EP1903119A1
欧洲产品标识号(EAN)为4030661188836的TQ 441-01 01Y-UE-R-M20产
DATASHEETDataOrdering dataProduct type description TQ 441-01/01Y-UE-R-M20 Article number (order number)101160100EAN (European Article Number)4030661188836eCl@ss number, version 12.027-37-12-01eCl@ss number, version 11.027-37-12-01eCl@ss number, version 9.027-37-12-01ETIM number, version 7.0EC002026ETIM number, version 6.0EC002026Approvals - StandardsCertificates cULusGeneral dataGross weight720 gGeneral data - FeaturesLatching YesNumber of normally closed (NC)2Electrical dataSwitching principle Slow action with overlapping contactsOrdering codeProduct type description:TQ 441-(1)(2)-(3)-(4)-(5)-(6)-M20(1)11 1 NO contacts/1 NC contact20 2 NO contacts01/01 1 NC contact for pull wire/1 NC contact for wirebreakage(2)Y IP65X IP54(3)UE With overlapping contacts(4)R With latching(5)S Release by key(6)without Preload force 220 N *-1572Preload force 60 N *-1573Preload force 35 N ** For release paths and forces, see operation andmountingPicturesProduct picture (catalogue individual photo)ID: ktq44f01| 622.0 kB | .jpg | 263.172 x 433.917 mm - 746 x 1230 px - 72 dpi| 58.6 kB | .png | 74.083 x 122.061 mm - 210 x 346 px - 72 dpiDimensional drawing basic componentID: 1tq44g01| 38.2 kB | .cdr || 10.1 kB | .png | 74.083 x 51.858 mm - 210 x 147 px - 72 dpi| 117.7 kB | .jpg | 352.778 x 247.297 mm - 1000 x 701 px - 72 dpiDimensional drawing basic componentID: 1tq44g02| 28.4 kB | .cdr || 4.2 kB | .png | 74.083 x 51.858 mm - 210 x 147 px - 72 dpi| 88.9 kB | .jpg | 352.778 x 247.297 mm - 1000 x 701 px - 72 dpiDimensional drawing basic componentID: 1tq44g03| 26.6 kB | .cdr || 3.7 kB | .png | 74.083 x 51.858 mm - 210 x 147 px - 72 dpi| 84.6 kB | .jpg | 352.778 x 247.297 mm - 1000 x 701 px - 72 dpiAssembly exampleID: ktq44m01| 139.5 kB | .cdr |Schmersal Ltd., Sparrowhawk Close, WR14 1GL MalvernThe details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.Generated on: 26/07/2023, 00:51。
菲尼克斯-EUK端子排
终端紧固件,安装在NS 32或NS 35/7,5 DIN导轨上
产品备注 EAN
4 017918 017323
符合WEEE/RoHS指令的日期: 01.07.2005
sales group 包装 关税 产品目录信息
B220 50 pcs. 39269097 页面 344 (CL2-2011) 请注意这里提供的数据来 源于在线目录。如需详细的 信息和数据,请查阅http:// 上的用户使用信息。该信息适用网络 下载的一般条款。
菲尼克斯电气 保存的技术修改内容;
Nanjing Phoenix Contact Co. Ltd.
页面 4 / 4 2011-10-28
长度 (b) 高度 厚度 (a) 颜色 阻燃等级,符合UL 94 标识材料 50,5 mm 35,3 mm 9,5 mm 灰色 V2 PA
Nanjing Phoenix Contact Co. Ltd.
页面 1 / 4 2011-10-28
菲尼克斯接线端子菲尼克斯端子菲尼克斯凤凰端子瑞弗菲尼克斯瑞凡菲尼克斯菲尼克斯塔尼特菲尼克斯杰昆菲尼克斯dnf菲尼克斯菲尼克斯太阳
E/UK
订货号: 1201442
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1201442
1051003
ZB 6:UNBEDRUCKT
1201028 1201280 1201358 1201002 1201015 0801762 0801733 0801681 1201756 1201895 1201730 1201714 1201798 NS 32 AL UNPERF 2000MM NS 32 CU/120QMM UNPERF 2000MM NS 32 CU/35QMM UNPERF 2000MM NS 32 PERF 2000MM NS 32 UNPERF 2000MM NS 35/ 7,5 CU UNPERF 2000MM NS 35/ 7,5 PERF 2000MM NS 35/ 7,5 UNPERF 2000MM NS 35/15 AL UNPERF 2000MM NS 35/15 CU UNPERF 2000MM NS 35/15 PERF 2000MM NS 35/15 UNPERF 2000MM NS 35/15-2,3 UNPERF 2000MM G型导轨32 mm (NS 32) G型DIN导轨,深长,材料: 铜,未打孔,高度15 mm,宽度32 mm,长度2 mm G型DIN导轨,材料: 铜,未打孔,高度15 mm,宽度32 mm,长 度2 mm G型DIN导轨,材料: 钢,打孔,高度15 mm,宽度32 mm,长度 2m G型DIN导轨,材料: 钢,未打孔,高度15 mm,宽度32 mm,长 度2 m DIN导轨,材料: 铜,未打孔,高度7.5 mm,宽度35 mm,长度: 2m DIN导轨,材料:钢,表面镀锌且经过钝化处理,打孔,高7.5 mm,宽35 mm,长:2000 mm DIN导轨,材料: 钢,未打孔,高度7.5 mm,宽度35 mm,长度: 2m DIN导轨,高轨,高型,未打孔,1.5 mm厚,材料:铝,高15 mm,宽35 mm,长2000 mm DIN导轨,材料: 铜,未打孔,厚度1.5mm,高度15 mm,宽度35 mm,长度: 2 m DIN导轨,材料:钢,表面镀锌且经过钝化处理,打孔,高15 mm,宽35 mm,长:2000 mm DIN 导轨材料:钢,未打孔,高度 15 mm,宽度 35 mm,长度: 2m DIN导轨,材料: 钢,未打孔,厚度2.3mm,高度15 mm,宽度35 mm,长度: 2 m
芜湖德豪润达各型号对应的光罩、产品编码
型号mask 版本号产品编号Model Name V1.0B0907AA01B0907HE V1.0B0907AA02B0907HED V1.0G0907AA01G0907HED V2.0B0907AB01B0907HEV2.0B0907AB02B0907HEDV2.0G0907AB01G0907HEDV1.0B1008AA01B1008HEV1.0B1008AA02B0907HEDV1.0G1008AA01G1008HEV1.0B1109AA01/G1109AA01B1109HE/G1109HE V2.0B1109AB01/G1109AB01B1109HE/G1109HEV1.0B1509AA01B1509THE V1.1B1509AB01B1509THEV3.0B1610AA01B1610THE1109下线Model Name 选择100809071509V4.1B1610AB02B1610THE V4.1B1610AB03B1610THE V4.1B1610AB04B1610THE V4.2B1610AC04B1610THE V1.0B2109AA01B2109THE V2.0B2109AB01B2109THEV1.0B2020AA01B2020THMV1.1B2020AA01B2020THMV1.2B2020AB01B2020THM无标注B2410AA01B2410SLV3.0B2410AB02B2410THEV3.0B2410AB03B2410THE210920201610V3.0B2410AB04B2410THE 2410V3.0B2410AB05B2410THEV3.1B2410AC04B2410THEV3.2B2410AD04B2410THEV4.0B2410AE05B2410THEV3.0B2812AA01B2812THEV3.0B2812AA02B2812THEV3.0B2812AA03B2812THEV3.0B2812AA02B2812THE 2812V4.0B2812AB01B2812THEV4.1B2812AC02B2812THERDV1.0B2812AD04B2812THEV5.0B2812AD01B2812THEV2.0B2626AA01B2626THMV2.1B2626AB02B2626THMV2.1B2626AB03B2626THM 2626V2.2B2626AC01B2626THM V2.2G2626AC01G2626THM V1.0B3030AA01B3030THM V1.0B3030AA02B3030THMV2.0B3030AB01B3030THMV2.1B3030AC01B3030THMV2.2B3030AD01B3030THMV1.0B3434AA01B3434THM26263030V1.0B3434AA02B3434THM 3434V2.0B3434AB01B3434THMV2.1B3434AC01B3434THMV1.0B4222AA01B4222THEV2.0B4222AB01B4222THE 4222V2.1B4222AC01B4222THEV1.0B4040AA01B4040THMV1.1B4040AA01B4040THMV2.0B4040AA01B4040THM 4040V2.1B4040AB01B4040THMV1.0B4545AA01B4545THMV1.1B4545AA01B4545THMV2.0B4545AB01B4545THM 4545V2.1B4545AC01B4545THMV1.0B5050AA01B5050THM 5050V2.0B5050AB01B5050THMV1.0B6060AA01B6060THMV2.0B6060AB01B6060THM 6060V2.1B6060AC01B6060THM状态图形备注量产在用普通蓝光非量产在用RGB蓝光非量产在用RGB绿光非量产在用普通蓝光非量产在用RGB蓝光非量产在用RGB绿光非量产在用普通蓝光非量产在用RGB蓝光非量产在用RGB绿光非量产TR在用非量产PIE在用非量产在用非量产在用非量产不在用量产停用Lapping:150um+/-5um量产停用Lapping:130um+/-5um量产在用在ITO和Metal酸洗前增加Wait站别量产在用非量产不在用非量产在用非量产不在用非量产在用非量产在用不在用量产ER、1BH停用Lapping:150um+/-5um量产ER、1BH停用Lapping:130um+/-5um量产ER、1BH在用在ITO和Metal酸洗前增加Wait站别量产Aixron 使用PV recipe改为:PV-test-S200非量产在用非量产在用非量产在用PV:P5000量产ER、1BH停用Lapping:150um+/-5um量产ER、1BH停用Lapping:130um+/-5um量产ER、1BH在用在ITO和Metal酸洗前增加Wait站别非量产在用非量产在用非量产在用非量产在用PV:P5000非量产在用非量产不在用量产停用量产在用在ITO和Metal酸洗前增加Wait站别非量产在用非量产在用绿光量产在用量产在用测试电流由120mA改为350mA 非量产在用非量产在用非量产在用量产停用量产在用在ITO和Metal酸洗前增加Wait站别非量产在用非量产在用非量产不在用非量产在用非量产在用非量产不在用非量产不在用非量产在用非量产在用非量产不在用非量产不在用非量产在用非量产在用非量产不在用非量产在用非量产不在用非量产在用非量产在用。
熊猫滤清器车型对应表
时代超人 志俊 熊猫编号 机油格 XO-721 燃油格 XF-1100 空气格 XA-1111 空调格 XC-1100 桑塔纳3000 熊猫编号 机油格 XO-721 燃油格 XF-1100 空调格 XA-1111 空调格 XC-1100 09款上海大众朗逸1.6 熊猫编号 机油格 XO-722 燃油格 XF-1122 OEM NO. 备注 OEM NO. 备注 OEM NO. 034-115-561 251-201-511A 330-129-620 备注
空气格 XA-1155 空调格 XC-1155 新宝来1.4TSI 熊猫编号 机油格 XO-722 燃油格 XF-1188 空气格 XA-1122 空调格 XC-1180 OEM NO. 备注
空气格 XA-1188 空调格 XC-1188 奥迪A4L 2.0T 熊猫编号 机油格 XO-723 燃油格 XF-1033 空气格 XA-1088 外空调 XC-1087 格 内空调 XC-1088 格 A6L 2.0T 备注 熊猫编号 机油格 XO-800 燃油格 XF-1000 空气格 XA-1011 空调格 XC-1010 4F0133843A 4F0819439A OEM NO. 06D115 562 备注 OEM NO. 068 115 561B 002 477 3001 027 129 620 OEM NO. 备注
捷达王 O511A 1GD129620 191 819 640 备注
大 众 系 列
熊猫编号 机油格 XO-721 燃油格 XF-1110 空气格 XA-1122 空调格 XC-1155
OEM NO. 06A115561B 1J0201511A 1J0129620 6Q0819 638
油箱不能用
大众劲情劲取 备注 熊猫编号 机油格 XO-810 燃油格 XF-1122 空气格 XA-1155 空调格 XC-1155 OEM NO. 03C115562A 6Q0 201 511B 03C 129 620F 6Q0-819-653 备注
EPI9L6142KSP45L中文资料
.270 (6.86)
.270 Max. (6.86)
.260 (6.60)
Note: Coplanarity within .005” Max.
PCA ELECTRONICS, INC. 16799 SCHOENBORN ST. NORTH HILLS, CA 91343
Unless Otherwise Specified Dimensions are in Inches /mm ± .010 /.25
L
.330 .435 .425 .500 .500 .555 .600 .585 .650 .865 .670 .940 1.11 1.220 .880 .195 .195 .224 .264 .264 .287 .287 .402 .472 .472 .472 .177 .394 .394 .460 .460 .560
1.05 5.2 7.5 10.9 16.8 25 36.5 51.6 75 110 166 248
Байду номын сангаас
DCR (Ω Typ.)
.011 .051 .061 .094 .148 .224 .343 .408 .625 .958 1.476 2.225
Induct. (µH 15%)
@ Idc
0.9 4.7 6.8 10 15 22 33 47 68 100 150 220
元器件交易网
Surface Mount Power Inductor
ELECTRONICS INC.
EPI B30 Series
• Optimized for National’s LM259X Series • Low loss material ensures operation in high frequency switching
莫克A DA-720系列 x86 2U 19英寸 14Gigabit Ethernet高接口密度机械
DA-720Seriesx862U19-inch14Gigabit Ethernet high interface-density rackmount computers with6th Gen Intel®Core™i7CPUFeatures and Benefits•IEC61850-3,IEEE1613,and IEC60255compliant for power substationautomation systems•EN50121-4compliant for railway wayside applications•6th Gen Intel®Core™i7/i5CPU(Skylake)•2built-in DDR4memory sockets•1mSATA for OS and1SATA III for storage expansion•14Gigabit Ethernet ports for network redundancy•3PCIe expansion slots for expansion modules•4USB ports for high-speed peripherals•2isolated RS-232/422/485ports•Embedded Debian8Linux(W10by CTOS)•Highly reliable design,supporting dual power and PRP/HSR technology(withPRP/HSR expansion module)CertificationsIntroductionThe DA-720Series computers are x86platforms with14Gigabit Ethernet ports,2isolated RS-232/422/485serial ports,USB,VGA,and3PCIe ports for expansion modules.The DA-720comes in a standard19-inch2U rack-mountable case with a robust design ideal for specialized industrial automation applications,including power substations,transportation and shipping,and oil and gas production and supply.With IEC-61850-3and IEEE1613compliance,the DA-720is sure to deliver stable and reliable system operation for power applications.The DA-720 also complies with the IEC60255standards,which cover the protection of electrical relays in a smart substation.IEC60255is one of the most widely used standards for testing relays and protection equipment,and compliance with the standard ensures that the DA-720will work reliably and seamlessly with IEDs as part of a robust substation automation system.EN50121-4compliance confirms that the DA-720can deliver stable and reliable system operations in rail wayside applications,such as station SCADA systems,wayside disaster prevention,traction power,and signaling and safety systems to provide an integrated view of your smart rail setup.The DA-720comes with two different CPU options and basic models that allow system designers to install the mSATA,RAM,and operating system according to their specific requirements.Such a wide choice of options is particularly welcome when it comes to designing customized industrial solutions.The DA-720comes with3PCIe ports for expansion modules,including an8-port RS-232/422/485module,4-port and8-port10/100/1000Mbps LAN modules,a2-port100/1000Mbps PCIe PRP/HSR LAN module,a dual2.5”SATA III SSD/HDD socket module,and a2-port IRIG-B time-synchronization module with a4DI/DO module.The DA-720computers can support up to22Gigabit LAN ports plus16serial ports,or14Gigabit LAN ports and24serial ports,making the DA-720an ideal solution for a wide range of industrial automation applications.The PRP-HSR expansion module is compliant with IEC62439-3Clause4(PRP)and IEC62439-3Clause5(HSR)to ensure the highest system availability and data integrity for mission-critical applications that require redundancy and zero-time recovery.With dual Gigabit Ethernet port design,the DE-PRP-HSR-EF provides high performance for redundant network systems.Moxa’s DA-720Series industrial computer with the DE-PRP-HSR-EF is the ideal solution for power substation automation and process automation systems.Smart Recovery FunctionThe DA-720’s Smart Recovery function minimizes downtime by making it easy to recover from operating system crashes.Engineers who are experts in a particular vertical market may not have enough computer domain knowledge to know how to fix operating system problems.Moxa Smart Recovery™is an automated BIOS-level software recovery system that allows engineers to automatically trigger OS recovery to minimize downtime.Proactive Monitoring FunctionMoxa Proactive Monitoring is a small-footprint,resource-friendly,easy-to-use utility that allows users to track a number of system parameters. Users can view the current parameter values for these key parts by simply clicking on the icons corresponding to the parameters in the user er-defined key part indicators(KPIs)are used to monitor the computer’s key parts.Visible and/or audio alerts are triggered automatically via relay and SNMP traps when these KPIs exceed their preset threshold values,making it extremely convenient for operators to avoid system downtime by setting up predictive maintenance tasks well in advance.AppearanceFront ViewRear ViewSpecificationsComputerCPU DA-720-C5-DPP Series:Intel®Core™i5-6300U Processor(3M Cache,up to3.00GHz)DA-720-C7-DPP Series:Intel®Core™i7-6600U Processor(4M Cache,up to3.40GHz) Graphics Controller Intel©HD Graphics520(integrated)System Memory Pre-installed DA-720LX Series:4GB DDR4System Memory Slot SODIMM DDR4slot x2Pre-installed OS DA-720LX Series:Linux Debian864-bitSupported OS Linux Debian8(Linux kernel v4.1)Windows10Embedded IOT Ent2016LTSB High End EPKEAWindows10Embedded IOT Ent2016LTSB Value EPKEANote:W10available by CTOSStorage Slot 2.5-inch HDD/SSD slots x1mSATA slots x1,internal mini-PCIe socketStorage Pre-installed DA-720LX Series:8GB mSATAComputer InterfaceEthernet Ports Auto-sensing10/100/1000Mbps ports(RJ45connector)x14Serial Ports RS-232/422/485ports x2,software-selectable(terminal block)USB2.0USB2.0hosts x2,type-A connectors(front) USB3.0USB3.0hosts x2,type-A connectors(rear) Expansion Slots Proprietary PCIe slot x3Video Input DVI-D x1,29-pin DVI-D connectors(female)VGA x1,15-pin D-sub connector(female) LED IndicatorsSystem Power x1Storage x1Programmable x4LAN1per port(10/100/1000Mbps)Serial2per port(Tx,Rx)Serial InterfaceBaudrate50bps to115.2kbpsConnector Terminal blockESD8kV(level4)Isolation2kVSerial Standards RS-232/422/485Surge2kV:line-to-line4kV:line-to-groundSerial SignalsRS-422Tx+,Tx-,Rx+,Rx-,GNDRS-485-2w Data+,Data-,GNDRS-485-4w Tx+,Tx-,Rx+,Rx-,GNDRS-232TxD,RxD,RTS,CTS,GNDPower ParametersInput Current0.82A@100VAC0.77A@110VDCInput Voltage100to240VAC,110to240VDCPower Button Reset button(front panel)ON/OFF(rear panel)Physical CharacteristicsHousing MetalDimensions(without ears)440x301x90mm(17.32x12.20x3.54in) Weight6,500g(14.33lb)Installation19-inch rack mountingEnvironmental LimitsOperating Temperature-25to55°C(-13to131°F)Storage Temperature(package included)-40to85°C(-40to185°F)Ambient Relative Humidity5to95%(non-condensing)Standards and CertificationsEMC EN55032/24EMI CISPR32,FCC Part15B Class AEMS IEC61000-4-11DIPsIEC61000-4-2ESD:Contact:8kV;Air:15kVIEC61000-4-3RS:80MHz to1GHz:20V/mIEC61000-4-4EFT:Power:4kV;Signal:4kVIEC61000-4-5Surge:Power:4kV;Signal:4kVIEC61000-4-6CS:10VIEC61000-4-8:20A/mPower Substation IEC61850-3,IEEE1613Protection Relay IEC60255Railway EN50121-4Safety EN60950-1,IEC60950-1,UL60950-1Shock IEC60870-2-2,IEC61850-3Edition1.0Vibration IEC61850-3,IEC60870-2-2DeclarationGreen Product RoHS,CRoHS,WEEEMTBFTime138,319hrsWarrantyWarranty Period3yearsDetails See /warrantyPackage ContentsDevice1x DA-720Series computerInstallation Kit1x rack-mounting earDocumentation1x quick installation guide1x warranty cardNote This product requires additional modules(sold separately)to function.DimensionsOrdering InformationModel Name CPU DDR4RAM OS Storage(mSATA)Linux Debian864-bitPower Input100-240VAC110-240VDCOperating Temp.DA-720-C5-DPP i5-6300U–––✓-25to55°C DA-720-C5-DPP-LX i5-6300U4GB8GB✓✓-25to55°C DA-720-C7-DPP i7-6600U–––✓-25to55°C DA-720-C7-DPP-LX i7-6600U4GB8GB✓✓-25to55°C Accessories(sold separately)Expansion ModulesDE-LN04-RJ4-port100/1000Mbps PCIe LAN moduleDE-LN08-RJ8-port100/1000Mbps PCIe LAN moduleDE-PRP-HSR-EF2-Port100/1000Mbps PCIe PRP/HSR LAN ModuleDE-SP08-I-TB8-port RS-232/422/485PCIe serial moduleDE-2-SATA2x2.5”SATA III SSD/HDD Socket ModuleDE-2-IRIGB-4-DI/DO2-port IRIG-B time synchronization module with4DI/DOStorage KitsDA-720HDD Kit DA-720HDD/SSD kitUSB Dongle KitsUSB Dongle Kit Internal USB dongle kit installation package©Moxa Inc.All rights reserved.Updated Jan31,2019.This document and any portion thereof may not be reproduced or used in any manner whatsoever without the express written permission of Moxa Inc.Product specifications subject to change without notice.Visit our website for the most up-to-date product information.。
戈顿NGC系列电子纸箱电路保护设备说明书
Eaton NGH212033EEaton Series G electronic molded case circuit breaker, NG-frame, NG, Digitrip 310 RMS, Electronic LS trip, Two-pole, 1200A, 480 Vac, 100 kAIC at 240 Vac, 65 kAIC at 480 Vac, Line and load, Imperial, 50/60 Hz, 80% ratedGeneral specificationsEaton Series G electronic molded case circuit breakerNGH212033E 7866856092636 in9 in9 in 48 lb Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.UL Listed Product NameCatalog NumberUPCProduct Length/Depth Product Height Product Width Product Weight WarrantyCertificationsSeries GImperial100 kAIC at 240 Vac 65 kAIC at 480 VacNGNG80% rated50 to 60 HzLine and load480 Vac1200 AElectronic LSTwo-pole Application of Tap Rules to Molded Case Breaker Terminals Application of Multi-Wire Terminals for Molded Case Circuit BreakersMulti-wire lugs product aidPower metering and monitoring with Modbus RTU product aidHigh performance operating handles for Series G circuit breakers product aidStrandAble terminals product aidMotor protection circuit breakers product aidComprehensive circuit protection for control panel applicationsCurrent limiting molded case circuit breaker module for series G, JG and CLPlug-in adapters for molded case circuit breakers product aidCircuit breaker motor operators product aidCurrent limiting molded case circuit breaker module product aidSeries G MCCB quick selectorMolded case circuit breakers providing higher levels of selective coordination product aidJ-Frame 310+ and L-Frame 310+ Molded-case circuit breakers Breaker service centersEaton's Volume 4—Circuit ProtectionMolded case circuit breakers catalogInstruction Leaflet for Drawout Cassette for NG Frame Circuit BreakersNG and ND-Frame molded case circuit breakersEaton Specification Sheet - NGH212033EMOEM MCCB product selection guideSeriesMounting hardware Interrupt rating FrameCircuit breaker type RatingFrequency rating TerminalsVoltage rating Amperage Rating Trip TypeNumber of poles Application notesBrochuresCatalogsInstallation instructions Specifications and datasheetsEaton Corporation plc Eaton House30 Pembroke Road Dublin 4, Ireland © 2023 Eaton. All Rights Reserved. Eaton is a registered trademark.All other trademarks areproperty of their respectiveowners./socialmedia。
GigaSPEED XL 3071E-B ETL Verified Category 6 U UTP
GigaSPEED XL® 3071E-B ETL Verified Category 6 U/UTP Cable, lowsmoke zero halogen, white jacket, 4 pair count, 1000 ft (305 m) length,reelProduct ClassificationRegional Availability EMEAPortfolio SYSTIMAX®Product Type Twisted pair cableProduct Brand GigaSPEED XL®General SpecificationsProduct Number3071EANSI/TIA Category6Cable Component Type HorizontalCable Type U/UTP (unshielded)Conductor Type, singles SolidConductors, quantity8Jacket Color WhitePairs, quantity4Separator Type BisectorTransmission Standards ANSI/TIA-568.2-D | CENELEC EN 50288-6-1 | ISO/IEC 11801 Class E DimensionsCable Length304.8 m | 1000 ftDiameter Over Insulated Conductor 1.041 mm | 0.041 inDiameter Over Jacket, nominal 5.918 mm | 0.233 inJacket Thickness0.559 mm | 0.022 inConductor Gauge, singles23 AWG13Page ofCross Section DrawingElectrical Specificationsdc Resistance Unbalance, maximum 5 %dc Resistance, maximum7.61 ohms/100 m | 2.32 ohms/100 ftDielectric Strength, minimum2500 VdcMutual Capacitance at Frequency 5.6 nF/100 m @ 1 kHzNominal Velocity of Propagation (NVP)70 %Operating Frequency, maximum300 MHzOperating Voltage, maximum80 VRemote Powering Fully complies with the recommendations set forth by IEEE 802.3bt (Type4) for the safe delivery of power over LAN cable when installed accordingto ISO/IEC 14763-2, CENELEC EN 50174-1, CENELEC EN 50174-2 or TIATSB-184-ASegregation Class cMaterial SpecificationsConductor Material Bare copperInsulation Material PolyolefinJacket Material Low Smoke Zero Halogen (LSZH)Separator Material PolyolefinPage of23Mechanical SpecificationsPulling Tension, maximum11.34 kg | 25 lbEnvironmental SpecificationsInstallation temperature0 °C to +60 °C (+32 °F to +140 °F)Operating Temperature-20 °C to +60 °C (-4 °F to +140 °F)Acid Gas Test Method EN 50267-2-3EN50575 CPR Cable EuroClass Fire Performance B2caEN50575 CPR Cable EuroClass Smoke Rating s1aEN50575 CPR Cable EuroClass Droplets Rating d0EN50575 CPR Cable EuroClass Acidity Rating a1Environmental Space Low Smoke Zero Halogen (LSZH)Smoke Test Method IEC 61034-2Packaging and WeightsCable weight38.097 kg/km | 25.6 lb/kftPackaging Type ReelRegulatory Compliance/CertificationsAgency ClassificationCENELEC EN 50575 compliant, Declaration of Performance (DoP) availableCHINA-ROHS Below maximum concentration valueISO 9001:2015Designed, manufactured and/or distributed under this quality management system REACH-SVHC Compliant as per SVHC revision on /ProductCompliance ROHSCompliantPage of33。
派克液压密封件说明书
派克汉尼汾公司版权所有未经许可不能摘录,翻印。
保留修改权利2021年6月警告销售条件本样本中产品和/或系统或相关产品出现故障,选型不当或使用不当,均可能导致人身伤亡和财产损失。
本文档以及由派克·汉尼汾公司及其子公司和授权经销商提供的其他资料,为具有技术知识的用户提供进一步研究所需的产品和/或系统选项。
重要的是,用户必须对您的应用进行全面的分析,并对当前产品样本中与产品或系统相关的资料进行评估。
由于工作条件以及产品或系统的多样性,用户必须自行分析和测试,并独自承担一切后果,包括:产品和系统的最终选型以及确保满足应用的所有性能、安全和警告等方面的要求。
派克·汉尼汾及其子公司可能会随时对本样本中的产品,包括但不限于:产品的特性、产品的规格、产品的结构、产品的有效性以及产品的价格作出变更而不另行通知.本样本中的所有产品均由派克·汉尼汾公司及其子公司和援权经销商销售。
与派克签订的任何销售合同均按照派克标准条件和销售条件中规定的条款执行(提供复印件备索)。
本公司的密封件,只能在本公司的文件资料述及的应用参数范围与接触介质、压力、温度和存放时间相一致的情况下才能使用。
在规定的应用参数范围外使用以及错误选用不同的材料都可能导致密封件寿命的缩短以及设备的损坏,甚至更严重的后果(如生命安全,环境污染等)。
样本中所列出的工作压力、温度范围、运动速度是极限值,它们之间相互关联、相互影响;在极端的工况下,建议不要同时把各个参数都同时用到极限值。
对于特殊的要求(压力、温度、速度、介质等),请联系派克汉尼汾公司以咨询合适的密封结构、材料、配置、安装建议等。
由于诸多工作参数会影响到流体传动系统及密封元件,这些设备的制造商必须在实际工作条件下测试、验证并批准密封系统的功能与可靠性。
此外,对于不断出现的新的介质(液压油、润滑脂、清洗剂等),用户特别注意它们与目前所用的密封件弹性体材料的兼容性。
我们建议用户在大批量应用之前,在厂内或现场先做密封材料的兼容性能测试,作为密封产品与系统供应商,我们建议用户遵循我们的这些建议。
模型19032 19032-P电子安全分析仪功能特性说明书
General Electrical Safety Testing SolutionElectrical safety testing is one of the major itemsin the electrical product quality tests. All electricalproducts consisting of adapter, SMPS, charger,house appliance, information technology productand video products are required to performelectrical safety test.The 19032 series combines Hipot, InsulationResistance( IR), Ground Bond (GB), LeakageCurrent (LC)/AC LC/DC LC and Dynamic FunctionTest. Savings can be up to 50% of productionline space, by not purchasing several safetytest instruments. The 19032 is able to increaseefficienc y of electrical safety test duringmanufacturing and reduce the labor cost on thesetest.Open/Short Check (OSC)Patent No. : 254135All manufacturers have to solve the problems oferror connections and unconnected test cableswith their production line testers. Chroma's 19032is equipped with an open/short check function(OSC) for product testing. This eliminates thepotential for false failures.Twinport TM FunctionUSA Patent No.: US6504381The key factor affecting the efficienc y ofmanufacturing is the efficiency for electrical safetytest. The Twinport function reduces the safety testtime and can eliminate potential bottlenecks inthe production line.Product ApplicationThe 19032 series can be applied to versatiletest of electrical products, which includequality assurance sampling inspection test,manufacturing test and development validation.• Power cord• House appliances• Information technology product• Medical equipment• Lab/testing equipment• EMI FILTER• Electric Vehicles• Solar, PV inverterEN50191 Floating Output FunctionThe leakage current of any ground terminal shouldbe lower than 3.5mA when operating Floatingoutput function. This allows the operator near theground terminal to avoid an electrical hazard. ELECTRICAL SAFETY ANALYZER MODEL 19032/19032 PPATENT NO. 254135The OSC function is used to check if the connection is open (bad contact) or short (DUT short) during the test procedure. When a circuit is open during EST testing, bad product can pass as good product. When a short occurs during testing, proper screening can reduce the damage on the DUT.DUT's have capacitive loads (Cx) from tens of pF to several uF, in a normal state. A micro capacitance will occur on an open circuit interface once the connection is interrupted (as Cc in gure 2). In general, the capacitance is lower than 10pF; thus the total capacitance is lower than normal product. The capacitance is far higher than normal when the DUT is short or close to a short. This allows users to judge the short issue by using high/low limit values of capacitance change.Manufactures apply Chroma's AC source as a power supply to increase the input voltage stability for dynamic leakage current test. The 19032 uses RS232 interface to control the AC source and allows convenience in running the leakage current test.Chroma 6400/ 6500/ 61500/ 61600 SeriesFigure 1 : Normal Leakage Current WaveformFigure 2 : Leakage Current Waveform when ashover occurredFigure 1 : Normal Connection Figure 2 : Connection OpenFigure 3 : Connection ShortUSA PATENT NO. US6504381The 19032 electrical safety tester has Twinport ™ Technology. This patent and unique feature allows both hipot and ground bond to be tested simultaneously. This is idea for production test, as it allows test time be reduced by 50%.The 19032 has Flashover Detection, as other Chroma test instruments. Flashover is electricity transient or non-sequential discharge generated by the inner or surface of insulation components, which causes DUT's to lose the original insulation feature. Electrically generated carbonation of conductive material can damage the product. Test voltages or shift rate of leakage current is required. Flashover cannot be detected by a leakage current test, which makes the Flashover Detection a valuable tool in High Voltage testing.To allow for operator safety, Chroma invented the Floating Circuit, which is based on leading technology. With Floating status, the grounding leakage current will not exceed 3.5mA, no matter what the withstand voltage is. This complies with EN50191 for outputting to ground terminal within current limit and for protecting the operator from electric shock.The High Limit of Hipot test currently ranges from 5 -10mA. However, there are other DUT's such as Safety Integrated Analyzer of EMI Filter or large motors requiring a large amount of power. The 19032-P enhances the power of the 19032 to equip the capabilities of outputting and measuring AC 100mA/DC 25mA.This is used to integrate the high charge current for other safety test, as any integrated analyzer for use with high leakage current or large-sized electrical safety equipment. This maximizes the e ciency of the production line and quality assurance.The design of the 500VA complies with the requirement of IEC/UL output power to add the selection function of no protection for trip circuit under short current 200mA and 100mA .The ultimate purpose of safety testing is to protect users for electrical hazard. The 19032-P has a GFI function to protect the operator. The GFI function can cut-o the power output immediately, while human body is experiencing electric shock. The GFI function detects the current from the Earth (operator) and LOW terminal (device). The voltage output will be cut-o , if the current is over 0.5mA.The current brimmed after ow through insulation resistance, is called Leakage Current. When the leakage current goes through the human body, the current flows to Earth via the human body. The leakage current is testing under an operating state. The human body RC network will be added to leakage current in real conditions.The leakage current has different testing modes and standards in accordance with the di erent safety test and test points. The most common test are Earth Leakage Current, Patient Leakage Current and Patient Slave Leakage Current. The 19032 is used with different dynamic leakage current modules and human body simulation, equivalent circuit for the requirements of various safety modules. It can apply to Electrical Safety Testing for Household Appliances, VideoProduct, Medical Equipment and etc.POWER SUPPLIES(SMPS), ADAPTER AND CHARGER SAFETY TESTINGInformation technology is a big part of our daily life. Desktop, notebook, LCD monitor, UPS, printer and projector are the products that we use in our everyday lives. To ensure proper safety, all products should have electrical safety test preformed. The 19032 o ers all functions of safety test and Normal/Reverse as well as Single Fault switch function (LC Test) to increase manufacturing e ciency.The output floating of Telecommunication Network in IEC 60950 to perform dynamic leakage current test is required. The equivalent stray capacitance will also be generated on an isolation transformer, even if it is a floating circuit. The stray capacitance results in leakage current and electric shock to the users. The 19032, along with the 6000-05/07/08 leakage current scanner, have P1/P2 measurement function which is able to measure dynamic leakage current on output terminals. It is the best solution for testing information technology products.MAIN TEST ITEM • Open Short Check • Ground Bond • AC/DC Hipot Test• Earth Leakage Current Test • Output Leakage Current TestPower supplies of electronic products, including SMPS, Adapter and chargers, need to preform electrical safety test. According to various power design methods and test conditions, the 19032 o ers programmable edit and solution, allowing the operator to complete all test at one time.A number of power products designs have the insulation capability of input terminal (Primary) to output terminal (Secondary) required to protect the damage inside the component. Thus, the output terminal of Floating needs to perform Hipot test. The 19032 provides an isolation test point with high voltage which allow you not to change the xture or cable manually, but perform P-S Hipot test directly after P-G Hipot test.If there is danger in making contact with the output terminal (Secondary), dynamic leakage current test also need to be performed.LED in the lighting industry is widespread and are being used in a variety of products. EachLED and power product needs to be tested for withstand voltage, insulation, groundingresistance and leakage current , for protection from personnel electric shock.Chroma19032 with 4HV/4GC ScannerVideo products include DVD recorders, LCD's, TV's, audio amplifiers, stereos and etc. These products have mass power output with separate safety standards. The main circuit design of mass power is a signal output terminal, not to mention an increase in temperature and heat dissipation of electronic component. Open voltage of some video products are over 35Vac peak or 60Vdc peak; this allows for U1 dynamic leakage current test as required. A U1 measurement circuit is added to the 19032 and P1/P2 measurement point is provided to comply with the requirement of safety standard test.MAIN TEST ITEM• Open Short Check• Ground Bond• AC/DC Hipot TestRefer to UL 60601-1 fig. 18 Measuring circuit for the Enclosure Leakage CurrentHousehold appliances consist of ovens, refrigerators, televisions, juicers and coffee machines that may come in contact with a person. To ensure the safety of users, all products should preform electrical safety test. Except for the basic hipot test, dynamic leakage current has various test regulations by different ground modes and operation methods. The regulations are as listed in the table below.MAIN TEST ITEM • Open Short Check • Ground Bond • AC/DC Hipot Test• Earth Leakage Current TestThe 19032 + 6000-08 is a solution for electrical safety and function test of medical equipment. The safety standard of medical equipment is very strict. Since the medical equipment comes in contact with the patient and hospital personnel, the instrument preforms various electrical safety test. The leakage current test has become one of the most important test in preforming electrical safety test.The safety standard of medical equipment has various types of leakage current test. Also, normal/reverse/single fault normal/single fault reverse four powers and earth switch, make the safety test difficult and complex. The basic measuring circuit for the enclosure leakage current is as in the figure. It shows here measurement Type BF and CF is a special requirement for medical equipment. DC leakage current should be isolated separately and limited within 50uA limited, which is mentioned in the medical safety standard. This function has already been added to the 6000-08 LC scanner. The Chroma 19032 + 6000-08 offer programmable editing and software support. This allows you to test medical products without missing a procedure, as it saves the test data directly, providing the best test solution.MAIN TEST ITEM • Open Short Check • Ground Bond • AC/DC Hipot TestThe Automotive industry has switch focus from internal combustion engine power to electric power. Because the voltage of electric vehicle will be a maximum of up to 600V when in operation, it is a safety issue. To avoid electrical injury, theChroma 19032 is the best solution for electrical safety test of wire and connectors of electricalvehicles, adapters, batteries and the charging system.MAIN TEST ITEM• Withstand Voltage Test : Various insulation terminals, primary and uncharged metal, withstand voltage between primary and secondary.• Leakage Current: All metallic parts can be touched on the system reguired to test earth leakage current during dynamic operation.• Ground Test: Ground protection connection should use 25A/60Hz current to test resistance, it cannot be higher than 100m . References : IEC 62196-1,61815 UL 2594, 2202,2251• Earth Leakage Current Test • Output LC Test • Earth Leakage Current Test • Enclosure LC • Patient LC• Patient Auxiliary LCChroma provides related optional test optional xtures for di erent test requirements .• Isolation Transformer : The isolation transformer is an auxiliary and the DUT oating is connected while performing leakage current test. The above are described in the safety standard.• Dummy Load : The main function of the xture is to con rm the normality of the instrument before daily power on.• Bar-code Scanner : It can connect with 19032/19032-P directly.• Current Transformer : It is able to rise ground bond test to 40A or 60A. (Model 19032 only)• Universal Corded Product Adapter : Using this adapter can perform test directly for various types of plug in di erent countries.Di erent safety standards have various leakage current requirements which include test method and max. current output. Chroma 19032/19032-P is able to combine di erent scanners for safety needs. As the table list below.OPTIONAL FIXTURESEST software can control Chroma 19032/19032-P to perform electrical safety integrated test. Having EST software, you can save the test procedure and datadirectly as well as converting them to EXCEL file for the convenience of management and statistical analysis.EST SOFTWAREIsolation Transformer Dummy Load Current TransformerUniversal Corded Product Adapter• Program edit and GO/NG control • Data bank• Report function• Statistical analysis function• Authority management functionModel 19032-P1. Power Switch2. LCD Display3. Stop Key4. Start Key5. Cursor Keys6. TEST Key7. PRINT Key 8. SYSTEM Key 9. Cal-Enable (19032)10. DATA Entry Key 11. Function Key 12. HV Output 13. DRIVE+14. SENSE+15. SENSE-16. DRIVE-17. Update Enable (19032)18. Remote I/O19. Line Voltage Selector 20. Power Cord Receptacle 21. GND Terminal22. GPIB Interface 23. SCAN Interface 24. Fan25. Rear Panel Output 26. I/O Control (9 pin)27. Scan Box 28. RS232 Interface29. Data Entry Keys/Program Keys 30. PASS Indicator 31. FAIL Indicator 32. DANGER Indicator 33. Floating Output (19032-P)34. USB Interface (19032-P)Model 1903211 29 6 7 8 30 31 32122 9 17 5 10 13 14 15 1634125 22 23 28 19 26 2127 18 24 2011 29 6 7 8 30 31 32341332 5 10 13 14 15 1625 34 22 2123 27 28 1820ORDERING INFORMATION19032-E-201404-PDFWorldwide Distribution and Service NetworkJAPANCHROMA JAPAN CORP .472 Nippa-cho, Kouhoku-ku, Yokohama-shi, Kanagawa,223-0057 JapanTel: +81-45-542-1118Fax: +81-45-542-1080http://www.chroma.co.jp E-mail:******************U.S.A.CHROMA SYSTEMS SOLUTIONS, INC.19772 Pauling,Foothill Ranch, CA 92610 Tel: +1-949-600-6400Fax: +1-949-600-6401 E-mail:*******************Developed and Manufactured by :CHROMA ATE INC.HEADQUARTERS66 Hwaya 1st Rd., Kueishan Hwaya Technology Park,Taoyuan County 33383,TaiwanTel: +886-3-327-9999Fax: +886-3-327-8898 E-mail:******************EUROPECHROMA ATE EUROPE B.V.Morsestraat 32, 6716 AH Ede,The Netherlands Tel: +31-318-648282Fax: +31-318-648288 E-mail:******************CHINACHROMA ELECTRONICS (SHENZHEN) CO., LTD.8F, No.4, Nanyou Tian An Industrial Estate, Shenzhen, China PC: 518052Tel: +86-755-2664-4598Fax: +86-755-2641-962019032-P : Electrical Safety Analyzer 500VA 19032 : Electrical Safety Analyzer A190301 : 8HV Scanning Box A190302 : 5HV/3GC Scanner A190303 : 3HV/5GC Scanner A190304 : 8HV ScannerA190305 : Line Leakage Current Scanner (generally)A190306 : Hipot/Line Leakage/Probe Scanner (10A)A190307 : L-N Scanner & Leakage Current Scanner A190308 : Hipot/Line Leakage/Probe Scanner (20A)A190313 : 500VA Isolation Transformer A190314 : 1000VA Isolation Transformer A190316 : Dummy Load A190317 : Bar Code ScannerA190334 : Ground Bond 40A (19032)A190336 : 8HV/8GB Scanning Box A190337 : Ground Bond 60A (19032)A190338 : 19001 EST SoftwareA190343 : 19" Rack Mounting Kit (19032)A190344 : HV GunA190349 : Universal Corded Product Adapter A190350 : HV/LC/LAC/DC Probe Scanner (20A)A190353 : 4HV/4GC ScannerA190355 : 19" Rack Mounting Kit (19032-P)A190356 : GPIB Interface (19032-P)A190508 : GPIB Interface (19032)A190708 :ARC Verification Fixture。
意奔玛滤清器车型对应表
日 产 系 列
奇骏 OEM NO. 15208-65F00 16400-2Y505 16546-V1092 机油格 汽油格 空气格 空调格 阳光05款 意奔玛编号 机油格 燃油格 空气格 空调格 日产逍客 意奔玛编号 机油格 燃油格 空气格 空调格 日产新天籁 YBM522004 YBM822053S YBM322016 YBM322034C 意奔玛编号 机油格 燃油格 空气格 YBM322035 YBM322033C 空调格 日产锐祺柴油2.5 意奔玛编号 机油格 燃油格 空气格 空调格 东风思域 意奔玛编号 机油格 汽油格 空气格 空调格 YBM533004 YBM333023 OEM NO. 15400-PLC-004 YBM510055 YBM866016 YBM322032 OEM NO. YBM522004 备注 OEM NO. 备注 522007 822050S 322001 OEM NO. 备注
空调格 一汽速腾 开迪 意奔玛编号 机油格 汽油格 空气格 空调格 迈 腾 1.8T 明锐1.8T 意奔玛编号 机油格 汽油格 空气格 空调格 512041 812021 312043 312036C 意奔玛编号 机油格 汽油格 空气格 空调格 宝来1.8 1.6 意奔玛编号 机油格 汽油格 空气格 空调格 512001 812004M 312011 312018C 意奔玛编号 机油格 汽油格 空气格 空调格 桑塔纳3000 意奔玛编号 机滤 燃滤 空滤 空调滤 512001 812003 312007 312047C 意奔玛编号 机油格 512048 OEM NO. 512001 812003 312007 OEM NO. 06A115561B 1J0201511A 1J0129620 6Q0819 638 512007 812008 312013 312018C OEM NO. 06J 115 561 B 1K0 129 620 D/G 备注 YBM512001 YBM812016 YBM312031 OEM NO. 056 115 561A 6Q0 201 511B 1K0 129 620C 备注
电路板型号
延时电路板EL-T5226.00A ZS99-03-20-10DL 捣固油门电机控制板EL-T5882.02TE188-231000DL稳定油门电机控制板EL-T5630.02C TE188-361000DL 防锁定控制板EL-T5937.002TE188-232000DL 二极管板EL-T5234TET112-14-10-00DL电阻板EL-T5923TE188-101000DL 报警电路板EL-T5255.02b TET111-03-30-00DL 8通道记录仪求和放大板EL-5608.02a TE188-038/00DL40路模拟量选择控制板EK-207V-00a ZS99-04-35-10-2DL 五路测量信号选择板EL-T5721.02TE188-012100DL五路位置信号选择板EL-T5722.02TE188-012200DL四路差值信号选择板EL-T5889.02TE188-012400DL 模拟求和放大板EL-T5093.02a TE188-061000DL 四继电器板EL-T1163.00ZS99-02-30-20-ADL五继电器板EL-T5096.00ZS107-05-10-00DL延时继电器板EL-T5227.00TET111-08-30-10DL+5V电源板EL-805SV-00D TET112-01-31-00DL ±15V,±10V,+5V EL-819SV-01D TE188-032300DL捣固程控主机板EK-650PX-00TE188-055400DL 子程序板EK-651P-00TET121-01-41-00DL 程控输入输出板EK-653P-00TET112-01-33-00DL 程控定时器EK-657P-00A TET112-01-34-00DL 程控定时器板EK-652P-00A TET112-01-51-00DL程控定时板EK-662P-02a TE188-055200DL 程控看门狗电路板EK-658P-02TE188-055300DL程控功率输出板EK-654P-02-IR TE188-057200DL40路串行数据输入板EK-432DV-00TE188-055500DL40路串行数据输出板EK-433DV-00TE188-055600DL EA功率输出板EL-T5534.002IR-B TE188-213000DL一继电器板 EL-T5301.00TET111-35-10-00DL 走行驱动控制板EK-3166LV-02TE188-054600DL走行速度显示板EK-2408LV-02TE188-054700DL走行速度控制板EK-3144LV-02TE188-054800DL捣固装置升降控制板EK-1AP11-02a TE188-053400DL 继电器板EK-602E-000TET112-02-41-40DL 卫星小车驱动控制板EK-1AP12-02a TE188-054500DL 夹持压力控制板EK-140LV-00TET112-01-73-00DL 卫星小车微控制板EK-537MC/161-14TE188-000706DL激光充电控制EL-T1100.13TE188-053400DL前端模拟量输入板EK-2409LV-02TE188-032400DL 压敏电阻版EK-5587.00TET111-02-20-20DL 五路超高信号选择板EL-5686.02TE188-033100DL五路起道信号选择板EL-T5539.02TE188-033200DL五路拨道信号选择板EL-T5538.02TE188-033300DL四路拨道信号选择板EL-T5589.02TE188-033400DL沉降补偿微控制板EK-537MC-00a/149TE188-053600DL起道模拟控制板EK-3069LV-02a TE188-053200DL电子摆及沉降补偿控制板EK-2351LV TE188-053300DL起拨道补偿微控制板EK-537MC-00a/150TE188-054200DL模拟适配器控制板EL-T5598.002TE188-059300DL拨道模拟控制板EK-2140LV-00TET112-01-65-00DL 拨道参数计算控制板EK-2350LV-02TE188-054300DL激光处理微控制板EK-537MC-00a/166TE188-032200DL激光发射电源充电板EL-T461.07b ZS99-24-30-00-1DL 自动定位控制板EK-1037LV/50-02TE188-053500DL卫星小车横向移动控制板EK-2324LV-02TE188-054400DL 距离脉冲处理板EL-T5596.00a TET111-36-10-00ADL 数字量输入输出板EL-T5201.00d模拟量输入输出板EL-T5202.00b通话放大板EL-T631.01/KM TET112-16-10-00DL 通话切换控制板EL-T5925.02TE188-121000DL延时继电器板(DGS)EL-T5227.00TET111-08-30-10DL 5s延时板(DGS)EL-T5226.00ZS99-03-20-10DL稳定程控主机板(DGS)EK-650PX-00TE188-372200DL 子程序板(DGS)EK-651P-00a TET121-01-41-00DL 程控定时板(DGS)EK-652P-00TET112-01-51-00DL 程控输入输出板(DGS)EK-653P-00TET112-01-33-00DL 程控功率输出板(DGS)EK-654P-00-IR TE188-057200DL40路串行数据输出板EK-432DV-00TE188-055500DL40路串行数据输入板EK-433DV-00TE188-055600DL报警电路板(DGS)EL-T5255.00a TET111-03-30-00DL ±15V,±10V,+5V(DGS)EL-819SV-00TE188-032300DL 稳定微机控制板EK-537MC-00/162TE188-373500DL下沉压力控制板EK-3165LV-02TE188-373200DL 振幅测量板EK-2413LV-002TE188-373300DL振频控制板EK-2682LV-02TE188-373400DL 稳定信号选择板EL-T5875.02TE188-022000DL。
连接技术COM Express载板用户指南说明书
COM Express Carrier User ManualConnect Tech Inc. 42 Arrow Road Guelph, Ontario N1K 1S6 Tel: 519-836-1291Toll: 800-426-8979 (North America only) Fax: 519-836-4878Email: ********************* ***********************Web: CTIM-00312 Revision: 0.01, September 6, 2012Connect Tech COM Express Carrier Boards - User ManualRevision 0.012 Table of ContentsCustomer Support Overview ........................................................................................................................... 4 Contact Information ........................................................................................................................................ 4 Limited Lifetime Warranty ............................................................................................................................. 5 Copyright Notice ............................................................................................................................................. 5 Trademark Acknowledgment .......................................................................................................................... 5 Revision History ............................................................................................................................................. 5 Introduction .. (6)ESD Warning ............................................................................................................................................................ 6 Product Features and Specifications .......................................................................................................................... 7 System Block Diagram . (8)Hardware Description (9)CCG0xx Carrier Board Connector Locations ............................................................................................................ 9 Top Side (9)Bottom Side ..................................................................................................................................................... 10 Jumper and Connector Summary ..................................................................................................................... 11 COM Express Module Interface .............................................................................................................................. 12 Description ...................................................................................................................................................... 12 Connector ..................................................................................................................................................... 12 Module Installation .......................................................................................................................................... 12 Module Fan Power Connector ...................................................................................................................... 12 Power ...................................................................................................................................................................... 13 Description ...................................................................................................................................................... 13 Power Connector .......................................................................................................................................... 13 COM Express Carrier Current Sourcing Capabilities ................................................................................... 13 Current Consumption information................................................................................................................ 14 Power Supply Control .................................................................................................................................. 14 +5V Standby selection ................................................................................................................................. 15 PCI-104 and PC/104 Express Expansion ................................................................................................................ 16 Description ...................................................................................................................................................... 16 PCI-104 and PC/104 Express connectors ..................................................................................................... 16 PCIe/104 Connector ........................................................................................................................................ 16 Video ....................................................................................................................................................................... 17 Description ...................................................................................................................................................... 17 HDMI .............................................................................................................................................................. 17 HDMI Connector.......................................................................................................................................... 17 LVDS Video .................................................................................................................................................... 18 Description ................................................................................................................................................... 18 LVDS Video Header .................................................................................................................................... 18 LVDS Backlight ........................................................................................................................................... 19 LVDS Backlight connector .......................................................................................................................... 19 LVDS Backlight Power Jumper ................................................................................................................... 19 Power for LVDS Panel Circuits ................................................................................................................... 19 LVDS backlight enable polarity ................................................................................................................... 20 VGA ................................................................................................................................................................ 20 VGA Pinouts ................................................................................................................................................ 20 USB 2.0 ................................................................................................................................................................... 21 Description ...................................................................................................................................................... 21 Connector ..................................................................................................................................................... 21 Compact Flash Interface .......................................................................................................................................... 21 Compact Flash Connector ............................................................................................................................ 21 Audio Interface .. (22)Connect Tech COM Express Carrier Boards - User Manual Audio Connectors (22)Audio Selection Jumpers (22)Audio Jumpering Examples (23)SATA (23)Description (23)SATA HDD Connectors (23)SATA HDD Power Connectors (24)mSATA Socket (24)10/100/1000 Ethernet (24)Description (24)10/100/1000 Ethernet RJ Connector (25)Standard Serial (26)Description (26)Serial Connector RS232 (26)Serial Connector RS485 (27)RS485 Control Jumpers (27)RS485 Schematic Snippit (28)Status LEDs (28)J4 Miscellaneous Power Control Jumpers (29)Typical Hardware Installation for +12V power input (30)Software Installation & Configuration (30)Operating System Notes (30)Linux (30)Windows (30)Cables & Interconnect (31)Mechanical (32)Devkit standoffs (32)Devkit (DEV005) parts list (32)Devkit Installation Example (33)Hole Sizes (33)COM Express Carrier Board Dimensions (34)Revision 0.01 3Connect Tech COM Express Carrier Boards - User ManualRevision 0.014 Customer Support OverviewIf you experience difficulties after reading the manual and/or using the product, contact the Connect Tech reseller from which you purchased the product. In most cases the reseller can help you with product installation and difficulties.In the event that the reseller is unable to resolve your problem, our highly qualified support staff can assist you. Our support section is available 24 hours a day, 7 days a week on our website at:/sub/support/support.asp. See the contact information section below for more information on how to contact us directly. Our technical support is always free.Contact InformationMail/Courier Connect Tech Inc. Technical Support 42 Arrow Road Guelph, Ontario Canada N1K 1S6Email/Internet********************************************Telephone/FacsimileTechnical Support representatives are ready to answer your call Monday through Friday, from 8:30 a.m. to 5:00 p.m. Eastern Standard Time. Our numbers for calls are:Toll Free : 800-426-8979 (North America only)Telephone : 519-836-1291 (Live assistance available 8:30 a.m. to 5:00 p.m. EST,Monday to Friday)Facsimile : 519-836-4878 (on-line 24 hours)Connect Tech COM Express Carrier Boards - User Manual Limited Lifetime WarrantyConnect Tech Inc. provides a Lifetime Warranty for all Connect Tech Inc. products. Should this product, in Connect Tech Inc.'s opinion, fail to be in good working order during the warranty period, Connect Tech Inc.will, at its option, repair or replace this product at no charge, provided that the product has not beensubjected to abuse, misuse, accident, disaster or non-Connect Tech Inc. authorized modification or repair.You may obtain warranty service by delivering this product to an authorized Connect Tech Inc. businesspartner or to Connect Tech Inc. along with proof of purchase. Product returned to Connect Tech Inc. must be pre-authorized by Connect Tech Inc. with an RMA (Return Material Authorization) number marked on the outside of the package and sent prepaid, insured and packaged for safe shipment. Connect Tech Inc.will return this product by prepaid ground shipment service.The Connect Tech Inc. Lifetime Warranty is defined as the serviceable life of the product. This is defined as the period during which all components are available. Should the product prove to be irreparable, Connect Tech Inc. reserves the right to substitute an equivalent product if available or to retract Lifetime Warranty if no replacement is available.The above warranty is the only warranty authorized by Connect Tech Inc. Under no circumstances willConnect Tech Inc. be liable in any way for any damages, including any lost profits, lost savings or otherincidental or consequential damages arising out of the use of, or inability to use, such product. Copyright NoticeThe information contained in this document is subject to change without notice. Connect Tech Inc. shallnot be liable for errors contained herein or for incidental consequential damages in connection with thefurnishing, performance, or use of this material. This document contains proprietary information that isprotected by copyright. All rights are reserved. No part of this document may be photocopied, reproduced, or translated to another language without the prior written consent of Connect Tech, Inc.Copyright 2012 by Connect Tech, Inc.Trademark AcknowledgmentConnect Tech, Inc. acknowledges all trademarks, registered trademarks and/or copyrights referred to in this document as the property of their respective owners.Not listing all possible trademarks or copyright acknowledgments does not constitute a lack ofacknowledgment to the rightful owners of the trademarks and copyrights mentioned in this document.Revision 0.01 5Connect Tech COM Express Carrier Boards - User ManualRevision 0.016 IntroductionConnect Tech’s COM Express Carrier Boards are small feature rich, super flexible carrier boards that integrate with any industry standard type II COM Express module. These bus-independent carrier boards offer easy connection to SATA HDD, USB, Ethernet, HDMI Video, LVDS Video, VGA video, RS-232 and RS485 serial.Connect Tech’s COM Express carrier boards are ideal for compact and high performance computingapplications in mobile entertainment, kiosks, digital signage, automation, ROVs and gaming applications.ESD WarningElectronic components and circuits are sensitive toElectroStatic Discharge (ESD). When handling any circuitboard assemblies including Connect Tech COM Express carrier assemblies, it is recommended that ESD safety precautions be observed. ESD safe best practices include, but are not limited to:∙ Leaving circuit boards in their antistatic packaginguntil they are ready to be installed.∙ Using a grounded wrist strap when handling circuitboards, at a minimum you should touch a grounded metal object to dissipate any static charge that may be present on you. ∙ Only handling circuit boards in ESD safe areas, whichmay include ESD floor and table mats, wrist strap stations and ESD safe lab coats.∙ Avoiding handling circuit boards in carpeted areas. ∙ Try to handle the board by the edges, avoiding contactwith components.Connect Tech COM Express Carrier Boards - User Manual Product Features and Specifications* Depends on the peripherals attached, the modules used and the amount of available airflow.Revision 0.01 7Connect Tech COM Express Carrier Boards - User ManualRevision 0.018System Block DiagramVGAIDE Connect Tech COM Express CarrierConnect Tech COM Express Carrier Boards - User ManualRevision 0.01 9Hardware DescriptionCCG0xx Carrier Board Connector Locations Top SideP16 - Audio INP3A - USB ports 1&2P3B - USB ports3&4P11 HDMIP12 - CompactFlash Type IJ8/J9 - AudioP14 - 10/100/1000EthernetP8 - Power SignalP13 - Fan Power J4 - Power Control P6 - ATX Power (option)P9, P10 - SATA HDD PowerP2A, P2B -SATA HDD +12VDC InputJ10 - Audio Sense selection P23 - PC/104 ExpressP17 - mSATAP26 - VGAP24 - RS232Ports 1&2P4 - LVDS VideoJ11 - RS485 ModeJ2 - Panel Backlight SelectionJ1 - Panel VDD SelectionConnect Tech COM Express Carrier Boards - User ManualRevision 0.0110Bottom SideCOM Express ConnectorJumper and Connector SummaryConnector Summary Jumper SummaryCOM Express Module InterfaceDescriptionThe processor and chipset are implemented on the COM Express CPU module, which connects to the COM Express carrier via a Tyco fine pitch stacking connector.Module InstallationEnsure that the Male/Female Hex Standoffs are securely installed and tight. There is a specific technique to installing COM Express modules. It is highly recommended to follow your vendor’s documentation.There are also good instructional videos on YouTube on this subject. You can search for these vid eos with the following string, “installation of a com express module” – enter this into the YouTube search without the quotes!A jumper must be installed on J5 for the fan to operate. The fan speed is fixed by the voltage selected via the jumper.PowerDescriptionThe COM Express carriers are designed to be powered from a single +12V power supply. The carrier board features a 3.5mm screw terminal style connector.The COM Express carrier generates all of the necessary voltages on board.A Panasonic BR1225A/FA Lithium battery provides the VBAT for the COM Express module.COM Express Carrier Current Sourcing CapabilitiesThe following are the maximum current capabilities of the CCG0xx unit. These values cannot be exceeded.Current Consumption informationThe majority of the current consumption is from the COM Express module, the PCI-104 and PC104 Express cards. Other sources of current consumption are USB, SATA HDD drives, etc.The following table can be used to help estimate the total current consumption of you COM Express carrier solution. When building up your COM Express solution you should use your vendor provided datasheets to help create an more precise power estimate.These signals can be used with +12V power supplies that provide Power Good and can utilize a Power Good signal. Power Good is an open drain signal and is pulled up to +5V on the COM Express carrier.PCI-104 and PC/104 Express ExpansionDescriptionDepending on the model, CCG0xx Carrier Boards have PCI-104 expansion or PC/104 Express expansion or both.A PCI-104 interface is provided on the COM Express carrier. The stack up can consist of up to four PCI-104 or PC/104 Express cards in any combination.∙V-I/O on the PCI-104 is set to +3.3V.∙All power rails are sourced by the COM Express Carrier, except for -12V.PCIe/104 ConnectorThe PCIe/104 connector features PCIe/104 Type 1 connections as follows:Descriptionx1 PCIe lanesUSB 2.0 Ports (USB Ports 5 and 6 from module)Misc signals including #Reset and #WakeBank 1 and Bank 2 signals are not connected and are left open.VideoDescriptionThe COM Express carrier features three video outputs, VGA, HDMI and LVDS. The availability of the graphics interfaces depends on the COM Express module selected.The configuration of either interface as the primary or secondary or tertiary display depends on the COM Express module’s BIOS capabilities and settings. Refer to the COM Express module’s documentation for more details.HDMIAn HDMI connector is provided on the COM Express carrier.LVDS VideoDescriptionThe COM Express carrier provides dual 18 or 24 bit LVDS display channels via P4, which are connected directly from the COM Express module. LVDS panel supply power is selected with jumper J1 and backlight power is selected with jumper J2. Both are current limited to 500 mA with Raychem resettable ploy fuses.LVDS BacklightPins 1-2 marked with white lineVGAStandard 15 Pin VGA is available at P26. This header can be adapted to a standard DB15 female the CBG070 cable.USB 2.0DescriptionThe COM Express carrier implements four USB 2.0 connections via two USB connectors. Over current protection and power supply filtering is provided.Only the USB host features of the COM Express specification have been implemented, USB client features are not supported.Compact Flash InterfaceA Type I Compact Flash socket is available. The Compact Flash utilizes the COM Express Module IDE interface. Note that this Compact Flash interface is NOT a hot swappable interface. The Compact Flash is only detected at bootup by the BIOS. The unit should be powered off before installing or removing the Compact Flash card.Audio InterfaceThe COM Expres Carrier features two 3.5mm stereo audio jacks that function as follows:Audio ConnectorsInput Output1.The Microphone input is equipped with a Phantom Power circuit.2.The Headphone output is amplified by the CS4207 Codec.Audio Selection JumpersJ7J6J9J8J10* J10 Provides the CS4207 Audio Codec with the Sense input:The Sense input is used by Audio Codecs to detect the presence of an audio plug being installed into an audio jack, via a switch inside the jack. The Audio jacks on the COM Express carrier do NOT have this switch, so we have provided these jumpers to mimic that function.Not all operating systems require this sense input to be satisfied, for example audio under Ubuntu 10.04 LTS will function fine without the Jumpers, however audio under Windows XP will not.SATADescriptionThe COM Express carrier provides two SATA HDD connections and one mSATA socket. Note the logical order of the SATA ports in the table below.Power connector shown inserted. Pine 1is on the right.The SATA power connectors are fused independently from the main +12V fuse that provides +12V power to the board, i.e. the SATA power connectors are not double fused.10/100/1000 EthernetDescriptionThe CCG0xx COM Express carriers features a standard RJ Jack and magnetics for Ethernet communications. The Ethernet MAC and PHY are located on the COM Express module.Standard SerialDescriptionThe CCG0xx series of COM Express adapters features four serials ports. Port1 and Port2 are standard RS232 and Port3 and Port4 are RS485. The SMSC SCH3114 Super I/O chip is used to facilitate the serial I/O. This chip requires both an LPC bus connection from the module and BIOS support to operate. Ask your module vendor or examine your module documentation to determine of BIOS support is available for the SCH3114.The pinouts are as followssRS485 Control JumpersThe RS485 Control Jumpers are used for implementing the following RS485 modes of operations: ∙½ Duplex Multidrop∙Full Duplex MultidropThe UART RTS signal is used along with the J11 jumpers to facilitate these modes.RS485 Schematic SnippitThe following RS485 schematic snippit is presented to assist in the understanding of the CCG0xx RS485 circuit.Status LEDsLAN Activity100 Mb Connection 1000 Mb Connection +12VSATA Activity Compact Flash Activity +5VJ4 Miscellaneous Power Control JumpersNotes:∙Position A: If ATX power supplies are used, this signal can be used to override the PS_ON signal from the Carrier board and simply force the PS_ON signal to 0V. The ATX supply should switch on as soon as it is powered.∙Position B: Used when operating with a +12V power input. This jumper will route 5V to the POWER_OK pin on the COM Express module.∙Position C: SYSTEM RESET input to the COM Express Module∙Position D: POWER_BUTTON input to the COM Express Module∙Position E: An External Battery could be wired here if the one on the carrier not needed.Typical Hardware Installation for +12V power input1.Ensure all external system power supplies are off.2.Install the COM Express module into P1. Be sure to follow the manufacturer’s direction for properheatsink/heatspreader installation and any other cooling instructions from the manufacturer.3.Verify all jumper settings from the relevant sections, paying special attention the power selection jumpers.Some typical settings are outlined below.4.Install the necessary cables for the application. At a minimum, this would include:a)+12V Power cable to P7b)Video display cable VGA, and/or HDMI.c)Keyboard and mouse via USBd)SATA Power and Signal to SATA HDDFor the relevant cables, see the Cables & Interconnect section of this manual5.Connect the power cable to power supply6.Switch on the power supply. DO NOT power up your COM Express system by plugging in live power. Software Installation & ConfigurationIn general, always refer to the COM Express module’s manual for proper installation of software drivers and configuration software; as well as for appropriate BIOS settings.The following sections provides some specific notes and hints for successful module integrationOperating System NotesLinuxNone at this time.WindowsThe Windows XP Driver for the CS4207 Audio codec may experience issues. Please contact Connect Tech Customer support for more information. The issues involve:∙Microphone input∙Line inputConnect Tech COM Express Carrier Boards - User Manual Audio output should be OK.Cables & InterconnectThe following table summarizes the COM Express carrier’s headers and lists the matching cables included with the optional cable kit CKG007.Cabledrawingsareavailableuponrequest.Sendanemailrequestto:***********************.Revision 0.01 31Connect Tech COM Express Carrier Boards - User ManualRevision 0.0132 MechanicalDevkit standoffsA Devkit, part number DEV005 can be purchased to facilitate bench top development. The Devkit includes screws, standoffs and spacers. See picture below.Connect Tech COM Express Carrier Boards - User ManualDevkit Installation ExampleThree corners of the PCB:∙Qty (6) 20mm Male/Female Hex Stand offs. Stack in pairs to achieve height as needed.∙Qty (3) 5mm M2.5 ScrewsCorner of PCB as seen in picture below:∙Qty (1) 20mm Male/Female Hex Stand offs∙Qty (1) 25mm M2.5 Screw∙Qty (1) 8mm M3 spacer25mm Screw8mm Spacer20mm Male/Female standoffHole SizesRevision 0.01 33COM Express Carrier Board Dimensions。
三星电子A1产品与老型号对比表
参数差异(A1产品特点) 1,分辨率600线 2,A1芯片 3,最低照度:彩色0.3LUX(感光度 OFF ;15 IRE ) 4,菜单设置功能 1,分辨率600线 2,A1芯片 3,最低照度:彩色0.12LUX(感光度 OFF ;15 IRE ) 4,菜单设置功能 5,焦距:2.5~6mm; 2.8~11mm 1,分辨率600线 2,A1芯片 3,最低照度:彩色0.12LUX(感光度 OFF ;15 IRE ) 4,菜单设置功能 5,焦距:2.5~6mm; 2.8~11mm
SCC-C9302P/C9302FP
无 1,分辨率600线 2,A1芯片 3,最低照度:彩色0.3LUX(感光度 OFF ;15 IRE ) ;黑白0.03LUX (感 光度OFF ;15 IRE ) 4,菜单设置功能 5,焦距:3.21~138.5 6,43倍光学;16倍数字放大 1,分辨率600线 2,A1芯片 3,最低照度:彩色0.3LUX(感光度 OFF ;15 IRE ) ;黑白0.03LUX (感 光度OFF ;15 IRE ) 4,菜单设置功能 5,焦距:3.21~138.5 6,43倍光学;16倍数字放大 1,分辨率600线 2,A1芯片 3,最低照度:彩色0.3LUX(感光度 OFF ;15 IRE ) ;黑白0.03LUX (感 光度OFF ;15 IRE ) 4,菜单设置功能 5,焦距:3.21~138.5 6,43倍光学;16倍数字放大 1,分辨率600线 2,A1芯片 3,最低照度:彩色0.3LUX(感光度 OFF ;15 IRE ) ;黑白0.03LUX (感 光度OFF ;15 IRE ) 4,菜单设置功能 5,焦距:3.21~138.5 6,43倍光学;16倍数字放大
SCC-641P/643AP /C6403P/C6433P
DP1903 最具性价比芯片
特性描述
DP1903是单线三通道RGB LED驱动芯片,内部集成有MCU数字接口、数据锁存器、 LED 高压驱 动等电路 。 通过外围MCU控制实现该芯片的单独辉度级联控、制实现户外大屏的彩色点阵发光控制。
特性说明
输出端口耐压17 V 芯片内置稳压管,电源端需串电阻到IC VDD脚 辉度调节电路(256级辉度可调) 内置双RC振荡,并根据数据线上信号进行时钟同步,在接受完本单元的数据后能自动将后续数据进行 整形转发 内置上电复位电路 PWM控制端能够实现256级调节,扫描频率不低于400 Hz / s 单线串行级联接口,内设GAMMA校正。 线性传输时,可无限级联 任意两点传输距离超过10米而无需增加任何电路 当刷新速率30帧 / 秒时,低速模式级联数不小于512点,高速模式不小于1024点 数据发送速度可达400 Kbps与800 Kbps两种模式 采用预置恒流模式,并根据红灯发光强度弱的原理,使OUTR输出口的电流略大于OUTG与OUTB,白光效 果更佳。 HBM ESD > 6KV
5
DP1903
典型应用电路
(1)芯片典型应用参数
VIN
RL RL RL RIN CIN 1 OUTR 2 OUTG 3 OUTB 4 GND VDD 8
LEDB
LEDG
LEDR
DP1903
SET 7 DIN 6 DO 5 R SER
DATA
上图的 DP1903 典型应用电路参数包含电源输入电压 VIN, 限流电阻 RIN, 芯片 VDD 稳压电容 CIN 和 R/G/B LED 限流电阻 RIN。 芯片电源电压 VDD: VDD=VIN-(IDD+IIN)*RIN 其中 IIN 是芯片内部稳压电路的工作电流, IDD 是芯片静态电流 (稳压电路电流除外) , RIN 阻值必须保证 VDD > 4V。 当系统输入电压 VIN 低于 5.2V 时,建议芯片 VDD 端口串接不大于 50Ω 的电阻,防止电源电压波动。 VIN = 12V,建议 RIN= 1KΩ;VIN = 24V,建议 RIN = 3 KΩ,RIN 电阻越大,系统功耗越低,但系统抗干扰能力弱; RIN 电阻越小,系统功耗越大,工作温度较高,设计时需根据系统应用环境折衷选择电阻 RIN。VIN 与 RIN 的关系 如下表所示: VIN RL 5V 33 6V 100 9V 470 12V 1K 15V 1.5K 18V 2K 24V 3K
康普型号
SC多模连接器 72口光纤配线架 机架式光纤配线架 机架式光纤配线架 600A系列支架 STII单模光纤连接器 6口ST耦合器面板 (不含耦合器,12个/ 包) ST单模耦合器 24口LC双工空面板 光纤夹 固线器 光线衰减测试仪 光纤耗材 光纤耗材 788H1替换头 五对打线工具 光纤耗材 挑线勾 单对打线工具(含手 柄及刀头) 单对打线工具手柄 单对打线工具刀头 光纤耗材 小型光纤工具( ST SC LC 多模/单模连 接) 光纤耗材 光纤工具(STⅡ,ST Ⅱ+,SC连接) 环氧胶水 OSP缓冲套管零件箱 (光纤消耗品附件) 光纤梳理器
货物名称 3类25对主干电缆 3类50对主干电缆 3类100对主干电缆 超五类线 5类25对主干电缆 六类线 1对普通跳线 2对普通跳线 110五类2芯跳线 5FT,(10条/包) 110五类2芯跳线 7FT,(10条/包) 110五类2芯跳线 9FT,(10条/包) 110五类2芯跳线 15FT,(10条/包) 110五类4芯跳线 5FT,(10条/包) 110五类4芯跳线 7FT,(10条/包) 110五类8芯跳线 7FT,(10条/包) 110五类8芯跳线 9FT,(10条/包) 110千兆8芯跳线 5FT 110千兆8芯跳线 7FT 110千兆8芯跳线 9FT 六类跳线 7FT 六类跳线 5FT 六类跳线 9FT 六类跳线 15FT 110-4对连接块(10个 /包) 110-5对连接块(10个 /包) 透明标签固定器(6 个/包) 带腿过线槽 P型300对跳线架 P型900对跳线架 100对有腿配线架 300对有腿配线架 100对有腿配线架(不 含配件) 100对无腿配线架 900对垂直过线槽 300对垂直过线槽 110安装托架 过线槽(带腿)
单 位 轴 轴 轴 箱 轴 箱 轴 轴 条 条 条 条 条 条 条 条 条 条 条 条 条 条 条 包 包 包 个 个 个 个 个 个 个 个 个 个 个
铝合金牌号对照
ISO(欧盟)
Al 99.5 Al 99.6 Al 99.7 Al 99.0Cu Al 99.0 E-Al99.5 E-Al99.7 Al 99.3
日本
A1050 A1060 A1070
印度
19500 19600 19700
俄罗斯
A6 A7
EN(欧洲)
EN AW-1050A/Al99.5 EN AW-1060/Al99.6 EN AW-1070A/Al99.7 EN AW-1100/Al99.0Cu EN AW-1200/Al99.0 EN AW-1350/E-Al99.5 EN AW-1370/E-Al99.7 EN AW-1050A/Al99.5
2117(A-U2G)
1199/A91199 1098/A91098 1185/来自91185 1350A 2117
EN AW-2024/AlCu4Mg1 EN AW-2014/AlCu4Mg EN AW-2019/AlCu6Mn
AlCuMg1/3.1325 AlCuMg2/3.1355 AlCuSiMn/3.1255
A2030 22588 3A21(LF21) 3003 3004 3005 3103 3105 AlMn1Cu AlMn1Cu AlMn1Mg1 AlMn1Mg1.5 AlMn1 AlMn0.5Mg0.5 A2618 A3003 A3003 A3004 A3005 A3103 A3105 AK4/1140 AMц /1400 AMц /1400 AMц 2/1511 MM/1403
AlCuMg2/3.1355 AlCu2.5Mg0.5/3.1305
2024(A-U4G1) 2117(A-U2G) 2218(A-U4N)
AlCu6Mn
A2218 A2219 A2618
Epi-ReadyPolishedAlNSubstrate-gmsystems
Polycrystalline Aluminum Nitride (AlN) SubstrateProduct Data SheetTriangle Ceramics991 Aviation Pkwy, Suite 800Morrisville, NC 27560Tel: +1 919 415 1546**************************Product OverviewTriangle Ceramics’polycrystalline aluminum nitride substrates are semiconductor process ready with shape specifications meeting SEMI specifications for wafer processing. Designed for high volume cassette-to-cassette wafer fab operations, the substrates are currently available in 150 mm and 200 mm diameters. In addition, we have the capability to manufacture 300 mm and 450 mm diameter material (contact factory).Our unique patent-pending manufacturing process enables large diameter, low cost substrates with a shape and finish ready for semiconductor processing. Typical manufacturing processes used for poly-AlN cannot consistently meet the SEMI shape and surface finish requirements for volume wafer production. Semiconductor applications that require matching thermal expansion coefficient, and require a high thermal conductivity, engineered poly-AlN wafers are a cost effective solution. Compared to sapphire substrates, the CTE match with GaN is improved by 10X. This will yield longer life and improved performance due to lower dislocation density.Standard material is double side polished (single-side and unpolished wafers are also available), and the standard thickness for 150 mm wafers is 635 +/- 15 um. Thicker or thinner wafers can also be available.ApplicationsLayer Transfer:With much of today’s research for LED’s, power conversion devices, and other devices aimed at advanced performance with improved substrates, poly-AlN offers an excellent platform for layer transfer technology where cost, device performance, and thermal management need to be critically balanced to lead the industry.Mechanical wafers: Polycrystalline AlN is well suited for mec hanical wafer applications as a lower cost substitute for sapphire, or where a thermal conductivity higher than sapphire would help improve device performance and cost. With a 200 mm and beyond wafer diameter, polycrystalline AlN can enable large diameter silicon processing where sapphire cannot go.Handle Wafers:With an electrical resistivity of over 1E14 Ohm-cm, polycrystalline AlN is also well suited as a handle wafer in SOI and SOS wafer applications, enabling CMOS and MEMS technologies to experience the cost and capacity benefits of 200 mm and beyond processing.Heat Spreaders: For device manufacturing where thermal management plays a pivotal role in device performance, poly-AlN is an ideal material for eliminating heat. With a thermal conductivity several times higher than sapphire, AlN can be used to transport thermal energy away from devices quickly.Selection of AlN Materials OfferedHP-AlN: High Purity Aluminum Nitride- this material contains no sintering aid and generally has impurities (excluding oxygen) in the PPM range. This is commonly used in semiconductor and military applications where purity is critical.HR-AlN: High Reflectivity (white) Aluminum Nitride- this material is very white, similar to alumina, and is used for optical applications where thermal conductivity needs to be much higher than alumina and material is required to be electrically insulating.ZP-AlN: Zero Porosity Aluminum Nitride- while most available AlN is considered ‘fully dense’, SEM and AFM can reveal porosity in the 2+ um range. Our Zero Porosity AlN material has almost no pores >1 um. This material is typically used for semiconductor (specifically Silicon) layer transfer applications where surface planarity, pitting, and smoothness are critical.HK-AlN: High Thermal Conductivity Aluminum Nitride- this is 180+ W/mK material typically used for thermal management.200 mm Wafer SpecificationsImage of 150 mm polished poly-AlN double side polished wafer Image of 200 mm double side polished poly-AlN wafersOptical Images of Grain StructureSEM ImageAFM Image。
3-Phase Switched PDU 产品介绍说明书
27.7kW 3-Phase Switched PDU - 12 C13 & 12 C19 Outlets, IEC 309 63A Red, 0U, Outlet Monitoring, TAAMODEL NUMBER:PDU3XEVSR6G63A3-phase switched PDU distributes, monitors and manages power in a medium/large data center or network installation.Features3-Phase PDU Distributes, Monitors and Manages Network-Grade PowerRecommended for data centers, server rooms and high-density network closets, this switched PDU provides advanced network control and remote power monitoring with the ability to turn on, turn off, reboot or lock out power to each outlet. You can more efficiently manage network power consumption and remotely reboot locked network items without having to visit the site. Reducing the number of on-site visits can help lower the cost of data center maintenance, thus lowering the 0U PDU’s total cost of ownership.24 Outlets Dispense AC Power to Connected EquipmentDuring normal operation, 24 individually controllable outlets—12 C13 and 12 C19—in six separately breakered load banks distribute AC power to rack equipment. Each 220/230V outlet is accompanied by an LED that illuminates when the outlet is ramped up and ready to be used. The outlets and banks can be individually monitored to ensure proper load balance and prevent downtime. Plug-lock insert sleeves are included to prevent connected cables from becoming accidentally dislodged.Built-In LX Platform Network Management Card Allows Remote Access 24/7The Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100/1000 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. The 0U PDU can receive IP address assignments via DHCP server (automatic) or static (manual) method.Color Touchscreen LCD Offers Important Data at a GlanceAn easy-to-navigate color touchscreen LCD reports network data, input current level per phase, and output current per load bank and per outlet with ±1% billing-grade accuracy. It also generates a unique QR code to allow read-only access to the 3-phase PDU via mobile device. If an EnviroSense2 module is connected to the PDU, the LCD also displays its status and environmental data, such as temperature and humidity.Easy to Install Vertically in an EIA-Standard 19 in. Rack Highlights12 C13 and 12 C19 220/230Voutlets distribute AC power toconnected equipmentqBuilt-in Java-free HTML5-based LX Platform interface allows you 24/7 remote accessqRemote power monitoring andcontrol reduces on-site visitsand maintenance costsq6 ft. cord with IEC 309 63A Red(3P+N+E) 3-phase inputconnects to AC power sourceqColor touchscreen LCD provides current levels, environmentaldata and network infoqApplicationsPower mission-critical rackequipment in a data center,computer room or high-densitynetwork closetqMonitor power loads fromvarious computers, switches,servers and other networkingequipmentqMaintain a computer network ina government, commercial orindustrial facilityqManage multiple rack devicesby rebooting or shutting downindividual outlets as neededqPackage IncludesPDU3XEVSR6G63A 27.7kW 3-Phase Switched PDUqBuilt-in LX Platform interfaceqConfiguration cableq(24) Plug-lock insert sleevesqSpecificationsThe 70-inch 0U PDU mounts vertically using the pre-installed toolless mounting buttons or the included brackets. Spare buttons are also included. Use the included PDUMVROTATEBRKT kit to install the PDU with outlets facing the rear for better airflow or equipment access. A six-foot cord with IEC 309 63A Red (3P+N+E) 380/400V 3-phase input connects the switched PDU to a compatible AC power source,generator or protected UPS.TAA-Compliant for GSA Schedule PurchasesThe PDU3XEVSR6G63A is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.2-Year WarrantyThe PDU3XEVSR6G63A is backed by a 2-year warranty, ensuring reliability and performance.Rack-mounting hardware qSpare mounting buttons qPDUMVROTATEBRKT mounting bracket accessoryqOwner’s manualq© 2019 Tripp Lite. All rights reserved. All product and company names are trademarks or registered trademarks of their respective holders. Use of them does not imply any affiliation with or endorsement by them. Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice. Tripp Lite uses primary and third-party agencies to test its products for compliance with standards. See a list of Tripp Lite's testing agencies:https:///products/product-certification-agencies。