离子风机中文版使用手册

合集下载

GTF-481离子摆动直立风扇用户手册说明书

GTF-481离子摆动直立风扇用户手册说明书
-9-
Notes
If the power cord is damaged, it shall be returned to Maintenance Department of the company or commercial agent for replacement Attention! by professional staff.
If the fan is found malfunction, it shall be return to maintenance centre for repair.
移動風扇時,請先 關閉電源並 下電 源插頭,待風扇停 止後輕輕移動風扇,以 免風扇受到強烈撞擊。
切勿將風扇放在高 溫的環境中使用。
風扇運作時, 切勿把手指 或雜物伸入 網罩。
兒童或長者必須在監 管情況下才能使用風 扇,以 確保安 全。
如出現故障,應送往指定維 修點由專業人員維修。
-2-
本產品不適合以下人士使用, 包括兒童、殘缺人士或缺乏 經驗使用者,除非有負責安 全人員在旁監督或指示產品 的使用方法。
包裝清單
項目 風扇 遙控器
底座
固定螺絲 說明書 保養卡
數量 1 1 1 4 1 1
單位 台 個 套 粒 本 張
-8-
Read carefully before attempting to assemble, install, operate or maintain the product described. Please take good care of this manual for the purpose of reference.
Before moving the unit, always switch it off and unplug it. Move the fan gently after the wind wheel stops in order to avoid fierce bash.

BFN-702+NET 悬挂式离子风机使用说明书

BFN-702+NET 悬挂式离子风机使用说明书

BFN-702+NET悬挂式离子风机使用说明书BFN-702+NET悬挂式离子风机,出众的消除静电性能,是电子生产线,包装台、维修站及风淋设备等静电防护区域防止静电污染及破坏的理想设备。

BFN702+NET overhead DC Ionizing Blower has outstanding Ion-eliminating performance,it is your ideal device to prevent static pollution and damage in the ESD area for electronic production line and maintenance.注意:Note安装使用前请仔细阅读本手册,所有BFN系列的静电消除设备不可在易燃易爆环境下使用,禁止使用普通的临时插座作为电源,所有BFN系列的离子风机必须使用配备安全标准电源连接线上的电源插座,不可更改或使用在不可靠接地的电源插座上。

Please read the user guide carefully before operation.All BFN static eliminate series cannot be used under flammable and explosive environments.Don’t use temporary common socket as power,all BFN Ionizing blower series must be used with the power socket which has standard power cable,do not use the socket which not grounding.安全:SafetyBFN-702+NET离子风机具有可靠的安全回路设计及良好的安全接地配置,同时风机在前后可装卸的面罩位置装有微动开关,可以在前后面罩意外脱落时及时断开供电电源,避免发生安全事故。

DTRY-ELB01 DTRY-ELB02单 双头型空气吹风离子风机说明书

DTRY-ELB01 DTRY-ELB02单 双头型空气吹风离子风机说明书

Instruction ManualAir Blow Single Head-type Ionizer【DTRY-ELB01】Air Blow Twin Head-type Ionizer【DTRY-ELB02】Thank you very much for your purchase of DTRY-ELB01/DTRY-ELB02. Although this Product is not classifiedas a high-voltage device under any electrical equipment standard, it uses a high voltage of 2000 V. Please readthis manual diligently to handle this Unit in a careful and correct manner. Keep this manual on hand for yourreference and consult it repeatedly as required.Safety PrecautionsCaution1. Product OverviewThis product is an Air Blow-type Ionizer (static electricity eliminating device) capable of immediately solving anyproblems that occur in connection with static electricity. By using ionized air it generates, the Unit canpromptly and efficiently eliminate the static electricity charged on electrified bodies to control any problemsoccurring from static electricity.3.Contents of the PackageMain Unit.....................................................1 UnitDischarge Needle.........................................1 (attached to the Main Unit before shipment)Throttle Valve:..............................................1 piece (attached to the Main Unit before shipment)Grounding Lead Wire (2 m).........................1 lineSelector switch protection seal.....................1 sheetInstruction Manual (this book)....................1 bookletPower supply signal cable (2 m)............................1line4.Appearance5-1 Method of Installation○When the ionized air is directly blown out from the Nozzle:Screw the Air Nozzle selected onto the Main Unit of the Ionizer until it is firmly settled on the Unit.Aim theNozzle at an electrified object to allow the ionized air to be blown over the object.○When the ionized air is to be transferred to the electrified objects from the Nozzle through a tube:Screw the standard Nozzle separately available onto the Main Unit of the Ionizer until it is firmly settled onthe Unit. Insert a selected tube into the standard Nozzle, and aim the ionized air outlet to the electrifiedobject to allow the ionized air to be blown over the object.5-2 Method of Mounting○Mount the Main Unit at the specified position of the machine by using the mounting holes (4-Φ4.5 mm) on theMain Unit. Make sure that the Nozzle part of the Ionizer does not get in contact with the metal frame of themachine when mounting Unit.5-3Wiring with the Power Source○Supply 24 V DC power to the Unit by using the accessory power signal cable.If 100 V AC power source is to be used, use the separately available AC Adapter (DTRY-ELC04).5-4 Wiring for Grounding○When using a grounding wire for grounding the Ionizer, make sure that the wire is properly connected to theground.5-5 Air Piping○Use the air as the fluid for discharging.○Attach an air tube (with an outside diameter ofΦ6 mm) to the air inlet of the Ionizer.○Connect the air tube via the regulator to the air supply.○Supply cleaned air (not containing water or oil) to the Ionizer.5-6 Setting of Contacts for Abnormal Output○Confirm that the cable is not connected to the connector and that the power is not supplied to the Unit.○Shift the NO /NC selector switch to the desired position by usinga precision screw driver, etc.○○After the contact setting is completed, be sure to paste the contact switch protection seal supplied with theproduct.6.Wiring Diagram7. Operation(1) Install the Ionizer at the specified position. Make sure that the power source wiring, the grounding wiring,and the air piping have been correctly carried out.(2) Supply the air appropriately pressure-regulated by the regulator to the Ionizer. (See the table under "AirPressure Working Range" under "2. Specifications" for the working range of air pressure.)(3)Supply the 24 V DC power to the Unit.(4)Confirm that the green LED on the Main Unit of the Ionizer is lighted.8.Maintenance and Precautions○Make sure that the Unit is installed at the location not exposed to splashing of water or oil, etc.In case wateror oil is attached to the Unit, use a piece of cleaned cloth to clean the Unit. When cleaning the Unit, pay specialattention to the high-voltage output terminal part to prevent it from being damaged.○Attachment of contamination to the tip of the Discharge Needle will deteriorate the static and eliminationeffect. If deterioration of the static elimination effect is observed, clean the Needle using a nylon brush etc.(Never use a wire brush for cleaning the Needle.)○The Discharge Needle is a consumable material and requires occasional replacements. When replacing theNeedle, use the dedicated tool (DTRY-ELB21) for the correct control of torque. (The correct tightening torque:15 to 20N・cm). Application of an inappropriate torque may damage the screw on the Main Unit.Type of Discharge Needle for replacement: DTRY-ELB11○Do not turn ON the Ionizer immediately after you have turn it OFF, or else and abnormal output is supplied.After turning OFF the Ionizer, wait 1 second or more before turning it ON again.○The Abnormal Output Circuits will start working about 2 seconds after the power is turned on. Pay specialattention when designing the Abnormal Detection Circuits when this Product is to be built into a system.○Make sure you turn ON the power to the air-blow type Ionizer after you turn ON the air to the Unit. TurningON the power to the Unit before turning ON the air will cause the internal density of ozone to rise, which mayadversely affect the Unit and/or the environment.○Make sure that turning ON/OFF the power to the Ionizer is carried out at the power input side(the DC 24 Vside).○The tube is a consumable material, requiring occasional replacements. If you notice it has become softened ordeteriorated, make sure to replace it with a new one.9. Troubleshooting○If no red or green LED is lighting:→Check the input power supply of 24 V DC to confirm that it is correctly supplied.○If the red LED is lighting:→Check the metal cap or Nozzle to confirm that it is not touching the grounded body.→Check the metal cap to confirm that it is not loosened→Remove the metal cap and clean the Main Unit surrounding area of the Discharge Needle and theinsulated area using a clean cloth damped with isopropyl alcohol, and attach the cap again.→Check the grounding wiring to confirm that grounding is properly carried outJUST CONSULT USKOGANEI CORPORATIONOVERSEAS DEPARTMENT3-11-18 Midori-cho, Koganei-shi Tokyo 181-8533, JAPANTEL: 042-383-7271 FAX:042-383-7276Internet Home Page URL: http://www.koganei.co.jp*Please understand that the appearance and the specifications of this Productmay be altered without advance notice for improvements.MAX DC24V50mA。

赛威乐 XY-028离子风扇 说明书

赛威乐 XY-028离子风扇 说明书

賽威樂XY-028離子風扇使用說明書特點:賽威樂XY-028離子風扇是一部優越的靜電消除專用桌上型風扇。

賽威樂XY-028離子風扇具有下列優點:●安裝迅速。

●中和靜電迅速。

●離子氣流覆蓋面積大。

●可調節出風量。

●附有離子發射針凊潔刷。

●附電離子指示灯。

●離子風扇附接地保護。

離子風扇作用原理:賽威樂XY-028離子風扇可產生大量的帶有正負電荷的氣流,可將物體上所帶的電荷中和掉。

當物體表面所帶為負電荷時,它會吸引氣流中的正電荷,當物體表面所帶為正電荷時,它會吸引氣流中的負電荷,從而使物體表面上的靜電荷被中和,達到消除靜電的目的。

賽威樂XY-028離子風扇提供可調風速功能,風力大小可依需要做調整。

電離器:電離器在高壓發生裝置產生的低電流高電壓作用下,形成一個穩定的高壓電場,電離空氣形成離子體,由氣流帶出到達物體表面,達到中和靜電的目的。

電離器上有專用的清潔器,可以清除離子發射針上的積塵,保持電離器的正常工作。

賽威樂XY-028離子風扇設計有離子平衡電路,可以達到正負離子的自動平衡。

賽威樂XY-028離子風扇可以解決因靜電作用引起的生產胎問題,如靜電引起的吸麈問題,塑料製品加工時的粘合問題及靜電排斥引起的零件損壞問題。

賽威樂XY-028離子風扇產生電離子風束來覆蓋目標區域,風束中和靜電時間由多種因素所决定,最重要的兩個因素,是離子風扇的距離和風速。

空氣離子不停地相互中和,陽離子及負離子通過靜電相互吸引,形成這些電荷的轉移並且重組。

高風速能使它們與更遠處的正負離子中和,風速越大中和靜電越快。

使用離子風扇進行產品裝配時,電離氣流應盡可能覆蓋工作區,這樣對物體表面的正負電荷才能提供很好的中和,使其保持最佳中和狀態。

本公司另有其它機種可提供更大的覆蓋面積,可來电索取目錄。

注意事項:安裝操作前須詳讀使用說明。

操作前必需接地。

避免在易燃或易爆的環境下使用本機。

請勿擅自拆開本機做任何維修。

使用方法:賽威樂XY-028離子風扇輕便易操作且使用壽命長機體以U型架配合M6直徑梅花螺絲可方便且快速調整好出風角度。

离子风机测试操作指南

离子风机测试操作指南

PQA Monitor组工作手册离子风机测试操作指南MS Wang 10/05/2004PQA Monitor/PQA /MPIE/DGN2一、工作概述离子风机和BAR是生产过程中消除静电的重要工具和设备之一.但由于离子风机本身结构设计上的局限,DC 和AC 类型的离子风机和BAR存在离子发射针氧化的问题,导致正负离子数量不等,从而在其覆盖区域内产生了静电荷的积累,对产品优率产生不利影响.为了保证所有的离子风机和BAR正常运行,就需要借助监控仪器CPM(Charged Plate Monitor)来测试它的性能.目前,我们主要测试它的两个性能参数:平衡电压和衰减时间即B-V(Balance Voltage) ,D-T(Decay Time).二、测试仪器设备及使用方法1.仪器设备名称:CPM-156A /1572.仪器设备配件:CPM 机身、电荷平板、接地导线、配套电线、充电器等.3. 测试仪器设备介绍(以CPM-156A为例):3.1仪器简介The Trek Model 156A Charged-Plate 测试系统可在任何环境中提供定量准确的离子测试结果。

它使用一种新的charged-plate测试设计,利用一个高电阻和高电压跟随器来检测离子收集板的平板电压。

这种方法使测试容量独立于外部平板的外形尺寸,离子收集板的测试容量及尺寸都可根据测试的实际需要来设置。

3.2仪器面板3.2.1仪器前面板1)FULL CHARGE 显示灯:充电指示灯。

当电池充满后,该指示灯将点亮。

充电完全的电池可以供仪器工作8小时。

2)MODE Switch: 工作模式转换开关。

仪器提供三种模式。

正延迟模式、负延迟模式和漂移模式。

该转换开关与TEST/RESET 一起可以对仪器的起动电压和停止电压进行调节。

3)LOW BATTERY 指示灯:电池低压报警指示灯当电池电量可供工作时间小于30min时,该指示灯将显亮。

4)POWER Switch:电源开关。

Simco-Ion Endstat 2020 台式离子风机 使用指南说明书

Simco-Ion Endstat 2020 台式离子风机 使用指南说明书

M Bench-top Ionizing Air BlowerENDSTAT 2020Simco-Ion’s Endstat 2020 ionizing air blower provides economical control of electrostatic charges over a targeted work surface area. It provides protection from the destructive effects of Electrostatic Discharge (ESD) by neutralizing static charges in the work environment.The Endstat 2020 ionized air blower produces airflow enriched with positive and negative air ions. Directing the ionized airflow on an object that has an electrostatic charge will neutralize the charge. Surfaces with negative charge will draw positive ions and surfaces with positive charge will draw negative ions. The air ions act as charge carriers, neutralizing the surface.The Endstat 2020 is suitable for a variety of applications. It uses a two speed fan to provide an adaptable airflow. Ionization is produced using an AC corona discharge ionizer and AC high voltage transformer. AC ionization technology provides for economical, reliable static control. Features Benefits• Compact design• Perfect fit for complete bench-top work area ESDprotection• Easy to install and operate• Convenient front panel controls for bloweroperation• Two speed fan control• Application specific optimized performance • Built-in emitter cleaner• Easy to maintain long-term ESD protection• Electrically grounded metal enclosure• Ensure durability even under the most extremeworkstation conditions• Inherent balance to ±15V• Designed for electronic assembly andmanufacturing applicationsIonization Solutions W W W.SI M C O-I O N.C OSpecificationsw o r l d w i d e l e a d e r s i n s t a t i c c o n t r o lSimco-IonTechnology Group1601 Harbor Bay Pkwy, Ste 150 Alameda, CA 94502Tel: 800.367.2452 (in USA) Tel: 510.217.0600*********************RoHS 2 Compliant 230V, 50 HzEmitter Point CleanerThe Endstat 2020 features a built-in manual emitter point cleaner. Using the emitter point cleaner takes only seconds. Cleaning the emitter points removes any accumulated contamination, restoring full ionization performance andbalance. This keeps your Endstat 2020 working in top form for the life of the unit.ApplicationsThe Endstat 2020 is designed for electronics and manufacturingenvironments. It can be used with sensitive electronic components or where materials are difficult to work with due to electrostatic charge. Used with sensitive electronic components, the Endstat 2020 helps to eliminate damaging ESD events. The Endstat 2020 will also reduce or eliminate dirt or particle attraction on surfaces due to electrostatic attraction (ESA).Ordering InformationDS-Endstat 2020_V3 - 10/14 © 2014 Simco-Ion All rights reserved.High fan speed.Discharge Times Performance。

11--FWI-GC-011离子风机操作指导书

11--FWI-GC-011离子风机操作指导书

文件编号:FWI-GC-011
A/0
编制
:FWI-GC-011
A/0
富国工业(惠阳)有限公司-手机组装部
离子风机操作指导书
Docume class w文件类别 SOP Drganization date Revise date 编制日期 修订日期 2014.12.02 操作步骤 Operation steps Edition class Page number 版 本 页 次 A/0 1/1 图示 Icon
核准
审核
1.把电源接好,打开开关,指示灯亮起,如不亮则通知线上干部。
2.作业时,把离子风扇角度调节好,然后锁定固定旋钮。
3.风量大小可以根据作业时,按顺时针方向转动开关即可。
注意事项: 1.作业时,离子风扇一定要打开。 2.离子风扇一定要正对作业区域。
相关报表:
M/C样式: 1.M/C名称:离子风机

ESD静电消除离子风机使用

ESD静电消除离子风机使用
工作电流;电源适配器输出0-1A;
有效覆盖:400MM*1200MM;
工作温度:-50℃—70℃;
机身尺寸:145MM*86**250MM(L*W*H)
重量:3KG;
平衡电压:0V±10V;
中和时间:≤2S;
测试仪器:ME-268A;
测试条件:将测试板放在正对离子风机吹风口300MM处,将风量调节最大,不
带过滤网,右1000V至100V,湿度≤75RH;
测试依据:GJB-1997,IEC61340-5-1;
七产品维护
本产品长期使用,放电针会积累灰尘,影响产品正常运行,请根据车间防尘等
级不同,定期清理,具体清理如下:
1)撤下进风口网罩用吹尘抢吹放电针;
2)撤下进风口网罩用所配的防静电毛刷进行清理;
八应用领域:
+30);
2,在离子平衡度设置选项下,按 键,进入IP地址设置选,按 和
键进行IP地址设置(IP地址设置范围1—64);
3,在IP地址设置选项下,按 键,进入报警上下限设置,按 或
键设置报警值(范围-30—+30);
4,请所有参数设置完闭,关闭机器,然后同时按下 , , 开
机,离子风机进入禁止设置状态,下次要重新设置,用同样的方法打开,进
PCB加工生产;
液晶屏组装生产;
手机,手提电脑,数码相机组装生产线;
各种需要消除经典的场合
四操作说明:
一)风速调节:
1,按 键,风量显示数据加大,同时风量也随之加大;
2,按 键,风量显示数字减少,同时风量也随之减少;
二)模式设置:
设置完成后,闪烁五次回到正常工作界面
1,正常工作状态下按 键,进入离子平衡度补赏值设置选项(离子平衡设置值闪烁),按 或 键设置离子平衡度补赏值大小(补赏值范围-30—

离子风机测试操作指南

离子风机测试操作指南

PQA Monitor组工作手册离子风机测试操作指南MS Wang 10/05/2004PQA Monitor/PQA /MPIE/DGN2一、工作概述离子风机和BAR是生产过程中消除静电的重要工具和设备之一.但由于离子风机本身结构设计上的局限,DC 和AC 类型的离子风机和BAR存在离子发射针氧化的问题,导致正负离子数量不等,从而在其覆盖区域内产生了静电荷的积累,对产品优率产生不利影响.为了保证所有的离子风机和BAR正常运行,就需要借助监控仪器CPM(Charged Plate Monitor)来测试它的性能.目前,我们主要测试它的两个性能参数:平衡电压和衰减时间即B-V(Balance Voltage) ,D-T(Decay Time).二、测试仪器设备及使用方法1.仪器设备名称:CPM-156A /1572.仪器设备配件:CPM 机身、电荷平板、接地导线、配套电线、充电器等.3. 测试仪器设备介绍(以CPM-156A为例):3.1仪器简介The Trek Model 156A Charged-Plate 测试系统可在任何环境中提供定量准确的离子测试结果。

它使用一种新的charged-plate测试设计,利用一个高电阻和高电压跟随器来检测离子收集板的平板电压。

这种方法使测试容量独立于外部平板的外形尺寸,离子收集板的测试容量及尺寸都可根据测试的实际需要来设置。

3.2仪器面板3.2.1仪器前面板1)FULL CHARGE 显示灯:充电指示灯。

当电池充满后,该指示灯将点亮。

充电完全的电池可以供仪器工作8小时。

2)MODE Switch: 工作模式转换开关。

仪器提供三种模式。

正延迟模式、负延迟模式和漂移模式。

该转换开关与TEST/RESET 一起可以对仪器的起动电压和停止电压进行调节。

3)LOW BATTERY 指示灯:电池低压报警指示灯当电池电量可供工作时间小于30min时,该指示灯将显亮。

4)POWER Switch:电源开关。

离子风机测试操作指南

离子风机测试操作指南

离子风机测试操作指南【前言】离子风机是一种常用于电子设备、实验室和清洁工作中的工具,通过产生大量高浓度负离子,能够中和空气中的静电,去除空气中的尘埃和异味,提供一个清洁、舒适的工作环境。

本文档旨在向使用者介绍离子风机的测试操作指南,帮助用户正确地进行离子风机的测试和使用。

【一、离子风机的测试准备】1. 根据离子风机的品牌和型号,阅读并理解离子风机的使用说明书,了解离子风机的基本工作原理和操作要点。

2. 确保在操作离子风机之前,所有相关设备和工具已准备就绪,包括电源线、测试仪器(例如测试笔、电压表等)、绝缘手套等。

【二、离子风机的测试步骤】1. 将离子风机置于平稳、通风的工作台上,并打开离子风机的电源开关,确保风机处于工作状态。

2. 使用测试笔(或电压表),将笔头贴近离子风机的负离子出风口(通常位于离子风机的顶部或侧面),观察测试笔的指示灯(或读取电压表的数值)。

如果测试笔的指示灯亮起(或电压表显示有电压输出),则表明离子风机正常工作,正在产生负离子。

3. 切换测试笔至正离子测试模式(若支持),将测试笔的笔头贴近离子风机的正离子出风口(通常位于离子风机的底部或背面),再次观察测试笔的指示灯(或读取电压表的数值)。

如果测试笔的指示灯亮起(或电压表显示有电压输出),则表明离子风机正常工作,正在产生正离子。

4. 如果测试过程中发现离子风机无法正常工作(例如指示灯不亮、电压表无输出等),则应停止使用离子风机,并按照使用说明书中的故障排除方法进行检查和维修。

【三、离子风机的使用注意事项】1. 在操作离子风机时,建议戴上绝缘手套,以避免触电或因静电放电引发意外事件。

离子风机测试操作指南

离子风机测试操作指南

离子风机测试操作指南1. 引言1.1 目的本文档旨在提供离子风机测试操作的详细步骤和注意事项,以确保正确使用并评估该设备的性能。

2. 设备概述离子风机是一种用于去除空气中静电荷、粉尘等有害物质,并改善环境空气质量的装置。

其工作原理基于产生正、负两极之间高压差来释放大量带电颗粒。

3. 测试前准备在进行离子风机测试之前,请务必完成以下准备工作: - 检查设备是否完好无损;- 准确定位需要清洁或处理的区域;- 清理周围环境,确保没有干扰因素存在。

4. 连接与设置将离子风机连接到适当且稳定可靠地电源上,并按照制造商提供说明书进行合适参数配置(如功率调节)。

5. 开始实验执行以下步骤开始实验:5.1打开主控面板:根据产品手册将主控面板启动按钮从“关”转至“开”的位置。

注意:请确保操作人员已经穿戴防静电手套和鞋,以避免对实验结果的干扰。

5.2选择测试模式:根据需要选择合适的离子风机工作模式(如正、负极性)。

注意:不同工作模式可能会产生不同效果,请根据具体情况进行调整。

6. 数据记录与分析在实验过程中,及时记录关键数据,并使用统计软件或其他方法进行数据分析。

主要包括:- 离子浓度;- 温湿度变化;- 静电荷消除时间等指标。

7. 结束实验实验结束后,请按照以下步骤关闭设备并做好清理工作:7.1关闭主控面板:将主控面板启动按钮从“开”转至“关”的位置。

注意:在断开电源之前请先切断所有连接线路上的供应电压, 并且让设备自然放置一段时间再移动它.8. 安全注意事项使用离子风机时需特别注意以下安全事项:-不得擅自改装该设备;-操作人员必须接受相关培训并佩戴个人防护用品;-如发现异常情况或故障,请立即停止使用并联系维修人员。

9. 附件- 离子风机产品手册;- 实验数据记录表格。

10. 法律名词及注释在本文档中,涉及的法律名词和相关术语解释如下: [请根据实际情况添加]。

me-287离子风操作指导

me-287离子风操作指导

me-287离子风机性能分析仪中文说明书特点:1.测试、显示和存储电压、衰减时间、温度和湿度全合一2.优于现在ESD3.3 离子风消电器周期检查标准的要求3.平衡与衰减测量4.高性能价格比5.手持,电池工作6.微处理器7.内置自检8.一年保修9.有手动和自动测试离子风消电器平衡与衰减性能,可存储10个数据10.在衰减模型时内置的高压发生器产生1050伏电压,显示从1000V衰减到100伏的时间11.在平衡模型,显示绝缘板电压、测试时间和正负电压12技术指标充电平板:4.3 厘米×10.2 厘米可选配充电平板:15 厘米×15 厘米的金属板,需另行购买,强烈推荐客户购买,使用此平板可使结果更加准确。

充电器:±1100v, selectable polarity场强表:±5% of reading, ±2% typical漂移:<±4V in 90s, ±2V typicalTrip Points: Fixed 1000V and 100V带电平板:1.7X4 英寸(周长约10.6英寸)平板电容:25pF自放电<10% of full scale in 200s 显示:LCD计时器:最大200.0s,分辩率0.1s 场强表:±1250V, 1V resolution 电池:9V (40小时)体积:(206 x 102 x 48 mm)重量:(0.63kg)由于可能受到电压波动、环境空气湿度等因素影响会形成离子平衡的偏移〔残余电压〕。

偏移量标准:OV±10V。

kesd离子风机KF-80AH说明书

kesd离子风机KF-80AH说明书

kesd离子风机KF-80AH说明书
KESD离子风机的使用环境:
离子风机使用温度:0-40度无结露,使用环境湿度:30-70%RH 无水滴凝结,距离物体表面30-90厘米,外接电源电压:DC24V或AC220V。

KESD离子风机特点:
配有正常工作和异常工作的指示灯,更快发现问题;
特殊钨合金放电针,长期使用不易磨损;
独特外观设计,使风机工作性能做到目视化管理;
自动离子平衡系统,离子平衡可达到-10V~+10V以内
KESD离子风机安装:
将离子风机置于台面上或悬挂于台面上方,接上接地线,接上电源;
打开风机,调节风机气流到所需工作区域,旋紧风机两边的紧固螺母即可开始工作。

KESD离子风机工作原理:
利用空气电离产生大量正负电荷,并用风机将正负电荷吹出。

形成一股正负电荷的气流,将物体表面所带的电荷中和掉。

当物体表面所带为负电荷时,它会吸引气流中的正电荷,当物体表面所带为正电荷时,它会吸引电流中的负电荷,从而使物体表面上的静电被中和,达到消除静电的目的。

ME-268A离子风机测试仪使用说明书

ME-268A离子风机测试仪使用说明书

ME-268A离子风机测试仪使用说明书目录第一部分技术参数第一页第二部分概述第二页第三部分操作第四页第四部分维修第六页附录1 可调计时器综合静电测试仪第七页充电板/探头组合件:按照EOS/ESD协会标准设计标准三脚架安装尺寸:6“*6”容量:整个充电测试电路带一个20皮法的充电板(±2皮法)充电板自动放电:在25℃,50%RH条件下,能在5分钟内将设定的静电压降至原来的10%以上电源:静电测试仪:范围:0-±7500伏;0-±2000伏开关可调精度:高于2%偏移值:10分钟到90%满刻度变化仅需不到100ms时间输出:将输入值分成1000份,电容阻抗为100W计时器:满刻度的999.9%(>16分钟),0.1秒,清晰度电源:117或220伏±10%(工厂预设),50/60Hz,5磅第二部分概述268A型综合静电测试仪分成两个部分,每个部分均采用十脚线缆连接,附加在充电板上的顶部结构就是测试仪的部分,使用时需放在测试现场,带控制及显示器的下面部分需放在便于操作的位置,不过,操作位置需远离监测器。

要分开这两个部分只需松开中间的两个插销,两个插销在测试仪背面附近位置,只需从顶部后侧位置提起插销即可分开。

1/4-20号螺纹接口方便测试仪内顶部位置安装三角支架。

两个支角用在控制部件低部下方,方便提升前面的小格子,这样操作人员更方便地阅读测试读数。

面板正前方的开关有一可选按钮,带有三个不得同时使用的“充电板控制件”。

它们相互为机械互锁,以便一次只能选择一项功能。

控制件必需接地良好。

三个按钮可在“充电板电压”读数下面直接接通,直接显示出测试仪的量程和功能等。

标有“充电板控制”的充电板中央下方设置了三个开关,它将直接决定其充电/放电状态。

高压控制旋钮,“高压通”显示器和与两极有关的“极性”按钮开关,及其初次充静电量“计时器极限”开关可以设置出计时器的初始/终末静电压极限值。

离子风机通用使用规范-A2精选全文

离子风机通用使用规范-A2精选全文

可编辑修改精选全文完整版离子风机通用管理规范1.0 目的:明确离子风机安装要求、正确使用及维护保养方法,使能保持正常的消除静电荷功能。

2.0 范围:适用于本公司所有使用的离子风机、离子风棒、离子风管、离子风蛇。

3.0定义:离子风机可产生大量的带有正负电荷的气流,利用风机把电荷吹到物体的表面,与其中和,达到消除静电的效果。

4.0职责:4.1 生产部4.1.1 负责该部门设备的日常保养并完成离子风机保养记录点检;4.1.2 离子风机异常时异常反馈改善部报修。

4.2货仓部4.2.1 负责该部门设备的日常保养并完成离子风机保养记录点检;4.2.2 离子风机异常时异常反馈改善部报修;4.2.3 对新采购的离子风机及时通知ESD工程师检测合格后方能入库或发放给使用部门。

4.3品管部4.3.1 负责该部门设备的日常保养并完成离子风机保养记录点检;4.3.2 离子风机异常时异常反馈改善部报修;4.3.3 IPQC负责监督各部门使用离子风机的正确使用、日保养、月保养、点检情况并确认签字。

4.4 改善部4.4.1 负责离子风机的样品评估以及认证并完成样品评估认证报告;4.4.2 负责离子风机月度检测并完成离子化设备检测记录表及对现场人员离子风机操作规范宣导;4.4.3 负责离子风机的上线安装、各部门反馈异常的离子风机报修、各部门离子风机月度保养并完成离子风机保养记录表。

4.5 工程部4.5.1负责该部门设备的日常保养并完成离子风机保养记录点检;4.5.2 离子风机异常时异常反馈改善部报修。

4.6 采购部4.6.1 按各部门要求购买可靠的离子风机。

5.0作业内容 5.1说明:5.2安装要求说明:5.2.1 改善部安装前必须确认离子风机性能合格,方可上线安装;5.2.2 安装时必须与使用部门一起确认安装位置,保证离子风机开启后能够有效作用于操作区域(≤70cm ),同时考虑实际使用过程中不可对现场生产操作造成品质/效率影响;5.2.3 主机安装好后,必配置:加强设备接地线+出风口飘带+风量大于80%打胶固定+出风口对准作业区域后打胶定位;5.2.4 安装后走线以不影响现场5S 为原则整理OK 。

宇浩PURESTAT DC-199A使用说明书

宇浩PURESTAT DC-199A使用说明书

PURESTAT DC —199A 使用说明书一 离子风机图片及说明电源开关电源指示灯报警指示灯 MODE 键 DOWN 键 UP 键 风速显示平衡电压显示使用时间显示冷风显示DC24V 电源插座预留 数据线插座接地线插座出风口及感应网进风口灰尘清洁旋扭二产品概述首款采用先进的闭环控制技术能自动检测,调节所需的离子,残余电压直观显示,具有声光报警功能及网络通信功能的新型直流离子风机。

三电源连接:接入电源,打开离子风机电源开关,电源指示灯和显示屏点亮,离子风机进入工作状态,开机时离子风机可能出现声光报警(自动调节离子平衡度),属于正常情况。

四操作说明:一)风速调节:1,按键,风量显示数据加大,同时风量也随之加大;2,按键,风量显示数字减少,同时风量也随之减少;二)模式设置:设置完成后,闪烁五次回到正常工作界面1,正常工作状态下按键,进入离子平衡度补赏值设置选项(离子平衡设置值闪烁),按或键设置离子平衡度补赏值大小(补赏值范围-30—+30);2,在离子平衡度设置选项下,按键,进入IP地址设置选,按和键进行IP地址设置(IP地址设置范围1—64);3,在IP地址设置选项下,按键,进入报警上下限设置,按或键设置报警值(范围-30—+30);4,请所有参数设置完闭,关闭机器,然后同时按下,,开机,离子风机进入禁止设置状态,下次要重新设置,用同样的方法打开,进行设置(建议此项设置仅限于管理员使用)五特点数字显示离子平衡电压;自动调节离子平衡电压;等离子高压异常报警;网络通信连接,系统集成数据话;声光报警,提示使用者及管理人员;送风系统检测;权限管理;六技术参数工作电源:输入1000-240V AC 50/60HZ 输出—DC24V/1A工作电流;电源适配器输出0-1A;有效覆盖:400MM*1200MM;工作温度:-50℃—70℃;机身尺寸:145MM*86**250MM(L*W*H)重量:3KG;平衡电压:0V±10V;中和时间:≤ 2S;测试仪器:ME-268A;测试条件:将测试板放在正对离子风机吹风口300MM处,将风量调节最大,不带过滤网,右1000V至100V,湿度≤ 75RH;测试依据:GJB-1997,IEC61340-5-1;七产品维护本产品长期使用,放电针会积累灰尘,影响产品正常运行,请根据车间防尘等级不同,定期清理,具体清理如下:1)用清洁旋扭转动清理;2)撤下进风口网罩用吹尘抢吹放电针;3)撤下进风口网罩用所配的防静电毛刷进行清理;八应用领域:PCB加工生产;液晶屏组装生产;手机,手提电脑,数码相机组装生产线;各种需要消除经典的场合。

工业防静电设备离子风机

工业防静电设备离子风机
ESD系统看板

9
一站式MES硬件产品
8 使用说明
风扇风速七个单位可调F.01~F.07 清洁时间设置调节H000~H999(单位小时)
整机按键功能锁定 整机按键功能解锁 放电针清洁中
风速、清洁设置转换按钮 手动清洁按钮 电源开关按钮(断电后具有断电记忆功能,再通电后无需按电源开关按钮开机)
4、放电针总成 8、金屬后风窗 12、固定调节螺丝

7
一站式MES硬件产品
6 规格参数
模块 技术参数 显示LED
项目
规格
输入电压 DC24V±5%
离子发生方式 AC放电方式
风扇风量 2.56-4.07m³/min
电压施加方式 高频AC方式/±2200V
离子平衡 ±10V以内(测定距离300㎜)
类别 产品型号 电压输入 离子平衡 电压施加方式

参数 SP-F40AR...... AC110~220V 自动离子平衡 ±10V 高频AC ±2200V
类别 风量(单头) 臭氧浓度 使用环境温度 使用环境湿度
14
参数 2.56-4.07m³/min
≤0.03ppm 0-40℃
操作电压:AC110V/60Hz或AC220V/50Hz
测试电压:±1000V-±100V 环境温度:23℃±2℃
距离
300㎜
600㎜
900㎜

1.0S
2.0S
3.5S

1.5S
3.0S
4.5S

0±10V
0±15V
0±20V

8
一站式MES硬件产品
7 系统架构 网络监控更省力 支持软件进行设定、显示和管理,支持同时监控多台离子风机 可实现无线监控离子风机的运行情况,异常时可迅速查明原因 注:发射器与接收器不在整机出货范围内,需单独购买。

离子风机测试仪中文说明书

离子风机测试仪中文说明书

CPM374产品特性:
l CPM374体积小巧,内部可充电池供电,方便移动使用,也可外接AC电源以长时间 工作
l 仪器所有功能由2个按键操作,所选择的程序显示在屏幕上,非常简单,操作方便 l 附机配备的操作软件可以将测量结果输出电脑,进行分析,同时可远距离遥控操纵
仪器 l 高压产生装置带有限流电阻(1016Ω 以上), 非常安全
TIMER = xx.x s U = -xxxx v
上行表示实时时间, 下行表示实时电压. 当电压衰减到负 100V 时计时停止.
然后开始测试离子平衡度, 屏幕显示: OFFSET = xxx s U = xxxx v
上行表示测试时间, 下行表示离子平衡度(过剩电压), 10 秒种后测试停止.
-7-
注! CPM374 具有自动关机功能,当待机时间超过 10 分钟,自动关闭. CPM374 也可接外 部 220V AC 电源,由外接 AC 电源供电时, 仪器没有自动关机功能。
3.2. 测量模式描述 CPM374 具有 3 个操作模式, 功能如下:
3.2.1. 充电板检测模式(Charge Plate Mode) 该模式用于测试静电消除器的消除静电时间和离子平衡度, 测试示意图如下:
七. 仪器屏幕其他信息显示
八. 产品维护
-2-
一. 产品描述
CPM374由计时器、内置高压产生器、电位探头和电极板构成,可以测量带电物体的电 位和各种静电消除器的散电时间及离子平衡度, 最新 6.10 版 CPM374 有 3 个测量模式可 以选择:
l 充电板检测模式(Charge Plate Mode) l 静电压表模式(Voltmeter Mode) l 场强仪模式(Electrostatic Field Meter Mode)
  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

DR.SCHNEIDER PC
斯莱德SL-001离子风机
使用操作和维护保养
SL-001离子风机是一种消除静电的专用设备。

属TPK离子风机系列的一种。

具有安装简易,工作平稳,消除静电速度快的特点。

第一节:作用原理
SL-001离子风机可产生大量的带有正负电荷的气流,可以将物体上所带的电荷中和掉。

当物体表面所带为负电荷时,它会吸引气流中的正电荷,当物体表面所带为正电荷时,它会吸引气流中的负电荷,从而使物体表面上的静电被中和,达到消除静电的目的。

SL-001离子风机有小风机提供风力,风力大小可由调速开关在一个很大的范围内进行调节。

电离器件:电离器件在高压发生装置产生的低电流高电压作用下,形成一个稳定的高强电场,电离空气形成离子体,由气流带出到达物体表面,达到中和静电的目的。

电离器件上有专用的清洁器,可以清除电离针上的积灰,保持电离器件的正常工作。

SL-001离子风机有专用的离子平衡电路,可以达到离子的自动平衡。

SL-001离子风机的消除静电的功能,可以解决因静电作用引起的生产问题,如解决静电引起的吸尘问题,塑料制品加工时的粘合问题,静电排斥引起的小零件跳跃问题。

第二节:产品特点
1.中和静电迅速。

2.离子气流覆盖面积大。

3.风力调节范围宽。

4.有专门的离子发射器清洁器。

5.电离指示器。

6.风机有良好的接地保护。

第三节:技术参数
使用电压: 220V 50Hz
消耗电流:≤0.2Amp
出风量: 90~190CFM
气流特性: 30cmX70cm覆盖面积
操作温度: 32ºF(0ºC)~122ºF(50ºC)
臭氧量: 0.03PPM (风速调至最小风机前6英寸测)
噪音:最小 50dB
最大 90dB
外箱:铝合金
表面;静电喷涂
尺寸: 600mmX170mmX90mm
离子平衡度:0v±10v
除静电时间:
*离子平衡电压和静电消除时间符合ESD标准,静电消除时间是从测试电压为1000v~100v测得. *测试仪器使用ME268静电综合测试仪.
*测试数据会因周围空气的温湿变化而有差异.
第四节:安全
4.1 安装操作前须读操作说明书.
4.2 操作前必需可靠接地.
4.3 护格板出入口不许插东西.
4.4 易燃易爆的环境下不可操作风机.
4.5 不得擅自进行修理.
第五节:安装:
SL-001离子风机轻便且使用寿命长,“U”形架用螺丝固定在机身侧面,使用时可对好位置后用M6直径的梅花螺丝上好。

如果特别脏的环境使用可选择过滤器安装。

斯莱德离子风机要求220、50HZ为使用电压,风机接地插座应是单相标准,插座有安全接地线。

电源线的接法按下列方式:
褐色——相线兰——中线绿/黄——地线
第六节:操作
顺时针旋动调速器开关到指示灯亮即打开风机,产生离子气流,调大风机风速,可将调速器开关顺时针旋转,调到“关”的位置指示灯灭,表示风机关机。

调节气流方向需调松支架梅花螺丝,倾斜机身调整上下位置,调好后再上紧支架螺丝。

清洁离子发射架,旋转清洗头手柄顺时针方向转到停,再反复转动,直到清洁干净。

SL-001离子风机产生电离风束覆盖目标区域,风束中和静电时间由多种因素所决定,最重要的两个原因,是离子风机的距离和风速。

空气离子不停地相互中和,阳离子、阴离子通过静电相互吸引,形成这些电荷的转移并且重组。

高风速能使它们更远处的中和,风速越大中和静电越快。

使用离子风机进行电子装配时,电离的气流应尽可能覆盖工作区,这样对物体表面的正负电荷才能很好的中和,使其保持中和状态。

第七节:保养
斯莱德离子风机是以常保养低修理为目标的
保养项目:发射头的清洁、离子平衡度的校正、除静电时间校正。

一周内至少对发射头清洁一次,定期对离子平衡度的校正、除静电时间校正,以确保离子风机正常工作。

7.1 发射器的清洁
清洗发射器的发射点,旋转清洗头手柄顺时针方向转到停后松手,再反复转动,直到清洁干净,每周至少一次。

7.2 空气进、出口的清洗
空气入口网和电离出口网应保持清洁以防止阻塞气流,可以用软毛刷清洁或压缩空气清洁。

7.3 离子平衡度测试
用板式负荷监控仪来测量,或用离子测试仪来测量离子平衡度(残余电压)。

7.4 静电消除时间测试
用静电分析仪或负荷监控板测静电消除时间.
7.5 校准
SL-001离子风机,对离子量的输出设计是平稳的、固定的。

由于可能受到电压波动、环境空气干湿度等因素影响会形成离子平衡度的偏移(残余电压)。

偏移量标准:0V±10V。