源自动切换装置1套,事故照明切换回路面 115 直流充电馈线柜含监控装置、微机绝缘监测仪、整流模块3×10A,面 116 蓄电池柜电池巡检仪1套、2V、100Ah阀控密封铅酸蓄电池104只面 1-2-序号设备名称型号及规格单位数量备注17 UPS电源柜5kV A逆变电源1套面 118 火灾报警系统套 119 图像监控及安全防护系统含视频监控主机、视频前端处理单元、摄像头、门禁系统、电子围栏、红外对射和管材、线材。
套 120 接地铜排30×4mm2米15021 阻燃电力电缆ZC-VV22- 米200022 控制电缆KVVP22- 米300023 电缆穿管米300-3-。
变电站二次施工与调试流程
变电站二次施工与调试流程曾雄炜施工前准备:做一个变电站,拿到图纸时,要先看好图纸上的设计说明,然后做好审图,看是否符合二次回路原理,是否符合施工标准。
开料单,二次控缆料单与辅材料单。
电缆清册上的电缆要与图纸上的端子排图上核对,标出电缆的起始、终点、长度、型号,做成施工用的电缆清册。
打印线芯帽,直流用白色的,交流用黄色的,线芯较细的用2.5平的,线芯较粗的用4平的。
二次设备进场,检查二次设备外观是否完好,屏内元件是否完好,检查柜子是否和图纸上一致,柜子里的端子是否足够、正确。
现场的交流屏与直流屏应该先进场,配合厂家先做试验,例如电池的充放电试验、模块校验、切换试验。
施工:10kV小母线连接,根据图纸连接小母线。
电缆敷设,根据电缆清册敷设电缆,在头尾两端挂上相应的电缆牌(电缆竖井处也要挂上对应的电缆牌)。
现场应有专人负责检查和记录,防止错放、漏放和重放电缆。
电缆预留长度满足接线要求即可,不宜过长或过短。
电缆在电缆竖井及电缆沟支架上要用统一的扎线及绑扎手法,确保电缆排放整齐、美观。
放完电缆应及时清理电缆沟、盖上电缆沟盖板。
制作电缆头,按照图纸确定接线位置,按顺序排好电缆,剥除电缆外皮,做好接地线,电缆头要用6cm左右、大小适中的黑色热缩管套住,且高度一致。
接线,用万用表对线,确定线芯,套上线芯帽,接入对应端子。
接线应排列整齐,固定牢固,尼龙扎带绑扎高度应一致,每个端子侧接线不宜超过两根,型号不同的线芯不能接在同一端子上。
备用芯应套备用线芯帽。
黄绿接地线应整理整齐,少的单根压接,多的3-5根压接。
检查核对图纸,接完线要对屏柜里的接线与图纸进行核对,与图纸是否相符,不符的应查看回路原理,找出错误并更改。
摇绝缘,电缆绝缘是否符合要求。
贴标签,开关、压板、指示灯、空开上应打印相应的标签并贴上。
调试:给上直流屏控制电源、储能电源或合闸电源,检查一次开关侧储能电源或合闸电源保险是否合上,以免合闸时烧毁合闸线圈。
逐一合上交流屏上开关,查看对应的Ⅰ、Ⅱ回路是否有电。
人民电器 JKG2B、JKW5B低压无功补偿控制器 产品说明书
产品概述JKW(G)系列无功功率自动补偿控制器,以控制物理量不同分JKG与JKW两种,适用于低压配电系统电容器补偿装置的自动调节,使功率因数达到用户预定状态,提高电力变压器的利用效率,减少线损,改善供电的电压值量,从而提高了经济效益与社会效益。
正常工作条件及安装条件□ 海拔:海拔高度不高于2500米;□ 温度:环境温度-25℃~+50℃;□ 湿度:空气湿度在40℃时不超过50%,20℃时不超过90%;□ 安装环境:周围环境无腐蚀性气体,无导电尘埃,无易燃易爆的介质存在;□ 安装地点:无剧烈震动。
特点□ 以无功功率计算投切电容容量、补偿精度高。
□ 功率因数测量精度高,显示范围宽。
□ 初始相位预置(软件调节同名端或电流信号极性)。
□ 具有功率因数与无功功率两种控制模式。
□ 人机界面友好操作方便。
□ 各种控制参数全数字可调节直观使用方便。
□ 具有自动运行与手动运行两种工作方式。
□ 具有过电压和欠电压保护功能。
□ 具有掉电保护功能数据不丢失。
□ 电流信号输入阻抗≤0.01Ω。
主要技术数据选型指南056057接线图总电流互感器电容柜图3 JKG2B(JKW5B)接线图(取样电压380V )图4 JKG2B(JKW5B)接线图(取样电压220V ) 开孔尺寸:162X102(mm )总电流互感器电容柜图5 JKG2B 接线图(取样电压380V )总电流互感器至负载电容柜图8JKG2B 接线图(取样电压220V ) 开孔尺寸:162X102(mm )总电流互感器。
开展“两清理”工作构建输配电设施绿色通道
理 工 作 , 促 指 导 用 户 产 权 的 “ 清 理 ” 理 工 作 ; 电 督 两 治 农
科 负 责 公 司 所 属 农 网 1 V 及 04 k 线 路 和 配 电 变 0k . V
压 器 的 “ 清 理 ” 理 工 作 ; 务 科 负 责 “ 清 理 ” 作 两 治 财 两 工 中的 物 资 和 资 金 保 障 :安 监 科 负 责 全 过 程 监 督 理” 作 的实施 和长效 监管 。 工
《 农村 电- ) O O年第 5期 r2l
根 据 国 家 电 网 公 司 “ 清 理 ” 作 有 关 要 求 。 西 两 工 山 省 河 津 供 电 支 公 司 高 度 重 视 , 着 “ 型 引 路 、 面 推 本 典 全 进 、 极实施 、 续 完善 ” 3作 方 针 。 极开 展 了 “ 积 持 的 2 积 两 清 理 ” 清 理 输 配 电 线 路 标 识 及 编 号 ,清 理 输 配 电设 施 ( 对 地 距 离 , 文 简 称 “ 清 理 ” 工 作 , 合 实 际 工 作 情 本 两 ) 结 况 , 于 实 践 , 于 创 新 , 行 了积 极 有 益 的 探 索 和 尝 勇 敢 进 试 , 累了一些 宝贵 的经验 。 者 将该公 司 “ 清理 ”2 积 笔 两 3 作情 况作 简要介 绍 , 参 考 。 供
案 件 发 生 。 三 是 对 于农 村 线 路 廊 道 和 对 地 ( ) 全 距 房 安 离 问 题 , 方 面 向上 级 反 映 情 况 , 取 网 改 资 金 ; 方 一 争 一
该公 司成立领 导小 组 , 公 司分 管领 导具体 负 责 , 由 精心 组织 , 密安排 , 抓 落实 。 初组织 对全 市城 、 周 狠 年 农
10KV无功补偿试验报告
—5
2500V
合格
二.交流耐压
试验部位
电压(KV)
时间(min)
绝缘电阻(MΩ)
结论
耐压前
耐压后
A-B、C及地
31.5
1
100000
100000
合格
B-A、C及地
31.5
1
100000
100000
C-A、B及地
31.5
1
100000
100000
三. 结论:
调试员:孙 杰、孟大伟、李玉龙日期:2013-11-22
额定电压
11/√3KV
额定输出
400KVar
生产日期
2013.10
相别及编号
A相:1304
B相:1302
C相:1303
生产厂家
西安青洲电力电容器有限公司
一. 绝缘电阻(MΩ):
测试位置
R60S
温度℃
仪器电压
结论
A-B、C及地
100000
—5
2500V
合格
B-A、C及地
100000
—5
2500V
合格
C-A、B及地
GTK1301381
生产日期
2013.9
生产厂家
浙江广天变压器有限公司
一.直流电阻测试(mΩ)
测试绕组
AX
BY
CZ
误差
温度℃
40.92
40.86
40.90
0.15
—5
二. 绝缘电阻及吸收比测试
测试位置
绝缘电阻及吸收比测试(MΩ)
R60S
R15S
K
温度℃
仪器电压
主要设备材料清册(古营集变电)
检索号HDS-B1231C 菏泽曹县古营集110kV输变电工程主要设备材料清册菏泽天润电力勘测设计有限公司工程设计证书电力行业乙级A237010698二O一四年九月菏泽电气一次部分主要设备材料表序号名称型号及规范单位数量备注本期远期一主变压器部分1 主变压器SZ11-50000/110,三相双绕组自冷有载调压型电压比:110±8×1.25%/10.5kV容量比:100/100 接线组别:YN,d11阻抗电压 Uk%=17中性点套管CT100/5A 10P20/30VA1台台 1 32 中性点成套装置台 1 3110kV中性点隔离开关GW13-72.5/630A 附电动操动机构台 1 3110kV中性点避雷器标称放电电流:1.5kA,额定电压72kV,雷电冲击下最大残压:186kV 只 1 3附电动机构CJ6110kV中性点放电间隙及CT 含放电间隙电流互感器:100/5A 5P2020VA套 1 33 钢芯铝铰线LGJ-240/30 米30 45 110kV及中性点设备引线用序号名称型号及规范单位数量备注本期远期4 铜母线TMY-125X10 米40 1205 支柱绝缘子12kV 4kN 只9 276 穿墙套管12 kV I e=4000A只 3 9 二110kV配电装置(一)110kV进线间隔户内GIS,单母线 126kV,2000A,三相共箱间隔2 2电缆或架空进线1 断路器126kV,2000A ,40kA(3s),100kA 附弹簧机构:DC220V 1台2 隔离开关2000A ,40kA ,附电动(电动弹簧)机构:AC220V 2组3 接地开关40kA ,附电动机构:AC220V2组4 快速接地开关40kA ,附电动(电动弹簧)机构:AC220V1组5 电流互感器500-1000-1500/5A 0.2S/30VA,500-1000-1500/5A 5P20/30VA 1组序号名称型号及规范单位数量备注本期远期6 电压互感器1100.1//0.133kV 0.5/3P 15/15VA A相 1只7 带电显示器B相1只8 套管126kV,2000A ,40kA,外绝缘爬距:不小于3150mm 3只9 母线126kV,2000A 三相共箱1套10 就地智能控制柜1面(二)110kV桥间隔户内GIS,单母线 126kV,2000A,三相共箱间隔1 21 断路器126kV,2000A ,40kA(3s),100kA 附弹簧机构:DC220V 1台2 隔离开关2000A ,40kA ,附电动(电动弹簧)机构:AC220V 2组3 接地开关40kA ,附电动机构:AC220V2组序号名称型号及规范单位数量备注本期远期4 电流互感器500-1000-1500/5A 0.5/5P20 30/30V5P20 30VA 1组5 母线126Kv,2000A 三相共箱1套6 就地智能控制柜1面(三)110kV主变间隔户内GIS,单母线 126kV,2000A,三相共箱间隔2 31 隔离开关2000A ,40Ka ,附电动(电动弹簧)机构:AC220V 1组2 接地开关40Ka ,附电动机构:AC220V1组3 电流互感器300-600/5,0.2S/30VA,5P20/30VA 1组4 电缆头TF1.123-11/1 6 只FR1.123-11/0 6 只5 带电显示器B相1只序号名称型号及规范单位数量备注本期远期6 母线126kV,2000A 三相共箱1套7 电缆ZR-YJLW02-64/110-1×400300米8 就地智能控制柜1面(四)母线设备间隔户内GIS,单母线 126kV,2000A,三相共箱间隔2 31 隔离开关2000A ,40Ka ,附电动(电动弹簧)机构:AC220V 1组2 快速接地开关40Ka ,附电动机构:AC220V1组3 检修接地开关40Ka ,附电动机构:AC220V1组4 避雷器102/266Kv,10Ka3只5 电压互感器1100.10.1//0.1333Kv 0.2/0.5/3P 15/15/15VA 3只序号名称型号及规范单位数量备注本期远期6 就地智能控制柜1面(五)110kV主母线筒126kV,2000A 三相共箱米15 15 三10kV配电装置(一)主变进线柜主母线Ie=4000A 面 1 4 带带电显示闭锁装置1 真空断路器12kV,4000A,31.5kA,80kA 配弹簧机构电动机电压:DC220V控制电压:DC220V1台2 电流互感器4000/5A,0.2S/5P20/5P20,30/30/20VA 3只3 氧化锌避雷器:17/45kV 5kA3只4 接地开关:31.5kA /4s3只(二)主变提升柜主母线Ie=4000A 面0 1 带带电显示闭锁装置1 氧化锌避雷器17/45kV 5kA3只序号名称型号及规范单位数量备注本期远期2 接地开关:31.5kA /4s3只(三)电缆出线(电容器)柜主母线Ie=4000A 面12 361 真空断路器12kV,1250A,25kA/4s,40kA 配弹簧机构电动机电压:DC220V控制电压:DC220V 1台2 电流互感器300-600/5A ,5P20/0.5/0.2s,20/15/15VA 3只3 接地开关:25kA /4s3只(四)接地变压器出线柜主母线Ie=4000A 面 1 3带带电显示闭锁装置1 真空断路器12kV,1250A,25kA/4s,63kA 配弹簧机构电动机电压:DC220V控制电压:DC220V 1台2 电流互感器100-200/5A ,0.2S/0.5/5P20,15VA//15VA/20VA 3只序号 名 称 型 号 及 规 范单位数量 备 注本期 远期 3氧化锌避雷器 17/45kV 5kA3只4接地开关:25kA /4s3只(五) 电压互感器、避雷器柜 主母线Ie=4000A面 1 4带带电显示闭锁装置1电压互感器31.0/31.0/31.0/310kV3只2 避雷器 17/45kV5kA3只 3熔断器10kV ,0.5A3只(六) 分段柜主母线Ie=4000A面 12 带带电显示闭锁装置1真空断路器12kV ,4000A ,31.5/4S ,40kA 配弹簧机构 电动机电压:DC220V控制电压:DC220V 1台2电流互感器4000/5A ,0.5/5P20/5P20,20VA/30VA/30VA 3只序号名称型号及规范单位数量备注本期远期(七) 分段提升柜主母线Ie=4000A 面 1 2 (八)铜母线桥3150A 米15 45 四10kV无功补偿装置(一)电容器成套装置套 1 31 成套电力电容器4800kvar1组 12 成套电力电容器3600kvar1组 13 干式铁芯电抗器240/10-5%3台 24 避雷器17/45kV 5kA3只 25 放电线圈11/√3-1.7-1W3只 26 隔离开关12kV,630A,主隔离开关附电动机构, 接地开头附手动机构 1组 27 铝排LMY-63*6.330米28 柜体1套2序号名称型号及规范单位数量备注本期远期(二)高压电力电缆ZR-YJV22-8.7/15kV-3×240 米80 240(三)电缆终端头套 4 12 包括三相五站用变压器、接地变压器、消弧线圈系统(一)接地变消弧线圈成套装置套 1 31 接地变压器DKSC-700/10.5-100/0.4ZNyn11 1台#3接地变不含二次绕组2 消弧线圈成套装置消弧线圈:XHDCZ-630/10.5隔离刀闸:GN24-12/400A避雷器:17/45kV 5kA 1套电压互感器:JDZJ-10Q阻尼电阻器3 消弧线圈控制装置套4 柜体套序号名称型号及规范单位数量备注本期远期(二)高压电力电缆YJV22-8.7/15kV-3×240 米50 150(三)电缆终端头套 2 6 包括三相(四)嵌入式电源箱只8 8(五)检修电源箱XW1-2 只 2 3 六全站接地部分1 镀铜钢棒φ=17.2 L=2.5m 根50 50 主接地网垂直接地极2 扁钢-60×6 米950 950 主接地网水平接地极3 铜排TMY-25×4 米300 350 用于等电位接地4 屏蔽铜缆BV-120 米200 250 用于等电位接地5 屏蔽铜缆BV-50 米300 400 用于等电位接地6 镀锌扁钢-60×6 米 1800 2000 用于设备接地7 镀锌圆钢φ12米850 8508 放热焊接材料初步统计放热焊焊点数量为250个套 1 1七全站照明、动力部分序号名称型号及规范单位数量备注本期远期1 照明配电箱只 1 12 应急照明箱只 1 13 动力配电箱只 1 24 风机控制箱只7 75 室外泛光灯250W 只 4 4(6 钢管φ32 米400 400 八全站电缆1 阻燃控制屏蔽电缆千米11 192 阻燃电力电缆千米1.7 23 电缆护管千米2 2九全站电缆防火部分1 阻火包包 2000 20002 防火隔板m2 150 150序号名称型号及规范单位数量备注本期远期3 防火涂料公斤280 2804 防火有机堵料公斤450 4505 防火无机堵料公斤400 4006 角钢5米150 150十电缆桥架部分1 电缆桥架钢制镀锌吨25 252 成品电缆竖井吨 4 4电气二次部分主要设备材料表序号名称型号及规范单位数量备注本期远期一一体化信息平台系统1 站控层设备1.1 主机兼操作员工作站主机兼操作员主机2台,显示器1台,1套监控软件等套 1 11.2I区数据通信网关机含2台数据通信网关机,2台中心交换机,1台间隔层交换机,1台智能接口装置。
勐野江电气二次控制电缆清册(机组部分)
勐野江电气二次控制电缆清册(机组部分)序号电缆号电缆型号来自屏柜名称至屏柜名称备用芯(米)111000ZR-KYJV22RP2 7×1.5=U01+BCP011#机组进水阀控制屏=U01+GAP031#机组LCU C屏3211001ZR-KYJV22RP2 14×1.5=U01+BCP011#机组进水阀控制屏=U01+GAP021#机组LCU B屏0311002ZR-KYJV22RP2 14×1.5=U01+BCP011#机组进水阀控制屏=U01+GAP021#机组LCU B屏4411003ZR-KYJV22RP2 7×1.5=U01+BCP011#机组进水阀控制屏=U01+GAP021#机组LCU B屏2511004ZR-DJYJPV22RP2-2×2×1.0=U01+BCP011#机组进水阀控制屏=U01+GAP031#机组LCU C屏0611005NH-YJV-2×4=U01+BCP011#机组进水阀控制屏=C01+DCP111#机组直流分屏0711006ZR-KYJV22RP2 4×1.5=U01+PAB011#机组冷却水电动阀控制箱=U01+GAP031#机组LCU C屏1811007ZR-KYJV22RP2 7×1.5=U01+PAB011#机组冷却水电动阀控制箱=U01+GAP011#机组LCU A屏2911008NH-YJV-2×4=U01+PAB011#机组冷却水电动阀控制箱=C01+DCP111#机组直流分屏01011009ZR-KYJV22RP2 4×1.5=U01+PAB011#机组冷却水电动阀控制箱电动蝶阀本体11111010ZRA-YJV22-4×6=U01+PAB011#机组冷却水电动阀控制箱电动蝶阀本体11211011厂家供货24*0.75电缆=U01+BCP011#机组进水阀控制屏=U01+BCP021#机组进水阀阀体分线盒41311012厂家供货19*0.75电缆=U01+BCP011#机组进水阀控制屏=U01+BCP031#机组进水阀液压站分线盒01411013厂家供货3*0.75屏蔽电缆=U01+BCP011#机组进水阀控制屏=U01+BCP031#机组进水阀液压站分线盒11511014厂家供货4*10电缆=U01+BCP011#机组进水阀控制屏液压站油泵01611015厂家供货4*10电缆=U01+BCP011#机组进水阀控制屏液压站油泵01711016ZR-KYJV22RP2 4×1.5=U01+LCB021#机组吸尘装置控制箱=U01+GAP031#机组LCU C屏11811017ZR-KYJV22RP2 7×1.5=U01+LCB021#机组吸尘装置控制箱=U01+GAP021#机组LCU B屏31911018ZR-KYJV22RP2 7×1.5=U01+PAB021#机组冷却水四通阀控制箱四通阀本体12011019ZR-KYJV22RP2 4×1.5=U01+PAB021#机组冷却水四通阀控制箱=U01+GAP031#机组LCU C屏12111020ZR-KYJV22RP2 7×1.5=U01+PAB021#机组冷却水四通阀控制箱=U01+GAP011#机组LCU A屏12211021ZRA-YJV22-4×6=U01+LCB021#机组吸尘装置控制箱吸尘器本体22311022ZRA-YJV22-4×6=U01+PAB021#机组冷却水四通阀控制箱四通阀本体12411023ZRA-YJV22-4×6=U01+PAB031#机组冷却水滤水器控制箱减速电机12511024ZRA-YJV22-4×6=U01+PAB031#机组冷却水滤水器控制箱减速电机12611025ZR-KYJV22RP2 7×1.5=U01+PAB031#机组冷却水滤水器控制箱排污电机22711026ZR-DJYJPV22RP2-2×2×1.0=U01+PAB031#机组冷却水滤水器控制箱差压控制器22811027ZR-KYJV22RP2 4×1.5=U01+PAB031#机组冷却水滤水器控制箱=U01+GAP031#机组LCU C屏12911028ZR-KYJV22RP2 10×1.5=U01+PAB031#机组冷却水滤水器控制箱=U01+GAP011#机组LCU A屏33011029ZR-DJYJPV22RP2-2×2×1.0=U01+PAB031#机组冷却水滤水器控制箱=U01+GAP031#机组LCU C屏2序号电缆号电缆型号来自屏柜名称至屏柜名称备用芯(米)111030NH-YJV-2×4=U01+APP1011#机组自用电APP101柜=C01+DCP111#机组直流分屏0211031ZR-KYJV22RP2 4×1.5=U01+APP1011#机组自用电APP101柜=U01+APP1041#机组自用电APP104柜2311032ZR-KYJV22RP2 4×1.5=U01+APP1011#机组自用电APP101柜=U01+APP1031#机组自用电APP103柜2411033ZR-KYJV22RP2 4×1.5=U01+APP1011#机组自用电APP101柜=U01+APP1031#机组自用电APP103柜0511034ZR-KYJV22RP2 7×1.5=U01+APP1011#机组自用电APP101柜=U01+GAP031#机组LCU C屏3611035ZR-KYJV22RP2 4×1.5=U01+APP1011#机组自用电APP101柜=U01+APP1031#机组自用电APP103柜2711036ZR-KYJV22RP2 4×1.5=U01+APP1011#机组自用电APP101柜=U01+APP1031#机组自用电APP103柜2811037ZR-KYJV22RP2 4×1.5=U01+APP1011#机组自用电APP101柜=U01+APP1041#机组自用电APP104柜2911038ZR-KYJV22RP2 7×1.5=U01+APP1011#机组自用电APP101柜=U01+GAP021#机组LCU B屏21011039ZR-DJYJPV22RP2-2×2×1.0=U01+APP1011#机组自用电APP101柜=U01+GAP021#机组LCU B屏21111040ZR-DJYJPV22RP2-2×2×1.0=U01+APP1011#机组自用电APP101柜=U01+APP1031#机组自用电APP103柜2 1211041ZR-K YJV22RP2 5×2.5=U01+APP1011#机组自用电APP101柜=U01+APP1031#机组自用电APP103柜31311042ZR-KYJV22RP2 5×4=U01+APP1011#机组自用电APP101柜=U01+APP1031#机组自用电APP103柜31411043ZR-KYJV22RP2 4×1.5=U01+APP1031#机组自用电APP103柜=U01+APP1041#机组自用电APP104柜21511044ZR-KYJV22RP2 7×1.5=U01+APP1031#机组自用电APP103柜=U01+GAP031#机组LCU C屏31611045ZR-DJYJPV22RP2-2×2×1.0=U01+APP1031#机组自用电APP103柜=U01+APP1041#机组自用电APP104柜2 1711046ZR-KYJV22RP2 4×1.5=U01+APP1031#机组自用电APP103柜=U01+APP1041#机组自用电APP104柜21811047ZR-KYJV22RP2 10×1.5=U01+APP1031#机组自用电APP103柜=U01+GAP021#机组LCU B屏31911048NH-YJV-2×4=U01+APP1031#机组自用电APP103柜=C01+DCP111#机组直流分屏02011049ZR-KYJV22RP2 5×4=U01+APP1031#机组自用电APP103柜=U01+APP1041#机组自用电APP104柜32111050ZR-KYJV22RP2 5×2.5=U01+APP1031#机组自用电APP103柜=U01+APP1041#机组自用电APP104柜32211051ZR-KYJV22RP2 4×1.5=U01+APP1031#机组自用电APP103柜=U01+APP1041#机组自用电APP104柜02311052ZR-KYJV22RP2 4×1.5=U01+APP1031#机组自用电APP103柜=U01+APP1041#机组自用电APP104柜22411053NH-YJV-2×4=U01+APP1041#机组自用电APP104柜=C01+DCP111#机组直流分屏02511054ZR-KYJV22RP2 7×1.5=U01+APP1041#机组自用电APP104柜=U01+GAP031#机组LCU C屏32611055ZR-KYJV22RP2 7×1.5=U01+APP1041#机组自用电APP104柜=U01+GAP021#机组LCU B屏22711056NH-YJV-2×4=U01+XFB011#机组雨淋阀控制箱=C01+LCP511#机组交流分屏02811057厂家供货电缆=U01+XFB011#机组雨淋阀控制箱火灾报警控制器02911058厂家供货电缆=U01+XFB011#机组雨淋阀控制箱火灾报警控制器03011059厂家供货电缆=U01+XFB011#机组雨淋阀控制箱1#机组雨淋阀组0序号电缆号电缆型号来自屏柜名称至屏柜名称备用芯(米)111060ZR-KYJV22RP2 14×1.5=U01+XFB011#机组雨淋阀控制箱=U01+GAP021#机组LCU B屏4211061ZR-KYJV22RP2 4×1.5=U01+XFB011#机组雨淋阀控制箱火灾报警模块2311062ZR-KYJV22RP2 4×1.5=U01+XFB011#机组雨淋阀控制箱=U01+AKB041#发电机断路器柜2411063ZR-KYJV22RP2 4×1.5=U01+XFB011#机组雨淋阀控制箱=U01+EXP041#机组励磁灭磁屏2511064ZR-KYJV22RP2 5×4=U01+FBB011#机组发电机出口CT 端子箱=U01+GAP031#机组LCU C屏1611065ZR-KYJV22RP2 5×4=U01+FBB011#机组发电机出口CT 端子箱=U01+GEP011#机组调速器电气屏2711066ZR-KYJV22RP2 5×4=U01+FBB011#机组发电机出口CT 端子箱1#发电机出口CT A相1811067ZR-KYJV22RP2 5×4=U01+FBB011#机组发电机出口CT 端子箱1#发电机出口CT B相1911068ZR-KYJV22RP2 5×4=U01+FBB011#机组发电机出口CT 端子箱1#发电机出口CT C相11011069ZR-KYJV22RP2 5×4=U01+FBB021#机组发电机中性点CT端子箱=U01+PRP011#机组发电机保护屏11111070ZR-KYJV22RP2 5×4=U01+FBB021#机组发电机中性点CT端子箱=U01+PRP011#机组发电机保护屏11211071ZR-KYJV22RP2 5×4=U01+FBB021#机组发电机中性点CT端子箱1#发电机中性点CT A相11311072ZR-KYJV22RP2 5×4=U01+FBB021#机组发电机中性点CT端子箱1#发电机中性点CT B相11411073ZR-KYJV22RP2 5×4=U01+FBB021#机组发电机中性点CT端子箱1#发电机中性点CT C相11511074NH-YJV-2×4=U01+PRP011#机组发电机保护屏=C01+DCP111#机组直流分屏01611075NH-YJV-2×4=U01+PRP011#机组发电机保护屏=C01+DCP111#机组直流分屏01711076NH-YJV-2×4=U01+PRP011#机组发电机保护屏=C01+LCP511#机组交流分屏01811077ZR-DJYJPV22RP2-2×2×1.0=U01+PRP011#机组发电机保护屏=U01+GAP021#机组LCU B屏21911078ZR-DJYJPV22RP2-2×2×1.0=U01+PRP011#机组发电机保护屏=U01+EXP011#机组励磁调节器屏22011079ZR-DJYJPV22RP2-2×2×1.0=U01+PRP011#机组发电机保护屏=P01+GPS GPS对时装置22111080ZR-KYJV22RP2 5×4=U01+PRP011#机组发电机保护屏=U01+AKB041#发电机断路器柜12211081ZR-KYJV22RP2 5×4=U01+PRP011#机组发电机保护屏1#机组励磁变高压侧CT12311082ZR-KYJV22RP2-5×2.5=U01+PRP011#机组发电机保护屏=U01+AKB071#发电机PT柜12411083ZR-KYJV22RP2-5×2.5=U01+PRP011#机组发电机保护屏=U01+AKB051#发电机联络PT柜32511084ZR-KYJV22RP2-5×2.5=U01+PRP011#机组发电机保护屏=U01+EXP041#机组励磁灭磁屏32611085ZR-KYJV22RP2 4×1.5=U01+PRP011#机组发电机保护屏=U01+GTB011#机组发电机端子箱32711086ZR-KYJV22RP2 4×1.5=U01+PRP011#机组发电机保护屏=U01+AKB041#发电机断路器柜22811087ZR-KYJV22RP2 4×1.5=U01+PRP011#机组发电机保护屏=U01+EXP041#机组励磁灭磁屏22911088ZR-KYJV22RP2 7×1.5=U01+PRP011#机组发电机保护屏=U01+GAP011#机组LCU A屏23011089ZR-KYJV22RP2 4×1.5=U01+PRP011#机组发电机保护屏=U01+AKB041#发电机断路器柜2序号电缆号电缆型号来自屏柜名称至屏柜名称备用芯(米)111090ZR-DJYJPV22RP2-7×3×1.0=U01+GTB011#机组发电机端子箱=U01+GAP021#机组LCU B屏0211091ZR-DJYJPV22RP2-7×3×1.0=U01+GTB011#机组发电机端子箱=U01+GAP021#机组LCU B屏0311092ZR-DJYJPV22RP2-7×3×1.0=U01+GTB011#机组发电机端子箱=U01+GAP021#机组LCU B屏0411093ZR-DJYJPV22RP2-7×3×1.0=U01+GTB011#机组发电机端子箱=U01+GAP021#机组LCU B屏0511094ZR-DJYJPV22RP2-7×3×1.0=U01+GTB011#机组发电机端子箱=U01+GAP021#机组LCU B屏0611095ZR-DJYJPV22RP2-7×3×1.0=U01+GTB011#机组发电机端子箱=U01+GAP021#机组LCU B屏6711096ZR-DJYJPV22RP2-7×3×1.0=U01+GTB011#机组发电机端子箱=U01+GAP021#机组LCU B屏0811097ZR-DJYJPV22RP2-7×3×1.0=U01+GTB011#机组发电机端子箱=U01+GAP021#机组LCU B屏0911098ZR-DJYJPV22RP2-7×3×1.0=U01+GTB011#机组发电机端子箱=U01+GAP021#机组LCU B屏01011099ZR-DJYJPV22RP2-7×3×1.0=U01+GTB011#机组发电机端子箱=U01+GAP021#机组LCU B屏01111100ZR-DJYJPV22RP2-7×3×1.0=U01+GTB011#机组发电机端子箱=U01+GAP021#机组LCU B屏01211101ZR-DJYJPV22RP2-7×3×1.0=U01+GTB011#机组发电机端子箱=U01+GAP021#机组LCU B屏6机端子箱=U01+GAP021#机组LCU B屏01411103ZR-DJYJPV22RP2-7×3×1.0=U01+GTB011#机组发电机端子箱=U01+GAP021#机组LCU B屏01511104ZR-DJYJPV22RP2-7×3×1.0=U01+GTB011#机组发电机端子箱=U01+GAP021#机组LCU B屏01611105ZR-DJYJPV22RP2-7×3×1.0=U01+GTB011#机组发电机端子箱=U01+GAP021#机组LCU B屏01711106ZR-DJYJPV22RP2-7×3×1.0=U01+GTB011#机组发电机端子箱=U01+GAP021#机组LCU B屏01811107ZR-DJYJPV22RP2-7×3×1.0=U01+GTB011#机组发电机端子箱=U01+GAP021#机组LCU B屏61911108ZR-DJYJPV22RP2-7×3×1.0=U01+GTB011#机组发电机端子箱=U01+GAP021#机组LCU B屏02011109ZR-DJYJPV22RP2-7×3×1.0=U01+GTB011#机组发电机端子箱=U01+GAP021#机组LCU B屏32111110ZR-DJYJPV22RP2-7×3×1.0=U01+GTB011#机组发电机端子箱=U01+GAP021#机组LCU B屏02211111ZR-DJYJPV22RP2-7×3×1.0=U01+GTB011#机组发电机端子箱=U01+GAP021#机组LCU B屏02311112ZR-DJYJPV22RP2-7×3×1.0=U01+GTB011#机组发电机端子箱=U01+GAP021#机组LCU B屏02411113ZR-DJYJPV22RP2-2×3×1.0=U01+GTB011#机组发电机端子箱=U01+GAP021#机组LCU B屏32511114ZR-DJYJPV22RP2-7×3×1.0=U01+GTB011#机组发电机端子箱=U01+GAP021#机组LCU B屏02611115ZR-DJYJPV22RP2-2×3×1.0=U01+GTB011#机组发电机端子箱=U01+GAP021#机组LCU B屏02711116ZR-DJYJPV22RP2-2×3×1.0=U01+GTB011#机组发电机端子箱=U01+GAP021#机组LCU B屏3机端子箱=U01+GBP011#机组测温制动屏02911118ZR-DJYJPV22RP2-2×3×1.0=U01+GTB011#机组发电机端子箱=U01+GBP011#机组测温制动屏03011119ZR-DJYJPV22RP2-7×3×1.0=U01+GTB011#机组发电机端子箱=U01+GBP011#机组测温制动屏0序号电缆号电缆型号来自屏柜名称至屏柜名称备用芯(米)111120ZR-DJYJPV22RP2-2×3×1.0=U01+GTB011#机组发电机端子箱=U01+GBP011#机组测温制动屏0211121ZR-DJYJPV22RP2-2×3×1.0=U01+GTB011#机组发电机端子箱=U01+GBP011#机组测温制动屏3311122ZR-KYJV22RP2 14×1.5=U01+GTB011#机组发电机端子箱=U01+GAP011#机组LCU A屏3411123ZR-DJYJPV22RP2-4×2×1.0=U01+GTB011#机组发电机端子箱=U01+GAP031#机组LCU C屏2511124ZR-KYJV22RP2 4×1.5=U01+GTB011#机组发电机端子箱=U01+GTB021#机组DC24V电源箱0611125ZR-KYJV22RP2 4×1.5=U01+GTB011#机组发电机端子箱=U01+GBP011#机组测温制动屏0711126ZR-DJYJPV22RP2-7×3×1.0=U01+TTB011#机组水轮机端子箱=U01+GAP021#机组LCU B屏0811127ZR-DJYJPV22RP2-2×3×1.0=U01+TTB011#机组水轮机端子箱=U01+GAP021#机组LCU B屏0911128ZR-DJYJPV22RP2-2×3×1.0=U01+TTB011#机组水轮机端子箱=U01+GAP021#机组LCU B屏01011129ZR-DJYJPV22RP2-2×3×1.0=U01+TTB011#机组水轮机端子箱=U01+GBP011#机组测温制动屏01111130ZR-DJYJPV22RP2-2×3×1.0=U01+TTB011#机组水轮机端子箱=U01+GBP011#机组测温制动屏31211131ZR-KYJV22RP2 4×1.5=U01+TTB011#机组水轮机端子箱=U01+GAP011#机组LCU A屏21311132ZR-DJYJPV22RP2-4×2×1.0=U01+TTB011#机组水轮机端子箱=U01+GBP011#机组测温制动屏21411133NH-YJV-2×4=U01+TTB011#机组水轮机端子箱=C01+DCP111#机组直流分屏01511134NH-YJV-2×4=U01+TTB011#机组水轮机端子箱=C01+LCP511#机组交流分屏01611135ZR-KYJV22RP2 7×1.5=U01+TTB011#机组水轮机端子箱=U01+GAP031#机组LCU C屏11711136ZR-KYJV22RP2 4×1.5=U01+TTB011#机组水轮机端子箱=U01+GAP031#机组LCU C屏11811137ZR-KYJV22RP2 10×1.5=U01+TTB011#机组水轮机端子箱=U01+GAP011#机组LCU A屏31911138ZR-KYJV22RP2 4×1.5=U01+TTB011#机组水轮机端子箱=U01+GAP031#机组LCU C屏02011139ZR-DJYJPV22RP2-2×2×1.0=U01+TTB011#机组水轮机端子箱=U01+GAP031#机组LCU C屏02111140ZR-DJYJPV22RP2-4×2×1.0=U01+TTB011#机组水轮机端子箱=U01+GAP031#机组LCU C屏02211141ZR-DJYJPV22RP2-4×2×1.0=U01+TTB011#机组水轮机端子箱=U01+GAP031#机组LCU C屏02311142ZR-DJYJPV22RP2-2×2×1.0=U01+TTB011#机组水轮机端子箱=U01+GBP011#机组测温制动屏02411143ZR-KYJV22RP2 14×1.5=U01+TTB011#机组水轮机端子箱=U01+GTB021#机组DC24V电源箱22511144ZR-KYJV22RP2 4×1.5=U01+TTB011#机组水轮机端子箱=U01+GAP011#机组LCU A屏02611145ZR-KYJV22RP2 4×1.5=U01+TTB011#机组水轮机端子箱=U01+GAP011#机组LCU A屏12711146ZR-DJYJPV22RP2-2×2×1.0=U01+TTB011#机组水轮机端子箱=U01+GAP031#机组LCU C屏02811147ZR-KYJV22RP2 7×1.5=U01+TTB011#机组水轮机端子箱=U01+GAP011#机组LCU A屏12911148ZR-KYJV22RP2 4×1.5=U01+TTB011#机组水轮机端子箱=U01+GTB021#机组DC24V电源箱23011149ZR-KYJV22RP2 14×1.5=U01+TTB011#机组水轮机端子箱=U01+GAP011#机组LCU A屏4序号电缆号电缆型号来自屏柜名称至屏柜名称备用芯(米)111150ZR-KYJV22RP2 14×1.5=U01+TTB011#机组水轮机端子箱=U01+GBP011#机组测温制动屏0211151ZR-KYJV22RP2 10×1.5=U01+TTB011#机组水轮机端子箱=U01+GBP011#机组测温制动屏3311152ZR-KYJV22RP2 7×1.5=U01+TTB011#机组水轮机端子箱=U01+GAP031#机组LCU C屏1411153ZR-DJYJPV22RP2-4×2×1.0=U01+TTB011#机组水轮机端子箱=U01+GAP031#机组LCU C屏0511154ZR-DJYJPV22RP2-4×2×1.0=U01+GBP011#机组测温制动屏=U01+GAP031#机组LCU C屏0611155ZR-DJYJPV22RP2-4×2×1.0=U01+GBP011#机组测温制动屏=U01+GAP031#机组LCU C屏0711156ZR-DJYJPV22RP2-4×2×1.0=U01+GBP011#机组测温制动屏=U01+GAP031#机组LCU C屏0811157ZR-DJYJPV22RP2-4×2×1.0=U01+GBP011#机组测温制动屏=U01+GAP031#机组LCU C屏0911158ZR-DJYJPV22RP2-4×2×1.0=U01+GBP011#机组测温制动屏=U01+GAP031#机组LCU C屏01011159ZR-DJYJPV22RP2-4×2×1.0=U01+GBP011#机组测温制动屏=U01+GAP031#机组LCU C屏01111160ZR-KYJV22RP2 4×1.5=U01+GBP011#机组测温制动屏=U01+GAP031#机组LCU C屏11211161ZR-KYJV22RP2 4×1.5=U01+GBP011#机组测温制动屏=U01+GAP031#机组LCU C屏11311162ZR-KYJV22RP2 4×1.5=U01+GBP011#机组测温制动屏=U01+GAP011#机组LCU A屏21411163ZR-KYJV22RP2 4×1.5=U01+GBP011#机组测温制动屏=U01+GAP011#机组LCU A屏01511164ZR-KYJV22RP2 4×1.5=U01+GBP011#机组测温制动屏=U01+GAP011#机组LCU A屏11611165ZR-KYJV22RP2 7×1.5=U01+GBP011#机组测温制动屏=U01+GAP011#机组LCU A屏31711166ZR-KYJV22RP2 14×1.5=U01+GBP011#机组测温制动屏=U01+GAP011#机组LCU A屏01811167ZR-KYJV22RP2 7×1.5=U01+GBP011#机组测温制动屏=U01+GAP011#机组LCU A屏31911168ZR-KYJV22RP2 5×2.5=U01+GBP011#机组测温制动屏=U01+AKB061#发电机进线PT柜32011169NH-YJV-2×4=U01+GBP011#机组测温制动屏=C01+DCP111#机组直流分屏02111170NH-YJV-2×4=U01+GBP011#机组测温制动屏=C01+LCP511#机组交流分屏02211171ZR-KYJV22RP2-5×2.5=U01+AKB031#发电机PT避雷器柜=L01+EMP02电能计量B屏12311172ZR-KYJV22RP2-5×2.5=U01+AKB031#发电机PT避雷器柜=U01+GAP031#机组LCU C屏22411173ZR-KYJV22RP2-5×2.5=U01+AKB031#发电机PT避雷器柜=C01+GAP02公用LCU B屏12511174NH-YJV-2×4=U01+AKB031#发电机PT避雷器柜=C01+DCP111#机组直流分屏02611175ZR-KYJV22RP2-7×1.5=U01+AKB031#发电机PT避雷器柜=U01+GAP011#机组LCU A屏22711176ZR-KYJV22RP2-4×1.5=U01+AKB031#发电机PT避雷器柜=U01+AKB041#发电机断路器柜22811177ZR-KYJV22RP2-4×1.5=U01+AKB031#发电机PT避雷器柜=U01+AKB011#隔离变分支断路器柜22911178ZR-KYJV22RP2-4×1.5=U01+AKB031#发电机PT避雷器柜=U01+AKB021#厂用变分支断路器柜23011179ZR-DJYJPV22RP2-2×2×1.0=U01+AKB031#发电机PT避雷器柜=U01+GAP021#机组LCU B屏2序号电缆号电缆型号来自屏柜名称至屏柜名称备用芯(米)111180ZR-DJYJPV22RP2-2×2×1.0=U01+AKB031#发电机PT避雷器柜=U01+AKB061#发电机进线PT柜2211181ZR-KYJV22RP2-5×4=U01+AKB041#发电机断路器柜=L01+EMP01电能计量A屏1311182NH-YJV-2×4=U01+AKB041#发电机断路器柜=C01+DCP111#机组直流分屏0411183ZR-KYJV22RP2-4×1.5=U01+AKB041#发电机断路器柜=U01+GAP031#机组LCU C屏1511184ZR-KYJV22RP2-4×1.5=U01+AKB041#发电机断路器柜=U01+GAP011#机组LCU A屏2611185ZR-KYJV22RP2-4×1.5=U01+AKB041#发电机断路器柜=U01+AKB061#发电机进线PT柜2711186ZR-KYJV22RP2-4×1.5=U01+AKB041#发电机断路器柜=B20+PRP01母线保护A屏2811187ZR-KYJV22RP2-4×1.5=U01+AKB041#发电机断路器柜=B20+PRP02母线保护B屏2911188NH-YJV-2×4=U01+AKB041#发电机断路器柜=C01+DCP111#机组直流分屏01011189ZR-KYJV22RP2-4×1.5=U01+AKB041#发电机断路器柜=U01+GAP011#机组LCU A屏11111190ZR-KYJV22RP2-4×1.5=U01+AKB041#发电机断路器柜=U01+GAP011#机组LCU A屏21211191ZR-KYJV22RP2-4×1.5=U01+A KB041#发电机断路器柜=U01+GEP011#机组调速器电气屏21311192ZR-KYJV22RP2-4×1.5=U01+AKB041#发电机断路器柜=U01+EXP011#机组励磁调节器屏21411193ZR-KYJV22RP2-10×1.5=U01+AKB041#发电机断路器柜=U01+GAP011#机组LCU A屏21511194ZR-DJYJPV22RP2-2×2×1.0=U01+AKB041#发电机断路器柜=U01+GAP021#机组LCU B屏21611195ZR-DJYJPV22RP2-2×2×1.0=U01+AKB041#发电机断路器柜=U01+AKB051#发电机联络PT柜21711196ZR-KYJV22RP2-5×2.5=U01+AKB051#发电机联络PT 柜=U01+EXP011#机组励磁调节器屏21811197ZR-KYJV22RP2-5×2.5=U01+AKB051#发电机联络PT 柜=U01+GEP011#机组调速器电气屏21911198NH-YJV-2×4=U01+AKB051#发电机联络PT柜=C01+DCP111#机组直流分屏02011199ZR-KYJV22RP2-7×1.5=U01+AKB051#发电机联络PT 柜=U01+GAP011#机组LCU A屏22111200ZR-KYJV22RP2-5×2.5=U01+AKB061#发电机进线PT 柜=L01+EMP01电能计量A屏12211201ZR-KYJV22RP2-5×2.5=U01+AKB061#发电机进线PT 柜=U01+EXP011#机组励磁调节器屏22311202ZR-KYJV22RP2-5×2.5=U01+AKB061#发电机进线PT 柜=U01+GAP031#机组LCU C屏12411203NH-YJV-2×4=U01+AKB061#发电机进线PT柜=C01+DCP111#机组直流分屏02511204ZR-KYJV22RP2-4×1.5=U01+AKB061#发电机进线PT 柜=U01+GAP011#机组LCU A屏1262811207ZR-DJYJPV22RP2-2×2×1.0=U01+AKB061#发电机进线PT柜=U01+AKB071#发电机PT柜22911208NH-YJV-2×4=U01+AKB071#发电机PT柜=C01+DCP111#机组直流分屏03011209ZR-KYJV22RP2-4×1.5=U01+AKB071#发电机PT柜=U01+GAP011#机组LCU A屏1序号电缆号电缆型号来自屏柜名称至屏柜名称备用芯(米)111210234567891011121314151617181920212224252627282930序号电缆号电缆型号来自屏柜名称至屏柜名称备用芯(米)12345611282ZR-KYJV22RP2-5×2.5=U01+AKB031#发电机PT避雷器柜=U01+EXP011#机组励磁调节器屏2711283ZR-KYJV22RP2-5×2.5=U01+AKB031#发电机PT避雷器柜=U01+GEP011#机组调速器电气屏389112901011121314151617181921222324252627282930序号电缆号电缆型号来自屏柜名称至屏柜名称备用芯(米)122000ZR-KYJV22RP2 7×1.5=U02+BCP012#机组进水阀控制屏=U02+GAP032#机组LCU C屏3222001ZR-KYJV22RP2 14×1.5=U02+BCP012#机组进水阀控制屏=U02+GAP022#机组LCU B屏0322002ZR-KYJV22RP2 14×1.5=U02+BCP012#机组进水阀控制屏=U02+GAP022#机组LCU B屏4422003ZR-KYJV22RP2 7×1.5=U02+BCP012#机组进水阀控制屏=U02+GAP022#机组LCU B屏2522004ZR-DJYJPV22RP2-2×2×1.0=U02+BCP012#机组进水阀控制屏=U02+GAP032#机组LCU C屏0622005NH-YJV-2×4=U02+BCP012#机组进水阀控制屏=C01+DCP122#机组直流分屏0722006ZR-KYJV22RP2 4×1.5=U02+PAB012#机组冷却水电动阀控制箱=U02+GAP032#机组LCU C屏1822007ZR-KYJV22RP2 7×1.5=U02+PAB012#机组冷却水电动阀控制箱=U02+GAP012#机组LCU A屏2922008NH-YJV-2×4=U02+PAB012#机组冷却水电动阀控制箱=C01+DCP122#机组直流分屏01022009ZR-KYJV22RP2 4×1.5=U02+PAB012#机组冷却水电动阀控制箱电动蝶阀本体11122010ZRA-YJV22-4×6=U02+PAB012#机组冷却水电动阀控制箱电动蝶阀本体11222011厂家供货24*0.75电缆=U02+BCP012#机组进水阀控制屏=U02+BCP022#机组进水阀阀体分线盒41322012厂家供货19*0.75电缆=U02+BCP012#机组进水阀控制屏=U02+BCP032#机组进水阀液压站分线盒01422013厂家供货3*0.75屏蔽电缆=U02+BCP012#机组进水阀控制屏=U02+BCP032#机组进水阀液压站分线盒11522014厂家供货4*10电缆=U02+BCP012#机组进水阀控制屏液压站油泵01622015厂家供货4*10电缆=U02+BCP012#机组进水阀控制屏液压站油泵01722016ZR-KYJV22RP2 4×1.5=U02+LCB022#机组吸尘装置控制箱=U02+GAP032#机组LCU C屏11822017ZR-KYJV22RP2 7×1.5=U02+LCB022#机组吸尘装置控制箱=U02+GAP022#机组LCU B屏31922018ZR-KYJV22RP2 7×1.5=U02+PAB022#机组冷却水四通阀控制箱四通阀本体12022019ZR-KYJV22RP2 4×1.5=U02+PAB022#机组冷却水四通阀控制箱=U02+GAP032#机组LCU C屏12122020ZR-KYJV22RP2 7×1.5=U02+PAB022#机组冷却水四通阀控制箱=U02+GAP012#机组LCU A屏12222021ZRA-YJV22-4×6=U02+LCB022#机组吸尘装置控制箱吸尘器本体22322022ZRA-YJV22-4×6=U02+PAB022#机组冷却水四通阀控制箱四通阀本体12422023ZRA-YJV22-4×6=U02+PAB032#机组冷却水滤水器控制箱减速电机12522024ZRA-YJV22-4×6=U02+PAB032#机组冷却水滤水器控制箱减速电机12622025ZR-KYJV22RP2 7×1.5=U02+PAB032#机组冷却水滤水器控制箱排污电机22722026ZR-DJYJPV22RP2-2×2×1.0=U02+PAB032#机组冷却水滤水器控制箱差压控制器22822027ZR-KYJV22RP2 4×1.5=U02+PAB032#机组冷却水滤水器控制箱=U02+GAP032#机组LCU C屏12922028ZR-KYJV22RP2 10×1.5=U02+PAB032#机组冷却水滤水器控制箱=U02+GAP012#机组LCU A屏33022029ZR-DJYJPV22RP2-2×2×1.0=U02+PAB032#机组冷却水滤水器控制箱=U02+GAP032#机组LCU C屏2序号电缆号电缆型号来自屏柜名称至屏柜名称备用芯(米)122030NH-YJV-2×4=U02+APP2012#机组自用电APP201柜=C01+DCP122#机组直流分屏0222031ZR-KYJV22RP2 4×1.5=U02+APP2012#机组自用电APP201柜=U02+APP2042#机组自用电APP204柜2322032ZR-KYJV22RP2 4×1.5=U02+APP2012#机组自用电APP201柜=U02+APP2032#机组自用电APP203柜2422033ZR-KYJV22RP2 4×1.5=U02+APP2012#机组自用电APP201柜=U02+APP2032#机组自用电APP203柜0522034ZR-KYJV22RP2 7×1.5=U02+APP2012#机组自用电APP201柜=U02+GAP032#机组LCU C屏3622035ZR-KYJV22RP2 4×1.5=U02+APP2012#机组自用电APP201柜=U02+APP2032#机组自用电APP203柜2722036ZR-KYJV22RP2 4×1.5=U02+APP2012#机组自用电APP201柜=U02+APP2032#机组自用电APP203柜2822037ZR-KYJV22RP2 4×1.5=U02+APP2012#机组自用电APP201柜=U02+APP2042#机组自用电APP204柜2922038ZR-KYJV22RP2 7×1.5=U02+APP2012#机组自用电APP201柜=U02+GAP022#机组LCU B屏21022039ZR-DJYJPV22RP2-2×2×1.0=U02+APP2012#机组自用电APP201柜=U02+GAP022#机组LCU B屏21122040ZR-DJYJPV22RP2-2×2×1.0=U02+APP2012#机组自用电APP201柜=U02+APP2032#机组自用电APP203柜2 1222041ZR-KYJV22RP2 5×2.5=U02+APP2012#机组自用电APP201柜=U02+APP2032#机组自用电APP203柜31322042ZR-KYJV22RP2 5×4=U02+APP2012#机组自用电APP201柜=U02+APP2032#机组自用电APP203柜31422043ZR-KYJV22RP2 4×1.5=U02+APP2032#机组自用电APP203柜=U02+APP2042#机组自用电APP204柜21522044ZR-KYJV22RP2 7×1.5=U02+APP2032#机组自用电APP203柜=U02+GAP032#机组LCU C屏31622045ZR-DJYJPV22RP2-2×2×1.0=U02+APP2032#机组自用电APP203柜=U02+APP2042#机组自用电APP204柜2 1722046ZR-KYJV22RP2 4×1.5=U02+APP2032#机组自用电APP203柜=U02+APP2042#机组自用电APP204柜21822047ZR-KYJV22RP2 10×1.5=U02+APP2032#机组自用电APP203柜=U02+GAP022#机组LCU B屏31922048NH-YJV-2×4=U02+APP2032#机组自用电APP203柜=C01+DCP122#机组直流分屏02022049ZR-KYJV22RP2 5×4=U02+APP2032#机组自用电APP203柜=U02+APP2042#机组自用电APP204柜32122050ZR-KYJV22RP2 5×2.5=U02+APP2032#机组自用电APP203柜=U02+APP2042#机组自用电APP204柜32222051ZR-KYJV22RP2 4×1.5=U02+APP2032#机组自用电APP203柜=U02+APP2042#机组自用电APP204柜02322052ZR-KYJV22RP2 4×1.5=U02+APP2032#机组自用电APP203柜=U02+APP2042#机组自用电APP204柜22422053NH-YJV-2×4=U02+APP2042#机组自用电APP204柜=C01+DCP122#机组直流分屏02522054ZR-KYJV22RP2 7×1.5=U02+APP2042#机组自用电APP204柜=U02+GAP032#机组LCU C屏32622055ZR-KYJV22RP2 7×1.5=U02+APP2042#机组自用电APP204柜=U02+GAP022#机组LCU B屏22722056NH-YJV-2×4=U02+XFB012#机组雨淋阀控制箱=C01+LCP522#机组交流分屏02822057厂家供货电缆=U02+XFB012#机组雨淋阀控制箱火灾报警控制器02922058厂家供货电缆=U02+XFB012#机组雨淋阀控制箱火灾报警控制器03022059厂家供货电缆=U02+XFB012#机组雨淋阀控制箱2#机组雨淋阀组0序号电缆号电缆型号来自屏柜名称至屏柜名称备用芯(米)122060ZR-KYJV22RP2 14×1.5=U02+XFB012#机组雨淋阀控制箱=U02+GAP022#机组LCU B屏4222061ZR-KYJV22RP2 4×1.5=U02+XFB012#机组雨淋阀控制箱火灾报警模块2322062ZR-KYJV22RP2 4×1.5=U02+XFB012#机组雨淋阀控制箱=U02+AKB042#发电机断路器柜2422063ZR-KYJV22RP2 4×1.5=U02+XFB012#机组雨淋阀控制箱=U02+EXP042#机组励磁灭磁屏2522064ZR-KYJV22RP2 5×4=U02+FBB012#机组发电机出口CT 端子箱=U02+GAP032#机组LCU C屏1622065ZR-KYJV22RP2 5×4=U02+FBB012#机组发电机出口CT 端子箱=U02+GEP012#机组调速器电气屏2722066ZR-KYJV22RP2 5×4=U02+FBB012#机组发电机出口CT 端子箱2#发电机出口CT A相1822067ZR-KYJV22RP2 5×4=U02+FBB012#机组发电机出口CT 端子箱2#发电机出口CT B相1922068ZR-KYJV22RP2 5×4=U02+FBB012#机组发电机出口CT 端子箱2#发电机出口CT C相11022069ZR-KYJV22RP2 5×4=U02+FBB022#机组发电机中性点CT端子箱=U02+PRP012#机组发电机保护屏11122070ZR-KYJV22RP2 5×4=U02+FBB022#机组发电机中性点CT端子箱=U02+PRP012#机组发电机保护屏11222071ZR-KYJV22RP2 5×4=U02+FBB022#机组发电机中性点CT端子箱2#发电机中性点CT A相11322072ZR-KYJV22RP2 5×4=U02+FBB022#机组发电机中性点CT端子箱2#发电机中性点CT B相11422073ZR-KYJV22RP2 5×4=U02+FBB022#机组发电机中性点CT端子箱2#发电机中性点CT C相11522074NH-YJV-2×4=U02+PRP012#机组发电机保护屏=C01+DCP122#机组直流分屏01622075NH-YJV-2×4=U02+PRP012#机组发电机保护屏=C01+DCP122#机组直流分屏01722076NH-YJV-2×4=U02+PRP012#机组发电机保护屏=C01+LCP522#机组交流分屏01822077ZR-DJYJPV22RP2-2×2×1.0=U02+PRP012#机组发电机保护屏=U02+GAP022#机组LCU B屏21922078ZR-DJYJPV22RP2-2×2×1.0=U02+PRP012#机组发电机保护屏=U02+EXP012#机组励磁调节器屏22022079ZR-DJYJPV22RP2-2×2×1.0=U02+PRP012#机组发电机保护屏=P01+GPS GPS对时装置22122080ZR-KYJV22RP2 5×4=U02+PRP012#机组发电机保护屏=U02+AKB042#发电机断路器柜12222081ZR-KYJV22RP2 5×4=U02+PRP012#机组发电机保护屏2#机组励磁变高压侧CT12322082ZR-KYJV22RP2-5×2.5=U02+PRP012#机组发电机保护屏=U02+AKB072#发电机PT柜12422083ZR-KYJV22RP2-5×2.5=U02+PRP012#机组发电机保护屏=U02+AKB052#发电机联络PT柜32522084ZR-KYJV22RP2-5×2.5=U02+PRP012#机组发电机保护屏=U02+EXP042#机组励磁灭磁屏32622085ZR-KYJV22RP2 4×1.5=U02+PRP012#机组发电机保护屏=U02+GTB012#机组发电机端子箱32722086ZR-KYJV22RP2 4×1.5=U02+PRP012#机组发电机保护屏=U02+AKB042#发电机断路器柜22822087ZR-KYJV22RP2 4×1.5=U02+PRP012#机组发电机保护屏=U02+EXP042#机组励磁灭磁屏22922088ZR-KYJV22RP2 7×1.5=U02+PRP012#机组发电机保护屏=U02+GAP012#机组LCU A屏23022089ZR-KYJV22RP2 4×1.5=U02+PRP012#机组发电机保护屏=U02+AKB042#发电机断路器柜2序号电缆号电缆型号来自屏柜名称至屏柜名称备用芯(米)122090ZR-DJYJPV22RP2-7×3×1.0=U02+GTB012#机组发电机端子箱=U02+GAP022#机组LCU B屏0222091ZR-DJYJPV22RP2-7×3×1.0=U02+GTB012#机组发电机端子箱=U02+GAP022#机组LCU B屏0322092ZR-DJYJPV22RP2-7×3×1.0=U02+GTB012#机组发电机端子箱=U02+GAP022#机组LCU B屏0422093ZR-DJYJPV22RP2-7×3×1.0=U02+GTB012#机组发电机端子箱=U02+GAP022#机组LCU B屏0522094ZR-DJYJPV22RP2-7×3×1.0=U02+GTB012#机组发电机端子箱=U02+GAP022#机组LCU B屏0622095ZR-DJYJPV22RP2-7×3×1.0=U02+GTB012#机组发电机端子箱=U02+GAP022#机组LCU B屏6722096ZR-DJYJPV22RP2-7×3×1.0=U02+GTB012#机组发电机端子箱=U02+GAP022#机组LCU B屏0822097ZR-DJYJPV22RP2-7×3×1.0=U02+GTB012#机组发电922098ZR-DJYJPV22RP2-7×3×1.0=U02+GTB012#机组发电机端子箱=U02+GAP022#机组LCU B屏01022099ZR-DJYJPV22RP2-7×3×1.0=U02+GTB012#机组发电机端子箱=U02+GAP022#机组LCU B屏01122100ZR-DJYJPV22RP2-7×3×1.0=U02+GTB012#机组发电机端子箱=U02+GAP022#机组LCU B屏01222101ZR-DJYJPV22RP2-7×3×1.0=U02+GTB012#机组发电机端子箱=U02+GAP022#机组LCU B屏61322102ZR-DJYJPV22RP2-7×3×1.0=U02+GTB012#机组发电机端子箱=U02+GAP022#机组LCU B屏01422103ZR-DJYJPV22RP2-7×3×1.0=U02+GTB012#机组发电机端子箱=U02+GAP022#机组LCU B屏01522104ZR-DJYJPV22RP2-7×3×1.0=U02+GTB012#机组发电机端子箱=U02+GAP022#机组LCU B屏01622105ZR-DJYJPV22RP2-7×3×1.0=U02+GTB012#机组发电机端子箱=U02+GAP022#机组LCU B屏01722106ZR-DJYJPV22RP2-7×3×1.0=U02+GTB012#机组发电机端子箱=U02+GAP022#机组LCU B屏01822107ZR-DJYJPV22RP2-7×3×1.0=U02+GTB012#机组发电机端子箱=U02+GAP022#机组LCU B屏61922108ZR-DJYJPV22RP2-7×3×1.0=U02+GTB012#机组发电机端子箱=U02+GAP022#机组LCU B屏02022109ZR-DJYJPV22RP2-7×3×1.0=U02+GTB012#机组发电机端子箱=U02+GAP022#机组LCU B屏32122110ZR-DJYJPV22RP2-7×3×1.0=U02+GTB012#机组发电机端子箱=U02+GAP022#机组LCU B屏02222111ZR-DJYJPV22RP2-7×3×1.0=U02+GTB012#机组发电机端子箱=U02+GAP022#机组LCU B屏02322112ZR-DJYJPV22RP2-7×3×1.0=U02+GTB012#机组发电2422113ZR-DJYJPV22RP2-2×3×1.0=U02+GTB012#机组发电机端子箱=U02+GAP022#机组LCU B屏32522114ZR-DJYJPV22RP2-7×3×1.0=U02+GTB012#机组发电机端子箱=U02+GAP022#机组LCU B屏02622115ZR-DJYJPV22RP2-2×3×1.0=U02+GTB012#机组发电机端子箱=U02+GAP022#机组LCU B屏02722116ZR-DJYJPV22RP2-2×3×1.0=U02+GTB012#机组发电机端子箱=U02+GAP022#机组LCU B屏32822117ZR-DJYJPV22RP2-2×3×1.0=U02+GTB012#机组发电机端子箱=U02+GBP012#机组测温制动屏02922118ZR-DJYJPV22RP2-2×3×1.0=U02+GTB012#机组发电机端子箱=U02+GBP012#机组测温制动屏03022119ZR-DJYJPV22RP2-7×3×1.0=U02+GTB012#机组发电机端子箱=U02+GBP012#机组测温制动屏0序号电缆号电缆型号来自屏柜名称至屏柜名称备用芯(米)122120ZR-DJYJPV22RP2-2×3×1.0=U02+GTB012#机组发电机端子箱=U02+GBP012#机组测温制动屏0222121ZR-DJYJPV22RP2-2×3×1.0=U02+GTB012#机组发电机端子箱=U02+GBP012#机组测温制动屏3322122ZR-KYJV22RP2 14×1.5=U02+GTB012#机组发电机端子箱=U02+GAP012#机组LCU A屏3422123ZR-DJYJPV22RP2-4×2×1.0=U02+GTB012#机组发电机端子箱=U02+GAP032#机组LCU C屏2522124ZR-KYJV22RP2 4×1.5=U02+GTB012#机组发电机端子箱=U02+GTB022#机组DC24V电源箱0622125ZR-KYJV22RP2 4×1.5=U02+GTB012#机组发电机端子箱=U02+GBP012#机组测温制动屏0722126ZR-DJYJPV22RP2-7×3×1.0=U02+TTB012#机组水轮机端子箱=U02+GAP022#机组LCU B屏0端子箱=U02+GAP022#机组LCU B屏0922128ZR-DJYJPV22RP2-2×3×1.0=U02+TTB012#机组水轮机端子箱=U02+GAP022#机组LCU B屏01022129ZR-DJYJPV22RP2-2×3×1.0=U02+TTB012#机组水轮机端子箱=U02+GBP012#机组测温制动屏01122130ZR-DJYJPV22RP2-2×3×1.0=U02+TTB012#机组水轮机端子箱=U02+GBP012#机组测温制动屏31222131ZR-KYJV22RP2 4×1.5=U02+TTB012#机组水轮机端子箱=U02+GAP012#机组LCU A屏21322132ZR-DJYJPV22RP2-4×2×1.0=U02+TTB012#机组水轮机端子箱=U02+GBP012#机组测温制动屏21422133NH-YJV-2×4=U02+TTB012#机组水轮机端子箱=C01+DCP122#机组直流分屏01522134NH-YJV-2×4=U02+TTB012#机组水轮机端子箱=C01+LCP522#机组交流分屏01622135ZR-KYJV22RP2 7×1.5=U02+TTB012#机组水轮机端子箱=U02+GAP032#机组LCU C屏11722136ZR-KYJV22RP2 4×1.5=U02+TTB012#机组水轮机端子箱=U02+GAP032#机组LCU C屏11822137ZR-KYJV22RP2 10×1.5=U02+TTB012#机组水轮机端子箱=U02+GAP012#机组LCU A屏31922138ZR-KYJV22RP2 4×1.5=U02+TTB012#机组水轮机端子箱=U02+GAP032#机组LCU C屏02022139ZR-DJYJPV22RP2-2×2×1.0=U02+TTB012#机组水轮机端子箱=U02+GAP032#机组LCU C屏02122140ZR-DJYJPV22RP2-4×2×1.0=U02+TTB012#机组水轮机端子箱=U02+GAP032#机组LCU C屏02222141ZR-DJYJPV22RP2-4×2×1.0=U02+TTB012#机组水轮机端子箱=U02+GAP032#机组LCU C屏0机端子箱=U02+GBP012#机组测温制动屏02422143ZR-KYJV22RP2 14×1.5=U02+TTB012#机组水轮机端子箱=U02+GTB022#机组DC24V电源箱22522144ZR-KYJV22RP2 4×1.5=U02+TTB012#机组水轮机端子箱=U02+GAP012#机组LCU A屏02622145ZR-KYJV22RP2 4×1.5=U02+TTB012#机组水轮机端子箱=U02+GAP012#机组LCU A屏12722146ZR-DJYJPV22RP2-2×2×1.0=U02+TTB012#机组水轮机端子箱=U02+GAP032#机组LCU C屏02822147ZR-KYJV22R P2 7×1.5=U02+TTB012#机组水轮机端子箱=U02+GAP012#机组LCU A屏12922148ZR-KYJV22RP2 4×1.5=U02+TTB012#机组水轮机端子箱=U02+GTB022#机组DC24V电源箱23022149ZR-KYJV22RP2 14×1.5=U02+TTB012#机组水轮机端子箱=U02+GAP012#机组LCU A屏4序号电缆号电缆型号来自屏柜名称至屏柜名称备用芯(米)122150ZR-KYJV22RP2 14×1.5=U02+TTB012#机组水轮机端子箱=U02+GBP012#机组测温制动屏0222151ZR-KYJV22RP2 10×1.5=U02+TTB012#机组水轮机端子箱=U02+GBP012#机组测温制动屏3322152ZR-KYJV22RP2 7×1.5=U02+TTB012#机组水轮机端子箱=U02+GAP032#机组LCU C屏1422153ZR-DJYJPV22RP2-4×2×1.0=U02+TTB012#机组水轮机端子箱=U02+GAP032#机组LCU C屏0522154ZR-DJYJPV22RP2-4×2×1.0=U02+GBP012#机组测温制动屏=U02+GAP032#机组LCU C屏0622155ZR-DJYJPV22RP2-4×2×1.0=U02+GBP012#机组测温制动屏=U02+GAP032#机组LCU C屏0722156ZR-DJYJPV22RP2-4×2×1.0=U02+GBP012#机组测温。
无功补偿装置安装单位工程完工资料
工程名称:××× kV变电站工程电气装置安装单位工程名称:无功补偿装置安装单位工程完工资料编制单位:编制日期:无功补偿装置安装单位工程完工资料卷内目录无功补偿装置安装单位工程资料核查项目表电抗器运输冲击记录表号:Q/ CSG表6.0.1电抗器破压前气体压力检查记录表号:Q/ CSG表6.0.2备注:保管期间内,油箱内气体压力检查,距离时间不该超过3~5天(电抗器名称编号)绝缘油实验记录表号:Q/CSG表6.0.3电抗器气体继电器查验记录表号:Q/ CSG表6.0.4(回路名称编号)电抗器器身检查隐蔽前签证电抗器冷却器密封实验签证记录表(回路名称编号)电抗器真空注油及密封实验签证表号:Q/CSG表6.0.7导线液压施工检查记录施工日期:年月日表号:Q/CSG表6.0.8说明:1、主、旁母线以背向主变自左至右分为:1、2、3、…档,每档中左侧三相别离记为:A1、B1、C1,右边三相别离记为:A2、B2、C2。
2、进出线耐张线:母线侧三相别离记为:A1、B1、C1,线路侧三相别离记为A2、B2、C2。
主要技术指标:1、压接后对边距不得超过+0.2mm;2、相邻两模间重叠不该小于5mm;3、压后表面滑腻、无裂纹,管口导线无隆起和松股;4;最大允许弯曲2%L。
注:D为接续管外径,L为接续管全长。
箱柜基础检查记录表表号:(回路名称编号)电容器组安装签证表号Q/CSG表6.0.10(回路名称编号)组合式油浸电容器安装签证表号:Q/CSG表6.0.11无功补偿装置安装单位工程质量验收评定表工程编号:6 表号:Q/CSG 表6(回路名称编号)干式电抗器安装分部工程质量验收评定表工程编号:6-1 表号:Q/CSG 表干式电抗器安装分项工程质量查验评定表工程编号:6-1-1 表号:Q/CSG 表6.1.1工程编号:6-1-2 表号:硬母线安装分项工程质量查验评定表工程编号:6-1-2 表号:引下线及设备连线安装分项工程质量查验评定表工程编号:6-1-3 表号:引下线及设备连线安装分项工程质量查验评定表工程编号:6-1-3 表号:Q/CSG 表6.1.3续油浸电抗器安装分部工程质量验收评定表工程编号:6-2 表号:Q/CSG表油浸电抗器本体安装分项工程质量查验评定表工程编号:6-2-1 表号:Q/CSG表6.2.1油浸电抗器器身检查分项工程质量查验评定表工程编号:6-2-2 表号:Q/CSG表6.2.2工程编号:6-2-3 表号:Q/CSG表6.2.3油浸电抗器附件安装分项工程质量查验评定表工程编号:6-2-3 表号:油浸电抗器附件安装分项工程质量查验评定表工程编号:6-2-3 表号:Q/CSG 表6.2.3续2油浸电抗器注油及密封实验分项工程质量查验评定表工程编号:6-2-4 表号:Q/CSG表6.2.4油浸电抗器整体检查分项工程质量查验评定表工程编号:6-2-5表号:工程编号:6-2-6 表号:中性点电抗器安装分项工程质量查验评定表工程编号:6-2-6 表号:Q/CSG 表6.2.6续中性点管形母线安装分项工程质量查验评定表工程编号:6-2-7.1 表号:Q/CSG表6.2.7-1中性点管形母线安装分项工程质量查验评定表工程编号:6-2-7.1 表号:Q/CSG 表6.2.7-1续中性点软母线安装分项工程质量查验评定表工程编号:6-2-7.2 表号:中性点软母线安装分项工程质量查验评定表工程编号:6-2-7.2 表号:Q/CSG引下线及设备连线安装分项工程质量查验评定表工程编号:6-2-8 表号:Q/CSG表6.2.8引下线及设备连线安装分项工程质量查验评定表工程编号:6-2-8 表号:Q/CSG 表6.2.8续控制柜及端分项工程质量查验评定表子箱安装工程编号:6-2-9 表号:Q/CSG表6.2.9二次回路检查及接线分项工程质量查验评定表工程编号:6-2-10 表号:Q/CSG表6.2.10二次回路检查及接线分项工程质量查验评定表工程编号:6-2-10 表号:Q/CSG表6.2.10续(回路名称编号)电容器距离安装分部工程质量验收评定表工程编号:6-3 表号:电容器组安装分项工程质量查验评定表工程编号:6-3-1 表号:Q/CSG表6.3.1。
变电二次现场勘察收资清单
厂家、型号、图纸,投运时间
照片
纸质文件
27
原交流电源
照片
纸质文件
28
建设方意见
用笔记
3
摄像头
个数、位置
4
计量屏
每块表照片、精度、电量采集终端位置
照片
纸质文件
5
断路器
前期断路器厂家、型号、端子箱
照片
纸质文件
6
主变
名牌、厂家
7
电缆
电缆沟是铜牌还是铜缆
照片
纸质文件
8
陪同人电话号码
照片
纸质文件
9
主接线
哪些是负载、哪些是电源,线路是否有线路PT,检同期(电源)、检无压(负荷)
照片
纸质文件
10
厂家、型号、图纸,投运时间
照片
纸质文件
21
原220kV备自投装置
厂家、型号、图纸,投运时间
照片
纸质文件
22
原10kV分段备自投
厂家、型号、图纸,投运时间
照片
纸质文件
23
原电能表屏
图纸
照片
纸质文件
24原ELeabharlann TU厂家、型号、图纸,投运时间
照片
纸质文件
25
原GPS
厂家、型号、图纸,投运时间
照片
纸质文件
26
照片
纸质文件
15
原220kV录波
厂家、型号、图纸,投运时间
照片
纸质文件
16
原主变录波
厂家、型号、图纸,投运时间
照片
纸质文件
17
原110kV录波
厂家、型号、图纸,投运时间
照片
纸质文件
探析电气自动化中无功补偿技术要点_8
探析电气自动化中无功补偿技术要点发布时间:2022-09-12T07:54:59.915Z 来源:《中国电业与能源》2022年第9期作者:皋德华周亮亮陈爱辉包嘉楠[导读] 在电气自动化中应用无功补偿技术,需要采用提升电力负载功率的形式,对线路电能损耗进行控制,以提升能源的利用率,并起到节约成本的作用皋德华周亮亮陈爱辉包嘉楠江苏射阳港发电有限责任公司224000;南通安派电气科技有限公司226000摘要:在电气自动化中应用无功补偿技术,需要采用提升电力负载功率的形式,对线路电能损耗进行控制,以提升能源的利用率,并起到节约成本的作用,由此,为了提升电气自动化中无功补偿技术的应用策略,需要首先明确电气自动化发展中应用无功补偿技术的意义,再了解国内发电厂对相关技术的评价,最后根据实际提出电气自动化中合理应用无功补偿的策略,有供参考。
关键词:电气自动化;无功补偿技术;要点当代电气自动化技术发展迅速,无功补偿设备的应用范围越来越大,其可促使电气功率因数增加,从而有效控制高峰时段的用电负荷,也就更有利于保障电力系统安全稳定的持续运行。
在选择无功补偿设备时,应该注意应用合理的方式,控制其中的电能消耗,以提升电网质量,而若补偿装置不能与供电网络应用需求相符合,则可能导致电压起伏以及谐波等问题出现。
由此可见,针对电气自动化中无功补偿技术要点进行探究具有重要意义。
一、电气自动化发展中应用无功补偿技术的意义当代我国经济和科技均处于高速发展的状态中,电气自动化技术的应用也越来越广泛,例如变电站、高速电气化铁路牵引系统等,均属于需要大幅度应用电气自动化技术的行业,但是从实际上来看,该项技术虽然具有较高的应用价值,但也在同时存在负荷变化复杂等不足之处,易导致系统中出现负序、谐波增加等情况,还能在一定程度上导致无功功率增加,不仅不利于保障电力系统整体的安全性,还易导致资源利用率受到影响,使系统经济效益的提升受到限制。
根据目前的情况来看,在电机自动化系统之中,最为显著的三方面问题分别为无功、负序、谐波,此类问题在国外已经得到了一定程度的解决,但是因为我国人口数量众多,所以变电站的电气自动化应用压力相对更大,其中可能出现的问题也就更多,特别是非线性问题显著,而若能够在其中合理应用无功补偿技术,则有利于针对电气自动化系统中存在的各类非线性问题进行有效解决[1]。
农网变电站及配电线路的无功补偿
,
。
组不应与 配电变 压器 同台架 设 并使 用 同一 组跌落式熔 断 器
,
,
。
! Η 对 于 沿 主 干线负荷 非均匀 分布 的 复杂情况
当分支线
补偿 电容 器 组 中 性点 不 应直 接 接地 避 免 电 容器组 某相 贯 穿性击穿 引 起线 路 相 间短路
,
夹 角时 分 散补偿 电容 器 容量 约为全 线无 功
,
原 则 尽 可 能减少 主干 线 的无 功 电流
,
,
。
一 般 对 于 均匀 分 布 无
。
,
功 负 荷的配 电线 路 其 补偿 容量 和安 装位 置应 按 【 可
< Β Α !
,
其中
Χ
为 不小 于
7
的整数 ! 规 则求 得 补 偿方案
、 , ,
。
考 虑到 无
,
根据负荷 情况相 应投 人 补 偿 容量
,
。
万元 Α # 月 万 元 二 < 科 %5 万元 5 8 用 % ; 万元 管理费 8 销售费用 % 5 万 元 8 财务费用 7 万元 4 8 一 ; 7 75 刁% 一 7 6 % ≅ % 5 年利 润 销售 收 人 一 其 他各 项# Ο < ∀ 74 万 元 二 7 ; ∃ 万 元 # % ≅ 一 ! 项 目投 资 回 收期 # 年 投 资 收益 率 6 Κ 左 右 4 由 以 上 分析 可 知 项 目的 利 润 可 观 投 资 回 收期 短 投 资 收 益率高
; ∃一 7 ? 5
万元 Μ
8
; Κ
Μ
7
%
5 7
Α
万元
工业 窑 炉 大 气 污 染排放标 准
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
关于五里堠二次电缆统计以下为一套动态无功补偿装置二次电缆统计:电缆管编号电缆或导线方向
ZR KVVP22—450/750 铠装屏蔽电缆规格总长
(m)
何处来何处去
C00——1 ZR KVVP22—450/750
铠装屏蔽电缆1(4×2.5)控制屏1D 35KV进线主变CT
测量
C00——2 ZR KVVP22—450/750
铠装屏蔽电缆1(4×2.5)控制屏1D MCR本地端子箱
CT测量
C00——3 ZR KVVP22—450/750
铠装屏蔽电缆
1(4×4)控制屏2D 直流屏KM线
C00——4 ZR KVVP22—450/750
铠装屏蔽电缆1(4×2.5)控制屏2D MCR本地端子箱
直流端子
C00——5 ZR KVVP22—450/750
铠装屏蔽电缆
1(4×2.5)控制屏2D 交流220V电源
C00——6 ZR KVVP22—450/750
铠装屏蔽电缆
1(4×2.5)控制屏2D 进线35KV测量PT
C00——7 ZR KVVP22—450/750
铠装屏蔽电缆1(4×2.5)控制屏2D 10KV进线母线PT
测量
C00——8 ZR KVVP22—450/750
铠装屏蔽电缆1(6×1.5)控制屏3D MCR本地端子箱
非电量保护信号
C00——9 ZR KVVP22—450/750
铠装屏蔽电缆1(6×1.5)控制屏3D MCR快速励磁柜
励磁触发信号
C00—10 ZR KVVP22—450/750
铠装屏蔽电缆1(4×1.0)控制屏3D MCR快速励磁柜
励磁返回信号
C00—11 ZR KVVP22—450/750
铠装屏蔽电缆1(4×2.5)控制屏3D MCR快速励磁柜
快速励磁控制电源
信号
C00—12 ZR KVVP22—450/750
铠装屏蔽电缆1(4×1.5)控制屏3D MCR端子箱温度
开入信号
C00—13 ZR KVVP22—450/750
铠装屏蔽电缆1(6×1.5)控制屏4D 10KV 磁控开关
断路器分合输出
C00—14 ZR KVVP22—450/750
铠装屏蔽电缆1(6×1.5)控制屏4D 10KV C1电容开
关断路器分合输出
C00—15 ZR KVVP22—450/750
铠装屏蔽电缆1(6×1.5)控制屏4D 10KV C2电容开
关断路器分合输出
C00—16 ZR KVVP22—450/750
铠装屏蔽电缆
1(8×1.5)控制屏5D 公用UK测控信号
C00—17 ZR KVVP22—450/750
铠装屏蔽电缆1(4×1.5)控制屏5D 10KV 磁控断路
器常开触点
C00—18 ZR KVVP22—450/750
铠装屏蔽电缆1(4×1.5)控制屏5D 10KV C1电容
断路器常开触点信
号
C00—19 ZR KVVP22—450/750
铠装屏蔽电缆1(4×1.5)控制屏5D 10KV C2电容断
路器常开触点信号
C00—20 ZR KVVP22—450/750
铠装屏蔽电缆1(4×1.5)控制屏5D MCR电抗器隔离
刀常开触点信号
C00—21 ZR KVVP22—450/750
铠装屏蔽电缆1(4×1.5)控制屏5D C1隔离刀常开触
点信号
C00—22 ZR KVVP22—450/750
铠装屏蔽电缆1(4×1.5)控制屏5D C2隔离刀常开触
点信号
C00—23 ZR KVVP22—450/750
铠装屏蔽电缆1(4×4)交流屏380V
电源
MCR就地端子箱
C00—24 ZR KVVP22—450/750
铠装屏蔽电缆1(4×2.5)MCR就地端
子箱380V电
源
MCR快速励磁柜
380V电源
C00—25 ZR KVVP22—450/750
铠装屏蔽电缆1(4×1.5)MCR端子箱
非电量保护
信号
MCR快速励磁柜
非电量保护信号
C00—26 ZR KVVP22—450/750
铠装屏蔽电缆1(4×1.5)MCR端子箱
过温信号
MCR快速励磁柜
过温信号
C00—27 ZR KVVP22—450/750
铠装屏蔽电缆1(4×.1.5)C1电容器组
放电线圈电
压保护信号
10KV C1断路器
开关柜
电压保护信号
C00—28 ZR KVVP22—450/750
铠装屏蔽电缆1(4×1.5)C2电容器组
放电线圈电
压保护信号
10KV C2断路
器开关柜
电压保护信号
C00——29 ZR KVVP22—450/750
铠装屏蔽电缆1(4X2.5)MCR就地端
子箱380V电
源
MCR本体风机
C00——30 屏蔽通讯线1(2X1.0)快速励磁柜控制屏
C00——31 屏蔽通讯线1(2X1.0)控制屏后台上位机。