多角度光泽度计使用说明书V初稿模板

合集下载

高精度光泽度仪使用说明书

高精度光泽度仪使用说明书
本说明书适用于本公司多角度和单角度多功能光泽度仪。 说明书中的示例虽然以多角度来说明,但除了角度切换外几乎所有操作都适 用于单角度仪器。
(1) 本仪器属于精密测量仪器,在测量时,应避免仪器外部环境的剧烈变化, 如在测量时应避免周围环境光照的闪烁、温度、湿度的快速变化等。
(2) 在测量时,应保持仪器平稳、测量口贴紧被测物体,并避免晃动、移位; 本仪器不防水,不可在高湿度环境或水雾中使用。
2 . 1开 机. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 2.2关机............................................................................................ . . . . . 3 三、基本操作.............................................................................................3 3.1菜单操作...............................................................................................4 3.2进入主菜单..........................................................................................4 3.3确认提示界面....................................................................................5 3.4输入提示界面....................................................................................5 3.5编辑操作..............................................................................................6 3.6选项操作...........................................................................................6 四、仪器校准.................................................................................................6 4.1仪器校准................................................................................................7 4.2修改校准板参数.....................................................................................7 五 、 测 量 模 式. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 5.1切换测量模式....................................................................................8 5.2基础模式...........................................................................................8 5.3品管模式.........................................................................................10 5.4统计模式.........................................................................................11 5.5连续模式.........................................................................................13 六、数据管理...........................................................................................11 6.1开启关闭储存..................................................................................14 6.2查看记录.........................................................................................14 6.3删除记录.........................................................................................15 七、标样管理...........................................................................................11 7.1开启差值显示..................................................................................15 7.2查看/编辑/删除标样........................................................................15 7.3测量标样.........................................................................................16 7.4创建标样.........................................................................................16 7.5清空标样.........................................................................................16 八、切换角度...........................................................................................17 九、系统设置...........................................................................................17 9.1语言设置.........................................................................................17 9 . 2蓝 牙. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 7 9.3提示音............................................................................................17

多角度光泽度计使用说明书V初稿模板

多角度光泽度计使用说明书V初稿模板

多角度光泽度计使用说明书V4( 初稿)型号: HP-380上海汉谱光电科技有限公司乔辰光编写袁琨审校目录一多角度光泽度计概述................................................ 错误!未定义书签。

二操作说明.................................................................... 错误!未定义书签。

1 开机、测量页面与模式介绍 .............................. 错误!未定义书签。

2 ”主菜单”页面的简要介绍................................ 错误!未定义书签。

3设置......................................................................... 错误!未定义书签。

3.1 时间日期的设置........................................... 错误!未定义书签。

3.2 角度选择 ....................................................... 错误!未定义书签。

3.3 存储器格式化............................................... 错误!未定义书签。

3.4 SD卡.............................................................. 错误!未定义书签。

3.5 校准 ............................................................... 错误!未定义书签。

3.6 模式设置 ....................................................... 错误!未定义书签。

光泽度计作业指导书

光泽度计作业指导书
批准
审核
编制
2、调校与测量或校验操作应在同一环境温度下进行,否则太大的环境温差会带来数值偏移。
3、使用中应避免强光直接照射仪器,以免外界光干扰而影响测量的准确性。
4、内置电池电能耗尽警告标志出现后,若继续使用会造成仪器仅显示“1”或“-1”。此时应对电池进行充电。
Hale Waihona Puke 六、维护与保养:1、整套仪器应存放在干燥、通风、无腐蚀性气体处。
分度值:1GU
示值误差:±2GU
零值误差:1GU
测定度:1GU
测量光斑:36*18mm²
投射角度:60°
主机电源:5*1.2V
主体体积:130*40*80mm³
四、操作步骤:
1、按住“开”键约2秒即开启仪器。
2、摘去防尘罩,将测口置于黑工作板上,约3分钟后,调节“调校”(AMP)按钮,使显示值等于黑工作板上检定值。
2、仪器不用时,应盖好防尘罩。若发现镜面有灰尘或雾气附着,请用镜头纸或吹风球清除。
3、工作板使用前应注意试净表面的污物和雾气,使用后应妥善保存。不要让表面受损而影响测量准确性。
4、仪器长时间不用时,应每个月对机内电池组适量充补电能。
5、仪器用毕,切记关闭电源开关,以免电池过放电而损坏。
6、仪器不可随意拆卸,以免影响仪器精度和造成维修困难。
3、将测量口置于待测部位,仪器显示值即为该部位的光泽度值。若开机时间较长,应复校仪器的示值,以免影响测量的准确性。
4、测量结束后,套上防尘罩,按“关”键即可关闭仪器,放回保护袋中。
五、注意事项:
1、在操作过程中,仪器测口透镜、工作板表面、物品被测面等应保持洁净。否则会引起测量误差和校验不准确。若其表面有雾气、灰尘、污迹,请用镜头纸或软布蘸午睡乙醇擦拭。

光泽度仪操作保养作业指导书[模板]

光泽度仪操作保养作业指导书[模板]

1. 目的
为准确操作、保养测量仪器/量具,确保仪器/量具精密度、精密度在受控状态;以延长仪器/量具使用周期,特制定本作业指导书。

2. 概述
适用油墨、油漆、烤漆、涂料、木制品等表面光泽测量。

3. 术语
4. 操作说明
4.1使用前:首先检查光泽仪是否贴有校验标签,校验有效期是否在校准周期内(如超出校准有效期,
必须送品质部-测试中心外校后再进行使用)。

4.2操作步骤:
4.2.1按下电源开关“红色”按钮,液晶屏有显示,说明已接通电源,仪器开始工作;
4.2.2仪器提示“校准操作”,显示屏显示“CAL”,让仪器测量窗口对准校准板,按一下“黄色”按钮确
认校准操作,仪器自动识别校准板,并自动校准,校准仪器有蜂鸣提示,显示屏显示“CAL OK”,完成校准;
4.2.3完成校准操作,仪器进入测量状态,将仪器放在被测样品上,测量窗口对准被测件,按一下“黄色”
按钮,仪器开始测量,完成测量,显示屏显示被测件表面光泽度值,同时蜂鸣提示,注意样品必须平整;
4.2.4测量后仪器显示MES 60°
4.3操作保养注意事项
4.3.1使用中应避免强光直射,否则影响测量准确性;
4.3.2仪器配带的标准板应保持清洁,请勿用手指触摸表面,表面有污渍,影响测量准确性,可用镜头布
或无水酒精擦拭;
4.3.3电池电能耗尽,仪器显示屏显示“Battery lo”,需要更换电池,打开侧面电池盖,取出电池更换;
4.3.4电池耗尽应该及时更换,否则长时间存放,旧电池有可能流废液,造成仪器损坏,仪器长时间不用,
应取出电池,妥善保管。

5. 相关文件
序号文件名称
6. 记录的保存
7. 文件拟制/修订记录。

光泽仪演示文稿

光泽仪演示文稿

20° 60° 85° 20°60° 60° 85° 20° 60°85°
储存功能
• 此功能能储存多达999个测量值,储存功能 可用于样品测量模式,统计测量模式和连 续测量模式。在一个记忆区中,可以更改 测量模式和标准(目标值),但是不能更 改角度。(具体操作方法请参考技术说明 书)
Save(储存)
图1 镜像光泽度计测量原理 需要注意的是,在整个光泽度测量过程 中,默认光源的光是很稳定的,不会发 生变化。
2.光泽度计的测量方法
• 测量第一步:校准

在使用光泽度计之前,一定要校准仪器,首先,用已知 光泽度值的校准板进行测量,设此校准板的光泽度值为a, 光源发出的光光强为b,光电池检测到的光强度为c。通过 校准过程可知光源光强为:
2.光泽度计测量原理和定标方法
1.测量原理 • 光泽度是在一组几何规定条件下对材料表面反射光的能力 进行评价的物理量。因此,它表述的是具有方向选择的反 射性质。根据光泽的特征,可将光泽分成几类,我们通常 说的光泽是指“镜向光泽”,所以光泽度计,有时也叫镜 向光泽度计。光泽度与机械加工行业的“光洁度”或“粗 糙度”的概念完全不同,后者是对材料表面微小不平度的 评定。 • 光源出射一束光经过透镜L1到达被测面P,被测面P将光 反射到透镜L2,透镜L2将光束会聚到位于光栏B处的光电 池,光电池进行光电转换后将电信号送往处理电路进行处 理,然后仪器显示测量结果。见下图所示:
止如 电果 池长 漏时 液间 进的 而不 损使 坏用 仪测 器量 。主 机 , 请 取 出 电 池 , 防

任洁 能 主 何特 耐 机 酮别 所 底 类的 有 座 溶污 溶 和 剂渍 剂 外 !, 。 壳 请应能 使该耐 用用数 乙柔种 醇软溶 或的剂 清湿。 洁布但 剂来我 。清们 不洁不 要。能 使要保 用清证

上海仪电物理光学仪器有限公司 WGG-268三角度光泽度仪用户手册说明书

上海仪电物理光学仪器有限公司 WGG-268三角度光泽度仪用户手册说明书

上海仪电物理光学仪器有限公司Shanghai INESA Physico optiacal instrument Co.,LtdWGG-268三角度光泽度仪使用说明书本产品根据上海仪电物理光学仪器有限公司企业标准Q31/010*******C064《WGG-268三角度光泽度仪》生产1.仪器用途WGG-268三角度光泽度仪是采用光电反射式工作原理,测定物体表面光亮程度的仪器。

其技术参数完全符合国家标准GB9754-88,国际标准ISO2813《非金属涂料膜20°、60°、85°镜面光泽的测量》,所以适用范围较大;各项性能指标均达到国家计量检定规程JJG696-2002一级工作机的要求。

仪器体积小,重量轻,便于携带;节能,省电;即开即测,无需等待时间,数值稳定,无漂移,便于快速测量。

本仪器适用于油漆、涂料、油墨、石材、纸张、搪瓷、瓷砖、家具、家电、塑料制品、包装装潢等平面制品光泽度的测量。

另外,本仪器还适用的标准:ASTM D523镜面光泽度标准测试方法;ASTMD1455乳胶地板抛光漆的60°镜面光泽度标准测试方法;ASTM D2457塑料薄膜镜向光泽度的标准测试方法;JIS Z8741镜面光泽度测量方法。

2.主要技术参数和规格1测量角度20°、60°、85°2分度值0.1GU3测量范围0-120GU4重复性±0.4GU5示值误差±1.5GU6仪器外形尺寸171㎜×60㎜×93㎜7仪器重量400g3.仪器工作原理光泽度是测量样品表面的光反射能力,其基本原理如下:15324图1其中1是灯泡,2是透镜,3是液晶屏,4是硅光电池,5被测样品4.仪器结构图25.操作步骤及使用方法1.选择投射角度:测量超高光泽样品时,建议选用20度;通用角度一般选用60度;测量超低光泽样品时,建议选用85度。

选择标准为:G(60°)>70光泽单位,建议选用20°角;10≤G(60°)≤70光泽单位建,建议选用60°角;G(60°)<10光泽单位,建议选用85°角。

光泽度计操作指引

光泽度计操作指引

光泽度计操作指引光泽度计是一种用于测量物体表面光亮程度的仪器,广泛应用于塑料、金属、涂料、陶瓷等材料的质量控制和产品检测中。

在正确操作下,光泽度计可以提供准确的光泽度测量结果。

以下是光泽度计的操作指引:1.准备工作:-首先,检查光泽度计是否正常运行,包括电源是否连接好、仪器是否有损坏等。

-检查光泽度计的测试面板是否干净,如有灰尘或污垢,应用清洁布轻轻擦拭干净。

2.样品准备:-将待测样品放置在光泽度计的测试面板上,确保样品与测试面板平整接触,并且没有空气间隙。

-一般情况下,样品的尺寸应大于光泽度计的测量口径,以保证测量结果的准确性。

3.选择测量条件:-根据样品的光泽度级别,选择合适的测量条件,一般有高光、半光和低光模式可供选择。

-高光模式适用于高光泽度的样品,半光模式适用于中等光泽度的样品,低光模式适用于低光泽度的样品。

4.进行测量:-打开光泽度计的电源开关,等待仪器启动并进入待机状态。

-在测量之前,应先进行零点校准。

将光泽度计的测试面板朝向光源,在没有样品的情况下按下零点校准按钮,待仪器显示“0”时,零点校准完成。

-将装有待测样品的测试面板朝向光源,按下开始测量按钮,仪器开始进行测量,并在显示屏上显示测量结果。

5.记录和分析测量结果:-将测量结果记录在相关的文件或表格中,包括样品的名称、测量时间、测量条件和测量值等。

-根据测量结果进行分析和评估,判断样品的光泽度是否符合要求。

6.保养和维护:-定期清洁光泽度计的测试面板和光源,以保持其良好的工作状态。

-避免光泽度计的暴露在湿度高、尘土多或气候恶劣的环境中,以防止仪器受到损坏。

总结:正确操作光泽度计对于获得准确的测量结果至关重要。

在操作之前,需要进行准备工作并选择合适的测量条件。

在测量过程中,要按照操作指引进行,以确保数据的准确性和可靠性。

此外,仪器的保养和维护也是保证仪器长期稳定工作的重要环节。

记住以上操作指引,能够有效地使用光泽度计并得到准确的测量结果。

光泽度使用说明书

光泽度使用说明书

光泽度使用说明书一、简介光泽度是一种重要的表面质量指标,用于评估物体表面的光亮程度。

它通常与表面光滑度、反射率等指标密切相关,是许多行业中对产品质量进行检测和控制的重要参数之一。

本说明书旨在帮助用户了解如何正确使用光泽度仪器,并根据测试结果进行质量评估和质量控制。

二、光泽度测量原理光泽度的测量原理是利用物体表面的反射光线来评估其光亮程度。

光泽度仪器通过发射一束光线至物体表面,并检测所反射回来的光线强度来测量光泽度。

当物体表面光滑且无瑕疵时,反射光线的强度较高,表明光泽度较高;相反,当表面有瑕疵或不光滑时,反射光线的强度较低,表明光泽度较低。

三、光泽度测量步骤1. 准备工作- 确保光泽度仪器处于正常工作状态,并已校准好;- 将待测样品放置在无反光的平整表面上,并确保表面无污垢和指纹;- 保持测量环境的稳定,避免干扰因素影响测量结果。

2. 开始测量- 打开光泽度测量仪器的电源并等待预热;- 将仪器的传感器靠近待测样品表面,保持一定的测量距离;- 确保仪器与样品表面垂直保持一定角度,并保持稳定;- 按下测量按钮进行测量,并等待测量结果显示。

3. 结果分析与评估- 根据测量结果,确定样品的光泽度数值;- 根据产品要求或行业标准,判断光泽度数值是否符合需求;- 如果光泽度数值较低,检查样品表面是否有污垢或瑕疵,并及时清洁与修复;- 如果光泽度数值较高,检查样品表面是否过于光滑或过度处理,并适当减少处理步骤。

四、注意事项- 在测量过程中,避免用手触摸样品表面,以免留下指纹或污垢影响测量结果;- 确保仪器与样品表面平行,并保持适当的测量角度,以获得准确的测量结果;- 定期对光泽度仪器进行校准和维护,以确保测量结果的准确性和可靠性;- 选择合适的测量环境,避免光线和其他干扰因素对测量结果产生影响;- 在测量前,对待测样品进行适当的处理和准备,保持样品表面的整洁和光滑。

五、总结光泽度作为一项重要的表面质量指标,对于许多行业中产品的制造和质量控制具有重要意义。

光泽度计怎么使用方法

光泽度计怎么使用方法

光泽度计怎么使用方法
使用光泽度计的方法如下:
1. 准备工作:确保光泽度计的电源充足,并确保测量区域干净、无杂质。

2. 校准光泽度计:在使用前,需要校准仪器以确保准确性。

根据具体型号的指南,采用校准板或标准样品进行校准。

3. 准备样品:将待测样品放置到测量区域。

对于不同类型的表面,可能需要进行特殊处理,如清洗、抛光等。

4. 测量光泽度:将光泽度计的测量头放置在样品上,并按下测量按钮,在几秒钟内完成测量。

确保测量头与样品表面接触紧密。

5. 记录测量结果:根据光泽度计的显示,记录光泽度的数值。

继续对其他区域或不同样品进行测量,以获得更多的数据。

6. 分析测量结果:根据测量结果,分析样品的光泽度特征。

可以进行比较、统计或进一步处理数据。

7. 清洁和保养:使用完毕后,清洁测量头和仪器表面,并妥善保管光泽度计,以确保下次使用时仍然保持准确性。

请注意,具体的使用方法可能会因光泽度计型号和制造商而有所不同,建议先仔细阅读设备的用户手册或联系制造商获取详细的使用指南。

光泽仪使用说明书-CE marking compliant ig-320 ig-331

光泽仪使用说明书-CE marking compliant ig-320 ig-331

CE marking compliantGLOSS CHECKERIG-320IG-331IG SeriesHigh-efficiency and flexibility utilizing a separate detector and light source offers the ability to switch between 60 and 20degree measuring angles.IG-331High-precision measurements with an integral light source and detector lets the user gather and view averaged data.IG-320CE marking compliantHold keyPower ON key Power OFF keyCalibration keyMeasuring partProtective cap(with standard surface for calibration)60° selection key20° selection keyJust press the calibration key (CAL) to start automatic, sequential zero-span calibration.High-Efficiency Measurements Enables Easy Switching of Measuring Angles (60° and 20°)IG-3316(6 mm x 3 mm oval) at 60° measurementThe flexible, remote connection of the probe to the display unit ensures greater work efficiency and safety in all applications.I Choose 60° for standard glossmeasurements. For high-gloss surfaces with gloss values over 70, simply switch to the 20° measuring angle. The selectable angle feature makes it easy to measureglossy surfaces.Versatile applicationsG Quality control of paint and inkG Check and diagnosis of coated surfacesG Checking printed matterFor quality testing,outdoor exposure testing, hue adjustment or luster testing.Check external coating, cleaning or waxing condition of vehicles, shops, aircraft, bridges, iron/steel frames, and structures or prefabricated structures, etc., and diagnosis of deterioration.of time-induced change and uniformity of surface after drying process; checking paper surface condition.Handy Digital Gloss Checkers Allow Objective,Quantified Gloss MeasurementsDesigned for greater ease of operation, maintain clean surfaces and improve quality control inspection in various industrial applications.One-Touch CalibrationSelectable Measuring Angle (60° or 20°)Light source DetectorLensLensSample surface60°60°Guaranteeing uniform production quality and standards for gloss mesurement. HORIBA’s IG Series Gloss Checkers display glossmeasurements as numerical data, eliminating ambiguity and ensuring objective evaluation of a product’s quality. Compact in design and ready when powered on, all the user needs to do is hold the portable gloss checker against the surface being evaluated for quality control of paints, polishes, floor maintenance and many other industrial applications.Data input keyUp keyAverage keyPower ON key Power OFF key Mode select key(measurement/memory)Data delete keyCalibration keyProtective cap(with standard surface for calibration)Measured areaDown key I Gloss Checker IG-320 Optical SystemThe combination of the near infrared ray pulse system, virtually unaffected by ambient lights or colors, and HORIBA ’s proprietary measuring system provides a high-precision gloss checking system compatible with JIS standards.Up to 99 measurements can be taken with a simple key operation and averaged using another key. Up to 99 averages can be stored for later use. Easy data management promises smooth inspection work.High-Precision MeasurementsLets Users Gather Data or View Averageswith a Single Key OperationIG-320The compact, lightweight design is ideal for production line and outdoor applications.Display of data item No.01Display of data item No.99Display of average of all 99 data itemsUp to 99 averages (AVERAGE No. 99) can bestored by repeating two simple steps.G G Checking external appearance of plastic moldingFor checking external appearance of molded resin products andevaluating weather resistance.G Other usesFor checking quality and external appearance of film, tape, rubber, leather, etc.G Floor maintenance needsstores.High-Precision Measurements with ±0.5% Full-Scale ReproducibilityGather Data or View Averages with a Single Key OperationOptical systemMeasuring area Light source Detector Measuring range Display range Reproducibility Power sourceContinued use time Ambient conditions DimensionsMass Additional FunctionsIncident angle 60° Reception angle 60°12 mm x 6 mm oval LED (wavelength: 880 nm)SPD (silicone photodiode)0-100.00-199.0 (resolution: 0.1)±0.5% F.S. ±1 digitS-006P dry battery (9VDC) for operation, CR-2025 lithium battery (3VDC) for memory 15 hours or more 0-40:78 (W) x 189 (H) x 58 (D) mm 3.1 (W) x 7.4 (H) x 2.3 (D) inApprox. 400g (with battery)Automatic calibration Automatic power cut-off Display holdOverrange display Battery alarmBuilt-in data memory (max. 99)Computation of averages Keystroke confirming toneIG-32060° measurement: Incident angle 60°Reception angle 60°20° measurement: Incident angle 20°Reception angle 20°60° measurement: 3 x 6 mm oval 20° measurement: 3 x 4 mm oval LED (wavelength: 890 nm)SPD (silicone photodiode)0-1000-199 (resolution: 1)±5% F .S. ±1 digit A3 dry-cell battery x 4Not rechargeable50 hours or more 10-40:Main body: 140 (W) x 75 (H) x 34 (D) mm5.5 (W) x 3.0 (H) x 1.3 (D) in Optical system: 88 (W) x 30 (H) x 45 (H) mm3.5 (W) x 1.2 (H) x 1.8 (H) inApprox. 350g (with battery)Automatic calibration Automatic power cut-off Display holdOverrange display Battery life displayAccessory Protective cap (with standard surface for calibration)Note: Use the 20° measurement mode of the IG-331 when the gloss value in the 60° measurement mode exceeds 70.I SpecificationsHoriba continues contributing to the preservation of the global environment through analysis and measuring technology.ISO 14001 JQA-E-90039 (Head Office/Factory)ISO 9001 JQA-0298Award of CertificationG The contents of this catalog are subject to change without prior notice, and without any subsequent liability to this company.G The color of the actual products may differ from the color pictured in this catalog due to printing limitations.G It is strictly forbidden to copy the content of this catalog in part or in full.G All brand names, product names and service names in this catalog are trademarks or registered trademarks of their respective companies.G HORIBA, Ltd.Head OfficeMiyanohigashi, Kisshoin Minami-ku, Kyoto, Japan Phone: 81 (75) 313-8123Fax: 81 (75) 321-5725Tokyo Sales Office 1-7-8 Higashi-KandaChiyoda-ku, Tokyo, Japan Phone: 81 (3) 3861-8231Fax: 81 (3) 3861-8259G HORIBA KOREA L t d .112-6 Sogong-DongChoong-ku, Seoul, Korea Phone: 82 (2) 753-7911Fax: 82 (2) 756-4972G HORIBA INSTRUMENTS INCORPORATEDIrvine Facility17671 Armstrong AvenueIrvine, CA 92614, U.S.A.Phone: 1 (949) 250-4811Fax: 1 (949) 250-0924Ann Arbor Facility 5900 Hines Drive Ann Arbor, MI 48108U.S.A.Phone: 1 (734) 213-6555Fax: 1 (734) 213-6525Leichlingen FacilityJulius-kronenberg Strasse D-42799 Leichlingen GermanyPhone: 49 (2175) 8978-0Fax: 49 (2175) 8978-50G HORIBA / STEC INCORPORATED 1080 E. Duane, Suite. A Sunnyvale, CA 94086U.S.A.Phone: 1 (408) 730-4772Fax: 1 (408) 730-8975G HORIBA INSTRUMENTS LIMITED Kyoto CloseSummerhouse RoadMoulton Park, Northampton NN3 6FL, U.K.Phone: 44 (1604) 542500Fax: 44 (1604) 542699G HORIBA INSTRUMENTS Pte. L TD.10 Ubi Crescent#05-11/12, Ubi Techpark Singapore 408564Phone: 65 6745-8300Fax: 65 6745-8155G HORIBA EUROPE GmbH Head Office Hans-Mess-Str.6D-61440 Oberursel/Ts.GermanyPhone: 49 (6172) 1396-0 Fax: 49 (6172) 137385HORIBA FRANCE12, Avenue des Tropiques 91955 LES ULIS FrancePhone: 33 (1) 69-29-96-23Fax: 33 (1) 69-29-95-77G HORIBA GmbH Kaplanstrasse 5A-3430 Tulln, AustriaPhone: 43 (2272) 65225Fax: 43 (2272) 65230HORIBA CZECHIAOrganizachi slozka Praha Petrohradska 13CZ-101 00 Praha 10, Czech Republic Phone: 420 (2) 717-464-80Fax: 420 (2) 717-470-64HORIBA SWEDEN Sydhamnsvägen 55-57,SE-151 38 Södertälje, SwedenPhone: 46 (8) 550-80701Fax: 46 (8) 550-80567HORIBA ITALY EuropalaceCorso Torino 43/4510043 Orbassano,Torino,Italy Phone: 39 (011) 9040601Fax: 39 (011) 9000448Bulletin:HRE-3313APrinted in Japan ZR-TF(SK)33e-mail:**************.jpTAIWAN Representative Office 3F, NO.18 Lane 676, Chung Hua Rd, Chupei City,Hsinchu Hsien, 302,Taiwan Phone: 886 (3) 656-1012Fax: 886 (3) 656-8231G HORIBA TRADING (SHANGHAI) CO., Ltd.Shanghai OfficeRoom 1103, United Plaza,1468 Nanjing Rd. West,Shanghai, 200040, China Phone: 21-3222-1818Fax: 21-6289-5553Beijing Office Room 609, Jin Bao Plaza,89 Jin Bao Street, Dongcheng District, Beijing,100005 China Phone: 10-6522-7573Fax: 10-6522-7582。

GM系列光泽度计使用说明书

GM系列光泽度计使用说明书

光泽度计本仪器体积小,重量轻便于携带,方便使用和操作。

为了确保正确使用,请仔细阅读此说明书的信息,并按照说明书所提供的信息进行操作使用。

3-1 显示器3-2 测量键3-3 删除键3-4 读取键GM-04 GM-071.仪器特性* 本产品的设计和生产符合国际A S T M D-523,A S T M D1455,A S T MC346,A S T M C584,A S T M D2457,ISO2813,DIN67530,ENISO7668,JISZ8741,MFT30064,TAPPIT480,GB9754,GB/T13891,GB7706和GB 8807标准。

技术参数符合JJG 696-2002的标准。

* 光泽计有各种不同的测量角度。

通常,20°适用于高光泽材料,60°适用于中光泽材料,85°适用于低光泽材料。

另外有两种角度适用于其他材料。

45°专门用于测量陶瓷、薄膜、纺织品和阳极氧化铝的光泽度,而75°专用于测量纸张和印刷材料的光泽度。

* 测量准确,重复性好。

* 具有电源欠压指示功能。

* 全智能化设计,快速测量。

* 操作使用中有蜂鸣声提示。

* 可以储存254组最新的测量数据。

* 精密,轻巧的外形,携带方便自动校准,无需手调。

2.技术参数准确度:±1.0(相对于参考标准)分辨率:0.1重复性:±0.5GU稳定性:小于±0.4GU/30Min光度单位:GU测量范围:0~200GU示值误差:小于±1.2GU投射角度:GM-04: 45°GM-07: 75°GM-247: 20°/45°/75°数值记忆:254组测量面积:7x14mm(椭圆)环境温度:0~40°C相对湿度:不超过85%电源:3.7V锂电池尺寸:140x45x75mm重量:约305g(包含电池)标准配置:主机..................1台光学清洁布............1块校准标准片............1块电源适配器............1个手提便携箱............1个使用说明书............1份可选配件:USB联机线和软件蓝牙Bluetooth数据输出3.面板说明3-5 电源键3-6 角度转换键3-7 校准键4.关机和关机按住“3-5电源键”开机;本机采用充电;一般充电时间大约四小时。

光泽度计操作指引

光泽度计操作指引

光泽度计操作指引一、目的:为准确检测送检物料的光泽度,使测量值成为生产用料和质量判定之正确依据,特制定本作业指导书。

二、范围:各类经过表面处理的产品均属之。

三、测试标准:3.1哑胶:3-15度3.2过油:≧40度3.3过UV:65-90度3.4磨光:≧70度3.5光胶:75-90度四. 权责:4.1一般情况下光泽度计之使用、保管与校正--------表面处理IPQC、FQC4.2异常质量情况下之使用、保管与校正---------QE4.3由仪器校正员按正常作业步骤作内校,因技术无法达到校正之要求申请外校。

五. 操作步骤:5.1仪器使用条件:环境温度0-40摄氏度,相对湿度不超过70%,可连续工作10小时(当显示屏上显示“LOBAT”时,应立即充电。

)5.2测量:5.2.1开机预热:按下仪器电源开关,同时使“测量/保持”按纽处于测量位置,使仪器预热2分钟。

5.2.2校标:把仪器的测量窗口置于黑色标准板上,仪器外壳上的“V”标记对准标准板上的刻线,观察液晶显示板,待显示数据稳定后,再通过“校标”旋钮把数值调整至标准板所标定的数值。

(顺时针旋转为增加,反时针旋转为减小,黑色高光泽度面板标准为95.8度,白色/低光泽度面板标准为24.5度),一般使用30分钟后要重新校标一次。

5.2.3线性校正:经校标后的仪器放在光泽度标准板上,观察显示数值与标准值的差异是否在±1.2度范围内,如果数值低于标准值±1.2时,则标准板表面可能有汗迹,可用橡皮擦拭后再重新较正。

5.2.4测量及数据保持:把校正好的仪器放在待测物上进行测量,在测量数值稳定后,按下“测量/保持”按钮,则测量值就会保持在显示屏上,再按下该按钮就可重新进行测量。

一般取5个测量点的平均值作为测量值。

光泽度计使用方法

光泽度计使用方法

光泽度计使用方法
嘿,朋友们!今天咱就来讲讲这光泽度计的使用方法。

这光泽度计啊,就像是我们探索光泽世界的小魔杖!
拿到光泽度计,先别急着用,得好好瞅瞅它,就像认识一个新朋友一样。

看看它的各种按钮、接口啥的,心里有个数。

然后呢,找个要测量的东西,把光泽度计轻轻地放上去,就好像给它一个温柔的拥抱。

这时候,你就等着它给你显示出那个神奇的数字啦!那个数字就像是在告诉你这个东西的光泽秘密呢。

可别小瞧了这个数字,它能告诉你很多信息哦!
你想想,要是没有光泽度计,我们怎么能准确知道一个东西的光泽度到底咋样呢?它就像是我们的眼睛,帮我们看到那些我们自己看不到的东西。

测量的时候,要注意保持稳定哦,别手抖得像筛糠一样,不然测出来的结果可就不准确啦!就好像走路,你得稳稳当当的,不然不就摔跟头了嘛。

而且哦,不同的材料可能需要不同的测量方法和角度呢。

这就好比每个人都有自己的脾气,得顺着来。

你不能用测木头的方法去测玻璃呀,那肯定不行的。

还有啊,用完了光泽度计可得好好保管,别乱丢乱放,不然下次要用的时候找不到了,那不就傻眼了嘛。

总之呢,光泽度计是个很神奇的小工具,只要我们好好用它,就能让它发挥出大作用。

它能让我们更了解这个充满光泽的世界,让我们的生活更加丰富多彩。

所以啊,大家可别小看了它哟!。

多了解一下多角度镜向光泽度仪的使用 光泽度仪如何操作

多了解一下多角度镜向光泽度仪的使用 光泽度仪如何操作

多了解一下多角度镜向光泽度仪的使用光泽度仪如何操作光泽度仪校准是光泽度测量中紧要的一环,由于光泽度仪校准是否精准会直接影响到测量结果,下面我们以3nh光泽度仪NHG268校准步骤来演示光泽度仪校准。

光泽度仪校准是光泽度测量中紧要的一环,由于光泽度仪校准是否精准会直接影响到测量结果,下面我们以3nh光泽度仪NHG268校准步骤来演示光泽度仪校准。

多角度镜向光泽度仪使用方法;1.按下仪器的开关键,液晶显示屏为00.0(各角度处于关段状态)。

2.选择投射角度:测量超高光泽样品时,建议选用20度。

通用角度一般选用60度。

测量超低光泽样品时,建议选用85度。

3.打开标准板盒将仪器测量口放在黑玻璃标准板上(切记将主机测量口对准标准板中心)。

4.定标: 调整仪器的校正旋钮,使显示屏的读数符合黑玻璃标准板上对应角度的标定值。

(为保证测量精准度,黑玻璃必需保持干净)5.校正: 将定标后的仪器(注意不要碰动定标旋钮)。

放在另一个标准盒的白色陶瓷工作板上,此时显示屏显示的值应与白色陶瓷工作板标定值之差不大于1.5GS。

6.测量: 将仪器放在被测样品上,显示屏显示的读数即为该样品在该角度下的光泽度值。

被测样品必需为平面制品。

多角度镜向光泽度仪使用方法的维护及注意事项1.使用中应避开强光直射,否则影响测量的精准性。

2.仪器配带的标准板应保持清洁,切勿用手指触摸表面。

如表面有污渍,会导致仪器误差加大及读数不精准,可用镜头纸和脱脂棉沾无水乙醇擦拭。

本仪器电池使用到3.6v以下时读数开始下滑,仪器显示屏左下角显现“←”提示操需要充电,将充电器接上充电直到仪器充电指示灯由红变绿为止。

(此时表示仪器充电完毕),否则影响测量精度。

当仪器使用环境发生变化时(比如温度、海拔、湿度等猛烈变化时),仪器确定要进行校准。

为确保校准的精准明确,请使用原厂供应的标准板。

标准板上的灰尘会影响校正效果,校准前,请用擦拭布擦拭标准板工作面,确认工作面干净。

光泽度仪的使用说明

光泽度仪的使用说明

光泽度仪的使用说明一、引言光泽度仪是一种用于测量物体表面光泽度的仪器。

它通过照射光源并测量光的反射情况,来评估物体的表面光滑度和反射能力。

本文将详细介绍光泽度仪的使用方法,帮助用户正确使用该仪器。

二、仪器准备在使用光泽度仪之前,需要确保仪器处于正常工作状态。

首先,检查仪器的电源是否连接正常,并保证电源电压符合要求。

其次,检查光泽度仪的光源是否正常发光,并检查传感器是否处于灵敏状态。

最后,检查仪器的控制面板和显示屏是否正常工作,确保用户可以正常操作。

三、样品准备在进行光泽度测量之前,需要准备待测样品。

样品应处于干燥、清洁的状态,以确保测量结果准确。

如果样品表面有灰尘或污垢,应先进行清洁处理。

此外,对于不同类型的样品,还需根据其特性选择合适的测量模式和参数。

四、测量步骤1. 将样品放置在光泽度仪的测量台上,保证样品表面与仪器的传感器接触良好。

2. 打开光泽度仪的电源,待仪器启动完成后,进入测量模式选择界面。

3. 根据样品的特性选择合适的测量模式:如高光泽度模式、低光泽度模式、颜色模式等。

根据需要,还可以设置测量参数,如光源强度、测量角度等。

4. 确定好测量模式和参数后,点击开始测量按钮,仪器会自动开始测量。

在测量过程中,保持样品和仪器的相对位置稳定,避免外界干扰。

5. 等待测量完成后,仪器会显示测量结果。

用户可以通过仪器的显示屏或连接的电脑软件查看结果。

同时,仪器还可以提供统计分析功能,如平均值、最大值、最小值等。

五、结果解读根据光泽度仪显示的测量结果,用户可以对样品的光泽度进行评估。

一般而言,光泽度值越高,表示样品表面越光滑、反射能力越强;反之,光泽度值越低,表示样品表面越粗糙、反射能力越弱。

用户可以根据具体需求,对不同样品的光泽度进行比较和分析。

六、注意事项1. 在使用光泽度仪时,避免将光源直接照射到眼睛,以免对眼睛造成伤害。

2. 定期检查仪器的光源和传感器是否正常工作,如发现异常应及时进行维修或更换。

光泽度仪作业指导书

光泽度仪作业指导书
0 6
记录测量结果,以便后 续分析和改进。
03 使用后注意事项
关闭光泽度仪开关
01
02
03
04
关闭光泽度仪开 关,避免长时间 使用造成仪器损 坏。
关闭电源,避免 浪费电能。
清洁仪器表面, 保持仪器清洁。
将仪器放回原位, 避免丢失。
将样品取下并清理测量台
01
02
03
04
测量完成后,将 样品从测量台上 取下。
准备待测样品,确保样品表面干 净、无污渍。
启动测量程序,按照提示进行测 量。
确认光泽度仪已正确安装并 连接电源。
确认仪器状态正常,如出现 异常情况,请及时联系售后。
将样品放置在光泽度仪的测量 平台上,调整样品位置,使样 品表面与测量平台保持平行。
测量完成后,记录测量结果, 并关闭光泽度仪开关。
选择测量模式
确认仪器的校准证书 是否有效,是否需要
重新校准
确认仪器的操作系统 是否正常,是否需要
更新或修复
确认仪器的测量范围 和精度是否符合要求
确认仪器的测量环境 和条件是否符合要求
确认仪器是否在有效期内
检的电源和 电池状态
确保仪器的配件和 附件齐全
记录测量数据, 进行数据分析
和评估
记录测量结果
0 1
测量前,确保光泽度仪 已校准并处于正常工作 状态。
0 4
记录测量结果,包括测 量值、测量时间和测量 环境等信息。
0 2
将光泽度仪放置在被测 样品上,确保测量点均 匀分布。
0 5
对比测量结果与标准值, 判断样品是否符合要求。
0 3
按下测量按钮,等待测 量结果。
Simple & Creative

光泽度仪操作说明

光泽度仪操作说明

文件编号一.图示说明:1.模式滚轮:用来打开仪器和菜单选择2.引导用户使用和显示测量值的显示屏3.绿色灯:实施测量指示;红色时:出错4.操作按钮:用来实施测量5.保护底座
6.定标标准板
7.测量位置标志
8.连接计算机的接口
二.光泽度仪使用方法
三.四.制(修)订日期2010-5-31
页 次 1 OF 1XXXXX
标题
仪器操作说明HH/ZC06-08版 次B/0仪器名称光泽度仪制 定品管部4.2 光泽度标准及差值,以客户要求为准.2.1 仪器应放在保护底座中,当按下(模式滚轮) 时,仪器会进行自动检测,检测合格显示OK.
2.2 按两下(模式滚轮) ,进入主菜单模式(Main menu).
备注
2.8 将产品光泽度标准与所量测实际值进行比较.判定产品实际值是否正确.
注意事项
3.1 切勿将仪器跌落在地,应避免碰撞和挤压.
4.1 所量测的角度选择,以客户要求为准.
2.3 滚动(模式滚轮) ,可将黑条移动到角度选择(Gemetry),按下(模式滚轮) 进入选择菜单.
2.4 滚动(模式滚轮) ,可将黑条移动所需角度上,按下(模式滚轮) 选中所需的角度.
2.5 此时显示屏为主菜单模式(Main menu),再按下(模式滚轮) ,进入量测界面.
2.7 将仪器下端量测口平放在所测样品上,按下仪器侧面的(操作按钮)即可对所测样品表面光泽进行量测.
3.2 把持仪器时,请勿用手接触测量口,应避免任何外部物体进入测量口.
3.3 请勿将仪器长时间地暴露在直射日光中,勿将仪器放置在高温和多灰尘的环境中,不用时请装入盒内.
3.4 仪器只能用乙醇或清洁剂进行清洁.
2.6 此时显示屏显示出所选的角度标准,将仪器从保护底座中取出.。

光泽度计操作说明书

光泽度计操作说明书
+1mil
MEMORY 5E
”或“
”键将屏幕显示数字调整为标准版上的标准化“91.0 ”。
1.2.3 按“OFF”键关机。
W≤10R 0R L≤20R
應華精密表面處理(蘇州)有限公司
管理评审会议召 管理评审计 管理评审输 管理评审 评审实施计划 结 开 管理评
R
W≤10R L≤20R
文件編號 頁 次 版 本 生效日期 2/2 B 2007.6.10
光澤度計操作說明書
一、操作步驟 1.1 开机:按仪器上“ON”键即可。 1.2 设定标准值:
1.2.1 先探位“Standard value input button”键,再按“DATAIN”键,屏幕 显示 1.2.2 按“ 1.3 校正: 1.3.1 给仪器且安装上防护盖,防护盖应准确地盖住两边。 1.3.2 按仪器上“ON”键开机。 1.3.3 按住“CAL”键,同时按“DATA IN”键。屏幕首先会显示“CAL”,接着 显示“91.0”。 1.3.4 取下防护盖,仪器即开始测试。 1.4 测量 1.4.1 将仪器测量孔对准被测部品表面,并平放于上,此时屏幕上显示的数据即 为被测部品的光泽度值。 1.4.2 按“DATA IN”键即可储存显示数据和数据号码。 1.4.3 重复上述动作即可进行多次测量。 1.5 关机:测量完毕后,按仪器上的“POWER OFF”键关闭仪器。 二、注意事项: 2.1 如仪器较长时间没有使用或更换电池后,需重新设定标准值和校正。 2.2 每次测量前应进行校正。 2.3 为保证测量结果的精确,应将仪器放在被侧部品较平坦的部位测试。 2.4 仪器不能放置在过多灰尘或过于潮湿的地方。 三、保養及維護 3.1 仪器应避免受到震动、磨擦、过度挤压、划伤等。 3.2 不能用手或脏污的物体触摸仪器上的镜片和防护盖上的标准板,如有脏物则用 柔软的棉布擦拭。 3.3 仪器不能长时间暴露在阳光下。

光泽度仪作业指导书

光泽度仪作业指导书

光泽度仪作业指导书一、简介光泽度仪是一种用于测量材料表面光泽度的仪器。

它可以定量地测量材料表面的反射光强度,从而评估材料的光泽度或光亮度。

光泽度通常被认为是材料表面光线反射能力的指标,对于许多行业的质量控制和产品表面处理至关重要。

本指导书将介绍光泽度仪的基本操作和有效使用的技巧。

二、光泽度仪的基本操作1. 准备工作在使用光泽度仪之前,确保仪器处于良好的工作状态。

检查仪器的电源线是否连接正常,设备表面是否干净无尘。

如果有残留物,可以使用干净的布轻轻擦拭。

2. 校准仪器在每次使用光泽度仪之前,都应该进行校准,以确保测量结果的准确性。

校准操作通常包括将仪器放置在标准参考样品上,按照仪器说明进行调整。

3. 测量操作将待测样品放在光泽度仪的测量台上,确保样品表面无明显污染或划痕。

点击仪器上的测量按钮,光泽度仪会发出一束光,照射在样品表面。

仪器会自动记录反射光强度,并将结果显示在仪器的屏幕上。

4. 分析结果将光泽度仪测得的光泽度数值与标准参考样品进行比较,评估材料的表面光泽度。

根据需要,可以使用仪器自带的数据分析软件,对测量结果进行显示、存储和处理。

三、注意事项1. 避免外界光干扰在测量过程中,应尽量避免外界光源的影响,以确保测量结果的准确性。

可以在实验室或较暗的环境中进行测量,并关闭周围的光源。

2. 规避人为因素在放置样品的过程中,避免直接用手触摸样品表面,以免留下指纹或污染样品。

使用干净的手套或工具来操作样品,保持样品表面的干燥和清洁。

3. 定期进行校准光泽度仪的准确性与校准程度密切相关。

为了获得准确的测量结果,建议定期进行仪器的校准操作,确保仪器的准确性和性能稳定。

4. 注意样品的选择不同的材料表面具有不同的光泽度特性,因此在选择样品进行测量时,应注意选择适合的参考样品。

根据所需测量的光泽度范围,选择与之相应的标准样品。

四、常见应用领域光泽度仪在许多行业中都有广泛的应用。

以下是一些典型的应用领域:1. 汽车制造业:用于评估汽车表面涂层的质量,追踪生产线上的缺陷,并帮助改进涂料配方。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

多角度光泽度计使用说明书V4( 初稿)
型号: HP-380
上海汉谱光电科技有限公司
乔辰光编写
袁琨审校
目录
一多角度光泽度计概述................................................ 错误!未定义书签。

二操作说明.................................................................... 错误!未定义书签。

1 开机、测量页面与模式介绍 .............................. 错误!未定义书签。

2 ”主菜单”页面的简要介绍................................ 错误!未定义书签。

3设置......................................................................... 错误!未定义书签。

3.1 时间日期的设置........................................... 错误!未定义书签。

3.2 角度选择 ....................................................... 错误!未定义书签。

3.3 存储器格式化............................................... 错误!未定义书签。

3.4 SD卡.............................................................. 错误!未定义书签。

3.5 校准 ............................................................... 错误!未定义书签。

3.6 模式设置 ....................................................... 错误!未定义书签。

4模式选择................................................................. 错误!未定义书签。

5基本测量模式页面................................................. 错误!未定义书签。

6采样测量页面......................................................... 错误!未定义书签。

6.1采样测量的操作流程.................................... 错误!未定义书签。

6.2查看采样记录的操作流程............................ 错误!未定义书签。

7统计测量页面......................................................... 错误!未定义书签。

7.1 选择标样与设定容差................................... 错误!未定义书签。

7.2 统计测量流程............................................... 错误!未定义书签。

8连续测量页面......................................................... 错误!未定义书签。

9 USB与蓝牙的设置................................................ 错误!未定义书签。

9.1 USB的使用 ................................................... 错误!未定义书签。

9.2 蓝牙的使用 ................................................... 错误!未定义书签。

三: 特殊情况的处理....................................................... 错误!未定义书签。

一多角度光泽度计概述
光泽度计使用须知:
1、本说明书所述”光泽度计”指的是镜向光泽度计或镜面光泽度计, 也称”光泽计”。

2、本说明书所述”工作板”指与光泽度计配套, 用于仪器校准的工作标准器件。

3、本仪器使用应避开强电磁干扰。

HP-380符合用标准:
1、ISO2813, ISO7668
2、ASTM D523, ASTM D2457
3、GB/T 9754, GB/T13891, GB/T7706, GB/T8807
HP-380各项性能指标均达到国家JJG 696- 《镜向光泽度计和光泽度板》计量检定规程中一级工作机的要求。

HP-380广泛应用于:
油漆涂料、装潢材料、建筑材料、塑胶材料、竹木制品、
陶瓷制品、皮革制品、薄膜纸张、印刷油墨、汽车养护、
成型模具等众多领域的材料和制品表面的光泽测量。

光泽度计功能描述:
1、多角度一键完成测量: 一次按键操作可同时完成三角度的测量。

测量光入射角度符合ISO 2813规定的三种测量光入射角度。

镜向光泽度计三个入射角分别为20°、60°、85°。

2、可选角度模式: 测量角度或角度组合可按用户需要选择。

3、人性化设置显示界面。

4、海量存储功能: 本机在三角度模式下, 可累计存储900次测量数
据, 或30组分组数据。

5、数据浏览功能。

6、本机具有低电能提示功能, 存储数据空间满提示功能。

附件描述:
1、电源: 标准+5V外接电源。

空载电压+5.3V。

2、标准板: 该板为光泽度计自诊断标准板, 该板另一功能为仪器提
供自校准用。

3、USB线: 与上位机提供通信用连接线。

4、光盘: 光盘里的软件, 为本仪器配套的上位机软件。

可选件描述:
1、SD卡: 本机提供外接SD卡存储功能。

2、 微型打印机: 本机器支持测量结果的打印功能。

( 连续测量模式没有打印功能)
二 操作说明
1 开机、 测量页面与模式介绍
把光泽度计放到底座上, 然后打开开
关开启机器。

机器进行自动校准。

如图1所示。

按下”确认”键, 进入测量页面。

测量页面的测量模式是之前关机时
的测量模式。

机器被格式化后, 开机启动自动进入基本模式页面。

如图2 所示。

图1
图2
在测量页面下按”确认”键, 系统进入
主菜单。

如图3所示。

”>” 符号的说明:
1选中”主菜单>”按”确认”键进入
测量模式;
2选中除主菜单外的所有含有”>”的选
项, 按”确认”键能够返回上一级主
菜单。

图3
2 ”主菜单”页面的简要介绍
*将光标移至”主菜单> ”后按”确认”键, 能够进入测量页面。

*将光标移至”采样记录”后按”确认”键, 能够查看某个标样下的统计测量记录。

*将光标移至”标样/容差”后按”确认”键, 能够选定标样和该标样下的容差。

*将光标移至”设置”后按”确认”键, 能够设置系统的参数。

*将光标移至”模式选择”后按”确认”键, 能够选择”基本模式”、”采样模式”、”统计模式”和”连续模式”四种测量模式中的一种。

*将光标移至”USB传输”后按”确认”键, 能够与上位机进行数据传输。

*将光标移至”蓝牙传输”后按”确认”键, 能够与上位机进
行无线数据传输。

3设置
进行时间日期、采样角度、校准、存储器格式化、模式设置、SD 卡的设置。

如图4 所示。

图4。