CSP 系列电机智能保护器说明书

合集下载

电机智能保护器配置手册说明书

电机智能保护器配置手册说明书

How to configure, monitor, and control Motor Insight via Modbus, DeviceNet, and PROFIBUSApplicationMotor Insight T is an advanced motor protective relay with thermal motor overload, supply,and load protection; configurable ground fault detection; power monitoring; an intuitive user interface; and optional communications. The optional communications allow for remote control and reset of faults, and remote monitoring of numerous operating and configuration parameters. The communication modules also include inputs that can be usedto bring the status of sensors or switches backto the system controller, as well as outputs to control the contactor or turn on pilot lights.OverviewThe industrial networks supported by the Motor Insight relay are all open networks. This means that there are many software tools already available that can be used to configure the device over these networks. Each of the supported networks will be discussed in this document, including suggestions for various configuration tools, many of which are free downloads from the Internet. In many cases, the network tools supplied by the manufacturerof the network master can be used to configure any device on that network.Overview of Modbus T, DeviceNet E and PROFIBUS TFor most applications, the Motor Insight relay parameters can be easily configured using its intuitive user interface. Then, the communication network master can be used to control and monitor the device during operation. This network master reads status information from each slave device and writes control information. The communication interface modules forMotor Insight allow control for the following:1. Remote reset of a fault2. Remote trip3. Control of on-board field outputs Numerous parameters are available to be monitored from Motor Insight, including:1. Device status bits2. rms current IA3. rms current IB4. rms current IC5. rms current average6. rms voltage VAB7. rms voltage VBC8. rms voltage VCA9. rms voltage average10. Total kW11. Voltage unbalance percent12. Current percent13. Apparent power factor14. Residual ground current deciamps15. Frequency16. Overload thermal pile17. Trip reason18. Overload status19. Error code20. Field inputsThe following is a discussion concerning the third-party software tools available for the open networks supported by Motor Insight. ModbusMotor Insight supports both Modbus RTU and Modbus ASCII modes, as well as baud rates from 9600 to 115.2K baud. It will communicate with any Modbus master.The unique aspect of Modbus is that special configuration tools are typically not necessaryas they are with many other industrial networks. The reason is that Modbus requires Modbus Data Register addresses for all parameters in all Modbus devices. This allows a Modbus master to easily read and write data to a Modbus slave device for configuration, control, and monitoring purposes. Motor Insight is no different. It has assigned a Modbus Data Address to all available parameters. This information is publishedin the Motor Insight overload and monitoring relays user manual, publication MN04209001E.Eaton Corporation Electrical Sector1111 Superior Ave. Cleveland, OH 44114United States877-ETN-CARE (877-386-2273) © 2010 Eaton CorporationAll Rights ReservedPrinted in USAPublication No. AP04209004E / Z9775 August 2010PowerChain Management is a registered trademark of Eaton Corporation.All other trademarks are property of their respective owners.Application Paper AP04209004E Effective August 2010How to configure, monitor, and control Motor Insight via Modbus, DeviceNet,and PROFIBUSIf a third-party Modbus software package is desired to configureor verify the configuration or operation of Motor Insight, there are numerous software tools available. Many of these tools are free downloads, such as ModScan. Others can be found by simply searching the Web for Modbus Software Tools.Eaton has a line of electronic operator interface devices called HM i.A program for a 4-inch HM i is available as a free download from /motorinsight or via this direct link. This program communicates via Modbus to multiple Motor Insight devices. It contains screens for configuring, monitoring, and controlling upto 16 Motor Insights from a single HM i. To obtain the HM i software needed to download the program to an HM i, visit / electrical. Then, click the “Tools & Downloads” link. Next, select “Software Downloads.” On the next page, under the Products drop-down, select “Operator Interface...” and then select “HM i Operator Interface Configuration Software.” Also note that the HM i software allows for changing the HM i program so it can be downloaded to any size HM i: 4-, 6-, 8-, or 10-inch unit.Another source of available Modbus tools can be found on the official Modbus Web site: .DeviceNetUnlike Modbus, where all parameters in a device have a data address assigned to them, DeviceNet slave devices use input and output assemblies. Each input assembly will include the same status bits indicating operational status of the device. The various input assemblies differ by the additional data that can be monitored with each. The Motor Insight relay has five different input assemblies. Two of these input assemblies allow the user to select the parameters to monitor. The various output assemblies are for control. They provide the ability to reset faults, trip the overload, and turn the outputs on-board the DeviceNet module on and off. DeviceNet is an open network that requires a software tool to configure slave devices and to map their data into the scan list of the master. The manufacturer of the DeviceNet master will provide a software tool to map slave devices into the scan list of the master so the system controller can control and monitor each Motor Insight. Motor Insight contains an intuitive user interface for configuration, but when on a DeviceNet network, it can be configured by any third-party DeviceNet commissioning tool as well. The DeviceNet specification requires that all DeviceNet products have an eds file (electronic data sheet). This file is a text file that is used to uniquely define each parameter in the device. DeviceNet commissioning tools are designed with the ability to import eds files for any valid DeviceNet slave device. The software tool can then be used to configure the device. There are two eds files and an icon file available for Motor Insight. They may be downloaded from/motorinsight. These files can then be imported into any valid DeviceNet commissioning software, such as:1. Eaton’s CHStudio E2. Eaton’s ELCSoft (DNET CONFIG Tool)3. Rockwell’s RSNetWorx E for DeviceNetCHStudio is a free download from the Eaton Web site; searchfor CHStudio and download the software and activation code.It can be used to configure any DeviceNet slave device, but notthe network master.ELCSoft is the programming software for the Eaton PLC line called ELC. This PLC line includes a complete DeviceNet master, the ELC-CODNETM module. The commissioning software is included in the ELCSoft programming software. It can configure any DeviceNet slave device by importing the eds file for the device and can fully configure the ELC-CODNETM DeviceNet master module.The manufacturer of the network master typically supplies the software tools needed to configure the master. RSNetWorxfor DeviceNet can be purchased from Rockwell or a Rockwell distributor. Motor Insight eds files can be imported into RSNetWorx for DeviceNet, allowing the software to configurethe Motor Insight and a Rockwell DeviceNet master.Once all slave devices on a DeviceNet network have been configured and mapped into the DeviceNet master’s scan list, the master will continuously poll the slave devices, like the Motor Insight, writing control data to them and monitoring various parameters. Motor Insight has more data available to monitor than any other overload relay of its type. This information is published in the Motor Insight overload and monitoring relay user manual, MN04209001E.Another source of available DeviceNet tools can be found on the official DeviceNet Web site: .PROFIBUSPROFIBUS is very similar to DeviceNet in that the network configuration tools are typically supplied by the manufacturer of the PROFIBUS master. There is also a file for PROFIBUS similar to the eds file for DeviceNet, called a GSD file. All valid PROFIBUS slave devices must have a GSD file. This file is imported into the PROFIBUS commissioning tool or the programming software, allowing the software to configure the device and map its I/O data so the PROFIBUS master can poll the slave devices for control and monitoring purposes. These PROFIBUS tools are supplied bythe manufacturer of the PROFIBUS master. The GSD file may be downloaded from /motorinsight. This file can then be imported into any valid PROFIBUS software tool, such as Siemen’s SIMATIC Software. Other PROFIBUS network product vendors are Woodhead Connectivity, Bihl+Wiedemann GmbH and PROCENTEC. Another source of available PROFIBUS tools can be found on the official PROFIBUS Trade Organization Web site: /.Supporting documentationMotor Insight User Manual MN04209001E Motor Insight DeviceNet Instructional Leaflet IL04209005EMotor Insight Modbus Instructional Leaflet IL04209004EMotor Insight PROFIBUS Instructional Leaflet IL0420900XEELC System Manual MN05003003EELC-CODNETM Instructional Leaflet IL05001003EHM i User manual MN04802014EAdditional helpIn the event that additional help is needed, please contact the Technical Resource Center at 1-877-ETN-CARE (386-2273).。

电机保护设备说明书.pdf_1719217409.6510355

电机保护设备说明书.pdf_1719217409.6510355

Certificates and Declarations (Document Number)
ABS Certificate ATEX Certificate BV Certificate
1SAA941001-0102 1SAA941001-3901 1SAA941001-0203
TF42-2.3
Minimum Order Quantity Customs Tariff Number
Popular Downloads
Data Sheet, Technical Information Data Sheet, Technical Information (Part 3) Instructions and Manuals
Environmental
Ambient Air Temperature
Ambient Air Temperature Compensation Maximum Operating Altitude Permissible Resistance to Shock acc. to IEC 60068-2-27 Resistance to Vibrations acc. to IEC 60068-2-6 RoHS Status
Standards
3
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² Flexible 1/2x 0.75 ... 1 mm² Flexible 1/2x 1 ... 2.5 mm² Rigid 1/2x 0.75 ... 4 mm²
Flexible with Ferrule 1/2x 0.75 ... 4 mm² Flexible with Insulated Ferrule 1/2x 0.75 ... 4 mm²

电动机保护器说明书

电动机保护器说明书

数显式电机保护器
一、功能简介:
1、反时限
2、手动(即时)/断电复位
3、可显示三相最大电流值
4、数字显示故障原因,便于处理故障
5、调节电流及时间旋钮时,可准确显示电流及时间设定值
6、过电流/堵转/缺相/不平衡/反相保护
7、显示部分与主体可分离,便于在面板上安装和操作
见附图2。

四、安装调试
1、将保护器固定在交流接触器旁,A1、A2接操作电源,主回路相线按R、S、T相序对
应穿过保护器的三相互感器,辅助触点接线端子95、96按接线图(附图3)连接。

2、调试方法
根据反时限特性和实际启动时间,保护设置时间=实际启动时间╳(110~120%)设
置后电机按所设特性脱扣,启动为冷态,启动后按照热态,具体参看说明书反时限脱扣特性曲线。

3、设置负载电流及过载延时
①调节“电流设定”旋钮,此时显示体上显示负载电流设定值,将负载电流设定
至电机额定电流的110%.
②调节“时间设定”旋钮,此时显示体上显示过载电流设定值,将过载延时设定
至电机启动所需的时间。

五、ZCDB-62工作过程中的显示状态(附图1)
三相最大电流值设定负载电流设定过载延时过电流
缺R相或R相电流低缺S相或S相电流低缺T相或T相电流低反相
六、ZCDB -62反时限特性曲线(附图2)
七、接线图(附图3)
热态 冷态 5S 10S 20S 30S 60S 5S 10S 20S 30S 60S 1000%。

电动机智能保护器说明书

电动机智能保护器说明书

0731-汤经理WDB-FST电动机智能保护器、AA说明书0731-汤经理AQ0OSENDIANQIWDB-FST智能电动机保护器⑧家质h【认证企业国索强制性认证(3C)及!£09^01:硬■誉踵傅乘认证电动机保护器订购热线:*************0731-汤经理一、概述我公司是一家从事于电动机保护器科研、生产、销售、技术支持的高新技术企业。

对电动机的保护有着深入的研究,本公司生产的电动机保护器具有低价、物美、品种齐全,性能卓越深受用户的喜爱。

电动机保护器从产品品种上分为四种。

1基本型,2基本智能型,3智能豪华型,4普通实用型。

本产品核心部件均采用美国MICRHIP公司新型十六位单片机及控制器配低功耗集成电路开发而成的,该保护器0731-汤经理具有保护功能齐全,测量参数直观,反应灵敏,动作及时可靠,工作稳定可靠、精度高、保护参数设定简单方便和数字化、智能化、网络化等特点,可满足不同层次用户的要求。

广泛应用于电力、石油、治金、化工、纺织等工业电动机及三相电力系统。

作过热、过载、欠载、断相、过压、欠压、堵转、三相电路不平衡保护。

还通过本机RS-485远程通迅接口和PC组成网络监控系统,通过PC对监控器保护参数进行修改及运行状态控制。

是一种提高电机运行安全和自动化管理水平的智能化仪器,可以与上位机通迅构成远程监控与一体的高新技术产品。

二、主要特点采用先进的微机技术与高性能的集成芯片,整机功能强大、性能优越。

测试精度高,线性度好,分辨率高,整机抗干扰能力强,保护动作可靠。

三相电流值,电压值及各类故障代号,显示于LED上、直观清晰。

稳定性好,长期工作无须维护。

采用E2PR0M存储技术,实现参数设定,掉电后设定参数仍保存下来,勿须再设定。

一机多用,可取代传统的电流互感器、电流表、电压表、热继电器和时间继电器等。

配有RS485串行数字接口,便于上位机(PC)进行数字通迅。

三、 依据电动机制造商的规范和过程控制要求设置预警和脱扣参数图1主要功能 保护功能:除了具有通用的保护功能外,还有自启动、通迅启动和关闭,且欠流、过压、欠压、三相电流不平衡、自启动等功能用户可取可舍。

智能数显电机综合保护器使用说明书

智能数显电机综合保护器使用说明书

智能数显电机综合保护器使用说明书(基本型)一:产品概述:JD-601ZS系列智能数显电机综合保护器是我公司在多年研制生产电控设备的基础上采用高可靠的工控芯片设计制造的通用电机测控装置。

该机功能强大、体积小巧、安装方便、工作稳定可靠、保护控制参数设定简单方便。

公司对产品拥有完全的自主知识产权,可根据用户设备的特点进行所有保护及控制特性的定制设计,并可省去普通电机启动控制柜中的电流表、电压表、电流电压互感器等元件,既提高了产品档次,也降低了生产成本。

该系列中漏电保护型、节能控制型、减压启动型等其他型号相关资料请致电本公司索取。

产品功能较多,请仔细阅读本说明,使用中有任何技术问题或特殊要求欢迎来电咨询。

二:常规保护特性:短路、堵转保护线路工作电流达到额定电流的8倍以上时延时0.5秒保护过载保护启动完成后根据反时限特性进行过载保护(备有0号至10号灵敏度逐次降低的10条保护曲线供选择,出厂默认2号曲线特性如下:1.2倍110秒,1.3倍65秒,1.4倍40秒,1.5倍30秒,1.8倍18秒,2倍12秒,2.8倍5秒,3.5倍3.5秒,5倍2秒,7倍1秒)过压保护电压高于设定值时延时2秒进行保护欠压保护电压低于设定值时延时5秒进行保护断相保护任何一相断相时延时1.5秒进行保护不平衡保护任何两相间电流相差50%以上时延时1.5秒进行保护三:新增保护及控制功能:自动躲启动电流自动检测电机启动状态,在启动过程中(启动时间用户可设定)过载保护灵敏度自动降低欠载保护工作电流低于设定值时延时5秒进行保护带电容运行在有就地电容补偿的情况下自动适应非故障的三相不平衡故障记忆自锁故障保护后记忆自锁,显示故障数据和状态等待人工消除。

断电后不丢失数据,上电后自动保持故障保护状态,接点不闭合,不会带故障运行。

电流电压显示可单显或轮显三相电流、平均电流、电源电压。

四:细节说明:4.1、带电容运行情况下实际电流不是电机自身电流,空载时线路电流远小于电机空载电流,轻度不平衡就会导致缺相或不平衡保护,系统对这种情况可以进行屏蔽。

CSP1000系列使用说明书

CSP1000系列使用说明书

断 路 器 状 态
+24
V 输 出
合闸 出口
跳闸 出口
跳闸 信号
告警 AC/ AC/ GN 信号 DC+ DC- D
通讯
开关量输入源
B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11
1、CSP1000S后端子说明 ................................... - 6 2、CSP1000T后端子说明 ................................... - 6 3、CSP1000M后端子说明 ................................... - 7 4、CSP1000C后端子说明 ................................... - 7 七、CSP1000 系列装置显示及按键操作: .............................. - 8 1、面板指示灯说明(以CSP1000T为例) ...................... - 8 2、键盘说明 ............................................ - 8 3、人机接口 ............................................ - 9 八、CSP1000 系列装置操作与说明 ................................... - 13 1、CSP1000S微机线路保护装置 ............................ - 13 2、CSP1000T微机变压器保护装置........................... - 14 3、CSP1000M微机电动机保护装置........................... - 15 4、CSP1000C微机电容器保护装置........................... - 17 九、运输与贮藏 ................................................... - 18 十、售后服务 ..................................................... - 18 -

电机保护设备说明书.pdf_1719234974.3339334

电机保护设备说明书.pdf_1719234974.3339334
Rated Operational Current DC-13 (Ie)
Degree of Protection Pollution Degree Connecting Capacity Auxiliary Circuit
Connecting Capacity
2
1SAZ700404F0001
45 mm 76.7 mm 53.5 mm
PThermal Overload Relay
General Information
Extended Product Type Product ID EAN Catalog Description
Long Description
Ordering
Certificates and Declarations (Document Number)
ABS Certificate
1SAA941001-0102
T16-0.74
BV Certificate CB Certificate CQC Certificate cUL Certificate Declaration of Conformity - CCC Declaration of Conformity - CE DNV GL Certificate EAC Certificate Environmental Information GL Certificate GOST Certificate Instructions and Manuals LR Certificate RINA Certificate RMRS Certificate RoHS Information Time-Current Characteristic Curve UL Certificate

智能电动机保护器使用说明书

智能电动机保护器使用说明书
1
5.7 250A 电流互感器外形尺寸..................................................................................................................................................12 5.7 800A 外置电流互感器外形尺寸..........................................................................................................................................13 5.8 漏电流互感器外形尺寸.......................................................................................................................................................13 5.9 显示模块外形尺寸...............................................................................................................................................................14 6 操作指南....................................................................................................................................................................................... 15 6.1 90L 显示模块面板................................................................................................................................................................15 6.2 显示操作说明........................................................................................................................................................................ 15 6.3 面板设置信息及菜单概述...................................................................................................................................................16 7 保护功能.....................................................................................................................................................................................24 7.1 过载保护................................................................................................................................................................................ 24 7.2 断相/不平衡保护.................................................................................................................................................................. 25 7.3 剩余电流保护(接地/漏电).............................................................................................................................................. 25 7.4 堵转保护................................................................................................................................................................................ 25 7.5 阻塞保护................................................................................................................................................................................ 25 7.6 欠载(欠流)保护...............................................................................................................................................................26 7.7 起动超时保护........................................................................................................................................................................ 26 7.8 欠压保护...............................................................................................................................................................................26 7.9 过压保护...............................................................................................................................................................................26 7.10 7.11 7.12 7.13 7.14 8 欠功率保护.........................................................................................................................................................................26 相序保护.............................................................................................................................................................................26 外部故障保护.....................................................................................................................................................................26 温度保护.............................................................................................................................................................................26

JD (S) 系列智能型电动机保护器 说明书

JD (S) 系列智能型电动机保护器 说明书

ISO9001 质 量 体 系 认 证 企 业J D(S) 系列智能型电动机保护器使用说明书一、概述本系列电动机智能型保护器(以下简称保护器)适用于交流50Hz,额定工作电压380V及以下的供电电路中与交流接触器等开关电器组成电动机控制电路。

当电动机的主电路出现断相、过载、堵转、漏电等非正常工作状态时,及时断开开关电器触头,分断电动机的三相电源,快速可靠地保护电动机。

保护器采用电位器量化整定方式,直接根据电机铭牌标定的额定电流值整定保护器电流,具有准确、直观、方便的优点,取代了原保护器整定无量化,需启动电机整定,而这种整定方式不能准确整定到电机的额定电流。

保护器采用过电流倍率控制下的智能多区段反时限保护技术,使过载保护功能更加合理,有效避免轻过载区的误动作,保证重过载区和短路故障的快速保护。

保护器采用电流倍率控制下起动过程中延时避让技术,当电动机在正常起动电流倍率范围内起动时,起动避让时间有效;当电机起动电流倍率超出正常起动电流倍率范围或断相时,起动避让时间无效,电机将得到快速保护。

二、主要技术数据三、接线图四、外形及安装尺寸图8765432191011JD-501S JD-601S工作电源零线漏电信号JD-501SJD-601S型号参数JD-501S JD-601S额定整定电流或额定功率范围过载动作时间启动避让时间断相动作时间堵转动作时间复位方式触点容量显示方式机械寿命电寿命安装方式额定电压AC380V 50Hz (其它电压等级可订做)2~50A80~200A20~100A25s5s~35s可调1.5倍过载保护时间≤100s并具有凡时限特性≤6s≤6s面板按钮复位或断电复位5A 380V(阻性)LED发光管指示1×106次装置式1×105次A、参照应用电路举例将保护器与控制线路正确相连(保护器固定在交流接触器下方为宜,且三相电流线分别同向穿B、通电试验:接通保护器电源,运行(绿色)指示灯亮,将整定测量开关设定在整定位置上,观察保护器电流显示,调节整定电位器电位器顺时针旋转至电机铭牌上的额定电流值。

电动机保护器说明书

电动机保护器说明书

电动机保护器说明书1.概述微机监控电机保护器适用于AC380V、AC660V低压系统,作为低压异步电动机和增安型电动机的保护、监测和控制的新一代智能化综合装置。

除了先进的电动机保护、监控功能,还提供了设备运行和跳闸的记录以及额定参数等重要信息,并且采用现场总线方式结构,为现代化的设备管理带来很大的便利;广泛用于石油、化工、电力、冶金、煤炭、轻工、纺织等行业。

符合标准:GB3836.3-2000、GB14048.4-2003、IEC2552.特点●“tE时间保护”符合有关增安型防爆电动机过载保护的国家标准(GB3836.3-2000)●交流采样,测量A、B、C三相电流及控制回路电压●现场显示电动机运行状态,保存三次电动机故障跳闸记录●一路保护输出,一路自定义继电器输出,一路4~20mA电流输出或RS485接口●高清晰度宽温液晶显示,并具有背景光,跟随电动机运行状态和用户要求实时显示●三相电流不平衡、断相、过压、欠压、自启动等功能用户可取可舍●采用E2PROM存储技术,实现参数电设定,掉电后设定参数仍保存下来,勿须再设定●采用RS485通信总线,可广泛用于各种监控系统作为带有电机保护及控制的智能化监控单元●一机多用,可取代电流表、电压表、热继电器、电流互感器、时间继电器和漏电继电器等3.主要功能保护功能:过流、堵转、断相、三相电流不平衡、过压、欠压、短路、漏电(选配)等故障保护测量功能:三相电流、控制回路电压的测量和显示通用功能:增安型电动机保护、三相异步电动机保护、馈线保护,三种保护装置通用通信功能:通过本保护器的RS485接口与上层系统通信。

总线接口支持参数设置、控制及监测等功能,支持Modbus通信协议。

一般采用RS485总线接口进行物理连接,通常上位机或PLC设备作为主站,本保护器作为子站。

电流输出:4~20mA电流输出,20mA对应的电流值可设。

4.型号说明微机电动机保护监控装置适用于AC660V及以下低压系统,作为低压电动机馈线终端的保护、监测和控制的新一代智能化综合装置。

电机保护器说明书

电机保护器说明书

EOCR-3DD3DD与外接CT配合时的尺寸图示特点:•内装MCU(MCU)•三只完整的电流互感器•多种保护功能•数字电流表功能•脱扣(动作)原因显示•人工现场复位•电子遥控复位•自检功能•预报警设置功能•适应各种现场环境•电机起动延时(D-TIME),脱扣延时(O-TIME)可独立连续设定。

•失电安全自保(NO VOLT RELEASE)下载使用说明书:EOCR-3DD前调整面板图示:前面板DIP开关组(SW1-SW4):开关编号功能“OFF”关“ON”开SW1安全保护失效有效SW2逆相保护不能进行电机反转保护可以进行电机反转保护SW3动作特性定时限反时限SW4报警见相关介绍保护类型:可保护项目脱扣时间过电流O-TIME缺相4秒(05:1A,60:5A以上时动作)堵转D-TIME反相0.1秒(SW2拨至RPR位置)相间不平衡8秒故障显示:功能(项目)LED显示脱扣原因脱扣延时时间简单描述过电流A相出现5.5A的电流定时限:经过OT设置的时间后。

反时限:按时间--电流特性曲线动作。

负载电流大于预先设定的保护电流值。

逆相相序改变引起电机反转0.1秒内动作SW2置“ON”位缺相B相缺相4秒内动作相不平衡A相出现最小的不平衡电流2.1A8秒[((最大电流-最小相电流)÷最大相电流)]×100%>50%堵转C相出现最大的堵转电流9.5A经过DT设置的时间立即动作(仅用于定时限方式)负载电流大于预先设定的保护电流值的300%时。

报警输出:报警LED显示原因描述顺时针缓缓旋转报警点设置旋钮,显示窗显示“A”闪动,数字“85”,含义是:电机即时负载电流达到继电器预先设置保护电流值的85%。

报警设置值的范围是:50-100%或者关闭报警输出功能,当电机的(即时负载电流÷预先设置保护电流电流)×100>报警设置值时,显示窗显示“A”闪动,并从报警输出继电器(07,08)送出通-断信号。

ABB软启动器PSS说明#精选.

ABB软启动器PSS说明#精选.

ABB软启动器的型号、选用说明以及功能一、三大系列。

普通型PSS智能型(带微处理器,不带内置旁路接触器)PST智能型(带微处理器,带内置旁路接触器)PSTB二、两种电压规格软启动器主回路电压,以PSS型为例,样本上红色标记的,主回路230-500V,对应的型号是-500系列;主回路400-690V,对应的型号是-690V系列。

通常我们国家的工业电压是380V,所以应该选-500系列。

-690V贵很多。

电机额定电压,有400V,500V,690V三种规格,通常我们国家是400V三、平时我们经常说额定功率,其实实际上是用额定电流来选型,样本上列出的是标准电机额定功率对应的额定电流。

四、内接还是外接内接可以降低一个容量来选用软启动器,或说可以启动高一个容量的电机。

以PSS18/30-500的软启动器为例,外接是18A的额定电流,对应的是7.5W的标准电机;内接是30A的额定电流,对应的是15W的标准电机。

五、软启动器的功能为了适应现代化生产,为减少对电网的冲击。

对机械的磨损。

减少对启动装置的维护。

可调启动电流。

可校调启动转矩。

可软停车的软启动器被广泛应用于鼠龙型电动机的启动,现以ABB公司软启动器为例:详细介绍其功能及特性。

ABB公司软启动器有以下规格型号:PSS03—25—500L两相控制适用于小型电机的紧凑设计。

这种小型软启动器具有内置的旁路触点。

可长期带负载运行。

PSSI8/30一PSS142/245适用于普通性负载。

同一装置可用“外接”和“内接”两种连接方法(图二)。

采用内接可减少42%流经软启动器的电流。

也就说使用户有可能用58A的软启动器来控制和运行IOOA的电机。

限流功能为可选件。

因此其启动特性有两种设定:1)无限定启动电流时:可设定启动时间(O一3os),启动电压(3O%一70%Ue)其起动曲线见图三。

2)有限定启动电流:需外接数个电流互感器(变化为/1),可设定启动时间,启动电流倍数。

SPAC202M 马达保护器使用说明书

SPAC202M 马达保护器使用说明书
7 端子排图 .................................................................................................................22
8 安装环境与结构 ......................................................................................................24
目录
1 产品简介 ...................................................................................................................1
2 功能特点 ...................................................................................................................1
上传和下发; z 第八、九路开关量可编程定义其功能。 z 9 种电流保护,3 种电压保护,保护范围动作时间均可自由设定。 z 拥有两级保护的执行能力。 z 系统参数可以通过面板按键或上位机通讯设置,并具有两级密码管理权限; z 所有关键数据(系统参数等)在失电情况下可保存十年以上; z 完善的事故记录及自检功能,友好的人机界面。

精确测量范围 20~500V 0.1~2In 40~70Hz
精度(可选) 1.0% 1.0% 0.5% 3.0% 1.0% 4.0%
额定值 100V、380V、
660V 1A/5A
50Hz

AMDSH-X F00□ 系列电动机保护器使用说明说明书

AMDSH-X F00□ 系列电动机保护器使用说明说明书

AMDSH-X/F00□ 系列电动机保护器使用说明产品概述主要特点:DSP 为核心,数字设定,数字显示,保护功能完备、保护性能可靠,检测电压,通用电流互感器检测电流。

保护功能:缺相、短路、接地、堵转、过载、电流不平衡。

适用范围:额定电压不高于1140V,50Hz或60Hz,起动负载重、起动时间长的三相交流电动机。

电流互感器一次电流(A)100 150 200300400500600800 1000 12001600最大设定电流(A) 65 98 130195260325390520 650 7801040最小设定电流(A) 20 30 40 60 80 100120160 200 240320电动机最大功率(KW) 30 45 55 90 132160185250 315 355500电动机最小功率(KW) 11 15 22 30 45 55 75 90 110 132160工作电压:AC 85V — 265V(工作电源也是检测的电压信号)功率消耗:小于 2W检测电压:AC 0—300V(检测工作电源电压,显示值可由参数设为检测值的1、1.732、3、5.196倍。

)采集精度:0.5环境温度:- 20℃ — 50℃继电器触点:AMDSH-X/F001:1组常开、常闭触点,AC 220V/10A(阻性负载)、DC 30V/10A;AMDSH-X/F002:2组常开、常闭触点,AC 220V/5A(阻性负载)、DC 30V/5A;AMDSH-X/F00□系列电动机保护器数据显示AMDSH-X/F00□ 系列电动机保护器在电动机正常运行时,显示电动机A、B、C相电流、电压;当电动机发生缺相、短路、接地、堵转、过载、电流不平衡故障时,断开内部继电器触点停止电动机运行(故障灯亮),同时显示故障代码指示故障类型,并且显示电动机发生故障时的A、B、C相电流、电压值。

AMDSH-X/F00□ 系列电动机保护器主单元LED 数码管显示区LED 数码管显示区有5位LED数码管,显示电动机的三相电流、电压、故障代码及电动机保护器参数。

电动机保护器的使用说明

电动机保护器的使用说明

电动机保护器的使用说明
一、电动机保护器的功能
1.无故障运行:电动机保护器可以监测电机的运行状态,并可以自动检测电机是否正常工作,如果出现故障,及时发出警报,确保该电机正常运行。

2.保护运行:电动机保护器可以实时检测电机的运行状态,如果电机出现异常,则及时发出警报,保护电机免受损坏,确保电机正常运行。

3.能源节约:电动机保护器可以通过监测来实现节能减排,即节约电能,减少电力耗用,降低电费开支,从而达到节能减排的目的。

二、电动机保护器的安装
1.确定安装位置:在安装电动机保护器之前,首先应考虑电动机保护器的安装位置,它应该安装在电动机的附近,以减少运行中受到的干扰,同时可以较好的保护电机。

2.连接电缆:在安装电动机保护器之前,需要将电缆和电动机连接起来,安装时应当按照正确标准,保证电缆连接的牢固程度,以确保电动机保护器的正常工作。

CSP2000系列技术说明书上册(第四版)

CSP2000系列技术说明书上册(第四版)

第一章 CSP2000系列微机保护概述1.概述CSP2000系列微机保护及自动装置是为了适应电力系统各发电厂、变电站、配电站及工厂大型用电设备等对继电保护的新要求,把各用户对我公司继电保护提出的宝贵建议,结合多年总结的经验在原有继电保护的基础上成功地推出的第三代新产品,为35KV及以下电压等级架空线路、电缆线路、变压器、电动机、电容器、PT柜等一次设备提供完善的保护控制功能。

CSP2000系列微机保护及自动装置由高集成度、总线不出芯片单片机、高精度电流电压互感器、高绝缘强度出口中间继电器、高可靠开关电源模块等部件组成。

具有集成度高、保护配置齐全、抗干扰能力强、功耗小、抗恶劣环境等优点,在CSP1000系列基础上增加到五路CT采样,三路PT采样,大大地提高了保护装置的可靠性和灵敏性。

五路开入量,七路信号输出口,四路保护输出口的设计,使保护装置功能更加齐全。

外观尺寸经过精心设计,小巧精致,能够直接安装在环网开关柜上,也可集中组屏安装。

CSP2000系列微机保护及自动装置具有以下特点:➢采用最新型高集成度单片机开发平台,总线不出芯片,抗干扰性能好。

➢采用统一的硬件框架、软件平台,产品一致性好。

➢装置采用全密封铝合金结构,抗电磁干扰能力强,外形美观精致,安装十分简易。

➢保护功能配置灵活齐全,各种保护功能均可以通过控制投退设定。

➢模拟量输入、开关量输入、电源输入及通讯接口部分采用了变压器隔离、光电隔离、TVS 保护的抗干扰措施,使得装置的抗干扰能力特别强。

➢装置具备完善的自检功能,当发现装置工作不正常时可靠闭锁保护出口,保证装置不会误动。

➢采用专用时钟芯片,由单独的晶振支持,带有备用电池,时钟即使在装置掉电后也能正确走时,大容量的存储器使装置能准确记录一百个各种故障信息。

➢装置具有三级看门狗,外部硬件看门狗、CPU硬件定时器看门狗和软件看门狗,使装置在任何情况下不会死机。

➢具有高速光电隔离RS485通讯接口,通讯稳定可靠,并向用户提供开放的通讯协议,方便实现综合自动化。

电机保护设备说明书.pdf_1719215379.3695738

电机保护设备说明书.pdf_1719215379.3695738

Certificates and Declarations (Document Number)
ABS Certificate
1SAA941001-0102
T16-1.0
BV Certificate CB Certificate CQC Certificate cUL Certificate Declaration of Conformity - CCC Declaration of Conformity - CE DNV GL Certificate EAC Certificate Environmental Information GL Certificate GOST Certificate Instructions and Manuals LR Certificate RINA Certificate RMRS Certificate RoHS Information Time-Current Characteristic Curve UL Certificate
Connecting Capacity Main Circuit UL/CSA Connecting Capacity Auxiliary Circuit UL/CSA Tightening Torque UL/CSA
Main Circuit 600 V AC
1A (NC:) B600 (NC:) Q600 (NO:) Q600 (NO:) D300 Flexible 1/2x 18-12 AWG Stranded 1/2x 18-10 AWG Flexible 1/2x 18-12 AWG Stranded 1/2x 18-12 AWG Auxiliary Circuit 9 ... 11 in·lb Main Circuit 9 ... 13 in·lb

CSP2000-B系列微机保护技术说明书

CSP2000-B系列微机保护技术说明书
四、选型指南
1、CSP2000-B系列型号说明
2、CSP2000-B系列微机保护装置选型列表
产品名称
功能介绍
型号
微机线路保护装置
三段式相间过流保护及后加速功能、反时限过流保护、过负荷保护、低电压保护、过电压保护、定时限零序过流保护、反时限零序过流保护、三相一次重合闸、PT断线告警、跳闸回路断线告警、防跳功能、故障闭锁合闸回路功能、失压闭锁合闸回路功能、100条故障事故记录、大屏幕液晶、中文汉字显示、RS485通讯接口
允许偏差±20%,纹波系数不大于5%
交流电流:额定5A或1A(订货注明)
交流电压:100V(线电压)
额定频率:50Hz
功率消耗:直流回路<8W
交流回路<0.5VA/相(In=1A)
<1VA/相(In=5A)
交流电压回路<0.5VA/相(在额定电压下)
精确测量范围:相电流0.1In–20In
零序电流0.1A–10A
①开关处于合位
2无闭锁重合闸信号
9.3闭锁重合闸条件
下面任一条件满足,闭锁重合闸:
1过负荷动作
2低电压动作
3过电压动作
4有闭锁重合闸开入信号(包括手动分闸、遥控分闸及其它外部闭锁条件)
注:合闸出口500ms后返回。
10、跳闸回路断线告警
本装置可监视断路器的控制回路,不需要再外接任何监测回路,在开关处于合闸状态下跳闸回路发断线时,装置会准确判断出并延时3秒后发出告警信号,同时在显示屏上显示故障信息,通知运行人员及时进行处理。此功能可通过控制投退设定进行设定。
CSP2000T-B
基本型+电压保护
除具有基本型功能以外,还具有低电压和过电压保护功能
CSP2000T/V-B

简易电机智能保护控制器说明书

简易电机智能保护控制器说明书

电机智能保护控制器说明书一、控制接线图表1 QQ1245246431.三相电机输入接线端子。

2.三相电机输出接线端子。

3.运行停止及故障指示灯。

4.拨动开关,三档分别为:手动,停机,自动。

5.额定电流通过电位器进行设定。

6.控制信号输入端子。

从左往右分别为:电源(+12V), 地(GND),运行控制信号,故障反馈信号。

二、功能说明1、保护器共三种运行状态:手动、停止、自动;手动状态:在没有故障时,手动状态将使电机运行,反馈输出0V;有故障时,将延时5秒自动停止电机运行,反馈输出12V,故障灯闪烁直到复位。

自动状态:没有故障,且控制电机运行的信号为启动时,保护器将启动,反馈输出0V;有故障,或者电机运行信号为停止时,有故障,保护器延时5秒停止电机运行,反馈输出12V。

停止状态:停止状态时保护器将停止电机运行,反馈输出0V,如果保护器在手动或自动运行时有故障出现,可以通过将拨动开关打到停止档来复位保护器的故障。

2、保护器的故障类型分为三种:过流、欠流、开路。

当有故障时保护器自动延时停止运行,并输出一路12V故障信号。

过流:过流主要保护电机的过载、缺相启动(缺相启动时电机堵转,电流都比较大,一般至少在2-3倍额定电流以上)以及双向可控硅损坏时的报错故障显示(可控硅损坏后,在停止状态下也可能会有电流,此时报过流)。

欠流:当运行时,出现缺相(轻载为欠流)电流大于0A且小于设定值的50%时,保护器将报欠流。

开路:当运行时,出现开路时,电流等于0A(实际设定为接近0A),保护器报开路。

3、保护器的复位:出现故障后需将拨动开关拨到停止档为复位。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
八、型号规格.......................................................................................4
九、注意事项.......................................................................................4
4)环境温度:-20℃~+55℃,相对湿度:≤90%,无腐蚀气体、无剧烈振动、冲
击的场所。
四、主要功能
1)具有过流、堵转、三相不平衡、断相、过电压、欠电压、短路,动作准确可
靠。
2)显示内容:正常状态时,显示运行电流;故障时显示故障状态。
3)设定参数:额定电流,过电压、欠电压、电机起动时间、过电流反时限序号。
四、主要功能.......................................................................................1
五、外型尺寸.......................................................................................2
二、主要特点.......................................................................................1
三、正常使用条件...............................................................................1
电机智能保护器使用说明书
一、概述
电机智能保护器采用先进的集成电路及微机技术,具有保护功能强,性能可
靠,操作方便,且便于安装维护等优点。
二、主要特点
1)各类故障以不同的字符提示,显示直观清晰,并具有过流、过压、欠压保护,
故障数据记忆显示,有关保护设定均以字符和数字显示,准确方便。
2)测量精度高,线性度好,分辨率高;整机抗干扰能力强,保护动作可靠。
CSP系列电机智能保护器



(V2.0)
杭州华光电气有限公司
HANGZHOUCHINA-SHINEELECTRICCO.,LTD
一、概述................................................................................................1
-1-
电机智能保护器使用说明书
五、外型尺寸
ห้องสมุดไป่ตู้8.5
109
六、主要技术指标...............................................................................2
七、操作方法.......................................................................................3
3)一机多用,可取代传统的电流表、电压表、热继电器和时间继电器等,并具
有软件自诊断功能。
4)仪表可选择带DC4-20mA的模拟量信号输出功能,方便与自控系统联网。
三、正常使用条件
1)适用于主回路:AC380V。
2)工作电源电压:AC220V。
3)监控器输出接点容量:AC220V5A、AC380V3A。
十、订货说明.......................................................................................4