ED15M52R0T6X中文资料(Positronic)中文数据手册「EasyDatasheet - 矽搜」
Philips 150S5FS 15 英寸 LCD 显示器说明书
15 inch LCD MonitorPicture/ DisplayCommercial Specifications•LCD Panel Type 1024 x 768 pixels,Anti-glare Polarizer,RGB Vertical Stripe •Panel Size 15"/ 38 cm•Effective Viewing Area 304.1 x 228.1 mm •Pixel Pitch 0.297 x 0.297 mm •Brightness (nits) 250•Contrast Ratio 400:1•Display Colors 16 M•Viewing Angle (C/R > 5) - Horizontal : 160°- Vertical : 140°• Response Time 16 ms• White Chromaticity, 6500º K x = 0.313 / y = 0.329• White Chromaticity, 9300º K x = 0.283 / y = 0.297• Maximum Resolution 1024 x 768 @ 75Hz• Recommended Resolution 1024 x 768 @ 60Hz• Factory Preset Modes 14 modes• User Definable Modes 16 modes• Horizontal Scanning Frequency 30 - 61 KHz• Refresh Rate (V) 56 - 76 Hz• sRGB YesConnectivity• Signal Input Analog (VGA) Convenience• Convenience Enhancements On-screen Display,SmartManage• Monitor Controls Auto, Brightness control,Left/Right, Menu (OK),Power On/Off, Up/Down • OSD Languages English, French, German,Italian, Simplified Chinese,Spanish• Other Convenience Features Kensington Lock• Plug & Play Compatibility DDC/CI, sRGB,Windows 98/ME/2000/XP • Regulatory Approvals CE Mark, E2000, EMC,FCC-B, UL, CSA, MPR-II,Low Emission, NUTEK,Energy Star, SEMKO,TCO '03, TCO '99, TUV/GS,TUV Ergo• Tilt -5° to 25°• VESA Mount 100 mm x 100 mm Accessories• User Manual Yes• Included Accessories AC Power Cord, VGA Cable SmartManageA system for monitoring, managing and checking status of display devices as well as delivering remote support to users who experience difficulties all accomplished over a LAN.Lower power consumptionReduction of the electrical power required to operate a device. Kensington anti-theft lockA security device that fixes the monitor in place to prevent theft. Fast response timeThe amount of time it takes for a liquid crystal cell to go from active (black) to inactive (white) and back to active (black) again.It is measured in milliseconds. Lower numbers mean faster transitions and therefore results in fewer visible image artifacts. XGA, 1024 x 768 resolutionFor graphics monitors, the screen resolution signifies the numberof dots (pixels) on the entire screen. For example, a 1024-by-768 pixel screen is capable of displaying 1024 distinct dots on eachof 768 lines, or about 786 thousand pixels. XGA provides resolutions of 640 by 480 or 1024 by 768 pixels. In addition, XGA allows monitors to be non-interlaced. This ensures a better display performance and accurate color display effect.sRGB readyCalibrated RGB that is optimized for the vast majority of computer peripherals, monitors, operating systems and browsers, allowing accurate color mapping with very little data overhead. Embedded power supplyA power adaptor built into the body of a display device that replaces a bulky external power adaptor.VESA mounting holesA unified industry standard for wall mounting IT equipment set by the Video Electronics Standards Association.FlexiHolderA slim groove that improves efficiency by holding reminder notes, documents, name cards, and photos on the top of monitor to be more efficient..Product HighlightsDimensions• Depth (with base) 180 mm• Height (with base) 344 mm• Width (with base) 342 mm• MTBF 50,000 (excl. CCFL40,000) hrs• Relative Humidity 20 % - 80 %• Temperature Range (Operation) 5°C to 40°C• Temperature Range (Storage) -20°C to 60°C • Weight 2.8 kgPower• Complies With E2000, Energy Star,NUTEK• Consumption 17 W (Typical)• Off Mode < 1 W• Power LED Indicator Operation, Green;Stand by/Sleep,Amber• Power Supply Built-in Trademarks owned by Royal Philips Electronics2004 © Royal Philips Electronics - All rights reserved As an Energy Star partner, Philips has determined that this product meets the Energy Star guidelines for energy efficiency.Microsoft and Windows are registered trademarks of Microsoft Corporation.All data subject to change without noticeRelease date: June 2004。
ED15M44SLEZ中文资料(Positronic)中文数据手册「EasyDatasheet - 矽搜」
MD / ED系列
0.135 [3.43] 0.352 [8.94]
对于焊杯触点 ,指定 在步骤 4代码 2
订购信息.
典型型号: ED15M200T2Z
修正公头性和母头性提供偏光螺旋千斤顶. 指定订购信息步骤 7码 T6.
典型型号: MD15M200T6Z
直印刷电路板安装连接器
CODE NUMBER
HDC
6 0.375 [9.53] 0.360 [9.14]
指定订购信息步骤 6代码 F或 Q. F代表铁 素体电感和 Q为铁素体电感与推入式紧固件 .
L 90°印 刷 电 路 板 安 装 连 接 器
铁素体电感酒吧
A
0.135±0.005 [3.43±0.13]
Fixed female jackscrews
六标准连接器变体安排,9,15个提供, 25,29,37和50 触点.每个梅洛-D连接器变种可用 接触终端进行焊杯,包装后,直和90°
印刷电路板安装端子具有三个印刷电路板一个选择
脚印.每欧元-D接口变体可与端子接触 印刷电路板国家为焊杯,包装后直和90°安装 按欧洲标准公制脚印终端.梅洛-D和欧洲-D
钢与锡板;锌板用重铬酸盐密封.其他材料和 可根据要求完成.
尼龙塑料,铜或锡板;锌板用重铬酸盐密封 . 磷青铜或铍铜与锡板.
钢锌板和重铬酸盐密封,或清除锌板.
滑动锁,锁片,钢,镍板.
热塑性UL 94V-0.复合材料,铜或 钢锌板和重铬酸盐密封.
机械特性:
固定触点:
在绝缘体: 耐焊 铁热:
梅洛 -D
欧元 -D
可选壳件
与环球 FLOAT支架 [F]
0.120±0.010 [3.05±0.25]
海克顿198557生产商品说明书
Eaton 198557Eaton Moeller® series Rapid Link - Speed controller, 4.3 A, 1.5 kW, Sensor input 4, AS-Interface®, S-7.4 for 31 modules, HAN Q5, with braking resistanceGeneral specificationsEaton Moeller® series Rapid Link Speed controller1985574015081964321157 mm 270 mm 220 mm 3.42 kg RoHS UL approval IEC/EN 61800-5-1 CE UL 61800-5-1Product NameCatalog NumberEANProduct Length/Depth Product Height Product Width Product Weight Certifications Catalog Notes can be switched over from U/f to (vector) speed control Connection of supply voltage via adapter cable on round or flexible busbar junction Diagnostics and reset on device and via AS-Interface Four fixed speeds integrated PTC thermistorParameterization: drivesConnect mobile (App) Parameterization: drivesConnectDiagnostics and reset on device and via AS-Interface Parameterization: FieldbusParameterization: KeypadSelector switch (Positions: REV - OFF - FWD)Key switch position HANDPC connectionPTC thermistor monitoringInternal DC linkIGBT inverterFour fixed speedsControl unitBreaking resistanceKey switch position AUTOTwo sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operationThermo-click with safe isolationKey switch position OFF/RESETBraking resistance4-quadrant operation possibleBrake chopper with braking resistance for dynamic braking IP65NEMA 121st and 2nd environments (according to EN 61800-3)IIISpeed controllerASIAS-Interface profile cable: S-7.4 for 31 modulesC1: for conducted emissions onlyC2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.2000 VCenter-point earthed star network (TN-S network)AC voltagePhase-earthed AC supply systems are not permitted.Vertical15 g, Mechanical, According to IEC/EN 60068-2-27, 11 ms, Half-sinusoidal shock 11 ms, 1000 shocks per shaftResistance: 57 Hz, Amplitude transition frequency on accelerationResistance: 6 Hz, Amplitude 0.15 mmResistance: 10 - 150 Hz, Oscillation frequencyResistance: According to IEC/EN 60068-2-6Above 1000 m with 1 % performance reduction per 100 m Max. 2000 m-10 °C40 °C-40 °C70 °CFeatures Fitted with:Functions Degree of protectionElectromagnetic compatibility Overvoltage categoryProduct categoryProtocolRadio interference classRated impulse withstand voltage (Uimp) System configuration typeMounting position Shock resistance Vibration AltitudeAmbient operating temperature - min Ambient operating temperature - max Ambient storage temperature - min Ambient storage temperature - maxIn accordance with IEC/EN 50178 < 95 %, no condensation0.4 - 4.3 A, motor, main circuit Adjustable, motor, main circuit < 10 ms, Off-delay < 10 ms, On-delay 98 % (η)4.1 A3.5 mA120 %Maximum of one time every 60 seconds 380 V480 V380 - 480 V (-10 %/+10 %, at 50/60 Hz)Sensorless vector control (SLV) U/f control BLDC motorsSynchronous reluctance motors PM and LSPM motors 0 Hz500 HzFor 60 s every 600 s At 40 °C6.5 AClimatic proofingCurrent limitationDelay timeEfficiency Input current ILN at 150% overload Leakage current at ground IPE - max Mains current distortion Mains switch-on frequencyMains voltage - min Mains voltage - max Mains voltage toleranceOperating modeOutput frequency - min Output frequency - max Overload current Overload current IL at 150% overload45 Hz66 Hz1.5 kW400 V AC, 3-phase480 V AC, 3-phase0.1 Hz (Frequency resolution, setpoint value)200 %, IH, max. starting current (High Overload), For 2 seconds every 20 seconds, Power section50/60 Hz8 kHz, 4 - 32 kHz adjustable, fPWM, Power section, Main circuitCenter-point earthed star network (TN-S network)AC voltagePhase-earthed AC supply systems are not permitted.2 HP≤ 0.6 A (max. 6 A for 120 ms), Actuator for external motor brakeAdjustable to 100 % (I/Ie), DC - Main circuit765 VDC10 kAType 1 coordination via the power bus' feeder unit, Main circuit 24 V DC (-15 %/+20 %, external via AS-Interface® plug)AS-InterfacePlug type: HAN Q5Max. total power consumption from AS-Interface® power supply unit (30 V): 190 mANumber of slave addresses: 31 (AS-Interface®) Specification: S-7.4 (AS-Interface®)C1 ≤ 1 m, maximum motor cable length C2 ≤ 5 m, maximum motor cable length C3 ≤ 25 m, maximum motor cable lengthMeets the product standard's requirements. Meets the product standard's requirements.Rated frequency - minRated frequency - maxRated operational power at 380/400 V, 50 Hz, 3-phase Rated operational voltageResolutionStarting current - maxSupply frequencySwitching frequencySystem configuration type Assigned motor power at 460/480 V, 60 Hz, 3-phase Braking currentBraking torqueSwitch-on threshold for the braking transistorRated conditional short-circuit current (Iq)Short-circuit protection (external output circuits) Rated control voltage (Uc)Communication interfaceConnectionInterfacesCable length10.2.2 Corrosion resistance10.2.3.1 Verification of thermal stability of enclosuresMeets the product standard's requirements.Meets the product standard's requirements.Meets the product standard's requirements.Does not apply, since the entire switchgear needs to be evaluated.Does not apply, since the entire switchgear needs to be evaluated.Meets the product standard's requirements.Does not apply, since the entire switchgear needs to be evaluated.Meets the product standard's requirements.Does not apply, since the entire switchgear needs to be evaluated.Does not apply, since the entire switchgear needs to be evaluated.Is the panel builder's responsibility.Is the panel builder's responsibility.Is the panel builder's responsibility.Is the panel builder's responsibility.Is the panel builder's responsibility.The panel builder is responsible for the temperature rise Rapid Link 5 - brochureDA-SW-drivesConnect - InstallationshilfeDA-SW-drivesConnect - installation helpDA-SW-USB Driver PC Cable DX-CBL-PC-1M5DA-SW-Driver DX-CBL-PC-3M0DA-SW-USB Driver DX-COM-STICK3-KITDA-SW-drivesConnectMaterial handling applications - airports, warehouses and intra-logisticseaton-bus-adapter-rapidlink-speed-controller-dimensions-003.eps eaton-bus-adapter-rapidlink-speed-controller-dimensions-002.eps eaton-bus-adapter-rapidlink-speed-controller-dimensions-004.eps eaton-bus-adapter-rapidlink-speed-controller-dimensions.epsETN.RASP5-4400A31-5120100S1.edzIL034085ZUramo5_v19.dwgrasp5_v19.stpConfiguration to Rockwell PLC for Rapid LinkGeneration Change RA-SP to RASP5Generation change from RA-SP to RASP 4.0Generation change RAMO4 to RAMO5Generation change from RA-MO to RAMO 4.0Generation Change RASP4 to RASP5DA-DC-00004184.pdfDA-DC-00004514.pdfDA-DC-00003964.pdfDA-DC-00004508.pdf10.2.3.2 Verification of resistance of insulating materials to normal heat10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects10.2.4 Resistance to ultra-violet (UV) radiation10.2.5 Lifting10.2.6 Mechanical impact10.2.7 Inscriptions10.3 Degree of protection of assemblies10.4 Clearances and creepage distances10.5 Protection against electric shock10.6 Incorporation of switching devices and components10.7 Internal electrical circuits and connections10.8 Connections for external conductors10.9.2 Power-frequency electric strength10.9.3 Impulse withstand voltage10.9.4 Testing of enclosures made of insulating material10.10 Temperature rise BrochureDisegnieCAD modelIstruzioni di installazione mCAD modelNote per l'applicazione Report di certificazioneEaton Corporation plc Eaton House30 Pembroke Road Dublin 4, Ireland © 2023 Eaton. Tutti i diritti riservati. Eaton is a registered trademark.All other trademarks areproperty of their respectiveowners./socialmediacalculation. Eaton will provide heat dissipation data for the devices.Is the panel builder's responsibility. The specifications for the switchgear must be observed.Is the panel builder's responsibility. The specifications for the switchgear must be observed.The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.10.11 Short-circuit rating10.12 Electromagnetic compatibility10.13 Mechanical function。
艾登5SC UPS产品说明书
Eaton 5SC1500IEaton 5SC UPS, 1500 VA, 1050 W, Input: C14, Outputs: (8) C13,TowerGeneral specificationsEaton 5SC UPS5SC1500I743172045171150 mm210 mm410 mm15.2 kg 2 yearCE Marked TUV IEC/EN 62040-1 UL 1778IEC/EN 62040-2 CEEACcTUVusProduct Name Catalog Number UPC Product Length/Depth Product Height Product Width Product Weight Warranty Compliances Certifications60 HzSine wave1050 W0.7TowerBlackNoC14184 V240 V50 HzEaton Intelligent Power ProtectorUser replaceableLead-acid maintenance-free (replaceable) 97Eaton UPS and battery servicesEaton 5SC UPS - 500/3000VA - DatasheetEaton UPS Services Quick Guide 2021EU DoC Eaton 5SCEaton 5SC UPS - 500i/750i/1000i/1500i - Installation and user manual (multiple languages)Secondary frequency - max Output waveformWattageOutput power factorForm factorEnclosureIncludes network card Input connectionInput voltage - minOutput voltage - max Secondary frequency - min Software compatibility Battery replacement Battery typeEfficiencySpecial features BrochuresCompliance information Manuals and user guidesAutomatic Voltage Regulation (AVR) Delivers clean sinewave outputLCD display for real-timestatus and measurementsReliable and affordable UPSfor tower servers,networking and storageSaves space with a compacttower designFully integrates with EatonIntelligent Power Managersoftware1 USB port + 1 serial port1 USB port + 1 serial portAdvanced BatteryManagement (ABM)technology to increasebattery lifetimeConstruction typeFree standing modelOutput voltage - min220 VColorBlackExtended battery capabilityNoOutput voltage range230 V (+6%/-10%)TopologyLine-interactiveBTU RatingOnline: 211Runtime at half load13 minInput nominal voltage230V default (220/230/240V)Input frequency range45-55 Hz (50 Hz system), 55-65 Hz (60 Hz system)Input voltage - max276 VVoltage typeACBattery managementABM or constant voltage charging method (user selectable), automatic battery test, deep discharge protectionAuto shutdown functionYesNumber of Outputs C138VA rating1500 VAPotential free switch contactNoReceptacle(8) C13Phase (input)1Package contentsUSB cableSerial cable(2) IEC-IEC cablesQuickstart guideSafety instructionsNoise level<40 dB at 1 meterFeed type1Runtime graphView runtime graphUser interfaceLCD DisplayBattery quantity3Voltage230VTemperature range0-90% non-condensingCommunicationUSB port (HID compliant) Serial port (RS232)Relative humidity0-90% non-condensingRack mounting kitNoOutput frequency50/60 HzRuntime at full load5 minType of interfaceOtherPrimary frequency - min45 HzBattery rating12 V / 9 AhTypeUPSOutput nominal voltage230V default (220/230/240V)Expansion slotsNoInput voltage range184-276 VNominal frequency50-60 HzPrimary frequency - max65 HzAltitude2000 mEaton Corporation plc Eaton House30 Pembroke Road Dublin 4, Ireland © 2023 Eaton. All rights reserved. Eaton is a registered trademark.All other trademarks areproperty of their respectiveowners./socialmedia。
摩托车T6S车载管理终端产品手册
摩托车T6S车载管理终端产品手册(版本:V1.0)介绍声明摩托车T6S车载管理终端是速锐得科技根据摩托车、电动车行业、企业精心打造一款集CAN总线、定位、4G、陀螺仪传感等一体车载终端,实现动力控制、数据采集、多种警告等多项功能,通过指定的IP地址或域名,将车辆的数据信息、定位信息、警告信息实时传输到指定数据库,实现了客户远程、轻松、简明对摩托车、电动车管理。
本T6S手册可能包含技术上不准确的地方或印刷错误。
本手册的内容将做不定期的更新,恕不另行通知;更新的内容将会在本手册的新版本中加入。
我司随时会改进或更新手册中描述的产品或程序。
若存在手册中对产品的描述与实物不符,一律以实物为准。
速锐得拥有本手册的最终解释权。
第一章产品图片第二章技术参数2.1 【整机参数】2.2 【4G模块参数】2.3 【GPS定位参数】第三章终端功能说明3.1 【基本功能-定位功能】3.1.1 定位监控包括定时回传、盲区补偿、速度里程统计、区域监控等功能,系统下发定位指令,终端回传包含经度、纬度、速度、总里程、方向、CAN总线及状态信息的数据。
3.1.2 定时监控车载管理终端可以设定某一时刻或某一时间段或按一定时间间隔,将车辆的位置、状态信息发送到指定监控平台中心。
3.1.3 盲区补偿终端在进入网络盲区时,会保存原始数据数据至FLASH,在4G重新上线时会将盲区数据上传平台。
盲区补偿数据最多保存1000条。
3.1.4 弯道补偿车辆在进入弯道时,终端检测到行车方向有一定角度偏差(默认30度),就会增加一条定时回传信息,确保行驶轨迹更精确。
3.1.5 数据检测终端可以实时检测主电电压,总里程、车速、运行时长、动力、氧传感器浓度等并随时上报至后台。
3.1.8 ACC检测终端可以实时检测车辆的ACC状态,建议安装时尽可能连接ACC线,终端通过ACC和G-Sensor的配合,可以提高静态漂移抑制效果,轨迹数据会更完美。
3.2 【基本功能-报警功能】3.2.1 低压报警(适用于12V/24V电瓶)当车上电瓶电压过低时(0-10V或者16-20V),车载终端向监控中心上报低电压报警。
Myron L 6P中文操作说明书(电阻率仪)
一序言感谢您选用麦隆公司最新一代先进的便携式Ultrameter TM6P型多参数水质检测仪。
这款仪器将使您的操作变得非常简单方便。
为了方便起见,在仪器的底部有一简单的介绍及附有一张袖珍卡片,上有仪器的简单操作说明。
注意:电导,电阻和TDS需要校正到250C时的值。
在液晶显示屏的左方,显示KCl,NaCl,442和USER四种类型,他们是用于电导和TDS转换时进行温度校正所选择的对应溶液,溶液类型不同,则相应的温度校正系数不同,以及电导和TDS的转换系数也不同。
溶液的温度高低导致溶液的电导值不一,相应的TDS 值也不一。
一般地,校正溶液的电导时选用KCl,电阻选用NaCl,TDS选用442(自然水)这取决于目前工业发展的水平。
以下是这款原装进口仪器的操作说明。
二操作规范A 操作使用简单1)只需将试样注入一个或多个电极池,就可以读取一个或多个参数值,2)用待测液润洗电导池或pH/ORP电极池三次并重新加液,3)按取要测试的参数键就可以读取参数值,如无按键,则仪器会在15秒后自动关闭,4)读取数值后,要存储该数值,按MS键就可以保存,就这么简单。
B 按键功能1)虽然仪器带有很多的按键,但无论测那一个参数,都只要按取一个键就可以迅速准确的进行测量,2)每个键都有固定程序设计,按一次键,就执行一次程序,3)仪器没有“off”键,在最后一次按键后15秒,仪器自动关闭(在cal模式下,60秒自动关闭),4)一般情况不需要持续按住一个键,按一下就可以。
C 按键的操作1)一般测试按键区上面五个测试键任意一个都可以开启仪器并选择相应的测试类型进入测试模式.选择的测试类型显示在屏幕的底部,参数的单位显示在右面,如在校准或取消更改设置的模式下,按测试键,同样可以进行测试。
2)电导,RES和TDS这三个键可测试在电导池中的溶液的参数值。
注: i 在加入待测液时,要避免有气泡混入电导池里;ii如发现测试时,溶液的选择类型(KCl,NaCl,442和USER)与所测参数不符,则查看“溶液类型选择”一项选择相应溶液类型。
Extech PRC15 电流 电压计ibrador用户指南说明书
GUÍA DEL USUARIOCalibrador de Corriente / VoltajeModelo PRC15IntroducciónGracias por seleccionar el Modelo PRC15 de Extech. Este instrumento se embarca completamente probado y calibrado y con uso apropiado le proveerá muchos años de servicio confiable. Por favor visite el sitio web de Extech Instruments () para descargar la versión más reciente de esta Guía del Usuario. Extech Instruments es una compañía certificada ISO-9001. SeguridadSeñales internacionales de seguridadEsta señal adyacente a otra señal o terminal, indica que el usuario debe referirse al manualpara mayor información.Esta señal, adyacente a una terminal, indica que, bajo uso normal, pueden existir voltajespeligrososDoble aislanteNotas de seguridad∙No exceda la escala de entrada máxima permisible.∙Apague la unidad cuando el dispositivo no esté en uso.∙Quite las baterías del dispositivo si lo va a guardar más de 60 días.∙Nunca deseche las baterías en el fuego. Las baterías pueden explotar o derramar.∙Nunca mezcle tipos distintos de baterías. Siempre instale baterías nuevas del mismo tipo. Precauciones∙El uso inapropiado de este medidor puede causar daños, choque, lesiones o la muerte. Lea y comprenda este manual del usuario antes de operar este medidor.∙Quite siempre los cables de prueba antes del reemplazar la batería.∙Inspeccione la condición de los cables de prueba y el medidor mismo por daños antes de su operación. Repare o reemplace cualquier daño antes de usar.∙Si el equipo es usado en una manera no especificada por el fabricante, la protección suministrada por el equipo puede ser afectada.Descripción del medidor1. Enchufe de entrada adaptador CA2. Pantallayencendido3. Apagado4. Botones de flechas de ajuste de la fuente de salidaSET5. Botón6. Botón UNIT (mA ó %)7. Botón MODO I/O8. MEM (botón memoria STEP "paso")Retroiluminación/CERO9. Botón10. Enchufes de entrada de cables de prueba Disposición de pantalla1. Icono modo FUENTE2. Icono de estado función CERO3. Icono modo MEDICIÓN4. Icono de estado de apagado automático5. Icono de estado de la batería6. Valor modo de medición7. Icono unidades modo de medición8. Ubicación en memoria del registrador de datos9. Valor modo fuente10. Icono unidades modo FuenteTeclado Descripciones y operaciónBOTÓN DE ENCENDIDO Y FUNCIÓN DE APAGADO AUTOMÁTICO1. Use el botón POWER para encender y apagar la unidad, Cuando enciende la unidad, seejecuta una prueba autónoma corta y luego se estabilizará la pantalla.2. Cuando el símbolo de batería parpadea en la pantalla, reemplace la batería tan pronto seapráctico. La batería débil puede causar lecturas imprecisas y operación errática delmedidor.3. Este instrumento está equipado con apagado automático para apagar el medidor despuésde 10 minutos de inactividad. Para desactivar esta función; presione y sostenga el botón(POWER) de encendido hasta que se apague el icono “ATP”.Botón UNITPresione el botón UNIT en la función corriente para seleccionar las unidades mA o % o V o mV en la función voltaje. En el modo MEDICIÓN el voltaje es de escala automática.Botón I/OPresione momentáneamente el botón I/O para seleccionar ya sea la fuente (SOURCE) o medición (MEASURE) (entrada).Botón MODOEn modo MEDICIÓN, presione y sostenga el botón MODE (I/O) durante 1 segundo paraseleccionar la función corriente (mA/%) o voltaje (mV/V). Suelte el botón cuando aparezca la función deseada.BOTÓN (Retroiluminación)Presione el botón retroiluminación para encender o apagar la retroiluminación.CERO () botónEn el modo MEDICIÓN o GENERACIÓN, presione y sostenga el ZERO () botón durante 1 segundo para ajustar el medidor a cero.►◄▼ y ▲BotonesLos botones de flecha se usan para ajustar el valor de salida en modo fuente (SOURCE).1. Seleccione el modo fuente (SOURCE)2. Presione el botón ► o ◄ para seleccionar un digito para ajuste. El cursor subrayadodestella identifica el digito seleccionado.3. Presione el botón ▼ o ▲ para ajustar el valor del digito. Presione y sostenga el botón ▼ o▲ para ajustar rápidamente el valor.Botón SETEl botón SET se usa para pasar entre los 5 valores de salida guardados.1. Seleccione el modo fuente (SOURCE)2. Presione el botón SET y el valor guardado en el sitio 01 de la memoria se tomará comofuente. En la pantalla aparece "MEM.01”3. Cada vez que presione el botón SET pasa por los 5 sitios de memoria.4. Puede usar los botones de flecha para ajustar el valor en cada sitio de memoria.BOTÓN STEP/MEMEl botón "paso" STEP/MEM se usa para pasar automáticamente por los 5 valores de salidaguardados. El medidor se puede ajustar para un ciclo único de los valores guardados o para unciclo continuo.1. Seleccione el modo fuente (SOURCE)2. Presione y SOSTENGA el botón STEP/MEM. En pantalla aparecerá de manera alterna"STEPSS" (ciclo único) "STEPSC" (ciclo continuo). Suelte el botón al ver el modo deseado.3. En modo de ciclo único el medidor producirá (Fuente) la corriente o el voltaje indicado enMEM01 durante 5 segundos. Enseguida el medidor avanzará a MEM02 durante 5segundos. Esto continuará hasta MEM05 y luego regresará pos los sitios de memoria. Elciclo terminará al llegar a MEM01.4. En modo continuo el ciclo continuará hasta que sea detenido a mano.5. Presione momentáneamente el botón MEM para detener el ciclo. En pantalla aparecerábrevemente el indicador “END”.GUARDAR VALORES EN LA MEMORIALos valores predeterminados guardados en los sitios de memoria son:mA % mV V MemoriaLocalizaciónM1 4.00mA 0.0% 0mV 001V M2 8.00mA 25% 500mV 5V1001V M3 12.00mA 50% 1000mV1501V M4 16.00mA 75% 1500mVM5 20.00mA 100% 2000mV 20VPara cambiar los valores en memoria:1. Seleccione el modo fuente (SOURCE)2. Presione el botón SET para seleccionar en la memoria el sitio a cambiar.3. Presione los botones de flecha para ajustar el valor nuevo4. Presione momentáneamente el botón MEM para guardar el valor. El icono del sito enmemoria destella mientras se evalúa el valor.Modos de operaciónModo de operación (entrada) MEDIREn este modo, la unidad medirá hasta 50mADC o 20VCD.1. Encienda el medidor.2. En pantalla aparecerá "MEASURE".3. Presione y sostenga el botón MODE durante 1 segundo para seleccionar mA ó % ó mV4. Conecte el cable de calibración al medidor.5. Conecte el cable de calibración al dispositivo o circuito a prueba.6. Lea la medida en la pantalla LCD.Modo de Operación SOURCE (Fuente)En este modo la unidad puede suministrar corriente hasta 24mACD a 1000 ohmios o voltaje hasta 20.00V La corriente o voltaje se puede suministrar manualmente o en pasos desde la memoria como se explicó previamente.1. Encienda el medidor2. En pantalla aparecerá "MEASURE".3. Presione y sostenga el botón MODE durante 1 segundo para seleccionar mA ó % ó mV4. presione momentáneamente el botón “I/O” para seleccionar fuente (SOURCE).5. Presione el botón UNIT para seleccionar %/ mA o mV / V.6. Conecte el cable de calibración al medidor7. Conecte el cable de calibración al dispositivo o circuito a prueba8. Use los botones de flecha para ajustar el valor de salida deseado en el indicador inferior.El indicador superior indica el valor real de la corriente o voltaje que se suministra. Si lapantalla superior no es igual al valor establecido, ya sea las baterías necesitan serreemplazadas de la impedancia de carga está fuera del rango especificado.Soporte inclinado / ColgadorEl soporte trasero proporciona dos métodos para comodidad en la visualización.1. Tire de la parte inferior del soporte hacia fuera para colocar la unidad sobre una superficieplana para su visualización.2. Tire hacia fuera de las partes inferior y superior del soporte, y luego gire el soporte paracolgar la unidad.Reemplazo de la bateríaCuando el icono de la batería aparece en la pantalla, debe reemplazar las seis pilas AA.El compartimiento de la batería se localiza en la parte posterior del medidor.1. Abra el soporte inclinado, afloje el tornillo cabeza Philips y quite la tapa de la batería.2. Quite y reemplace las baterías, observando la polaridad.3. Reemplace y asegure la tapa de la batería.Usted, como usuario final, está legalmente obligado (Reglamento de baterías) aregresar todas las baterías usadas; ¡el desecho en el desperdicio o basura de lacasa está prohibido! Usted puede entregar sus baterías en los centros de recolecciónde su comunidad o donde sea que se venden las baterías.Desecho: Cumpla las estipulaciones legales vigentes respecto al desecho del dispositivoal final de su vida útil.Recordatorios de seguridad de baterías∙Por favor deseche las baterías responsablemente; siempre observe las normas locales, estatales y federales referentes al desecho de baterías.∙Nunca deseche las baterías en el fuego. Las baterías pueden explotar o derramar.∙Nunca mezcle diferentes tipos de baterías o nuevas y usadas. Siempre instale baterías nuevas del mismo tipo.EspecificacionesEspecificaciones generalesPantallaLCD matriz de puntos Carga Máxima1000 ohmios @ 24mA Tensión del medidor6 baterías AA o adaptador CA Apagado automático El medidor automáticamente se apaga después de 10 minutos deinactividadCapacidad de suministro de corriente 24mACD a 1000 ohmiosImpedancia voltaje de entrada 10k ohmios mínimoTemperatura de operación 5ºC a 40ºC (41ºF a 104ºF)Temperatura de almacenamiento -20o C a 60o C (-4o F a 140o F)Humedad de operación 80% máx. hasta 31°C (87°F) con disminución linear hasta 50% a40°C (104°F)Humedad de almacenamiento < 80%Altitud de operación 2000 metros (7000ft.) máximaDimensiones 159 x 80 x 44mm (6.3 x 3.2 x 1.7")Peso 234 g (8.3 oz.) no bateríasEspecificaciones de escalaModo Función Escala (resolución) Precisión (% de la lectura) Corriente 0 a 50mA (0.01mA) Porcentaje(%)-25 a 230%0.1%) 0 a 1999mV (1mV) MediciónCD Voltaje(escalaautomática)2 a 20V (0.01v) Corriente 0 a 24mA (0.01mA) Porcentaje(%)-25 a 125%0.1%) 0 a 2000mV (1mV)Suministro(fuente) CD Voltaje 0 a 20V (0.01v)± (0.01% + 1 dígito)Copyright © 2013 Extech Instruments Corporación (una empresa FLIR)Reservados todos los derechos, incluyendo el derecho de reproducción total o parcial en cualquier medio.ISO-9001 certified。
艾顿152046产品说明说明书
Eaton 152046Eaton Moeller series xPole - eRB6/M RCBO - residual-current circuit breaker with overcurrent protection. Electronic RCD/MCB, 8A, 10mA, MCB char. curve: B, 1p, RCCB trip char.: AC, UKGeneral specificationsEaton Moeller series xPole - eRB6/M RCBO - residual-current circuit breaker with overcurrent protection1520469008790341946216 mm 72 mm 17.5 mm 0.18 kg CE Marked RoHS conformCE eRBM-8/1/B/001Product NameCatalog Number EANProduct Length/Depth Product Height Product Width Product Weight Compliances Certifications Model Code8 AIs the panel builder's responsibility. The specifications for the switchgear must be observed.Meets the product standard's requirements.Is the panel builder's responsibility. The specifications for the switchgear must be observed.38 ADoes not apply, since the entire switchgear needs to be evaluated.Meets the product standard's requirements.0 kA50 HzIs the panel builder's responsibility.10.01 A40 °C0 W69.5 mm DA-DC-03_eRBMA120500735.pdfIL019095ZUeaton-xpole-combined-mcb-rcd-device-rcbo-packaging-manual-multilingual.pdfeaton-xpole-erb6-rcbo-catalog-ca019049en-en-us.pdfeaton-xpole-erb6-au-rcbo-catalog-ca019052en-en-us.pdfRated operational current for specified heat dissipation (In) 10.11 Short-circuit rating10.4 Clearances and creepage distances10.12 Electromagnetic compatibilityCurrent limiting classAmperage Rating10.2.5 Lifting10.2.3.1 Verification of thermal stability of enclosures Rated short-circuit breaking capacity (EN 60947-2) Frequency rating10.8 Connections for external conductorsNumber of poles (total)Fault current ratingAmbient operating temperature - maxHeat dissipation per pole, current-dependentBuilt-in depthConnectable conductor cross section (solid-core) - min Certifikater InstallationsvejledningKataloger1 mm²10.9.3 Impulse withstand voltageIs the panel builder's responsibility.Number of polesSingle-poleAmbient operating temperature - min-25 °C10.6 Incorporation of switching devices and componentsDoes not apply, since the entire switchgear needs to be evaluated.10.5 Protection against electric shockDoes not apply, since the entire switchgear needs to be evaluated.Equipment heat dissipation, current-dependent3.3 W10.13 Mechanical functionThe device meets the requirements, provided the information in the instruction leaflet (IL) is observed.10.2.6 Mechanical impactDoes not apply, since the entire switchgear needs to be evaluated.10.9.4 Testing of enclosures made of insulating materialIs the panel builder's responsibility.Static heat dissipation, non-current-dependent0 WApplicationSwitchgear for residential and commercial applications10.3 Degree of protection of assembliesDoes not apply, since the entire switchgear needs to be evaluated.Voltage typeACNumber of poles (protected)1Leakage current typeACRated short-circuit breaking capacity (EN 61009-1)10 kAOperating ambient temperature - min-25 °CHeat dissipation capacity0 WRelease characteristicBWidth in number of modular spacings1Power loss3.3 W10.2.3.2 Verification of resistance of insulating materials to normal heatMeets the product standard's requirements.10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effectsMeets the product standard's requirements.Rated short-circuit breaking capacity (EN 61009)10 kAOperating ambient temperature - max40 °CVoltage rating240 V - 240 V10.9.2 Power-frequency electric strengthIs the panel builder's responsibility.Connectable conductor cross section (solid-core) - max25 mm²Degree of protectionIP20Overvoltage categoryIIIPollution degree210.7 Internal electrical circuits and connectionsIs the panel builder's responsibility.Connectable conductor cross section (multi-wired) - min1 mm²Rated impulse withstand voltage (Uimp)4 kV10.10 Temperature riseThe panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.Basic functionCombined RCD/MCB devicesRated current8 AConnectable conductor cross section (multi-wired) - max 25 mm²TypeRCBO10.2.2 Corrosion resistanceMeets the product standard's requirements.Surge current capacity0.25 kA10.2.4 Resistance to ultra-violet (UV) radiationMeets the product standard's requirements.10.2.7 InscriptionsMeets the product standard's requirements.Rated short-circuit breaking capacity (IEC 60947-2)0 kADisconnection characteristicUndelayedProduct applicationSwitchgear for residential and commercial applicationsRated operational voltage (Ue) - max240 VRated insulation voltage (Ui)500 VEaton Corporation plc Eaton House30 Pembroke Road Dublin 4, Ireland © 2023 Eaton. Alle rettigheder forbeholdes. Eaton is a registered trademark.All other trademarks areproperty of their respectiveowners./socialmedia。
Z-15EW22R中文资料(omron)中文数据手册「EasyDatasheet - 矽搜」
Z-@55-M@@@M
(1) (2)(3) (4)
( 1)防滴型 ( 2)铅奥特莱斯
01 15 H2 H G E None S D K K3 Q3 Q Q8 Q22 Q21 L L2 W21 W W3 W32 W4 W44 W78 W52 W22 W2 W25 W49 W54 W2277 M M22 M2 NJ NJS None 55 A55
H (0.25 mm) Model
Z-15H Z-15H-B Z-15HS Z-15HS-B Z-15HD Z-15HD-B
H2 (0.20 mm) Model
Z-15H2 Z-15H2-B
E (1.8 mm) Model
Z-15E Z-15E-B
H (0.25 mm) Model
Z-01H Z-01H-B Z-01HS Z-01HS-B Z-01HD Z-01HD-B
( 5)终端
: 15 A
:0.20(超高灵敏度) 0.25毫米(高感光度, 微负载) :0.5毫米(标准) 1.8毫米(高容量)
( 2)触点间隙
None 19
: VSF : VCT L型 D型 R型
( 3)四通八达 奥特莱斯(见下 图 .)
( 3)执行器
: : : : : : : : : : : : : : : : : : : : : : : : : : : : : : :
--------------------Z-01HW2255 Z-01HW2255-B
面板安装柱塞 面板安装滚轮 柱塞 面板安装交叉 滚轮柱塞 钢板弹簧 辊钢板弹簧 短铰链杆 长铰链杆 铰链杆 短铰链滚轮摇臂
--Z-15GQA55-B5V
--Z-15GQ22A55-B5V
艾特顿198950产品说明书
Eaton 198950Eaton Moeller® series Rapid Link - Speed controllers, 2.4 A, 0.75 kW, Sensor input 4, Actuator output 2, 230/277 V AC, PROFINET, HAN Q4/2, with manual override switchGeneral specificationsEaton Moeller® series Rapid Link Speed controller198950157 mm270 mm 220 mm 3.61 kgUL 61800-5-1 RoHS UL approval CEIEC/EN 61800-5-1RASP5-2422PNT-412R000S1Product NameCatalog NumberProduct Length/Depth Product Height Product Width Product Weight Certifications Catalog Notes Model Code3 fixed speeds and 1 potentiometer speedcan be switched over from U/f to (vector) speed control Connection of supply voltage via adapter cable on round or flexible busbar junction480 VIs the panel builder's responsibility. The specifications for the switchgear must be observed.400 V AC, 3-phase480 V AC, 3-phaseMeets the product standard's requirements.0.75 kW500 VMeets the product standard's requirements.-40 °C380 VSelector switch (Positions: REV - OFF - FWD)Thermo-click with safe isolationKey switch position AUTOKey switch position OFF/RESETControl unitInternal DC linkPTC thermistor monitoringTwo sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operationManual override switchKey switch position HANDPC connectionIGBT inverter2 Actuator outputs0 Hz200 %, IH, max. starting current (High Overload), For 2 seconds Generation change from RA-MO to RAMO 4.0Generation Change RASP4 to RASP5Generation change RAMO4 to RAMO5Generation change from RA-SP to RASP 4.0Configuration to Rockwell PLC for Rapid LinkGeneration Change RA-SP to RASP5Rapid Link 5 - brochureDA-SW-drivesConnect - InstallationshilfeDA-SW-Driver DX-CBL-PC-3M0DA-SW-USB Driver PC Cable DX-CBL-PC-1M5DA-SW-drivesConnect - installation helpDA-SW-USB Driver DX-COM-STICK3-KITDA-SW-drivesConnectMaterial handling applications - airports, warehouses and intra-logistics ETN.RASP5-2422PNT-412R000S1.edzIL034093ZUramo5_v31.dwgrasp5_v31.stpDA-DC-00004184.pdfDA-DC-00004514.pdfDA-DC-00003964.pdfDA-DC-00004508.pdfeaton-bus-adapter-rapidlink-speed-controller-dimensions-005.eps eaton-bus-adapter-rapidlink-speed-controller-dimensions-002.eps eaton-bus-adapter-rapidlink-speed-controller-dimensions-004.eps eaton-bus-adapter-rapidlink-speed-controller-dimensions-003.epsMains voltage - max10.11 Short-circuit ratingRated operational voltage10.4 Clearances and creepage distancesOutput at quadratic load at rated output voltage - max Output voltage - max10.2.3.1 Verification of thermal stability of enclosures Ambient storage temperature - minMains voltage - minFitted with:Output frequency - minStarting current - max Applikasjonsmerknader BrosjyrereCAD model Installeringsinstruksjoner mCAD model SertifiseringsrapporterTegningerevery 20 seconds, Power sectionRated conditional short-circuit current (Iq)10 kAAmbient operating temperature - max40 °CCommunication interfacePROFINET, optionalAssigned motor power at 115/120 V, 60 Hz, 1-phase1 HPOutput frequency - max500 HzSwitching frequency8 kHz, 4 - 32 kHz adjustable, fPWM, Power section, Main circuitFeaturesParameterization: drivesConnectParameterization: drivesConnect mobile (App) Parameterization: FieldbusParameterization: KeypadAmbient operating temperature - min-10 °CBraking current≤ 0.6 A (max. 6 A for 120 ms), Actuator for external motor brakeNumber of HW-interfaces (serial TTY)10.6 Incorporation of switching devices and componentsDoes not apply, since the entire switchgear needs to be evaluated.Nominal output current I2N2.4 A10.2.6 Mechanical impactDoes not apply, since the entire switchgear needs to be evaluated.10.3 Degree of protection of assembliesDoes not apply, since the entire switchgear needs to be evaluated.Product categorySpeed controllerRadio interference classC2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.C1: for conducted emissions onlyHeat dissipation capacity Pdiss0 WRated control voltage (Uc)24 V DC (-15 %/+20 %, external via AS-Interface® plug) 230/277 V AC (external brake 50/60 Hz)Assigned motor power at 460/480 V, 60 Hz, 3-phase1 HPNumber of HW-interfaces (RS-422)Mains current distortion120 %ProtocolPROFINET IO10.9.2 Power-frequency electric strengthIs the panel builder's responsibility.Overvoltage categoryIIIDegree of protectionIP65NEMA 12Ambient storage temperature - max70 °CRated impulse withstand voltage (Uimp)2000 VConnectionPlug type: HAN Q4/2Overload currentAt 40 °CFor 60 s every 600 sFunctionsFor actuation of motors with mechanical brake3 fixed speeds1 potentiometer speedOutput at linear load at rated output voltage - max0.75 kWMains voltage tolerance380 - 480 V (-10 %/+10 %, at 50/60 Hz)Leakage current at ground IPE - max3.5 mAConverter typeU converter10.2.2 Corrosion resistanceMeets the product standard's requirements.Supply frequency50/60 Hz10.2.4 Resistance to ultra-violet (UV) radiationMeets the product standard's requirements.10.2.7 InscriptionsMeets the product standard's requirements.Shock resistance15 g, Mechanical, According to IEC/EN 60068-2-27, 11 ms, Half-sinusoidal shock 11 ms, 1000 shocks per shaftApplication in domestic and commercial area permittedYesNumber of inputs (analog)Number of phases (output)310.12 Electromagnetic compatibilityIs the panel builder's responsibility. The specifications for the switchgear must be observed.10.2.5 LiftingDoes not apply, since the entire switchgear needs to be evaluated.Number of HW-interfaces (RS-485)1Number of HW-interfaces (industrial ethernet)Efficiency97 % (η)System configuration typeAC voltageCenter-point earthed star network (TN-S network)Phase-earthed AC supply systems are not permitted.10.8 Connections for external conductorsIs the panel builder's responsibility.ProtectionFinger and back-of-hand proof, Protection against direct contact (BGV A3, VBG4)Braking voltage230/277 V AC -15 % / +10 %, Actuator for external motor brakeApplication in industrial area permittedYesClimatic proofingIn accordance with IEC/EN 50178< 95 %, no condensation10.9.3 Impulse withstand voltageIs the panel builder's responsibility.Overload current IL at 150% overload3.6 AInput current ILN at 150% overload2.5 ANumber of HW-interfaces (RS-232)Number of inputs (digital)4Current limitation0.2 - 2.4 A, motor, main circuitAdjustable, motor, main circuitCable lengthC2 ≤ 5 m, maximum motor cable lengthC1 ≤ 1 m, maximum motor cable lengthC3 ≤ 25 m, maximum motor cable length10.5 Protection against electric shockDoes not apply, since the entire switchgear needs to be evaluated.Mounting positionVerticalMains switch-on frequencyMaximum of one time every 60 seconds10.13 Mechanical functionThe device meets the requirements, provided the information in the instruction leaflet (IL) is observed.10.9.4 Testing of enclosures made of insulating materialIs the panel builder's responsibility.Heat dissipation per pole, current-dependent Pvid0 WElectromagnetic compatibility1st and 2nd environments (according to EN 61800-3)Resolution0.1 Hz (Frequency resolution, setpoint value)Assigned motor power at 460/480 V, 60 Hz1 HPRelative symmetric net voltage tolerance10 %Rated operational current (Ie)2.4 A at 150% overload (at an operating frequency of 8 kHz and an ambient air temperature of +40 °C)Number of outputs (analog)Rated operational power at 380/400 V, 50 Hz, 3-phase0.75 kWNumber of HW-interfaces (USB)Operating modeU/f controlBLDC motorsSynchronous reluctance motorsSensorless vector control (SLV)PM and LSPM motorsRated frequency - min45 HzDelay time< 10 ms, Off-delay< 10 ms, On-delayNumber of outputs (digital)2Power consumption32 W10.2.3.2 Verification of resistance of insulating materials to normal heatMeets the product standard's requirements.10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effectsMeets the product standard's requirements.Number of HW-interfaces (other)Rated frequency - max66 HzVibrationResistance: 6 Hz, Amplitude 0.15 mmResistance: 10 - 150 Hz, Oscillation frequencyResistance: According to IEC/EN 60068-2-6Resistance: 57 Hz, Amplitude transition frequency on accelerationShort-circuit protection (external output circuits)Type 1 coordination via the power bus' feeder unit, Main circuit10.7 Internal electrical circuits and connectionsIs the panel builder's responsibility.Braking torqueAdjustable to 100 % (I/Ie), DC - Main circuit≤ 30 % (I/Ie)Relative symmetric net frequency tolerance10 %10.10 Temperature riseThe panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.Number of HW-interfaces (parallel)Assigned motor power at 230/240 V, 60 Hz, 1-phase1 HPInterfacesNumber of slave addresses: 31 (AS-Interface®) Specification: S-7.4 (AS-Interface®)Max. total power consumption from AS-Interface® power supply unit (30 V): 250 mANumber of phases (input)3Eaton Corporation plc Eaton House30 Pembroke Road Dublin 4, Ireland © 2023 Eaton. Med enerett.Eaton is a registered trademark.All other trademarks are property of their respectiveowners./socialmedia27.5 W at 50% current and 90% speed 31.8 W at 100% current and 90% speed 33.5 W at 25% current and 50% speed 34.6 W at 50% current and 50% speed 35.1 W at 25% current and 0% speed 36.6 W at 100% current and 50% speed 36.8 W at 50% current and 0% speed 40.7 W at 100% current and 0% speed 2Max. 2000 mAbove 1000 m with 1 % performance reduction per 100 mHeat dissipation at current/speed Number of interfaces (PROFINET)Altitude。
埃尔克斯电子产品的五种型号功能规范说明书
SPECIFICATIONS13Models 7520DT, 7530DT, 7540DT, 7550DT and 7564SAFunctional SpecificationsINPUTVoltage 115/230 VAC 15, Single Phase, User selection Frequency 50/60 Hz 5Fuse6.3 Amp 250V Slo-Blo for 7550DT and 7564SA 5 Amp 250V Slo-Blo for 75/20/30/40DTDIELECTRIC WITHSTAND TEST MODEOutput Rating5 KV @ 40 mA for 7550DT and 7564SA, 5 KV @ 20mA for 75/20/30/40DT6 KV @ 10 mA DC for 75/30/40/50DT and 7564SAOutput AdjustmentRange:0 - 5 KV AC 0 - 6 KV DCResolution: 1 volt/step Accuracy:(2 of setting 5 volts) Ramp-HI 12mA peak maximum, ON/OFF selectableCharge-LORange:0.0 - 350.0A DC or Auto setHI-Limit AC Range:0.00 - 40.00 mA for 7550DT and 7564SA, 0.00 - 20.00 mA for 75/20/30/40DT Resolution: 0.01 mA/step Accuracy: (2 of setting 2 counts) DC Range:0 - 9999AResolution: 1A/stepAccuracy:(2 of setting 2 counts) LO-Limit AC Range:0.000 - 9.999 mA Resolution: 0.001 mA/stepAccuracy: (2 of setting 2 counts) DC Range:0.0 - 999.9 AResolution: 0.1A/stepAccuracy:(2 of setting 2 counts) Arc Detection Range:1 - 9Failure DetectorAudible and VisualRecycledEquipment(410)email:***************************1981SPECIFICATIONS14Voltage Display Range: 0.00 - 6.00 KV Full Scale0.00 - 5.00 KV Full Scale for 7520DT onlyResolution: 10 volt/stepAccuracy: (2 of reading 2 counts)Current Display Auto RangeAC Range 1: 0.000mA - 3.500mAResolution: 0.001mA/stepRange 2: 3.00 - 40.00 mA for 7550DT and 7564SA,3.00 - 20.00 mA for 75/20/30/40DTResolution: 0.01 mA/stepDC Range 1: 0.0 A - 350.0 AResolution: 0.1A/stepRange 2: 300 A - 3500 AResolution: 1A/stepRange 3: 3000 A - 9990 AResolution: 10A/stepAccuracy: All Ranges (2 of reading 2 counts)DC Output Ripple 4**********************,ResistiveLoad Discharge Time 200 msMaximum CapacitiveLoad DC Mode1uF < 1KV0.75uF < 2KV0.5uF < 3KV0.08uF < 4KV0.04uF < 5KV0.01uF < 6KVAC Output Wave Form Sine Wave, Crest Factor = 1.3 - 1.5Output Frequency Range: 60 or 50 Hz, User SelectionAccuracy: 1%Output Regulation (1 of setting 5 volts) from no load to full load Dwell Timer Range: 0, 0.3 - 999.9 sec (0 = Constant)Resolution: 0.1 sec incrementsAccuracy: (0.1% + 0.05 sec)Ramp Timer Range: AC 0.1 - 999.9 secDC 0.4 - 999.9 secResolution: 0.1 sec incrementsAccuracy: (0.1% + 0.05 sec)RecycledEquipment(410)email:***************************SPECIFICATIONS15Ground Continuity For 75/20/30/40/50DT Current : DC 0.1 A 0.01A, fixedMax. ground resistance : 1 0.1, fixed Ground Fault Interrupt GFI Trip Current: HV Shut Down Speed: 450 A max (AC or DC)< 1msINSULATION RESISTANCE TEST MODE Model 75/30/40/50DT, 7564SAOutput VoltageRange:100 - 1000 Volts DC Resolution: 1 volt/step Accuracy:(2 of reading 2 volts) Short Circuit Current Maximum: 12mA peak Voltage DisplayRange: 0 - 1000 VResolution: 1 volt/stepAccuracy:(2 of reading 2 counts) Resistance DisplayRange: 1 - 9999 M (4 Digit, Auto Ranging)Resolution:500VDC 1000VDC M M M 0.001 1.000 - 5.388 1.000 - 9.999 0.01 1.40 - 53.88 2.80 - 99.99 0.1 14.0 - 538.8 28.0 - 999.9 1104 - 9999280 - 9999Accuracy:(2 of reading 2 counts) at test voltage 500 - 1000V and 1 - 1000 M(8 of reading 2 counts) at test voltage 500 - 1000V and 1000 - 9999 M(8 of reading 2 counts) at test voltage 100 - 500V and 0 - 1000 MCharge-LO Range: 0.000 - 3.500A or Auto Set HI-Limit Range: 0 - 9999 M (0 = Off) LO-Limit Range: 1 - 9999 MDelay TimerRange: 0, 0.5 - 999.9 sec (0 = Constant) Resolution: 0.1 sec/stepAccuracy:(0.1% + 0.05 sec)Ground Fault InterruptGFI Trip Current:HV Shut Down Speed:450 A max (AC or DC) < 1msRecycledEquipment(410)email:***************************SPECIFICATIONS16GROUND BOND TEST MODE Model 7564SA onlyOutput Voltage Range: 3.00 - 8.00 Volts AC (Open Circuit Limit) Resolution: 0.01 volt/stepAccuracy: (2 % of Setting + 0.03V ) O.C. Condition Output Frequency Range: 60 or 50 Hz, User Selection Accuracy: 1%Output CurrentRange: 3.00 - 30.00 Amps AC Resolution: 0.01 Amp/stepAccuracy :(2 % of Setting + 0.02 A) Current DisplayRange: 0.00 - 30.00 Amps Resolution: 0.01 Amp/stepAccuracy:(3 % of Reading + 0.03 A) Resistance DisplayRange: 0 - 600 m Resolution: 1 m /stepAccuracy:(2 % of Reading + 2 m ) HI-LimitRange: 0 - 600 m for 3 - 10 A 0 - 150 m for 3 - 30 A Resolution: 1 m /stepAccuracy:(2 % of Setting + 2 m ) LO-LimitRange: 0 - 600 m for 3 - 10 A 0 - 150 m for 3 - 30 A Resolution: 1 m /stepAccuracy:(2 % of Setting + 2 m ) Dwell TimerRange: 0, 0.5 - 999.9 sec (0 = Constant) Resolution: 0.1 sec/step Accuracy:(0.1% + 0.05 sec)Milliohm OffsetMax. Offset Capability: 200 mResolution: 1 m / stepAccuracy:(2 % of Setting + 2 m )RecycledEquipment(410)email:***************************SPECIFICATIONS17GENERAL SPECIFICATIONSPLC Remote Control Input - Test, Reset, Recall memory 1, 2 and 3Output - Pass, Fail, Test-in-ProcessMemory Allows storage of up to 50 groups different test programsand 8 step/each memory. Step is not available on 7520DT SecurityProgrammable password lockout capability to avoid unauthorized access to test set-up program. LCD Contrast Setting 9 ranges set by the numeric keys on the front panel. Buzzer Volume Setting 10 ranges set by the numeric key on the front panel.Calibration Software and adjustments are made through front panel. Mechanical Bench or rack mount with tilt up front feet. Dimension7540DT, 7550DT and 7564SA:(W x H x D) 17 x 5.8 x 20.3 in. (432 x 147 x 515 mm) 7520DT and 7530DT:(W x H x D) 17 x 5.8 x 12 in. (432 x 147 x 305 mm)Weight7564SA without scanner 52.5 lbs (24 Kgs) 7564SA with built-in scanner 57.0 lbs (26 Kgs) 7550DT without scanner 50.5 lbs (23 Kgs) 7550DT with built-in scanner 55.0 lbs(25 Kgs) 7540DT with 4 port scanner 39.6 lbs (18 Kgs) 7540DT with 8 port scanner41.8 lbs(19 Kgs) 7530DT scanner not available 24.8 lbs (11.27 Kgs) 7520DT scanner not available 24.8 lbs(11.27 Kgs)Scanner Port Two Port Maximum including the built-in scanner. Not available on 7520DT, 7530DT and 7540DT.Scanner Built-in OptionHigh Voltage x 4 Ports (7540DT only)High Voltage x 8 Ports (75/40/50DT and 7564SA) Ground Bond x 8 Ports (7564SA only)RecycledEquipment(410)email:***************************。
艾茨顿ESR5安全关联器说明说明书
Eaton 118701Eaton ESR5 Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling pathsEspecificaciones generalesEaton ESR5 Safety relay 1187014015081168415114.5 mm 99 mm 22.5 mm 0.218 kgUL Category Control No.: NKCR; NKCR7Certified by UL for use in Canada CSA-C22.2 No. 14-95 IEC 62061 ULCSA Class No.: 3211-83; 3211-03 UL File No.: E29184 IEC 61508, Parts 1-7 EN ISO 13849-1 EN 50178 2014/30/EU IEC/EN 60204 CE UL 508UL report applies to both US and CanadaMachines 2006/42/EGESR5-NO-41-24VAC-DCProduct NameCatalog Number EANProduct Length/Depth Product Height Product Width Product Weight CertificationsModel CodeScrew connection4 Non-delayed enable current pathsAutomatic startReinforced insulation6 kV between input circuit / NC contacts, and enable current pathsManual startSafe insulationBasic insulationFeedback circuitApproval for TÜVDetachable clampsStart inputApproval according to UL1-channelEnclosure: Polyamide (PA), not reinforcedContacts: silver tin oxide, gold plated (AgSnO2, 0.2 µ m Au)M3 screw terminals140 mA, AC65 mA, DCIP20Installation location: ≥ IP54Terminals: IP20Enclosure: IP20100 %According to EN 61000-6-4According to EN 61000-6-2Status indication of SmartWire-DT network: Green LED 10,000,000 OperationsBasic deviceRail mounting possibleTop-hat rail fixing (according to IEC/EN 60715, 35 mm) 22.5 mmIII2Normally 5.16 WElectronic safety relaysElectric connection type FeaturesFitted with:FunctionsMaterial Connection type Current consumption Degree of protection Duty factorEmitted interference Interference immunity LED indicator Lifespan, mechanical ModelMounting method Mounting width Overvoltage category Pollution degree Power lossProduct category ProtectionFinger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)4000 V AC1000 msLevel cSIL 1, Safety integrity level, In accordance with IEC 61508 SILCL 1, Safety integrity level claim limitCat. 1, Category4.05 x 10-10, PFHd, Probability of failure per hourModule used to safely interrupt electrical circuitsMonitoring of position switchesMonitoring of emergency-stop circuitsSafety relay for monitoring emergency stop and protective door switchMax. 0.5 Hz, Input dataAC/DC As required240 Months (High Demand)167 Months (Low Demand)3 A at 3600 O/h, AC-15 at 230 V, Outputs0.4 W4 A at 360 O/h, AC-15 at 230 V, OutputsIn accordance with IEC 60947-5-1, Outputs4 A at 360 O/h, DC-13 at 24 V, Outputs2.5 A at 3600 O/h, DC-13 at 24 V, Outputs10 - 150 Hz, Amplitude: 0.15 mm, Acceleration: 2 g, (IEC/EN 60068-2-6)795 - 1080 hPa (operation)Max. 2000 m-20 °C55 °C-40 °C70 °CDry heat to IEC 60068-2-2Damp heat, constant, to IEC 60068-2-3Clearance in air and creepage distances according to EN 50178, UL 508, CSA C22.2, No. 14-95Condensation: Non-condensingRated impulse withstand voltage (Uimp) Recovery timeSafety performance level (EN ISO 13849-1) Safety parameter (IEC 62061)Stop category (IEC 60204)Suitable forSwitching frequencyTypeVoltage type Mounting positionProoftestSwitching capacityVibration resistanceAir pressureAltitudeAmbient operating temperature - min Ambient operating temperature - max Ambient storage temperature - min Ambient storage temperature - max Climatic proofingEnvironmental conditionsOperating temperature - minEmergency stop category 0; emergency switching off Feedback circuitProtective door-20 °C 55 °C< 75 %2 x (0.2 – 1) mm², solid1 x (0.25 – 2.5) mm², flexible with ferrule2 x (0.25 – 1) mm², flexible with ferrule 24 - 12 AWG, solid or stranded1 x (0.2 – 2.5) mm², solid7 mm0.6 x 3.5 mm, Terminal screws2, Terminal screw, Pozidriv screwdriver 0.6 Nm, Screw terminals0.025 - 6 A1.6 W (DC operated)3.4 W (AC operated 50/60 Hz) 0 V26.4 V20.4 V24 V0 V24 V250 V24 V AC/DC (power supply) 1500 VA, max., resistive load (τ = 0 ms), at 250 V AC 42 W max., inductive load (τ = 40 ms), at 24 V DC 88 W max., resistive load (τ = 0 ms), at 220 V DC 288 W max., resistive load (τ = 0 ms), at 48 V DC 144 W max., resistive load (τ = 0 ms), at 24 V DC42 W max., inductive load (τ = 40 ms), at 220 V DC 42 W max., inductive load (τ = 40 ms), at 48 V DC 110 W max., resistive load (τ = 0 ms), at 110 V DC 42 W max., inductive load (τ = 40 ms), at 110 V DC∞ ms, Simultaneity for inputs 1/265 AOne- and two-channel4Operating temperature - maxRelative humidityTerminal capacityStripping length (main cable)Screwdriver sizeTightening torqueInrush currentPower supply circuitRated control supply voltage (Us) at AC, 50 Hz - min Rated control supply voltage (Us) at AC, 50 Hz - max Rated control supply voltage (Us) at AC, 60 Hz - min Rated control supply voltage (Us) at AC, 60 Hz - max Rated control supply voltage (Us) at DC - minRated control supply voltage (Us) at DC - max Rated insulation voltage (Ui)Rated operational voltage Breaking powerInputNominal currentNumber of inputsNumber of outputs (safety related, delayed) with contact Number of outputs (safety related, undelayed) with contact Number of outputs (signaling function, delayed) with contact230 V ACApprox. 24 V DC at input, starting and feedback circuit2.3 A, Input dataShort-circuit proof, 24 V, Fuse for control circuit supply, Control circuitMiniature circuit-breaker with characteristic C: 24 V AC/DC 6 A, For output circuits, ExternalFuse 6 A gL/gG, For output circuits, External6 A, Output fuse, Output data 122 Ω (input and starting circuits for UN)65 ms typ. (K1, K2 - for UN automatic mode) 20 ms typ.72 A² (ITH² = I1² + I2² + I3² + I4²)45 ms22 Ω (impedance)250 V6 A N/O, Limiting continuous current3 A N/C, Limiting continuous current0 W0 W0 W0 A5.16 WMeets the product standard's requirements. Meets the product standard's requirements. Meets the product standard's requirements.eaton-safety-relays-esr5-safety-relay-characteristic-curve-009.eps eaton-safety-relays-esr5-safety-relay-characteristic-curve-008.epseaton-safety-relays-relay-esr5-safety-relay-dimensions-002.eps eaton-safety-relays-relay-esr5-safety-relay-3d-drawing.eps eaton-general-esr5-safety-relay-symbol.epseaton-general-technology-esr5-safety-relay-symbol.epsDA-CE-ETN.ESR5-NO-41-24VAC-DCeaton-safety-relays-esr5-safety-relay-wiring-diagram-005.eps eaton-safety-relays-esr5-safety-relay-wiring-diagram-004.eps eaton-safety-relays-esr5-safety-relay-wiring-diagram-006.epsDA-DC-00004584.pdfDA-DC-00004576.pdfShort-circuit currentShort-circuit protection Short-circuit protection rating Number of outputs (signaling function, undelayed) with contact Permissible total cable resistancePick-up timeQuadratic summation currentReset timeResistanceSwitching voltageUninterrupted currentEquipment heat dissipation, current-dependent PvidHeat dissipation capacity PdissHeat dissipation per pole, current-dependent PvidRated operational current for specified heat dissipation (In) Static heat dissipation, non-current-dependent Pvs10.2.2 Corrosion resistance10.2.3.1 Verification of thermal stability of enclosures10.2.3.2 Verification of resistance of insulating materials to normal heat Characteristic curve DibujoseCAD model Esquemas eléctricosInformes de certificaciónMeets the product standard's requirements.Meets the product standard's requirements.Does not apply, since the entire switchgear needs to be evaluated.Does not apply, since the entire switchgear needs to be evaluated.Meets the product standard's requirements.Does not apply, since the entire switchgear needs to be evaluated.Meets the product standard's requirements.Does not apply, since the entire switchgear needs to be evaluated.Does not apply, since the entire switchgear needs to be evaluated.Is the panel builder's responsibility.Is the panel builder's responsibility.Is the panel builder's responsibility.Is the panel builder's responsibility.Is the panel builder's responsibility.The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.IL05013028ZDA-CS-esr5_no41_nz21 DA-CD-esr5_no41_nz2110.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects10.2.4 Resistance to ultra-violet (UV) radiation10.2.5 Lifting10.2.6 Mechanical impact10.2.7 Inscriptions10.3 Degree of protection of assemblies10.4 Clearances and creepage distances10.5 Protection against electric shock10.6 Incorporation of switching devices and components10.7 Internal electrical circuits and connections10.8 Connections for external conductors10.9.2 Power-frequency electric strength10.9.3 Impulse withstand voltage10.9.4 Testing of enclosures made of insulating material10.10 Temperature rise10.11 Short-circuit rating Instrucciones de montaje mCAD modelEaton Corporation plc Eaton House30 Pembroke Road Dublin 4, Ireland © 2023 Eaton. All Rights Reserved. Eaton is a registered trademark.All other trademarks areproperty of their respectiveowners./socialmediaIs the panel builder's responsibility. The specifications for the switchgear must be observed.Is the panel builder's responsibility. The specifications for the switchgear must be observed.The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.10.12 Electromagnetic compatibility10.13 Mechanical function。
拓普测量ES-50系列全站仪使用手册说明书
内含锂离子电池 锂离子电池报废时必须回收或者正确处理。
:这是日本测量仪器制造厂商协会的标志。
ii
如何阅读本说明书
符号约定
本说明书使用下列符号和约定:
[观测]等 {ESC}等 <放样>等
:表示操作前应阅读的注意事项和重要内容。 :表示参见的章节及其名称。 :表示补充说明。 :表示某个特别术语或操作的说明。 :表示所显示的软键内容。 :表示 ES 操作键盘上的操作键。 :表示显示界面名称。
关于本说明书的约定
· 除特殊说明外,本说明书中的“ES”表示ES-52/55。 · 本说明书中所用显示界面均来自ES-52仪器。 · 说明书界面中所采用的软键功能菜单均为出厂时的默认值,软键功能菜单可由用户
自行改变。
什么是软键:“4.1仪器部件名称”和软键自定义“30.3键功能定义”
· 在阅读各测量操作章节之前,请先阅读“5.基本操作”的内容,了解仪器的基本操 作方法。
· 有关参数设置项的选取和数据输入方法,参见“5.1键盘基本操作”。
· 说明书中介绍的测量程序均采用“连续测量”模式。选取其它测量模式时的操作程
序信息将随
给出。
·
表示该功能/选项并非所有的产品都具有。关于您的产品是否具有,请联系您当
地的代理商。
· KODAK为柯达公司注册商标。
· 本说明书中出现的其它公司或产品名称均为相应公司商标或注册商标。
轻松测量普及型全站仪 使用手册
ES-50 系列
ES-52 ES-55
测量仪器
ES-50 系列
3R 级激光产品
使用手册
· 感谢您选购ES-52/55全站仪。在本说明书中,除特殊说明外,ES即指ES-52/55全站 仪。
欧姆瑞斯电子产品说明书
Dimensions: [mm]sectional drawing A-A744732221744732221744732221744732221T e m p e r a t u r eT T T 744732221Cautions and Warnings:The following conditions apply to all goods within the product series of WE-TI of Würth Elektronik eiSos GmbH & Co. KG:General:•This electronic component was designed and manufactured for use in general electronic equipment.•Würth Elektronik must be asked for written approval (following the PPAP procedure) before incorporating the components into any equipment in fields such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network, etc. where higher safety and reliability are especially required and/or if there is the possibility of direct damage or human injury.•Electronic components that will be used in safety-critical or high-reliability applications, should be pre-evaluated by the customer. •The component is designed and manufactured to be used within the datasheet specified values. If the usage and operation conditions specified in the datasheet are not met, the wire insulation may be damaged or dissolved.•Do not drop or impact the components, the component may be damaged.•Würth Elektronik products are qualified according to international standards, which are listed in each product reliability report. Würth Elektronik does not warrant any customer qualified product characteristics beyond Würth Elektroniks’ specifications, for its validity and sustainability over time.•The customer is responsible for the functionality of their own products. All technical specifications for standard products also apply to customer specific products.Product specific:Soldering:•The solder profile must comply with the technical product specifications. All other profiles will void the warranty.•All other soldering methods are at the customers’ own risk.Cleaning and Washing:•Washing agents used during the production to clean the customer application might damage or change the characteristics of the wire insulation, marking or plating. Washing agents may have a negative effect on the long-term functionality of the product. Potting:•If the product is potted in the costumer application, the potting material might shrink or expand during and after hardening. Shrinking could lead to an incomplete seal, allowing contaminants into the core. Expansion could damage the components. We recommend a manual inspection after potting to avoid these effects. Storage Conditions:• A storage of Würth Elektronik products for longer than 12 months is not recommended. Within other effects, the terminals may suffer degradation, resulting in bad solderability. Therefore, all products shall be used within the period of 12 months based on the day of shipment.•Do not expose the components to direct sunlight.•The storage conditions in the original packaging are defined according to DIN EN 61760-2.•The storage conditions stated in the original packaging apply to the storage time and not to the transportation time of the components. Packaging:•The packaging specifications apply only to purchase orders comprising whole packaging units. If the ordered quantity exceeds or is lower than the specified packaging unit, packaging in accordance with the packaging specifications cannot be ensured. Handling:•Violation of the technical product specifications such as exceeding the nominal rated current will void the warranty.•Applying currents with audio-frequency signals might result in audible noise due to the magnetostrictive material properties. •Due to heavy weight of the components, strong forces and high accelerations might have the effect to damage the electrical connection or to harm the circuit board and will void the warranty.•Please be aware that products provided in bulk packaging may get bent and might lead to derivations from the mechanical manufacturing tolerances mentioned in our datasheet, which is not considered to be a material defect.•The temperature rise of the component must be taken into consideration. The operating temperature is comprised of ambient temperature and temperature rise of the component.The operating temperature of the component shall not exceed the maximum temperature specified.These cautions and warnings comply with the state of the scientific and technical knowledge and are believed to be accurate and reliable.However, no responsibility is assumed for inaccuracies or incompleteness.Würth Elektronik eiSos GmbH & Co. KGEMC & Inductive SolutionsMax-Eyth-Str. 174638 WaldenburgGermanyCHECKED REVISION DATE (YYYY-MM-DD)GENERAL TOLERANCE PROJECTIONMETHODTRi003.0002021-04-25DIN ISO 2768-1mDESCRIPTIONWE-TI Radial Leaded Wire WoundInductor ORDER CODE744732221SIZE/TYPE BUSINESS UNIT STATUS PAGEImportant NotesThe following conditions apply to all goods within the product range of Würth Elektronik eiSos GmbH & Co. KG:1. General Customer ResponsibilitySome goods within the product range of Würth Elektronik eiSos GmbH & Co. KG contain statements regarding general suitability for certain application areas. These statements about suitability are based on our knowledge and experience of typical requirements concerning the areas, serve as general guidance and cannot be estimated as binding statements about the suitability for a customer application. The responsibility for the applicability and use in a particular customer design is always solely within the authority of the customer. Due to this fact it is up to the customer to evaluate, where appropriate to investigate and decide whether the device with the specific product characteristics described in the product specification is valid and suitable for the respective customer application or not.2. Customer Responsibility related to Specific, in particular Safety-Relevant ApplicationsIt has to be clearly pointed out that the possibility of a malfunction of electronic components or failure before the end of the usual lifetime cannot be completely eliminated in the current state of the art, even if the products are operated within the range of the specifications.In certain customer applications requiring a very high level of safety and especially in customer applications in which the malfunction or failure of an electronic component could endanger human life or health it must be ensured by most advanced technological aid of suitable design of the customer application that no injury or damage is caused to third parties in the event of malfunction or failure of an electronic component. Therefore, customer is cautioned to verify that data sheets are current before placing orders. The current data sheets can be downloaded at .3. Best Care and AttentionAny product-specific notes, cautions and warnings must be strictly observed. Any disregard will result in the loss of warranty.4. Customer Support for Product SpecificationsSome products within the product range may contain substances which are subject to restrictions in certain jurisdictions in order to serve specific technical requirements. Necessary information is available on request. In this case the field sales engineer or the internal sales person in charge should be contacted who will be happy to support in this matter.5. Product R&DDue to constant product improvement product specifications may change from time to time. As a standard reporting procedure of the Product Change Notification (PCN) according to the JEDEC-Standard inform about minor and major changes. In case of further queries regarding the PCN, the field sales engineer or the internal sales person in charge should be contacted. The basic responsibility of the customer as per Section 1 and 2 remains unaffected.6. Product Life CycleDue to technical progress and economical evaluation we also reserve the right to discontinue production and delivery of products. As a standard reporting procedure of the Product Termination Notification (PTN) according to the JEDEC-Standard we will inform at an early stage about inevitable product discontinuance. According to this we cannot guarantee that all products within our product range will always be available. Therefore it needs to be verified with the field sales engineer or the internal sales person in charge about the current product availability expectancy before or when the product for application design-in disposal is considered. The approach named above does not apply in the case of individual agreements deviating from the foregoing for customer-specific products.7. Property RightsAll the rights for contractual products produced by Würth Elektronik eiSos GmbH & Co. KG on the basis of ideas, development contracts as well as models or templates that are subject to copyright, patent or commercial protection supplied to the customer will remain with Würth Elektronik eiSos GmbH & Co. KG. Würth Elektronik eiSos GmbH & Co. KG does not warrant or represent that any license, either expressed or implied, is granted under any patent right, copyright, mask work right, or other intellectual property right relating to any combination, application, or process in which Würth Elektronik eiSos GmbH & Co. KG components or services are used.8. General Terms and ConditionsUnless otherwise agreed in individual contracts, all orders are subject to the current version of the “General Terms and Conditions of Würth Elektronik eiSos Group”, last version available at .Würth Elektronik eiSos GmbH & Co. KGEMC & Inductive SolutionsMax-Eyth-Str. 174638 WaldenburgGermanyCHECKED REVISION DATE (YYYY-MM-DD)GENERAL TOLERANCE PROJECTIONMETHODTRi003.0002021-04-25DIN ISO 2768-1mDESCRIPTIONWE-TI Radial Leaded Wire WoundInductor ORDER CODE744732221SIZE/TYPE BUSINESS UNIT STATUS PAGE。
瑞士时间 RM-1500 电子漏计说明书
5. Installation of WindowTM Application Software (RM-1501)........................ 14
b. Cut off a piece of reflective tape of size 1.0 cm x 1.4 cm (optimal size)
c. Wipe off oil or stains from the surface where reflective tape will be adhered.
TABLE OF CONTENTS
1. SPECIFICATIONS ...................................................................................... 1
2. PANEL FUNCTIONS ................................................................................... 2
0.04% ±2 dgts
m/min
2.000 - 2999.9 0.001/0.01/0.1 0.04% ±2 dgts
ft/min
6.00 - 10000 0.01/0.1/1
0.04% ±2 dgts
yard/min
4.00 - 3000
0.01/0.1/1
0.04% ±2 dgts
Event Counter:
艾特顿新型实态超载保护器(SSOL)产品介绍说明书
C440 – OverviewEaton’s new solid-state overload relay (SSOL) is the most compact, high featured, economical product in its class. Designed on a global platform, the new SSOL covers the entire power control spectrum including NEMA, IEC and DP contactors. The NEMA and DP versions are offered with the C440 designation while the IEC offering includes the XTOE version. The electronic design provides reliable, accurate andvalue driven protection, and communications capabilities in a single compact device. It is the fl exible choice for any application requiring easy-touse, reliable protection.• Reliable, accurate, solid-state motor protection • Easy to select, install and maintain• Compact size and fl exible, intelligent design•Global product offering—available with NEMA, IEC and DP power controlC440 Electronic Overload RelayC440 Electronic Overload Relays for Direct Mount to Freedom Series ContactorsFor Use with1–5C440A1A005SF004–20C440A1A020SF000CN15BN3_B0.33–1.65C440A1A1P6SF01–5C440A1A005SF04–20C440A1A020SF01CN15DN3_B0.33–1.65C440A1A1P6SF11–5C440A1A005SF14–20C440A1A020SF19–45C440A1A045SF12CN15GN3_B1–5C440A1A005SF24–20C440A1A020SF29–45C440A1A045SF23CN15KN3_20–100C440B1A100SF3C440 Electronic Overload Relays with Ground Fault for DirectMount to Freedom Series ContactorsFor Use with1–5C440A2A005SF004–20C440A2A020SF000CN15BN3_B0.33–1.65C440A2A1P6SF01–5C440A2A005SF04–20C440A2A020SF01CN15DN3_B0.33–1.65C440A2A1P6SF11–5C440A2A005SF14–20C440A2A020SF19–45C440A2A045SF12CN15GN3_B1–5C440A2A005SF24–20C440A2A020SF29–45C440A2A045SF23CN15KN3_20–100C440B2A100SF3C440 Electronic Overload Relays for Separate MountNotesCN15 contactor listed is non-reversing with a 120 Vac coil. For more options, see Tab 33 in the Controls Catalog.Starters available with 60–300A CTs and C440A1A005SAX overload relay.OverloadFrame Overload Relay With Ground FaultEaton Corporation Electrical Group1000 Cherrington Parkway Moon Township, PA 15108United States877-ETN-CARE (877-386-2273)© 2010 Eaton Corporation All Rights ReservedPublication No. TD04200001EMay 2010PowerChain Management is a registered trademark of Eaton Corporation. All other trademarks are property of their respective owners.Quick Selector TD04200001EMay 2010C440 Electronic Overload RelayType AN19/59 Freedom Series StartersType AN19/59 Freedom Series Starters with C440 Electronic Overload Relays Non-Reversing and ReversingType AN19/59 Freedom Series Starters with C440 with Ground Fault Electronic Overload Relays Non-Reversing and Reversing)y l n O s r e t r a t S R V F d n a R N V F ( e g n a R A L F 044Cs e d o C x fif u S l i o C NotesUnderscore (_) indicates coils suffix required, see Coil Suffix table above.Underscore (_) indicates OLR designation required, see Coil Suffix table above.Size 4 and 5 starters available with 60–300A panel mounted CTs. Please use (1–5A) overload relays with these CTs.Starters are not shipped as assembled units.NEMA Size Continuous Ampere Rating Service Limit Current Rating (Amps)Maximum UL Horsepower Three-PoleNon-Reversing Three-Pole ReversingSingle-Phase Three-Phase115V 230V 208V 240V 480V 600V Catalog Number Catalog Number 009111/311-1/21-1/222AN19AN0_ 5E _AN59AN0_ 5E _01821123355AN19BN0_ 5E _AN59BN0_ 5E _12732237-1/27-1/21010AN19DN0_ 5E _AN59DN0_ 5E _2455237-1/210152525AN19GN0_ 5E _AN59GN0_ 5E _390104——25305050AN19KN0_ 5E _AN59KN0_ 5E _NEMA Size Continuous Ampere Rating Service Limit Current Rating (Amps)Maximum UL Horsepower Three-PoleNon-Reversing Three-Pole ReversingSingle-Phase Three-Phase115V 230V 208V 240V 480V 600V Catalog Number Catalog Number 009111/311-1/21-1/222AN19AN0_ 5G _AN59AN0_ 5G _01821123355AN19BN0_ 5G _AN59BN0_ 5G _12732237-1/27-1/21010AN19DN0_ 5G _AN59DN0_ 5G _2455237-1/210152525AN19GN0_ 5G _AN59GN0_ 5G _390104——25305050AN19KN0_ 5G _AN59KN0_ 5G _Suffix Coil Volts and Hertz Suffix Coil Volts and Hertz A 120/60 or 110/50L 380–415/50B 240/60 or 220/50N 550/50C 480/60 or 440/50T 24/60, 24/50D 600/60 or 550/50U 24/50E 208/60V 32/50H 277/60W 48/60J 208–240/60Y48/50K240/50NEMA Size FLA Range 001P60.33–1.65A 020 4.0–20A 005 1.0–5.0A ——01P60.33–1.65A 020 4.0–20A 005 1.0–5.0A ——11P60.33–1.65A 020 4.0–20A 005 1.0–5.0A 0459.0–45A 2005 1.0–5.0A 0459.0–45A 020 4.0–20A ——310020–100A ——。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
0.225 [5.71]
滤波特性
铁素体电感酒吧EMI / RFI噪声抑制
铆装焊盘片与推进式 紧固件磷青铜
直印刷电路板安装连接器
固定母头螺旋顶
IMPEDANCE ATTENUATION [dB]
ATTENUATION*
FREQUENCY *NO-LOAD CONDITION
0.429 [10.90]
0.426 [10.82]
0.429 [10.90]
0.426 [10.82]
0.429 [10.90]
0.426 [10.82]
0.429 [10.90]
DIMENSIONS ARE IN INCHES [MILLIMETERS]. ALL DIMENSIONS ARE SUBJECT TO CHANGE.
安装在印刷电路板: 锁定系统: 机械操作:
尺寸20接触,公头性接触 - 0.040英寸 [1.02毫米]直径.母头性接触 坚固开放式设计.
6磅. [27N] 500°F [260℃]持续时间每10秒 IEC 512-6. 焊杯触点 - 0.042英寸[1.06毫米] 最小孔径为20 AWG [0.5mm ]丝最大. 直印刷电路板安装 - 0.028英寸 [0.71毫米]直径. 90°印刷电路板安装 - 0.028英寸 [0.71毫米]直径所有印刷电路板 脚印. 包裹后 - 0.025英寸[0.64毫米]平方米. 焊杯触点 - 0.042英寸[1.06毫米] 最小孔径为20 AWG [0.5mm ]丝最大. 直印刷电路板安装 - 0.024英寸 [0.60毫米]直径. 90°印刷电路板安装 - 0.024英寸 [0.60毫米]直径为欧洲公制 脚印. 公头壳可以酒窝EMI / ESD接地路径 . 梯形炮弹和偏光螺旋千斤顶.
3
32
36
L
0.150 [3.81]
0.375 [9.53]
0.236 [5.99]
对于直印刷电路板安装
触点 ,在指定码数 订购信息步骤 4.
ØD
0.028 [0.71]
0.028 [0.71]
0.024 [0.61]
铆装隔板与 推入式紧固件 磷青铜
0.010 [0.25]
MIN.
L
固定母头螺旋顶
ØD
0.539 [13.69]
0.422 [10.72]
0.422 [10.72]
0.534 [13.56]
0.534 [13.56]
K ±0.005 [0.13]
0.233 [5.92]
0.243 [6.17]
0.233 [5.92]
0.243 [6.17]
0.230 [5.84]
0.243 [6.17]
可选壳件
与环球 FLOAT支架 [F]
0.120±0.010 [3.05±0.25]
MD / ED系列
Ø0.120±0.005 [Ø3.05±0.13]
安装孔,两个地方 不锈钢外壳(0选项) Ø0.154[3.91]安装孔, 两地(02选项)
0.032 [0.81]
总径向浮动量
[ ] Ø0.086+0.005 Ø2.18+0.13
钢与锡板;锌板用重铬酸盐密封.其他材料和 可根据要求完成.
尼龙塑料,铜或锡板;锌板用重铬酸盐密封 . 磷青铜或铍铜与锡板.
钢锌板和重铬酸盐密封,或清除锌板.
滑动锁,锁片,钢,镍板.
热塑性UL 94V-0.复合材料,铜或 钢锌板和重铬酸盐密封.
机械特性:
固定触点:
在绝缘体: 耐焊 铁热:
梅洛 -D
欧元 -D
芯片中文手册,看全文,戳
专业品质,
静触点
超 小 型 -D连 接 器
FOR庇护室内 /室外环境应用
D-Sub
SOLDER CUP连接器
Fixed female jackscrews
20 AWG max. [0.5 mm ]
Fixed female jackscrew
Fixed male jackscrew
梅洛-D和欧洲-D系列连接器专业品质连接 建议在具有正常通风遮蔽,不腐蚀室内或室外环境中使用器,但没有 温度或湿度控制.这些固定触点连接器符合IEC 807-2,性能级别二尺 寸和性能要求.
梅洛-D和欧洲-D系列连接器采用精密加工触点 被固定在连接器主体内.母头性接触是一个开放式设计接触,精密加工 高强度磷青铜.
MELO-D / EURO-D系列技术特性
材料和表面处理:
绝缘体:
Contacts:
触点电镀:
壳:
安装隔离柱 和支架: 推紧固件: 螺旋千斤顶系统: 振动锁系统: 抽油烟机:
尼龙树脂,UL 94V-0,黑色. 公头触点 - 精密加工黄铜. 母头触点 - 精密加工 高强度磷青铜. 专业演出薄金镍板.可根据客户要求提供 其他结束.
螺旋千斤顶和铆接紧固件用0.120英寸[ 3.05毫米]通孔,和螺纹铆接紧固件440螺纹和尼龙锁紧刀片.
快速安装推入式紧固件和螺纹位置.
螺旋千斤顶和振动锁定系统. 根据IEC 512-5 500次以上.
芯片中文手册,看全文,戳
D-Sub
专业品质,
静触点
超 小 型 -D连 接 器
FOR庇护室内 /室外环境应用
芯片中文手册,看全文,戳
专业品质,
静触点
超 小 型 -D连 接 器
FOR庇护室内 /室外环境应用
D-Sub
尺寸20 触点,固定
专业品质 连接器
MD / ED系列IEC出版物807-2
性能等级二
U.L.认 可 文件# E49351
CSA认 可 文件# LR54219
电信
U.L.文件# 14098
MD / ED系列
0.135 [3.43] 0.352 [8.94]
对于焊杯触点 ,指定 在步骤 4代码 2
订购信息.
典型型号: ED15M200T2Z
修正公头性和母头性提供偏光螺旋千斤顶. 指定订购信息步骤 7码 T6.
典型型号: MD15M200T6Z
直印刷电路板安装连接器
CODE NUMBER
0.494 [12.55]
0.605 [15.37]
0.605 [15.37]
G ±0.010 [0.25]
0.759 [19.28]
0.759 [19.28]
1.083 [27.51]
1.083 [27.51]
1.625 [41.28]
1.625 [41.28]
1.322 [33.58]
1.322 [33.58]
材料:镍锌陶瓷.
0.010 [0.25]最小
SERIES CODE NO.
A
L
MD
32
MD
4
IMPEDANCMED [OHMS]59
0.375 [9.53] 0.240 [6.10]
------
------
------
------
MD
6 0.375 [9.53] 0.360 [9.14]
ED
36 0.375 [9.53] 0.101 [2.57]
1.541 [39.14]
2.088 [53.04]
2.088 [53.04]
1.770 [44.96]
1.770 [44.96]
2.729 [69.32]
2.729 [69.32]
2.635 [66.93]
2.635 [66.93]
B ±0.005 [0.13]
0.643 [16.33]
0.971 [24.66]
WRAP柱连接器
0.025 [0.64] Sq.
0.495 [12.57]
0.720 [18.29]
典型型号: MD15F600T20
DIMENSIONS ARE IN INCHES [MILLIMETERS]. ALL DIMENSIONS ARE SUBJECT TO CHANGE.
-0.000
-0.00
安装孔,两个地方
CONNECTOR VARIANT SIZES
9M 9F 15 M 15 F 25 M 25 F 29 M 29 F 37 M 37 F 50 M 50 F
A ±0.015 [0.38]
1.213 [30.81]
1.213 [30.81]
1.541 [39.14]
系列连接器是可配对,并与所有D类微型连接器符合IEC 807-2和 MIL-DTL-24308兼容.
印刷电路板各式各样安装硬件,电缆支架 抽油烟机和锁定系统,有现货供应.
梅洛-D和欧洲-D系列连接器符合EIA RS-232和RS 449,和CCITT X.24接口连接器需求.
RoHS触点技术 销售细节 . 标准
2.272 [57.71]
2.272 [57.71]
2.178 [55.32]
2.178 [55.32]
H ±0.010 [0.25]
0.422 [10.72]
0.422 [10.72]
0.422 [10.72]
0.422 [10.72]
0.422 [10.72]
0.422 [10.72]
0.539 [13.69]
HDC
6 0.375 [9.53] 0.360 [9.14]
指定订购信息步骤 6代码 F或 Q. F代表铁 素体电感和 Q为铁素体电感与推入式紧固件 .
L 90°印 刷 电 路 板 安 装 连 接 器
铁素体电感酒吧
A
0.135±0.005 [3.43±0.13]
Fixed female jackscrews
0.217 [5.51]