Innova陶瓷屋顶解决方案产品说明书
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
INNOVA
SOLUTIONS
Single H fi re supports that allow the tiles to
be fi red individually at high temperatures,
obtaining perfect defi nition.
H-Selection is the result of applying modern manufacturing processes in H-Cassette to a selection of our products, endowing them with numerous functional and aesthetic advantages and benefits.
Excellent flatness Individual curing of each tile thanks to support in H. Excellent flatness with no contact points.
Lifetime
warranty
Our 100 years of warranty
ensure your peace of
mind and demonstrate
the quality of our
manufacturing process. High definition on
each piece
It provides a perfect
definition on each
piece, made with
gypsum moulds,
providing a much
finer texture.
Low
absorption
Higher resistance
to ice and mould
formation.
PERFECTION IS TO REACH THE TOP. La Escandella stands once again by the latest technology, heavily investing in a new production line designed to optimize the finish of its products and creating a Premium product range. Discover the new H-Selection line, made for excellence.
Double interlocking
The double interlocking
Cost reduction
Its large format (11.5units/m
and strapping every 6 units, as Lower absorption (<5%)
High quality clay together with high fi ring
temperature mean higher resistance to
ice and mildew.
High defi nition on each piece
The gypsum moulds provides a perfect fi nish,
obtaining a smoother texture, no contact points
nor creases.
INNOVA
Ample longitudinal overlapping (80mm)
Avoids cutting the tiles, therefore reducing
FOREFRONT OF DESIGN
FINISHES
TNPK
SLATE KLINKER
TNRK
RED KLINKER
TNCEK
PEPPER KLINKER TNYK
GALAXY KLINKER
Design &
colour variety
TNMK
BROWN KLINKER
Inspiring
Colours
2
OVERLAPPING
· 80mm of longitudinal fit (between 11,5 and 15 pieces per sqm).
· Adaptable for re-roofing on already laid battens (reburbishments)
3
INTERLOCKING
· 45mm interlocking > Large drainage rib.
· Bigger watertightness.
4
TOP INTERLOCKING
· Top interlocking sealed.
· Bigger wattertightness: tiles can be fixed straight on due to the interlocking system.
5
NAIL HOLE
· Pre-hole (easy to be nailed)
· Less tile breakages when nailing.
6
HOOK ATTACHMENT
· Sawtooth.
· Easy hook fixing; one hook allows to fix 3
roof tiles at same time
& ALL IN ONE
LAID METHOD
BROKEN BOND
1.
The starter course will begin with the Q116*K Right side course, continuing with the full tiles to complete the eave. The tiles structuring the eave will have to overlap the side course and fit together one to another . We will finisth the eave with the Q115*K Left side course.
2. The second course will be started again with the Q116*K Right side course, continuing with Half tile Q119*K and will be laid to provide the proper vertical exposure. This exposure is continued through each successive course.
3. All joints of the second course and succeeding courses should be at the center line of the previous course, alternating half tiles (Q119K) and full tiles at the start and at the end of each course.
STRAIGHT BOND
1. The starter course will begin with the Q116*K right side course, continuing with the full tiles to complete the eave. The tiles structuring the eave will have to overlap the side course and fit together one to another . We will finisth the eave with the Q115*K left side course.
2. The second course will be started again installing the Q116*K right side course and doing the same as in step 1.
3. This exposure is continued through each successive course till the ridge.
+20mm First course batten should be 20mm (0.78”) higher than all suceeding course battens to provide a vertical alignment and to assure a symetrical installation.
6mm 6mm / 0.23”
/ 0.23”
Q115*K Innova/Vienna left side course klinker Q116*K Innova/Vienna right side course klinker Q119*K Innova half roof tile klinker
Q115*K Innova/Vienna left side course klinker Q116*K Innova/Vienna right side course klinker
INSTALLATION DETAILS RIDGE
Q01*K | Ridge / Hip klinker
2,600 gr / 5.73 lbs
3 u./lm Q02*K | Round ridge / Hip klinker
3,400 gr / 7.49 lbs 2.5 u./lm Q90*K | Atica ridge 120º klinker
190mm 7.48”
3,600 gr / 7.93 lbs 2.5 u./lm Q03*K | Ridge end / Hip starter klinker
2,900 gr / 6.39 lbs with Q01*K Q04*K | Round ridge end / Hip starter klinker 3,600 gr / 7.93 lbs with Q02*K Q109*K | Atica 120º hip / end ridge klinker 2,900 gr / 6.39 lbs with Q90*K Q120*K | Angular ridge klinker
3,900 gr / 8.6 lbs
2.5 u./lm
*
*
ACCESSORIES
15.75”
17.71”
450mm
17.71”
460mm 18.11”
18.11”250mm 9.84”
245mm 255mm 10.04”
200mm 7.87”
261mm 10.27”
290mm 11.41”
255mm 10.04”
220mm 8.66”
220mm 8.66”
8.46”
*
Q110*K | Atica collar ridge klinker
450mm 17.71”
260mm 10.23”
Q83*K | End cap round ridge klinker
12”
Q05*K | End cap / Straight gable end klinker
Q124*K | Angular end cap klinker
Q122*K | Angular hip / end ridge klinker
with Q120*K
11.22”
250mm
9.84”
*
* 70mm
Q44*K | Round 3 way ridge
klinker 4,600 gr / 10.14 lbs with Q02*K
Ø 440 mm / 17.32
Q121*K | Innova-Vienna Chimney klinker
Q118*K | Innova/Vienna chimney roof tile klinker
465mm 18.3”
255mm 10.04”
Q115*K | Innova/Vienna left side course klinker
2,750 gr / 6.06 lbs
2.5 u./lm 465mm 152mm
5.98”
Q116*K | Innova/Vienna right side course klinker
2,550 gr / 5.62 lbs 2.5 u./lm 465mm 154mm 6.06”
Q117*K | Innova/Vienna ventilation roof tile klinker
465mm 18.3”
10.04”
75mm 2.95”
Q119*K | Innova half roof tile klinker
2,000 gr / 4.4 lbs
465mm 18.3”
150mm 5.9”
Q45*K | Round 4 way ridge
klinker 4,100 gr / 9.04 lbs with
Q02*K Ø 445 mm / 17.52
Q111*K | Atica 120º 3 way ridge klinker
5,100 gr / 11.24 lbs with
Q90*K
480mm /18.9”
470mm /18.5”280mm
11.02”
Q55*K | Round 3 way ridge female klinker 4,100 gr / 9.04 lbs with Q02*K *400mm / 15.75”*442mm / 17.40”
223mm 8.78”
Q123*K | Angular 3 way ridge klinker
with
Q120*K 405mm 15.95”
/ 3.54”
ROOFING COMPONENTS
La Escandella offers a wide range of non-ceramic accessories which help fi nish off any type of roof. From waterprofi ng to ventila-tion, fi xing and batten installing, safety implementation and multiple profi les can be found here. (Ask for wider range in last Price List).
CAM01
Alu-Roll With Micro Cut
CAM21
Waterproof membrane 135 gr/m 2Width: Several sizes
Colours: Red, paja, brown, black.
Dimensions: 1,5 m x 50 m / 1.64 yd x
54.68 yd
CAM08Alu-Flex
CAM27 / CAM70 / CAM07 / CAM10Ridge Tile Hook Width: Several sizes
Colours: Red, paja, brown, black. Colours: Red, brown, black.
CAM09
Alu-Roll Membrane
CAM10
Ridge Batten Bracket Width: Several sizes
Colours: Red, brown, black. Dimensions:
for battens ≤ 4cm / 1.57”
CAM18
Alu-Valley Tape
Width: 50 mm / 1.96”Colours: Red, black.
CAM14
Eaves Ventilation Comb
Dimensions: 6cm x 1m / 2.36” x 39.37”Colours: Red, brown, black.
CAM59 / CAM63
Metal clip for wood battens
CAM64
Metal clip clipped with a bumper
VENTILATION
Ventilation is one of key elements to assure a good hygrother-mal behavior of the roof and preservation of the roof structure. The key to a good and well preserved roof is a good ventila-ted roof. Proper installation of Ventilation tiles combined with ventilated roof can result in energy savings, in a more energy efficient home.
Air should be able to flow through the eave and ridge; be sure not to close these off with cement, mortar or similar . Eave and ridge areas should be protected to help minimize the access of birds and vermin infiltration.
A free flowing ventilation area must be provided through the roof deck. This ventilation should be evenly distributed throu-ghout the roof space to eliminate any dead air space.
La Escandella recommends a minimum of 1 Flat/Alicantina ventilation tile (Q117K) for every 7 m 2 (1.32 vent tiles per 100 sq ft.) and with a minimum of 2 ventilation tiles per roof surface, installed on the upper part of the roof.
Using a proper ventilation system is the best way to avoid moisture in a roof, that could cause peeling, cracking and other defects on the tile.
1. Roof tile
2. Micro-ventilation void
3. Ventilation roof tile
4. Rafter
5. Heat insulation underlayment
6. Waterproof
underlayment material 7. Frame
8. Eaves ventilation comb / bird stop 9. Attic
1
23
3
4
5
5667
7
89
2
18
NON-VENTILATED ROOF
VENTILATED
ROOF
FIXATION
The manner in which roof tiles are installed makes them a hi-ghly effective water shedding assembly that affords years of service and protection. The effectiveness of a tile roof system as a weather resistant assembly however depends on the pro-per installation of all the tile roof components, and installing them properly is critical to the performance of the installed system.
A: Every tile should be securely fastened (Nailed, screwed, cli-pped...) (60º / 203/4:12).
B: As a minimum, each tile in every five proportion, should be secured with (10 gauge) non-corrosive ring shank nails or screws (45º / 12:12).
C: Each tile hangs on the batten (held by the nib) (38º / 10:12).D: Each tile hangs on the batten, held by the nib. When mortar is used, back bed and face point with color matched mortar . Clean off all excess mortar from the face of the tiles. For Foam Adhesive, refer to local building codes.
E: La Escandella recommended minimum slope requirements is 30% (4:12).
A: 60º - 173%B: 45º - 100%
C: 38º - 80%D: 14º - 25%E: 0º - 0%
A
B C D
0º - 0%
90º - 200%
TECHNICAL INFORMATION
SLOPES / PITCHES
The minimum pitch standard recommendations should always be followed (see values in the referral table). On all pitches below the standard recommended minimums, or in regions where ice dams may occur, a waterproof underlayment on the entire deck MUST be ap-plied. Most problems with water-shedding roof installations occur from water that migrates through the joints of the tiles through capillar-ity action, wind-driven rain, and runoff or ice damming. Because of this possibility, the underlayment is critical to the success of the roof.
Note: For hips MORE than 12m long (39.4’), a waterproof underlayment on the entire roof deck MUST be applied and the ventilation underneath must be reinforced (check with the manufacturer).
PROTECTED LOCATIONS: hollow area which is surrounded by hills that protect the hollow from the winds in all directions..NORMAL LOCATIONS:: Flat area, plateau with minimal elevation changes.
EXPOSED LOCATIONS: Places open to strong winds, coastal areas (up to 5 km / 3 miles from the shoreline), islands or narrow peninsulas, estuaries or closed bays, narrow valleys, isolated mountains, mountain passes and earthquake zones.
Protected Normal Exposed Protected Normal Exposed Protected Normal Exposed
WITHOUT UNDERLAYMENT 25% / 14º25% / 14º33% / 18,5º26% / 15º28% / 16º35% / 19,5º27% / 15,5º32% / 18º42% / 23º
27% / 15,5º30% / 17º40% / 22º30% / 17º36% / 20º43% / 23,5º35% / 19,5º40% / 22º50% / 26,5º
25% / 14º27% / 15,5º37% / 20,5º28% / 16º32% / 18º39% / 21,5º30% / 17º35% / 19,5º45% / 24,5º
Protected Normal Exposed Protected Normal Exposed Protected Normal Exposed
Hip < 6,5 m
Hip
6,5 m - 9,5 m
Hip 9,5 m - 12 m
WITH UNDERLAYMENT 23% / 13º23% / 13º31% / 17,5º24% / 13,5º26% / 14,5º33% / 18,5º25% / 14º30% / 17º40% / 22º
25% / 14º28% / 16º38% / 21º30% / 17º32% / 18º42% / 23º32% / 18º37% / 20,5º47% / 25º
23% / 13º25% / 14º35% / 19,5º26% / 14,5º28% / 16º37% / 20,5º27% / 15,5º33% / 18,5º43% / 23,5º
Colour Shall be Harmonized but clay tiles are a natural product and some shade variations between individual pieces enhance their beauty and should be expected. All Tiles should be blended。