fluke红外测温仪说明书

合集下载

Fluke OS681 无接触红外温度计说明书

Fluke OS681 无接触红外温度计说明书

IntroductionEvery object in the universe radiates energy in the infrared spectrum. Infrared energy falls between visible light and radio waves in the electromagnetic spectrum,which includes ultraviolet, gamma and x-rays.Infrared temperature measurement technology is not new . It has been used successfully in aerospace labora-tories as well as manufacturing, maintenance and qual -ity control processes for more than 30 years.The OS681 SeriesThe OS681 is a hand -held, battery-operated sensor that safely and accurately measures temperature using a non contact infrared technology. Operation of the OS681 is simple.Just point the sensor at the desired target and press the "on" button for a temperature reading no contact is everneeded. The OS681 has the first temperature response time of 1 second and a continuous reading feature,which is achieved by holding down the "on" button. The temperature reading is held on the display for 60 sec-onds after the release of the "on" button.The Infrared Syste mInfrared sensors consist of optics, detector, display and output. The OS681 uses special optics to gather infrared energy from a target surface and focuses this energy onto a custom detector. The detector then con-verts the infrared energy into an electrical signal pro-portionate to the temperature of the target surface being measured. The output is a digital temperature measurement in degrees Fahrenheit or Centigrade within milliseconds.Calculating DistanceThe OS681 has a distance-to-target ratio (D/T) of 3:1and measures the emitted energy of a target one-third the size of the working distance.For example, if the distance is 3 inches, the diameter of the measured area is 1 inch.PrecautionsTo ensure accurate temperature readings, it is impor-tant to prevent contact or near contact of the sensin g lens to extreme hot or cold sources. Exposure of more than a few seconds may cause the signal to drift sever-al degrees.EmissivityEmissivity is a characteristic of a target surface and is the relative ability of that surface to emit energy.The OS681 is preset to an emittance value of 0.95-th evalue of most Organic substances. This includes such things as wood, cloth, plastics and water. Highly reflec-tive materials with smooth polished surfaces have emit -tance values much lower than 1.0. To compensate for emissivity when measuring such materials, we recom-mend using flat black paint or attaching black tape to the target to soften the reflectiveness.Laser Sight OptionThe laser is located on the front of the sensor next to the optics and is activated by pressing the "on" button. The laser will produce a red spot from sighting the measured target.CE CertificationThis instrument conforms to the following standards:EN50081-1:1992, Electromagnetic Emissions EN50082-1:1992, Electromagnetic SusceptibilityPerformance of the unit may degrade while in the pres-ence of these electromagnetic fields.CAUTION LABELCaution and apeture label located on the backside of the unit.011-0011 REV B 3/07Battery InstallationThe OS681 requires a standard 9-volt battery.The sensor only requires power during operation; there-fore, the battery should last several months with aver -Lens CleaningDebris on the lens may cause obstruction and reduce the accuracy of the OS681. If this occurs, either wipe the lens with a Q-tip (moistened with water only) or blow off the loose particleswith clean compressed air.Specifications for OS681 Series:Temperature 0 to 600°F (-18° to 315°C) or Range:-67 to 260°F (-55° to 125°C)Resolution:1°F (1°C)Accuracy:± 2% of reading or 3°F (2°C),± 1 digit, whichever is greater Response Time:1 secondTarget Size/3:1 optics ratio with a 1"Field of View :minimum targetRepeatability:± 0.5% of reading, plus one digit Power Source:9-volt battery included Wavelength:8 to 14 micronOperating Temperature:50° to 125°F (10° to 52°C)Dimensions:7.26" x 1.7" x 0.75"Weight: 2.7 oz., 75 grams (w/o battery)Emissivity:Fixed at 0.95Low Battery IndicationA decimal point to the right of the center digit indicates low battery power.Subzero MeasurementsA decimal point to the left of the center digit indicates a subzero temperature reading.Where Do I Find Everything I Need for Process Measurement and Control?OMEGA…Of Course!Shop online at SMPanels & Assemblies TEMPERATUREThermocouple, RTD & Thermistor Probes, Connectors,Wire: Thermocouple, RTD & Thermistor Calibrators & Ice Point References Recorders, Controllers & Process Monitors Infrared PyrometersPRESSURE, STRAIN AND FORCETransducers & Strain GagesLoad Cells & Pressure Gages Displacement TransducersInstrumentation & AccessoriesFLOW/LEVELRotameters, Gas Mass Flowmeters & Flow ComputersAir Velocity IndicatorsTurbine/Paddlewheel SystemsTotalizers & Batch ControllerspH/CONDUCTIVITYpH Electrodes, Testers & AccessoriesBenchtop/Laboratory MetersControllers, Calibrators, Simulators & PumpsIndustrial pH & Conductivity EquipmentDATA ACQUISITIONData Acquisition & Engineering SoftwareCommunications-Based Acquisition Systems Plug-in Cards for Apple, IBM & Compatibles Datalogging SystemsRecorders, Printers & PlottersHEATERSHeating CableCartridge & Strip Heaters Immersion & Band Heaters Flexible HeatersLaboratory HeatersENVIRONMENTALMONITORING AND CONTROLMetering & Control InstrumentationRefractometers Pumps & TubingAir, Soil & Water MonitorsIndustrial Water & Wastewater TreatmentpH, Conductivity & Dissolved Oxygen InstrumentsM2550/0608tion; misapplication; misuse or other operating conditions outside of OMEGA’s control. Components in which wear is not warranted, include but are not limited to contact points, fuses, and triacs.OMEGA is pleased to offer suggestions on the use of its various products.However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by the compamy will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER,EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED.LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with respect to this order,whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages.CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans.Should any Product(s) be used in or with any nuclear installation or activity,medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY / DISCLAIMER language,and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.RETURN REQUESTS /INQUIRIESDirect all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA,PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence.The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit. FOR WARRANTY RETURNS, please have the following informationavailable BEFORE contacting OMEGA:1. Purchase Order number under which the product was PURCHASED,2. Model and serial number of the product under warranty, and3. Repair instructions and/or specific problems relative to the product.FOR NON-WARRANTY REPAIRS,consult OMEGA for current repaircharges. Have the following information available BEFORE contacting OMEGA:1. Purchase Order number to cover the COST of the repair,2. Model and serial number of the product, and3. Repair instructions and/or specific problems relative to the product.OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technologyand engineering.OMEGA is a registered trademark of OMEGA ENGINEERING, INC.© Copyright 2008 OMEGA ENGINEERING, INC. All rights reserved. This docu-ment may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.WARRANTY/DISCLAIMEROMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product.If the unit malfunctions, it must be returned to the factory for evaluation.OMEGA’s Customer Service Department will issue an Authorized Return (AR)number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specifica-U.S.A.:One Omega Drive, Box 4047ISO 9001 CertifiedStamford, CT 06907-0047Tel: (203) 359-1660FAX: (203) 359-7700e-mail:**************Canada:976 BergarLaval (Quebec) H7L 5A1, Canada Tel: (514) 856-6928FAX: (514) 856-6886e-mail:*************For immediate technical or application assistance:U.S.A. and Canada:Sales Service: 1-800-826-6342/1-800-TC-OMEGA Customer Service: 1-800-622-2378/1-800-622-BEST Engineering Service: 1-800-872-9436/1-800-USA-WHEN Mexico:En Espan ˜ol: (001) 203-359-7803e-mail:*****************FAX: (001) 203-359-7807**************.mxServicing Europe:Czech Republic:Frystatska 184, 733 01 Karvina ´, Czech Republic Tel: +420 (0)59 6311899FAX: +420 (0)59 6311114Toll Free: 0800-1-66342e-mail:*****************Germany/Austria:Daimlerstrasse 26, D-75392 Deckenpfronn, GermanyTel: +49 (0)7056 9398-0FAX: +49 (0)7056 9398-29TollFreeinGermany************e-mail:*************United Kingdom:One Omega Drive, River Bend Technology CentreISO 9002 CertifiedNorthbank, Irlam, Manchester M44 5BD United Kingdom Tel: +44 (0)161 777 6611FAX: +44 (0)161 777 6622Toll Free in United Kingdom: 0800-488-488e-mail:**************.ukIt is the policy of OMEGA Engineering, Inc. to comply with all worldwide safety and EMC/EMIregulations that apply. OMEGA is constantly pursuing certification of its products to the European NewApproach Directives. OMEGA will add the CE mark to every appropriate device upon certification.The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves the right to alter specifications without notice.WARNING: These products are not designed for use in, and should not be used for, human applications.e-mail:**************For latest product manuals:User’s GuideOS681Pocket IR PyrometerShop online at。

fluke使用说明书

fluke使用说明书

福禄克FLUKE DTX系列(Dtx-1800,Dtx-1200,Dtx-lt)简单操作步骤说明:一、福禄克测试仪初始化步骤:1、充电:产品主机、辅机分别用电源适配器充电,直至电池显示灯转为绿色;2、设置语言:操作:将fluke dtx系列产品主机旋钮转至“SET UP”档位,按右下角绿色按钮开机;使用↓箭头;选中第三条“Instrument setting ”(本机设置)按“ENTER”进入参数设置,首先使用→箭头,按一下;进入第二个页面,↓箭头选择最后一项Language按“ENTER”进入; ↓箭头选择最后一项 Chinese 按“ENTER”选择。

将语言选择成中文后才进行以下操作。

3、自校准:取fluke dtx系列产品Cat 6A/Class EA 永久链路适配器,装在主机上,辅机装上Cat6A/Class EA 通道适配器。

然后将永久链路适配器末端插在Cat 6A/Class EA 通道适配器上;打开辅机电源,辅机自检后,“PASS”灯亮后熄灭,显示辅机正常。

“SPECIAL FUNCTIONS”档位,打开主机电源,显示主机、辅机软件、硬件和测试标准的版本(辅机信息只有当辅机开机并和主机连接时才显示),自测后显示操作界面,选择第一项“设置基准”后(如选错用“EXIT”退出重复),按“ENTER”键和“TEST”键开始自校准,显示“设置基准已完成”说明自校准成功完成。

二、设置福禄克测试仪基本参数操作:将fluke dtx系列产品主机旋钮转至“SET UP”档位,使用“↑↓”来选择第三条“仪器值设置”,按“ENTER”进入参数设置,可以按“←→”翻页,用“↑↓”选择你所需设置的参数,按ENTER进入参数修改,用“↑↓”选择你所需采用的参数设置,选好后按ENTER 选定并完成参数设置。

1、新机第一次使用需要设置的参数,以后不需更改。

(将旋钮转至“SET UP”档位,使用↓箭头;选中第三条:仪器设置值按ENTER进入如果返回上一级请按EXIT):1) 线缆标识码来源:(一般使用自动递增,会使电缆标识的最后一个字符在每一次保存测试时递增一般不用更改)2) 图形数据存储:(是)(否)通常情况下选择(是)3) 当前文件夹: DEFAULT 可以按ENTER进入修改其名称(你想要的名字)4) 结果存放位置:(使用默认值“内部存储器”假如有内存卡的话也可以选择“内存卡”)5) 按→进入第2个设置页面,操作员:You Name 按ENTER 进入按F3删除原来的字符“←→↑↓”来选择你要的字符选好后按ENTER确定6) 地点: Client Name,是你所测试的地点可以依照地e)小点进行修改7) 公司:You Company Name,你公司的名字8) 语言:Language,默认是英文9) 日期:输入现在日期10) 时间:输入现在时间11) 长度单位:通常情况下选择米(m)2、新机不需设置采用原机器默认值的参数:1) 电源关闭超时:默认30分钟2) 背光超时:默认1分钟3) 可听音:默认是4) 电源线频率:默认50Hz5) 数字格式:默认是6) 将旋钮转至“SET UP”档位选择双绞线按ENTER 进入后 NVP 不用修改7) 光纤里面的设置,在测试双绞线是不须修改3、使用过程中经常需要改动的参数:将旋钮转至“SET UP”档位,选择双绞线,按ENTER进入:线缆类型:按ENTER进入后按↑↓选择你要测试的线缆类型例如我要测试超5类的双绞线在按ENTER进入后选择UTP 按ENTER ↑↓选择“Cat 5e UTP ” 按ENTER 返回。

福禄克红外热像仪使用说明书

福禄克红外热像仪使用说明书

全优方案 全力以赴从精密到简便,从主管到基层,皆有所选!福禄克红外热像仪什么是红外热像仪?红外热像仪的优势典型应用被动接收被测目标发出的红外辐射(热量),并将这种热量转化为带有温度数据的可视化图像(所有高于绝对零度(的物体都会发出红外辐射)。

可见光图红外热图安全快速无遗漏非接触式检测,适应各种工作环境。

面测量无需逐点扫描,毫秒级反应速度,提高工作效率。

可视化图像显示整体温度分布,实时发现问题点。

工业、机械、过程设备、耐节能审核、建电气设备、负修复、水渍以建筑问题、缺坚固耐用易于操作●独有的IR-Fusion®红外-可见光点对点融合技术,完美展示画面细节。

●AutoBlend™优组合模式,实现0%-100%红外融合度轻松调节。

●集成了领先的热灵敏度和空间分辨率,呈现业内最清晰的图像。

●设计可承受2米跌落●IP54防护等级全红外画中画红外/可见报警全可见.5 m1 m1.5 m 5 ft3.25 ft1.6 ft2 m 6.5 ft1. 对准2. 聚焦3. 拍摄对包装产品:8个角、6个面、 12个边跌落试验以10升/分钟、100 kN/m2压力进行防水试验3个垂直轴方向进行30分钟的振动试验湿度95% @ 40℃工作环境下测试电磁场和射频辐射试验模拟海拔12,000米工作环境下测试对未包装产品:2米跌落试验,每一面进行6次-10℃至50℃工作环境下测试12345678冠名福禄克之前,需经过8项耐损试验Ti400Ti300Ti200 1.31mRad 1.75mRad 2.09mRadTi25Ti10Ti92.5mRad 2.5mRad 2.5mRadTi29Ti27Ti125Ti110Ti105Ti100 1.43mRad 1.67mRad 3.39mRad 3.39mRad 3.39mRad 3.39mRadTi95Ti90VT02 5.6mRad 5.6mRad对焦不准确的热图传统自动对焦:聚焦于最近的物体,即画面中的铁丝网。

fluke中文使用手册805彩图

fluke中文使用手册805彩图
enter保存设置插孔盖状态指示灯照明灯开关背光灯开关测振传感器红外测温传感器照明灯usb插孔外部传感器插孔音频插孔测量提示指示灯状态先按然后再将测振仪对准测试表面
快速参考指南
测量提示
指示灯状态 符合 ISO 10816-1 的振动烈度
机器 in/s
90˚
0.01 0.02 0.03 0.04
数据传输
LCD 显示屏
红外测温 传感器
绿灯亮 绿灯灭 将传感器尖端放到测试表面 上,尽量靠近轴承。 施加压 力,直到绿灯熄灭。
绿灯灭 数据测量完成。
红灯亮 出错。用力或持续 时间不足,无测量 数据。
1.10 1.77
测振仪运用一种专属的算法:Crest Factor + (CF+)。 为了方便用户理解,CF+ 的 烈度等级在 1 到 16 之间取值。 CF+ 值越高,说明轴承受损程度越大。 每次测量获得的 CF+ 值显示在测振仪显示屏的轴承字段。 按 和 可在 CF+ 值和 以加速度为单位的高频振动级别之间切换。
使用前必读
导航
一般性操作: 面底部提供了关于
在菜单选项间移动光 标或编辑菜单选项 调用上一个菜单 打开下一个菜单或设 定选项 为测振仪保存新的选 项设置
测振仪配置
“设置”菜单
测量
快速测量 自动保存测量值
每个菜单都在界 其内容的导航提示。
单位
为防止红外测温仪导致人身伤害: ●● 有关实际温度,请参阅发射率信息。 反光物体会导致测得的温度比实际温度要低。 这些物体会 产生烧伤危险。 ●● 请勿在高温且无人照看的情形下使用产品。 为防止靠近转动设备而导致人身伤害: ●● 在转动设备周围要小心。 ●● 让绳索和带子隐藏起来。

fluke红外测温仪说明书

fluke红外测温仪说明书
可能已遭破坏。若有疑问,应把测温仪送去维修。 • 切勿在有爆炸性的气体、蒸汽或灰尘附近使用测温
仪。 • 请勿将选用的外接探头与通电的电路连接。 • 为避免灼伤,请记住反射率高的物体上所测得的温
度要低于实际温度。 • 若未按照本手册规定的方式使用测温仪,设备提供
的保护功能可能会失效。 W小心
为避免损坏测温仪或被测设备,请保护它们免受以下影 响: • 弧焊机和感应加热器等产生的 EMF(电磁磁场)。 • 静电 • 热冲击(由于环境温度发生较大或突然改变引起,
P
符合欧盟和欧洲自由贸易联盟(EFTA)要求。
°C
摄氏度
°F
华氏度
M
~
电池
请勿将本品作为未分类的城市废弃物处理。请访 问 Fluke 网站了解回收信息。
3
63/66/68 Infrared Thermometers
图 1. 测温仪上的安全标志
ame011.eps
4
63/66/68 特点
特点
测温仪包括: • 单点激光瞄准 • MAX(最高)温度显示 • 背光显示 • 结实耐用、符合人体工学的结构 • 三脚架安装 • 硬式携带箱和腕带 • MAX(最高)、MIN(最低)、DIF(差值)、AVG(平 均)温度显示(66/68 型) • 发射率可调(66/68 型) • 高温和低温报警(66/68 型) • 数据记录(66/68 型) • 扳机锁定(66/68 型) • 探头插孔(66/68 型)
有限担保和有限责任
Fluke 公司保证本产品从购买日起两年内,其材料和工艺上 均无瑕疵。本项担保不包括保险丝、一次性电池或者因意 外、疏忽、误用或非正常情况下的使用或处理而损坏的产 品。经销商无权代表 Fluke 公司提供任何额外的担保。欲在 担保期内取得担保服务,请与您最近的 Fluke 授权服务中心 联系,以获取有关产品退还的授权信息,然后将产品及故障 说明寄至该服务中心。

Fluke 59 MAX 59 MAX+ 红外射线测温仪说明书

Fluke 59 MAX 59 MAX+ 红外射线测温仪说明书

Technical DataProduct highlights• Precise laser technology for more accurate and repeatable measurements• Large, easy-to-read backlit LCD display for easy viewing • Small and lightweight design fits easily fits into your tool box • IP40 rated for extra protection • 10:1 Distance to Spot ratio, 59 MAX+ (8:1 Distance to Spot ratio, 59 MAX)• Displays the minimum, maxi-mum or average temperature, or the difference between two measurements• Hi and Lo alarms for rapid display of measurements outside the limits• Powered by one (1) AA battery• One year warrantyFluke 59 MAX/59 MAX+ Infrared ThermometerFits your budget. Fits your job.Specifications2 Fluke Corporation Fluke 59 MAX/59 MAX+ Infrared Thermometer3 Fluke Corporation Fluke 59 MAX/59 MAX+ Infrared ThermometerOrdering informationFluke 59 MAX Infrared Thermometer Fluke 59 MAX+ Infrared Thermometer Included:Thermometer, One (1) AA battery, registration card and user instructions.Fluke CorporationPO Box 9090, Everett, WA 98206 U.S.A.Fluke Europe B.V.PO Box 1186, 5602 BD Eindhoven, The NetherlandsFor more information call:In the U.S.A. (800) 443-5853 or Fax (425) 446-5116In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222In Canada (800)-36-FLUKE or Fax (905) 890-6866From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116Web access: ©2013 Fluke Corporation.Specifications subject to change without notice. Printed in U.S.A. 6/2013 6000025A_ENModification of this document is not permitted without written permission from Fluke Corporation.Fluke. The Most Trusted Toolsin the World.Technical Dataof the intended target. The measured area increases with distance(the distance divided by 12, approximately).Fluke 561 HVACProTwo-in-one infrared and contactthermometer for HVAC/R ProfessionalsFeatures include:• IR thermometer for quick mea-surements up close or at a distance, without a ladder• Contact thermometry capability, compatible with all standard mini-connector K-type ther-mocouples, preserves your investment in thermocouples • Velcro ® pipe probe for super-heat and sub-cooling and other contact and ambient measurements• Single-point laser sighting • Temperature range optimized for HVAC/R applications • Easy emissivity adjustment for measuring pipes and ducts more accurately• Lightweight (just 12 ounces/ 340 grams) and portableThe multipurpose thermometer you need for HVAC jobs.Lighten up your toolbox. The Fluke 561 HVACProcombines the temperature measurement functions that professionals need for most HVAC jobs, all in one tool. It measures both IR and contact temperature , replacing several hundred dollars worth of equipment. It’s fast, effi-cient and easy to use, saving you valuable time and effort.With the Fluke 561, you can take contact and ambient temperatures in the way that’s best for you. Use the IR thermometer to measure hot, moving, electrically ener-gized and hard-to-reach objects instantly. Check motors, insulation, breakers, radiant heating, pipes, corroded con-nections and wires. Plus, scan ducts from the floor—leave your ladder in the truck. You can use the Fluke 561’shandy Velcro ® pipe probe or, to get the most out of your tool investments, plug in any industry-standard K-type mini-connector thermocouple probes you already own.• Very easy to use• Efficient—no need to shut downequipment when making IR measurements• MIN, MAX and DIF functions help you quickly identify problems• Scan large areas or small objects quickly and efficiently • HVAC/R measurement guide to maximize your productivity Laser-guided sighting for IR measurementsWhen using the Fluke 561 in sighting system guides measure-indicates the approximate center of the measurement area.Fluke CorporationPO Box 9090, Everett, WA USA 98206Fluke Europe B.V.PO Box 1186, 5602 BD Eindhoven, The NetherlandsFor more information call:In the U.S.A. (800) 443-5853 or Fax (425) 446-5116In Europe/M-East/Africa (31 40) 2 675 200 or Fax (31 40) 2 675 222In Canada (800) 36-FLUKE or Fax (905) 890-6866From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116Web access: ©2006 Fluke Corporation. All rights reserved. Velcro is a registered trademark of Velcro Industries B. V. Printed in U.S.A. 2/2006 2630651 D-EN-N Rev AFluke. Keeping your world up and running.Ordering informationFluke-561 HVACProIncludes: Infrared thermometer with contact thermometer capabilities, thermocouple K-type Velcro ® pipe probe, hand carrying case and user manual with HVAC measurement guide.Technical DataFluke 566 and 568Thermometers• Measure -40 °C to 800 °C /-40 °F to 1472 °F (568)or -40 °C to 650 °C/-40 °F to 1202 °F (566)• Easily access advanced features with the soft-key buttons and graphical display• Measure smaller objects from further away, with a distance-to-spot ratio of 50:1 (568) or 30:1 (566)• Compatibility with all standard miniconnector K-type thermocouples allows you to preserve your thermocouple investments• Confidently measure a wide variety of surfaces with the adjustable emissivity feature, including a built-in material table• Capture up to 99 points (568) or 20 point (566) of data, for downloading and recalling later • Easily trend and analyze data with included FlukeView ® Forms software (568)• See your data right away without leaving thesite, using the USB (568) and your laptop for “Hands-free” datalogging• Confidently troubleshoot equipment with 1 % measurement accuracy• Versatile interface with six languages from which to choose• Two-year warrantyJust when you thought advanced IR tem-perature measurement should be easier! With a straight-forward user interface and soft-key menus, the Fluke 566 and 568 make even complex measurements easy. Quickly navigate and adjust emissivity, start data logging, or turn on and off alarms, with just a few pushes of a button.With a rugged, easy-to-use, ergonomic design, the Fluke 566 and 568 can stand up to tough industrial, electrical, and mechanical environments.Fluke-566 Infrared thermometerFluke-568 Infrared thermometerIncludes: Infrared thermometer with con-tact thermometer capabilities, FlukeView ® Forms software (568 only), USB cable (568 only), K-type thermocouple bead probe, hard carrying case, quick start guide, and users manual.Fluke CorporationPO Box 9090, Everett, WA 98206 U.S.A.Fluke Europe B.V.PO Box 1186, 5602 BD Eindhoven, The NetherlandsFor more information call:In the U.S.A. (800) 443-5853 or Fax (425) 446-5116In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222In Canada (800)-36-FLUKE orFax (905) 890-6866From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116Web access: ©2007 Fluke Corporation. All rights reserved. Specifications subject to change without notice. Printed in U.S.A. 8/2007 3085001 D-EN-N Rev AFluke. Keeping your world up and running.®。

福禄克Ti200红外热像仪使用说明书

福禄克Ti200红外热像仪使用说明书

Ti200, Ti300, Ti400Thermal Imagers用户手册September 2013, Rev.1, 5/15 (Simplified Chinese)© 2013-2015 Fluke Corporation. All rights reserved.Specifications are subject to change without notice.All product names are trademarks of their respective companies.有限保证和责任限制在正常使用和维护条件下,Fluke公司保证每一个产品都没有材料缺陷和制造工艺问题。

保证期为从产品发货之日起二(2)年。

部件、产品修理和服务的保证期限为90天。

本项保证仅向授权零售商的原始买方或最终用户提供,并且不适用于保险丝和一次性电池或者任何被Fluke公司认定由于误用、改变、疏忽、意外非正常操作和使用所造成的产品损坏。

Fluke公司保证软件能够在完全符合性能指标的条件下至少操作90天,而且软件是正确地记录在无缺陷的媒体上。

Fluke公司并不保证软件没有错误或无操作中断。

Fluke公司仅授权零售商为最终客户提供新产品或未使用过产品的保证。

但并未授权他们代表Fluke公司提供范围更广或内容不同的保证。

只有通过Fluke授权的销售商购买的产品,或者买方已经按适当的国际价格付款的产品,才能享受Fluke的保证支持。

在一个国家购买的产品被送往另一个国家维修时,Fluke 公司保留向买方收取修理/更换零部件的进口费用的权利。

Fluke公司的保证责任是有限的,Fluke公司可以选择是否将依购买价退款、免费维修或更换在保证期内退回到Fluke公司委托服务中心的有缺陷产品。

要求保修服务时,请与就近的Fluke授权服务中心联系,获得退还授权信息;然后将产品连同问题描述寄至该服务中心,并预付邮资和保险费用(目的地离岸价格)。

FLUKE说明书

FLUKE说明书

ENTER !"#$%& !"# !" 744
4
Auto Test ! !"#
!"#$%&#'()
!"#$%&' Send 4mA 20mA
!"#$%& Fetch
P !"# ì å á î É ê ë ~ ä Åçãã~åÇ e^oq
744 744 !"#$ sensor trim !"#$%&'() HART !"#$ 1 !"# !"#$%&'()*+',-. devide-specific command !"# 744 !"#$%&?
!"#$%&'$%( !"#$%#&'HART !"#$%&'() !"#$% smart !"# !"# 1 !"#$%&'()* !
Southwest Research Institute !"# Intech
!"#$%&'(
"#$%&'()*+, !" !"# !"#$%
!"#$%&'()*+ ,)!"#$%&'()*+,-( !"#$%&'()*+"# !"#$%&'() !"#$%&'()*+, !" # 2 !"#$% !"#$ !"#$ !" 3 !"

Fluke 62 MAX 62 MAX+ 红外温度计用户手册说明书

Fluke 62 MAX 62 MAX+ 红外温度计用户手册说明书

PN 4060712April 2012 Rev. 1, 11/12© 2012 Fluke Corporation. All rights reserved. Printed in China. Specifications are subject to change without notice.All product names are trademarks of their respective companies.62 MAX/62 MAX +Infrared ThermometerLIMITED WARRANTY AND LIMITATION OF LIABILITYThis Fluke product will be free from defects in material and workmanship for three years from the date of purchase. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warranty on Fluke’s behalf. To obtain service during the warranty period, contact your nearest Fluke authorized service center to obtain return authorization information, then send the product to that Service Center with a description of the problem.THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE IS NOT LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this limitation of liability may not apply to you.Fluke CorporationP.O. Box 9090 Everett, WA 98206-9090 U.S.A. Fluke Europe B.V. P.O. Box 1186 5602 BD Eindhoven The Netherlands11/99Table of ContentsTitle Page Introduction (1)How to Contact Fluke (1)Safety Information (2)Maintenance (6)How to Change the Battery (6)How to Clean the Product (6)Specifications (7)Standards and Agency Approval (9)The Product (10)iIntroductionThe Fluke 62 MAX and 62 MAX + Infrared Thermometers (the Product) can determine the surface temperature by measuring the amount of infrared energy radiated by the target’s surface. Note that the Japanese models indicate Celsius only.WarningRead all safety information before you use the Product.162 MAX/62 MAX +Users ManualSafety InformationA Warning identifies conditions and procedures that are dangerous to the user. A Caution identifies conditions and procedures that can cause damage to the Product or the equipment under test.Table 1 tells you about symbols used on the Product and in this manual.WarningTo prevent eye damage and personal injury:•Read all safety Information before you use the Product.•Do not use the Product if it operates incorrectly.•Use the Product only as specified, or the protection supplied by the Product can be compromised.•Before you use the Product, inspect the case. Do not use the Product if it appears damaged. Look for cracks or missing plastic.2Infrared Thermometer Safety Information3•See emissivity information for actual temperatures. Reflective objectsresult in lower than actual temperature measurements. These objects pose a burn hazard.•Do not look directly into the laser with optical tools (for example,binoculars, telescopes, microscopes). Optical tools can focus the laser and be dangerous to the eye.• Do not look into the laser. Do not point laser directly at persons or animals or indirectly off reflective surfaces.• Replace the batteries when the low battery indicator shows to prevent incorrect measurements.• Do not use the Product around explosive gas, vapor, or in damp or wet environments.•Use the Product only as specified or hazardous laser radiation exposure can occur.62 MAX/62 MAX + Users Manual4Table 1. SymbolsSymbol MeaningSymbol MeaningRisk of danger. Importantinformation. See Manual.This product complies with theWEEE Directive (2002/96/EC)marking requirements. Theaffixed label indicates that youmust not discard thiselectrical/electronic product indomestic household waste.Product Category: Withreference to the equipment typesin the WEEE Directive Annex I,this product is classed ascategory 9 "Monitoring andControl Instrumentation” product.Do not dispose of this product asunsorted municipal waste. Go toFluke’s website for recyclinginformation.Infrared Thermometer Safety Information5Table 1. Symbols (cont.)Symbol Meaning SymbolMeaningWarning. Laser. Conforms to European Uniondirectives.BatteryConforms to relevant Australian standards.Conforms to China Metrology Certification62 MAX/62 MAX +Users ManualMaintenanceCautionTo avoid damage to the Product, do not leave the thermometer on or nearobjects of high temperature.How to Change the BatteryTo install or change the AA IEC LR06 battery, open the battery compartment and replace the battery as shown in Figure 16.How to Clean the ProductUse soap and water on a damp sponge or soft cloth to clean the Product case. Carefully wipe the surface with a moist cotton swab. The swab may be moistened with water. See Figure 17. 6Infrared ThermometerSpecifications7Specifications62 MAX62 MAX +Temperature Range-30 °C to 500 °C (-22 °F to 932 °F)-30 °C to 650 °C (-22 °F to 1202 °F) Accuracy(Calibration geometry with ambient temperature 23 °C ±2 °C)≥0 °C: ±1.5 °C or ±1.5 % of reading, whichever is greater(≥32 °F: ±3 °F or ±1.5 % of reading, whichever is greater)≥ -10 °C to <0 °C: ±2 °C (≥14 °F to <32 °F: ±4 °F) < -10 °C: ±3 °C (<14 °F: ±6 °F)≥0 °C: ±1 °C or ±1 % of reading, whichever is greater (≥32 °F: ±2 °F or ±1 % of reading, whichever is greater)≥ -10 °C to <0 °C: ±2 °C (≥14 °F to <32 °F: ±4 °F) < -10 °C: ±3 °C (<14 °F: ±6 °F)Response Time (95 %) <500 ms (95 % of reading) <300 ms (95 % of reading)Spectral Response 8 to 14 microns Emissivity0.10 to 1.00Temperature Coefficient ±0.1 °C/°C or ±0.1 %/°C of reading (whichever is greater)62 MAX/62 MAX + Users Manual8 Optical Resolution10:1(calculated at 90 % energy)12:1(calculated at 90 % energy) Display Resolution 0.1 °C (0.2 °F)Repeatability (% of reading)±0.8 % of reading or ±1.0 °C(2 °F), whichever is greater±0.5 % of reading or ±0.5 °C(1 °F), whichever is greater Power 1 AA IEC LR06 BatteryBattery Life10 hours with laser andbacklight on8 hours with laser andbacklight onWeight 255 g (8.99 oz)Size (175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inchesOperating Temperature 0 °C to 50 °C (32 °F to 122 °F)Storage Temperature -20 °C to 60 °C (-4 °F to 140 °F), (without battery) Operating Humidity 10 % to 90 % RH non-condensing @ 30 °C (86 °F) Operating Altitude 2000 meters above mean sea levelStorage Altitude 12,000 meters above mean sea levelInfrared Thermometer Standards and Agency Approval9Ingress Protection Rating IP 54 per IEC 60529 Drop Test3 metersVibration and Shock IEC 60068-2-6 2.5 g, 10 to 200 Hz, IEC 60068-2-27, 50 g, 11 msEMCEN 61326-1:2006 EN 61326-2:2006Standards and Agency ApprovalCompliance ............................................. E N/IEC 61010-1 Laser Safety ............................................ E N 60825-1 Class 2 Implement Standard ............................... Q /SXAV3762 MAX/62 MAX + Users Manual10InfraredThermometerProduct The Array1162 MAX/62 MAX + Users Manual12InfraredThermometerProduct The Array1362 MAX/62 MAX + Users ManualInfraredThermometerProduct The Array1562 MAX/62 MAX + Users Manual16InfraredThermometerProduct The Array17。

fluke说明书[1]

fluke说明书[1]

福禄克F430系列三相电能质量分析仪更快、更安全、更详细地定位和诊断的电能质量故障技术参数福禄克公司的F434 和F433三相电能质量分析仪可以帮助用户定位、预测、防止和诊断配电系统的故障。

对于那些维护或排障三相配电系统的工作人员来说,这些简便易用的手持工具是“必不可少”的。

新的IEC和GB国标关于闪变和电能质量方面的标准使得在对系统进行电能质量分析监测时有了判断的依据。

●记录三相系统中所有电能质量的参数。

●直观的菜单,最大程度上减少所需的设置。

●工业现场使用最高的安全等级。

●四个电压通道和四个电流通道。

●同时在所有相线上捕获波形数据。

●系统监测:在一个仪表板上现实全部电能质量参数。

●自动显示瞬态尖峰脉冲信号:不会漏掉任何一个事件。

●自动趋势绘图(AutoTrend)功能:无需对记录进行设置!●坚固的手持式设计。

●使用镍氢(NiMH)电池组时,一次充电可使用7个小时。

●将数据文件传输到PC,用于编写报告和利用FlukeView®软件进行分析。

CAT IV 600 V 和CAT III 1000 V的安全等级在设计时就考虑了保护用户和设备免受高压电击,福禄克F430系列电能质量分析仪、附件和充电器都经过验证,满足CAT IV 600 V和CAT III 1000 V环境下使用的严格的安全标准。

它们是同类别中第一款符合CAT IV安全等级的工具,所以可以被用于低压配电系统中所有的电气连接和插座。

快捷地观察趋势图利用AutoTrend(自动趋势绘图)功能,可以快速地深入浏览电能质量参数随时间的变化。

所显示的每一读数都被自动并且连续的进行记录,而不必设置触发限值或间隔时间,也无需手动启动记录过程。

可以快速地观察所有相线和零线上电压、电流、频率、功率、谐波或闪变的趋势图;还可以使用光标和缩放功能分析趋势-而不会中断记录。

AutoTrend功能在后台自动记录显示的所有参数。

在数据和趋势图之间切换,以及使用光标和缩放功能分析测量结果,都不会中断记录过程。

红外测温枪说明书fluke572

红外测温枪说明书fluke572

3
D
16
572
DIP设置
17
572
故障诊断
o
18
572
维修
透镜清洁: 用压缩空气吹掉微粒。用 驼绒毛刷 刷掉残留的碎 片。并用湿棉签擦拭 表面塑料。湿棉签应由清 水或清洁 镜片的水润湿。 注意: 请勿用溶剂清洁塑料 透镜。
清洁外壳: 清洁外壳用肥皂和水或中 性清洁剂。用潮湿的海绵 或软布擦拭。
光斑尺寸 光斑尺寸
标准焦距 ��������������
�������������
������������������������������� ��������������
���
���
���������������
���
��� ���� ���� ����
���
����
����
���
���
���
��������������
572
Precision Infrared Thermometer
September 2004 (Simplified Chinese)
© 2004 Fluke Corporation, All rights reserved. Printed in USA. All product names are trademarks of their respective companies.
����������������� �������������
�������������������������������




���
���
����
� ��� ���
���
����

Fluke 570 系列无人机红外温度计说明书

Fluke 570 系列无人机红外温度计说明书

PRODUCTThe Fluke 570 series infrared thermometersMeasure temperature with Ease andPrecisionThe new Fluke 570 series are the most advancedIR thermometers, and are ideal for predictive andpreventative maintenance applications.The series consists of 3 models offering a broadtemperature range an5 3yue dimension laser t fo r p r e c i s e ta r g e t i n g r e s u l t i n g i n• Enhanced optics allows measurements ofsmaller objects from farther away• Coaxial three-dot laser sighting systemhighlights the true diameter of measurementspots at all distances• Adjustable emissivity setting and 30 pre-setcommon material values for more accurate measurements• 100 data point memory for storage of measurements (Fluke 574, 576) and photographic images (Fluke 576)• Instantly captures photographs of temperature measurement locations for improved documentation (Fluke 576 only)• Backlit Display, holds 7 seconds• Bar graph of last ten readings• Includes software to log, graph and analyze temperature data ArrayIncluded accessories• Thermocouple K probe (Fluke-574 and Fluke-576)• Power supply (Fluke-574)• Windows-based software on CD in 8 languages(English, Spanish, French, Italian, German,Portuguese,SimplifiedChinese) (Fluke-574 and Fluke576)• USB cable (Fluke-576) or RS232 cable (Fluke-574)• Durable hard case• 2 AA batteries• User’s manual on CD in 8 languages(English, Spanish, French, Italian, German, Portuguese, Japanese and Simplified Chinese) • Printed Quickstart in 8 languages(English, Spanish, French, Italian, German, Portuguese, Japanese and Simplified Chinese) WarrantyThe Fluke 570 series will come with 2 years warrantyOptional accessories:• AN5: Analog data cable• C570: Non-contact thermometer holsterProduct specifications:Temperature range -30 to 900°C Display Resolution 0.1°C of reading up to 900°CD:S (Distance to spot size) 60:1 Standard focus 50:1 Close focusMinimum measurement diameter 19mm Standard focus 6mm Close focusLaser sighting Three point coaxial laserEmissivity Adjustable digitally adjustable from 0.10 to 1.0 by 0.01Display Accuracy (Assumes ambient operating temperature of 23°C to 25°C)±0.75% of reading±1% of reading or ±0.75°C whichever is greaterResponse time 250 mSec (95% of reading) Repeatability ±0.5% of reading or ±1°C whichever is greater Spectral response 8 µm to 14 µmLaser Sighting Laser turns off above ambient temperature of 40°C Relative humidity 10% to 90% RH non-condensing, at <30°C Tripod mount ¼ in. 20 UNC threadingPower 2 AA batteries 2 AA batteries/ ACadapter2 AA batteries/ USBBattery life (alkaline) 13 hours with laserand backlight on50%13 hours with laserand backlight on50%8 hours (13 hours withphotographic mode off) 50 photoswith flash; 200 photos w/o flashDisplay hold 7 secondsLCD backlit YesOperating temperature0°C to 50°CStorage temperature-20°C to 50°CMAX, MIN temperatures YesDIF, AVG temperatures No YesAudible and visible alarms Lo w High and lowBar graph display YesUp to 100 points data logging No Data only Data plus photos Data graphing and storage software(Windows compatible)No Data only Data plus photos Weight 480 gr 580 gr Size 240 mm x 170 mm x 55 mm?。

Fluke全优系列红外热像仪产品说明书

Fluke全优系列红外热像仪产品说明书

坚固、精准、性能卓越。

• 节省时间 – 以无线方式,直接从热像仪将图像同步到 Fluke Connect ® 系统,并附加到资产记录或工作单。

访问各地的检查测量,更快作出决策。

团队成员可在检查点和办公室即时看到相同的数据。

• 从采用 IR-Fusion ® 技术的一幅精确融合图像或画中画图像中获得视觉背景和红外细节。

• 从接近 15 cm (6 in) 距离采用手动对焦获取精确对焦图像,或者选择固定焦距快速获取图像,无需从 45 cm (1.5 ft) 及以外距离对焦。

• 借助带 LED 电量指示的智能电池,可监视您的电池电量,从而避免意外断电。

• 可将图像保存到可移除 SD 卡上以方便随时查看。

• 使用 IR-PhotoNotes™ 或语音附注*,用红外图像数字记录重要信息,如设备或电机铭牌的位置。

B与 Fluke Connect ® 兼容*随机型而异技术参数TiS75、TiS65、TiS60、TiS55、TiS50、 TiS45、TiS40、TiS20 和 TiS10 红外热像仪Fluke 全优系列良好的图像质量 分辨率高达 320 X 240分辨率TiS75320 x 240 D:S 514:1TiS65/60 260 x 195D:S 417:1TiS55/50 220 x 165D:S 353:1TiS45/40160 x 120 D:S 257:1TiS20120 x 90D:S 193:1TiS1080 x 60视场35.7 °H x 26.8 °V在一个采用 IR-Fusion ® 技术的图像中查看问题和位置。

完全的红外50 % 混合,画中画模式50 % 混合*Fluke Connect® SmartView® 分析和报告软件在所有国家/地区均有提供,而 Fluke Connect 并非如此。

有关是否提供,请咨询您的授权 Fluke 经销商。

Fluke OS-651 无接触红外温度计说明书

Fluke OS-651 无接触红外温度计说明书

J-43SpecificationsRange: -29 to 1093°C (-20 to 2000°F)Accuracy:±1% rdg ±1 digit Resolution:1°C/°FMin Spot Size:1" Dia. @ 30"Emissivity:0.10 to 0.99 in 0.01 steps Response Time:1 secSpectral Response:8 to 14 microns Power:9 V alkaline battery (included)Output:0.1 mV/degree Battery Life: 200 hrAmbient Temp:4 to 43°C (40 to 110°F)Size:150 H x 230 W x 60 mm D (6 x 9 x 2.5")Weight: 0.9 kg (2 lb)Rugged IR ThermometersUp to 60:1 OpticsOS651Starts at£535ߜ°C/°F Switchable ߜ-29 to 1093°C(-20 to 2000°F) Range ߜRugged Design ߜ±1% rdg Accuracy ߜAnalogue Output Standard, 0.1 mV per DegreeߜOptional Laser Sighting with Either 30:1 or 60:1 Opticsߜ0.10 to 0.99 Adjustable EmissivityߜPeak Hold FeatureThe OS-651 thermometer is rugged,compact and easy-to-use for non-contact temperature measurements in industrial and maintenance applications. Fast and accurate,Models OS-651 and OS-651-LS (with optional laser sighting) both feature adjustable emissivity from 0.10 to 0.99, making them well suited for surface measurements.Both have standard 0.1 mV per degree output which can be sent to a recorder or datalogging device.The Model OS-651-LS features a laser sight for applications that require precise sighting to ensure accurate measurements.OS651-LS with laser sight, £600.Ordering Example: OS-651-LS,pyrometer with laser sight and OS-651-CASE,carrying case, £535 + 50 = £585. OCW-3, OMEGACARE SM extends standard 2-year warranty to a total of 5 years (£150), £585 + 150 =£735.OMEGACARE SM extended warrantyprogramme is available for models shown on this page. Ask your sales representative for full details when placing an order.OMEGACARE SM covers parts, labour and equivalent loaners.。

Fluke 62 Mini 无接触红外热度测量仪说明书

Fluke 62 Mini 无接触红外热度测量仪说明书

The Fluke 62 Mini Infrared ThermometerNon-contact temperature measurementNon-contactdiagnostic toolThe Fluke 62 Mini infraredthermometer is a non-contactdiagnostic tool for quickbasic temperature checks inapplications where a technician is close to the target object. Simple to use, the Fluke 62 Mini enables technicians to discover temperature discrepancies before they become problems. Professionals can troubleshoot maintenance problems by measuring surface temperatures of motors, electrical equipment, insulated walls and pipes, heating, ventilation and refrigeration systems allfrom a safe distance.Features include:•T emperature measurement range up to 500 ºC (932 ºF)• High-resolution optics•A ccurate to within ± 1%of reading• MAX temperature display • Laser sighting• Backlit displayTechnical Dataapproximate center of the measurement pact and convenient, the Fluke 62 Mini thermometer makes troubleshootingquick and easy and is useful anywhere that temperature plays a role in product quality or equipment maintenance. The single dot laser indicates the center of the target; the large temperature display provides current and MAX surface temperatures.Optical resolutionUse the Fluke 62 Mini within six feet of the intended target. At greater distances, the measured area will be larger (approximately the distance divided by 10). The Fluke offset single-point laser indicates the approximate center of the measurement area.Ordering informationFluke 62 Mini Infrared Thermometer Included:Storage Pouch-30 °C to 500 °C (-20 °F to 932 °F)10 ºC to 30 ºC (50 ºF to 86 ºF): ± 1 ºC (2 ºF)Outside 10 ºC to 30 ºC (50 ºF to 86 ºF): ± 1.5 ºC (3 ºF) or ± 1.5% of reading,whichever is greater±0.5% of reading or < ±1 °C (±2 °F),whichever is greater Preset 0.95< 500 mSec10:1 calculated @ 80% energy 6.5–18 microns thermopile detector 0.2 °C (0.5 °F)••°C or °F selectable0 to 50 °C (32 to 120 °F)10-90% RH non-condensing, @ up to 30 °C (86 °F)Up to 2 m (6 ft)Single offset laser 200 g (7 oz);152 x 101 x 38 mm (6 x 4 x 1.5 in)9 V Alkaline battery (included)12 hours-20 ºC to 65 ºC (-4 ºF to 150 ºF) without battery Includes protective boot and storage holster 2 years (conditional)Measurement range AccuracyRepeatabilityEmissivityResponse timeDistance to spot size Spectral range Display resolutionDisplay hold (7 seconds)LCD backlitTemperature displayAmbient operating range Relative humidity Typical distance to target (spot)Laser class IIWeight/dimensions PowerBattery life (alkaline)Storage temperature Options/accessories:Warranty:SpecificationsFluke. Keeping your worldup and running.Fluke CorporationPO Box 9090, Everett, WA USA 98206Fluke Europe B.V.PO Box 1186, 5602 BDEindhoven, The NetherlandsFor more information call:In the U.S.A. (800) 443-5853 or Fax (425) 446-5116In Europe/M-East/Africa (31 40) 2 675 200 or Fax (31 40) 2 675 222In Canada (800) 36-FLUKE or Fax (905) 890-6866From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116Web access: http://www.fl /©2005 Fluke Corporation. All rights reserved.Printed in U.S.A. 4/2005 2437622 D-US-N Rev A。

Fluke 温度仪说明书

Fluke 温度仪说明书

Temperature Panel and Benchtop Meters1⁄8DIN Size with LCD DisplayModel BS6000ASingleThermocouple Input$495Model BS6050Single RTD Input$495Model BS6051Six-Channel RTD Selectable$595Specifications for DP5000A and BS6000 SeriesInputs:Thermocouples: J, K, T, E, N, R, S; RTD Pt100, 2-, 3-, or 4-wire, Alpha 0.00385,Thermistor: 2252 Ωat 25°C (77°F).Display: 4-digit, backlit LCD Accuracy:±0.15% of rdg + 0.2°C at orabove 0°C (+0.4°F) at or above 32°F)±1°C below 0°C (±2°F below 32°F)Resolution:0.1°to 999.9°; 1°above 1000°Temperature Coefficient:0.01% of rdg/°CCold Junction Compensation: 0.0075°C/°C (0.0135°F/°F)Ambient Temperature : 0 to 50°C (32 to 122°F)Storage Temperature:-40 to 50°C (-40 to 122°F)Humidity: 0 to 70% non-condensing Power : 110 Vac (standard),Optional 230 Vac or 9 to 30 Vac/dcM-101ߜEasy-to-Read Backlit LCD ߜ°C/°F Switchable ߜ0.1°/1°Auto Ranging ߜThermocouple Selectable by Rear Panel SwitchesߜFront Panel Splash-Proof (IP65)ߜCan Be Used with OS36, OS37, and OS38 Infrared Probes ߜOptional RS-232ߜBenchtop Portable Meters ߜRugged ABS Case ߜAvailable as Single- or Six-Input ModelsDimensions:DP5000A, DP5050, DP5060:96 x 48 x 120 mm (3.78 x 1.89 x 4.72")BS6000A, BS6050, BS6060:118 x 57 x 150 mm (4.65 x 2.24 x 5.90")BS6001A,BS6051, BS6061:148 x 67 x 190 mm (5.83 x 2.64 x 7.48")Weight:DP5000A, DP5050, BS5060: 255 kg (0.56 lb)BS6000A, BS6050, BS6060: 500 g (1.1 lb)BS6001A, BS6051, BS6061: 850 g (1.87 lb)The DP5000A and BS6000 series of temperature panel and benchtop meters are both highly versatile and accurate. Available in thermocouple and infrared inputs, thermistor and RTD versions with 0.1 degree resolution, auto ranging to 1 degree above 1000°. The thermocouple versions are switch selectable for one of six thermocouple types from the rear panel. The DP5000A series is micro-processor driven andfully self-calibrating, offering exceptional accuracy and long term stability. The backlit LCD is easy to read in any light conditions from dim to bright sunlight, or fluorescent lighting.To Order (Specify Model Number)Model No.Price DescriptionDP5000A $245T/C input panel meter with infrared sensor input*DP5050245RTD input panel meterDP5060245Thermistor input panel meterBS6000A*495Benchtop meter: 1 T/C and OS36, OS37 OS38 input BS6001A*595Benchtop meter: 6 T/C and OS36, OS37 OS38 inputs BS6050495Benchtop meter: 1 RTD input BS6051595Benchtop meter: 6 RTD inputBS6060495Benchtop meter: 1 thermistor input BS6061595Benchtop meter: 6 thermistor inputsMDP5000A Series$245ShownModel OS36-K-50 probe, $185See Section JShown smaller than actual sizeModel NumberPriceDescriptionDP5000-BRACKETS $7Replacement panel bracketsDP5000-SBRACKETS7Panel brackets with adjustable screwsAccessoriesModel NumberPriceDescription-9/30N/C 9 to 30 Vac/Vdc -230N/C230 VacPower OptionsOrder SuffixPriceDescription-C2$40RS-232 communicationsCommunications OptionsInputRangeIron-Constantan-200 to 1200˚C -328 to 2192˚F CHROMEGA ®- ALOMEGA ®-200 to 1372˚C -328 to 2502˚F CHROMEGA ®- Constantan -200 to 1000˚C -328 to 1832˚F Copper - Constantan-200 to 400˚C -328 to 752˚F Platinum - 10% Rhodium/ Platinum -50 to 1767˚C -58 to 3212˚F Platinum - 13% Rhodium/ Platinum -50 to 1767˚C -58 to 3212˚F OMEGA-P ®- Nicrosil -200 to 1300˚C -328 to 2372˚FOMEGA-N ®- NisilInput Ranges for DP5000 and BS6000 Series* Can be used with OS36-K-50and OS36-K-440. Also will work with OS37and OS38units with either 20:1 or 100:1 fields of view. Comes complete with power cord, mating connector(s), operators’ manual. OMEGACARE SM extended warranty program is available for models shown on this page. Ask your sales representative for full details when placing an order.Ordering Example: BS6050-C2,single RTD input benchtop thermometer and RS-232 communications, $495 + 40 = $535. OCW-1 OMEGACARE SM extends standard 3-year warranty to a total of 4 years ($53), $535 + 53 = $588J K E T S R NCANADA www.omega.ca Laval(Quebec) 1-800-TC-OMEGA UNITED KINGDOM www. Manchester, England0800-488-488GERMANY www.omega.deDeckenpfronn, Germany************FRANCE www.omega.frGuyancourt, France088-466-342BENELUX www.omega.nl Amstelveen, NL 0800-099-33-44UNITED STATES 1-800-TC-OMEGA Stamford, CT.CZECH REPUBLIC www.omegaeng.cz Karviná, Czech Republic596-311-899TemperatureCalibrators, Connectors, General Test and MeasurementInstruments, Glass Bulb Thermometers, Handheld Instruments for Temperature Measurement, Ice Point References,Indicating Labels, Crayons, Cements and Lacquers, Infrared Temperature Measurement Instruments, Recorders Relative Humidity Measurement Instruments, RTD Probes, Elements and Assemblies, Temperature & Process Meters, Timers and Counters, Temperature and Process Controllers and Power Switching Devices, Thermistor Elements, Probes andAssemblies,Thermocouples Thermowells and Head and Well Assemblies, Transmitters, WirePressure, Strain and ForceDisplacement Transducers, Dynamic Measurement Force Sensors, Instrumentation for Pressure and Strain Measurements, Load Cells, Pressure Gauges, PressureReference Section, Pressure Switches, Pressure Transducers, Proximity Transducers, Regulators,Strain Gages, Torque Transducers, ValvespH and ConductivityConductivity Instrumentation, Dissolved OxygenInstrumentation, Environmental Instrumentation, pH Electrodes and Instruments, Water and Soil Analysis InstrumentationHeatersBand Heaters, Cartridge Heaters, Circulation Heaters, Comfort Heaters, Controllers, Meters and SwitchingDevices, Flexible Heaters, General Test and Measurement Instruments, Heater Hook-up Wire, Heating Cable Systems, Immersion Heaters, Process Air and Duct, Heaters, Radiant Heaters, Strip Heaters, Tubular HeatersFlow and LevelAir Velocity Indicators, Doppler Flowmeters, LevelMeasurement, Magnetic Flowmeters, Mass Flowmeters,Pitot Tubes, Pumps, Rotameters, Turbine and Paddle Wheel Flowmeters, Ultrasonic Flowmeters, Valves, Variable Area Flowmeters, Vortex Shedding FlowmetersData AcquisitionAuto-Dialers and Alarm Monitoring Systems, Communication Products and Converters, Data Acquisition and Analysis Software, Data LoggersPlug-in Cards, Signal Conditioners, USB, RS232, RS485 and Parallel Port Data Acquisition Systems, Wireless Transmitters and Receivers。

全球首款可视红外测温仪FlukeVT02说明书

全球首款可视红外测温仪FlukeVT02说明书

全球首款可视红外测温仪Fluke VT02说明书VT02可视红外测温仪故障排查、设备巡点检、精益管理一键即可轻松搞定。

是快速发现、记录、报告问题的经济型检测工具。

VT02可视红外测温仪具有:225个点全面温度数据,实时捕捉高低温点,可见光以红外图像融合显示,只能软件存储、分析,轻便、经济。

实用。

VT02可视红外测温仪典型应用:电气连接发热、先路过载、变电设备故障、三相不平衡、开关设备、点击老化、蒸气管道泄漏、备用发电机检测、锅炉设备故障、电梯检测、制冷剂泄漏、制冷管路破损、堵塞、地暖及埋设管线、法兰及连接件渗漏、空调送风效果、冷却塔运行等等技术指标:供货商:深圳市九九仪器仪表有限公司Fluke 62 MAX可视红外测温仪现货供应FLUKE-62MAX+双旋转激光红外测温仪深圳地区供应FLUKE-62MAX+双旋转激光红外测温仪Fluke 62 MAX 和Fluke 62 MAX+红外测温仪主要优点防尘与防水:具有IP54 防护等级的防尘与防水功能。

坚固耐用:经测试能承受自 3 公尺(9.8 英呎) 处落下之冲击力。

人体工学设计:经完全重新设计,更自然贴合手部掌握。

小巧轻盈;可夹在您的工具腰带或裤耳上,亦能轻易置入工具箱内。

Fluke 62 MAX 和Fluke 62 MAX+红外测温仪其他功能远距离感测:精确的激光技术提供更精准且可重复的测量。

双激光:62 MAX+ 具备双旋转激光,可协助辨识欲测量之区域。

测量区域为介于小点之间的位置。

大型背光显示幕:大型萤幕可更轻松地查看资料,即使在暗处也不例外。

Min/Max/Avg/Dif (最小/最大/平均/差异):显示最小、最大或平均温度,或是两个测量之间的差异。

警示:「Hi」(高) 与「Lo」(低) 警示可快速显示超出限制范围的测量。

电源:62 MAX 和62 MAX+ 以单颗标准AA 电池供应电力。

Fluke 62 MAX红外测温仪规格Fluke 62 MAX温度供货商:深圳市九九仪器仪表有限公司Fluke 62 MAX+双激光可视红外测温仪现货供应FLUKE-62MAX+双旋转激光红外测温仪深圳地区供应FLUKE-62MAX+双旋转激光红外测温仪Fluke 62 MAX 和Fluke 62 MAX+红外测温仪主要优点防尘与防水:具有IP54 防护等级的防尘与防水功能。

Fluke Ti480红外热像仪说明书

Fluke Ti480红外热像仪说明书

坚固耐用,一目了然!超凡的图像质量重新定义对焦利用超像素实现起,利用而精准的图像。

焦图像针对指定目标即时获得对焦清晰的图像。

焦为与指定目标之间的距离节省时间nect®快作出决策。

通过两个实用的功能减少现场做笔记的需要:节,无需校准与全新、强大、易于使用的 Fluke Connect SmartView桌面软件。

现代视觉设计直观导航 - 轻松学习,轻松快速地使用简化的工作流程简化的报告流程和优化的报告模板Fluke Connect 云存储购买热像仪时随附 Fluke Connect SmartView® 桌面软件。

下载地址为:/FlukeConnectTI*Fluke Connect SmartView® 分析和报告软件在所有国家 / 地区均有提供,而 Fluke Connect 并非如此。

** 最佳情况和土耳其语100 % 精准对焦 – 每个对象。

近焦和远焦。

MultiSharp™ 多点对焦。

手动对焦MultiSharp TM多点对焦订购信息FLK-Ti480 9Hz 红外热像仪FLK-Ti480 60Hz 红外热像仪随机附件红外热像仪配有:标准红外镜头;交流电源和电池组充电器(含通用交流适配器);两个坚固耐用的锂离子智能电池组;USB 数据线;HDMI 视频数据线;4 GB 微型 SD 卡;结实耐用的硬质携带包;软质运输包以及可调节手带。

提供免费下载:Fluke Connect ® 桌面软件和用户手册。

可选附件FLK-LENS/TELE2 长焦红外镜头(2倍放大) FLK-LENS/4XTELE2 长焦红外镜头(4倍放大) FLK-LENS/WIDE2 广角红外镜头 TI-CAR-CHARGER 车载充电器 FLK-TI-VISOR3 遮阳板TI-TRIPOD3 三脚架安装选件 FLK-TI-BLUETOOTH 蓝牙耳机 FLK-TI-SBP3 智能电池FLK-TI-SBC3B 智能电池充电器射频连接时间(绑定时间)可能需要长达 1分钟。

Fuke TiS65红外热像仪商品介绍说明书

Fuke TiS65红外热像仪商品介绍说明书

Fluke 全优Tis00系列专门打造的性能具有显著特点,能够在问题转变为代价高昂的故障前轻松、快速地识别问题。

分辨率得到改进,能够生成您所需的图像质量,以便进行合适的诊断:•高达 2.51 倍的更高像素、•减少通过手动或固定焦距选件获得内焦距图像所需的时间•安全地存储和管理您在任何地方拍摄的图像–WiFi 上传到 Fluke Cloud –用 Fluke Cloud ™免费存储–用 Fluke Connect ®实时共享图像–可插拔 4GB 微型 SD –语音附注4•用 Fluke Connect ®从工作地点创建邮件报告,无需返回办公室处理报告IR-Fusion ® 技术可见光与红外线图像瞬时混合,结合画中画模式,可以很容易地显示问题及位置。

B1与 Fluke Ti125 25GB 免费内存。

3在供应商的无线服务区内;TiS60、TiS65 全优系列福禄克红外8种新型摄像仪。

高达 2.5 倍的1 更高像素。

分辨率TiS65 / TiS 60 260x195 D:S 417:1TiS55 / TiS 50 220x165 D:S 353:1TiS45 / TiS 40 160x120 D:S 257:1TiS20 120x90 D:S 193:1TiS10 80x60 D:S 128:1视场35.7 ° x 26.8 °完整的红外详细技术指标订货信息TiS65 30HZ 工业级商业热像仪TiS65 9HZ 工业级商业热像仪TiS60 9HZ 工业级商业热像仪 TiS55 30HZ 工业级商业热像仪TiS55 9HZ 工业级商业热像仪TiS50 9HZ 工业级商业热像仪 TiS45 30HZ 工业级商业热像仪TiS45 9HZ 工业级商业热像仪TiS40 9HZ 工业级商业热像仪TiS20 9HZ 工业级商业热像仪TiS10 9HZ 工业级商业热像仪随附标准配件:含主机、交流电源适配器、锂离子智能电池(TiS65和Tis60每台包含2个,其它型号每台包含1个)、 USB电缆、微型SD卡(TiS65、Tis60、TiS55、TiS45)、硬质携带包(TiS65、Tis60、TiS55、Tis50、TiS45、Tis40)或软质运输包、可调节手带(TiS65、Tis60、TiS55、Tis50、TiS45、Tis40)和快速参考指南以及安全数据表。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
ii
63/66/68
简介
Fluke 63、66 和 68 型红外测温仪(简称“测温仪”)用于非接触 性温度测量。测温仪通过测量物体表面辐射的红外能量来确定物体 的表面温度。请参阅图 2。
联系 Fluke
要联系 Fluke,请拨打以下任何一个电话号码: • 美国技术支持:1-800-44-FLUKE (1-800-443-5853) • 美国校准/修理:1-888-99-FLUKE (1-888-993-5853) • 加拿大: 1-800-36-FLUKE (1-800-363-5853) • 欧洲:+31 402-675-200 • 日本: +81-3-3434-0181 • 新加坡: +65-738-5655 • 世界各地: +1-425-446-5500 或者访问 Fluke 的网站 。 要注册您的产品,请访问 。 要查看、打印或下载最新手册补充资料,请访问 /usen/support/manuals。
P
符合欧盟和欧洲自由贸易联盟(EFTA)要求。
°C
摄氏度
°F
华氏度
M
~
电池
请勿将本品作为未分类的城市废弃物处理。请访 问 Fluke 网站了解回收信息。
3
63/66/68 Infrared Thermometers
图 1. 测温仪上的安全标志
ame011.eps
4
63/66/68 特点
特点
测温仪包括: • 单点激光瞄准 • MAX(最高)温度显示 • 背光显示 • 结实耐用、符合人体工学的结构 • 三脚架安装 • 硬式携带箱和腕带 • MAX(最高)、MIN(最低)、DIF(差值)、AVG(平 均)温度显示(66/68 型) • 发射率可调(66/68 型) • 高温和低温报警(66/68 型) • 数据记录(66/68 型) • 扳机锁定(66/68 型) • 探头插孔(66/68 型)
5
63/66/68 Infrared Thermometers
图 2. 红外测温仪
axk007.eps
6
显示屏
63/66/68 显示屏
A
背光“开启”符号(63/66/68 型)
ame001.eps
B
°C/°F 符号(摄氏度/华氏度)(63/66/68 型)
C
高温报警和低温报警符号(66/68 型)
显示屏(63 型) ............................................ 8 显示屏(66/68 型) ....................................... 8 按钮(66/68 型) ............................................. 9 测温仪如何工作 ................................................ 9 测温仪的操作.................................................... 10 温度测量......................................................... 10 确定热点或冷点的位置 ................................... 10 距离和光点直径.............................................. 11 观察视野......................................................... 13 发射率 ............................................................ 13 摄氏度和华氏度切换....................................... 15 扳机锁定(66/68 型) .................................... 15 背光和激光“开启/关闭”开关(63 型) ............ 16 功能按钮的功能(66/68 型) ......................... 16 选择功能(66/68 型) .................................... 17 设置高温报警、低温报警和发射率
最高温度显示(63 型)
D
MAX、MIN、DIF、AVG、HAL、LAL、PRB 温度值
(66/68 型)
E
MAX 图标(63/66/68 型) MIN、DIF、AVG、HAL、LAL、PRB 图标(66/68 型)
F
LOG(记录)图标显示数据存储的记录模式(66/68 型)
G
当前温度值(63/66/68 型)
本项保证是阁下唯一的补偿。除此以外,Fluke 不做任何明 示或默示的保证(例如保证某一特殊目的的适应性)。同 时,凡因任何原因或推测而导致的任何特别、间接、附带或 后续的损坏或损失,Fluke 也一概不予负责。由于某些州或 国家不允许对默示保证及附带或后续的损坏有所限制,故上 述的责任范围与规定对您可能并不适用。
H
SCAN(扫描)或 HOLD(保持)(63/66/68 型)
I
发射率符号和数值(63/66/68 型)
J
电池低电量和激光“启动”符号(63/66/68 型) 锁定符号(66/68 型)
7
63/66/68 Infrared Thermometers
显示屏(63 型)
在 SCAN(扫描)模式下,背光读数以摄氏度或华氏度(B)同时 显示当前温度(G)和最高温度(D)。在释放扳机和“HOLD” (保持)显示(H)后,测温仪可将最后一个读数保持 7 秒钟。
显示屏(66/68 型)
在 SCAN 模式下,同时以摄氏度或华氏度(B)显示当前温度 (G)和所选模式功能(D, E)。在释放扳机和“HOLD” (保持)显示(H)后,测温仪可将最后一个读数保持 7 秒钟。
注释 对于所有的测温仪,当电池电量不足时,会显示 ,但 测温仪将不再工作。 对于 66/68 型测温仪,扣动扳机即可启动激光和背光。按
Fluke Corporation P.O. Box 9090 Everett, WA 98206-9090 U.S.A.
Fluke Europe B.V. P.O. Box 1186 5602 BD Eindhoven The Netherlands
11/99
目录
标题
页码
简介 .................................................................. 1 联系 Fluke ........................................................ 1 安全须知 ........................................................... 2
1
63/66/68 Infrared Thermometers
安全须知
XW警告
警告说明对用户可能造成危害的状况或动作。为避免电击 或人身伤害,请遵照下列指导: • * 请勿将激光直接对准眼睛或从反射面间接照射。 • 在使用测温仪之前,请检查机壳。切勿使用损坏的
测温仪。查看是否有损坏或缺少塑胶件。 • 出现电池指示符( )时应尽快更换电池。 • 若测温仪工作失常,请勿使用。测温仪的保护措施
有限担保和有限责任
Fluke 公司保证本产品从购买日起两年内,其材料和工艺上 均无瑕疵。本项担保不包括保险丝、一次性电池或者因意 外、疏忽、误用或非正常情况下的使用或处理而损坏的产 品。经销商无权代表 Fluke 公司提供任何额外的担保。欲在 担保期内取得担保服务,请与您最近的 Fluke 授权服务中心 联系,以获取有关产品退还的授权信息,然后将产品及故障 说明寄至该服务中心。
(66/68 型) .................................................. 18
i
63/66/68 Infrared Thermometers
使用测温探头(PRB)(66/68 型).............. 18 HOLD(保持) .............................................. 19 数据存储(66/68 型) ................................... 19 调用数据(66/68 型) ................................... 19 LOG Clear(记录清除)功能......................... 19 维护.................................................................. 20 更换电池 ........................................................ 20 清洁镜头 ........................................................ 20 清洁机壳 ........................................................ 20 故障排除 .......................................................... 21 附件.................................................................. 21 CE 认证............................................................ 22 规格.................................................................. 22
相关文档
最新文档