华为S2700交换机详版彩页
S2700配置指南-基础配置
2.1 首次登录系统简介......................................................................................................................................................19 2.2 通过 Console 口登录设备...........................................................................................................................................19 2.3 配置举例......................................................................................................................................................................24 2.3.1 配置首次登录设备后进行基本配置的示例...........................................................................................................24
华为S2700 S3700系列 01-01 接口基础配置
文档版本 07 (2020-04-15)
版权所有 © 华为技术有限公司
7
背景信息
对接口进行基本配置前,需要进入接口视图。
操作步骤
步骤1 执行命令system-view,进入系统视图。 步骤2 执行命令interface interface-type interface-number,进入接口视图。
其中,interface-type为接口类型,interface-number为接口编号。
3
S2700, S3700 系列以太网交换机 配置指南-接口管理
接口类型 NULL接口
1 接口基础配置
描述 因为任何送到该接口的网络数据报文都会被丢弃,主要用 于路由过滤等特性。
1.3 配置接口基本参数
配置接口基本参数,包括接口描述信息、接口流量统计时间间隔功能以及开启或关闭 接口。
1.3.1 进入接口视图
表 1-2 物理接口编号规则
接口编排规则示意图
2 4 6 ... ...
1 3 5 ...
说明
设备有两排业务接口,左下接口从1起 始编号,依据从下到上,再从左到右 的规则依次递增编号。 例如,左上第一个接口编号为0/0/2。
1.2 接口分类
您可以了解到设备支持的管理接口、物理接口和逻辑接口。
接口是设备与网络中的其它设备交换数据并相互作用的部件,分为管理接口、物理业 务接口和逻辑接口三类,其中:
1.3 配置接口基本参数 配置接口基本参数,包括接口描述信息、接口流量统计时间间隔功能以及开启或关闭 接口。
1.4 维护接口 您可以通过清除接口统计信息以方便查询一定时间内接口的流量信息。
1.1 接口编号规则
通过本小节,您可以了解到设备的接口编号规则。
Huawei S5700-SI交换机详版彩页
产品外观
S5700-24TP-SI
• 20个10/100/1000Base-T,4个100/1000Base-X千兆Combo口 • 分交流供电和直流供电两种机型, 支持RPS 12V冗余电源 • 包转发率:36Mpps • 交换容量:256Gbps
S5700-24TP-PWR-SI
• 20个10/100/1000Base-T,4个100/1000Base-X千兆Combo口 • 可插拔双电源,交流供电 • 支持PoE+ • 包转发率:36Mpps • 交换容量:256Gbps
S5700-48TP-SI
• 44个10/100/1000Base-T,4个100/1000Base-X千兆Combo口 • 分交流供电和直流供电两种机型,支持RPS 12V冗余电源 • 包转发率:72Mpps • 交换容量:256Gbps • 44个10/100/1000Base-T,4个100/1000Base-X千兆Combo口 • 可插拔双电源,交流供电 • 支持PoE+ • 包转发率:72Mpps • 交换容量:256Gbps
PoE特性
• S5700-SI PWR全系列交换机支持完善的PoE解决方案,用户可灵活配置PoE端口是否供电以及何时供 电。 • S5700-SI PWR全系列交换机可以通过配置不同功率等级的PoE电源支持PoE(Power over Ethernet) 功能 , 即可通过网线向远端下挂设备 ( 如 IP Phone 、 WLAN AP 、 Security 、 Bluetooth AP 等 ) 提 供-48V直流电源。作为供电方PSE(Power Sourcing Equipment)设备,支持IEEE802.3af及802.3at (PoE+)供电标准,同时兼容不符合802.3af及802.3at标准的PD(Powered Device)设备,并支持 绿色PoE节电应用模式。其中802.3at单端口供电功率高达30W,方便接入更大功率的终端。
S2700, S3700 V100R006C05 配置指南-接口管理
S2700, S3700 系列以太网交换机V100R006C05配置指南-接口管理文档版本07发布日期2020-04-15版权所有 © 华为技术有限公司 2020。
保留一切权利。
非经本公司书面许可,任何单位和个人不得擅自摘抄、复制本文档内容的部分或全部,并不得以任何形式传播。
商标声明和其他华为商标均为华为技术有限公司的商标。
本文档提及的其他所有商标或注册商标,由各自的所有人拥有。
注意您购买的产品、服务或特性等应受华为公司商业合同和条款的约束,本文档中描述的全部或部分产品、服务或特性可能不在您的购买或使用范围之内。
除非合同另有约定,华为公司对本文档内容不做任何明示或默示的声明或保证。
由于产品版本升级或其他原因,本文档内容会不定期进行更新。
除非另有约定,本文档仅作为使用指导,本文档中的所有陈述、信息和建议不构成任何明示或暗示的担保。
华为技术有限公司地址:深圳市龙岗区坂田华为总部办公楼邮编:518129网址:https://前言读者对象本文档介绍了设备支持的各种接口的基本概念及其配置方法。
本文档主要适用于以下工程师:●数据配置工程师●调测工程师●网络监控工程师●系统维护工程师符号约定在本文中可能出现下列标志,它们所代表的含义如下。
命令行格式约定接口编号约定本手册中出现的接口编号仅作示例,并不代表设备上实际具有此编号的接口,实际使用中请以设备上存在的接口编号为准。
目录前言 (ii)1 接口基础配置 (1)1.1 接口编号规则 (1)1.2 接口分类 (2)1.3 配置接口基本参数 (4)1.3.1 进入接口视图 (4)1.3.2 配置接口描述信息 (4)1.3.3 配置流量统计时间间隔 (5)1.3.4 配置开启或关闭接口 (5)1.3.5 检查配置结果 (6)1.4 维护接口 (6)1.4.1 清除统计信息 (7)2 以太网接口配置 (8)2.1 规格 (8)2.2 以太网接口简介 (9)2.3 缺省配置 (10)2.4 配置端口组 (11)2.5 配置以太网接口 (11)2.5.1 配置Combo接口工作模式 (11)2.5.2 配置MDI类型 (12)2.5.3 配置电缆检测 (13)2.5.4 配置自协商功能 (14)2.5.5 配置双工模式 (14)2.5.6 配置接口速率 (15)2.5.7 配置流量控制 (16)2.5.8 配置端口隔离 (17)2.5.9 配置允许超大帧通过 (18)2.5.10 配置上报状态变化延时时间 (19)2.5.11 配置出/入带宽利用率日志和告警阈值 (19)2.5.12 配置只允许PPPoE报文通过 (20)2.5.13 配置包括帧间隙和前导码的流量统计 (20)2.5.14 配置接收的错误报文超过阈值触发Error-down (20)2.5.15 检查配置结果 (21)2.6 维护以太网接口 (22)2.6.1 配置环回检测功能 (22)2.6.2 清除统计信息 (22)2.7 配置举例 (23)2.7.1 配置端口隔离示例 (23)2.8 常见配置错误 (25)2.8.1 两端接口双工、速率、协商模式配置不一致 (25)3 逻辑接口配置 (26)3.1 逻辑接口简介 (26)3.2 配置Loopback接口 (27)3.3 配置NULL接口 (28)1接口基础配置关于本章通过了解常见接口类型、接口编号规则以及各种可配置的接口参数等内容,方便用户对接口进行管理。
S2700系列以太网交换机的应用
S2700系列以太⽹交换机的应⽤S2700系列以太⽹交换机基于新⼀代交换技术和华为VRP(Versatile RoutingPlatform)软件平台,能提供简单便利的安装维护⼿段,同时融合了灵活的⽹络部署、丰富的QoS和安全控制策略、完备的⾼可靠机制、绿⾊环保等先进技术,可满⾜以太⽹多业务承载和接⼊需要,助⼒企业⽤户搭建⾯向未来的IT⽹络,来满⾜企业⽹对多业务可靠接⼊和⾼质量传输的要求。
产品特点S2700 定位于企业⽹接⼊层,具有⼤容量、⾼密度、⾼性价⽐的分组转发能⼒。
借助S2700 可构建⾼可靠的环形⽹络拓扑,具有多业务接⼊能⼒、良好的扩展性、QoS(Quality of Service)、强⼤的组播复制能⼒和运营级的安全性。
S2700 提供10/100BASE-T 以太⽹电接⼝和100/1000BASE-X 以太⽹光接⼝,⽀持Access、Trunk 和Hybrid 等多种接⼝类型,对于千兆光纤连接,提供可插拔的SFP(Small Form-Factor Pluggable)类型光模块。
光纤长度可以根据⽤户对传输距离的需求灵活选配。
可以组成树状、星型和环状以太⽹,对于环状以太⽹,提供STP(SpanningTree Protocol),消除环路并提供快速保护倒换。
S2700拥有⾃主知识产权的VRP(Versatile Routing Platform)平台为基础,结合设备和⽹络管理技术,提供⾼速的交换能⼒和丰富的业务特性,保障设备和数据传输的安全,有效的防⽌恶意⽤户对⽹络的攻击, 还提供安全的⽤户登录操作保护。
S2700 采⽤多种绿⾊节能措施,采⽤⾃然散热,节省风扇功耗,当检测不到业务端⼝对端连接设备,即端⼝空闲,则芯⽚进⼊省电模式,以减⼩功耗,采⽤先进⼯艺、⾼集成度、低功耗芯⽚,并配合智能设备管理系统充分利⽤芯⽚的低功耗特性,在提升系统性能的同时还降低了整机功耗,⽆噪声污染,避免定期维护风扇,节省维护费⽤,系统⽆风扇等额外功耗,使产品达到更好的能效功耗⽐,采⽤华为专利内置防雷技术,可降低设备在雷击天⽓中的损坏概率,⼤⼤提⾼设备可靠性,将安全系数提⾼30 倍。
华为S2700 S3700系列交换机 01-02 VLAN配置
2 VLAN配置关于本章VLAN具有隔离广播域、增强保密性、组网灵活和扩展性良好等特点。
2.1 VLAN概述介绍VLAN的定义、由来和作用。
2.2 设备支持的VLAN特性设备支持的VLAN特性包括VLAN的划分、VLAN间的通信、VLAN聚合、MUX VLAN、管理VLAN。
2.3 缺省配置介绍了VLAN参数的缺省配置。
2.4 划分VLAN创建并划分VLAN,将没有互通需求的用户进行隔离,增强网络的安全性、减少广播流量,同时也减少了广播风暴的产生。
2.5 配置VLANIF接口实现VLAN间的通信VLANIF接口是三层逻辑接口,在设备上创建VLANIF接口后,可实现VLAN间的通信。
2.6 配置VLAN聚合节约IP地址VLAN聚合解决了IP地址资源浪费问题,同时可实现不同VLAN间通信。
2.7 配置MUX VLANMUX VLAN可实现VLAN间通信,也可实现VLAN内的用户相互隔离。
2.8 配置管理VLAN实现网管集中管理设备配置管理VLAN功能,用户通过管理VLAN的VLANIF接口登录到管理交换机,实现网管集中管理设备。
2.9 维护VLAN维护VLAN,包括查看和清除VLAN的统计信息。
2.10 配置举例介绍VLAN的配置举例。
配置示例中包括组网需求、配置思路、操作步骤等。
2.11 常见配置错误介绍VLAN常见配置错误的处理方法。
2.1 VLAN概述介绍VLAN的定义、由来和作用。
VLAN(Virtual Local Area Network)即虚拟局域网,是将一个物理的LAN在逻辑上划分成多个广播域的通信技术。
以太网是一种基于CSMA/CD(Carrier Sense Multiple Access/Collision Detection)的共享通讯介质的数据网络通讯技术。
当主机数目较多时会导致冲突严重、广播泛滥、性能显著下降甚至造成网络不可用等问题。
通过交换机实现LAN(Local AreaNetwork)互连虽然可以解决冲突严重的问题,但仍然不能隔离广播报文和提升网络质量。
Huawei S5700-SI交换机详版彩页
• 可插拔双电源,支持交流或者直流供电 • 包转发率:132Mpps • 交换容量:256Gbps
S5700-52C-PWR-SI 产品特性和优势
• 48个10/100/1000Base-T,上行支持4×1000Base-X SFP、 2×10GE SFP+、4×10GE SFP+插卡
12*10/100/1000 BASE-T, 12*100/1000 Base-X, 2*10GE SFP+口
描
述扩
展 S5700TP系列提供一个堆叠扩展插槽
48*10/100/1000 Base-T, 4个复用SFP 千兆Combo SFP
48*10/100/ 1000Base-T
插 S5700C系列产品提供两个扩展插槽,分别支持上行插卡和堆叠卡
S5700-48TP-SI-AC S5700-48TP-SI-DC
• 24个10/100/1000Base-T以太网端口,4个复用的千兆Combo SFP
• 可插拔双电源,交流供电 • 支持PoE+ • 包转发率:36Mpps • 交换容量:256Gbps
• 12个10/100/1000BASE-T,12个100/1000Base-X,2个10GE SFP+口 (支持自适应为GE光口)
• S5700-SI支持SmartLink功能。S5700-SI通过多条链路接入到多台汇聚交换机上,SmartLink实现了上 行链路的备份,极大地提升了接入侧设备的可靠性。
• S5700-SI支持完善的以太OAM(IEEE 802.3ah/802.1ag),用于快速检测链路故障。
华为S2700 S3700系列交换机 01-08 CFM配置
8.4.3 创建维护域 MD
背景信息
在所有需要实施以太网CFM管理的设备上进行以下配置。
操作步骤
步骤1 执行命令system-view,进入系统视图。
步骤2 执行命令cfm md md-name [ format { no-md-name | dnsname-and-mdname | mac-address | md-name } ] [ level level ],创建MD并进入MD视图。
根据网络的分层/分级架构,需要提供分层/分级的以太OAM功能。如图8-1所示。
图 8-1 以太网 OAM 示意图 Services Access
Metro
CE
PE1
P
PE2
PE3
Core
Access Link OAM
Connectivity Layer OAM
Service Layer OAM
EFM
缺省情况下,设备的全局CFM功能处于未使能状态。 ----结束
8.4.2 版本切换
背景信息
缺省情况下,设备启用的是802.1ag协议draft7草案版本。如果需要使用standard2007 标准版本,在所有需要切换版本的设备上进行system-view,进入系统视图。 步骤2 执行命令cfm version { draft7 | standard },切换版本。
8 CFM 配置
组网类别 映射原则
端到端链路
当MA部署在端到端组网中时如MA2,需要MA与业务实例关联。但是 不同的网络层次,维护集MA与业务实例的关联方式不同。如图8-2所 示:
华为S2700 S3700系列交换机 01-09 监控口配置
9监控口配置关于本章通过配置监控口,可以实现对设备的使用环境进行监控,方便管理员对设备进行维护。
9.1 监控口简介介绍监控口的定义和目的。
9.2 配置注意事项介绍监控口特性的注意事项及设备支持的监控口。
9.3 配置监控口介绍监控口的详细配置过程。
9.4 配置举例介绍监控口配置举例。
配置示例中包括组网需求、配置思路等。
9.1 监控口简介介绍监控口的定义和目的。
定义监控口是位于设备上用于监控机柜门、设备电源、电池电量和空调电源等设备的接口。
目的在某些应用场景中,如交换机部署在接入侧作为楼道交换机实现宽带用户接入,因为楼道应用环境的特殊性,交换机需要安装在定制的机箱内,机箱内配置了备用电源。
由于这些设备与网络管理员所在的中心机房距离较远,当这些设备发生故障时,由于设备无法主动上报故障,导致网络管理员无法及时感知。
为了解决这个问题,交换机提供了环境监控接口,连接机柜门、备用电源等设备,当机箱门、备用电源等设备应用状况异常时,交换机发送Trap至网管站,实现对交换机应用环境的监控。
图9-1监控口应用示意图机柜门备用电源电池电量空调电源9.2 配置注意事项介绍监控口特性的注意事项及设备支持的监控口。
监控口特性的注意事项只有S3700-28TP-EI-MC支持此特性。
设备支持的监控口设备提供两个监控口,一个为监控输入口,另外一个为监控输出口。
●监控输入口:监控输入口为普通的以太网接口,提供4条输入线路,用来监控4种不同的源,例如机柜门、设备电源、电池电量和空调电源等设备(具体监控的设备由用户决定,可以监控但不限于上述设备)。
以直通网线为例,如图9-2所示,线序为:橙白、橙、绿白、蓝、蓝白、绿、褐白、褐。
每两根线为一路输入线路,这样依次橙白、橙为1号输入线路;绿白、绿为2号输入线路;蓝白、蓝为3号输入线路;褐白、褐为4号输入线路。
橙白、绿白、蓝白、褐白线要求连接到被监控设备的一个电平可变的端子上,被监控设备状态变化时,该端子的电平会由高变低或由低变高。
华为S2700 S3700系列交换机 01-08 连接交换机
8连接交换机8.1 连接电源线缆8.2 连接网线8.3 连接光纤8.4 连接高速电缆8.5 连接堆叠线缆8.1 连接电源线缆背景信息严禁带电连接电源线缆,以免造成人身伤害。
●连接前请做好防静电保护措施,如佩戴防静电腕带或防静电手套。
●电源线严禁从户外架空引入,必须全程埋地或室内走线。
●严禁在交换机安装和布线完成前向交换机供电。
●产品包装内的电源线作为随设备发货的附件之一,只可与本包装内的主机配套使用,不可用于其他设备上。
S2700&S3700&S5700&S6700系列交换机使用的电源分为内置电源、可插拔的电源模块或独立的电源模块,使用不同电源时所需的电源线缆和连接方法不同:非S5720I-SI系列交换机:●如果外部供电系统提供的是交流制式插座,交换机需为内置交流电源或使用交流电源模块,配套使用当地制式的交流电源线缆。
●如果外部供电系统提供的是交流PDU,交换机需为内置交流电源或使用交流电源模块,配套使用C13直母-C14直公电源线缆。
●如果外部供电系统提供的是直流配电盒,交换机需为内置直流电源或使用直流电源模块,配套使用直流电源线缆。
说明各国家/地区使用的交流电源线缆参数不同,线缆外观以实际发货为准,本文中的图示仅作为举例说明。
对于使用直流电源的交换机安装在工作台的场景,如果自行选配直流电源线,电源线的外径需不大于2.1mm且导体截面积为1mm2,建议选用18 A.W.G UL1007规格的电源线。
如果是S5720I-SI系列交换机和PAC-260WA-E或PAC240S56-CN电源模块,需使用凤凰端子和配套的电源线缆。
准备工具和附件●防静电腕带或防静电手套●十字螺丝刀●(可选)交流端子防脱扣●(可选)剥线钳操作步骤步骤1佩戴防静电腕带或防静电手套。
如果佩戴防静电腕带,需确保防静电腕带一端已经接地,另一端与佩戴者的皮肤良好接触。
步骤2断开给交换机供电的外部电源开关。
步骤3断开交换机或电源模块上的电源开关。
华为S2700-9TP-SI(AC)
华为S2700-9TP-SI(AC)参数规格产品类型百兆以太网交换机应用层级二层传输速率10/100Mbps 交换方式存储-转发背板带宽32Gbps 包转发率2.7Mpps MAC地址表8K 端口结构非模块化端口数量9个端口描述8个10/100Base-TX端口,1个千兆Combo口传输模式全双工/半双工自适应网络标准IEEE 802.3,IEEE 802.3u ,IEEE 802.3ab ,IEEE 802.3z ,IEEE 802.3x ,IEEE 802.1Q ,IEEE 802.1d ,IEEE 802.1X堆叠功能可堆叠支持IEEE 802.1Q(VLAN),整机支持4K个VLAN 支持基于端口的VLAN支持端口限速和流限速支持每端口4个不同优先级的队列支持根据报文802.1p映射到不同队列支持SP、WRR、SP+WRR算法支持IGMP v1/v2/v3 Snooping支持捆绑端口的组播负载分担支持基于端口的组播流速率限制和流量统计支持端口1:1或N:1镜像支持堆叠支持自动配置功能支持CLI配置支持Telnet远程配置支持SNMP V1/V2/V3支持RMON支持集群管理HGMP V2主要参数端口参数功能特性VLANQOS组播管理网络管理支持SSH V2支持WEB管理特性支持GVRP协议支持802.1x,支持单端口最大用户数限制支持动态ARP检测支持IP Source Guard功能支持AAA认证,支持Radius、HWTACACS+、NAC等多种方式支持IP、MAC、端口、VLAN的组合绑定支持端口限速支持端口隔离、端口安全、Sticky MAC支持包过滤支持MAC地址过滤支持多播、广播及未知单播报文抑制支持MAC地址学习数目限制支持CPU保护功能支持端口隔离支持多播、广播及未知单播报文抑制支持CPU保护功能电源电压AC 100-240V 电源功率<12.8W 产品尺寸250×180×43.6mm 产品重量<1.4kg工作温度:0-50℃工作湿度:10%-90%存储温度:-5-55℃存储湿度:10%-90%环境标准其它参数安全管理。
华为S2700-26TP-SI(AC)
华为S2700交换机设置1.用交换机自带数据线。
COM连接电脑,网口连接交换机comsole口.2.运行软件选择serial。
波特率:9600奇偶校验:无奇偶停止位:1去掉RTS/CTS的勾选项3.建立连接。
回车4.输入密码:huawei123回车5.再次输入密码:huawei123回车6. 输入SYS回车7.观察网络格式,输入:dis stp回车8. 更改网络格式为rstp。
输入:stp mode rstp回车9. 输入:dis stp回车10.保存设置,输入:save回车11.重启。
输入:reboot回车华为st2700-26tp-si-ac 以太网交换器配置介绍<Quidway>系统查看模式<Quidway>sys 进入系统配置模式[Quidway]1.更改设备名称[Quidway]sysname bzyzbq-1 (设备名称《Quidway》更改bzyzbq-1[bzyzbq-1]设备名称已经更改为bzyzbq-12.现在设置用户名和密码[bzyzbq-1]aaa[bzyzbq-1-aaa]local-user bzyzschool password simple bz1zbqmanager (建立用户名:bzyzschool ,密码:bz1zbqmanager)3.建立用户权力[bzyzbq-1-aaa]local-user bzyzschool privilege level 15 (用户名:bzyzschool)4.给用户服务类型[bzyzbq-1-aaa]local-user bzyzschool service-type telnet web (用户名:bzyzschool)5.密码显示[bzyzbq-1-aaa]local-user bzyzschool password simple bz1zbqmanager(密码显示)6.开虚拟终端[bzyzbq-1-aaa]quit (先退去认真模式)[bzyzbq-1]user-interface vty 0 4 (开虚拟终端)[bzyzbq-1-ui-vty0-4]quit (退去)[bzyzbq-1]7.认真模式[bzyzbq-1-ui-vty0-4]authentication-mode aaa8.建立管理VLAN 0 的名称[bzyzbq-1][bzyzbq-1]interface vlan 1[bzyzbq-1-Vlanif1]description manager (已经建立管理VLAN 1 的名称manager) 9.建立管理IP 地址[bzyzbq-1-Vlanif1]ip address 10.1.0.124 255.255.255.010.开通道端口先打开第一通道[bzyzbq-1]interface GigabitEthernet 0/0/1 (进入通道端口)[bzyzbq-1-GigabitEthernet0/0/1]port link-type trunk (trunk是开通)[bzyzbq-1-GigabitEthernet0/0/1]port trunk allow vlan all (开通全部VLAN )然后开第二个通道[bzyzbq-1]interface GigabitEthernet 0/0/2 (进入通道端口)[bzyzbq-1-GigabitEthernet0/0/2]port link-type trunk (trunk是开通)[bzyzbq-1-GigabitEthernet0/0/2]port trunk allow vlan all (开通全部VLAN ) 11.建立VLAN[bzyzbq-1]vlan 123 (123是VLAN ID号)[bzyzbq-1-vlan123](进入VLAN 123)12.给vlan 123 的名称[bzyzbq-1-vlan123]description arman (VLAN 123的名称是arman)13.其它vlan也是一样11 与12一样建立14.进入VLAN[bzyzbq-1]interface vlan 123[bzyzbq-1-Vlanif123]q14.设置24个端口开第一端口开[bzyzbq-1]interface Ethernet 0/0/1 (进入端口一)[bzyzbq-1-Ethernet0/0/1]port link-type access第二端口开[bzyzbq-1]interface Ethernet 0/0/2 (进入端口二)[bzyzbq-1-Ethernet0/0/2]port link-type access弟三........第24端口开方法是第一和第二端口一样15.每个端口给VLAN[bzyzbq-1]interface Ethernet 0/0/1 (先进普通端口)[bzyzbq-1-Ethernet0/0/1]port default vlan 123(第一端口绑定VLAN 123)16.如果再需要建立VLAN 然后绑定先建立VLAN 例如建立vlan 130([bzyzbq-1]VLAN 130 然后进入[bzyzbq-1-Vlan 130]如果退去请按q 然后退去[bzyzbq-1]然后给命令interface vlan 130也进入[bzyzbq-1-Vlanif130]17.再普通端口绑定VLAN ID 号第15条一样建立18.如果删除VLAN ID 号[bzyzbq-1]undo interface vlan id (就好了)19.保存当前的配置<bzyzbq-1>save然后问您选:Y/N 我们选y 然后回车20.重启交换器<bzyzbq-1>reboot然后问您选:Y/N 我们选y 然后回车21.出厂恢复<bzyzbq-1>reset saved然后选择Y,然后重启命令<bzyzbq-1>reboot然后选择N,然后选择Y,就行全部恢复出厂设置OK22.如果第一交换器连接以太网,第二个交换器连接第一个交换器设置如下:第一交换器的第一通道端口连接以太网,第二个交换器的第一个通道端口连接第一个交换器的第二个通道是:第一交换器包括第二个交换器的全部VLAN id号和第一个交换器的的全部VLAN id 号23.智能路由交换机7706查看命令:dis curr 查看所有dis vlan dis interface 查看端口智能交换机S2700 26TP dis save 查看保存dis th 查看当前计算机MAC地址查询方法:进入MS-DOS或者使用运行输入CMD。
Quidway S5700 系列交换机V100R005C01产品彩页V1.0
Quidway® S5700系列全千兆企业网交换机产品概述Quidway® S5700系列全千兆企业网交换机(以下简称S5700),是华为公司为满足大带宽接入和以太网多业务汇聚而推出的新一代绿色节能的全千兆高性能以太网交换机。
它基于新一代高性能硬件和华为公司统一的VRP®(Versatile Routing Platform)平台,具备大容量、高密度千兆端口,可提供万兆上行,充分满足客户对高密度千兆和万兆上行设备的需求,同时针对企业网用户的园区网接入、汇聚、IDC千兆接入以及千兆到桌面等多种应用场景,融合了可靠、安全、绿色环保等先进技术,采用简单便利的安装维护手段,帮助客户减轻网络规划、建设和维护的压力,助力企业搭建面向未来的IT网络。
S5700系列以太网交换机为盒式设备,机箱高度为1U,提供标准型(SI)和增强型(EI)两种产品版本。
标准型支持二层和基本的三层功能,增强型支持复杂的路由协议和更为丰富的业务特性,包含型号如下:S5700-24TP-SI-AC/DC、S5700-24TP-PWR-SI、S5700-48TP-SI-AC/DC、S5700-48TP-PWR-SI、S5700-28C-SI、S5700-28C-EI、S5700-28C-EI-24S、S5700-28C-PWR-EI、S5700-52C-SI、S5700-52C-EI、S5700-52C-PWR-EI。
产品外观S5700系列交换机包括如下款型:S5700-28C-EI产品特点●强大的多业务支持能力S5700支持IGMP v1/v2/v3 Snooping/Filter/Fast Leave/Proxy等协议。
S5700支持线速的跨VLAN组播复制功能,支持捆绑端口的组播负载分担,支持可控组播,可以充分满足IPTV和其他组播业务的需求。
S5700支持MCE 功能,实现了不同VPN用户在同一台设备的隔离,有效解决用户数据安全问题,同时降低用户投资成本。
华为S5700-EI系列交换机产品彩页
S5700-EI系列增强型千兆以太交换机S5700-EI 系列增强型千兆以太交换机产品概述1华为企业Sx700系列交换机产品特点更多的端口组合• S5700-EI支持多种上行扩展插卡,提供高密度的GE/10GE上行接口。
其中S5710-EI系列具有4 个固定10GE SFP+端口,通过上行扩展插卡可实现64×GE+4×10GE,48×GE+8×10GE,或56×GE+6×10GE等不同端口组合,充分满足不同用户对带宽升级的实际需求,保护用户投资。
完善的VPN隧道• S5700-EI支持Multi-VPN-Instance CE(MCE)功能。
S5700-EI支持下接不同的VPN用户,通过路由多实例,实现了不同用户的隔离;上行通过共用的物理接口连接到PE设备,减少单个VPN用户对网络部署的投资。
• S5710-EI支持MPLS L3VPN、MPLS L2VPN(VPWS\VPLS)、MPLS-TE、MPLS QoS等功能,可作为高质量企业专线接入设备,是业界为数不多的高性价比盒式MPLS交换机。
灵活的以太组网• S5700-EI不仅支持传统的STP/RSTP/MSTP生成树协议,还支持华为自主创新的SEP 智能以太保护技术和业界最新的以太环网标准ERPS。
SEP是一种专用于以太链路层的环网协议,适用于半环、整环、级连环等各种组网,其协议简单可靠、维护方便,并提供50ms的快速业务倒换。
ERPS是ITU-T发布的G.8032标准,该标准基于传统的以太网MAC和网桥功能,实现以太环网的毫秒级快速保护倒换。
2华为企业Sx700系列交换机• S5700-EI支持SmartLink和VRRP功能。
S5700-EI通过多条链路接入到多台汇聚交换机上,SmartLink/ VRRP实现了上行链路的备份,极大地提升了接入侧设备的可靠性。
• S5700-EI支持多种连接故障快速检测功能。
华为S2700 S3700系列交换机 01-12 配置举例
12.4 配置 MSTP 的基本功能示例
介绍配置MSTP的基本功能示例。
组网需求
本例中的交换机都使用二层接口运行MSTP。需求如下:
文档版本 07 (2020-04-15)
版权所有 © 华为技术有限公司
213
S2700, S3700 系列以太网交换机 Web 网管操作指南
12 配置举例
操作结果
d. 单击“确定”。 ● 将接口Ethernet0/0/4加入VLAN3
a. 单击导航树中的“业务管理 > VLAN > Hybrid口”菜单,进入“Hybrid口” 界面。
组网需求
如图12-1所示,某企业包含4个部门。部门1通过Switch1与Switch的接口Eth0/0/1相 连。部门2通过LSW-A与Switch的接口Eth0/0/2相连。部门3通过LSW-B与Switch的接 口Eth0/0/3相连。部门4通过Switch2与Switch的接口Eth0/0/4相连。要求:
b. 在“Hybrid口”页面,单击接口“Ethernet0/0/1”后对应的“ ”图标,进 入“修改接口的VLAN配置”界面。
c. 输入“Tagged”为“2”。 d. 单击“确定”。
说明
所有接口默认的链路类型是hybrid,如果需要配置的接口已经修改了链路类型,需要把它 们转换为hybrid口再进行配置。
● 在域RG2内,SwitchB为CIST域根,SwitchB为实例1的域根。
● SwitchC和SwitchD的Ethernet0/0/2接口与PC机相连,设置为边缘端口,同时在 SwitchC和SwitchD上应用BPDU保护功能。
QuidwayS2700系列交换机V100R005C01产品彩页V10
QuidwayS2700系列交换机V100R005C01产品彩页VlO产品概述Quidway® S2700系列企业网交换机(下列简称S2700)是华为公司推出的新一代绿色节能的以太网智 能百兆接入交换机。
它基于新一代交换技术与华为VRP® (Versatile Routing Platform)软件平台,针 对企业客户的各类应用场景,提供简单便利的安装保护手段,同时融合了灵活的VLAN 部署、完备的安全 与Q 。
S 操纵策略、绿色环保等先进技术,可满足以太网多业务承载与接入需要,助力企业用户搭建面向未 来的IT 网络。
S2700为盒式产品设备,机箱高度为1U,提供标准型(SI)与增强型(EI)两种产品版本。
包含 S2700-9TP-EI 、 S2700-9TP-SI 、 S2700-18TP-EK S2700T8TP-SI 、 S2700-26TP-EI> S2700-26TP-SI 、 S2700-52P-Ek S2700-9TP-PWR-Ek S2700-26TP-PWR-EIo产品型号与外观Quidway® S2700系列包含下列交换机:S2700-9TPS2700-18TP-SI-ACV<M>W ・里・S2700-9TP-EI-AC S2700-9TP-SI-ACS2700-18TP・8 个 10/100BaSeTX , 1 个千兆 Combo 口 (10∕100∕1000Base -T 或者 100∕1000Base -X)•EI 分交流供电与直流供电两种机型,SI 只有交流机型 •8 个 10∕100Base -TX , 1 个千兆 Combo 口 (10∕100∕1000Base -T 或者 100/IOOOBase-X)• 交流供电 •支持POE÷•16 个 10/IOOBase-TX , 2 个千兆 Combo 口 (10∕100∕1000Base -T 或者 100/1000BaSe-X ),• 交流供电S2700-9TP-PWR-EI.S2700-18TP-EI-AC・ 48 个 10∕100Base -TX, 2 个 100/IOOOBase-X SFP, 2个 K)OOBa$e-X SFP,• 交流供电产品特性与优势•免保护,易部署,易管理S2700支持自动配置,智能式即插即用,大大降低初始安装成本;使用全新交换ASlC 技术,整机无 风扇设计,减少机械故障点的同时免除凝露腐蚀与尘土侵害,能有效降低主机53%保护率。
华为S2700系列企业交换机产品简介说明书
BrochureProduct OverviewThe S2700 utilizes cutting-edge switching technologies and Huawei Versatile Routing Platform (VRP) software to meet the demand for multi-service provisioning and access on Ethernet networks. It is easy to install and maintain. With its flexiblenetwork deployment, comprehensive security and quality of service (QoS) policies, and energy-saving technologies, the S2700 helps enterprise customers build next-generation IT networks.The S2700 is a box device that is 1 U (44.45 mm or 1.75 in.) high. It is available in a standard version (SI) or an enhanced version (EI).Models and AppearancesModels and AppearancesDescriptionS2700-9TP-SI-ACS2700-9TP-EI-ACS2700-9TP-EI-DC● 8 Ethernet 10/100 ports, 1 dual-purpose 10/100/1000 or SFP●AC and DC power supply for the EI version; AC power supply for the SI version ● Forwarding performance: 2.7 Mpps ●Switching Capacity: 32GbpsS2700-9TP-PWR-EI● 8 Ethernet 10/100 ports, 1 dual-purpose 10/100/1000 or SFP ●AC power supply ● PoE+● Forwarding performance: 2.7 Mpps ●Switching Capacity: 32GbpsS2700-18TP-SI-ACS2700-18TP-EI-AC●16 Ethernet 10/100 ports, 2 dual-purpose 10/100/1000 or SFP ● AC power supply● Forwarding performance: 5.4 Mpps ●Switching Capacity: 32GbpsS2700-26TP-SI-ACS2700-26TP-EI-AC●24 Ethernet 10/100 ports, 2 dual-purpose 10/100/1000 or SFP ● AC power supply for the EI version; AC power supply for the SI version ● Forwarding performance: 6.6 Mpps ●Switching Capacity: 32GbpsS2700-26TP-PWR-EI● 24 Ethernet 10/100 ports, 2 dual-purpose 10/100/1000 or SFP ●AC power supply ● PoE+● Forwarding performance: 6.6 Mpps ● Switching Capacity: 32GbpsS2710-52P-SI-AC●48 Ethernet 10/100 ports, 4 Gig SFP ● AC power supply● Forwarding performance: 13.2 Mpps ● Switching Capacity: 32GbpsS2700-52P-EI-AC●48 Ethernet 10/100 ports, 4 Gig SFP ● AC and DC power supply● Forwarding performance: 13.2 Mpps ● Switching Capacity: 32GbpsS2700-52P-PWR-EI● 48 Ethernet 10/100 ports, 4 Gig SFP ●AC power supply ● PoE+● Forwarding performance: 13.2 Mpps ● Switching Capacity: 32GbpsS2750-20TP-PWR-EI-AC●16 Ethernet 10/100 ports, 2 Gig SFP and 2 dual-purpose 10/100/1000 or SFP ● AC power supply ● PoE+● Forwarding performance: 8.4 Mpps ● Switching Capacity: 64GbpsS2750-28TP-EI-AC●24 Ethernet 10/100 ports, 2 Gig SFP and 2 dual-purpose 10/100/1000 or SFP ● AC power supply● Forwarding performance: 9.6 Mpps ● Switching Capacity: 64Gbps●24 Ethernet 10/100 ports, 2 Gig SFP and 2 dual-purpose 10/100/1000 or SFP ●AC power supplyS2750-28TP-PWR-EI-AC● PoE+● Forwarding performance: 9.6 Mpps ● Switching Capacity: 64GbpsS2720-28TP-EI-AC●24 Ethernet 10/100 ports,2 Gig SFP and 2 dual-purpose ● 10/100/1000 or SFP ● AC power supply● Forwarding performance: 9.6 Mpps ●Switching Capacity: 12.8GbpsFeatures and HighlightsEasy Operation● The S2700 supports Huawei Easy Operation function. Thanks to this function, the S2700 implements easy installation, configuration, monitoring, and troubleshooting, greatly reduces initial installation and configuration costs, improves upgrade efficiency and lowers engineering costs. It provides a Web network management system (NMS) with a user-friendly graphical user interface (GUI) to implement alarm management and visual configuration, facilitating operation and maintenance. In addition, it supports faulty device replacement without configuration.● The S2700 offers a new application-specific integrated circuit (ASIC) switching technique and a fan-free design. This design reduces mechanical faults and protects the device against damages caused by condensed water and dust.Flexible Service Control● The S2700-EI supports various ACLs. ACL rules can be applied to VLANs to flexibly control ports and schedule VLAN resources.● The S2700 supports port-based VLAN assignment, MAC address-based VLAN assignment, protocol-based VLANassignment, and network segment-based VLAN assignment. These secure and flexible VLAN assignment modes are used in networks where users move frequently.● The S2700 supports GARP VLAN Registration Protocol (GVRP), which dynamically distributes, registers, and propagates VLAN attributes to ensure correct VLAN configuration and reduce network administrator workloads. In addition, the S2700 supports SSH v2, HWTACACS, RMON, and port-based traffic statistics. The network quality analyzing (NQA) function assists users with network planning and upgrades.Excellent Security Features● The S2700 supports DHCP snooping, which generates user binding entries based on users' access interfaces, MAC addresses, IP addresses, IP address leases, VLAN IDs. The DHCP snooping function protects enterprises from common attacks such as bogus IP packet attacks, man-in-the-middle attacks, and bogus DHCP server attacks.● The S2700 can limit the number of MAC addresses that can be learned on an interface to prevent attackers fromexhausting MAC address entries by using bogus source MAC addresses. This function minimizes packet flooding, which occurs when users' MAC addresses cannot be found in the MAC address table. The S2700 can also limit the number of ARP entries to prevent ARP spoofing attacks. In addition, it provides an IP source check function to prevent malicious users from using spoofed IP addresses to initiate DoS attacks.● The S2700 supports centralized MAC address authentication and 802.1x authentication. It authenticates users based on statically or dynamically bound user information such as IP address, MAC address, VLAN ID, access interface. VLANs, QoS policies, and ACLs can be dynamically applied to users.PoE Function● The S2700 PWR series support improved Power over Ethernet (PoE) solutions and you can determine whether a PoE port provides power and the time a PoE port provides power. The S2700 PWR can use PoE power supplies with different power levels to provide the PoE function. Powered devices (PDs) such as IP Phones, WLAN APs, and Bluetooth APs can be connected to the S2700 PWR through network cables. The S2700 PWR provides -48V DC power for the PDs.●In its role as power sourcing equipment (PSE), the S2700 PWR complies with IEEE 802.3af and 802.3at (PoE+), and can work with PDs that are incompatible with 802.3af or 802.3at (PoE+). Each port provides a maximum of 30 W of power, complying with IEEE 802.3at. The PoE+ function increases the maximum power available on each port and implements intelligent power management for high-power consumption applications. This process facilitates the ease of PD use. PoE ports are still able to work while in power-saving mode.High Scalability●The S2700 uses Intelligent Stack (iStack) to virtualize multiple switches into a single logical device to ease user management and configuration and expand the system switching capacity. iStack improves switching capacity, reliability, and scalability. Additionally, after the stack is established, all the member switches in a stack use the same IP address. You can use a single IP address to manage and maintain the switches uniformly. This greatly reduces system operation and maintenance (O&M) costs.●The iStack stacking architecture is designed for rapid failover capability with n-1 master redundancy, distributed Layer 2 and Layer 3 switching, link aggregation across the stack, and within 200 millisecond failover for path failure and hitless master/backup failover.●Besides traditional STP, RSTP, and MSTP, the S2700 supports enhanced Ethernet technologies such as Smart Link and RRPP, implements millisecond-level protection switchover for links, and ensures the network quality.●The S2700 supports Smart Ethernet Protection (SEP) protocol, a ring network protocol applied to the link layer of an Ethernet network. SEP provides millisecond-level service switchovers and ensures nonstop forwarding of services. In addition, SEP features simplicity, high reliability, high switchover performance, convenient maintenance, and flexible topology and enables users to manage and plan networks conveniently.●The S2700 supports G.8032 Ethernet Ring Protection Switching (ERPS). The ERPS is based on traditional Ethernet MAC and bridging functions. It uses the mature Ethernet OAM and Ring Automatic Protection Switching (Ring APS or R-APS) technologies to implement millisecond-level protection switching on Ethernet. ERPS supports various services and flexible networking and lowers operating expense (OPEX) and capital expenditure (CAPEX) of users.Comprehensive QoS Policies●The S2700 supports complex traffic classification based on packets' TCP/UDP port numbers, VLAN IDs, source MAC/IP addresses, destination MAC/IP addresses, IP protocols, or priorities. By limiting the traffic rate based on traffic classification results, the S2700 implements line-speed forwarding on each port to ensure high-quality voice, video, and data services. Each port supports a maximum of eight queues and multiple queue scheduling algorithms, such as WRR, SP, and WRR+SP. Powerful Surge Protection Capability●The S2700 uses the Huawei patented surge protection technique that supports 7 kV surge protection capability on service ports. This effectively protects switches against over lightning induced overvoltage. The Huawei patented surge protection technique greatly reduces the possibility of equipment being damaged by lightning, even in extreme situations or in scenarios where grounding is not feasible.Quiet Operation, Energy Conservation, and Low Radiation●The S2700 uses an energy-saving integrated circuit design to ensure even heat dissipation. Idle ports can enter a sleep mode to further reduce power consumption. The S2700 generates no sound because it does not contain any fans. Radiation produced by the S2700 is within the standard range for electric appliances and causes no harm to the human body. Product SpecificationsDownlink ports ●S2700-9TP-SI: 810/100Base-TX Ethernetports●S2700-18TP-SI: 1610/100Base-TX Ethernetports●S2700-26TP-SI: 24 ●S2700-9TP-EI/S2700-9TP-PWR-EI: 8 10/100Base-TXEthernet ports●S2700-18TP-EI: 1610/100Base-TX Ethernetports●S2700-26TP-EI/S2700-●S2750-20TP-PWR-EI-AC: 1610/100Base-TX Ethernetports●S2750-28TP-EI-AC/S2750-28TP-PWR-EI-AC/ S2720-28TP-EI-AC: 24 10/100Base-TX Ethernet ports10/100Base-TX Ethernetports●S2710-52P-SI: 4810/100Base-TX Ethernetports26TP-PWR-EI: 2410/100Base-TX Ethernetports●S2700-52P-EI: 4810/100Base-TX EthernetportsUplink ports ●S2700-9TP-SI: 1 dual-purpose 10/100/1000 or SFP●S2700-18TP-SI/S2700-26TP-SI: 2 dual-purpose10/100/1000 or SFP●S2710-52P-SI: 4 Gig SFP ●S2700-9TP-EI/S2700-9TP-PWR-EI: 1 dual-purpose10/100/1000 or SFP●S2700-18TP-EI/S2700-26TP-EI/S2700-26TP-PWR-EI: 2 dual-purpose10/100/1000 or SFP●S2700-52P-EI: 4 Gig SFP●S2750-20TP-PWR-EI/S2750-28TP-EI-AC/S2750-28TP-PWR-EI: 2 Gig SFP and 2dual-purpose 10/100/1000 orSFP●S2720-28TP-EI-AC: 2 GigSFP and 2 dual-purpose10/100/1000 or SFPMAC address 8K MAC address entriesManual deletion of dynamicMAC address entriesAging time of MAC addressconfigurableBlackhole MAC address entries 8K MAC address entriesManual deletion of dynamic MACaddress entriesAging time of MAC addressconfigurableBlackhole MAC address entriesMAC address learning controlwhich based on ports16K MAC address entriesManual deletion of dynamic MACaddress entriesAging time of MAC addressconfigurableMAC address learning controlwhich based on portsBlackhole MAC address entriesVLAN feature 4K active VLANs, complyingwith IEEE 802.1QPort-based VLAN assignment 4K active VLANs, complying withIEEE 802.1QPort-based VLAN assignmentMAC address-based assignmentPort-based QinQ4K active VLANs, complying withIEEE 802.1QPort-based VLAN assignmentMAC address-based assignmentPort-based QinQQoS Outbound-Port-based ratelimiting and flow-based ratelimiting4 or 8 queues of differentpriorities on each portMapping between 802.1ppriorities and queuesSP, WRR, and SP+WRRalgorithms Port-based rate limiting and flow-based rate limiting4 or 8 queues of differentpriorities on each portMapping between 802.1ppriorities and queuesSP, WRR, and SP+WRRalgorithmsPort-based rate limiting and flow-based rate limiting8 queues of different priorities oneach portMapping between 802.1ppriorities and queuesSP, WRR, and SP+WRRalgorithmsPacket-based priority remarkand packet redirectionIPv4 routing Static routing Static routing Static routingRIP v1/v2(S2750-EI)IPv6 feature IPv6 protocolStatic IPv6 routes IPv6 protocolStatic IPv6 routesSupports MLD v1/v2 snooping.IPv6 protocolStatic IPv6 routesSupports MLD v1/v2 snooping.Multicast IGMP v1/v2/v3 snoopingPort-based rate limiting formulticast packets MVLANControllable multicastIGMP v1/v2/v3 snoopingPort-based rate limiting formulticast packetsMVLANControllable multicastIGMP v1/v2/v3 snoopingPort-based rate limiting formulticast packetsReliability S2700-SI: STP (IEEE 802.1d),RSTP (IEEE 802.1w)S2710-SI: STP (IEEE 802.1d),RSTP (IEEE 802.1w), MSTP(IEEE 802.1s) STP (IEEE 802.1d), RSTP (IEEE802.1w), MSTP (IEEE 802.1s),and RRPP topology and RRPPmulti-instanceSTP (IEEE 802.1d), RSTP (IEEE802.1w), MSTP (IEEE 802.1s),and RRPP topology and RRPPmulti-instanceSEP and ERPS (G.8032)Smart Link tree topology andSmart Link multi-instance,implementing millisecond-levelprotective switchoverTraffic sampling N/A N/A sFlowSecurity & Access features S2700-SI: Storm suppressionS2710-SI: Storm suppression, IPSource Guard802.1x authentication and limiton the number of users on aninterfaceStorm suppressionIP Source Guard802.1x authentication and limiton the number of users on aninterfaceStorm suppressionIP Source GuardS2700-SI: Multipleauthentication methods includingAAA, RADIUS, and TACACS+Port isolationSuppression of multicast,broadcast, and unknown unicastpacketsCPU defenseS2710-SI: Multipleauthentication methods includingAAA, RADIUS, and TACACS+Port isolationSuppression of multicast,broadcast, and unknown unicastpacketsCPU defenseDHCP snoopingMultiple authentication methodsincluding AAA authentication,RADIUS authentication, andTACACS+ authentication802.1x authentication, MACaddress authentication, MACbypass authenticationDHCP snoopingPort isolation and sticky MACPacket filtering based on MACaddressesSuppression of multicast,broadcast, and unknown unicastpacketsLimit on the number of learnedMAC addressesCPU defenseS2750-EI/S2720-EI: DHCP relayMultiple authentication methodsincluding AAA authentication,RADIUS authentication, andTACACS+ authentication802.1x authentication, MACaddress authentication, MACbypass authenticationDHCP snoopingPort isolation and sticky MACPacket filtering based on MACaddressesSuppression of multicast,broadcast, and unknown unicastpacketsLimit on the number of learnedMAC addressesCPU defenseS2750-EI/S2720-EI: DHCP relaySurge protection Surge protection capability ofservice ports: 7kV Surge protection capability ofservice ports: 7kVSurge protection capability ofservice ports: 7 kVManagement Stack (S2710-52P-SI-AC)Auto-ConfigCLI-based configurationRemote configuration usingTelnetSNMP V1/V2C/V3Remote network monitoringSSHv2Web-based device management Stack (S2700-52P-EI-AC,S2700-52P-PWR-EI)Auto-ConfigCLI-based configurationRemote configuration usingTelnetSNMP V1/V2C/V3Remote network monitoringSSHv2Web-based device managementStackEasy OperationCLI-based configurationRemote configuration usingTelnetSNMP V1/V2C/V3Remote network monitoringSSHv2Web-based device managementInteroperability NA NA Supports VBST (Compatible withPVST/PVST+/RPVST)Supports LNP (Similar to DTP)Supports VCMP (Similar to VTP)Operating environment ●Long-term operatingtemperature: –5°C to +50°C↵●Relative humidity: 10% to90% (non-condensing)●Long-term operatingtemperature: –5°C to +50°C↵●Relative humidity: 10% to90% (non-condensing)●Long-term operatingtemperature: –5°C to +50°C↵●Relative humidity: 10% to90% (non-condensing)Power AC:●Rated voltage range: 100 Vto 240 V AC, 50/60 Hz●Maximum voltage: 90 to 264V AC, 50/60 HzDC:●Rated voltage range: –48 Vto –60 V DC●Maximum voltage range: –36V to –72 V, DC AC:●Rated voltage range: 100 Vto 240 V AC, 50/60 Hz●Maximum voltage: 90 to 264V AC, 50/60 HzDC:●Rated voltage range: –48 Vto –60 V DC●Maximum voltage range: –36V to –72 V, DCAC:●Rated voltage range: 100 Vto 240 V AC, 50/60 Hz●Maximum voltage: 90 to 264V AC, 50/60 HzDC:●Rated voltage range: –48 Vto –60 V DC●Maximum voltage range: –36V to –72 V, DCDimensions (WxDxH) ●S2700-9TP-SI:250×180×43.6●S2700-18TP-SI/S2700-26TP-SI: 442×220×43.6●S2710-52P-SI:442×220×43.6●S2700-9TP-EI:250×180×43.6●S2700-9TP-PWR-EI:320×220×43.6●S2700-18TP-EI/S2700-26TP-EI: 442×220×43.6●S2700-26TP-PWR-EI:442×420×43.6●S2700-52P-EI:442×220×43.6●S2750-28TP-EI-AC/S2720-28TP-EI-AC: 442×220×43.6●S2750-20TP-PWR-EI-AC/S2750-28TP-PWR-EI-AC: 442×310×43.6Weight ●S2700-9TP-SI: <1.4 kg●S2700-18TP-SI: <2.4 kg●S2700-26TP-SI: <2.4 kg●S2710-52P-SI: <3 kg ●S2700-9TP-EI: <1.4 kg●S2700-9TP-PWR-EI: <2.5 kg●S2700-18TP-EI: <2.4 kg●S2700-26TP-EI: <2.4 kg●S2700-52P-EI: <3 kg●S2700-26TP-PWR-EI: <4 kg(without power supply)●S2750-20TP-PWR-EI: <4.5kg●S2750-28TP-EI: <3 kg●S2750-28TP-PWR-EI: <4.5kg●S2720-28TP-EI-AC: <3 kgPower consumption ●S2700-9TP-SI: <12.8 W●S2700-18TP-SI: <14.5 W●S2700-26TP-SI: <15.5 W●S2710-52P-SI: <38 W●S2700-9TP-EI: <12.8 W●S2700-9TP-PWR-EI: <154 W(PoE: 124 W)●S2700-18TP-EI: <14.5 W●S2700-26TP-EI: <15.5 W●S2700-52P-EI: <38 W●S2700-26TP-PWR-EI:<808W (PoE: 740 W)●S2750-20TP-PWR-EI: <435W (PoE: 370W)●S2750-28TP-EI: <15.7 W●S2750-28TP-PWR-EI: <445W (PoE: 370W)●S2720-28TP-EI-AC: <15.7WNetworking and Applications100 Mbit/s Access Rate for TerminalsThe S2700 can function as a desktop access device that provides an access rate of 100 Mbit/s for terminals and 1000 Mbit/s uplink interfaces to communicate with uplink devices.Ordering InformationItem Product Description1 S2700-9TP-EI-AC Mainframe (8 Ethernet 10/100 ports, 1 dual-purpose 10/100/1000 or SFP, AC 110/220V)2 S2700-9TP-EI-DC Mainframe (8 Ethernet 10/100 ports, 1 dual-purpose 10/100/1000 or SFP, DC -48V)3 S2700-9TP-SI-AC Mainframe (8 Ethernet 10/100 ports, 1 dual-purpose 10/100/1000 or SFP, AC 110/220V)4 S2700-18TP-EI-AC Mainframe (16 Ethernet 10/100 ports, 2 dual-purpose 10/100/1000 or SFP, AC 110/220V)5 S2700-18TP-SI-AC Mainframe (16 Ethernet 10/100 ports, 2 dual-purpose 10/100/1000 or SFP, AC 110/220V)6 S2700-26TP-EI-AC Mainframe (24 Ethernet 10/100 ports, 2 dual-purpose 10/100/1000 or SFP, AC 110/220V)7 S2700-26TP-SI-AC Mainframe (24 Ethernet 10/100 ports, 2 dual-purpose 10/100/1000 or SFP, AC 110/220V)8 S2700-52P-EI-AC Mainframe (48 Ethernet 10/100 ports, 4 Gig SFP, AC 110/220V)9 S2710-52P-SI-AC Mainframe (48 Ethernet 10/100 ports, 4 Gig SFP, AC 110/220V)10 S2700-9TP-PWR-EI Mainframe (8 Ethernet 10/100 ports, PoE+, 1 dual-purpose 10/100/1000 or SFP, AC110/220V)11 S2700-26TP-PWR-EI Mainframe (24 Ethernet 10/100 ports, 2 dual-purpose 10/100/1000 or SFP, PoE+, withoutpower module)12 S2700-52P-PWR-EI Mainframe (48 Ethernet 10/100 ports, 4 Gig SFP, PoE+, Dual Slots of Power, Including Single500W AC Power)13 S2750-20TP-PWR-EI-AC Mainframe (16 Ethernet 10/100 ports, 2 Gig SFP and 2 dual-purpose 10/100/1000 orSFP, PoE+, AC 110/220V)14S2750-28TP-EI-AC Mainframe (24 Ethernet 10/100 ports, 2 Gig SFP and 2 dual-purpose 10/100/1000 or SFP, AC 110/220V)15 S2750-28TP-PWR-EI-AC Mainframe (24 Ethernet 10/100 ports, 2 Gig SFP and 2 dual-purpose 10/100/1000 orSFP, PoE+, AC 110/220V)16 S2720-28TP-EI-AC Mainframe (24 Ethernet 10/100 ports, 2 Gig SFP and 2 dual-purpose 10/100/1000 or SFP, AC110/220V)17 500W PoE power supply unitMore InformationFor more information about Huawei Campus Switches, visit or contact us in the following ways:●Global service hotline: /en/service-hotline●Logging in to the Huawei Enterprise technical support website: /enterprise/●Sending an email to the customer service mailbox: ********************Copyright © Huawei Technologies Co., Ltd. 2018. All rights reserved.No part of this document may be reproduced or transmitted in any form or by any means without prior writtenconsent of Huawei Technologies Co., Ltd.Trademarks and Permissionsand other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.All other trademarks and trade names mentioned in this document are the property of their respective holders.NoticeThe purchased products, services and features are stipulated by the contract made between Huawei and thecustomer. All or part of the products, services and features described in this document may not be within thepurchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information, and recommendations in this document are provided "AS IS" without warranties, guarantees or representations of any kind, either express or implied.The information in this document is subject to change without notice. Every effort has been made in the preparation of this document to ensure accuracy of the contents, but all statements, information, and recommendations in this document do not constitute a warranty of any kind, express or implied. Huawei Technologies Co., Ltd. Address:Huawei Industrial Base Bantian, Longgang Shenzhen 518129 People's Republic of ChinaWebsite:。
QuidwayS2700系列企业网交换机的介绍
Quidway® S2700系列企业网交换机产品概述Quidway® S2700系列企业网交换机(以下简称S2700)是华为公司推出的新一代绿色节能的以太网智能百兆接入交换机。
它基于新一代交换技术和华为VRP®(Versatile Routing Platform)软件平台,针对企业客户的各种应用场景,提供简单便利的安装维护手段,同时融合了灵活的VLAN部署、完备的安全和QoS控制策略、绿色环保等先进技术,可满足以太网多业务承载和接入需要,助力企业用户搭建面向未来的IT网络。
S2700为盒式产品设备,机箱高度为1U,提供标准型(SI)和增强型(EI)两种产品版本。
包括S2700-9TP-EI、S2700-9TP-SI、S2700-18TP-EI、S2700-18TP-SI、S2700-26TP-EI、S2700-26TP-SI、S2700-52P-EI、S2700-9TP-PWR-EI、S2700-26TP-PWR-EI。
产品型号和外观Quidway® S2700系列包括以下交换机:S2700-9TPS2700-9TP-EI-AC S2700-9TP-SI-AC ●8个10/100Base-TX,1个千兆Combo口(10/100/1000Base-T或100/1000Base-X)●EI分交流供电和直流供电两种机型,SI只有交流机型S2700-9TP-PWR-EI ●8个10/100Base-TX,1个千兆Combo口(10/100/1000Base-T或100/1000Base-X)●交流供电●支持POE+S2700-18TPS2700-18TP-EI-AC S2700-18TP-SI-AC ●16个10/100Base-TX,2个千兆Combo口(10/100/1000Base-T或100/1000Base-X ),●交流供电S2700-26TPS2700-26TP-EI-AC S2700-26TP-SI-AC ●24个10/100Base-TX,2个千兆Combo 口(10/100/1000Base-T或100/1000Base-X)●EI分交流供电和直流供电两种机型,SI只有交流机型S2700-26TP-PWR-EI ●24个10/100Base-TX,2个千兆Combo 口(10/100/1000Base-T或100/1000Base-X)●交流供电●支持POE+S2700-52PS2700-52P-EI-AC ●48个10/100Base-TX,2个100/1000Base-XSFP,2个1000Base-X SFP,●交流供电产品特性和优势●免维护,易部署,易管理S2700支持自动配置,智能式即插即用,大大降低初始安装成本;采用全新交换ASIC技术,整机无风扇设计,减少机械故障点的同时免除凝露腐蚀和尘土侵害,能有效降低主机53%维护率。
华为 S2700系列交换机 产品彩页
华为 S2700系列交换机产品彩页2华为企业Sx700系列交换机S2700系列企业交换机产品型号和外观1华为企业Sx700系列交换机• 转发性能:17.7Mpps • 交换容量:32Gbps 2华为企业Sx700系列交换机简易运维Easy Operation• S2700支持华为Easy Operation 简易运维功能。
借助Easy Operation 简易运维功能可以实现简易安装、简易配置、简易监控和简易故障处理,大幅降低初始安装和配置成本;提高升级效率并降低工程成本;具备友好的人机界面和Web 网管,支持告警管理和可视化配置;支持故障设备更换免配置功能。
• S2700采用全新ASIC 交换芯片,支持无风扇设计,在减少机械故障点的同时免除凝露腐蚀和尘土侵害,能有效降低故障率。
灵活的业务控制能力• S2700-EI 支持丰富的ACL 策略控制,特别是支持基于VLAN 下发ACL 规则,实现VLAN 内多端口的灵活控制和统一资源调度。
• S2700支持多种VLAN 划分方式:支持基于端口、基于MAC 地址、基于协议、基于网段划分VLAN ,部署安全灵活,尤其适合有移动办公需求的网络场景。
• S2700支持GVRP ,可实现VLAN 的动态分发、注册和传播VLAN 属性,减少手工配置量、保证VLAN 配置正确性,减少因为配置不一致而导致的网络互通问题。
此外,还支持SSHv2、HWTACACS 、RMON 、基于端口的流量统计;支持NQA 网络质量分析,有利于网络规划和优化。
丰富的安全接入机制• S2700支持完备的DHCP Snooping 功能,通过侦听接入用户的MAC/IP 地址、租期、VLAN ID 、接口等信息,防止IP 报文伪造、中间人攻击、DHCP 服务器私接等常见网络安全威胁,保障网络接入安全。
产品特性和优势3华为企业Sx700系列交换机• S2700支持基于端口的源MAC地址学习限制功能,有效防止攻击者变换源MAC地址发动攻击而产生的泛洪。
华为综合实验-S2700交换机VLAN配置
DONGFANG COLLEGE,FUJIAN AGRICULTURE AND FORESTRY UNIVERSITY实验名称:华为综合实验-S2700交换机VLAN配置系别:计算机系年级专业:10级电子信息工程二班学号:1050302098姓名:曾喜德任课教师:林菡成绩:2012 年月日知识准备知识准备了解交换机的基本知识,了解交换机的基本原理,了解VLAN的原理。
阅读《Quidway S2700-SI 产品手册》。
实验目的掌握低端系列交换机产品VLAN的配置和使用实验内容VLAN业务的配置实验设备S2700 两台PC机四台直连网线 5条串口线(调测线) 一条实验拓扑交换机A和交换机B通过端口1相连,交换机A的端口2与交换机B的端口2是VLAN10 的成员,交换机A的端口3与交换机B的端口3是VLAN20的成员。
配置步骤交换机A的具体配置如下:[s2700] interface Ethernet 0/0/2[s2700-Ethernet0/0/2] port link-type access[s2700-Ethernet0/0/2] interface Ethernet 0/0/3[s2700-Ethernet0/0/3] port link-type access[s2700-Ethernet0/0/3]quit[S2700]vlan 10[S2700-vlan10]port Ethernet 0/0/2[S2700]vlan 20[S2700-vlan20]port Ethernet 0/0/3[S2700]interface Ethernet 0/0/1[S2700-Ethernet0/0/1]port link-type trunk[S2700-Ethernet0/0/1] port trunk allow-pass vlan 10 20[S2700-Ethernet0/0/1]quit交换机B的具体配置如下:[s2700] interface Ethernet 0/0/2[s2700-Ethernet0/0/2] port link-type access[s2700-Ethernet0/0/2] interface Ethernet 0/0/3[s2700-Ethernet0/0/3] port link-type access[s2700-Ethernet0/0/3]quit[S2700]vlan 10[S2700-vlan10]port Ethernet 0/0/2[S2700-vlan10]quit[S2700]vlan 20[S2700-vlan20]port Ethernet 0/0/3[S2700-vlan20]qu[S2700]interface Ethernet 0/0/1[S2700-Ethernet0/0/1]port link-type trunk[S2700-Ethernet0/0/1] port trunk allow-pass vlan 10 20[S2700-Ethernet0/0/1]quit验证方法PC-1和PC-3能互通PC-2和PC-4能互通PC-1和PC-4不能互通,PC-2和PC-3不能互通实验结论同一vlan下的设备可以互通,不同vlan下的设备不能互通;通过端口打TAG可以传递多个vlan信息。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
• 24个10/100Base-TX以太网端口,4个千兆SFP,2个复用的 10/100/1000Base-T以太网端口Combo
• 交流供电 • 转发性能:9.6Mpps • 交换容量:12.8Gbps
产品特性和优势
• 16个10/100Base-TX以太网端口,2个10/100/1000Base-T以太 网端口,2个复用的千兆Combo SFP
• 交流供电 • 转发性能:5.4Mpps • 交换容量:32Gbps
1
S2700-26TP-SI-AC S2700-26TP-EI-AC S2700-26TP-EI-DC
4
产品规格
项目
S2700-SI/S2710-SI*
S2700-EI
S2750-EI/S2751-EI/S2720-EI
下行端口
S2700-9TP-SI**/S2700-9TP-EI/S2700-9TP-PWR-EI:8个10/100Base-TX以太网端口 S2700-18TP-SI/S2700-18TP-EI/S2750-20TP-PWR-EI-AC:16个10/100Base-TX以太网端口 S2700-26TP-SI/S2700-26TP-EI/S2700-26TP-PWR-EI/S2750-28TP-EI-AC/S2750-28TP-PWREI-AC/S2751-28TP-PWR-EI-AC/ S2720-28TP-EI-AC:24个10/100Base-TX以太网端口 S2710-52P-SI/S2700-52P-EI:48个10/100Base-TX以太网端口
S2720-28TP-EI-AC
• 24个10/100Base-TX以太网端口,4个千兆SFP,2个复用的 千兆10/100/1000Base-T以太网端口Combo
• 交流供电,支持PoE+ • 转发性能:14.1Mpps • 交换容量:32Gbps
• 24个10/100Base-TX以太网端口,4个千兆SFP,2个复用的 千兆10/100/1000Base-T以太网端口Combo
• 交流供电,支持PoE+ • 转发性能:12.9Mpps • 交换容量:32Gbps
• 24个10/100Base-TX 以太网端口,4个千兆SFP,2个复用的 千兆10/100/1000Base-T以太网端口Combo
• 交流供电 • 转发性能:14.1Mpps • 交换容量:32Gbps
2
S2750-28TP-PWR-EI-AC S2751-28TP-PWR-EI-AC
• 24个10/100Base-TX以太网端口,2个10/100/1000Base-T以太 网端口,2个复用的千兆Combo SFP
• EI版本提供交流供电和直流供电两种机型,SI版本提供交流 机型
• 转发性能:6.6Mpps
• 交换容量:32Gbps
S2700-26TP-PWR-EI S2710-52P-SI-AC
上行端口
S2700-9TP-SI/S2700-9TP-EI/S2700-9TP-PWR-EI/:1个10/100/1000Base-T以太网端口,1 个复用的千兆Combo SFP
S2700-18TP-EI /S2700-18TP-SI /S2700-26TP-EI /S2700-26TP-EI /S2700-26TP-PWR-EI/ S2700-26TP-SI:2个10/100/1000Base-T以太网端口,2个复用的千兆Combo SFP
• 24个10/100Base-TX以太网端口2个10/100/1000Base-T以太网 端口,2个复用的千兆Combo SFP
• 交流供电,支持PoE+ • 转发性能:6.6Mpps • 交换容量:32Gbps
• 48个10/100Base-TX以太网端口,4个千兆SFP • 交流供电 • 转发性能:17.7Mpps • 交换容量:32Gbps
• S2700采用全新ASIC交换芯片,支持无风扇设计,在减少机械故障点的同时免除凝露腐蚀和尘土侵 害,能有效降低故障率。
灵活的业务控制能力
• S2700-EI支持丰富的ACL策略控制,特别是支持基于VLAN下发ACL规则,实现VLAN内多端口的灵活 控制和统一资源调度。
• S2700支持多种VLAN划分方式:支持基于端口、基于MAC地址、基于协议、基于网段划分VLAN, 部署安全灵活,尤其适合有移动办公需求的网络场景。
S2700系列企业交换机
S2700系列企业交换机
产品概述
S2700(包括S2710,S2720,S2750和S2751)系列企业交换机(以下简称S2700)是华为公司推 出的新一代绿色节能的智能百兆以太接入交换机。它基于新一代交换技术和华为VRP(Versatile Routing Platform)软件平台,能提供简单便利的安装维护手段,同时融合了灵活的网络部署、丰富 的QoS和安全控制策略、完备的高可靠机制、绿色环保等先进技术,可满足以太网多业务承载和接 入需要,助力企业用户搭建面向未来的IT网络。 S2700为盒式产品设备,机箱高度为1U,提供标准型(SI)和增强型(EI)两种产品版本。
S2710-52P-SI/S2700-52P-EI/:4个千兆SFP
S2750-20TP-PWR-EI /S2750-28TP-EI-AC/S2750-28TP-PWR-EI/S2751-28TP-PWR-EI/ S272028TP-EI-AC:4个千兆SFP,2个复用的千兆10/100/1000Base-T以太网端口Combo
• S2700支持GVRP,可实现VLAN的动态分发、注册和传播VLAN属性,减少手工配置量、保证VLAN 配置正确性,减少因为配置不一致而导致的网络互通问题。此外,还支持SSHv2、HWTACACS、 RMON、基于端口的流量统计;支持NQA网络质量分析,有利于网络规划和优化。
丰富的安全接入机制
• S2700支持完备的DHCP Snooping功能,通过侦听接入用户的MAC/IP 地址、租期、VLAN ID、接口 等信息,防止IP报文伪造、中间人攻击、DHCP服务器私接等常见网络安全威胁,保障网络接入安 全。
MAC地址表
支持8K MAC地址表; 支持删除动态MAC地址; 支持MAC地址老化时间可 配置; 支持黑洞MAC地址;
支持8K MAC地址表; 支持删除动态MAC地 址; 支持MAC地址老化时间 可配置; 支持基于端口的MAC 地 址学习使能控制; 支持黑洞MAC地址;
支持16K MAC地址表 支持删除动态MAC地址 支持MAC地址老化时间可配 置 支持基于端口的MAC 地址学 习使能控制 支持端口MAC地址数限制 支持黑洞MAC地址
• S2700支持基于端口的源MAC地址学习限制功能,有效防止攻击者变换源MAC地址发动攻击而产 生的泛洪。S2700支持ARP表限制学习功能,能防止ARP欺骗攻击将交换机ARP表项占满,保障合法 用户正常接入。支持IP Source Check 特性,防止非法IP地址仿冒带来的DOS攻击威胁。
3
• S2700支持集中式MAC地址认证和802.1x 认证功能,支持IP、MAC、VLAN、端口等用户标识元素 的动态或静态绑定,并支持用户策略(VLAN、ACL)的动态下发。
• 转发性能:2.7Mpps
• 交换容量:32Gbps
S2700-9TP-PWR-EI S2700-18TP-SI-AC S2700-18TP-EI-AC
• 8个10/100Base-TX以太网端口,1个10/100/1000Base-T以太 网端口,1个复用的千兆Combo SFP
• 交流供电,支持PoE+ • 转发性能:2.7Mpps • 交换容量:32Gbps
S2700-52P-EI-AC S2750-20TP-PWR-EI-AC
S2750-28TP-EI-AC
• 48个10/100Base-TX以太网端口,4个千兆SFP • 交流供电 • 转发性能:17.7Mpps • 交换容量:32Gbps
• 16个10/100Base-TX以太网端口,4个千兆SFP,2个复用的 千兆10/100/1000Base-T以太网端口Combo
简易运维Easy Operation
• S2700支持华为Easy Operation简易运维功能。借助Easy Operation简易运维功能可以实现简易安 装、简易配置、简易监控和简易故障处理,大幅降低初始安装和配置成本;提高升级效率并降低 工程成本;具备友好的人机界面和Web网管,支持告警管理和可视化配置;支持故障设备更换免 配置功能。
PoE特性 • S2700 PWR系列交换机,支持完善的PoE解决方案,用户可灵活配置PoE端口是否供电以及何时供
电。可以通过配置不同功率等级的PoE电源支持PoE(Power over Ethernet)功能,即可通过网线向 远端下挂设备(如IP Phone、WLAN AP、Security、Bluetooth AP等)提供-48V直流电源。作为供电 方PSE(Power Sourcing Equipment)设备,支持IEEE802.3af及802.3at (PoE+)供电标准,同时兼 容不符合802.3af及802.3at标准的PD(Powered Device)设备,并支持绿色PoE节电应用模式。其中 802.3at单端口供电功率高达30W,方便接入更大功率的终端。 丰富的高可靠机制 • S2700支持智能堆叠 iStack功能,能够将多台交换机通过堆叠虚拟化为一台逻辑设备来管理和使 用,实现多台设备的扩展。智能堆叠iStack提升交换容量、可靠性、扩展性,堆叠后的逻辑系统共 用一个IP地址,统一配置管理,大大降低系统运维的成本。 • S2700不仅支持传统的STP/RSTP/MSTP生成树协议,还支持SmartLink和RRPP(Rapid Ring Protection Protocol,快速环网保护协议)等增强型以太技术,可以实现毫秒级链路保护倒换,保证高可靠的 网络质量。 • S2700支持智能以太保护SEP(Smart Ethernet Protection),SEP是一种专用于以太链路层的环网协 议,提供毫秒级快速业务倒换性能,保证业务的不中断。SEP协议简单可靠、倒换性能高、维护方 便、拓扑灵活,可以大大方便用户进行网络的管理和规划。 • S2700支持G.8032(Ethernet Ring Protection Switching,简称ERPS)业界最新的环网标准协议,ERPS 标准基于传统的以太网MAC和网桥功能,利用以太网成熟的OAM功能和一个环网自动保护倒换 (Ring APS,简称R-APS)协议,实现以太环网的毫秒级快速保护倒换。ERPS支持多种业务,组网 模式灵活,为客户带来更低的OPEX和CAPEX。 完备的QoS策略 • S2700能基于VLAN、MAC地址、IP协议、源地址、目的地址、优先级、TCP或UDP端口号,实现复 杂流分类功能;支持基于流的限速功能,每个端口最大支持8个队列,支持WRR、SP、WRR+SP多 种队列调度算法,有效地保证高品质的语音、视频和数据等网络业务质量。 强大的防雷能力 • S2700采用内置防雷的专利技术,业务端口高达6KV的防雷能力,能有效抵御感应雷击的过电压。 在恶劣的应用环境下,甚至无法实现有效接地的场景,也可以大大降低设备的雷击损坏率。 绿色节能设计 • S2700功耗低,采用新一代高集成芯片和节能电路设计,均衡散热,支持空闲端口休眠;无风扇 静音设计,无噪音;辐射低,达到家用电器辐射标准,对人体无危害。