Platform Guide:VIPRION 2400
MAN-0344-02
Table of Contents Table of Contents
Legal Notices (7)
Chapter 1: The VIPRION 2400 platform (9)
About the chassis (10)
About the blades (11)
USB LCD module (11)
Using the USB LCD module (12)
About LCD menus (13)
Indicator LEDs (14)
Chassis standard operating states (14)
Blade indicator LED types (14)
Blade LED status conditions (15)
Fan tray indicator LED types (15)
Power supply indicator LED types (15)
Indicator LED behavior (16)
LED alert conditions (16)
Defining custom alerts (16)
Additional indicator LED status conditions (17)
Platform interfaces (17)
About blade interfaces (17)
Optical transceiver specifications (21)
Always-On Management (24)
AOM Command Menu options (24)
Accessing the AOM Command Menu from the serial console (25)
Capturing a blade console (25)
Chapter 2: Platform Installation (27)
General recommendations for rack mounting (28)
Components provided with the chassis (28)
Components provided with blades (28)
Peripheral hardware that you provide (29)
Unpacking the chassis (29)
About installing the chassis (30)
About the front-mounting kit (31)
About the four-point rack mounting kit (32)
Installing the cable management system (33)
About powering the VIPRION 2400 AC platform (34)
Powering the AC platform (35)
3
Table of Contents
About powering the VIPRION 2400 DC platform (36)
About installing blades (36)
Installing a blade (37)
Removing a blank (38)
Removing a blade (38)
Connecting the cables and other hardware (39)
About cluster management (40)
Configuring the cluster IP address from the LCD (41)
Configuring the cluster IP address using the config utility (42)
Configuring the cluster IP address using tmsh (43)
Licensing the platform (43)
Verifying blade availability (43)
Chapter 3: Platform Maintenance (45)
About AC power supplies (46)
Removing a power supply (46)
Installing an AC power supply (47)
About DC power supplies (48)
Removing a power supply (48)
Installing a DC power supply (49)
Wiring the DC connector (50)
Powering the DC platform (51)
About the fan tray (52)
Replacing the fan tray (53)
About the hard drive assembly (54)
Replacing a hard drive assembly (54)
Appendix A: Environmental Guidelines (57)
General environmental guidelines (58)
Guidelines for AC-powered equipment (59)
Guidelines for DC-powered equipment (60)
Guidelines for VIPRION Series DC platform installation (60)
Appendix B: Platform Airflow (61)
Platform Airflow Diagram (62)
Appendix C: Platform Specifications (63)
General specifications for system features (64)
Blade hardware specifications (64)
Chassis hardware specifications (65)
Chassis operating specifications (66)
4
Table of Contents
AC power requirements (66)
AC power cables (66)
AC power redundancy provisioning (67)
AC platform power consumption (low-line input) (67)
AC platform power consumption (high-line input) (68)
DC power requirements (68)
DC platform power consumption (68)
Safety requirements (69)
EMC requirements (69)
Acoustic, airflow, and altitude specifications (70)
Appendix D: China RoHS Requirements (73)
Hazardous Substance Levels for China (74)
Appendix E: Repackaging Guidelines (77)
Repackaging the chassis (78)
Repackaging a blade (79)
5
Table of Contents 6
Legal Notices
Publication Date
This document was published on February 8, 2012.
Publication Number
MAN-0344-02
Copyright
Copyright © 2012, F5 Networks, Inc. All rights reserved.
F5 Networks, Inc. (F5) believes the information it furnishes to be accurate and reliable. However, F5 assumes
no responsibility for the use of this information, nor any infringement of patents or other rights of third
parties which may result from its use. No license is granted by implication or otherwise under any patent,
copyright, or other intellectual property right of F5 except as specifically described by applicable user
licenses. F5 reserves the right to change specifications at any time without notice.
Trademarks
3DNS, Access Policy Manager, Acopia, Acopia Networks, Advanced Client Authentication, Advanced
Routing, APM, Application Security Manager, ARX, AskF5, ASM, BIG-IP, Cloud Extender, CloudFucious,
CMP, Data Manager, DevCentral, DevCentral [DESIGN], DNS Express, DSC, DSI, Edge Client, Edge
Gateway, Edge Portal, EM, Enterprise Manager, F5, F5 [DESIGN], F5 Management Pack, F5 Networks,
F5 World, Fast Application Proxy, Fast Cache, FirePass, Global Traffic Manager, GTM, IBR, Intelligent
Browser Referencing, Intelligent Compression, IPv6 Gateway, iApps, iControl, iHealth, iQuery, iRules,
iRules OnDemand, iSession, IT agility. Your way., L7 Rate Shaping, LC, Link Controller, Local Traffic
Manager, LTM, Message Security Module, MSM, Netcelera, OneConnect, Packet Velocity, Protocol
Security Module, PSM, Real Traffic Policy Builder, Scale N, SSL Acceleration, StrongBox, SuperVIP, SYN
Check, TCP Express, TDR, TMOS, Traffic Management Operating System, TrafficShield, Transparent
Data Reduction, VIPRION, vCMP, W A, W AN Optimization Manager, WANJet, WebAccelerator, WOM,
and ZoneRunner, are trademarks or service marks of F5 Networks, Inc., in the U.S. and other countries,
and may not be used without F5's express written consent.
All other product and company names herein may be trademarks of their respective owners.
Export Regulation Notice
This product may include cryptographic software. Under the Export Administration Act, the United States
government may consider it a criminal offense to export this product from the United States.
RF Interference Warning
This is a Class A product. In a domestic environment this product may cause radio interference, in which
case the user may be required to take adequate measures.
FCC Compliance
This equipment has been tested and found to comply with the limits for a Class A digital device pursuant
to Part 15 of FCC rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This unit generates, uses, and
Legal Notices
can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual,
may cause harmful interference to radio communications. Operation of this equipment in a residential area
is likely to cause harmful interference, in which case the user, at his own expense, will be required to take
whatever measures may be required to correct the interference.
Any modifications to this device, unless expressly approved by the manufacturer, can void the user's authority
to operate this equipment under part 15 of the FCC rules.
Canadian Regulatory Compliance
This Class A digital apparatus complies with Canadian ICES-003.
Standards Compliance
This product conforms to the IEC, European Union, ANSI/UL and Canadian CSA standards applicable to
Information Technology products at the time of manufacture.
VCCI Class A Compliance
This is a Class A product. In a domestic environment, this product may cause radio interference, in which
case the user may be required to take corrective actions. VCCI-A
8
Chapter 1The VIPRION 2400 platform The VIPRION ®2400 platform provides you with the flexibility and feature-rich capabilities of F5 products on a powerful and Topics:
•About the chassis
highly-extensible hardware platform. With this platform, you install •About the blades
and configure multiple F5 products using blades that are hot-swappable, which provides you with the ability to add, remove,•USB LCD module
or change the platform’s configuration to best fit your network.•Indicator LEDs
Everything is available for you to add, remove, or change including the blades, power supplies, fan tray, and more.
•Platform interfaces
•Always-On Management The platform includes two primary components: the chassis, which houses the components, and blades, which reside within the chassis and provide the hardware and software needed to manage network traffic.
The VIPRION 2400 Series platform supports either AC or DC power. If you ordered DC power as a factory option, the platform comes pre-installed with DC power supplies. If you ordered DC power supplies from F5 Networks as an upgrade to an AC-powered platform, you have to switch out the AC power supplies for DC power supplies.
Although the VIPRION 2400 platform is highly extensible and designed to be easy to implement, familiarity with the platform components can help ensure that you install and integrate the platform successfully and effectively.
About the chassis The chassis is the housing unit that contains all of the components necessary for the VIPRION 2400 platform to operate effectively. One of the most powerful features of the VIPRION 2400 platform is that you can add, remove, or change any or all of the essential components of the platform. These components include blades, power supplies, and the fan tray. This configuration allows for an extremely robust and flexible system that can manage large amounts of application traffic, and remain operational even if one of its
components goes offline.1.Power supply 12.Power supply 23.Blades (1-4)Figure 1: Front view of a VIPRION 2000 Series chassis with four blades
The fan tray is on the back of the chassis.Figure 2: Back view of the chassis 10The VIPRION 2400 platform
About the blades
A blade is the primary component that handles the traffic management within the VIPRION 2400 platform.
You can install up to four blades in a VIPRION 2400 chassis. These blades comprise a group, known as a
cluster. The chassis includes blanks in the slots where blades are not installed. Blanks must be installed in
all unused slots, as they help ensure proper airflow within the chassis and EMC compliance of the unit.
1.Captive screws
2.SFP+ ports
3.Console port
4.Serial (hard-wired) failover port
5.Management port
B ports
7.Indicator LEDs
Figure 3: Front view of the B2100 blade
USB LCD module
An external USB LCD module is available for use with the VIPRION 2000 Series platform. You can use
the USB LCD module to configure and manage the unit without attaching a console or network cable.
Note: The USB LCD module is an optional device that is not included with the platform by default.
Figure 4: USB LCD module
Note: The USB LCD module works only with the VIPRION 2000 Series platform.
Using the USB LCD module
1.Insert the plug into one of the two USB ports located on the front of the primary blade.
The USB LCD module powers on and displays BIG-IP® software information.
2.Press the Check button to clear any alerts on the LCD screen.
You must clear any alerts on the screen before you can use the LCD module.
3.Press the X button to put the LCD in Menu mode.
The Left Arrow, Right Arrow, Up Arrow, and Down Arrow buttons are functional only when the LCD
is in Menu mode.
Pausing on a screen
Normally, the screens cycle on the LCD module at a constant rate, but you can pause on a specific screen.
Push the Check button to toggle the LCD screen between Hold and Rotate modes.
In Hold mode, a single screen is displayed. The Rotate mode changes the screen displayed on the LCD
every four seconds.
Clearing alerts
Press the Check button to clear any alerts on the LCD screen.
You must clear any alerts on the screen before you can use the LCD module.
About LCD menus
There are three menus on the LCD module. You can configure the display options to meet your needs.
Options menu
You can use the Options menu to adjust the display properties of the LCD module.
Description
Option Turns on (checked) or off (unchecked) the heartbeat panel on the LCD. This heartbeat does not affect the failover mechanism of the system.
Heartbeat
Specifies an LCD screen backlighting option. Select from the following options:Backlight
•ON enables the backlight.
•GRAY enables the software to specify when the backlight is illuminated.

OFF disables the backlight.
Sets the contrast of the LCD.Contrast Adjusts LCD backlight brightness.
On Brightness Controls the brightness of the LCD when the backlight is off.
Off Brightness
Screens menu
You can use the Screens menu to specify the information that is displayed on the default screens.
Description
Option Displays the date and time.
DateScreen Displays the information screen Screen Displays product version information.
VersionScreen
System menu
You can use the System menu to configure the management interface on both clusters and blades. This menu also provides various options for the hardware.
Suboptions Description
Option Cluster Mgmt
Select from the following suboptions:Configures the cluster IP address,netmask, and default gateway for managing the cluster.
Cluster
•Cluster IP - Configure the cluster IP address.
•Cluster IP Mask - Configure the netmask.

Gateway - Configure the default gateway for managing the cluster.
Suboptions Description Option •
Commit - Save your changes.
Cluster Mbrs Select from the following suboptions:
Configures the management IP addresses of the blades within the cluster.

Blade [1-4] Mgmt •
Blade Mgmt IP - Configure the management IP address of the selected blade within the cluster.•
Commit - Save your changes.
Indicator LEDs
The VIPRION 2400 platform includes indicator LEDs in three locations: on the individual blades, on the power supplies, and on the fan tray.
Chassis standard operating states
When the platform is in a standard operating state, the LEDs behave in a defined manner.Alarm LED Status LED Secondary LED Primary LED System State Off/None Green solid Off/None Off/None Active mode Off/None
Off/None
Off/None
Off/None
Powered off
Blade indicator LED types
The blade LEDs indicate whether the blade is a primary or secondary blade, and show alarm and blade status.Description
Function Indicates that the blade is a primary blade for a cluster.Primary Indicates that the blade is a secondary blade for a cluster.Secondary Indicates the state of the system: Active/Standalone (green) or Standby (yellow).
Status Indicates a non-specific alert level. Use SNMP traps, system logs,or the LCD display for more information.
Alarm
Blade LED status conditions
When a blade is shut down, reset, or not properly seated, the blade LEDs behave in a defined manner.
Blade State
Primary LED
Secondary LED
Alarm LED
Status LED
User initiated blade power
Green blinking
Off/None
Green blinking
Green blinking
down
Blade shut down due to
Yellow blinking
Red solid
Yellow blinking
Yellow blinking
thermal overtemp limit
Yellow blinking
Blade not seated properly
Yellow blinking
Red solid
Yellow solid
Fan tray indicator LED types
The indicator LED on the fan tray displays information about the status of the fan tray.
LED action
Fan tray status
Yellow solid
Indicates that the fan tray controller is powering on.
Green solid
Indicates that the fan tray controller is fully functional and all fans
are spinning within the specified RPMs.
Yellow solid
Indicates if any of the fans are not spinning within the specified RPM
range.
Power supply indicator LED types
There are several indicator LEDs on the power supply. Each LED provides a specific function.
Function
Description
AC
Indicates that AC input voltage is operational (on) or non-functioning
(off).
DC
Indicates that DC output voltage is operational (on) or
non-functioning (off).
Indicates the following conditions:
FAIL
•No AC input
•Fan failure
•Power supply errors or failures (for example, high temperature,
high voltage)
SYS
Indicates the following conditions:
•Yellow status when the fan tray is powered, and one of the
following conditions is true:
•AC failure
•DC failure
•Any other power supply faults, such as fan failure (indicated
by the FAIL LED)
Description
Function
•Green status when the fan tray is powered, and the power supply
is fully functional (AC and DC are OK; no other faults indicated
by the FAIL LED).
Indicator LED behavior
The indicator LEDs behave in a specific manner to indicate system or component status.
Behavior
Description
Off (none)
LED is not lit and does not display any color.
Solid
LED is lit and does not blink.
Blinking
LED turns on and off at a regular frequency.
Intermittent
LED turns on and off with an irregular frequency and might
sometimes appear solid.
LED alert conditions
When there is an alert condition on the unit, the Alarm LED behaves in a specific manner.
Action
Description
System situation
Alarm LED behavior
Emergency
Red blinking
Alert or Critical
Red solid
Error
Yellow blinking
Yellow solid
Warning
Defining custom alerts
The /etc/alertd/alert.conf and the /config/user_alert.conf files on the VIPRION
system define alerts that cause the indicators to change. The /etc/alertd/alert.conf file defines
standard system alerts, and the /config/user_alert.conf file defines custom settings. You should
edit only the /config/user_alert.conf file.
1.Open a command prompt on the VIPRION system.
2.Type the following command:
cd /config
ing a text editor, such as vi or Pico, open the /config/user_alert.conf file.
4.Add the following lines to the end of the file:
alert BIGIP_MCPD_MCPDERR_POOL_MEMBER_MON_DOWN "Pool member (.*?):(.*?)
monitor status down."
{
snmptrap OID=".1.3.6.1.4.1.3375.2.4.0.10";
lcdwarn description="Node down" priority="1"
}
alert BIGIP_MCPD_MCPDERR_NODE_ADDRESS_MON_DOWN "Node (.*?) monitor
status down." {
snmptrap OID=".1.3.6.1.4.1.3375.2.4.0.12";
lcdwarn description="Node address down" priority="1"
}
alert BIGIP_MCPD_MCPDERR_POOL_MEMBER_MON_UP "Pool member (.*?):(.*?)
monitor status up."
{
snmptrap OID=".1.3.6.1.4.1.3375.2.4.0.11"
}
alert BIGIP_MCPD_MCPDERR_NODE_ADDRESS_MON_UP "Node (.*?) monitor status
up."
{
snmptrap OID=".1.3.6.1.4.1.3375.2.4.0.13"
}
5.Save the file and exit the text editor.
The front panel LEDs now indicate when a node is down.
Additional indicator LED status conditions
A few LED status conditions are not covered in the definition tables in the /etc/alertd/alert.conf
file.
Yellow intermittent Status LED indicator
A yellow intermittent Status LED indicates that the unit is not under host computer control. This might be
due to the host being halted or due to a software or hardware problem that interferes with the host’s control
of the LED.
Green/Yellow solid Status LED indicator
When the Status LED indicator is solid yellow or green, it indicates that the system is in a Standby state
(yellow) or an Active state (green). It displays solid green if the unit is Standalone or if it is the Active unit
of a redundant system configuration. It displays yellow if the unit is the Standby member of a redundant
system configuration.
Platform interfaces
Every platform includes multiple interfaces. The exact number of interfaces that are on the system depends
on the platform type.
Each interface on the platform has a set of properties that you can configure, such as enabling or disabling
the interface, setting the requested media type and duplex mode, and configuring flow control.
About blade interfaces
The B2100 blades have eight 10GbE SFP+ optic interfaces that are connected internally. The SFP+ connectors
can each support 10G speed with an F5-branded optic SFP+ module or 1000 Mbit speed with an F5-branded
optic SFP 1GbE module optic module installed.
Viewing the status of a specific interface using tmsh
You can use tmsh to view the status of a specific interface on a platform.
1.From the system prompt, type the following to open tmsh:
tmsh
The following prompt displays: user@bigip01(Active)(/Common)(tmos)#.
2.Type the following to navigate to the network module:
net
The following prompt displays: user@bigip01(Active)(/Common)()#.
e the following syntax to display the current status of a specific interface:
show interface <interface_key>
The following is an example of the output you might see when you issue this command on interface
1.2:
---------------------------------------------------------
Net::Interface
Name Status Bits Bits Errs Errs Drops Drops Colli
In Out In Out In Out sions
---------------------------------------------------------
1.2 up 191.4K 0 0 0 374 0 0
Viewing the status of all interfaces using tmsh
You can use tmsh to view the status of all interfaces on the platform.
1.From the system prompt, type the following to open tmsh:
tmsh
The following prompt displays: user@bigip01(Active)(/Common)(tmos)#.
2.Type the following to navigate to the network module:
net
The following prompt displays: user@bigip01(Active)(/Common)()#.
e the following syntax to display the current status of all interfaces:
show interface
The following is an example of the output you might see when you issue this command:
------------------------------------------------------------
Net::Interface
Name Status Bits Bits Errs Errs Drops Drops Colli
In Out In Out In Out sions
------------------------------------------------------------
1.1 down 0 0 0 0 0 0 0
1.2 up 191.4K 0 0 0 374 0 0
1.3 down 0 0 0 0 0 0 0
1.4 up 2
2.5K 0 0 0 44 0 0
2.1 miss 0 0 0 0 0 0 0
2.2 miss 0 0 0 0 0 0 0
mgmt up 43.2G 160.0G 0 0 0 0 0
About interface media type and duplex mode
All interfaces on the system default to auto-negotiate speed and duplex settings. We recommend that you
also configure any network equipment that you plan to use with the system to auto-negotiate speed and
duplex settings. If you connect the system to network devices with forced speed and duplex settings, you
must force the speed and duplex settings of the system to match the settings of the other network device.
Important: If the system is attempting to auto-negotiate interface settings with an interface that
has the speed and duplex settings forced (that is, auto-negotiation is disabled), you will experience
severe performance degradation. This applies to 10GbE and 40GbE interfaces.
By default, the media type on interfaces is set to automatically detect speed and duplex settings, but you
can specify a media type as well. Use the following syntax to set the media type:
tmsh modify net interface <interface_key> media <media_type> | auto
If the media type does not accept the duplex mode setting, a message appears. If media type is set to auto,
or if the interface does not accept the duplex mode setting, the duplex setting is not saved to the
/config/bigip_base.conf file.
Important: If you manually configure the platform to use specific speed and duplex settings on
interfaces, Auto-MDI/MDIX functionality is disabled by default. When an interface is set manually,
it functions as a data terminal equipment (DTE) port. This means that crossover cables are required
to connect to other DTE devices (such as servers), and straight-through cables are required for
connecting to data communications equipment (DCE) devices (for example, switches or routers).
Be sure to use the correct cable type (straight-through or crossover) if you manually set interface
speed and duplex settings.
Important: Starting with BIG-IP software versions 9.4.8 and 10.1.0, Auto-MDI/MDIX functionality
is retained when you manually configure an interface to use specific speed and duplex settings.
With these versions of the BIG-IP system, you can use either a straight-through cable or a crossover
cable when media settings are forced, and you will be able to successfully link to either DTE or
DCE devices.
Valid media types
The following table lists the valid media types for the tmsh interface command.
Note: This platform might not support all of the media type options that are available in tmsh.
10BaseT half
100BaseTX full
10BaseT full
1000BaseLX full
10GBaseER full
1000BaseCX full
10GBaseLR full
1000BaseT half
10GBaseSR full
1000BaseT half
10GBaseT full
1000BaseSX full
10SFP+Cu full
auto
40GBaseSR4 full
none
40GBaseLR4 full
no-phy
100BaseTX half
Viewing valid media types for an interface
You can use tmsh to view the valid media types for an interface.
Note: This platform might not support all of the media type options that are available in tmsh .
1.From the system prompt, type the following to open tmsh :tmsh
The following prompt displays: user@bigip01(Active)(/Common)(tmos)#.2.Type the following to navigate to the network module:net
The following prompt displays: user@bigip01(Active)(/Common)()#e the following syntax to display the valid media types for a specific interface:
show running-config interface <interface_key> media-capabilities
Important: In all Gigabit Ethernet modes, the only valid duplex mode is full duplex.
The following is an example of the output you might see when you issue this command on interface 1.3:
net interface 1.3 {
media-capabilities { none auto 10T-FD 10T-HD 100TX-FD 100TX-HD 1000T-FD 1000T-HD }}
Network interface LED behavior
The appearance and behavior of the network interface LEDs on the blades indicate network traffic activity,interface speed, and interface duplexity.
SFP+ port LED behavior
The appearance and behavior of the SFP+ optic interface LEDs indicate network traffic activity, interface speed, and interface duplexity.
Activity LED Speed LED Link Blade type Not lit Not lit No link
B2100Not supported Not supported 1Gbit/s, half duplex B2100Green (with traffic)Yellow solid 1Gbit/s, full duplex B2100Not supported Not supported 10Gbit/s, half duplex B2100Green (with traffic)
Green solid
10Gbit/s, full duplex
B2100
Optical transceiver specifications
Specifications for fiber SFP modules
This table lists specifications for the available fiber Gigabit Ethernet SFP (or Mini-GBIC) transceiver modules.
Important: You must ensure suitability of both the optical fiber and the laser transceiver on the
other end.
Important:
Fiber cables must be a minimum of two meters, according to IEEE Std 802.3ae.Note: F5 Gigabit Ethernet modules comply with IEEE standards 802.3ab (1000BASE-T) and 802.3z
(1000BASE-SX, 1000BASE-LX).Supported platforms Operating distance/cable specifications
Connector type Laser emitter Module 1500, 1600,3400, 3600,LC
850 nm
(multi-mode)
1000Base-SX (Short Range)Ethernet Transceiver

220 meters maximum of
62.5um MMF that meets type A1a defined in IEC 60793-2:1992
3900, 6400,6800, 6900,8400, 8800,•
500 meters maximum of
50.0um MMF that meets type 8900, 8950,11050,VIPRION ®A1b defined in IEC 60793-2:1992
1500, 1600,3400, 3600,LC
1310 nm
(single-mode)
1000Base-LX (Long Range)Ethernet Transceiver

5 kilometers maximum using 10um SMF that meets type B1in IEC 60793-2:1992
3900, 6400,6800, 6900,8400, 8800,•
550 meters maximum using 50um MMF that meets type 8900, 8950,A1b defined in IEC 60793-2:1992
11050,VIPRION

550 meters maximum using 62.5um MMF that meets type A1a defined in IEC 60793-2:1992
Note: When using MMF ,single-mode, fiber offset-launch
mode-conditioning patch cords are required in both ends of the link, as specified in IEEE 802.3-2005 section 38.11.4.
21
Platform Guide:VIPRION 2400。