UT61L1288LS-15中文资料
诺莱公司L50189系列产品说明书
Screw compressors BELT 4–37Capacity:0.43–5.78 m3/minIntelligence, innovation, reliabilityThe small power packagesmall, compact, powerfulgreat diversity of variantsclear, maintenance-friendly designsuper sound insulation as standard featureintelligent microprocessor controlsoptimal system efficiencyMaximum benefits for our customers:This premise holds true for everyone atALMIG.Our products benefit from the latest techni-ques in research and development and aremanufactured according to ISO 9001: 2000 /ISO 14001: 2004 / IRIS.They fulfil all acceptance criteria accordingto ISO 1217 – 3 annex C – 1996 and conformto the CE-guidelines.Even the most stringent conditions, such asDET NORSKE VERITAS, GERMANISCHERLLOYD, BUREAU VERITAS, LLOYD’S REGISTEROF SHIPPING, ABS among others, are for usat ALMIG a matter of course.ISO 9001ISO 14001Assembly, technique, highlightsᕡSeparating systemhighest compressed air quality through proven multi-stage separation ᕢAir Controlthe intelligence of the compressor;thinks, monitors, records (available in two versions)ᕣDrive systemhighly efficient, operationally safe V-belt drive ᕤAir endhigh performance,excellent efficiencyᕥCooling unitlarge surface-area radiators for lowest compressed air outlet temperatures and optimum thermostat-controlled coolant temperatures ᕦFanpowerful, efficient, high-performance ᕧDrive motorRobust drive motor with reservesManufacture Test Serviceᕤᕧᕦᕥᕡᕣᕢ.Air Control 1Air Control 3... mounted on a tank with refrigeration dryerBELT 4-15In any case, the series sets new standards for its power class with regard to quality,operational safety, service life and user BELT 4-37... mounted on a tankBELT 4-15BlowerComplete Control,。
施耐德电气 TeSys
Te Sy s®T电动机管理控制器选型手册施耐德电气在中国1987年,施耐德电气在天津成立第一家合资工厂梅兰日兰,将断路器技术带到中国,取代传统保险丝,使得中国用户用电安全性大为增强,并为断路器标准的建立作出了卓越的贡献。
90年代初,施耐德电气旗下品牌奇胜率先将开关面板带入中国,结束了中国使用灯绳开关的时代。
施耐德电气的高额投资有力地支持了中国的经济建设,并为中国客户提供了先进的产品支持和完善的技术服务,中低压电器、变频器、接触器等工业产品大量运用在中国国内的经济建设中,促进了中国工业化的进程。
目前,施耐德电气在中国共建立了77个办事处,26家工厂,6个物流中心,1个研修学院,3个研发中心,1个实验室,500家分销商和遍布全国的销售网络。
施耐德电气中国目前员工数近22,000人。
通过与合作伙伴以及大量经销商的合作,施耐德电气为中国创造了成千上万个就业机会。
施耐德电气 能效管理平台全球能效管理专家施耐德电气为世界100多个国家提供整体解决方案,其中在能源与基础设施、工业过程控制、楼宇自动化和数据中心与网络等市场处于世界领先地位,在住宅应用领域也拥有强大的市场能力。
致力于为客户提供安全、可靠、高效的能源,施耐德电气2010年的销售额为196亿欧元,拥有超过110,000名员工。
施耐德电气助您——善用其效,尽享其能!施耐德电气善用其效 尽享其能凭借其对五大市场的深刻了解、对集团客户的悉心关爱,以及在能效管理领域的丰富经验,施耐德电气从一个优秀的产品和设备供应商逐步成长为整体解决方案提供商。
今年,施耐德电气首次集成其在建筑楼宇、IT 、安防、电力及工业过程和设备等五大领域的专业技术和经验,将其高质量的产品和解决方案融合在一个统一的架构下,通过标准的界面为各行业客户提供一个开放、透明、节能、高效的能效管理平台,为企业客户节省高达30%的投资成本和运营成本。
● 选型指南 ......................................................................................................................2-3● 介绍 ................................................................................................................................4-5● 产品描述 .......................................................................................................................6-8● 功能 ............................................................................................................................. 9-10● 拓朴结构 .................................................................................................................... 11-12● 编程 ............................................................................................................................ 13-14● 产品特性 ...................................................................................................................15-18● 脱扣曲线 (19)● 订货号 .......................................................................................................................20-23● 尺寸与安装 ............................................................................................................. 24-25● 接线图 ...................................................................................................................... 26-29● 产品组合替换表 (30)目录电动机管理控制器Te Sys T选型指南保护元件Te Sys T 电动机管理控制器控制器Te Sys T 是一种电动机管理控制器,为单相或3相恒速交流电机提供电机保护,电机参数测量和监视功能;电机最大电流可达810A 。
UL-Series和DL-Series微型铜封电路保护器规格表说明书
UL(AC),DL(DC) SeriesUL489 Miniature Molded Case Circuit BreakersCurrent/ Voltage RatingUL-Series DL-SeriesCalibration Temperature Ambient Temperature Storage Temperature Terminal Torque (min/max)Electrical Life Mechanical Life Vibration ResistanceResistance to mechanical shocks 0.3 - 63A/ 240V AC, 0.3-32A/ 480Y/277V AC*0.3 - 63A/ 125/ 250V DC 40ºC (104ºF)-25ºC to +55ºC (-13ºF to 131ºF )-40ºC to +70ºC (-40ºF to 158ºF )2 Nm (17.7 lb.in.) / 2.5Nm (22.2 lb.in)6000 switching cycles ON/ OFF 10000 switching cycles ON/ OFF> 15g according to DIN EN 60069-2-59 during a load with I 1= 1.05 x I N 25g @ 11msIEC 60947-2Short Circuit Tested•Available in AC and DC models •DIN Rail Mounted •17.5mm width •Thermal Magnetic •Current Limiting•240V , 480Y/277V AC, 50/60Hz•125V DC (1 pole); 250V DC (2pole)•10kA Short Circuit Interrupting Capacity •HACR Type 40°C •Line/Load reversibleLISTED USE329510C.B.No.Poles Type 0.3-32A 40-63A 1AC 10kA @ 120, 240,10kA @ 120,277V 240V 2-3AC10kA @ 120, 240,10kA @ 120480Y/277V240VNo.Poles Type 0.3-3240-63A 1AC 15kA@240V 15kA@240V 2-3AC15kA@415V10kA@415VNo.Poles Type 0.3-32A 40-63A 1DC 10kA @ 125V 10kA @ 125V 2DC10kA @ 250V10kA @ 250VAltech Corp.®• 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • *One device dual voltage ratings.Short Circuit Interrupting Capacity According to UL 489Interrupting CapacityAccording to IEC 60947-2, DIN EN 60937-2PENDING8D-Characteristics AC1.05xRC1.35xRC10xRC16xRCD-Characteristics DC1.05xRC1.35xRC14xRC22.4xRC*The value of each characteristic is shown vertically beneath its corresponding heading.Characteristic Trip Boundaries Trip-Characteristics*ApplicationsC-Characteristics ACC-Characteristics DCThermal TripLighting Control CircuitsWiring Protection Business Equipment AppliancesTransformersPower Supplies HeatersMust not Trip>100ms Must Trip <1hr Must not Trip>100ms Must Trip at 100ms Magnetic TripLowInrush High InrushMotorsReactive LoadTelecommu-nications/Computer EquipmentPower Supplies1.05xRC1.35xRC5xRC10xRC1.05xRC1.35xRC7xRC14xRCWarning!This information should only be used as a selection guide. T he use of a Miniature Circuit Breaker in an application with a certain T rip-Characteristic always requires prototype testing! It is the responsibility of the circuit design engineer to select the appropriate Miniature Circuit Breaker for his specific application.1 Pole2 Pole3 Pole17.5 mm 36.5 m m36.8 m m35 mm 52.5 mm68.4 mm51.5 mm30.5 mm51.5 mm37.5 mm25.5 mm14.5 mm45 m m105.3 m m52.5 m m34.5 m m8467Dimensions in mmTrip CharacteristicVoltage Rating Rated Current No. of PolesApproval for heating,refrigerating and air conditioning devices.ApprovalCircuit DiagramShort Circuit RatingProduct SeriesIndividual Part Number is shownMarking DetailsAltech Corp.®• 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • C -TripCharacteristicLISTED USE329510C.B.Application Examples:Low inrush motors, resistive loads, wiring protection, receptacles,lighting, and control circuit applications. Relatively short thermal trip delay and medium magnetic trip point.Standard Pack: 12Weight:0.3-32A:1.74kg (3.83lb.)40-63A:1.98kg (4.37lb.)Standard Pack: 6Weight:0.3-32A:1.74kg (3.83lb.)40-63A:1.98kg (4.37lb.)Standard Pack: 4Weight:0.3-32A:1.74kg (3.83lb.)40-63A:1.98kg (4.37lb.)Rated Type/ Rated Current Cat. No. Voltage 0.3A 1C03UL 277V AC 0.5A 1C05UL 277V AC 1.0A 1C1UL 277V AC 1.6A 1C1.6UL 277V AC 2.0A 1C2UL 277V AC 3.0A 1C3UL 277V AC 4.0A 1C4UL 277V AC 5.0A 1C5UL 277V AC 6.0A 1C6UL 277V AC 8.0A 1C8UL 277V AC 10A 1C10UL 277V AC 12A 1C12UL 277V AC 13A 1C13UL 277V AC 15A 1C15UL 277V AC 16A 1C16UL 277V AC 20A 1C20UL 277V AC 25A 1C25UL 277V AC 30A 1C30UL 277V AC 32A 1C32UL 277V AC 40A 1C40UL 240V AC 50A 1C50UL 240V AC 60A 1C60UL 240V AC 63A 1C63UL 240V ACOne PoleThree PoleTwo PoleAdd-on Neutral PoleRated Type/ Rated Current Cat. No. Voltage 0.3A 2C03UL 480Y/277V AC 0.5A 2C05UL 480Y/277V AC 1.0A 2C1UL 480Y/277V AC 1.6A 2C1.6UL 480Y/277V AC 2.0A 2C2UL 480Y/277V AC 3.0A 2C3UL 480Y/277V AC 4.0A 2C4UL 480Y/277V AC 5.0A 2C5UL 480Y/277V AC 6.0A 2C6UL 480Y/277V AC 8.0A 2C8UL 480Y/277V AC 10A 2C10UL 480Y/277V AC 12A 2C12UL 480Y/277V AC 13A 2C13UL 480Y/277V AC 15A 2C15UL 480Y/277V AC 16A 2C16UL 480Y/277V AC 20A 2C20UL 480Y/277V AC 25A 2C25UL 480Y/277V AC 30A 2C30UL 480Y/277V AC 32A 2C32UL 480Y/277V AC 40A 2C40UL 240V AC 50A 2C50UL 240V AC 60A 2C60UL 240V AC 63A 2C63UL 240V ACRated Type/ Rated Current Cat. No. Voltage 0.3A 3C03UL 480Y/277V AC 0.5A 3C05UL 480Y/277V AC 1.0A 3C1UL 480Y/277V AC 1.6A 3C1.6UL 480Y/277V AC 2.0A 3C2UL 480Y/277V AC 3.0A 3C3UL 480Y/277V AC 4.0A 3C4UL 480Y/277V AC 5.0A 3C5UL 480Y/277V AC 6.0A 3C6UL 480Y/277V AC 8.0A 3C8UL 480Y/277V AC 10A 3C10UL 480Y/277V AC 12A 3C12UL 480Y/277V AC 13A 3C13UL 480Y/277V AC 15A 3C15UL 480Y/277V AC 16A 3C16UL 480Y/277V AC 20A 3C20UL 480Y/277V AC 25A 3C25UL 480Y/277V AC 30A 3C30UL 480Y/277V AC 32A 3C32UL 480Y/277V AC 40A 3C40UL 240V AC 50A 3C50UL 240V AC 60A 3C60UL 240V AC 63A 3C63UL 240V ACRated Type/ Rated Current Cat. No. Voltage 0.3-32A N32UL 480/277V AC 40-63A N63UL 240V ACStandard Pack: 6Weight:0.99kg (2.18 lb.)Standard Dual Connection Terminal•Box clamp terminals Top: 18-3 AWG;Bottom: 18-2 AWG (Line/Load reversible)•Ring tongue terminalsRing tongueBox clamp*May differ by manufacturer. T op terminal ring tongue max. thickness 1.6mm.18.3 mm (0.72 in.)M5 screw11.3 mm (0.44 in.)m a x . 8-12 m m (0.31-0.47 i n .)5.3 m m (0.21 i n .)UL - Series 10Altech Corp.®• 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • Application Examples:High inrush motors, transformers, power supplies, heaters and reactive loads. Relatively long thermal trip delay and very high magnetic trip point.LISTED USE329510C.B.Standard Pack: 12Weight:0.3-32A:1.74kg (3.83lb.)40-63A:1.98kg (4.37lb.)Standard Pack: 6Weight:0.3-32A:1.74kg (3.83lb.)40-63A:1.98kg (4.37lb.)Standard Pack: 4Weight:0.3-32A:1.74kg (3.83lb.)40-63A:1.98kg (4.37lb.)Rated Type/ Rated Current Cat. No. Voltage 0.3A 1D03UL 277V AC 0.5A 1D05UL 277V AC 1.0A 1D1UL 277V AC 1.6A 1D1.6UL 277V AC 2.0A 1D2UL 277V AC 3.0A 1D3UL 277V AC 4.0A 1D4UL 277V AC 5.0A 1D5UL 277V AC 6.0A 1D6UL 277V AC 8.0A 1D8UL 277V AC 10A 1D10UL 277V AC 12A 1D12UL 277V AC 13A 1D13UL 277V AC 15A 1D15UL 277V AC 16A 1D16UL 277V AC 20A 1D20UL 277V AC 25A 1D25UL 277V AC 30A 1D30UL 277V AC 32A 1D32UL 277V AC 40A 1D40UL 240V AC 50A 1D50UL 240V AC 60A 1D60UL 240V AC 63A 1D63UL 240V ACOne PoleThree PoleTwo PoleAdd-on Neutral PoleRated Type/ Rated Current Cat. No. Voltage 0.3A 2D 03UL 480Y/277V AC 0.5A 2D 05UL 480Y/277V AC 1.0A 2D 1UL 480Y/277V AC 1.6A 2D 1.6UL 480Y/277V AC 2.0A 2D 2UL 480Y/277V AC 3.0A 2D 3UL 480Y/277V AC 4.0A 2D 4UL 480Y/277V AC 5.0A 2D 5UL 480Y/277V AC 6.0A 2D 6UL 480Y/277V AC 8.0A 2D 8UL 480Y/277V AC 10A 2D 10UL 480Y/277V AC 12A 2D 12UL 480Y/277V AC 13A 2D 13UL 480Y/277V AC 15A 2D 15UL 480Y/277V AC 16A 2D 16UL 480Y/277V AC 20A 2D 20UL 480Y/277V AC 25A 2D 25UL 480Y/277V AC 30A 2D 30UL 480Y/277V AC 32A 2D 32UL 480Y/277V AC 40A 2D 40UL 240V AC 50A 2D 50UL 240V AC 60A 2D 60UL 240V AC 63A 2D 63UL 240V ACRated Type/ Rated Current Cat. No. Voltage 0.3A 3D 03UL 480Y/277V AC 0.5A 3D 05UL 480Y/277V AC 1.0A 3D 1UL 480Y/277V AC 1.6A 3D 1.6UL 480Y/277V AC 2.0A 3D 2UL 480Y/277V AC 3.0A 3D 3UL 480Y/277V AC 4.0A 3D 4UL 480Y/277V AC 5.0A 3D 5UL 480Y/277V AC 6.0A 3D 6UL 480Y/277V AC 8.0A 3D 8UL 480Y/277V AC 10A 3D 10UL 480Y/277V AC 12A 3D 12UL 480Y/277V AC 13A 3D 13UL 480Y/277V AC 15A 3D 15UL 480Y/277V AC 16A 3D 16UL 480Y/277V AC 20A 3D 20UL 480Y/277V AC 25A 3D 25UL 480Y/277V AC 30A 3D 30UL 480Y/277V AC 32A 3D 32UL 480Y/277V AC 40A 3D 40UL 240V AC 50A 3D 50UL 240V AC 60A 3D 60UL 240V AC 63A 3D 63UL 240V ACRated Type/ Rated Current Cat. No. Voltage 0.3-32A N32UL 480/277V AC 40-63A N63UL 240V ACStandard Pack: 6Weight:0.99kg (2.18 lb.)Standard Dual Connection Terminal•Box clamp terminals T op: 18-3 AWG;Bottom: 18-2 AWG (Line/Load reversible)•Ring tongue terminalsRing tongueBox clamp*May differ by manufacturer. T op terminal ring tongue max. thickness 1.6mm.18.3 mm (0.72 in.)M5 screw11.3 mm (0.44 in.)m a x . 8-12 m m (0.31-0.47 i n .)5.3 m m (0.21 i n .)D -TripCharacteristicUL - SeriesC-Trip (DC) Characteristic Application Examples: Telecommunication equipment,computer equipment, uniterruptable power supplies.Standard Pack: 12Weight:0.3-32A:1.86kg (4.1lb.)40-63A:2.10kg (4.6lb.)Standard Pack: 6Weight:0.3-32A:1.86kg (4.1lb.)40-63A:2.10kg (4.6lb.)Rated Type/ RatedCurrent Cat. No. Voltage0.3A1C03DL125V DC0.5A1C05DL125V DC1.0A1C1DL125V DC1.6A1C1.6DL125V DC2.0A1C2DL125V DC3.0A1C3DL125V DC4.0A1C4DL125V DC5.0A1C5DL125V DC6.0A1C6DL125V DC8.0A1C8DL125V DC10A1C10DL125V DC12A1C12DL125V DC13A1C13DL125V DC15A1C15DL125V DC16A1C16DL125V DC20A1C20DL125V DC25A1C25DL125V DC30A1C30DL125V DC32A1C32DL125V DC40A1C40DL125V DC50A1C50DL125V DC60A1C60DL125V DC63A1C63DL125V DCOne Pole Two PoleRated Type/ RatedCurrent Cat. No. Voltage0.3A2C03DL250V DC0.5A2C05DL250V DC1.0A2C1DL250V DC1.6A2C1.6DL250V DC2.0A2C2DL250V DC3.0A2C3DL250V DC4.0A2C4DL250V DC5.0A2C5DL250V DC6.0A2C6DL250V DC8.0A2C8DL250V DC10A2C10DL250V DC12A2C12DL250V DC13A2C13DL250V DC15A2C15DL250V DC16A2C16DL250V DC20A2C20DL250V DC25A2C25DL250V DC30A2C30DL250V DC32A2C32DL250V DC40A2C40DL250V DC50A2C50DL250V DC60A2C60DL250V DC63A2C63DL 250V DC For the latest on Altech Circuit Breakers specifications please visit /breaker.Standard DualConnection Terminal•Box clamp terminalsT op: 18-3 AWG;Bottom: 18-2 AWG(Line/Load reversible)•Ring tongue terminalsRingtongueBoxclamp*May differ by manufacturer. T op terminal ring tongue max. thickness 1.6mm.18.3 mm(0.72 in.)M5 screw11.3 mm(0.44 in.)max.8-12mm(.31-.47in.)5.3mm(.21in.)LISTEDUSE329510C.B.DL - Series++–––+Warning!Correct polarity must be observedwhen connecting the DC circuit breakers.12D-Trip (DC) Characteristic Application Examples: Telecommunication equipment,computer equipment, uniterruptable power supplies.Standard Pack: 12Weight:0.3-32A:1.86kg (4.1lb.)40-63A:2.10kg (4.6lb.)Standard Pack: 6Weight:0.3-32A:1.86kg (4.1lb.)40-63A:2.10kg (4.6lb.)Rated Type/ RatedCurrent Cat. No. Voltage0.3A1D03DL125V DC0.5A1D05DL125V DC1.0A1D1DL125V DC1.6A1D1.6DL125V DC2.0A1D2DL125V DC3.0A1D3DL125V DC4.0A1D4DL125V DC5.0A1D5DL125V DC6.0A1D6DL125V DC8.0A1D8DL125V DC10A1D10DL125V DC12A1D12DL125V DC13A1D13DL125V DC15A1D15DL125V DC16A1D16DL125V DC20A1D20DL125V DC25A1D25DL125V DC30A1D30DL125V DC32A1D32DL125V DC40A1D40DL125V DC50A1D50DL125V DC60A1D60DL125V DC63A1D63DL125V DCOne Pole Two PoleRated Type/ RatedCurrent Cat. No. Voltage0.3A2D03DL250V DC0.5A2D05DL250V DC1.0A2D1DL250V DC1.6A2D1.6DL250V DC2.0A2D2DL250V DC3.0A2D3DL250V DC4.0A2D4DL250V DC5.0A2D5DL250V DC6.0A2D6DL250V DC8.0A2D8DL250V DC10A2D10DL250V DC12A2D12DL250V DC13A2D13DL250V DC15A2D15DL250V DC16A2D16DL250V DC20A2D20DL250V DC25A2D25DL250V DC30A2D30DL250V DC32A2D32DL250V DC40A2D40DL250V DC50A2D50DL250V DC60A2D60DL250V DC63A2D63DL250V DC LISTEDUSE329510C.B.DL - SeriesStandard DualConnection Terminal•Box clamp terminalsTop: 18-3 AWG;Bottom: 18-2 AWG(Line/Load reversible)•Ring tongue terminalsRingtongueBoxclamp*May differ by manufacturer. T op terminal ring tongue max. thickness 1.6mm.18.3 mm(0.72 in.)M5 screw11.3 mm(0.44 in.)max.8-12mm(.31-.47in.)5.3mm(.21in.)++–––+Warning!Correct polarity must be observedwhen connecting the DC circuit breakers.13Altech Corp.®• 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • Type/ Cat No.DescriptionContacts TypeStd PkH10UL 1 Auxiliary Contact 1NO 6H11UL 2 Auxiliary Contacts 1NO + 1NC 6H12UL 3 Auxiliary Contacts 1NO + 2NC 6H21UL 3 Auxiliary Contacts 2NO + 1NC 6HLS11L*1 Auxiliary/1 Signal Contact 1CO + 1CO (Signal)6Max. Operating Type/ Cat No.Description Current @ Un Std Pk FA12UL 12V AC/DC 1.3A 5FA24UL 24V AC/DC 0.6A 5FA48UL 48 - 72V AC/DC 0.2A50.25A @ 110V FA110UL0.5A @ 240V 50.58A @ 277V110 - 240V AC/DC,277V ACRated Operating 10A@240V AC Currents3A@110V AC 1A@220V AC Minimum Contact Load 1mA @ 24V DC Torquemax. 0.8Nm (7 lb.in)Wire Range :Single Wire 1.0mm² - 2.5mm² (18-14 AWG)Stranded Wire 1.0mm² - 1.5mm² (18-16 AWG)Stranded Wire 1.0mm² - 1.5mm² (18-16 AWG)with FerruleType/ Cat No.Rated Current InRated Voltage Std Pk N32UL 0.3 - 32A 480Y/277V AC 6N63UL40 - 63A240V AC6UL/DL Series AccessoriesAuxiliary Contact, Alarm SwitchShunt TripNeutral Pole8.8 mm63.8 mm6 mm45 m m87 m m 52.7 m m17.7 m m51.5mm 37.5mm25.5mm 52.5m m45m m34.5m m36.5m m36.8m m105.3m m6mm7mm8mm 14.5mm17.5mm30.5mm 51.5mm 68.4mm4mm89.5 m m45 m mc a . 180-20045 m m17.5 mm21.8 mmAWG 236 mm68.4 mm 43.6 mm45 m m88 m m9 mm68.4 mm43.8 mm63.8 mm6 mm12.4 mmLISTED C.B. ACC.3NY7E335632For mounting instructions please refer to page 43.Dimensions HxxUL.Dimensions HLS11L.Dimensions NxxUL, FAxxULDimensions UA120ULType/ Cat No.Line Voltage V E Std PkUA120UL120V AC, 60Hz5Reset-Hold Voltage = 0.85 x V EDrop-Out Voltage = 0.35 ~ 0.7 x V EV E = Rated Voltage* UL PendingUndervoltage Trip*Type/ Cat No.Std Pk E98341910Mounting Screw 34mmto connect the auxiliary contact and shunt trip or neutral Pole to the circuit breaker.Type/ Cat No.Std Pk EASS10Lock-out AdapterType/ Cat No.Std Pk BS.UL100Touch Protection Capsto cover the terminal screw holes on the switching devices, neutral Poles and shunt trips for increased touch protection.14Altech Corp.®• 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • “C” Magnetic Trip Parameters Rated current 0.3A to 63A.1. Hold for a minimum of 100ms at surge of 5 times rated current.2. Trip in under 100ms at 10 times rated current.“D” Magnetic Trip Parameters Rated current 0.3A to 63A.1. Hold for a minimum of 100ms at surge of 10 times rated current.2. Trip in under 100ms at 16 times rated current.10-34x10-310-24x10-210-10.41410141040601234568102040100Multiple of Rated CurrentS e c o n d sM i n u t e sT r i p p i n g t i m e tThermal Overload“Must T rip” < 1 hr = 135% RC “Must Not Trip” > 1 hr = 105% RC1.05-1.35xI N 0.3A Through 10A Rated Current 10-34x10-310-24x10-210-10.41410141040601234568102040100Multiple of Rated CurrentS e c o n d sM i n u t e sT r i p p i n g t i m e tThermal Overload“Must T rip” < 1 hr = 135% RC “Must Not Trip” > 1 hr = 105% RC1.05-1.35xI N 12A Through 63A Rated Current1.05-1.35xI N1234568102040100Multiple of Rated Current10-34x10-310-24x10-210-10.4141014104060S e c o n d sM i n u t e sT r i p p i n g t i m e t16Thermal Overload“Must T rip” < 1 hr = 135% RC “Must Not T rip” > 1 hr = 105% RC0.3A Through 10A Rated Current10-34x10-310-24x10-210-10.4141014104060123451668102040100Multiple of Rated CurrentS e c o n d sM i n u t e sT r i p p i n g t i m e tThermal Overload“Must T rip” < 1 hr = 135% RC “Must Not T rip” > 1 hr = 105% RC1.05-1.35xI N 12A Through 63A Rated CurrentUL Series (AC) Trip CurvesC (AC) Trip CurveD (AC) Trip Curve10-34x10-310-24x10-210-10.41410141040601234567810142040100Multiple of Rated CurrentS e c o n d sM i n u t e sT r i p p i n g t i m e tThermal Overload“Must Trip” < 1 hr = 135% RC “Must Not T rip” > 1 hr = 105% RC1.05-1.35xI N 0.3A Through 10A Rated Current 1.05-1.35xI N1234578102040100Multiple of Rated Current 10-34x10-310-24x10-210-10.4141014104060S e c o n d sM i n u t e sT r i p p i n g t i m e t14Thermal Overload“Must Trip” < 1 hr = 135% RC “Must Not T rip” > 1 hr = 105% RC12A Through 63A Rated Current 10-34x10-310-24x10-210-10.41410141040601234568101422.440100Multiple of Rated CurrentS e c o n d sM i n u t e sT r i p p i n g t i m e tThermal Overload“Must T rip” < 1 hr = 135% RC “Must Not Trip” > 1 hr = 105% RC1.05-1.35xI N 0.3A Through 10A Rated Current10-34x10-310-24x10-210-10.41410141040601234514681022.440100Multiple of Rated CurrentS e c o n d sM i n u t e sT r i p p i n g t i m e tThermal Overload“Must T rip” < 1 hr = 135% RC “Must Not T rip” > 1 hr = 105% RC1.05-1.35xI N 12A Through 63A Rated CurrentUL Series (DC) Trip CurvesC (DC) Trip CurveD (DC) Trip Curve“C” Magnetic Trip Parameters Rated current 0.3A to 63A.1. Hold for a minimum of 100ms at surge of 7 times rated current.2. Trip in under 100ms at 14 times rated current.“D” Magnetic Trip Parameters Rated current 0.3A to 63A.1. Hold for a minimum of 100ms at surge of 14 times rated current.2. Trip in under 100ms at 22.4 times rated current.16Short Circuit Current I [kA]Time Basis:t=8.3msUL/ DL Series Internal ResistanceUL Series Let-through Energy I 2t Diagram, D Trip 1 poleRated CurrentTrip Characteristic (A)C D (Ohm)(Ohm)0.316.862016.86200.5 6.8540 6.00091.0 1.7000 1.75601.60.58700.58702.00.41900.41903.00.20200.20204.00.10900.10905.00.06540.06546.00.05280.04918.00.02780.0240100.02160.0187120.00840.0085130.00840.008515/ 160.00850.0076200.00670.0064250.00500.004130/ 320.00320.0027400.00250.0022500.00190.001860/ 630.00180.0017For other Trip/Pole configurations use the following correction factors:C T rip 1 pole + 0.84 x curve value C T rip 2 pole + 0.71 x curve value C T rip 3 pole + 0.92 x curve valueD T rip 1 pole + 1.00 x curve value D T rip 2 pole + 0.87 x curve value D T rip 3 pole + 1.08 x curve value。
华氏电梯8部分产品说明书
8PARTS MANUAL 8.1LIFT ASSEMBLY8.2LIFT ASSEMBLY PARTS LISTITEM QTY DESCRIPTION PART #1 1 TOWER WELDMENT, POWER SIDE 4-1010WELDMENT 4-0766 2 2 CARRIAGEBEARING 2-0772 3 8 GLIDENIPPLE 6-0000 4 4 GREASE7 2 PIN, CABLE EQUALIZATION 1-1887PULLEY 1-18988 6 2-POST9 2 HITCH PIN, 1/8” DIA 6-184111 8 LOCKWASHER,1/2”ID 6-0059 13 8 FLAT WASHER, 1/2”ID SAE 6-02481/2”-13UNC 6-0035NUT,14 13 HEXPIN 1-233715 2 SAFETY16 4 SNAP RING ¾” EXT 6-244517 8 FLAT WASHER, 51/64”ID x 1”OD x 1/16”THK. 6-080818 1 SAFETY DOG WELDMENT, POWER SIDE 2-190119 4 SELF TAPPING SCREW, #10 X 3/8” LG. 6-0169SPRING 1-111520 2 SAFETY21 6 SELF TAPPING SCREW, #12 x 1/2”LG. 6-113422 3 SHOULDER BOLT, 3/8”DIA. x 1”LG. 6-0206PULLEY 1-041523 2 SAFETY24 3 SAFETY CABLE PULLEY 1-111625 1 SHOULDER BOLT, 3/8” x 1 1/2” LG. 6-08015/32” 6-2074 26 1 THIMBLE,DECAL 6-1767 27 1 CAPACITYPLATE 6-111128 1 SERIAL29 1 TOWER WELDMENT, SLAVE SIDE 4-101130 1 SAFETY DOG, SLAVE SIDE 2-087231 1 SHOULDER BOLT, 3/8”DIA. x 1 1/2”LG. 6-0801BAR 1-1380 32 1 ACTUATORGUARD 6-140433 1 FOAM34 1 CROSSMEMBERWELDMENT 2-1952 35 4 CROSSMEMBER PULLEY PIPE, 1/2"LG. 1-16233/4”ID 6-0738 36 16 FLATWASHER,37 2 CROSSMEMBER PULLEY PIPE, 1 3/4"LG. 1-162638 2 CROSSMEMBER PULLEY SHAFT 2-125139 4 COTTER PIN, 1/8”DIA. x 1 ½”LG. 6-097840 1 SAFETY COVER cw/DECALS, POWER SIDE 0-020441 1 SAFETY COVER cw/DECALS, SLAVE SIDE 0-0203LOCKSPRING 1-294242 4 ARM43 4 SPRING RETAINER CAP 6-308644 4 ARM LOCK HANDLE WELDMENT 1-291445 4 HEX BOLT, 5/16”-18UNC x 3/4” LG. 6-0423PIN 2-159446 4 ARM47 4 HEX BOLT, 5/16”-18UNC x 1 1/4” LG. 6-2059RESTRAINTGEAR 1-2618 48 4 ARM3/8UNCx3/4”LG. 6-0030BOLT,49 4 HEX50 2 INNER ARM WELDMENT 3-0924ITEM QTY DESCRIPTION PART #WELDMENT 3-0920ARM51 2 OUTER52 2 LOCKING ARM ASSEMBLY cw/ARM RESTRAINT PIN 4-1118-6PADASSEMBLY 1-263453 4 STACK54 3 HEX BOLT, ¼” x ¾” LG 6-0178PAD 3-0872 55 4 RUBERWELDMENT 2-1993 56 4 STACKPAD57 4 STACK PAD ADAPTER 3” 1-199358 4 STACK PAD ADAPTER 6” 2-158059 2 STACK PAD ADAPTER HOLDER 1-2012ID 6-00561/4”60 10 LOCKWASHER,61 10 ROUND HEAD SCREW, 1/4”-20UNC x 3/8” LG. 6-13533/4”-10UNC 6-0737 NUT,62 10 HEX3/4”ID 6-0738 WASHER,63 10 FLAT64 10 WEDGE ANCHOR, 3/4”-10UNC x 5 1/2”LG. 6-1379KNOB 6-113565 1 PLASTIC66 1 SAFETY RELEASE HANDLE 1-111367 8 HEX BOLT, 1/2”-13UNC x 1 1/4” LG. 6-0046GROMMET 6-1507 68 3 RUBBERCABLE 1-178669 2 EQUALIZING70 1 SAFETY RELEASE CABLE 1-205871 7 HEX HD. NUT 1/4”NC 6-003272 2 6/32 SCREW (ELECTRICAL BOX) 6-146673 1 MICROSWITCH 6-091674 1 LIMIT SWITCH MTG. BRACKET 2-114375 1 ELECTRICAL UTILITY BOX 6-1403CONNECTOR 6-113376 1 CABLE77 1 ELEC. CABLE 12/3 x 117”LG. 6-1173EXTENSION 1-137978 1 ACTUATOR79 1 HEX HD. BOLT 1/4”NC x 2”LG. 6-074180 2 HEX HD. BOLT 1/4”NC x 1 1/4”LG. 6-002781 1 HEX HD. BOLT 1/4”NC x 1 ½”LG. 6-020582 2 SHOULDER BOLT, 3/8”DIA. x 5/8”LG. 6-0069NUT,5/16”-18UNC 6-0294 83 2 HEXBRACKET 1-1378 84 1 ACTUATORMTG.85 2 WIRE ROPE CLIP, 1/16” 6-206086 3 ELECTRICAL CABLE CLIP, 5/8” ID 6-17591/2” 6-0536 87 6 TUBECLAMP,88 4 FLATWASHER, 3/8”ID SAE 6-006289 8 FLATWASHER, 5/16”ID 6-029590 1 OUTER ARM WELDMENT F.R. 2-229691 1 OUTER ARM WELDMENT F.L. 2-230092 1 TELESCOPIC ARM ASSEMBLY C/W ARM RESTRAINT PIN F.R. 4-1146-693 1 TELESCOPIC ARM ASSEMBLY C/W ARM RESTRAINT PIN F.L. 4-1145-694 2 INNER ARM WELDMENT 2-227995 4 ALLEN HEAD FLAT SCREW ¼”- 20 X ¾” LG. 6-108696 2 INTERMEDIATE ARM WELDMENT 2-228298 4 ¼” FLAT WASHER SAE 6-00608.3HYDRAULIC SYSTEM8.4HYDRAULIC SYSTEM PARTS LISTITEM QTY DESCRIPTION PART #1 1 POWER PACK, 208-230V, 1PH 6-2055POWER PACK, 208-230V, 3PH 6-2665DECAL 6-2094OPERATION”2 1 “LIFT5/16”-18UNC 6-0294NUT,3 4 HEXWASHER,5/16”I.D. 6-0674 4 4 LOCKROD 2-1254 5 2 PISTONTUBE 2-1255016 2 CYLINDER7 2 MALE NIPPLE, 1/4”NPT 6-20958 2 1/8”NPT TO 1/4” JIC 6-02809 2 FLOWCONTROL 6-151010 2 PISTON 1-146711 2 PISTON SEAL KIT 0-033712 4 FLATWASHER,5/16”I.D. 6-02955/16”-18UNCx1”LG. 6-0293BOLT,13 4 HEXTEE 6-150614 1 BRANCH15 1 HYDRAULIC HOSE (LONG) 2-148616 1 HYDRAULIC HOSE (SHORT) 2-1230KIT 0-033817 2 GLAND18 2 1/4”CAP 6-1884JIC* CYLINDER ASSEMBLY (NOT INCL. FLOW CONTROL) 3-0621013 PH POWERPACK INCLUDES THE FOLLOWING (NOT SHOWN)* 1 CONTACTOR BOX (REMOVE JUMPER & WIRE FOR 3PH) 6-1575* 1 CONTACTORBRACKET 2-1130PLATE 1-1369 * 1 COVER* 2 HEX BOLT, ¼”-NC x 1” LG 6-0008¼” 6-0056 * 4 LOCKWASHER,* 2 HEX NUT, ¼”-NC 6-0032RELIEF 6-0094 * 2 STRAIN14/4 8-0287 * 2FTCABLE,8.5POWER PACK:8.6POWER PACK PARTS LIST:#6-2055 (AB-1381) 208-230V/1PH/60Hz#6-2665 (AD-1044) 208-230V/3PH/60HzITEM QTY. DESCRIPTION PART #6-1087CHECK1 1 VALVECARTRIDGE6-2136AUTOHOISTINSTALLATION2 1 LABEL6-1376&BLADDERCAP4 1 BREATHER6 1 MOTOR AC 208-230V. 2HP/1PH/60Hz, BLK 6-24742HP/3PH/60Hz,208-230V.BLK 6-1079AC1 MOTOR6-2149AUTOHOIST7 1 LABELWARNING9 1 SPRING 0.480” x 0.063” x 0.42” COMP 6-215121.5”6-2152ODx10 1 RETURNHOSE3/8”6-2153NUTTUBE11 1 COMPRESSION6-2154SLEEVE12 1 COMPRESSIONTUBE6-2155AUTOHOISTUNIVERSAL13 1 ENDHEAD14 1 PUMPASSY 2.5 CC/REV. SHORT SPLINE 6-195815 1 RELIEF ASSEMBLY FIXED 190 BAR 6-131916 1 VALVE CARTRIDGE RELEASE MANUAL 6-088017 1 WIRING ASSEMBLY AC 1PH FENNER 6-2473TORX6-10903.00”G8x18 2 BOLT5/16”-246-07741.260”SAE9T-20/4019 1 COUPLING6-2157SAE20 1 PLUMBINGPLUG9/16”21 1 SEAL SHAFT 0.500” x 1.00” x 0.25” 6-215822 1 WASHER 0.338” x 0.625” x 0.060” STEEL 6-21596-21613/8”NPT24 1 PLUMBINGPLUG25 1 PLUMBING MAGNET 6-216227 2 SCREW TAPTITE M6 x 1.0 12MM TORX 6-216428 1 COVER ASSY SUCTION 6-2165ADJ.6-2166INLETHOSECLAMP29 1 PLUMBING1.00”6-1392SHCSx30 1 BOLT5/16”-186-2167STEEL0.250”31 1 NUT ¾”-16 x 1” HEX xTOOTHLOCK 6-2168INT.32 1 WASHER¾”33 1 BRACKET – HANDLE ASSY REL BLACK 6-077634 4 BOLT M6 x 1.0 35MM SOC HD 6-2169HI-COLLARLOCK6-2170 35 4 WASHER¼”37 4 BOLT #12-24 x 0.50’ HEX WSHRHD 6-109138 1 PLUMBING ASSY INLET 17.24 (3) 6-0786CAPASSEMBLY 6-1089VALVE39 1 RELIEF22.50”OSBLK 6-1399 40 1 TANK6.7PLASTICWHITE6-1846LONG8”41 1 CABLETIE6-0875BUNA42 1 O-RING2-348。
德特威勒产品手册可编辑
DMD
内模板
外模板
模板
(5-8um半径)
(0-23um半径)
1
0.33ps/m
0.33ps/m
2
0.27ps/m
0.35ps/m
3
0.26ps/m
1300nm
台阶(双向平均值)
≤0.10
dB
不均匀性(整个光纤长度)和衰减点不连续性
≤0.10
dB
背向散射衰减系数差异(双向测试)
≤0.10
dB/km
几何特性
芯径
62.5±2.5
um
包层直径
125.0±1.0
um
包层不圆度
≤1.0
%
涂层直径
242±7
um
涂层/包层同心度误差
≤12.0
um
涂层不圆度
≤6.0
unilanR MPS六类屏蔽配线架框架47
unilanR MS六类屏蔽配线架框架47
unilanR六A类屏蔽线缆48R六A类屏蔽配线架50
unilanR七类屏蔽线缆51
unilanR七A类屏蔽线缆54
unilanR GG-45系列7类模块55
Unipatch PS系列7A类模块56
%
芯/包层同心度误差
≤1.5
um
Unilan?万兆光纤特性
Unilan?德特威勒万兆多模光纤特性:
满足IEC60793-2-10A1b、IEEE802.3ae、Bellcore、EIA/TIA-492AAAC、ISO11801OM3、TIA/EIA-455和TIA568C.3-2009标准,在850nm处可以支持万兆以太网速率达300米及支持1000Base-SX达900米距离,同时又可向下兼容目前的1G,100Mbps,10Mbps以太网应用。
EATON 电子熔断器系列C的电子熔断器与DIGITRIP RMS 系列的说明书
Master Connection Diagram Series C R-Frame Circuit Breaker with DIGITRIP RMS Trip Units1Instruction Leaflet IL29C714LEffective October 2012Master Connection Diagram Series C R-Frame Circuit Breaker with DIGITRIP RMS T rip UnitsEATON CORPORATIONLINEREV.123610 18101910/750/1050INDEX DIAGRAMSTRIP UNIT AND ACCESSORY MOUNTING LOCATIONS TERMINATION DIAGRAM22CONNECTIONS FOR RMS 700180023241232225A B C D E 8101910/750/1050MOTOR OPERATOR CONNECTIONCONTROL F G H I J K L M N 2324RD BREAKER GROUND FAULT AND REFERENCESFRAME INSTRUCTIONSRMS 500AUXILIARY SWITCHALARMSWITCH SHUNT0P25I.L.NO.UNDERVOLTAGE RELEASE LOW ENERGY SHUNT MOTOR OPERATOR TERMINAL BLOCKRMS 600RMS 700RMS 800RMS IN SERIES C FRAME RMS 5101129-8521129-8531129-854RD MASTER CONNECTION DIAGRAM INDEXRMS 610RMS 810RMS 3101129-8861129-8882627RD MASTER CONNECTION DIAGRAM Cat No. EOPTOBC CD BLOCK CONNECTION2627RD MASTER CONNECTION DIAGRAM - RG310+ Trip Unit2Instruction Leaflet IL29C714LEffective October 2012Master Connection Diagram Series C R-Frame Circuit Breaker with DIGITRIP RMS T rip UnitsEATON CORPORATION STABINDEDICATED'b'CONTACTINTERNALLY ONRHS810750,910 &MODULERMSDIELECTRICENERGY SHUNTNOTE:THE MAXIMUM NUMBER OF ACCESSORIES THAT MAY BE INSTALLED IN ANY ONE CIRCUIT BREAKER I S LIMITED BY THE NUMBER OF PHYSICAL MOUNTING POSITIONS.RD MASTER CONNECTION DIAGRAM T RIP U NIT AND A CCESSORY M OUNTING L OCATIONS9103Instruction Leaflet IL29C714LEffective October 2012Master Connection Diagram Series C R-Frame Circuit Breaker with DIGITRIP RMS T rip UnitsEATON CORPORATION CODED LEADBLOCKITYPICAL LEAD TERMINATIONRD MASTER CONNECTION DIAGRAMT E R M I N A T I O N D I A G R A MTERMINAL FOR TRIP FOR ACCESSORYCONNECTIONS ONLYCONNECTIONS ONLYFRONT FIXED SIDE SECONDARY SECONDARY CONNECTORS FUR TRIP FOR ACCESSORY TERMINATION C COLOR CODEDVIEW MOUNTEDTYPICAL LEAD TERMINATIONMOUNTED BREAKER PIN WAMP 'MULTIMATE'TYPE P/N 66099-4'MULTIMATE'A90067-4FOR EXTRACTION305183TYPICAL DISCDNNECT AS VIEWED FROM BTERMINAL BLOCKSCONNECTIONS ONLYCONNECTIONS WIRING MALE FEMALE HANDCRIMP4Instruction Leaflet IL29C714LEffective October 2012Master Connection Diagram Series C R-Frame Circuit Breaker with DIGITRIP RMS T rip UnitsEATON CORPORATION CRTOP1I FLUXISHUNT TRIPIWHT+AII II II RMSII III I I IWHTI III III IBLKII IIWHTIIIIIBLKII IIWHTI I IIII I 1110I III I I IISEE19AND NOTE 2ONB R E A K E R S EQUIPPED WITHAFAULT17TIME310TRIPUNIT.I N C L U D EAN D 9,CIRCUIT NOT FOR USE ONSCRRD MASTER CONNECTIONDIAGRAMRMS N O N -G R O U N D F A U L T T R I P U N I T CONNECTIONSA B R E A K E R S5Instruction Leaflet IL29C714LEffective October 2012Master Connection Diagram Series C R-Frame Circuit Breaker with DIGITRIP RMS T rip UnitsEATON CORPORATIONLC RTOP END--------------------------IIENDBASIC BREAKER INTERNAL CONNECTIONS(PARTIALONLY)EXTERNAL SHORTING STRAPS M U STDURINGSHEET 18A N DNOTE SHEET17TESTING ANDOPERATING GFP ZONEINTERLOCKINGC4,N.P.SIDE BREAKERRD MASTER CONNECTION DIAGRAMRD W I TH RMS U NIT -G ROUND F AULT E XTERNAL CONNECTIONS B REAKERS6Instruction Leaflet IL29C714LEffective October 2012Master Connection Diagram Series C R-Frame Circuit Breaker with DIGITRIP RMS T rip UnitsEATON CORPORATION BREAKER STYLESENSOR RATINGRATINGFLUX IBOTTOMENDEXTERNAL SHORTINGSTRAPSBEPLACENO.14OR N O.PERAND OPERATINGPERO N NEUTRALSENSORCDNNCTIONS.NP.SIDEBREAKERNEUTRAL SENSOR RATIO M U S T MATCHSENSORSBREAKERNEUTRALSO THAT POLARITYRELATIONSHIPTOWARDSI SIDENTICALSHEET 18A ND1SHEET 17F ORNEUTRALZONEC4,RD MASTER CONNECTION DIAGRAMRD RMS U NIT -G ROUND F AULT E XTERNAL CONNECTIONS RESIDUAL B REAKERSFRAMEብ7Instruction Leaflet IL29C714LEffective October 2012Master Connection Diagram Series C R-Frame Circuit Breaker with DIGITRIP RMS T rip UnitsEATON CORPORATIONBREAKERNEUTRAL STYLEFRAMESENSOR RATING RATINGAMPSLC R TOP END12500IELECTRODEIGFPT.B.EXTERNAL SHORTING STRAPS MUST BE I N PLACEDURING NO.14OR NO.12COPPER WIRE PER I.L.1053TESTING ANDOPERATING PERINSTRUCTIONNEUTRAL SENSORSECONDARYSIDE BREAKERNEUTRAL SENSOR RATIO MUSTMATCHI N BREAKER FRAMEN E U T R A L S E N S O R S O T H A T P O L AR I TYTOWARDS SOURCE I SIDENTICALSHEET 18AND NUTE 1ON SHEET 17FORFIRAND NEUTRAL SENSORSGFPINTERLOCKINGC4,RD MASTER CONNECTIONDIAGRAMRD W I TH RMS U NIT -G ROUND F AULT E XTERNAL C ONNECTIONS 3PH S OURCE GROUND B REAKERSAMPSብ8Instruction Leaflet IL29C714LEffective October 2012Master Connection Diagram Series C R-Frame Circuit Breaker with DIGITRIP RMS T rip UnitsEATON CORPORATION SHUNT TRIP,A\\:.,A>RESIDUALSENSING.,A..WO ND7NADS TOA N DSHEETD8F OURGFPSENSING.BLDCKALSO SHEETRD MASTER CONNECTIONDIAGRAM C URRENT S ENSOR C ONNECTIONS FOR(U SE RMS)9Instruction Leaflet IL29C714LEffective October 2012Master Connection Diagram Series C R-Frame Circuit Breaker with DIGITRIP RMS T rip UnitsEATON CORPORATION RD MASTER CONNECTION DIAGRAM3P OLE RD W I TH RMS U NIT -N EUTRAL P ROTECTEDC ONNECTIONS,B REAKERSAI SHUNT.I IIII II IWHTII I IvENDBREAKERCONNECTIONSCPARTIAL ONLY)MUST B EMARKED:II II IIISHUNT TRIPWHT (+) 15RD MASTER CONNECTION DIAGRAM4P OLE RD W I TH RMS U NIT N EUTRAL P ROTECTEDCONNECTIONS B REAKERSTABCDSHUNT TRIPI I II II --------------I II II I II310,510,810,910I750,AND 1050II IICIRCUITAB C DBOTTOMNO.OFCAT.NO.SWITCHESA1RD MASTER CONNECTION DIAGRAMA LARM (S IGNAL)L OCKOUT S WITCH CONNECTIONSB8B12bPREFERREDFIG.AFIG.BB4B5A 7A 8A9A11A12bFIG.CFIG.DA l l A12b FIG.ETHE MAXIMUMNUMBER ACCESSORIES THAT MAY BE INSTALLED IN A N Y ONE CIRCUIT BREAKER I S LIMITED BY THE NUMBER OFPHYSICAL POSITIONS.B6A7A 8S TPREFERREDWHTFIG.AWHTFIG.CA9A10STA5A 6>-STTHE MAXIMUM NUMBER O F TVO SHUNT TRIPS MAY BE INSTALLED I N ANY O N E CIRCUIT BREAKER,RD MASTER CONNECTION DIAGRAMS HUNT T RIP C ONNECTIONSPREFERREDFIG.A F I G.A9A1FIG,BA5A6FIG.NOTE:THE MAXIMUM NUMBER OF TWO UVRS MAYBE INSTALLED I N ANY ONE CIRCUITBREAKER.RDMASTER CONNECTION DIAGRAMR ELEASE C ONNECTIONSRD MASTER CONNECTION DIAGRAMLow E NERGY S H U NTA7AS PREFERRED FIG.AA9A10F IG .BA3A4LEST FIG.CA5A6LESTTHE MAXIMUMNJMBER OF ACCESSORIES THAT MAY BEINSTALLEDANY ONECIRCUIT BREAKER ISBYNUMBERPOSITIONS.I T I CLOSEDI r--------II RD FRAMEIIMOTORI OPERATORIIUIIIIIIII I II IX AUX.R E L A Y LEGEND1TRANSFORMER MAY BEBREAKER AUX.Y RELAY b BREAKER SWITCHRE Q UIRED L Y-O NAND MOTOR CONTACTS SHOWN I N OPEN RESET I S-MOTOR OPERATOR TERMINAL BLOCKRD MASTER CONNECTION DIAGRAMM OTOR O PERATOR C ONNECTIONSALL RD BREAKERS EQUIPPED WITH DIGITRIP RMS500,600,700,800,510,610,810,910,750,AND1050TRIP UNITS WITH G F P WILL TRIP NEAR INSTANTANEOUSLY(0.04-0.12 SEC.)REGARDLESS OF THE TIME BAND SETTING-IF DUWNSTREAM INTERLOCK WIRING I S NOT EMPLOYEDA JUMPER I S NOT ADDED BETWEEN CONTROL TERMINALS C4AND WITH THE JUMPER ADDED,THE BREAKER WILL RESPOND TOTHE PRE-SET TIME DELAY SETTING.CONSIDER ADDING THIS JUMPERFOR ALL INSTALLATIONS WITH GFP ON THE MAIN BREAKER ONLY.INSTALLATIONS WITH MULTIPLE LEVELS OF GFP,SEE SHEET2.ALL RD BREAKERS EQUIPPED WITH RMS500,600,700, 800,510,610, 810, 910,750AND1050TRIP UNITS EQUIPPED WITH AN ADJUSTABLE: SHORT TIMEDELAY SETTING WILL TRIP NEAR INSTANTANEOUSLY(0.04-0.12REGARDLESS OF THE TIME BAND SETTING-IF DOWNSTREAM INTERLOCK WIRING I S EMPLOYED AND/OR A JUMPER I S NOT ADDED BETWEENCONTROL TERMINALS D9WITH THE JUMPER ADDED,THE BREAKERWILL RESPOND TO THE PRE-SET TIME DELAY SETTING.FOR SELECTIVE CDORDINATIDN,INTERLOCK WIRING BE EMPLOYED.SEE SHEET3,RD-BREAKERS HAVE BEEN DESIGNED FOR MAXIMUM PROTECTION,COMMUNCATIONS AND ACCESSORY UTILIZATION.THIS REASON ALL LEADS I N THE SECONDARY CONTROL BLOCKS MAY NOT BE USED BY A CUSTOMER FOR A PARTICULAR APPLICATION.WARNINGBREAKER AUTOMATIC OPEN AND CLOSE OPERATIONS BY INCOMCDMMUNICATION SIGNALS(V I A TERMINALS AND UNDERSYSTEM OPERATING OR MAINTENANCE PERIODS CAUSESEVERE INJURY DEATH,INSTALL APPROPRIATEPERMISSIVE MEANS(SEE SHEETAVOID UNDESIRED CLDSING DURING MAINTENANCEOPERATIONS AND PRDVIDE ADEQUATE EQUIPMENT WARNINGSFOR NORMAL PERIODS.RD MASTER CONNECTION DIAGRAMG E N E R A L N OTESJUMPER MUST BE ADDED ON EACH DOWN STREAM BREAKERWHERE D E L A Y PRE -SET REQUIRED.SEE ALSO NOTE '1SHEET '17.AND RUN SEPARATEFROM POWERCABLESPERA MAXIMUM DISTANCE BETWEEN THE FIRST AND LAST ZONE IS 250FEETAOF20MAYCONNECTEDINPARALLEL ZONE3EMPLOYEDSELF -INTERLOCK.A MAXIMUM OF20MAY BE CONNECTEDINSIGNAL DIODES TYPE1ORAS SHOWN IN 3ALTERNATE.A MAXIMUM OF 5BREAKERS M A Y BECONNECTEDZONE 3WHEN EMPLOYED SELF -INTERLOCK.ZONECONSIDERATIONS MUST6B EO N(D U A L S O U R C E )O RDISTRIBUTION SYSTEMS TOSEQUENCES.C4OUTPUTC O M M O NRD MASTER CONNECTION DIAGRAM T Y P I C A L G ROUND F AULT Z ONE I NTERLOCKINGC ONNECTIONS FOR R ADIALD ISTRIBUTION S YSTEM(U SE W I TH RMS E Q UIPPED W I T H G ROUND F UNCTION )18ቧቢJUMPER MUST BE ADDED ON EACH D O W N STREAM BREAKERNOTE2SHEET17.A N D R U N S E P A R A T E FROMOR COPPER WIRE6REQUIRED PER UL-1053A MAXIMUM DISTANCE BETWEENTHE FIRST AND LAST ZONE IS 250FEET.A MAXIMUM OF20MAY BE CONNECTEDIN PARALLEL ZONEA MAXIMUM OF20BREAKERSEMPLOYED SELF-INTERLOCKSIGNAL DIODES OR EQUIVALENTA MAXIMUM OF5BREAKERSMAY CONNECTEDIN PARALLEL IN ZONE3SELF-INTERLOCK.OUTPUTCOMMONRD MASTER CONNECTION DIAGRAMSC ONNECTIONS FOR R ADIALD ISTRIBUTION S YSTEM(U SE WITH DIGITRIP RMSE Q UIPPED WITH S H O RT D ELAYF UNCTION)20 EATON CORPORATION 21EATON CORPORATION 22EATON CORPORATION V VVASELECTRIC OPERATOR FUNCTIONREQUIRED 700,800,810,910,ANDREMOTELY CLOSEVIA INCOM.IFOPERATORNOT SUPPLIED,RED ANDSEE S H E E T 23.BLUEBE PRESENTBUTCONNECTED.PT MODULE ISNOTTYPERD MASTER CONNECTIONDIAGRAMC ONNECTIONS FORUSERMS 700,800,810,910,750,AND 10504ICLOSE(O P T IONAL)(OPTIONALSUPPLYVOLTAGEI III IX--ON RELAY LEGENDa BREAKER AUX1TRANSFORMER MAY BE Y RELAY b BREAKERREQUIRED MEET SUPPLY REQUIRMENTS-ON2R A N D OP E R A T O RSHOWN IN OPEN RESET I S-MOTOR OPERATOR TERMINAL BLOCKLCS-LATCH CHECK TERMINAL BLOCKRD MASTER CONNECTIONDIAGRAMM OTOR O PERATOR C ONNECTIONSAUX23EATON CORPORATION 24 EATON CORPORATION 25EATON CORPORATIONRI1PULSED 'ON'VIA INCBREAKERO P E R A T O R I S USED)BOTTOMBY SIGNAL(VIAORINSTALLMEANS(SEEANDTYPE COMMUNICATION USEOFORC O ND U C T O RSSUPPLED810, 910,ASSTANDARD700,910,R D MASTER CONNECTION DIAGRAM RD BREAKER W I T H DIGITRIP GROUND FAULT AND INCOMASON910,750,IFIS R EDLEADSBUTSUPPLEDANDINCOM COMMUNICATION PERSONALEQUIPMENTHIGHAUTOMATIC PERMISSIVEMAINTENANCE OPERATIONS OPERATIONCONNECTIONS26 EATON CORPORATION 27EATON CORPORATION Notes:28EATON CORPORATION Eaton Corporation Electrical Sector1111 Superior Ave. Cleveland, OH 44114United States877-ETN-CARE (877-386-2273) © 2011 Eaton CorporationAll Rights ReservedPrinted in USAPublication No. IL29C714L / TBG001037 Part No. 6615C95H12October 2012Eaton is a registered trademark of Eaton Corporation.All other trademarks are property of their respective owners.The instructions for installation, testing, maintenance, or repair herein are provided for the use of the product in general commercial applications and may not be appropriate for use in nuclear applica-tions. Additional instructions may be available upon specific request to replace, amend, or supplement these instructions to qualify them for use with the product in safety-related applications in a nuclear facility.This Instruction Leaflet is published solely for information purposes and should not be considered all-inclusive. If further information is required, you should consult an authorized Eaton sales representa-tive.The sale of the product shown in this literature is subject to the terms and conditions outlined in appropriate Eaton selling policies or other contractual agreement between the parties. This literature is not intended to and does not enlarge or add to any such contract. The sole source governing the rights and remedies of any purchaser of this equipment is the contract between the purchaser and Eaton. NO WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, OR WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE, ARE MADE REGARDING THE INFORMATION, RECOMMENDATIONS, AND DESCRIPTIONS CONTAINED HEREIN.In no event will Eaton be responsible to the purchaser or user in contract, in tort (including negligence), strict liability or otherwise for any special, indirect, incidental or consequential damage or loss whatsoever, including but not limited to damage or loss of use of equipment, plant or power system, cost of capital, loss of power, additional expenses in the use of existing power facilities, or claims against the purchaser or user by its customers resulting from the use of the information, recommendations and description contained herein.。
柯蒂斯电控资料
科蒂斯CURTIS系列电动汽车电机控制系统系列产品技术资料由于是进口产品!中文资料较少!这是我花费了不少时间搜集整理出来的!型号:1204/1205:串励电机速度控制器类型:电压:24-48V;电流:175-400A适用范围:科蒂斯1204/1205/1209型串励电机速度控制器是多种工业电动车辆的理想选择。
广泛应用于电动搬运车、电动装载车、物料搬运车、高尔夫球车以及其他小型串励机设备应用场合。
型号:1207A:串励电机速度控制器(CURTIS/PMC1270A)类型:额定电流:250A/300A;额定电压:24V。
可编程适用范围:可编程科蒂斯1207A型串励电机速度控制器是小型电动车辆的理想选择。
广泛应用于电动托盘车、堆垛车、电动搬运车、清扫车以及其他小型串励和复励电机设备应用场合。
型号:科蒂斯1209B:串励电机速度控制器类型:电压:36-48V/48-72V电流:400-450A适用范围:是多种工业电动车辆的理想选择。
广泛应用于电动搬运车、电动装载车、物料搬运车、高尔夫球车以及其他小型串励电机设备应用场合。
类型:科蒂斯1210:永磁电机速度控制器:类型:符合欧洲及美国标准,可编程。
电压:24V;电流:45A/70A适用范围:科蒂斯1210型永磁电机速度控制器适用于3-4轮的电动休闲车及代步车及清扫车等小型工业车辆。
型号:科蒂斯1214/1215/1219类型:可编程额定电压:48V额定电流:250A/300A/400A/500A/600A;适用范围:是电动车辆的理想选择。
广泛应用于电动托盘车、堆垛车、电动搬运车、清扫车以及其他小型串励和复励电机设备应用场合。
串励电机速度控制器。
型号:科蒂斯1221B串励电机速度控制器类型:24-36 V, 600 A;36-48 V, 550 A;48-72 V, 500 A适用范围:是多种工业电动车辆的理想选择。
广泛应用于电动搬运车、电动装载车、物料搬运车、高尔夫球车以及其他小型串励电机设备应用场合。
LS1手动永磁起重器产品说明书
浙江力帅磁电科技有限公司永磁吊装器使用说明书合格证使用前必须事先熟读本使用说明书地址:浙江省缙云县壶镇贤母西路249号邮编:321404使用目录一.产品主要用途和特点 (1)二. 安全防范措施 (1)三. 产品操作与建议 (5)四. 产品主要结构和参数 (9)五. 产品型号的选择 (11)六. 吸盘的维护和检测 (12)七. 合格证 (15)敬告:请在详细阅读本使用说明书后方可使用本产品,若有不明确处,请来电来函,共同商讨形成共识后再使用本产品。
一. 产品主要用途和特点LS1系列强力永磁起重器(下文中简称吸盘)适用于搬运钢板、铁块及圆钢等导磁材料。
其特点有:1.体积小、重量轻、操作方便。
2.永久性磁铁(钕铁硼)制造、无需电力,避免断电危险及连接电源的麻烦。
3.设计具有3倍的安全系数(静测试)、磁力强大、使用时安全性更高、效能更大。
从而改进装卸搬运作业的工作条件,已广泛的运用于工厂、码头、仓库和交通运输行业中。
二. 安全防范措施使用起重设备期间都存在着潜在的危险,尤其是对设备的错误操作和维护的缺失更会引发危险。
为了避免危险事故和人员伤亡,操作、检查和维护每个步骤都必须要做好充分的安全防范措施。
1. 以下一系列规则能够防止危险事故的发生:1.1在没有阅读使用说明书之前,请不要尝试去操作使用吸盘。
1.2处理好跟此次起吊有关的方方面面,包括吸盘、工件以及你周边的环境等等。
1.3严禁在起重工件底下站人并保持一定的安全距离。
1.4不要用吸盘去吊人、支撑人甚至是运输人员。
1.5在离开之前,请确保把未卸下的物料卸下。
1.6每只吸盘每次只能吊一个工件。
1.7确保支撑整个工作的设备(例如行车、绳索、链条、钩子)与起重器的额定起重重量相对应。
1.8确保工件的重量在额定起重范围内,尺寸也要在本说明书规定的范围内,请按照本说明书第五章规定使用。
1.9 在每次起吊开始之前,告诉你身边的人要注意。
2. 避免降低吸盘起吊能力的措施:2.1确保吸盘的底面和工件接触的表面是干净、平坦、光滑。
IAL IUL IEL LEL磁路保护器参数表及特点介绍说明书
IAL/CEL/LEL Series• 147• 148• 150 • 154• 157• 159 • 163 • 165Introduction Poles Handles Configurations Operating Characteristics Delay Curves SpecificationsDecision TablesINTRODUCTIONIAL/IUL/IEL/LEL magnetic circuit protectors provide low-cost power switching, reliable circuit protection and accurate circuit control for equipment in the international marketplace.IAL models are for those applications where the unit’s inherent attributes are desired, but compliance with the various standards is not required.IUL models have been tested and approved in accordance with UL 1077 requirements for UL recognition.IEL/LEL models are VDE approved to VDE 0660, part 101. They meet IEC spacing requirements, mandatory for equipment which must comply with IEC specifications 601 and 950, and VDE specifications 0804 and 0805. In addition, the IEL models are UL recognized to UL 1077 as supplementary protectors and the LEL models are UL listed under the conditions of UL 489. Both are CSA certified and CCC Approved. The IEL is CSA certified as a supplementary protector per CSA C22.2–No. 235.The CEL model has achieved two new enhancements, including a single pole, 125 amp rating with TÜV approval, and a parallel 4-pole version with 400 amp rating.Airpax™ IAL/CEL/LEL circuit protectors are available in a wide variety of configurations, including series, series with auxiliary switch, shunt and relay with choice of delays and ratings in DC and/or 50/60Hz or 400Hz versions. Single or multi-pole versions are available with a variety of pole arrangements to meet your specifications. Please see the appropriate product specification table for ratings and limitations.Screw TerminalSingle PoleClip Terminal Bullet TerminalNotes:Tolerance ± .015 [.39] unless noted.Dimensions in brackets [ ] are millimeters.A T erminal protrusion dimensions are referenced from back of mountingpanel.B E ach screw terminal is supplied with a 10-32x.312 [7.92] or M5 x 8mmscrew, flatwasher and external tooth lockwasher.C S tud terminals are supplied with a flatwasher, external tooth lockwasherand a 10-32 or M5 hex nut (<=70A) (<=50A for LEL),1/4-20 or M6 hex nut(>70A)(>50A for LEL).Mounting DetailNote: Each outer terminal is supplied with af latwasher, tooth lockwasher and a hex nut.Bullet terminal receptacle should be .312 ± .001diameter hole not less than .250 depth. ContactSensata for other bullet sizes.Panel Mounting DetailTolerance ±.005 [.13] unless noted.Note:A Terminal protrusion dimensions are referenced from back of mounting panel.B Each screw terminal is supplied with a 10-32x.312 [7.92] or M5 x 8mm screw, flatwasher and external tooth lockwasher.C Stud terminals are supplied with a flatwasher, external tooth lockwasher and a 10-32 or M5 hex nut (<=70A), 1/4 -20 or M6 hex nut (>70A).Two PoleMAX.IELH11IEL11Note:Tolerance ± .015 [.38] unless noted.Dimensions in brackets [ ] are millimeters.[3.96]4XTwo Pole*Two Pole*Note:Each outer terminal is supplied with a flatwasher, tooth lockwasher and a hex nut.Panel Mounting DetailTolerance ±.005 [.13] unless noted.Multi-pole units are combined in an assembly with the trip mechanisms internally coupled. A fault in any protected circuit opens all poles simultaneously. Applications include use in polyphase circuits, single-phase three-wire systems, or in two or more related but electrically isolated circuits. A mix of delays, ratings and configurations are offered. The auxiliary switch is offered with either gold or silver contacts and is available when a series construction pole is specified.Two Pole UnitsAn assembly consisting of two single pole units, having their trip mechanisms internally coupled, is available with either a single toggle handle or with a handle per pole. Please see decision one of the part number decision tables. Individual poles may vary in ratings, delays and internal configurations. If the poles are of series construction, an auxiliary switch may be included in either or both poles, allowing you to mix SELV and hazardous voltages.MULTI-POLE CIRCUIT PROTECTORS[57.53]2.265MAX.Three Pole and Four Pole UnitsThe three pole structure consists of three single pole units assembled with an internal mechanical interlock which actuates all units simultaneously. The units are available with either a single toggle handle or with a handle per pole. Units with four pole construction operate with a minimum of two center toggle handles or with a handle per pole. Please see decision one of the part number decision tables. Mixing of delays, ratings and configurations is available in each individual pole. The auxiliary switch is offered in any series trip pole.Breaker poles are numbered consecutively when viewed from the terminal side, with the ON position up, starting with pole #1 on the left side and proceeding to the right.Three Pole IEL111MAX.[57.53]2.265Mounting Detail*[19.05].750[19.05].750[57.91]2.280MAX.[76.58]3.015Four Pole IEL1111[19.05].750[19.05].750[19.05].750[38.86]1.530Mounting Detail*[19.05].750[19.05].750Note:Tolerance ± .015 [.39] unless noted. Dimensions in brackets [ ] are millimeters.*See Single Pole Mounting Detail for Hole Sizes and Locations.Three Pole IELH111MAX.[76.58]3.015[19.05].750[19.05].750[19.05].750[76.96]3.030Mounting Detail*Four Pole IELH1111Mounting Detail*BX - FLAT ROCKER HANDLEThe innovative new design of our IAL/CEL/LEL BX Style circuit protectors features a flat rocker that will satisfy your aesthetic needs while guarding against accidentalactuation, providing the highest degree of circuit protection and quality. Only Airpax offers this new standard in user interface. Available on a variety of versions with a full range of agency approvals, the IEL BX style circuit protectors meet or exceed all current performance specifications, including interrupting capacities up to 50,000 amperes.1.239[31.47].387 REF.[9.84].768[19.49]1.859[47.22]2.490 MAX.[63.25]2.173 MAX.[55.19].314[7.98]1.395[35.43].125[3.17]6-32 THD. MOUNTING M3 ISO THD. OPTIONAL1.660[42.16].750 MAX.[19.05]OPTIONAL GUARD(SEE DETAIL ìCî)SINGLE POLE1.660[42.16].750[19.05]1.260[32.00].200[5.08]2X ÿ.156[3.96]Panel Mounting DetailMounting Detail Tolerance: ±.005 [.13] unless notedON ION IACTUATION ACCESS(SEE NOTE)DETAIL "A"ON I O OF FON IO OF FON I O OF FON IOF FOHANDLEPOSITION "OFF"GUARD WITH NO ACTUATE OFF FEATURE(SIXTH DECISION, X)HANDLEPOSITION "ON"GUARD WITH NO ACTUATE OFF FEATURE(SIXTH DECISION, X)PU SH TO RE SE TNOTE: ACCESS IS LIMITED TO A DEVICE SMALLER THAN THE UNDERWRITERS LABORATORY "ARTICULATED PROBE" DEFINED IN UL-489 FIG. 11.1.7.2.1.HANDLEPOSITION "OFF"WITH GUARD(SIXTH DECISION, G)HANDLEPOSITION "ON"WITH GUARD(SIXTH DECISION, G)HANDLEPOSITION "OFF"WITHOUT GUARD HANDLEPOSITION "ON"WITHOUT GUARDPU SH TO RE SE TPanel Mounting DetailTolerance ±.005 [.13] unless noted.I A L S e r i e sThe Airpax™ LELHP/CELHP high current magnetic circuit protector compliments our entire series of LEL circuit protectors. Its unique, parallel current sensing design provides precise current overload protection and reliability in the compact size of a two pole LEL. The unit is ideal for high power DC applications such as drive motor systems and telecommunication power systems.LEL is available in series and series with auxiliary switch configurations with a choice of delays for DC ratings of 125, 150, 175 and 200 amperes. The CEL has been enhanced to include these same ratings plus a 4-pole, parallel 400 amp rating for UL489A. The LELHP is UL listed under the conditions of UL489 and CSA certified. The CELHP is UL listed under the conditions of UL489A. Mid-trip handle indication, voltage trip and remote operator options complete the LELHP/CELHP circuit breaker series. Please see the individual product tables for approved ratings.LELHP/CELHP CIRCUIT PROTECTORSTwo Pole Three Pole Four PoleThe rocker style is available in one to four poles. Choose either vertical or horizontal mounting with ON-OFF, international markings or a combination of both.Five front panel enhancing colors including black, white, red, grey and orange are available.Note:A Terminal protrusion dimensions are referenced from back of mounting panel.Single PolePanel Mounting Detail* Single,Two & Three PoleFour Pole***Mounting detail tolerance ±.005 [.13] Unless noted.**See single mounting detail for hole sizes and locations.(Optional handle may be in Pole 2 instead of Pole 1.)IALX/IULX/IELX ROCKER HANDLESeries TripThe most popular configuration for magneticprotectors is the series trip where the sensing coil and contacts are in series with the load being protected. The handle position conveniently indicates circuit status. In addition to providing conventional overcurrent protection, it’s simultaneously used as an on-off switch.Shunt TripThe shunt trip is designed for controlling two separate loads with one assembly. The control is established by providing overload protection for the critical load. When the current through this load becomes excessive and reaches the trip point, the protector will open and remove power from both loads simultaneously. The total current rating of both loads must not exceed the maximum contact rating.Dual CoilBy combining two electrically independent coils on a common magnetic circuit, it is possible to provide contact opening when either an over-current or trip voltage is applied to the respective coils. One coil will be a current trip coil with standard specifications. The second, or dual coil, can be used to provide a control function permitting contact opening from a remote interlock or other transducer functions. Standard coils are 6, 12, 24, 48, 120 and 240 volts. Tripping is instantaneous and must be removed (usually self-interrupting) after trip.Auxiliary Switch (Applies to Series Trip Only)This is furnished as an integral part of a series pole in single or multi-pole assemblies. Isolated electrically from the protector’s circuit, the switch works in unison with the power contacts and provides indication at a remote location of the protector’s on-off status.Auxiliary switch contacts actuate simultaneously with the main breaker contacts, and will open regardless of whether the breaker contacts are opened manually or electrically. For auxiliary switch ratings below 6Vac or 5Vdc, an auxiliary switch with gold contacts, designated as REG is available. Gold contacts are not recommended for load current above 100 milliamps.SWITCH ONLYSERIES1.940[49.28].281[7.13]Dimension B(See Table)Dimension A(See Table)1.290[32.77].648[16.46]1.055[26.80]NCNOCBREAKER IN OFF POSITION1.26[32.00].278[7.05]1.940[49.28]2.640 MAX.[67.06](SEE NOTE A).795[20.19].660 ±.045[16.76] ±1.14]1.266[32.16].971[24.66].676[17.17]Dimension B(See Table)-IREC4, -IREG4.260[6.60].110[2.79]2.454 MAX.[64.52](SEE NOTE A)2.438 MAX.[64.52](SEE NOTE A)-IREC5.250[6.35].187[4.75][22.454 MAX.[64.52](SEE NOTE A)DUAL COILSHUNTSpacing for VDE SwitchSeries with Auxiliary Switch[17.17].676[24.66].971[32.16]1.266Note: Each outer terminal is supplied with a flatwasher,tooth lockwasher and a hex nut.Note:A T erminal protrusion dimensions are referenced from back of mountingpanel.B E ach screw terminal is supplied with a 10-32x.312[7.92] or M5 x 8mmscrew, flatwasher and external tooth lockwasher.C S tud terminals are supplied with a flatwasher, external tooth lockwasher and a 10-32 or M5 hex nut (<=70A), 1/4-20 or M6 hex nut (>70A).Series and Switch Only Shunt and Dual CoilCONFIGURATIONSSTUD TERMINAL TYPESScrew Stud Thread Dimension “A”Dimension “B”M6.510 ± .045[12.95 ± 1.14].652 ± .035 [16.56 ± 0.89]1/4 -20.545 ± .045[13.84 ± 1.14].687 ± .035 [17.45 ± 0.89]M5.510 ± .045[12.95 ± 1.14].652 ± .035 [16.56 ± 0.89]10-32.545 ± .045[13.84 ± 1.14].687 ± .035[17.45 ± 0.89]IALSeriesRelay TripThis permits the overload sensing coil to be placed in a circuit which is electrically isolated from the trip contacts. The coil may be actuated by sensors monitoring pressure, flow, temperature, speed, etc. Other typical applications include crowbar, interlock and emergency/rapid shutdown circuitry. Trip may be accomplished by voltage or current, which must be removed after trip.Voltage TripSometimes called “dump circuits” or “panic trip circuits,” these units make it possible to open main power contacts with lower power inputs from one or more sources. This configuration is becoming increasingly more important for sensitive circuitry and denser packaging in automation systems. Available in series, shunt or relay configurations.[18.34].722[33.78]1.330[7.14].281[16.76±1.14].660±.045[49.28]1.940[67.06]2.640 MAX [20.19].795RELAY Relay and Dual CoilNotes:Tolerance ± .015 [.39] unless noted. Dimensions in brackets [ ] are millimeters.A T erminal protrusion dimensions are referenced from back of mounting panel.B E ach screw terminal is supplied with a 10-32x.312[7.92] or M5 x 8mm screw, flatwasher and external tooth lockwasher.C S tud terminals are supplied with a flatwasher, external tooth lockwasher and a 10-32 or M5 hex nut (<=70A), 1/4 -20 or M6 hex nut (>70A).YDUAL COILBarriers[69.60]2.740[17.02].670[27.89]1.098[65.02]2.560[29.13]1.147[18.31].721[65.02]2.560[29.13]1.147[18.31].721[.84].033[78.74]3.100[35.00]1.378[24.18].952[7.69].303[3.11].122[.84].033NOTE:THIS BARRIER CAN BE FLIPPED TO COVER EITHER POLE.PLEASE CONTACT FACTORY FOR SPECIFIC PART NUMBERFIG.4FIG.3FIG.2FIG.1CONFIGURATIONS (CONT.)BARRIER OPTIONSRating OptionStandardBarrier Optional BarrierIEL240/415 VAC Fig. 1Fig. 2, 3 & 4415 VAC (VDE)277/480 VAC1/4-20, M6 studs for AC 120/240 VAC multi-pole Fig. 2Fig. 3 & 4125VDC LELAll multi-pole 50/60 HzFig. 2Fig. 3 & 4All multi-pole 80 VDC, if opposite polarity Fig. 2Fig. 3 & 4125VDCFig. 2Fig. 3 & 4Note: Optional barrier available with factory assigned part number. Contact factory for assistance.In the optional auxiliary switch configuration, the switch allows an alarm or signal to be forwarded when the breaker trips and the handle moves to the middle position. The alarm can be disengaged by themanual actuation of the handle to the OFF position. Once the fault has been corrected, the circuit breaker can be reset to the ON position. The mid-trip option is available in one, two or three pole toggle handle packages and in either standard panel screw or snap-in mounting. Please see specification tables of specific product for available ratings.Snap-In MountingThe snap-in mounting adapter allows for simplified mounting of most IEL/LEL toggle handle products. Prior toshipment, the adapter is attached to the circuit breaker during our final product assembly, allowing you to securely snap the unit into a rectangular panel cut-out. This eliminates the need for panel mounting hardware and associated assembly costs.Available for units up to three poles, with or without an option handle guard.Note: Tolerance ± .015 [.39] unless noted.Dimensions in brackets [ ] are millimeters.Panel Mounting DetailTolerance ±.005 [.13] unless noted.OPERATING CHARACTERISTICS400Hz, DC, 50/60Hz Delay Curves (typ)A choice of delays is offered for DC, 50/60Hz, 400Hz, or combined DC/50/60Hz applications. Delays 49, 59, 69 and 79 provide fast-acting, instantaneous tripping and are often used to protect sensitive electronic equipment (not recommended where a known inrush exists). Delays 41, 51, 61 and 71 have a short delay for general purpose applications. Delays 42, 52, 62 and 72 are long enough for most transformers and capacitor loads. Delays 43, 53, 63 and 73 are extra long for special motor applications.Inrush Pulse TolerancePulse tolerance is defined as a single pulse of half sine wave peak current amplitude of 8 milliseconds duration that will not trip the circuit breaker.The table on page 171 provides a guide to determine if the inertia delay feature is required. Consult factory for further assistance.DELAY CURVES400Hz Delay Curves (typ)*Available only in IAL/IUL/IEL; not available in LEL.DC/50/60Hz Dual-frequency Delay Curves (typ)IAL/IUL/IEL/IDL/LEL SPECIFICATIONSGeneral notes:• All supplementary protectors are of the overcurrent (OC) type• T he family of protectors has been evaluated for end use application for use groups (UG) A, B, C and D• The terminals (FW) are suitable for factory wiring only (0)• T he maximum voltage ratings for which the protectors have been tested are shown in the chart• T he current is the amperage range that the protectors have been tested• T he tripping current (TC) for all of the protectors is either either “1” (in the range of 125% to 135% of ampere rating) or “2” (more than 135% of ampere rating)• T he overload rating (OL) – designates whether the protector has been tested for general use or motor starting applications.0 – tested at 1.5 times amp rating for general use1 – t ested at 6 times AC rating or 10 times DC rating for motor starting• T he short circuit current rating (SC) – The short circuit rating in amperes following a letter and number designating the test conditions and any calibration following the short circuit test is defined below:C – Indicates short circuit test was conducted with series overcurrent protection U – Indicates short circuit test was conducted without series overcurrent protection 1 – Indicates a recalibration was not conducted as part of the short circuit testing 2 – Indicates a recalibration was performed as part of the short circuit testing 3 – Indicates recalibration was performed along with the dielectric and voltage withstand for “Suitable for Further Use” ratingIAL/IUL/IEL DECISION TABLES The ordering code for IAL/IUL/IEL/LEL circuit protectors may be determined by following the decision steps in the appropriate part number decision table subsequent to this page.The coding given permits a self-assigning part number but with certain limitations.Special applications may require a factory assigned part number. Typical examples are units with mixed ratings, combinations of styles, or constructions not listed in the third decision table, etc. With these, it is suggested that order entry be by description and/or drawings, and a part number will be established. Additionally, it is standard policy to establish a factory-assigned part number whenever a descriptive drawing exists to provide cross reference, traceability and manufacturing control.When specifying a circuit breaker for AC motor start or high inrush applications, the peak amplitude and surge duration should be specified for factory assistance in rating selection.For example the code shown is the code for a single pole breaker with a series construction and auxiliary switch, designed for operation in a 50/60Hz circuit. It has a short time delay, rating of 20 amperes and a marked black handle, and is VDE approved.To determine the ordering number for your particular IAL/IUL/IEL unit, simply follow the steps shown. You may use this number to place an order or as a reference for further questions you may have.Notes:IEL, IELH and IELX circuit protectors are designedto meet 8mm creepage clearance requirements for installation Category 111, Pollution Degree 3, Case A as measured in IEC 664. Intended for use in equipment to comply with IEC 950, 601 and VDE 0804 & 0805.Second DecisionSingle poleTwo poleThree poleFour pole*11111111112Poles*Not available in toggle seal handle type.Consult factory for 5 and 6 pole IEL part number.Internal Con gurationThird Decision3* Only one auxiliary switch is normally supplied on two or threepole units. Switch is located in the right-hand pole (viewed fromterminal end) unless otherwise speci ed.1234IEL 1 - 1REC4- 61- 20.0 - 01 - V57Example:Fourth Decision4Frequency & DelaySwitch only400Hz short delay400Hz long delay400Hz motor start400Hz 150% instant tripDC short delayDC long delayDC motor startDC 125% instant trip50/60Hz short delay50/60Hz long delay50/60Hz motor start50/60Hz 125% instant tripDC/60Hz short delayDC/60Hz long delayDC/60Hz motor startDC/60 Hz 135% instant tripFor addition of inertial delay, add an ìFî to anydelay numeral.SW-41-42-43-49-51-52-53-59-61-62-63-69-71-72-73-79N ote: C CC Approval is pending.IALBX**IULBX***IELBX**IMLBXOne handle per unitOne handle per poleOne handle per unitpanel sealOne handle per unit,rocker, bracket mountingOne handle per unit,rocker, integral mountingOne handle per unitUL 1500One handle per poleUL 1500One handle per unitmid trip indicationOne handle per polemid trip indicationOne handle per unit,rocker, accidental-offprotectionOne handle per unit,mid trip indication, rocker,accidental-off protection*UL Recognized**UL Recognized, CSA Certi ed***UL Recognized, CSA Certi ed, VDE Approved*** I ML***I MLHSelect Type and TerminalFirst Decision1IAL**IUL***IELIALH**IULH***IELHIALN***IULNIALX**IULX***IELXIALZX**IULZX***IELZX*I DL*I DLHType TerminalStandard screw terminal,no designation requiredStud terminalsClip terminalsBullet terminalsKCBThe shaded areas denote VDE and CCC(if applicable) Approval options. T his approvalrequires the addition of a V at the end of thepart number. The V will be added to any partnumber formed entirely from shaded decisions.If non-shaded areas are selected, the unit will notbe VDE or CCC Approved, but other approvalsstill apply.V = VDE and CCC ApprovedDescriptionN ote: C CC Approval is pending.-0-1-1REC4-1REC5-1REG4-1RS4-1RLS4-1RS5-3-4Switch only (50, 70 or 100 amp switch)SeriesSeries with auxiliary switch*.110 quick connectSeries with auxiliary switch*.187 quick connectSeries with auxiliary switch.110 quick connectSeries with alarm switch,electrical trip, .110 quick connectterminalsSeries with alarm switch,electrical trip, .110 quick connectterminals (mid-trip only)Series with alarm switch,electrical trip, .187 quick connectterminalsShuntRelay (not available in IEL/IELX)This approval requires the addition of a C at the endof the part number. T he unit will not be VDE Approved.C = CCC ApprovedLEL DECISION TABLESCEL DECISION TABLESLELHP DECISION TABLES。
海康威视GPT-12000系列电源安全分析仪说明书
CONTINUITY TEST
Output-Current Ohmmeter Measurement Range
Ohmmeter Measurement Resolution Ohmmeter Measurement Accuracy Window Comparator Method TIMER (Test Time)
Function Model
Output Capacity
AC
DC
IR
GB Continuity Rear Output
GPT-12001
200VA
GPT-12002
200VA
GPT-12003
200VA
GPT-12004
200VA
7” LCD
SPECIFICATIONS
AC WITHSTANDING Output-Voltage Range Output-Voltage Resolution Output-Voltage Accuracy Maximum Rated Load Maximum Rated Current Output-Voltage Waveform Output-Voltage Frequency Voltage Regulation Voltmeter Accuracy Current Measurement Range Current Best Resolution Current Measurement Accuracy Window Comparator Method ARC Detect RAMP UP (Rise Time) RAMP DOWN (Fall Time) TIMER (Test Time) WAIT TIME GND DC WITHSTANDING Output-Voltage Range Output-Voltage Resolution Output-Voltage Accuracy Maximum Rated Load Maximum Rated Current Voltage Regulation Voltmeter Accuracy Current Measurement Range Current Best Resolution Current Measurement Accuracy Window Comparator Method ARC Detect RAMP UP (Rise Time) RAMP DOWN (Fall Time) TIMER (Test Time) WAIT TIME GND
880 870螺纹钢管诊断仪说明书
Installation & Instruction Manual
Safety Information
Important – Please Read Before Installation
J Flow Controls 880 / 870 Series Diaphragm Actuator instructions contain Danger, Warning and Caution labels, where necessary, to alert you to safety related or other important information. Read the instructions carefully before installing and maintaining your control valve. Danger and Warning hazards are related to personal injury. Caution hazards involve equipment or property damage. Operation of damaged equipment can, under certain operational conditions, result in degraded process system performance that can read to injury or death. Total compliance with all Danger, Warning and Caution notices is required for safe operation. The safety terms Danger, Warning, Caution and Note have used in these instructions to highlight particular dangers and/or to provide additional information on aspects that may not be readily apparent.
Leica_TS15用户手册
用户手册
版本 3.1 中文
简介
购买 祝贺您购买了 Leica TS15。 本手册包括了重要的安全指南,可指导您安全地安装并使用仪器。 详情请参见 "6 安全指 南 "。 请您在使用本产品之前仔细阅读用户手册。 仪器标识 仪器的型号和序列号标注在仪器标签上。 请将仪器型号和序列号填写在下面。当您需要与经销商或 Leica Geosystems 授权的维修部 门联系时,将会用到这些信息。 类型: 序列号: 符号 _______________ _______________
7.9 7.10
7.11 7.12 7.13 8 索引
软件许可协议
TS15, 目录
5
1
1.1
系统组成
系统描述
系统组成
LG O
003962_001
TS15
CS15
一般性描述 主要组件
TS15 共同术语,描述全站仪 Leica Viva Series。 组件 TS15 仪器 描述 • • • • 一款可进行测量,计算以及采集数据的全站仪。 包含多种不同精度级别的仪器。 集成 GNSSGNSS 系统,可构成 SmartStation。 结合多功能的 CS10/CS15 外业手簿实现遥控测量。
本手册中的符号含义: 类型 描述 表示一个可能遇到的危险情形,如果不加以避免,将导致严重伤害 甚至死亡事故。 表示潜在的或操作不当所致的危险情况,如果不加以避免,将造成 伤亡或严重损害。 表示潜在的或操作不当所致的危险情况,如果不加以避免,将造成 伤亡或严重损害 表示潜在的或操作不当所导致的危害,如果不加以避免,将导致轻 微的人身伤害或明显的设备、经济损失和环境的损害。 表示在实际使用中必须注意的重要章节,以便能够正确、有效地使 用该仪器。
LT-S-(L) 技术手册说明书
Contents1.Overview (3)2.Product Specification (4)2.1Nomenclature (4)2.2Product Line (4)2.3Compressor specification table (4)2.4Operating range graph (6)3.Construction & Functions (8)3.1Design Features (8)3.2Capacity modulation system (8)3.2.1Step type capacity modulation system (10)3.2.2Stepless type capacity modulation system (14)3.2.3The Location of the Solenoid Valves (19)4.Lubricant (21)4.1Lubricant Specification (21)4.2The Replacement of Lubricant (22)4.3.1Oil Change Schedule (22)4.3.2Pre-cautions for changing oil (22)5.System Application (24)5.1Piping Design (24)5.1.1Suction and Discharge Piping Layout (24)5.1.2Economizer Piping Layout (26)5.1.3Minimum pressure valve (26)5.1.4Liquid Line Filter Dryer (27)5.1.5Sight Glass with Moisture Indicator (27)5.2Oil Line (28)5.2.1Oil Supply (28)5.2.2Lubrication and Capacity Control Modulation (28)5.2.3Compressor chamber injection system (28)5.2.4Protection in Oil Circuit (29)1)Oil temperature (29)2)Oil filter (30)3)Oil pressure differential (31)4)Oil level protection (31)5.2.5Oil cooling system (31)1)Air cooling type (33)2)Water cooling type (33)3)Refrigerant oil cooling (34)5.3Motor Liquid Injection Cooling (34)5.4Economizer System (35)5.4.1Economizer System with Sub Cooler (35)5.4.2Economizer System with Flash Type Subcooler (36)5.5Recommended System Layout (38)Figure 5-14. High Temperature Heat Pump Recommend System Layout (38)6.Electrical Design (39)6.1Electrical parameters and design (39)6.1.1Y-Δ Start (39)6.1.2Power requirements (40)6.1.3MCC&LRA (41)pressor Installation (45)7.1Open compressor wooden crate (45)7.2Compressor Lifting (45)7.3Compressor installation (46)8.Operation and Maintenance (48)8.1Compressor commissioning check (48)1.1.1Check list before Start (48)8.1.2Check list during operation (49)8.2rouble shooting table (50)9.Dimensions (53)10.Accessories (60)10.1Accessory List (60)10.2Accessory for gas refrigerant line (61)10.2.1Shut-off valve (61)10.2.2Tube (62)10.2.3Check valve (64)10.2.4Minimum pressure valve (66)10.3Oil line accessory (68)10.3.1Oil flow switch (68)10.3.2Oil Line Solenoid Valve (70)10.3.3Oil Pressure Differential Switch (70)10.4Electrical Accessory (71)10.4.1INT69 HBY Diagnose Protection module (71)10.4.2300Woil heater (74)10.5Other accessories (77)10.5.1Cushion (77)1.OverviewFor conventional single-stage screw compressors, Its evaporation temperature can only reach -40~-50°C during freezing application. If you want to break this application limitation, it is required to use two-stage compressor or cascade system. Meanwhile, the working condition of high pressure ratio brings problems to the traditional single-stage compressors during compression process, such as excessive gas leakage and high exhaust temperature etc., which leads to low efficiency and poor reliability when it is working is such harsh conditions.The compound two-stage compressor well solves above problems. Compared with the two-stage compressors or cascade system, the compund two-stage compressors occupy less space and the system is easy to control, so it's more efficiency and reliable.LT Series compound two-stage compressor’s evaporation temperature can be as low as -60~-65°C , Its full load evaporating temperature can be -25°C, LT-S-L Series compound two-stage low temperature compressor is based on the LT-S series which modified the internal structure and optimized the motor matching to increase the compressor full-load evaporation temperature to -10 °C, So that LT-S-L series can meet the requirements of industrial refrigeration、quick freezing tunnel and freezing library without pre-coolingFor above reasons, Therefore The Shanghai Hanbell Precise Machinery Co., Ltd. developed the LT series high temperature compressors. High efficiency and reliability under big pressure differential and compression ratio working condition is the main demand in designing. It is a elitist product which accumulates Shanghai Hanbell's rich technology and extensive application experience. It can be widely used in many industries such as high temperature hot water, central heating and so on.2. Product Specification2.1 NomenclatureTable 2-1.LT series low temperature compressor nomenclature 2.2 Product LineTable 2-2.LT low temperature series product specification★2.3 Compressor specification tableTable 2-3.LT series compressor specification2.4Operating range graph图2-1. R22运行范围图图2-2.R404A运行范围图3.Construction & Functions3.1Design Features1)Starting loadStarting with light load; its starting load is similar to ordinary single stage compressor, so as to avoid greater impact on power grid.2)Motor cooling channelExcellent motor cooling channel design which ensures the high efficiency of the compressor, while realizing the reliable cooling of the motor, so that the compressor can operate in a very wide range, and a more extensive scope of application.3)integrated design of system partsPre-installed medium pressure check valves, shut off valves and economizer filters that ensure reliable protection of compressors and simplify customer system configuration.4)Motor temperature visualizationThe embedded temperature sensor of motor, PT100, PT1000 and NTC, are optional, which can directly read the motor temperature to control the motor temperature.3.2Capacity modulation systemLT series screw compressor is equipped with 3/4 step capacity modulation system or continuous (stepless) capacity modulation system.Both of the two capacity modulation systems are composed of slide valve, piston rod, piston cylinder and piston. As shown in Figure 3-1 below.When the spool is fully in contact with the suction side, the screw rotor is in full-load suction state, at which time the working volume of the compressor is maximized. As the spool is separated from the suction side, it moves toward the exhaust side. A bypass cavity is formed between the slider and the suction side.Its presence causes the compressed gas in this range to be bypassed directly to the low pressure, and the actual suction volume of the screw rotor is reduced.The more the slide valve moves toward the exhaust side, the smaller the actual suction volume of the compressor will be.And the system cooling capacity will also reduce The slide valve is driven by the pressure differential among the internal capacity modulation system.The lubricant comes from the external oil separator and passes through the oil filter then enters into the oil inlet port of the compressor, and at last divided to bothsides of the piston. As a result, the piston can be controlled by discharging the high pressure lubricant at one side to low pressure, letting it flow to the low pressure side so that the slide valve will move with the piston to realize the loading and unloading of the compressor.The purpose of the piston spring is to push the piston to its initial position (min. load position), so as to realize the automatic unloading start. It not only reduces the mechanical impact on the compressor's moving parts, but also reduces the electrical current during compressor start up.Stepless capacity control, solenoid valve(SV1:unloading, SV3:50%, SV5:100%) is controlled by a micro controller or a thermal switch to adjust the piston smoothly to stably control cold output. If the oil filter capillary or solenoid valve of the capacity modulation system don't work properly, it will cause the capacity modulation system to be abnormal and fail.Figure 3-1.Capacity Modulation System3.2.1 Step type capacity modulation system1) Step type control logicY: Energize the solenoid valve N: Do not energize the solenoid valveTable 3-1. Step Type Capacity Modulation Control Logic2) Step type capacity modulation graphFigure 3-2. Step Type Capacity Modulation3)Step type control logic description10% loadFigure 3-3. 10% LoadWhen starting up thecompressor, SV1(unload) &SV2 (10%) need to beenergized to make the pistonkeep at the 10% position(leftside)In this state, the highpressure oil passes throughSV1(unload) then goes to theright side of the piston. At thesame time, the oil from left side of the piston passes through SV2 (10%) then discharge to the low pressure side. By doing so, the piston can be held at the 10% load position.★ Note: 10% load is for start up only. Running the compressor at 10% load for a long time is not recommended.50% loadAt this time, the capacity adjustment solenoid valves SV1 (unload) and SV3 (50%) are active.Under 50% load, SV1(unload) &SV3 (50%) are energized.In this state, the high pressure oil passes to the left side of the piston continuously. At the same time, the oil passes through SV1 (unload) then goes to the right side of the piston.If the piston is at the left side of the 50% hole (the loading is less than 50%), the oil at the right side of the piston will pass through SV3 (50%) and discharge to the low pressure side then the piston will move to right side until the position blocks the 50% hole. Thus the compressor is loaded to 50% smoothly.Vice versa, if the piston is at the right side of the 50% hole (the loading is more than 50%), the oil in the left side of the piston will pass through SV3 (50%) and go out to the low pressure side then the piston will move to left until the position blocks the 50% hole. Thus the compressor is loaded to 50% smoothly.75% LoadUnder 75% load, SV1(unload)&SV4 (75%)are energized.The logic of 75% load issimilar to that of 50%. Thepiston can be held around75% position by 75% holeto make the compressorrun under 75% load.Figure 3-5.75% Load100%LoadUnder 100% load, SV5(100%) is energized. In this state,the high pressure oil passes to theleft side of the piston continuously.At the same time, the oil in theright side of the piston passesthrough SV5 (100%) then goes tothe low pressure side to make thepiston be held at 100% position.fig3-6.100% Load4) Step type capacity modulation and water temperature controlFigure 3-7.Step type capacity modulation and water temperature control★Note: T & T' should be adjusted by system designer’s experience and practical application.Time启动Set point + 2TSet point + TSet pointSet point – T'Storage temperaturet1 t21~3min 60~90 sec3.2.2Stepless type capacity modulation systemStepless type is suitable when the refrigeration system needs to achieve precise control of cooling capacity.1)Stepless type control logicTable 3-2. Stepless Type Capacity Modulation Control Logic 50%~100%2)Stepless type capacity modulation graphFigure 3-8.Stepless Type Capacity Modulation3)Stepless type control logic descriptionIn stepless type capacity modulation system, the oil keeps going to the left side of the piston. The oil bypass in the left side of the piston is controlled by SV3 (50%). The oil inlet in the right side of the piston is controlled by SV1 (unload) and oil bypass in the right side of the piston is controlled by SV5 (100%). These three solenoid valves are controlled by temperature controller or PLC.Through the three solenoid valves, the cooling capacity can be controlled at any position from 50%~100%, so through periodical adjustment of SV1、SV3、SV5, the energy output can controlled stably.★Note: SV2(10%) can only be used for machine start and stop. Don't run the machine at 10% load for long time once the machine is started. It shall be switched to load model directly.The stepless type capacity modulation system shall be connected to the micro controller(optional), eg. PLC etc. in order to control the system at the target working condition.LoadDuring load process, the SV5 (100%) adopts pulse activating, and the rest solenoid valve are not energized.In this kind ofsituation, the highpressure oil goes into theleft side of the pistoncontinuously and the oilin the right side of thepiston bypasses throughSV5 (100%) to the lowpressure side.The piston willcontinue to move to theright side and thecompressor completeload process.Figure 3-9. LoadUnloadDuring unload process,the SV2(50%) stays active,and SV1 (unload) adopts pulseactivating, and the restsolenoid valve are notenergized.The high pressure oilcontinues to go to the left sideof the piston and goes into theright side of the piston passingthrough SV1(unload).Through SV3(50%), it Figure 3-10. Unload bypasses to the low pressure side, so that the piston continues to move to the left side, and the compressor will load to 50% piston.Keep load stateFigure 3-11. Keep Load StateDuring this process, all S/V are not energized. The high pressure oil coming continues to go to the left side of the piston. The left side oil inlet of the piston SV1(unload) and SV5(100%) are closed to keep the oil amount in the right side of the piston. The piston will not be able to move and stay at its original position, so that the compressor capacity will not change as well.Stepless type capacity modulation and water temperature controlBelow picture shows the load control of single compressor in the application of stepless type capacity modulation.Figure 3-12. Stepless Type Capacity Modulation★Note :X ′Upper Limit ;X 〞Lower Limit ;X Set Point ;H Control Range ;Y Actual valve❆ Description:● The actual water temperature exceeds the upper limit between A & B. Itmeans the compressor ought to unload until the actual value is within the control range.● The real value is smaller than the bottom line between C & D. It means therequired cooling capacity is decreasing and the compressor needs to be unloaded until the real value returns to the control range.Figure 3-13. Solenoid Valve Action Intervals-Stepless Type★Note :For detail stepless type capacity modulation control logic, please refer toTable 3-2Load/Unload functions between A and B, C and D.Energized :Solenoid valve is powered and energized Close : Solenoid valve is not energized T1,T3:Pulse time 0.5~1.5 seconds T2,T4:Pause time 10~20 secondsTime3.2.3The Location of the Solenoid Valves1)LT-83/41<-65/32Figure 3-14.LT-83/41<-65/32 solenoid valve location2)LT-20/10<-30/12<-45/20<-55/25Figure 3-15.LT-20/10<-30/12<-45/20<-55/25 Solenoid Valve Location3)Compressor unloading for startup, and stopTo decrease the mechanical loading to compressor’s parts and decrease the starting current during start up. Hanbell designs for LT compressor the function of unloading startup. To ensure compressor loads steadily, please follow Figure 3-16 to load step by step during the whole loading process.When compressor is about to shut down, it is also required to unload to ensure that the slide valve is at lowest loading position during next startup and compressor could have an unloading startup. Thus Hanbell requires no matter what load condition of the compressor is, it should be unloaded step by step till minimum load before stop according to below Figure 3-16.Figure 3-16. Compressor Startup and Stop ProcessCaution:1)A fter startup, keep the minimum load for 10 seconds. Before shut down, keep the minimum load for 30 seconds(Time can be set to 10~60seconds).2)A fter startup, when the pressure difference between high pressure and middle pressure is less than 3.5bar, the compressor shall be run at 10% load at low pressure stage. Don't load and open ECO.3)t=30 seconds(Time can be set to 30~60seconds).4)A fter the compressor shut down, the SV1 (unload) & SV2(10%) need to be still energized for 3 minutes, so as to ensure the compressor can still at min load position at next startup.5)H anbell strongly recommends that the compressor start-up and shutdown control logic shall refer to above graph. For detail informationplease refer to the regulations written in LT-S Control Requirements.4.LubricantTable 4-1. Lubricant SpecificationCaution:1)P lease refer to the table above to select the suitable lubricant and refrigerant and its operation range need to be taken into consideration as well.2)H anbell strongly recommends do not use the lubricant which isn’t certified by Hanbell since it may damage the compressor seriously.3)T his specification table is for LT series compressors only.4)T he oil temperature at the point when the compressor starts is suggested to be 5K higher than the corresponding saturation temperature of the oil separator in order to avoid too much oil containing in the refrigerant which may affect the lubricant. 5)A fter compressor stops, please turn on the oil heater of the external oil separator.If the compressor shuts down for a long time, please turn off the oil heater. Please heat the lubricant for more than 2 hours before next start up.1)B e sure to make the system clean and no welding spatter and other impurities before lubricant filling2)I n order to ensure that the system is dry enough, it should be dehumidified before filling. It is advisable to fill the system with dry nitrogen first and then vacuum the system. The vacuum time should be as long as possible. It is strongly recommended to repeat the above steps several times to minimize the water contained in the system.Caution1)D o not use the lubricant which is not approved by Hanbell, otherwise it may causeserious damage to the compressor2)D o not mix different brands of lubricants, otherwise they may cause serious damage to the compressor. Pay attention to it when replacing lubricating oil for the system.4.2The Replacement of Lubricant4.3.1Oil Change Schedule1)C heck lubricant every 10,000 hours after continuous running. For the first operation of the compressor, it is recommended to change the oil and clean the external oil filter after running 2,000 hours. Check the system whether clean or not and then change oil every 20,000 hours or after 4 years continuous running if the system operates in good condition.2)T he oil will deteriorate if the compressor runs at high discharging temperature (above 95℃) in the long term. Please avoid this situation, but if it’s necessary to run in this condition, please shorten the intervals of oil changing.4.3.2Pre-cautions for changing oil1)I t is recommended to check the quality of oil periodically in order to maintain the lubrication performance.2)T he lubricant absorbs moisture in the air. Avoid to expose it to the air for a long timeIf the compressor motor is burned, the acid and harmful substances and burned debris will be brought into the system. Therefore, the oil filters and lubricants must be replaced repeatedly. It is suggested to replace the lubricating oil again after 72 hours of operation until the quality of the lubricating oil in the system returns to standard valve.3)T he foreign body in the oil will block the oil line, so it is necessary to install an oil filter in the external oil line. Also, the pressure differential sensor need to be installed before and after the oil filter. If the pressure differential valve between these two sensors reaches 1.5 bar, the oil filter need to be changed.4)T he acidity of oil will directly affect the life of the motor, and it is recommended to change the oil when PH≤6. (Please also change the filter drier at the same time to make sure the system is dry.)5)I t is important to replace the oil, especially when the motor is burnt because the acidity remains in the system. By replacing the oil can help check the status of thesystem. Check the acidity of the lubricant, and re-change the oil after the system runs for 72 hours until the acidity of the lubricant reaches the standard valve.6)I n case of motor burned out, please not only change the compressor, but also change the oil and check the condition of the oil periodically. If the acidity excesses the standard, please change it immediately and always be aware of the cleanliness and moisture contained in the system.5. System Application★Note :Please consult Hanbell for parallel application and heat pump application.5.1 Piping Design5.1.1 Suction and Discharge Piping Layout1)Material and structure of suction and discharge pipeThe vibration of the compressor is small in normal operation, so it is not necessary to use flexible joints for suction and discharge tubes, but the pipes need to have enough flexible length to ensure the suction and discharge pipes won't cause any stress to the compressor. It is recommended to use copper tube for the suction and discharge piping in order to decrease the piping vibration when the compressor is in operation.2)The dimensions of suction and discharge piping:It is suggested to design the dimension of suction and discharge piping according to Hanbell recommendation (refer to 10.2.2).3)Piping for parallel systemTo improve the system operation efficiency, it’s necessary to reduce the gas -flow resistance and consider the oil return of suction piping. The recommended piping of suction and discharge side for parallel system is shown below:Be aware of the area of the main pipe should not be less than the area of the other pipes to make sure the pressure drops could be controlled in reasonable range. ❆ Piping at discharge side❆ x x xFigure 5-2 Suction Piping for Parallel SystemDetail Drawing 2 4) Suction filterThis model of compressor has a built-in suction filter, but it is only used as a final protection. It should not be used as an suction filter that needs to be cleaned regularly.So It is necessary to install a suction filter (25μm) which is easy to remove and clean it regularly.When the system is first used, it may need to be cleaned up frequently. If the pressure drop is bigger than 0.5 bar, the filter element should be replaced or cleaned until the system is clean. When the filter is disassembled, if the filter is found to be damaged, it needs to be replaced in time, and the impurities in the pipeline should be cleaned up. Ensure that the filter is oriented correctly during installation and it is recommended to add a shut-off valve at the inlet and outlet for easy maintenance.Hanbell The recommended suction filter design is shown in Figure 5-3 below.Figure 5-3.suction filterx xx Detail Drawing 2★Note:External suction filter should be used for cryogenic refrigeration systems。
Eluktronics MECH-15HS 用户手册说明书
NoticeThe information in this user’s manual is protected by copyright laws, all parts of this manual, including the products and software described in it, can not be reproduced, transmitted, transcribed, stored in a retrieval system, nor translated into any language.THE MANUFACTURER OR RESELLER SHALL NOT BE LIABLE FOR ERRORS OR OMISSIONS CONTAINED IN THIS MANUAL AND SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL DAMAGES, WHICH MAY RESULT FROM THE PERFORMANCE OR USE OF THIS MANUAL.The illustrations in this user’s manual are for reference only. Actual product specifications may vary with territories.The information in this user’s manual is subject to change without notice.TABLE OF CONTENTSNotice (2)Preface (5)1.1 Regulations Information (6)1.2 Safety Instructions (7)1.3 Conventions for this Manual (8)1.4 Release History (9)Getting to know the basics (10)2.1 Product Specification (11)2.2 Preparing your Computer (15)2.3 Product Overview (16)Getting started (24)3.1 AC Adapter (25)3.2 Knowing the Keyboard (26)3.2.1 For keyboard users (27)3.3 Using the touchpad / clickpad (30)3.3.1 Windows 10 Touchpad Usage (31)BIOS setup (32)4.1 About BIOS Setup (33)4.1.1 When to Use BIOS Setup ? (33)4.1.2 How to Run BIOS Setup ? (33)4.2 BIOS Setup Menu (34)4.2.1 Main Menu (36)4.2.2 Advanced Menu (38)4.2.3 Security Menu (40)4.2.4 Boot Menu (41)4.2.5 Exit Menu (42)Chapter 1 Preface1.1 Regulations Information¤ CE complianceThis device is classed as a technical information equipment (ITE) in class B and is intended for use in living room and office. The CE-mark approves the conformity by the EU-guidelines:- EMC Directive 2014/30/EU,- Low Voltage Directive 2014/35/EU(equals A2 : 2013) ,- R&TTE Directive 1999/5/ECT he unit can be operated at an ambient temperature of max. 35°C (95°F). Do not subject it to temperatures below 5°C (41°F) orabove 40°C (104 °F).C AUTION: R ISK OF EXPLOSION IF BATTERY IS REPLACEDBY AN INCORRECT TYPE DISPOSE OF USEDBATTERIES ACCORDING TO THE INSTRUCTIONS.P REVENTION OF HEARING LOSSC AUTION: L istening to music at high volume levels and forextended durations can damage one’s hearing. In orderto reduce the risk of damage to hearing, one should lowerthe volume to a safe, comfortable level, and reduce theamount of time listening at high levels. Headsets shouldcomply with EN 50332-2 requirements.1.2 Safety InstructionsDo not apply heavy pressure to the computer or subject it to any form ofstrong impact as this can damage the computer's components or otherwisecause it to malfunction.To keep your computer in prime operating condition, protect your work area from direct sunlight.Never cover or block the air vents including those located at the base of thecomputer. Never cover your computer or AC adapter with any object.Do NOT expose to or use near liquid, rain, or moisture.Do NOT use the modem during electrical storms.Do not use or expose this device around magnetic fields as magneticinterference may affect the performance of the device.152341.3 Conventions for this Manual1.4 Release History1.009.2017Initial releaseChapter 2Getting to know the basics2.1 Product SpecificationThis User’s Manual provides technical information of instructions and illustrations on how to operate this notebook for the customer. Please read this manual carefully before using this notebook.・CPUSupport ProcessorKBLH, 4+2・MemoryDDR4DDR4 2400MHz・StorageHDD2.5” SATA HDD support7/9.5mm・Physical CharacteristicDimension386.9 x 270 x 35.6mm; Weight: 3.0Kg・GPUSupport ProcessorNVDIA Geforce 1070, 256bits(N17E-G2)・I/O PortDC-in USBRJ45Card Reader HDMIx 1x 1x 1 (2 in 1 Card reader connector type) x 1 2.0 x 2 + 3.0 x 33.1 x 1 (Type C, no Audio and Video support)・AudioAudio CodecSpeaker/MICAzalia standard support, D3 mode supportAudio out & Mic in x 2Build-in 2 speakers Speaker : 2W/eachDigitial Microphone support w/ CameraDP port x 1 Quick launch buttonx 1 (FAN full speed ON/OFF)・InputKeyboard15.6”Pointing DevicePS2 Touch Pad with 2 buttons 92X52mmLCD15.6" FHD, 16:9, Glare or AG・DisplayLAN10/100/1000 Mb/SecWireless LANM.2 2230 w/ PCIE interfaceIEEE802.11b/g/n support; AC mode support ・Communication PortHD webcamHD webcam with D-MIC*1・Webcam・PowerAC AdapterAutomatics Voltage adjustment between 100 and 240VAC 50/60Hz, 230 Watts (19.5V/11.8A), 3 PinsLi-ion 18650 Battery, hard pack, Removable,6 cells (High power 3S2P 4300mAh ; or Normal 3S2P 4400mAh)BatteryPlease use the genuine adapter based on the rating of your PC's model and BIOS. If damage is determined to have been caused by utilization of an unauthorized power supply, the warranty will be void.CAUTION: MODEL IS DESIGNED TO USE WITH THE DC INPUT: 19.5V/11.8A2.2 Preparing your ComputerAConnect the AC adapter’s DC output plug to the DC IN jack.Top-Open View2.3 Product OverviewPlease become familiar with each component before you operatethe computer.CAUTION:When you are not using the computer, keep the LCD-screen closed to protect it from dust.13WebcamA device that allows you to record video or take photographs with yourcomputer.274Power ButtonPress this button to turn the computer's power on or off.56Camera Status LEDThe Camera Status LED shows the Camera status.MicrophoneBuilt-in microphone.LCD screenDisplays of your notebook computer.Power indicator*Power ON: ON*Suspend: Slow / Smooth, Blinking Red *FAN full speed: ON*Power Off: OFFCharging & Battery indicator*Charging: Red*Battery Low (<6%): Blinking Red*Charging finish : OFF*Power Mode: Blinking Red between Power & Charging Indicator WIFI CONTROL BUTTONSCREEN CONTROL BUTTONBottom Side ViewTouchpad/Click padTouch-sensitive pointing device which functions like the mouse.The left and right buttons function like the left and right buttons on astandard mouse.Left and right touchpad/Clickpad buttons8KeyboardThe keyboard provides keys with comfortable travel.91012345NOTE :The product’s thermal vent design may vary depending on the model and internal hardware in which you purchased.1Battery Lock 1 and 2 - SpringThe spring battery lock 1 and 2 are used to keep the battery pack secured.Lock 1Switch lock 1 by manual to lock or unlock.Lock 2When the battery pack is inserted, lock 2 will automatically lock.To remove the battery pack, lock 2 must be held in the unlocked position.2Battery Module34VentsHDD / RAM / SSD / WLAN Compartment CoverThe cover can be removed to install or remove the HDD / RAM/ SSD / WLAN. If damage occurs while attempting to modify orremove parts, it will not be protected under warranty.5HDD / RAM / SSD / WLAN Compartment Cover Screws You can remove the screws to install or remove the HDD / RAM / SSD / WLAN compartment cover. ( Please refer to the HDD /RAM / SSD / WLAN compartment view on the following page.)The thermal vents help the processor to avoid overheating.The thermal vents are designed to cool the internal components and avoid overheating.HDD / RAM / SSD / WLAN Compartment View (Optional)If you intend to modify or upgrade your SSD, RAM or WLAN parts, please*******************************************.Theuseofunauthorized parts will not void your warranty. However, any aftermarket or third party part must be removed before requesting warranty assistance.Right Side ViewLeft Side View3USB Ports Connects an USB device.(such as USB Zip drive, keyboard or mouse) into this jack.Audio Out JackConnects amplified speakers, headphones or microphone into this jack.12Mic In JackConnects amplified speakers, headphones or microphone into this jack.4 2 in 1 Card ReaderInsert Memory Card.1Stereo speakersProduce stereo sound. Back Side View1 2VentsPower ConnectorConnects the AC adapter into this connector.The thermal vents are designed to cool the internal components and avoid overheating.34Network JackHDMI portSupports high-definition digital video connections.56Display PortUSB PortConnected to the screen, or home theater system.7USB PortConnects an USB device (such as USB Zip drive, keyboard ormouse) into this jack.This jack allows you to connect to a Local Area Network (LAN) connection.Connects an USB device (such as USB Zip drive, keyboard ormouse) into this jack.-Intelligent charging 1.8A function for external USB device in power off mode.Shutdown state, continue to press the power button for about 6seconds, Power USB is enabled; under-powered USB shutdownstate, rst press the power button to cancel this function, press the power button is turned on.Chapter 3 Getting started3.1 AC AdapterDC IN123NOTE: The power adapter can become hot when in use. Please be sure the AC adapter is not covered with any materials keep it away from exposed parts of your body. The AC adapter appearance may vary depending on your region.CAUTION: The use of inferior extension cords may result in damageto your notebook. Your notebook comes with its own authorized ACadapter. Use of a different AC adapter or cable extension whichis not authorized for use will void warranty protection if damage tohardware is found in association to said adapter or extension cable. Please plug in the AC adapter for initial use of your notebook until your battery levels are verified to provide sufficient power. The AC adapter should be plugged back in as soon as your PC indicates the battery level is low. If the battery is continuously utilized past the point of indication of a low battery, it can affect the longevityof your battery. If you intend to remove the battery and use the PC under AC power only, the battery should be stored at room temperature at a charge level between 55-65% before removal. Note that the AC adapter included in the package is approved for your notebook; using other adapter model may damage either the notebook or other devices attached to it.3.2 Knowing the KeyboardThe following defines the colored hot keys on the Keyboard. The colored commands can only be accessed by first pressing and holding the function key while pressing a key with a colored command.3.2.1 For keyboard usersTo activate these functions, press the hot key associated with the desired function as below :Function KeysFunction KeysFunction Keys3.3 Using the touchpad / clickpad Press the left 1 and right 2 buttons located on the edge of the touchpad / clickpad to make selections and run functions. These two buttons are similar to the left and right buttons on a mouse. Tapping on the touchpad / clickpad produces similar results.The touchpad / clickpad is a rectangular electronic panel located just below your keyboard. You can use the static-sensitive panel of the touchpad / clickpad and slide it to move the cursor. You can use the buttons below the touchpad as left and right mouse buttons.Modern touchpad gesture:A modern touchpad should support the core touch gestures described in the following table.Touch Pad Gesture 3.3.1 Touchpad UsageChapter 4 BIOS setupNOTE : The drivers, BIOS and utilities bundled in the support DVD may vary by models and are subject to change without notice.4.1 About BIOS Setup4.1.1 When to Use BIOS Setup ?4.1.2 How to Run BIOS Setup ?You may need to run the BIOS Setup when:・ A n error message appears on the screen during the system booting up and is requested to run SETUP.・ Y ou want to change the default settings for customized features.・You want to reload the default BIOS settings.To run the BIOS Setup Utility, turn on the notebook and press the [Del] key during the POST procedure.If the message disappears before you respond and you still wish to enter Setup, either restart the system by turning it OFF and ON, or simultaneously pressing [Ctrl]+[Alt]+[Del] keys to restart.Be noted that the screen snaps and setting options in this chapter are for your references only.The actual setting screens and options on your Notebook may be different because of BIOS update.The setup function only can be invoked by pressing [Del] or [F2] key during POST that provide a approach to change some setting and configuration the user prefer, and the changed values will save in the NVRAM and will take effect after the system rebooted. The setup uses a menu interface to allow the user to configure their system and the features are briefly listed as follow.Press [F7] key for Boot Menu.4.2 BIOS Setup MenuOnce you enter the BIOS Setup Utility, the Main Menu will appear on the screen. Select the tags to enter the other menus.Main MenuShow system overview about memory size,setting of system time and date.Advanced MenuTo select the XD feature enable or disable XD feature only work with Intel platform + Windows.Security MenuInstall or clear the password settings for supervisor and user. Boot MenuConfigure Settings during System Boot.EXIT MenuSave or discard the changes before leaving the BIOS Setup Menu.4.2.1 Main Menu・System TimeThis item allows you to set the system time. There is a small internal (CMOS) battery which is designed to maintain your system clock. It is designed to maintain time even when thePC is powered down or in sleep mode. The time format is [hour:minute:second].Use [+] or [-] to configure system Time.・System DateThis item allows you to set the system date. The date format is [day:month:date:year].Day Day of the week, from Sun to Sat, whichis determined by BIOS (read-only).Month (Month)The month from 01 (January) to 12(December).Date (Date)The date from 01 to 31.Year (Year)The year can be adjusted by users.・Total MemoryThis allows you to see the total amount of memory.4.2.2 Advanced Menu• Wake on LANEnable/Disableintegrated LAN to wake the system.• Serial ATA HDDIt will show AHCI SATA HDD info.・NVMe DeviceEnable/Disableintegrated NVMe to wake the system.・Intel Virtualization TechnologyWhen enabled, a VMM can utilize the additional hardware capabilities provided by Vanderpool Technology.・RAID mode reminderPlease update strip size in BIOS to 128K in order for RAID to optimize performance.4.2.3 Security Menu・Change Administrator PasswordWhen this item is selected, a message box shall appear on the screen as below:Enter New PasswordType a maximum of 20-digit password and press [Enter].The password typed now will replace any previously set password from CMOS memory. You may also press [ESC] to abandon new password setting. It is extremely important to keep record for any BIOS password which is set as it can not be reset even with the removal of a CMOS battery for the security of your PC.Select Change User Password to give or to abandon password setting same as Change Administrator Password item above.Note that Administrator Password field allows users to enter and change the settings of the BIOS SETUP UTILITY, while User Password field only allows users to enter the BIOS SETUP UTILITY without having the authorization to make any change.The Password Check item is used to specify the type of BIOS password protection that is implemented.To clear a set Administrator Password/ User Password, just press [Enter] under Change Administrator Password/ Change User Password field when you are prompted to enter the password. A message box will pop up confirming password will be disabled. Once the password is disabled, the system will boot and user can enter setup without entering password.4.2.4 Boot Menu・Boot ConfigurationConfigure Settings during System Boot.・LAN Remote Boot [Disable]: Boot from LAN or not.・Set Boot Priority (1st/2nd/3rd/..... Boot)Specifies the boot sequence from the available devices.A device enclosed in parenthesis has been disabled in the corresponding type menu.・ Hard Disk Drive / USB HardDisk DriveSpecifies the Boot Device Priority sequence.4.2.5 Exit Menu・Save Changes and ResetExit system setup after saving the changes.F4 key can be used for this operation.・Discard Changes and ExitExit system setup without saving any changes.ESC key can be used for this operation.・Restore DefaultsRestore/Load Defaults values for all the setup options.F3 key can be used for this operation.。
海南迅捷1U系列纤薄式水化磁闸产品简介说明书
SL1005C2BTA1SL1010C2BTA1SL1040C2BT SL1045C3BTA1SL1050C2BTA1 SL1020C2BTA1SL1035C2BTA1SL1040C2BTA2Increase Your Power DensityWith Eaton’s new Heinemann 1U Series Slimline Hydraulic Magnetic Circuit Breaker you can increase your power density without sacrificing performance. The 1U Series Slimline offers the precision performance of a full size hydraulic magnetic breaker in a miniaturized package.Designed specifically for rack-mount applications,the Slimline's reduced height is ideal for tight spaces and the protection of the latest 1U devices.The 1U Series Slimline is the first hydraulic magnetic breaker to use a snap action mecha-nism which improves reliability,safety and performance. With snap action, the contacts are controlled by a stored energy mechanism that closes in one swift action when the operator switches the handle to the ON position. This advanceddesign prevents premature contact failure, improvesefficiency and allows for higher current ratings.The 1U Series Slimline com-pact size allows greater design flexibility and saves valuablerack space without sacrificing performance. All configurations are UL ா489 listed for branch circuit protection and conform to IEC standards. Available with an integral auxiliary switch, the breaker allows for integration into the most complex systems.Take your equipment to a new level of power density and protection, never before possible. Learn about how the new Eaton 1U Series Slimline is revolutionizing the dc power protection market today.1U Series Slimline Product Highlights•Proven reliability of the Heinemann Hydraulic Magnetic Trip Unit.•Patented snap action technology for improved performance and reliability.•World’s first circuit breaker designed for 1U height rack-mount applications.•Ambient compensating trip unit from -40˚ to +80˚C.•1.0 – 100 ampere continuous current ratings (100% rated).•80 Vdc rating.•UL 489 listed.•CE mark. •Integral auxiliary switch option.•Bullet, screw or stud terminals.•Panel removal tool.•Standard distribution panel configurations available.Eaton Electrical Inc.1000 Cherrington Parkway Moon Township, PA 15108United Statestel: 1-800-525-2000© 2006 Eaton Corporation All Rights Reserved Printed in USAPublication No. PA01106001E / Z4344April 2006UL is a federally registered trademark of Underwriters Laboratories Inc. Heinemann is a federally registered trademark of Eaton Corporation.Typical DimensionsPERFORMANCE DATACurrent Range 1 – 100 A 1Continuous (100% Rated)VoltageUp to 80 Vdc or up to 240 Vac 1Interruption Rating 10 kA @ 80 Vdc 1or 10 kA @ 240 Vac 1Delay Curves Medium, Short, Instantaneous Operating Temperature -40 to + 80ºCTerminals Screw, Stud or Bullet ApprovalsUL 489 Listed, CE MarkAuxiliary Switch Rating 100 mA @ 80 Vdc or 300 mA @ 30 Vdc1Phase I Launch 5 – 60 A, 80 Vdc, 5 kA, UL 489. Consult Customer Service for availability of future releases.Catalog Number Configuration GuideUse the table below to select the correct standard catalog number for your application. Standard configuration consists of Series Trip,Imperial Mounting Inserts, UL 489 Listing and Screw Terminals. We also offer custom configurations and assembled DC distribution panels. To get additional technical assistance or for more information about custom applications, call +1 800 356 1243 (Americas), +41 21 841 92 11 (EMEA) or +86 512 6716 3397 (Asia).Auxiliary Switch OptionCATALOG NUMBERING SYSTEMNote:Catalog number example — SL1005C2.2Phase I Launch 5 – 60 A, 80 Vdc, 5 kA, UL 489. Consult Customer Service for availability of future releases.3No catalog designation is required for a standard catalog configuration.SL1005C2BTA1SL1010C2BTA1SL1040C2BT SL1045C3BTA1SL1050C2BTA1 SL1020C2BTA1SL1035C2BTA1SL1040C2BTA2。
斯坦纳升降平台SL系列说明书
THIS MANUAL IS TOBE LEFT WITH THEFOLLOWINGCONTRACT:STANNAH PART NO:912248ELECTRICAL WIRING MANUALMIDILIFT SLISSUE:26Midilift SL - relay assembly detail for fire alarm shutdown to ground floor Midilift SL - PLC connection details Midilift SL - second entrance at one level connection details Midilift SL - landing station cable loom connection details Midilift SL - carriage cover DDU connection details Midilift SL - alarm sounder connection details Midilift SL - 0.15m/s pump unit connection details Midilift SL - UPS battery back up connection details Midilift SL - trailer cable connection details Midilift SL - carriage cover controls with joystick option Midilift SL - remote alarm volt free contacts option connection details Midilift SL - shaft roof LED lighting connection details Midilift SL - autodial connection details Midilift SL - telephone option connection details Midilift SL - automatic door connection details Midilift SL - position switches connection details Midilift SL - pit stop / prop connection details Midilift SL - carriage safety edge connection details Midilift SL - 0.08m/s pump unit connection details Midilift SL - landing station connection details with call isolation Midilift SL - landing station connection details Midilift SL - carriage front cover connection details Midilift SL - carriage component tray connection details Midilift SL - main key wiring diagram DF9444/32B9444/1079444/919444/132C9444/589444/579444/489444/34FGG9444/1269444/1089444/99444/199444/129444/79444/6DLHDB 9444/1039444/1179444/1049444/59444/86KB 9444/1029444/39444/29444/1K B K O UPDATEDDRAWINGS(*)DRAWINGNUMBER REV DRAWING DESCRIPTION INDEXACC9444/105B Midilift SL - landing station lock and beak connection details A6101110A Midilift SL - earth bonding connection details **Midilift SL - Videx Intercom connection details9444/131*AG8G8APMENDVTRAILER CONNECTION PCB (9300/35)KS1SPE N L G/Y (LINK)BLUE BROWN N L BLUE (LINK)BROWN MAINS FILTER G8A G8DV B-PM L N (LINK)G/Y G/Y (LINK)N L EPUMP MOTOR TERMINALS (240VAC)DOWN VALVE TERMINALS (24VDC)+-OLW SPADE TERMINALS (N/C)BLUE G/Y BROWN BROWN BLUE 3 CORE CABLE (0.75mm)G/Y BROWNBLUEG/Y WIRE 2WIRE 1WIRE 2WIRE 1 2 CORE CABLE WIRE 2WIRE 1RED GREEN RED 3 CORE CABLEGREENREDGREENG/Y ELECTRICAL COMPONENT ENCLOSURE PUMP UNIT ENCLOSURE WIRE 5WIRE 3G/Y (LINK)WIRE 210 CORE MOTOR CABLE 0.75mm (1-9 + G/Y)OVERLOAD 12PE E E E BLUE OL3BLUE3BLUELB-KS2OL3WIRE 1WIRE 8WIRE 7WIRE 6WIRE 4PL5230VAC 50Hz SUPPLY (BY OTHERS)FOR CONTRACTS WITH BATTERY BACKUP SEE DRAWING 9444/58EARTH BONDING SEE DRAWING 6101110 FOR EARTH BONDING DETAIL OF MIDILIFT SL BROWN BLUE G/Y 3 CORE CABLE (1.5mm)G/Y EARTH BLOCK MOUNTED ON TRAILER SUPPORT BRACKETG/Y (LINK)E BROWN BROWN WIRE 2WIRE 1BLUE GREEN RED BLUE G/Y G/Y WIRE 1WIRE 2WIRE 3WIRE 4WIRE 5WIRE 6WIRE 7WIRE 8G/Y (LINK)6AMP = 10LTR JASON PUMP 7AMP = 7.5LTR RFP PUMP 8AMP = 10LTR RFP PUMP DRAWING NO:NAME:CHECKED:Tel: 01264 339090 Fax: 337942REV:HEAD OFFICE:Anton Mill Andover Hampshire SP10 2NX England DATE:DATE:M.HOOD 24/05/02R.BAUGH 24/05/02MIDILIFT SL - PUMP UNIT CONNECTION DETAILS (0.08m/s)9444/5KREV I. PRESSURE SWITCH WIRING CORRECTED TO COLOUR CODED. 30/06/10 JN.REV H: THERMAL OVERLOAD OPTION ADDED 25/06/09 MHREV F: TRAILER CABLE REMOVED AND EARTH BONDING NOTICE ADDED 25/04/05 MHREV E: TRAILER CABLE LABELLED 'CABLE 1' 05/09/03 MHREV D: OLW INDICATOR CONNECTION DETAILS ALTERED TO SUIT COMMUNICATION OPTIONS 03/02/03 MH REV C: SPARE TRAILER WIRES IDENTIFIED 11/11/02 MHREV B: TERMINATIONS ALTERED TO MATCH TRAILER PCB AND OVERLOAD INDICACTION 12/08/02 MH REV A: CARRIAGE ISOLATION SWITCH TERMINALS ALTERED 02/07/02 MH REV J: OLW TERMINAL CHANGED FROM 4 TO 3 & UPDATED FOR NEW LOGO AND TEXT FONT. 13/09/2010 JN.REV K: AMENDED TO HIGHLIGHT 0.08m/s AND REMOVAL OF HYDRAX REFERENCE. 24/02/2014 MH ECN5562G8G8APMENDVTRAILER CONNECTION PCB (9300/35)KS1SPN L BLUE BROWN N L BLUE (LINK)BROWN MAINS FILTER N1B-DV G8OL3(LINK)N L EPUMP MOTOR TERMINALS (240VAC)DOWN VALVE TERMINALS (24VDC)+-BLUE G/Y BROWN BROWNBLUE 3 CORE CABLE (0.75mm)G/Y BROWNBLUEG/Y BLUE BROWNBLUE BROWN 2 CORE CABLE BLUEBROWNBROWN GREEN 3 CORE CABLEELECTRICAL COMPONENT ENCLOSURE PUMP UNIT ENCLOSURE WIRE 5WIRE 3G/Y (LINK)WIRE 210 CORE MOTOR CABLE 1mm (1-9 + G/Y)10 AMPS PM WHITE LB-KS2OL3WIRE 1WIRE 8WIRE 7WIRE 6WIRE 4PL5230VAC 50Hz SUPPLY (BY OTHERS)FOR CONTRACTS WITH BATTERY BACKUP SEE DRAWING 9444/58EARTH BONDING SEE DRAWING 6101110 FOR EARTH BONDING DETAIL OF MIDILIFT SL BLUE BROWN G/Y 3 CORE CABLE (1.5mm)G/Y EARTH BLOCK MOUNTED ON TRAILER SUPPORT BRACKETG/Y (LINK)G8A GREEN BROWN G/Y WIRE 8WIRE 7WIRE 6WIRE 5WIRE 4WIRE 3WIRE 2WIRE 1OVERLOAD E E L1N L BROWN WHITE BLUE BROWN BROWN BLUE G/Y BROWN BLUE OUT IN G/Y BLUE BROWN WHITEWHITE GREENBROWN GREEN BROWN HYDRAULIC PRESSURE SWITCH COM N/O N/C DRAWING NO:NAME:CHECKED:Tel: 01264 339090 Fax: 337942REV:HEAD OFFICE:Anton Mill Andover Hampshire SP10 2NX England DATE:DATE:J.NICHOLLS 16/08/13M.HOOD 16/08/13MIDILIFT SL - PUMP UNIT CONNECTION DETAILS (0.15m/s)9444/132CREV A: INTERNAL WIRE NUMBERS CHANGED TO COLOURS TO REFLECT IGV REV 2 DRAWING AND PL5WIRING CORRECTED DUE TO INCORRECT WIRING OF PRESSURE SWITCH . JN 04-09-13REV B: FLYBACK DIODE ADDED BETWEEN B- AND DV. JN 09-09-13REV C: AMENDED TO REMOVE IGV FROM TITLE BLOCK. MH 24-02-14 ECN5562SPECIAL OPTION TRAILER CABLE 7 CORE (0.75MM)PL1032GREEN/WHITE BLUE/WHITE ORANGE/WHITE PL1132BLACK GREY ORANGE TRAILER CONNECTION PCB (9300/35)55WHITE/BLUE BLUE 44PL8B-5 WAY MALE CONNECTOR 905151 5 WAY FEMALE CONNECTOR 905152WIRE 1WIRE 2WIRE 3WIRE 4BLACK GREY ORANGE BLUE SPECIAL OPTION TRAILER CABLE 7 CORE (0.75MM)GREEN/WHITE BLUE/WHITE ORANGE/WHITE TRAILER CONNECTION PCB (9300/35)WHITE/BLUE 5 WAY MALE CONNECTOR 90515112V 0V VX15221T 24V LEGEND HALO ALARM N/O N/O ALB EXISTING CIRCUIT 5 WAY FEMALE CONNECTOR 905152WIRE 1WIRE 2WIRE 3YELLOW 5 CORE (0.5MM)WIRE 1WIRE 2WIRE 3WIRE 4WIRE 4YELLOW WIRE 4YELLOW WHITE/GREEN BLACK PL1032PL1132BLACK GREY ORANGE 55BLUE 44BLACK BLACK GREY ORANGE BLUE PL8B-CARRIAGE COVER 6 CORE VIDEX INTERCOM CABLE WHITE/BLUE ORANGE/WHITE GREEN/WHITE BLUE/WHITE 13ART.31116246 CORE VIDEX INTERCOM CABLE WHITE/BLUE ORANGE/WHITE GREEN/WHITE BLUE/WHITE 21ART.5112/ART.5118435WHITE/GREEN SIMPLEX OPTION STANDARD HANDSET 12V 0V VX15221T 24V LEGEND HALO ALARM N/O N/O ALB EXISTING CIRCUIT WIRE 1WIRE 2WIRE 3YELLOW 5 CORE (0.5MM)WIRE 4YELLOW WIRE 4YELLOW BLACK BLACK CARRIAGE COVER NAME:CHECKED:DATE:DATE:J.KENT 09/04/13M.HOOD 09/04/13。
爱森莱特198901快速连接器速度调节器说明说明书
Eaton 198901Eaton Moeller® series Rapid Link - Speed controllers, 5.6 A, 2.2 kW, Sensor input 4, Actuator output 2, 180/207 V DC, Ethernet IP, HAN Q4/2, with manual override switchEaton Moeller® series Rapid Link Speed controller198901157 mm270 mm 220 mm 3.59 kgIEC/EN 61800-5-1 RoHS UL 61800-5-1 UL approval CERASP5-5421EIP-412R000S1Product NameCatalog NumberProduct Length/Depth Product Height Product Width Product Weight Certifications Catalog Notes Model Code3 fixed speeds and 1 potentiometer speedcan be switched over from U/f to (vector) speed control Connection of supply voltage via adapter cable on round or flexible busbar junction480 VIs the panel builder's responsibility. The specifications for the switchgear must be observed.400 V AC, 3-phase480 V AC, 3-phaseMeets the product standard's requirements.2.2 kW500 VMeets the product standard's requirements.-40 °C380 VControl unitKey switch position HANDTwo sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation2 Actuator outputsManual override switchIGBT inverterKey switch position OFF/RESETThermo-click with safe isolationInternal DC linkPTC thermistor monitoringSelector switch (Positions: REV - OFF - FWD)Key switch position AUTOPC connection0 Hz200 %, IH, max. starting current (High Overload), For 2 seconds Generation Change RA-SP to RASP5Configuration to Rockwell PLC for Rapid LinkGeneration Change RASP4 to RASP5Generation change from RA-MO to RAMO 4.0Generation change RAMO4 to RAMO5Generation change from RA-SP to RASP 4.0Rapid Link 5 - brochureDA-SW-drivesConnect - InstallationshilfeDA-SW-Driver DX-CBL-PC-3M0DA-SW-USB Driver DX-COM-STICK3-KITDA-SW-drivesConnectDA-SW-drivesConnect - installation helpDA-SW-USB Driver PC Cable DX-CBL-PC-1M5Material handling applications - airports, warehouses and intra-logistics ETN.RASP5-5421EIP-412R000S1.edzIL034093ZUrasp5_v31.stpramo5_v31.dwgDA-DC-00004508.pdfDA-DC-00004514.pdfDA-DC-00004184.pdfDA-DC-00003964.pdfeaton-bus-adapter-rapidlink-speed-controller-dimensions-002.eps eaton-bus-adapter-rapidlink-speed-controller-dimensions-005.eps eaton-bus-adapter-rapidlink-speed-controller-dimensions-003.eps eaton-bus-adapter-rapidlink-speed-controller-dimensions-004.epsMains voltage - max10.11 Short-circuit ratingRated operational voltage10.4 Clearances and creepage distancesOutput at quadratic load at rated output voltage - max Output voltage - max10.2.3.1 Verification of thermal stability of enclosures Ambient storage temperature - minMains voltage - minFitted with:Output frequency - minStarting current - max Applikasjonsmerknader BrosjyrereCAD model Installeringsinstruksjoner mCAD model SertifiseringsrapporterTegningerevery 20 seconds, Power sectionRated conditional short-circuit current (Iq)10 kAAmbient operating temperature - max40 °CCommunication interfaceEthernet IP, built inAssigned motor power at 115/120 V, 60 Hz, 1-phase3 HPOutput frequency - max500 HzSwitching frequency8 kHz, 4 - 32 kHz adjustable, fPWM, Power section, Main circuitFeaturesParameterization: drivesConnectParameterization: KeypadParameterization: drivesConnect mobile (App) Parameterization: FieldbusAmbient operating temperature - min-10 °CBraking current≤ 0.6 A (max. 6 A for 120 ms), Actuator for external motor brakeNumber of HW-interfaces (serial TTY)10.6 Incorporation of switching devices and componentsDoes not apply, since the entire switchgear needs to be evaluated.Nominal output current I2N5.6 A10.2.6 Mechanical impactDoes not apply, since the entire switchgear needs to be evaluated.10.3 Degree of protection of assembliesDoes not apply, since the entire switchgear needs to be evaluated.Product categorySpeed controllerRadio interference classC2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.C1: for conducted emissions onlyHeat dissipation capacity Pdiss0 WRated control voltage (Uc)180/207 V DC (external brake 50/60 Hz)24 V DC (-15 %/+20 %, external via AS-Interface® plug)Assigned motor power at 460/480 V, 60 Hz, 3-phase3 HPNumber of HW-interfaces (RS-422)Mains current distortion120 %ProtocolEtherNet/IP10.9.2 Power-frequency electric strengthIs the panel builder's responsibility.Overvoltage categoryIIIDegree of protectionIP65NEMA 12Ambient storage temperature - max70 °CRated impulse withstand voltage (Uimp)2000 VConnectionPlug type: HAN Q4/2Overload currentAt 40 °CFor 60 s every 600 sFunctions1 potentiometer speedFor actuation of motors with mechanical brake3 fixed speedsOutput at linear load at rated output voltage - max2.2 kWMains voltage tolerance380 - 480 V (-10 %/+10 %, at 50/60 Hz)Leakage current at ground IPE - max3.5 mAConverter typeU converter10.2.2 Corrosion resistanceMeets the product standard's requirements.Supply frequency50/60 Hz10.2.4 Resistance to ultra-violet (UV) radiationMeets the product standard's requirements.10.2.7 InscriptionsMeets the product standard's requirements.Shock resistance15 g, Mechanical, According to IEC/EN 60068-2-27, 11 ms, Half-sinusoidal shock 11 ms, 1000 shocks per shaftApplication in domestic and commercial area permittedYesNumber of inputs (analog)Number of phases (output)310.12 Electromagnetic compatibilityIs the panel builder's responsibility. The specifications for the switchgear must be observed.10.2.5 LiftingDoes not apply, since the entire switchgear needs to be evaluated.Number of HW-interfaces (RS-485)1Number of HW-interfaces (industrial ethernet)2Efficiency98 % (η)System configuration typeCenter-point earthed star network (TN-S network)AC voltagePhase-earthed AC supply systems are not permitted.10.8 Connections for external conductorsIs the panel builder's responsibility.ProtectionFinger and back-of-hand proof, Protection against direct contact (BGV A3, VBG4)Braking voltage280/207 V DC -15 % / +10 %, Actuator for external motor brakeApplication in industrial area permittedYesClimatic proofing< 95 %, no condensationIn accordance with IEC/EN 5017810.9.3 Impulse withstand voltageIs the panel builder's responsibility.Overload current IL at 150% overload8.4 AInput current ILN at 150% overload5.3 ANumber of HW-interfaces (RS-232)Number of inputs (digital)4Current limitationAdjustable, motor, main circuit0.5 - 5.6 A, motor, main circuitCable lengthC3 ≤ 25 m, maximum motor cable lengthC1 ≤ 1 m, maximum motor cable lengthC2 ≤ 5 m, maximum motor cable length10.5 Protection against electric shockDoes not apply, since the entire switchgear needs to be evaluated.Mounting positionVerticalMains switch-on frequencyMaximum of one time every 60 seconds10.13 Mechanical functionThe device meets the requirements, provided the information in the instruction leaflet (IL) is observed.10.9.4 Testing of enclosures made of insulating materialIs the panel builder's responsibility.Heat dissipation per pole, current-dependent Pvid0 WElectromagnetic compatibility1st and 2nd environments (according to EN 61800-3)Resolution0.1 Hz (Frequency resolution, setpoint value)Assigned motor power at 460/480 V, 60 Hz3 HPRelative symmetric net voltage tolerance10 %Rated operational current (Ie)5.6 A at 150% overload (at an operating frequency of 8 kHz and an ambient air temperature of +40 °C)Number of outputs (analog)Rated operational power at 380/400 V, 50 Hz, 3-phase2.2 kWNumber of HW-interfaces (USB)Operating modeBLDC motorsU/f controlSensorless vector control (SLV)Synchronous reluctance motorsPM and LSPM motorsRated frequency - min45 HzDelay time< 10 ms, Off-delay< 10 ms, On-delayNumber of outputs (digital)2Power consumption58 W10.2.3.2 Verification of resistance of insulating materials to normal heatMeets the product standard's requirements.10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effectsMeets the product standard's requirements.Number of HW-interfaces (other)Rated frequency - max66 HzVibrationResistance: 57 Hz, Amplitude transition frequency on accelerationResistance: 10 - 150 Hz, Oscillation frequencyResistance: 6 Hz, Amplitude 0.15 mmResistance: According to IEC/EN 60068-2-6Short-circuit protection (external output circuits)Type 1 coordination via the power bus' feeder unit, Main circuit10.7 Internal electrical circuits and connectionsIs the panel builder's responsibility.Braking torqueAdjustable to 100 % (I/Ie), DC - Main circuit≤ 30 % (I/Ie)Relative symmetric net frequency tolerance10 %10.10 Temperature riseThe panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.Number of HW-interfaces (parallel)Assigned motor power at 230/240 V, 60 Hz, 1-phase3 HPInterfacesMax. total power consumption from AS-Interface® power supply unit (30 V): 250 mANumber of slave addresses: 31 (AS-Interface®) Specification: S-7.4 (AS-Interface®)Number of phases (input)3Eaton Corporation plc Eaton House30 Pembroke Road Dublin 4, Ireland © 2023 Eaton. Med enerett.Eaton is a registered trademark.All other trademarks are property of their respectiveowners./socialmedia36.6 W at 25% current and 0% speed 38.1 W at 25% current and 50% speed 42 W at 50% current and 0% speed 42.5 W at 50% current and 90% speed 44.2 W at 50% current and 50% speed 55.9 W at 100% current and 0% speed 58.3 W at 100% current and 90% speed 60.4 W at 100% current and 50% speed 0Above 1000 m with 1 % performance reduction per 100 m Max. 2000 mHeat dissipation at current/speed Number of interfaces (PROFINET)Altitude。
铝制螺栓齿速减器说明书
SKU No. Model No.
Ratio
Specifications
8607400 RV063F-60-3/4HP 60:1
Max. Input HP Max. Torque Output (in-lb) Hollow Input Shaft Dia. (in.) Hollow Output Shaft Dia. (in.) Max. Input Shaft Speed (RPM) Efficiency C-face mounting
Preparing the Area Clean the work area until it is free of debris and dust before disassembling the Reducer. Contaminates can adhere to oil coating the parts and may damage the mechanism. Have a clean container ready to place the parts during the disassembly process. Tools Required • 6mm Allen Wrench • Torque Wrench When this manual refers to a part name, please refer to the Exploded Parts View on Page 2.
5/8"
1-1/8" E
G 3.35
I F
SKU No. 8607400
SKU No. 8607400
MODEL No. RV063F-60-3/4HP
RATIO 60 :1
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
H = VIH, L=VIL, X = Don't care.
DC ELECTRICAL CHARACTERISTICS (TA = 0℃ to 70℃)
PARAMETER Power Voltage Input High Voltage Input Low Voltage Input Leakage Current Output Leakage Current Output High Voltage Output Low Voltage Operating Power Supply Current Standby Current (TTL) Standby Current (CMOS) SYMBOL TEST CONDITION VCC VIH VIL ILI ILO VOH VOL ICC ISB ISB1 8 10/12/15 MIN. TYP. MAX. 3.15 3.3 3.6 3.0 3.3 3.6 2.0 VCC+0.3 -0.3 0.8 -2 2 -2 2 2.4 0.4 150 120 100 80 3 10 1 3
2
UTRON
Rev. 1.0
128K X 8 BIT HIGH SPEED CMOS SRAM
UT61L1288
ABSOLUTE MAXIMUM RATINGS*
PARAMETER Terminal Voltage with Respect to Vss Operating Temperature Commercial Storage Temperature Power Dissipation DC Output Current Soldering Temperature (under 10 secs) SYMBOL VTERM TA TSTG PD IOUT Tsolder RATING -0.5 to 4.6 0 to 70 -65 to 150 1 50 260 UNIT V ℃ ℃ W mA ℃
Note : These parameters are guaranteed by device characterization, but not production tested.
AC TEST CONDITIONS
Input Pulse Levels Input Rise and Fall Times Input and Output Timing Reference Levels Output Load 0V to 3.0V 3ns 1.5V CL=30pF, IOH/IOL= -4mA / 8mA
UT61L1288
FEATURES
Fast access time : 8ns for Vcc=3.15V~3.6V 10/12/15ns for Vcc=3.0V~3.6V CMOS low power operating : Operating current : 150mA (max.) Standby current : 1mA (Typ.) Single 3.15~3.6V power supply Operating temperature : Commercial : 0℃~70℃ All TTL compatible inputs and outputs Fully static operation Three state outputs Package : 32-pin 8mm x 13.4mm STSOP
The UT61L1288 is a 1,048,576-bit high-speed CMOS static random access memory organized as 131,072 words by 8 bits. The UT61L1288 operates from a single 3.15~3.6V power supply and all inputs and outputs are fully TTL compatible. It is fabricated using high performance, high reliability CMOS technology.
_________________________________________________________________________________________________ UTRON TECHNOLOGY INC. P80077 1F, No. 11, R&D Rd. II, Science-Based Industrial Park, Hsinchu, Taiwan, R. O. C. TEL: 886-3-5777882 FAX: 886-3-5777919
TRUTH TABLE
MODE Standby Output Disable Read Write
Note:
CE H L L L
OE X H L X
WE X H H L
I/O OPERATION High - Z High - Z DOUT DIN
SUPPLY CURRENT ISB,ISB1 ICC ICC ICC
UNIT V V V V µA µA V V mA mA mA mA mA mA
* ISB1< 1mA for special order or requirement.
UTRON TECHNOLOGY INC. 1F, No. 11, R&D Rd. II, Science-Based Industrial Park, Hsinchu, Taiwan, R. O. C. TEL: 886-3-5777882 FAX: 886-3-5777919
Rev. 1.0
___________________________________________________________________________________________________________
128K X 8 BIT HIGH SPEED CMOS SRAM GENERAL DESCRIPTION
*
VSS ≦VIN ≦VCC VSS ≦VI/O ≦VCC; Output Disable IOH= -4mA IOL= 8mA Cycle time=min, 100%duty 8 10 I/O=0mA, CE =VIL 12 15 CE =VIH, other pins =VIL or VIH CE =VCC-0.2V, other pins at 0.2V or Vcc-0.2V
UTRON
Rev. 1.0
128K X 8 BIT HIGH SPEED CMOS SRAM
UT61L1288
REVISION HISTORY
REVISION DESCRIPTION Preliminary Rev. 0.1 Original. 1.Revised CMOS low power operating : Rev. 1.0 Operating current : 195 150mA (max.) Standby current : 30mA (max.) 1mA(Typ.) 2.Revised power supply : 3.0~3.6V 3.15~3.6V 3.Revised DC CHARACTERISTICE ICC –8ns (max) : 200 150mA ICC –10ns (max) : 195 120mA ICC –12ns (max) : 190 100mA ICC –15ns (max) : 150 80 mA ISB (max) : 30 10mA, ISB (typ) : NA 3mA ISB1 (max) : 10 3mA, ISB1 (typ) : NA 1mA ISB1 (max)<1 mA for special order 4. Add order information for lead free product Date Jan 2,2002 May 20,2003
UTRON TECHNOLOGY INC. 1F, No. 11, R&D Rd. II, Science-Based Industrial Park, Hsinchu, Taiwan, R. O. C. TEL: 886-3-5777882 FAX: 886-3-5777919
P80077
1
UTRON
AC ELECTRICAL CHARACTERISTICS (TA = 0℃ to 70℃)
(1) READ CYCLE
PARAMETER Read Cycle Time Address Access Time Chip Enable Access Time Output Enable Access Time Chip Enable to Output in Low Z Output Enable to Output in Low Z Chip Disable to Output in High Z Output Disable to Output in High Z Output Hold from Address Change UT61L1288 UT61L1288 UT61L1288 UT61L1288 -8 -10 -12 -15 SYMBOL VCC=3.15〜3.6 VCC=3.0〜3.6 VCC=3.0〜3.6 VCC=3.0〜3.6 MIN. MAX. MIN. MIN. MIN. MAX. MIN. MAX. tRC 8 10 12 15 tAA 8 10 12 15 tACE 8 10 12 15 tOE 4 5 6 7 tCLZ* 3 3 3 3 tOLZ* 0 0 0 0 tCHZ* 4 5 6 7 tOHZ* 4 5 6 7 tOH 3 3 3 3 UNIT ns ns ns ns ns ns ns ns ns