水位报警器电路图
报警器警示器应用电路图

报警器、警示器应用电路图本文从EEPW电路图中为您整理了水位告警器、用LM431做的延时开关、简易水位(液位)告知装置‐、过压自动断电装置制作、医用输液报警器这5款报警器、警示器应用电路图。
具体详情见下:一.水位告警器Water level alarmThis circuit not only indicates the amount of water present in the overhead tank but alsogives an alarm when the tank is full.The circuit uses the widely available CD4066, bilateral switch CMOS IC to indicate the water level through LEDs.When the water is empty the wires in the tank are open circuited and the 180K resistors pulls the switch low hence opening the switch and LEDs are OFF. As the water starts filling up, first the wire in the tank connected to S1 and the + supply are shorted by water. This closes the switch S1 and turns the LED1 ON. As the water continues to fill the tank, the LEDs2 , 3 and 4 light up gradually.The no. of levels of indication can be increased to 8 if 2 CD4066 ICs are used in a similar fashion.When the water is full, the base of the transistor BC148 is pulled high by the water and this saturates the transistor, turning the buzzer ON. The SPST switch has to be opened to turn the buzzer OFF.Remember to turn the switch ON while pumping water otherwise the buzzer will not sound!二.用LM431做的延时开关Make the delay switch with LM431一般延时开关电路多用NE555来做,但是其最高工作电压只能达到18伏,有客户要求能工作在24伏的延时开关电路,用于汽车延时点火。
水位报警器原理图和程序完整版

设计功能
当水位在低水位以下时,相应电路导通, 红色发光二极管亮,报警器报警,电泵抽 水 当水位在低、中水位之间时,报警停止, 红灯灭,绿灯亮,电泵继续工作 直到水位到达高水位时,绿灯灭,黄灯亮, 报警器报警,电泵停止打水
电路图
程序
ORG 0000H LJMP MAIN ORG 0030H DDB BIT P2.0 DYB BIT P2.1 ZB BIT P2.2 GDB BIT P2.3 GYB BIT P2.4 JD1 BIT P2.5 JD2 BIT P2.6
焊接一块这样功能强大的电路板多少钱呢 总共15.3元。
谢谢观赏!
MAIN:
DX: CLR DDB CLR DYB SETB JD1 CLR JD2 ;低位一下的程序功能 红灯亮、LS3响、打水 SETB ZB LCALL DELAY JNB P1.0,DX1 LJMP DX SETB DDB SETB DYB RET
DX1:
ZD: CLR ZB RET ;中低位之间的程序功能 绿灯亮
ORL P1,#07H MOV A,P1 CPL A ANL A, #07H CJNE A,#00H,LOOP2 LJMP DX LOOP2: CJNE A,#01H,LOOP3 LJMP ZD LOOP3: CJNE A,#03H,LOOP4 LJMP ZG LOOP4: CJNE A,#07H,LOOP5 LJMP GS LOOP5: LJMP MAIN
高位报警
R8
220
正常水位
R6
220
低位报警 R1
220
R7
750
Q4
NPN
R5
750
Q6
NPN
U1
19 XTAL1 P0.0/AD0 P0.1/AD1 P0.2/AD2 P0.3/AD3 P0.4/AD4 P0.5/AD5 P0.6/AD6 P0.7/AD7 P2.0/A8 P2.1/A9 P2.2/A10 P2.3/A11 P2.4/A12 P2.5/A13 P2.6/A14 P2.7/A15 P3.0/RXD P3.1/TXD P3.2/INT0 P3.3/INT1 P3.4/T0 P3.5/T1 P3.6/WR P3.7/RD 39 38 37 36 35 34 33 32 21 22 23 24 25 26 27 28 10 11 12 13 14 15 16 17 DDB DYB ZB GDB GYB JD1 JD2
全自动水位控制器_水泵全自动液位控制器_DF-96C_380V_20A

DF-96系列全自动水位控制器工作原理一、整机工作原理该型全自动水位控制器电路原理如下图所示。
由图可知,本控制器电路主要由电源电路、水位信号检测电路、输出驱动电路三部分组成,下面分别加以介绍。
1.电源电路AC220V电压经变压器T降压,其次级输出近13V左右交流电加至由D1~D4 构成的整流桥输入端,整流后经电容CI滤波得到约10.5V直流电压。
该电压经Rl加到红色发光管LEDI上,将LEDI点亮,表示电源正常。
该电压除了为ICI及继电器提供工作电源外还直接送到水位检测电极C.作为水位检测的公共电位。
2.水位信号检测电路该部分是以四二输入与门电路CD4081为核心并配以五根水位检测电极A—E构成的。
其作用是根据电极实测水位的变化CD4081相应引脚的电平随之变化,满足与门条件时相应输出端电平改变,以驱动输出电路。
其中R2是ICI的电源输入限流电阻,D5与R3及D6与R8起隔离自锁作用,当相应输出端即ICI(10)脚、(3)脚为高电平时将(8)脚、(1)脚锁死,其状态的翻转取决于(9)脚和(2)脚。
C2—C5及R4_R6、R12的作用是滤除干扰信号意外进入控制器引起误动作。
3.输出驱动电路该部分主要由驱动管VTI,继电器Jl、功能选择开关K及输出状态指示绿发光管LED2组成。
功能选择开关K处于“开?位时,继电器Jl被强制动作.其相应触点Jl-I闭合,外接负荷(单相电动水泵或控制接触器)开始工作,输出状态指示绿发光管LED2也被点亮;处于“关”位时,触点Jl-I断开,外接负荷被切断;处于“自动”位置时.Jl动作与否受驱动管VTI的控制.当VTI基极电位高于0.7V以上时则饱和导通,继电器儿得电动作,其触点Jl-I闭合,反之则断开。
二.实际应用分析下图是该型全自动水位控制器实际应用的四种接法,分别对应单控上水池、单控下水池、缺水保护和上下水池联合控制。
1.单控上水池此时电D(绿线)、E(黄线)与电极C(黑线)并接置入水池的最低点,与水池底部接触作为水池(水塔)地线(公共电位);电极A(红线卜一为上水池(水塔)上限液位控制点,水位上升达到A点水位,水与探头接触,水位控制器自动关泵;B隘线卜一为上水池(水塔下限液位控制点,水位下降到B点水位以下,水与探头脱离接触,水位控制器自动开泵,水池充水。
任务五 汽车水箱水位过低报警器的制作

• 例5-3组合电路如图5-16所示,分析该电路 的逻辑功能。
图5-16 例5-3电路图
解:(1)由逻辑图逐级写出逻辑表达式。 为了写表达式方便,借助中间变量P
• (2)化简与变换。因为下一步要列真值表,所以 要通过化简与变换,使表达式有利于列真值表, 一般应变换成与—或式或最小项表达式。
表5-13真值表
1.二—十进制编码(BCD码)
• 在数字电路中一般采用二进制数。用二进 制数表示十进制数的编码方式,称为二— 十进制编码,即BCD码。用一组(4位) 二—十进制码表示一位十进制数。
表5-1
几种常用的二-十进制码
2.字符码
• 目前广泛应用的表示字母、符号的二进制 代码是ASCII码。 • ASCII码采用7位二进制数编码,可以表示 128个字符。
表5-22 可控RS触了器的功能表
(三)JK触发器
• 表5-23 JK触发器的功能表
图5-27JK触发器的逻辑符号
• 例5-4设主JK触发器的初始状态为0,已知输入J、 K的波形图如图5-28,画出输出Q的波形图。 • 解:如图5-28所示。
图5-28 例5-4波形图
(四)D触发器
表5-24 D触发器的功能表
任务五 汽车水箱水位过低报 警器的制作
一、 数字电路基本知识
• (一)数字信号
(a)矩形波 图5-1数字信号
(b)尖顶波
图5-2 实际的矩形波
图5-3 正脉冲和负脉冲
(二)数制
• 数值可以表示长度、质量、表示数值大小 的各种计数方法,最常用的是十进制,它 有1,2,3……9十个数码,用来组成不同 的数,称为计数体制,简称数制。在数字 电路中采用二进制,还有八进制和十六进 制。
水位液位控制器开关水塔水池自动抽水排水缺水保护控制电路板

水位液位控制器开关水塔水池自动抽水排水缺水保护控制电路板水位液位控制器开关水塔水池自动抽水排水缺水保护控制电路板接线参考图::液位自动控制器电路图本例介绍的液位自动控制器采用分立元件制作而成,其特点是液位检测电极上只通过微弱的交流电流,电极不会产生电解反应,使用寿命较长。
电路工作原理该液位自动控制器电路由电源电路和液位检测控制电路组成,如图所示。
图液位自动控制器电路电源电路由电源开关S1、电源变压器T、整流桥堆UR1、UR2和滤波电容器C1、C2组成。
液位检测控制电路由检测电极a~c、控制按钮S2、S3、电阻器R1~M、晶体管V1、V2、发光二极管VL1、VL2、继电器K、交流接触器KM和二极管VD组成。
接通电源后,交流220V电压经T降压后,在T的W2绕组和W3绕组上分别产生交流6V电压和交流12V电压。
交流12V电压经UR2整流及C2滤波后,为Κ及其驱动电路提供+12V工作电压,同时将VL1点亮。
在储液池内液位低于下限时,电极a~c均悬空,T的二次绕组与整流滤波电路之间的回路处于开路状态,V2处于截止状态,V1饱和导通,K通电吸合,其常闭触头K1断开,常开触头K2接通,KM吸合,加液泵电动机M通电开始工作,同时VL2点亮。
当储液池内液位上升至电极c处时,电极a和电极c通过液体的电阻接通,T的V2绕组上的交流6V电压经URI整流、C1滤波及R1限流后加至V2的基极,使V2导通,V1截止,K和KM释放,加液泵电动机M停转。
同时VL2熄灭,K的常闭触头K1又接通。
当液位再次下降至电极a、b以下时,K和KM再次通电工作,电路进人下一个工作循环下。
S2为手动停止按钮,S3为手动强制运行按钮。
在液位处于上、下限之间时,通过S2和S3可任意停止或起动加液泵电动机。
元器件选择R1~R4选用1/4W的金属膜电阻器或碳膜电阻器。
C1和C2均选用耐压值为25V的铝电解电容器。
VD选用1N4007型硅整流二极管。
VL1和VL2均选用φ5mm的发光二极管。
水位控制电路图水位控制器原理

水位控制电路图水位控制器原理1.本电路能自动控制水泵电动机,当水箱中的水低于下限水位时,电动机自动接通电源而工作;当水灌满水箱时,电动机自动断开电源。
该控制电路只用一只四组双输入与非门集成电路(CD4011),因而控制电路简单,结构紧凑而经济。
供电电路采用12V直流电源,功耗非常小。
控制器电路如图1所示。
指示器电路如图2所示。
图1是控制器电路图,在水箱中有两只检测探头"A"和"B",其中"A"是下限水位探头,"B"是上限水位探头,12V直流电源接到探头"C",它是水箱中储存水的最低水位。
下限水位探头"A"连接到晶体管T1(BC547)的基极,其集电极连到12V电源,发射极连到继电器RL1,继电器RL l接入与非门N3第○13脚。
同样,上限水位探头"B"接到晶体管T2的基极(BC547),其集电极连到12V电源,发射极经电阻R3接地,并接入与非门N1第①、②脚,与非门N2的输出第④脚和与非门N3的第○12脚相连,N3第①脚输出端接到N2第⑥脚输入端,并经电阻R4与晶体管T3的基极相连,与晶体管T3发射极相连的继电器RL2用来驱动电动机M。
当水箱向水位在探头A以下,晶体管T1与T2均不导通,N3输出高电平,晶体管T3导通,使继电器RL2有电流通过而动作,因而电动机工作,开始将水抽入水箱。
当水箱的水位在探头A以上、探头B 以下时,水箱中的水给晶体管T1提供了基极电压,使T1导通,继电器RLl得电吸合N3第○13 脚为高电平,由于晶体管T2并无基极电压,而处于截止状态,N1第①、②脚输入为低电平,第③脚输出则为高电平,而N2第⑥脚输入端仍为高电平,因而N2第④脚输出则为低电平,最终N3第11脚输出为高电平,电动机继续将水抽入水箱。
当水箱的水位超过上限水位B时,晶体管T1仍得到基极电压,继电器RLl吸合。
水位报警器电路图

产品说明书:水位达标感应器
【使用说明】如说明书最下方的电路示意图所示,A,B为两个电极。
使用时,将B直接放入容器底部,A放在水位应该达到的位置上。
当水没过A时,扬声器将会有声音放出。
【原理说明】当水位达到A时,A,B两电极间相当于接上了一个电阻,和原来的短路相比,水充当了有电阻的“导线”的角色。
使得三极管VT1得到基极偏流而导通,电容在其中构成振荡电路。
让振荡器工作从而是的扬声器发出声音。
【操作注意事项】(1)开始是滑动变阻器Rx应该位于最大值。
将A.B直接接通后调节Rx。
使得扬声器声音合适。
特别注意不要烧坏三极管。
(2)该装置测水位达标能适合大多数的容器。
不过特别注意的是:如果对于特别大表面积(指水面面积)的容器,因其中水的电阻太大可能出现不发声的情况,所以必须注意两电极间距离不宜过远。
个人测试过,该装置能够至少承受一个人这样的外载电阻。
简易水塔水位控制电路

1 系统组成图图为简易水塔水位控制电路系统组成图,由电源电路,水位检测器,水位范围测量电路,水泵开关电路和显示电路组成。
各部分电路的组成及其用途如下:电源电路:为上述所有电路提供直流电源水位检测电路:利用水的导电性检测水位变化,同时形成回路,形成电信号实现对水位的控制。
水位范围检测电路:利用比较器原理实现水位范围的确定,同时利用迟滞比较器的迟滞性来避免跳闸现象水泵开关电路:完成控制电路和水泵通放水的转换显示电路:利用发光二极管将水泵状态显示出来2 原理电路图采用传感器对水塔水位进行监测,并根据水塔水位的变化将其信号传递给迟滞比较器,经过迟滞比较器的运算、比较、放大,来控制水泵是否工作。
并通过发光二极管来显示水泵的工作状态,易于判断和检修。
迟滞比较器的运用避免了由于水波的波动而造成的水泵的反复的放水与闭合,实现了水塔水位的自动控制。
3 主要单元电路设计3.1电源电路图1如图1为电源电路直接可以从电网供电,通过变压器电路,整流电路,滤波电路,和稳压电路直接将电网中的220V交流电转换成+12V的支流电压。
其各部分功能如下:3.1.1 变压器:采用常规的铁心变压器,将高压转变为低压。
整流电路:采用二极管桥式电路,任务是将交流电换成直流电,这主要靠二极管的单向导电作用,T为电源变压器,作用是将交流电网电压变成整流电路要求的电压价。
其优点是输出电压高,纹波电压小,管子所承受的最大反向电压底。
3.1.2滤波电路:由C1,C2,C3,C4构成,用于滤去整流输出电压中的纹波,本电路采用电容输入式,电容具有平波作用。
使纹波较小,适用于负载电压较高,负载变动不大的电路。
3.1.3 稳压电路:采用三端稳压集成电路,有输入,输出和接地端,内部由启动电路,基准电压电路,取样比较放大电路,调整电路和保护电路组成。
电路中接入电容用来实现频率补偿防止稳压器自激振荡和抑制电路引入的高频干扰,另一方面以减少稳压电源输出端由输出电源引入的低干扰。
任务五汽车水箱水位过低报警器制作

3.异或门
• 式 LA_B__A_B的逻辑运算称异或运算。 • 记作 LAB
表5-9异或门逻辑状态表
图5-13 异或门逻辑符号
任务五汽车水箱水位过低报警器制 作
三、 组合逻辑电路
• 逻辑电路按功能分为组合逻辑电路和时序 逻辑电路两大类。将基本逻辑门电路组合 起来,就构成组合逻辑电路,简称组合电 路。
一、 数字电路基本知识
• (一)数字信号
(a)矩形波
(b)尖顶波
图5-1数字信号
任务五汽车水箱水位过低报警器制 作
图5-2 实际的矩形波
任务五汽车水箱水位过低报警器制 作
图5-3 正脉冲和负脉冲
任务五汽车水箱水位过低报警器制 作
(二)数制
• 数值可以表示长度、质量、表示数值大小 的各种计数方法,最常用的是十进制,它 有1,2,3……9十个数码,用来组成不同 的数,称为计数体制,简称数制。在数字 电路中采用二进制,还有八进制和十六进 制。
输出
A2 A1 A0 000 001 010 011 100 101 110 111
任务五汽车水箱水位过低报警器制 作
用门电路实现逻辑电路
图5-19 3位二进制编码器
任务五汽车水箱水位过低报警器制 作
2.二—十进制编码器
• 二—十进制码由四位数组成。
•表5-17 8421BCD码编码器真值表
任务五汽车水箱水位过低报警器制 作
表5-13真值表
任务五汽车水箱水位过低报警器制 作
• (3)由表达式列出真值表,见表5-13。经 过化简与变换的表达式为两个最小项之和 的非,所以很容易列出真值表。
• (4)分析逻辑功能 • 由真值表可知,当A、B、C三个变量不一
自动水满报警器设计

目录摘要 (I)Abstract (Ⅱ)1 引言 (1)2电路原理图 (1)3工作原理 (2)4 元件参数选择 (2)5 PCB设计流程 (3)6 PCB板的3D显示 (6)7安装与调试 (6)7.1 理论分析 (6)7.2 实际调试过程 (9)8 结论 (9)参考文献 (9)致谢 (9)自动水满报警器摘要自动水满报警器是当今运用十分广泛的报警器产品,在消防部门,公司安全和人们的日常生活都发挥着重要的作用。
该电路设计方法颇多,但其功能都是唯一的,实现水满后自动报警,而工作原理,分析方法,电路调试等都根据具体电路而定,所以对电路工作原理分析和电路安装与调试处理技术犹为重要。
本文从自动水满报警功能出发设计了一个功能较为完善的电路,并对电路工作原理和元件参数选择处理进行了系统的分析,根据工作原理和调试的结果,从所存在的一些问题着手解决,改变电路结构和元件参数,进而更准确地制作完成电路功能。
关键词:报警器;工作原理;PCB制作流程;安装与调试- I -2002级电子信息科学与技术专业毕业论文(设计) 英文摘要AbstractNowadays, automatic water annunciator is used extensively.It plays very important role in fire engine department, company security, and our daily life. There are many ways to design its electric circuit, but it has only one function that it alerts when water is full. Work principle, analysis, depend on the concrete electric circuit, such as adjustment of electric circuit, which is very important to analyze the electric circuit work principle, install, adjust and processing electric circuit. We have designed a more perfect electric circuits based on function of automatic water annunciator and analyze systemically the work principle of electric circuit and selection of component parameter. According to work principle and results of adjustment, there are still some problems. We have solved the problems, and changed the component parameter,and made its electric cirtuit accurately.Keywords:Annunciator ; Work principle ; PCB produce flow ; Installment and adjustment-Ⅱ-2002级电子信息科学与技术专业毕业论文(设计)1 引言现在生活好了,很多家庭都用上了太阳能热水器,其应用太阳能,清洁无污染,实用价廉,深受喜欢。
水塔水位过低自动报警、自动抽水系统

电子课程设计——水塔水位过低自动报警、自动抽水系统水塔水位过低自动报警,自动抽水系统该系统主要由水位开关、显示器、报警灯和水泵抽水灯组成。
当水位到达某一个开关的时,该开关闭合,显示器中显示当前水位。
当水位过低时,过低开关闭合,系统将自动点亮报警灯和水泵抽水灯,以便补水,提升水位。
一、设计任务与要求该水位检测电路主要功能是能显示当前水位,并且当水位过低时,电路能自动报警并且让水泵自动抽水的电路。
基本功能:1、用编号为0-7的开关模拟水塔中的实时水位。
2、当水位持续下降时,0-6号开关顺序闭合,此时当每个开关闭合时,显示器上显示出来当时水塔里的水位情况。
3、7号开关为水位过低警示开关,当此开关闭合时,说明水塔中的实时水位已经过低,则要点亮水位过低报警灯和水泵抽水灯。
二、总体框图↓↓↓↓→→→模块。
1、显示电路由74LS148优先编码器,74LS373锁存器和译码驱动显示电路组成。
0-6号开关依次闭合,信号进入优先编码器进行编码,再以二进制输出。
输出的信号所存起来,锁存器的输出端输出结果通过译码显示电路显示出来。
2、报警电路由一个NE555和外围电路以与报警灯和水泵抽水灯构成。
当代表水位过低的7号开关闭合时,信号则直接进入报警电路,通过多谐振荡器实现报警灯和水泵抽水灯的点亮。
设计思路:该系统的主要作用是检测与显示水位、自动报警和自动抽水功能。
要实现要求的功能的话,我认为把整个系统分为两个部分来看:1、检测与显示部分是用七个开关,在水塔里从上到下依次排列。
当水位下降到某个开关位置的时候,开关闭合,输出信号被送入8-3优先编码器进行编码,编码输出信号经锁存后送入显示电路,显示电路的作用是显示当前水位,从而显示电路把实时水位显示了出来。
2、报警电路的作用是当水塔中水位过低是,引起水位过低开关闭合,开关闭合产生的信号直接通过由NE555组成的多谐振荡器出来的信号直接触发报警灯和水泵抽水灯。
3、报警电路,由于没有报警器,所以选择一个LED灯来表示。
水位报警器

数字电路实验作品报告学院:应用科技学院班级:2009级电子信息工程姓名:学号:设计题目:水位报警器2010-2011学年第二学期6月1日水位与缺水报警器一、设计初衷:用一个水位自动控制器同时对多个楼顶水池进行供水时,常常会出现一些水池缺水或一些水池溢水现象,利用本报警器可在水池出现缺水和溢水时均能发声报警和灯光提示,以告知管理员。
二、工作原理:如下电路原理图:整个电路由一块四二输入与门集成电路CD4011、三极管和继电器等构成。
图中的U1A、Q1和RL1等组成缺水报警控制部分;U1B、U1C、Q2、RL2等组成溢水报警控制部分;D2、D3、D6组成蜂鸣器声响部分。
如果水池有水时,Switch1和switch2之间通过水电阻导通,使U1A的一脚为高电位,2脚通过R3的链接也为高电位,则3脚维持低电位,经R4耦合到Q1的基极,是Q1截止,RL1亦停止吸合,灯断电不亮,蜂鸣器断电不响。
当水池里缺水时,A与B之间失去水电阻而不能导通,UA1的1脚由高电位变成低电位,则3脚变为高电位,经R4耦合到Q1的基极,使Q1导通,RL1亦吸合,即RL1的常开触点闭合,让缺水指示灯得电发光报警,同时,D4导通,使Q3也导通,蜂鸣器通电发出报警声。
缺水控制与溢水控制电路原理相同,只是溢水控制电路中增加了一个反相器,使溢水控制刚好与缺水控制相反。
当水池产生溢水时,switch1与switch2连接在一起(通过水电阻导通),使得4脚为高电平,5脚通过R7的连接也为高电位,则6脚为低电位,经反相器反相,10脚为高电位,有R8耦合到Q2的基极,使Q2导通,RL2吸合,即RL2的常开触点闭合,让溢水指示灯得电发光报警。
同时,D2导通,使Q3也导通,蜂鸣器通电发出报警声。
三、元器件的选择:1)CD4011;2)8050型和8550型三极管;3)1N4007和1N4148二极管;CD4011芯片的功能说明:管脚功能:1A 数据输入端2A 数据输入端3A 数据输入端4A 数据输入端1B 数据输入端2B 数据输入端3B 数据输入端4B 数据输入端VDD 电源正VSS 地1Y 数据输出端2Y 数据输出端3Y 数据输出端4Y 数据输出端VDD电压范围:-0.5V to 18V功耗:双列普通封装700mW 小型封装500mW工作温度范围:CD4011BM -55℃ - +125℃CD4011BC -40℃ - +85℃作品展示:实验心得:通过此次的实验,让我了解了许多关于元器件的检测,以及电路的一些基本设计。
经济实用的自动水位控制电路

经济实用的自动水位控制电路该自动水位控制器由系统电源、水塔水箱高低水位检测控制电路、水源(水井)低水位检测电路、执行继电器、抽水机及指示灯组成。
电路见附图所示。
一、工作原理1.抽水220V市电经变压器变压、整流滤波后为系统供电。
发光二极管D6作待机指示灯。
D7为输出接通指示灯。
当水源的水位低于水位检测XY点时,水位检测三极管Q3截止。
继电器控制三极管Q1截止。
只有水源的水位超过水位检测X点时,由于水的导电性形成通路,Q3的基极得到偏置电压,Q3导通,电路中G点有了高电平,即继电器控制三极管01的基极有了导通偏置电压。
此时,当水塔水箱的水位低于水位检测Z点时,水塔水箱水位检测点之间没有形成通路,水位检测三极管Q2截止,则继电器控制三极管Q1导通,继电器吸合,抽水机开始抽水。
当水源水位被抽低时,Q3基极电位在电容C3的缓冲延时后,因失去导通电压而使Q3截止。
这样,不致因水源水面上下波动荡漾,造成继电器时通时断而烧坏继电器触点或损坏电机。
2.抽、用水过程在抽水过程中,因Q1是导通的,其集电极即E点为低电位。
随着抽水水位升高至低水位检测点Z点时,E点、Z 点之间没有电流通过,Q2的基极为低电位而依然截止。
当抽水水位升高至高水位检测点H点时,H点、Z点之间,由于水的导电性形成通路,电源的正极经检测线AH、高水位检测H点、H点/z点水阻、低水位检测端Z点,再经电阻R2.使Q2的基极得到偏置电压。
Q2导通,Q1的基极为低电位截止,继电器释放,抽水机停机。
在用水过程中,水塔水箱水位下降,低于H点时,电源失去E、H点之间水的电阻形成的通路;因三极管Q1截止,其集电极电位接近电源电压,即E点为高电平,E点、Z点之间,由于水的导电性形成通路。
Q2的基极得到导通偏置电压而导通,使Ql的基极为低电位依然截止,即E点与H 点为同电位,继电器不动作,抽水机处于停机状态。
即使水塔水箱的水面上下浮动荡漾,造成Z点H点的水的电阻时通时断,也因为E点与H点一直为同电位,继电器不致因水面上下波动而时通时断,烧坏其触点或损坏电机。
简易水塔水位控制电路

郑州轻工业学院本科课程设计(论文)题目简易水塔水位控制电路学生姓名杨二兵专业班级电信11-01学号 541101030143院(系)电气信息工程学院指导教师(职称)完成时间 2013年6月25日郑州轻工业学院课程设计任务书题目简易水塔水位控制电路专业电信工程11-01 学号 541101030143 姓名杨二兵主要内容、基本要求、主要参考资料等:主要内容1.阅读相关科技文献。
2.学习protel软件的使用。
3.学会整理和总结设计文档报告。
4.学习如何查找器件手册及相关参数。
技术要求1.要求电路能够通过控制两个水泵实现对水位的控制。
假定水位范围是S1~S2(S1<S2),S为实际水位。
当S<S1时,两个水泵都放水;当S1<S<S2时,仅一个水泵放水;当S>S2时,两个水泵都关闭。
2.要求电路在S1、S2处不能出现跳闸现象,即水泵不能在短时间内反复在放水和关闭的状态之间转换。
3.要求电路能够显示出水泵的状态。
4.要求电路能够手动调节水位控制的范围。
主要参考资料1.何小艇,电子系统设计,浙江大学出版社,2001年6月2.姚福安,电子电路设计与实践,山东科学技术出版社,2001年10月3.王澄非,电路与数字逻辑设计实践,东南大学出版社,1999年10月4.李银华,电子线路设计指导,北京航空航天大学出版社,2005年6月5.康华光,电子技术基础,高教出版社,2003完成期限: 2013年6月30日指导教师签章:专业负责人签章:2013 年 6 月 22日1简易水塔水位控制电路摘要随着科技的发展人们对水位控制的需求越来越多,它不仅要具有控制水位的功能,而且要能自动控制,从而能解放人力,在不需要人为控制的同时它还要能够调节控制水位的范围,我设计的这个电路由电源电路,水位监测电路,水位范围测量电路,水泵开关电路和显示电路组成。
它采用了水压传感器、74LS00、74139、二极管、三极管、稳压管、继电器、三端稳压电路等多种电子元件来实现各部分电路。
水位自动报警器

、水位自动报警器
【实验原理】学习了串联与并联电路,给合以前学过的浮力部分知识,可以自己设计一个水位自动报警装置。
如图6-30 所示,当水位上长,浮子上浮,与 A 端接触,浮子上的导线与绿灯组成串联电路,绿灯亮,表示水位已达高水位线;当水位下降,浮子下降与 B 端接触,浮子上的导线与红灯组成串联电路,红灯亮,表示水位达低水位线。
如果高楼上的供水池装上这么一个报警装置,电工师傅就知道什么时候应该打开水泵抽水,什么时候应该关闭水泵停止抽水。
【制作方法】
振动的形态不同,制造出来的声音也不同。
振动越快,发出的音调越高;振动越慢,发出的音调越低。
水位自动控制器电路图

水位自动控制器电路图目前市售水位控制器大都没有水塔(池)进水指示与保护、报警功能,当水源无水或水泵故障时,不能自动停泵,既浪费电能,又容易烧毁电机。
当水位低于下水位且泵无水时,不能及时停泵报警,提醒用户。
因此,其安全性与可靠性尚有不足。
本文介绍的两种水位自动控制器,都是为解决上述问题而设计的。
图1是S Z K-Ⅱ型水位自动控制器电原理图。
同相器I C3、I C4组成大回差施密特触发器。
R12、C4为积分电路,能有效地消除交流电源引入的干扰。
R14、R13使I C4输出呈施密特特性。
通过水塔地电极与下、上水位电极跟水顺序接触,改变I C3输入电压,实现水位自动控制。
I C1、I C2、I C3的输出共同控制三极管V T1。
V T1导通时,C3放电,I C5输出为负。
V T1截止时,V D7反偏,电源经R10向C3充电,延时开始。
到达延时时间后,I C5输出变正,电路进入保护或报警状态。
延时时间应调整为略大于开泵至水塔有进水所需的时间。
V T1截止有两种情况:1、I C1与I C2输出都为正,即水位在上水位电极以上和进水口仍有水流。
这是专为自来水压力不正常须装加压泵或自来水与井、河水并用的环境而设计的报警。
当自来水压力能自流上水塔时,水满报警,提醒用户关闭水阀。
如果水塔加装水位浮球阀,并使浮球阀关水线在上水位电极上方,则不需报警便能自动控制。
这时应拆去V D5、V D6,并将V T1发射极接电源负极,使I C2输出开路以消除本项报警。
2、I C1、I C2、I C3输出都为负,即水位在上水位电极以下、水泵工作和水抽不(未)上水塔时的状态。
这时,在延时时间内,水塔进水口若有水流,则I C1输出变正,V T1导通;若仍无水流,则I C5输出因C4充电电压上升而变正。
V D8、R15能加速I C5翻转和消除电源波动的影响。
I C5的输出分两路,一路为V T2提供基极电流,产生鸟叫声报警;一路通过V D9加至I C4输入端,使其输出变正,水泵停泵,同时通过R11作用于I C3输入端。
稳压电源及水位报警设计演示文稿

水位电路原理
PCB电路布线
3D图和实物图
整个系统实物图
1.2V-24V可调电源电路
正负5V电压输 出电路、3.3V 电压输出电路原 理及整流滤波电 路。
PCB电源电路布线如图
电源电路3D图
电源硬件实物图
水位报警电路设计原理
Байду номын сангаас
CD4066芯片
CD4066芯片 是四双向模拟开关 主要用作模拟或数字信号的多路传 输。 CD4066 的每个封装内部有 4 个独立的模拟开关,每个模拟开 关有输入、输出、控制三个端子, 其中输入端和输出端可互换。当控 制端加高电平时,开关导通;当控 制端加低电平时开关截止。模拟开 关导通时,导通电阻为几十欧姆; 模拟开关截止时,呈现很高的阻抗, 可以看成为开路。模拟开关可传输 数字信号和模拟信号。
稳压电源及水位报警带你路设计
11电信班
苏维林
稳压电源及水位报警电路设计
方案设计:整个系统工作需要三个部分组 成,电源、水位报警硬件系统、水位信息 采集。三者的关系如下:
电源
水位报警系统
水位信息采集
电源原理
所谓电源就是要产生一个稳定的直流电压, 能供使用者使用。原理图如图:
正负15V、12V电源电路
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
水位报警器电路图
发布: 2011-6-8 | 作者: —— | 来源: 华强电子网用户| 查看: 320次| 用户关注:
这里介绍的水位报警器电路十分简单,它仅用一节五号电池作电源,体积小巧,和普通烟盒大小相仿.它可以用于水缸,水池和洗衣机里水位报信,也可以用于婴儿报尿,十分实用.
这里介绍的水位报警器电路十分简单,它仅用一节五号电池作电源,体积小巧,和普通烟盒大小相仿.它可以用于水缸,水池和洗衣机里水位报信,也可以用于婴儿报尿,十分实用.
以下是一种水满声光报警器电路图,具有声光同时报警功能,可用于洗衣机,水塔的水位控
制上。
该电路耗用的电流很小,以致电池的贮存期限成了限制因素,所需电流只是晶体管的漏电流。
该电路虽然是一种水位报警器的形式,但若变换一下探头,也可用作雨量报警器或短路报警器;探头两端存在的从零到1M欧的任何东西都可使该电路触发。
Q1作为一个开关向单结晶体管Q2供电。
报警信号频率受此值C1/R2的控制。
通过脉冲开关Q3的通和断,给喇叭提供信号,几乎任何硅NPN管都可用作Q1和Q3,任何单结晶体管都可用作Q2.
低功耗断线式防盗报警器电路
上传者:dolphin浏览次数:74分享到:开心网人人网新浪微博EEPW微博
低功耗断线式防盗报警器电路电路原理它由互补型音频振荡器和晶闸管触发电路两大部分组成。
图中,R1为三极管VT1提供基极偏置电流,电路在静止警戒状态时,由于a、b间的短路导线L存在,VT1截止,晶闸管VTH门极无触发电流而关断,后续电路失电不工作,扬声器B无声。
如果有盗贼破门或破窗而入,短路线L被扯断,VTl由R1获得基极偏
流而导通,VTl发射极电流经R2触发晶闸管VTH,使VTH开通,盗情指示灯LED 即点亮发光,由三极管VT2、VT3组成的互补型音频振荡器起振工作,扬声器B即发出报警声响。
由于晶闸管工作在直流回路,一旦开通,其门极就失去了控制作用,此时即使是盗贼把L短路线重新接通,电路仍报警不息,只有主人切断电源开关S才能解除警报,所以本电路具有一定的防破坏性。
元器件选择与制作
VT1应采用9014型硅NPN三极管,要求β≥150。
如果取用β值更高的晶体三极管,电阻R1的阻值还可以进一步加大,使整机静态功耗更小。
VT2用9013型等硅NPN三极管,β≥100;VT3用9012型硅PNP 三极管,β≥50即可。
VTH用触发电流较小的微触发单向晶闸管,如2N6565、MCR100—6型等。
LED最好采用高亮度红色发光二极管。
R1~R5均可用1/8W型普通碳膜电阻器,C1~C3可用CT4型独石电容器。
更改电阻R4或电容C3的数值可以调整电路报警时发声音调的高低,可视各人喜爱确定。
β用YD57—2型等8Ω小型电动扬声器。
电源G用5号碱性电池四节。
S为小型拨动式开关,报警器长期不用时,可用它切断电源。
断线式防盗报警器的印制电路板见图下部所示,印制板可用35mm×40mm单面环氧树脂基质敷铜板加工制作,用小刀刻制揭取不需要的铜箔条,也不必钻孔,直接将电子元器件焊在铜箔面上即可。
如放在家中使用:a、b间短路线L应采用φO.07mm或更细的漆包线,也可用普通多股软导线,去掉外面绝缘皮,把内部细铜丝一根一根抽出,再分别头尾相连。
这种细铜丝比漆包线更具隐蔽性和易扯断。
将它布置在门或窗的周围,或者系在贵重物品上,为提高灵敏度,细铜丝可用绝缘支架布置,并尽可能地把线拉紧,这样,只要轻轻一碰,铜丝即断。
线的两端接在报警器的a、b接线柱上,合上电源开关S就可以了。
如果有人推开门窗或挪动物品,势必扯断漆包线,警报声就会大作。
如用于出差或旅行:当乘坐火车或长途汽车时,可将报警器放在袋子里,短路线可用普通细漆包线,将其从旅行袋内伸出绕过车辆行李架铁杆再回入袋中,导线的两端接在a、b接线柱上,合上
开关S,锁好袋子,你就可以放心休息。
如果有人盗走袋子,一定会扯断漆包线,此时你的旅行袋就会发出响亮的报警声。
用于旅行袋(箱)防盗报警时,电源G应采用6F22型9V。