Honeywell安防系统配置指南

合集下载

Honeywell 70 75 Series移动计算机配件指南说明书

Honeywell 70 75 Series移动计算机配件指南说明书

Vehicle Dock, CK70/CK71/CK75
871-035-001 (1001AV01)
Vehicle Holder, CK70/ CK71/CK75
805-673-001 (1001AV02)
Retains mobile computer in vehicle environment. Easy one-handed removal of device. Provides USB Host (HDB15M) and RS-232 (DB9M) receptacles. Provides 5V DC on RS-232 Pin 9 for powering peripherals. Requires 805-638-001 Mounting Kit and power option listed below. Optional 850-828-001 Audio Adapter via USB port. Optional USB Host Cable VE0112016. Compatible with Scan Handle or Magnetic Stripe Reader. Not compatible with Snap-On Adapters.
70/75 Series Mobile Computer Accessories Guide |
2
ACCESSORIES GUIDE
PRODUCT NAME Vehicle Dock Mounting Kit
SKU 805-638-001
Power Cable, Dock-to-Fuse Block 226-109-003
Power Option: For connection of Vehicle Dock to forklift power systems operating on 15–96V DC. Provides filtering and conditioning. Includes all power cables and cable mounting hardware.

霍尼韦尔Honeywell报警系统产品方案

霍尼韦尔Honeywell报警系统产品方案

目录1、报警系统方案 (1)1.1系统总体设计 (1)1.2系统功能 (2)1.2.1 紧急报警功能 (2)1.2.2 入侵报警功能 (3)1.2.3 设防、撤防功能 (3)1.2.4 防破坏及故障报警功能 (3)1.2.5 声光报警功能 (3)1.2.6 系统自检功能 (3)1.2.7 报警图像复核功能 (3)1.2.8 电源切换功能 (3)1.3功能实现 (4)1.4设计方案 (4)1.5报警设备选型及参数说明 (5)1.5.1 报警主机VISTA 120 (5)1.5.2 报警管理软件(IP-ALARM/4/10 ) (6)1.5.3 网络接口模块(IP2000) (7)1.5.4 4293SN单防区总线模块........................................................................ 错误!未定义书签。

1.5.5 红外双鉴探测器DT-6360STC (7)1.5.6 串行接口模块(4100SM) ................................................................... 错误!未定义书签。

1.5.7 可变文字英文键盘6160 (8)1、报警系统方案1.1 系统总体设计报警管理系统主要由前端的各种探测器、防区模块、控制主机、控制键盘等设备构成。

报警管理系统主要用于防范对XX的入侵报警,在XX各个不同的需要防御的位置,安装各种不同功能的报警探测装置,根据不同的需要设置壁挂双鉴探测器、吸顶双鉴探测器、红外对射、紧急报警按钮等,通过防盗报警主机的集中管理和操作控制,如布、撤防等,构成立体的安全防护体系。

当系统确认报警信号后,自动发出报警信号,提示相关管理人员及时处理报警信息,并通过与电视监控子系统的联动等功能的实现,达到很高的安防水平。

根据XX的特点,采用报警信号与监控系统进行软联动的方式,构成点面结合的立体综合防护;系统能按时间、区域、部位任意设防或撤防,键盘能实时显示报警部位和有关报警资料并记录,同时按约定启动相应的联动控制,联动本地视频录像存储;系统具有防拆及防破坏功能,能够检测运行状态故障。

霍尼韦尔安防系统

霍尼韦尔安防系统
2.1.2编辑、删除操作员
删除操作员只需要在操作员列表中选中想要删除的操作员的行,单击“删除”即可。更改操作员资料只需在操作员列表中选中该操作员并单击“编辑”就可以对操作员的级别、名称及密码做出修改,填写完成后单击“保存”即可完成对操作员的编辑。单击“关闭”按钮或者是右上角的关闭小图标即可关闭该窗口。
3、卸载完成后,系统提示卸载成功,只要单击“确定”卸载的全过程就结束了。
IP-Alarm系统管理
安装完IP-Alarm软件之后,首先要在IP-Alarm系统管理系统中进行设置。通过“开始——程序——IP-Alarm或者通过双击桌面的“IP-Alarm”快捷方式即可启动。
1登录
在启动软件之后,将会弹出如图的登录界面。为了对操作员的操作进行一定的权限限制,在进入系统时必须进行登陆。在操作员代号中选择已经定义过的操作员,在密码栏中输入相应操作员的密码即可,单击“退出”可以退出软件。这里我们提供了一个默认的系统管理员级别的操作员“ADM”,其密码也为“ADM”。
3.1.1系统属性设置
在设备类型添加完成后,点击“下一步”,在该窗口中主要完成系统资料、接警方式等基本属性的设定。
“基本资料”窗口:在基本资料窗口中,设置“设备编号”、设备名称“、“安装人”、“安装人电话号码”、“安装日期”、“安装位置”和“备注”。
“详细资料”窗口:在详细资料窗口中,用户要根据实际情况选择主设备所拥有的子系统、防区及使用者数量,图中所示为8个子系统、128个防区、10个使用者(均为默认值),并且填写“安装员码”(当需遥控主设备时必须正确的填写安装员码)。
在“基本资料”界面中修改完资料后,单击“修改”,基本资料修改完毕。
单击“详细资料”,进入详细资料修改界面。
在详细资料中修改和基本资料修改步骤一样,改完资料后,单击“修改”,详细资料修改完毕。

霍尼韦尔安防产品基本介绍

霍尼韦尔安防产品基本介绍

从系统中暂时使某个(些)防区失效,以便剩下的防区可以被布防。 布防后被旁路防区允许人在防区内走动,没有被旁路的防区将被布 防。旁路的防区不受保护。
●报警中心(CMS)
当发生报警时用户呼叫求助的地方,报警信号送到报警中心,相应 责任人会做出及时的反应。
●进入延时Entry Delay (键盘蜂鸣音连续提示)
2
霍尼韦尔公司产品优势:
1 安防系统系列化,可以为客户提供一站式服务。 2 防盗报警,电视监控,门禁,消防系统可实现完全集成,无须 二次软件开发。 3 安防系统可以直接集成 Honeywell 楼控设备。
4 良好的品牌保证,质量稳定,技术领先。
5 良好的本地化技术支持和技术研发。
3
一:报警产品的概念和分类
20
室外各种类型探测器图示
AX100/200PLUS
VX-40
BX-80N
LX802N
21
室内各种门磁探测器图示
22
各种类型无线探测器图示
(5890红外、5816窗磁、5882接收机、5804按钮、5808烟感)
23
霍尼韦尔报警探测器 技术发展
●均匀一致的红外透镜 全方位调节一致,避免将老虎看成猫;将猫看成老虎。
36
输出功能:
▪键盘内置蜂鸣器,作为故障、报警等事件提 示 ▪系统及防区状态LED灯指示 ▪内置拨号器,直接报告到报警接收机
通讯协议:
▪ADEMCO 4+2 DTMF ▪CFSK lll ▪4/9ADEMCO DTMF
电气特性:
▪6.5 AH可充电后备电池,12 VDC ▪1 6. 5 VAC,25W~40W变压器
16
DT7000系列K波段微波红外双鉴移动探测器

Honeywell安防系统配置指南

Honeywell安防系统配置指南

门禁控制器 (N-1000-III)
门禁控制器 (N-1000-IV)
门禁控制器 (N-1000-IV)
最多不超过31个,总长不超过1200米
Honeywell安防系统配置指南
门禁控制器的配置-PW2000
门禁电脑 串口 通信转换器
(Winpak Pro)
PW-485-PCI-B
RVVP0.5 x 2
Honeywell安防系统配置指南
Ademco大型报警系统配置指南
被动红外探测器探测范围的界定?
W
L 顶视图
Honeywell安防系统配置指南
侧视图
Ademco大型报警系统配置指南
如何选择探测器? 我们通常所述的探测范围 L x W,就如上图中的描述,如:
DT7225: 7.6x9米 DT7235: 11x11米 DT7450: 15x18米
副控键盘:
AVBPCKND:无显示 AVBPCK:无操纵杆 AVBPCKZ:内置操纵杆 AVBPCKC:内置操纵杆、16功能键 AVBPCKA :内置操纵杆、16功能键、喇叭

需要控制球机吗?
PIT422

需要Vista-120连动吗?
PIT232/232
Honeywell安防系统配置指南
摄像机配置指南—固定球机

4297延伸器

之所最
和有多
4297延伸器
不4并 超接 过2 8
1
1 9个
274
2
0
前 面
2
0 多
0距9 米离 7


线
4297延伸器
4297后面距离前所述不超过1200米
Honeywell安防系统配置指南

霍尼韦尔安防监控系统方案资料

霍尼韦尔安防监控系统方案资料

霍尼韦尔健康舒适家居安防监控系统钻石山设计方案工程编号:20150331二零一五年三月霍尼韦尔家居系统优点1、提供符合每位客户需求的定制解决方案2、根据多年来的家居系统的经验和技术发展,提供可靠的解决方案3、同一品牌的家居系统集成确保质量可靠、服务周到霍尼韦尔家居系统的价值观智能由于先进信息技术的广泛应用,霍尼韦尔的客户享受着更高标准的生活方式。

安全霍尼韦尔为您提供了最全面防范的安全体系,如高科技集成防盗和防火系统,门禁系统等。

舒适霍尼韦尔通过使用其全球顶尖的自动化控制技术,在水处理、空气质量、温度、湿度、安防、燃气安全、灯光和家居智能等方面,为您提供全面舒适的居住环境.一、家庭安防监控系统简介:近年来,随着我国经济的迅速发展,城乡居民的生活水平有了显著的提高,尤其是城镇居民的居住条件不断改善,人们在解决了居住问题后,日益关心的是居住是否安全,人们在购房时,安全性是考察物业管理水平是否完善的一个重要条件。

尤其是那些流窜作案的犯罪分子,往往选择居民小区作为攻击目标,入室盗窃、抢劫、杀人案件屡屡发生,以往靠小区报安以人防为主的防范措施已满足不了人们的要求。

利用安全防范技术进行安全防范首先对犯罪分子有种威慑作用,使其不敢轻易作案。

如小区的安防系统、门窗的开关报警器能及时发现犯罪分子的作案时间和地点,使其不敢轻易动手.家庭安防应有两重含义,一是指生命安全,二是指财产安全.传统家庭安防是安装被动红外探测器,其特点是安装在室内,因此对室内无人值守时,其防盗保护财产的作用能够实现。

而新型智能家庭防盗报警系统在感应端通过磁头、红外、煤气、烟感、玻璃破碎等探测器来感应异常变化,当感应器感应到异常情况,就会自动报警并把警情发送至相关部门和人员的电话上,以便得到及时的处理,减少人员伤亡和财产损失.目前,家庭监控的业务模式是IP摄像机+各类报警探测设备+平台接入。

在这样的模式下,用户离开时布防,发生意外情况时触发报警,报警信息以短信形式及时发送给用户,同时启动警铃并联动IP摄像机进行预置位转动、抓拍图片、启动录像等程序.用户收到短信后通过PC 或手机登录并实时浏览现场视频,确认后采取处置措施,用户回来后撤防.而对于家庭安防系统的建立,现阶段还需要专业队伍的安装和服务。

霍尼韦尔 Honeywell安防系统编程指南

霍尼韦尔 Honeywell安防系统编程指南

附录:LYNXRIEN-CH 连接图摘要 ................................................................................................ 28
i
Honeywell
1 前言
1.1 适用范围
感谢您使用 ADEMCO LYNXRIEN-CH 安防系统。 本书介绍 ADEMCO LYNXRIEN-CH 安防系统的编程方法,能帮助您快速了解并学会使用该产 品。
*29
夏令时开始/结束月份
*30
夏令时开始/结束星期 输入一个月适当的开始和结束星 期。
பைடு நூலகம்
[0,0] 开始 结束 0=禁用; 1=第一个周末 t; 2=第二个周末; 3=第三个周末; 4=第四个周末;5=上一个周末; 6=上上个周末; 7=倒数第三
4
Honeywell
个周末 防区报警与计时 ( *31– *39) *31 每个防区一次报警声 此字段只适用于防盗防区(防区响 应类型 1-5、10),并且影响长距 离无线电装置报告,但不影响接警 中心报告。 注:此字段只适用于闹铃,但不影 响键盘声音 火灾轰鸣器暂停 本控制器符合 NFPA 关于火灾通 知设备的间歇式脉冲警报声的要 求。火警间歇式脉冲警报声的组成 如下所示:3 次脉冲 - 暂停 - 3 次 脉冲 - 暂停 - 3 次脉冲... 警报时间 此字段确定外接轰鸣音在规定的时 间后是关闭还是持续响起直到手动 关闭。 退出延时 如果在系统布防后打开了退出门, 系统将等待输入的时间结束后才响 起警报。 进入延时01 如果系统没有撤防,在进入时系统 将等待输入的时间结束后报警。 进入延时02 在进入时系统将等待输入的时间结 束后才报警。 有声退出警告/快速退出 退出警告:声音由缓慢的连续提示 音以及最后 5 秒的快速提示音组 成。警告声将在退出延时终止时结 束。 布防确认音 布防确认是在发送关闭报告后或在 退出延时结束时外部轰鸣器发出的 0.5 秒“叮当”声。 如果选择了选项 2,则外部轰鸣器 在系统收到 RF 发射后立即发出 “叮当”声。 开机状态 当系统以布防状态开机时,如果防 区出现故障,系统将在布防后响起

霍尼韦尔防盗报警系统方案.docx

霍尼韦尔防盗报警系统方案.docx

防盗报警系统设计方案'防盗报警系统的组成防盗报警系统由现场探测器、现场控制器及监控中心三部分组成。

一个完整的防盗报警系统如下图所示:图1防盗报警结构示意图现场探测器现场探测器(传感器)主要有红外/微波双鉴探测器、红外对射探测器、门磁开关、玻璃破碎探测器等。

此外,为了防止发生抢劫事件以及在发生紧急情况时报警,在有需要的地方安装紧急按钮和脚挑开关等。

随着用户对防盗要求的进一步提高,单纯的室内报警已经不能满足要求,用户迫切希望能有一套将盗贼拒之于门外的防盗系统,因此,周界防范系统应运而生。

现场控制器现场控制器或防盗控制主机是带微处理器的控制器,当它接收到现场的报警信号时,一方面对现场报警点进行操作和控制,另一方面向监控中心传送有关的报警信息,在监控中心的显示屏上显示出来或在监控中心的打印机上把有关的报警信息打印记录下来。

现场控制器的主要功能有:接收带地址的报警信号有不同性质的防区,通过编程确定防区的性质可带控制键盘和液晶显示器,控制布防和撤防,有密码操作功能输出信号带动报警器和输出标准信号推动联动的设备与监控中心的通信功能③监控中心监控中心由高档微机(多媒体)、高分辨率的大型彩色显示屏、中英文打印机(可选卜不间断电源(UPS)以及与现场控制器的通信联接器组成。

此外,应有密码操作功能、图形功能、报警处理、报警、报表打印、资料处理以及与CCTV系统有联动功能的软件支持。

监控中心的主要功能是接受现场报警、显示及打印报警信息,显示报警现场平面图形,报警点有明显的闪烁。

对于与CCTV系统有联动功能的报警点输出信息到CCTV系统。

监控中心的另外一个主要功能是控制现场报警点的布防和撤防,或每天按时间程序进行布防和撤防。

】、防盗报警系统的设计原则通常,在大厦内部的主要设施和要害部门都要求设置防盗报警的装置,这些场所包括停车场、办公室、会议厅、会展厅、秘书室、保密室及其公共部分,中心周围及主要场所的出入口等。

防盗报警系统的设计应当从实际需要出发,尽可能地使系统的结构简单、质量可靠、操作方便,设计时应遵循的基本原则如下:系统必须可靠,具有自动防止故障的特性,这意味着即使工作电源发生故障,系统也必须处于后备电源供电的工作状态。

霍尼韦尔安防系统产品及解决方案介绍

霍尼韦尔安防系统产品及解决方案介绍

Pro-Watch PE Vs CE
PWPE 支持的操作系统
WinXP Prof., Win2000 Prof., Win2000 Server, Win2003 Server MSDE (包含, 自动安装) 2G 不支持
PWCE
Win2000 Server, Win2003 Server
数据库 最大的数据库容量 支持企业数据库同 步功能
- 2个工作站操作员用户许可证 - 1个发卡工作站操作员用户许可证 - 96个读卡器许可证
• 无限制的扩容
- 可以按照32/64/128/256或者其倍数增加读卡器数量 - 可以按照1/5/10/15/20倍数增加操作员用户数量 - 增加制卡操作员用户数量
22
HONEYWELL - CONFIDENTIAL
PW-2000-IV
PW-2000-IV
Up to 64 Readers Per Panel CCTV System
5
HONEYWELL - CONFIDENTIAL
HVS-HL-SK-05082005
PW6000通讯方式
•Ethernet网络连接 (TCP/IP) •RS-485 •RS-232 •Modem 拨号连接
6
HONEYWELL - CONFIDENTIAL
HVS-HL-SK-05082005
PW-6000 – 智能控制器 •PW-6000智能控制器 - 闪存技术 - 真32位微处理器(Moto MC68340 处理器) - 支持多种格式读卡器和卡类型 •PW6000 独有特性 - 双通信路由机制 - 最多支持32个输入/输出/读卡器模块 •PW-6000 主控器模块 - 每个读卡器8种读卡格式 - 操作模式: 闭锁/开锁, 读卡, 密码, 卡和密码, 卡或密

霍尼韦尔 Honeywell安防系统快速指南

霍尼韦尔 Honeywell安防系统快速指南

PREK5966CH 4/07 Rev. AADEMCO LYNXRIEN-CH安防系统快速指南 概述本快速指南通过使用默认安装设置,提供安装的基本操作步骤,可以帮助您简单快捷地安装可充电LYNXRIEN-CH。

需要更多详细信息和重要提示,请参考LYNXRIEN-CH安装指南。

安装LYNXRIEN-CH安装和电路连接步骤动作1. 如下安装控制器:a. 从底板上分离出前面板,并从前面板上拔下电缆提示:切勿从电路板上的对外连接器上拔下带式电缆,只能从主机前面板拔下电缆。

b. 安装后盖.2. 按如下步骤进行线路连接:a. 将拨入电话线连接到8位置插孔或端子2(TIP)和3(RING)。

b. 将手提电话线连接到RJ11插孔或端子4(TIP)和5(RING)。

提示:对于完全线路抢占,请查阅安装说明c. 如果使用,请将压电轰鸣器连接到端子10(+)和11(-)d. 如果使用,请将闹铃连接到端子11 (–)和12 (+).e. 将交流变压器的导线连接到端子15和16.3. 按如下步骤连接电源:a. 取下电池固定器。

b. 从底板上的胶带上撕下陈片。

c. 将电池组插入底板。

d. 安装电池固定器。

e. 将电池接头插入接线印刷电路板上的插座。

f. 小心地将带状电缆重新连接到主机前面板接头上(正确对准红线)。

g. 所有线路连接完毕后,将主机前面板卡入底板,使其被卡扣固定。

h. 将变压器插入一个 24 小时 220V交流无开关插座。

注: 充电式电池组需要 48 小时来充足电。

在四小时内或进入测试模式时,“电池低电压”信息会消失。

LYNXRIEN-CH 线路连接系统编程步骤动作1. 按如下步骤设置编程默认值:a. 进入编程模式: 安装人员代码 + 8 0 0。

b. 按*97,然后按1-4中一位数字,从LYNXRIEN-CH 设置默认值表中选择默认值。

2. 按如下步骤设置可变数据字段:a. RF 住宅ID代码 – 按 *24, 然后输入无线键盘需要的两位RF住宅ID。

霍尼韦尔安防产品系统介绍

霍尼韦尔安防产品系统介绍

5
霍尼韦尔 - CONFIDENTIAL
File Number
微波探测原理
• 微波探测原理-多普勒效应
相近运动频率变 高
背离运动频率变 低
原始微波频 率
相近运 动
背离运 动
6
霍尼韦尔 - CONFIDENTIAL
File Number
前端探测器-移动探测器
• K-波段双技术移动探测器
- DT-7235T - DT-7435 - DT-7450 - DT-7550C
33
霍尼韦尔 - CONFIDENTIAL
File Number
霍尼韦尔报警控制主机——Vista-120
• Vista-120的门禁功能
- 通道(门)
Vista-120总线
2
- 锁控制(输出端)
- 外出控制(读卡器/出门按钮)
- 门状态监视(门磁)
- 主控制器(VistaKey)
- 输入端总数=2
24
霍尼韦尔 - CONFIDENTIAL
File Number
霍尼韦尔安防报警中心系统
全球使用最多的报警中心系统
25
霍尼韦尔 - CONFIDENTIAL
File Number
霍尼韦尔安防685 数字报警中心接收机
26
霍尼韦尔 - CONFIDENTIAL
File Number
系统结构
电话线
16
霍尼韦尔 - CONFIDENTIAL
File Number
前端探测器-移动探测器
• DT7435
- *探测范围:11 X 11 M
- *能抵御较大动物引起的误报 - *加电/定时自检保证探测器正常工作 - *双处理核加快处理速度,同时比对多组数据 - 保证探测器可靠性

霍尼韦尔 安防2316 Plus控制主机

霍尼韦尔 安防2316 Plus控制主机

2316 Plus控制主机安装手册目录手册使用说明 (3)家居配置 (3)安装 (3)控制主机接线 (4)系统加电 (5)键盘启动 (6)编程选项 (7)主机编程 (7)对液晶键盘编程 (8)安装员须知 (24)重要通知 (24)测试 (24)看门狗指示灯 (24)电话线路问题 (24)键盘操作指令集 (25)常见问题解答 (26)减少误报注意事项 (28)注释 (29)报警系统的局限性 (32)2316 Plus控制主机编程表格 (33)2316Plus控制主机安装手册键盘操作指令集LED键盘和ALPHA II键盘的大部分指令功能是相同的,只有少数的指令是ALPHA II键盘专用的。

下面的指令适用于LED及ALPHA II两种键盘:功能 注释按键布/撤防有延时[密码] [#]旁路防区 (n)[n] 是防区号码 # 1 - 16; 可能需要密码 [密码] [旁路] [n] [#]门铃开/关可能需要密码[密码] [*] [5] [#]用主码修改密码必须从用户1开始[主密码] [*] [0] [#] [用户号码][新密码] [#] [新密码] [#]清除报警记忆[*] [1] [#]退出编程[*] [#]火警键盘启动[F] (按住 3 秒)组旁路或布防布防系统,CL 30 - 3F, 数据位 3设定的组旁路防区都被旁路。

可能需要密码(留守布防) [密码] [*] [4] [#]组旁路或即时布防同上,但系统即时布防。

可能需要密 [密码] [*] [4] [7] [#] 或者码(即时留守布防)[密码] [*] [7] [4] [#]即时布防布防系统,延时防区转换成即时防区 [密码] [*] [7] [#](有外出延时,无进入延时), 可能需要密码键盘启动遥控编程若CL 0B(3)中使能; 可能需要密码 [密码] [*] [0] [2] [#]紧急救助键盘启动 [E] (按住 3 秒)紧急报警键盘启动 [P] (按住 3 秒)辅助电源复位复位设备接在5、6端子 [*] [6] [2] [#]主机复位 [Master 密码] [*] [6] [8] [#]电池测试电池电压低恢复以后用 [*] [6] [4] [#]警号测试可能需要密码 [密码] [*] [6] [3] [#]报警中心测试可能需要密码 [密码] [*] [6] [1] [#]步测 [*] [6] [0] [#]以下指令仅对 ALPHA II键盘有效:功能 注释 按键布防音开关[*] [5] [4] [#]布防确认音开关[*] [5] [1] [#]背景光开关[*] [8] [#]显示键盘型号、版本[*] [9] [#]门铃开关[*] [5] [3] [#]预警开关[*] [5] [2] [#]以下所列为只适用于安装员的键盘指令:功能 注释 按键ALPHA键盘编程开始对键盘进行编程[安装员密码] [*] [0] [1] [#]ALPHA键盘测试[*] [6] [7] [#]主机复位[安装员密码] [*] [6] [9] [#]主机编程开始对控制主机进行编程[安装员密码] [*] [0] [#]2316Plus控制主机安装手册减少误报注意事项本章节的内容可以帮助您来减少系统误报,第一栏是编程指令地址和数据位,第二栏是建议编程值和简单描述:编程项指令地址、数据位功能描述布防/密码09 (2) 密码 可以防止未经授权用户操作键盘,象布撤防、旁路、启动遥控编程等都需要密码。

霍尼韦尔安防产品系统介绍

霍尼韦尔安防产品系统介绍

Vista-120总线
2
Vistake y
1
2
34
霍尼韦尔 - CONFIDENTIAL
File Number
霍尼韦尔报警控制主机——Vista-120
• 外围接口 - 电话线和报警中心以及遥控编程软件连接 - RS232串口连接计算机,报告警情 - TCP/IP局域网连接,报告警情,控制主机
35
16
霍尼韦尔 - CONFIDENTIAL
File Number
前端探测器-移动探测器
• DT7435 - *探测范围:11 X 11 M
- *能抵御较大动物引起的误报 - *加电/定时自检保证探测器正常工作 - *双处理核加快处理速度,同时比对多组数据 - 保证探测器可靠性
• DT7450
- 探测范围:15 X 18 M - 灵敏度一致的光学统 - 自适应微波系统 - 下望窗 - 双处理核
霍尼韦尔 - CONFIDENTIAL
File Number
报警系统典型案例介绍(典型的错误配置)
紧急按钮
1# 8# 1#
脚挑开关
20#
玻璃破碎 探测器
1# 8#
被动红外 探测器
1# 50#
微波/红外 双鉴探测器
1# 30# 1#
震动探测器
8#
门磁探测器
1# 20 #
总线编码器(1/2/8防区总线编码器4293SN/4193SN/4208U)
分 控 键 盘
分 控 键 盘
分 控 键 盘
分 控 键 盘
分 控 键 盘
37
霍尼韦尔 - CONFIபைடு நூலகம்ENTIAL
File Number
基于TCP/IP网络的系统优势

霍尼韦尔Honeywell安防系统安装和设置指南

霍尼韦尔Honeywell安防系统安装和设置指南

霍尼韦尔Honeywell安防系统安装和设置指南霍尼韦尔(Honeywell)是全球领先的安防系统供应商之一,他们提供一系列的安全产品和解决方案,包括监控摄像头、入侵报警系统、无线安防系统等。

在本指南中,我们将为您介绍如何安装和设置霍尼韦尔安防系统。

1.选购合适的产品在安装和设置之前,您需要根据您的需求选择合适的霍尼韦尔安防产品。

您可以根据需要选择监控摄像头的数量和类型,入侵报警系统的传感器,以及无线安防系统的探测器等。

2.确定监控区域和安装位置在安装摄像头之前,您需要确定监控的区域和最佳安装位置。

根据您的需求,您可以选择将摄像头安装在室内或室外,并确保摄像头能够覆盖您想要监控的区域。

3.安装摄像头按照供应商提供的安装指南和说明书,将摄像头安装在您选择的位置上。

确保摄像头的固定牢固,并且摄像头的视野没有任何遮挡物,以确保最佳的监控效果。

4.连接摄像头和监控系统将摄像头与监控系统连接。

根据型号的不同,摄像头可以通过有线或无线的方式连接到监控系统。

对于有线连接,您需要将摄像头与监控系统的主控器使用电缆进行连接。

对于无线连接,您需要按照说明书中的指引进行无线连接。

5.设置监控系统一旦摄像头与监控系统成功连接,您可以开始设置监控系统。

首先,您需要确保监控系统的电源和网络连接正常。

然后,根据监控系统的操作指南,您可以设置摄像头的各种参数,比如分辨率、画面质量、录像时间等。

6.安装入侵报警系统对于入侵报警系统,您需要选择一个或多个传感器,将其安装在需要监控的区域。

传感器可以是门窗磁感应器、红外线传感器或玻璃破碎传感器等。

按照供应商提供的指南,将传感器安装在合适的位置上,并将其连接到报警主机。

7.设置入侵报警系统一旦传感器安装完毕,您可以开始设置入侵报警系统。

根据供应商提供的指南,您可以设置传感器的触发条件和报警方式。

您可以选择将报警信息发送到手机或电子邮件等方式,并根据需要设置报警延迟时间和报警停止条件。

8.安装无线安防系统对于无线安防系统,您需要选择一个或多个探测器,将其安装在需要监控的区域。

霍尼韦尔安防方案

霍尼韦尔安防方案

VISTA-l20是一款先进的多功能控制主机,它可分为8个子系统,同时使用常规四线,总线和无线防区(总共128个防区),还可通过可编程继电器控制电器或联动CCTV,并可通过电话遥控主机和控制继电器。

防区特性:•9个基本防区,3个键盘紧急按键防区,还有胁持防区•防区9可设置响应时间为1 0毫秒或350毫秒•可通过无线或总线方式,将防区扩展到1 28个控制特性:•可以划分为8个独立子系统及3个公共子系统,可当作8台独立主机使用•可选择使用4 1 46布/撤防开关锁或无线按钮控制•支持4286模块通过电话监控主机•224/1000条事件记录,可通过遥控编程下载或直接从键盘上查看•支持150/250个分为7个级别的用户密码•可设置出入及周边防区门铃警示•留守及快速布防时自动旁路内部失效防区输出特性:•内置拨号器,报警时自动拨号报告•RS-232•TCP/IP通讯协议:•ADEMCO 3+1/4+1/4+2•ADEMCO 4+2 Express•ADEMC0 CONTACT I D•RADIONlCS/SESCOA 3+1/4+1/4+2电气特性:•7AH可充电后备电池,12VDC• 1 6. 5 VAC,25VA变压器输出:•警号电流:2Amps,12 VDC•750mA辅助电流,12VDC•最大支持96路继电器输出遥控编程:•使用COMPASS(wlNDOWS版)软件对主机进行遥控编程门禁控制:•主机内置有键盘控制门禁功能,新版本主机直接支持8/15个Vista—Key感应卡读卡器门禁模块先进时序:•实时时钟控制应用场合•机场、医院、博物馆、大中院校、大型百货公司、写字楼、政府机关、监狱等大型集中监控场所DT6360STC智能型吸顶式双鉴探测器•红外/微波双技术•特制赋形天线提高灵敏度,降低误报•内置微处理器•微波探测范围可调•双元PlR元件•1NFORMER(比例监控电路)•全功能自诊断•外壳及天花板防拆开关•自动温度补偿•抗辐射干扰•嵌入式安装,美观大方•附件:DT一6360STC卧式安装组件,PlR遮光材料特性:•探测范围:15 m(直径)•电源要求:40mA/12 VDC,10~12.9 VDC•灵敏度:探测范围内正常步速2~4步•微波频率:10.525GHz•防拆: (NC)25 mA,30 VDC•报警继电器:C型继电器,125mA,25 VDC•工作温度:0℃~49℃,5%~95%相对湿度(无冷凝) •抗辐射干扰:30 v/m,10MHz~1000MHz•可选安装高度范围:2 4m~4 8 m•尺寸:127 x 127 x 58 mm•认证:UL,FCC,CCC•重量:397 g应用场合•无法墙装在对面是玻璃幕墙或中间有遮挡(如图书馆、货架等)的场合,嵌入式安装更加美观、隐蔽DT7225 K-波段双鉴探测器•具有极佳的防误报及捕获能力•安装简单快捷•内置温度补偿及微波抗干扰功能•K-波段微波探测技术及特别赋形天线进一步抑制误报,提高探测器的灵敏度•ABS外壳坚固耐用,防震功能极佳特性:•探测范围:7.6×9 m•电源要求:25mA/7.5~16 VDC (UL: 8.9~14.5 VDC)•灵敏度:探测范围内正常步速2~4步•微波频率:24.125 GHz•防拆: (NC) 50 mA,24 VDC•报警继电器:A型继电器,500mA,30 VDC•工作温度:-25℃~65℃,5%~95%相对湿度(无冷凝)•抗辐射干扰:30 v/m,10MHz~1000MHz•抗白光干扰:8000 Lux•尺寸:119×71×42 mm•认证:UL,ULC,lC,FCC,CE,CCC•附件(安装支架):SMB-10,SMB-10C•探测范围与DT725A一样应用场合•防误报性能好,对于仓库、密室等温度异常的特殊场合误报免疫性高,当然也适用于普通场合。

英国Honeywell生产的智能上锁管理系统说明书

英国Honeywell生产的智能上锁管理系统说明书

Installation12-24V AC/DC:Connect 12 or 24V (AC or DC, 50 or 60Hz) to these two terminals to provide the powernecessary to operate the keypad. For most installations, the keypad and electric lock will share thesame power supply.Output 1: Electric locking device control relay (3 terminals). Connect the positive (+) lead from thepower supply that is being used to power the locking device to the (COM)terminal. If the locking deviceis a Fail Safe (power to lock) type, connect the positive lead of the locking device to the NormallyClosed (N.C.)terminal. If the locking device is a Fail Secure (power to unlock) type, connect thepositive lead of the locking device to the Normally Open (N.O.)terminal. Connect the negative wire ofthe locking device to the negative (-) lead of the power supply that is being used to power the lockingdeviceEG.: This terminal is for connection to an Request-To-Exit Egress device. Connect one lead from theegress button to the EG terminal, and the other lead to the negative power supply output that ispowering the keypad. The egress device must provide a N/O momentary contact. Multiple devices canbe wired in parallel.T amper N.C.: These terminals are not used.Inductive Kickback Protection: Inductive Kickback is a strong electric pulse (up to 500v) generatedby electric locks when power is removed. It is strong enough to destroy the relay contacts in the 917keypad, unless a protective device is added to the circuit. Included with the 917 keypad is a diode thatcan provide this protection for DC-powered electric locks (except magnetic locks). For magnetic locksand all AC-powered locks, use an MOV instead. Wire it into the circuit as seen in the diagram to theleft, taking note of the polarity for the diode (identified by the silver band) and locating it as close aspossible to the electric lock.Featuresprotect against inductivekickback.SECURITY DOOR CONTROLS3580 Willow Lane, Westlake Village, CA 91361-4921 • (805) 494-0622 • Fax: (805) 494-8861•E-mail:***********************P:\INSTALLATION INST\ACCESS CONTRLS\INST-917 Stand Alone.vsd Rev G 03-10 Page 1INSTALLATION INSTRUCTIONS917 EntryCheck Stand-Alone KeypadTMThe SDC 917 Entrycheck Standalone Keypad is designed to control electric locking devices such aselectric door strike, magnetic locks or electrified locksets.Up to 99 different user codes may be programmed into the 917, making it possible to allow or denyentry to any one user, without affecting the codes used by the other 98.Choice of latching or timed output;Timed output:When an authorized PIN code is entered, the relay is activated, unlocking the door perprogrammed time from 1 to 999 seconds. A momentary dry contact connected to the (EG) Request-to-Exit input activates the timed output. PIN codes will not activate the latching function when the keypadis programmed for timed operation.Latching Output:Entering an authorized PIN codes latches the relay output ON or OFF.A momentary dry contact connected to the (EG) Request-to-Exit input will also activate the latchingoutput. The lock is maintained in the ON or OFF mode until a PIN code is re-entered or (EG)Request-to-Exit input is actuated. PIN codes will not activate timed output when the keypad isprogrammed for latching operation.Request-To-Exit Input:A Request-to-Exit device with a momentary, N/O dry contact can be used fortimed egress operation without entering an access code. The device may be an Exit Switch, Sense Baror Request-to-Exit PIR sensor and is typically located within the secured area. When latching operationis chosen, a maintained or momentary, N/O dry contact switching device located remotely or adjacent tothe door may be used for ON/OFF latching without entering an access code.Installation ExamplesThe examples below represent common installation methods.This example uses a single 12VDC power supply to power both the 917 keypad and a 12VDC Fail Secure electric door strike. The N.O. output terminal is used to connect a fail secure device such as a fail secure electric strike.Example #1This example uses separate power supplies for the 917 keypad and two electric locks. This is the preferred method when there are multiple locks being controlled, to help protect the keypad from increased inductive kickback surges caused by the multiple locks.Example #3This example uses a single 24VDC power supply to power both the 917 keypad and a 24VDC Fail Safe magnetic lock. The N.C. output terminal is used to connect this device. Connection of a N.O. egress device is also included in the circuit.Example #2input120VAC input120VAC inputCode Compliant Fixed Time Egress of Entrance Egress Doors. For KeypadsProgrammed for Timed Entry or On/Off Latching:The two following devices are requiredto comply with National, State andLocal Code Criteria per Code Section Titled “Access Controlled EgressDoors” Both device contacts are wired in series with the failsafe lock powerinput. Loss of power to either egress device unlocks door.SDC 423MU or 413MNU Failsafe exit switch with fixed 30 sec. timerSDC 42MD-31DW Failsafe PIR sensor.ASSOCIATED PRODUCTS – TIMED EGRESS CONTROLS Adj. timed Egress for ON/OFF latching Keypads:Wire contacts in series with lock power.SDC MSB55V-10TD or PSB560V-10TD Egress Bars with timer moduleSDC 423U or 413NU Exit Switch withadjustable timer.SDC 2MD-31D-W Timed PIR ExitSensor with adjustable timer .SDC 10TD Mini Timer Module for REXdevices without timers.Adj. Timed Egress for TimedEntry Keypads:Keypads programmed for timed entry,connect to (EG) REX input.SDC MD-31D-W PIR Exit SensorSDC MSB55V or PSB560V Egress Bar SDC 423U or 413NU Exit Switches.inputElectric Strike12VDCFor Keypads Programmed for ON/OFF Latching:Connect momentary contacts to (EG) REX input Pulse on, Pulse off.SDC 423MU or 413NU Exit Switches.For Keypads Programmed for ON/OFF Latching or Timed Entry:Wire contacts in series with lock power.SDC 491or 492Blue Emergency Release Stations.SDC 14-2or 492 7 Day Timer, Scheduled Daily Locking/UnlockingAccess Control Power Supplies1 Amp Class2 Power Supply/Chargers621PJ Power Supply, with Enclosure and Plug-In Transformer.621J Power Supply, with Enclosure, less Transformer.602RF UL 294, Power Supply, 12"x12"x4" Cabinet, built-in Transformer.ASSOCIATED PRODUCTS – REMOTE ON/OFF CONTROLProgrammingAll program settings are protected by a Master Code, to prevent unauthorized changes.When setting up the 917 keypad for the first time (or if the Master Code has been lost) the first step is to program the Master Code you’d like to use.Master Code, Initial Setup:1) Disconnect power from the keypad.2) Set the DAP jumper to “ON”3) Connect power to the keypad. The keypad should start beeping continuously, and the yellow LED flashing continuously.4) Move the DAP jumper to “OFF”. The keypad should stop beeping, and the yellow LED lit steady.5) Enter: 0 MMMM # into the keypad, where “MMMM” is the four-digit Master Code you’d like to use.Example: 0 1234 # would set the Master Code to “1234”Other Programming:Note: All of the programming examples use a Master Code of “1234” but that’s not advisable in actual practice, because it’s too easy for unauthorized personnel to guess.Programming Pattern:As you can see, all programming entries follow the same pattern:[Master Code ] + [number ] + [information to enter, if any ] + [# ][Master Code ] sets the keypad into programming mode. Programming mode is identified by the keypad’s yellow LED being lit steady.[Number ] tells the keypad which feature to change. 0=Master Code; 1=User Code; etc.[# ] completes the programming sequence.User OperationThe yellow LED will flash to indicate that the 917 is ready to accept a command.To release the lock, simply enter one of the User Codes programmed into the keypad, followed by the pound symbol (#):UUUU #Where “UUUU” is a 4-8 digit User CodeExample : if a valid User Code were “7890”, then entering “7890#” would activate the relay to release the lock. The green LED is lit while the relay is activated.If an invalid code is entered , the keypad will return 5 beeps and 5 flashes of the yellow LED. After 10 invalid codes have been entered, the keypad will not allow any more entries for 30 seconds.SpecificationsKeypad Power Requirements:Voltage:12 or 24 volts, DC or AC (50/60hz).Amperage:Standby: 10mA @ 12/24VdcDuring key press: < 30mA @ 12/24VdcDuring relay activation: < 80mA @ 12/24VdcOutput 1: SPDT RelayRelay Contact Rating: (Output 1) 5A@ 28Vdc (Resistive) Factory Default Settings:Master Code: 0000Relay Time: 1 secondUser Codes: None --All are cleared.Access Code WorksheetMaster Code: ____ ____ ____ ____User Codes:120VAC inputThis example uses two 917 keypads to operate the same electric locking device. 917 #1 is considered the master unit and should be located within in the secured area. 917 #2 is the considered a remote egress device and is connected remote egress device terminal (EG) of the master unit.When programming 917 #2, set the Relay Time (programming option 40) to 1 second. Use the Set Relay Time (programming option 40) on 917 #1 to set the unlock time when accessed by either keypad. The latching function (programming option 41) is only available at the master keypad.Example #4Keypad #1 (Master)Keypad #2 (Remote)Keypad #1 Keypad #2 This example uses two 917 keypads to operate the same electric locking device. Power for the electric locking device is wired through both keypads.All programming functions of each keypad are independent from each other. Set Relay Time (programming option 40) must be set on each keypad. The latching function (programming option 41) is available at both keypads.Example #5。

霍尼韦尔HUS安防系统技术方案模版

霍尼韦尔HUS安防系统技术方案模版

HUS系统项目安防管理系统技术方案目录一、系统概述二、设计依据三、设计原则四、安防集成管理系统选型及优势五、总体设计一、系统概述1.1、行业背景分析近年来,随着科技的进步和经济的发展带来了整个社会生活水平的提高,人们生活不再仅仅局限于传统的衣、食、住、行,对周围的居住环境及工作环境安全越来越重视,安全技术防范作为保护人民生命和财产的重要工具也越来越被广大消费者所重视。

在大厦、银行、博物馆、政府机构、商店(超市)、居民社区、企事业单位、工厂、教育、能源等各个领域已经得到广泛应用。

闭路电视监控系统作为安全防范系统最基本、最重要的子系统,得到了最为广泛的应用。

采用闭路监控为主的多种技术防范结合的系统是预防和制止犯罪最为有效的措施、同时也可以通过视频监控系统对各个现场环境的把握,掌控运行状态,提升各个环节的运作效率。

同时在进行视频监控的同时在各个重点出入口和区域建设报警系统,采用现代通信技术和计算机技术以及软件开发技术完成报警系统和视频监控的有效联动。

高清网络视频监控系统由总控中心里的专用显示器、录像设备以及布置在大厦各主要部位的高清摄像机、云台通过专用视频网络组成。

由摄像机将监控视频信息实时传输到监控中心,值班人员可对多路视频图像进行实时的任意的监看,二十四小时实时录像.闭路电视监控作为一项先进的高科技防范手段,特别是由于系统本身具有直观、实时、记录、回放等特点,在许多领域得到越来越广泛的应用。

闭路监控系统主要负责智能大厦外围安全防范,监控车辆/人员出入,对外来作案分子具有威慑作用,是智能大厦安全防范的第二道防线,也是智能大厦安全防范的重要组成部分。

1。

2、技术背景分析随着市场需求的不断变化和网络技术的飞速发展,无论是远程还是本地的中大型监控系统都需要一套完全整合的解决方案。

无论是传统的模拟方式还是现阶段的DVR、DVS单机解决方案都不能很好的解决中大型监控系统的问题,如机场监控,大型小区,智能大楼,学校,连锁网吧,超市,监狱,还有一些诸如边防,基站监控等远程应用。

HONEYWELL报警系统方案

HONEYWELL报警系统方案

HONEYWELL报警系统方案上海使状电子工程设备有限公司二零零七年十月前言当前,随着经济的发展,人民的生活日益改善,人们对家庭生命财产安全越来越重视,采取了许多措施来保护家庭的安全。

以往的做法是安装防盗门、防盗网,但也存在有碍美观,不符合防火要求,不能有效地防止坏人的入侵等缺点。

现在,全国各地都在如火如荼地开展建设安全文明小区的活动,而且很多地方都提出取消防盗网的口号,家庭电子防盗报警系统也就应运而生。

因为大多数家庭都是双职工,白天家里通常没有人,发生报警后,必须要有专人来处理,因此必须设立报警中心。

而且因为国内住宅区大多数是密集型分布,一个住宅区往往有几百上千户,并且都有自身的保安队伍,因此当用户防盗报警系统报警时,除了在现场报警外,还需要向当地派出所或公安分局进行联网报警处理,也需要向住宅小区的保安中心进行联网报警,以便警情得到迅速处理。

另外,考虑到国内普遍收入水平较低,对于每一户家庭的防盗报警系统成本不可太高,但因为用户数量多,也不能采用质量差的产品,以免误报频繁造成不良影响。

根据以上分析,本案具有以下特点:⑴广泛性——要求小区内每个家庭都能得到保护。

⑵实用性——要求每个家庭的防范系统能在实际可能发生受侵害的情况下及时报警。

并要求操作简便,环节少,易学。

⑶系统性——要求每个家庭的防范系统在案情发生时,除能自身报警外,必须及时传到保卫部门,并同时上报当地公安报警中心。

⑷可靠性——要求系统所设计的结构合理,产品经久耐用,系统可靠。

⑸可行性——要求系统投资或造价能控制在小区家庭能承受的范围之内本项目采用美国HONEYWELL总线报警系统VISTA-120一.主要使用设备性能报警主机:VISTA-120大型多功能报警控制/通讯主机防区特性:▪9个基本防区,3个键盘紧急按键防区,还有胁持防区▪防区9可设置响应时间为1 0毫秒或350毫秒▪可通过无线或总线方式,将防区扩展到1 28个控制特性:▪可以划分为8个独立子系统及3个公共子系统,可当作8台独立主机使用▪可选择使用4 1 46布/撤防开关锁或无线按钮控制▪支持4286模块通过电话监控主机▪224/1000条事件记录,可通过遥控编程下载或直接从键盘上查看▪支持150/250个分为7个级别的用户密码▪可设置出入及周边防区门铃警示▪留守及快速布防时自动旁路内部失效防区输出特性:▪内置拨号器,报警时自动拨号报告▪RS-232▪TCP/IP通讯协议:▪ADEMCO 3+1/4+1/4+2▪ADEMCO 4+2 Express▪ADEMC0 CONTACT I D▪RADIONlCS/SESCOA 3+1/4+1/4+2电气特性:▪7AH可充电后备电池,12VD(:▪1 6. 5 VAC,25VA变压器输出:▪警号电流:2Amps,12 VDC▪750mA辅助电流,12VDC▪最大支持96路继电器输出遥控编程:▪使用COMPASS(wlNDOWS版)软件对主机进行遥控编程门禁控制:▪主机内置有键盘控制门禁功能,新版本主机直接支持8/15个Vista—Key感应卡读卡器门禁模块先进时序:▪实时时钟控制应用场合机场、医院、博物馆、大中院校、大型百货公司、写字楼、政府机关、监狱等大型集中监控场所6160可编程英文液晶键盘·较大LCD液晶显示屏。

Honeywell 漫景综合保安系统 S6173 安全说明书

Honeywell 漫景综合保安系统 S6173 安全说明书

UROX.S6173Smoke­automatic Fire Detectors Page BottomSmoke­automatic Fire DetectorsSee General Information for Smoke­automatic Fire DetectorsSILENT KNIGHT BY HONEYWELL S6173 7550 MERIDIAN CIRMAPLE GROVE, MN 55369 USADetector Compatibility VelocityRange(fpm)DateofTime ofManufactureFirmwareVersionModel Application Type Restrictions Min Max Manufacture FirmwareVersion UpdateIDP­BEAM, IDP­BEAM­T, SK­BEAM, SK­BEAM­TOAP PB D2­­­IDP­FIRE­C0OAP P(IHD)D404000­­­IDP­ION, SK­IONOAP I D20500­­­IDP­PHOTO, IDP­PHOTOR, SK­PHOTO, SK­PHOTOROAP, D(I)P D204000­­­IDP­PHOTO­T, IDP­ACCLIMATE, SK­PHOTO­T, SK­ACCLIMATEOAP P(IHD)D204000­­­SD400­CPS OAP P D60300­­­SD505­AIS OAP I D2, D60300­­­SD505­APS OAP P D2, D60300­­­SD505­DUCT D(ST)P D2, D6*******­­­SD505­PHOTO OAP, D P D204000­­­SK­FIRE­CO OAP P(IHD)D404000­­­Detector Compatibility VelocityRange(fpm)PressureDifferentialBetweenSamplingTubeDateofTime ofManufactureFirmwareVersionModel Application Type Restrictions Min Max Min Max Manufacture FirmwareVersion UpdateIDP­PDUCT,IDP­PDUCT­R(a)D(ST)P D210040000.03 1.4­­­SK­DUCT(b)(c)D(ST)P D210040000.01 1.11­­­Base Model Related DetectorControl Unit Compatibility RestrictionsB210LP IDP­FIRE­C0 (CO), SK­FIRE­CO (CO)B2B501, B200S,IDP­FIRE­C0 (CO), SK­FIRE­CO (CO)B4 B210LP, B224RB,B224BIB2 IDP­6AB1151, 1151RIS, 2151, 1251, 2251, 3251, 7251, IDP­PHOTO, IDP­PHOTO­T, IDP­ION, IDP­HEAT, IDP­HEAT­HT, IDP­HEAT­ROR, IDP­ACCLIMATESD505­4AB SD505­AIS, SD505­APS B2SD505­6AB SD505­AIS, SD505­APS B2SD505­6RB SD505­AIS, SD505­APS, SD505­AHS B2SD505­6SB SD505­AIS, SD505­APS, SD505­AHS B2B2 ­ For connection to Listed control units with which compatibility was determined by test or a review of circuit parameters. Interconnection and compatible models indicated on installation wiring diagram for detector (base) and/or control unit.B4 ­ For connection to any manufacturer's Listed compatible control unit.D2 ­ For connection to Listed control units with which compatibility was determined by test or a review of circuit parameters. Interconnection and compatible models indicated on installation wiring diagram for detector (base) and/or control unit.D4 ­ For connection to any manufacturer's Listed compatible control unit.D6 ­ When using 2­wire bases Listing limited to specific system control unit. Information on compatible control unit indicated on installation drawing of control unit and/or detector. When using 4 wire bases, no restriction on compatibility.OAP ­ Open Area ProtectionPB ­ Projected BeamP ­ PhotoelectricIHD ­ Includes Integral Heat DetectorI ­ IonizationD(I) ­ Duct Detector ­ Installation Inside DuctD(ST) ­ Duct Detector ­ Sampling TubesD ­ Duct DetectorDate of Manufacture identifies the manufacturing start date of all product models that will use the specific Time of Manufacture Firmware Version. The date of manufacture is noncoded and in the format YEAR (in 4 digits), MONTH (in letters), DAY (in 2 digits).Time of Manufacture Firmware Version identifies a numerical and/or alphabetic series designation that is product and date­code specific and will only identify the Firmware Version at the time the product was manufactured. The numeric and/or alphabetic sequence is defined by the manufacturer.Firmware Version Update is a numerical and/or alphabetic sequential identification that is product and date­code specific and sequentially identifies the Firmware Version Update from the previous version of firmware. The numerical and/or alphabetic sequence is defined by the manufacturer.(a) ­ Suitable for use in ambient temperatures of 0­55 C (23­131 F).(b) ­ SK­DUCT duct housing can be used with the following compatible detector heads: IDP­PHOTO, IDP­PHOTOR, SK­PHOTO, SK­PHOTOR.(c) ­ Suitable for elevated temperatures up to 70 C.CO ­ Suitable for use as a carbon monoxide alarmLast Updated on 2015­03­12Questions?Print this page Terms of Use Page Top© 2015 UL LLC When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment database for additional information regarding this product's certification.The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow­Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow­Up Service. Always look for the Mark on the product.UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non­misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "© 2015 UL LLC".。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

摄像机配置指南—固定球机
JESC5系列吸顶式黑白球型摄像机
u 1/3" SONY/黑白CCD u 低照度:0.01Lux u 高品质画面600线 u 标准解像度 u 内置各种规格手动、自动光圈大镜头 u 低功率损耗 u 安装方便,免维护 u 适用于各类CCTV应用系统,特别是厅道等场所
1、系统容量:多少路视频输入,多少路音频输入? 多少路视频输出,多少路音频输出?
2、需要使用地图控制吗? 3、是否使用球机? 4、是否需要和门禁、报警联动?
Quest All 视音频系统配置指南
视音频矩阵:
Quest All 矩阵以矩阵总成的方式出现,也就是说您可以 直接购买 Input x Output 的视音频矩阵,唯一要注意的 是矩阵配置要大于至少要等于您的需求。
注意:若想实现防区联动,这种联动组只有15组
Ademco大型报警系统配置指南
Vista-
怎样和上位机集成?


4100SM单向报警串行接口 串行设备
考虑计算机,您是否需要串口扩充? 1
2
0
IP-2000双向报警、控制网络接口 局域网接口

总 考虑计算机,需要兼容10M网络
线
Ademco大型报警系统配置指南
和有多
4297延伸器
不4并 超接 过2 8
1
1 9个2742来自0前 面2
0 多
0距9 米离 7


线
4297延伸器
4297后面距离前所述不超过1200米
Ademco大型报警系统配置指南
您已经知道总线的布线和配置了,防区呢?
每 台
总线
Vista-
1
4293SN添 4193SN添
4208U添
2 加单个防区 加两个防区 加8个防区
插卡数量,+CPU卡一块
插卡数量超过23,须添加另外的机箱
其他机箱添加与输出路数相同的内联输出模块AVBLKI 含有输出的机箱要添加相应路数的内联输入模块AVBLKO
VideoBlox 视音频系统配置指南
板卡介绍
型号
描述
备注
AVBCPUX AVBARB
CPU 模块PAL制式 CPU 仲裁模块
占1个卡位

需要控制球机吗?
PIT422

需要Vista-120连动吗?
PIT232/232
摄像机配置指南—固定球机
JESC5系列吸顶式彩色球型摄像机
u 1/3" SONY彩色CCD u 低照度:0.1Lux u 高品质画面480线 u 标准解像度 u 内置各种规格手动、自动光圈大镜头 u 低功率损耗 u 安装方便,免维护 适用于各类CCTV应用系统,特别是厅道等场
报警接口软件JO8AI5

您是否需要和门禁联动?
报警接口软件JO8CI5

您是否需要和音频集成?
报警接口软件JO8BI5
VideoBlox 视音频系统配置指南
矩阵容量:
您需要多少路输入?
您需要多少路输出?
输出卡规格:8X / 16X
输入卡规格:16X 8/16/32/64 输入卡规格、数量
机箱尺寸(U)X2-1=插卡数量
AVB32LKI AVB32LKO
32路内联输入卡 32路内联输出卡
占1个卡位 多机箱时使用
VideoBlox 视音频系统配置指南
其他附件:

需要键盘副控?
副控键盘:
AVBPCKND:无显示 AVBPCK:无操纵杆 AVBPCKZ:内置操纵杆 AVBPCKC:内置操纵杆、16功能键 AVBPCKA :内置操纵杆、16功能键、喇叭
Quest All 视音频系统配置指南
控制软件:
您是否单机使用该软件?


网络版软件 是 您是否需要图形分控?
需要图形分控
+图形分控软件
否 单机版软件
Quest All 视音频系统配置指南

需要控制球机吗?
232/485转换器250
Quest All 视音频系统配置指南
控制软件: 是
您是否需要和报警联动?
0 多 总
直接接到总线上
到总线接线 不超过2米
线
Ademco大型报警系统配置指南
Vista-
您想使用继电器吗?

键盘总线

4204四继
4204四继
电器模块
电器模块
1
探测器总线
2
共可接8个, 布线遵从 键盘说明
0 多 4201SN单 总 继电器模块 线
4201SN单 继电器模块
共可接64 个,布线 遵从总线 说明
占3个卡位,并且要考 虑另外的CPU卡
AVB16M8 AVB16M16 AVB16M32 AVB16M64
视频输入卡
占1个卡位 16输入,8、16、32、 64路输出
VideoBlox 视音频系统配置指南
板卡介绍
型号
描述
备注
AVB8TOX 8路视频输出卡
占1个卡位
AVB16TOX 16路视频输出卡 8、16路输出带字符叠加
Ademco大型报警系统配置指南
Vista-

所有距离之和不超过1200米
同 样




4297延伸器
距 离
1


2 距离不够需要延伸,可以连接一个4297延伸器
不 超
0


1

2
总 总线使用RVS1.0x2非屏蔽双绞线
0
线
0

Ademco大型报警系统配置指南
Vista-

4297延伸器

之所最
A Honeywell Company
安防系统配置指南
报警 闭路电视监控
门禁 综合
Ademco大型报警系统配置指南
配置报警系统您需要知道什么?
1、系统容量:防区(就是能区分出来的最小单位,如 10个探测器接到一个防区上,您就不能区分是那个 探测器报警,只知道是该防区报警)
2、控制区域数量:您需要分成多少个区域单独控制, 如单独布撤防,这就是子系统的概念)
3、跟上位机如何连接(串口还是网络) 4、您需要使用继电器吗,需要多少个?
Ademco大型报警系统配置指南
每台Vista-120可以接入16个6139键盘控制8个子系统
某子系统需要 现场单独布撤防 加入一个6139
某子系统需要 现场单独布撤防 加入一个6139
使用RVV1.0x4电缆所有距离之和不超过400米
如何选择探测器? 我们通常所述的探测范围 L x W,就如上图中的描述,如:
DT7225: 7.6x9米 DT7235: 11x11米 DT7450: 15x18米
IS2260T: 18x18米 IS215T: 12x12米 IS150T: 15x12米
视音频系统配置指南
配置视音频系统您需要知道什么?
怎样选择探测器?
1、被动红外探测器: 单红外一般用于环境平和或要求不是很高的地方
双鉴探测器一般作为商业应用,有较好的防误报性能 和灵敏度
2、主动红外探测器: 直线探测,按照标称距离的85折成实际应用即可
Ademco大型报警系统配置指南
被动红外探测器探测范围的界定?
W
L 顶视图
侧视图
Ademco大型报警系统配置指南
相关文档
最新文档