IRM-8751-1中文资料

合集下载

克罗韦尔 875 电容式接近传感器技术 数据表

克罗韦尔 875 电容式接近传感器技术 数据表

Technical DataOriginal Instructions875 Capacitive Proximity SensorsBulletin Number 875F, 875LSummary of ChangesThis publication contains the following new or updated information. This list includes substantive updates only and is not intended to reflect all changes.Topic Page875L DC Tubular IO-Link Capacitive Proximity Sensors2875L AC Tubular Capacitive Proximity Sensors6875F DC Rectangular Capacitive Proximity Sensors9Topic PageAdded product photos and updated 875L DC Tubular IO-Link Capacitive Proximity Sensors specification table2Added product photos to 875L AC Tubular Capacitive Proximity Sensors specification table6Updated Product Selection table7Added product photos to 875F DC Rectangular Capacitive Proximity Sensors specification table92Rockwell Automation Publication 875-TD001C-EN-P - October 2022875L DC Tubular IO-Link Capacitive Proximity SensorsSpecificationsAttributeValue Housing materialPlastic PBTRated operating distance (Sn)•875L-M8xx 18 (flush type): 0…8 mm (0…0.31 in.); adjustable distance 2…10 mm (0.08…0.39 in.)•875L-N12xx 18 (non-flush type): 0…12 mm (0…0.47 in.); adjustable distance 3…15 mm (0.12…0.59 in.)•875L-M16xx 30 (flush type): 0…16 mm (0…0.63 in.); adjustable distance 2…20 mm (0.08…0.79 in.)•875L-N25xx 30 (non-flush type): 0…25 mm (0…0.98 in.); adjustable distance 4…30 mm (0.16…1.18 in.)SensitivityAdjustable by potentiometer, external teach or by IO-Link settings •Potentiometer disabled •Potentiometer enabled •External teachFactory settings: Potentiometer enabled Effective operation distance (Sr)0.9 x Sn ≤ Sr ≤ 1.1 x Sn Usable operation distance (Su) 0.85 x Sr ≤ Su ≤ 1.15 x Sr Switching frequency 50 Hz Repeat accuracy (R)≤5%Hysteresis (H)Adjustable by IO-Link (1…100%)•875L-M8xx 18 factory settings: Typical 6%•875L-N12xx 18 factory settings: Typical 15% •875L-M16xx 30 factory settings: Typical 7%•875L-N12xx 18 factory settings: Typical 15%Rated operational volt (UB)10…40V DC (ripple included)Ripple≤10%Rated operating current (Ie) ≤200 mA (continuous)No load supply current (Io)≤20 mA Rated insulation voltage (UI)50V DC Power-ON delay (tv)≤300 ms Operational current (Im), min >0.5 mAVoltage drop (Ud)≤1.0V DC @ 200 mA DC Protection •Short circuit •Reverse polarity •Transients Power ON delay ≤300 ms Degree of protection•IP67•IP68/60 min•IP69K (NEMA 1, 2, 4, 4X, 5, 6, 6P, 12)•ECOLABTemperature •Operating: -30…+85 °C (-22…+185 °F)•Storage: -40…+85 °C (-40…+185 °F)Humidity rangeOperating and storage: 35…95%DC Micro Quick Disconnect Style18 mm and 30 mm Shielded and UnshieldedDC Cable Style 18 mm and 30 mm Shielded and UnshieldedRockwell Automation Publication 875-TD001C-EN-P - October 20223875 Capacitive Proximity Sensors Technical Data875L DC 18 mm (0.71 in.) Diameter SensorsProduct SelectionApproximate DimensionsDimensions are shown in mm (in.). Dimensions are not intended to be used for manufacturing purposes.Cat. No. (1)(1)All units come with two nuts to secure the unit on the mounting bracket.Barrel DiameterShieldedOutput Polarity ConnectionWiring DiagramDimensions875L-M8NP18-A218 mm (0.71 in.)YesN.O.PNP 2 m (6.6 ft) PVC cableFigure 10 on page 5Figure 1875L-M8NN18-A2NPN Figure 12 on page 5875L-M8CP18-A2N.C.PNP Figure 9 on page 5875L-M8CN18-A2NPN Figure 11 on page 5875L-M8NP18-D4N.O.PNP M12 Micro QDFigure 10 on page 5Figure 2875L-M8NN18-D4NPN Figure 12 on page 5875L-M8CP18-D4N.C.PNP Figure 9 on page 5875L-M8CN18-D4NPN Figure 11 on page 5875L-N12NP18-A2NoN.O.PNP 2 m (6.6 ft) PVC cableFigure 10 on page 5Figure 3875L-N12NN18-A2NPN Figure 12 on page 5875L-N12CP18-A2N.C.PNP Figure 9 on page 5875L-N12CN18-A2NPN Figure 11 on page 5875L-N12NP18-D4N.O.PNP M12 Micro QDFigure 10 on page 5Figure 4875L-N12NN18-D4NPN Figure 12 on page 5875L-N12CP18-D4N.C.PNP Figure 9 on page 5875L-N12CN18-D4NPNFigure 11 on page 5Figure 1 - Shielded 18 mm (0.71 in.) with Cable [mm (in.)]Figure 2 - Shielded 18 mm (0.71 in.) with M12 Micro QD [mm (in.)]Figure 3 - Unshielded 18 mm (0.71 in.) with Cable [mm (in.)][mm(in.)]4Rockwell Automation Publication 875-TD001C-EN-P - October 2022875 Capacitive Proximity Sensors Technical Data875L DC 30 mm (1.81 in.) Diameter SensorsProduct SelectionApproximate DimensionsDimensions are shown in mm (in.). Dimensions are not intended to be used for manufacturing purposes.Cat. No. (1)(1)All units come with two nuts to secure the unit on the mounting bracket.Barrel DiameterShieldedOutput Polarity ConnectionWiring DiagramDimensions875L-M16NP30-A230 mm (1.81 in.)YesN.O.PNP 2 m (6.6 ft) PVC cableFigure 10 on page 5Figure 5875L-M16NN30-A2NPN Figure 12 on page 5875L-M16CP30-A2N.C.PNP Figure 9 on page 5875L-M16CN30-A2NPN Figure 11 on page 5875L-M16NP30-D4N.O.PNP M12 Micro QDFigure 10 on page 5Figure 6875L-M16NN30-D4NPN Figure 12 on page 5875L-M16CP30-D4N.C.PNP Figure 9 on page 5875L-M16CN30-D4NPN Figure 11 on page 5875L-N25NP30-A2NoN.O.PNP 2 m (6.6 ft) PVC cableFigure 10 on page 5Figure 7875L-N25NN30-A2NPN Figure 12 on page 5875L-N25CP30-A2N.C.PNP Figure 9 on page 5875L-N25CN30-A2NPN Figure 11 on page 5875L-N25NP30-D4N.O.PNP M12 Micro QDFigure 10 on page 5Figure 8875L-N25NN30-D4NPN Figure 12 on page 5875L-N25CP30-D4N.C.PNP Figure 9 on page 5875L-N25CN30-D4NPNFigure 11 on page 5Figure 5 - Shielded 30 mm (1.81 in.) with Cable [mm (in.)]Figure 6 - Shielded 30 mm (1.81 in.) with M12 Micro QD [mm (in.)]Rockwell Automation Publication 875-TD001C-EN-P - October 20225875 Capacitive Proximity Sensors Technical Data875L DC Wiring DiagramsFigure 9 - Sourcing N.C.Figure 10 - Sourcing N.O.Figure 11 - Sinking N.C.Figure 12 - Sinking N.O.875L AC Tubular Capacitive Proximity SensorsSpecificationsAttribute ValueHousing material Plastic PBTRated operating dist. (Sn)•875L-F8x18: 3…8 mm (0.12…0.31 in.) - factory set at 8 mm (0.31 in.)•875L-G12x18: 3…12 mm (0.12…0.47 in.) - factory set at 12 mm (0.47 in)•875L-F16x30: 2…16 mm (0.08…0.63 in.) - factory set at 16 mm (0.63 in.)•875L-G25x30: 4…25 mm (0.16…0.98 in.) - factory set at 25 mm (0.98 in.)Sensitivity270° turn potentiometer (adjustable) Effective operation distance (Sr)0.9 x Sn ≤ Sr ≤ 1.1 x SnUsable operation distance (Su)0.8 x Sr ≤ Su ≤ 1.2 x Sr Switching frequency10 HzRepeat accuracy (R)≤5%Hysteresis (H)4…20% of sensing distance Rated operational volt (UB)20…250V AC (ripple included) Ripple≤10%Rated operating current (Ie)•Continuous: ≤500 mA •Short-time: <2.5 A (20 ms, max)Load current, min10 mAVoltage drop (Ud)≤10V AC (at loads ≥20 mA) Protection TransientsPower ON delay≤100 msFrequency of operating cycles (f)10 HzIndication for output ON Yellow status indicator Degree of protection IP67 (NEMA 1, 3, 4, 6, 13)Temperature •Operating: -25…+80 °C (-13…+176 °F)•Storage: -40…+85 °C (-40…+185 °F)AC Micro Quick Disconnect Style18 mm and 30 mmShielded and UnshieldedAC Cable Style18 mm and 30 mmShielded and Unshielded6Rockwell Automation Publication 875-TD001C-EN-P - October 2022Rockwell Automation Publication 875-TD001C-EN-P - October 20227875 Capacitive Proximity Sensors Technical Data875L 2-wire AC 18 mm (0.71 in.) and 30 mm (1.81 in.) Diameter SensorsProduct SelectionApproximate DimensionsDimensions are shown in mm (in.). Dimensions are not intended to be used for manufacturing purposes.Cat. No. (1)(1)All units come with two nuts to secure the unit on the mounting bracket.Barrel DiameterShieldedOutput Connection Wiring Diagram Dimensions 875L-F8N18-A218 mm (0.71 in.)YesN.O. 2 m (6.6 ft) PVC cableFigure 21 on page 8Figure 13875L-F8C18-A2N.C.Figure 22 on page 8875L-F8N18-R3N.O.AC Micro QD Figure 21 on page 8Figure 14875L-F8C18-R3N.C.Figure 22 on page 8875L-G12N18-A2NoN.O. 2 m (6.6 ft) PVC cableFigure 21 on page 8Figure 15875L-G12C18-A2N.C.Figure 22 on page 8875L-G12N18-R3N.O.AC Micro QD Figure 21 on page 8Figure 16875L-G12C18-R3N.C.Figure 22 on page 8875L-F16B30-A230 mm (1.81 in.)YesN.O. or N.C. 2 m (6.6 ft) PVC cableFigure 23 on page 8Figure 17 on page 8875L-F16B30-R3AC Micro QD Figure 23 on page 8Figure 18 on page 8875L-G25B30-A2NoN.O. or N.C.2 m (6.6 ft) PVC cableFigure 23 on page 8Figure 19 on page 8875L-G25B30-R3AC Micro QDFigure 23 on page 8Figure 20 on page 8Figure 13 - AC Shielded 18 mm (0.71 in.) with Cable [mm (in.)]Figure 14 - AC Shielded 18 mm (0.71 in.) with AC Micro QD [mm (in.)]Figure 15 - AC Unshielded 18 mm (0.71 in.) with Cable [mm (in.)]Figure 16 - AC Unshielded 18 mm (0.71 in.) with AC Micro QD[mm (in.)]71.5 (2.81)15.5(0.61)Status IndicatorSW 24Sensit 8(0.31)6 (0.24)25 (0.98)2000 (78.74)46.5 (1.83)52.3 (2.06)M18 X 1Ø 10(0.39)Ø 5.2(0.2)1/2 - 20 UNFM18 X 1Status IndicatorSensitSW 246(0.24)46.5 (1.83)52.3 (2.06)69.3 (2.73)14.2(0.56)22.8 (0.9)Status IndicatorSensitSW 2471.5 (2.81)6(0.24)25 (0.98)2000 (78.74)46.5 (1.83)52.3 (2.06)15.5(0.61)Ø 10(0.39)Ø 5.2(0.2)8(0.31)8(0.31)M18 X 1Status Indicator1/2 - 20 UNFSensitSW 248(0.31)M18 X 16(0.24)46.5 (1.83)52.3 (2.06)69.3 (2.73)14.2(0.56)22.8(0.9)8(0.31)8Rockwell Automation Publication 875-TD001C-EN-P - October 2022875 Capacitive Proximity Sensors Technical DataApproximate DimensionsDimensions are shown in mm (in.). Dimensions are not intended to be used for manufacturing purposes.875L 2-wire AC Wiring DiagramsFigure 17 - AC Shielded 30 mm (1.81 in.) with Cable [mm (in.)]Figure 18 - AC Shielded 30 mm (1.81 in.) with AC Micro QD [mm (in.)]Figure 19 - AC Unshielded 30 mm (1.81 in.) with Cable [mm (in.)]Figure 20 - AC Unshielded 30 mm (1.81 in.) with AC Micro QD[mm (in.)]Figure 21 - Wiring Diagram - Sourcing N.O.Figure 22 - Wiring Diagram - Sourcing N.C.Figure 23 - Wiring Diagram - N.C. or N.O. Selectable50(1.97)10 (0.39)Status Indicator M30 X 1.5 X 5013.6(0.54)15.4(0.61)Ø 36(1.42)Ø 28(1.1)Status Indicator10 (0.39)M30 X 1.5 X 50Ø 36(1.42)1/2 - 20 UNFØ 28(1.1)50(1.97)13.6(0.54)15.4(0.61)Status Indicator 62(2.44)Ø 28(1.1)Ø 36(1.42)M30 X 1.5 X 5013.6(0.54)15.4(0.61)10(0.39)12(0.47)Status Indicator 62(2.44)Ø 28(1.1)Ø 36(1.42)M30 X 1.5 X 5013.6(0.54)15.4(0.61)10(0.39)12(0.47)1/2 - 20 UNFRockwell Automation Publication 875-TD001C-EN-P - October 20229875F DC Rectangular Capacitive Proximity SensorsSpecificationsAttributeValue Housing materialPlastic PBTDetection•Pipes diameter: Ø8 mm (0.31 in.), minimum •Wall thickness (factory settings):–Plastic (non-conductive plastic wall): 0.5…6 mm (0.02…0.24 in.)–Glass (non-conductive glass wall): 0.5…4 mm (0.02…0.16 in.)•Wall thickness (manual setup):≤10 mm (0.39 in.) plastic wall (best case)≤10 mm (0.39 in.) glass wall (best case)•Liquids: Water-based liquids such as water, milk, syrup, honey, milkshakes, lubricates, acids, alkaline fluids, body fluids, and other high-conductive liquids (≤50 ms)Effective operation distance (Sr)0.9 x Sn ≤ Sr ≤ 1.1 x Sn Usable operation distance (Su) 0.85 x Sr ≤ Su ≤ 1.15 x Sr Switching frequency ≤10 Hz Repeat accuracy (R)≤5%Hysteresis (H)Adjustable by IO-Link (1… 100%)•875L-M8xx 18 factory settings: Typical 6%•875L-N12xx 18 factory settings: Typical 15%•875L-M16xx 30 factory settings: Typical 7%•875L-N12xx 18 factory settings: Typical 15%Rated operational volt (UB)10…30V DC (ripple included)Ripple≤10%Output functionsNPN or PNP by sensor type Output switching function N.O. and N.C by sensor type Rated operating current (Ie)≤100 mA No load supply current (Io)≤13 mA Rated insulation voltage (UI)75V DC Power-ON delay (tv)≤300 ms Voltage drop (Ud)≤1.5VProtection•Short circuit •Reverse polarity •Transients Degree of protection•IP65•IP66•IP67•*********(4.27ft)and24hr •IP69K (NEMA 1, 2, 4, 4x, 5, 12)•ECOLABTemperature •Operating: -25…+80 °C (-13…+176 °F)•Storage: -40…+85 °C (-40…+185 °F)Humidity rangeOperating and storage: 35…95%Pigtail cable with Integral Micro QD Connector Style34 x 16 x 8 mm ShieldedDC Cable Style 34 x 16 x 8 mm Shielded875F Capacitive Proximity Sensor in Universal Mounting BracketMounting Bracket and Adhesive Pads (Supplied with Sensor)10Rockwell Automation Publication 875-TD001C-EN-P - October 2022875 Capacitive Proximity Sensors Technical Data875F DC Flat Cap SensorsProduct SelectionApproximate DimensionsDimensions are shown in mm (in.). Dimensions are not intended to be used for manufacturing purposes.875F DC Wiring DiagramsCat. No.Sensing DistanceShieldedOutput ConfigurationConnectionWiring Diagram Dimensions875F-M10NP34-A2Out of box wall thickness:Plastic 0.5…6 mm (0.02…0.24 in.)Glass 0.5…4 mm (0.02…0.16 in.)Best Case (Taught) 10 mm (0.39 in.)Yes N.O.PNP2 m (6.6 ft.) PVC cableFigure 27Figure 24875F-M10NN34-A2NPN Figure 29875F-M10CP34-A2N.C.PNPFigure 26875F-M10CN34-A2NPN Figure 28875F-M10NP34-FP02N.O.PNP152 mm (6 in.) PVC cable with M8 pico quick disconnectFigure 27875F-M10NN34-FP02NPN Figure 29875F-M10CP34-FP02N.C.PNPFigure 26875F-M10CN34-FP02NPNFigure 28Figure 24 - SensorFigure 25 - Mounting BracketFigure 26 - Sourcing N.C.Figure 27 - Sourcing N.O.Figure 28 - Sinking N.C.Figure 29 - Sinking N.O.Pin Color Description 1BN (Brown)Supply (V+)2WH (White)Teach input 3BU (Blue)Supply (V-)4BK (Black)OutputIMPORTANTWhen not used, permanently connect the teach wire to V-.1.13416.3 3.6 6.6Rockwell Automation Publication 875-TD001C-EN-P - October 202211875 Capacitive Proximity Sensors Technical DataAdditional ResourcesThese documents contain additional information concerning related products from Rockwell Automation.You can view or download publications at rok.auto/literature .ResourceDescription Capacitive Sensors User Manual, publication 875-UM001Provides guidance on installation, configuration, and use for Bulletin 875F and 875L capacitive proximity sensors with IO-Link.Rectangular Capacitive Sensors Installation Instructions, publication 875F-IN001Describes how to install a rectangular capacitive sensor.System Security Design Guidelines Reference Manual, SECURE-RM001Provides guidance on how to conduct security assessments, implement Rockwell Automation products in a secure system, harden the control system, manage user access, and dispose of equipment.UL Standards Listing for Industrial Control Products, publication CMPNTS-SR002Assists original equipment manufacturers (OEMs) with construction of panels, to help ensure that they conform to the requirements of Underwriters Laboratories.American Standards, Configurations, and Ratings: Introduction to Motor Circuit Design, publication IC-AT001Provides an overview of American motor circuit design based on methods that are outlined in the NEC.Industrial Components Preventive Maintenance, Enclosures, and Contact Ratings Specifications, publication IC-TD002Provides a quick reference tool for Allen-Bradley industrial automation controls and assemblies.Safety Guidelines for the Application, Installation, and Maintenance of Solid-state Control, publication SGI-1.1Designed to harmonize with NEMA Standards Publication No. ICS 1.1-1987 and provides general guidelines for the application, installation, and maintenance of solid-state control in the form of individual devices or packaged assemblies incorporating solid-state components.Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1Provides general guidelines for installing a Rockwell Automation industrial system.Product Certifications website, rok.auto/certifications .Provides declarations of conformity, certificates, and other certification details.Publication 875-TD001C-EN-P - October 2022Supersedes Publication 875-TD001B-EN-P - September 2022Copyright © 2022 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.Rockwell Automation SupportUse these resources to access support information.Documentation FeedbackYour comments help us serve your documentation needs better. If you have any suggestions on how to improve our content, complete the form at rok.auto/docfeedback .Technical Support CenterFind help with how-to videos, FAQs, chat, user forums, Knowledgebase, and product notification updates.rok.auto/support Local Technical Support Phone NumbersLocate the telephone number for your country.rok.auto/phonesupport Technical Documentation CenterQuickly access and download technical specifications, installation instructions, and user manuals.rok.auto/techdocs Literature LibraryFind installation instructions, manuals, brochures, and technical data publications.rok.auto/literature Product Compatibility and Download Center (PCDC)Download firmware, associated files (such as AOP, EDS, and DTM), and access product release notes.rok.auto/pcdc Rockwell Automation maintains current product environmental compliance information on its website at rok.auto/pec .Allen-Bradley, expanding human possibility, and Rockwell Automation are trademarks of Rockwell Automation, Inc.Trademarks not belonging to Rockwell Automation are property of their respective companies.Rockwell Otomasyon Ticaret A.Ş. Kar Plaza İş Merkezi E Blok Kat:6 34752, İçerenköy, İstanbul, Tel: +90 (216) 5698400 EEE Yönetmeliğine Uygundur。

安捷伦科技GC TOF仪器校准剂IRM说明书

安捷伦科技GC TOF仪器校准剂IRM说明书

IRM Calibrant for GC/TOF, Part Number 5190-0531化学品安全技术说明书GHS product identifier 应急咨询电话(带值班时间)::化学名:2,4,6-tris(Pentafluoroethyl)-1,3,5-triazine 供应商/ 制造商:安捷伦科技贸易(上海)有限公司中国(上海)外高桥自由贸易试验区英伦路412号(邮编:200131)电话号码: 800-820-3278传真号码: 0086 (21) 5048 2818IRM Calibrant for GC/TOF, Part Number 5190-0531化学品的推荐用途和限制用途5190-0531部件号:物质用途:供分析化学实验室使用的试剂和标准1 x 0.5 ml(毫升)安全技术说明书根据 GB/ T 16483-2008 和 GB/ T 17519-2013GHS化学品标识:IRM 调谐液,用于 GC/TOF,部件号 5190-0531危险性类别信号词:警告危险性说明:H332 - 吸入有害。

:防范说明预防措施:事故响应:安全储存:不适用。

废弃处置:不适用。

GHS标签要素象形图急性毒性 (吸入) - 类别 4紧急情况概述液体。

清澈。

无资料。

有关环境保护措施,请参阅第 12 节。

H332 - 吸入有害。

物理和化学危险没有明显的已知作用或严重危险。

健康危害吸入有害。

::与物理,化学和毒理特性有关的症状眼睛接触:没有具体数据。

物理状态:颜色:气味:皮肤接触食入没有具体数据。

没有具体数据。

::延迟和即时影响,以及短期和长期接触引起的慢性影响短期暴露潜在的即时效应:无资料。

潜在的延迟效应:无资料。

潜在的即时效应:无资料。

长期暴露潜在的延迟效应:无资料。

环境危害:没有明显的已知作用或严重危险。

其他危害:没有已知信息。

没有出现就供应商当前所知可应用的浓度,被分类为对健康或环境有害及因此需要在本节报告的添加剂。

Omega HANITM 夹钳型传感器产品说明书

Omega HANITM 夹钳型传感器产品说明书

HANI TM 夹钳型传感器 - 应用于工业的高精度,非侵入式夹钳型温度传感器可在集成了 Layer N 连接的金属管上进行混合温度感应•以非侵入式方式测量温度测量金属管内的液体温度 金属管卫生型金属管道精度:±0.5°C 至±1.0°C(±0.9°F 至±1.8°F) 响应时间1 = 5 秒 (t63)/10 秒 (t90) 4 至 20 mA 回路供电模拟输出 0 至 100°C 工艺温度范围 可用于 1.0 至 4.0 英寸管径 (其他尺寸可定制)Omega Smart Core•数据记录•即插即用型设备检测 IP65 环境保护等级正在申请专利• • • • • • • 使用多个传感器和一种专有算法,可在不增加成本和风险的情况下,实现与最先进的侵入式传感器相同的精度和快速响应时间。

质量控制和临时感应只需短短几秒即可夹持传感器并连接到笔记本电脑或 PC方便随时随地读取读数。

• • 易于安装只需短短几秒即可安装 HANI ™ 夹钳型传感器Omega 创新的夹钳式设计使传感器安装变得十分简单。

与侵入式传感器不同,HANI ™ 夹钳型传感器安装在金属管的外侧,可测量管道内工艺介质的温度。

•无需钻孔•无需焊接•无需停机需要重新定位传感器?松开夹钳即可!验证现有的侵入式传感器HANI ™ 夹钳型传感器的精度可与大多数先进的有侵入式传感器相媲美,能够轻松与侵入式传感器 结合使用,以核实侵入式传感器的精度或确定其漂移情况。

常见应用新系统和改造现有系统升级至 HANI ™ 夹钳型传感器,可在不影响性能的前提下降低总拥有成本和污染风险。

响应时间曲线50 45非侵入式和无接触操作无渗透,无污染风险HANI ™ 夹钳型传感器绝对不会接触流经管道的工艺介质。

不存在因高流速、腐蚀性/磨蚀性液体、伴流频率和水锤现象造成的堆积、传感器磨损或破损风险。

JM875 AC Current Probe模型的用户指南说明书

JM875 AC Current Probe模型的用户指南说明书

®I N S T R U M E N TSAC Current Probe Model JM875User ManualDESCRIPTIONThe JM875 (Catalog #2110.89) is designed for use in industrial environments. The “squared” jaws permit multiple conductor or bus bar positioning. The voltage output makes it the perfect tool for measurement with DMMs, recorders, power and harmonic meters. Three ranges allow you to obtain the best resolution even on low current measurement. The Model JM875 is compatible with any AC voltmeter, multimeter, or other voltage measuring instrument with an input impedance greater than 1 M . To achieve the stated accuracy, use the JM875 with a voltmeter having an accuracy of 0.75%.WARNINGThese safety warnings are provided to ensure the safety of personnel and proper operation of the instrument.•Read the instruction manual completely and follow all the safety information before attempting to use or service this instrument. •Use caution on any circuit: Potentially high voltages and currents may be present and may pose a shock hazard. •Read the Safety Specifications section prior to using the current probe. Never exceed the maximum voltage ratings given.• Safety is the responsibility of the operator.•ALWAYS connect the current probe to the display device before clamping the probe onto the sample being tested. •ALWAYS inspect the instrument, probe, probe cable, and output terminals prior to use. Replace any defective parts immediately. •NEVER use the current probe on electrical conductors rated above 600 V in overvoltage category III (CAT III). Use extreme caution when clamping around bare conductors or bus bars. INTERNATIONAL ELECTRICAL SYMBOLSThis symbol signifies that the current probe is protected by double or reinforced insulation. Use only factory specified replacement parts when servicing the instrument.This symbol signifies CAUTION! and requests that the user refer to the user manual before using the instrument.This is a type A current sensor. This symbol signifies that application around and removal from HAZARDOUS LIVE conductors is permitted.DEFINITION OF MEASUREMENT CATEGORIESCat. II: For measurements performed on circuits directly connected to the electrical distribution system.Examples are measurements on household appliances or portable tools. Cat. III: For measurements performed in the building installation at the distribution level such as onhardwired equipment in fixed installation and circuit breakers.Cat. IV: For measurements performed at the primary electrical supply (<1000V) such as on primaryovercurrent protection devices, ripple control units, or meters. RECEIVING YOUR SHIPMENTUpon receiving your shipment, make sure that the contents are consistent with the packing list. Notify your distributor of any missing items. If the equipment appears to be damaged, file a claim immediately with the carrier and notify your distributor at once, giving a detailed description of any damage .ELECTRICAL SPECIFICATIONS Current Range:100mA to 30A AC continuous cycle1 to 300A AC continuous cycle1 to 2000A AC continuous cycle for the full temperature range(2800 A if temperature is < 35°C or 95°F) Output Signal:100mV AC/A AC (3V at 30A) 90A peak10mV AC/A AC (3V at 300A) 900A peak 1mV AC/A AC (3V at 3000A) 9000A peak Accuracy and Phase Shift*:30A RANGEPrimary current 1.5A 6A 30A Accuracy % 2% ± 10mV (0.5A) Phase shift 15° 7° 5° Probe Impedance: 1000Ω300A RANGEPrimary current 15A 60A 300A Accuracy % 2% ± 2mV (0.2mA) Phase shift 3° 1.5° 1° Probe Impedance: 100Ω3000A RANGEPrimary current 150A 600A 3000A Accuracy % 2% ± 0.5 mV Phase shift 1.5° 1° 0.5° Probe Impedance: 10Ω(*Reference conditions: 23°C±3°K, 20 to 85% RH, 48 to 65 Hz, external magnetic field < 40 A/m, no DC component, no external current carrying conductor, test sample centered.) Load impedance ≥ 1 MΩ.Overload: 3200 A during 5 mnAccuracy: Per IEC 185-26-27Ampere Second Product: 100 A.sdV/Dt: 100 mV AC/A AC: dV/Dt = 400 mV/µs10 mV AC/A AC: dV/Dt = 50 mV/µs1 mV AC/A AC: dV/Dt - 5 mV/µs Frequency Range: 30Hz to 5kHz; current derating above 200Hz on the 3000A range Load Impedance: > 100kΩWorking Voltage: 600V ACCommon Mode Voltage: 600V ACOpen Secondary Voltage: 10V Max. Influence of Adjacent Conductor:0.005A/A ACInfluence of Conductor in Jaw Opening: 1.5% of readingInfluence of Frequency from 30Hz to 5kHz: ± 6% on all rangesInfluence of DC Current: 0.05% per A DCMECHANICAL SPECIFICATIONS Operating Temp.: 14° to 122°F (-10° to 50°C) Storage Temp.: -40° to 185°F (-40° to 85°C) Influence of Temperature: < 0.1% per 10°K Jaw Opening: 3.54" (90mm)Maximum Conductor Size:Cable: 2.52" ∅ max. (64mm)Bus bar: 1.97 x 5.31" (50 x 135mm)2.52 x3.94" (64 x 100mm)Envelope Protection: IP 20 (IEC 529)Drop Test: 500mm (IEC 68-2-32)Mechanical Shock: 100 g (IEC 68-2-27) Vibration: 10/55/10Hz, 0.15 mm (IEC 68-2-6) Polycarbonate Material:Handles:10% fiberglass chargedpolycarbonate UL 94 V0Jaws: ABS UL 94 V2Dimensions:4.72 x 12.40 x 1.89" (120 x 315 x 48 mm) Weight: 2.65 lbs. (1200 g)Colors: Dark gray handles with red jaws Output:Two standard safety banana jacks (4 mm) SAFETY SPECIFICATIONSElectrical:Double insulation or reinforced insulation between primary or secondary and outer case of handle upon IEC 1010-2-32Common Mode Voltage:600V Category III, Pollution: 2ORDERING INFORMATIONCurrent Probe JM875 ........................ Cat #2110.89 Accessories:Leads, set of 2, 5 ft. safety (1000V) .... Cat #2111.29 Lead No. 211 for Probe 5 A Series .....Cat #2950.06OPERATIONPlease make sure that you have already read and fully understand the WARNING section on page 1. Making Measurements with the AC Current Probe Model JM875•Connect the black and red terminals to the Volt AC range of your DMM or voltage measuring instrument. Select the appropriate voltage range. If the current magnitude is unknown, select the highest range (3000A AC / 3V AC) on the switch probe located inside the handle. Clamp the probe around the conductor to be tested. If the reading is less than 300mV or 30mV, select the lower range until you obtain the best resolution. Read the value display on the DMM (in mV) and divide it by the range selected. (If reading = 2.59V on the 10mV AC/A AC range, the current flowing through the probe is 2590mV ÷ 10 = 259A AC).•For best accuracy: carefully center the conductor inside the probe jaw, avoid if possible, the proximity of other conductors which may create noise.Tips for Making Precise Measurements•When using a current probe with a meter, it is important to select the range that provides the best resolution. Failure to do this may result in measurement errors.•Make sure that probe jaw mating surfaces are free of dust and contamination. Contaminants cause air gaps between the jaws, increasing the phase shift between primary and secondary. It is very critical for power measurement.MAINTENANCE:Warning• For maintenance use only original factory replacement parts.• To avoid electrical shock, do not attempt to perform any servicing unless you are qualified to do so.•To avoid electrical shock and/or damage to the instrument, do not get water or other foreign agents into the probe.To ensure optimum performance, it is important to keep the probe jaw mating surfaces clean at all times. Failure to do so may result in error in readings. The following is the recommended procedure for cleaning the probe jaws: Use a very fine sand paper (fine 600) to avoid scratching the jaw, then gently clean with a soft oiled cloth.REPAIR AND CALIBRATIONYou must contact our Service Center for a Customer Service Authorization number (CSA#). This will ensure that when your instrument arrives, it will be tracked and processed promptly. Please write the CSA# on the outside of the shipping container.Chauvin Arnoux®, Inc. d.b.a. AEMC® Instruments15 Faraday Drive Dover, NH 03820 USA(800)945-2362(Ext.360)•(603)749-6434(Ext.360)•***************(Or contact your authorized distributor)NOTE: All customers must obtain a CSA# before returning any instrument.TECHNICAL AND SALES ASSISTANCEIf you are experiencing any technical problems, or require any assistance with the proper use or application of this instrument, please contact our technical hotline:(800) 945-2362 (Ext. 351) • (603) 749-6434 (Ext. 351)•********************LIMITED WARRANTYThe current probe is warranted to the owner for a period of 2 year s from the date of original purchase against defects in manufacture. This limited warranty is given by AEMC®Instruments, not by the distributor from whom it was purchased. This warranty is void if the unit has been tampered with, abused or if the defect is related to service not performed by AEMC® Instruments.Full warranty coverage and product registration is available on our website at:/warranty.html.Please print the online Warranty Coverage Information for your records.99-MAN 100103.v6 02/18。

PCS-9662辅助装置技术说明书(20141202)

PCS-9662辅助装置技术说明书(20141202)
我们保留在不事先通知的情况下进行技术改进的权利。
南京南瑞继保电气有限公司
iii
PCS-9662 辅助装置
目录
前言 .......................................................................................................................................i 目录 .....................................................................................................................................iv 第 1 章 概述........................................................................................................................1
危险!
意味着如果安全预防措施被忽视,则会导致人员死亡, 严重的人身伤害,或严重的设备 损坏。
警告!
意味着如果安全预防措施被忽视,则可能导致人员死亡, 严重的人身伤害,或严重的设 备损坏。
警示!
意味着如果安全预防措施被忽视,则可能导致轻微的人身伤害或设备损坏。本条特别适 用于对装置的损坏及可能对被保护设备的损坏。
2.1.1 直流电源.......................................................................................................3 2.2 机械结构 .................................................................................................................3 2.3 环境条件参数..........................................................................................................3 2.4 型式试验 .................................................................................................................3

twh8751

twh8751

TWH8751/TWH8752引脚功能:
1脚:IN,
2:选通,ST,
3:GND
4:OUT
5:VDD TO-220封装
主要特点:
噪声低,抗干扰性能好,有滞回特性
有过电压、过电流的自我保护
内置6.8V稳压管,可省去外置稳压源
开关频率高,最高可达1.6MHZ
开关特性好,边缘陡峭,边缘延迟为微秒数量级
控制功率大,内置达林顿功率管,反向击穿电压高达100V,输出端为集电极开路输出,最大灌电流可达3-4A
TWH8752与TWH8751的区别:
TWH8752的引脚与TWH8751引脚相同,但是比TWH8751更适合大电流状态下工作。

如图所示是一个采用TW H8751功率开关集成电路构成的光控自动路灯电路,它将TWH8751的输入端第①脚接电源正端,所以输出端④脚状态由选通端即第②脚电平控制。

白天,RP受自然光线照射呈现低电阻,选通端②脚为高电平,所以输出端④脚也为高电平,继电器K不动作,路灯E不亮。

夜晚,RL无光照射呈现高电阻,选通端②脚为低电平,TW H8751内部达林顿管导通,④脚为低电平,继电器K 吸合,其动合触点k-1闭合,路灯E通电发光。

调节RP阻值可以调整电路的光控灵敏度。

R2、C1为干扰脉冲吸收电路,可消除夜间短暂光线对电路的影响。

T可用220V/12V、5VA小型优质电源变压器、K应根据负载大小选择适合的工作电压
为12V的继电器,如JZC-22F、DC12V型等。

8031和8051,8751单片机的区别和特点

8031和8051,8751单片机的区别和特点
由于51系列单片机的内核都一样,所以在51单片机教材方面目前仍然沿用Intel MCS 8051单片机的书籍。开发软件和工具也是一样,我们统称为8051开发系统、环境、等等,如我们网站介绍的汇编程序ASM51、Keil C51、MedWin 等均是针对8051内核单片机的开发软件。
单对AT89C51、AT89S51来说,在实际电路中可以直接互换8051\\8751,替换8031只是第31脚有区别,8031因内部没有ROM,31脚需接地(GND),单片机在启动后就到外面程序存储器读取指令;而8051/8751/89c51因内部有程序存储器,31脚接高电平(VCC),单片机启动后直接在内部读取指令。也就是51芯片的31脚控制着单片机程序从内部读取还是从外部读取,31脚接电源,程序从内部读取,31脚接地,程序从外部读取。其他无须改动。另外,AT89C51、AT89s51替换8031后因不用外存储器,不必安装原电路的外存储器和373芯片。
8031、8051、8751、89C51、89S51的区别与特点
.文章来源:net
8031/8051/8751是Intel公司早期的产品。
8031的特点
8031片内不带程序存储器ROM,使用时用户需外接程序存储器和一片逻辑电路373,外接的程序存储器多为EPROM的2764系列。用户若想对写入到EPROM中的程序进行修改,必须先用一种特殊的紫外线灯将其照射擦除,之后再可写入。写入到外接程序存储器的程序代码没有什么保密性可言。
AT89C51、AT89S51的特点
在众多的51系列单片机中,要算 ATMEL 公司的AT89C51、AT89S51更实用,因他不但和8051指令、管脚完全兼容,而且其片内的4K程序存储器是FLASH工艺的,这种工艺的存储器用户可以用电的方式瞬间擦除、改写,一般专为 ATMEL AT89xx 做的编程器均带有这些功能。显而易见,这种单片机对开发设备的要求很低,开发时间也大大缩短。写入单片机内的程序还可以进行加密,这又很好地保护了你的劳动成果。再着,AT89C51、AT89S51目前的售价比8031还低,市场供应也很充足。

测度875系列热像仪说明书

测度875系列热像仪说明书

875-1I875-2I875-1Thermal imagertesto 875 and testo 875i –the entry into professionalthermographyWe measure it.testo 875 / testo 875iFunctionof the PC software: Image overlay TwinPixExchangeable lensesSolar modeFor each measurement, the sun irradiation value can be entered into the camera. This value is stored for each thermal image.Detector size 160 x 120 pixels (19,200 pixels)Providing optimum image quality and resolution, clearly and precisely on the Large Display.SuperResolution technology (to 320 x 240 pixels)SuperResolution technology improves the image quality byone class, increasing the resolution of the images in the software and reports by four times, to 76,800 pixels.Thermal sensitivity < 0.05°C (50 mK)Thanks to an excellent temperature resolution of up to <50 mK,even small temperature differences are visible (Testo 875i series).Built-in digital camera with power LEDsParallel to the thermal image, a real image of the measurement subject is also captured and stored. (Testo 875i series).Automatic Hot/Cold Spot RecognitionCritical measurement points for the Hottest and Coldest Spot temperatures are automatically displayed using the Auto Hot /Cold Spot Recognition feature.The advantages of the testo 875 and testo 875iSpecial measurement mode for detecting areas with danger of mouldUsing the externally measured ambient temperature and air humidity, as well as the surface temperature, the humidity value of each measurement point is calculated and shown in the display as a real humidity image,relating to the calculated Dewpoint. (Testo 875i series).Lens protection glassIntuitive operationtesto 875-1Technical data testo 875 and testo 875i–Infrared image outputDetector typeThermal sensitivity (NETD)Field of vision/min. focusing distanceImage refresh rateFocusSpectral rangeImage output visualImage size / min. focusing distanceImage presentationImage displayDisplay optionsVideo outputColour palettesMeasurementTemperature rangeHigh temperature measurement - optionalAccuracyEmissivity / reflected temperatureMeasuring functionsDisplay of surface moisture (via manual input)Humidity measurement with wireless humidity probe**(automatic measurement value transfer in real time)Analysis functionSolar modeImager equipmentPower LEDsDigital cameraStandard lensExchangeable lenses - optionalLaser*** (laser classification 635 nm, Class 2 )Voice recordingVideo streaming (via USB)Image storageFile formatStorage devicePower supplyBattery typeOperating timeCharging optionsMains operationAmbient conditionsOperating temperature rangeStorage temperature rangeAir humidityHousing protection class (IEC 60529)Vibration (IEC 60068-2-6)Physical specificationsWeightDimensions (L x W x H) in mmTripod mountingHousingPC softwareSystem requirementsStandards, tests, warrantyEU DirectiveWarrantyFPA 160 x 120 pixels, a.Si8 to 14 µmgrey, sepia, Testo, iron HT)manual32° x 23°640 x 480 pixels / 0.4 mwired headsetUp to 2 measure-ment points,Hot/Cold SpotRecognition( )Geometric resolution (IFOV).bmt; export options in .bmp, .jpg, .png, .csv, .xlsSD card 2 GB (approx. 2.000 images)Fast-charging, Li-ion battery can be changed on-site4 hoursIn instrument/in charging station (optional)Yes2GABS(Service Pack 1), interface USB 2.0SuperResolution (pixel / IFOV) - optional( )9° x 7°–testo 875-1i testo 875-2iUp to 2 measurementpoints, hot/cold Spotrecognition, isotherm,area measurement(Min-/Max-On-Area)testo 875 / testo 875i160 x 120 pixelsOverview of variantsFeatures* Within the EU and for countries without export restrictions, otherwise 9 Hz**excepting USA, China and JapanLens protection glassAdditional batteryFast battery chargertesto875-2iHumidity measurement with wirelesshumidity probe*** (automatic measure-ment valuetransfer in real time)SuperResolutionDetector< 50 mKThermal sensitivity (NETD)33 Hz*Image refresh rate-20 to +350 °CTemperature rangeHigh temperature measurement up to550 °CVoice recording using the headsetIntegrated power LEDsLens 32° x 23°Display of surface moisture(via manualinput)Laser**Integrated digital cameraAuto Hot/Cold Spot RecognitionSolar modeExchangeable telephoto lens 9° x 7°Isotherm display in instrumentMin/Max on Area calculationincluded in delivery optional( )( )( )( )( )( )( )( )( )( )( )***Wireless humidity probes only in the EU, Norway, Switzerland, Croatia, USA,Canada, Colombia, Turkey, Brazil, Chile, Mexico, New Zealand, Indonesia09818521/msp/Q/7.212Subjecttochangewithoutnotice.Ordering dataThermal imager testo 875-2i setin a robust case incl. pro software, Soft Case, carryingstrap, SD card, USB cable, lens cleaning cloth, mains unit,Li ion rechargeable battery and tripod adapter.In addition to the equipmentof the testo 875-2i, the testo875-2i set also includes:· Telephoto lens 9° x 7°· Lens protection glass· Additional battery· Fast battery chargerThermal imager testo 875-1in a robust case incl. pro software, Soft Case, carryingstrap, SD card, USB cable, lens cleaning cloth, mains unit,Li ion rechargeable battery and tripod adapter.Thermal imager testo 875-2iin a robust case incl. pro software, Soft Case, carryingstrap, SD card, USB cable, lens cleaning cloth, mains unit,Li ion rechargeable battery and tripod adapter.Thermal imagers testo 875 and 875i0563 0875 V30560 87510563 0875 V2Order no.We measure it.testo875-1testo875-1i< 80 mK-20 to+280 °C9 Hz( )( )( )( )( )( )( )( )––––––––testo875-2i set––––––––Thermal imager testo 875-1iin a robust case incl. pro software, Soft Case, carryingstrap, SD card, USB cable, lens cleaning cloth, mains unit,Li ion rechargeable battery and tripod adapter.0563 0875 V1––ISO calibration certificatesCalibration points at 0 °C, +25 °C, +50 °CCalibration points at 0 °C, +100 °C, +200 °CFreely selectable calibration points in therange -18 °C to +250 °C0520 04900520 04890520 0495Emissivity adhesive tape. Adhesive tape, e.g. for bare sur-faces (roll, L.: 10 m, W.: 25 mm), e=0.95,temperature-resistant to +250 °C0554 0051Fast battery charger. Desktop chargingstation for two rechargeable batteries forthe optimization of the charging time.0554 8801Additional battery. Lithium ion rechargeablebattery for extending the operating timeHigh temperature measurementup to 550 °C (testo 875-2i only)Humidity measurement with wirelesshumidity probe*** (only testo 875-2i)SuperResolution. Four times more mea-surement values for even more detailedanalysis of the thermal images.0554 88022)2) 3)0554 7806Lens protection glass. Special Germaniumprotective glass for optimum protection ofthe lens from dust and scratching0554 8805Order no.(Retrofit)E1D1G1B1S1C1Code1) (Firstequipmenttesto 875i)2) Please contact our customer service3) Plus installation1) When ordering as initial equipment, you receive the accessories directly in the case.Example: testo 875-1i incl. lens protection glass and spare battery:Order no. 0563 0875 V1 C1 D1AccessoriesTelephoto lens 9° x 7°(testo 875-2i only)2)A1Testo LimitedNewman Lane, Alton,Hampshire, GU34 2QJ, UKTelephone 01420 544433Fax 01420 544434******************.uk875-1I875-2I875-1。

伊玛产品类别

伊玛产品类别
四线
18~36 VDC
PNP NO/NC,NPN NO/NC
4~20 mA,0~10 V

PA1108
智慧型
7 LED
内螺纹
G 1/4
400 bar
四线
18~36 VDC
PNP NO/NC,NPN NO/NC
4~20 mA,0~10 V

PA1109
智慧型
7 LED
内螺纹
G 1/4
2 bar
四线
18~36 VDC
200
60
M12
接插件
N
Y
N
IP67

IA0031
齐平
brass
10~36VDC
1
两线
NO
DC PNP/NPN
200
60
M12
接插件
N
Y
N
IP67

IA0032
齐平
brass
10~36VDC
1
两线
NC
DC PNP/NPN
200
60
M12
接插件
N
Y
N
IP67

IA0033
非齐平
brass
10~36VDC

TA1099
智慧型
7 LED
内螺纹
M18 X 1.5
-40~150°C
四线
20~30 VDC
PNP NO/NC,NPN NO/NC
4~20 mA,0~10 V

产品类别
压力变送器(模拟量输出)
压力变送器(开关量输出)
订货号
功能
显示
牙口形式

IRM-8410中文资料

IRM-8410中文资料

OFFICE: NO 25,Lane 76,Chung Yang Rd, Sec.3 Tucheng, Taipei 236, Taiwan, R.O.C. TEL : 886-2-2267-2000,2266-9936 ( 22 Lines )FAX : 886-2-2267-6189■NOTES:1. This drawing measure is a standard value. All dimensions are in millimeter.2. In case of designation is tolerance ±0.3mm.3. Lead spacing is measured where the lead emerge from the package.4. Above specification may be changed without notice. EVERLIGHT will reserve authorityon material change for above specification.5. These specification sheets include materials protected under copyright of EVERLIGHTcorporation. Please don't reproduce or cause anyone to reproduce them withoutEVERLIGHT consent.6. When using this produce, please observe the absolute maximum ratings and theinstructions for use outlined in these specification sheets. EVERLIGHT assumes no responsibility for any damage resulting from use of the product which does not comply with the absolute maximum ratings and the instructions included in these specification sheets.■Description:1. The module is a small type infrared remote control system receiver which has beendeveloped and designed by utilizing the latest hybrid technology.2. This single unit type module incorporates a photo diode and a receiving preamplifier IC.3. The demodulated output signal can directly be decoded by a microprocessor.■ Feature:1.High protection ability to EMI and metal case can be customized.2.Mold type and metal case type to meet the design of front panel.3.Elliptic lens to improve the characteristic against4.Line-up for various center carrier frequencies.5.Low voltage and low power consumption.6.High immunity against ambient light.7.Photodiode with integrated circuit.8.TTL and CMOS compatibility.9.Long reception distance.10.High sensitivity.■Application:1. Optical switch2. Light detecting portion of remote control•AV instruments such as Audio, TV, VCR, CD, MD, etc.•Home appliances such as Air-conditioner, Fan , etc.•The other equipments with wireless remote control.•CATV set top boxes•Multi-media Equipment■ Absolute maximum ratings:(Ta=25℃) Parameter Symbol Ratings Unit Notice Supply Voltage Vcc 4.3~5.7VOperating Temperature Topr-10〜+60℃Storage Temperature Tstg-20〜+70℃Soldering Temperature Tsol260℃4mm from mold bodyless than 5 seconds ■ Electro Optical Characteristics:(Ta=25℃) Parameter Symbol MIN TYP MAX Unit ConditionSupply Voltage Vcc 4.75 5.3V DC voltageSupply Current Icc--3mA No signal inputB.P.F CenterFrequencyfo-37.9-KHzPeak Wavelengthλp-940-nmL06--TransmissionDistance L453-m At the ray axis*1Half Angleθ-45-deg High Level PulseWidthT H400-800µsLow Level PulseWidth T L400-800µsAt the ray axis*2High Level OutputVoltageV H 4.5--VLow Level OutputVoltageV L0.5V*1:The ray receiving surface at a vertex and relation to the ray axis in the range of φ= 0° and φ=45°.*2:A range from 30cm to the arrival distance. Average value of 50 pulses.MODEL NO:IRM-8410/N ECN: Page: 5/9■ TEST METHOD:The specified electro-optical characteristics is satisfied under the following Conditions at the controllable distance.c Measurement placeA place that is nothing of extreme light reflected in the room.d External lightProject the light of ordinary white fluorescent lamps which are not highFrequency lamps and must be less then 10 Lux at the module surface.(Ee≦10Lux)e Standard transmitterA transmitter whose output is so adjusted as to Vo=400mVp-p and the outputWave form shown in Fig.-1.According to the measurement method shown in Fig.-2 the standard transmitter is specified. However, the infrared photodiode to be used for the transmitter should be λp=940nm, ∆λ=50nm. Also, photo diode is used of PD438B (V R=5V).(Standard light / Light source temperature 2856°K).f Measuring systemAccording to the measuring system shown in Fig.-3MODEL NO:IRM-8410/N ECN: Page: 6/9EVERLIGHT ELECTRONICS CO., LTD.Device Number:DMO-841-001 REV: 1.1 MODEL NO:IRM-8410/N ECN: Page: 7/9MODEL NO:IRM-8410/N ECN: Page: 8/9■ Reliability test item and condition :The reliability of products shall be satisfied with items listed below. Confidence level: 90% LTPD: 10%Samples(n)Test Items Test ConditionsFailure JudgementCriteriaDefective(c)Operation life Vcc=5V,Ta:25℃ 1000hrs n=22,c=0Temperature cycle 1 cycle -20℃ +25℃ +70℃ (30min) 5min (30min) 50 cycle test n=22,c=0Thermal shock-10℃ to +70℃ (5min) (10sec) (5min) 50 cycle testL 0≦ L ×0.8L 45≦ L ×0.8 n=22,c=0High temperaturestorageTemp: +70℃ 1000hrsn=22,c=0Low temperaturestorageTemp: -20℃ 1000hrsn=22,c=0High temperatureHigh humidityTa: 85℃ RH:85% 1000hrsn=22,c=0Solder heat Temp: 260±5℃ 5sec4mm Form the bottom of thepackage.L: Lowerspecification limit n=22,c=0Solderability Temp: 230±5℃ 5sec4mm Form the bottom of thepackage.More than 90% ofLead to be covered by solderingn=22,c=0。

CE875 即时 发卡系统 用户参考指南说明书

CE875 即时 发卡系统 用户参考指南说明书

527763-001ZHT_E
CE875即时发卡系统用户参考指南
3
Chinese
Chinese
Chinese
多卡槽卡箱打印机 多卡槽卡箱打印机
C B
H I DJ
E
A
A = 出卡槽 B = 卡槽锁扣 C = 1-6号进卡槽 D = 多卡槽锁 E = 锁扣解锁按钮(B1)
G
F
F = 取卡盒按钮 G = 额外进卡槽 H = 卡片压块 I = 卡盒门 J = 卡盒门释放按钮
Chinese
Chinese
b
胶带
1
2
b
胶带
1
2
32
CE875即时发卡系统用户参考指南
527763-001ZHT_E
527763-001ZHT_E
CE875即时发卡系统用户参考指南
33
修复断裂的凹字色带 修复断裂的凹字色带
a
修复断裂的烫金色带
a
修复断裂的烫金色带
Chinese
Chinese
b
胶带
b
胶带
34
CE875即时发卡系统用户参考指南
527763-001ZHT_E
527763-001ZHT_E
CE875即时发卡系统用户参考指南
35
Chinese
Chinese
检查电源的连接 检查电源的连接
打印机电源线连接
凸字机电源线连接
检查数据线的连接
打印机和凸字机连接
检查数据线的连接
网络线连接
36
CE875即时发卡系统用户参考指南
使用额外的卡槽
4
5
6
使用额外的卡槽
Chinese

MMBT5401高电压PNP Silicon M5A艾克拉特透视器数据表说明书

MMBT5401高电压PNP Silicon M5A艾克拉特透视器数据表说明书

UNITS mW
mW/oC oC/W mW
mW/oC oC/W
oC
ELECTRICAL CHARACTERISTICS (T =25OC unless otherwise noted) A
CHARACTERISTIC
OFF CHARACTERISTICS
Collector-Emitter Breakdown Voltage (I C=-1.0mAdc,I B=0) Collector-Base Breakdown Voltage (I C=-100μAdc,I E=0) Emitter-Base Breakdown Voltage (I E=-10μAdc,I C=0) Collector Cutoff Current (VCB=-120Vdc, I E=0) (VCB=-120Vdc, I E=0, TA=100oC)
PNP
June 5,2018-REV.03
Fig.35 PAGE . 1
MMBT5401
THERMAL CHARACTERISTICS
CHARACTERISTIC
Total Device Dissipation FR-4 Board (Note 1) TA=25oC Derate Above 25oC Thermal Resistance, Junction-to-Ambient Total Device Dissipation Alumina Substrate (Note 2) TA=25oC Derate Above 25oC Thermal Resistance Junction-to-Ambient
MMBT5401
HIGH VOLTAGE TRANSISTOR PNP Silicon

TWH8751简介

TWH8751简介

第二节开关集成电路一、开关集成电路TWH8751简介TWH8751是一种使用非常广泛的开关集成电路,如图6-3所示,它有五个引脚,其中第5脚用于接正电源,它所使用的电源电压在12~24V,3脚用于接地,并且在3脚和4脚之间是一个开关,这个开关是由1脚来进行控制的:当1脚为高电平时,开关就闭合,否则开关就断开,这个开关闭合时,电流只能单方向从4脚向3脚流动。

但在有的时候,我们希望这个开关不受任何电压的控制,这时就可以利用2脚,一般情况下2脚就接一个低电压(≤1.2V),但如果2脚接上一个高电压时,1脚就图6-3 TWH8751外形不能再对开关起控制作用了,并且开关会保持在断开的状态。

我们用表6-1来说明1脚和2脚对开关的控制。

表6-1这个表我们以后还会见到很多,用“0”来表示低电平或开关断开,用“1”表示高电平或开关闭合。

在这个表中我们可以很清楚地看到,TWH8751的1脚和2脚都可以作为对开关的控制端,而且这两个控制端是只需要电压的,对电流的要求非常小,有0.1—0.2mA就足够了,但在4脚所接的开关上,却可以流过大到2A的电流,同时还可以承受80~100V的高电压。

为了让这个开关能可靠地工作,TWH8751内还设置了完善的保护电路:如果流过开关的电流超过3A时,保护电路会自动地使这个电流减少到IA左右,避免集成块被过大的电流烧毁。

使用TWH8751来作为开关比使用三极管来作为开关要优越得多,首先是能够流过的电流非常的大,这可以在很多的场合下适用;其次是TWH8751的控制电流特别小,大大降低了前面控制电路的复杂程度;第三是TWH8751没有放大状态,只有开的状态和关的状态,可以避免在电路中想很多办法(如用正反馈)来减少处于放大状态的时间,节省了我们的脑力。

二、TWH8751的应用电路实例下面我们用TWH8751和前面我们介绍过的音乐集成电路KD-9300来制作一个音乐彩灯,这种灯的亮度会随着音乐的声音强弱变化而变化。

DBJ/T 01-26-2003建筑安装分项工程施工工艺规程(第四分册)

DBJ/T 01-26-2003建筑安装分项工程施工工艺规程(第四分册)

北京市地方性标准 DB编号:DBJ/T01-26-2003备案号:J10313—2003建筑安装分项工程施工工艺规程Construction Workmanship Codefor Builder’s Work and Building Service Work Items(第四分册)第7篇地面与楼面工程第8篇门窗工程第9篇屋面工程2003—12-15 发布 2004—03-01 实施北京市建设委员会发布目次第7篇地面与楼面工程1 灰土垫层 (17)1.1 材料要求 (17)1.2 主要机具 (17)1.3 作业条件 (17)1.4 操作工艺 (18)1.5 质量标准 (19)1.6 成品保护 (20)1.7 应注意的问题 (20)2 砂垫层和砂石垫层 (21)2.1 材料要求 (21)2.2 主要机具 (21)2.3 作业条件 (21)2.4 操作工艺 (22)2.5 质量标准 (23)2.6 成品保护 (24)2.7 应注意的问题 (24)3 水泥混凝土垫层 (25)3.1 材料要求 (25)3.2 主要机具 (25)3.3 作业条件 (25)3.4 操作工艺 (26)3.5 质量标准 (28)3.6 成品保护 (28)3.7 应注意的问题 (29)4 找平层 (30)4.1 材料要求 (30)4.2 主要机具 (30)4.3 作业条件 (30)4.4 操作工艺 (30)4.5 质量标准 (31)4.6 成品保护 (32)4.7 应注意的问题 (32)5 隔离层 (33)5.1 材料要求 (33)5.2 主要机具 (33)5.3 作业条件 (33)5.4 施工工艺 (34)5.5 质量标准 (35)5.6 成品保护 (36)5.7 应注意的问题 (36)6 低温热水楼面辐射采暖地板 (37)6.1 材料要求 (37)6.2 主要机具 (39)6.4 施工工艺 (40)6.5 质量标准 (42)6.6 成品保护 (44)6.7 应注意的问题 (44)7 水泥混凝土面层 (45)7.1 材料要求 (45)7.2 主要机具 (45)7.3 作业条件 (45)7.4 操作工艺 (46)7.5 质量标准 (48)7.6 成品保护 (49)7.7 应注意的问题 (49)8 水泥砂浆地面 (50)8.1 材料要求 (50)8.2 主要机具 (50)8.3 作业条件 (50)8.4 操作工艺 (51)8.5 质量标准 (53)8.6 成品保护 (54)8.7 应注意的问题 (54)9现制水磨石地面 (55)9.1 材料要求 (55)9.3 作业条件 (55)9.4 操作工艺 (56)9.5 质量标准 (61)9.6 成品保护 (62)9.7 应注意的问题 (63)10 水泥钢(铁)屑面层 (64)10.1 材料要求 (64)10.2 主要机具 (64)10.3 作业条件 (64)10.4 操作工艺 (65)10.5 质量标准 (66)10.6 成品保护 (67)10.7 应注意的问题 (67)11 防油渗面层 (68)11.1 材料要求 (68)11.2 主要机具 (68)11.3 作业条件 (68)11.4操作工艺 (69)11.5 质量标准 (72)11.6 成品保护 (73)11.7 应注意的问题 (73)12 不发火(防爆的)面层 (74)12.2 主要机具 (74)12.3 作业条件 (74)12.4 操作工艺 (74)12.5 质量标准 (75)12.6 成品保护 (75)12.7 应注意的问题 (75)13 环氧自流平面层涂饰 (76)13.1 材料要求 (76)13.2 主要机具 (76)13.3 作业条件 (76)13.4 操作工艺 (76)13:5 质量标准 (77)13.6 成品保护 (77)13.7 应注意的问题 (78)14 砖面层 (79)14.1 材料要求 (79)14.2 主要机具 (79)14.3 作业条件 (80)14.4 操作工艺 (80)14.5 质量标准 (84)14.6 成品保护 (84)14.7 应注意的问题 (85)15 大理石面层、花岗岩面层和人造石 (87)15.1 材料要求 (87)15.2 主要机具 (87)15.3 作业条件 (87)15.4 操作工艺 (88)15.5 质量标准 (92)15.6 成品保护 (92)15.7 应注意的问题 (93)16 料石面层 (95)16.1 材料要求 (95)16.2 主要机具 (95)16.3 作业条件 (95)16.4 施工工艺 (96)16.5 质量标准 (97)16.6 成品保护 (98)16.7 应注意的问题 (98)17 塑料板面层 (99)17.1 材料要求 (99)17.2 主要机具 (99)17.3 作业条件 (99)17.4 操作工艺 (100)17.5 质量标准 (102)17.6 成品保护 (102)17.7 应注意的问题 (103)18 地毯面层...............................................................lO4 18.1 材料要求 (104)18.2 主要机具 (105)18.3 作业条件 (105)18.4 操作工艺 (106)18.5 质量标准 (108)18.6 成品保护 (108)18.7 应注意的问题 (109)19 活动地板面层 (110)19.1 材料要求 (110)19.2 主要机具 (110)19.3 作业条件 (110)19.4 操作工艺 (111)19.5 质量标准 (113)19.6 成品保护 (114)19。

TWH8751简介

TWH8751简介

第二节开关集成电路一、开关集成电路TWH8751简介TWH8751是一种使用非常广泛的开关集成电路,如图6-3所示,它有五个引脚,其中第5脚用于接正电源,它所使用的电源电压在12~24V,3脚用于接地,并且在3脚和4脚之间是一个开关,这个开关是由1脚来进行控制的:当1脚为高电平时,开关就闭合,否则开关就断开,这个开关闭合时,电流只能单方向从4脚向3脚流动。

但在有的时候,我们希望这个开关不受任何电压的控制,这时就可以利用2脚,一般情况下2脚就接一个低电压(≤1.2V),但如果2脚接上一个高电压时,1脚就图6-3 TWH8751外形不能再对开关起控制作用了,并且开关会保持在断开的状态。

我们用表6-1来说明1脚和2脚对开关的控制。

表6-1这个表我们以后还会见到很多,用“0”来表示低电平或开关断开,用“1”表示高电平或开关闭合。

在这个表中我们可以很清楚地看到,TWH8751的1脚和2脚都可以作为对开关的控制端,而且这两个控制端是只需要电压的,对电流的要求非常小,有0.1—0.2mA就足够了,但在4脚所接的开关上,却可以流过大到2A的电流,同时还可以承受80~100V的高电压。

为了让这个开关能可靠地工作,TWH8751内还设置了完善的保护电路:如果流过开关的电流超过3A时,保护电路会自动地使这个电流减少到IA左右,避免集成块被过大的电流烧毁。

使用TWH8751来作为开关比使用三极管来作为开关要优越得多,首先是能够流过的电流非常的大,这可以在很多的场合下适用;其次是TWH8751的控制电流特别小,大大降低了前面控制电路的复杂程度;第三是TWH8751没有放大状态,只有开的状态和关的状态,可以避免在电路中想很多办法(如用正反馈)来减少处于放大状态的时间,节省了我们的脑力。

二、TWH8751的应用电路实例下面我们用TWH8751和前面我们介绍过的音乐集成电路KD-9300来制作一个音乐彩灯,这种灯的亮度会随着音乐的声音强弱变化而变化。

原子舌部进口太阳能对比选择器说明书

原子舌部进口太阳能对比选择器说明书

The Fluke 576 Photographic Non-contact ThermometerInfrared temperature measurement withdigital photos Technical DataIntroducing the world’sfirst precision infrared (IR) thermometer with integral digital photography. For the most complete temperature documentation solution, predictive maintenance professionals use the Fluke 576 precision IR thermometer.insetapplication phototo comeMeasurePhotographDocumentAny infrared thermometer can measure temperature, but only the Fluke 576 thermometer measures temperature while digitally photographing the measured area and its surroundings.The proof is in the picture! Temperature measurement locations are instantly captured in a digital photo with a time and date stamp in the image. The laser sighting pinpoints the exact measurement location, without the need for a view finder.Make sure the inspection was done properly. Download images and data to the PC software and double-check all work.Ensure consistency of repeated measurements by using prior photos as a reference—position the laser sighting as shown in the photo to assure the measurement area is the same.Create customized company reports with the software, data and photos. Just insert information from Fluke 576 data files into reports for fast, professional results.insetapplication photo tocomeAdvanced display •Icons for camera active, flash active, and flash charging, and indication of photos remaining•Confirmation of a successful photo taken•30 preset common material emissivities •Adjustable emissivity values (0.01 increments)•100 location logging capability •Customized log location names and alarmsClose Focus OptionThe Close Focus (CF) option lets you accurately measure very small areas at the focus point – where the IR beam narrows. Paired with an advanced coaxial laser sighting system, extremely small objects 6 mm (0.24 in) at 300 mm (11.4 in) can be easily measured. Ideal for electrical maintenance and refrigeration troubleshooting.©2005 Fluke Corporation. All rights reserved. Printed in U.S.A. 4/2005 2437668 D-US-N Rev AFluke. Keeping your world up and running.SpecificationsOrdering Information Options• Close focus• NIST calibration certificate Accessories • Analog cableIncluded with Fluke 576 unit:• User’s guide (on CD)• Hardshell carrying case • PC software• USB computer cable • Thermocouple K probe• Padded pouch with belt clipAnalog cable accessory。

Philips HD8751用户手册说明书

Philips HD8751用户手册说明书

USER MANUALPLEASE READ THIS USER MANUAL CAREFULLY BEFORE USING THE MACHINE.Register your product and get support at /welcome l i sType HD8751E N0202IMPORTANT SAFEGUARDSWhen using electrical appliances, basic safety precautions should always be followed, including the following:1. Read all instructions.2. Do not touch hot surfaces. Use handles or knobs.3. To protect against fire, electric shock and injury to persons do not immerse cord, plugs, or appliance in water or other liquid.4. Close supervision is necessary when the appliance is used by or near children.5. Unplug from outlet when not in use and before cleaning. Allow to cool before putting on or taking off parts, and before cleaning the appliance.6. Do not operate any appliance with a damaged cord or plug or after the appliance malfunctions, or has been damaged in any manner. Return appliance to the nearest authorized service facility for examination, repair or adjustment.7. The use of accessory attachments not recommended by the appliance manufacturer may result in fire, electric shock or injury to persons.8. Do not use outdoors.9. Do not let cord hang over edge of table or counter, or touch hot surfaces.10. Do not place on or near a hot gas or electric burner, or in a heated oven.11. A lways attach plug to appliance first, then plug cord into wall outlet. To disconnect, turn any control to “off”, then remove plug from wall outlet.12. D o not use appliance for other than intended use.13. S ave these instructions.SAVE THESE INSTRUCTIONSCAUTIONThis appliance is for household use only. Any servicing, other than cleaning and user maintenance, should be performed by an authorized service center. Do not immerse machine in water. To reduce the risk of fire or electric shock, do not disassemble the machine. There are no parts inside the machine serviceable by the user. Repair should be done by authorized service personnel only.1. Check voltage to be sure that the voltage indicated on the nameplate corresponds with your voltage.2.Never use warm or hot water to fill the water tank. Use cold water only.3.Keep your hands and the cord away from hot parts of the appliance during operation.4.Never clean with scrubbing powders or harsh cleaners. Simply use a soft cloth dampened with water.5. For optimal taste of your coffee, use purified or bottled water. Periodic descaling is still recommended every 2-3 months.6.Do not use caramelized or flavored coffee beans. INSTRUCTIONS FOR THE POWERSUPPL Y CORDA. A short power-supply cord (or detachable power-supply cord) is to be provided to reduce risks resulting from becoming entangled in or tripping over a longer cord.B. Longer detachable power-supply cords or extension cords are available and may used if care is exercised in their use.C. If a long detachable power-supply cord or extension cord is used,1. The marked electrical rating of the detachable power-supply cord orextension cord should be at least as great as the electrical rating of the appliance2. If the appliance is of the grounded type, the extension cord should be agrounding-type 3-wire cord, and3. The longer cord should be arranged so that it will not drape over thecounter top or table top where it can be pulled on by children or tripped over.4ENGLISHENGLISH58ENGLISHll the water tank with warm, hot, sparkling water or any otheree bean hopper lid and slowly pour the coff ee beans ee bean hopper.ee beans into the coff ee bean hopper as this willee beans must be put into the coff ee bean hopper. Ground ee, caramelized coff ee or any other object mayee bean hopper.Press the “” button to start dispensing hot water.ll the water tank again up to the MAX level. Now the ma-ee.starting up the machine (with cold boiler), when the machine is preparing to go into stand-by mode or after you have pressed the “” button (after a3 Select the “RESET” option. Press the “” button to confi rm.4 To exit, press the “” button.The machine is now programmed to manage a new fi lter.Note:If the fi lter is already installed and you want to remove - but not replace -it, select the “OFF” option instead.If there is no “INTENZA+” water fi lter installed, insert the small white fi lterpreviously removed into the water tank.=pre-ground cofflter.ee grounds drawer.Press the “” button to select the pre-ground coff ee function, without adding ground coff ee.Press the “” button to start a coff ee brewing cycle.Press the “” button to turn off the machine, and let the solution take ect for approximately 15 minutes. Make sure you discard the dispen-ee ground drawer and open the service door. Removeee residues drawer and then the brew group.lter from the water tank if it was instal- Press the “” button. Press the “” button until the followingdisplay is shown.Press the “” button to enter the descaling menu.If you press the “” button by mistake, press the “” button to quit.er. Then fi ll the water tank with fresh water up to the MAX level.9 Press the “” button to start the descaling cycle.10 The machine will start dispensing the descaling solution at intervals. The bar on the display shows the cycle progress. Note: The descaling cycle may be paused by pressing the “” button .To resume the cycle, press the “” button again. This allows you to empty the contai-ner or to stay away from the machine for a brief period of time.11 When this icon is displayed, the water tank is empty. 12 Remove the water tank, rinse it and fi ll it up to the MAX level with fresh water. Place it back into the machine.13 Empty the drip tray and place it back.14 Empty the container and place it back under the steam/hot water wand and dispensing spout.15 When inserting the water tank into the machine, this icon is displayed. Press the “” button to start the rinsing cycle. 16 When this icon is displayed, the water tank is empty. Repeat steps 12 – 15. Then continue to step 17.ENGLISH39ll it completely dispensed, this icon on the side is displayed. Press the“”lter into the water tank if it waslled up to MAX level, the machine might require40ENGLISHENGLISH4142ENGLISHENGLISH43 The red icon is alwaysdisplayed on the machine.always be emptied with the machineon. Wait until the icon is displa-tting the drawer.44ENGLISHENGLISH4546ENGLISHENGLISH47。

IS 875 (Part 1) 1987 R 1997

IS 875 (Part 1) 1987 R 1997

29 29 29 29 29 29 29 30 31 31 32 33 33 34 34 36 37 37
2
IS : 875 (Part 1) - 1987
Indian Standard C O D E O F P R A C T IC E F O R D E S IG N L O A D S (O T H E R T H A N E A R T H Q U A K E ) F O R B U IL D IN G S A N D S TR U C T U R E S
PART 1 DEAD LOADS — UNIT WEIGHTS OF BUILDING MATERIALS AND STORED MATERIALS
( Second Revision )
(Incorporating Amendment No. 1)
UDC 624.042 : 006.76
© BIS 2002
BUREAU
OF INDIAN
STANDARDS
MANAK BHAVAN , 9 BAHADUR SHAH ZAoup 12
IS : 875 (Part 1) - 1987
CONTENTS PAGE 0. FOREWORD 1. SCOPE 2. BUILDING MATERIALS TABLE 1 UNIT WEIGHT OF BUILDING MATERIALS 1. Acoustical material 2. Aggregate, coarse 3. Aggregate, fine 4. Aggregate, organic 5. Asbestos 6. Asbestos cement building pipes 7. Asbestos cement gutters 8. Asbestos cement pressure pipes 9. Asbestos cement sheeting 10. Bitumen 11. Blocks 12. Boards 13. Bricks 14. Brick chips and broken bricks 15. Brick dust ( SURKHI ) 16. Cast iron, manhole covers 17. Cast iron, manhole frames 18. Cast iron pipes 19. Cement 20. Cement concrete, plain 21. Cement concrete, prestressed 22. Cement concrete, reinforced 23. Cement concrete pipes 24. Cement mortar 25. Cement plaster 26. Cork 27. Expanded metal 28. Felt, bituminous for waterproofing and damp-proofing 29. Foam slag, foundry pumice 30. Glass 31. Gutters, asbestos cement 32. Gypsum 33. Iron 34. Lime 35. Linoleum 36. Masonry brick 37. Masonry, stone 38. Mastic asphalt 39. Metal sheeting, protected 40. Mortar 41. Pipes 42. Plaster 43. Sheeting 44. Slagwool 1 4 4 4 4 4 4 5 5 5 5 5 5 6 6 6 7 7 7 7 7 8 8 8 8 8 8 8 9 9 9 9 9 9 9 10 10 10 10 10 10 11 16 16 17 3 4 4

eCartex单 details seal 机械ментArea seal Я機械Address s

eCartex单 details seal 机械ментArea seal Я機械Address s

Features AdvantagesOperating range Shaft diameter:d1 = 25 ... 100 mm (1.000" ... 4.000")Other sizes on request Temperature:t= -40 °C ... 220 °C (-40 °F ... 428 °F)(Check O-Ring resistance)Sliding face material combination BQ1Pressure: p1 = 25 bar (363 PSI)Sliding velocity: vg = 16 m/s (52 ft/s)Sliding face material combination Q1Q1 or U2Q1:Pressure: p1 = 12 bar (174 PSI)Sliding velocity: vg = 10 m/s (33 ft/s)Axial movement: ±1.0 mm, d 1 ≥75 mm ±1.5 mmMaterialsSeal face: Silicon carbide DiamondFace (Q15) Seat: Silicon carbide DiamondFace (Q15) Secondary seals: FKM (V), EPDM (E), FFKM (K), Perfluorcarbon rubber/PTFE (U1) Springs: Hastelloy® C-4 (M)Metal parts: CrNiMo steel (G), CrNiMo cast steel (G)Recommended applications Single seal •Cartridge •Balanced•Independent of direction of rotation •Single seals without connections (-SNO), with flush (-SN) and with quench combined with lip seal (-QN) or throttle ring (-TN)•Additional variants available for ANSI pumps (e.g. -ABPN) and eccentric screw pumps (-Vario)•The series has sliding surfaces that are equipped with EagleBurgmannDiamondFace technology as standard •Up to 80 % less energy consumption and minimized heat generation of seal due to friction-reducing DiamondFace layer •Up to 100 % extended operating period, prolongation of MTBF and MTBR intervals •Significantly improved dry-run capability for inadequately lubricated sealing surfaces, thus vastly improved process safety•Universally applicable, even with high solids content in the medium•Process industry•Petrochemical industry •Chemical industry•Pharmaceutical industry •Power plant technology •Pulp and paper industry•Water and waste water technology •Mining industry•Food and beverage industry •Sugar industry•Universally applicable •Centrifugal pumps•Eccentric screw pumps •Process pumps•1Seal face2, 5, 7O-Ring3Spring4Seat6Shaft sleeve8Drive collar9Set screw10Snap ring11Cover12Assembly fixture13Screw14Gasket15Screw plug16Lip seal (-QN), throttle ring (-TN)Seal coverCast versionSeal coverMachined version Installation, details, optionseCartex-SNOSingle seal without connections, for dead-endoperation.eCartex-TNSingle seal for operation with unpressurizedquench. Same as eCartex-SN but with throttle ring(item 16). The cover has auxiliary connections forflushing and quench.Throttle ring: PTFE carbon-graphite reinforced(T12).eCartex-QNSingle seal for operation with unpressurizedquench. Same as "-SN' version but with outboard lipseal (item 16). The cover has auxiliary connectionsfor flushing and quench.Lip seal: NBR (P), PTFE carbon reinforced (T3). Product variantseCartex-VarioCartridge seals with modified cover for eccentricscrew pumps.For e.g. Seepex BN,Netzsch NM...S, NM...B, NE (P),Allweiler AE, AEB, AED,Robbins & Myers / Moyno 2000 CC,and Mono E-Range.Please inquire.Dimensionsd1d2d3min.d3max.l1l2l3l4l12l13l14l15l16l17a1d a s1.000 1.693 1.7502.000 2.640 1.6690.969 1.000 1.378 1.2600.6893.130 2.102 1.028 2.4404.1340.520 1.125 1.811 1.875 2.050 2.640 1.6690.969 1.000 1.378 1.2600.689 3.130 2.102 1.028 2.440 4.1340.520 1.250 1.960 2.000 2.250 2.640 1.6690.969 1.000 1.378 1.2600.689 3.130 2.102 1.028 2.640 4.3300.520 1.375 2.086 2.125 2.420 2.640 1.6690.969 1.000 1.378 1.2600.689 3.130 2.102 1.028 2.750 4.4490.520 1.500 2.200 2.250 2.625 2.640 1.6690.969 1.000 1.378 1.2600.689 3.130 2.102 1.028 2.950 4.8420.520 1.625 2.340 2.375 2.700 2.640 1.6690.969 1.000 1.378 1.2600.689 3.130 2.102 1.028 3.030 4.8420.599 1.750 2.460 2.500 2.812 2.640 1.6690.969 1.000 1.378 1.2600.689 3.130 2.102 1.028 3.1905.4330.5991.8752.582 2.625 2.940 2.640 1.6690.969 1.000 1.378 1.2600.6893.130 2.102 1.028 3.190 5.4330.5992.000 2.677 2.7503.190 2.640 1.6690.969 1.000 1.378 1.2600.689 3.130 2.102 1.028 3.430 5.8270.599 2.125 2.834 2.875 3.437 2.640 1.6690.969 1.000 1.378 1.2600.689 3.130 2.102 1.028 3.820 5.8270.709 2.250 2.960 3.000 3.560 2.640 1.6690.969 1.000 1.378 1.2600.689 3.130 2.102 1.028 3.940 6.1810.709 2.375 3.070 3.125 3.590 2.640 1.6690.969 1.000 1.378 1.2600.689 3.130 2.102 1.0284.020 6.1810.709 2.500 3.212 3.250 3.800 2.640 1.6690.969 1.000 1.378 1.2600.689 3.130 2.102 1.028 4.170 6.4170.709 2.625 3.338 3.375 3.937 2.640 1.6690.969 1.000 1.378 1.2600.689 3.130 2.102 1.028 4.290 6.4170.709 2.750 3.660 3.750 4.250 2.640 1.6690.969 1.000 1.378 1.2600.689 3.130 2.102 1.028 4.6507.0080.7092.8753.9374.000 4.646 3.307 2.260 1.047 1.000 1.815 1.4920.866–––5.0797.4800.7093.000 3.9374.000 4.646 3.307 2.260 1.047 1.102 1.815 1.4920.866 3.858 2.516 1.3435.0797.4800.709 3.125 4.190 4.125 4.764 3.307 2.260 1.047 1.102 1.815 1.4920.866 3.858 2.516 1.343 5.3157.6770.709 3.250 4.189 4.250 4.882 3.307 2.260 1.047 1.102 1.815 1.4920.866––– 5.3157.6770.709 3.375 4.311 4.375 5.039 3.307 2.260 1.047 1.102 1.815 1.4920.866––– 5.4727.7950.866 3.500 4.437 4.500 5.157 3.307 2.260 1.047 1.102 1.815 1.4920.866––– 5.5917.7950.866 3.625 4.563 4.625 5.315 3.307 2.260 1.047 1.102 1.815 1.4920.866––– 5.7098.0710.8663.7504.689 4.7505.433 3.307 2.260 1.047 1.102 1.815 1.4920.866 3.858 2.516 1.343 5.8278.1890.8664.000 4.9375.000 5.669 3.307 2.260 1.047 1.102 1.815 1.4920.866–––6.0638.5830.866 Dimensions in inchDimensions1233123412131415161712543.044.051.56742.424.625.435.032.017.579.553.426.16210513.2 2846.047.052.06742.424.625.435.032.017.579.553.426.16210513.2 3048.049.056.06742.424.625.435.032.017.579.553.426.16510513.2 3249.851.057.06742.424.625.435.032.017.579.553.426.16711013.2 3349.851.057.06742.424.625.435.032.017.579.553.426.16711013.2 3553.054.061.56742.424.625.435.032.017.579.553.426.17011313.2 3856.057.066.06742.424.625.435.032.017.579.553.426.17512313.2 4058.059.068.06742.424.625.435.032.017.579.553.426.17512314.2 4260.561.569.56742.424.625.435.032.017.579.553.426.18013314.2 4360.561.570.56742.424.625.435.032.017.579.553.426.18013314.2 4562.564.073.06742.424.625.435.032.017.579.553.426.18113814.2 4865.667.075.06742.424.625.435.032.017.579.553.426.18413814.2 5068.069.078.06742.424.625.435.032.017.579.553.426.18714814.2 5372.073.087.06742.424.625.435.032.017.579.553.426.19714818.0 5573.074.083.06742.424.625.435.032.017.579.553.426.19014818.0 6078.079.091.06742.424.625.435.032.017.579.553.426.110215718.0 6584.885.798.56742.424.625.435.032.017.579.553.426.110916318.0 7093.095.0108.06742.424.625.435.032.017.579.553.426.111817818.0 75100.0101.6118.08457.426.628.046.137.922.098.063.934.112919018.0 80106.4108.0124.08457.426.628.046.137.922.098.063.934.113519518.0 85109.5111.1128.08457.426.628.046.137.922.098.063.934.113919822.0 90115.9117.5135.08457.426.628.046.137.922.098.063.934.114520522.0 95119.1120.7138.08457.426.628.046.137.922.098.063.934.114820822.0 100125.4127.0144.08457.426.628.046.137.922.098.063.934.115421822.0 Dimensions in Millimeter。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

元器件交易网EVERLIGHT ELECTRONICS CO.,LTD.Technical Data Sheet Infrared Remote-control Receiver ModuleIRM-8751-1Features‧High protection ability against EMI . ‧Oval lens to improve the receive angles. ‧Line-up for various center carrier frequencies. ‧Low voltage and low power consumption. ‧High immunity against ambient light. ‧Photodiode with integrated circuit. ‧TTL and CMOS compatibility. ‧Long reception distance. ‧High sensitivity.DescriptionsThe device is a miniature type infrared remote control system receiver which has been developed and designed by utilizing the most updated IC technology. The PIN diode and preamplifier are assembled on lead frame, the epoxy package is designed as an IR filter. The demodulated output signal can directly be decoded by a microprocessor.Applications1. Optical switch 2. Light detecting portion of remote control ․AV instruments such as Audio, TV, VCR, CD, MD, etc. ․Home appliances such as Air-conditioner, Fan , etc. ․The other equipments with wireless remote control. ․CATV set top boxes ․Multi-media EquipmentDevice Selection GuidePART Chip Metal can Package MATERIAL Silicon Tinplate Epoxy COLOR -----Silver-white BlackEverlight Electronics Co., Ltd. Device No:DMO-870-003http:\\ Prepared date:07-23-2004Rev 1.2Page: 1 of 9Prepared by:CarryllHsu元器件交易网EVERLIGHT ELECTRONICS CO.,LTD.IRM-8751-1Package DimensionsNotes: 1.All dimensions are in millimeters. 2.Tolerances unless dimensions ±0.3mm.Absolute Maximum Ratings (Ta=25℃)Parameter Supply Voltage Operating Temperature Storage Temperature Soldering Temperature Symbol Vcc Topr Tstg Tsol Rating 0~6 -25 ~ +85 -40 ~ +85 260 Unit V ℃ ℃ ℃ 4mm from mold body less than 10 seconds NoticeEverlight Electronics Co., Ltd. Device No:DMO-870-003http:\\ Prepared date:07-23-2004Rev 1.2Page: 2 of 9Prepared by:CarryllHsu元器件交易网EVERLIGHT ELECTRONICS CO.,LTD.IRM-8751-1Recommended Operating ConditionSupply Voltage Rating: Vcc 4.5V to 5.5VElectro-Optical Characteristics (Ta=25℃, and Vcc=5 V)ParameterConsumption Current B.P.F Center FrequencySymbol Icc Fo λp L0 L45 Θh Θv TH TL VH VLMIN. ------8 4 ----400 400 4.5 ---TYP. --32.8 940 ----45 45 ------0.2MAX. 3 ------------800 800 --0.5Unit mA KHz nm m deg deg μs μs V VCondition No signal inputPeak Wavelength Reception Distance Half Angle(Horizontal) Half Angle(Vertical) High Level Pulse Width Low Level Pulse Width High Level Output Voltage Low Level Output VoltageAt the ray axis *1At the ray axis *2Notes: *1:The ray receiving surface at a vertex and relation to the ray axis in the range of θ= 0° and θ=45°. *2:A range from 30cm to the arrival distance. Average value of 50 pulses.Everlight Electronics Co., Ltd. Device No:DMO-870-003http:\\ Prepared date:07-23-2004Rev 1.2Page: 3 of 9Prepared by:CarryllHsu元器件交易网EVERLIGHT ELECTRONICS CO.,LTD.IRM-8751-1Test Method:The specified electro-optical characteristics is satisfied under the following Conditions at the controllable distance. Measurement place A place that is nothing of extreme light reflected in the room. External light Project the light of ordinary white fluorescent lamps which are not high Frequency lamps and must be less then 10 Lux at the module surface. (Ee≦10Lux) Standard transmitter A transmitter whose output is so adjusted as to Vo=400mVp-p and the output Wave form shown in Fig.-1.According to the measurement method shown in Fig.-2 the standard transmitter is specified. However , the infrared photodiode to be used for the transmitter should be λp=940nm,∆λ=50nm. Also, photodiode is used of PD438B(Vr=5V). (Standard light / Light source temperature 2856°K). Measuring system According to the measuring system shown in Fig.-3Fig.-1Transmitter Wave FormD.U.T output PulseCarrier frequency is adjusted to center frequency of each product.OUTPUT PULSE OF DEVICEIR TANSMITTER OUTPUT WAVE FORMDuty=0.5Everlight Electronics Co., Ltd. Device No:DMO-870-003http:\\ Prepared date:07-23-2004Rev 1.2Page: 4 of 9Prepared by:CarryllHsu元器件交易网EVERLIGHT ELECTRONICS CO.,LTD.IRM-8751-1Fig.-2Measuring Method20cm 10k +5.0± 0.1VFig.-3Measuring SystemL: Transmission Distance10uFθ θVcc OUT D.U.TVoutStandard TransmitterStandard Transmitter100kVout GNDOscilloscopeθ: Angle Of Horizontal & Vertical DirectionBlock Diagram:Application Circuit:RC Filter should be connected closely between Vcc pin and GND pin.Everlight Electronics Co., Ltd. Device No:DMO-870-003http:\\ Prepared date:07-23-2004Rev 1.2Page: 5 of 9Prepared by:CarryllHsu元器件交易网EVERLIGHT ELECTRONICS CO.,LTD.IRM-8751-1Typical Electro-Optical Characteristics CurvesFig.-4 Relative Spectral Sensitivity vs. Wavelength Fig.-5 Relative Transmission Distance vs. DirectionθFig.-6 Output Pulse Length vs. Arrival DistanceFig.-7 Arrival Distance vs. Supply VoltageEverlight Electronics Co., Ltd. Device No:DMO-870-003http:\\ Prepared date:07-23-2004Rev 1.2Page: 6 of 9Prepared by:CarryllHsu元器件交易网EVERLIGHT ELECTRONICS CO.,LTD.IRM-8751-1Typical Electro-Optical Characteristics CurvesFig.-8 Relative Transmission Distance vs. Center Carrier Frequency Fig.-9 Arrival Distance vs. Ambient Temperature12.5 10.0 7.5 5.0 2.5Everlight Electronics Co., Ltd. Device No:DMO-870-003http:\\ Prepared date:07-23-2004Rev 1.2Page: 7 of 9Prepared by:CarryllHsu元器件交易网EVERLIGHT ELECTRONICS CO.,LTD.IRM-8751-1Reliability Test Item And ConditionThe reliability of products shall be satisfied with items listed below. Confidence level:90% LTPD:10% Test Items Test Conditions 1 cycle Temperature cycle -25℃ +85℃ n=22,c=0 Failure Judgement Criteria Samples(n) Defective(c)(30min)(5min)(30min) 300 cycle test Temp: +85℃High temperature test Vcc:5V 1000hrs Low temperature storage High temperature High humidity Temp: -40℃ 1000hrs Ta: 85℃,RH:85% 1000hrs Temp: 260±5℃ 10sec 4mm From the bottom of the package.L0≦ L×0.8 L45≦ L×0.8n=22,c=0n=22,c=0 L: Lower specification limit n=22,c=0Solder heatn=22,c=0Everlight Electronics Co., Ltd. Device No:DMO-870-003http:\\ Prepared date:07-23-2004Rev 1.2Page: 8 of 9Prepared by:CarryllHsu元器件交易网EVERLIGHT ELECTRONICS CO.,LTD.IRM-8751-1Packing Quantity Specification1. 1000 PCS/1Box 2. 10 Boxes/1CartonLabel Form SpecificationCPN: Customer’s Production Number P/N : Production Number QTY: Packing Quantity CAT: Ranks HUE: Peak Wavelength REF: Reference LOT No: Lot NumberIRM-8608S-1Notes1. Above specification may be changed without notice. EVERLIGHT will reserve authority on material change for above specification. 2. When using this product, please observe the absolute maximum ratings and the instructions for using outlined in these specification sheets. EVERLIGHT assumes no responsibility for any damage resulting from use of the product which does not comply with the absolute maximum ratings and the instructions included in these specification sheets. 3. These specification sheets include materials protected under copyright of EVERLIGHT corporation. Please don’t reproduce or cause anyone to reproduce them without EVERLIGHT’s consent.EVERLIGHT ELECTRONICS CO., LTD. Office: No 25, Lane 76, Sec 3, Chung Yang Rd, Tucheng, Taipei 236, Taiwan, R.O.CTel: 886-2-2267-2000, 2267-9936 Fax: 886-2267-6244, 2267-6189, 2267-6306 http:\\Everlight Electronics Co., Ltd. Device No:DMO-870-003http:\\ Prepared date:07-23-2004Rev 1.2Page: 9 of 9Prepared by:CarryllHsu。

相关文档
最新文档