Brocade光交命令手册

合集下载

BROCADE博科光纤交换机的设置

BROCADE博科光纤交换机的设置

BROCADE博科光纤交换机的设置博科BROCADE交换机的设置博科登录管理模块➢IE:10.77.77.77 admin/password从Web 的Switch View中点Admin button输入user=admin pass=password。

Configuring IPClick the Network tab在配置IP同时,可配置Syslog的IP,用于记录系统的Log(Max支持6个IP记录系统Log)Firmware Download1.Click the Firmware tab.2.Click the Firmware Download radio button.3.Type the host IP address, user name, password, and fullyqualified path to the file name.Configuring a Switch1.Click the Swicth Table2.Switches can be identified by IP address, domain ID, WorldWide Name (WWN), 或通过命名来确定3.domain IDs一般是系统自动分配,但也可人工说明4.在这里可打印系统的配置信息View ReportRebooting the Switch1.Click the Firmware tab2.Click the Fastboot radio button.Configuring Ports(给Port 命名)1.可给每个Ports命名2.可给每个Ports端口设置Speed3.可设置Ports的Enable/Disable4.+Port(通过购买license)+SPFa)Install the Brocade Ports on Demand licensed product.b)+License Keyc)Enable the ports5.可改变Port口的距离(Long Distance)1)Click the Extended Fabric tab.1.在Configure中2.输入Host IP User Name File Name和Password后Apply下载到指定的Server上3.配置文件也可上传Config DownLoad To Switch(相同配置一次,下载后上传就可)下载traceDumpTrace TableZone1.为了方便管理和区分WinZone,UnixZone,将应用分为不同的Zone进行管理(将应用主机HBA卡和存贮的Port口绑在一起,以应用起名Alias)2.一个Alias下放一个应用主机HBA卡联接的Switch上的Port+存贮的一个Port构成一个Zone)Selecting the Zoning Method一般选择Port Zone类型,就是按Port划Zone +Zone➢给新命名的Zone+Add Member(+Port),到命名的Zone中(一般Min是两个Port,一个是存贮的,一个是主机的)➢这样不继的+Zone,到+完为止Create Config并将ZONE加入到CONFIG中把所有的Zone+到一个Config中,启动这个Config就完成了➢将Zone Member + 到这个Config中Save & Enable这CONFIGSwitch级联Enabling Long Distance Fabric Mode➢需要这个Brocade ExtendedFabrics licensese➢这是针对Port设置Long Distance(当然要有相应的License Key)级联1.修改两个交换机的IP和名字2.把两个交换机的域名改为不同。

Brocade光纤交换机常用命令

Brocade光纤交换机常用命令

标签:?2013-12-24 10:19?2062人阅读?(0)???分类:SanIBM的双机双柜,两光纤交换机分别引一根光纤到另一楼光纤交换机,插上无反应,后得知需要更改交换机的domain id 默认出厂为1。

需改为不同号。

下面是博科的交换机命令转。

Brocade SAN交换机常用命令默认用户名:admin,默认密码password1. switchStatusShow查看交换机的总体健康状态switch:admin> switchstatusshowSwitch Health ReportSwitch Name: SWFCRSwitchState: MARGINALDuration: 863:23Power supplies monitor MARGINALTemperatures monitor HEALTHYFans monitor HEALTHYWWN servers monitor HEALTHYStandby CP monitor HEALTHYBlades monitor HEALTHYFlash monitor HEALTHYMarginal ports monitor HEALTHYFaulty ports monitor HEALTHYMissing SFPs monitor HEALTHYAll ports are healthyswitch:admin>2. switchShow查看交换机基本配置信息Enter the switchShow command, which displays the following information for a switch:- switchname - The switch name.- switchtype - The switch model and firmware version numbers.- switchstate - The switch state: Online, Offline, Testing, or Faulty.- switchrole - Displays the switch role: Principal, Subordinate, or Disabled.- switchdomain - Displays the switch Domain ID.- switchid - The embedded port D_ID of the switch.- switchwwn - The switch World Wide Name.13. slotShow查看各个Blade的状态14. portCfgSpeed修改端口的速率15. portEnable或portCfgPersistentEnable4. 重新启用交换机输入命令swichEnable升级FirmwareFC10-6 Blade需要Firmware Version 以上FC4-16IP Blade、FC4-48 Port Blade需要Firmware Version 以上FR4-18i router blade需要Firmware Version 以上如果M48有主备Control Processor,且主备CP处于synchronized状态,则升级过程可在线进行,不干扰数据流量。

BROCADE交换机命令大全

BROCADE交换机命令大全
clihistory Displays a log of most recently executed CLI
commands
cmemretentiontest Data retention test of the central memory SRAMs.
bladeenable Enables all User Ports on a blade.
burninerrclear Clear errors that are stored in the non-volatile
storage
cfgcreate Create a zone configuration
cfgdelete Delete a zone configuration
cfgdisable Disable a zone configuration
bannerset Set security banner
bannershow Display security banner
bcastshow Display broadcast routing information
aptpolicy Get and set Advanced Performance Tuning policy
auditcfg Modifies and displays audit log filter
configuration.
alidelete Delete a zone alias
aliremove Remove a member from a zone alias
alishow Print zone alias information
chassisshow Display all Field Replaceable Units (FRU)

Brocade光交命令手册

Brocade光交命令手册

目录第一章ﻩ管理地址设置ﻩ错误!未定义书签。

1、1ﻩ默认管理地址ﻩ错误!未定义书签。

1、2更改管理地址.............................................................. 错误!未定义书签。

1、3ﻩ查瞧管理地址ﻩ错误!未定义书签。

第二章ZONE基本命令 .......................................................... 错误!未定义书签。

2、1alias命令 ................................................................. 错误!未定义书签。

2、2ﻩzone命令 ................................................................. 错误!未定义书签。

第三章CFG基本命令 ............................................................. 错误!未定义书签。

第四章ﻩ常用维护命令.................................................................. 错误!未定义书签。

4、1 .......................................................................... s witchshowﻩ错误!未定义书签。

4、2ﻩswitchstatusshow......................................................... 错误!未定义书签。

4、3porterrshow错误!未定义书签。

4、4licenseshowﻩ错误!未定义书签。

4、5ﻩsupportshowﻩ错误!未定义书签。

brocade光纤交换机配置简介

brocade光纤交换机配置简介

brocade光纤交换机配置简介安装前准备工作:1.PC或笔记本一台,安装JRE,并设置网卡地址:10.77.77.22,掩码:255.0.0.0;2.PC或笔记本交叉线(1000M网卡可用直通线)连接BROCADE光纤交换机。

配置步骤:1.打开IE界面并在IE地址栏输入:10.77.77.77回车。

弹出如下窗口:用户名:admin密码:password2.设置ZONING。

进行BROCADE主机界面窗口,左上角有一个ZONE ADMIN菜单,如下图红框内所示,单击进入ZONE配置界面。

进行配置界面后,我们需要做如下几步骤以完成ZONE的配置,第一,建ZONE,根据要求将需要添加的端口加入新建的ZONE内,如面几幅图所示:操作顺序:[zone]------[NEW ZONE]------建ZONE名------添加端口-完成第二,完成配置,激活ZONE配置。

建配置名------将需要添加到这个配置的ZONE加入这个配置------点击SAVE CONFIG------最后ENABEL CONFIG 完成。

TELNET添加ZONE步骤网卡设置IP:10.77.77.77 网线连接到BROCADE光纤交换机上开始菜单运行cmd 回车在弹出的CMD窗口中敲入telnet 10.77.77.77 USER:adminPASSWORD:password输入用户名,密码后,按CTRL+C进行:#,如我们需要将交换机的0、1两口做ZONE命令如下:#addzone zone1 (0,0),(0,1)#addconfig cfg1 zone1#save config#enable config完成。

[实用参考]Brocade光交命令手册

[实用参考]Brocade光交命令手册

目录第一章管理地址设置 (2)1.1默认管理地址 (2)1.2更改管理地址 (2)1.3查看管理地址 (2)第二章ZONE基本命令 (3)2.1alias命令 (3)2.2zone命令 (3)第三章CFG基本命令 (5)第四章常用维护命令 (6)4.1switchshow (6)4.2switchstatusshow (7)4.3porterrshow (8)4.4licenseshow (8)4.5supportshow (9)第一章管理地址设置1.1默认管理地址Brocade光交默认管理地址为10.77.77.77 默认用户名密码为admin/password也可以使用串口进行连接,波特率为9600 1.2更改管理地址1.3查看管理地址第二章ZONE基本命令2.1alias命令alias是可选项,对于软zone(wwnzone)来说是非常有必要配置的,它的主要作用就是对每一个wwn或者物理端口取一个别名alicreate"aliName","member[;member...]"如aliadd"aliName","member[;member...]"假设HIS01的HBA0卡坏掉了,这个时候我们换了一块卡,就需要对其成员进行更新,先把新的WWN加进去,如aliremove"aliName","member[;member...]"再比如把原先坏掉的HBA卡的WWN信息从alias里去除,如alidelete"aliName"如果这个成员我们彻底不需要了,例如主机移除,如2.2zone命令zonecreate"zonename","member[;member...]"假设我们需要让HIS01的HBA0能够访问VNG5400_1的SPA和SPB,如和aliadd/aliremove的语法类似,zoneadd/zoneremove也是从一个ZONE里面加入一个成员或者移除一个成员,这里就不具体举例了zonedelete"zonename"假设我们这个时候不需要让HIS01能够访问存储了,我们就删除该Zone,实际上为了达到这个目的,不删除Zone也是可以的,只要让这个Zone不加入到CFG 配置中去就可以了,这里只是为了演示如何删除。

光纤交换机操作手册

光纤交换机操作手册

与交换机交互,可以使用三种方式:串口以太网口光纤口缺省的串口参数是:9600,N,8,1缺省IP访问方式是:IP地址: 10.77.77.77用户名: admin密码:password时区: Pacific time交换机名称:switch可使用ipAddrSet命令来重新设置交换机的IP地址。

在2000和3000系列交换机之中,只能同时支持一个Telnet进程。

Brocade的交换机可以使用命令行和图形界面方式进行管理。

代表性的CLI方法代表性的如:Telnet,HyperTerm和tip。

对于Fabric OS v4.1,SSH v2可以被使用。

如果Brocade Secure Fabric OS被设置有效,CLI 接口必须是Brocade Secure Telnet.Brocade API v2.1提供给用户扩展访问到交换机的方法;可以轻松的整合Brocade SAN Fabric的智能到已经存在的管理应用中,或者快速的开发用户SAN 的特殊功能。

该工具包可以通过Brocade Connect 站点获得。

Brocade Fabric Manager v4.0 是一个实时管理多台Brocade 光纤交换机的很好的一个工具,它提供了有效的配置、监控、动态资源分配管理。

Brocade Web Tool是一个直观简单的管理小型SAN网络的管理工具。

运行支持JRE的Web Browser上。

Brocade 提供基于SNMP的MIBs用来在交换机上读和配置公共设置。

串口管理:n 一条串口连接电缆DB9 (female-to-female)n 使用超级终端或UNIX终端n Windows: Hyper Terminaln UNIX: tipu Microsoft Windows® 环境之中–传输速率: 9600bit/sec–数据位: 8–校验位: None–停止位: 1–流控制: Noneu UNIX® 环境下, 输入以下命令# tip /dev/ttyb –9600u 安装步骤1. 通过串口线将两者进行连接2. 确保交换机已经加电3. 通过ipAddrSet命令设置IP地址(注意: 命令是大小写敏感,但是全大写或全小写也可。

Brocade光交命令手册

Brocade光交命令手册

目录第一章管理地址设置 (2)1.1默认管理地址 (2)1.2更改管理地址 (2)1.3查看管理地址 (2)第二章ZONE基本命令 (3)2.1alias命令 (3)2.2zone命令 (4)第三章CFG基本命令 (5)第四章常用维护命令 (6)4.1switchshow (6)4.2switchstatusshow (7)4.3porterrshow (8)4.4licenseshow (9)4.5supportshow (9)第一章管理地址设置1.1默认管理地址Brocade光交默认管理地址为10.77.77.77 默认用户名密码为admin/password也可以使用串口进行连接,波特率为9600 1.2更改管理地址1.3查看管理地址第二章ZONE基本命令2.1a lias命令alias是可选项,对于软zone(wwn zone)来说是非常有必要配置的,它的主要作用就是对每一个wwn或者物理端口取一个别名alicreate "aliName", "member[; member...]"如aliadd "aliName", "member[; member...]"假设HIS01的HBA0卡坏掉了,这个时候我们换了一块卡,就需要对其成员进行更新,先把新的WWN加进去,如aliremove "aliName", "member[; member...]"再比如把原先坏掉的HBA卡的WWN信息从alias里去除,如alidelete "aliName"如果这个成员我们彻底不需要了,例如主机移除,如2.2z one命令zonecreate "zonename", "member[; member...]"假设我们需要让HIS01的HBA0能够访问VNX5400_1的SPA和SPB,如和aliadd/aliremove的语法类似,zoneadd/zoneremove也是从一个ZONE里面加入一个成员或者移除一个成员,这里就不具体举例了zonedelete "zonename"假设我们这个时候不需要让HIS01能够访问存储了,我们就删除该Zone,实际上为了达到这个目的,不删除Zone也是可以的,只要让这个Zone不加入到CFG 配置中去就可以了,这里只是为了演示如何删除。

BROCADE博科光纤交换机配置文档

BROCADE博科光纤交换机配置文档

博科Brocade 交换机配置与交换机交互,可以使用三种方式:串口以太网口光纤口缺省的串口参数是:9600,N,8,1缺省IP访问方式是:IP地址:10.77.77.77用户名:admin密码:password时区:Pacific time交换机名称:switch可使用ipAddrSet命令来重新设置交换机的IP地址。

在2000和3000系列交换机之中,只能同时支持一个Telnet进程。

Brocade的交换机可以使用命令行和图形界面方式进行管理。

代表性的CLI方法代表性的如:Telnet,HyperTerm 和tip。

对于Fabric OS v4.1,SSH v2可以被使用。

如果Brocade Secure Fabric OS被设置有效,CLI 接口必须是Brocade Secure Telnet.Brocade API v2.1提供给用户扩展访问到交换机的方法;可以轻松的整合Brocade SAN Fabric的智能到已经存在的管理应用中,或者快速的开发用户SAN的特殊功能。

该工具包可以通过Brocade Connect 站点获得。

Brocade Fabric Manager v4.0 是一个实时管理多台Brocade 光纤交换机的很好的一个工具,它提供了有效的配置、监控、动态资源分配管理。

Brocade Web Tool是一个直观简单的管理小型SAN网络的管理工具。

运行支持JRE的Web Browser上。

Brocade 提供基于SNMP的MIBs用来在交换机上读和配置公共设置。

串口管理:⏹一条串口连接电缆DB9 (female-to-female)⏹使用超级终端或UNIX终端⏹Windows: Hyper Terminal⏹UNIX: tip◆Microsoft Windows® 环境之中–传输速率: 9600bit/sec–数据位: 8–校验位: None–停止位: 1–流控制: None◆UNIX® 环境下, 输入以下命令# tip /dev/ttyb –9600◆安装步骤1. 通过串口线将两者进行连接2. 确保交换机已经加电3. 通过ipAddrSet命令设置IP地址(注意: 命令是大小写敏感,但是全大写或全小写也可。

brocade 300光纤交换机用户手册

brocade 300光纤交换机用户手册
文档反馈 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix
介绍 Brocade 300
本章内容 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Brocade 300 功能. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Brocade 300 的端口侧. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Brocade 300 的无端口侧. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 支持的光纤通道网络配置 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Ports on demand 许可证 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 ISL 中继组 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

博科光纤交换机操作手册

博科光纤交换机操作手册

与交换机交互,可以使用三种方式:串口以太网口光纤口缺省的串口参数是:9600,N,8,1缺省IP访问方式是:IP地址: 10.77.77.77用户名: admin密码:password时区: Pacific time交换机名称:switch可使用ipAddrSet命令来重新设置交换机的IP地址。

在2000和3000系列交换机之中,只能同时支持一个Telnet进程。

Brocade的交换机可以使用命令行和图形界面方式进行管理。

代表性的CLI方法代表性的如:Telnet,HyperTerm和tip。

对于Fabric OS v4.1,SSH v2可以被使用。

如果Brocade Secure Fabric OS被设置有效,CLI 接口必须是Brocade Secure Telnet.Brocade API v2.1提供给用户扩展访问到交换机的方法;可以轻松的整合Brocade SAN Fabric的智能到已经存在的管理应用中,或者快速的开发用户SAN 的特殊功能。

该工具包可以通过Brocade Connect 站点获得。

Brocade Fabric Manager v4.0 是一个实时管理多台Brocade 光纤交换机的很好的一个工具,它提供了有效的配置、监控、动态资源分配管理。

Brocade Web Tool是一个直观简单的管理小型SAN网络的管理工具。

运行支持JRE的Web Browser上。

Brocade 提供基于SNMP的MIBs用来在交换机上读和配置公共设置。

串口管理:n 一条串口连接电缆DB9 (female-to-female)n 使用超级终端或UNIX终端n Windows: Hyper Terminaln UNIX: tipu Microsoft Windows® 环境之中–传输速率: 9600bit/sec–数据位: 8–校验位: None–停止位: 1–流控制: Noneu UNIX® 环境下, 输入以下命令# tip /dev/ttyb –9600u 安装步骤1. 通过串口线将两者进行连接2. 确保交换机已经加电3. 通过ipAddrSet命令设置IP地址(注意: 命令是大小写敏感,但是全大写或全小写也可。

博科 光纤交换机配置命令一览

博科 光纤交换机配置命令一览

DS_200B:admin> helpaaaconfig Configure RADIUS for AAA servicesad Specifies all administration domain (AD)-leveloperationsag Configure the Access Gateway featureagshow Displays the Access Gateway information registeredwith the fabricagtcfgdefault Reset SNMP agent to factory defaultaliadd Add a member to a zone aliasalicreate Create a zone aliasalidelete Delete a zone aliasaliremove Remove a member from a zone aliasalishow Print zone alias informationaptpolicy Get and set Advanced Performance Tuning policy auditcfg Modifies and displays audit log filterconfiguration.authutil Get and set authentication configuration backplanetest Backplane connection test for multi-blade systems. backport Test for back-end ASIC pair to ASIC pair links. bannerset Set security bannerbannershow Display security bannerbcastshow Display broadcast routing information bladebeacon Enables or disables blade beaconing or displays thecurrent mode.bladedisable Disables all user ports on a blade.bladeenable Enables all User Ports on a blade.burninerrclear Clear errors that are stored in the non-volatilestorageburninerrshow Display errors that are stored in the non-volatilestorageburninstatus Display the diagnostics burnin status.camtest Verify QuickLoop's Content Addressable Memory(CAM).SID translationcentralmemorytest Test ASIC central memory operation.cfgactvshow Display Effective zone configuration information cfgadd Add a member to a configurationcfgclear Clear all zone configurationscfgcreate Create a zone configurationcfgdelete Delete a zone configurationcfgdisable Disable a zone configurationcfgenable Enable a zone configurationcfgremove Remove a member from a configurationcfgsave Save zone configurations in flashcfgshow Print zone configuration informationcfgsize Print size details of zone databasecfgtransabort Abort zone configuration transaction cfgtransshow Print zone configurations in transaction buffer chassisconfig Display or set the chassis configuration chassisname Display or set the chassis's Namechassisshow Display all Field Replaceable Units (FRU) chipregshow Displays the port registers for a given chipnumber.cmemretentiontest Data retention test of the central memory SRAMs. cmitest Verify CMI bus between ASICs.configdefault Reset config to factory defaultconfigdownload Load switch config from a serverconfigshow Print switch config parametersconfigupload Save switch config to a serverconfigure Set switch config parametersdatatypeshow Display available diagnostic data types.date Print/set the system date and timedbgshow Display debug levels of various modules defzone Activates or deactivates a default zoneconfiguration.diagclearerror Clears diagnostics failure status. diagcommandshow Display diagnostic command descriptions. diagdisablepost Disable diagnostic POST.diagenablepost Enable diagnostic POST.diagenv Diagnostic debug parameters management package. diaghelp Display diagnostic command descriptions. diagloopid Select the diagnostics loop ID.diagmodeshow Displays diagnostic mode configuration. diagpost Displays the contents of port registers andmemories.diagretry Sets diagnostic retry modediagsetburnin Initializes the blade for a burnin run.diagsetcycle Set diagnostic script parameters. diagsetesdmode Set or display ESD mode.diagsetshowtime Set or display diagnostic show-time mode. diagshow Display diagnostic status.diagshowtime Set or display diagnostic show-time mode. diagstatus Display currently running diagnostic tests. diagstopburnin Terminate burnin run on a blade.distribute Distributes data to switches in a fabric.dlsreset Turn off the dynamic load sharing (DLS) option dlsset Turn on the dynamic load sharing (DLS) option dlsshow Display the state of the dynamic load sharingoptiondnsconfig Configure DNS serviceenclosureshow Display the switch enclosure attributes errclear Clear error logerrdelimiterset Sets the error log start and end delimiter formessages sent to the console and syslog errdump Print error log (no page breaks)errfilterset Sets a filter for an error log destination errmoduleshow Displays all the defined modules in the system errshow Print error logfabportshow Display contents of a particular port's data fabretryshow Display retry count of various fabric commands fabriclog Displays or manipulates the fabric log fabricprincipal Displays/Enables/Disables Principal SwitchSelection modefabricshow Print fabric membership infofabstateclear Clears the fabric state information fabstateresize Changes the number of state entries fabstateshow Displays the fabric state information fabstatsshow Displays the fabric statistics information fabswitchshow Display fabric switch state information fandisable Disables a fan unit.fanenable Enables a fan unit.fanshow Print fan statusfastboot Reboot this switch and bypass POST fastwritecfg Configure FC fastwrite featurefazoneadd Add a member to a fabric assist zone fazonecreate Create a fabric assist zonefazonedelete Delete a fabric assist zonefazoneremove Remove a member from a fabric assist zone fazoneshow Print Fabric Assist Zone information fcipchiptest Functional Test of Components in FCIP Complex. fciphelp Print FCIP help infofcippathtest Data Path Test of the FCIP complex.fcping Sends a FC ELS ECHO request to a port fcplogclear Clear the FCP logfcplogdisable Disable logging of FCP eventsfcplogenable Enable logging of FCP eventsfcplogshow Display FCP probing log information fcpprobeshow Display FCP probing information fcprlsshow Display FCP RLS (read link state) information fcrchiptest Functional Test of FCR FPGA.fcrconfigure Sets FC Router configuration parameters. fcrfabricshow Displays FC Routers on a backbone fabric. fcrlsancount Display maximum LSAN zone limit.fcrlsanmatrix Manage LSAN fabric matrix configuration. fcrpathtest Data Path Test on Connection between FCR FPGA andCentral ASIC.fcrphydevshow Displays FC Router physical device information. fcrproxyconfig Displays or configures proxy devices presented byan FC Router.fcrproxydevshow Displays FC Router proxy device information. fcrresourceshow Displays FC Router physical resource usage. fcrrouterportcost Displays FC Router route information.fcrrouteshow Displays FC Router route information. fcrxlateconfig Displays or persistently configures a translate(xlate) domain's domain ID for bothEX_Port-attached fabric and backbone fabric.fddcfg fddcfg manages the fabric data distributionconfiguration parameters.fdmicacheshow Display abbreviated remote FDMI device informationaccording to remote domain IDfdmishow Display detailed FDMI device information ficonclear Clears contents of the specified FICON managementdatabaseficoncupset Sets FICON-CUP parameters for a switch ficoncupshow Displays FICON-CUP parameters for a switch ficonhelp Displays FICON commandsficonshow Displays contents of the specified FICON managementdatabasefiltertest Run frame filter test for bloom ASICs. firmwarecommit Commit firmware to stable storage firmwaredownload Download firmware into switch firmwaredownloadstatus Display the progress and status of firmwareDownload firmwarerestore Restore the old firmware in the switchfirmwareshow Display firmware versions in the switchfosconfig Enable/disable FabOS servicesfporttest Functional test of F->N N->F point to point path. framerpathtest Tests data path between ASICsfrureplace Replace a Field Replacable Unitfspfshow Print FSPF global informationfwalarmsfilterset Configure alarms filtering for Fabric Watch fwalarmsfiltershow Show alarms filtering for Fabric Watchfwclassinit Initialize all Fabric Watch classesfwconfigreload Reload Fabric Watch configurationfwconfigure Configure Fabric Watchfwfrucfg Configure FRU state and notificationfwhelp Print Fabric Watch help infofwmailcfg Configure Fabric Watch Email Alertfwportdetailshow Create a report with detailed port information fwsamshow Show availability monitor informationfwset Set port persistence timefwsettocustom Set boundary & alarm level to custom fwsettodefault Set boundary & alarm level to defaultfwshow Show thresholds monitored and port persistence time grep Linux grep commandh Print shell historyhadisable Disables the High Availability feature in theswitch.hadump Displays information about the status of the HighAvailability feature in the switch.haenable Enables the High Availability feature in the switch hafailover Forces the failover mechanism so that the StandbyControl Processor (CP)becomes the Active CP. hashow Displays control processor (CP) status hasyncstart Enables HA state synchronization.hasyncstop Disables the HA state synchronization.help Print this listhistorylastshow Displays last history recordhistorymode Display or set the mode of the history log historyshow Displays entire history loghttpcfgshow Used to show the version of the Java plug-in usedby the Webtoolsi Display process summaryifmodeset Set the link operating mode for a network interface ifmodeshow Display the link operating mode for a networkinterfaceinterfaceshow Display the FSPF (TM) interface information interopmode Displays/enables/disables Brocade switchinteroperability with switches from othermanufacturersiodreset Turn off the in-order delivery (IOD) optioniodset Turn on the in-order delivery (IOD) optioniodshow Display the state of the in-order delivery option ipaddrset Set ethernet and FC IP addressesipaddrshow Print ethernet and FC IP addressesipfilter Manage/display IP filtersiscsihelp Print iSCSI help infoislshow Display the current connections and statuskilltelnet Terminate telnet/serial login sessionsinteractivelylicenseadd Adds license keys to switchlicensehelp Print license help infolicenseidshow Displays the system license IDlicenseport Configure per-port POD license assignments licenseremove Removes a license key from this system licenseshow Displays current license keyslinkcost Set or print the FSPF cost of a linklogin Login as a new userlogout Logout from remote sessionloopporttest Functional test of L-port M->M path on a loop. lsdbshow Displays the FSPF link state databasememshow Display memory usage in the system.minicycle Functional test of internal and external transmitand receive paths at full speed.minispropshow Displays ASIC pair properties.more Linux more commandmscapabilityshow Display Management Server Capability. msconfigure Configure Management Servermsplatshow Display the Management Server Platform Database msplatshowdbcb Display the Management Server Database ControlBlockmsplcleardb Clear the Management Server Platform Databasefabric-widemsplmgmtactivate Activate the Management Server Platform Databasefabric-widemsplmgmtdeactivate Deactivate the Management Server Platform Databasefabric-widemstddisable Disables the Management Server Topology DiscoveryManagement Servicemstdenable Enables the Management Server Topology DiscoveryManagement Servicemstdreadconfig Display status of Management Server TopologyDiscovery Servicemyid Display the current login session details nbrstateshow Display FSPF (TM) neighbors' states nbrstatsclear Reset the FSPF (TM) interface countersnetstat Display network connections and statisticsnodefind Display all the devices' PID matching the givenworld wide namensaliasshow Display local Name Server information with Aliases nsallshow Print global Name Server information nscamshow Print local Name Server Cache information nsshow Print local Name Server information information nszonemember Display the information of all the online deviceswhich are zoned with the given device. opensource Display information on open source softwareutilized in FabOSpasswd Set usernames and passwordspasswdcfg passwdcfg manages the password policies. pathinfo Display routing information between two ports pdshow Show information from Panic Dump file perfaddeemonitor Add end-to-end monitorperfaddipmonitor Add monitor for IP trafic frame count perfaddreadmonitor Add filter-based monitor - SCSI Read perfaddrwmonitor Add monitor - SCSI Read and Write perfaddscsimonitor Add monitor for SCSI frame count perfaddusermonitor Add filter-based monitorperfaddwritemonitor Add filter-based monitor - SCSI Write perfcfgclear Clear Performance settings from FLASH perfcfgrestore Restore Performance configuration from FLASH perfcfgsave Save Performance configuration to FLASH perfclearalpacrc Clears the CRC error count associated with a portand Arbitrated Loop Physical Address (AL_PA). perfcleareemonitor Clears statistics counters of one or moreend-to-end performance monitors. perfclearfiltermonitor Clears counters of one or more filter-basedperformance monitors.perfdeleemonitor Delete end-to-end monitorperfdelfiltermonitor Delete filter-based monitorperfhelp Print Performance Monitoring help info perfmonitorclear Clear end-to-end/filter-based/ISL monitors perfmonitorshow Show end-to-end/filter-based/ISL monitors perfsetporteemask Set overall mask for end-to-end monitors perfshowalpacrc Get ALPA CRC count by port and ALPA perfshoweemonitor Show user-defined end-to-end monitors perfshowfiltermonitor Show filter-based monitors perfshowporteemask Show the current end-to-end maskpkicreate Creates public key infrastructure (PKI) objects pkiremove Removes existing public key infrastructure (PKI)objectspkishow Displays existing public key infrastructure (PKI)objectspolicy Configure IPSec encryption and authenticationalgorithmsportalpashow Show the ALPAs of a portportbuffershow Print the buffer allocations for the ports of aquadportcamshow Display filter utilizationportcfg Create/Delete a new ip interface/route/arp entry onthe GigE portportcfgdefault Restore the port configuration to defaults portcfgeport Enable/Disable a port from becoming E_Port portcfgexport Sets a port to be an EX_Port and sets and displaysEX_Port configuration parameters. portcfggport Lock a port as a G_Portportcfgislmode Configure a port to be ISL R_RDY Modeenabled/disabledportcfglongdistance Configure a Long Distance Portportcfglport Lock a port as a L_Portportcfgnpivport Enables and disables NPIV functionality on a port. portcfgnport Enable/disable N_Port capability for a port portcfgpersistentdisable Persistently disable a port portcfgpersistentenable Enable a persistently disabled portportcfgshow Displays port configuration settings. portcfgspeed Configure a port to a particular speed level portcfgtrunkport Configure a port for trunkingportcfgvexport Sets a port to be an VEX_Port connected to FC-IPand sets and displays VEX_Port configurationparameters.portcmd Execute commands (ping etc) on the GigE port portdebug Set debug level and verbosity level of port modules portdisable Disable a specified portportenable Enable a specified portporterrshow Print port error summaryportflagsshow Display the port status bitmaps of all ports in aswitchportledtest Cycle user port LEDs.portlogclear Clear port activity logportlogconfigshow Display portlog configurationportlogdisable Disable portlog facilityportlogdump Print port log (no page breaks) portlogdumpport Print port log (no page breaks)portlogenable Enables port log facilityportlogeventshow Display information about port log events portloginshow Display port login informationportlogpdisc Set or clear the debug_pdisc_flagportlogreset Enable portlog facilityportlogresize Resize the port logportlogshow Print port activity logportlogshowport Print port activity logportlogtypedisable Disable port loggingportlogtypeenable Enable port loggingportloopbacktest Functional test of port N->N path.portmirror Set a port's configuration to be disabled orenabledportname Assign or display the name associated with a port portperfshow Print port throughput numbersportregtest Write/read test of the ASIC SRAMs portregtest. portrouteshow Display various routing tables for a portportshow Show configured ip interfaces/routes/arp entries onthe GigE Portportstats64show Display the 64-bit hardware statistics for a port portstatsclear Clear the status of a specified switch port portstatsshow Print hardware statisticsportswap Swaps area numbersportswapdisable Disable portswap featureportswapenable Enable portswap featureportswapshow Display port and area informationporttest Functional test on a live fabric. Starts porttest. porttestshow Retreive information from porttest.portzoneshow Displays the enforced zone type of the F/FL-portsof a switch.powerofflistset sets slot power off list orderpowerofflistshow Displays slot power-off order.psshow Print power supply statusquietmode Displays/enables/disables quietmode on telnetsessionreboot Reboot this processorroutehelp Print routing help infosaschiptest Functional Test of Components in SAS Complex. saspathtest Data Path Test of the SAS complex.secactivesize Displays size of the active (security) database secauthsecret Creates/Manages DHCHAP secret key details seccertutil Creates/Manages/Displays third party PKIcertificatessecdefinesize Displays size of the defined (security) database secfabricshow Displays security related fabric information secfcsfailover Forces primary role to this FCS switch secglobalshow Displays current internal security stateinformationsechelp Displays information about security commands secmodedisable Disables secure modesecmodeenable Enables secure modesecmodeshow Displays whether secure mode is enabled or disabled secnonfcspasswd Sets the admin passwd for non-FCS switches secpolicyabort Aborts changes to defined policysecpolicyactivate Activates all policy setssecpolicyadd Adds members to an existing policysecpolicycreate Creates a new policysecpolicydelete Deletes an existing policysecpolicydump Displays all members of existing policies secpolicyfcsmove Moves a member in the FCS policy secpolicyremove Removes members from an existing policy secpolicysave Saves defined policy set and sends to all switches secpolicyshow Shows members of one or more policies secstatsreset Resets security statisticssecstatsshow Displays security statistics sectemppasswdreset Resets temporary password sectemppasswdset Sets temporary passwordsectransabort Aborts current transactionsecversionreset Resets version stampsensorshow Display sensor readingssetdbg Set debug level of the specified module setesdmode Set or display ESD mode.setmfgmode Set or display diagnostic MFG mode. setmodem Enables or disables modem login to a controlprocessor (CP)setsplbmode Set or display SPLB mode.setverbose Set verbosity level of the specified module sfpshow Print Serial ID SFP information shellflowcontroldisable Disable xon-xoff flow control on console serialportshellflowcontrolenable Enable xon-xoff flow control on console serial port slotpoweroff Removes power from a slot.slotpoweron Restores power to a slot.slotshow Displays the status of all slots in the system. sltest Serial link test of port N->N path.snmpconfig Configure SNMPsnmpmibcapset Set options for configuring SNMP Mib/TrapCapabilitysnmpmibcapshow Show SNMP Mib/Trap Configurationspinfab Functional test of switch to switch ISL cabling andtrunk group operation.spinjitter line-speed jitter measurementspinsilk Functional test of internal and external transmitand receive paths at full speed sramretentiontest Data retention test of the miscellaneous SRAMs inASIC.statsclear Clear port and diagnostic statistics.statstest Statistics counter test for the ASICs.stopporttest Terminate the running porttest.supportffdc Modifies or displays first-failure data capture(FFDC) configuration.supportftp set support Ftp parameterssupportsave retrieve support data from switch to host supportshow Prints switch information for debugging purposes. supportshowcfgdisable Disables a group of commands under supportshowcommand.supportshowcfgenable Enables a group of commands under supportshowcommand.supportshowcfgshow Displays the groups of commands enabled fordisplay. by the supportshow command. switchbeacon Set switch beacon on or off switchcfgpersistentdisable Persistently disable a switch switchcfgpersistentenable Enable a persistently disabled switch switchcfgspeed Configures all ports of the switch to a particularspeed levelswitchcfgtrunk Configure all ports on the switch for trunking switchdisable Disable this switchswitchenable Enable this switchswitchname Print/set this switch's nameswitchreboot Halts and restarts the operational switch. switchshow Print switch and port status switchstatuspolicyset Set policy parameters for overall switch status switchstatuspolicyshow Print policy parameters for overall switch status switchstatusshow Print overall switch statusswitchuptime Display the amount of time for which the switch isupsyslogdfacility Change the syslog facilitysyslogdipadd Add syslog daemon IP address syslogdipremove Remove syslog daemon IP address syslogdipshow Print the syslog daemon targetssysshutdown Provides a graceful shutdown to protect the switchfile systems.systemverification Run a suit of diagnostic tests on all switches in asystem.tempshow Print temperature readingstimeout Set/show the IDLE timeout value for a login session topologyshow Display the unicast fabric topologytracedump generate/remove trace dump or display trace dumpstatustrackchangeshelp Print Track Changes help infotrackchangesset Configure alert for login/logout/config update trackchangesshow Displays status of track changestrunkdebug Debug a trunk link failuretrunkshow Display trunking informationtsclockserver Displays or sets the NTP server addresststimezone Displays or sets the time zoneturboramtest Turbo SRAM test for bloom ASICs.txdpath Functional test of ASIC pair TXA TXD connections. uptime Print how long switch has been upurouteconfig Configure a static routeurouteremove Remove a static routeurouteshow Display unicast routing informationuserconfig Display or configure user accountsuserrename Rename user login nameversion Print firmware versionwwn Display or set the world wide namezone Copies/Removes/Validates zone objectszoneadd Add a member to a zonezonecreate Create a zonezonedelete Delete a zonezonehelp Print zoning help infozoneobjectcopy Copies a zone objectzoneobjectexpunge Expunges a zone objectzoneobjectrename Rename a zoning Objectzoneremove Remove a member from a zonezoneshow Print zone information。

Brocade光纤交换机常用命令

Brocade光纤交换机常用命令

Brocade光纤交换机常用命令IBM的双机双柜,两光纤交换机分别引一根光纤到另一楼光纤交换机,插上无反应,后得知需要更改交换机的domain id 默认出厂为1。

需改为不同号。

接下来是小编为大家收集的Brocade 光纤交换机常用命令,希望能帮到大家。

Brocade 光纤交换机常用命令使用电脑连接管理网口,默认IP地址为:192.168.0.1,掩码:255.255.255.0默认用户名:admin,默认密码password1. switchStatusShow查看交换机的总体健康状态2. switchShow查看交换机基本配置信息3. portShow 查看端口状态4. fanShow查看交换机散热风扇的状态5. psShow查看交换机的电源状态注:如果安装FR4-18i、FC4-16IP、FC10-6、FC8-48板,需要满配4个电源6. tempShow查看交换机的环境温度查看交换机的内部消息日志8. supportShow、supportSave、pdShow 收集交换机的诊断数据检查连接到交换机的设备10. licenseShow、wwn检查license文件和交换机的WWN号11. version检查Fabric OS的版本,将显示如下信息:12. haShow查看Control Blade的状态查看各个Blade的状态14. portCfgSpeed修改端口的速率15. portEnable或portCfgPersistentEnableReset端口16. 检查WWN卡状态下列命令如果不能正确执行,则说明WWN卡需要更换:www,chassisShow:显示交换机的WWN号chassisShow:显示chassis和WWN卡的状态ipAddrShow,ipAddrSet:显示CP Blades的IP地址historyShow、historyLastShow:显示历史日志信息switchName:显示交换机的名字修改Domain ID1. 查看当前的Domain ID输入命令fabricShow,输出结果中的Switch ID即包括交换机的Domain ID。

Brocade光交命令手册

Brocade光交命令手册

Brocade光交命令手册目录第一章管理地址设置 (3)1.1默认管理地址31.2更改管理地址31.3查看管理地址3第二章ZONE基本命令 (5)2.1alias命令52.2zone命令6第三章CFG基本命令 (8)第四章常用维护命令 (9)4.1 ............................ switchshow94.2 ......................... switchstatusshow124.3 ............................ porterrshow134.4 ............................ licenseshow134.5 ............................ s upportshow14第一章管理地址设置1.1默认管理地址Brocade光交默认管理地址为10.77.77.77 默认用户名密码为admin/password也可以使用串口进行连接,波特率为9600 1.2更改管理地址1.3查看管理地址第二章ZONE基本命令2.1a lias命令alias是可选项,对于软zone(wwn zone)来说是非常有必要配置的,它的主要作用就是对每一个wwn或者物理端口取一个别名alicreate "aliName", "member[; member...]"如aliadd "aliName", "member[; member...]"假设HIS01的HBA0卡坏掉了,这个时候我们换了一块卡,就需要对其成员进行更新,先把新的WWN加进去,如aliremove "aliName", "member[; member...]"再比如把原先坏掉的HBA卡的WWN信息从alias里去除,如alidelete "aliName"如果这个成员我们彻底不需要了,例如主机移除,如2.2z one命令zonecreate "zonename", "member[; member...]"假设我们需要让HIS01的HBA0能够访问VNX5400_1的SPA和SPB,如和aliadd/aliremove的语法类似,zoneadd/zoneremove也是从一个ZONE里面加入一个成员或者移除一个成员,这里就不具体举例了zonedelete "zonename"假设我们这个时候不需要让HIS01能够访问存储了,我们就删除该Zone,实际上为了达到这个目的,不删除Zone也是可以的,只要让这个Zone不加入到CFG 配置中去就可以了,这里只是为了演示如何删除。

brocade 300光纤交换机用户手册

brocade 300光纤交换机用户手册

53-1001020-012008 年 3 月 12 日Brocade 300硬件参考手册支持 Brocade 300版权所有 © 2008 Brocade Communications Systems, Inc. 保留所有权利。

Brocade 、Fabric OS 、File Lifecycle Manager 、MyView 和 StorageX 是 Brocade Communications Systems, Inc. 在美国和/或其他国家或地区的注册商标,Brocade B-wing 符号、DCX 和 SAN Health 是 Brocade Communications Systems, Inc. 在美国和/或其他国家或地区的商标。

所有其他商标、产品或服务名称均是或可能是其各自所有者用以标识其产品或服务的商标或服务标记。

注意:本文档仅供提供信息之用,不构成涉及设备、设备功能以及已经由或即将由 Brocade 提供的服务的任何明示或暗示的担保。

Brocade 有权随时更改本文档内容,若有更改,恕不另行通知,且不承担与使用本文档有关的任何责任。

本说明性文档中描述的某些功能当前可能不可用。

有关功能和产品可用性的信息,请联系 Brocade 营业部。

本文档中技术数据的出口可能需要美国政府授予的出口许可证。

本文档的作者和 Brocade Communications Systems, Inc. 对因本文档或随附计算机程序中所含信息而导致的任何损失、成本消耗、责任或损坏的任何个人或实体不承担任何义务或责任。

本文档所述产品可能包含受“GNU 通用公共许可证”或其他开源许可证协议保护的“开源”软件。

要查找 Brocade 产品中包含哪些开源软件、查看适用于开源软件的授权条款、获取编程源代码的副本,请访问 /support/oscd 。

Brocade Communications Systems, Incorporated文档历史公司总部Brocade Communications Systems, Inc.1745 Technology DriveSan Jose, CA 95110电话:1-408-333-8000传真:1-408-333-8101电子邮件:info@亚太总部Brocade Communications Singapore Pte. Ltd.9 Raffles Place #59-02 Republic Plaza 1Singapore 048619电话:+65-6538-4700传真:+65-6538-0302电子邮件:apac-info@欧洲和拉丁美洲总部Brocade Communications Switzerland SàrlCentre SwissairTour A - 2ème étage29, Route de l'AéroportCase Postale 105CH-1215 Genève 15瑞士电话:+41 22 799 56 40传真:+41 22 799 56 41电子邮件:emea-info@ 标题出版号更改摘要日期Brocade 300 硬件参考手册53-1001020-01新文档2008 年 3 月 12 日目录关于本文档本文档的结构 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v支持的硬件和软件 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .vi文档约定 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .vi附加信息 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii获取技术帮助 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .viii文档反馈 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ix 第 1 章介绍 Brocade 300本章内容 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1Brocade 300 功能. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1Brocade 300 的端口侧. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2Brocade 300 的无端口侧. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2支持的光纤通道网络配置 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3Ports on demand 许可证 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3ISL 中继组. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4第 2 章安装和配置 Brocade 300本章内容 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5Brocade 300 包含的物件. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5安装和安全注意事项 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6电气注意事项 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6环境注意事项 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6机柜注意事项 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7安装所需使用的项目 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7安装独立的 Brocade 300. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8将 Brocade 300 安装到 EIA 机柜中 . . . . . . . . . . . . . . . . . . . . . . . . . .8电缆管理建议 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9配置 Brocade 300. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10使用 EZSwitch Setup(可选). . . . . . . . . . . . . . . . . . . . . . . . . .10为交换机供电 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10建立串行连接 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11设置交换机 IP 地址. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12设置日期和时间 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 Brocade 300 硬件参考手册iii 53-1001020-01iv Brocade 300 硬件参考手册53-1001020-01第 3 章操作 Brocade 300本章内容 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17对 Brocade 300 加电和断电 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17解释 LED 指示灯的活动. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17LED 指示灯的位置. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18LED 指示灯模式 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19电源状态 LED 指示灯模式 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19系统状态 LED 指示灯模式 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19端口 LED 指示灯模式 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20Ethernet (以太网)LED 指示灯模式 . . . . . . . . . . . . . . . . . . .21POST 和启动说明 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21POST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21启动 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21解释开机自检 (POST) 结果 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22Brocade 300 FRU 单元. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22维护 Brocade 300. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23安装 SFP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23诊断测试 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24管理 Brocade 300. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25附录 A 产品规格本附录内容 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27重量和物理尺寸 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27内存规格 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27设施要求 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28数据传输范围 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28环境要求 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29Fibre Channel 端口规格. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30串行端口规格 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30电源规格 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30支持的 SFP 和 HBA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30系统规格 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31法规符合性 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33FCC 警告(仅美国). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33MIC 声明(韩国). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33VCCI 声明(日本) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33电源线(日本 Denan ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34CE 声明. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34加拿大规定 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34激光符合性 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34RTC 电池. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35电气安全 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35规程证书 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36索引关于本文档本文档旨在供有网络、Fibre Channel(光纤通道)和存储区域网络 (SAN) 技术经验的系统管理员和技术人员使用。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

目录
第一章管理地址设置 (2)
1.1默认管理地址 (2)
1.2更改管理地址 (2)
1.3查看管理地址 (2)
第二章ZONE基本命令 (3)
2.1alias命令 (3)
2.2zone命令 (3)
第三章CFG基本命令 (5)
第四章常用维护命令 (6)
4.1switchshow (6)
4.2switchstatusshow (8)
4.3porterrshow (8)
4.4licenseshow (9)
4.5supportshow (10)
第一章管理地址设置1.1默认管理地址
Brocade光交默认管理地址为10.77.77.77 默认用户名密码为admin/password
也可以使用串口进行连接,波特率为9600 1.2更改管理地址
1.3查看管理地址
第二章ZONE基本命令
2.1alias命令
alias是可选项,对于软zone(wwn zone)来说是非常有必要配置的,它的主要作用就是对每一个wwn或者物理端口取一个别名
alicreate "aliName", "member[; member...]"

aliadd "aliName", "member[; member...]"
假设HIS01的HBA0卡坏掉了,这个时候我们换了一块卡,就需要对其成员进行更新,先把新的WWN加进去,如
aliremove "aliName", "member[; member...]"
再比如把原先坏掉的HBA卡的WWN信息从alias里去除,如
alidelete "aliName"
如果这个成员我们彻底不需要了,例如主机移除,如
2.2zone命令
zonecreate "zonename", "member[; member...]"
假设我们需要让HIS01的HBA0能够访问VNX5400_1的SPA和SPB,如
和aliadd/aliremove的语法类似,zoneadd/zoneremove也是从一个ZONE里面加入一个成员或者移除一个成员,这里就不具体举例了
zonedelete "zonename"
假设我们这个时候不需要让HIS01能够访问存储了,我们就删除该Zone,实际上为了达到这个目的,不删除Zone也是可以的,只要让这个Zone不加入到CFG 配置中去就可以了,这里只是为了演示如何删除。

另外多提一点,删除的Zone 也必须从CFG中remove掉(cfgremove,如果已经加入到CFG中)
第三章CFG基本命令
cfgcreate "cfgName", "member[; member]"
创建一个CFG,把ZONE加入进来,注意,1台交换机或者说1个Fabric(交换机级联的时候),当前只能有一个CFG生效,可以允许有多个CFG配置存在(一般也只建一个)
cfgadd "cfgName", "member[; member]"
再把其他需要生效的Zone加进来
cfgremove "cfgName, "member[; member...]"
如果发现加错了,也可以移除
(cfgsave)
cfgenable "cfgName"
CFG创建完成后或者进行修改后,保存并生效
第四章常用维护命令
4.1switchname
4.2switchshow
查看光交基本信息,一般较多的用来看每个端口的设备连接WWN号
DS_300B_1:admin> switchshow
switchName: DS_300B_1
switchType: 71.2
switchState: Online
switchMode: Native
switchRole: Principal
switchDomain: 1
switchId: fffc01
switchWwn: 10:00:50:eb:1a:ec:26:bd
zoning: ON (CFG)
switchBeacon: OFF
Index Port Address Media Speed State Proto
==============================================
0 0 010000 id N8 Online FC F-Port 50:06:01:60:09:60:12:fd
1 1 010100 id N8 Online FC F-Port 50:06:01:68:09:60:12:fd
2 2 010200 id N8 Online FC F-Port 50:06:01:60:09:60:18:30
3 3 010300 id N8 Online FC F-Port
50:06:01:68:09:60:18:30
4 4 010400 id N8 Online FC F-Port 21:00:00:24:ff:91:4a:4a
5 5 010500 id N8 Online FC F-Port 21:00:00:24:ff:91:4a:4b
6 6 010600 id N8 Online FC F-Port 21:00:00:24:ff:91:4d:74
7 7 010700 id N8 Online FC F-Port 21:00:00:24:ff:91:4d:75
8 8 010800 id N8 Online FC F-Port 21:00:00:24:ff:09:c4:29
9 9 010900 id N8 Online FC F-Port 21:00:00:24:ff:09:c4:44
10 10 010a00 id N8 Online FC F-Port 21:00:00:24:ff:11:76:39
11 11 010b00 id N8 Online FC F-Port 21:00:00:24:ff:11:6b:06
12 12 010c00 id N8 Online FC F-Port 21:00:00:24:ff:11:6a:5d
13 13 010d00 id N8 Online FC F-Port 21:00:00:24:ff:11:6a:e5
14 14 010e00 id N8 Online FC F-Port 21:00:00:24:ff:09:c4:32
15 15 010f00 id N8 Online FC F-Port 21:00:00:24:ff:11:6b:09
16 16 011000 id N8 No_Light FC
17 17 011100 id N8 No_Light FC
18 18 011200 id N8 No_Light FC
19 19 011300 id N8 No_Light FC
4.3switchstatusshow
一般用来检查交换机的健康状态,包括电源、风扇、温度等
4.4porterrshow
用来查看光交端口是否有报错,是链路故障诊断中极为重要的命令重点关注crc err、disc c3、link fail、enc out参数
其中enc out参数一般有值是正常的,因为每次服务器重启或者光纤拔插都会引起数值增长,但是如果在正常运行时,值一直是上涨的,一般都是模块或者线有问题。

其它参数像crc err和disk c3一般100以内可以接受,到几k或者几m 的话是一定要换光纤线(偶尔也有模块坏掉的情况,一般都是劣质光纤线造成的,OM1的或者是假冒的OM3光纤)
statsclear
清零计算器
4.5licenseshow
licenseidshow
查看光交日志
4.6chassisshow
DS_300B_1:admin> chassisshow
POWER SUPPLY Unit: 1
Time Awake: 70 days
FAN Unit: 1
Time Awake: 70 days
FAN Unit: 2
Time Awake: 70 days
FAN Unit: 3
Time Awake: 70 days
CHASSIS/WWN Unit: 1
Header Version: 2
Factory Part Num: 40-1000165-14
Factory Serial Num: ALJ1947L0BD
Manufacture: Day: 21 Month: 9 Year: 2015 Update: Day: 10 Month: 4 Year: 2016 Time Alive: 70 days
Time Awake: 70 days
ID: EMC0000CA
Part Num: CONTRX0000300
Serial Num: BRCALJ1947L0BD
..
4.7supportshow
收集系统日志,这里不贴出来了
.下载可编辑.。

相关文档
最新文档