Protective Devices Miniature Circuit Breakers PLN4Catalog1.11EATON CORPORATION CA019074ENProtective DevicesMiniature Circuit Breakers PLN4 (MW)• T op-quality miniature circuit breakers 1P+N with a width of 1 module unit requiring little space for installation• Contact position indicator red - green • Guide for secure terminal connection • C omprehensive range of accessories can be mounted subsequently • Rated currents up to 40 A • Tripping characteristics B, C• R ated breaking capacity 4.5 kA according to IEC/EN 60898-1DescriptionSG157112EATON CORPORATION CA019074EN 3EATON CORPORATION CA019074ENSpecifications | Miniature Circuit Breakers PLN6, PLN4Description• High selectivity between MCB and back-up fuse due to low let-through energy • B usbar positioning optionally above or below • Compatible with standard busbar• Switching toggle in colour designating the rated current • M eets the requirements of insulation co-ordination, distance between con-tacts ³ 4 mm, for secure isolation • 1-pole breaking capacityI cn 1 = 3 kA Accessories:Auxiliary switch for subsequent installation ZP-IHK 286052ZP-WHK 286053Tripping signal switch for subsequent installation ZP-NHK 248437Remote control and automatic switching device Z-FW/LP 248296Shunt trip release ZP-ASA/..248438, 248439Undervoltage releaseZ-USA/..248288-248291Busbars:see capter busbar systemsTechnical DataPLN6, PLN4ElectricalDesign according toCurrent test marks as printed onto the device IEC/EN 60898-1Rated voltage U n 230 VAC Rated frequency50/60 Hz Rated breaking capacity according to IEC/EN 60898-1I cnPLN6 6 kA PLN4 4.5 kA Characteristic B, CBack-up fuse>6 kA max. 100 A gL/gG >4.5 kA max. 80 A gL/gG Selectivity class3Endurance electrical components ³ 8,000 switching operationsMechanical Frame size 45 mm Device height 80 mmDevice width 17.5 mm (1MU for 1+N)Mountingquick fastening with 2 lock-in positions on DIN rail IEC/EN 60715Degree of protectionIP20Upper and lower terminals open-mouthed/lift terminalsTerminal protection finger and hand touch safe, DGUV VS3, EN 50274Terminal capacity1-16 mm 2Connection diagram1+N-poleDimensions (mm)Rated current I n (A)TypeDesignationArticle No.Units per package4.5 kA, Characteristic BSG157116PLN4-B6/1N 26317912/12010PLN4-B10/1N 26318012/12013PLN4-B13/1N 26318112/12016PLN4-B16/1N 26318212/12020PLN4-B20/1N 26318312/12025PLN4-B25/1N 26318412/12032PLN4-B32/1N 26318512/12040PLN4-B40/1N26318612/1201+N-pole4.5 kA, Characteristic CSG157116PLN4-C6/1N 26318912/12010PLN4-C10/1N 26319012/12013PLN4-C13/1N 26319112/12016PLN4-C16/1N 26319212/12020PLN4-C20/1N 26319312/12025PLN4-C25/1N 26319412/12032PLN4-C32/1N 26319512/12040PLN4-C40/1N26319612/1201+N-pole Explanation PLN4:P = xPole , LN = Miniature Circuit Breakers 1P+N, 1MU , 4 = 4.5 kA4EATON CORPORATION CA019074EN5EATON CORPORATION CA019074ENShort-circuit Selectivity PLN4In case of short-circuit, there is selectivity between the miniature circuit breakers PLN4 and the upstream fuses up to the specified values of the selectivity limit current I s [kA] (i. e. in case of short-circuit currents I ks under I s only the MCB will trip, in case of short-circuit currents above this value both protective devices will respond).*) basically in accordance with EN 60898-1 D.5.2.bShort-circuit selectivity Characteristic B towards fuse link DII-DIV *)Short-circuit selectivity Characteristic C towards fuse link DII-DIV *)PLN4DII-DIV gL/gG I n [A]20253550638010060.7 1.2 2.9 4.52) 4.52) 4.52) 4.52)100.60.9 1.9 3.1 4.52) 4.52) 4.52)130.50.7 1.5 2.5 4.52) 4.52) 4.52)160.50.7 1.4 2.3 4.3 4.52) 4.52)200.50.7 1.4 2.2 4.0 4.52) 4.52)250.50.6 1.3 2.0 3.8 4.52) 4.52)320.50.6 1.2 1.8 3.4 4.52) 4.52)40<0.51)0.61.1 1.7 3.1 4.52) 4.52)Short-circuit selectivity Characteristic B towards fuse link D01-D03*)Short-circuit selectivity Characteristic C towards fuse link D01-D03*)PLN4DII-DIV gL/gG I n [A]2025355063801002 1.5 3.8 4.52) 4.52) 4.52) 4.52) 4.52)40.7 1.2 3.3 4.52) 4.52) 4.52) 4.52)60.7 1.1 2.6 4.52) 4.52) 4.52) 4.52)100.50.8 1.7 2.8 4.52) 4.52) 4.52)130.50.7 1.5 2.5 4.52) 4.52) 4.52)160.50.6 1.2 2.0 3.6 4.52) 4.52)200.50.61.2 1.8 3.3 4.52) 4.52)25<0.51)0.6 1.1 1.7 3.0 4.52) 4.52)32<0.51)0.6 1.0 1.6 2.8 4.52) 4.52)40<0.51)0.6 1.0 1.5 2.6 4.0 4.52)PLN4D01-D03 gL/gG I n [A]20253550638010060.60.9 2.5 4.52) 4.52) 4.52) 4.52)100.50.8 1.6 3.4 4.52) 4.52) 4.52)130.50.7 1.3 2.7 4.0 4.52) 4.52)160.50.6 1.3 2.5 3.8 4.52) 4.52)20<0.51)0.61.32.43.64.52) 4.52)25<0.51)0.6 1.2 2.3 3.3 4.52) 4.52)32<0.51)0.6 1.1 2.1 3.0 4.52) 4.52)40<0.51)0.6 1.0 2.0 2.8 4.52) 4.52)PLN4D01-D03 gL/gG I n [A]2025355063801002 1.1 2.0 4.52) 4.52) 4.52) 4.52) 4.52)40.60.9 2.7 4.52) 4.52) 4.52) 4.52)60.60.9 2.3 4.52) 4.52) 4.52) 4.52)100.50.7 1.5 3.0 4.52) 4.52) 4.52)130.50.71.32.7 4.0 4.52) 4.52)16<0.51)0.6 1.1 2.23.14.52) 4.52)20<0.51)0.6 1.1 2.1 2.9 4.52) 4.52)25<0.51)0.5 1.0 2.0 2.7 4.52) 4.52)32<0.51)0.5 1.0 1.9 2.6 4.52) 4.52)40<0.51)0.50.9 1.7 2.3 4.0 4.52)1) Selectivity limit current I sunder 0.5 kA2) S electivity limit current I s = rated breaking capacity I cn of the MCBShort-circuit selectivity Characteristic B towards fuse link NH-00*)Short-circuit selectivity Characteristic C towards fuse link NH-00*)PLN4NH-00 gL/gG I n [A]202532354050638010060.50.91.52.33.24.52) 4.52) 4.52) 4.52)10<0.51)0.7 1.2 1.5 2.0 3.1 3.9 4.52) 4.52)13<0.51)0.6 1.0 1.3 1.7 2.5 3.1 4.52) 4.52)16<0.51)0.6 1.0 1.3 1.6 2.4 2.9 4.52) 4.52)20<0.51)0.50.9 1.3 1.5 2.3 2.8 4.3 4.52)25<0.51)0.50.9 1.1 1.4 2.1 2.6 4.0 4.52)32<0.51)0.50.8 1.0 1.3 1.9 2.4 3.6 4.52)40<0.51)0.50.80.9 1.1 1.7 2.2 3.3 4.52)PLN4NH-00 gL/gG I n [A]202532354050638010020.7 2.1 4.52) 4.52) 4.52) 4.52) 4.52) 4.52) 4.52)40.50.9 1.6 2.6 3.7 4.52) 4.52) 4.52) 4.52)60.50.8 1.4 2.1 2.9 4.52) 4.52) 4.52) 4.52)10<0.51)0.6 1.0 1.4 1.9 2.8 3.5 4.52) 4.52)13<0.51)0.60.9 1.3 1.7 2.5 3.1 4.52) 4.52)16<0.51)0.50.7 1.0 1.3 2.0 2.5 3.8 4.52)20<0.51)0.50.70.9 1.2 1.8 2.3 3.5 4.52)25<0.51)0.50.70.9 1.1 1.6 2.1 3.3 4.52)32<0.51)<0.51)0.60.8 1.1 1.5 2.0 3.1 4.52)40<0.51)<0.51)0.60.8 1.0 1.4 1.9 2.9 4.52)Load Capacity PLN4Let-through Energy PLN4Determined according to 60898-1.Maximum let-through energy PLN4, Characteristic BMaximum let-through energy PLN4, Characteristic CLoad capacity in case of MCB block installationCurrent carrying capacity at ambient temperature (I n = 2-13 A)Permitted permanent load at ambient temperature T (°C) with n devices: I DL = I n K T (T)K N (N).Current carrying capacity at ambient temperature (I n = 16-25 A)Current carrying capacity at ambient temperature (I n = 32, 40 A)Number of devices (n)L o a d c a p a c i t y f a c t o r K N500300500100015002000300040005000600070001000015000800090004009007008006001500100030002000500040002000090007000100008000600015000300005000060000400007000080000prospektiver Kurzschlußstrom [A]D u r c h l a ße n e r g i e I t [A s e c ]22prospektiver Kurzschlußstrom [A]D u r c h l a ße n e r g i e I t [A s e c ]22500300500100015002000300040005000600070001000015000800090004009007008006001500100030002000500040002000090007000100008000600015000300005000060000400007000080000Prospective short-circuit current [A]L e t t h r o u g h e n e r g y I 2t [A 2 s e c ]Prospective short-circuit current [A]L e t t h r o u g h e n e r g y I 2t [A2 s e c ]EatonEMEA Headquarters Route de la Longeraie 71110 Morges, Switzerland Eaton.eu© 2020 EatonAll Rights Reserved Printed in AustriaPublication No. CA019074EN Article number 302799-MK July 2023Grafics: SRA, Schrems9010238178694Eaton Industries (Austria) GmbH Scheydgasse 421210 Vienna AustriaFollow us on social media to get the latest product and support information.Eaton is a registered trademark.All other trademarks are property of their respective owners.To contact us please visit https:///contacts For technical questions please contact your local Eaton team.Changes to the products, to the information contained in thisdocument, and to prices are reserved; as are errors and omissions.Only order confirmations and technical documentation by Eaton is binding. Photos and pictures also do not warrant a specific layout or functionality. Their use in whatever form is subject to prior approval by Eaton. The same applies to trademarks (especially Eaton, Moeller,and Cutler-Hammer). The Terms and Conditions of Eaton apply, as referenced on Eaton Internet pages and Eaton order confirmations.Eaton is an intelligent power management company dedicated toimproving the quality of life and protecting the environment for people everywhere. We are guided by our commitment to do business right, to operate sustainably and to help our customers manage power - today and well into the future. By capitalizing on the global growth trends of electrification and digitalization, we’re accelerating the planet’s transition to renewable energy, helping to solve the world’s most urgent power management challenges, and doing what’s best for our stakeholders and all of society.For more information, visit .。

甘肃容和说明介绍模板(合订本)1之欧阳化创编

甘肃容和说明介绍模板(合订本)1之欧阳化创编

QBZ —60(30)/660(380)矿用隔爆型真空电磁起动器产品使用说明书甘肃容和矿用设备集团有限公司2010.02.22出版1、用途及适用范围QBZ-60(30)/660(380)矿用隔爆型真空电磁起动器(以下简称起动器)选用CKJ真空接触器,使产品分断能力大、电寿命、机械寿命高、噪音小。

起动器适用于具有爆炸危险(甲烷混合物)和煤尘的矿井中,作为就地和远距离控制,交流50HZ,电压至660V的矿用隔爆型三相鼠笼式感应电动机的起动和停止,并在停止时换向。

特别适用具有频繁操作的重载负荷的煤矿机械设备中。

该起动器也可用于具有同类爆炸混合物的工业企业中。

起动器型号含义:2. 执行标准MT111-1998《矿用隔爆型低压交流真空电磁起动器》;Q/RH 013—2008《QBZ-60(30)/660(380)矿用隔爆型真空电磁起动器》。

3. 防爆型式矿用隔爆型; 防爆标志 ExdI .4.工作条件:a 海拔不超过2000M;b 周围介质温度不高于+35℃;c 周围空气相对湿度不大于95% (25℃);d 在无强烈颠簸振动及垂直平面倾斜15°以下的环境中;e 在无足以腐蚀金属和破坏绝缘的气体及蒸汽的环境中;f 无滴水的地方;g 安装类别为三级;h 污染等级3级5、外型尺寸长×宽×高 =445 × 480 ×6156、技术参数6.1 起动器的主要技术数据(见表1).6.2 JDB保护器的特性(见表2).6.3 起动器隔爆性能参数(见表3).表1表2表37.结构、工作原理7.1结构抽屉式本体用橡胶电缆与接线柱连接,便于推拉本体。

a 低压真空接触器用来接通和分断电力线路,并附有两常闭辅助触头用于控制线路,其线圈吸引电压为36V;b JDB电机综合保护器用于电动机的过载、断相、漏电闭锁及短路保护;c RL1—15/2A型熔断器;d KL变压器为660V(380V)/36V双压变压器;e 换向器用于隔离电源及停止时换向;f 控制按扭用于就地控制电动机的起动和停止。

Koolaire K0600控制箱部件清单说明书

Koolaire K0600控制箱部件清单说明书

For more Parts Information:https:///Default.aspxT ABLE OF C ONTENTSK0600PartsK0600 Control Box1 K0600 Evaporator Compartment3 K0600 Refrigeration Compartment5 K0600 Air-cooled Compartment7 K0600 Water-cooled Compartment9 K0600 Panels11#PART #DESCRIPTION QTY Note 1040002007Control Board1a000012211 3.5 amp Ceramic Fuse1b4302253Control Board Mounting Supports2Run Capacitor - See Note for Usage2a000000028Run Capacitor - 208-230V/60 Hz/1 Ph[1]2b2010133Run Capacitor - 50 Hz[2]2c000010711Bracket - Run Capacitor32006599Contactor - 230V/50-60 Hz/1 Ph48373263Refrigeration Service Valve Assembly5000011170Manifold Strainer5a000011055Manifold Strainer - Bracket6000008816High Pressure Cut-out7000010617Control Box8000012138Control Box Cover92501409Bushing - 0.875"102500019Bushing - 1.187"112502189Bushing - 0.625"125202169Screw - #10-24 x 0.50" Ground132007939Toggle Switch14Wiring Harnesses14a000010265Control Box Wiring Harness - 230V/60 Hz/1 Ph14b000010599Control Box Wiring Harness - 230V/50 Hz/1 Ph14c000011182Wiring Harness - Compressor14d000010724Wiring Harness - Toggle Switch14e000010511Wiring Harness - Float Switch to Control Box14f000007185Wiring Harness - Compressor Compartment - Air-cooled14g000007177Wiring Harness - Compressor Compartment - Water-cooledPART NOTES:[1]-60 Hz[2]-50 Hz#PART #DESCRIPTION QTY Note 1000009055Foodzone Seal Panel24008469Evaporator Top Filler Panel2a5202099Screw - #10-24 x 0.50" PHIL37602193Water Distribution Tube - 30" L3a5004799Thumbscrew SS - #8-32 x 0.375"3b5004629O-Ring - 0.125" ID4Evaporator Assembly4a7602839Evaporator - Dice Cube4b7602849Evaporator - Half Dice Cube4c5004619Screw - #12-16 x 0.687"5000012651Ice Thickness Float5a000010630Bracket - Ice Thickness Float6000012649Harvest Float6a000010818Bracket - Harvest Float77602213Water Diverter - 30" Models7a5305123Thumbscrew SS - #8-32 x 0.44"8000010828Water Trough94010979Water Curtain10Water Pump - See Note for Usage10a2007399Water Pump - 230V/60 Hz10b8252109Water Pump - 230V/50 Hz[1] 10d000010244Water Pump Mount10e5004659Water Pump Base O-Ring - 4.00" ID10f5004679Water Pump Outlet O-Ring - 0.875" ID11000010510Magnetic Bin Switch127602203Evaporator Top Frame AssemblyPART NOTES:[1]-230V/50 Hz#PART #DESCRIPTION QTY Note 1Compressor - See Note for Usage1a000010474Compressor - Samsung - 208-230V/60 Hz/1 Ph1b000010464Compressor - Samsung - 230V/50 Hz/1 Ph2Harvest Valve2a000007019Solenoid Valve with Electrical Coil - 208-230V/50-60 Hz2b000005157Danfoss Solenoid Valve Coil Only - 230V/50-60 Hz[1]3Water Dump Valve3a000001768Water Dump Valve - 208-230V/50-60 Hz3b6058459Water Dump Valve Mounting Bracket3c4420383Clear Tubing - 0.625" ID48930259Drier5, 6000003405Insulated Tube[2] 7000012224Expansion Valve7a4013299Valve Insulation Boot - Body8000002719Valve Insulation Boot - Bulb9000012651Ice Thickness Float9a000010630Bracket - Ice Thickness Float10000012649Harvest Float10a000010818Bracket - Harvest Float11000010244Water Pump Mount12Water Pump - See Note for Usage12a2007399Water Pump - 230V/60 Hz12b8252109Water Pump - 230V/50 Hz[3] 138706093Female Wing Adapter - 0.375"148706133Female Wing Adapter - 0.50"150********Water Inlet Valve - 208-230V/50-60 Hz15a4010439Tubing - Water Inlet Valve[4] 15b1360989Connector - Water Inlet Valve165650609Snap Clamp - 1.0" ID175650709Snap Clamp - 0.799"/0.899" ID180********Vinyl Tubing 0.625" ID18a6038831Insulation 0.88 ID X 0.25W X 13.50L191360961Male Connector205650529Clamp - Expansion Valve Bulb213000833Strap - Expansion Valve Bulb - 0.375"225202069Screw - #10-24 x 0.50" HEX23000008346Compressor Base24000011505Terminal Cover24a000011506Terminal Cover Gasket24b000010854Terminal Cover NutPART NOTES:[1]-\pages from 000005156_02.jpg" width=266 height=183>[2]-insulated vinyl tubing from distribution tube to water pump dump valve[3]-230V/50 Hz[4]-\pages from 401043_05.jpg" width=1797 height=2238>#PART #DESCRIPTION QTY Note 13005569Air Filter2000008868Air Condenser3000002485Fan Shroud42416203Fan Blade56061869Fan Motor Bracket62412939Fan Motor 208-230V/50-60 Hz7Fan Motor Mounting7a5033589Mounting - Screw7b000000936Mounting - NutMounting -85202069Screw - #10-24 x 0.50" HEX9000008830Fan Cycle Control#PART #DESCRIPTION QTY Note 18865333Water-cooled Condenser2000010620Water Regulating Valve3000008892Receiver48930259Drier58706083Female Wing Adapter - 0.50"6000010604Receiver Mounting BaseWater Condenser Mounting76000541Receiver Strap85002249Elbow - 0.5" MF x 0.375" MPT95202069Screw - #10-24 x 0.50" HEX105573419Washer115003883Flare Nut - 0.50"#PART #DESCRIPTION QTY Note 1000010523Top Cover2000012139Front Panel3000011271Right Side Panel4000011272Left Side Panel5000007314Air Baffle Assembly63005569Air Filter7000011086Back Panel - Air-cooled8000011092Back Panel - Water-cooled9000010603Back Coupling Panel - Water-cooled/Remote106068649Left Top Channel116062579Right Top Channel12000011100Left Corner Post130********Right Corner Post14000010269Front Top Support150********Bottom Door Frame166067289Rear Connection Box16a6067299Cover - Rear Connection Box172006143Terminal Block - 50 Hz - 3 Pole180********Cartoning。

Rockwell Automation 100-C 700-CF 联用联闸器与安全联闸器产品说明书

Rockwell Automation 100-C 700-CF 联用联闸器与安全联闸器产品说明书

Migration SolutionsBulletin 100-C Contactor and 700-CF RelayCertain variants of our Bulletin 100-C/700-CF contactor and relay products and related 100S/700S-CF safety contactors and relays Mitigate and Eliminate the Risks of Automation ObsolescenceRockwell Automation understands that your contactors and relays are a critical asset in your automation system, and we support that by providing you with the latest technology to maximize your investment. New technologies can improve and extend the operation of existing equipment and provide an immediate boost to productivity. Bymigrating from your legacy 100-C/700-CF contactor and relay products and related 100S/700S-CF safety contactors and relays, you can help to decrease downtime and optimize operations well into the future.We will help you to meet this demand to innovate by proactively planning and managing your transition every step of the way to help you get the highest possible return on your automation investment.*ACTIVE: Most current offering within a product category.ACTIVE MATURE: Product is fully supported, but a newer product or family exists. Gain value by migrating.END OF LIFE: Discontinued date announced – actively execute migrations and last time buys. Product generally orderable until the discontinued date.1DISCONTINUED: New product no longer manufactured or procured.2 Repair/exchange services may be available.1- Outages on specific items may occur prior to the Discontinued date. 2 - Limited stock may be available in run-out mode, regionally.Alternative 100-C contactors and 700-CF control relays or new 100-E contactors and 700-EF control relaysWhy Upgrade or MigrateWith the expansion of theBulletin 100- E contactor and the introduction of the 700-EF relay product lines, Rockwell Automation is discontinuing some variants of our Bulletin 100- C/700-CF contactor and relay products and related 100S/700S-CF safety contactors and relays as of December 2021.Now is the time to migrate to an alternative 100-C line contactor or 700-CF control relay. These represent most of the existing contactor and relay business and should not affect most of our customers. These remaining devices can be used to replace the variants that will be discontinued. For example, the single frequency 24V 50Hz and 24V 60 Hz coil contactors or relays can bereplaced by the dual frequency 24V 50-60 Hz coil devices.For those devices that cannot be replaced by the remaining contactors and relays or for customers looking for a new solution, Rockwell Automation is launching a new line of 100-E contactors below 100 amps and 700-EF control relays.New Product Benefits• Wide range, energy efficient AC/DC coil • Ease of selection and reduced inventory • Minimized power supply requirements • Increased energy efficiency • Simplified engineering effortsThe plan for the various coil voltages and related coil codes is as follows:100-C/700S-CF AC‡Not available on 100/104-C90 or -C97 contactors100-C/700S-CF DCLegendAll 700S-CF safety industrial relays will be discontinued December 2021 and replaced by the new 700S-EF safety industrial relays.The line of bulletin 100-C/700-CF contactors and relays with spring clamp terminals will also be discontinued. If you are using this spring clamp terminal technology now, please consider moving over to screw terminal devices as soon as possible, since supply may be limited.Finally, the line of bulletin 100Q capacitor switching contactors will be discontinued. There will not be a replacement offering for these devices.Here are the products that are affected: 100-C/700-CF AC100-C/700-CF DC**Definition of replacement categories:Direct Replacement (DR): a product that can be used in place of an earlier product without any user modifications or adjustments. A direct replacement provides backward compatible form, fit and function by emulating the earlier product.Functional Replacement (FR): a product or family that can be used to replace an earlier product or family and emulates the old one with minimal changes to an existing application. A functional replacement means that there is a form, fit or function change, but that it is backward compatible.Engineered Replacement (ER): a product or family that can be used to migrate an earlier product or family and requires engineering changes to existing applications. An engineered replacement means that there is a form,fit or function change of the application that is not backward compatible and that does not emulate the earlier product.For More InformationTo better understand your options, contact your local authorized Allen-Bradley distributor or Rockwell Automation sales office or visit: /go/lifecycle and /go/migration.Connect with us.Allen-Bradley, DriveLogix, expanding human possibility, Installed Base Evaluation, Integrated Architecture, PowerFlex, Rockwell Automation, Studio 5000 Logix Designer, TechConnect and TorqProve are trademarks of Rockwell Automation, Inc. Trademarks not belonging toRockwell Automation are the property of their respective companies.Publication MIGRAT-PP047C-EN-P - June 2022 | Supersedes Publication MIGRAT-PP049B-EN-P - August 2021Copyright © 2022 Rockwell Automation, Inc. All Rights Reserved. Printed in USA.。

厦门艾邦电子有限公司 Eaton 9PX UPS 商品说明书

厦门艾邦电子有限公司 Eaton 9PX UPS 商品说明书

Eaton 9PX2200IRTBPEaton 9PX UPS HotSwap IEC, 2200 VA, 2200 W, Input: C20, Outputs: (6) C13, (1) C19, Rack/tower, 3UGeneral specificationsEaton 9PX UPS 9PX2200IRTBP 74317208149048.5 cm 13 cm 44 cm 24.52 kg 2 year CE Marked TUV cULus Listed CSA 22.2FCC part 15 Class B CISPR22 Class B EAC CEENERGY STAR certified IEC/EN 62040-1 UL 1778 IEC/EN 62040-2Eaton 9PX 2200i RT3U HotSwap IECProduct Name Catalog Number UPCProduct Length/Depth Product Height Product Width Product Weight Warranty Compliances Certifications Model CodeView runtime graph Hot-swappable internal batteries and extended battery modules (EBMs)612 V / 7 Ah Sealed, lead-acidYes(6) C13, (1) C19Online/Double-conversion 2200 W 2200 VA Sine wave 230V1230V default (200/208/220/230/240V)200/208/220/230/240 V +/- 1%350/60 Hz 1C20 41.8m230V default (200/208/220/230/240V)176-276 V (100-276 V with derating)Runtime graph Battery management Battery replacementBattery quantity Battery rating Battery type Extended battery capability Receptacle TopologyWattage VA rating Output waveform Voltage Output power factor Output nominal voltageOutput voltage rangeVoltage distortion output (linear load) - max Output frequency Feed type Input connection Input cord length Input nominal voltageInput voltage rangeCommunicationABM & Temperature compensated charging method (user selectable)Automatic battery test Deep discharge protection Automatic recognition of external battery units USB port (HID compliant)Serial port (RS232)Mini terminal block for remote On/Off Mini-terminal block for remote power off Mini-terminal block for output relayDry contacts (3 outputs, 150/60 Hz40-70 Hz>.99One slot for optional communication card NoNoEaton Intelligent Power Manager, Eaton Intelligent Power Protector Multilingual graphical LCD display OtherYes3000 m Online: 488<40 dB at 1 meter 0-96% non-condensing 0° to 40°C (32° to 104°F)Nominal frequency Input frequency range Input power factor Expansion slotsEthernet interfaceIncludes network card Software compatibilityUser interfaceType of interface Potential free switch contact Altitude BTU Rating Noise level Relative humidity Temperature range Special featuresinput, optocoupler, DB9)Double conversion topology Constantly monitors power conditions and regulates voltage and frequency First UPS in its class to provide Unity power factor (VA=W)Energy Star qualified, provides the highest efficiency level to reduce energy and cooling costs Internal bypass allows service continuity in case of UPS faultNext-generation graphical LCD displayCompatible with Virtual environments (VMware, Hyper-V, Citrix Xen, Redhat)Meter energy consumption (down to the managed outletRack/tower3U482.6 mm (19 inch) device Yes93.511YesYes Eaton UPS Services Quick Guide 2021Eaton UPS and battery servicesEaton 9PX 1-3 kVA UPS and 9PX EBM 48V and 72V - Installation and user manualEaton Bypass Power Module (BPM) user guideEaton 9PX 1-3 kVA UPS - Quick Start GuideEaton Specification Sheet - 9PX2200IRTBPEaton 9PX 1000-3000W UPS - DatasheetForm factorRack size Construction type Rack mounting kit Efficiency Package contentsPhase (input) Phase (output) Internal bypass Hot swap power BrochuresManuals and user guidesSpecifications and datasheets Technical data sheetsgroups)Hot swappable batteries Advanced Battery Management (ABM) technology to increase battery lifetimeLong backup time with up to 4 optional EBMUPSInput cableMaintenance Bypass(2) IEC-IEC output cables USB cableSerial cable(2) brackets for 19’ mounting (2) Rack-mounting kit(2) Supports for tower mountingCable locking system Safety instructions Quickstart guideEaton Corporation plc Eaton House30 Pembroke Road Dublin 4, Ireland © 2023 Eaton. All rights reserved. Eaton is a registered trademark.All other trademarks areproperty of their respectiveowners./socialmediaYesAuto shutdown function。

98005C 冷水泉缸 FLEXI-GUARD 安装、维护与使用指南说明书

98005C 冷水泉缸 FLEXI-GUARD 安装、维护与使用指南说明书

98005C (REV. B - 3/05)1SWIRLFLO Refrigerated fountains with FLEXI-GUARDINSTALLATION, CARE & USE MANUALT MT MENOB2-8C ENOB2-8RACfor future reference.NOTE:It is common practice to ground electrical hardware such as telephones, computers and other devices toavailable water lines. This can, however, cause electrical feedback in the plumbing circuit, which results in an “electrolysis” effect occurring in the fountain. This may result in water which has a metallic taste to it or has a noticeable increase in the metallic content of the water.When inspecting plumbing circuit, remember the line may be grounded some distance from the installation,and may occur outside the building or area in which the unit is being installed.This condition can be avoided (in most cases) by using recommended materials during installation. Any drain fittings provided by the installer should be made of plastic which will electronically isolatethe fountainfrom the remainder of the building’s plumbing circuits.A B DL98005C (REV. B - 3/05)298005C (REV. B - 3/05)31. Install chiller: Remove front panel of chiller. Slide chiller onto the shelf and position it to the left as per dimensions in Figure 1.Note: Building construction must allow foradequate air flow on both sides, top and back of chiller. A minimum of 4” (102mm) on both sides and top is required. See chiller installation for additional instructions.2. Attach solenoid valve assembly to the underside of cross member of mounting frame on electronic sensor unit. (See Fig. 7).3.Make water supply connections. Inlet port is marked on the chiller (1/4” O.D. copper tube). Bend the copper tube (provided) at an appropriate length from the chiller toopening in frame. Install the in-line strainer (provided with chiller) by pushing it in until it reaches a positive stop,approximately 3/4” (19mm) on the marked chiller inlet port (See Figs. 3) (Refer to Fig. 13 on page 7 for details on assembling quick connect fittings). Attach an unplated and deburred copper water inlet line and a service stop (not provided) to the chiller. Turn on the water supply and flush the line thoroughly.Caution: DO NOT SOLDER tubes insertedinto the strainer as damage to o-rings may result.4.Make connection between remote chiller outlet tube and solenoid valve assembly. Outlet port is marked on the chiller (1/4” O.D. copper tube). Install a 1/4” tee(provided) on the marked chiller outlet port. Insert one end of 1/4” poly tubing into the tee and the other end into the straight fitting on the solenoid valve assy. (See Fig. 3)5. Hang the upper panel on the mounting frame hanger. Be sure that the panel is engaged with hanger at the top of frame before releasing it. Align holes in the panel with holes in the mounting frame. Install two (2) #10-24 x 5/8” (16mm) screws (Item 27 - Figure 4) in holes and tighten securely.6. Install the fountain. Remove the screw (Item 28) from cover plate (Item 12) and slide cover plate toward basin. Mount the fountain to the upper panel and frame with (4) 5/16” x 1” (25mm) long bolts (Item 30), bracket (Item 34) and nuts (Item 33) provided. Tighten securely. Brackets (Item 34) must be installed as shown to properly support fountain. (See Fig. 5)Special ToolsItemDescription QuantityNONEAdditional MaterialsI tem DescriptionQuantity1Unplated copper inlet pipe 2Service StopREQUIRED TOOLS AND MATERIALSThese tables show special tools and/oradditional materials (not provided) which are necessary to complete installation of these units:Figure 2 - Chiller InstallationCHILLER INLETCHILLER OUTLET222123TO BUBBLER21Figure 3 - ENO Tube Routing98005C (REV. B - 3/05)4Figure 4 - Upper Panel InstallationFigure 5 - Fountain InstallationFigure 6 - Lower Panel Installation7. Attach waste tube (1-1/4” O.D.) to 1-1/4” O.D. slip trap (provided by others).8.Connect the fountain drain waste tube to the building sanitary sewer system. Connection should be made in compliance with local plumbing code requirements. (Note:Plumbing trap is not included with the fountain).9.Make connection between solenoid valve assembly and fountain(s). Insert the 1/4” poly tubing coming from the fountain with sensor into the solenoid valve. Insert the 1/4”poly tubing coming from the fountain with push button into the tee (See Fig. 3).10.Connect power cord of sensor to solenoid valveassembly by running it through the back panel and connecting it to terminal as shown in Fig. 8.11.Turn on water supply and check for leaks. Release airfrom tank by interrupting infrared beam; a steady stream of water assures all air is removed. The sensor has a 30 second maximum ON time. It may be necessary to step away from beam a few times to allow chiller tank to fill.DO NOT SOLDER tubes whileinserted into the strainer as damage to o-rings may result.12.These products are designed to operate on 20-105PSIG supply line pressure. If inlet pressure is above 105PSIG, a pressure regulator must be installed in the supply line.Any damage caused byconnecting these products to a supply line with pressure lower than 20 PSIG orhigher than 105 PSIG IS NOT covered under warran ty.13.Make electrical connections to the chiller. See chillerinstructions.14. Check stream height from bubbler. Stream height isfactory set at 35-40 PSI. If supply pressure varies greatly from this, please do the following. For Push Button units only , remove push button (Item 14 - Figure 12) and adjust thescrew on the regulator (Item 16 - Figure 12). To remove push button, remove set screw from bottom ofsleeve (Item 31). Insert a small punch in screw hole and push up while grasping the push button and pull forward removing the push button. Clockwise adjustment will raise stream height and counterclockwise movement will lower stream height. For best adjustment streamshould hit basin approximately 6-1/2” from the bubbler.Reassemble push button by pushing in on button until the push button catches in the sleeve. Reinstall the set screw (Item 31) in the sleeve (Item 12).For Electronic sensor units only , remove lowerpanel (Item 26 - Fig. 4) and turn adjustment screw on the regulator (Item 16 - Fig. 8). Clockwise adjustment will raise stream height and counterclockwise movement will lower stream height. For best adjustment stream should hit basin approximately 6-1/2” from the bubbler.15. Mount lower panel. Loosen the three (3) #10-24 x 5/8” (16mm) screws (Item 27 - Figure 5) at frame bottom lip. Slide upper tongue of lower panel (Item 26 - Figure 6) under lower edge of already installed upper panel. Tighten previously loosened screws securely. (See Figure 6)30282724, 2527263433View From Rear1198005C (REV. B - 3/05)5163915413445, 46, 4729384048ENOB2-8CFigure 8 - Regulator AssemblyFigure 7 - Solenoid AssemblyENOB2-8RAC29347CONNECT TO FOUNTAIN SENSOR WIRING CONNECTOR98005C (REV. B - 3/05)6See Fig. 1020BUBBLER DETAILNOTE:When installing replacement bubbler and pedestal,tighten nut (Item 5) only to hold parts snug in position. Do Not Overtighten.Basin12345321981811910353743424427366Figure 9 - Exploded ViewFigure 10 - Bubbler Assembly98005C (REV. B - 3/05)7Figure 11 - Fountain Body AssemblyFigure 12 - Push Button Assembly121314151617313220See Fig. 10818See Fig. 10921291019271132Figure 14 – Water Supply ConnectionsDIRECTION (NOT FURNISHED)3/8" O.D. UNPLATED COPPER TUBE CONNECT 1/4" O.D. TUBE Figure 13 – Quick Connect FittingsActuation of Quick Connect Water Fittings: Cooler is provided with lead-free connectors which utilize an o-ring water seal. To remove tubing from the fitting, relieve water pressure, push in on the gray collar while pulling on the tubing. (See Figure 13) To insert tubing, push tube straight into fitting until it reaches a positive stop (approximately 3/4”).49PARTS LISTITEM NO.PART NO.DESCRIPTION1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 4956073C40322C56011C55997C75580C15027C28455C28474C28473C45767C28343C45781C45847C45848C50986C61315C15005C56163C45769C45768C56092C70682C55996C28383C28384C27026C11100834389070432C3841700175560C75632C70817C70020C28395C36207C36193C45813C31376C40045C50203C56082C56204C70022C70644C31272C70817C75507C28454C75671CBubbler AssyOrifice AssyHousing AssemblyPedestalBubbler LocknutBrkt - SwirlflowAssy - Brkt Solenoid/Reg/WireBasin - SwirlflowLower ShellFountain BodyCover PlateSleevePin - Push ButtonPush ButtonHolder - RegulatorRegulatorRetaining NutGasket - DrainAssy - Drain/TailpipeDrain - FerrulePoly Tubing (Cut To Length)Tee - 1/4Strainer (Provided with Chiller)Back Panel RH ADABack Panel LH ADALower PanelScrew - #10-24 x .62 HHSMScrew - #8-32 x .38 THSMScrew - #8-18 x .37 HHSMScrew - 5/16-18 x 1.00 HHMSSetscrew - #10-32 x .31Fttng - Elbow 1/4 x 1/4Nut - Hex 5/16-18Bracket - SupportWire - ExtensionAssy - Sensor EyeSleeve - Swirlflow EECord - Power 115vNut - Hex 1 5/16Bushing - Strain ReliefNut - RegulatorLens - Swirlflow EEScrew - #6-32 x .31 SetScrew - #6-32 x .50 PHMSSolenoid ValveFttng-Elbow 1/4 Stem x 1/4x90Fttng-1/4 NPTF x 1/4ODBrkt -Solenoid/Reg SwirlfloSpring - Push ButtonInstallation PackageThe components for installation are packed in threeseparate boxes, regardless of the type of unit beinginstalled. The boxes contain the following:Box No. 1: Wall Frame(s)Box No. 2: Remote Chiller, ECH8Box No. 3: Fountain Arm and PanelsAdditional materials, as noted in the Parts List, are alsoshipped in these boxes.1. Orifice Assy: Minerals deposits on orifice can cause water flow tospurt or not regulate. Mineral deposits may be removedfrom the orifice with a small round file not over 1/8" diameter or asmall diameter wire. CAUTION: Do not file or cut orifice materials.2. Stream Regulator: If orifice is free of material deposits regulatewater flow according to instructions on page 4.3. Sensor Control: The sensor has a 2 second delay time. If sensorfails to operate valve mechanism or operates erratically, checkthe following:a) Ensure there are no obstructions within a 40 inch radius fromthe front of fountain.b) Check wire connections at the solenoid valve and at the sensor.CAUTION: Make sure unit is unplugged before checking anywiring.c) Ensure proper operation of solenoid valve. If there is an audibleclicking sound yet no water flows, look for an obstruction in thevalve itself or elsewhere in the water supply line.WARNING: Do not expose sensor to direct sunlight.4. Sensor Range Adjustment: The electronic sensor used in thisfountain is factory pre-set for a "visual" range of 36 inches. Ifactual range varies greatly from this, or a different setting is desired,follow the range adjustment procedure below:a) Remove front lens.b) Locate range adjustment screw between the lenses of thesensor, then with a small tip screwdriver, rotate the range adjust-ing screw clockwise to increase range or counter-clockwise todecrease range. 1/4 turn of screw is equal to approximately12 - 18 inches of range.CAUTION: Complete range of sensor (24 - 46 inches) is only oneturn of the adjusting screw.c) Replace lens.TROUBLE SHOOTING AND MAINTENANCECARE AND CLEANING INSTRUCTIONSDO NOT use abrasive or chemical cleaners to clean the sensor lens.They may dull the luster and attack the plastic cover and chromefinish of the fountain. Use ONLY soap and water, then wipe withclean cloth or towel. When cleaning adjacent surfaces, the fountainand the sensor lens should be protected from any splattering ofcleaners. Acid and cleaning fluids can discolor and damage chromeplating and plastic sensor lens. 800-518-538898005C (REV. B - 3/05)8。

博士安全B520辅助电源模块说明书

博士安全B520辅助电源模块说明书

u为防火或防盗应用提供高达2 A 的12 V 待机电流(4 A 的盗警电流)u分别监测多达两个12 V 7-18 Ah 电池(多达36 Ah 的容量)u 提供多达80个小时的待机时间u 方便读取式开关寻址u使用博世标准TR1850插入式变压器B520辅助电源模块是一个辅助电源扩展设备,可通过SDI2总线连接到兼容的报警主机。

此模块受到监测并将所有状态更改传递给报警主机。

工业、商业和机构设施是B520模块的典型安装。

B520地址开关可用于实现轻松设备寻址。

SDI2输出端子为SDI2扩展设备(如键盘)提供辅助电源。

AUX PWR 端子为其他设备(如PIR 移动探测器)提供增强型辅助电源功能。

功能监测监控此模块通过SDI2总线监控并传送有关以下内容的状态信息:•操作(检测信号)•电池1 (BATT 1)•电池2 (BATT 2)•AC 输入电源(AC)•电池电量充足•电池电量不足•电池缺失指示灯•检测信号 [图标]。

当系统正常运行时,蓝色LED 指示灯闪烁亮起和熄灭。

LED 指示灯持续亮起或熄灭指示系统故障。

闪烁三次指示通信故障。

•BATT 1 LED 指示灯。

LED 指示灯呈绿色持续亮起指示BATT 1的电池状态正常工作。

闪烁指示电池电量不足。

闪烁三次指示电池充电器故障。

LED 指示灯熄灭指示电池缺失。

•BATT 2 LED 指示灯。

LED 指示灯呈绿色持续亮起指示BATT 2的电池状态正常工作。

闪烁指示电池电量不足。

闪烁三次指示电池充电器故障。

LED 指示灯熄灭指示电池缺失。

•AC LED 指示灯。

LED 指示灯呈绿色持续亮起指示AC 电源正在工作。

正在执行电池测试时会产生脉冲式LED 指示灯(每秒3个脉冲)。

闪烁指示AC 电源不足或发生故障。

电池充电在AC 电源发生故障的情况下,连接到电池端子的已充满电的电池将为B520提供电源。

如果B520的AC 电源输入发生故障(缺失或电量低),则B520将自动从主电源(AC)切换到备用电源(电池)。

LC09A 方案数据手册说明书

LC09A 方案数据手册说明书

LC09A方案数据手册正式版本:1.0.1发布日期:2022-9-1成都维客昕微电子有限公司目录1产品简介 (2)1.1概述 (2)1.2功能框图 (2)1.3特点 (3)2技术指标 (4)2.1极限电气参数 (4)2.2推荐工作条件 (4)2.3时序参数 (5)2.3.1IIC时序参数 (5)3管脚定义 (6)3.1管脚分布图 (6)3.2管脚定义 (7)4 5交互接口 (7)典型应用框图 (8)5.1典型应用电路 (8)5.25.35.1.1电源选择...........................................................................................................85.1.2复位...................................................................................................................9 LED性能参数及辅料说明 (10)推荐光学设计 (10)6封装外形尺寸 (11)6.1封装示意图 (11)7 8包装信息及湿敏等级说明 (11)SMT回流焊要求 (12)8.1无铅回流焊曲线示意图说明 (12)9修订记录 (13)10联系信息 (14)1 产品简介1.1 概述LC09A 是一款集成了1个物理通道、2个逻辑通道的健康监测传感器芯片,支持日常心率(HR )监测以及佩戴识别功能,并具备低功耗特性、高集成度、高性价比等特点,适用于智能手表、智能手环等可穿戴智能设备。

1.2 功能框图GNDVDDLEDNVCSELIICOSC2MOSC20kBORPOR/FIFOCONTROLADC AFE PD ARRAY DRIVERLASER SDASCLINTVDDIO图1-1 LC09A 功能框图1.3特点⚫超低功耗心率模式典型功耗80μA@ 25Hz,包含LED发光功耗未佩戴功耗:~5μA@1Hz休眠电流:~400nA⚫芯片内置功能自动调光自动佩戴检测⚫内置FIFO64Bytes⚫通信接口IIC时钟最高支持400KHzIIC7位设备地址为0x33⚫关键电气特性VDD:3.0V~3.6VVDDIO: 1.8V~3.6V⚫封装OLGA封装尺寸:1.95mm*1.9mm*0.6mm,8PIN⚫可支持的典型应用心率佩戴检测⚫可测深肤色等级心率:13级(参考[PANTONE Skin Tone Guide])⚫算法占用空间心率算法的空间:25Hz:1.6kRAM,9.8kROM2技术指标2.1极限电气参数※注意:⚫超出极限工作条件可能会对芯片造成永久性损坏;⚫为保证芯片长期处于正常工作状态,请勿将芯片工作在极限参数下,否则会影响芯片可靠性。

朗姆斯 50 60 Hz 电磁闸 产品说明书

朗姆斯 50 60 Hz 电磁闸 产品说明书
CONTACT LIFE: Electrical at rated load = 100,000 cycles. Mechanical = 10,000,000 cycles.
ELECTRONICS MODULE: Solid state components epoxy encapsulated in nylon shell.
NOTES:
1. Connecteions may be made to nonenergy generating or storing hazardous location devices, such as switch contacts, noninductive resistance thermometer detectors (RTD’s) and thermocouples without necessitating a specific approval except when the device is mounted inside a tank subjected to pressure greater than 15 psi.
SPECIFICATIONS
CONTACT DESIGN: D PST: One normally open (N.O.) and one normally closed (N.C.)
CONTACT RATINGS: 8 Amperes resistive load at 250 Volts A.C. and 5 ampheres at 30 Volts D.C.
Use the following chart to determine the limits of run:
Max. Sensitivity (K OHMS) 3.3 4.7 10

AFS96-30-22-11 24-60V50 60HZ 20-60VDC 安全联接器说明书

AFS96-30-22-11 24-60V50 60HZ 20-60VDC 安全联接器说明书
AC-3 1200 cycles per hour AC-15 1200 cycles per hour DC-13 900 cycles per hour
(1000 V) 60 °C 30 A (220 / 230 / 240 V) 25 kW
(380 / 400 V) 45 kW (415 V) 55 kW (440 V) 55 kW (500 V) 55 kW (690 V) 55 kW (400 V) 45 kW
(220 / 240 V) 4 A (24 / 127 V) 6 A (500 V) 2 A (690 V) 2 A
for 0.1 s 140 A for 1 s 100 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1150 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 750 A
AC-1 600 cycles per hour AC-2 / AC-4 150 cycles per hour
3210675
AFS96-30-22-11
2
Container Information
Package Level 1 Units Package Level 1 Width Package Level 1 Depth / Length Package Level 1 Height Package Level 1 Gross Weight Package Level 1 EAN Package Level 2 Units Package Level 2 Width Package Level 2 Depth / Length Package Level 2 Height Package Level 2 Gross Weight Package Level 3 Units

ACR90x0系列产品用户指南说明书

ACR90x0系列产品用户指南说明书
PARCOM PARCOP PARCOM/PARCOP PARCM PARCP
no equivalent
PA PAD
JOG INC X4 JOG INC X4 Y-3
JOG ABS X4
JOG FWD X JOG REV X JOG OFF X
JOG ACC JOG DEC JOG VEL JOG JRK
See Also
PSET
RES REN
Non-Interpolated Motion
Incremental Motion D+4:MC0:MA0:GO1 D+4,-3:MC00:MA00:GO11
Absolute Motion
D:MC0:MA1:GO1
Continuous Motion
D+:MC1:GO1 D-:MC1:GO1 S1
SLIM X2 Y3 SLM X1
SET 16144 : SET 16145 : CLR16146
?BIT16132 ?BIT16133 ?BIT 16130
MSEEK JOG HOME X1 JOG HOME X-1 MSEEK JOG HOMVF JOG ACC JOG JRK JOG DEC SET16152 SET16154 SET16153
6KtoACRcmd_ crossref.xls
Scaling Setup Limits
Homing
6K Command SCLA SCLD SCLV SCLMAS
LH3,1 INFNCn-mR INFNCn-mS INFNCn-mT LHAD100,200
LS2,3 LSNEG -1: LSPOS +1
DIM
?P12295

欧特斯顿9E XL系列10kVA 8kW无线电源说明书

欧特斯顿9E XL系列10kVA 8kW无线电源说明书

Eaton 9E10KIXLSAI Eaton 9E XL, 10 kVA, 8 kW, Entrada: cableada, Salida:cableada, torreEspecificaciones generalesNombre del producto N.º de catálogoSAI Eaton 9E9E10KIXLUPC Longitud/profundidad de producto74317206768561.29 cmAltura del producto Anchura del producto70.85 cm26.24 cmPeso del producto Conformidad(es)28.86 kg Con marca CETUVCertificación(es)IEC/EN 62040-1IEC/EN 62040-2CEEAC60 HzOnda sinusoidal48 kW0,8Torre3NoConexiones de cables/fijas110 V240 V50 HzEaton Intelligent Power Manager Eaton Intelligent Power ProtectorSin batería921EU declaration of conformity Eaton 9E UPSFrecuencia secundaria (máx.)Forma de onda de salidaNúmero máximo de bateríasPotencia en vatiosFactor de potencia de salidaDiseño externoSalida de distorsión de tensión (carga lineal) (máx.)Incluye tarjeta de redConexión de entradaTensión de entrada (mín.)Tensión de salida (máx.)Frecuencia secundaria (mín.)Compatibilidad de softwareSustitución de la bateríaRendimientoNúmero de salidas cableadasCaracterísticas especialesCompliance information Topología de dobleconversiónEl Eaton 9SX monitoriza de manera constante lascondiciones energéticas yregula la tensión y lafrecuenciaBypass interno que permitela continuidad en caso defallo del SAIPantalla LCD para estado y mediciones en tiempo real Compatible con entornosvirtuales (VMware, Hyper-V,Citrix Xen, Redhat)Tipo de construcciónModelo independienteTensión de salida (mín.)220 VColorNegroCapacidad de batería ampliadaSíRango de tensión de salida220/230/240 V +/- 2%TopologíaConversión doble/OnlineClasificación BTUOnline: 2456Eficiencia (modo Eco)96Tiempo de autonomía con carga media 0 minTensión nominal de entrada230 V predeterminado (220/230/240V)Factor de potencia de entrada Superior a 0,99Rango de frecuencia de entrada45-66HzBypass internoSíTensión de entrada (máx.)276 VTipo de tensiónCAFase (salida)1Gestión de la bateríaPrueba automática de labateríaProtección contra descarga profunda (Deep discharge protection)Función de apagado automáticoSíCapacidad nominal VA10 kVAContacto de maniobra sin potencialSíContenido del paqueteUPSCable USBCable serieManual de usuarioNivel de ruidoMenos de 55 dB a 1 metroTipo de alimentación1Gráfico de tiempo de ejecuciónVer gráfico de tiempo de autonomíaInterfaz de usuarioPantalla LCDCantidad de bateríasTensión230/400 VAlimentación intercambiable en caliente NoMargen de temperaturaDe 0 °C a 40 °C (de 32 °F a 104 °F)Interfaz EthernetNoComunicacionesPuerto USB (compatible conHID)Puerto serie RS-232Bloque de mini terminalespara el paro de emergenciaPérdida de comunicaciónHumedad relativa0-95% sin condensaciónSet de montaje en rackNoFrecuencia de salida50/60 HzTiempo de autonomía a carga completa0 minTipo de interfazOtrosFrecuencia principal - Mín.45 HzTipoUPSTensión nominal de salida230 V predeterminado (220/230/240V)Ranuras de expansiónRanura para una tarjeta de comunicación opcionalRango de tensión de entrada176-276 V (110-276 V con pérdida de potencia)Frecuencia nominal50/60 HzFrecuencia principal - Máx.66 HzAltitud3.000 mEaton Corporation plc Eaton House30 Pembroke Road Dublin 4, Ireland © 2023 Eaton. All Rights Reserved. Eaton is a registered trademark.All other trademarks areproperty of their respectiveowners./socialmedia。

欧美尔系列xPole UK - EAM RCCB EAM402HEOV 电流保护设备说明说明书

欧美尔系列xPole UK - EAM RCCB EAM402HEOV 电流保护设备说明说明书

Eaton EAM402HEOVEaton Moeller series xPole UK - EAM RCCB. Residual current circuit-breaker, 40 A, 2-pole, 30mA, Type A, HEOVGeneral specificationsEaton Moeller series xPole UK - EAM RCCBEAM402HEOV EAM402HEOV501958614144680 mm 71 mm 35 mm 0.22 kg RoHS conformIEC/EN 61008Product NameCatalog Number Model Code EANProduct Length/Depth Product Height Product Width Product Weight Compliances CertificationsSwitchgear for residential and commercial applications Two-poleNon-delayed40 A10 kA30 mAAC current sensitivePartly surge-proof 250 A 230 V AC230 V440 V4 kV0.03 A0.03 A50 Hz63 A (max. admissible back-up fuse) A500 A25 A gG/gL10 kA0.25 kA196 V AC - 264 V AC24000 operationsApplicationNumber of polesTripping timeAmperage RatingRated short-circuit strength Fault current rating Sensitivity typeImpulse withstand current Type Voltage ratingRated operational voltage (Ue) - maxRated insulation voltage (Ui)Rated impulse withstand voltage (Uimp) Rated fault current - minRated fault current - maxFrequency ratingShort-circuit ratingLeakage current typeRated residual making and breaking capacity Admissible back-up fuse overload - max Rated short-time withstand current (Icw) Surge current capacityTest circuit rangePollution degreeLifespan, electricalEAMResidual current circuit breakersType A45 mm235 mm (2 SU)70.5 mmIEC/EN 60715 top-hat railDIN railIP40, IP54 (with moisture-proof enclosure)IP20Box clamp1.5 mm² - 35 mm²1.5 mm²35 mm²1.5 mm²16 mm²Finger and hand touch safe, DGUV VS3, EN 50274 0.8 mm - 2 mm20000 operations-35 °C60 °C 40 A0 W5.8 W0 W0 W-25 °C60 °CMeets the product standard's requirements.Meets the product standard's requirements.Meets the product standard's requirements.Meets the product standard's requirements.Meets the product standard's requirements.Does not apply, since the entire switchgear needs to be evaluated.Does not apply, since the entire switchgear needs to be evaluated.Meets the product standard's requirements.Does not apply, since the entire switchgear needs to beFrameWidth in number of modular spacingsBuilt-in width (number of units)Built-in depthMounting MethodDegree of protectionTerminals (top and bottom)Terminal capacity (solid wire)Connectable conductor cross section (solid-core) - min Connectable conductor cross section (solid-core) - max Connectable conductor cross section (multi-wired) - min Connectable conductor cross section (multi-wired) - max Terminal protectionBusbar material thicknessLifespan, mechanicalPermitted storage and transport temperature - min Permitted storage and transport temperature - max Climatic proofing Rated operational current for specified heat dissipation (In) Heat dissipation per pole, current-dependentEquipment heat dissipation, current-dependentStatic heat dissipation, non-current-dependentHeat dissipation capacityAmbient operating temperature - minAmbient operating temperature - max10.2.2 Corrosion resistance10.2.3.1 Verification of thermal stability of enclosures10.2.3.2 Verification of resistance of insulating materials to normal heat10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects10.2.4 Resistance to ultra-violet (UV) radiation10.2.5 Lifting10.2.6 Mechanical impact10.2.7 Inscriptions10.3 Degree of protection of assemblies25-55 °C / 90-95% relative humidity according to IEC 60068-2evaluated.Meets the product standard's requirements.Does not apply, since the entire switchgear needs to be evaluated.Does not apply, since the entire switchgear needs to be evaluated.Is the panel builder's responsibility.Is the panel builder's responsibility.Is the panel builder's responsibility.Is the panel builder's responsibility.Is the panel builder's responsibility.The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.Is the panel builder's responsibility. The specifications for the switchgear must be observed.Is the panel builder's responsibility. The specifications for the switchgear must be observed.The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.Residual current circuit breaker Additional equipment possible eaton-rcd-application-guide-br019003en-en-us.pdf eaton-protective-devices-catalog-ca20190603-en-us.pdf10.4 Clearances and creepage distances 10.5 Protection against electric shock10.6 Incorporation of switching devices and components 10.7 Internal electrical circuits and connections 10.8 Connections for external conductors 10.9.2 Power-frequency electric strength 10.9.3 Impulse withstand voltage 10.9.4 Testing of enclosures made of insulating material 10.10 Temperature rise10.11 Short-circuit rating10.12 Electromagnetic compatibility10.13 Mechanical functionFeaturesFitted with:Application notesCataloguesEaton Corporation plc Eaton House30 Pembroke Road Dublin 4, Ireland © 2023 Eaton. All rights reserved. Eaton is a registered trademark.All other trademarks areproperty of their respectiveowners./socialmediaInterlocking deviceMaximum operating temperature is 60 °C: Starting at 40 °C, the max. permissible continuous current decreases by 3% for every 1 °CEAMResidual current circuit breakersType A eaton-xpole-accessories-ca019015en-en-us.pdf03_EAM_181019DA-DC-03_EAM_020616DA-DC-03_EAMSpecial featuresUsed withCertification reports。

海康威视GPT-12000系列电源安全分析仪说明书

海康威视GPT-12000系列电源安全分析仪说明书

CONTINUITY TEST
Output-Current Ohmmeter Measurement Range
Ohmmeter Measurement Resolution Ohmmeter Measurement Accuracy Window Comparator Method TIMER (Test Time)
Function Model
Output Capacity
AC
DC
IR
GB Continuity Rear Output
GPT-12001
200VA
GPT-12002
200VA
GPT-12003
200VA
GPT-12004
200VA
7” LCD
SPECIFICATIONS
AC WITHSTANDING Output-Voltage Range Output-Voltage Resolution Output-Voltage Accuracy Maximum Rated Load Maximum Rated Current Output-Voltage Waveform Output-Voltage Frequency Voltage Regulation Voltmeter Accuracy Current Measurement Range Current Best Resolution Current Measurement Accuracy Window Comparator Method ARC Detect RAMP UP (Rise Time) RAMP DOWN (Fall Time) TIMER (Test Time) WAIT TIME GND DC WITHSTANDING Output-Voltage Range Output-Voltage Resolution Output-Voltage Accuracy Maximum Rated Load Maximum Rated Current Voltage Regulation Voltmeter Accuracy Current Measurement Range Current Best Resolution Current Measurement Accuracy Window Comparator Method ARC Detect RAMP UP (Rise Time) RAMP DOWN (Fall Time) TIMER (Test Time) WAIT TIME GND

科华-EXPLORER 510 迷你卫星伴侣产品介绍说明书

科华-EXPLORER 510 迷你卫星伴侣产品介绍说明书

A rugged BGAN fit for purposeThe all new EXPLORER 510 is the smallest ever EXPLORER BGAN and the ideal combination of performance and portability.The durable magnesium casing and a dust and water resistant design makes the EXPLORER 510 the perfect choice when working off the beaten track, but still dependant on a reliable connection.Satellite connectivity made simpleEXPLORER 510 is easy to set-up and to operate. The user interface is intuitive and can be accessed from your PC or any kind of smart device.With the EXPLORER Connect App you can use your smart device to make calls or easily access the internet even in areas with no terrestrial or cellular coverage. The EXPLORER Connect App with a SIP softphone is available on Android and IOS.EXPLORER 510Ultra-Portable Satellite Companion/satcomInterfacesWLAN Access Point Standard:IEEE 802.11 b/g/n 1 x USB host interface Version: 2.0 (host)Charging:Up to 1A1 x BGAN SIM-Card slotEnvironmental conditionsTemperatureOperational (ambient): -25°C to +55°C / -13°F to +131°F Storage:-25°C to +80°C / -13°F to +176°FBattery storage temperature 1 month: -20°C to +60°C / -4°F to +140°F 3 months: -20°C to +45°C / -4°F to +113°F 1 year: -20°C to +25°C / -4°F to +77°F Relative humidity: 95% non-condensing at +40°C/+104°FRobustness: 0.5 m/1.64 ft drop on concrete(operational, 95% survival)Water and dust:IP-66 CompiantPowerDC input range: 10.5-32VDCPower consumption Standby / transmit: 2.8W / 19W (typical)During charging: 20W (max.)Connector type2.5mm EIAJ RC-5320-IVAC/DC power supply Input: 100-240VAC, 47-63Hz, 64W Output: 19VDC Built-in Battery: Lithium ion (rechargeable)Stand-by time: 24h, 0°C to 55°C / +32°F to +131°Standard call:Minimum 3h (TBC)Receive time, max.: 4h40m @ 128kbps Transmit time, max.: 2h25m @ 128kbps Recharge time:Less than 3 hoursCharge temperature:0°C to 45°C / +32°F to +113°SpecificationsDimensions Total H / W / D: 202 / 202 / 51.8 mm7.8 / 7.8 / 1.6 inches Weight (incl. battery): 1.4kg / 3.1lbs Data capabilities Standard IP: Up to 464 kbps Streaming IP: 32, 64, 128 kbps Voice capabilities Standard voice: 4 kbpsPremium voice: 3.1 kHz audio, 64 kbps Inmarsat frequencies: 1518.0 - 1525.0 MHz (Rx) (EMEA) 1525.0 - 1559.0 MHz (Rx) 1626.5 - 1660.5 MHz (Tx)1668.0 - 1675.0 MHz (Tx) (EMEA)EIRP:15.1 dBW ±1dBUser interface: Two LED (WLAN, Status), 1 Power Button USB Host, Cobham web interface Languages: ENG, FR, DE, ES, RU, JP and CN Approvals: CE, FCC, IC, C-TICKInmarsat Class 2 Type ApprovalOther featuresEXPLORER Connect App for IOS and Android:Includes a SIP Softphone, Terminal Access to control your BGAN and Pointing Assistance.EXPLORER Cellular Modem for USB:With the EXPLORER LTE Modem you can connect local cellular networks and use the EXPLORER 510 as wireless router for all your devices.Package• EXPLORER 510 terminal• Built-in Rechargeable Lithium Ion Battery • EXPLORER Softbag• USB to Ethernet Converter Cable • 100-240VAC Power Supply • Multi-Languge Quick Start Quide• Multi-language webserver and embedded manual (ENG, FR, DE, ES, RU, JP and CN)Accessories• Polemount• EXPLORER Softbag (included in the package)• 100-240VAC power supply • Car Charger cable• EXPLORER Cellular USB ModemProduct number403711A-00500EXPLORER 510 TerminalPortable performanceSmaller than a standard laptop and weighing less than 1.4 kg, this satellite terminal is easy to carry along when travelling the world. It supports your need for performance and provides simultaneous high quality voice and broadband access at speeds up to 464 kbps. Connect the optional EXPLORER Cellular Modem to the USB port and turn your device into a true communication SmartHub. Use local cellular netwhen available and BGAN if no other option.71-142699-B 02 02.16 L M B U。

爱尔顿空冷备用生电器系统9千瓦和11千瓦说明书

爱尔顿空冷备用生电器系统9千瓦和11千瓦说明书

1Air-cooled standby generator systems 9 kW and 11 kWSystem overview• Complete backup power system featuring afull line of Eaton automatic transfer switchesand generators• Exclusive national Eaton Certified ContractorNetwork (ECCN) contractors for installation,maintenance, and service• Local sales expertise and round-the-clocktelephone pre-/post-sales technical supportEGSX200NSEAEGENA11T able 1. Generator featuresFeatures BenefitsEngine• Overhead valve industrial enginedesign (OHVI)• ”Spiny-lok” cast iron cylinder walls• Electronic ignition/spark advance• Full pressure lubrication system• Low oil pressure shutdown system• High temperature shutdown • Maximizes engine “breathing” for increased fuel efficiency. Plateau-honed cylinder walls and plasma moly rings help engine run cooler, reducing oil consumption. Because heat is the primary cause of engine wear, the OHVI has a significantly longer life than competitive engines • Rigid construction and added durability provide long engine life• Assured smooth, quick start every time• Pressurized lubrication to all vital bearings means better performance, less maintenance, and significantly longer engine life. Now featuring a 2-year/200-hour oil change interval• Superior shutdown protection prevents catastrophic engine damage from low oil• Prevents damage due to overheatingGenerator• Revolving field• Skewed stator (only)• Displaced phase excitation• Automatic voltage regulation• UL T 2200 Listed • Allows for smaller, lightweight unit that operates 25% more efficiently than a revolving armature generator• Produces a smooth output waveform for electronic equipment compatibility• Maximizes motor starting capability• Regulates the output voltage to ±2%, which prevents damaging voltage spikes• Compliant with all safety regulationsNew controller and controls• Auto/Manual/Off illuminated buttons• Utility voltage sensing• Utility interrupt delay• Engine warm up• Engine cool down• Main line circuit breaker• Electronic governor• Smart battery charger• Two-Line LCD multilingual display• Sealed, raised buttons• Generator voltage sensing• Programmable exercise • Selects the operating mode for easy, at-a-glance status indication in any condition• Weather-resistant interface allows smooth programming and operations for the user• Constantly monitors utility voltage, set points 60% dropout, and 80% pickup of standard voltage • Ensures engine is ready to assume the load, set point approximately 5 seconds• Allows engine to cool prior to shutdown, set point approximately 1 minute• Protects generator from overload• Maintains constant 60 Hz frequency• Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM-style batteries• Provides homeowners easily visible logs of history, maintenance, and events up to 50 occurrences • Smooth, weather-resistant user interface for programming and operations• Constantly monitors generator voltage to ensure the cleanest power delivered to the home• Operates engine to prevent oil seal drying and damage between power outages by running the generator for 12 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the ownerUnit• SAE weather-protective enclosure• Enclosed critical grade muffler• Small, compact, attractive • Sound attenuated enclosures ensure quiet operation and protection against Mother Nature, withstanding winds up to 150 mph. Hinged key locking roof panel for security. Lift-out front for easy access to all routine maintenance items. Electrostatically applied textured epoxy paint for added durability• Quiet, critical grade muffler is mounted inside the unit to prevent injuries. Complies with local dB noise levels• Makes for an easy, eye-appealing installationInstallation system• 1-foot flexible fuel line connector• Direct-to-dirt composite mounting pad• Integral sediment trap • Easy installation• Complex lattice design prevents settling or sinking of the generator system• Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine lifeWarranty a• 5-year limited warranty:• Years 1 and 2—limited comprehensive coverage on mileage, labor, and parts (warranty certification required)• Year 3—limited comprehensive coverage on parts only• Years 4 and 5—limited comprehensive coverage on engine (short block) and alternator (rotor and stator) parts only a For warranty details, refer to the “Eaton Air-Cooled Automatic Standby Generators” warranty statement.T able 2. Compatible automatic transfer switches aFeatures BenefitsEGSU series featuringuniversal active loadmanagement• Truly active load management system• RTC-100 controller with built-in intelligence• Universal compatibility with any generator brand (single-phase, 240 V)• No programming necessary• Whole house surge included (catalog number: CHSPT2ULTRA)• 50 or 60 Hz• Current sensors (CTs) included• Built-in 7-, 14-, and 28-day plant exerciser• Load and no-load transfer• Meets NEC T Article 702.5 for optional standby backup power systems• UL 1008 Listed• Actively balances electrical loads in the household, adjusting tohomeowner’s lifestyle• Complete home surge protector included to protect home electronicsand appliances against surge events• Complete power monitoring for greater accuracy and load management:voltage, current, and frequency• Power monitoring system allows 100% use of power output ratingin the generator• Contractor-friendly installation, requires fewer connections tothe generator• Environmentally friendly: allows downsizing of generator resultingin decrease of greenhouse gas (GHG) emissions, and reduces gasconsumption by 15% or moreEGSX series featuringload shedding• Two sets of contacts for load shedding• Simplified, non-redundant relay-interface system• Terminal block termination; connections labeled to match generatorconnections• Three-point keyhole mounting system for quick, level installation• Optimal wire bending space• Commercial grade main breaker included• UL 1008 compliant• Meets NEC Article 702.5 for optional standby backup power systems• Easy, intuitive installation for labor savings• Compatible with Eaton generators and most standby generator brands• Smallest footprint in the industry (400 A model)Warranty b• 1-year limited warranty from the date of installation or 18 months from the date of shipment, whichever occurs first• Extended and special warranties available:• 24 months—2% of contract price• 30 months—3% of contract price• 36 months—4% of contract pricea For selection information, visit our online green ATS interactive demo at .b For warranty details, refer to Eaton Selling Policy 25-000.T able 3. Automatic transfer switch specificationsAmperes VoltagesNumberof polesServiceentranceNumberof circuitsincluded a FrequencyEnclosuretypeContactorwire sizeranges(s)Numberof cablesper phaseWithstandcurrent(rms) at240 VacMost commongeneratorsizes bCatalognumberEGSU series50120/2402—2450/60NEMA 3R#14–#2/0110,0009, 11, 16 kW EGSU100L24RACA 50120/2402——50/60NEMA 3R#14–#2/0110,0009, 11, 16 kW EGSU100ACA 100120/2402Y—50/60NEMA 3R#14–#2/0110,0009, 11, 16 kW ESGU100NSEACA 100120/2402Y—50/60NEMA 3R#4–300 kcmil125,0009, 11, 16 kW EGSU150NSEACA 200120/2402——50/60NEMA 3R#4–300 kcmil125,00016, 20, 22 kW EGSU200ACA 200120/2402Y—50/60NEMA 3R#4–300 kcmil125,00016, 20, 22 kW EGSU200NSEACA 200120/2402Y—50/60NEMA 3R750 kcmil–2 /300 kcmil–1/01/235,000>22 kW EGSU400NSEACA EGSX series50120/2402Y1250/60NEMA 1#14–#6150009, 11 kW EGSX50L12 50120/2402—1250/60NEMA 3R#14–#6150009, 11 kW EGSX50L12R 100120/2402——50/60NEMA 3R#14–#2/0110,0009, 11, 16 kW EGSX100A 100120/2402Y—50/60NEMA 3R#14–#2/0110,0009, 11, 16 kW EGSX100NSEA 100120/2402—2450/60NEMA 3R#14–#2/0125,0009, 11, 16 kW EGSX100L24RA 150120/2402Y—50/60NEMA 3R#4–300 kcmil125,00016, 20, 22 kW EGSX150NSEA 200120/2402——50/60NEMA 3R#4–300 kcmil125,00016, 20, 22 kW EGSX200A 200120/2402Y—50/60NEMA 3R#4–300 kcmil125,00016, 20, 22 kW EGSX200NSEA 400120/2402Y—50/60NEMA 3R750 kcmil–2 /300 kcmil–1/01/235,000>22 kW EGSX400NSEAa Uses CH type circuit breakers.b For reference only. Generator size must be determined by actual load calculations.T able 4. Generator specificationsCatalog numberEGENA9EGENA11 GeneratorRated maximum continuous power capacity (LP)/(NG)9000/8000 watts a11,000/10,000 watts a Enclosure Aluminum AluminumRated voltage240240Rated maximum continuous load current 240 V b37.5/33.3 NG45.8/41.7 NGTotal harmonic distortion Less than 5%Less than 5%Main line circuit breaker40 A50 APhase Single SingleNumber of rotor poles22Rated AC frequency60 Hz60 HzPower factor 1.0 1.0Battery requirement (not included)Group 26R, 12 V and525 cold-cranking amperes minimumor Group 35AGM 650 cold-crankingamperes minimum Group 26R, 12 V and525 cold-cranking amperes minimum or Group 35AGM 650 cold-cranking amperes minimumUnit weight lb (kg)340/154348 (158)Dimensions in inches (mm) L x W x H 48.00 x 25.00 x 29.00(1219.2 x 635.0 x 736.6)48.00 x 25.00 x 29.00(1219.2 x 635.0 x 736.6)Sound output in dBA at 23 ft with generatoroperating at normal load6663EngineType of engine OHVI OHVI V-TWINNumber of cylinders12Displacement410 cc530 ccCylinder block Aluminum with cast iron sleeve Aluminum with cast iron sleeve Valve arrangement Overhead valve Overhead valveIgnition system Solid-state with magneto Solid-state with magneto Governor system Electronic Electronic Compression ratio9.0:19.5:1Starter12 Vdc12 VdcOil capacity including filter Approximately 1.1 qt/1.0 L Approximately 1.7 qt/1.6 L Operating RPM3,6003,600Fuel consumption cNatural gas ft³/hr (m³/hr): 1/2 loadFull load 90 (2.55)120 (3.4)107 (3.03)159 (4.50)Liquid propane ft³/hr (gal/hr) (liters/hr): 1/2 loadFull load 31.6 (0.87) (3.29)50 (1.37) (5.2)44.4 (1.22) (4.62)71.6 (1.97) (7.45)a Suitable for “optional” standby backup power only, as indicated by NEC Article 702. Not suitable for legally required “emergency” life safety applications as required by NEC Article 700 and NFPA 110/99. All ratings in accordance with BS5514, ISO3046, and DIN6271. Maximum wattage and current are subject to and limited by such factors as fuel BTU content, ambient temperature, altitude, engine power, and condition. Maximum power decreases about 3.5% for each 1000 feet above sea level, and also will decrease about 1% for each 12 °C (10 °F) above 15.5 °C (60 °F).b LP = Liquid propaneNG = Natural gasc Gas pipe sizing is critical for the proper operation of the generator. Fuel pipe must be sized for full load. Required fuel pressure to generator fuel inlet at all load ranges—3.5 to 7 inches water column(7 to 13 mm mercury) for natural gas, 10 to 12 inches water column (19 to 22 mm mercury) for LP gas. For BTU content, multiply ft3/hr x 2500 (LP) or ft3/hr x 1000 (NG). For Megajoule content,multiply m3/hr x 93.15 (LP) or m3/hr x 37.26 (NG).T able 5. Generator controlsFeatures DescriptionTwo-line plain text multilingual LCD display Simple user interface for ease of operationMode buttonsAutoManualOffAutomatic start on utility failure. 7-day exerciser (7-, 14-, and 28-day exerciser when coupled with EGSU ATS)Start with starter control, unit stays on. If utility fails, transfer to load takes placeStops unit. Power is removed. Control and charger still operateReady to run/maintenance messages StandardEngine run hours indication StandardProgrammable start delay between 2 and 1500 seconds Standard (programmable by dealer only)Utility voltage loss/return to utility adjustable From 140 V to 171 V/190 V to 216 VFuture set capable exerciser/exercise set error warning StandardRun/alarm/maintenance logs50 events eachEngine start sequence Cyclic cranking 16 seconds on, 7 rest (90 seconds maximum duration)Starter lockout Starter cannot re-engage unit 5 seconds after engine has stoppedSmart battery charger StandardCharger fault/missing AC warning StandardLow battery/battery problem protection and battery condition indication StandardAutomatic voltage regulation with overvoltage and undervoltage protection StandardUnderfrequency/overload/stepper overcurrent protection StandardSafety fused/fuse problem protection StandardAutomatic low oil pressure/high oil temperature shutdown StandardOvercrank/overspeed at 72 Hz/RPM sense loss shutdown StandardHigh engine temperature shutdown StandardInternal fault/incorrect wiring protection StandardCommon external fault capacity StandardField-upgradable firmware StandardT able 6. Compatible accessories and replacement parts—EGENA generatorsDescription Benefits/features Catalog number Maintenance and general accessoriesBattery pad warmer The pad warmer rests under the battery. Recommended for use if the temperature regularly falls below 0 7F.(Not necessary for use with AGM-style batteries).7101CHOil warmer Oil warmer slips directly over the oil filter. Recommended for use if the temperature regularly falls below 0 7F.7102CH Breather warmer The breather warmer is for use in extreme cold weather applications. For use with standard controllersonly in climates where heavy icing occurs.7103CHMaintenance kit for 9 kW generators Includes all hardware and material necessary to perform scheduled preventive maintenance. Compatiblewith model EGENX9 only.6482CHMaintenance kit for 11 kW generators Includes all hardware and material necessary to perform scheduled preventive maintenance. Compatiblewith model EGENX11 only.6483CH Bisque color paint kit Ideal for touch-up paint/maintenance to generator enclosure against scratches and future corrosion.EGENPAINT Generator fascia Enhances aesthetics. Installs in seconds (standard with EGENX20A and EGENX22A models).EGENFASCIA Air-cooled transportation cart User-friendly assembly, attaches to lifting holes. Smart design allows only one person to lift the unitoff of wooden pallet and position it for final installation.EGENCART MonitoringMobile wireless remote monitor Most advanced generator status monitoring system. Allows connectivity and settings programmingvia smart devices (laptops, smartphone, pad, etc.). Sends automated emails and/or text messagesto multiple users. Requires cell phone signal and subscription.EGENMOBILEIn-house wireless monitor In-house generator status basic monitoring system. No computer connectivity required. 600 ft radiusof wireless coverage.EGENINHOME T able 7. Replacement parts—EGSX ATSComponent Catalog number50 A100 A150 A200 A400 AContactor99-5643-899-5638-1299-5702-1599-5702-1599-5702-16 Wire harness a99-5643-799-5638-1399-5702-1799-5702-1799-5702-18 Neutral bar99-5643-699-5638-799-5702-699-5702-699-5702-13 Ground lugs99-5643-499-5638-599-5702-499-5702-499-5702-4 Service entrance breaker—99-5638-4CSR2150CSR2200KD2400 Contactor lugs99-5643-599-5638-699-5702-599-5702-599-5702-12 a Includes relay and mounting base.T able 8. Replacement parts—EGSU ATSComponent Catalog number100 A150 A200 A400 AController RTC100RTC100RTC100RTC100 Contactor99-5638-1299-5702-1599-5702-1599-5702-16 Wire harness99-5638-1499-5702-799-5702-799-5702-19 Service entrance breaker99-5638-4CSR2150CSR2200KD2400 c Ground bar99-5638-5 a99-5702-49-5702-499-5702-4 Contactor lugs99-5638-699-5702-599-5702-599-5702-12 Neutral bar99-5638-7 b99-5702-699-5702-699-5702-13 Current sensors CS200CS200CS200CS400 Whole house surge protector CHSPT2ULTRA CHSPT2ULTRA CHSPT2ULTRA CHSPT2ULTRAa For EGSU100L24RACA, order ground bar catalog number 99-5638-15.b For EGSU100L24RACA, order neutral bar catalog number 99-5638-17.c For breaker lugs, order catalog number 2TA401K.Figure 1. Air-cooled generator 9 kW and 11 kW—dimensions in inches (mm) Dimensions shown are approximate. Design and specificationssubject to change without notice. For additional information, visitour website at , call our technicalresource center at (877) ETN-CARE (386-2273), or contact yourlocal Eaton authorized distributor.Eaton1000 Eaton Boulevard Cleveland, OH 44122 United States © 2016 EatonAll Rights ReservedPrinted in USAPublication No. TD00405002E / Z19034 December 2016Eaton is a registered trademark.All other trademarks are propertyof their respective owners.Air-cooled standby generator systems 9 kW and 11 kWTechnical Data TD00405002EEffective December 2016Figure 2. Plan view of an EGSX150NSEA/EGSX200NSEA—dimensions in inches (mm)T able 9. Automatic transfer switches approximate dimensions in inches (mm)Amperes Width Height Depth Weight in lb (kg) 5014.25 (362.0)21.00 (533.4) 4.00 (101.6)23 (10.43) 10014.46 (367.3)16.87 (428.5) 5.32 (135.1)25 (11.33)100 with loadcenter14.46 (367.3)29.33 (745.0) 5.32 (135.1)38 (17.23) 15014.46 (367.3)29.33 (745.0) 5.32 (135.1)45 (20.41)200 a14.46 (367.3)29.33 (745.0) 5.32 (135.1)45 (20.41) 40023.14 (587.8)37.56 (954.0)10.00 (254.0)130 (58.96)a Height for 200 A non-SE is 25.08 (637.0).。

封闭型不泄露维保电池6MF9A 12V9Ah说明书

封闭型不泄露维保电池6MF9A 12V9Ah说明书

Effective Date: 2020/01/09 DG2000293E> Product IdentifierProduct Name Sealed, non spilable maintenance free battery 6MF9A 12V9Ah Synonyms-> Relevant Identified Uses of the Substance or Mixture and Uses Advised AgainstRelevant Identified UsesPlease consult manufacturer. Uses Advised AgainstPlease consult manufacturer.> Details of the Supplier of the Safety Data SheetApplicant Name Sichuan Liyang Industry Co., LtdApplication Address Yanhuasi Industry Park, Anju District, Suining City, Sichuan P .R.China Applicant Post Code 401320Applicant Telephone +86-825-62597757Applicant Fax +86-825-62571653 Applicant E-mail ******************Supplier Name Sichuan Liyang Industry Co., LtdSupplier Address Yanhuasi Industry Park, Anju District, Suining City, Sichuan P .R.China Supplier Post Code 401320Supplier Telephone +86-825-62597757 Supplier Fax +86-825-62571653 Supplier E-mail******************>Emergency Phone NumberEmergency Phone Number+86-825-62597757Hazard class and label elements of the product according to GHS (the seventh revised edition):> GHS Hazard ClassSkinCorrosion/Irritation Category 1 Eye Damage/Irritation Category 1 Reproductive ToxicityCategory 1Reproductive Toxicity Additional>GHS Label ElementsPictogramSignal Word Danger> Hazard StatementsH314 Causes severe skin burns and eye damageH318 Causes serious eye damageH360 May damage fertility or the unborn childH362 May cause harm to breast-fed children> Precautionary StatementsPreventionP201 Obtain special instructions before use.P202 Do not handle until all safety precautions have been read and understood.P260 Do not breathe dust/fume/gas/mist/vapours/spray.P263 Avoid contact during pregnancy and while nursing.P264 Wash contact area thoroughly after handling.P270 Do not eat, drink or smoke when using this product.P280 Wear protective gloves/protective clothing/eye protection/face protection. ResponseP310 Immediately call a POISON CENTER/doctor.P321 Specific treatment (see measures on this label).P363 Wash contaminated clothing before reuse.P304+P340 IF INHALED: Remove person to fresh air and keep comfortable for breathing. P308+P313 IF exposed or concerned: Get medical advice/ attention.P301+P330+P331 IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.P303+P361+P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skinwith water/shower.P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contactlenses, if present and easy to do. Continue rinsing.StorageP405 Store locked up.DisposalP501 Dispose of contents/container in accordance with local/regional/national/international regulations.Component Concentration (weightpercent, %) CAS No. EC No.Lead 64.91 7439-92-1 231-100-4 Glass, oxide, chemicals 5.32 65997-17-3 266-046-0Sulphuric acid 10.08 7664-93-9 231-639-5Water11.517732-18-5231-791-2> Description of First Aid MeasuresGeneral Advice Immediate medical attention is required. Show this safety data sheet (SDS) to the doctor in attendance.Eye Contact Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician if feel uncomfortable.Skin Contact Take off contaminated clothing and shoes immediately. Wash off with plenty of water for at least 15 minutes and consult a physician if feel uncomfortable. Ingestion Do not induce vomiting. Never give anything by mouth to an unconscious person. Call a physician or Poison Control Center immediately.Inhalation Move victim into fresh air. If breathing is difficult, give oxygen. Do not usemouth to mouth resuscitation if victim ingested or inhaled the substance. If not breathing, give artificial respiration and consult a physician immediately. Protecting of First-aidersEnsure that medical personnel are aware of the substance involved. Take precautions to protect themselves and prevent spread of contamination.> Most Important Symptoms and Effects, both Acute and Delayed1Substance accumulation, in the human body, may occur and may cause some concern following repeated or long-term occupational exposure.> Indication of Any Immediate Medical Attention and Special Treatment Needed1 Treat symptomatically.2 Symptoms may be delayed.> Extinguishing MediaSuitable Extinguishing MediaDry chemical, carbon dioxide, water spray,alcohol-resistant foam. UnsuitableExtinguishing MediaDo not use a solid water stream as it may scatter or spread fire.> Specific Hazards Arising from the Substance or Mixture1 Containers may explode when heated.2 Fire exposed containers may vent contents through pressure relief valves.3 May expansion or decompose explosively when heated or involved in fire.> Advice for Firefighters1As in any fire, wear self-contained breathing apparatus (MSHA/NIOSH approved or equivalent)and full protective gear.2 Fight fire from a safe distance, with adequate cover.3 Prevent fire extinguishing water from contaminating surface water or the ground water system.> Personal Precautions, Protective Equipment and Emergency Procedures1 Ensure adequate ventilation. Remove all sources of ignition.2 Evacuate personnel to safe areas. Keep people away from and upwind of spill/leak.3 Use personal protective equipment. Avoid breathing vapours, mist, gas or dust.> Environmental Precautions1 Prevent further leakage or spillage if safe to do so.2 Discharge into the environment must be avoided.> Methods and Materials for Containment and Cleaning Up1Absorb spilled material in dry sand or inert absorbent. In case of large amount of spillage, contain a spill by bunding.2Adhered or collected material should be promptly disposed of, in accordance with appropriate laws and regulations.3 Remove all sources of ignition. Use spark-proof tools and explosion-proof equipment. > Precautions for Handling1 Handling is performed in a well ventilated place.2 Wear suitable protective equipment.3 Avoid contact with skin and eyes.4 Keep away from heat/sparks/open flames/ hot surfaces.5 Take precautionary measures against static discharges.> Precautions for Storage1 Keep containers tightly closed.2 Keep containers in a dry, cool and well-ventilated place.3 Keep away from heat/sparks/open flames/ hot surfaces.4 Store away from incompatible materials and foodstuff containers.> Control ParametersNo information available Monitoring Methods1EN 14042 Workplace atmospheres. Guide for the application and use of procedures for the assessment of exposure to chemical and biological agents.2GBZ/T 160 Determination of toxic substances in workplace air(Series effective standard)and GBZ/T 300 Determination of toxic substances in workplace air(Series standard).> Engineering Controls1 Ensure adequate ventilation, especially in confined areas.2 Ensure that eyewash stations and safety showers are close to the workstation location.3 Use explosion-proof electrical/ventilating/lighting/equipment.4 Set up emergency exit and necessary risk-elimination area.> Personal Protection EquipmentEye Protection Tightly fitting safety goggles (approved by EN 166(EU) or NIOSH (US).Hand Protection Wear protective gloves (such as butyl rubber ), passing the tests according to EN 374(EU),US F739 or AS/NZS 2161.1 standard.Respiratory protection If exposure limits are exceeded or if irritation or other symptoms areexperienced, use a full-face respirator with multi-purpose combination (US) or type AXBEK (EN 14387) respirator cartridges.Skin and BodyProtectionWear fire/flame resistant/retardant clothing and antistatic boots.Appearance: Black Plastics cement shell BatteryOdor: No information availableOdor Threshold: No information available pH: No information availableMelting Point/Freezing Point (℃): No information available Initial Boiling Point and Boiling Range (℃): No information available Flash Point (℃)( Closed Cup): Not applicableEvaporation Rate: Not applicableFlammability: No information available Upper/lower explosive limits[%(v/v)]: Upper limit :No information available ;Lower limit :No informationavailableVapor Pressure (KPa): Not applicable Relative Vapour Density(Air =1): Not applicable Relative Density(Water=1): No informationavailableSolubility: No information availablen-Octanol/Water Partition Coefficient: No information available Auto-Ignition Temperature(℃): No information available Decomposition Temperature (℃): No informationavailableKinematic Viscosity (mm 2/s): Not applicableParticle characteristics: No information availableReactivityContact with incompatible substances can cause decomposition or other chemical reactions.Chemical Stability Stable under proper operation and storage conditions.Possibility ofHazardous ReactionsReacts severely with halogens, interhalogens or other strong oxidants, or causes a fire. In contact with active metals (alkali metals, Na, Ca etc.) causes areaction and release hydrogen.Conditions to AvoidIncompatible materials, heat, flame and spark.Incompatible Materials Halogen, interhalogen, strong oxidant, water and acids. Alkali, sodium, calcium,and other active metal, halogen, metal oxide, nonmetal oxide, acyl halide and metal phosphide.Hazardous Decomposition productsUnder normal conditions of storage and use, hazardous decomposition products should not be produced.> Acute Toxicity> Skin Corrosion/IrritationCauses severe skin burns and eye damage(Category 1)> Serious Eye Damage/IrritationCauses serious eye damage(Category 1)> Skin SensitizationNo information available> Respiratory SensitizationNo information available> Germ Cell MutagenicityNo information available> Carcinogenicity> Reproductive ToxicityMay damage fertility or the unborn child(Category 1)> Reproductive Toxicity (Additional)May cause harm to breast-fed children(Additional)> STOT-Single ExposureNo information available> STOT-Repeated ExposureNo information available> Aspiration HazardNo information available> Acute Aquatic Toxicity> Chronic Aquatic ToxicityNo information available> OthersPersistence and Degradability No information available Bioaccumulative PotentialNo information availableMobility in SoilNo information availableResults of PBT and vPvB AssessmentLead meet the criteria for PBT and vPvB according to Regulation (EC) No 1907/2006, annex XIII.Glass, oxide, chemicals does not meet the criteria for PBT and vPvB according to Regulation (EC) No 1907/2006, annex XIII.Sulphuric acid does not meet the criteria for PBT and vPvB according to Regulation (EC) No 1907/2006, annex XIII.Water does not meet the criteria for PBT and vPvB according to Regulation (EC) No 1907/2006, annex XIII.Waste Chemicals Before disposal should refer to the relevant national and local laws and regulation. Recommend the use of incineration disposal.Contaminated Packaging Containers may still present chemical hazard when empty. Keep away from hot and ignition source of fire. Return to supplier for recycling if possible. DisposalRecommendationsRefer to section 13.1and 13.2.Transporting Label Not applicableUN Number-UN Proper Shipping NameNOT REGULATED FOR TRANSPORT OF DANGEROUS GOODS Transport Hazard Class None Transport Subsidiary Hazard Class NonePacking Group -CommentThe sample has passed the test items of UNITED NATIONAS Recommendations on the TRANSPORT OF DANGEROUS GOODS Regulations (20th) ST/SG/AC. 10/1/Rev.20 Chapter 3.3 SPECIAL PROVISIONS 238.> International Chemical Inventory【TSCA 】 United States Toxic Substances Control Act Inventory. 【DSL 】 Canadian Domestic Substances List.【IECSC 】 China Inventory of Existing Chemical Substances. 【NZIoC 】 New Zealand Inventory of Chemicals.【PICCS 】 Philippines Inventory of Chemicals and Chemical Substances. 【KECI 】 Existing and Evaluated Chemical Substances. 【AICS 】 Australia Inventory of Chemical Substances. 【ENCS 】 Existing And New Chemical Substances. Note“√” Indicates that the substance included in the regulations “×” That no data or included in the regulationsCreation Date 2020/01/09 Revision Date2020/01/09 Reason for Revision-> DisclaimerThis Safety Data Sheet (SDS) was prepared according to UN GHS (the 7th revised edition). The data included was derived from international authoritative database and provided by the enterprise. Other information was based on the present state of our knowledge. We try to ensure the correctness of all information. However, due to the diversity of information sources and the limitations of our knowledge, this document is only for user ’s reference. Users should make their independent judgment of suitability of this information for their particular purposes. We do not assume responsibility for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product.。

海南迅捷1U系列纤薄式水化磁闸产品简介说明书

海南迅捷1U系列纤薄式水化磁闸产品简介说明书

SL1005C2BTA1SL1010C2BTA1SL1040C2BT SL1045C3BTA1SL1050C2BTA1 SL1020C2BTA1SL1035C2BTA1SL1040C2BTA2Increase Your Power DensityWith Eaton’s new Heinemann 1U Series Slimline Hydraulic Magnetic Circuit Breaker you can increase your power density without sacrificing performance. The 1U Series Slimline offers the precision performance of a full size hydraulic magnetic breaker in a miniaturized package.Designed specifically for rack-mount applications,the Slimline's reduced height is ideal for tight spaces and the protection of the latest 1U devices.The 1U Series Slimline is the first hydraulic magnetic breaker to use a snap action mecha-nism which improves reliability,safety and performance. With snap action, the contacts are controlled by a stored energy mechanism that closes in one swift action when the operator switches the handle to the ON position. This advanceddesign prevents premature contact failure, improvesefficiency and allows for higher current ratings.The 1U Series Slimline com-pact size allows greater design flexibility and saves valuablerack space without sacrificing performance. All configurations are UL ா489 listed for branch circuit protection and conform to IEC standards. Available with an integral auxiliary switch, the breaker allows for integration into the most complex systems.Take your equipment to a new level of power density and protection, never before possible. Learn about how the new Eaton 1U Series Slimline is revolutionizing the dc power protection market today.1U Series Slimline Product Highlights•Proven reliability of the Heinemann Hydraulic Magnetic Trip Unit.•Patented snap action technology for improved performance and reliability.•World’s first circuit breaker designed for 1U height rack-mount applications.•Ambient compensating trip unit from -40˚ to +80˚C.•1.0 – 100 ampere continuous current ratings (100% rated).•80 Vdc rating.•UL 489 listed.•CE mark. •Integral auxiliary switch option.•Bullet, screw or stud terminals.•Panel removal tool.•Standard distribution panel configurations available.Eaton Electrical Inc.1000 Cherrington Parkway Moon Township, PA 15108United Statestel: 1-800-525-2000© 2006 Eaton Corporation All Rights Reserved Printed in USAPublication No. PA01106001E / Z4344April 2006UL is a federally registered trademark of Underwriters Laboratories Inc. Heinemann is a federally registered trademark of Eaton Corporation.Typical DimensionsPERFORMANCE DATACurrent Range 1 – 100 A 1Continuous (100% Rated)VoltageUp to 80 Vdc or up to 240 Vac 1Interruption Rating 10 kA @ 80 Vdc 1or 10 kA @ 240 Vac 1Delay Curves Medium, Short, Instantaneous Operating Temperature -40 to + 80ºCTerminals Screw, Stud or Bullet ApprovalsUL 489 Listed, CE MarkAuxiliary Switch Rating 100 mA @ 80 Vdc or 300 mA @ 30 Vdc1Phase I Launch 5 – 60 A, 80 Vdc, 5 kA, UL 489. Consult Customer Service for availability of future releases.Catalog Number Configuration GuideUse the table below to select the correct standard catalog number for your application. Standard configuration consists of Series Trip,Imperial Mounting Inserts, UL 489 Listing and Screw Terminals. We also offer custom configurations and assembled DC distribution panels. To get additional technical assistance or for more information about custom applications, call +1 800 356 1243 (Americas), +41 21 841 92 11 (EMEA) or +86 512 6716 3397 (Asia).Auxiliary Switch OptionCATALOG NUMBERING SYSTEMNote:Catalog number example — SL1005C2.2Phase I Launch 5 – 60 A, 80 Vdc, 5 kA, UL 489. Consult Customer Service for availability of future releases.3No catalog designation is required for a standard catalog configuration.SL1005C2BTA1SL1010C2BTA1SL1040C2BT SL1045C3BTA1SL1050C2BTA1 SL1020C2BTA1SL1035C2BTA1SL1040C2BTA2。

相关主题
  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

Broadband TelCom Power, Inc.
BTCPower BTCPower
TM
Redefining “Current” Limits In Power Conversion
BAO60 Series
60W Open Frame AC-DC Power Modules
• Universal Input 90-264 Vac • PCB Mountable • Efficiency to 85%
• Industry Standard Pin Out • 100 % full load burn-in test
• ISO-9001 certified manufacturer

Short circuit / overload / over voltage protection
• Approvals: UL / TUV / CE
Specifications
Input voltage range………………………………………………………………..90-264 Vac Input frequency………….…………………………………………………………47 – 63 Hz
Inrush current………………………………………………………………………Cold start, 25A / 155Vac, 50A / 230Vac Output voltage….…………………………………………………………………..Refer to below table Initial Accuracy ………………………………………………………………….. ±1.0% max. Temperature Coefficient ………………………………………………………….±0.05% / ºC
Ripple & Noise, 20Mhz BW ………………………………………….…………. 50mVp -p, max @ 3.3/5Vo; 1%p-p,max @ other output voltage modules Hold-up time ¹ ……………………………………………………………………..8ms typ. Short circuit protection……………...………………………………………….…Continuous Line regulation ² .………………………………………………………………….±0.05% max. Load regulation ³ …………………………………………………………….……±1.0% max.
Efficiency ………..…..…………………………………………………………….Refer to below table Isolation Voltage (Input/Output) ………………………………………………...4242 Vac Operating temp. range ……………………………………………………….…..0 ºC – 50 ºC Storage temp. range ………………………..……………………………………-40 ºC – +100 ºC Cooling………………………………………………………………………………Free air convection
Part No
Output
Tolerance
Ripple
Efficiency
BAO60- UAC-3.3 3.3V, 8A +/ - 1 % 50 mV 74% BAO60- UAC-5 5V, 8A +/ - 1 % 50 mV 78% BAO60- UAC-9 9V, 6.67A +/ - 1 % 90 mV 82% BAO60- UAC-12 12V, 5A +/ - 1 % 120 mV 84% BAO60- UAC-15 15V, 4A +/ - 1 % 150 mV 85% BAO60- UAC-24 24V, 2.5A +/ - 1 % 240 mV 86% BAO60- UAC-30 30V, 2A +/ - 1 % 300 mV 86% BAO60- UAC-36 36V, 1.67A +/ - 1 % 360 mV 87% BAO60- UAC-48
48V, 1.25A
+/ - 1 %
480 mV
88%
Note: The output voltage cab be 0.1V interval changed.
元器件交易网
BTCPower BTCPower
T M
Broadband TelCom Power, Inc. – 1719 S. Grand Avenue, Santa Ana, CA 92705 U.S.A. Pg. 2.
Tel.: 714-259-4888 • Fax: 714-259-0840 • • Email: sales@ AC/DC BAO60 PS Ver1 8-7-03
Note:
1. Measured at Vin = 115 Vac, Full load
2. Measured from high line to low line
3.
Measured from full load to 10% load
4. BAO60 input connector mates with Molex housing 09-50-3031 and Molex 2878 series crimp terminal.
5.
BAO60 output connector mates with Molex housing 09-50-3041 and Molex 2878 series crimp terminal.
MECHANICAL DRAWING