RJG压力传感器ppt课件

合集下载
  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

Mold Closing
Mold begins to Mold clamps up Cycle time with mold opening (Resets Piezo Adapter and
close
UMPI)
Mold Open
Mold fully open Mold begins to Cycle time and integration limit (Resets Piezo Adapter
7
Interfacing the eDART™ with Your Machine
8
Interface Modules
35mm DIN rail mountable modules
Module
Function
ID7-D-SEQ Seven sequence digital input module (universal voltages). Gets machine state.
With RJG Insight System®, you can.
3
Monitoring Points
➢ Cavity Pressure ➢ Injection Pressure ➢ Stroke Position/Velocity ➢ Temperature
4
Insight System® Layout
eDART™ Workshop with Graph Interpretation
Rev. 4.0 1
RJG Insight System®
➢ eDART™ ➢ Machine sensors ➢ Mold sensors
2
Benefits
➢ Part Containment – Quality assurance in the process
➢ Cavity Pressure Control – Consistency in the Process
➢ Real Time DataInstantaneous viewing of the process
➢ Historical DataAbility to review process
Can you tell which are the good parts?
IA1-D-VI OA1-D-V OR2-D
0-10V or 4-20mA isolated analog input module for signals from machine.
0-10V isolated analog output, feeds signals to machine controller for transfer.
➢ Signals must be 24VDC
10
Sequence Module
ID7-D-SEQ (24VD来自百度文库)
Terminal - Importance Comes On
Goes Off
1. INJ Forward
Injection Starts End of hold
Purpose Search for peaks, hold pressure. (Required for control)
2. 1st Stage
Inj. Starts
Inj. goes to hold Creates internal Inj. Forward, Pack, & in 2-Stage “Fill”
3. Screw Run 4. Mold Clamped
5. Mold Opening 6. Manual
Screw motor Starts
Mold clamped to pressure
Mold opening
Stops Mold cracks Mold fully open
Stroke direction, Zero, Material variation information (Required for control)
Dual relay output, Contact rating – 2A at 24V for control, valve gate application, sorting, or lights.
9
Sequence Module
ID7-D-SEQ
➢ Machine signals connect to terminal 1 through 7, Common to 8
Accurate cycle time, integration limit, Reset Piezo Adapter & UMPI
Pinched part detection, Resets Piezo Adapter & UMPI
Machine in manual
In Full/Semi
Prevents parts counts and data storage while in this
Automatic mode mode
7. Shuttle Position
Start of cycle Position 2
Start of cycle Position 1
Detects mold position in 2-position shuttle molding
8. Input Common
5
eDART™ Components
Essentially a Computer ➢ Data Storage/Memory ➢ Keyboard/Mouse ports ➢ Video output ➢ Ethernet / Modem ➢ Insight Software
6
eDART™ Connections
➢ Power: 24VDC Power Adapter (G) ➢ Lynx Ports: Sensors and Machine Interface Modules (B) ➢ Serial (COM) Port: Remote Access, Touch Screens (A) ➢ Video Connection (C) ➢ Ethernet (NIC): Network (F) ➢ Mouse and Keyboard PS2 Ports ( D&E)
相关文档