N700说明书

合集下载

NOXMAT 700 CLD NO NOx数字分析器说明书

NOXMAT 700 CLD NO NOx数字分析器说明书

Features• Measures from ppb to 3,000 ppm Full Scale (NO/Nox)• Four User Programmable Ranges from 0-1 ppm to 0-3,000 ppm•FastResponseTime•AutoRanging•AutoCalibration • Output Options: Analog (User Scalable), Digital (RS232)including AK Protocol & TCP/IP• Displays & Outputs: NO/NOx/NO2 with Adjustable Time &Hold, Diagnostics, Alarms & Preventative Maintenance• Remote Monitoring and Control• Electronic Sample & Ozone Flow Control /analyticalproductsAnalytical Products and SolutionsNOXMAT 700Accurate, Precise, DependableDescriptionThe NOXMAT Model 700 CLD NO/NOx digital analyzer isdesigned around a state-of-the-art 16-bit microprocessor, with16 digital inputs, 16 digital outputs, 16 analog inputs and 4analog outputs. The analyzer can be manually operated fromthe keypad or remotely via TCP/IP, RS- 232C communicationsand discrete inputs.The analyzer display includes screen presentation of all analyzeralarms. Four levels of password protection are provided. Forprecision measurements, the analyzer’s accuracy is increased byentering calibration curve fit polynomials.Automatic calibration may be activated locally or remotely andincludes auto cal via preset times. The analyzer may also displayNO, NOx and NO2 via selectable time and hold commands.For more information, please contact:Siemens Industry, Inc.5980 West Sam Houston Parkway North Suite 500Houston, TX 77041Phone: 713-939-7400Email:*************************************************************Method of OperationThe NOXMAT 700 CLD Analyzer utilizes the principle ofchemiluminescence for analyzing the NO or NOx concentration within a gaseous sample. In the NO mode, the method is based upon the chemiluminescent reaction between ozone and nitric oxide (NO) yielding nitrogen dioxide (NO 2) and oxygen. This reaction produces light which has an intensity proportional to the mass flow rate of NO into the reaction chamber. The light is measured by means of a photodiode and associatedamplification electronics. In the NOx mode, NO plus NO 2 is determined as above, however, the sample is first routed through the internal NO 2 in the sample to NO. The resultant reaction is then directly proportional to the total concentration of NOx. Local operation is simplified using the 20 button alphanumeric keypad with data presented on a back lit LCD display. All local operations may be performed remote via RS-232 and/or TCP/IP.Applications • Stack Gases (C E M) • Scrubber E fficiency • Turbine/Generator Feedback Control • Process Chemical Gas Analysis • Personnel Safety • Power Plant Stack De-Nitrification • Vehicle EmissionsSpecificationsDetector: Chemiluminescence (CLD) Photodiode (thermally stabilized with Peltier Cooler) NO/NOx RANGES: 0-1 * to 3,000 ppm NO or NOx (Four user programmable ranges) (Higher ranges available upon request)Response Time: T90 < 2 Seconds to 60 Seconds Adjustable Resolution: 10 ppb NO/NOx (Displays 5 significant digits)Repeatability: Better than 0.5% of Full Scale Linearity: Better than 0.5% of Full ScaleNoise*: Less than 1 % of Full Scale (*1.5% @ 0-1 ppm Full Scale)Zero & Span Drift: Less than 1 % of Full Scale per 24 Hours Zero & Span Adjustment: Via front panel, TCP/IP or RS-232NH 3, HCN & SO 2 Effect: Not detectable with 100 ppm CO 2 Effect: Less than 1 % with 10% CO 2H 2O Effect: Less than 1 % with 1 % H 2OSample Gas Pressure: 8-25 psig (Standard model)Sample Flow Rate: 1.5 to 2.0 LPM (Consult factory for other flow rates)Converter:****************************>98%efficiency Ozonator: Ultraviolet LampAir Or O 2 Requirements: Less than 0.01 ppm NOx at 350 cc/Min. @ 25 psig (Dew Point < -35°C)NO/NOx Control: Manual/Remote/Auto Cycle (Remote NOx mode by dry contact closure)Outputs Available: TCP/IP, RS232, Four Scalable Analog 0- 10 V/4-20 mADiscrete Alarms: (Local & Remote Adjustable) General Fault! TTL Logic (Ground True) Calibration Failure/ TTL Logic (Ground True) High Concentration (2 each)/ TTL Logic (Ground True)Digital Diagnostics: Control Voltages, Temperatures, Pressures, Flow ParametersKeypad Displays: Factory Settings,TCP/IP Address, Passwords (4), Scalable Analog Output Voltages, Full Scale Range Select, Auto Cal Times Special Features: Calculated NO 2 derived from NOx converter efficiency, Auto Ranging, Auto Calibration (adjustable through internal clock) Less than 3 cc Gold Plated Reaction Chamber Display: 3” x 5” Back lit LCD Sample Temperature: Up to 50.C Noncondensing Ambient Temperature: 5 to 40.CAmbient Humidity: Less than 90% RH Noncondensing Warm-Up Time: 1 Hour (Typical)Fittings: 1/4 Inch TubePower Requirements: 115/230 (:t100;0) VAC; 50/60 Hz; 200 Watts (350 watts with pump)Dimensions: 5 1/4 H x 19 W x 17 D (Inches) - short case Weight: 45 Pounds。

电子路线GAS 电子炉 N700 产品说明书

电子路线GAS 电子炉 N700 产品说明书
0530843301 47 0214584201 49 0522883603
0522883604 50 0522882700 51 0533825300 52 0533825400 54 0529835403
0529835404 55 0516860700 59 0140088006 61 0560840300
KNOB GAS TAP
MANOPOLA COMMUTATORE
KNOB, SWITCH
MANOPOLA TERMOSTATO
KNOB, THERMOSTAT
MOLLETTA
SPRING
RONDELLA GUARNIZIONE MANOPOLA
WASHER GASKET FOR KNOB
MOLLA PER MARCHIO MANIGLIA FORNO
0548858100 0548862701 13 0214590701 14 0527850500 16 0548859700 0548860700 0548860800 17 0218912211 17a 0541813800 18 0543815000
20 0518801801 21 0831825200 22 0529837000 23 0560839601 24 0522882800 25 0835848100 26 0835856900 28 0508898900
0C0218 0C0219
* 0C4672 052725 0C1996 0C2016 0C0177 0C0138 0C1280 0C0139
* 0C0201
* * * 066823 * * * * * 0C0165 0C5244 0C0137 0L0113 0C0261
FACCIATA FORNO 800mm FACCIATA FORNO 1200mm ISOLANTE DX E SX FORNO GRIGLIA CAMINO COPRICERNIERA PORTA SINISTRA MANIGLIA SINISTRA CONTROPORTA CERNIERA PERNO PORTA CERNIERA FONDO ARMADIETTO MAGNETE CELLA ARMADIETTO FONDO CUCINA GAS 800mm FONDO CUCINA GAS 1200mm MOLLA PER BULBO INVOLUCRO FORNO INVOLUCRO FORNO SCHIENALE FORNO ANTERIORE CAMINO FORNO POST. CAMINO FORNO SUPPORTO CERNIERA SUPPORTO CERNIERA PIASTRA GIUNZIONE POST. GUARNIZIONE CRUSCOTTO ISOLAMENTO ANTERIORE CELLA

ABB VSN700数据日志器产品介绍说明书

ABB VSN700数据日志器产品介绍说明书

ABB monitoring and communicationsVSN700 Data LoggerThe high-performance VSN700 Data Logger provides simple and quick commissioning with device discovery and automatic IP addressing as wellas remote management features.This SunSpec Compliant TM datalogger records data and events from inverters, energy meters, weather stations, and other photovoltaicplant devices. It acts as an Internet gateway to send the data securelyand reliably to the Aurora Vision®Plant Management Platform for performance monitoring, condition monitoring, and data reporting.The VSN700 Data Logger is also availa-ble integrated in turnkey solutions, such as VSN730 System Monitor.Three performance levels offermaximum flexibility.The VSN700 Data Logger is availablein three performance levels to fitvirtually any budget and functionalityrequirements:VSN700-01 Data Logger is available toresidential customers who only need tomonitor five (5) single-phase inverters.VSN700-03 Data Logger is a cost-optimized logger for small commercialinstallations up to ten (10) single orthree-phase string inverters and oneweather station (VSN800).VSN700-05 Data Logger providesboth customer data managementand inverter command, and controlfor commercial and utility PV systemoperation, as well as SCADAintegration.Highlights:All VSN700 Data Logger modelsinclude:−Data management system with serialand Ethernet ports for data andevent logging−Quick installation and fast plug-n-play commissioning with devicediscovery mechanism−Network provisioning with dynamic IPaddressing (DHCP client and server)−Reliable and secure transmission ofoperational data to Aurora Vision®Plant Management Platform−Remote configuration andmanagement capabilities, includingfirmware upgrades over the Internetusing Aurora Vision® Plant PortfolioManager−Simple end-user UI using AuroraVision® Plant Viewer2 ABB solar inverters | Datasheet for VSN700 Data LoggerTechnical data and typesAdditional highlights:VSN700-05 Data Logger (Max) includes the following additional functionality: −No software limitation on number of devices logged−Modbus TCP server using SunSpec Alliance compliant Modbus maps for easy SCADA system integration, data collection, and inverter command execution−Support for most ABB inverters, meters, smart combiners andweather stations (see VSN700 DataLogger model comparison table)VSN700 Data LoggerVSN700 Data Logger model comparisonDatasheet for VSN700 Data | ABB solar inverters 3Commercial and utility application with VSN700-05Plant Portfolio Manager Plant ViewerScadaString invertersVSN700-05Weather StationMODBUS TCP or IPPlant ViewerVSN700-01B C D .00387 A B B -V S N 700 E N R E V C 3.01.2016Support and serviceABB supports its customers with a dedicated, global service organization in more than 60 countries, with strong regional and national technical partner networks providing a complete range of life cycle services.For more information please contact your local ABB representative or visit:/solarinverters © Copyright 2015 ABB. All rights reserved. Specifications subject to change without notice.。

N720用户手册(Linux)说明书

N720用户手册(Linux)说明书

N720 User ManualLinuxVersion 1.0Copyright © Neoway Technology Co., Ltd 2017. All rights reserved.No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Shenzhen Neoway Technology Co., Ltd.is the trademark of Neoway Technology Co., Ltd.All other trademarks and trade names mentioned in this document are the property of their respective holders.NoticeThis document provides guide for users to use the N720.This document is intended for system engineers (SEs), development engineers, and test engineers.The information in this document is subject to change without notice due to product version update or other reasons.Every effort has been made in preparation of this document to ensure accuracy of the contents, but all statements, information, and recommendations in this document do not constitute a warranty of any kind, express or implied.Neoway provides customers complete technical support. If you have any question, please contact your account manager or email to the following email addresses:**********************************Website: Contents1 Port Mapping (2)2 Loading USB Driver (3)2.1 Querying Devices (3)2.2 Adding VID and PID (3)2.3 Configuring Kernel (3)2.4 Testing AT Commands (4)3 Establishing Connection Using pppd (8)3.1 Checking Device (8)3.2 Adding VID and PID (8)3.3 Adding pppd Driver to Kernel (8)3.4 Dialing up (9)3.5 Test and Disconnection (12)3.5.1 Testing the Connection (12)3.5.2 Disconnecting the Connection (12)4 Establishing Connection Using RMNET (14)4.1 Checking Device (14)4.2 Adding VID and PID (14)4.3 Adding GobiNet Driver to Kernel (14)4.4 Configuring Before Dialup (16)4.5 Dialing Up Using RMNET (17)4.6 Test and Disconnection (18)4.6.1 Testing the Connection (18)4.6.2 Disconnecting the Connection (19)5 Establishing Connection Using RNDIS (20)5.1 Checking Device (20)5.2 Adding VID and PID (20)5.3 Adding RNDIS Driver to Kernel (20)5.4 Dialing Up Using RNDIS (21)5.5 Test and Disconnection (22)5.5.1 Testing the Connection (22)5.5.2 Disconnecting the Connection (23)6 Establishing Connection Using ECM (24)6.1 Checking Device (24)6.2 Adding VID and PID (24)6.3 Adding ECM Driver to Kernel (24)6.4 Dialing Up Using RNDIS (26)6.5 Test and Disconnection (27)6.5.1 Testing the Connection (27)6.5.2 Disconnecting the Connection (27)7 FAQ (28)About This DocumentThis document provides guidance about how to add the USB driver of the N720 and how to share the Internet access of an N720 on Linux.1 Port MappingN720 supports network share via pppd, RNDIS, ECM, and RMNET. Each mode corresponds to different VID and PID. Developers can switch the mode by sending AT command (AT+NETSHAREMODE). The mapping between the ports and share modes is shown as follows:●VID: 0x2949 PID: 0x8241 Support pppd/RNDIS dialupDefault USB composition: RNDIS(00)+MODEM(02)+TTY(03 NMEA)+TTY(04 AT)+Diag(05)2 Loading USB Driver2.1 Querying DevicesExecute lsusb to check whether USB devices are displayed. Ensure that N720 is identified.In the figure above, the VID of N720 is 0x2949 and the PID of N720 is 0x8241.If the host does not identify N720, check whether N720 is connected to the host, whether it ispowered up and started, or whether it is connected to the host through USB.2.2 Adding VID and PIDIn kernel/drivers/usb/serial/option.c, add VID:0x2949 PID:0x8241 to option_ids.2.3 Configuring KernelOn Linux, the USB-to-Serial driver is widely used. Before adding the driver, configure the Linux kernel following steps below:1.Navigate to the kernel directory.2.Execute make menuconfig.The kernel configuration is displayed.3.Configure kernel.ATE //Enable terminal display.OKAT+CGMR //Query software version.+CGMR: N720_D0B0CM_BZ_V003AT+CPIN? //Query PIN code.+CPIN: READYAT+CSQ //Query signal.+CSQ: 31,99 //RSSI: 31; bit error rate: 99AT+CREG? //Query the registration status of the CS domain (SMS and voice call service) +CREG: 0,1AT+CGREG? ////Query the registration status of the PS domain (data service)+CGREG: 0,1AT$MYSYSINFO //Query the mode of the network registered.$MYSYSINFO: 4,03 //Registered China Telecom 4G network.AT+COPS? //Query carrier's information.+COPS: 0,0,"CHINA TELECOM",7 //China Telecom●Testing AT commands in CLIecho -e "AT+CSQ\r\n" > /dev/ttyUSB2;cat /dev/ttyUSB2●Only modem port or AT port can be used to send AT commands.●If any messages are displayed to ask for permission, modify the permission for the ttyUSB port.●If the AT command contains any special character, add \ before it.3 Establishing Connection Using pppdAll three configuration modes of N720 VID:0x2949 PID:0x8241, VID:0x2949 PID:0x8242, andVID:0x2949 PID:0x8243 support network dialup using pppd. The following sections describe how to dial up and establish a PPP connection using pppd.3.1 Checking DeviceExecute lsusb to check if N720 is identified.N720 has been identified with a VID of 0x2949 and a PID of 0x8241.3.2 Adding VID and PIDIn kernel/drivers/usb/serial/option.c, add VID:0x2949 PID:0x8241 to option_ids.3.3 Adding pppd Driver to Kernel1.Navigate to the kernel directory and execute make menuconfig.The kernel configuration GUI is displayed.2.Configure kernel.Select Device Drivers > Network device support > ppp options.pppd call gpra-dial: executed to dial up to set up a connection.gprs-chat: contains the AT commands and response to them between chat and the GPRS module.4.Check the carrier information and network mode, and the set APN.AT+CGDCONT=1,”IP”,”APN_XXX”OKXXX indicates the carrier APN. For example,2G, 3G, and 4G of China Mobile: CMNET2G, 3G , and 4G of China Unicom: 3GNET 2G and 3G of China Telecom: CTNET 4G of China Telecom: CTLTEFor other networks, consult your carriers.●The module will set APN based on current network mode if developers do not set it before PPPD dialup. If the APN is set before pppd dialup, the module will dial up the network using the set APN.Set the modem port as the dialup port. Otherwise, the module cannot dial up a network successfully.−/etc/ppp/gprs-chat3.5 Test and Disconnection3.5.1 Testing the ConnectionInput ifconfig to check the IP address of ppp0.Ping a valid IP address to check if the host is connected to the Internet.Ping a valid domain name.If a website can be reached through IP address but cannot be reached through its domain name, add DNS(114.114.114.114) to /etc/resolv.conf.3.5.2 Disconnecting the Connection1.Execute the ppp-off script.2.Run the # killall pppd command.4 Establishing Connection Using RMNET N720 supports dialup and connection setup using RMNET with a VID of 0x2949 and a PID of 0x8243. GobitNet driver is used to interact with N720 on the Linux for network dialup through RMNET. GobitNet will create a network device called ethX and a /dev/qcqmiX character device. After the two devices are created and N720 can register a network, developers can dial up the network using the dialup program.Send AT+NETSHAREMODE=2 to N720 to switch the configuration if the PID is not 0x8243. 4.1 Checking DeviceExecute lsusb to check if N720 is identified.N720 has been identified with a VID of 0x2949 and a PID of 0x8243.4.2 Adding VID and PIDIn kernel/drivers/usb/serial/option.c, add VID:0x2949 PID:0x8243 to option_ids.4.3 Adding GobiNet Driver to Kernel1.Copy the GobiNet driver code (NWY-GobiNet/src/) to kernel/drivers/net/usb.2.Add config USB_GOBI_NET to kernel/drivers/net/usb/Kconfig.config USB_GOBI_NETtristate "Gobi USB Net driver for NWY module"helpSupport NWY module.A modem manager with support for GobiNet is recommended.3.Modify kernel/drivers/net/usb/Makefile to ensure that GobiNet module can be compiled.obj-$(CONFIG_USB_GOBI_NET) += GobiNet.oGobiNet-objs:=GobiUSBNet.o QMIDevice.o QMI.o4.Configure kernel. Select the GobiNet option and save the settings.Device Drivers --->[*]Network device support --->[*]USB Network Adapters --->[M]Gobi USB driver for NWY modulepile the kernel again and burn the kernel to the host.6.Power up the host and check whether the driver is loaded successfully.Input lsusb –t to check whether the driver is identified.Input ifconfig to check NIC information.If a new NIC, e.g. eth1, is displayed, the driver is loaded successfully.7.Check if qcqmi1 is created successfully.4.4 Configuring Before DialupTo dial up and set a connection through RMNET on Linux, developers need to use Neoway dialup program.Execute make under the NWY-CM-code/src directory to obtain the NWY-CM program. Assign the NWY-CM program execution permission.Input NWY-CM-h to check Help.AT+CPIN?AT+CSQAT+CREG?AT+CGREG?AT$MYSYSINFO2.Execute NWY0CM to dial up and establish a network connection.4.6 Test and Disconnection4.6.1 Testing the ConnectionInput ifconfig to check the IP address of eth1.Ping a valid IP address to check if the host is connected to the Internet.Ping a valid domain name.4.6.2 Disconnecting the Connection Run the killall NWY-CM command.5 Establishing Connection Using RNDISN720 supports dialup and connection setup using RMNET with a VID of 0x2949 and a PID of 0x8241.Send AT+NETSHAREMODE=2 to N720 to switch the configuration if t1.1he PID is not 0x8241.pile the kernel again and burn the kernel to the host.4.Power up the host and check whether the usb0 is displayed.5.Query whether the RNDIS driver is loaded successfully.Input lsusb –t.Input lsmod | grep rndis.5.4 Dialing Up Using RNDIS1.Run the following commands to confirm that N720 registered a network.AT+CPIN? //Query SIM card status.AT+CSQ //Query signal.AT+CREG?AT+CGREG?AT$MYSYSINFO //Query network mode.2.Send A T commands to dial up.After dialing up and establishing a connection using RNDIS, the module cannot dial up or establish a connection using pppd anymore.5.5 Test and Disconnection5.5.1 Testing the ConnectionInput ifconfig to check the IP address of usb0.Ping a valid website to see if the connection works properly. 5.5.2 Disconnecting the Connection Send AT+NETSHAREACT=1,0,0 to disconnect the connection.6 Establishing Connection Using ECMN720 supports dialup and connection setup using ECM with a VID of 0x2949 and a PID of 0x8242.Send AT+NETSHAREMODE=2 to N720 to switch the configuration if t1.1he PID is not 0x8242.6.1 Checking DeviceExecute lsusb to check if N720 is identified.N720 has been identified with a VID of 0x2949 and a PID of 0x8242.6.2 Adding VID and PIDIn kernel/drivers/usb/serial/option.c, add VID:0x2949 PID:0x8242 to option_ids.6.3 Adding ECM Driver to Kernel1.Navigate to kernel and execute make menuconfig.2.Configure kernel. Select RNDIIS option and save the settings.3. Compile the kernel again and burn the kernel to the host.4. Power up the host and check whether the usb0 is displayed.5. Query whether the ECM driver is loaded successfully.Input lsusb –t .Input lsmod | grep cdc .6.4 Dialing Up Using RNDIS1.Run the following commands to confirm that N720 registered a network.AT+CPIN? //Query SIM card status.AT+CSQ //Query signal.AT+CREG?AT+CGREG?AT$MYSYSINFO //Query network mode.2.Send A T commands to dial up.After dialing up and establishing a connection using ECM, the module cannot dial up or establish a connection using pppd anymore.6.5 Test and Disconnection6.5.1 Testing the ConnectionInput ifconfig to check the IP address of usb0.Ping a valid website to see if the connection works properly. 6.5.2 Disconnecting the Connection Send AT+NETSHAREACT=1,0,0 to disconnect the connection.7 FAQQ: Why I cannot find the USB ports after adding the VID and PID of the module to the kernel and executing ls /dev/ttyUSB*?A:1.Check if the module is powered up and connected through USB.Input lsusb or dmesg to check the USB device information.2.Check the VID and PID are added correctly.3.Check if the modifications are compiled by the system.You can find the USB ports by inputting ls /dev/ttyUSB* if all the above are correct.。

onsemi 2n7002k-d 数据表说明书

onsemi 2n7002k-d 数据表说明书

DATA SHEETSmall Signal MOSFET60 V, 380 mA, Single, N−Channel, SOT−232N7002K, 2V7002KFeatures•ESD Protected•Low R DS(on)•Surface Mount Package•2V Prefix for Automotive and Other Applications Requiring UniqueSite and Control Change Requirements; AEC−Q101 Qualified andPPAP Capable•These Devices are Pb−Free, Halogen Free/BFR Free and are RoHSCompliantApplications•Low Side Load Switch•Level Shift Circuits•DC−DC Converter•Portable Applications i.e. DSC, PDA, Cell Phone, etc.MAXIMUM RATINGS (T J = 25°C unless otherwise stated)Rating Symbol Value UnitDrain−to−Source Voltage V DSS60VGate−to−Source Voltage V GS±20VDrain Current (Note 1)Steady State 1 sq in Pad T A = 25°CT A = 85°C I D380270mADrain Current (Note 2)Steady State Minimum Pad T A = 25°CT A = 85°C I D320230mAPower Dissipation Steady State 1 sq in PadSteady State Minimum Pad P D420300mWPulsed Drain Current (t p = 10 m s)I DM 5.0AOperating Junction and Storage Temperature Range T J, T STG−55 to+150°CSource Current (Body Diode)I S300mA Lead Temperature for Soldering Purposes(1/8″ from case for 10 s)T L260°C Gate−Source ESD Rating(HBM, Method 3015)ESD2000VStresses exceeding those listed in the Maximum Ratings table may damage the device. If any of these limits are exceeded, device functionality should not be assumed, damage may occur and reliability may be affected.1.Surface−mounted on FR4 board using 1 sq in pad size with 1 oz Cu.2.Surface−mounted on FR4 board using 0.08 sq in pad size with 1 oz Cu.Device Package Shipping†ORDERING INFORMATION2N7002KT1G,2V7002KT1G3000 / Tape & Reel SIMPLIFIED SCHEMATICSOT−23CASE 318STYLE 21704 M GGMARKING DIAGRAM& PIN ASSIGNMENT321DrainGate SourceSOT−23(Pb−Free)60 V1.6 W @ 10 VR DS(on) MAX380 mAI D MAXV(BR)DSS†For information on tape and reel specifications, including part orientation and tape sizes, please refer to our T ape and Reel Packaging Specifications Brochure, BRD8011/D.2.5 W @ 4.5 VDrain(Top View)704= Specific Device Code*M= Date Code*G= Pb−Free Package2N7002KT7G3500 / Tape & ReelSOT−23(Pb−Free)*Specific Device Code, Date Code or overbarorientation and/or location may vary depend-ing upon manufacturing location. This is arepresentation only and actual devices maynot match this drawing exactly.(Note: Microdot may be in either location)THERMAL CHARACTERISTICSCharacteristic Symbol Max Unit Junction−to−Ambient − Steady State (Note3)R q JA300°C/W Junction−to−Ambient − t ≤ 5 s (Note 3)92Junction−to−Ambient − Steady State (Note4)417Junction−to−Ambient − t ≤ 5 s (Note 4)1543.Surface−mounted on FR4 board using 1 sq in pad size with 1 oz Cu.4.Surface−mounted on FR4 board using 0.08 sq in pad size with 1 oz Cu.ELECTRICAL CHARACTERISTICS (T J = 25°C unless otherwise specified)Parameter Symbol Test Condition Min Typ Max Unit OFF CHARACTERISTICSDrain−to−Source Breakdown Voltage V(BR)DSS V GS = 0 V, I D = 250 m A60V Drain−to−Source Breakdown VoltageTemperature CoefficientV(BR)DSS/T J71mV/°CZero Gate Voltage Drain Current I DSS VGS = 0 V,V DS = 60 V T J = 25°C1m A T J = 125°C10V GS = 0 V,V DS = 50 VT J = 25°C100nA Gate−to−Source Leakage Current I GSS V DS = 0 V, V GS = ±20 V±10m AV DS = 0 V, V GS = ±10 V450nAV DS = 0 V, V GS = ±5.0 V150nA ON CHARACTERISTICS (Note 5)Gate Threshold Voltage V GS(TH)V GS = V DS, I D = 250 m A 1.0 2.3V Negative Threshold TemperatureCoefficientV GS(TH)/T J 4.0mV/°C Drain−to−Source On Resistance R DS(on)V GS = 10 V, I D = 500 mA 1.19 1.6WV GS = 4.5 V, I D = 200 mA 1.33 2.5Forward Transconductance g FS V DS = 5 V, I D = 200 mA530mS CHARGES AND CAPACITANCESInput Capacitance C ISSV GS = 0 V, f = 1 MHz,V DS = 20 V 24.545pFOutput Capacitance C OSS 4.28.0 Reverse Transfer Capacitance C RSS 2.2 5.0Total Gate Charge Q G(TOT)V GS = 4.5 V, V DS = 10 V;I D = 200 mA 0.7nCThreshold Gate Charge Q G(TH)0.1 Gate−to−Source Charge Q GS0.3 Gate−to−Drain Charge Q GD0.1 SWITCHING CHARACTERISTICS, V GS = V (Note 6)Turn−On Delay Time t d(ON)V GS = 10 V, V DD = 25 V,I D = 500 mA, R G = 25 W 12.2nsRise Time t r9.0 Turn−Off Delay Time t d(OFF)55.8 Fall Time t f29 DRAIN−SOURCE DIODE CHARACTERISTICSForward Diode Voltage V SD VGS = 0 V,I S = 200 mA T J = 25°C0.8 1.2V T J = 85°C0.7Product parametric performance is indicated in the Electrical Characteristics for the listed test conditions, unless otherwise noted. Product performance may not be indicated by the Electrical Characteristics if operated under different conditions.5.Pulse Test: pulse width ≤ 300 m s, duty cycle ≤ 2%6.Switching characteristics are independent of operating junction temperaturesFigure 1. On −Region CharacteristicsFigure 2. Transfer CharacteristicsV DS , DRAIN −TO −SOURCE VOLTAGE (V)V GS , GATE −TO −SOURCE VOLTAGE (V)Figure 3. On −Resistance vs. Drain Current andTemperatureFigure 4. On −Resistance vs. Drain Current andTemperatureI D , DRAIN CURRENT (A)Figure 5. On −Resistance vs. Gate −to −SourceVoltage Figure 6. On −Resistance Variation withTemperatureV GS , GATE −TO −SOURCE VOLTAGE (V)T J , JUNCTION TEMPERATURE (°C)I D , D R A I N C U R R E N T (A )I D , D R A I N C U R R E N T (A )R D S (o n ), D R A I N −T O −S O U R C E R E S I S T A N C E (W )R D S (o n ), D R A I N −T O −S O U R C E R E S I S T A N C E (W )R D S (o n ), D R A I N −T O −S O U R C E R E S I S T A N C E (N O R M A L I Z E D )I D , DRAIN CURRENT (A)R D S (o n ), D R A I N −T O −S O U R C E R E S I S T A N C E (W )Figure 7. Capacitance VariationFigure 8. Gate −to −Source andDrain −to −Source Voltage vs. Total ChargeQg, TOTAL GATE CHARGE (nC)Figure 9. Diode Forward Voltage vs. CurrentV SD , SOURCE −TO −DRAIN VOLTAGE (V)V G S , G A T E −T O −S O U R C E V O L T A G E (V )I S , S O U R C E C U R R E N T (A)C , C A P A C I T A N C E (p F )GATE −TO −SOURCE OR DRAIN −TO −SOURCE VOLTAGE (V)Figure 10. Threshold Voltage withTemperatureT J , JUNCTION TEMPERATURE (°C)V G S (T H ), T H R E S H O L D V O L T A G E (V )0.11101000.0000010.000010.00010.0010.010.11000Figure 11. Thermal Response − 1 sq in padt, PULSE TIME (s)R q J A (t ) (°C /W ) E F F E C T I V E T R A N S I E N T T H E R M A L R E S I S T A N C E11010010000.11101000.0000010.000010.00010.0010.010.11000Figure 12. Thermal Response − minimum padt, PULSE TIME (s)R q J A (t ) (°C /W ) E F F E C T I V E T R A N S I E N T T H E R M A L R E S I S T A N C E1101001000SOT −23 (TO −236)CASE 318−08ISSUE ASDATE 30 JAN 2018SCALE 4:11XXXM G G XXX = Specific Device Code M = Date Code G = Pb −Free Package*This information is generic. Please refer to device data sheet for actual part marking.Pb −Free indicator, “G” or microdot “ G ”,may or may not be present.GENERICMARKING DIAGRAM*NOTES:1.DIMENSIONING AND TOLERANCING PER ASME Y14.5M, 1994.2.CONTROLLING DIMENSION: MILLIMETERS.3.MAXIMUM LEAD THICKNESS INCLUDES LEAD FINISH.MINIMUM LEAD THICKNESS IS THE MINIMUM THICKNESS OF THE BASE MATERIAL.4.DIMENSIONS D AND E DO NOT INCLUDE MOLD FLASH,PROTRUSIONS, OR GATE BURRS.SOLDERING FOOTPRINTDIM A MIN NOM MAX MINMILLIMETERS0.89 1.00 1.110.035INCHES A10.010.060.100.000b 0.370.440.500.015c 0.080.140.200.003D 2.80 2.90 3.040.110E 1.20 1.30 1.400.047e 1.78 1.90 2.040.070L 0.300.430.550.0120.0390.0440.0020.0040.0170.0200.0060.0080.1140.1200.0510.0550.0750.0800.0170.022NOM MAX L1STYLE 22:PIN 1.RETURN2.OUTPUT3.INPUT STYLE 6:PIN 1.BASE2.EMITTER3.COLLECTOR STYLE 7:PIN 1.EMITTER2.BASE3.COLLECTORSTYLE 8:PIN 1.ANODE2.NO CONNECTION3.CATHODESTYLE 9:PIN 1.ANODE2.ANODE3.CATHODE STYLE 10:PIN 1.DRAIN2.SOURCE3.GATE STYLE 11:PIN 1.ANODE 2.CATHODE 3.CATHODE −ANODE STYLE 12:PIN 1.CATHODE2.CATHODE3.ANODE STYLE 13:PIN 1.SOURCE2.DRAIN3.GATESTYLE 14:PIN 1.CATHODE2.GATE3.ANODESTYLE 15:PIN 1.GATE2.CATHODE3.ANODE STYLE 16:PIN 1.ANODE2.CATHODE3.CATHODE STYLE 17:PIN 1.NO CONNECTION2.ANODE3.CATHODE STYLE 18:PIN 1.NO CONNECTION 2.CATHODE 3.ANODE STYLE 19:PIN 1.CATHODE 2.ANODE 3.CATHODE −ANODE STYLE 23:PIN 1.ANODE2.ANODE3.CATHODESTYLE 20:PIN 1.CATHODE2.ANODE3.GATE STYLE 21:PIN 1.GATE2.SOURCE3.DRAIN STYLE 1 THRU 5:CANCELLEDSTYLE 24:PIN 1.GATE2.DRAIN3.SOURCESTYLE 25:PIN 1.ANODE2.CATHODE3.GATESTYLE 26:PIN 1.CATHODE2.ANODE3.NO CONNECTIONSTYLE 27:PIN 1.CATHODE2.CATHODE3.CATHODE2.10 2.40 2.640.0830.0940.104H E 0.350.540.690.0140.0210.027c0−−−100−−−10T°°°°END VIEWDIMENSIONS: MILLIMETERS3X3XRECOMMENDED STYLE 28:PIN 1.ANODE2.ANODE3.ANODEMECHANICAL CASE OUTLINEPACKAGE DIMENSIONSON Semiconductor and are trademarks of Semiconductor Components Industries, LLC dba ON Semiconductor or its subsidiaries in the United States and/or other countries.ON Semiconductor reserves the right to make changes without further notice to any products herein. ON Semiconductor makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does ON Semiconductor assume any liability arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation special, consequential or incidental damages. ON Semiconductor does not convey any license under its patent rights nor thePUBLICATION ORDERING INFORMATIONTECHNICAL SUPPORTNorth American Technical Support:Voice Mail: 1 800−282−9855 Toll Free USA/Canada Phone: 011 421 33 790 2910LITERATURE FULFILLMENT :Email Requests to:*******************onsemi Website: Europe, Middle East and Africa Technical Support:Phone: 00421 33 790 2910For additional information, please contact your local Sales Representative。

NX-700中文说明书

NX-700中文说明书

航行告警接收机NX-700A/B操作说明书* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *确认键指针键进入/推出菜单键开启LIST 选项 开启打印选项开/关键版本号按键说明一、 开机/关机按 键开机,显示器会发出“必”声,显示器会显示开机屏,如下图:1、ROM 、RAM 操作检查OK ,会显示:2、如检查到错误操作,所有的信息都在518KHz 下显示,如下:亮度调节按选择518KHz或490KHz.按关机。

二、 调节亮度按调整亮度,0(全黑)至9(最亮),+ 增加,- 减少。

三、 确认新信息SAR(搜救)信息1、当接收到一个SAR信息时,回显示信息内容及响报警。

SAR 信息图标2、按开关键以外的任意键静音。

其他信息1、收到SAR信息以外的信息,显示如下其中之一:国际信息本地信息2、如直接读取,按键选择“YES”然后按ENT键;3、如想以后再读取,选择“NO”,然后按ENT键关闭窗口。

四、 信息例子按选择键上的选择一个信息,然后按ENT键显示信息内容。

按ENT键在信息清单和信息明细之间转换。

注意:1、显示屏下方的操作指南显示当前显示下可用的按键;2、字体大小可调整,详细见。

按键显示模式功能清单滚动清单详细滚动信息清单转换国际及本地信息详细显示最新()及之前()的信息清单显示主菜单MENU详细清单显示所选择的信息明细ENT详细显示信息清单清单显示菜单选项LIST详细清单显示打印选项PRINT详细五、 选择接收模式有自动及手动两种接收模式选择:AUTO MODE(自动模式)要求航行数据,接收机会根据本船与NA VTEX地面站之间的距离选择。

如果没有输入航行数据,会选择所有的地面站。

ISN模式允许选择模式1、按MUNE/ESC 键,进入主菜单;2、按选择 NA VTEX。

3、按ENT键或键打开NA VTEX菜单;4、按选择接收模式,然后按ENT键或显示所选择的接收模式。

MD-700 Nafion 干燥器用户手册说明书

MD-700 Nafion 干燥器用户手册说明书

Large Diameter Dryer for Aerosol AnalysisControl Humidity in Your Samples Without Particle LossesThe MD-700 has been specifically developed for humidity control in particle measurement and aerosol analysis applications. In order to minimize particle losses, a laminar sample flow should be maintained through the flow path of the dryer. The MD-700 addresses these performance needs while providing the moisture removal necessary to make accurate measurements across a wide range of flow rates. All moisture is removed in the vapor phase with a purge gas flow.Some features and benefits of the dryer:•Low Particle Losses — Large diameter Nafion® tubing maintains a laminar flow of the sample through the dryer.•Eliminate Heating — Volatile particulates are preserved in the sample by eliminating the need to heat the sample to control RH.•Low Service Costs — Eliminates the need to repeatedly replace desiccant.•Three Modes of Operation — Designed for use with instrument air, vacuum purge or partial reflux methods.•Stainless Steel Construction — Grounded Stainless Steel construction eliminates build up of static charges in the flow path.•Long Service Life — Replaceable Nafion® dryer elements are available to extend service life.• Available in four sizes for specific flow rates:o15 cm (6”) – 0-1.5 lpmo30 cm (12”) – 1.5-4 lpmo60 cm (24”) – 3-8 lpmo90cm (36”) – 6-12 lpmo120 cm (48”) – 8-16.7 lpmLarge Diameter Dryer for Aerosol Analysis•Performance curves shown below are for the 60 cm (24”) and 120cm (48”) versions operated in 80% reflux mode (80% of the sample flow is returned to the dryer for used as the purge gas) at 25° C ambienttemperature.Operating condition limits –•Pressure -o Maximum of 1000 mbar (15 psid) positive pressure differential between the sample gas and purge gas volumes (higher pressure on the sample volume).o Maximum of 200 mbar (3 psid) negative pressure differential between the sample gas and purge gas volumes (higher pressure on the purge volume).•Temperature –o0-40° C range•Humidity –o0-99% RH (non-condensing)Large Diameter Dryer for Aerosol AnalysisModes of operation -There are three typical modes used to purge the dryer of water vapor. Each of the modes has its advantages and disadvantages but all are simple to configure and operate. In each case, the outlet humidity can be changed by adjusting the purge vacuum level and or flow. Typically, in the case of the split sample and reflux modes, higher purge vacuum reduces sample gas outlet humidity and lower purge vacuum increases sample gas outlet humidity."Reflux" mode employs a vacuum pump to purge the dryer. In this mode, a portion to 100% of the dry sample gas that is exhausted from the analyzer is returned to the dryer, expanded through a needle valve or other flow restrictor, and used as the purge gas. This requires a tube in addition to the sample gas tube to be connected to the analyzer.•Schematic Diagram – RefluxSee notes Array•Purge vacuum range: 20in-hg vacuum (336 millibar abs.) to full vacuumNotes:1.If the analyzer incorporates its own sample gas pump, it is recommended that the outlet be vented to atmosphere asshown. This will ensure that the pressure in the analyzer is not affected in the event the analyzer’s sample pump and thepurge vacuum pump are operated at different flow rates. Depending on the purge vacuum pump performance curve,controlling the purge flow rate at a lower level than the analyzer sample flow rate will be desireable and will increasedrying performance.2.If the analyzer does not incorporate its own sample gas pump, the dryer purge vacuum pump may be used to draw thesample gas through the entire circuit. In this case,the atmospheric vent must be closed."Split Sample" mode is essentially the same as the "reflex "mode except the sample gas is split into two flows after it exits the dryer. One stream flows to the analyzer and the other stream flows back to the dryer to be used as the dryer purge gas. The main advantages of this mode over the reflux mode are only one tube is needed torun to the analyzer, the drying process is independent of the analyzer, and none of the sample gas needs to bereturned to the dryer once it exhausts from the analyzer. The disadvantage is that this creates the need for additional sample flow through the dryer to be used as purge gas. To maintain a similar level of drying performance to that of the reflux mode, there is a need for a somewhat larger vacuum pump that can generate a deeper vacuum. In order to optimize drying performance, the dryer purge flow rate must be minimized as to not unnecessarily increase the total flow rate through the dryer. This also allows the pump to generate purge vacuum that is as deep as possible.Large Diameter Dryer for Aerosol AnalysisSchematic Diagram – Split Sample•Purge vacuum range: 25in-hg vacuum (167 millibar abs.) to full vacuum"Normal" mode is the most basic configuration. There are no moving parts and it is quieter than having a vacuum pump running continually but requires that instrument grade air be available for use as the dryer purge gas. In general, more purge flow reduces sample gas outlet humidity, less increases sample gas outlet humidity.•Schematic Diagram – Normal•Purge air humidity: Oil-less air, Instrument grade air is required, -40° C range dew point or below.•Purge air flow rate: 2x the sample flow rate. (Additional flow will be of little or no benefit)Large Diameter Dryer for Aerosol AnalysisFigure 1 - Assembly DrawingFigure 2。

现代N700E系列变频器说明书

现代N700E系列变频器说明书

Hyundai Inverter | The Controlling Solution of Powerful Inverter Brand |▶▶▶▶▶▶Series with Powerful Control Solution |Excellent Applicability to Various Loads||Easy Maintenance & Simple Repair||High Reliability & Durability||Compliance with RoHS||Lower Audible Noise |Model Name IndicationModel Name Indication3-Phase, 440V 3-Phase, 220V Series nameApplicable motor capacity Power source L : 3-Phase, 220V H : 3-Phase, 440V5.57.5111518.522N700E-055LF N700E-075LF N700E-110LF N700E-150LF N700E-185LF N700E-220LFN700E-055HF N700E-075HF N700E-110HF N700E-150HF N700E-185HF N700E-220HFApplicable motor capacity(kW)N700E055 : 5.5kW 220 :22.0kW��With digital operator055L FModel ConfigurationC o n t e n t s06Features / 09Dimensions / 10Specifications 12Operations / 13Function Lists / 19Protective Functions 20Terminal Functions / 22Connecting Diagram / 23Connection to PLC24Wiring and Options / 26For Correct Operation|Features|::Improved Control PerformanceHigh Torque Performance in Ultra Low Speed Zone by Using Sensorless Vector Control■Hyundai’s advanced sensorless vector control technology provides a motor with high torque performance in ultra low speed zone (Sensorless vector control: above 150% at 1Hz).■In case of fast acceleration/deceleration of motor, N700E series provides powerful torque controllability without trip.■Sensorless vector control technology expands the range of controlling speed.Superb Speed Control Performance by Improved Tuning Technology for Motors■Through technology of compensating the motor time constant while motor tuning minimizes the speed change, stable motor operation can be achieved.■After auto-tuning operation for motor time constant, N700E series minimizes the controls of speed so that the rate of speed variance can be reduced significantly while running.Intensified Protective Functions for Safety while Running■Ground fault protection can prevent accidents.■Countermeasure for output’s phase loss protects motor while running.Improved PID Control Performance■Built in PID function uniformly controls oil pressure and flow quantity without additional options.::Easy Operation and MaintenanceVarious Inverter Display Functions■The operational status of the inverter are displayed on the monitor so that an user can understand the condition of the inverter.■Cumulative hours of driving time and the actual running time are displayed for easy maintenance.Compact Size■Compact size of N700E series utilizes conventional panel even when changing model.■N700E series has the same size with the N300 series so that there is no need of changing panel while changing inverter models (5.5kW model excluded).Convenient Maintenance and Repair■N700E is available to replace the fan without separation.■Fan on/off function increases fan’s durability and minimizes fan’s noise.::Enhanced Compliance with Global Market Standard::Various Load Compatibility|Features |Fan & PumpWater supply pump Cooling water circulation pumpBoiler water supply pumpAir Conditioning & Dust Collecting Fan■Energy saving by selecting torque characteristic of a load ■Restart function in case of momentary power interruption ■Factory automation by PLC■Machine protection by soft start/stop ■Auto operation by precise PID control function ■Low noise operation■Quick responsiveness to load change by frequency jump andmulti speed operationCooling Tower■Stable operation by supplying high qualified energy ■Energy saving by speed and torque controlConveyor & Transport Machine|Dimensions||Specifications|Standard 200V ClassStandard 400V ClassStandard 200V, 400V Class|Operations|OperationsStandard Operator SettingDisplay Running Frequencyboth sides of operator and terminal)When the inverter is run through b15Set output frequency.Store the selected data or the set value.Lamp for the controlling powerDisplays frequency, motor current,motor rotational number, alarm settingRun the inverter. RUN key is disabled when the inverter is selected to run by terminal. RUN key is available only while the above LED is on.Increase/decrease frequency value,and modify set values���oncePush FUNC onceStore data by pushing STR Displays current running frequencyoncePush �4 timesStartinverter by pushing RUN 0.00.0060.0060.02d 01A -- A --A 01A 01F 01F 01d 01F 01|Function Lists|Monitor Modes (d-group) & Basic Setting Modes (F-group)|Function Lists|Expanded Function A Mode|Function Lists|Expanded Function b ModeExpanded Function C Mode|Function Lists|Expanded Function C ModeMotor Constant Setting H Mode|Protective Functions|Error Codes|Terminal Functions|Explanation of Main Circuit TerminalsExplanation of Control Circuit TerminalsMain Circuit Terminal ArrangementShort bar Short bar Short bar Short bar|Connecting Diagram|Terminal Connecting Diagram|Connection to PLC|Connection with Input Terminals|Wiring and Options |※1) Use 600V, 75°C copper wire.Common Applicable Tools5.57.5111518.5225.57.5111518.522N700E-055LF N700E-075LF N700E-110LF N700E-150LF N700E-185LF N700E-220LF N700E-055HF N700E-075HF N700E-110HF N700E-150HF N700E-185HF N700E-220HFMore than 6More than 10More than 16More than 25More than 30More than 35More than 4More than 4More than 6More than 10More than 16More than 25666161616446101010M4M4M5M5M6M6M4M4M4M5M5M51.21.23.03.04.54.51.21.21.23.03.03.050A 50A 75A 100A 150A 150A 30A 30A 50A 50A 75A 75AHBS60N HBS60N HBS100N HBS100N HBS225N HBS225N HBS30N HBS30N HBS60N HBS100N HBS100N HBS100NHiMC32HiMC32HiMC50HiMC65HiMC80HiMC110HiMC18HiMC18HiMC32HiMC40HiMC40HiMC50200V Class400V ClassClassMotor Output (kW)Inverter Model Power Cable (mm 2) 1)R,S,T,U,V,W,PD,P External Resistorbetween P and RB (mm 2)Applicable ToolsScrew Size of TerminalTorque (N •m)Circuit Breaker(MCCB)Magnetic Contactor (MC)Wiring and Options|For Correct Operation |■Application to Motors | Application to General-purpose Motors�Before use, be sure to read through the Instruction manual to insure proper use of the inverter.�Note that the inverter requires electrical wiring; a trained specialist should carry out the wiring.�The inverter in this catalogue is designed for general industrial applications. For special applications in fields such as aircraft, nuclear power,transport, vehicles, clinics, and underwater equipment, please consult us in advance.�For application in a facility where human life is involved or serious losses may occur, make sure to provide safety devices to avoid a serious accident.�The inverter is intended for use with a three-phase AC motor. For use with a load other than this, please consult with us.■Application to Motors | Application to Special Motors■Notes on Use| Main Power Supply■Notes on Use | Installation Location and Operating EnvironmentAvoid installation in areas of high temperature, excessive humidity, or easy condensation of dew, as well as areas that are dusty, subject to corrosive gases, residue of grinding solution, or salt. Install the inverter away from direct sunlight in a well-ventilated room that is free of vibration.The inverter can be operated in the ambient temperature range from -10°C to 50°C■Notes on Peripheral Equipment SelectionHHIS-WC-CE-B27-00 ’09. 9, Designed by JC CommunicationHead Office 1 Jeonha-dong, Dong-gu, Ulsan, KoreaTel: 82-52-202-8101~8F ax: 82-52-202-8100Seoul140-2, Gye-dong, Jongno-gu, Seoul, Korea(Sales & Marketing)Tel: 82-2-746-7596, 8451Fax: 82-2-746-8448Orlando3452 Lake Lynda Drive, Suite 170, Orlando, Florida 32817, U.S.A.Tel: 1-407-249-7350Fax: 1-407-275-4940New Jersey300 Sylvan Avenue, Englewood Cliffs, NJ, 07632, U.S.A.Tel: 1-201-816-0286 Fax: 1-201-816-4083London2nd Floor, The Triangle, 5-17 Hammersmith Grove, London, W6 0LG, UKTel: 44-20-8741-0501Fax: 44-20-8741-5620Tokyo8th Fl., Yurakucho Denki Bldg.1-7-1, Yuraku-cho, Chiyoda-gu, Tokyo, 100-0006, JapanTel: 81-3-3212-2076, 3215-7159Fax: 81-3-3211-2093Osaka I-Room 5th Fl. Nagahori-Plaza Bldg. 2-4-8, Minami Senba, Chuo-Ku, Osaka, Japan, 542-0081Tel: 81-6-6261-5766, 5767 Fax: 81-6-6261-5818Dubai Level 2, Unit 205, Emaar Square-Bldg.4, Sheikh Zayed Road, P.O.Box 252458, Dubai, U.A.E.Tel: 971-4-425-7995Fax: 971-4-425-7996Sofia1271, Sofia 41, Rojen Blvd., BulgariaTel: 359-2-803-3200, 3220Fax: 359-2-803-3203Yangzhong No.9 Xiandai Road, Xinba Scientific and Technologic Zone, Yangzhong, Jiangsu, P.R.C. Zip: 212212, ChinaTel: 86-511-8842-0666, 0212 Fax: 86-511-8842-0668, 0231。

NA7004使用手册

NA7004使用手册

1
2
声音不同凡响。 奇怪 ? 常听的音乐变得更好听了。
您的音乐文件 将以更佳的音质进行播放。
只需将NA7004添加到家庭网络中,就会明显改善音乐文件的音质。 不仅是MP3、WMA、AAC,也适用于高音质的WAV与FLAC。也是音乐 发烧友非常认可的HiFi音质。而且,如果导入对应DLNA的NAS(网络 硬盘),无需启动PC即可欣赏音乐。
连接之后,即可奏出富有绝妙音质的音乐。 播放能力令人称奇。
配备有用于连接iPhone、iPod和U盘的USB端子。试试看,用NA7004 播放您经常聆听的音乐文件。想必您会惊叹于意想不到的绝妙音质 。
从耳机深处流淌出来的音乐也变得更加鲜艳动人。
请试着连接到NA7004配备的耳机端子上,欣赏您喜欢 的曲目。NA7004卓越的声音处理能力和宽广的音量, 会让您通过耳机欣赏的钟爱的音乐发生令人惊奇的变 化。
11
每个角落都达到了 HiFi 音频等级。
采用同等于引领纯音频世界潮流的马兰 士SACD播放机的由高性能部件构成的 模拟输出电路。对配线处理进行优化, 并采取降噪音等周密对策。
也可以利用 M-DAX2 恢复丢失的声音。
MP3等压缩格式省略了人耳难以听到的 信号,因此相应地减少了数据量。 NA7004可对省略的信号进行插入,使 声音接近压缩之前的状态。
播放机自身不会产生振动。
能够可靠Байду номын сангаас转换声音信号。
施加到设备上的振动无疑会对音质产生 恶劣影响。NA7004没有可能会导致振 动的驱动器,3件式结构的前面板与低 重心底盘也抑制了来自外部的振动。
NA7004采用了高级SACD播放机使用的 高性能D/A转换器。即使是高分辨率音 源,也可以高精度地转换为模拟声音信 号。

Uniwell NA-700系列网络适配器规格说明书

Uniwell NA-700系列网络适配器规格说明书

NA-710NA-720NA-730NA-740Note! AC-DC adapter is not supplied. Please prepare it by yourself referring page 1.This document includes the features for the ROM version NA-700-01-G. For the features for the later ROM versions, please refer to the ROM information.You can download the ROM information from our home page at For Distributor.May. 20, 2004 Uniwell NA-700 NA-710 NA-720 NA-730 NA-740 specification ManualCONTENTSI. GENERAL SPECIFICATIONS (1)II. INTRODUCTION (2)1. NA-710 (for 1 peripheral) (3)2. NA-730 (for 3 peripherals) (3)Reference samples on how to connect peripherals using NA-710/730 (4)3. NA-720 (for PC/modem) (5)a. Protocol Converter Mode (5)Reference samples on how to connect peripherals using NA-720 (6)b. Level Converter Mode (7)Reference samples on how to connect peripherals using NA-720 (8)4. NA-740 (used as multiplexer) (9)Reference samples on how to connect peripherals using NA-740 (10)III. SPECIFICATIONS FOR EACH MODEL (11)1. NA-710 (for one external printer) (11)2. NA-730 (for three external printers) (11)a. Appearance (11)b. Interface Information (12)c. Cable Connection Between NA-710/730 and CBM-231 (12)d. Dip Switch Settings (13)Only for NA-730 (13)3. NA-720 (for PC/modem) (14)a. Appearance (14)b. Interface Information (15)c. Recommended Cable Connections (15)d. Dip Switch Settings of Protocol Converter Mode (16)e. Dip Switch Settings of Level Converter Mode (17)f. Time Chart of RXD Control Mode (SW3-1 = ON) for Level Converter Mode (18)g. Time Chart of DCD/RTS Control Mode (SW3-1 = OFF) for Level Converter Mode (19)4. NA-740 (multiplexer) (20)a. Appearance (20)b. Interface Information (21)c. NA-740 Internal Connection (21)d. Dip Switch Settings (22)e. Time Charts (23)e-1. Communication Started by Master (23)Time Chart of RXD Selection Mode (23)Time Chart of CTS Selection Mode (25)Time Chart of Enhanced CTS Selection Mode (27)Time Chart of Enhanced Broadcast Mode (29)e-2. Communication Started by Slave (31)Time Chart of CTS Polling Mode (31)Time Chart of Channel Scan Mode (33)f. Configuration Samples (35)f-1. UX-60/70-05 (ch-B) with Thermal Slip Printer and 2 PCs (35)f-2. PC with 3 ECRs (36)f-3. UX-60-05 (ch-C) with 2 Scanners and Journal Data Monitor (37)This is a “Table of Contents preview” for quality assuranceThe full manual can be found at /estore/catalog/ We also offer free downloads, a free keyboard layout designer, cable diagrams, free help andsupport. : the biggest supplier of cash register and scale manuals on the net。

akgn700ncm2说明书

akgn700ncm2说明书

akgn700ncm2说明书
1、首次使用,尽量让耳机充上2-4个小时左右,以后充2小时即可,说明书上也是这么说的,最好不要超过4小时,有的论坛说一定要充24个小时是没有根据的,这么小个耳机,充24个小时,有些过于夸张。

2、点击手机设置中的蓝牙设置,选择“开启”,完成。

这就打开了手机的蓝牙支持功能。

3、在蓝牙耳机关闭状态,按住耳机多功能键MFB3秒以上,待耳机上的指示蓝灯亮起(1,注意是常亮,配对过程一直常亮,不是闪烁或不亮2,也有部分设备为红蓝交替闪烁),此时蓝牙耳机已处于可被查找状态。

4、打开手机上的蓝牙选项,进行查找,成功搜索到耳机后会在清单上显示蓝牙耳机名字和型号,点击确认。

5、在手机上输入密码(一般是0000),也有些没有密码,耳机指示灯快速闪烁,即配对成功。

6、点击蓝牙耳机名称项:MOTOROLAHS850,打开,选择绑定。

完成,手机就与蓝牙耳机连接上了。

此时手机可能有类似连上usb 的“叮咚”提示音,关闭蓝牙耳机时,也可能会有类似提示音,据此可以判断蓝牙耳机与手机是否已正常连接。

s700使用说明书(用户)

s700使用说明书(用户)

1概述 (7)1.1本说明书的用途 (7)1.2S700分析仪可以做什么 (7)1.2.1应用场合1.2.2应用限制1.3用户自己的责任 (8)1.3.1 一般责任1.3.2 测量有毒气体的特殊责任1.4S700分析仪用户指南 (9)1.4.1必须做什么?1.4.2可以做什么?1.4.3如果您希望了解操作功能1.5S700的特点 (11)1.5.1特点1.5.2分析模块1.5.3壳体类型1.5.4可选装置1.5.5用于UNOR和MULTOR模块的校准气室1.5.6横向灵敏度补偿1.5.7测量O2的分析模块1.5.8OXOR-P模块的横向灵敏度补偿1.5.9内部气路(流程图)1.5.10气接触部件材料1.5.11S720Ex / S721Ex的认证文件1.6用于涡轮发电机的特殊型号 (24)1.6.1 这种特殊型号的用途1.6.2 这种特殊型号的限制2安装 (25)2.1供货清单 (25)2.2安全说明 (25)2.3壳体安装 (27)2.3.1安装尺寸2.3.2安装位置和环境条件2.3.3壳体安装2.4样气连接 (29)2.4.1 正确的样气供给2.4.2 来自排放源的样气供给(举例)2.4.3 来自生产流程的样气供给(举例)2.4.4 通过NOx转化炉的样气供给2.4.5 样气接头2.4.6 样气气路连接2.4.7 不锈钢气路2.5 吹洗气连接(可选) (35)2.6校准气体供给 (35)2.6.1自动校准气体供给2.6.2装有样气制冷器的校准2.6.3H2O分析的特别说明2.7 打开和关闭壳体(不包括S700/S711) ............................ (36)2.7.1打开壳体前的安全措施2.7.2打开壳体2.7.3关闭壳体2.8 S720Ex/S721Ex电缆密封适配器的安装 (39)2.9电源连接 (39)2.9.1 电源连接的安全说明2.9.2 外接电源保险2.9.3改变需要的线性电压2.9.4连接电源电缆2.9.5 内部电源开关2.9.6 电气保险2.10信号连接 (44)2.10.1 端子连接2.10.2 信号电压输出2.10.3 允许最大负载和信号电缆参数2.10.4 信号连接的电感保护2.11测量值输出 (47)2.12模拟输入 (48)2.13开关输出 (48)2.13.1 开关功能2.13.2 电气功能2.13.3 接点连接(针式排列)2.14控制输入 (51)2.14.1 控制功能2.14.2 电气功能2.15本安型输出(可选) (51)2.16数字接口 (53)2.16.1 接口功能2.16.2 接口连接3启动 (55)3.1接通电源 (55)4 操作(一般说明) (57)4.1信号灯 (58)4.2状态信息 (58)4.3工作原理 (58)4.3.1 功能选择4.3.2菜单功能4.3.3键盘4.3.4 菜单层次5标准功能菜单 (61)5.1主菜单 (61)5.2测量显示 (61)5.2.1显示所有测量组分5.2.2显示所选测量组分5.2.3图表记录5.3状态显示 (64)5.3.1显示状态/故障信息5.3.2显示测量范围5.3.3显示测量值输出5.3.4显示报警极限值5.3.5显示仪器数据5.3.6显示漂移值5.4控制 (67)5.4.1 气泵开/关5.4.2确认报警5.4.3设定显示屏对比度5.4.4设定按键声音5.5校准 (69)5.6维修信号 (70)6校准 (71)6.1仪器校准介绍 (71)6.2校准气 (72)6.2.1程序设置校准气体6.2.2零点气(零点校准)6.2.3校准气(灵敏度校准)6.2.4单一校准气6.2.5校准气的正确供给6.3自动校准 (75)6.3.1自动校准设置显示6.3.2手动启动自动校准6.4.1校准气体供给方式6.4.2手动校准步骤6.4.3H2O的灵敏度校准6.5校准数据显示 (81)7专家功能菜单 (83)7.1进入专家功能菜单 (83)7.2时钟设置 (83)7.3测量值输出设置 (84)7.3.1选择取样点的特殊功能7.3.2选择测量组分7.3.3确定输出范围7.3.4显示输出范围7.3.5选择输出范围7.3.6活动零点设定/关闭某一测量值输出7.3.7校准过程中输出方式7.3.8取消某一测量值输出的设置7.4报警极限值 (87)7.5校准功能设置 (88)7.5.1不同的自动校准途径7.5.2自动校准前的准备7.5.3自动校准的确认7.5.4设置校准气体名义值7.5.5检查/设置校准气室名义值7.5.6设置漂移极限值7.5.7忽略外部校准信号7.5.8设置满度滞后时间7.5.9设置校准测量时间7.5.10设置校准期间横向灵敏度补偿7.6测量值显示 (93)7.6.1选择小数点位数7.6.2选择线段示意图范围7.6.3设置衰减(平均值计算)7.7取样点的选择 (94)7.7.1取样点选择器的功能7.7.2取样点选择器的注意事项7.7.3取样点选择器的确认7.8接口参数 (95)7.9 接口#1的通讯参数 (96)7.9.1设置ID字符7.9.2观察或忽略ID字符7.9.3设置与MARC 2000的连接7.9.4选择调制解调器的连接7.9.5调制解调器的控制7.10接口#2自动数据输出 (99)7.11设定和监测气体流量 (101)7.11.1 设定抽气泵的抽气量7.11.2 设定流量监测点7.12菜单语言选择 (101)7.13显示内部信号和设定值 (102)7.13.1 测量信号7.13.2 内部控制器的状态7.13.3 内部模拟信号显示7.13.4 内部供给电压7.13.5 内部模拟信号浏览7.13.6 桥臂调节7.13.7 线性化值7.13.8 输出仪器配置7.13.9 控制输入的状态7.13.10 软件版本7.14硬件测试 (106)7.15漂移置零 (107)7.16复位 (108)7.17基本校准 (108)7.17.1 基本校准的需要7.17.2 基本校准的基本步骤7.17.3 基本校准的要求7.17.4 基本校准步骤7.18程序下载 (112)8隐藏的专家功能菜单 (113)8.1进入隐藏的专家功能菜单 (113)8.2开关输出设置 (113)8.2.1功能原理8.2.2控制逻辑电路8.2.3安全准则8.2.4可选的开关功能8.2.5分配开关功能8.3控制输入设置 (115)8.3.1 可选的控制功能8.3.2 分配控制功能8.4 量程起始值附近的测量值消除 (116)8.5工作量程极限的报警 (116)8.6 存储仪器内设置 (117)8.7 数据传输 (118)9 M AR C2000软件远程控制 (119)9.1MARC2000远程控制的介绍 (119)9.2远程控制安装 (122)9.2.1电气连接9.2.2远程控制设置9.2.3PC机远程控制设置9.3开始和结束远程控制操作 (123)9.3.1开始远程控制9.3.2远程控制期间的状态信息9.3.3结束远程控制10维修 (125)10.1一般安全事项 (125)10.2维护计划 (125)10.3目检 (125)10.4测试电气信号 (126)10.5气密性检查 (126)10.6壳体清洁 (127)10.7 更换分析模块OXOR-E (127)11故障检查表 (129)11.1 如果S700 完全不工作 (129)11.2状态信息 (129)11.3如果测量值明显错误 (134)11.4如果测量值不稳定而你又不知道为什么 (134)12关机程序 (135)12.1避免冷凝的保护 (135)12.2关闭前的预防措施 (135)12.3关闭电源 (135)12.4注意事项 (136)13贮存和运输 (137)13.1正确存贮 (137)13.2正确运输 (137)13.3如果仪器需送回工厂修理 (137)适用范围本说明书适用于下列分析仪:- S710- S711- S715- S720Ex-S721ExS700 则包括了上述系列中的所有分析仪。

基思科N5700A系列和N8700A系列电源家族手册说明书

基思科N5700A系列和N8700A系列电源家族手册说明书

Keysight N5700A Series and N8700A Series Power Supply FamilyThis manual provides the documentationfor the following instruments:-N5741A through N5752A,-N5761A through N5772A,-N8731A through N8742A,-N8754A through N8762ANotices© Keysight Technologies 2019, 2020No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval or translation into a foreign language) without prior agreement and written consent from Keysight Technologies, Inc. as governed by United States and international copyright laws. Trademark AcknowledgementsN/A Manual Part Number5991-3419Print DateMarch, 2020Revision CPublished in USAKeysight Technologies1400 Fountaingrove ParkwaySanta Rosa, CA 95403WarrantyTHE MATERIAL CONTAINED INTHIS DOCUMENT IS PROVIDED“AS IS,” AND IS SUBJECT TOBEING CHANGED, WITHOUTNOTICE, IN FUTURE EDITIONS.FURTHER, TO THE MAXIMUMEXTENT PERMITTED BYAPPLICABLE LAW, KEYSIGHTDISCLAIMS ALL WARRANTIES,EITHER EXPRESS OR IMPLIEDWITH REGARD TO THIS MANUALAND ANY INFORMATIONCONTAINED HEREIN, INCLUDINGBUT NOT LIMITED TO THEIMPLIED WARRANTIES OFMERCHANTABILITY AND FITNESSFOR A PARTICULAR PURPOSE.KEYSIGHT SHALL NOT BE LIABLEFOR ERRORS OR FOR INCIDENTALOR CONSEQUENTIAL DAMAGES INCONNECTION WITH THEFURNISHING, USE, ORPERFORMANCE OF THISDOCUMENT OR ANYINFORMATION CONTAINEDHEREIN. SHOULD KEYSIGHT ANDTHE USER HAVE A SEPARATEWRITTEN AGREEMENT WITHWARRANTY TERMS COVERINGTHE MATERIAL IN THISDOCUMENT THAT CONFLICT WITHTHESE TERMS, THE WARRANTYTERMS IN THE SEPARATEAGREEMENT WILL CONTROL.Technology LicensesThe hardware and/or softwaredescribed in this document arefurnished under a license and maybe used or copied only inaccordance with the terms of suchlicense.Restricted Rights LegendIf software is for use in theperformance of a U.S. Governmentprime contract or subcontract,Software is delivered and licensedas “Commercial computersoftware” as defined in DFAR252.227-7014 (June 1995), or asa “commercial item” as defined inFAR 2.101(a) or as “Restrictedcomputer software” as defined inFAR 52.227-19 (June 1987) or anyequivalent agency regulation orcontract clause. Use, duplicationor disclosure of Software issubject to Keysight Technologies’standard commercial licenseterms, and non-DOD Departmentsand Agencies of the U.S.Government will receive nogreater than Restricted Rights asdefined in FAR 52.227-19(c)(1-2)(June 1987). U.S. Governmentusers will receive no greater thanLimited Rights as defined in FAR52.227-14 (June 1987) or DFAR252.227-7015 (b)(2) (November1995), as applicable in anytechnical data.Safety NoticesA CAUTION notice denotes ahazard. It calls attention to anoperating procedure, practice, orthe like that, if not correctlyperformed or adhered to, couldresult in damage to the product orloss of important data. Do notproceed beyond a CAUTION noticeuntil the indicated conditions arefully understood and met.A WARNING notice denotes ahazard. It calls attention to anoperating procedure, practice, orthe like that, if not correctlyperformed or adhered to, couldresult in personal injury or death.Do not proceed beyond aWARNING notice until theindicated conditions are fullyunderstood and met.Where to Find the Latest InformationDocumentation is updated periodically. For the latest information about these products, including instrument software upgrades, application information, and product information, see the following URLs:/find/n5700To receive the latest updates by email, subscribe to Keysight Email Updates:/find/MyKeysightIs your product software up-to-date?Periodically, Keysight releases software updates to fix known defects and incorporate product enhancements. To search for software updates for your product, go to the Keysight Technical Support website at:/find/techsupportTable of ContentsContacting Keysight Sales and Service Offices (5)Products Covered by this Document (6)Security Terms and Definitions (7)Instrument Memory (8)Summary of Memory Declassification Procedures (10)User and Remote Interface Security Measures (11)Memory Sanitization Procedures for Declassifying a Faulty Instrument. (12)References (13)Contacting Keysight Sales and Service OfficesAssistance with test and measurement needs, and information on finding a local Keysight office, is available on the Internet at:/find/assistIf you do not have access to the Internet, please contact your field engineer.In any correspondence or telephone conversation, refer to the instrument by its modelnumber and full serial number. With this information, the Keysight representative candetermine whether your unit is still within its warranty period.Products Covered by this DocumentFamily Name: N5700 Series and N8700 SeriesProduct Name: DC Power SupplyModel Numbers:N5741A, N5742A, N5743A, N5744A, N5745A, N5746A, N5747A, N5748A, N5749A, N5750A,N5751A, N5752AN5761A, N5762A, N5763A, N5764A, N5765A, N5766A, N5767A, N5768A, N5769A, N5770A,N5771A, N5772AN8731A, N8732A, N8733A, N8734A, N8735A, N8736A, N8737A, N8738A, N8739A, N8740A,N8741A, N8742AN8754A, N8755A, N8756A, N8757A, N8758A, N8759A, N8760A, N8761A, N8762ASerial Numbers: Applies to models that have serial numbers US14G0001X and above.This document describes instrument security features and the steps to declassify an instrument through memory clearing, sanitization or removal. For additional information, go to:/find/securityBe sure that all information stored by the user in the instrument that needs to be saved isproperly backed up before attempting to clear any of the instrument memory. KeysightTechnologies cannot be held responsible for any lost files or data resulting from the clearingof memory. Be sure to read this document entirely before proceeding with any file deletionor memory clearing.Security Terms and DefinitionsTerm DefinitionClearing As defined in Section 8-301a of DoD 5220.22-M, clearing is the process of eradicating the data on media before reusing the media so that the data can no longer be retrieved using the standardinterfaces on the instrument. Clearing is typically used when the instrument is to remain in anenvironment with an acceptable level of protection.Instrument Declassification A term that refers to procedures that must be undertaken before an instrument can be removed from a secure environment, such as is the case when the instrument is returned for calibration. Declassification procedures include memory sanitization or memory removal, or both. Keysight declassification procedures are designed to meet the requirements specified in DoD 5220.22-M, Chapter 8.Sanitization As defined in Section 8-301b of DoD 5220.22-M, sanitization is the process of removing or eradicating stored data so that the data cannot be recovered using any known technology.Instrument sanitization is typically required when an instrument is moved from a secure to a non-secure environment, such as when it is returned to the factory for calibration.Keysight memory sanitization procedures are designed for customers who need to meet therequirements specified by the US Defense Security Service (DSS). These requirements arespecified in the “Clearing and Sanitization Matrix” in Section 5.2.5.5.5 of the ISFO ProcessManual.Secure Erase Secure Erase is a term that is used to refer to either the clearing or sanitization features of Keysight instruments.Instrument MemoryThis section contains information on the types of memory available in your instrument. It explains the size of memory, how it is used, its location, volatility, and the sanitization procedure.Table 1: Summary of instrument memory for the DC Power Supply.Memory Type and SizeI s M e m o r y u s e r a c c e s s i b l e a s a m a s s s t o r a g e d e v i c eW r i t a b l e D u r i n g N o r m a l O p e r a t i o n ?D a t a R e t a i n e d W h e n P o w e r e d O f f ?Purpose/ContentsData Input MethodLocation in Instrument and RemarksSanitization ProcedureSystem Flash (NAND Flash) 79 MBNo Yes YesContains the operating system and instrument firwmare Factory Install / Firmware UpgradeCPU boardNo method, not user accessible, and contains no application-specific information. User Flash (NAND Flash) 42 MB Yes Yes Yessaved instrument states User-saved dataCPU board (same chip as firmware memory, butmanaged separately) See Table 2Keysight Flash (NAND Flash) 1 MBNo Yes Yes Not UsedFactory or Service OnlyCPU board (same chip as firmware memory, butmanaged separately)No method, not user accessible, and contains no application-specific information. Boot Flash (NAND Flash) 6 MBNo Yes YesBootloadercomponents that load the operating firmware from the NAND flash memory Factory InstallCPU board (same chip as firmware memory, butmanaged separately)No method, not user accessible, and contains no application-specific information. FPGA14.6 K cells No Yes No GPIB control data and registersFactory Install CPU boardPower cycle PROMM25P40 FLASH Memory 4 MB NoNoYesFPGA program code. No user stored data.Factory Service OnlyCPU boardNo method, not user accessibleMain processor (ROM) 32 kBNoNoYesMain processor execution codeManufacturer programmedCPU boardNo method, not user accessible, and contains no application-specific information.Table 1 - continuedMemory Type and SizeI s M e m o r y u s e r a c c e s s i b l e a s a m a s s s t o r a g e d e v i c eW r i t a b l e D u r i n g N o r m a l O p e r a t i o nD a t a R e t a i n e d W h e n P o w e r e d O f f ?Purpose/ContentsData Input MethodLocation in Instrument and RemarksSanitization ProcedureMain processor (SRAM) 8 kBNo Yes NoTemporary execution data Operating System CPU boardPower cycleMain RAM (SDRAM) 1 G-bit No Yes No Temporary execution data Operating System CPU board Power cycle EEPROM 2 KbNoYesYesCalibrationconstants, model and serial numberFactory Service OnlyMain boardNo method, not user accessibleSummary of Memory Declassification ProceduresThis section explains how to clear, sanitize, and remove memory from your instrument, for all classes of memory that are writeable during normal operation and for which the clearing and sanitization procedure is more than trivial such as rebooting your instrument.Before beginning clearing or sanitization, be sure to write down and save the instrument’sModel, Serial number, Option, and software License Key information. Read this entiredocument before using any sanitization procedure. Failure to do so may necessitatereturning the instrument to an Authorized Keysight Service Center for firmware downloadsand recalibration.Table 2: NAND Flash Part B (User Flash)Description and purpose User preferences and instrument statesSize 42 MBMemory clearing No procedureMemory sanitization On the remote interface send: SYSTem:SECurity:IMMediateThis procedure clears all instrument memory except for the instrument’s firmware, MACaddress and serial number and calibration data, and then reboots the instrument to thenew memory state. This routine writes all zeros to memory and then performs a full chiperase as per manufacturer’s data sheet. This procedure is not recommended for use inroutine applications because of the possibility of unintended loss of data.Memory removal If product is not operational contact Keysight \find\contactusWrite protecting N/ARemarks N/AUser and Remote Interface Security MeasuresScreen and Annotation BlankingNot SupportedRemote Access InterfacesThe user is responsible for providing security for the I/O ports for remote access bycontrolling physical access to the I/O ports. The I/O ports must be controlled because they provide access to all user settings, user states and the display image.The I/O ports include USB, GPIB, and LAN.Memory Sanitization Procedures for Declassifying a Faulty Instrument.If the instrument is not functioning and you are unable to use the security functions, contact Keysight /find/contactus.You must physically remove the processor boards from the power supply. Once this assembliy is removed, destroy the processor board and send the instrument to a Keysight repair facility. If the repair facility determines that a new processor board fixes the problem and the instrument is still under warranty, you will not be charged for the new board. If they determine that the failure was caused by something other than the processor board, you will be charged for the new board even though the instrument is still under warrantyThis information is subject to change without notice© Keysight Technologies, 2019, 2020March, 2020 Revision C5991-3419References1. DoD 5220.22-M, “National Industrial Security Program Operating Manual (NISPOM)”United States Department of Defense. Revised May 18, 2016.May be downloaded in Acrobat (PDF) format from:/isp/fac_clear/download_nispom.html2. ISFO Process Manual for the Certification and Accreditation of Classified Systems under the NISPOMDefense Security Service./documents/odaa/ODAA%20Process%20Manual%20Version%203.2.pdf。

NX700中文说明

NX700中文说明

User Select Station
(站台)按 LIST 键,在 User Select Station 选项中选择站台显示。
(信息)按 LIST 键,在 User Select Station 选项中选择信息类显示。
注 1:用于显示信息时,报警信息一直显示。
注 2:在 NAVTEX 菜单中选择 User Select 打印时,只打印选择的这一块儿。
(1) 按 MENU/ESC 键显示主菜单。
(2) 按▲▼键选择 NAVTEX,然后按 ENT 或 键进入。
(3) 按▲▼键选择 Rcv Station & Msg 或 User Select Station。
(4) 按 ENT 键打开合适的编辑窗口(图示:Rcv Station Msg 编辑窗口)
(4) 按
选择要删除的 NAV Area(01-16,EXT)
(5) 按 LIST 键选择频率(518KHz,490KHz 和 4209.5KHz)。
(6) 按▲或▼选择要删除的 Station Name, 按 ENT 键出示项目窗口。
(7) 按▲▼选择 Delete, 按 ENT 键出现提示信息“Delete Station”。
10、打印信息 接收的信息可以自动或手动通过内置打印机(NX-700A)或外置打印机(NX-700B)打印。 打印所有显示的信息:按照第 9 方式 LIST 菜单所描述的显示信息,按下列方式进行打印: 显示所有信息后按 PRINT 键出示 Print option 选项,按▲▼键选择 Print,按 ENT 键打印。
(10) 按 选择 YES,按 ENT 键关闭编辑窗口。
(11) 持续按 MENU/ESC 键几秒钟关闭菜单。
删除 NAVTEX Station:

Real Time Automation 460BMSTCP-N700 产品说明说明书

Real Time Automation 460BMSTCP-N700 产品说明说明书

460BMSTCP-N700CONTACT US!1-800-249-1612 Real Time Automation GatewaysA Solution, A Philosophy, the RTA Way. We understand the long hours spent on a factory floor and thepressure to keep a line running and product flowing. That’s how Real Time Automation came to be. Youwant easy-to-use solutions where the hardest part is to open the box. You need customer support secondto none. If you get all that and a fun customer experience all the better. Thirty years later, our mission remains the same: To move your data where you need it, when you need it, and how you need it.Get Ethernet TCP/IP Data into your BACnet MS/TP NetworkThe 460BMSTCP moves data between up to 10 Ethernet TCP/IP devices and a BACnet MS/TPBuilding Automation System (BAS). It’s the perfect tool to tie Ethernet TCP/IP devices into your BACnet MS/TP building automation system.A great tool to connect printers, RFID devices, LED displays, and PC applications to a BACnet MS/TP system.How Do I Use the 460BMSTCP-N700 in My Application?BACnet analog, binary, and CSV data segments can be converted to ASCII anddelivered to your ASCII controller. If you need to command the BACnet/IP servers, an incoming ASCII string can be parsed and directed to user-defined data location. It really is that simple.Why Use Real Time Automation as a Gateway Supplier?While there are certainly other companies offering protocol gateways, there is no one who provides the level of support and service that you receive from RTA. When you call, a live person answers the phone. When you talk with sales, you will get honest answers and recommendations. When you get support, it is from an engineer who had a hand in the product’s development, and support doesn’t require a ticket or 24-hour wait.FEATURES •Fully configurable BACnet MS/TPresponder•BACnet MS/TPsupports device, binaryI/O, analog I/O, andcharacter string value object types•Support up to 10TCP/IP devices •Parse & concatenate ASCII data in up to 50 segments by delimiteror offset•Effortless Browser Based Configuration, no programmingsoftware is required• Simple data translationallows you to manipulate data as itpasses between protocols• Guaranteed Stock •5-Year Hardware WarrantyReal Time Automation, Inc.************************** - 1-800-249-1612Made in theU.S.A.Always InStockReady toShipExpertSupportBACnet MS/TP Slave Operation ModeBACnet MS/TP Master ResponderSupported Object Types Device, Binary I/O, Analog I/O, Character String ValueSupported Service CodesRead & Read Multiple-B, Write & Write Multiple-B, COV & COV unsolicited-B, Device DynamicBinding-B, Dynamic Object Binding-B Maximum Connections 1Analog Objects Supported 1200 Input and 1200 Output Binary Objects Supported 1600 Input and 1600 OutputEthernet TCP/IP Operation ModeClient or Server Maximum Number of Devices Supported10 Maximum Number of Characters Transferred 1024Delimiter ProcessingIncoming delimiters can be automatically removed; Outgoing delimiters automatically added if configuredParsingParse String of ASCII Data in up to 50 Segments by Delimiter or OffsetConcatenationConcatenate up to 50 segments/strings of ASCII data with optional delimiter INCLUDED WITH GATEWAY 3’ power cable with flying leads5-year hardware warrantyIPSetup software – automatically locates RTA gateway on the networkUnlimited firmware feature upgrades for lifeCAT5 crossover cable for direct connection to PC during programming Complete, unlimited access to our industry leading support staff ManualELECTRICAL / ENVIRONMENTALDC Input Voltage 12-24 VDC .Maximum Baud Rate 115K baud Operating Temperature -40 C to 85 CCertificationRoHS-Compliant, UL, CUL, CE Approvals ENCLOSURE / HARDWARE Size 4.19" x 3.25" x 1" Weight6.5 ozEnclosure Type Anodized Aluminum Mounting Din rail or panel mountLEDsPower LED, Ethernet link/data LED, & Ethernet speed LEDGATEWAY FEATURES & FUNCTIONSAlarming Set <, <=, >, >=, ==, !=, and change-of-state ruleson any data moving through the gateway. If alarmrule is triggered an email notification can be sent. Gateway SecurityYou can configure up to 9 different users access todiagnostic and configuration screens. Translation TableAllows for data manipulation during protocol translation. Scaling and other data format changes can occur in the gateway.Status and CountersProtocol specific status, counters, and error messages are accessible within the gateway’s diagnostics page. They can also be delivered to a connected device.NOT EXACTLY WHAT YOU WERE LOOKING FOR? Real Time Automation offers a full line of gateway products. Give us a call at 1-800-249-1612. Or, check out a listing at/products . We also offercustomizations for unique applications.Diagnostic Logging PageAllows users to see and log start up sequences, protocol specific messages & error messages.CATALOG # DESCRIPTION460BMSTCP-N700Connects a BACnet MS/TP master with up to 10 Ethernet TCP/IP devices。

NM7000仪表着陆设备

NM7000仪表着陆设备
NM7000仪表着陆设备
• 授课人:李炳军 • 2007-4
第五章NM7000仪表着陆设备概述
第一节 系统简介
• NM7000系统仪表着陆设备是由原 挪威挪玛克公(Normarc a/s)生 产的,该公司现已更名为挪威亚公 司(NAVIA AVIATION),其性能指 标符合国际民航组织附件10的各项 指标要求。NM7000设备是在该公司 的原NM3500型号基础的升级产品, 我国民航从1996年开始引进NM7000 设备,目前国内已经配置了近百套, 是国内目前各机场重要的仪表着陆 引导设备。NM7000的主要产品有单 频航向NM7011/双频航向NM7013, 单频下滑NM7031/双频下滑NM7033 四种型号
数据总线
• RMS数据总线 • 对RMS并行数据总线的主要功能是连续地从监控器MO1212A低频信 号产生单元LF1223A和发射控制单元TCA1218A/B收集数据,并通 过该总线对MO1212A监控器告警门限和延迟进行设置,对低频产生 器LF1223A设置发射机参数,以及从发射机控制组件TCA1218A/B 中读取系统状态。同时,向TCA1218A/B写入警告状态也要通过 RMS数据总线实现。
三、NM7000设备机柜配置
NM7000设备机柜配置
• • • • • • • • PS1227A板(电源分配单元)×2块 MF1211A板(监控器前置解调板) ×2块(或MF1219) OS1221A板(晶振单元)×2块 MO1212A板(监控数据处理板) ×2块 TCA1218A板(发射控制板)×1块 LF1223A板(低频信号产生单元板) ×2块 RMA1215A板(RMS系统控制板) ×1块 COA1207B板(发射转换以及SBO 衰减、相位调整单元)×2块 LPA1230/GPA1230板(发射、调 制单元)×2
相关主题
  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
2.点按壁纸后,点按当前壁纸。
3.选择您喜欢的动态图片后,点按设置壁纸。
设置屏幕亮度
1.在应用程序菜单中,点按设置>声音和显示>亮度。
2.滑动调节亮度,点按确定保存设置。
设置屏幕待机时间
您可以设置屏幕待机时间,调整屏幕自动关闭前的延迟时间。
1.在应用程序菜单中,点按设置>声音和显示>屏幕待机。
2.点按您选择的待机时间,完成设置。
(3)取出存储卡:向下轻轻按MicroSD卡,MicroSD卡会自动弹出,再取出MicroSD卡。
推荐使用原厂标配的MicroSD卡或SanDisk、Kingston等主流知名品牌的MicroSD卡,使用某些自购MicroSD卡可能会存在与本机不兼容的问题。请购买前先确认兼容。
MicroSD卡属于微小物体,请不要让儿童接触MicroSD卡,以免儿童将其误吞入口中!
PUK与PUK2码可能随SIM卡一起提供,如果连续3次输入错误的PIN/PIN2码,本机将要求您提供PUK/PUK2码。如果没有该码,请与无线服务运营商联系。
如果连续输入三次错误的PIN码,SIM卡将被锁住,请立即与网络运营商联络以寻求协助解码。自行尝试解码可能导致该SIM卡永久失效。
3.
快速使用指南将帮助您尽快熟悉您的智能终端,并进行一些基本操作。
从拨号盘
1.点按应用程序托盘>拨号应用,进入拨号盘屏幕。
2.在屏幕键盘上,输入您想要拨打电话号码,如果点按 开始拨号。
输入号码过程中,可点按 ,删除错误号码。

1.点按应用程序托盘>拨号>联系人或 直接点按联系人。
2.选择想拨打的联系人,进入联系人信息菜单。
3. 点按号码行 进行呼叫。

1.点按应用程序托盘>拨号>通话记录。
安全设置
恢复出厂值
1.在应用程序菜单中,点按设置>恢复出厂值>恢复出厂设置。
2.点按重置aigoPad。
3.点按清除全部内容,本机重新启动并恢复出厂设置。
主屏幕设置
本机共有五个主屏幕,向左或向右滑动可进行相互切换。在任意界面按下主屏键均可返回到主屏幕。
您可以根据您的需要在主屏幕上添加快捷方式、窗口小部件、文件夹和壁纸。
长按电源键,点按本机选项菜单中的静音模式,可快速开启静音模式。
屏幕设置
设置壁纸
1.在主屏幕界面中,按【菜单键】,打开菜单选项。
2.点按壁纸后,点按壁纸图库,当前壁纸或图库。
3.拖动壁纸缩略图,选择您喜欢的图片,点按设置壁纸。
动态壁纸
您还可以将本机屏幕设置为动态壁纸。
1.在主屏幕界面中,按【菜单键】,打开菜单选项。
耗尽请及时充电,过度放电会损害电池。
智能机在充电期间有轻微发热为正常现象。
此产品只支持使用专用充电器充电,使用其它PC或笔记本电脑不能对此产品完全充电。
此产品低电关机之后,需要充电5-10分钟之后才可以开机,此问题属正常现象。
开机和关机
确认本机中有电池,并且电池有足够电量,按住【电源键】约3秒,可进行开机或关机操作。
主屏幕
您可以通过触摸屏的操作来使用本机的各项功能。本机共有五个主屏幕,向左或向右划动可进行相互切换。在任意界面长按【主页键】可返回到主屏幕。点按主屏幕上的程序图标,即可打开该程序。点按应用程序托盘可以查看全部程序。
屏幕上的图标可以根据您的需要自由增减,详见本机基本设置。
状态栏图标
图标
描述
CDMA网络信号
删除主屏幕上的图标
1.在主屏幕界面中,点按住要删除的图标,直至主屏幕底部显示图标 ,将要删除的图标拖动至 ,删除该图标。
5.
使用浏览器可以使您的智能机访问网页和基于网络的应用程序。如果需要,请向您的网络服务供应商咨询如何连接。
网络连接类型取决于您的网络服务供应商。使用不同的连接类型,您的网络连接费用也有所不同,具体资费详情请咨询您的网络服务供应商。
- 不要暴露在60 C(140 F)以上温度的环境内。
- 只能使用产品指定的电池进行更换。
- 请正确处理电池,不要随意丢弃。
安装UIM/SIM卡:
(1)按照图示方向将UIM/SIM插入卡槽(注意卡缺角方向,不要放反)。
安装存储卡
安装存储卡来扩展其他存储空间(本机使用MicroSD记忆卡)。
(2)安装存储卡:将MicroSD卡有金色触点的一面朝下,按照图示方向,插入卡槽,向下轻轻按直到听到“咔”声。
安装UIM/SIM卡和电池
在安装或取出UIM/SIM卡之前,请确认本机电源已经关闭。
在使用过程中插拔UIM/SIM卡,为保护UIM/SIM卡,系统将做自动关机处理!
UIM/SIM卡由服务提供商提供,它可以储存一些基本数据,比如联系人姓名和电话号码等。注意某些UIM/SIM卡可能和本机不匹配,请咨询
使用旅行充电器为电池充电:
(4)将USB数据线与旅行充电器连接。
把数据线的接口连接到本机的Mini USB接口,并将旅行充电器接到标准电源插座。
(5)正常充电时,电池状态图标 将滚动显示。充电结束显示满格状态。
(6)充满后,请及时切断充电器与交流电源的连接,然后再断开与设备的连接。
新电池初始几次使用,请在连续几次完全充放电以后,再连续10小时以上,以达到最佳性能。
服务提供商进行替换。
本机中包含有原装锂电池,不要试图打开或者维修该电池。电池的使用情况受多种因素影响,包括网络配置、信号强度、操作设备时的环境温度、使用的语音或数据通信以及其他程序使用情况。
为了避免自行着火和燃烧:
- 不要自行打开或维修电池。
- 不要分解、挤压、刺穿电池,不要短接电池外部的接头,更不要将其投入火中或者水中。
1.
2.
正面图
底面图
顶部图
侧面图
背面图
按键
功能描述
电源键:长按3秒用于开机和关机;开机状态下短按可关闭屏幕背光。
音量键:通话时调节通话音量;待机状态调节本机音量。
主页键:在任何界面下点击,退出功能,回到待机界面;在任何界面下长按,出现最近使用的6个菜单选项。
选项键:点击获取更多选项。
返回键:点击返回到上一级菜单
用户使用手册
欢迎:
欢迎您选择使用本机,您可以通过阅读本手册,全面的了解本机的使用,领略其完善的功能和简介的操作方法。
声明:
本手册仅作为产品使用指导,并不代表对产品软硬件配置的说明,产品和配件可能因地区而异。
本机适用于CDMA1X/CDMA2000/EVDO网络环境,某些功能需要网络运营商或服务提供商的支持,详细请参见用户手册相关内容。
在主屏幕界面点击应用程序托盘,您可以访问所有的程序并对系统进行设置。
点击主屏幕托盘,您可以返回主屏幕界面。
您可以设置日期、时间、时区和格式。
在应用程序界面,点按设置>日期和时间。
日期和时间设置包括:自动,设置日期,选择时区,设置时间,使用24小时格式,选择日期格式。
自动选项在插入UIM/SIM卡后才能使用。
在应用程序菜单中,点按浏览器。
打开浏览器后,有以下图标:
往前:点按此键可浏览该窗口前面的网页。
往后:点按此键可浏览该窗口后面的网页。
切换和管理窗口:点按此键可切换和管理打开的所有窗口;点按新窗口,可新建窗口。再次点按此键可以关闭切换窗口界面。
收藏夹:可收藏喜爱的网页并按新闻,游戏和音乐等分类。再次点按此键可以关闭收藏夹界面。
4.
当您需要编辑文本时,可以使用搜狗输入法、Android 键盘、录易手写输入法和谷歌拼音输入法来编辑中文、英文、数字、符号等文本,如添加联系人信息,编辑信息等。
切换输入法:
1. 打开文本编辑界面。
2. 点按住文本编辑区,弹出编辑文字菜单。
3. 点按输入法,在输入法菜单中点按要使用的输入法。
声音设置
本机支持蓝牙无线连接,您可以建立本机与蓝牙耳机配件、免提车载通话设备、计算机或其他设备的无线连接以实现数据交换。
接听来电
当有电话呼入时,向右拖动绿色接听键接听电话,或向左拖动红色挂断键拒绝接听电话。
查看未接来电
若有未接来电,屏幕会在状态行显示一个未接来电图标 。向下滑动状态行,即可查看未接电话。
也可点按应用程序托盘>拨号>通话记录,查看未接来电。
您可以发送和接收短信息或包含多媒体文件的彩信。
点按应用程序托盘>信息可进入信息功能。
1.关闭屏幕
您可以按【电源键】关闭屏幕以节省电量,防止误按。
2.开启屏幕
要开启屏幕,按电源键即可点亮屏幕。
为防止意外操作,您可以对设备和屏幕进行锁定。
1.锁定设备
短按【电源键】,请注意,若您在系统默认或者设定的锁屏时间之内对设备没有任何操作,设备将被自动锁定。
2.解锁设备
短按【电源键】,向右划动主屏中的解锁键解锁。
环保回收:请勿焚烧设备电池或把电池作为普通垃圾处理。请遵守当地环保政策。
连接:需要与其他设备连接时,请仔细阅读设备说明书以确保安全。
儿童安全:请将本机、电池、一些小的部件等放置在儿童难以触及的地方,以免发生危险。
资料备份:请备份设备中存储的重要信息,以防丢失。
SOS:确保设备开机并处于服务区,拨打紧急号码,并告知您的位置。
您可以将您喜欢的Biblioteka 能机铃声设置为来电铃声。铃声设置
1.在应用程序菜单中,点按设置>声音和显示>aigoPad铃声。
2.上下拖动铃声列表,点按铃声名称可以进行试听,选定您喜欢的铃声后,点按确定,保存铃声设置。
将歌曲设为铃声
您也可以将本机内存卡上的歌曲设置为来电铃声。
1.在应用程序菜单中,点按音乐>歌曲。
2. 滚动到您想要呼叫的电话号码或联系人的名字,点按 进行呼叫。
从收藏中拨打电话
相关文档
最新文档