BUSSMANN熔断器产品手册

合集下载

美国Eaton公司Bussmann系列Fusetron燃烧保护时延短筒熔断器说明说明书

美国Eaton公司Bussmann系列Fusetron燃烧保护时延短筒熔断器说明说明书

23% more energy efficient than the next leading brandBussmann series Fusetron fuses provide advanced protection time-delay fuse. Product description: Eaton’s Bussmann™ series Fusetron™fuses are, on average, 23% more energy efficient than the next leading brand, savingusers money*. The energy efficient RK5 fuses utilize a separate overload element to provide the best time-delay performance for sizing as close as 125% of motor Full Load Amps (FLA). Fusetron, 225-600 amp fuses enhance safety with insulated end caps to reduce exposure to live parts and extend air gap distance between blades of adjacent mounted fuse or to housing.Features and benefits:• Dual-element featureprovides the besttime-delay performance,allowing closer sizingand superior protectionof motors andtransformers.• Closer sizing allows forsmaller fuses and lesscostly switches.• 200kA interrupting ratingallows use in a broadrange of applications.• Most common fusesare in stock and readyto ship within 24 hourswith QuikShip EverydayService.Time-delay Fusetron fuses are ideallysuited for protecting motor andtransformer loads.* T est results are based on weightedsales volume of Fusetron andFerraz Shawmut (Mersen) fuses byselected amp and volt ratingcombination. Next leading brandrefers to Ferraz Shawmut basedon third-party fuse market sharedata for a twenty-seven monthperiod (July 2008 throughSeptember 2010).SERIESFusetron™ advanced protection time-delay fusesEaton, Bussmann, Fuses Made Simple, Fusetron, Limitron and Low-Peak are valuable trademarks of Eaton in the US and other countries. You are not permitted to use the Eaton trademarks without prior written consent of Eaton.CSA is a registered trademark of the Canadian Standards Group.UL is a registered trademark of the Underwriters Laboratories, Inc.Eaton1000 Eaton Boulevard Cleveland, OH 44122United States Bussmann Division 114 Old State Road Ellisville, MO 63021United States/bussmannseries © 2017 EatonAll Rights Reserved Printed in USAPublication No. 10117May 2017For Eaton’s Bussmann series product information,call 1-855-287-7626 or visit: /bussmannseries250V FRN-R Class RK5 dual-element, time-delay fuses Ratings•Volts• 250 Vac• 125 Vdc (1⁄10-60 A, 110-200 A)• 250 Vdc (225-600 A) •Amps• 1⁄10 to 600 A•IR• 200kA AC •20kA DC•Agency information•UL ® Listed, Std. 248-12, Class RK5, Guide JDDZ, File E4273, CSA ® Certified, Class 1422-01, File 53787, CE•Data sheet• No. 1019 (Up to 60 A) •No. 1020 (70-600 A)600V FRS-R Class RK5 dual-element, time-delay fuses Ratings•Volts• 600 Vac• 300 Vdc (1/10-30 A, 65-600 A)• 250 Vdc (35-60 A) •Amps• 1⁄10 to 600 A •IR• 200 kA AC, 20 kA DC•Agency information•UL Listed, Std. 248-12, Class RK5, Guide JDDZ,File E4273, CSA Certified, Class 1422-02s, File 53787, CE•Data sheet• No. 1017 (Up to 60 A)•No. 1018 (65-600 A)FRS-R-2FRS-R-10FRS-R-110FRS-R-1/8FRS-R-15/100FRS-R-2/10FRS-R-1/4FRS-R-3/10FRS-R-4/10FRS-R-1/2FRS-R-6/10FRS-R-8/10FRS-R-1FRS-R-1-1/8FRS-R-1-1/4FRS-R-1-4/10FRS-R-1-6/10FRS-R-1-8/10FRS-R-2-1/4FRS-R-2-1/2FRS-R-2-8/10FRS-R-3FRS-R-3-2/10FRS-R-3-1/2FRS-R-4FRS-R-4-1/2FRS-R-5FRS-R-5-6/10FRS-R-6-1/4FRS-R-7FRS-R-7-1/2FRS-R-8FRS-R-9FRS-R-12FRS-R-15FRS-R-17-1/2FRS-R-20FRS-R-25FRS-R-30FRS-R-35FRS-R-45FRS-R-50FRS-R-60FRS-R-70FRS-R-75FRS-R-80FRS-R-90FRS-R-100FRS-R-125FRS-R-150FRS-R-175FRS-R-225FRS-R-250FRS-R-300FRS-R-350FRS-R-400FRS-R-450FRS-R-500FRS-R-600—————FRS-R-2FRS-R-10FRS-R-100FRN-R-1/8FRN-R-15/100FRN-R-2/10FRN-R-1/4FRN-R-3/10FRN-R-4/10FRN-R-1/2FRN-R-6/10FRN-R-8/10FRN-R-1FRN-R-1-1/8FRN-R-1-1/4FRN-R-1-4/10FRN-R-1-6/10FRN-R-1-8/10FRN-R-2-1/4FRN-R-2-1/2FRN-R-2-8/10FRN-R-3FRN-R-3-2/10FRN-R-3-1/2FRN-R-4FRN-R-4-1/2FRN-R-5FRN-R-5-6/10FRN-R-6-1/4FRN-R-7FRN-R-7-1/2FRN-R-8FRN-R-9FRN-R-12FRN-R-15FRN-R-17-1/2FRN-R-20FRN-R-25FRN-R-30FRN-R-35FRN-R-45FRN-R-50FRN-R-60FRN-R-70FRN-R-75FRN-R-80FRN-R-85FRN-R-90FRN-R-110FRN-R-125FRN-R-150FRN-R-175FRN-R-225FRN-R-250FRN-R-300FRN-R-350FRN-R-400FRN-R-450FRN-R-500FRN-R-600—————Fuses Made Simple ™ is the easiest and fastest way to select and specify fusesUltimate protectionThe best worry-free protection in virtually any application. Low-Peak™ (yellow) fuses 50%*higher interrupting rating than any other similar fuse. Unique dual-element construction delivers a powerful combination of all performance options in one fuse - fast short-circuit protection, current limitation, and time-delay performance with up to 300kA interrupting ratings.Advanced protectionApplication specific protection for sensitive devices and critical components or motors and transformers.Limitron™ (black) fuses offer 10X better current limitation than basic circuit breakers or fuses**.Fusetron™ (green) fuses are 23% more energy efficient*** and the best time-delay performance.Based on the application, you can choose between fast short-circuit, current limiting performance of Limitron fuses or energy efficient, current limiting, time-delay performance of Fustron fuses and still get a 200kA interrupting rating.Basic protectionGeneral purpose (grey) delivers basic single-element fuse protection for service, feeder andbranch circuit applications. Featuring up to 50kA interrupting ratings.*50% higher IR (300 kA) than any other UL and CSA Class J, L and R fuses.**Does not include current limiting circuit breakers or current limiting fuses. Protection determined by comparing published let–through values for Class CC, J, R, and T fuses versus a RMS symmetrical waveform at 200kA.*** T est results are based on weighted sales volume of Fusetron and Ferraz Shawmut (Mersen) fuses by selected amp and volt rating combination. Next leading brand refers to Ferraz Shawmut based on third-party fuse market share data for a twenty-seven month period (July 2008 through September 2010).Four fuse familes in three tiers of protection offer distinct levels of performance benefits to help speed specification and selection:FRS-R-65Follow us on social media to get thelatest product and support information.。

布斯曼(Bussmann)系列保护级别简化选择手册说明书

布斯曼(Bussmann)系列保护级别简化选择手册说明书

Fuses Made Simple™The easiest and fastest way to select and specify the right fuseFuse selection made simpleFor more information visit /Bussmannseries/FusesMadeSimpleFuses Made Simple ™ with Bussmann ™ series fusesEach tier of protection offers distinct levels of performance benefits.Three tiers of protection help speed up specification and selectionFour fuse families make fuse selection and replacement easy• The Bussmann series QuikShip Everyday Service assures the most common part numbers are in stock and ship within 24 hours. In fact, 90% of our orders are shipped the same day.• Emergency and after-hours orders are possible with Bussmann series QuikShip Emergency Service. Orders are taken 24 hours a day, 365 days a year and product can be placed on the next flight out. Call 314-995-1342.QuikShip ™ Service - get the fuse you need, when you need it* 50% higher IR (300kA) than any other UL and CSA Listed Fuse. Includes Class J, L and R fuses.** Does not include current limiting circuit breakers or current limiting fuses. Protection determined by comparing published values for let–through for Class CC, J, R, and T fuses versus a symmetrical RMS waveform at 200kA.*** Test results are based on weighted sales volume of FUSETRON and Ferraz Shawmut (Mersen) fuses by selected amp and volt rating combination. Next leading brand refers to Ferraz Shawmut based on third-party fuse market share datafor a twenty-seven month period (July 2008 through September 2010).3Each fuse family is categorized by key protection characteristic and performance benefits.Ulitimate protection• Low-Peak ™ (yellow) - 50% more protection than any other listed fuse *Advanced protection• Fusetron ™ (green) - 23% more energy efficient *** and the best time-delay performance • Limitron ™ (black) - 10x better current limitation than basic circuit breakers or fuses **Basic protection• General purpose (gray) - Basic circuit protectionUlitimate protection – T he best worry-free protection in virtually any application. Unique dual-element construction delivers a powerful combination of all performance options in one fuse - fast short-circuit protection, currentlimitation, and time-delay performance with up to 300 kA interrupting ratings. Advanced protection – Application specific protection for sensitive devices and critical components or motors and transformers. Choose between fast short-circuit, current limiting performance or energy efficient, current limiting, time-delay performance based on the application. Featuring 200 kA interrupting ratings.Basic protection – Basic single-element protection for service, feeder and branch circuit applications. Featuring up to 100 kA interrupting ratings.For more information visit /Bussmannseries/FusesMadeSimpleFour fuse families5Delivers 50% more protection than any other listed fuse *Ultimate protection for any application• Industry’s only UL and CSA listed fuse with a 300 kA interrupting rating allows for simple, worry-free installation in virtually any application • Fast short-circuit protection and dual element, time-delay performance for ultimate protection • Consistent 2:1 coordination ratios for all Low-Peak fuses make selective coordination easy • Broad fuse family including Class CC, J, L, and R23% More Energy Efficient *** and the Best Time-Delay Performance *** Advanced protection and save more money• FUSETRON fuses are on average 23% more energy efficient than the next leadingbrand **• Dual-element feature provides the best time-delay performance • Allows for closer sizing to load and better equipment protection • Ideal for protection of motors and transformers • Class RK5 fuses with 200 kA interrupting rating10x better current limitation than basic circuit breakers or fuses **Advanced protection for sensitive devices and critical components• Provides short circuit protection that is on average 10x faster than basic circuit breakers or fuses ** • Fast-acting fuses help prevent equipment damage caused by short-circuit events • Ideal for critical components in industrial or commercial applications • Class CC, J, L, R and T fuses with 200 kA interrupting ratingBasic circuit protection Basic overcurrent protection• Meets basic NEC ®, CEC, UL and CSA requirements for service, feeder and branch circuit protection • Class H/K and G fuses with up to 100 kA interrupting ratingLow-PeakFusetronGeneral purposeLimitron* 50% higher IR (300kA) than any other UL and CSA Listed Fuse. Includes Class J, L and R fuses.** Does not include current limiting circuit breakers or current limiting fuses. Protection determined by comparing published values for let–through for Class CC, J, R, and T fuses versus a symmetrical RMS waveform at 200kA.*** Test results are based on weighted sales volume of FUSETRON and Ferraz Shawmut (Mersen) fuses by selected amp and volt rating combination. Next leading brand refers to Ferraz Shawmut based on third-party fuse market share datafor a twenty-seven month period (July 2008 through September 2010).For more information visit /Bussmannseries/FusesMadeSimpleService, feeder and branch circuit protection Interior lighting Distribution panels Disconnect switches Motor/motor control center Transformers Outdoor lighting Industrial and commercial applications2934567181118For more information visit /Bussmannseries/FusesMadeSimple7Advanced protectionLPS-RK-SP LPN-RK LP-CCFRN-R FRS-RFRS-R FRN-R CLASS RK5SC SCNON CLASS GKTU KLUKTS-R KTN-R JJN JJN JJS JJS CLASS T JKS FNQ-R KTK-RFor more information visit /Bussmannseries/FusesMadeSimpleEasy to find part numbersTo ensure you can easily find the part number when you need to replace fuses, the new label design has the part number located in multiple places of large body size blade fuses. With this updated look, you can easily find the important information regardless of the angle in which the fuse is installed.Part numberPart numberDate codeUPC scan informationAC voltage ratingDC voltage ratingAgency listingmarksFor more information visit /Bussmannseries/FusesMadeSimpleEnhance safety and relilability while reducing fuse inventoryLow-Peak Upgrade program9Enhance safety • Superior current-limitation helps reduce arc flash hazards.• Interrupting ratings up to 300kA for high fault currents.•Helps achieve code compliance with OSHA, NFPA ® and IEEE ®.Improve system reliability •Type 2 “no damage” motor starter protection reduces downtime.• Optional fuse indication to speed troubleshooting.•Easily meet selectivecoordination requirements with 2:1 amp ratio with any fuse in the Bussmann series Low-Peak family.Simplify inventory •One Bussmann series Low-Peak fuse can replace multiple fuses in a variety of applications.Eaton’s Bussmann series Low-Peak Upgrade program leverages our ultimate protection fuses to deliver enhanced safety, improved system reliability and a simplified inventory.With just three simple steps, it’s easier than ever to improve your circuit protection while reducing your fuse inventory and cost. What’s more, you’ll save time and increase productivity - all by using Low-Peak fuses.Let our team of experts walk you through the audit, analysis andimplementation of a Low-Peak Upgrade and start realizing savings today.Throughout the Bussmann series Low-Peak Upgrade process, you’ll have a dedicated team that includes a Bussmann series product authorized distributorand sales representative.Together, they will walk youthrough the three steps of the program, making it as easy and effortless for you as possible.For more information visit /Bussmannseries/FusesMadeSimpleComplementary productsThe broad portfolio of Bussmann series products include more than just UL low voltage fuses. Visit /bussmannseriesto learn more.Data signal surgeType 1 SurgePOD ™ surge protective devices DIN-Rail surge protective devices10For more information visit /Bussmannseries/FusesMadeSimple 11Customer careEmergency and after-hours ordersNext flight out or will call shipment for time-critical needs. Customers pay only standard product price, rush freight charges, and modest emergency service fee. Place these orders through the customer satisfaction team during regular business hours.• After-hours phone 314-995-1342Application engineering teamFUSETech, our team of application engineers is available to provide qualityanswers to your technical questions or concerns. When you need assistancewith Bussmann series products or solutions, give us a call or send us anemail. We are available Monday-Friday, 7:00 a.m. – 5:00 p.m. Central T ime.• Toll-free phone: 855-287-7626 (855-BUSSMANN)•E-mail:******************Provides real time product availability, net pricing, order status and shipment tracking. Log onto or call:•1-800-468-1705 option #3 for log-in assistanceOnline resourcesVisit /bussmannseries for the latest in new product introductions and more: • Product catalogs and profiles• Product data sheets• Application and technical referencesBussmann toolboxVisit T to access resources like:• Arcing current calculator• Available Fault Current Calculator (FC 2)• OSCAR 2.1 compliance software • RoHS compliance product search • SCCR Protection Suite • Selective Coordination Designer v1.0Customer satisfaction teamAvailable to answer questions regarding Bussmann series products and services Monday-Friday, 7:00 a.m. – 6:00 p.m. Central T ime.• Toll-free phone: 855-287-7626 (855-BUSSMANN)• Toll-free fax: 800-544-2570•E-mail:*********************Eaton, Bussmann, CUBEFuse, Fuses Made Simple, Fusetron, Limitron, Low-Peak, QuikShip and Quik-Spec are valuable trademarks of Eaton in the US and other countries. You are not permitted to use the Eaton trademarks without prior written consent of Eaton. CSA is a registered trademark of the Canadian Standards Group. NEC is a registered trademark of the National Fire Protection Association, Inc. UL is a registered trademark of the Underwriters Laboratories, Inc.Eaton 1000 Eaton Boulevard Cleveland, OH 44122United States Bussmann Division 114 Old State Road Ellisville, MO 63021United States /bussmannseries © 2017 Eaton All Rights Reserved Printed in USA Publication No. 10092March 2017Follow us on social media to get thelatest product and support information.For Eaton’s Bussmann series product information, call 1-855-287-7626 or visit:/bussmannseries。

Eaton Bussmann系列产品完整商品目录说明书

Eaton Bussmann系列产品完整商品目录说明书

A c c e s s o r i e sContentssupplemental (midget)2Fuse reducers — Class J, H(K) and RDummy fuse "neutrals" — 1/4" x 1-1/4", UL supplemental (midget), Class CC, H(K) and R 3Fuse pullers Fuse testers Spare fuse holders 4Spare fuse cabinet Tron™ clip clamps DIN-Rail adapterBussmann series accessories to fit your needsFuse reducers and dummy “neutrals”Reducers for Class J fuses (DFJ, JKS, LPJ)Carton quantity: 10 pairJ-131-30100J-1635-60100J-2635-60200†J-2170-100200†J-4170-100400†J-42††110-200400†J-62110-200600†J-64225-400600†† Not for bolt-on applications.†† N ot compatible with JKS fuses.Reducers for Class H(K) and R fuses Agency information•UL Listed, Guide IZZR, File E12853•CSA Certified, Class 6225-01, File 47235Carton quantity: 10 pairNO.213NO.216Up to 30100NO.216NO.61635-60100NO.226NO.62635-60200NO.2621NO.262170-100200NO.2641†NO.2641†70-100400NO.2642NO.2642110-200400NO.2661†NO.2661†70-100600NO.2662†NO.2662†110-200600NO.2664†NO.2664†225-400600* Single reducer only, pair not required.† Not CSA Certified.SAMI™ fuse coversSAMI (Safety And Maintenance Improvement) fuse covers help improve electrical safety by shielding a fuse that's mounted in an open style block. They are available in indicating and non-indicating versions for fuse Classes CC, G, H(K), J, RK1, RK5 and T , as well as UL supplemental (midget-type) fuses. Indicating feature requires a minimum of 90 V to illuminate lamp.One cover required for each pole. WARNING: To avoid electrical shock, turn power off before installing, removing or servicing.Agency information•UL Listed; SAMI-1I through SAMI-6I and SAMI-9I, SAMI-1N through SAMI-6N and SAMI-9N•UL Recognized; Guide JDVS2, File E58836, SAMI-7I and SAMI-7N •CSA Certified, Class 6225-01, File LR47235•CEFeatures•Insulated cover isolate fuses mounted in open blocks•Optional open fuse indicating light aids in system troubleshooting •Units are re-usable•Allows visual marking of lineside and loadside of fusesSAMI-1N** 5.021.031.94250 V , RK, K5, H (35-60 A)SAMI-2_600 V , RK, K5, H (0-30 A)7.031.30 2.07SAMI-3_600 V , J (65-100 A)7.031.30 2.33SAMI-5_600 V , RK, K5, H (35-60 A)8.201.30 2.18SAMI-6_600 V , J (35-60 A)4.981.17 2.14SAMI-7_600 V , Midget, Class CC, G (0-30 A) 3.820.751.72SAMI-9_250 V , RK, K5, H (0-30 A) 3.820.751.72600 V T (0-30 A)* For indicating cover, add suffix “I”, for non-indicating cover, add suffix “N,”example: SAMI-7I = Indicating, SAMI-7N = Non-indicating.** A vailable only as non-indicating.Trimming guides, no. 12041, 12042, 12043, 12045, 12046, 12049Data sheet no. 1204Data Sheet: 1118Dummy fuse “neutrals”Fuse pullersFuse pullers are available in various sizes to help safely and easily extract fuses from blocks and holders. They are only to be usedwhen the associated circuit has been de-energized.FP-31" to 1-3/4" diameter. fuses FP-41-3/4" to 2-1/2" diameter. fuses FP-6Up to 60 A Class T fuses FP-A3Glass tube and ATC fuses CFP-30CUBEFuse up to 30 ACFP-60CUBEFuse 35-60 AProbes slide to appropriate fuse length. Batteries are included and replaceable.WARNING:DO NOT test fuses while they are in the fuse panel.FT-3Blade fuse tester* Replacement battery is Rayovac 364 or equivalent.FP-2CFP_FP-A3FP-6FP-4FP-3FT-3Note: These are not fusesNNB-R —Class CC —NNC —1/4" x 1-1/4”—NTN-R-30250Class R/H Up to 30NTN-R-60250Class R/H 35-60NTN-R-100250Class R/H 70-100NTN-R-200250Class R/H 110-200NTN-R-400250Class R/H 225-400NTN-R-600250Class R/H 450-600NTS-R-30600Class R/H Up to 30NTS-R-60600Class R/H 35-60NTS-R-100600Class R/H 70-100NTS-R-200600Class R/H 110-200NTS-R-400600Class R/H 225-400NTS-R-600600Class R/H450-600NTN-R-60NNB NNB-RNTN-R-200Spare fuse cabinetSFC locking spare fuse cabinet measures 24" W x 30" H x 12" D and has five cubic feet of storage space. It's constructed of heavy 16 gauge steel with durable baked ASA 61 grey enamelfinish. Cabinet door is equipped with locking handle for security. Mounting holes are 16 inches oncenter with key slots.SFC-SHELF*Extra shelf for cabinet 2A1910-1Replacement key 2A1910-3Replacement lockData sheet no. 1119Spare fuse holdersTPSFH spare fuse holders are durably constructed using thermoplastic and feature common mounting using #6 screws or bolts on 5-inchcenters. With built-in retaining clips to secure fuses, these dovetailed/interlocking holders simplify installation and reduce hardware needs. Common footprint allows for anycombination of holders to be mounted together.5TPH spare fuse holder for Class CC and 13/32" diameter fuses is constructed ofthermoplastic with adhesive tape on back for easy mounting on cabinet doors without the need for extra hardware.Flammability rating: UL 94V0TPSFH-M 4TPM fuses TPSFH-LC 1TPL-C series fuses TPSFH-LB 1TPL-B series fuses TPSFH-N601TPN (35-60 A) fuses TPSFH-N304TPN (1-30 A) fuses TPSFH-AS 6TPA and TPS fuses TPSFH-T 10GMT fuses5TPH5Class CC and 13/32" diameter fusesData sheet no. 5014TRON™ clip clampsClip clamps are constructed with a phenolic knob and plated-steel jaws. They provide a means of tightening the contact between fuse block clips and the fuse and are available in various sizes for both ferrule and blade-typecartridge fuse clips.NO.225035-60600Up to 30NO.460035-60NO.5250/60070-100NO.6250/600110-200NO.7250/600225-400NO.8250/600450-600DIN rail adapterA DIN-Rail adapter permitssecure, positive snap-on mounting of up to 30 amps fuse blocks (1-, 2-, or 3-pole) onto various size rails to eliminates costly and time consuming drilling, tapping, and fastener mounting. The adapter mechanically locks into mounting holes of fuse blocks to form an integral part. One adapter is required for 1- and 2-pole blocks. Two adapters are required for 3-pole blocks.With the exception of the 32mm DIN-Rail, all block/adapterassemblies can be removed from a rail simply by pulling up on the release tab.Use of rail end-stops on both sides of adapters is recommended.DRA-115mm (Sym.)32mm (Asym.)DIN 35mm (Sym.)Black13/32" x 1-1/2"10x38mmG H (250 V)†J (30 A, 60 A*)R (250 V)†* Not applicable for new modular fuse blocks that have built-in 35mm DIN-Rail mount capability.† Mounting on 15mm rails is not recommended.Package quantities•Standard 10•Bulk 100 (Cat. No. BK/DRA-1)。

Bussmann系列钢筋固定熔断器说明书

Bussmann系列钢筋固定熔断器说明书

Stud-mounted fusesCatalog symbol: ACK-_ Description:Bussmann® series stud-mounted fuse.Specifications:Ratings• Volts - 130 Vdc (or less)• 130 Vdc - (10-100 A)• 72 Vdc - (120-200 A)• 48 Vdc - (225-300 A)• 80 Vdc - (400 A)• Amps - 10-400 A• Interrupting rating - 10 kAAgency information• UL® Recognized 15-300A, Guide JFHR2, File E56412Features:• These fuses avoid needless openings from starting currents or surges• A fuse link which operates only on very high overloads or short-circuits• Thermal cutout functions on low overloads – the thermal cutout cannot operate quickly at any load, hence long timelag is obtained on high overloads of short duration• This long time-lag also makes it unnecessaryto use extra large size or over-size fusesACK-15ACK-50ACK-120ACK-225 ACK-20ACK-60ACK-140ACK-250 ACK-25ACK-70ACK-150ACK-300 ACK-30ACK-75ACK-160ACK-400 ACK-35ACK-80ACK-175—Test specificationsACK300%35 Seconds*500%13 Seconds**Approximately.Recommended fuse blocks:ACK 35-603411ACK 225-4003578 ACK 70-1002322Dimensions - in (mm):ACK 10-30(63.5)(9.53)(12.70)(6.35)(14.15)(14.94)(0.79)ACK 35-60 3.0”(76.20)0.470”(11.94)0.685”(17.40)0.344”(8.74)0.812”(20.63)0.860”(21.84)0.051”(1.30)ACK 70-100 3.5”(88.90)0.547”(13.89)0.750”(19.05)0.312”(7.92)1.062”(26.98)1.15”(29.21)0.050”(1.27)ACK 120-200 3.750”(95.25)0.750”(19.05)0.750”(19.05)0.375”(9.52)1.062”(26.98)1.15”(29.21)0.050”(1.27)ACK 225-400 3.750”(95.25)0.610”(15.49)0.750”(19.05)0.312”(7.92)1.062”(1.062)1.125”(28.58)0.050”(1.27)Note: 10-60 amp fuses use brass terminals and ferrules.70-400 amp fuses use copper terminals and ferrules.2Technical Data 1040Effective June 2017/bussmannseries(63.5)(9.53)(12.70)(6.35)14.15)(14.94)(0.79)ACK 35-60 3.0”(76.20)0.470”(11.94)0.685”(17.40)0.344”(8.74)0.812”(20.63)0.860”(21.84)0.051”(1.30)ACK 70-100 3.5”(88.90)0.547”(13.89)0.750”(19.05)0.312”(7.92) 1.062”(26.98) 1.125”(28.58)0.050”(1.27)ACK 120-200 3.750”(95.25)0.750”(19.05)0.750”(19.05)0.375”(9.52) 1.062”(26.98) 1.15”(29.21)0.050”(1.27)ACK 225-4003.750”(95.25)0.610”(15.49)0.750”(19.05)0.312”(7.92)1.062”(1.062)1.125”(28.58)0.050”(1.27)Note: 10-60 amp fuses use brass terminals and ferrules. 70-400amp fuses use copper terminals and ferrules.Time-current curves – average meltStud-mounted fusesTechnical Data 1040Effective June 2017Stud-mounted fuses Follow us on social media to get the latest product and support information.For Eaton’s Bussmann series product information,call 1-855-287-7626 or visit:/bussmannseriesEaton and Bussmann are valuabletrademarks of Eaton in the US and other countries. You are not permitted to use theEaton trademarks without prior writtenconsent of Eaton.UL is a registered trademark of theUnderwriters Laboratories, Inc.Eaton1000 Eaton Boulevard Cleveland, OH 44122United States Bussmann Division 114 Old State Road Ellisville, MO 63021United States/bussmannseries © 2017 EatonAll Rights Reserved Printed in USAPublication No. 1040 – SB98107June 2017The only controlled copy of this data sheet is the electronic read-only version located on the Eaton network drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Eaton reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Eaton also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications.。

巴斯曼系列低档熔断器说明书

巴斯曼系列低档熔断器说明书

2023ContentsDescription P age Catalog symbol 2Description 2Specifications2Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2Number of poles . . . . . . . . . . . . . . . . . . . . . . . .2Agency information . . . . . . . . . . . . . . . . . . . . . .2Terminals and conductors . . . . . . . . . . . . . . . .2Terminal screw torque . . . . . . . . . . . . . . . . . . .2Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2Open fuse indication . . . . . . . . . . . . . . . . . . . . .2Ambient storage and operating temperature .2Flammability rating . . . . . . . . . . . . . . . . . . . . . .2Lockout/tagout provisions . . . . . . . . . . . . . . . . .2Circuit labeling provision . . . . . . . . . . . . . . . . .2Carton quantity . . . . . . . . . . . . . . . . . . . . . . . . .2Low Pro f ile Compact Circuit Protector (CCPLP)UL Class G, CC, and midget fused disconnect switchesDescription P age Features3Available Bussmann series fuses 3Catalog number tables4Class G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4Class CC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4UL midget . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4Dimensions5Panel mounting layout52Low Profile Compact Circuit Protector (CCPLP)UL Class G, CC, and midget f used disconnect switches/bussmannseriesTechnical Data 10372Effective July 2023Catalog symbol:•CCPLP -(poles)-(amps)-(terminal)Description:The revolutionary Bussmann ®series Low Profile Compact Circuit Protector (CCPLP) fused disconnect switch is available in 1-, 2- and 3-pole versions for UL ® Class CC (1/10-30A), Class G (20A), and 13/32”x1-1/2” midget UL (1/10-30A) fuses .The CCPLP has the smallest footprint of any UL 98 Listed fused disconnect switch along with up to a 200kA SCCR to help improve equipment SCCR .Class CC and G versions are easily selectively coordinated with the upstream Bussmann series CUBEFuse ™ using published fuse ampacity ratio tables .Unique panel mounting permits easy integration into many panel designs and provides a high SCCR alternative to low profile circuit breakers on the market .Specifications:Ratings•Frequency•50/60Hz•Impulse voltage•8kV•Volts•600Vac (Class CC up to 30A, Class G 20A)•240Vac (13/32” x 1-1/2” midget UL 30A)•Amps•Up to 30A (UL)•SCCR•200kA (Class CC)•100kA (Class G)•10kA (13/32”x1-1/2” midget UL)Poles• 1-, 2- and 3-pole factory configured•2- and 3-pole versions feature ganged switches and phase barriers .Agency information•Finger-safe IP20 from panel front •CE compliant •RoHS compliant•For Class G fuse versions•UL 98 Listed, File E302370, Guide WHTY •For Class CC fuse versions•UL 98 Listed, File E302370, Guide WHTY•cULus to CSA Standard 22 .2 No . 4-04, File E302370, Guide WHTY7•For UL midget f use versions•UL 508 Listed, File E320230, Guide NRNT•cULus Listed to CSA 22 .2 No . 14-05, File E320230, Guide NRNT7T erminals and conductors 75°C Cu•Screw terminal - #10-32 phil-slot screw with external tooth lock washer — use with properly rated/UL Listed ring or fork terminal•Pressure plate terminal - #10-32 phil-slot screw — single 22-6AWG solid or strandedT erminal screw torque•20 Lb-In (2.2 N•m)Mounting• Front panel mounting with customer supplied M3 screws •Mounting screw torque 4-5 Lb-In (0.4-0.5 N•m)Open fuse indication*•Local open fuse indication provided by a orange neon lamp on each pole, minimum voltage 90Vac*Open fuse indication requires an energized, closed circuit with an open fuse in the CCPLP and the switch in the ON position .Ambient storage and operating temperature•-20°C to 75°C, 85% relative humidity non-condensingFlammability rating•UL 94 V2Lockout/tagout provisions•Brady pin-out device, P/N 90844Circuit labeling provisions•Accepts up to two universal marker labels (P/N TM26CB)Carton quantity•12 poles (1-pole: 12 units, 2-pole: 6 units, 3-pole: 4 units)Minimumn enclosure size•6”x6”x4” per UL 98 Listing3Technical Data 10372Effective July 2023Low Profile Compact Circuit Protector (CCPLP)UL Class G, CC, and midget fused disconnect switches /bussmannseriesFeatures:•Suitable for global installations accepting UL Class G , CC, and midget fuses•Full voltage rated up to 600Vac•High Short-Circuit Current Ratings (SCCR) up to 200kA (UL) •Mounting and panel layout dimensions match common low-profile circuit breakers to provide an easy, alternative fused circuit protection solution .•Disconnect rated to provide means for load isolation •Extremely compact design at 19mm wide per pole•Class CC version is suitable for branch circuit disconnect and branch circuit protection•Local open fuse indication on each pole standard •Finger-safe IP20 from panel front for added safety•Built-in switch handle / fuse access door interlock prohibits removing the fuse under load•Lockout/tagout provisions made by using Brady pin-out device P/N 90844*Use Brady pin-out device, P/N 90844Circuit areaLockout/ tagout provision*Phase barrierAvailable Bussmann series fuses:CC current-limiting 600Vac 1023CC FNQ-R time-delay 600Vac 1014CC KTK-R fast-acting 600Vac 1015G SC time-delay (20A)600Vac 1024M FNM time-delay 250Vac 2028M FNQ time-delay 500Vac 1012M KTK fast-acting 600Vac 1011M BAF fast-acting 250Vac 2011MKLM fast-acting600Vac20204Low Profile Compact Circuit Protector (CCPLP)UL Class G, CC, and midget fused disconnect switches/bussmannseriesTechnical Data 10372Effective July 2023Catalog numbers:Class G fusesCCPLP-1-20G-S CCPLP-1-20G-P 160020100CCPLP-2-20G-S CCPLP-2-20G-P 260020100CCPLP-3-20G-SCCPLP-3-20G-P360020100Agency information: UL 98 Listed, File E302370, Guide WHTY , CE, RoHS compliant .Class CC fusesCCPLP-2-30CC-S CCPLP-2-30CC-P 260030200—2——CCPLP-3-30CC-S CCPLP-3-30CC-P360030200—347 .5Agency information: UL 98 Listed, File E302370, Guide WHTY , cULus to CSA Standard 22 .2 No . 4-04, File E302370, Guide WHTY7, CE, RoHS compliant .13/32”x1-1/2” UL midget fusesCCPLP-2-30M-S CCPLP-2-30M-P 22403010CCPLP-3-30M-S CCPLP-3-30M-P32403010Agency information: UL 508 Listed, File E320230, Guide NRNT , cULus Listed to CSA 22 .2 No . 14-05, File E320230, Guide NRNT7, CE, RoHS compliant .The CCPLP has the smallest footprint of any UL 98 Listed fuseddisconnect switch along with up to a 200kA SCCR to help improve equipment SCCR .Built-in switch handle / fuse access door interlock prohibits removing the fuse under load .5Technical Data 10372Effective July 2023/bussmannseries Low Profile Compact Circuit Protector (CCPLP)UL Class G, CC, and midget fused disconnect switches Dimensions (reference) – in (mm):All catalog numbersPanel mounting layout (reference) – in (mm):1-, 2- and 3-poles, all catalog numbersLow Profile Compact Circuit Protector (CCPLP)UL Class G, CC, and midget fused disconnect switchesTechnical Data 10372Effective July 2023Eaton, Bussmann and CUBEFuse are valuable trademarks of Eaton in the US and other countries. You are not permitted to use the Eaton trademarks without prior written consent of Eaton.UL is a registered trademark of the Underwriters Laboratories, Inc.Eaton1000 Eaton Boulevard Cleveland, OH 44122United States Eaton .comBussmann Division 114 Old State Road Ellisville, MO 63021United StatesEaton .com/bussmannseries © 2023 EatonAll Rights Reserved Printed in USAPublication No . 10372March 2023For Eaton’s Bussmann series product information,call 1-855-287-7626 or visit:/bussmannseriesFollow us on social media to get thelatest product and support information.The only controlled copy of this data sheet is the electronic read-only version located on the Eaton network drive . All other copies of this document are by definition uncontrolled . This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications . Eaton reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products . Eaton also reserves the right to change or update, without notice, any technical information contained in this bulletin . Once a product has been selected, it should be tested by the user in all possible applications .。

布斯曼系列电源电压熔断器说明书

布斯曼系列电源电压熔断器说明书

Description:Bussmann TM series indicating and non-indicating E-Rated, current-limiting, medium voltage fuses for potential, small power and control transformers.ContentsDescription Page Introduction (2)2.475 kV fuses.........................3-63.6 kV fuses...........................7-9 5.5 kV fuses.........................10-267.2 kV fuses ..........................27-298.3 kV fuses.........................30-39 12 kV fuses ..........................40-42 15.5 kV fuses........................43-52 17.5 kV fuses .........................53-5424 kV fuses ..........................55-5625.5 kV fuses........................57-60 36 kV fuses ..........................61-62 38 kV fuses ..........................63-69 Fuse mountings ......................70-71Features and benefits• Low amp, current-limiting E-Rated PT medium voltage fuses are general purpose fuses defined by their melting time-current characteristic that permit their electrical interchangeability with other fuses of the same E Rating.• E-Rated general purpose fuses must havea current responsive element that will melt in 300 seconds at an RMS current withinthe range of 200% to 240% of the fuse’s nameplate current rating, fuse refill, or link per ANSI C37.46 for fuses rated 100E or less.• PT fuses are physically dimensioned for easy installation in existing hardware.• Space saving size eases design considerations for new installations.• Current-limiting fuses provide positive interruption even on low fault currents.The fuse limits the magnitude of electromechanical stresses in the protected apparatus.• These fuses are in a self-contained, non-venting package for installation indoors or outdoors in an enclosure.• Available in indicating and non-indicating versions.• Open fuse indicator speeds troubleshooting by providing a positive visual indication of fuse operation.T ypical applications• Primary protection of:• Medium voltage potential transformers • Small medium voltage servicetransformers• Small medium voltage controltransformers.PT Medium voltage fuses for potential and small power transformersTechnical Data 6002Effective September 2020PT medium voltage fuses for potential and small power transformers 2/bussmannseries E-Rated PT medium voltage fusesCatalog symbols (by maximum voltage rating):•2.475 kV • 2NCLPT -_•3.6 kV• 3.6ABCNA_• 3.6ABWNA_•3.6CAV_•5.5 kV • JCW-_• 5CLPT -_E • 5NCLPT -_E • 5NCLPT -_E-A • 5.5ABWNA_E • 5.5AMWNA_E • 5.5CAV_E •5.5CAVH_E•7.2 kV • 7.2ABWNA_• 7.2ABCNA_• 7.2AMWNA_E •7.2CAV_•8.3 kV • 8CLPT -_E-A• 8CLPT -_E-B • 8NCLPT -_E • 8NCLPT -_E-A •8NCLPT -_E-B•12kV• 12ABCNA_•12CAV_•15.5 kV • 15CLPT -_E• 15NCLPT -_E-A • 15.5CAV_E •15.5CAVH_E•17.5 kV• 17.5ABGNA_•17.5CAV_•24 kV• 24ABGNA_•24CAV_•25.5 kV • 25CLPT -_E • 36 kV •36ABGNA_• 36CAV_•38 kV• 38CAV_E• 38CAVH_E •38CLPT -_ERatings*:•Volts• 2.4 kV to 38 kV •Amps• 0.25 to 15 A •Interrupting ratings•25 to 80 kA RMS Sym* See catalog number tables for voltages, ampacities and interrupting ratingsby catalog number.Agency information:•Those PT fuses conforming to the requirements for E-Rating meet the performance characteristics of IEEE/ANSI C37.463Technical Data 6002Effective September 2020PT medium voltage fuses for potential and small power transformers/bussmannseries2.475 kV maximum system voltage4.5 (114)0.8 (20) 3.9 (99)1A18370.5—2NCLPT -.5E (63)1—2NCLPT -1E (40)2—2NCLPT -2E (40)5—2NCLPT -5E (25)Dimensions (see catalog number tables for values)Recommended fuseclip and fuse block:Single-pole open fuse block with #10-32 phil-slot screwterminals rated 2500V, 5A maximum and 63kA withstand ratingPTFB-2500-JCDTechnical Data 6002Effective September 2020PT medium voltage fuses for potential and small power transformers4/bussmannseries2.47 kV time-current curves — minimum melting for 2NCLPT-_ECurve TC56357202December 20082NCLPT-_E5Technical Data 6002Effective September 2020PT medium voltage fuses for potential and small power transformers/bussmannseries2.47 kV time-current curves — total clearing for 2NCLPT-_ECurve TC59883702October 20102NCLPT-_ETechnical Data 6002Effective September 2020PT medium voltage fuses for potential and small power transformers6/bussmannseries2.47 kV peak let-through curves for 2NCLPT-_ECurve TC63933702December 20082NCLPT-_E7Technical Data 6002Effective September 2020PT medium voltage fuses for potential and small power transformers/bussmannseries3.6 kV maximum system voltage3.15 5.6 (142) 1 (25)4.4 (112)— 3.6ABWNA3.15 (50)A33547053.157.7 (195) 1 (25) 6.5 (165)— 3.6ABCNA3.15 (50)6.35.6 (142) 1 (25) 4.4 (112)— 3.6ABWNA6.3 (50)6.37.7 (195)1 (25)6.5 (165)— 3.6ABCNA6.3 (50)10— 3.6ABCNA10 (50)Dimensions (see catalog number tables for values)Recommended fuseclips:Open fuseclip for 1.56 (39.7mm) / 1.6 (40.6mm) dia. fuses1A0835Technical Data 6002Effective September 2020PT medium voltage fuses for potential and small power transformers8/bussmannseries3.6 kV Time-current curves — minimum melting for 3.6CAV_, 3.6ABC_ and 3.6ABW_3.6ABC_, 3.6ABW_, 3.6CAV_6.3A (ABC/ABW)10A (ABC/ABW)3.15A (ABC/ABW)2A (CAV)9Technical Data 6002Effective September 2020PT medium voltage fuses for potential and small power transformers/bussmannseries3.6 kV Peak let-through curves for 3.6ABC_ and 3.6ABW_Technical Data 6002Effective September 2020PT medium voltage fuses for potential and small power transformers10/bussmannseries5.5 kV maximum system voltage0.5 5.6 (142) 1 (25) 4.4 (112)— 5.5ABWNA0.5E (50)A33547050.57.4 (188) 1.6 (41) 6.2 (157) 5.5CAVH0.5E (50)JCW-1/2E (40)1A08350.59.5 (241) 1.6 (41)8.1 (206)5CLPT -.5 (80)†5NCLPT -.5E-A (63)1 5.6 (142) 1 (25) 4.4 (112)— 5.5ABWNA1E (50)A33547051 5.6 (142)0.8 (20) 4.8 (122)— 5.5AMWNA1E (63)1A183717.4 (188) 1.6 (41) 6.2 (157) 5.5CAVH1E (50)JCW-1E (40)1A083519.5 (241) 1.6 (41)8.1 (206)5CLPT -1 (80)†5NCLPT -1E-A (63)1.59.5 (241) 1.6 (41)8.1 (206)5CLPT -1.5 (80)†—1A08352 5.6 (142) 1 (25) 4.4 (112)— 5.5ABWNA2E (50)A33547052 5.6 (142)0.8 (20) 4.8 (122)— 5.5AMWNA2E (63)1A183727.4 (188) 1.6 (41) 6.2 (157) 5.5CAVH2E (50)JCW-2E (40)1A083529.5 (241) 1.6 (41)8.1 (206)—5NCLPT -2E (63)1A18373 5.6 (142) 1 (25) 4.4 (112)— 5.5ABWNA3E (50)A335470535.6 (142)0.8 (20) 4.8 (122)— 5.5AMWNA3E (63)1A183739.5 (241) 1.6 (41)8.1 (206)5CLPT -3E (80)5NCLPT -3E (63)1A083537.4 (188) 1.6 (41) 6.2 (157)JCW-3E (40)1A08354 5.6 (142)0.8 (20) 4.8 (122)—5.5AMWNA4E (63)1A183759.5 (241) 1.6 (41)8.1 (206)5CLPT -5E (80)5NCLPT -5E-A (63)1A08355 5.6 (142) 1 (25) 4.4 (112)— 5.5ABWNA5E (50)A33547055 5.6 (142)0.8 (20) 4.8 (122)— 5.5AMWNA5E (63)1A183757.3 (185) 1.6 (41) 5.9 (150)—JCW-5E (40)1A0835109.5 (241) 1.6 (41)8.1 (206)5CLPT -10E (80)5NCLPT -10E-A (63)1A0835157.4 (188)1.6 (41)6.2 (157)—5.5CAV15E (50)† Due to manufacturing variances, this fuse does not comply with ANSI C37.46 for “E” rating. See time-current curves for performance characteristics.CLPT Type mountings and hardware 5.5 kV maximum (4.8kV nominal)*0.5–10Disconnect †605CLPT -PDM-A5CLPT -GDM-ACLPT -DLCLPT -DF* Refers to 5CLPT and 5NCLPT fuses only.** See page 70 for dimensions and diagrams of typical mounting.*** End fittings supplied only when required.† Disconnect mountings provide a means for fuse extraction only. Do not use a disconnect mounting for load switching or fuse removal while energized.Dimensions (see catalog number tables for values)Recommended fuseclips:Open fuseclip for 1.0 (25.4 mm) dia. fuses A3354705 Open fuseclip for 1.56 (39.7 mm) / 1.6 (40.6 mm) dia. fuses1A08355.5 kV time-current curves — minimum melting for 5NCLPT-_-A5NCLPT-_E5.5 kV time-current curves — total clearing for 5NCLPT-_-A5NCLPT-_E5.5 kV peak let-through curves for 5NCLPT-_-A5NCLPT-_E 0.5E-A1E-A & 2E 5E-A3E10E5.5 kV Time-current curves — total clearing for 5CLPT_5CLPT-_Curve TC56353306 August 20115.5 kV peak let-through curves for 5CLPT_5CLPT-_Curve TC63934001March 20135.5 kV time-current curves — minimum melting for 5.5CAV_ and 5.5CAVH_5.5CAV_, 5.5CAVH_5.5 kV time-current curves — total clearing for 5.5CAV_5.5CAV_5.5 kV peak let-through curves for 5.5CAVH_5.5CAVH_P e a k c u t -o f f c u r r e n t i n a m p sRMS Symmetrical prospective current in amps100100010,000100,0000.010.11105.5 kV time-current curves — minimum melting for 5.5ABW_ and 5.5AMW_5.5ABW_, 5.5AMW_5.5 kV time-current curves — total clearing for 5.5ABW_ and 5.5AMW_5.5ABW_, 5.5AMW_5.5 kV peak let-through curves for 5.5ABW_ and 5.5AMW_7.2 kV maximum system voltage1A18371 5.6 (142)0.8 (20) 4.8 (122)—7.2AMWNA1.0E (50)2 5.6 (142)0.8 (20) 4.8 (122)—7.2AMWNA2.0E (50)28.7 (221) 1.6 (41)7.5 (190)—7.2CAV2 (40)1A08353 5.6 (142)0.8 (20) 4.8 (122)—7.2AMWNA3.0E (50)1A18373.15 5.6 (142) 1 (25.4) 4.4 (112)—7.2ABWNA3.15 (45)A33547053.157.7 (195) 1 (25.4) 6.5 (165)—7.2ABCNA3.15 (45)4 5.6 (142)0.8 (20) 4.8 (122)—7.2AMWNA4.0E (50)1A183748.7 (221) 1.6 (41)7.5 (190)—7.2CAV4 (40)1A08355 5.6 (142)0.8 (20) 4.8 (122)—7.2AMWNA5E (50)1A183768.7 (221) 1.6 (41)7.5 (190)—7.2CAV6 (40)1A08356.3 5.6 (142) 1 (25.4) 4.4 (112)—7.2ABWNA6.3 (45)A33547056.37.7 (195) 1 (25.4) 6.5 (165)—7.2ABCNA6.3 (45)108.7 (221)1.6 (41)7.5 (190)—7.2CAV10 (40)1A0835Dimensions (see catalog number tables for values)Recommended fuseclipsOpen fuseclip for 1.0 (25.4 mm) dia. fusesA3354705Open fuseclip for 1.56 (39.7 mm) / 1.6 (40.6 mm) dia. fuses1A08357.2 kV time-current curves — minimum melting for 7.2ABW_ and 7.2CAV_7.2ABW_, 7.2CAV_7.2 kV peak let-through curves for 7.2ABW_8.3 kV maximum system voltage1 5 (127) 1.1 (28) 4 (102)—8NCLPT-1E (50)A335470519.5 (241) 1.6 (41)8.1 (206)—8NCLPT-1E-A (50)1A083528 (203)0.8 (20)7.2 (183)—8NCLPT-2E (25)1A183729.5 (241) 1.6 (41)8.1 (206)—8NCLPT-2E-A (50)1A0835 312.9 (328) 1.6 (41)11.5 (292)8CLPT-3E (50)8NCLPT-3E-B (50)48 (203)0.8 (20)7.2 (183)—8NCLPT-4E (25)1A18375 5 (127) 1.1 (28) 4 (102)—8NCLPT-5E (50)A3354705512.9 (328) 1.6 (41)11.5 (292)8CLPT-5E (50)8NCLPT-5E-B (50)1A08358 5 (127) 1.1 (28) 4 (102)—8NCLPT-8E (50)1012.9 (328) 1.6 (41)11.5 (292)8CLPT-10E (50)8NCLPT-10E-B (50)† Does not comply with ANSI C37.46 for “E” rating.CLPT type mountings and hardware 8.3 kV maximum (7.2 kV nominal)*0.5–2Disconnect†758CLPT-PDM-A8CLPT-GDM-A CLPT-DL CLPT-DF3–10Non-disconnect758CLPT-PNM-B8CLPT-GNM-B CLPT-NL—Disconnect†758CLPT-PDM-B8CLPT-GDM-B CLPT-DL CLPT-DF* Refers to 8CLPT and 8NCLPT-A or -B fuses only.** See page 70 for dimensions and diagrams of typical mounting.*** End fittings supplied only when required.† Disconnect mountings provide a means for fuse extraction only. Do not use a disconnect mounting for load switching or fuse removal while energized. Dimensions (see catalog number tables for values)Recommended fuseclips:Open fuseclip for 1.0 (25.4 mm) dia. fuses A3354705Open fuseclip for 1.56 (39.7 mm) / 1.6 (40.6 mm) dia. fuses1A08358.3 kV time-current curves — minimum melting for 8NCLPT_8NCLPT-_Curve 59887102July 2002Reference # 628852, 598871Curve TC56357206 December 20088.3 kV time-current curves — total clearing for 8NCLPT_8NCLPT-_Curve 59887104July 2002Reference # 598871Curve TC59883706 December 20088.3 kV peak let-through curves for 8NCLPT_8NCLPT-_Curve 63933703July 2001Reference # 639337Curve TC63933704December 20081E5E2E4E8E8.3 kV time-current curves — minimum melting for 8CLPT_8CLPT-_Curve TC56353206 December 20130.5 A fuse melt time in the dotted line region may not be assured due to manufacturing variations. The dotted lines show nominal operation. Some individual fuses may not open until current at 10-second mark is applied.8.3 kV time-current curves — total clearing for 8CLPT_8CLPT-_Curve TC56353306March 20138.3 kV peak let-through curves for 8CLPT_8CLPT-_Curve TC63934001March 20138.3 kV time-current curves — minimum melting for 8NCLPT-_E-A/B8NCLPT-_E-A/B Curve TC70548303December 20088.3 kV time-current curves — total clearing for 8NCLPT-_E--A/B8NCLPT-_E-A/B Curve TC70548403December 20088.3 kV peak let-through curves for 8NCLPT-_E-A/B8NCLPT-_E-A/B Curve TC63934002December 200812 kV maximum system voltage3.157.7 (195) 1 (25) 6.5 (165)—12ABCNA3.15 (45)A3354705Recommended fuseclips:Open fuseclip for 1.56 (39.7 mm) / 1.6 (40.6 mm) dia. fuses1A083512 kV time-current curves — minimum melting for 12ABC_ and 12CAV_12ABC_, 12CAV_12 kV peak let-through curves for 12ABC_15.5 kV maximum system voltage1A0835112.9 (328) 1.6 (41)11.5 (292)15.5CAVH1E (80)15NCLPT -1E-A (50)212.9 (328) 1.6 (41)11.5 (292)15.5CAVH2E (80)15NCLPT -2E (50)312.9 (328) 1.6 (41)11.5 (292)—15.5CAV3E (80)317.6 (447) 1.6 (41)16.1 (409)—15NCLPT -3E (50)317.6 (447) 1.6 (41)16.1 (409)15CLPT -3E (50)—512.9 (328) 1.6 (41)11.5 (292)—15.5CAV5E (80)517.6 (447) 1.6 (41)16.1 (409)15CLPT -5E (50)15NCLPT -5E (50)712.9 (328) 1.6 (41)11.5 (292)—15.5CAV7E (80)1017.6 (447) 1.6 (41)16.1 (409)15CLPT -10E (50)15NCLPT -10E (50)CLPT Type mountings and hardware 15.5 kV maximum (14.4 kV nominal)0.5–2disconnect 9515CLPT -PNM-A 15CLPT -GNM-A CLPT -NL —Disconnect †9515CLPT -PDM-A 15CLPT -GDM-A CLPT -DL CLPT -DF 3–10Non-disconnect 9515CLPT -PNM-B 15CLPT -GNM-B CLPT -NL CLPT -DF Disconnect †9515CLPT -PDM-B15CLPT -GDM-BCLPT -DL—*See page 70 for dimensions and diagrams of typical mounting.** End fittings supplied only when required.†Disconnect mountings provide a means for fuse extraction only. Do not use a disconnect mounting for load switching or fuse removal while energized.Dimensions (see catalog number tables for values)Recommended fuseclips:15.5 kV time-current curves — minimum melting for 15CLPT_15CLPT-_Curve TC56353206August 201115.5 kV time-current curves — total clearing for 15CLPT_15CLPT-_E15.5 kV peak let-through curves for 15CLPT_15CLPT-_Curve TC63934001March 201315.5 kV time-current curves — minimum melting for 15NCLPT_15NCLPT-_Curve TC70548303December 200815.5 kV Time-current curves — total clearing for 15NCLPT_15NCLPT-_Curve TC70548403December 200815.5 kV Peak let-through curves for 15NCLPT_15NCLPT-_Curve TC63934002December 200815.5 kV time-current curves — minimum melting for 15.5CAV_ and 15.5CAVH_15.5CAV_, 15.5CAVH_15.5 kV time-current curves — total clearing for 15.5CAVH_15.5 kV peak let-through curves for 15.5CAVH_15.5CAVH_RMS SYMMETRICAL PROSPECTIVE CURRENT IN KILOAMPS17.5 kV maximum system voltage8.7 (221) 1.6 (41)7.5 (190)1A08354—17.5CAV4 (40)6—17.5CAV6 (40)10—17.5CAV10 (40)Dimensions (see catalog number tables for values)Recommended fuseclips:17.5 kV time-current curves — minimum melting for 17.5CAV_7.5CAV_。

伊顿Bussmann系列EV级车用熔断器-EVK系列(1000Vdc,15-600A)说明书

伊顿Bussmann系列EV级车用熔断器-EVK系列(1000Vdc,15-600A)说明书

EVK Series/系列 (1000 Vdc, 15-600A) Electric Vehicle Fuses 新能源车用熔断器EVK series/系列 (1000 Vdc, 15-600A)2Electric Vehicle Fuses —EVK series (1000 Vdc, 15-600A)新能源车用熔断器 — EVK 系列 (1000 Vdc, 15-600A)Eaton’s Bussmann series Electric Vehicle (EV) full range fuses for the protection of high power and auxiliary electrical systems up to 1000 Vdc in ratings from 15 to 600 amps.伊顿Bussmann 系列EV 级车用熔断器可提供主回路及辅助支路系统的全范围保护,电压达到1000V 直流,电流可以从15A 到600A.Specifications /参数:• Volts / 电压: 1000 Vdc • Amps / 电流: 15-600 A• Interrupting rating / 分断能力: Max / 最大25kA• Time constant / 时间常数: 2±0.5ms• Ambient temperature / 环境温度: -40 ~ 125ºCEVK series/系列 (1000 Vdc, 15-600A)Features /性能:• Excellent design and application experiences with EV for decades, to serve the customers globally在EV 行业内,优秀的产品设计能力和长期的应用经验,服务于世界范围内众多用户• Comply with various international and field EV application standards worldwide符合世界范围及行业内多项EV 熔断器产品标准• Higher voltage rating provides overall system with moreefficient and economical solution while meeting the needs of higher voltage battery packs在满足高压直流电池系统应用的同时,提供给系统更有效且经济的产品方案• Higher interrupting rating projects high capacity batterypacks needed for vehicle long mileage and fast acceleration requirements具有更高的分断能力,适合大容量电池系统的应用,满足车辆长续航和急加速的使用要求• To help project the life of the fuse in the application, unique driving profiles and conditions can be simulated to verify proper fuse size and performance under a wide range of driving behaviors提升了熔断器在使用过程中的寿命,在各种驾驶工况条件下,根据工况条件进行模拟和计算得出合理的参数规格• Operation as low as 135% for 15A to 200A and 200% for 225A to 600A overload provides back up protection to the battery management system能够对电池系统提供135%(15A 到200A )或200%(225A 到600A )的低电流过载保护• More wider protection range with lower MBC and higher IR, much faster opening with low temperature rise under high fault current conditions helps assure reliable protection of circuits and components更低的最小熔断电流值MBC 和更高的最大分断电流值IR ,使得产品具有更广的电流保护范围;更快的熔断速度和较低的产品温升,使得产品在线路发生故障时能提供可靠的保护Catalog symbol / 型号:EVK10-(amp)-T bolt-on /螺栓固定EVK14-(amp)-T bolt-on /螺栓固定EVK22-(amp)-T bolt-on /螺栓固定EVK25-(amp)bolt-on /螺栓固定EVK30-(amp)bolt-on /螺栓固定EVK40-(amp)bolt-on /螺栓固定EVK50-(amp)bolt-on /螺栓固定EVK60-(amp)bolt-on /螺栓固定Basic information /基本信息:P/N / 型号Current / 电流 (A)Packing quantity/包装数量(per container/每包装)Screw / 螺栓Recommended tightening torque /推荐扭矩 (N.m)EVK10-XXX-T 15202530270M5 4.5±1EVK14-XXX-T 35405075M5 4.5±1EVK22-XXX-T 607080100M69±1EVK25-XXX 708090100195M812±1EVK30-XXX 12515017520075M812±1EVK40-XXX 22525027530085M1020±1EVK50-XXX 35040028M1020±1EVK60-XXX45050055060018M1020±1Electric Vehicle Fuses — EVK series (1000 Vdc, 15-600A)新能源车用熔断器 — EVK 系列 (1000 Vdc, 15-600A)3Agency information /相关标准信息:• Designed to / 符合标准: UL248-20 / ISO8820-8 / JASO D622• Manufactured under ITAF16949/VDA6.3 quality system for compliance with automotive requirements在 ITAF16949/VDA6.3 质量系统下制造,符合汽车标准要求• RoHS compliant 符合RoHS 要求• REACH declaration available upon request 根据需要可提供REACH 声明Packaging and installation suggestion / 包装和安装建议:Installation method diagram 安装方式图See below table and right diagram / 见下表及右图The installation surface should be flat and clean without oil stain, etc安装表面应平整、洁净、无油污等EVK series/系列 (1000 Vdc, 15-600A)Dimensions /尺寸: mmSize 系列Current Rating 额定电流(A)A B C D E F G H J EVK1435 ~ 505163.57714.3 5.58120.815.1EVK2260 ~ 8058759022.26.5916123.2EVK14 / EVK22Electric Vehicle Fuses — EVK series (1000 Vdc, 15-600A)新能源车用熔断器 — EVK 系列 (1000 Vdc, 15-600A)4EVK10EVK series/系列 (1000 Vdc, 15-600A)Size 系列Current Rating 额定电流(A)A B C D E F G H EVK2570 ~ 10072.29311025.491119 2.2EVK30125 ~ 20072.29311031911253EVK40225 ~ 30072.210012238.1111328 3.5EVK50350 ~ 40072.210012250.81113285EVK60450 ~ 60072.210012263.51113406EVK25 / EVK30 / EVK40 / EVK50 / EVK60Electric Vehicle Fuses — EVK series (1000 Vdc, 15-600A)新能源车用熔断器 — EVK 系列 (1000 Vdc, 15-600A)5EVK series/系列 (1000 Vdc, 15-600A)0.00010.0010.010.111010010001000010100100010000Prospective Current in Ampere r.m.s.V i r t u a l p r e a r c i n g T i m e (s )T -C curve / 曲线Electric vehicle auxiliary fuses /新能源车用辅助支路熔断器 — EVK10-XXX-T (1000 Vdc, 15-30A)Voltage rating电压 (V)Current rating 额定电流 In(A)Pre-arcing I 2t 弧前 I 2t 值(A 2s)Total I 2t 总I 2t 值(A 2s)Power dissipationat 1.0 I n1.0 I n (W)时功率损耗Power dissipationat 0.5 I n0.5 I n (W)时功率损耗1000Vdc15120700 2.80.6202271,200 3.70.7254802,20040.8306773,4004.91Electric Vehicle Fuses — EVK series (1000 Vdc, 15-600A)新能源车用熔断器 — EVK 系列 (1000 Vdc, 15-600A)6EVK series/系列 (1000 Vdc, 15-600A)T -C curve /曲线Electric vehicle auxiliary fuses /新能源车用辅助支路熔断器 — EVK14-XXX-T (1000 Vdc, 35-50A)Voltage rating电压 (V)Current rating 额定电流 In(A)Pre-arcing I 2t 弧前 I 2t 值(A 2s)Total I 2t 总I 2t 值(A 2s)Power dissipationat 1.0 I n1.0 I n (W)时功率损耗Power dissipationat 0.5 I n0.5 I n (W)时功率损耗1000Vdc354152,1007.5 1.9406203,0008.22501,2305,5009.22.30.00010.0010.010.111010010001000010100100010000Prospective Current in Ampere r.m.s.V i r t u a l p r e a r c i n g T i m e (s )Electric Vehicle Fuses — EVK series (1000 Vdc, 15-600A)新能源车用熔断器 — EVK 系列 (1000 Vdc, 15-600A)7EVK series/系列 (1000 Vdc, 15-600A)Voltage rating电压 (V)Current rating 额定电流 In(A)Pre-arcing I 2t 弧前 I 2t 值(A 2s)Total I 2t 总I 2t 值(A 2s)Power dissipationat 1.0 I n1.0 I n (W)时功率损耗Power dissipationat 0.5 I n0.5 I n (W)时功率损耗1000Vdc603,0009,60012.2 2.4704,68815,00013.4 2.7806,05019,40015.93.2T -C curve /曲线Electric vehicle power fuses /新能源车用主回路熔断器 —EVK22-XXX-T (1000 Vdc, 60-80A)0.00010.0010.010.111010010001000010100100010000Prospective Current in Ampere r.m.s.V i r t u a l p r e a r c i n g T i m e (s )Electric Vehicle Fuses — EVK series (1000 Vdc, 15-600A)新能源车用熔断器 — EVK 系列 (1000 Vdc, 15-600A)8EVK series/系列 (1000 Vdc, 15-600A)T -C curve /曲线Electric vehicle power fuses /新能源车用主回路熔断器 —EVK25-XXX (1000 Vdc, 70-100A)Voltage rating电压 (V)Current rating 额定电流 In(A)Pre-arcing I 2t 弧前 I 2t 值(A 2s)Total I 2t 总I 2t 值(A 2s)Power dissipationat 1.0 I n1.0 I n (W)时功率损耗Power dissipationat 0.5 I n0.5 I n (W)时功率损耗1000Vdc709083,40021.3 4.3801,3674,90024 4.8901,8616,30026.7 5.31002,4308,30029.65.90.00010.0010.010.111010010001000010100100010000Prospective Current in Ampere r.m.s.V i r t u a l p r e a r c i n g T i m e (s )Electric Vehicle Fuses — EVK series (1000 Vdc, 15-600A)新能源车用熔断器 — EVK 系列 (1000 Vdc, 15-600A)9EVK series/系列 (1000 Vdc, 15-600A)T -C curve /曲线Electric vehicle power fuses /新能源车用主回路熔断器 —EVK30-XXX (1000 Vdc, 125-200A)Voltage rating电压 (V)Current rating 额定电流 In(A)Pre-arcing I 2t 弧前 I 2t 值(A 2s)Total I 2t 总I 2t 值(A 2s)Power dissipationat 1.0 I n1.0 I n (W)时功率损耗Power dissipationat 0.5 I n0.5 I n (W)时功率损耗1000Vdc1251,6596,00033.68.4150 2.4789,00040.310.11754,42714,00042.410.62006,27221,00046.911.70.00010.0010.010.1110100100010000100100010000100000Prospective Current in Ampere r.m.s.V i r t u a l p r e a r c i n g T i m e (s )Electric Vehicle Fuses — EVK series (1000 Vdc, 15-600A)新能源车用熔断器 — EVK 系列 (1000 Vdc, 15-600A)10EVK series/系列 (1000 Vdc, 15-600A)T -C curve /曲线Electric vehicle power fuses /新能源车用主回路熔断器 — EVK40-XXX (1000 Vdc, 225-300A)Voltage rating电压 (V)Current rating 额定电流 In(A)Pre-arcing I 2t 弧前 I 2t 值(A 2s)Total I 2t 总I 2t 值(A 2s)Power dissipationat 1.0 I n1.0 I n (W)时功率损耗Power dissipationat 0.5 I n0.5 I n (W)时功率损耗1000Vdc2257,16224,00068.713.72509,03229,00078.715.727511,79635,00083.316.730015,26443,00087.117.40.00010.0010.010.1110100100010000100100010000100000Prospective Current in Ampere r.m.s.V i r t u a l p r e a r c i n g T i m e (s )Electric Vehicle Fuses — EVK series (1000 Vdc, 15-600A)新能源车用熔断器 — EVK 系列 (1000 Vdc, 15-600A)11EVK series/系列 (1000Vdc, 15-600A)Voltage rating电压 (V)Current rating 额定电流 In(A)Pre-arcing I 2t 弧前 I 2t 值(A 2s)Total I 2t 总I 2t 值(A 2s)Power dissipationat 1.0 I n1.0 I n (W)时功率损耗Power dissipationat 0.5 I n0.5 I n (W)时功率损耗1000Vdc35019,11769,00089.317.940028,64797,00096.219.2T -C curve /曲线Electric vehicle power fuses /新能源车用主回路熔断器 — EVK50-XXX (1000 Vdc, 350-400A)0.00010.0010.010.1110100100010000100100010000100000V i r t u a l p r e a r c i n g T i m e (s )-Prospective Current in Ampere r.m.s.Electric Vehicle Fuses — EVK series (1000 Vdc, 15-600A)新能源车用熔断器 — EVK 系列 (1000 Vdc, 15-600A)12EVK series/系列 (1000 Vdc, 15-600A)T -C curve /曲线Electric vehicle power fuses /新能源车用主回路熔断器 —EVK60-XXX (1000 Vdc, 450-600A)Voltage rating电压 (V)Current rating 额定电流 In(A)Pre-arcing I 2t 弧前 I 2t 值(A 2s)Total I 2t 总I 2t 值(A 2s)Power dissipationat 1.0 I n1.0 I n (W)时功率损耗Power dissipationat 0.5 I n0.5 I n (W)时功率损耗1000Vdc45032,604104,000113.128.350040,011120,000129.632.455053,268149,000139.634.960067,948177,000154.838.70.00010.0010.010.1110100100010000100100010000100000V i r t u a l p r e -a r c i n g T i m e (s )Prospective Current in Ampere r.m.s.Electric Vehicle Fuses — EVK series (1000 Vdc, 15-600A)新能源车用熔断器 — EVK 系列 (1000 Vdc, 15-600A)13EVK series/系列 (1000 Vdc, 15-600A)Electric vehicle power fuses /新能源车用主回路熔断器 — EVK series (1000 Vdc, 15-600A)Power loss curve /功率损耗曲线T emperature derating curve /温度降容曲线00.10.20.30.40.50.60.70.80.91010203040506070809100P O W E R L O S S C O R R E C T I O N F A C T O R %O FR ATED CURRENTPower loss curveElectric Vehicle Fuses — EVK series (1000 Vdc, 15-600A)新能源车用熔断器 — EVK 系列 (1000 Vdc, 15-600A)14Note:Electric Vehicle Fuses — EVK series (1000 Vdc, 15-600A)新能源车用熔断器— EVK 系列 (1000 Vdc, 15-600A)15EVK series/系列 (1000 Vdc, 15-600A)Eaton’s mission is to improve the quality of life and the environment through the use of power management technologies and services. We provide sustainable solutions that help our customers effectively manage electrical, hydraulic, and mechanical power – more safely, more efficiently, and more reliably. Eaton’s 2020 revenues were $17.9 billion, and we sell products to customers in more than 175 countries. We have approximately 94,000 employees.Eaton began operation in China more than 20 years ago. Since entering the Chinese market in 1993, Eaton’s presence has grown significantly in the country. In 2004, Eaton moved its Asia Pacific headquarters from Hong Kong to Shanghai.In the Greater China region, Eaton has nearly 9,800 employees,29 manufacturing bases and 5 R&D centers. T oday, we make most products for all of Eaton’s distinct business here.For more information about the company, visit For more information about Eaton China, visit Eaton China official social media account: Eaton_China伊顿公司致力于通过运用动力管理技术和服务来改善人类生活品质并提升环境质量。

美国BUSSMANN NON及NOS系列熔断器规格资料,选型手册

美国BUSSMANN NON及NOS系列熔断器规格资料,选型手册

Carton Quantity and Weight—NOS ONE-TIME (600Vac)Catalog Carton Weight**Number Qty.Lbs.Kg.NOS 1–3010 1.450.657NOS 35–6010 2.6 1.179NOS 70–1005 2.80 1.270NOS 110–2001 1.240.562NOS 225–4001 3.03 1.374NOS 450–60014.632.100**Weight per carton.Form No. NON/ NOSPage 1 of 2Catalog Symbol: NON (250V); NOS (600V)Number Qty.Lbs.Kg.NON ⁄Ω•–30100.380.172NON 35–6010 1.000.453NON 65–10050.790.358NON 110–20010.790.358NON 225–4001 1.650.748NON 450–60012.761.251NON -(1/8-60) is rated at 125Vdc with 50,000 AIC Rating.NON -(65-100) is rated at 125Vdc with 10,000 AIC Rating. **Weight per carton.† For CSA Certified 15-60A Ratings, see PON Data Sheet: 4126Recommended fuseblocks for Class H & K5, 250V & 600V fuses See Data Sheets: 1112 (250V) and1113 (600V)Form No. NON/NOSThe only controlled copy of this Data Sheet is the electronic read-only version located on the Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information con-tained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications.Time-Current Characteristic Curves–Average MeltNON ONE-TIME (250Vac)NOS ONE-TIME (600Vac)。

欧氏·安顿 Bussmann 红色标签 BS 保护罐式熔断器技术数据说明书

欧氏·安顿 Bussmann 红色标签 BS 保护罐式熔断器技术数据说明书

10078Product descriptionEaton’s Bussmann ® series Red Spot centre tagged BS fuse links (in sizes B1 to B4 and C1 to C3 and D1) are specifically designed for the protection of general industrial applications, e.g. power distribution, cable protection, motor protection.Features• Good peak and let-through current limitation •1:1.6 Selective coordinate ratio between ‘downstream’ and ‘upstream’ fuse •gM type offer enhanced motor starting capability•Power loss values well within the limits of IEC 60269-2Red Spot centre bolted tags fuse linksBUSSMANNSERIES2Technical Data 10078Effective October 2017Red Spot centre bolted tags fuse linksEATON Catalogue symbol:• TB(amp)• TBC(amp)• TC(amp)• TF(amp)• TKF(amp)• TKM(amp • TMF(amp)• TM(amp)• TMT(amp)• TTM(amp)• TLM(amp)• TT(amp)• TLU(amp)•TXU(amp)Standard/Agency information:• BS88-2•IEC 60269-2Breaking range and utilisation category:• gG •gMT echnical data:•Breaking capacity: AC: ASTA 20 certified to 80 kA, generally at 660 Volts a.c. to BS88-2 1988 (IEC 60269-2)•Minimum interrupting rating: 1.6 x I nPackaging:• TB and TBC: 20• TC and TF: 10• TKF: 5•TKM, TMF , TM, TMT , TTM, TLM, TT , TLU and TXU: 13Technical Data 10078Effective October 2017Red Spot centre bolted tags fuse linksEATON TB460 V d.c.TB4480 kA gG 750TB6680 kA gG 22150TB101080 kA gG 1701000TB161680 kA gG 1501100TB202080 kA gG 3001670TB252580 kA gG 5003400TB323280 kA gG 10805900TB404080 kA gG 192083809720BC at 550 V a.c.N/ATB505080 kA gG 341013,260TB636380 kA gG 650025,000Dimensions - mmQNNAJP EJ ILO Ġ1E I A E J O A K J @O ĠOTime current curve4Technical Data 10078Effective October 2017Red Spot centre bolted tags fuse linksEATON Cataloguenumbers Rated voltage Rated current (Amps)Breaking capacity Operating classI 2t (A 2s)Fixing centre (mm)Pack quantity Alternative fuse links Compatiblefuse holders Pre-arcing Total at rated voltage TBC2660 V a.c./460 V d.c.280 kA gG 21511120AD at 550 V a.c.RS200TBC4480 kA gG 750TBC6680 kA gG 22150TBC101080 kA gG 1701000TBC161680 kA gG 1501100TBC202080 kA gG 3001670TBC252580 kA gG 5003400TBC323280 kA gG 10805900TBC404080 kA gG 1920838011120BD at 550 V a.c.RS200TBC505080 kA gG 341013,260TBC636380 kA gG 650025,000TBCDimensions - mmQNNAJP EJ ILO Ġ1E I A E J O A K J @O ĠOTime current curve5Technical Data 10078Effective October 2017Red Spot centre bolted tags fuse linksEATON TCCatalogue numbers Rated voltage Ratedcurrent (Amps)BS reference Breaking capacity Operating class I 2t (A 2s) x 103Fixingcentre (mm)Pack quantity Alternative fuse links Compatiblefuse holders Pre-arcing Total at ratedvoltage TC80660-690 V a.c./350 V d.c.80B180 kA gG 146611110L09-660CD at 550 V a.c.RS200TC10010080 kA gG 17100TC100M125100M12580 kA gM 25140TC100M160100M16080 kA gM 62270TC100M200100M20080 kA gM 105430Dimensions - mmTC80 and TC100TC100M125 to TC100M2006Technical Data 10078Effective October 2017Red Spot centre bolted tags fuse linksEATON TFCatalogue numbers Rated voltage Ratedcurrent (Amps)BS reference Breaking capacity Operating class I 2t (A 2s) x 103Fixingcentre (mm)Pack quantity Alternative fuse links Compatible fuse holders Pre-arcing Total at ratedvoltage TF125660-690 V a.c./350 V d.c.125B280 kA gG 2514011110M09-660DD at 415V a.c.RS200TF16016080 kA gG 62270TF20020080 kA gG 105430TF200M250660-690 V a.c./460 V d.c 200M25080 kA gM 200870TF200M315550 V a.c.200M31580 kAgM 3001050Dimensions - mmTF125 to TF200TCQNNAJP EJ ILO ĠTime current curve7Technical Data 10078Effective October 2017Red Spot centre bolted tags fuse linksEATON TFDimensions - mmTF200M250 andTF200M315Time current curveQNNAJP EJ ILO Ġ8Technical Data 10078Effective October 2017Red Spot centre bolted tags fuse linksEATON TKFCatalogue numbers Rated voltageRatedcurrent (Amps)BSreference Breaking capacity Operating class I 2t (A 2s) x 103Fixingcentre (mm)Pack quantity Alternative fuse links Compatible fuse holders Pre-arcing Total at ratedvoltage TKF250660-690 V a.c./460 V d.c250B380 kA gG 2008701115N09-660ED at 415 V a.c.N/ATKF31531580 kA gG 3001350TKF315M355315M35580 kA gM 5002250TKF250Dimensions - mmTKF315 and TKF315M3559Technical Data 10078Effective October 2017Red Spot centre bolted tags fuse linksEATON TKFTime current curveTKMCatalogue numbers Rated voltageRated current (Amps)Breaking capacity Operating class I 2t (A 2s) x 103Fixingcentre (mm)Pack quantity Alternative fuse links Compatible fuse holders Pre-arcing Total at ratedvoltage TKM250660-690 V a.c./460 V d.c25080 kA gG 2008701331N11-660EFS at 415 V a.c.RS400TKM31531580 kA gG 3001350TKM315M355315M35580 kA gM 5002250Dimensions - mm/QNNAJP EJ ILO Ġ10Technical Data 10078Effective October 2017Red Spot centre bolted tags fuse linksEATON TKMTime current curveQNNAJP EJ ILO ĠTMFCatalogue numbers Rated voltageRatedcurrent (Amps)BSreference Breaking capacity Operating class I 2t (A 2s) x 103Fixingcentre (mm)Pack quantity Alternative fuse links Compatiblefuse holders Pre-arcing Total at ratedvoltage TMF355660-690 V a.c./460 V d.c.355B480 kA gG 50022501111P09-660ED at 415 V a.c.N/ATMF40040080 kA gG 6403000TMF400M450400M45080 kA gM 8003800Dimensions - mm11Technical Data 10078Effective October 2017Red Spot centre bolted tags fuse linksEATON TMFTime current curveQNNAJP EJ ILO ĠTMCatalogue numbers Rated voltageRatedcurrent (Amps)BSreference Breaking capacity Operating class I 2t (A 2s) x 103Fixingcentre (mm)Pack quantity Alternative fuse links Compatiblefuse holders Pre-arcing Total at ratedvoltage TM355660-690 V a.c./460 V d.c.355C180 kA gG 5002250133/1841P11/660EF at 415 V a.c.RS400TM40040080 kA gG 6403000TM400M450400M45080 kA gM 8003800Dimensions - mm12Technical Data 10078Effective October 2017Red Spot centre bolted tags fuse linksEATON TMTCatalogue numbers Rated voltage Rated current (Amps)Breaking capacity Operating class I 2t (A 2s) x 103Fixingcentre (mm)Pack quantity Alternative fuse links Compatible fuse holders Pre-arcing Total at ratedvoltage TMT355660 V a.c.35580 kA gG 50022501651P12-660N/ATMT40040080 kA gG 6403000Dimensions - mmTMTime current curveQNNAJP EJ ILO Ġ13Technical Data 10078Effective October 2017Red Spot centre bolted tags fuse linksEATON TTMCatalogue numbers Rated voltageRatedcurrent (Amps)BSreference Breaking capacity Operating class I 2t (A 2s) x 103Fixingcentre (mm)Pack quantity Alternative fuse links Compatible fuse holders Pre-arcing Total at ratedvoltage TTM450660-690 V a.c./450 V d.c.450C280 kA gG 8003800133/1841R11-660FF at 415 V a.c.N/ATTM50050080 kA gG 10504500TTM56056080 kA gG 14005400TTM63063080 kA gG 20007500TTM630M670630M67080 kAgM 24009000Dimensions - mmTMTTime current curveQNNAJP EJ ILO14Technical Data 10078Effective October 2017Red Spot centre bolted tags fuse linksEATON TTMTime current curveQNNAJP EJ ILOQNNAJP EJ ILO ĠTTM450TTM500 to TTM630M67015Technical Data 10078Effective October 2017Red Spot centre bolted tags fuse linksEATON TLMCatalogue numbers Rated voltageRated current (Amps)BSreference Breaking capacity Operating class I 2t (A 2s) x 103Fixingcentre (mm)Pack quantity Alternative fuse links Compatiblefuse holders Pre-arcing Total at ratedvoltage TLM670660-690 V a.c./350 V d.c.670C380 kA gG 24009000133/1841GF at 550 V a.c.N/ATLM71071080 kA gG 28009700TLM75075080 kA gG 370012000TLM80080080 kA gG 440015000Dimensions - mmTime current curveQNNAJP EJ ILO Ġ16Technical Data 10078Effective October 2017Red Spot centre bolted tags fuse linksEATON TTCatalogue numbers Rated voltage Rated current (Amps)Breaking capacity Operating class I 2t (A 2s) x 103Fixingcentre (mm)Pack quantity Alternative fuse links Compatible fuse holdersPre-arcing Total at ratedvoltage TT500660 V a.c./450 V d.c.50080 kA gG 105045001651R12-660FG at 550 V a.c.TT56056080 kA gG 14005400TT63063080 kA gG 20007500Dimensions - mmTime current curveQNNAJP EJ ILO Ġ17Technical Data 10078Effective October 2017Red Spot centre bolted tags fuse linksEATON TLUCatalogue numbers Rated voltage Rated current (Amps)BSreference Breaking capacity Operating class I 2t (A 2s) x 103Fixingcentre (mm)Pack quantity Alternative fuse links Compatiblefuse holders Pre-arcing Total at ratedvoltage TLU560660 V a.c./350 V d.c.560D180 kA gG 140054001491GH at 550 V a.c.N/ATLU63063080 kA gG 20007500TLU75075080 kA gG 370012,000TLU80080080 kA gG 440015,000Dimensions - mmTime current curveQNNAJP EJ ILO Ġ18EATON TXUCatalogue numbers Rated voltageRated current (Amps)BSreference Breaking capacity Operating class I 2t (A 2s) x 103Fixingcentre (mm)Pack quantity Alternative fuse links Compatible fuse holders Pre-arcing Total at ratedvoltage TXU1000660-690 V a.c./350 V d.c.1000D180 kA gG 5300175001491GH at 550 V a.c.N/ATXU1250125080 kA gG 1000029000Dimensions - mmTime current curve1000100000.01110100100000P r e -a r c i n g T i m e (s )1000A1250A0.1100100010000Prospective current (A)EatonEMEA HeadquartersRoute de la Longeraie 71110 Morges, Switzerland Eaton Electrical Products Limited Melton RoadBurton-on-the-Wolds Leicestershire, LE12 5THUnited Kingdom© 2017 EatonAll Rights Reserved PDF OnlyPublication No. 10078 October 2017Eaton is a registered trademark.All other trademarks are propertyof their respective owners.Changes to the products, to the information contained in this document, and to prices are reserved; so are errors and omissions. Only order confirmations and technical documentation by Eaton is binding. Photos and pictures also do not warrant a specific layout or functionality. Their use in whatever form is subject to prior approval by Eaton. The same applies to Trademarks (especially Eaton, Moeller, and Cutler-Hammer). The Terms and Conditions of Eaton apply, as referenced on Eaton Internet pages and Eaton order confirmations.。

艾伦Bussmann系列类型D和D0熔断器链接说明书

艾伦Bussmann系列类型D和D0熔断器链接说明书

4124Product descriptionEaton’s Bussmann ® series Type D and D0 fuse links are specifically designed for the protection of general industrial applications such as power distribution and cable protection.Both types D and D0 are available in threeoperating characteristics: Time-delay, Fast-acting and Ultra-rapid versions that fit into screw cap fuse link carriers for mounting in 1- or 3-pole DIN-Rail or screw fixing.Features and benefi ts:•Characteristics to suit the protection needs of inductive and resistive loads•Fast trouble shooting with easily visible fuse operated pin indicator • Historically reliable range•Wide range of fuse bases and accessories available for many applications•Compliant to IEC 60269 and DIN 49515D and D0 fuse links and basesBUSSMANNSERIESTechnical Data 4124Effective October 2017 D and D0 fuse links and basesCatalogue symbol - T ype D fuse linksFuse LinkSizeTime-Delay Fast-acting Ultra-rapidDI(amp)D16(amp)D16Q(amp)D16RDII(amp)D27(amp)D27Q(amp)D27RDIII(amp)D33(amp)D33Q(amp)D33RDIV(amp)D125(amp)D125Q(amp)D125RDV(amp)D200(amp)D200Q(amp)D200RFuse size• DI• DII• DIII• DIV• DVT o be used with fuse base• E16 (DI)• E27 (DII)• E33 (DIII)• R1 ¼ ” (DIV)• R2 (DV)T echnical data• Volts: 500 V a.c.• Amps: 2 to 200 A• Breaking capacity: 50 kAClass of operation• Time-delay• Fast-acting• Ultra-rapidStandards/Approvals• IEC 60269 and DIN 49515Fuse bases and accessories (ordered separately)• CD27 and CD33 Screw cap fuse link carriers• GD27 and GD33 Screw cap gauge pieces• SFD (1-pole) and TFD (3-pole) Fuse base screw fixing• SFRD (1-pole) and TFRD (3-pole) Fuse base DIN-Rail mount Weight• D16: 12 - 16 grams• D27: 27 - 30 grams• D33: 48 - 52 grams• D125: 105 - 109 grams• D200: 215 grams T able 1. T echnical dataCurrent(Amps)I2t(Amp2 seconds)Nominal wattsloss233 1.5452 1.66100 1.810160 1.416460 2.1201100 2.22520003354700 4.150780056312300 6.98019000N/A 10029000N/A125N/A N/A160N/A N/A200N/A N/ATechnical Data 4124Effective October 2017 D and D0 fuse links and basesT able 2. T ype D Catalogue numbers time delay and fast actingFuse link Operatingcharacteristics GaugeringcolourFuse linksizeTo fit fusebaseCurrent(Amps)Voltage(V a.c.)BdimensionsPackquantity2D16Time-delay Pink DI E162500610 4D16Time-delay Brown DI E164500610 6D16Time-delay Green DI E166500610 10D16Time-delay Red DI E1610500810 16D16Time-delay Grey DI E16165001010 20D16Time-delay Blue DI E16205001210 25D16Time-delay Yellow DI E16255001410 2D27Time-delay Pink DII E272500625 4D27Time-delay Brown DII E274500625 6D27Time-delay Green DII E276500625 10D27Time-delay Red DII E2710500825 16D27Time-delay Grey DII E27165001025 20D27Time-delay Blue DII E27205001225 25D27Time-delay Yellow DII E27255001425 32D33Time-delay Black DIII E33325001625 35D33Time-delay Black DIII E33355001625 40D33Time-delay Black DIII E33405001625 50D33Time-delay White DIII E33505001825 63D33Time-delay Copper DIII E33635002025 80D125Time-delay Silver DIV R1 ¼ ”8050053 100D125Time-delay Red DIV R1 ¼ ”10050073 125D200Time-delay Yellow DV R2125500510 160D200Time-delay Copper DV R2160500710 200D200Time-delay Blue DV R2200500910 2D16Q Fast acting Pink DI E162500610 4D16Q Fast acting Brown DI E164500610 6D16Q Fast acting Green DI E166500610 10D16Q Fast acting Red DI E1610500810 16D16Q Fast acting Grey DI E16165001010 20D16Q Fast acting Blue DI E16205001210 25D16Q Fast acting Yellow DI E16255001410 2D27Q Fast acting Pink DII E272500625 4D27Q Fast acting Brown DII E274500625 6D27Q Fast acting Green DII E276500625 10D27Q Fast acting Red DII E2710500825 16D27Q Fast acting Grey DII E27165001025 20D27Q Fast acting Blue DII E27205001225 25D27Q Fast acting Yellow DII E27255001425 35D33Q Fast acting Black DIII E33355001625 50D33Q Fast acting White DIII E33505001825 63D33Q Fast acting Copper DIII E33635002025 80D125Q Fast acting Silver DIV R1 ¼ ”80500510 100D125Q Fast acting Red DIV R1 ¼ ”100500710 125D200Q Fast acting Yellow DV R2125500510 160D200Q Fast acting Copper DV R2160500710 200D200Q Fast acting Blue DV R2200500910T able 3. T ype D Catalogue numbers ultra rapidFuse linkOperatingcharacteristicsGauge ring colourFuse link sizeTo fit fuse baseCurrent (Amps)Voltage (V a.c.)BdimensionsPack quantity2D16R Ultra rapid Pink DI E1625006204D16R Ultra rapid Brown DI E1645006206D16R Ultra rapid Green DI E166********D16R Ultra rapid Red DI E161050082016D16R Ultra rapid Grey DI E1616500102020D16R Ultra rapid Blue DI E1620500122025D16R Ultra rapid Yellow DI E162550014202D27R Ultra rapid Pink DII E2725006254D27R Ultra rapid Brown DII E2745006256D27R Ultra rapid Green DII E27650062510D27R Ultra rapid Red DII E271050082516D27R Ultra rapid Grey DII E2716500102520D27R Ultra rapid Blue DII E2720500122525D27R Ultra rapid Yellow DII E2725500142530D27R Ultra rapid Black DII E2730500142535D33R Ultra rapid Black DIII E3335500162550D33R Ultra rapid White DIII E3350500182563D33R Ultra rapid Copper DIII E3363500202580D125R Ultra rapid Silver DIV R1 ¼ ”8050053100D125R Ultra rapid Red DIV R1 ¼ ”10050073125D200R Ultra rapid Yellow DV R2125500510160D200R Ultra rapid Copper DV R2160500710200D200R Ultra rapid Blue DV R2200500910DI DIIDIII DIV Dimensions - mmDVTime-current curve - T ype D Fuse links444106-2264-11024610 0262462102610 1466 22410 324610 44621011021034A2A63A50A 35A 25A 20A 16A 6A10A 100A80A 232A 40A13A Cut-off characteristics - T ype D Fuse links2101024610246102461024610241046104262T i m e i n s e c o n d s (S )Current in Amps (A)Prospective current (A)M a x i m u m v a l u e o f c u r r e n t (A )Technical Data 4124Effective October 2017D and D0 fuse links and basesAccessories for type D Fuse linksT able 4. Screw cap fuse links carriers Screws into fuse base.T able 5. Screw cap gauge piecesFuse rating rejection insert to prevent incorrect fuse rating from being installed.Catalogue numberFuse link sizeTo fit fuse base type Current (Amps)Pack qtyCD27DII E272550CD33DIII E336330Catalogue numberColourCurrent (Amps)Fuse link sizeTo fit fuse base type Packqty2GD27Pink 2DIIE27254GD27Brown 4DII E27256GD27Green 6DII E272510GD27Red 10DII E272516GD27Grey 16DII E272520GD27Blue 20DII E272525GD27Yellow 25DII E272535GD33Black 35DIII E332550GD33White 50DIII E332563GD33Copper 63DIII E3325Fuse carrier/capRated current (Amps) A BC D 2GD273/16” 6.517244GD273/16” 6.517246GD273/16” 6.5172410GD273/16”8.5172416GD273/16”10.5172420GD273/16”12.5172425GD273/16”14.5172435GD333/16”16.5173050GD333/16”18.5173063GD333/16”20.51730Gauge pieceDimensions - mm2GD274GD276GD2710GD2716GD2720GD2725GD2735GD3350GD3363GD33Technical Data 4124Effective October 2017D and D0 fuse links and basesT able 6. Fuse base screw fixingTFD27Catalogue numberNumber of poles Fuse link sizeTo fit fuse base type Current (Amps)Pack qtySFRD271-pole DII E272515TFRD273-pole DII E27254SFRD331-pole DIII E336315TFRD333-pole DIII E33636T able 7. Fuse base DIN-Rail mountDIN-Rail mount receptacle to hold screw cap fuse link carrier and fuse link.SFRD33TFRD27TFDDimensions - mmTFRDTechnical Data 4124Effective October 2017 D and D0 fuse links and bases+Fitting exampleCD27Screw cap fuse link carrier10D27Fuse link10GD27Screw capgauge pieceTFD27Fuse basepanel mount++Technical Data 4124Effective October 2017 D and D0 fuse links and basesCatalogue symbol - T ype D0 fuse linksFuse link size Time-delay Ultra-rapidD01(amp)NZ01(amp)NZ01RD02(amp)NZ02(amp)NZ02RD03(amp)NZ03N/AFuse size• D01• D02• D03T o be used with fuse base• E14 (D01)• E18 (D02)• M30 x 2 (D03)T echnical data• Volts: 400 V a.c.• Amps: 2 to 100 A• Breaking capacity: 50 kAOperating class• Time-delay• Ultra-rapidStandards/Approvals• IEC 60269 and DIN 49515Packaging• 10 per cartonWeight• NZ01: 6 grams• NZ02: 11 - 15 grams• NZ03: 35 grams T able 8. T echnical dataCurrent (Amps)I2t (Amp2 seconds)Nominal watts loss 2330.8452 1.16100 1.210160 1.116460 1.7201100 1.7252000 2.3354700 2.8507800 3.863123005Fuse bases and accessories (ordered separately)• CN01, CN02 and CN03 screw cap fuse link carriers• GN01 and GN02 screw cap gauge pieces• FN_C, FRNC-SA, FRN-SB, FRN-SD, FRN-SE single pole fuse base screw fixing• TFN_C, TFRNC-SA, TFRN-SB, TFRN-SD, TFRN-SE triple pole fuse base screw fixing• FRN_C, FRNC-A, FRN-B, FRN-D, FRN-E single pole fuse base DIN-Rail mounting• TFRN_C, TFRNC-A, TFRN-B, TFRN-D, TFRN-E triple pole fuse base DIN-Rail mounting• PPD01 and PPD02 Plastic base• D0-GPK gauge piece key• D0-SFH special holderDimensions - mmSee catalogue numbers table for dimensionA.Use with fusebase E14Use with fusebase E18Use with fusebase M30 x 2Technical Data 4124Effective October 2017 D and D0 fuse links and basesT able 9. T ype D0 fuse link catalogue numbersCatalogue numbers Operatingcharacteristics Gauge ring colourFuse linksizeTo fit fusebaseCurrent(Amps)Voltage(V a.c.)Adimensions Pack qty2NZ01Time delay Pink D01E1424007.310 4NZ01Time delay Brown D01E1444007.310 6NZ01Time delay Green D01E1464007.310 10NZ01Time delay Red D01E14104008.510 16NZ01Time delay Grey D01E14164009.710 20NZ02Time delay Blue D02E182040010.910 25NZ02Time delay Yellow D02E182540012.110 35NZ02Time delay Black D02E183540013.310 50NZ02Time delay White D02E185040014.510 63NZ02Time delay Copper D02E186340015.910 80NZ03Time delay Silver D03M30 x 28040021.410 100NZ03Time delay Red D03M30 x 210040021.410 2NZ01R Ultra rapid Pink D01E1424007.310 4NZ01R Ultra rapid Brown D01E1444007.310 6NZ01R Ultra rapid Green D01E1464007.310 10NZ01R Ultra rapid Red D01E14104008.510 16NZ01R Ultra rapid Grey D01E14164009.710 20NZ02R Ultra rapid Blue D02E182040010.910 25NZ02R Ultra rapid Yellow D02E182540012.110 35NZ02R Ultra rapid Black D02E183540013.310 50NZ02R Ultra rapid White D02E185040014.510 63NZ02R Ultra rapid Copper D02E186340015.910Time-current curve - T ype D0 fuse links - Time-delay11EATON 12EATON Accessories for type D0 Fuse linksT able 10. Fuse cap fuse link carriers Screws into fuse base.Catalogue numberFuse link size Pack qtyCN01D0120CN02D0220CN03D0320T able 11. Screw cap gauge piecesFuse rating rejection insert to prevent incorrect fuse rating from being installed.DimensionsCatalogue numberColourCurrent (Amps)Fuse link sizeTo fit fuse base type PackqtyAB2GN01Pink 2D01E14507.9124GN01Brown 4D01E14507.9126GN01Green 6D01E14507.91210GN01Red 10D01E14509.1122GN02*Pink 2D02E18507.916.64GN02*Brown 4D02E18507.916.66GN02*Green 6D02E18507.916.610GN02*Red 10D02E18509.116.616GN02*Grey 16D02E185010.316.620GN02Blue 20D02E185011.516.625GN02Yellow 25D02E185012.716.635GN02Black 35D02E185013.916.650GN02White 50D02E185015.116.62GN01CN01Fuse carrier/capDimensions - mmDimensions - mm* For using fuse links D01 and fuse bases D024GN016GN0110GN0116GN0220GN0225GN0235GN0250GN0213EATON ConnectionsCatalogue number Current (Amps)ScrewWith protection cover Withoutprotection cover DIN-Rail mountingScrewfixingOutlet SupplyCross-section of connecting lead (mm 2)Dim (A)mm Pack qtyFRN01C 16E14x xM4M4 1.5-45315FN01C 16E14x xM4M4 1.5-45315FRN02C 63E18x x2 x M5 2 x M5 2.5-255715FN02C 63E18x x2 x M5 2 x M5 2.5-255715FRN02C-A 63E18x x2 x M5M6 2.5-25575FRN02C-SA 63E18xx2 x M5M6 2.5-255715FRN01-B 16E14x xM4M4 1.5-45315FRN01-SB 16E14x xM4M4 1.5-45315FRN02-D 63E18x x2 x M5 2 x M5 2.5-25575FRN02-SD 63E18x x2 x M5 2 x M5 2.5-255715FRN02-E 63E18x x2 x M5M6 2.5-255715FRN02-SE 63E18xx 2 x M5M6 2.5-255715T able 12. Single pole fuse basePanel mount receptacle to hold screw cap fuse link carrier and fuse link.Dimensions - mmConnectionsCatalogue number Current (Amps)Screw With protection cover Withoutprotection cover DIN-Rail mountingScrewfixingOutlet SupplyCross-section ofconnecting lead (mm 2)Dim (A)(mm)Pack qtyTFRN01C 16E14x xM4M4 1.5-4535TFN01C 16E14x xM4M4 1.5-4535TFRN02C 63E18x x2 x M5 2 x M5 2.5-25575TFN02C 63E18x x2 x M5 2 x M5 2.5-25575TFRN02C-A 63E18x x2 x M5M6 2.5-25575TFRN02C-SA 63E18xx2 x M5M6 2.5-25575TFRN01-B 16E14x xM4M4 1.5-4535TFRN01-SB 16E14x xM4M4 1.5-4535TFRN02-D 63E18x x2 x M5 2 x M5 2.5-25575TFRN02-SD 63E18x x2 x M5 2 x M5 2.5-25575TFRN02-E 63E18x x2 x M5M6 2.5-25575TFRN02-SE 63E18xx 2 x M5M6 2.5-25575T able 13. Three pole fuse basePanel mount receptacle to hold screw cap fuse link carrier and fuse link.Dimensions - mmFN01C FRN01CTFRN02CEatonEMEA Headquarters Route de la Longeraie 71110 Morges, Switzerland Eaton Electrical Products Limited Melton RoadBurton-on-the-WoldsLeicestershire, LE12 5TH United Kingdom © 2017 EatonAll Rights Reserved PDF OnlyPublication No. 4124October 2017Eaton is a registered trademark.All other trademarks are property of their respective owners.Accessories for type D0 Fuse linksTypeCatalogue number To fit fuse link Number of polesRated current(A)Dim B (mm)Pack qtyPPD01-1PDD01-1D0111626.81PPD01-3PDD01-3D0131680.43PPD02-1PDD02-1D0216326.815PPD02-3PDD02-3D0236380.45T able 14. Plastic base PDD01 and PDD02++Fitting exampleCN01Fuse cap fuse link carrier16NZ01Fuse link16GN02Screw cap gauge ringFRN02C DIN-Rail fuse mount++Catalogue numberPack qtyMOQ D0-GPK 2020T able 15.Gauge piece keyCatalogue numberPack qtyD0-SFH25T able 16. Special holderDimensions - mmChanges to the products, to the information contained in this document, and to prices are reserved; so are errors and omissions. Only order confirmations and technical documentation by Eaton is binding. Photos and pictures also do not warrant a specific layout or functionality. Their use in whatever form is subject to prior approval by Eaton. The same applies to Trademarks (especially Eaton, Moeller, and Cutler-Hammer). The Terms and Conditions of Eaton apply, as referenced on Eaton Internet pages and Eaton order confirmations.。

美国BUSSMANN FNQ-R系列低压熔断器规格书

美国BUSSMANN FNQ-R系列低压熔断器规格书

11-20-02SB02450Form No. FNQ-RPage 1 of 2Data Sheet: 1014Dimensional DataGeneral Information:•The Bussmann CC-TRON ®(FNQ-R) was designed to meet the needs of control circuit transformer protection.•Current-limitation protects down stream components against damaging thermal and magnetic effects of short-circuit currents.•High inrush time-delay.Control circuit transformers can experience inrush currents up to 85 times their full-load current rating. FNQ-R fuses can be sized according to NEC and UL requirements and still allow the high inrush currents, with significantly more time-delay than the UL minimum value of 12 seconds at 200% for Class CC fuses.•Melamine tube. Nickel-plated brass endcaps.Electrical Ratings (Catalog Symbol and Amperes)FNQ-R-⁄Ω¢FNQ-R-1‹Ω¡ºFNQ-R-3¤Ω¡ºFNQ-R-8FNQ-R-‹Ω¡ºFNQ-R-1›Ω¡ºFNQ-R-3⁄Ω™FNQ-R-9FNQ-R-›Ω¡ºFNQ-R-1⁄Ω™FNQ-R-4FNQ-R-10FNQ-R-⁄Ω™FNQ-R-1flΩ¡ºFNQ-R-4⁄Ω™FNQ-R-12FNQ-R-flΩ¡ºFNQ-R-1°Ω¡ºFNQ-R-5FNQ-R-15FNQ-R-‹Ω¢FNQ-R-2FNQ-R-5flΩ¡ºFNQ-R-17⁄Ω™FNQ-R-°Ω¡ºFNQ-R-2⁄Ω¢FNQ-R-6FNQ-R-20FNQ-R-1FNQ-R-2⁄Ω™FNQ-R-6⁄Ω¢FNQ-R-25FNQ-R-1⁄Ω•FNQ-R-2°Ω¡ºFNQ-R-7FNQ-R-30FNQ-R-1⁄Ω¢FNQ-R-3FNQ-R-7⁄Ω™—Catalog Symbol: FNQ-R Time-DelayApplication: Circuit Transformer Protection Ampere Rating: ⁄Ω¢ to 30AVoltage Rating: 600Vac (or less)†Interrupting Rating:200,000A RMS Sym. (UL)Agency Information:UL Listed, Std. 248-4, Class CC, Guide JDDZ, File E4273CSA Certified, Class CC CSA, Class 1422-01, File 53787–HRC-MISC†12-30A is 300Vdc and 10k AIR.Maximum Acceptable Rating of Overcurrent Device*Maximum Rating of Overcurrent Rated PrimaryProtective Device Expressed As A Current Percent of Transformer Primary(Amperes)Current RatingLess than 2A 500**2A to less than 9A 1679A or more125*UL 508A Table 42.1.**300% for other than motor control applications.Form No. FNQ-RPage 2 of 2Data Sheet: 1014The only controlled copy of this Data Sheet is the electronic read-only version located on the Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information con-tained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications.11-20-02SB02450Recommended fuseblocks/fuseholders for Class CC 600V fusesSee Data Sheets listed below • Open fuseblocks - 1105• Finger-safe fuseholders - 1109, 1102, 1103, 1151• Panel-mount fuseholders - 2114, 2113• In-line fuseholders - 2126。

Bussmann 系列类 J 模块熔断器板产品说明说明书

Bussmann 系列类 J 模块熔断器板产品说明说明书

Class J modular ferrule and knifeblade fuse blocksCatalog symbol:• JM60_Description:Bussmann® series Class J modular fuse blocks increase versatility, reduce labor and enhance safety for any panel or electrical system design. Available for the full Class J fuse amp range. These fuse blocks feature a standard fuseclip reinforcing spring for enhanced electrical contact between the blcok and fuse. All blocks are available as single-pole versions that snap together for the required number of poles, or as factory configured 2-, and 3-pole versions to meet stocking requirements.The modular design permits reducing inventory, assembly time and labor with tool-less assembly of multiple poles at point of use.Ferrule fuse blocks up to 60 amps save panel space with the smallest width dimension on the market and feature DIN-Rail and panel mount versatility so that one product can be used for multiple applications with lower inventory cost.Knifeblade fuse blocks from 100 to 600 amps feature phase barriers between poles for additional safety with up to four mounting holes per pole increase installation flexibility. All knifeblade blocks meet UL creep and clearance requirements for Industrial Power Circuits (UL 508 and UL 845). Additionally, the 200 to 600 amp blocks meet the higher UL creep and clearance requirements for Power Distribution Standards (UL 98, UL 67, UL 489, UL 891 and UL 869A)All blocks have optional IP20 finger-safe high clarity, see-through covers for inspecting wire terminations or thermography measurements without removal. All covers enhance safety by featuring probe holes for easier, safer testingand a lockout/tagout capability. These coversalso have optional open fuse indication to speed troubleshooting.Easy circuit identification is available for 30 and60 amp blocks and covers with universal marker labels.Specifications:Ratings• Volts 600 V• Amps up to 600 A• Withstand 200 kA RMS SymAgency information• Blocks:• UL® Listed E14853 — IZLT and IZLT7• CSA® Certified 47235-6225-01• CE• RoHS Compliant• REACH declaration available upon request • Covers:• UL Listed E58836 - JDVS• CSA Certified 47235-6225-01 (30 and 60A)• RoHS Compliant• REACH declaration available upon request2Technical Data 10488Effective January 2023Class J modular ferrule and knifeblade fuse blocks/bussmannseriesPoles• 1-, 2-, 3-pole units factory assembled•Single-pole units snap together to create desired number of polesFlammability ratings• Blocks: UL 94V0, self-extinguishing •Covers: UL 94HB, self-extinguishingOperating and storage temperature range• Blocks -40°C to +120°C•Covers;• Non-Indicating -40°C to +120°C•Indicating -20°C to +90°C** Indication requires minimum 90V and closed circuit to illuminate.Materials• Base: Thermoplastic•Terminals:• Tin-plated copper brass (30 and 60A)•Tin-plated aluminum (box lug)•Covers: ThermoplasticConductors•See catalog numbers for details and torque specifications.Optional see-through covers provide IP20 finger-safe protection and feature a lockout/tagout provision to improve electrical safety. These covers are also available with open fuse indicating version for faster troubleshooting. Order separately, one cover perblock pole.Standard dual lugs on 600A blocks and optional dual lugs on 400A blocks for easier wiring using two, smaller conductors.30 and 60 amp ferrule fuse blocks have DIN-rail and panel mounting capability, the modular designs allows blocks toand snap together for the desired number of poles. They accept optional snap-on covers for IP20 finger-safe protection and feature a lockout/tagout to improve electrical safety.100 to 600 amp knifeblade fuse blocks are panel mount with multiple holes for installation flexibility and the modular design allows blocks to snap together for the desired number of poles. They accept optional snap-on covers for IP20 finger-safe protection and feature a lockout/tagout provision to improve electrical safety.Modular Class J ferrule and knifeblade fuse blocksOn blocks rated from 100 to 600A, the optional covers can be completely removed for servicing or simply hinged open.3Technical Data 10488Effective January 2023Class J modular ferrule and knifeblade fuse blocks /bussmannseries Table 1: 30 and 60 amp block catalog numbersup to 30CVRI-J-60030CVR-J-600302JM60030-2CR JM60030-2CHR JM60030-2SR JM60030-2PR 3JM60030-3CR JM60030-3CHR JM60030-3SRJM60030-3PR35 to 601JM60060-1CR JM60060-1CHR ——CVRI-J-60060CVR-J-600602JM60060-2CR JM60060-2CHR 3JM60060-3CRJM60060-3CHR* Covers sold separately, one cover per pole.** Open fuse indication requires 90 volts minimum and closed circuit to operate.Probe holes for easy testing without removing cover*No fuse derating necessary.on each pole provides installation flexibilityStandard phase barriers for additional safetyFinger grips on cover for easy removalLockout/tagout feature improves safetyVent slots improve cooling*Table 2: 30 and 60 amp block terminals and conductorsBox lug 75°C Cu 2-14, AL 2-84-6 5.1 (45)8 4.5 (40)10-14 4.0 (35)#10-32 Phil-slot screw 75/90°C Cu 10-1810-182.3 (20)Pressure plateRecommended Bussmann series fuses:delay fusesup to 601006Advanced protection Limitron JKS fast-acting fusesup to 601026High speed DF J drive fuseup to 601048Recommended accessories for 30 and 60 amp blocks:DIN-Rail end stops BRKT-NDSCREW2Marker labelsTM26CB4Technical Data 10488Effective January 2023Class J modular ferrule and knifeblade fuse blocks/bussmannseriesDimensions; 30A Class J block - in (mm)JM60030-1CRLOCKOUT - TAGOUT RINGSCVR-J-60030 (COVER NON-INDICATING)CVRI-J-60030 (COVER WITH INDICATION)JM60030-3CRPROVISION FOR MARKING LABELJM60030-2CR5Technical Data 10488Effective January 2023Class J modular ferrule and knifeblade fuse blocks /bussmannseries18.7Dimensions; 60A Class J block - in (mm)JM60060-2CRJM60060-1CRPROVISION FOR PROVISION FOR MARKING LABELPROVISION FOR6Technical Data 10488Effective January 2023Class J modular ferrule and knifeblade fuse blocks/bussmannseriesInstalling blocks on DIN-RailPlace one edge of DIN-Rail in fuse block base, then rotate block down until it clicks into place.Installing /removing coversInstall cover: Position cover over block and push straight down until it snaps/clicks into place.Open cover: Using bothoutside handles,pull straight up.Detail AFor larger conductors, trim center tab at notch as show in detail A.Trim tab7Technical Data 10488Effective January 2023Class J modular ferrule and knifeblade fuse blocks /bussmannseriesTable 6: Class J 100 to 600 amp knifeblade blocks and covers70-1001JM60100-1CR CVR-J-60100-MCVR-J-60100-M1/0-3 AWG; (2) Cu 4-6 AWG Cu 4-6 AWG 5.6 (50)2JM60100-2CR 2 4-6 AWG; (2) Cu 8 AWG Cu 8 AWG 5.1 (45)8 AWG; (2) Cu 10-14 AWG — 4.5 (40)3JM60100-3CR Cu 10-14 AWG; Al 10-12 AWG —4.0 (35)110-2001JM60200-1CR CVR-J-60200-MCVR-J-60200-M250kcmil-1 AWGCu 3/0-1 AWG 42 (375)2JM60200-2CR 2-6 AWG; (2) Cu 2-6 AWG Cu 2-6 AWG31 (275)3JM60200-3CR 225-4001JM60400-1CR CVR-J-60400-MCVR-J-60400-M600kcmil N/A57 (500)2JM60400-2CR 500kcmil-4 AWG 51 (450)3JM60400-3CR (2) Cu 3/0 - 4 AWG 57 (500)(2) Al 3/0 - 4 AWG 34 (300)1JM60400-1MW22250kcmil-1 AWGCu 3/0-1 AWG 42.37 (375)2JM60400-2MW222-6 AWG; (2) Cu 2-6 AWGCu 2-6 AWG 31.07 (275)3JM60400-3MW22450-6001JM60600-1CR CVR-J-60600CVRI-J-606002 (2) 500kcmil-4 AWGN/A51 (450)2JM60600-2CR 3JM60600-3CR* Covers sold separately.** Open fuse indication requires 90 volts minimum and closed circuit to operate.*** Ratings for copper and aluminum conductors except where otherwise noted.Standard dual lugs on 600A blocks and optional dual lugs on 400A blocks for easier wiring using two, smaller conductors.Probe holes for easy testing without removing cover*No fuse derating necessary.Finger-safe wire entry with cutout tabs for larger wires on all versionseach pole provide flexible, secure mountingStandard phase barriers for additional safetyFinger grips on coverfor easy removalOptional open fuse indicationspeeds troubleshootingLockout/tagout feature improves safetyVent slots improve cooling*for easy point-of-use assemblyOptional see-through, snap-on Recommended Bussmann series fusesdelay fuses70 to 6001007Advanced protection Limitron JKS fast-acting fuses70 to 6001026High speed DF J drive fuse70 to 60010488Technical Data 10488Effective January 2023Class J modular ferrule and knifeblade fuse blocks/bussmannseriesDimensions; 100A Class J block - in (mm)138 TYP JM60100-3CRJM60100-1CRJM60100-2CRCVR-J-60100-M(COVER NON-INDICATING)CVRI-J-60100-M(COVER WITH INDICATION)REMOVE FOR WIRE LARGER THAN 6 AWGJM60100-1CR (SHOWN WITH COVER)9Technical Data 10488Effective January 2023Class J modular ferrule and knifeblade fuse blocks /bussmannseries Dimensions; 200A Class J block - in (mm)JM60200-1CRJM60200-2CRJM60200-3CRREMOVE FOR WIRE LARGER THAN 2 AWGJM60200-1CR (SHOWN WITH COVER)10Technical Data 10488Effective January 2023Class J modular ferrule and knifeblade fuse blocks/bussmannseriesDimensions; 400A Class J block - in (mm)441.79TYP TYP 1/2" TYP271.1JM60400-3CRJM60400-1MW22JM60400-2CRJM60400-1CRCVR-J-60400-M(COVER NON-INDICATING)CVRI-J-60400-M(COVER WITH INDICATION)REMOVE FOR WIRE LARGER THAN 250KCMILREMOVE ONL Y FOR DUAL LUGJM60400-1CR (SHOWN WITH COVER)11Technical Data 10488Effective January 2023Class J modular ferrule and knifeblade fuse blocks /bussmannseries Dimensions; 600A Class J block - in (mm)2349.219.8TYP 151JM60600-1CR (SHOWN WITH COVER)CVR-JM60600 (COVER NON-INDICATING)CVRI-JM60600(COVER WITH INDICATION)JM60600-3CRJM60600-1CR JM60600-2CRClass J modular ferrule and knifeblade fuse blocksTechnical Data 10488Effective January 2023Eaton and Bussmann are valuable trademarks of Eaton in the U.S. and other countries. Y ou are not permitted to use the Eaton trademarks without prior written consent of Eaton.Eaton1000 Eaton Boulevard Cleveland, OH Bussmann Division 114 Old State Road Ellisville, MO 63021United States/bussmannseries © 2023 EatonAll Rights Reserved Printed in USAPublication No. 10488January 2023Follow us on social media to get thelatest product and support information.For Eaton’s Bussmann series product information,call 1-855-287-7626 or visit:/bussmannseriesThe only controlled copy of this data sheet is the electronic read-only version located on the Eaton network drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Eaton reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Eaton also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications.。

Bussmann系列紧凑型熔断器基础CCP2B说明书

Bussmann系列紧凑型熔断器基础CCP2B说明书

Compact, finger-safe fused branch disconnect offers superior circuit protection Compact Circuit Protector BaseThe Bussmann series CCPB delivers 200 kA SCCR in a compact, finger-safe design.Eaton’s next generation Bussmann™ seriesCompact Circuit Protector Base (cat. no.CCP2B) is a high 200 kA Short-Circuit CurrentRating (SCCR), bolt-mount, finger-safe fusedUL® 98 Listed disconnect switch available in1-, 2- and 3-poles.The CCPB is a full voltage rated switch up to600 Vac, ideal for panel builders who wantto incorporate a fusible solution that can beinstalled in any electrical system withoutthe issues associated with slash-ratedovercurrent protective devices.Using the Bussmann series Class CFCUBEFuse TM makes compliance with NationalElectrical Code (NEC®) and CanadianElectrical Code (CEC) selective coordinationrequirements easy in an all-fused systemor in systems with tested upstream circuitbreakers.Features• Uses the current-limiting, time-delay orfast-acting Bussmann series UL ClassCF CUBEFuse available in ratings from1 to 100 amps to closely match loadrequirements for superior protection• 200 kA SCCR helps achieve highassembly SCCR• UL 98 Listed as a branch circuitdisconnect• Built-in switch/fuse interlock preventsremoving the fuse while energized• 1/4” lockout/tagout provision forenhanced safety• Open fuse indication lamp speedstroubleshooting• Horsepower rated for motor disconnectapplicationsSERIESCompact Circuit Protector Base About amp rating rejectionAmp rating rejection prevents the CCPB from accepting any CUBEFuse with a greater amp rating than that of the switch. This means that the properly sized conductor cannot inadvertently be protected by a CUBEFuse with a greater amp rating than the wire’s ampacity. For example, the 15 amp CCPB will accept any CUBEFuse from 1 to 15 amps, the 50 amp CCPB will accept any CUBEFuse from 1 to 50 amps and the 100 amp CCPB will accept any CUBEFuse from 1 to 100 amps.About the CUBEFuseThe Bussmann series UL Class CF CUBEFuse features Class J fuse electrical performance in a compact, finger-safe package. Available in ratings from 1 to 100 amps, the current-limiting CUBEFuse helps mitigate arc flash hazard and is available in time-delay and fast-acting versions. The time-delay Low-Peak TM version also has optional open fuse indication on ratings from 6 to 100 amps.The wide selection of amp ratings, along with the time-delay and fast-acting versions, permitsspecifying a CUBEFuse that meets inductive or resistive load needs, and permits sizing of fuses closer to load for enhanced component protection.See data sheet No. 9000 (time-delay) or No. 2147 (fast-acting) for additional information.All 1-, 2- and 3-pole versions of the CCPB feature amp rating rejection to help prevent overfusing.CCP2B at-a-glanceEaton, Bussmann, CUBEFuse and Low-Peak are valuable trademarks of Eaton in the U.S. and other countries. You are not per-mitted to use the Eaton trademarks without prior written consent of Eaton.NEC is a registered trademark of the National Fire Protection Association, Inc.UL is a registered trademark of the Underwriters Laboratories, Inc.Eaton1000 Eaton Boulevard Cleveland, OH 44122United States Bussmann Division 114 Old State Road Ellisville, MO 63021United States/bussmannseries © 2018 EatonAll Rights Reserved Printed in USAPublication No. 10270August 2018For Eaton’s Bussmann series product information,call 1-855-287-7626 or visit:/bussmannseriesFollow us on social media to get thelatest product and support information.See data sheet No.1161 for additional information.Fuse rejection breaks:15, 20, 30, 40, 50, 60, 70, 90 and 100 A Agency information:• UL 98 Listed, Guide WHTY , File E302370• cULus to Canadian Standard 22.2 No. 4, Guide WHTY7, File E302370• CE compliant •RoHS compliantCCP2B-(pole)-20CF CCP2B-(pole)-70CF CCP2B-(pole)-30CF CCP2B-(pole)-90CF CCP2B-(pole)-40CF CCP2B-(pole)-100CFCCP2B-(pole)-50CFSwitch handle Lockout/tagout provisionLocal open fuse indication lightSwitch ON and OFF symbolsCUBEFuse base。

Bussmann熔断器

Bussmann熔断器

额定电压选择需要了解?
– 电路图 – 交流输入电压(有效值) – 直流排电压 – 是否有再生制动模式?
额定电压
熔断器: UN=1250V 1100V G
额定电压
正确
Load
熔断器: UN=690V 900V G
Load
错误
额定电流选择需要了解?
– 负荷电流有效值 – 环境温度 – 连接排的截面积 – 有无风冷及风速 – 频率 – 是否水冷及水温 – 过载情况 – 周期负荷情况
Cooper Bussmann快速熔断器简介
标准产品系列 熔断器结构 快熔额定参数 底座及配件 指示器系统 技术参数 Bussmann快熔与普通工业熔断器相比所具有的优势
快速熔断器系列 (标准) 英标BS88系列
北美系列
圆柱型 (法标)
方体系列 (欧标)
1893
2008
熔断器结构
BS 88
பைடு நூலகம்
美国标准
方体快熔
外形
外形
US/BS 88 French Flush End
DIN 43620 DIN 43653
尺寸
尺寸
美标快熔
快熔的标准额定参数
方体
130VAC – 1000VAC 80VDC – 800VDC
BS 88
1A – 4000A 690VAC – 1250VAC 10A – 9000A
圆柱形
额定电流
额定电流
熔断器: IN=315A 220A G
典型选择
Load
熔断器: IN=315A 315A G
非常少见
Load
电流修正系数
– Kt ,环境温度 :
– Ke,热连接

Eaton Bussmann CUBEFuse系列快速作用熔断器产品说明说明书

Eaton Bussmann CUBEFuse系列快速作用熔断器产品说明说明书

Product description:Eaton’s Bussmann™series fast-acting CUBEFuse™ delivers a faster response to damaging faults to help reduce destructive thermal and magnetic forces. It is ideally suited for UPS and other critical applications.The industry's first finger-safe CUBEFuse is a Class CF fuse that provides the same electrical performance as a Class J fuse, but with a significantly smaller footprint.Features and benefits:•Fast-acting protection specifically for UPS and other critical applications.•Finger-safe fuseminimizes exposure to live parts, reducing the likelihood of accidental contact with energized parts.•Integral use with Compact CircuitProtector (cat. no. CCP2) or CUBEFuse holder to minimize panel space.•Minimizes incidentenergy and reduces arc flash hazards utilizing Class J current-limiting electrical characteristics.•Smallest footprint of any class fuse including Class CC, J, RK and T .Complementary products:Fast-acting protection with up to a 75% smaller footprintBussmann seriesfast-acting CUBEFuse delivers the smallest installed footprint of any Class CC, J, RK or T fuse.TCFH_N30, 60, or 100 A holdersCCP2_CF1-, 2-, and 3-pole UL 98 disconnect switchesCompact Circuit Protector Base 1-, 2-, and 3-pole branch circuit disconnects (cat. no. CCP2B) for use with Quik-Spec TM CoordinationPanelboardSERIESFast-acting CUBEFuse™SpecificationsCatalog symbol:•FCF_RNProduct benefits:• Industry's first finger-safe power fuse system• Smallest footprint of any class fuse including Class CC, J, RK and T • Class CF meets Class J fast-acting electrical performance requirements •Faster response to damaging faults to help reduce destructive thermal and magnetic forces• True fast-acting fuse construction• High interrupting rating to safely interrupt faults up to 300 kA• No venting of arc or molten metal and gases during opening•Low let-through currents under fault conditionsFast-acting fuse:• 4-minute maximum clearing time at 200% rated current for 1 to 30 A fuse•6-minute maximum clearing time at 200% rated current for 35 to 60 A fuse•8-minute maximum clearing time at 200% rated current for 70 to 100 A fuseRatings:• Volts 600 Vac/dc*• Amps 1 to 100 A •Interrupting ratings• 300 kA RMS Sym. (up to 60 A UL ®)• 200 kA RMS Sym. (CSA ® and 70-100 A UL)• 50 kA DC (UL and CSA)* 600 Vdc rating only applicable when used with theCUBEFuse holder (TCFH)Agency information :• UL Listed fuse: Guide JDDZ, File E4273• CSA Certified, Class 1422-02, File 53787• RoHS compliant •CEOther ratings/specifications:•Watts loss at rated current • FCF15RN: 3.48 W • FCF30RN: 5.45 W • FCF60RN: 7.27 W • FCF100RN: 11.50 W•Operating and storage temperature range -40°C to 80°CMaterial specifications:• Case glass filled PES (polyethersulfone) case• Terminals copper alloy• Terminal plating electroless tinEaton, Bussmann, CUBEFuse andQuik-Spec are valuable trademarks of Eaton in the U.S. and other countries. You are not permitted to use the Eaton trademarks without prior written consent of Eaton.CSA is a registered trademark of the Canadian Standards Group.UL is a registered trademark of the Underwriters Laboratories, Inc.Eaton1000 Eaton Boulevard Cleveland, OH 44122United States Bussmann Division 114 Old State Road Ellisville, MO 63021United States/bussmannseries © 2018 EatonAll Rights Reserved Printed in USAPublication No. 3183October 2018For Eaton’s Bussmann series product information,call 1-855-287-7626 or visit:/bussmannseriesThe DIN-Rail mounted 1-, 2-, and 3-pole CCP2_CF comes in 30, 60 and 100 A versions. T heCCP2_CF is a compact, horsepower rated UL 98 disconnect that delivers the smallest footprint of any Class J solution, requiring up to 51% less space. Local, neon open fuse indication is standard (same as the CCP2B in the Quik-Spec Coordination Panelboard). 2- and 3-pole versions are ganged and all versions offer a lockout/tagout provision for added safety.See data sheet no. 10801 for more information.1-, 2-, and 3-pole CCP2B is an amp ratingrejecting branch disconnect for the QSCP that uses the CUBEFuse up to 100 A.See data sheet no. 1160 for more information.All 30, 60 and 100 A CUBEFuse holders can be dovetailed together for the required number of poles with the smallest fuse footprint possible for the amp rating.See CUBEFuse holder data sheet no. 9007 formore information.FCF1RN X X X X X X FCF3RN X X X X X X FCF6RN X X X X X X FCF10RN X X X X X X FCF15RN X X X X X X FCF20RN X X X X X X FCF25RN X X X X X X FCF30RN XX X XX X FCF35RN X X X X FCF40RN X X X X FCF45RN X X X X FCF50RN X X X X FCF60RN XX XX FCF70RN XX FCF80RN X X FCF90RN XX FCF100RNXXSee data sheet no. 2147 (fuses), no. 9007 (holders) and no. 10801 (CCP2_CF) for additionalinformation.Follow us on social media to get thelatest product and support information.。

Bussmann easyID 荧光标标用熔断器与插座说明书

Bussmann easyID 荧光标标用熔断器与插座说明书

Product description:Bussmann™ series easy IDilluminating blade fuses and holders use Light Emitting Diode (LED) technology to indicate that a fuse has opened, making it easy to spot in fuse panels tucked under dark dashboards. Illuminating blade fuses are the ideal choice for fast and easy fuse replacement.Popular fuse types (ATR,ATC, ATM, Maxi™, FMX) are available in common fuse ratings for consumer convenience.ATR fuses are the latestspace-saving fuses for newer vehicles, while ATC fuses are used in both new and older automobiles and light trucks.ATM fuses are used for a wide variety of applications involving late-model OEM vehicles.Maxi fuses are used for protecting circuits in wiring harnesses (usually found under the hood in a fuse panel near the battery) and are increasingly used in domestic cars and some imports.Female Maxi (FMX) fuses are used for late-model vehicles and are available in the most popular amp ratings.Find blown fuses fast with easy ID™Indicating blade fuses and in-line fuse holders SERIESNew in 2019easy ID ATRilluminating fusesFeatures and benefits:•Available in popular sizes and ratings tocover the most common replacement fuse needs.•Illuminating fuse holders use regular ATM and ATC blade fuses.•Universal color coding makes it easier tomatch with a traditional non-illuminating fuse.•Value packs, assortment and service kits provide popular packaging options to maximize retail sales.•Specialty (black)packaging helps fuses stand out in any retail setting as being the superior choice.BP/ATC-AID ATC fuse assortment (1) ATC-10, (1) ATC-15, (1) ATC-20, (1) ATC-25, (1) ATC-30************ATC-ID-SK ATC fuse service kit (6) ATC-5, (6) ATC-10, (6) ATC-15, (6) ATC-20, (6) ATC-25, (6) ATC-30************BP/ATM-AID ATM fuse assortment (1) ATM-5 (1) ATM-10, (1) ATM-15, (1) ATM-20, (1) ATM-25, (1) ATC-30************ATM-ID-SKATM fuse service kit(6) ATM-5, (6) ATM-10, (6) ATM-15, (6) ATM-20, (6) ATM-25, (6) ATM-30************BP/FMX-30ID 30Pink ************1 3.72" x 1.77" x 0.58"5 2.88" x 1.88" x 3.82"12012.00” x 12.00” x 4.13”BP/FMX-40ID 40Green ************1 3.72" x 1.77" x 0.58"5 2.88" x 1.88" x 3.82"12012.00” x 12.00” x 4.13”BP/FMX-50ID 50Red ************1 3.72" x 1.77" x 0.58"5 2.88" x 1.88" x 3.82"12012.00” x 12.00” x 4.13”BP/FMX-60ID60Yellow************13.72" x 1.77" x 0.58"52.88" x 1.88" x3.82"12012.00” x 12.00” x 4.13”Eaton, Bussmann, easy ID and Maxi are valuable trademarks of Eaton in the US and other countries. You are not permitted to use the Eaton trademarks without prior written consent of Eaton.© 2018 EatonAll Rights Reserved Printed in USAPublication No. 5085October 2018Eaton1000 Eaton Boulevard Cleveland, OH 44122United States Bussmann Division 114 Old State Road Ellisville, MO 63021United States/bussmannseries Follow us on social media to get thelatest product and support information.For Eaton’s Bussmann series product information,call 1-855-287-7626 or visit:/BussmannConsumereasyID Illuminating single-amp retail packsATC-FHID 32 V/20 A #16************MAX-FHID32 V/20 A#6************easyID Illuminating holders for blade fusesLED Indicator。

布斯曼(Bussmann)供应商保险丝系列BMSeries型号M的产品数据和技术信息说明书

布斯曼(Bussmann)供应商保险丝系列BMSeries型号M的产品数据和技术信息说明书

Form No. BM SeriesPage 1 of 1BIF Doc #1104The only controlled copy of this BIF document is the electronic read-only version located on the Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information con-tained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications.1-16-02SB02003Dimensional Data All dimensions (±0.015)#10-#18#10-#18#6-#14Catalog Symbol:BM SeriesType M Supplementary Fuseblocks Ampere Rating:⁄Ω¡º to 30 Amperes Voltage Rating:600 Volts ACWithstand Rating:10,000 A RMS Sym. or interrupting r ating of the fuse used, whichever is lower.Agency Information:U.L. Recognized, U.L. 512, Guide IZLT2, File E14853CSA Certified, C22.2 No. 39, Class 6225-01, File 47235For use with any ⁄‹Ω£™∑ ≈ 1⁄Ω™∑ Fuses(Bussmann KTK, FNQ, FNM, BAF, BAN and AGU)U.L. Flammability:94 V0Material:ThermoplasticCatalog Data (600V)Terminal Type Screw with Quick Pressure Plate w/Box Fig.Amps Poles Connect*Quick Connect*LugNo.⁄Ω¡º1BM6031SQ BM6031PQ BM6031B 1to 2BM6032SQ BM6032PQ BM6032B 2303BM6033SQBM6033PQ BM6033B 3O B S O L E T o m m e n d e d r M M m o d u l a a s。

Eaton Bussmann系列的内联和增加熔断器刀刃保持器及端口说明书

Eaton Bussmann系列的内联和增加熔断器刀刃保持器及端口说明书

Inline blade fuse holders provide a wide variety of circuit protection optionsProduct description:Eaton Bussmann ® series inline and add-a-fuse blade fuse holders and taps meet a variety of automotive and marine circuit protection needs.Easily applied foradding circuits to power accessories, inline bladefuse holders are available up to 60 amps.Bussmann series inline blade fuse holders areavailable for the new, micro ATR blade fuses, compact ATM and low-profile ATM fuses, popular ATC fuses and, for high power needs, MAX fuses.Package options include traditional, retail and bulk packs.Inline holders are available for ATR, ATM, ATC and MAX blade fusesFeatures and benefits:•easy ID™ holders indicate a blown fuse. Available for ATM, ATC and MAX fuses.•Now available for ATR micro fuses, conventional holders meet basic needs for circuit protection. Available for ATR, ATM, ATC and MAX fuses.•Add-a-fuse holders plug into fuse blocks to create a new, fused circuit for auxiliary and accessory loads. Available for the new ATR micro fuses, ATM and low-profile ATM and ATC fuses.•Gasket-sealed holders seal out contaminants. They are available for ATM and ATC fuses and are ideal for trailers and marine applications where waterinfiltration is a problem.Inline blade fuse holdersEaton, Bussmann and easy ID are valuable trademarks of Eaton in the US and other countries. You are not permitted to use the Eaton trademarks without prior written consent of Eaton.Eaton1000 Eaton Boulevard Cleveland, OH 44122United States Bussmann Division 114 Old State Road Ellisville, MO 63021United States/bussmannseries © 2016 EatonAll Rights Reserved Printed in USAPublication No. 10484January 2016Follow us on social media to get thelatest product and support information.For Eaton’s Bussmann series product information,call 1-855-287-7626 or visit:/bussmannseriesEaton Bussmann series inline blade fuse holders are available in a variety of styles andratings to meet your customer’s circuit protection needs.Add-a-fuse holders easy ID holders Gasket-sealed holders Conventional holders Now available for ATRmicro-blade fusesFuse taps。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

Circuit Protection Solutions Low Voltage Fuse Links CatalogueTable of ContentsDomestic Applications to BS1361 & BS1312Consumer Unit Fuse Link4Plug T op Fuse Links4Industrial & Motor Applications to BS88Offset Bolted Tags 5 - 7 Centre Bolted T ags8 - 9 Offset Blade Tags10Merchandising Stand11Industrial Applications to BS88 - 500VdcSpecial DC Range Offset/Centre Bolted Tag12Industrial Applications to BS88 - 660/690VOffset Bolted Tags 13 Centre Bolted T ags14 Special Tag Arrangements15Street Lighting Applications to BS88Offset Bolted Tags16Utility Applications to BS88House-Service Cut-Out Fuse Links17 J Type Fuse Links to BS88: Part 5 Cylindrical17 J Type Fuse Links to BS88: Part 5 Slotted/Non Slotted 18Joint NATO Reference SystemCylindrical/Offset Bolted T ag19BS88 FuseholdersCamaster HRC Fuseholder20 Safeloc Fuseholder21Cylindrical Domestic Fuses22Domestic Fuses23Cylindrical Industrial FusesClass gG 24 Class aM25 CHD26 CHM27 CH28NH Fuses - Dual IndicatorClass gG - Low Power Loss29 - 30 Class gG 31 Class aM32 -33 Class gG - aM34NH Fuses - Dimensions35NH Fuseholders for Knife Fuses36 Dimensions for Knife fuse and Fuseholders (NH)37 - 38 NH Fuse Rails and Disconnectors39 - 41DO Fuses42DO Fuseholders43D Fuses44D Fuseholders45Other Low Voltage Fuse Ranges 46Medium Voltage Fuses and Isolators47Ultra Fast Fuses and Holders48 - 49Domestic Applications to BS1361 & BS1312Offset Bolted Tags 240 - 550V ac / 2 - 32ASpecificationsDescription:Fuse Links for general industrial applications with Q1 fusing factor - general purpose (gG) and motor protection (gM) characteristicsApplications:General Industrial & Motors applicationsIndustrial & Motor Applications to BS88Ratings:Agency information:Meets BS88: Part 1 & 2 (1988),IEC 269: Parts 1 (1986) RoHS CompliantFixing Unit Part No Dimensions (mm)A B C D E F G NITD 55.04434.611.213.80.814.0NITD32M35.617.51.218.5Part No Dimensions (mm)A B C D E F G H AAO 857335.513.714 1.28.78.0AAO32M54.52122.3Volts:-415 - 550V ac Amps:- 2 - 32AIR -80kA @ 415/550V acData Sheet:4106Data Sheet:4109Offset Bolted Tags (Cont.../...)240-550V / 32 - 100ASpecificationsDescription:Fuse Links for general industrial applications with Q1 fusing factor - general purpose (gG) and motor protection (gM) characteristicsApplications:General Industrial & Motors applicationsIndustrial & Motor Applications to BS88Ratings:Agency information:Meets BS88: Part 1 & 2 (1988),IEC 269: Parts 1 (1986) and CSA C22.2 No 106-M 1985RoHS CompliantPart No Dimensions (mm)A B C D E F G H J BAO 877354.52122.51.212.78.05.5BAO63MPart No Dimensions (mm)ABC DEFGHJCEO 1109458.521.024.53.214.311.08.7CEO100M125 &16025.826.8CEO100M20047.03129.519.010.09.0Volts:-415 - 550V ac Amps:-32 - 100AIR -80kA @ 415 / 550V acOffset Bolted Tags (Cont.../...)240 - 550V ac / 80 - 200ASpecificationsDescription:Fuse Links for general industrial applications with Q1 fusing factor - general purpose (gG) and motor protection (gM) characteristicsApplications:General Industrial & Motors applicationsIndustrial & Motor Applications to BS88Ratings:Agency information:Meets BS88: Part 1 & 2 (1988),IEC 269: Parts 1 (1986) RoHS CompliantPart No Dimensions (mm)A B C D E F G H J OSD 95.07354.521.022.5 1.212.78.05.5OSD100M26.025.7Part No Dimensions (mm)A B C D E F G H J DEO 1109447.031.029.53.219.010.09.0DEO200MVolts:-415 - 550V ac Amps:-80 - 200AIR -80kA @ 415 / 550V acCentre Bolted Tags415 - 550V ac / 2 - 1250A 250V dcSpecificationsDescription:Fuse Links for general industrial applications with Q1 fusing factor - general purpose (gG) and motor protection (gM) characteristicsApplications:General Industrial & Motors applicationsIndustrial & Motor Applications to BS88Ratings:Agency information:Meets BS88: Part 1 & 2 (1988),IEC 269: Parts 1 (1986) RoHS CompliantPart NoA B AC 113.597.5AD 128.5111BC 113.597.5BC63M BD 128.5111CD126111CD100M125 & CD100M160CD100M200136DD 136111DD200M ED250136111ED315ED315M4009.0ED400M500Volts:-415 - 550V ac / 250V dc Amps:- 2 - 1250AIR -40kA @ 250V dc-80kA @ 415 / 550V acData Sheets:AC:4110 / BC:4113 / AD:4111 / BD:4114 / CD:4116 / DD:4118 / ED:4119Centre Bolted Tags (Cont.../...)415 - 550Vac / 125 - 1250A 250 - 400VdcSpecificationsDescription:Fuse Links for general industrial applications with Q1 fusing factor - general purpose (gG) and motor protection (gM) characteristicsApplications:General Industrial & Motors applicationsIndustrial & Motor Applications to BS88Ratings:Agency information:Meets BS88: Part 1 & 2 (1988),IEC 269: Parts 1 (1986) RoHS CompliantFG / GG / GH550V ac / 450 - 1250A 250V dc (Type GG 710-800A only)400V dc (Type FG)Catalogue NumbersDimensionsDimensionsUnit Interrupting Volts:-415 - 550V ac / 250V dc Amps:- 2 - 1250AIR-40kA @ 250V dc GF, GG except 1000 & 1250A -40kA @ 400V dc FG, FF -80kA @ 415/550V acData Sheets:EFS:4121 / EF:4120 / FF:4102 / GF:4103Data Sheets:FG:4122 / GG:4104 / GH:4108Offset Blade Tags 240 - 550V / 2 - 63ASpecificationsDescription:Fuse Links for generalindustrial applications with Q1 fusing factor -general purpose (gG) and motorprotection (gM) characteristics.Ratings:Applications:General Industrial and Motors applicationsAgency Information:Meets BS88: Part 6, 1988 and IEC 269: Parts 1, 1986RoHS Compliant DimensionsCatalogue NumbersIndustrial & Motor Applications to BS88Volts:-240V ac (SSD)-415V ac (NSD gM) / ESD gG (40 - 63A)-550V ac (NSD gG) / ESD gG (2 - 32A)Amps:- 2 - 63AIR -33kA @ 240V ac -80kA @ 500V acData Sheet SSD:4105Data Sheet NSD:4100Merchandising Stand SpecificationsDescription:Merchandising stand with BS88 fuses packed in packs of 3’s or 10’s Stand dimensions:1.88 Metre tall x 0.91 Metre wide x 0.51 Metre deep* (including hooks)Catalogue NumbersPoint of Sale StandPlease note this stand is for the UK market onlyFor Product Data Sheets, visit Special DC RangeOffset/Centre Bolted Tag 500Vdc / 10 - 63ASpecificationsDescription:Fuse links for industrial DC applications available in offset and centre bolted tags Ratings:Applications:Protection of DC electrical circuits Agency information:ASTA approved to BS88 part 2RoHS Compliant DimensionsCatalogue NumbersVolts:-500V dc Amps:-10 - 63AIR -40kA @ 500V dcData Sheet:E578501712For Product Data Sheets, visit Offset Bolted Tags 660-690V / 2 - 200ASpecificationsDescription:Fuse links for industrial applications at 660/690V that meets dimensional and performancerequirements of BS88 and IEC 269-1-2standardsRatings:Applications:Protection of large industrial installations at 600/690VacAgency information:Meets BS88: Part 1 & 2 and IEC 269: Parts 1 & 2RoHS CompliantCatalogue NumbersVolts:-660 / 690V ac -250V dc (2 - 63A)-400V dc (80 - 200A)Amps:- 2 - 200AIR -80kA @ 660V ac -40kA @ 400V dcData Sheet H07:4150Data Sheet K07:4151Data Sheet L14:4152Data Sheet M14:415313For Product Data Sheets, visit Centre Bolted Tags660 - 690V ac / 2 - 630A 250 - 400V dcSpecificationsDescription:Fuse Links for industrial applications at 660/690V that meets dimensional and performancerequirements of BS88 and IEC 269-1-2standards.Ratings:Applications:Protection of large industrial installations at 660/690VacAgency Information:Meets BS88: Part 1 & 2 and IEC 269: Parts 1 & 2RoHS Compliant DimensionsCatalogue NumbersIndustrial Applications to BS88 - 660/690VDimensions (mm)A B C D E F G 111.092.553.722.02.412.713.0111.593.054.225.0127.011153.722.0 2.414.015.2128.011154.225.0Part NoDimensions (mm)A B C D E F G L09-660136.011165.535.5 3.219.015.18.7M09-660135.011165.037.0 3.219.015.08.7N09-660135.011173.049.0 3.225.412.79.5P09-660135.511175.058.5 4.725.412.79.5N11-660162.013373.049.03.225.415.810.5Volts:-660 / 690V ac-250V dc (2 - 63A) (K08, K09)-400V dc (80 - 630A) (L09, M09, N09,P09, N11, P11, P12, R11, R12)Amps:- 2 - 630AIR-80kA @ 660V ac-40kA @ 250V dc/400V dcData Sheets:K08:415 / L09:4156 / M09:4157 / N09:4158 / P09:4159 / N11:4160 / P11:4161 / R11:4162 / R12:416214Low Voltage Fuse Links Catalogue For Product Data Sheets, visit Special TagArrangements 660 - 690V / 125 - 800ASpecificationsDescription:Fuse Links for industrial applications at 660/690V that meets dimensional and performancerequirements of BS88 and IEC 269-1-2standards.Ratings:Applications:Protection of large industrial installations at 600 / 690VacAgency Information:BS88 part 1 section 2-1 & 2-2RoHS Compliant Dimensions Catalogue NumbersIndustrial Applications to BS88 - 660/690VPart No Dimensions (mm)A B C D E F GH M13120.099.070.038.027.08.026.012.0M23262.0231.0167.038.519.014.0N15120.0100.079.049.041.016.515.0Dimensions (mm)Offset Bolted TagCentre Bolted TagSpecial T ag ArrangementVolts:-660 / 690V ac (except S20 type - 550V ac)-400V dc (except S20 type)Amps:-125 - 800AIR -80kA @ 660V ac-40kA @ 400V (except S20 type)Data Sheets:M13 & M23:4153 / N15:4164 / N34:4165 / P35:4161 / R40:4162 / N20:4166 / P20:4167 / R20:4168 / S20:E578504515For Product Data Sheets, visit Offset Bolted Tags 240 - 550V / 2 - 32ASpecificationsDescription:Fuse Links for general street lightingapplications with Q1 fusing factor - general purpose (gG) Applications:Street lighting applicationsSMD415V ac (gG) / 2 - 32AStreet Lighting Applications to BS88Ratings:Agency information:Meets BS88: Part 1 & 2 (1988),IEC 269: Parts 1 (1986) RoHS CompliantSTD240V ac /2 - 32ACatalogue NumbersDimensionsCatalogue NumbersDimensions Volts:-240 - 415V ac Amps:- 2 - 32AIR -33kA @ 240V ac (STD)-80kA @ 415 / 550V ac (SMD)Data Sheet:412316Also available as Offset Bladed T ags “SSD”, see page 10For Product Data Sheets, visit House Service Cut-Out Fuse Links 415V / 5 - 100ASpecificationsDescription:Cylindrical Fuse Links for electrical utilities to BS Standard Ratings:Applications:Fuses to use in connection with House Service cut-outs.Agency Information:ASTA certified and tested in accordance to BS 1361RoHS Compliant Catalogue NumbersJ Type Fuse Links to BS88:Part 5 Cylindrical Type 415V / 20 - 250ASpecificationsDescription:Cylindrical type fuses designed for use with wedge type fuse carriers on BS applications Ratings:Applications:For use by Electrical Authorities in distribution pillars, open type substation boards,heavy duty cut-outs, and underground connection boxes. Cylindrical type to be used in pole or wall mounted outdoor service fuse units.Agency information:ASTA certifed and tested to BS88: Part 5RoHS Compliant Catalogue Numbers:DimensionsUtility Applications to BS88KR85 TypeLR85 TypeVolts:-415V Amps:- 5 - 100AIR -33kA @ 415VDimensions Volts:-415VAmps:-20 - 250AIR -80kA @ 415VData Sheet KR85:4185Data Sheet LR85:4186Data Sheet:417717For Product Data Sheets, visit J Type Fuse Links to BS88:Part 5Slotted/Non Slotted Types 415V / 20 - 800ASpecificationsDescription:Slotted type fusesdesigned for use with wedge type fuse carriers on BS applications Ratings:Applications:For use by Electrical Authorities indistribution pillars, open type substation boards, heavy duty cut-outs, and underground connection boxes.Agency information:ASTAcertified and tested BS88:Part 5RoHS Compliant Utility Applications to BS88Slotted Type (MJ31-7 up to 200A)DimensionsVolts:-415VAmps:-20 - 630A (Slotted Type)800A (Non Slotted Type)IR -80kA @ 415VCatalogue NumbersData Sheets:MJ30-8:4178A / MJ30-7:4178B / MJ31-7 or 8:4180 / PJ31:4181 / RJ:4182 / SJ:418318For Product Data Sheets, visit Cylindrical/Offset Bolted Tag 440V / 0.25 - 150ASpecificationsDescription:Cylindrical Fuse linksoriginally developped for the Admiralty but are now used in a wide variety of applicationsRatings:Applications:defence, aeronautical, allied industries,electronicsAgency information:Defence standard 59-96(superceding DEF 63). Tested to BS88 at 440V/33kA RoHS Compliant Dimensions Joint NATO Reference SystemCatalogue NumbersCylindricalOffset Bolted TagVolts:-440VAmps:-0.25 - 100A (Cylindrical)-0.5 - 150A (Offset Bolted Tag)IR -33kA @ 440VacData Sheets:size 0:4188/ size 1:4189 / size 2:4190 / size 3:419119For Product Data Sheets, visit CMCAM ASTER HRC Fuseholder690V ac / 20 - 400ASpecificationsDescription:Fully shrouded fuse bases with unique cam action system for BS88Fuse link applications.Ratings:Applications:Lighting and heating equipment,circuit protection, Motor protection, Control equipment circuit protectionAgency Information:CE Compliance to BS88, EN IEC 60269. For UL and CSA approved versions also available,consult Cooper Bussmann ®RoHS CompliantDimensionsCatalogue NumbersBS88 FuseholdersVolts:-660V acAmps:-20, 32 (Compact) 32, 63 and 100A Accesories Numbers* 200A & 400A do not have the CAM actionNotes:1 - Type CM32FC is also available rated at 20A,catalogue number CM20F2 - For colours other than Black (standard) add the appropriate letter code: W = White; G = Green,GY = Grey3 - Care must be taken when fitting solid single or stranded cables of small cross-sectional area to ensure correct clamping. Small Multi-stranded cables must be terminated with bootlace ferrules to ensure correct clamping. Bootlace ferrules should not be used on standard power cables or high current applications. If in doubt please consult Cooper Bussmann ®4 - A +5% tolerance should be allowed on dimensions when cutting metal work to fit CAMaster fuse holders20For Product Data Sheets, visit NNS,ENSSafeloc Fuseholder 660V ac / 32 - 63ASpecificationsDescription:Fuseholder to be used with BS88 Fuse links for bolted panel mounting or DIN rail.Ratings:Applications:Lighting and heating equipment,circuit protection, Motor protection, Control equipment circuit protectionAgency Information:CE Compliance to BS88, EN IEC 60269RoHS Compliant DimensionsCatalogue NumbersBS88 FuseholdersVolts:-550V ac, 415V ac (63A)Amps:-32, 63ANotes:1 - For colours other than Black (standard), add the appro-priate letter code: W = White, G = Green, GY = Grey, at the end of the catalogue reference.2 - Security seal (ref. 32551) available for 32A Safeloc3 - Care must be taken when fitting solid single or stranded cables of small cross-sectional area to ensure correctclamping. Small Multi-stranded cables must be terminated with bootlace ferrules to ensure correct clamping. Bootlace ferrules should not be used on standard power cables or high current applications. If in doubt please consult Cooper Bussmann ®4 - A +5% tolerance should be allowed on dimensions when cutting metal work to fit Safeloc fuse holders21For Product Data Sheets, visit Class gG (gF)250 - 400V / 0.5 - 32A Sizes:6x23,8x23,10x258x31,10x31,8x3610x38SpecificationsDescription:Cylindrical fuses for domestic protection.Available in types with and without striker indicator.Ratings:Applications:Protection of power lines, heatingcircuits, lighting circuits. electrical domestic appliances and domestic electricity metersAgency Information:NF C 62203, EN IEC 60269-3,NF marking (see references in bold in catalogue numbers chart)RoHS Compliant DimensionsCylindrical Domestic FusesVolts:-250V ac (6x23, 8x23, 10x25)400V ac (8x31, 10x31, 8x36, 10x38)Amps:-0.5 - 32AIR -6kA (6x23, 8x23, 10x25)-20kA (8x31, 10x31, 8x36, 10x36)Catalogue Numbers22*UP = Unit PackingNFC 60203For Product Data Sheets, visit AD440V ac / 15 - 90A Sizes:10x38,14x51,22x58 (cylindrical fuses)00 (Knife fuses)SpecificationsDescription:fuse cartridge type AD for fitting to circuit breakers on low-voltage branch circuits.Ratings:Applications:Fitting for circuit breakers in public branch panelsAgency Information:Conform to standards NF C 62-921, EN IEC 60269RoHS Compliant DimensionsCatalogue NumbersDomestic FusesVolts:-440V acAmps:-15 - 60A (Cylindrical fuses)-30 - 90A (Fuse size 00)IR -20kA (size 10x38)-32kA (size 14x51, 22x58, 00)23For Product Data Sheets, visit Class gG400 - 690V / 0.5 - 125A Sizes:8x31,10x38,14x51,22x58SpecificationsDescription:Cylindrical fuses for gG Industrial protection (general applications). Available with or without indicators and visual fuse activationindicator. Striker fitted to activate an auxiliary contact.Ratings:Applications:Protection of electrical distributioncircuits and electrical appliances (with the exception of electrical motors)Agency Information:EN IEC 60269RoHS Compliant DimensionsVolts:-400, 500, 690V ac Amps:-0.25 - 125AIR -20kA - 400V ac (size 8 x 31)-120kA - 400 and 500V ac -80 kA - 690V acCatalogue Numbers24*UP: Unit PackingFor Product Data Sheets, visit Class aM400 - 690V / 0.16 - 125A Sizes:8 x 31,10 x 38,14 x 51,22 x 58SpecificationsDescription:Cylindrical fuses for aMindustrial protection range (protection of motors).Available in types without indicators, with visual fuse activation indicator and plunger for activation of an auxiliary contact. Ratings:Applications:Direct protection of motorsAgency information:Conform to standard EN IEC 60269RoHS Compliant DimensionsCatalogue NumbersVolts:-440, 500, 690V ac Amps:-0.16 - 125AIR -20kA - 400V ac (size 8 x 31)120kA - 400 and 500V ac 80kA - 690VacNeutral Cartridges25*UP: Unit PackingLow Voltage Fuse Links Catalogue For Product Data Sheets, visit CHD250 - 400V / 10 - 32ASizes:8x23,10x25,8x3110x31,10x38SpecificationsDescription:Fuse Holder for domestic cylindrical fuses. Secured to DIN rail and available with lightindicator for active fuse function. Range as single-pole and single-pole plus neutral in one module. Ratings:Applications:Protection for power lines, heating circuits, lighting circuits. electrical domestic appliances and domestic electricity metersAgency Information:NF C 62203, EN IEC 60269-3,NF marking on all modelsModular Domestic Fuse HoldersVolts:-250V ac (8x31, 10x25)-400V ac (8x31, 10x31, 10x38)Amps:-10 - 32AIR -6kA (6x23, 8x23, 10x25)-20kA (8x31, 10x31, 8x36, 10x38)Catalogue NumbersUP: Unit Packing26For Product Data Sheets, visit CHM690V / 25 - 32A Sizes:8x31,10x38SpecificationsDescription:Fuse Holder forcylindrical industrial fuses. Secured toDIN rail and available with and without light indicator for active fuse function. Range as multi-pole and single-pole plus neutral fuse holders in one module. Accessories for the assembly of modules.Ratings:Applications:Protection of industrial electrical distribution circuits and electrical appliancesAgency Information:EN IEC 60269-3, EN IEC 60947DimensionsCylindrical Industrial FusesVolts:-690V ac Amps:-25 - 32ACatalogue NumbersCatalogue Number27For Product Data Sheets, visit Cylindrical Industrial FusesCH690V / 50 - 125ASizes:14 x 51,22 x 38SpecificationsDescription:Fuse Holders forcylindrical industrial fuses. Secured to DIN rail and screwed. Availablewith and without light indicator for active fuse function and with auxiliary contact for use with plunger fuses.The auxiliary contact is available in two versions: one for the detection of fuse actuation and pre-disconnected,and the other fuse actuation only.Ratings:Applications:Protection of industrial circuits and electrical appliances.Agency Information:EN IEC 60269-3, EN IEC 60947Dimensions 14 x 51Volts:-690V ac Amps:-25 - 32ACatalogue NumbersCatalogue Numbers22 x 5828*UP: Unit Packing*UP: Unit PackingFor Product Data Sheets, visit NH Fuses - Dual IndicatorClass gG - Low Power Loss 400V / 2 - 630ASizes 000,00,01,1,02,2,03,3SpecificationsDescription:Low Power Loss NH Fusesfor industrial protection, gG range (generalprotection). Dual Indicator system for fuse operation function (in the body and in the side plate). Version with voltage free metal gripping lugs for insulated fuses. The components used are lead and cadmium free. Fuses subject to HRC recycling commitment.Ratings:Applications:Protection of large electric distribution networks, cables and distribution boards where theminimization of power losses is a requirement. Electrical utilities and electrical distribution networksStandards and Approvals:Conform to standards EN IEC 60269, VDE 0636, DIN 43620, VDE approval.Dimensions:see page 35Catalogue Numbers29Volts:-400V ac Amps:- 2 - 630AIR -120kA - 400V acData Sheets:720097 / 720099For Product Data Sheets, visit NH Fuses - Dual IndicatorClass gG - Low Power Loss 500V / 2 - 1600ASizes C00,0,1,2,3,4,4ASpecificationsDescription:Low Power Loss NH Fusesfor industrial protection, gG range (general protection). Dual Indicator system for fuseoperation function (in the body and in the side plate) except for the sizes 4 & 4A. Version with voltage free metal gripping lugs for insulated fuses. The components used in manufac-ture are lead and cadmium free. Fuses subject to HRC recy-cling commitment.Ratings:Applications:Protection of large electric distribution networks, cables and distribution boards (except motors)where the minimize of power losses is a requirement. Standards and Approvals:Conform to standards EN IEC 60269, VDE 0636, DIN 43620, VDE approval.Dimensions:see page 35Catalogue Numbers30Volts:-500V ac Amps:- 2 - 1600AIR -120kA - 500V ac-50kA - 250V dcData Sheets:2142For Product Data Sheets, visit Class gG690V / 2 - 630ASizes 000,00,0,1,2,3SpecificationsDescription:NH Fuses for gG range industrial protection (generalprotection). Double indicator system for fuseoperation (in the body and in the side plate). Version with voltage free metal gripping lugs for insulated fuses. The components used in manufacture are lead and cadmium free. Fuses subject to HRC recycling commitment.Ratings:Applications:Protection of electrical distribution circuits,cables and electrical appliances (with the exception of motors).Standards and Approvals:Conform to standards EN IEC 60269, VDE 0636, DIN 43620.Dimensions:see page 35NH Fuses - Dual IndicatorCatalogue Numbers* Contact Cooper Bussmann for availibility** Interrupting Rating for the 35 A size 000 is 80kA31Volts:-690V ac Amps:- 2 - 630AIR -120kA - 690V acLow Voltage Fuse Links Catalogue NH Fuses - Dual IndicatorClass aM 500 - 690V / 2 - 630A Sizes 000, 00, 0, 1, 2, 3ACatalogue NumbersaM Rated Dual Indicator Unit Current voltage conducting voltage free metal Packing (A) gripping lugs gripping lugs 2 4 6NHM000B-690 10NHM000B-690 16NHM000B-690 20NHM000B-690 25NHM000B-690 32NHM000B-690 35NHM000B-690 40NHM000B-690 50NHM00B 63NHM00B 80NHM00B 100NHM00B 160NHM00B 6NHM0B 10NHM0B 16NHM0B 20NHM0B 25NHM0B 32NHM0B 35NHM0B 40NHM0B 50NHM0B 63NHM0B 80NHM0B 100NHM0B 63NHM1B-690 80NHM1B 100NHM1B 125NHM1B 160NHM1B 200NHM1B 224NHM1B 250NHM1B 125NHM2B-690 160NHM2B-690 200NHM2B-690 224NHM2B-690 250NHM2B-690 315NHM2B-690 355NHM2B-690 400NHM2B 315NHM3B-690 355NHM3B-690 400NHM3B-690 500NHM3B-690 630NHM3B 6NHM000BI-690 10NHM000BI-690 16NHM000BI-690 20NHM000BI-690 25NHM000BI-690 32NHM000BI-690 35NHM000BI-690 40NHM000BI-690 50NHM00BI 63NHM00BI 80NHM00BI 100NHM00BI 160NHM00BI 63NHM1BI-690 80NHM1BI 100NHM1BI 125NHM1BI 160NHM1BI 200NHM1BI 224NHM1BI 250NHM1BI 125NHM2BI-690 160NHM2BI-690 200NHM2BI-690 224NHM2BI-690 250NHM2BI-690 315NHM2BI-690 355NHM2BI-690 400NHM2BI 315NHM3BI-690 355NHM3BI-690 400NHM3BI-690 500NHM3BI-690 630NHM3BI 3 3 3 3 3SizeSpecifications Description: NH Fuses for aM range industrial protection (general protection). Double indicator system for fuse operation (in the body and in the side plate). Version with voltage free metal gripping lugs for insulated fuses. The components used in manufacture are lead and cadmium free. Fuses subject to HRC recycling commitment. Ratings: Volts: - 690V ac Amps: - 25 - 32A IR - 80 kA - 500Vac (sizes 000,00 - up to 100A) - 120kA - 500Vac/690Vac Applications: Protection of electrical motors. Standards and Approvals: Conform to standards EN IEC 60269, VDE 0636, DIN 43620. Dimensions: see page 350 0006 10 16 20 25 32 35 40 50 00 63 80 100 160 6 10 16 20 25 32 35 40 50 63 80 100 50 63 80 1 100 125 160 200 224 250 63 80 100 125 2 160 200 224 250 315 355 400 250 315 3 355 400 500 630332For Product Data Sheets, visit Low Voltage Fuse Links Catalogue NH FusesClass aM 500V / 2 - 630A Sizes C00, 0, 1, 2, 3Catalogue NumbersSize Rated current (A) 2 4 6 10 C00 16 20 25 32 40 50 63 80 00 100 125 160 32 50 63 80 100 125 160 40 50 63 80 1 100 125 160 200 250 100 125 160 200 250 315 355 400 315 3 400 500 630 Voltage conducting gripping lugs 2NHC00M 4NHC00M 6NHC00M 10NHC00M 16NHC00M 20NHC00M 25NHC00M 32NHC00M 40NHC00M 50NHC00M 63NH00M 80NH00M 100NH00M 125NH00M 160NH00M 32NH0M 50NH0M 63NH0M 80NH0M 100NH0M 125NH0M 160NH0M 40NH1M 50NH1M 63NH1M 80NH1M 100NH1M 125NH1M 160NH1M 200NH1M 250NH1M 100NH2M 125NH2M 160NH2M 200NH2M 250NH2M 315NH2M 355NH2M 400NH2M 315NH3M 400NH3M 500NH3M 630NH3M 120kA 3 120kA 3 120kA 3 120kA 3 Disconnect Power (kA) Unit PackingSpecifications Description: NH Fuses for aM range industrial protection (general protection). Indicator for fuse activation in the side panel. The components used in manufacture are lead and cadmium free. Fuses subject to HRC recycling commitment. Ratings: Volts: Amps: IR -500V ac 2 - 630A 120kA - 500Vac 50kA - 250V dcApplications: Protection of direct starter motors Standards and Approvals: Conform to standards EN IEC 60269, VDE 0636, DIN 43620. Dimensions: see page 350120kA32120kA3For Product Data Sheets, visit 33Low Voltage Fuse Links Catalogue NH Fuses with StrikerClass gG - aM 500 - 690V / 63 -1250A Sizes 1, 2, 3, 4Catalogue NumbersRated Current (A) 63 80 100 1 125 160 200 224 250 125 160 200 224 250 315 355 400 315 3 355 400 500 630 500 4 630 800 1000 1250 gG Voltage conducting metal gripping lugs 63NHG1BS-690* 80NHG1BS-690* 100NHG1BS-690* 125NHG1BS-690* 160NHG1BS-690* 200NHG1BS-690* 125NHG2BS-690* 160NHG2BS-690* 200NHG2BS-690* 224NHG2BS-690* 250NHG2BS-690* 315NHG2BS-690* 315NHG3BS-690* 355NHG3BS-690* 400NHG3BS-690* 500NHG3BS-690* 630NHG3BS-690* 500NH4G-S 630NH4G-S 800NH4G-S 1000NH4G-S 1250NH4G-S aM Voltage conducting metal gripping lugs 63NHM1BS-690* 80NHM1BS-690* 100NHM1BS-690* 125NHM1BS-690* 160NHM1BS-690* 200NHM1BS-690* 224NHM1BS-690* 250NHM1BS-690* 125NHM2BS-690* 160NHM2BS-690* 200NHM2BS-690* 224NHM2BS-690* 250NHM2BS-690* 315NHM2BS-690* 355NHM2BS-690* 400NHM2BS-690* 400NHM3BS-690* 500NHM3BS-690* 630NHM3BS-690* 3 3 3 Pack QtySizeSpecifications Description: NH Fuses for industrial applications class gG and aM with integrated side striker for visual or remote indication of the fuse status. To be used with NH fuse holders fitted with micro-switch. Ratings: Volts: Current IR 500V ac Size 4 690V ac Size 1,2,3 63A - 1250A 120kA - 500V ac 80kA - 690V ac23Applications: Protection of electrical distribution circuits (Class gG) and motor protection (Class aM) Standards and Approvals: Conform to standards EN IEC 60269, VDE 0636, DIN 43620.* Contact Cooper Bussmann for availibility34For Product Data Sheets, visit 。

相关文档
最新文档