申龙电梯故障表
三菱电梯故障代码
三菱电梯故障代码7seg31.逆变器2.整流器4.电源5.继电器6.继电器7.安全回路8.门9.井道a.曳引系统b.速度c.称d.dre.系统设定f.通信7seg20.est1.sfs2.nfs3.nrs4.alt逆变器1101(硬件过流)105(e1板门回路异常)10d(过负荷运行)10f(meld过负荷)111(inv保护回路动作)112(ipc清除命令)118(散热器温度异常)11d(过负荷走行)11f(手动过负荷)128(散热器温度异常)12d(过负荷运行)12e(过负荷运行)131(dc-ct故障)132(电流检测零点飘移故障)138(散热器温度异常)13d(过负荷运转(再造电阻))13e(过负荷运转)202(cnv充电异常)204(cnv过电压)211(cnv电压过低)231(充电完了)233(电池完了异常检查)235(cnv低电压)411(e1板电源异常)413(12v电源异常)441(ram备份开始)511(#5off异常)512(#5强制性off异常)513(#lboff异常)514(#lb强制性off异常)515(#bk1on异常)516(#bk1off异常)517(#bk1强制性off异常)518(#bk2on异常)519(#bk2off异常)51a(#bk2强制性off异常)51b(#5on异常)51c (#lbon异常)531(#5on故障)532(#5off故障)533(#5强制性off故障)534(#lbon故障)535(#lboff故障)536(#lb强制性off故障)537(#bk1on故障)538(#bk1off故障)539(#bk1强制性off故障)53a(#bk2on故障)53b(#bk2off故障)53c(#bk2强制性off故障)53d(#rlon故障)53e(#rloff故障)541(#5on故障)542(#lbon故障)543(#bk1on故障)545(#rlon故障)546(#rloff故障)611(60或60a故障)631(hdrnon故障)632(hdrnoff故障)633(控制柜ssuon故障)634(控制柜ssdon故障)635(轿顶(前)ssuon故障)636(轿顶(前)ssdon故障)637(轿顶(后)ssuon故障)638(轿顶(后)ssdon故障)708(维保自动低速操作方式)711(驱动软件异常)712(管理软件异常)713(est动作2次)718(抱闸力矩调整区间暂停)719(维保sfs测试)71f(#29安全电路)731(#89电路断裂)732(dr两端无法重启动)733(e-stop一次)734(e-stop两次)735(管理无法再再生制动)736(启程异常)739(修理运转nrs)743(e-stop一次)74d(安全电路登位指令)74e(管理s/w)74f(群管理s/w)811(运行中开门)812(开门运行(slc))823(41dgoff故障)824(前门cltoff故障)825(后门cltoff故障)826(前门sdeoff故障)827(后门sdeoff故障)831(41dgon异常)832(前门oltoff故障)833(后门oltoff故障)841(前门ds进门验出(en81))842(前门clton故障)843(前门cltoff故障)844(后门clton故障)845(后门cltoff故障)846(前门fgon故障)847(前门fgoff故障)848(后门fgon故障)849(后门fgoff故障)84a(前门olton故障)84b(前门oltoff 故障)84c(后门olton故障)84d(后门oltoff故障)913(tsd开关故障)914(前门rluoff故障)915(前门rldoff故障)916(后门rluoff故障)917(后门rldoff故障)91d(ul/dl都动作)91e(下行dl开关动作)91f (上行ul开关动作)931(前门dzuon故障)932(前门dzdon故障)933(前门rluon故障)934(前门rldon故障)935(后门dzuon故障)936(后门dzdon故障)937(后门rluon故障)938(后门rldon故障)93b(dz检测电路on/off故障)93c(前门平层控制器异常)93d(后门平层控制器异常)93e(usr/dsr都动作)93f(ul/dl都动作)94c (层楼计数异常)a18(#bk1强迫off)a1a(#bk2强迫off)a21(电机温度异常)a22(制动器异常)a31(电机温度异常)a32(制动器异常)a3d(磁极未学习)a3e(pmz相异常)b01(过低速)b02(过高速)b03(顺行)b04(钢丝绳爆胎)b05(编码器偏差)b07(再平层异常)b08(曳引机万萨县)b0d(slc急停)b0e(slc过高速)b0f(slc减速)b11(过低速)。
LEHY_II故障查询表
LEHY_II故障查询表LEHY-II(无能量反馈,C 语言)电梯状态和大分类故障E0--无故障E1--逆变侧E2--整流侧E3--整流侧E4--电源E5--控制屏E6--控制屏E7--外部安全回路E8--门E9--升降开关EA--抱闸曳引机EB--速度控制选层器EC--秤ED--P1 基板EE--系统设置EF--通讯故障LEHY-II (无能量反馈,C 语言)小分类故障1—逆变器7SEG3 7SEG2 7SEG1101--硬件过流SS_IOC105--E1 板门回路异常SS_GDF10D--过负荷运行SD_OCR10F--MELD 过负荷SD_SLIT111--INV保护回路动作SS_LFO112--IPC 清除命令SY_DESTR118--散热器温度异常SW_FTHM211D--过负荷走行SW_SOCR11F--手动过负荷SD_HRT128--散热器温度异常SW_FTHM212D--过负荷运行SW_SOLR12E--过负荷运行SW_SOCR131--DC-CT 故障SD_CTER132--电流检测零点漂移故障SD_CVEE138--散热器温度异常SW_FTHM213D--过负荷运行(再生电阻) SD_OLR13E--过负荷运行SD_OCR2—整流器202--CNV 充电异常SW_CVER204--CNV 过电压SS_COV211--CNV 电压过低SS_CLV231--充电完了SW_CHGLT233--充电完了异常检查SW_CVCK 235--CNV 低电压SW_DCLV 4—电源411--E1 板电源异常SS_PWF413--12V 电源异常SS_P12VF441--RAM 备份开始ST_RAMBAK5—继电器511--#5 OFF 异常SW_CF5B512--#5 强制OFF 异常SW_CF5N513--#LB OFF 异常SW_CFLBB514--#LB 强制OFF 异常SW_CFLBN 515--#BK1 ON 异常SW_CFBK1A516--#BK1 OFF 异常SW_CFBK1B517--#BK1 强制OFF 异常SW_CFBK1N 518--#BK2 ON 异常SW_CFBK2A519--#BK2 OFF 异常SW_CFBK2B51A--#BK2 强制OFF 异常SW_CFBK2N 51B--#5 ON 异常SW_CF5A51C--#LB ON 异常SW_CFLBA531--#5 ON 故障SW_DF5A532--#5 OFF 故障SW_DF5B533--#5强制 OFF 故障SW_DF5N534--#LB ON 故障SW_DFLBA535--#LB OFF 故障SW_DFLBB536--#LB 强制OFF 故障SW_DFLBN537--#BK1 ON 故障SW_DFBK1A538--#BK1 OFF 故障SW_DFBK1B539--#BK1 强制 OFF 故障SW_DFBK1N53A--#BK2 ON 故障SW_DFBK2A53B--#BK2 OFF 故障SW_DFBK2B53C--#BK2 强制 OFF 故障SW_DFBK2N53D--#RL ON 故障SW_DFRLA53E--#RL OFF 故障SW_DFRLB6—继电器611--60 或60A 故障SW_60E631--HDRN ON 故障SW_HDRNA632--HDRN OFF 故障SW_HDRNB633--控制柜 SSU ON 故障SW_SSUA634--控制柜 SSD ON 故障SW_SSDA635--轿顶(前) SSU ON 故障SW_FSSUC1A636--轿顶(前) SSD ON故障SW_FSSDC1A 637--轿顶(后) SSU ON故障SW_RSSUC1A 638--轿顶(后) SSD ON故障SW_RSSDC1A 7—安全回路708--维保自动低速操作 LAMD_TEST711--驱动软件异常SD_32GQ712--管理软件异常SC_S29713-- EST 动作2次SW_EST718--抱闸力矩调整区间停止SP_BKZN 719--维保SFS 测试SFS_TEST71F-- #29 安全电路SN_29731-- #89 回路断开SW_D89732-- DR 侧不能重启动SD_DNRS733-- E-STOP1次SW_EST1734-- E-STOP2 次SW_EST2735--管理不能再启动SC_NRSLRQ736--出发异常SW_NDPD739--维修运行NRS MNT_NRS743-- E-STOP1 次SW_EST174D--安全回路复位指令SY_SFRST74E--管理S/W SC_MSALT74F--群管理S/W SC_GCALT8—门811--运行中开门SW_DOPN812--开门运行(SLC) SS_DKC823--41DG OFF 故障SW_41DGB824--前门CLT OFF 故障SW_FCLT12B825--后门CLT OFF 故障SW_RCLT12B826--前门SDE OFF 故障SW_FSDE12B827--后门SDE OFF 故障SW_RSDE12B831--41DG ON 异常SW_41DGA832--前门OLT OFF 故障SW_FOLT12B833--后门OLT OFF 故障SW_ROLT12B841--层站DS 开门检出(EN81)SW_DSOPN 842--前门CLT ON 故障SW_DFCLT12A843--前门CLT OFF 故障SW_DFCLT12B 844--后门CLT ON 故障SW_DRCLT12A845--后门CLT OFF 故障SW_DRCLT12B 846--前门FG ON 故障SW_DFFG12A847=--前门FG OFF 故障SW_DFFG12B848--后门FG ON 故障SW_DRFG12A849--后门FG OFF 故障SW_DRFG12B84A--前门OLT ON 故障SW_DFOLT12A84B--前门OLT OFF 故障SW_DFOLT12B84C--后门OLT ON 故障SW_DROLT12A84D--后门 OLT OFF 故障SW_DROLT12B 9—井道913--TSD 开关故障SW_TS3SE914--前门RLU OFF 故障SW_FRLUB915--前门RLD OFF 故障SW_FRLDB916--后门RLU OFF 故障SW_RRLUB917--后门RLD OFF 故障SW_RRLDB91D--UL/DL 都动作SW_UDLB91E--下行DL 开关动作SW_DLC91F--上行UL 开关动作SW_ULC931--前门DZU ON 故障SW_FDZUA932--前门DZD ON 故障SW_FDZDA933--前门RLU ON 故障SW_FRLUA934--前门RLD ON 故障SW_FRLDA935--后门DZU ON 故障SW_RDZUA936--后门DZD ON 故障SW_RDZDA937--后门RLU ON 故障SW_RRLUA938--后门RLD ON 故障SW_RRLDA93B--DZ 检测电路ON/OFF 故障SW_DZCCAB 93C--前门平层开关异常SW_FDZRLX93D--后门平层开关异常SW_RDZRLX93E--USR/DSR 都动作SW_UDSRB 93F--UL/DL 都动作SW_UDLB94C--层楼计数异常SW_FMCTE A—曳引系统A18--#BK1 强迫OFF SW_CFBK1N A1A--#BK2 强迫OFFSW_CFBK2N A21--电机温度异常SW_MTHMA22--制动器异常SW_BKERA31--电机温度异常SW_MTHMA32--制动器异常SW_BKERA3D--磁极未学习SD_THNGA3E--PM Z 相异常SD_AZER B—速度B01--过低速SW_TGBLB02--过高速SW_TGBHB03--逆行SW_TGBRB04--钢丝绳打滑SW_ASTB05--编码器偏差SW_TGBXB07--再平层异常SW_TGRLB08--曳引机堵转SW_ASTWB0D--SLC急停SS_DESTB0E--SLC过高速SS_TGBHB0F--SLC 失速SS_ASTB11--过低速SW_TGBLB12--速度与图形偏差故障SD_PVJPB13--减速时限SW_DECTB14--行程过头SW_LOVRB18--手动过高速SW_LOSB21--再平层时限SW_RLTB23--减速时限(缓停止) SW_DECTNB31--速度与图形比较(16 次)SD_OVJP B32--运行检测ST_LSA B33--选层器故障SW_SELDB34--TSD 运行SW_TSAKB35--钢丝绳打滑SW_ASTB37--再平层异常SW_TGRLB38--FMS 失败SW_FMSERB42--选层器偏差警告ST_SLZQB43--选层器偏差故障ST_SELZB46--TLP 行走检出ST_TLPRNC—称C21--运行中秤异常SW_WGE2C23--秤装置断线SW_WGCNC31--运行中秤异常SW_WGE2C32--停止中秤异常SW_WGE1C33--秤装置断线SW_WGCNC34--秤设定异常SW_WGWED-DRD01--SLC急停SS_DESTD02--SLC过高速SS_TGBHD03--SLC 失速SS_ASTD11--SLC开门运行SS_DKCD12--SLC TSD 异常SS_TSDNGD13--DR D5 指令SS_DR_D5D14--DR D89 指令SS_DR_D89D1B--CC_WDT5 次SS_CCWC5D1C--CC_WDT4 次SS_CCWC4D31--DR WDT 故障SD_MCPWDED3D--CC_WDT3 次SS_CCWC3D41--DR WDT 屏蔽定时器动作SS_MCPT10S D4A--CC_WDT 屏蔽定时器动作SS_CCT10S D4E--CC_WDT2 次SS_CCWC2 D4F--CC_WDT1 次SS_CCWC1E—系统设定E32--驱动RAM 故障SD_RAMERE33--驱动系统设定故障SD_DTERE35--ACC 代码设定故障SW_ASYSER E36--曳引机设定故障SW_TSYERE37--速度设定故障SW_SSYERE39--控制RAM 故障SW_RAMER F—通信F31--P1CL 故障SW_STER_P1CLF34--SC 故障SW_STER_ASC1F35--前门CS 故障SW_STER_FCS1 F36--前门DC 故障SW_STER_FDC1 F37--后门CS 故障SW_STER_RCS1 F38--后门DC 故障SW_STER_RDC1 F39--秤故障SW_STER_WGDF3A--前门BC1 故障SW_STER_FCS2 F3B--后门BC1 故障SW_STER_FDC2 F3C--前门IC 故障SW_STER_RCS2 F3D--后门 IC 故障SW_STER_RDC2 F41--P1CL 故障SW_P1CL_HNGF44--SC 故障SW_ASC1_HNGF45--前门CS 故障SW_FCS1_HNGF46--前门DC 故障SW_FDC1_HNGF47--后门CS 故障SW_RCS1_HNGF48--后门DC 故障SW_RDC1_HNGF51--HS 故障SW_HSALL_DOWN_HNG F52--前门IC 故障SW_FIC1_HNG F53--后门 IC 故障SW_FIC5_HNG F54--前门 BC1 故障SW_FBC1_HNG F55--前门BC2 故障SW_FBC2_HNG F56--前门BC3 故障SW_FBC3_HNG F57--前门 BC4 故障SW_FBC4_HNG F58--后门BC1 故障SW_RBC1_HNG F59--后门BC2 故障SW_RBC2_HNG F5A--后门BC3 故障SW_RBC3_HNG F5B--后门BC4 故障SW_RBC4_HNG。
申龙扶梯故障详细说明
申龙扶梯故障详细说明本文整理了一份有关申龙扶梯故障的显示对照表,安全回路说明及故障代码表。
1、故障显示对照表1—左曳引链安全开关指示灯, 2—右曳引链安全开关指示灯,3—下左出入口安全指示灯, 4—下左梳齿板异常安全开关指示灯, 5—左扶手带测速装置指示灯,6—下左围裙板安全指示灯, 7—下梯级下陷安全开关指示灯, 8—下右围裙板安全开关指示灯, 9—右扶手带测速装置指示灯, 10—下右梳齿异常安全开关指示灯, 11—下右出入口安全开关指示灯,12—上梯级下陷安全开关指示灯,13—上左围裙板安全开关指示灯,14—上左梳齿异常安全开关指示灯,15—上左出入口安全开关指示灯,16—断链安全开关指示灯,17—上右出入口安全开关指示灯,18—上右梳齿异常安全开关指示灯, 19—上右围裙板安全开关指示灯,2 、安全回路AQ(PC输出级COMO\COM1\COM2)至4是控制箱急停,4至5是上急停,5至6是防逆转,6至7是上右围裙板,7至8是上右梳齿,8至9是上右出入口,9至10是驱动连,10至11是上左出入口,11至12是上左梳齿,12至13是上左围裙板,13至14是上梯级下陷,14至15是下控制箱急停,15至16是下急停,16至17是下右出入口,17至18是下右梳齿,18至19是下右围裙板,19至20是下梯级下陷,20至21是下左围裙板,21至22是下左梳齿,22至23是下左出入口,23至24至L43是下链开关,L43到PC电源L。
申龙室外扶梯。
3、故障代码表01 相序检测17 下右出入口检测33 大高度制动行程开关反馈故障02 备用18 下右梳齿检测34 放逆转接触器粘连故障03 上控制柜急停检测(SAU)19 下右围裙检测35 大高度制动接触器触点4、粘连故障04 上部急停检测(SBU)20 下梯级下陷检测36 逆转故障05 机械防逆转开关检测21 下左围裙检测37 梯级缺失故障06 附加制动器安全开关检测22 下左梳齿检测38 主机超速故障07 上右围裙检测23 下左出入口检测39 梯级轮一超速故障08 上右梳齿检测24 下左曳引链检测40 梯级轮2超速故障09 上右出入口检测25 下右曳引链检测41 左扶手带超速故障10 驱动链检测26 备用42 右扶手带超速故障11 上左出入口检测27 主控制器与检测板通讯故障43 主机欠速故障12 上左梳齿检测28 上下行信号粘连故障44 梯级轮1欠速故障13 上左围裙检测29 接触器粘连检测信号粘连故障45 梯级轮2欠速故障14 上梯级下陷、中间急停、保养锁检测30 安全回路故障46 左扶手带欠速故障15 备用31 变频器故障47 右扶手带欠速故障16 下控制箱急停检测32 抱闸行程开关反馈故障48 梯级轮速度不检测故障。
三菱电梯故障维修和调试资料
三菱电梯故障维修和调试资料三菱电梯故障及维修方法一. GPS--2的电梯出现电容不充电.E1板上的充电灯不亮.温度电阻HL1烧毁.请问从哪儿查故障.P1板正常.开关门正常.故障显示E7欠压不启动. 检查发现电容没有炸痕.充电电阻正常.查温度电阻烧毁。
问题原因是:放电模块的问题。
二. SP-VF电梯,刚大修完,更换了旋转编码器及接触器和井道部分电器开关.现出现电梯在运行中突然停止,然后又自动找平层,有时突然停止运行,重新送电一次,电梯运行正常,一天出现几次这样的问题.检查急停及门锁回路未发现异常问题原因是:编码器的问题,把原来的编码器换上后今天一天都没出问题。
三. hope型电梯,出现故障时,停在某一层,平层;轿内照明、风扇都没有;而且外呼无层显、按钮不好用;内选也不好用;查控制柜故障显示为“eb'是向轿厢串行传输错误故障;可断电停个3-5秒再送电,就恢复正常。
问题原因是:换SBC-C的芯片就好了,早期程序问题,升级了以后正常。
四. G(H)VF故障码A1级E11 #10T NO OFF故障E12 #15B NO OFF故障E14 #97输入信号异常E21 #11输入信号异常E22 #12输入信号异常E26 规格表和数出错E27 重复故障检出A2级E31 #100R输入信号异常E32 门区感应器故障E33 变频器异常运行E35 厅轿门动作不一致E36 变频器运行故障E37 电梯逆转故障E40 零速不一致E41 电梯低速超速故障E42 软安全回路继电器NO OFF故障E43 变频器控制回路失电故障E44 #11动作超时故障E45 #12动作超时故障E46 速度低故障B1级E50 高速超速故障E51 起动速度控制异常E52 瞬时停电故障E53 运行速度偏差故障E55 中速超速故障E56 微动平层超速故障E57 微动平层运行距离异常B2级E60 电梯层高表和数出错E61 电梯同步位置出错E62 电梯层楼位置出错E63 电梯端站位置出错E64 电梯端站减速控制异常C2级E70 变频器故障报警检出E73 门区运行故障E76 电梯爬行时间异常E77 自救运行检出E级E80 电梯运行中断门锁检出E81 电梯检修状态异常E82 电梯微动平层超时故障E83 电梯安全回路故障检出E84 微动平层起动故障E85 变频器速度一致信号异常E86 电梯开门超时故障E87 电梯关门超时故障m664=m654强迫减速故障m655厅门轿门开关故障m656=m666运行中50x故障m657=667自救运行故障五. HOPE医用电梯轿厢照明出现问题,照明继电器常吸,造成此原因主要是待梯五分钟自动关闭照明始终带电,为什么会出现这样的问题请指教。
三菱电梯故障代码表
三菱ELENESS电梯故障代码表三菱ELENESS电梯故障查询表三菱ELENESS电梯在顶楼外召电子板上有两个开关 MON和MON0只要旋转这两个开关到不同位置,通过显示出来的字母,在对照相应的中文说明,就可以弄清楚电梯的故障部位和发生故障的时间和次数了。
MON转到0的位置,再将MON开关旋转到0位置,显示结果如下:显示结果--- E0 没有故障---- E1 速度异常过低时检出《 SW-TGB》L---- E2 速度过大是检出《 SW-TGB》H---- E3 逆转是检出《 SW-TGB》R---- E4AST 异常时检出《 SW-AS》T---- E5 逆变器过电流时检出《 SS-LOCF》O---- E6 整流器过电流检出《 SS-COV》H---- E7 整流器电压不足时检出《 SS-LVLT》---- E8LB 线圈故障断电时检出《 SW-CFL》B---- E95 线圈故障断电时检出《 SW-CF》U——EA 迫力接点ON/OFF故障时检出《SW-CFB》---- EB 轿箱直接信号传输异常《 ST-STSCE》---- EC 厅外和指令直接信号传输异常《 ST-STSHE》---- ED 系统异常《 ST-SYER》---- EE 驱动在不能启动《 SD-DNR》S---- EF 控制在不能启动《 SW-NR》S0。
将MON不变,把MON旋转至U 1位置。
显示轿箱与平衡驼的位置,平衡是为0-0之间,显示1等于256MM那么显示2等于512MM将MON不变,把MON旋转至V 2位置。
数据输入《安装时间用,和SW1同时使用》将MON不变,把MON旋转到3位置。
《显示楼层》将MON不变,把MON旋转到4位置。
《显示楼层》将MON不变,把MON旋转至V 5位置。
《称重数据输入,保养时使用》将MON不变,把MON旋转至U 6位置。
手动优先模式将MON不变,把MON旋转到7位置。
《显示楼层》将MON不变,把MON旋转到8位置。
最新苏州申龙电梯主板故障代码SSL-6000上课讲义
苏州申龙电梯主板故障代码SSL-6000故障代码:3故障说明:变频器未准备好故障,即变频器处于故障保护状态;变频器参数设置不当。
故障对策:根据变频器故障显示检查故障来源;检查变频器输出信号(准备完了)的参数设置。
故障代码:4故障说明:变频器运行故障,主板输出方向和使能信号,而变频器运行信号(开闸信号R2)没有给定。
故障对策:检查变频器方向和使能端口设置;检查变频器是否没有接收到方向和使能命令;检查EMERSON CT变频器19.15参数是否打得过低(建议值:600-1200)。
故障代码:5故障说明:编码器信号无反馈故障(编码器故障或电机未转)故障对策:编码器损坏(配同步主机时,编码器损坏电梯是无法正常开慢车);变频器分频输出部件损坏;高速计数输入接口配线错误;电机堵转。
更换编码器;更换变频器分频卡;检查配线;检查抱闸是否未张开。
故障代码:6故障说明:编码器信号错相故障(A、B相接反)故障对策:高速计数的A、B相接反。
调换J16端口A、B相的接线,或调换J17端口的A+与B+,以及A―与B―的接线。
故障代码:8故障说明:R2短接故障,电梯停止时变频器的运行信号(开闸信号R2)依然存在。
故障对策:检查变频器内参数设置;检查变频器运行信号(开闸信号R2)输出点是否粘连。
故障代码:9故障说明:电机热保护。
故障对策:电机热保护装置动作。
故障代码:10故障说明:通讯故障,控制主板与外呼显示板和轿厢主控器不能建立通讯。
故障对策:检查随行电缆的串行通讯电路或接插件有无断线;更换相关控制板。
故障代码:21故障说明:自学习失败故障对策:查看高速计数是否上增下减、门区开关与设定总楼层是否符合、顶层强迫减速是否有效。
故障代码:30故障说明:安全回路断开,安全回路切断或安全回路继电器触点接触不良。
故障对策:检查安全回路的断开部分;更换安全回路继电器。
故障代码:31故障说明:运行中门锁脱开,门刀位置调整不当;门机保持力不够;门锁接触器触点接触不良。
上海三菱电梯故障代码大全
上海三菱电梯故障代码大全摘要: 即便三菱电梯是比较知名的牌子,质量个方面也比较有保障,但三菱电梯也会出现一些故障问题。
三菱电梯从GPS,GPS2 到GPS3,系统机构发生了很大的变化,操作方法有较大差异。
但其基本故障代码是一样的。
在实际维修中,故...即便三菱电梯是比较知名的牌子,质量个方面也比较有保障,但三菱电梯也会出现一些故障问题。
三菱电梯从gps,GPS2 到GPS3,系统机构发生了很大的变化,操作方法有较大差异。
但其基本故障代码是一样的。
在实际维修中,故障代码只是一个维修的参考:主板故障代码:E0 无故障E1 欠速故障E2 超速故障E3 反转故障E4AST 故障(失速)E5 过电流E6 过电压E7 欠电压E8LB 接触器故障E9 接触器故障EA BK 抱闸故障EB 轿厢串行传送故障EC 厅层串行传送故障ED 系统错误(基板跨接器设定错误)EEsddnrs 驱动电脑不能再启动EFswnrs2 控制电脑不能再启动门机板故障代码:0 串行传送错误1 变频器过流2 +12v 欠电压3 主回路欠压4 CPU 之WDT 错误4. GS(门锁)错误5. 位置开关错误7 开关门指令错误9 关门操作错误A 开关门超速A. 位置计数器出错B. 位置监测器出错C. 编码器错误D 过负载E. DLD 余量不足F 超速检查F. GS 释放时指示三菱电梯死机的原因:1. 限位、极限、换速开关距离不当或开关本身不好(注意:慢车有时好开有时不好开);2. 上下限位开关接触不好单向死机或偶尔急停;3. 轻载、超满载数据不好(平层后死机或没有到目的层即紧急停靠平层后死机);4. 超满载板性能不好(平层后死机);5. 平层感应器再平层感应器不好(快车平层后死机)(半年做次自学习);6. 编码器性能不好;7. 编码器尾部插头焊接不好,接触不好(偶尔死机或急停返平层死机,有时不返平层);8. P1 板与W1 板之间的接口接触不好死机(再关电送电好开一段时间又死机);9. 印板灰尘太多,天气潮湿感应电死机(用酒精洗干净,吹干即可);10. 程序块本身性能不好;11. 接地系统不好;12. 通讯部分引起(查有否干扰,查通讯线路、通讯板);13. 扁电缆干扰(平层后死机);14. 电源部分(查供电波形);15. 各主线接触不好引起(包括用户下部);16. 紧急电源识别触点接触不好(NORR 接触器没吸合);17. 主保险丝接触不好有急停现象;18. 基极变压器不好(运行中急停后又自动恢复或平层后死机);19. 基极变压器内部有轻微短路,上行死机,过电压;20. 驱动模块性能差(慢慢平层后死机);21. 驱动板或其插头不好;22. 驱动板上的驱动程序块本身不好或程序不好(运行中急停或平层后死机);23. 逆变器温度过高(会出现瞬时平层后死机,眨眼就恢复);24. 主充电电容容量不够死机(有时开不起来);25. 主充电电容充电瞬间保护的均压电阻接触不好(平层后死机或烧充电电容);26. 互感器插头或本身不好(快慢车均不好开);27. 再生模块性能不好死机;28. 再生电阻不好(接触不好或断线);29. 再生电阻配置错误,在某一个方向上运行到上部或下部满载死机;30. 控制屏输出到主机的大线在互感器的眼中穿错(快慢车均死机);31. 5#接触器、LB 接触器回馈信号不好;32. 抱闸火花消除器到接触器的线接触不好(平层后死机);33. 抱闸触点不好;34. 报闸力的设置过大或过小死机;35. 门机部分不好(查开关门限位,门机编码器);36. 安全触板接触不好(GPS-3)(平层后不能启动,但抱闸张开,在中间层也不返平层);37. 操纵箱基板不好或轿内显示板不好;38. 安全回路有电阻(但灯亮,不动车或急停);39. 门锁回路有电阻(但灯亮,不动车或急停);40. 钢丝绳打滑超过16 次(急停或返平层后死机)。
申龙电梯故障代码
申龙电梯故障代码代码故障说明故障原因故障对策1 控制器复位故障控制器 5V 电源电压偏低或硬件故障调高供电电源至5.25V 更换主控制器2 控制器电源故障控制器电源24V 或5V 供应不正常调换控制器供电电源检查电源配线3 变频器未准备好故障变频器处于故障保护状态变频器参数设置不当根据变频器故障显示检查故障来源检查变频器输出信号准备完了的参数设置4 变频器运行故障控制器输出上行或下行命令而变频器无电流输出检查变频器端口设置使能信号检查变频器是否没有接收到运行命令5编码器信号无反馈故障编码器故障或电机未转编码器损坏变频器分频输出损坏高速计数输入接口配线错误电机堵转更换编码器更换变频器测速反馈选件检查配线检查抱闸是否未张开6编码器信号错相故障A B相接反高速计数的A B相接反调换P14端口A B相的接线8 R2 短接故障停止时变频器的运行反馈信号依然存在检查变频器参数设置检查变频器输出点是否粘连10通讯故障无法建立任何通讯控制器与外呼控制器和轿厢主控器不能建立通讯检查串行通讯电路及接插件有无断线检查通讯芯片损坏检查终端电阻设置断电测量CANH CANL之间电阻为70 左右11 内召信号板通讯故障控制器与轿厢主控器WP-CAN-01 不能建立通讯检查随行电缆的串行通讯电路或接插件有无断线更换轿厢主控器12 外召信号板通讯故障控制器与外呼控制器WP-CAN-03 不能建立通讯检查井道的串行通讯电路或接插件有无断线更换外呼控制器13 内召信号板按钮故障轿内某按钮粘连更换该按钮14 外召信号板按钮故障某层外呼按钮粘连更换该按钮18 IC卡控制板通讯故障控制器与IC 卡控制选件WP-CAN-20A 不能建立通讯检查接往IC 卡控制选件的串行通讯电路或接插件有无断线更换WP-CAN-20A20 自学习运行出错井道自学习未做成功A B 相反强迫减速信号错误电梯参数设置不当上行慢车限位提前动作详见章节11.221自学习楼层与设定值不符总楼层参数设置有误某块隔磁板安装偏离了位置磁开关灵敏度有问题检查总楼层参数设置检查隔磁板安装位置更换磁开关检查门区输入点的常开常闭设置25 减速距离设定错误单层减速距离超过层间距的一半减小减速距离D1 2.5m/s 梯速为D2 的数值30 安全回路断开安全回路切断或安全回路继电器触点接触不良检查安全回路的断开部分更换安全回路继电器31 运行中门锁脱开门刀位置调整不当门机保持力不够门锁接触器触点接触不良调整门机构更换门锁接触器32 门锁短接门锁信号和开门到位信号同时动作拆除门锁短接线检查开门到位开关是否有误动作33 快车状态未停在门区运行中门锁动作相序动作或变频器保护或其他的保护动作检修在非门区转为自动结合其他故障记录综合判断34返平层无法寻到门区信号自返平层至慢车限位动作不见门区信号变化门区磁开关损坏门区信号线断线或接线端松动35高速运行门区信号无变化门区信号丢失电机堵转或轿厢遇阻引起电梯在非门区高速运行超时检查门区信号检查曳引机检查运行保护时间是否设置过短电梯存在超长楼层时36额定速度设定与第一运行速度偏差超过5%变频器参数或控制器参数设置不当引起偏差重新检查参数设置详见章节9.4.3.1 及9.4.3.640 离开门区超时5 秒电梯起动后在5秒内未离开门区检查抱闸是否未张开检查变频器参数设置是否造成加速过于缓慢41 进入门区超时10 秒电梯减速后很长时间不能到达门区检查变频器减速时间是否设定太短检查门区开关是否损坏42顶层底层强迫减速同时动作顶层底层的强迫开关同时起作用检查强迫减速开关是否损坏检查强迫减速信号是否断线43分级强迫减速开关动作顺序有误低一级的强迫减速开关动作而高一级的强迫减速开关未动作检查强迫减速开关是否损坏44加速到额定给定速度超时电梯高速运行速度给定与速度反馈偏差大于20% 且超过10秒加速时间设定过长重新检查参数设置详见章节9.4.3.1 及9.4.3.645 溜车电梯在停车状态出现运动抱闸调节太松轿厢严重超载抱闸机械卡死46 失速电梯速度大于额定梯速的115% 立即动作检查变频器是否速度设置过高重新检查参数设置详见章节9.4.3.1 及9.4.3.6 同步主机反馈信号是否受干扰47 慢车下限位开关动作慢车下限位开关动作限位开关安装偏高正常运行至底层也会动作48 慢车上限位开关动作慢车上限位开关动作限位开关安装偏低正常运行至顶层也会动作49 自返平层超时自返平层超过T0 所设定之时间T0 时间设定过短或存在超长楼层自返平层运行不正常50运行接触器闭合动作超时1.2 秒故障检测到运行接触器粘连故障运行接触器粘连运行接触器辅助触点接触不良51运行接触器断开动作超时1.2 秒故障检测到运行接触器在运行后不动作的故障更换运行接触器52抱闸接触器闭合动作超时1.2 秒故障检测到抱闸接触器粘连故障抱闸接触器粘连抱闸接触器辅助触点接触不良53抱闸接触器断开动作超时1.2 秒故障检测到运行接触器在运行后不动作的故障更换抱闸接触器54抱闸行程开关闭合动作超时1.2 秒故障检测到停车时抱闸没有闸紧故障抱闸机械卡死抱闸行程开关接触不良55抱闸行程开关断开动作超时1.2 秒故障检测到抱闸在运行后不能张开的故障抱闸机械卡死抱闸行程开关接触不良抱闸线圈的控制电路存在接触不良的点60开门受阻不到位超时10 秒电梯开门动作超过10 秒到位开关不见动作清理门机地坎门机低速力矩太小需重新设置门机变频器参数61关门受阻不到位超时10 秒电梯关门动作超过10 秒到位开关不见动作清理门机地坎门机低速力矩太小需重新设置门机变频器参数62开关门到位开关同时动作开关门限位开关同时有效开关门限位开关损坏开关门到位信号逻辑设置常开/常闭设置不对63 到站无法开门电梯到站完全不能开门清理门机地坎开门指令输出断线64安全触板光幕动作超时10 秒安全触板光幕持续动作超时有人挡住门机光幕损坏光幕信号线断线或短路65提前开门反馈信号故障预开门控制器在提前开门区域未能反馈安全信号SL01.2检查上中下门区信号是否有问题更换预开门控制器WEB-POD0166门区信号故障1(提前开门使能时上下门区信号有效而无中门区信号)上下门区同时动作时中门区不动作显然中门区信号有问题更换中门区磁开关检查门区信号线调整磁开关和隔磁板的位置67门区信号故障2(提前开门使能时中门区信号有效而上下门区信号都无效)中门区同时动作时上下门区一个都不动作显然上下门区信号有问题更换上下门区磁开关检查门区信号线调整磁开关和隔磁板的位置70 后门开门受阻不到位超时10 秒电梯后门开门动作超过10 秒到位开关不见动作清理后门门机地坎门机低速力矩太小需重新设置门机变频器参数71 后门关门受阻不到位超时10 秒电梯后门关门动作超过10 秒到位开关不见动作清理后门门机地坎门机低速力矩太小需重新设置门机变频器参数72 后门开关门到位开关同时动作后门开关门限位开关同时有效后门开关门限位开关损坏开关门到位信号逻辑设置常开/常闭设置不对。
三菱电梯ALL故障表
三菱电梯ALL故障表LED1=(1逆变器)(2整流器)(4电源)(5继电器)(6继电器)(7安全回路)(8门)(9井道)(A曳引系统)(B速度)(C秤)(DDR)(E系统设定)(F通信) LED2=(0EST)(1SFS)(2NFS)(3NRS)(4ALT)(5ALT2)LED1/LED2/LED3105SS_GDF E1板门回路异常108SS_WMF 逆变器W相E2板综合故障109SS_VMF 逆变器V相E3板综合故障10A SS_UMF 逆变器U相E4板综合故障10E SD_TOCR 过负荷运行10F SD_SLIT ELD过负荷111SS_LFO E1板综合故障112SY_DESTR E1板故障刷新指令11F SD_HRT 手动过负荷128SW_FTHM2 散热器温度过高异常129SW_FTHMCN 散热器温度检测回路断线12D SW_SOLR 过负荷运行12E SW_SOCR 过负荷运行131SD_CTER DC-CT故障132SD_CVEE 电流检测零点漂移故障138SW_FTHM2 散热器温度过高异常139SW_FTHMCN 散热器温度检测回路断线13D SD_OLR 过负荷运行(再生电阻)13E SD_OCR 过负荷运行13F SD_TOCR 过负荷运行14B SW_FTHM1 温度过高警告202SW_CVER 主回路充电异常204SS_COV 主回路过电压211SS_CLV 主回路欠压231SW_CHGLT 主回路充电中233SW_CVCK 主回路充电异常检查235SW_DCLV 主回路低电压32C SW_CTHM2 散热器温度过高异常32D SW_CTHMCN 散热器温度检测回路断线331SS_WSF 整流侧W相E2板综合故障332SS_VSF 整流侧V相E2板综合故障333SS_USF 整流侧W相E2板综合故障336SF_PLLH E1板锁相环故障33C SW_CTHM2 散热器温度过高异常33D SW_CTHMCN 散热器温度检测回路断线34C SW_CTHM1 散热器温度过高警告411SS_PWF E1板三相电源异常413SS_P12VF 12V电源异常41848V 电源异常419主电源开关断开431切断ELD电源失败441ST_RAMBAK RAM备份开始443驱动侧电源故障511SW_CF5B #5 OFF异常512SW_CF5N #5强制OFF异常513SW_CFLBB #LB OFF异常514SW_CFLBN #LB强制OFF异常515SW_CFBK1A #BK1 ON异常516SW_CFBK1B #BK1 OFF异常517SW_CFBK1N #BK1强制OFF异常518SW_CFBK2A #BK2 ON异常519SW_CFBK2B #BK2 OFF异常51A SW_CFBK2N #BK2强制OFF异常51B SW_CF5A #5 ON异常51C SW_CFLBA #LB ON异常531SW_DF5A #5 ON故障532SW_DF5B #5 OFF故障533SW_DF5N #5强制OFF故障534SW_DFLBA #LB ON故障535SW_DFLBB #LB OFF故障536SW_CFBK1B #LB强制OFF故障537SW_CFBK1N #BK1 ON故障538SW_CFBK2A #BK1 OFF故障539SW_CFBK2B #BK1强制OFF故障53A SW_CFBK2N #BK2 ON故障53B SW_CF5A #BK2 OFF故障53C SW_CFLBA #BK2强制OFF故障53D SW_DFRLA #RL ON故障53E SW_DFRLB #RL OFF故障541SW_CF5A #5 ON故障542SW_CFLBA #LB ON故障543SW_CFBK1A #BK1 ON故障544SW_CFBK2A #BK2 ON故障545SW_CFRLA #RL ON故障546SW_CFRLB #RL OFF故障54D#ED ON 故障611SW_60E 60或60A故障612SW_CFBK3A #BK3 ON异常613SW_CFBK3B #BK3 OFF异常614SW_CFBK3N #BK3强制OFF异常631SW_HDRNA HDRN ON故障632SW_HDRNB HDRN OFF故障633SW_SSUA 控制柜SSU ON故障634SW_SSDA 控制柜SSD ON故障635SW_FSSUC1A 轿顶(前)SSU ON故障636SW_FSSDC1A轿顶(前)SSD ON故障637SW_RSSUC1A 轿顶(后)SSD ON故障638SW_RSSDC1A 轿顶(后)SSD ON故障63A SW_DFBK3A #BK3 ON故障63B SW_DFBK3B #BK3 OFF故障63C SW_DFBK3N #BK3强制OFF故障711SD_32GQ 驱动软件异常712SC_S29 管理软件异常713SW_EST EST动作2次714ELD_D89N ELD动作时#89动作两次719SFS 急停测试71D控制屏门锁断开71F SN_29 29安全回路731SW_D89 #89回路断开732SD_DNRS DR侧不能重启动733SW_EST1 E-STOP 1次734SW_EST2 E-STOP 2次735SC_NRSLRQ 管理不能再启动738极限开关或安全钳动作73D#RSW 动作741SW_29UL 冲顶故障742SW_29DL 蹲底故障743SW_EST1 E-STOP 1次746安全钳动作747极限开关动作748极限开关或安全钳动作74B电梯处于安装模式74D SY_SFRST 安全回路复位指令74E SC_MSALT 管理S/W74F SC_GCALT 群管理S/W761前门门机串行传送异常762前门门机IPM故障763前门门机12V过电压764前门门机主回路欠电压765前门门机DSP的WDT异常766前门门机5V电压异常767前门门机初始化壮态768前门门机的开/关操作逻辑异常769前门门机Z相一次故障76A前门门机最大转速检测76B前门门机过热异常76C前门门机过载异常(长时间电流检测)76D前门门机过速度异常76E前门机械防夹手传感器被遮挡771前门门机轿门开关GS异常772前门门机位置检测异常773前门门机Z相连续故障774前门门机位置的计数区域检查775前门门机位置检查异常OLT检测776前门门机编码器异常777前门门机DLD动作时的显示778前门光幕被遮挡779前门智能光幕自检故障77A前门智能光幕粘连故障77B前门智能光幕断开故障77C前门手动开门事件检出802SW_HALLDOOR_NG 俄罗斯向厅门门锁故障803SW_SAFEWINDOW_NG 俄罗斯向安全窗故障811SW_DOPN 运行中开门812SS_DKC 开门运行(SLC)823SW_41DGB 41DG OFF故障824SW_FCLT12B 前门CLT OFF故障825SW_RCLT12B 后门CLT OFF故障826SW_FSDE12B 前门SDE OFF故障827SW_RSDE12B 后门SDE OFF故障82E SW_E41S 门锁短接故障831SW_41DGA 41DG ON异常832SW_FOLT12B 前门OLT OFF故障833SW_ROLT12B 后门OLT OFF故障834SW_HALLDOOR_NG 俄罗斯向厅门故障835SW_SAFEWINDOW_NG 俄罗斯向安全窗故障836门锁旁路信号异常838CC检出前门CLT ON故障839CC检出后门CLT ON故障83A门机检出前门CLT ON故障83B门机检出后门CLT ON故障83E SW_E41S 门锁短接故障83F SW_CFD41A #D41 ON故障841SW_DSONP 层站DS开门检出(EN81) 842SW_DFCLT12A 前门CLT ON故障843SW_DFCLT12B 前门CLT OFF故障844SW_DRCLT12A 后门CLT ON故障845SW_DRCLT12B 后门CLT OFF故障846SW_DFFG12A 前门FG ON故障847SW_DFFG12B 前门FG OFF故障848SW_DRFG12A 后门FG ON故障849SW_DRFG12B 后门FG OFF故障84A SW_DFOLT12A 前门OLT ON故障84B SW_DFOLT12B 前门OLT OFF故障84C SW_DROLT12A 后门OLT ON故障84D SW_DROLT12B 后门OLT OFF故障84E SW_FRE41S12 门锁短接故障84F SW_CFD41B #D41 OFF故障851SW_D41DGA 41DG ON故障852SW_D41DGB 41DG OFF故障856门锁旁路信号异常85C前门GS短接故障85D后门GS短接故障85E DS短接故障85F41DG短接故障861后门门机串行传送异常862后门门机IPM故障863后门门机12V过电压864后门门机主回路欠电压865后门门机DSP的WDT异常866后门门机5V电压异常867后门门机初始化壮态868后门门机的开/关操作逻辑异常869后门门机Z相一次故障86A前门门机最大转速检测86B后门门机过热异常86C后门门机过载异常(长时间电流检测)86D后门门机过速度异常86E后门机械防夹手传感器被遮挡871后门门机轿门开关GS异常872后门门机位置检测异常873后门门机Z相连续故障874后门门机位置的计数区域检查875后门门机位置检查异常OLT检测876后门门机编码器异常877后门门机DLD动作时的显示878后门光幕被遮挡879后门智能光幕自检故障87A后门智能光幕粘连故障87B后门智能光幕断开故障87C后门手动开门事件检出90B SW_UMD_DETECT UCMP动作911上轿顶运行1次914SW_FRLUB 前门RLU OFF故障915SW_FRLDB 前门RLD OFF故障916SW_RRLUB 后门RLU OFF故障917SW_RRLDB 后门RLD OFF故障91A SS_ETSWDT ETS WDT故障91D SW_UDLB UL/DL都动作91E SW_DLC 下行DL开关动作91F SW_ULC 上行UL开关动作931SW_FDZUA 前门DZU ON故障932SW_FDZDA 前门DZD ON故障933SW_FRLUA 前门RLU ON故障934SW_FRLDA 前门RLD ON故障935SW_RDZUA 后门DZU ON故障936SW_RDZDA 后门DZD ON故障937SW_RRLUA 后门RLU ON故障938SW_RRLDA 后门RLD ON故障939SW_UDHSA UHS/DHS ON故障93A SW_TSWER 终端开关故障93B SW_DZCCAB DZ检测电路ON/OFF故障93C SW_FRDZRL 前门/后门平层、再平层信号时序异常93D SW_FRDZX 前门平层信号、后门平层信号逻辑异常93E SW_UDLUDSRX UL/DL/USR/DSR信号逻辑异常93F SW_UDLUDSRB UL和DL,或USR和DSR开关同时动作941SW_TS3DE USR/DSR ON/OFF故障942SW_TS3E 终端开关逻辑异常948上轿顶模式949SW_FDZRLX 前门平层、再平层信号时序异常94A SW_RDZRLX 后门平层、再平层信号时序异常94B SW_DZCCAB DZ 检测电路ON/OFF故障94C SW_FMCTE 层数计数异常94D SW_FRDZX1 前门平层信号逻辑异常94E SW_FRDZX2 后门平层信号逻辑异常95B SW_UMDA #UMD ON故障95E UDSD/UDSR信号不一致A01SD_BKEH B1板断线故障A02SS_SWCH B1板电源故障A18SW_CFBK1N #BK1强迫OFFA19SW_CFBK3N #BK3强迫OFFA1A SW_CFBK2N #BK2强迫OFFA1B SW_UVWOFF UVW断线检测A1E SW_ENCCNF_HAND 手动运行编码器计数异常A1F SW_ENCCNF_AUTO 自动运行编码器计数异常A21SW_MTHM 电机温度异常A22SW_BKERNF 制动器异常A31SW_MTHM 电机温度异常A31SW_BKERNR 制动器异常A39SS_SWCH W2板未接A3A SS_BKE W2板异常A3B SW_JZER JZER故障A3C SW_UVWOFF UVW断相检测A3D SD_THNG 磁极未学习A3E SD_AZER PM Z相异常A3F SD_AEER F相异常B01SW_TGBL 过低速B02SW_TGBH 过高速B03SW_TGBR 逆行B04SW_AST 曳引机堵转B05SW_TGBX 编码器偏差B07SW_TGRL 再平层异常B08SW_ASTW 钢丝绳打滑B0D SS_DEST SLC急停B0E SS_TGBH SLC过高速B0F SS_AST SLC失速B11SW_TGBL 过低速B12SD_PVJP 速度与图形偏差故障B13SW_DECT 减速时限B14SW_LOVR 行程过头B18SW_LOS 手动过高速B21SW_RLT 再平层时限B23SW_DECTN 减速时限(缓停止) B31SD_OVJP 速度与图形比较16次B32ST_LSA 运行检测B33SW_SELD 选层器故障B34SW_TSAK TSD运行B35SW_AST 曳引机堵转B37SW_TGRL 再平层异常B38SW_FMSER FMS失败B42ST_SLZQ 选层器偏差警告B43ST_SELZ 选层器偏差故障B44ST_THNG 磁极未学习B46ST_TLPRN TLP行走检出C21SW_WGE2 运行中秤异常C23SW_WGCN 秤装置断线C31SW_WGE2 运行中秤异常C32SW_WGE1 停止中秤异常C33SW_WGCN 秤装置断线C34SW_WGWE 秤设定异常D01SS_DEST SLC急停D02SS_TGBH SLC过高速D03SS_AST SLC失速D11SS_DKC SLC开门运行D12SS_TSDNG SLC TSD异常D13SS_MCP_D5 DR D5指令D14SS_MCP_D89 DR D89指令D1B SS_CCWC5 CC_WDT5次D1C SS_CCWC4 CC_WDT4次D31SD_MCPWDE DR WDT故障D3D SS_CCWC3 CC_WDT3次D41SS_MCPT10S DR WDT屏蔽定时器动作D43SS_MCP_D5 DR D5指令D44SS_MCP_D89 DR D89指令D4A SS_CCT10S CC_WDT屏蔽定时器动作D4E SS_CCWC2 CC_WDT2次D4F SS_CCWC1 CC_WDT1次E31UCMP装置功能失效E32SD_RAMER 驱动RAM故障E33SD_DTER 驱动系统设定故障E35SW_ASYSER ACC代码设定故障E36SW_TSYER 曳引机设定故障E37SW_SSYER 速度设定故障E39SW_RAMER 控制RAM故障E3A CC软件与电气硬件不兼容E3D UCMP装置检出故障E41SW_EP1 P1B验证失败E42SW_EGC GCB验证失败E43SW_EHS HS验证失败(至少有一个) E44SW_ECS CS验证失败(至少有一个)E45SW_EBC BC验证失败(至少有一个) E46SW_EIC IC验证失败(至少有一个) F31SW_STER_P1ACL P1CL故障F34SW_STER_ASC1 SC故障F35SW_STER_FCS1 前门CS故障F36SW_STER_FDC1 前门DC故障F37SW_STER_RCS1 后门CS故障F38SW_STER_RDC1 后门DS故障F39SW_STER_WGD 秤故障F3A SW_STER_FBC1 前门BC1故障F3B SW_STER_RBC1 后门BC1故障F3D UCMP装置通讯故障F41SW_P1ACL_HNG P1ACL故障F44SW_ASC1_HNG SC故障F45SW_FCS1_HNG 前门CS故障F46SW_FDC1_HNG 前门DC故障F47SW_RCS1_HNG 后门CS故障F48SW_RDC1_HNG 后门DS故障F51SW_HSALL_DOWN_HNG HS故障F52SW_FIC1_HNG 前门IC故障F53SW_RIC1_HNG 后门IC故障F54SW_FBC1_HNG 前门BC1故障F55SW_FBC2_HNG 前门BC2故障F56SW_FBC3_HNG 前门BC3故障F57SW_FBC4_HNG 前门BC4故障F58SW_RBC1_HNG 后门BC1故障F59SW_RBC2_HNG 后门BC2故障F5A SW_RBC3_HNG 后门BC3故障F5B SW_RBC4_HNG 后门BC4故障F5C SW_HIP_NG HIP板未接F5D UCMP装置通讯故障。
苏州申龙扶梯故障显示对照图
苏州申龙扶梯故障显示对照图故障显示对照图01 —— E1 相序、热继电器02 —— E2 备用03 —— E3 上控制柜急停按钮(SUA)04 —— E4 上部急停按钮05 —— E5 机械防逆转安全开关06 —— E6 附加制动器安全开关07 —— E7 上右围裙板安全开关08 —— E8 上右梳齿板异常安全开关09 —— E9 上右出入口安全开关10 —— E10 驱动链断链安全开关11 —— E11 上左出入口安全开关12 —— E12 上左梳齿板异常安全开关13 —— E13 上左围裙板安全开关14 —— E14 上梯级下陷安全开关、中间急停、保养锁安全开关15 —— E15 备用16 —— E16 下控制箱急停按钮、下部急停按钮17 —— E17 下右出入口安全开关18 —— E18 下右梳齿异常开关19 —— E19 下右围裙板安全开关20 —— E20 下梯级下陷安全开关21 —— E21 下左围裙板安全开关22 —— E22 下左梳齿板安全开关23 —— E23 下左出入口安全开关24 —— E24 下左曳引链安全开关25 —— E25 下右曳引链安全开关26 —— E26 备用27 ——主控制器与故障检测板通讯故障28 ——上、下行信号粘连故障29 ——接触器粘连检测粘连故障30 ——安全回路故障31 ——变频器故障32 ——抱闸行程开关反馈故障33 ——大高度制动行程开关反馈故障34 ——机械防逆转接触器触点粘连故障35 ——大高度制动接触器(电容后端)触点粘连故障36 ——逆转故障37 ——梯级缺失故障38 ——主机超速故障39 ——梯级轮一超速故障40 ——梯级轮二超速故障41 ——左扶手带超速故障42 ——右扶手带超速故障43 ——主机欠速故障44 ——梯级轮一欠速故障45 ——梯级轮二欠速故障46 ——右扶手带欠速故障47 ——右扶手带欠速故障48 ——梯级轮速度不检测故障。
电梯故障代码
电梯故障及功能对照表MON1与MON0故障及功能对照表MON1-1或5MON0-0 控制S/W NRS原因表示E00 没有异常E01 温度异常E02 紧急停止运行记录1次(SW-THMFT)E03 CC-WDT3次检出(SS-CCWC3)-4E04 SLC-WDT4次检出(SW-SOCR)-3E05 电流检出(SW-SOCR)E06 回生电阻负荷过大(SW-SOLR)-2E07 41DG锁闸锁线路异常(SW-E41)E08 终端限位制异常(SW-TSCK)E09 PAD异常检出(SW-PAD)平层感应器E0A 秤数值异常检出(SW-WGER)E0B 停止中PAD异常检出(SW-PAE)E0C 充电异常,有充电回路才有效(SW-CHRGT)E0D 再平层时异常检出(SW-PRLE)MON0-01 控制S/W NRS原因表示E10 没有异常E11 复位后重试不能(SW-RSRTC)E12 士力铊16次异常检出(ST-SELD)E13 直接传输CPU传送异常(ST-STER)E14 电容器异常检出(ST-CAPC)E15 手动按钮异常(ST-HDOK)E16 模式与测速数据偏差异常(SD-OVJP)E17 #LB线圈运续4次异常断电检出(ST-DFLB)E18 #5线圈连续4次异常断电检出(ST-DF5)E19 迫力接点回路连续4次异常检出(ST-DFBK)E1A 整流器电压不足8次检出(ST-DFLV)E1B #RL异常时检出(SW-CFRL)E1C TSD动作时异常检出(SW-TSLDE)E1D #ESP动作时异常检出(SW-ESPE)MON0-02 控制S/W NRS原因表示E20 没有异常E21 #89回路异常检出(SW-E89)E22 紧急停止运行记录2次(SW-EST2)E23 系统异常(ST-SYER)E24 回复后再尝试检出(ST-RSRQH)E25 集极驱动板异常(SS-GDFH)E26 DC-CT 异常(SD-CTER)E27 油压迫力压力过低时检出(SW-OPFER)E28 油压迫力温度,油量异常检出(SW-OTLER)E29 温度异常(SW-THMME)E2A 与最终速度偏差异常(ST-UMCH)E2B 异常紧急停车后再起动不能(SW-ETSE)E2C 迫力异常动作2次(SW-RFBK2)E2D 整流器充电异常(SW-VCHGT)E2E MELD 制板充电异常(SD-MCHG)-2MON0-03 控制S/W E-STOP原因表示E30 没有异常E31 MELD 负载过大(SD-SLIT)-2E32 异常低速(SW-TGBL)E33 速度异常过高(SW-TGBT)E34 AST异常动作(SW-AST)E35 逆转运行(SW-TGBR)E36 AST异常动作(SW-ASTW)低速机使用E37 AST异常动作(SW-ASTWV)低速机使用E38 整流器电压过大时检出(SS-COVH)E39 整流器电压过低时检出(SS-CLVT)E3A CC-WDT4次检出(SS-CCWC4)-4E3B SLC-WDT5次检出(SS-SLCWC5)-3E3C 逆变器电流过大时检出(SS-IOCFO)E3D SLC——CPU内之紧急停止动作检出(SS-DEST)-3E3E 整流器充电异常(SW-VCER)MON0-04 控制S/W E-STOP原因表示E40 没有异常E41 紧急停止运行记录2次(SW-EST2)E42 整流器电压过低时检出(SS-LVLTI)E43 紧急停止回复(SW-ESTR)E44 #LB线圈故障断电检出(SW-CFLB)E45 #5线圈故障断电时检出(SW-CF5)E46 迫力接点回路连续4次异常检出(ST-CFBK)E47 #89线圈故障断电时检出(SW-CF89)E48 #89故障断电时检出(SY-89ST)MON0-05 控制S/W E-STOP原因表示E50 没有异常E51 #29安全回路检出(SN29)E52 #29安全回路动作时检出(SS-29LT)锁存记忆E53 欠相或电源过低时检出(SS-PWFH)E54 整流器电压不足时检出(SS-LVLT)E55 12V电源异常(SS-12VFL)E56 模式与测速比较有偏差(SD-PTC)E57 手动模式时电流负荷过大(SD-HRT)E58 驱动发出之紧急停止指令(SD-32GQ)E59 紧急停止指令(SC-S29)E5A 迫力基板异常(SS-BKE)E5B 模式与测速比较有偏差(SW-VPTC)E5C ETS异常而引致不能再起动(SW-ETSES)MON0-06 控制H/W安全回路异常原因表示E60 没有异常E61 整流器电压不足时检出(SS-LVLT)E62 集极驱动基极异常E63 逆变器保护回路动作E64 #29安全回路动作时检出(SS-29LT)锁存记忆E65 12V电源异常(SS-12VFL)E66 逆变器测试异常检出E67 锁相环检出E68 整流器电流过大E69 逆变器电流过大过检出E6A 整流器电压过大时检出(SS-COVH)E6B 欠相或电源过低时检出(SS-PWFH)MON0-07 控制H/W安全回路异常原因表示E70 没有异常E71 CC-WDT5次异常检出(SS-CCWC5)-3E72 CC-WDT4次异常检出(SS-CCWC4)-3E73 CC-WDT3次异常检出(SS-CCWC3)-3E74 SLC-WD5次异常检出(SS-SLCWC5)-4E75 SLC-WD4次异常检出(SS-SLCWC4)-4E76 SLC-WD3次异常检出(SS-SLCWC3)-4MON0-09 驱动S/W 异常原因表示E90 没有异常E92 电流负载过大(SD-OCR)E93 不能再次起动(SD-DNRS)E94 MELD负荷过大检出(SD-SLII)-2E95 TSD不正常动作检出(SD-TSDP)E96 行走中秤异常检出(SD-WGHTF2)E97 DC-CT 异常(SD-CTER)E98 TST异常动作检出(SD-TSA)E99 摩打解码器之"Z"相异常检出(SD-AZER)E9A 摩打解码器之"F"相异常检出(SD-AEER)E9B PM摩打时限电流过大(SD-TOCR)MON0-A 驱动S/W 异常原因表示EA0 没有异常EA1 模式与测速数据偏差异常(SD-PVJP)EA2 模式与测速数据偏差异常(SD-OVJP)EA3 驱动发出之紧急停止指令(SD-32GQ)EA4 回生电阻负荷过大(SD-SOLR)EA5 本机模式与测速比较有偏差(SD-PTC)EA6 手动模式时电流负荷过大(SD-HRT)EA7 逆变器电流过大时检出(SD-IOCF)EA8 TSD-PAD故障检出(SD-PADE)EA9 MCP检出整流器电流过大(SD-COCF)-5EAA MCP初期设定异常(SD-INITF)-5EAB RAM异常检出(SD-RAMER)EAC 卷上机设定数据异常(SD-DTER)EAD MCP重新启动异常检出(SD-RBOTNG)-5EAE MCP-WDT4次异常检出(SD-MCPWDE)-5MON0-B 管理S/W异常原因表示EB0 没有异常EB1 停机10分钟后不能再起动(SW-32DT10)EB2 停机16分钟后不能再起动(SW-32DT16)EB3 再不能起动超过10分钟(SW-DSTE10)EB4 再不能起动超过10分钟(SW-57EBT)EB5 门不能开启超过2分钟(SW-CONE)EB6 FUSE断路超过2分钟(SW-EFSOF)EB7 #60异常检出(SW-60CHK)EB8 门不能开启(SW-NLH)EB9 主控制板异常检出(SQ-MBCIJH)EBB 困人警报(SZ-EMAH)EBC 警报不能使用(SZ-EMEH)EBD 群控管理异常(SZ-GCIJO)MON0-C H/W安全回路异常原因表示EC0 没有异常EC1 SLC传输异常(SS-TRER)-3EC2 SLC之紧急停止动作(SS-DEST)-3EC3 SLC内之速度过高(SS-TGBH)-3EC4 SLC之AST动作(SS-AST)-3EC5 SLC内之KC动作(SS-DKC)-3EC6 SLC之RAM异常检出(SS-RAMER)-3MON0-D 驱动S/W 异常原因表示ED0 没有异常ED1 机厢正门拎手BC-CPU1异常检出(SF-FBC1IJH)-4ED2 机厢正门拎手BC-CPU2异常检出(SF-FBC2IJH)-4ED3 机厢正门拎手BC-CPU3异常检出(SF-FBC3IJH)-4ED4 机厢正门拎手BC-CPU4异常检出(SF-FBC4IJH)-4ED5 正门CAR-STATION之CPU 异常检出(SF-FCSIJH)ED6 正门控制之CPU检出(SF-FDCIJH)ED7 正门机厢显示灯之CPU异常检出(SF-FICIJH)ED8 正门机厢之OPTION-CPU 异常检出(SF-FCZIJH)ED9 SC-CPU严重故障(SC-SCER8)-5EDA SC-CPU严重故障(SC-SHER8)-6EDB SC-CPU轻微故障(SC-SCER)-5EDC SC-CPU轻微故障(SC-SHER)-6EDD HIS-CPU故障(SC-HSAIJ)-6MON0-D 驱动S/W 异常原因表示EE0 没有异常EE1 机厢后门拎手BC-CPU5异常检出(SF-RBC5IJH)EE2 机厢后门拎手BC-CPU6异常检出(SF-RBC6IJH)EE3 机厢后门拎手BC-CPU7异常检出(SF-RBC7IJH)EE4 机厢后门拎手BC-CPU8异常检出(SF-RBC8IJH)EE5 后门CAR-STATION之CPU 异常检出(SF-RCSIJH)EE6 后门控制之CPU异常检出(SF-RDCIJH)EE7 后门机厢显示灯之CPU异常检出(SF-RICIJH)EE8 后门机厢之OPTION-CPU 异常检出(SF-RCZIJH)。
申龙电梯故障码
SSL-6000 故障代码故障代码:3故障说明:变频器未准备好故障,即变频器处于故障保护状态;变频器参数设置不当。
故障对策:根据变频器故障显示检查故障来源;检查变频器输出信号(准备完了)的参数设置。
故障代码:4故障说明:变频器运行故障,主板输出方向和使能信号,而变频器运行信号(开闸信号R2)没有给定。
故障对策:检查变频器方向和使能端口设置;检查变频器是否没有接收到方向和使能命令;检查EMERSON CT变频器19.15参数是否打得过低(建议值:600-1200)。
故障代码:5故障说明:编码器信号无反馈故障(编码器故障或电机未转)故障对策:编码器损坏(配同步主机时,编码器损坏电梯是无法正常开慢车);变频器分频输出部件损坏;高速计数输入接口配线错误;电机堵转。
更换编码器;更换变频器分频卡;检查配线;检查抱闸是否未张开。
故障代码:6故障说明:编码器信号错相故障(A、B相接反)故障对策:高速计数的A、B相接反。
调换J16端口A、B相的接线,或调换J17端口的A+与B+,以及A―与B―的接线。
故障说明:R2短接故障,电梯停止时变频器的运行信号(开闸信号R2)依然存在。
故障对策:检查变频器内参数设置;检查变频器运行信号(开闸信号R2)输出点是否粘连。
故障代码:9故障说明:电机热保护。
故障对策:电机热保护装置动作。
故障代码:10故障说明:通讯故障,控制主板与外呼显示板和轿厢主控器不能建立通讯。
故障对策:检查随行电缆的串行通讯电路或接插件有无断线;更换相关控制板。
故障代码:21故障说明:自学习失败故障对策:查看高速计数是否上增下减、门区开关与设定总楼层是否符合、顶层强迫减速是否有效。
故障代码:30故障说明:安全回路断开,安全回路切断或安全回路继电器触点接触不良。
故障对策:检查安全回路的断开部分;更换安全回路继电器。
故障说明:运行中门锁脱开,门刀位置调整不当;门机保持力不够;门锁接触器触点接触不良。
故障对策:调整门机构;更换门锁接触器。
三菱电梯凌云主板故障代码
三菱电梯凌云主板故障代码主板故障代码:E0 无故障E1 欠速故障E2 超速故障E3 反转故障E4AST故障(失速)E5 过电流E6 过电压E7 欠电压E8LB接触器故障E9接触器故障EA BK抱闸故障EB轿厢串行传送故障EC厅层串行传送故障ED系统错误(基板跨接器设定错误) EEsddnrs 驱动电脑不能再启动EFswnrs2 控制电脑不能再启动门机板故障代码:0 串行传送错误1 变频器过流2 +12v欠电压3 主回路欠压4 CPU之WDT错误4. GS(门锁)错误5. 位置开关错误7 开关门指令错误9 关门操作错误A 开关门超速A. 位置计数器出错B. 位置监测器出错C. 编码器错误D 过负载E. DLD余量不足F 超速检查F. GS释放时指示三菱电梯死机的原因:1. 限位、极限、换速开关距离不当或开关本身不好(注意:慢车有时好开有时不好开);2. 上下限位开关接触不好单向死机或偶尔急停;3. 轻载、超满载数据不好(平层后死机或没有到目的层即紧急停靠平层后死机);4. 超满载板性能不好(平层后死机);5. 平层感应器再平层感应器不好(快车平层后死机)(半年做次自学习);6. 编码器性能不好;7. 编码器尾部插头焊接不好,接触不好(偶尔死机或急停返平层死机,有时不返平层);8. P1 板与W1 板之间的接口接触不好死机(再关电送电好开一段时间又死机);9. 印板灰尘太多,天气潮湿感应电死机(用酒精洗干净,吹干即可);10. 程序块本身性能不好;11. 接地系统不好;12. 通讯部分引起(查有否干扰,查通讯线路、通讯板);13. 扁电缆干扰(平层后死机);14. 电源部分(查供电波形);15. 各主线接触不好引起(包括用户下部);16. 紧急电源识别触点接触不好(NORR 接触器没吸合);17. 主保险丝接触不好有急停现象;18. 基极变压器不好(运行中急停后又自动恢复或平层后死机);19. 基极变压器内部有轻微短路,上行死机,过电压;20. 驱动模块性能差(慢慢平层后死机);21. 驱动板或其插头不好;22. 驱动板上的驱动程序块本身不好或程序不好(运行中急停或平层后死机);23. 逆变器温度过高(会出现瞬时平层后死机,眨眼就恢复);24. 主充电电容容量不够死机(有时开不起来);25. 主充电电容充电瞬间保护的均压电阻接触不好(平层后死机或烧充电电容);26. 互感器插头或本身不好(快慢车均不好开);27. 再生模块性能不好死机;28. 再生电阻不好(接触不好或断线);29. 再生电阻配置错误,在某一个方向上运行到上部或下部满载死机;30. 控制屏输出到主机的大线在互感器的眼中穿错(快慢车均死机);31. 5#接触器、LB 接触器回馈信号不好;32. 抱闸火花消除器到接触器的线接触不好(平层后死机);33. 抱闸触点不好;34.抱闸力的设置过大或过小死机;35. 门机部分不好(查开关门限位,门机编码器);36. 安全触板接触不好(GPS-3)(平层后不能启动,但抱闸张开,在中间层也不返平层);37. 操纵箱基板不好或轿内显示板不好;38. 安全回路有电阻(但灯亮,不动车或急停);39. 门锁回路有电阻(但灯亮,不动车或急停);40. 钢丝绳打滑超过16 次(急停或返平层后死机)。
苏州申龙3000常见故障代码及对策
第十二章常见故障代码及对策代码故障说明故障原因故障对策3 变频器未准备好故障变频器处于故障保护状态;变频器参数设置不当根据变频器故障显示检查故障来源;检查变频器输出信号(准备完了)的参数设置。
4 变频器运行故障控制器输出上行或下行命令,而变频器无电流输出检查变频器端口设置(使能信号);检查变频器是否没有接收到运行命令。
5 编码器信号无反馈故障(编码器故障或电机未转)编码器损坏;变频器分频输出损坏;高速计数输入接口配线错误;电机堵转更换编码器;更换变频器测速反馈选件;检查配线;检查抱闸是否未张开6 编码器信号错相故障(A、B相接反)高速计数的A、B相接反调换P8端口A、B相的接线8 R2短接故障停止时变频器的运行反馈信号依然存在检查变频器参数设置;检查变频器输出点是否粘连9 电机热保护电机热保护装置动作10 通讯故障控制器与外呼,轿厢主控器不能建立通讯检查随行电缆的串行通讯电路或接插件有无断线;更换相关控器30 安全回路断开安全回路切断或安全回路继电器触点接触不良检查安全回路的断开部分;更换安全回路继电器31 运行中门锁脱开门刀位置调整不当;门机保持力不够;门锁接触器触点接触不良调整门机构;更换门锁接触器32 门锁短接门锁信号和开门到位信号同时动作拆除门锁短接线;检查开门到位开关是否有误动作33 快车状态未停在门区运行中门锁动作、相序动作或变频器保护或其他的保护动作;检修在非门区转为自动结合其他故障记录综合判断35 运行超时故障门区信号丢失、电机堵转或轿厢遇阻引起电梯在非门区高速运行超时检查门区信号;检查曳引机;检查运行保护时间是否设置过短(电梯存在超长楼层时)40 离开门区超时5秒电梯起动后在5秒内未离开门区检查抱闸是否未张开;检查变频器参数设置是否造成加速过于缓慢41 低速运行超时60秒电梯减速后60秒不能到达门区检查变频器减速时间是否设定太短;检查门区开关是否损坏42 顶层、底层强迫减速同时动作顶层、底层的强迫开关同时起作用检查强迫减速开关是否损坏;检查强迫减速信号是否断线46 失速电梯速度大于额定梯速的115%,立即动作检查变频器是否速度设置过高;重新检查参数设置47 慢车下限位开关动作慢车下限位开关动作限位开关安装偏高,正常运行至底层也会动作48 慢车上限位开关动作慢车上限位开关动作限位开关安装偏低,正常运行至顶层也会动作50 运行接触器闭合动作超时1.2秒故障检测到运行接触器粘连故障运行接触器粘连;运行接触器辅助触点接触不良51 运行接触器断开动作超时1.2秒故障检测到运行接触器在运行后不动作的故障更换运行接触器52 抱闸接触器闭合动作超时1.2秒故障检测到抱闸接触器粘连故障抱闸接触器粘连;抱闸接触器辅助触点接触不良53 抱闸接触器断开动作超时1.2秒故障检测到运行接触器在运行后不动作的故障更换抱闸接触器54 抱闸行程开关闭合动作超时1.2秒故障检测到停车时抱闸没有闸紧故障抱闸机械卡死;抱闸行程开关接触不良55 抱闸行程开关断开动作超时1.2秒故障检测到抱闸在运行后不能张开的故障抱闸机械卡死;抱闸行程开关接触不良;抱闸线圈的控制电路存在接触不良的点60 开门受阻不到位超时10秒电梯开门动作超过10秒,到位开关不见动作清理门机地坎;门机低速力矩太小,需重新设置门机变频器参数61 关门受阻不到位超时10秒电梯关门动作超过10秒,到位开关不见动作清理门机地坎;门机低速力矩太小,需重新设置门机变频器参数62 开关门到位开关同时动作开关门限位开关同时有效开关门限位开关损坏;开关门到位信号逻辑设置(常开/常闭)设置不对64 安全触板、光幕动作超时10秒安全触板、光幕持续动作超时有人挡住门机;光幕损坏;光幕信号线断线或短路65 UPS运行U PS信号输入66 关门到位门锁不通关门已到位而门锁不通调整门机构开关点位置;调整变频门机参数;调换门锁装置70 慢车限位开关同时动作S5W点和S6W点同时有效;71 高速强迫减速开关同时动作S3W点和S4W点同时有效;72 下中速强迫减速开关粘连电梯离开底层9秒钟内S1W一直有效73 上中速强迫减速开关粘连电梯离开顶层9秒钟内S2W一直有效74 下高速速强迫减速开关粘连电梯离开底层9秒钟内S3W一直有效75 上高速强迫减速开关粘连电梯离开顶层9秒钟内S4W一直有效77 高速电梯中,强迫开关位置错误在下行碰到S1W时电梯速度比此一级强迫减速对应的速度如果大于设定速度比例(%),电梯报77号故障,反之上行也报77号故障。
申龙电梯故障表
申龙电梯故障表(共7页)--本页仅作为文档封面,使用时请直接删除即可----内页可以根据需求调整合适字体及大小--故障代码:3故障说明:变频器未准备好故障,即变频器处于故障保护状态;变频器参数设置不当。
故障对策:根据变频器故障显示检查故障来源;检查变频器输出信号(准备完了)的参数设置。
故障代码:4故障说明:变频器运行故障,主板输出方向和使能信号,而变频器运行信号(开闸信号R2)没有给定。
故障对策:检查变频器方向和使能端口设置;检查变频器是否没有接收到方向和使能命令;检查EMERSON CT变频器参数是否打得过低(建议值:600-1200)。
故障代码:5故障说明:编码器信号无反馈故障(编码器故障或电机未转)故障对策:编码器损坏(配同步主机时,编码器损坏电梯是无法正常开慢车);变频器分频输出部件损坏;高速计数输入接口配线错误;电机堵转。
更换编码器;更换变频器分频卡;检查配线;检查抱闸是否未张开。
故障代码:6故障说明:编码器信号错相故障(A、B相接反)故障对策:高速计数的A、B相接反。
调换J16端口A、B相的接线,或调换J17端口的A+与B+,以及A―与B―的接线。
故障代码:8故障说明:R2短接故障,电梯停止时变频器的运行信号(开闸信号R2)依然存在。
故障对策:检查变频器内参数设置;检查变频器运行信号(开闸信号R2)输出点是否粘连。
故障代码:9故障说明:电机热保护。
故障对策:电机热保护装置动作。
故障代码:10故障说明:通讯故障,控制主板与外呼显示板和轿厢主控器不能建立通讯。
故障对策:检查随行电缆的串行通讯电路或接插件有无断线;更换相关控制板。
故障代码:21故障说明:自学习失败故障对策:查看高速计数是否上增下减、门区开关与设定总楼层是否符合、顶层强迫减速是否有效。
故障代码:30故障说明:安全回路断开,安全回路切断或安全回路继电器触点接触不良。
故障对策:检查安全回路的断开部分;更换安全回路继电器。
故障代码:31故障说明:运行中门锁脱开,门刀位置调整不当;门机保持力不够;门锁接触器触点接触不良。
苏州申龙电梯主板故障代码SSL
苏州申龙电梯主板故障代码S S LThe document was finally revised on 2021苏州申龙电梯主板故障代码SSL-6000故障代码:3故障说明:变频器未准备好故障,即变频器处于故障保护状态;变频器参数设置不当。
故障对策:根据变频器故障显示检查故障来源;检查变频器输出信号(准备完了)的参数设置。
故障代码:4故障说明:变频器运行故障,主板输出方向和使能信号,而变频器运行信号(开闸信号R2)没有给定。
故障对策:检查变频器方向和使能端口设置;检查变频器是否没有接收到方向和使能命令;检查EMERSON CT变频器参数是否打得过低(建议值:600-1200)。
故障代码:5故障说明:编码器信号无反馈故障(编码器故障或电机未转)故障对策:编码器损坏(配同步主机时,编码器损坏电梯是无法正常开慢车);变频器分频输出部件损坏;高速计数输入接口配线错误;电机堵转。
更换编码器;更换变频器分频卡;检查配线;检查抱闸是否未张开。
故障代码:6故障说明:编码器信号错相故障(A、B相接反)故障对策:高速计数的A、B相接反。
调换J16端口A、B相的接线,或调换J17端口的A+与B+,以及A―与B―的接线。
故障代码:8故障说明:R2短接故障,电梯停止时变频器的运行信号(开闸信号R2)依然存在。
故障对策:检查变频器内参数设置;检查变频器运行信号(开闸信号R2)输出点是否粘连。
故障代码:9故障说明:电机热保护。
故障对策:电机热保护装置动作。
故障代码:10故障说明:通讯故障,控制主板与外呼显示板和轿厢主控器不能建立通讯。
故障对策:检查随行电缆的串行通讯电路或接插件有无断线;更换相关控制板。
故障代码:21故障说明:自学习失败故障对策:查看高速计数是否上增下减、门区开关与设定总楼层是否符合、顶层强迫减速是否有效。
故障代码:30故障说明:安全回路断开,安全回路切断或安全回路继电器触点接触不良。
故障对策:检查安全回路的断开部分;更换安全回路继电器。
三菱电梯LEHY-M 电梯故障代码表
B5 不能开门2分钟
B6 熔断器故障2分钟
B7 #60异常
B8 不能开门
B9 主操作异常
BA MBS ON故障
BB 警报器卡住
BC 轿厢警报器无法操作
BD 群控异常
BE 层站电源异常
BF MBS OFF故障
C1 SLC传输出错
C2 SLC急停
C3 SLC异常高速
C4 SLC失速定时器
A3 驱动软件异常
A5 速度与速度图形比较
A6 手动过电流
A7 MCP逆变器过电流
A8 TSD-PDA故障
A9 MCP整流器过电流
AA MCP初始化异常
AB RAM异常
AC T.M常数异常
AD MCP重启动异常
AE MCP-WDT4次
AF W2板异常
B1 不能使用10分钟
B2 不能使用16分钟
B3 不能重启动10分钟
64 #29安全回路
65 12V电源异常
66 温度异常
67 PLL同步异常
68 整流器过电流
69 过电流
6A 整流器过电压
6B 断电
6C U相过电流
6D V相过电流
6E W相过电流
71 CC-WDT5次
72 CC-WDT4次
73 CC-WDT3次
74 SLC-WDT5次
75 SLC-WDT4次
76 SLC-WDT3次
DB SC-CPU故障
DC SH-CPU故障
DD HS-CPU故障
E1 后门BC-CPU5故障
E2 后门BC-CPU6故障
E3 后门BC-CPU7故障
E4 后门BC-CPU8故障
E5 后门CS-CPU故障
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
故障代码:3
故障说明:变频器未准备好故障,即变频器处于故障保护状态;变频器参数设置不当。
故障对策:根据变频器故障显示检查故障来源;检查变频器输出信号(准备完了)的参数设置。
故障代码:4
故障说明:变频器运行故障,主板输出方向和使能信号,而变频器运行信号(开闸信号R2)没有给定。
故障对策:检查变频器方向和使能端口设置;检查变频器是否没有接收到方向和使能命令;检查EMERSON CT变频器19.15参数是否打得过低(建议值:600-1200)。
故障代码:5
故障说明:编码器信号无反馈故障(编码器故障或电机未转)
故障对策:编码器损坏(配同步主机时,编码器损坏电梯是无法正常开慢车);变频器分频输出部件损坏;高速计数输入接口配线错误;电机堵转。
更换编码器;更换变频器分频卡;检查配线;检查抱闸是否未张开。
故障代码:6
故障说明:编码器信号错相故障(A、B相接反)
故障对策:高速计数的A、B相接反。
调换J16端口A、B相的接线,或调换J17端口的A+与B+,以及A―与B―的接线。
故障代码:8
故障说明:R2短接故障,电梯停止时变频器的运行信号(开闸信号R2)依然存在。
故障对策:检查变频器内参数设置;检查变频器运行信号(开闸信号R2)输出点是否粘连。
故障代码:9
故障说明:电机热保护。
故障对策:电机热保护装置动作。
故障代码:10
故障说明:通讯故障,控制主板与外呼显示板和轿厢主控器不能建立通讯。
故障对策:检查随行电缆的串行通讯电路或接插件有无断线;更换相关控制板。
故障代码:21
故障说明:自学习失败
故障对策:查看高速计数是否上增下减、门区开关与设定总楼层是否符合、顶层强迫减速是否有效。
故障代码:30
故障说明:安全回路断开,安全回路切断或安全回路继电器触点接触不良。
故障对策:检查安全回路的断开部分;更换安全回路继电器。
故障代码:31
故障说明:运行中门锁脱开,门刀位置调整不当;门机保持力不够;门锁接触器触点接触不良。
故障对策:调整门机构;更换门锁接触器。
故障代码:32
故障说明:门锁短接,门锁信号和开门到位信号同时动作。
故障对策:拆除门锁短接线;检查开门到位开关是否有误动作或主板内参数----逻辑二设置是否有误。
故障代码:33
故障说明:快车状态未停在门区。
故障对策:运行中门锁动作、相序动作或变频器保护或其他的保护动作;检修在非门区转为自动。
结合其他故障信息综合判断。
故障代码:35
故障说明:门锁继电器粘连,高压厅、轿门锁监测点未动作但门锁接触器触点动作。
故障对策:更换门锁继电器。
故障代码:36
故障说明:安全继电器粘连,高压安全监测点未动作但安全接触器触点动作。
故障对策:更换安全继电器。
故障代码:37
故障说明:运行超时故障,门区信号丢失、电机堵转或轿厢遇阻引起电梯在非门区高速运行超时。
故障对策:检查门区信号;检查曳引机;检查运行保护时间是否设置过短(电梯存在超长楼层时)。
故障代码:38
故障说明:运行时高压监测厅门锁断开。
故障代码:39
故障说明:运行时高压监测轿门锁断开。
故障代码:40
故障说明:离开门区超时5秒电梯起动后在5秒内还未离开门区。
故障对策:检查抱闸是否打开;检查变频器参数设置是否造成加速过于缓慢。
故障代码:41
故障说明:低速运行超时20秒,电梯减速后20秒还未到达门区。
故障对策:检查变频器减速时间是否设定太短;检查门区开关是否损坏。
故障代码:42
故障说明:顶层、底层强迫减速同时动作。
故障对策:检查强迫减速开关是否损坏;检查强迫减速信号是否断线。
故障代码:43
故障说明:地震输入点动作。
故障代码:46
故障说明:失速,电梯速度大于额定梯速的115%,立即动作。
故障对策:检查变频器是否速度设置过高;重新检查参数设置。
故障代码:47
故障说明:慢车下限位开关动作。
故障对策:限位开关安装偏高,正常运行至底层也会动作。
故障代码:48
故障说明:慢车上限位开关动作。
故障对策:限位开关安装偏低,正常运行至顶层也会动作。
故障代码:50
故障说明:运行接触器闭合动作超时1.2秒故障检测到运行接触器粘连故障。
故障对策:运行接触器粘连;运行接触器辅助触点接触不良。
故障代码:51
故障说明:运行接触器断开动作超时1.2秒故障,检测到运行接触器,在运行后不动作的故障。
故障对策:运行接触器辅助触点接触不良;更换运行接触器;检查运行接触器在主板上的反馈点(P3.0)是否正常。
故障代码:52
故障说明:抱闸接触器闭合动作超时1.2秒故障,检测到抱闸接触器粘连故障。
故障对策:抱闸接触器粘连;抱闸接触器辅助触点接触不良。
故障代码:53
故障说明:抱闸接触器断开动作超时1.2秒故障,检测到运行接触器在运行后不动作的故障。
故障对策:抱闸接触器辅助触点接触不良;更换抱闸接触器;检查抱闸接触器在主板上的反馈点(P3.1)是否正常。
故障代码:54
故障说明:抱闸行程开关闭合动作超时1.2秒故障,检测到抱闸在运行后不能张开的故障。
故障对策:抱闸机械卡死;抱闸行程开关接触不良。
故障代码:55
故障说明:抱闸行程开关断开动作超时1.2秒故障,检测到停车时抱闸没有闸紧故障。
故障对策:抱闸机械卡死;抱闸行程开关接触不良;抱闸线圈的控制电路存在接触不良的点。
故障代码:56
故障说明:厅、轿门锁高压监测点均动作而低压门锁输入点未动作,门锁回路通但门锁继电器没有吸合。
故障对策:更换门锁继电器。
故障代码:57
故障说明:安全高压监测点动作而低压监测点未动作,安全回路通但安全继电器没有吸合。
故障对策:更换安全继电器。
故障代码:60
故障说明:开门受阻不到位超时10秒,电梯开门动作超过10秒,到位开关不见动作。
故障对策:清理门机地坎;门机低速力矩太小,需重新设置门机变频器参数;串行通讯不正常。
故障代码:61
故障说明:关门受阻不到位超时10秒,电梯关门动作超过10秒,到位开关不见动作。
故障对策:清理门机地坎;门机低速力矩太小,需重新设置门机变频器参数;串行通讯不正常。
故障代码:62
故障说明:开关门到位开关同时动作
故障对策:开关门限位开关损坏;开关门到位信号逻辑设置(常开/常闭)设置不对;串行通讯不正常。
故障代码:64
故障说明:安全触板、光幕动作超时10秒以上
故障对策:有人挡住门机;光幕损坏;光幕信号线断线或短路。
故障代码:65
故障说明:停电运行(UPS)运行
故障对策:电梯启动停电应急运行功能;主板上停电运行信号(P4.4)逻辑设置有误。
故障代码:66
故障说明:关门到位门锁不通,关门已到位而门锁不通。
故障对策:调整门机构开关点位置;调整变频门机参数;调换门锁装置。
故障代码:70
故障说明:慢车限位开关同时动作
故障对策:主板上P1.6(S5W)下限位信号和P1.7(S6W)上限位信号同时动作。
故障代码:71
故障说明:中速强迫减速开关同时动作,主板上P1.4(S3W)下中速强迫减速信号和P1.5(S4W)上中速强迫减速信号同时有效动作。
故障代码:72
故障说明:下低速强迫减速开关粘连,电梯离开底层9秒钟内主板上P1.2(S1W)下低速强迫减速信号一直动作。
故障代码:73
故障说明:上低速强迫减速开关粘连,电梯离开顶层9秒钟内主板上P1.3(S2W)上低速强迫
减速信号一直动作。
故障代码:74
故障说明:下中速强迫减速开关粘连,电梯离开底层9秒钟内主板上P1.4(S3W)下中速强迫减速信号一直动作。
故障代码:75
故障说明:上中速强迫减速开关粘连,电梯离开顶层9秒钟内主板上P1.5(S3W)上中速强迫减速信号一直动作。
故障代码:76
故障说明:提前开门输出接触器粘连故障
故障对策:P3.2逻辑设置错误或提前开门输出接触器触点故障。
故障代码:77
故障说明:高速电梯中,强迫开关位置错误,电梯快车下行碰到S1W时的电梯速度超过该强迫减速对应的速度比例(%),电梯报77号故障,反之上行也报77号故障。
(速度比例可以设定,大于100或等于0无效)。
故障代码:79
故障说明:楼层错误保护,在错层时报79号故障,电梯返1楼纠正楼层。
故障代码:84
故障说明:50,52,54号故障连续报5次,停止运行必须手动复位,同时84号故障提示检查接触器线路,要检修复位。