Installing the cNODE Modem Embed cables Procedure 1Connect the transducer cable.
If you have a cable kit,the wires are already connected to the connectors.2Prepare 8wires with the appropriate length for the modem interface.3Install a crimp terminal in one end of each cable.
4Install the crimp terminals in a Molex 8–pin receptacle according to the cable drawing.5Connect J3to P3on the top of the PCB.
6Prepare 2red and 2black wires with the appropriate length for the power.7Install a crimp terminal in one end of each cable.
8Install the crimp terminals in a Molex 4–pin receptacle according to the cable drawing.9Connect J4to P4in the front on the PCB.
10Prepare 3wires with the appropriate length for the service interface.11Install a crimp terminal in one end of each cable.
12Install the crimp terminals in a Molex 8–pin receptacle according to the cable drawing.13
Connect J5to P5in the front on the PCB.
Installing the transducer cables TD80V
Prerequisites
Procedure 1Use one yellow wire (0.5mm 2)and connect the white wire from the transducer with both capacitors and the yellow wire from the transformer.
2
Use one red wire (0.5mm 2)and connect the black wire from the transducer with both capacitors and the red wire from the transformer.
Kongsberg cNODE Modem Embed
Quick Reference
Guide
3Use two black wires(0.5mm2)and connect both to the black wire from the transformer.
4Use two blue wires(0.5mm2)and connect both to the blue wire from the transformer.
5Use two green wires(0.24mm2)and connect both to the green wire from the transducer.
6Use one orange wire(0.24mm2)and connect to the orange wire from the transducer.
7Add crimp terminals to the end of the wires.
8Install the crimp terminals in a Molex8-pin receptacle according to the cable drawing.
a Connect the green wires to pin1and5on the receptacle.
b Connect the black wires to pin3and7on the receptacle.
c Connect the blue wires to pin4and8on the receptacle.
d Connect th
e orange wire to pin6on the receptacle.
This is now receptacle J1.
9Connect receptacle J1to connector P1on the front of the PCB.
Installing the transducer cables TD180
Prerequisites
Procedure
1Use one yellow wire(0.5mm2)and connect the white wire from the transducer with the yellow wire from the transformer.
2Use one red wire(0.5mm2)and connect the black wire from the transducer with the red wire from the transformer.
3Use two black wires(0.5mm2)and connect both to the black wire from the transformer.
4Use two blue wires(0.5mm2)and connect both to the blue wire from the transformer.
5Use two green wires(0.24mm2)and connect both to the green wire from the transducer.
6Use one orange wire(0.24mm2)and connect to the orange wire from the transducer.
7Add crimp terminals to the end of the wires.
8Install the crimp terminals in a Molex8-pin receptacle according to the cable drawing.
a Connect the green wires to pin1and5on the receptacle.
b Connect the black wires to pin3and7on the receptacle.
c Connect the blue wires to pin4and8on the receptacle.
d Connect th
e orange wire to pin6on the receptacle.
This is now receptacle J1.
9Connect receptacle J1to connector P1on the front of the PCB.
Transducer connector pinout J1
This is the pin configuration for a female plug,as seen towards the plug(face view).
Pin number Colour Signal Minimum requirements 1Green ID data0.24mm2
2Screen
3Black TD+0.5mm2
4Blue TD–0.5mm2
5Green ID data0.24mm2
6Orange Ground0.24mm2
7Black TD+0.5mm2
8Blue TD–0.5mm2
Modem interface connector pinout J3
This is the pin configuration for a female plug,as seen towards the plug(face view).
Pin number Signal Minimum requirements
1RS-232Tx0.5mm2
2RS-232Rx0.5mm2
3Ground0.5mm2
Pin number Signal Minimum requirements
4RS-422Tx+0.5mm2
5RS-422Tx–0.5mm2
6RS-422Rx+0.5mm2
7RS-422Rx–0.5mm2
8Ground0.5mm2
Power connector J4
This is the pin configuration for a female plug,as seen towards the plug(face view).
Pin number Colour Signal Minimum requirements 1Red External power(24VDC)0.5mm2
2Red External power(24VDC)0.5mm2
3Black Ground0.5mm2
4Black Ground0.5mm2
Service connector J5
This is the pin configuration for a female plug,as seen towards the plug(face view).
Pin number Signal Minimum requirements
1Not connected
2Not connected
3Not connected
4Ground0.5mm2
5Not connected
6Not connected
7Not connected
8Not connected
9RS-232Tx0.5mm2
10RS-232Rx0.5mm2
Support information
Should you need technical support for your cNODE Modem Embed you must contact a Kongsberg Maritime office.A list of all our offices is provided on our website.You can also contact our main support office in Norway.
Manuals and technical information can be downloaded from our support website.
Company name Kongsberg Maritime AS
Address Strandpromenaden50,3183Horten,Norway
Telephone+4733034100
Telephone24h support+4733032407
Telefax+4733047619
Website https:///maritime/
Support website Product support A to Z
E-mail address****************************。

相关文档
最新文档