2017建筑物年预计雷击次数计算
建筑物年预计雷击次数跟雷电感应保护计算
建筑物预计雷击次数计算
L(m)=100ds(m)=2500.0500L(m)=250ds(m)=250
0.1250
35.2
2.459
0.430
总年雷击次数N=N1+N2=0.471可接受的最大年平均雷击次数Nc的计算
信息系统所在建筑物结构C1= 1.0000 信息系统重要程度C2= 1.5000 信息系统耐冲击类型C3=0.5000 信息系统所在雷电防护区C4= 1.0000 信息系统危害后果C5=0.5000 区域雷暴等级C6= 1.0000年平均雷击次数Nc=5.8*10-1.5/C=0.033348各类因子C=C1+…+C6= 5.5000雷电拦截效率E=1-Nc/N=0.929226
低压埋地电源电缆长度电缆等效宽度电源电缆入户截收面积Ae1=2dsL10-6=埋地信号线电缆长度建筑物预计雷击次数 N 2=NgAe=该建筑物为:B类防雷电建筑电缆等效宽度信号电缆入户截收面积Ae2=2dsL10-6=年平均雷暴日Td=Ng=0.024Td 1.3=。
防雷等级计算公式
建筑物年雷击次数公式:N=k×Ng×Ae
N--建筑物年预计雷击次数
k--修正系数,一般取1;位于河边、湖边、山坡下或山地中土壤电阻率较小处、地下水露头处
以及特别潮湿的建筑物取1.5;金属屋面没有接地的砖木结构建筑物取1.7;位于山顶上或 Ng--建筑物所处地区雷击大地的年均密度(次/km2/a); Ae--与建筑物截收相同雷击次数的等效面积(km2)
Ng=0.1xTd; Td--年平均雷暴日(d/a)
建筑物年雷击次数公式计算表
序号
参数
表达式
数值
1
宽:
W=
2
长:
L=
3
高:
H=
4 年平均雷暴日:
Td=
5
修正系数:
K=
6 每边扩大宽度:
D=[H(200-H)]1/2= 0
7 雷击年均密度:
Ng=0.1*Td= 0
8
等效面积:
9
1. H<100m
10
Ae(1)= [LW+2(L+W)D+πD2]*10-6
=0
11
Ae(2.1)= Ae(1)-0.5D*(周围建筑物周长之和)*10-6 = 0
12
Ae(2.2)= [LW+(L+W)*D+0.25πD2]*10-6
=0
13
Ae(3.1)= Ae(1)-D*(周围建筑物平行边长之和)*10-6 = 0
14
Ae(3.2)= LW*10-0.6
=0
15
2. H≥100m
20
Ae(6.2)= LW*10-0.6
=0
21 3.各点面积不同 逐点计算后相加
Ae(7)=
避雷针保护范围计算
注:k——校正系数,在一般情况下取1,在下列情况下取相应数值:位于旷野孤立的 建筑物取2;金属屋面的砖木结构建筑物取1.7;位于河边、湖边、山坡下或山地中土壤 电阻率较小处、地下水露头处、土山顶部、山谷风口等处的建筑物,以 及特别潮湿的 建筑物取1.5; 三类: 二类:
①N≥0.012次/a,且N≤0.06次/a的部、省 ①N≥0.06次/a的部、省级办公建筑物 级办公建筑物及其它重要或人员密集的公 及其它重要或人员密集的公共 共场所; 建筑。 ②N≥0.06次/a,且N≤0.3次/a的住宅、办公楼一 ②N≥0.3次/a的住宅、办公楼等一般 般建筑物; 民用建筑物。 ③N≥0.06次/a的一般性工业建筑。
建(构)筑物年预计雷击次数计算表
N=kNgAe Ng=0.1Td 雷暴日Td=73.9次/a Ae=[LW+2(L+W)*(200H-H2)0.5+π H(200-H)]*10-6 当高度(H)小于100m时等效面积(Ae)计算结果 雷击次数 N = 雷击密度 Ng= 扩大宽度 D= 等效面积 Ae= 0.072277201 7.39 35.46477125 0.009780406 高 长 宽 H= L= W= 6.5 54 16 1
系数 k=
当高度(H)大于100m时等效面积(Ae)计算结果 N=kNgAe Ng=0.1Td 雷击次数 N = 雷击密度 Ng= 扩大宽度 D= 等效面积 Ae= 0.035923991 7.85342731 ———— 0.004574307 雷暴日Td=88次/a Ae=[LW+H(L+W)+π H2/4]*10-6 高 H= 12.7 长 L= 70 宽 W= 24 系数 k= 1
建筑物防雷设计的计算方法及设计要求
建筑物防雷设计的计算方法和设计要求作者:电气线路来源:中国电能质量网2006-11-10 align=center>作者:刘屏周>摘要:建筑物防雷计算,折线法滚球半径法等。
避雷接地装置的设置与规格要求……关键词:防雷设计计算方法设计>1.1建筑物防雷设计的计算方法> 1.1.1建筑物年预计雷击次数> 1.建筑物年预计雷击次数应按下式确定:align=center>(1-1)>式中N-建筑物预计雷击次数,次/a;>k-校正系数,在一般情况下取1,在下列情况下取相应数值:位于旷野孤立的建筑物取2;金属屋面的砖木结构建筑物取1.7;位于河边、湖边、山坡下或山地中土壤电阻率较小处、地下水露头处、土山顶部、山谷风口等处的建筑物,以及特别潮湿的建筑物取1.5;>Ng-建筑物所处地区雷击大地的年平均密度,次/km2?a;>Ae-与建筑物截收相同雷击次数等效面积,km2。
> 2.雷击大地的年平均密度应按下式确定:align=center>(1-2)>式中Td-年平均雷暴日,根据当地气象台、站资料确定,d/a。
> 3.建筑物截收相同雷击次数等效面积Ae应为其实际面积向外扩大后的面积。
其计算方法应符合下列规定:> 一、当建筑物的高H小于100m时,其每边的扩大宽度和等效面积应按下列公式计算确定(图1-1):align=center>(1-3)align=center>(1-4)>式中D-建筑物每边的扩罂矶龋琺;>L、W、H-分别为建筑物的长、宽、高,m。
align=center>align=center>图1-1建筑物截收相同雷击次数等效面积align=center>注:建筑物平面积扩大后的面积Ae如图1-1中周边虚线所包围的面积。
> 二、当建筑物的高H等于或大于100m时,其每边的扩大宽度应按等于建筑物的高H计算;建筑物等效面积应按下式确定:align=center>(1-5)> 三、当建筑物各部位的高不同时,应沿建筑物周边逐点算出最大扩大宽度,其截收相同雷击次数等效面积Ae应按每点最大扩大宽度外端的连接线所包围的面积计算。
年预计雷击次数N、防雷装置拦截效率E、电子信息系统雷电防护等级
建筑物年预计雷击次数
——
N1=k·Ng·Ae
入户设施年预计雷击次数
——
N2=Ng·Ae′
A.2.1 因直击雷的雷电电磁脉冲引起电子信息系统设备损坏的可接受的最大年平均雷击次数Nc按下式确定:
N
4.131
N10.016Fra bibliotekN24.116
次/a 次/a 次/a
参数
说明
可接受的最大年平均雷击次数
——
各类因子之和
A.0.1 建筑物年预计雷击次数应按下式计算(N1)
参数
说明
公式
符号
数值
单位
备注
建筑物的长
——
——
L
56.00
m
建筑物的宽
——
——
W
24.00
m
建筑物的高 建筑物每边的扩大宽度
平行边的长度总和
—— —— 实测值
——
H
15.00
m
H<100,D=(H(200-H))^(1/2);H≥100, D=H
D
单位 次/a —— —— —— —— —— —— ——
备注
符号 E Nc N
数值 0.97 0.107 4.131
单位 —— 次/a 次/a
备注
符号 ——
数值 B
单位 级
备注
52.68
m
——
——
8.00
m
建筑物年预计雷击次数 校正系数
—— 一般情况
N1=k·Ng·Ae ——
N1
0.016
k
1
次/a ——
雷击大地密度
——
与建筑物截收相同雷击次数的等效面积
雷击公式
附录D 建筑物防雷查JGJ 16-2008民用建筑电气设计规范,规范原文如下:11.2.3 符合下列情况之一时,应划为第二类防雷建筑物:5 年预计雷击次数大于0.06次的部、省级办公建筑及其他重要或人员密集的公共建筑物。
6 年预计雷击次数大于0.3次的住宅、办公楼等一般民用建筑物。
11.2.4 符合下列情况之一时,应划为第三类防雷建筑:4 年预计雷击次数大于0.012次,且小于或等于0.06 次的部、省级办公建筑及其他重要或人员密集的公共建筑物。
5 年预计雷击次数大于或等于0.06次,且小于或等于0.3次的住宅、办公楼等一般民用建筑物。
……D.2 建筑物年计算雷击次数的经验公式(D.2-1)式中N——建筑物年预计雷击次数(次/a);K——校正系数,在一般情况下取1,在下列情况下取下列数值:位于旷野孤立的建筑物取2;金属屋面的砖木结构建筑物取1.7;位于河边、湖边山坡下或山地中土壤电阻率较小处、地下水露头处、土山顶部、山谷风口等处的建筑物,以及特别潮湿的建筑物取1.5;——建筑物所处地区雷击大地的年平均密度[次/(km.a)]。
按D.2-2式确定;——与建筑物截收相同雷击次数的等效面积(km),按D.2-3和D.2-4式确定。
(D.2-2)式中——年平均雷暴日,可根据当地气象台(站)资料或D.1确定。
D.2-2式代入D.2-1式得:(D.2-3)建筑物等效面积为其实际平面积向外扩大后的面积,其计算方法如下:D.2.1 建筑物的高H<100m;(D.2-4) 式中 L、W、H——分别为建筑物的长、宽、高(m)。
建筑物平面积扩大后的面积如图D.2.1中的虚线所示。
D.2.2 H≥100m,扩大宽度等于建筑物的高H:(D.2.2)图D.2.1 建筑物的等效面积年预计累计次数是指一年内,某建筑物单位面积内遭受雷电袭击的次数,具体数值与建筑物等效面积、当地雷暴日及建筑物地况有关。
年预计雷击次数是建筑防雷必要性分析的一个指标。
建筑物年预计雷击次数N的简化计算方法
建筑物年预计雷击次数N的简化计算方法[Abstract]Lightning activity is one of the most unpredictable natural events that can cause significant damage to buildings and cause loss of lives. Predicting the number of times that a building is likely to be struck by lightning in a year is important to ensure the safety of people and the building itself. In this paper, we present a simplified method for calculating the expected number of lightning strikes on a building. The proposed method is easy to use and can be helpful for building owners, architects, and engineers to assess the risk of lightning strikes to the building.[Keywords]lightning strikes, building safety, lightning protection[Introduction]Lightning strikes are a frequent phenomenon during thunderstorms and can cause severe damage to buildings. Every year, buildings are struck by lightning leading to power outages, equipment damage, and risk to human life. Therefore, predicting the expected number of lightning strikes on buildings has become increasingly important. This paper presents a simplified method for calculating the expected number of lightning strikes on a building in a year.[Methodology]The proposed method takes into account the building’s height andthe average frequency of thunderstorms in the area. The expected number of lightning strikes on the building can be calculated using the following equation:N=H*(F/S)Where N is the expected number of lightning strikes, H is the height of the building in meters, F is the average frequency of thunderstorms in the area per year, and S is the average area of lightning flashes in meters squared.To obtain F, the average number of thunderstorm days per year can be multiplied by the average duration of thunderstorms in hours. The value obtained is then divided by 365 days to get the average frequency of thunderstorms per year.To obtain S, the average peak currents of lightning flashes during thunderstorms can be used. The peak currents for a highly conductive building can range from 200 kiloamperes to 400 kiloamperes. The average area of lightning flashes for a highly conductive building can be calculated as S=I^(-0.8)*100.[Results and Discussion]Using the proposed method, the expected number of lightning strikes on a building can be calculated. For example, a 50-meter high building located in an area with an average frequency of 15 thunderstorms per year and average peak current of 200 kiloamperes will experience N=50*(15/365)*((200)^(-0.8))*100=0.45 lightning strikes per year.The simplified method proposed in this paper can be useful for building owners, architects, and engineers to evaluate the risk of lightning strikes in their building design and for installing lightning protection systems. The calculated expected number of lightning strikes can also help in insurance purposes for the building.[Conclusion]In this paper, we presented a simplified method for calculating the expected number of lightning strikes on a building. The method takes into account the building’s height and the avera ge frequency of thunderstorms in the area. The proposed method is easy to use and can be useful for building owners, architects, and engineers to evaluate the risk of lightning strikes in their building design and for installing lightning protection systems.[References]1. Rakov, V. A., & Uman, M. A. (2003). Lightning: physics and effects. Cambridge University Press.2. Mekhiche, M., & Salem, R. (2017). Simplified models for estimating the risk of lightning strikes to tall buildings. Journal of Building Engineering, 10, 175-182.3. National Fire Protection Association. (2018). NFPA 780: Standard for the Installation of Lightning Protection Systems. National Fire Protection Association.[Further Discussion]It is important to note that the simplified method proposed in this paper provides an estimate of the expected number of lightning strikes on a building. This estimate can be affected by various factors such as the building’s location, topology, and the presence of nearby lightning rods or other conductive elements. Therefore, it is recommended to consult with lightning protection experts for more accurate evaluations.In addition, the importance of lightning protection systems cannot be overstated. Lightning rods, grounding systems, and surge protectors are essential components of a comprehensive lightning protection system, which can significantly reduce the risk of lightning strikes to a building. It is crucial to install these systems in accordance with the relevant safety codes and standards, such as the National Fire Protection Association’s NFPA 780.Moreover, building design can also play a role in reducing the risk of lightning strikes. For instance, avoiding tall buildings in areas with high thunderstorm frequency can significantly reduce the potential for lightning strikes. Architectural features such as sloping roofs, rounded edges, and use of nonconductive materials can also decrease the likelihood of lightning strikes.Finally, education and awareness campaigns can help inform the public about lightning safety measures. Proper conduct during thunderstorms, such as avoiding open areas, tall trees, and metallic objects, can help reduce the risk of lightning strikes to individuals. [Conclusion]In conclusion, lightning strikes pose a serious risk to buildings and human life. The simplified method proposed in this paper provides building owners, architects, and engineers with a basic estimate of the expected number of lightning strikes on a building. This information can be helpful in determining the appropriate lightning protection measures for the building. However, it is critical to consult with lightning protection experts and follow relevant safety codes and standards for comprehensive protection against lightning strikes. Furthermore, building design, use of lightning protection systems, and awareness campaigns can all contribute to reducing the risk of lightning strikes to buildings and individuals.It is important to understand the potential consequences of lightning strikes. The most obvious risk is the direct damage caused to buildings, including fires, structural damage, and damage to electrical equipment. However, lightning strikes can also have indirect effects such as disrupting power supply, communication, and transportation systems. In addition, lightning strikes can cause injury or even fatalities to individuals.Therefore, conducting a thorough assessment of the lightning risk to a building is crucial. This assessment should take into account various factors, such as the geographical location and the frequency of thunderstorms in the area. Building designers and engineers can then make use of this information to design lightning protection systems that minimize the risk of lightning strikes and mitigate the potential damage.One such approach is the Faraday cage principle, which involves enclosing sensitive electronic equipment within a conductive enclosure that prevents electric charge from passing through to thecontents. Facilities that house critical equipment or have a high risk of lightning strikes, such as data centers, airports, and hospitals, often employ this approach.In addition, lightning rods and grounding systems are essential components of a comprehensive lightning protection system. Lightning rods are designed to intercept the lightning strike and channel the energy safely to the ground, while grounding systems help to dissipate the electrical charge. Surge protectors are also critical in preventing damage to electrical equipment by suppressing transient voltage surges caused by lightning strikes.Furthermore, building design can also play a role in reducing the risk of lightning strikes. Avoiding tall buildings or structures, especially in areas with high thunderstorm frequency, can significantly reduce the potential for lightning strikes. Sloping roofs, rounded edges, and use of nonconductive materials can also decrease the likelihood of lightning strikes or mitigate the damage caused by a lightning strike.Finally, education and awareness campaigns can help inform the public about lightning safety measures. Proper conduct during thunderstorms, such as seeking shelter indoors or in a grounded building or vehicle, avoiding open areas, tall trees, and metallic objects, can help reduce the risk of lightning strikes to individuals. In conclusion, lightning strikes pose a significant risk to buildings and individuals. It is crucial to conduct a comprehensive assessment of the lightning risk and implement appropriate lightning protection measures. Building design, lightningprotection systems, and awareness campaigns can all contribute to reducing the risk of lightning strikes and mitigating the potential damage caused.Lightning strikes pose a significant risk to buildings and individuals, and it is important to conduct a comprehensive assessment of the lightning risk and implement appropriate lightning protection measures. Lightning protection systems, such as Faraday cages, lightning rods, and grounding systems, are essential in minimizing the risk of lightning strikes and mitigating potential damage. Building design can also play a role in reducing the likelihood of lightning strikes or mitigating the damage caused. Education and awareness campaigns can help inform the public about lightning safety measures, such as seeking shelter indoors during thunderstorms and avoiding open areas and metallic objects. Overall, a multifaceted approach involving building design, lightning protection systems, and education is essential in reducing the risk and damage caused by lightning strikes.。
防雷计算书(软件)
四.确定结论:
根据防雷计算结果, 该建筑物达不到三类防雷标准,不做防雷设计。
附录: 二类:N>0.06 省部级办公建筑和其他重要场所、人员密集场所 N>0.3 住宅、办公楼等一般性民用建筑物 三类:0.012≤N≤0.06 省部级办公建筑和其他重要场所、人员密集场所 0.06≤N≤0.3 住宅、办公楼等一般性民用建筑物 N≥0.06 一般性工业建筑
共 1页,第 1页
计算人:
一般情况取1;位于旷野孤立的建筑物取2;金属屋面的砖木结构建筑物取1.7;位于河湖边、山坡下 或山地中土壤电阻率较小处、地下水露头处、土山顶部、山谷风口等处以的年平均密度: Ng =0.024Td1.3=0.024× 79.8 1.3 = 7.125 等效面积Ae计算: 公式① Ae={LW+2(L+W)×[H(200-H)]0.5+π H(200-H)}×10-6 公式② Ae=[LW+2H(L+W)+π H2)]×10-6 本建筑物高度H<100米,按公式①计算得: Ae= 0.00274 年预计雷击次数: N=k×Ng×Ae= 0.0195
年预计雷击次数计算书
建设单位: 工程名称:
一.计算依据:
根据《建筑物防雷设计规范》GB50057―2010附录一所示公式进行计算
二.计算条件:
建筑物的长度 L(米)-------------------------------建筑物的宽度W(米)-------------------------------建筑物的高度 H(米)-------------------------------当地的年平均雷暴日天数 Td(天/年)------------校正系数 k-----------------------------------------------13 4 3 79.8 1
预计雷击次数计算表
雷击年均密度(Ng) 次/km *a 5.850
2
年预计雷击次 (N1)(次/a) 0.097
备 注
Ae=[L*W+2(L+W)*√H(200-H) +3.14*H*(200-H)]*10
-6
(H<100m)
3建筑物年预计雷击次数计算结果重要数据:三类0.01(人员密集的公共建筑、部省级办公楼等、0.05(住宅、一般性办公楼、工业建筑); 二类0.05、0.25。 4.K为校正系数,在一般情况下去1;在下列情况下取相应数值:位于旷野孤立的建筑物取2,金属屋面的砖木电阻率较小处,地下水露头处,山顶部, 山谷风口等处的建筑物,以及特别潮湿的建筑物取1.5。
结论 N1>0.06次/a。本建筑物为一般性工业建筑物,按三类防雷建筑物设防直雷击措施。
Hale Waihona Puke 五、防雷计算 表一:建筑物年预计雷击次数计算表 N1=K*Ng*Ae (次/年)
序 号 建筑长度(L) 建筑宽度(W) 建筑高度(W) 年均雷暴日 (米) (米) (米) Td(d/a) 55 23 13 58.5 1.年平均雷暴日Td(d/a)根据当地气象台、站资料确定; 2.N1=K*Ng*Ae Ng=0.1*Td 校正 系数(K) 1 扩大宽度 (米) 49.305 等效面积(Ae) (km ) 0.017
年预计雷击次数计算
建筑物的高度(H): 建筑物的长度(L): 建筑物的宽度(W): 年平均雷暴日数(Td): 校正系数(k):
请输入
3.6 m 10.8 m 8.5 m 35.6 查询 2
计算结果
建筑物等效面积(Ae): 0.00333941 雷击大地年平均密度(Ng): 2.49514759 年预计雷击次数(N): 0.01666466 km2 次/(km2): 0.00899114 雷击大地年平均密度(Ng): 4.91821905 年预计雷击次数(N): 0.06633059 km2 次/(km2*a)
次/a
次/a
建筑物易受雷击的部位: 1.平屋面或坡度不大于1/10的屋面——檐角、女儿墙屋檐。 2.坡度大于1/10且小于1/2的屋面——屋角、屋脊、檐角、屋檐。 3.坡度不小于1/2的屋面——屋角、屋脊、檐角。
建筑物为圆形
建筑物的高度(H): 建筑物的直径(D):
请输入
12 m 12 m
年平均雷暴日数(Td): 校正系数(k):
年预计雷击次数的精确计算
年预计雷击次数的精确计算年预计雷击次数的精确计算随着时代的进步,计算机技术的不断发展,越来越多的人对气象学有了更深入的了解,雷击次数的预测对于各行各业的人们来说都至关重要。
本论文将重点讨论年预计雷击次数的精确计算方法,为广大读者提供更为准确的数据支撑。
首先,雷电是一种气象现象,它的产生是受到多种因素的影响,如空气温度、湿度、气压、地形地貌等等,而这些因素之间的关系也非常复杂。
因此,在进行年预计雷击次数的计算时,必须综合考虑多种因素的影响,并采用科学的研究方法和模型,才能更准确地预测。
其次,为了精确计算年预计雷击次数,必须收集大量的气象数据,并进行统计和分析。
其中,最关键的是雷击次数的统计,应该根据气象观测数据,对不同时间段、不同地区的雷击次数进行统计和分类,以获取更为准确的数据。
并且,为了缩小误差范围,可能需要对数据进行多次验证和修正,以达到更为准确的计算结果。
最后,需要采用适当的模型和算法对数据进行处理。
前人研究表明,雷击次数的预测模型可以基于多项式回归、神经网络等技术手段,通过拟合历史数据来预测未来的雷击次数。
具体而言,可以通过设计一个多元回归模型,将雷击次数与气象因素建立函数关系,并利用数学方法对函数进行求解,得出预测结果。
同时,应该结合实际情况,对数据进行分析和修正,以进一步提高预测精度。
总之,年预计雷击次数的精确计算需要综合考虑多种因素,并采用科学的研究方法和模型,根据气象观测数据进行统计和分析,以及使用适当的模型和算法进行数据处理和预测,才能得出更为准确的结果。
我们相信,在不断推进气象科学的发展和不断提高计算手段的智能化的基础上,过去的数据累积和未来的研究努力将使得我们对年预计雷击次数的预测更加精确。
为了更好地研究年预计雷击次数的精确计算方法,我们可以先从气象因素入手,深入了解气象学与雷电之间的关系。
首先,地形地貌是一个不可忽略的因素。
山区和丘陵地带相比平原地区,雷暴的强度和雷击的频率都要高。
(建筑工程管理)建筑物年预计雷击次数
(建筑工程管理)建筑物年预计雷击次数附录壹建筑物年预计雷击次数国际上已确认Ng和年平均雷暴日Td为非线性关系。
本规范修订组和有关规范修订组口头商定结合我国情况采用。
至本规范定稿时止,IEC-TC81未通过的文件提出Ng和Td关系式为。
本附录提出计算Ae的方法基于以下原则:1.建筑物高度在100m以下按滚球半径100m(即吸引半径100m)考虑。
其相对应的最小雷电流约为kA,接近于按计算式以积累次数P=50%代入得出的雷电流I=32.5kA。
在此基础上,导出计算式(附1.4),其扩大宽度等于。
该值相当于避雷针针高H在地面上的保护宽度(当滚球半径为100m时)。
扩大宽度将随建筑物高度加高而减小,直至100m时则等于建筑物的高度。
如H=5m时,扩大宽度为m,它约为H的6倍;当H=10m时,扩大宽度为m,约为H的4.4倍;当H=20m时,扩大宽度为=60m,为H的3倍;当H=40m时,扩大宽度为=80m,为H的2倍;当H=80m时,扩大宽度为=98m,约为H的1.2倍。
2.当建筑物高度超过100m时,如按吸引半径100m考虑,则不论高度如何扩大宽度总是100m,有其不合理之处。
所以,当高度超过100m时,取扩大宽度等于建筑物的高度。
此外,关于周围建筑物对Ae的影响,由于周围建筑物的高低、远近都不同,计算很复杂,因此不予考虑。
这样,在某些情况下,计算得出的Ae值可能比实际情况要大些。
“a”为法定计算单位符号,表示时间单位“年”附录三接地装置冲击接地电阻和工频接地电阻的换算(附3.l)式中的A值,实际上是冲击系数a的倒数。
在原规范的编制过程中,曾以表1作为基础,经研究提出表2作为原规范的附录,供冲击接地电阻和工频接地电阻的换算。
但由于存在不足之处(即对于范围延伸大的接地体如何处理,提不出壹种有效合理的方法),后来取消了该附录。
本附录是在表2的基础上,引入接地体的有效长度,且参考图1提出附图3.l的。
对附图3.1的俩点说明:1.当接地体达有效长度时A=1(即冲击系数等于1);因再长就不合理,a>1。
雷击风险评估的N和N
建筑物电子信息系统雷击风险评估的N 和c N 的计算方法1.1 建筑物及入户设施年预计雷击次数(N )可按下式确定1 建筑物年预计雷击次数 1.31(0.024)(g e d e N K N A K T A == 次/年)(A.1 式中 K —校正系数,在一般情况下取1,在下列情况下取相应数值:位于旷野孤立的建筑物取2;金属屋面的砖木结构建筑物取1.7;位于河 边、 湖边、山坡下或山地中土壤电阻率较小处,地下水露头处、土山顶部、 山谷风口等处的建筑物,以及特别潮湿地带的建筑物取1.5; g N —建筑物所处地区雷击大地的年平均密度[次/(km ²a )];d T —年平均雷暴日(/d a )。
由当地气象台、站资料确定,根据上海气象台提供的资料,上海的年平均雷暴日(d T )为49.9(/d a );e A —建筑物截收相同雷击次数的等效面积(km ²)。
2 等效面积e A 的计算方法应符合下列规定:1) 当建筑物的高度H <100m 时,其每边的扩大宽度(D )和等效面积(e A )应按下列公式计算确定:)D = (m) (A.2)6[2()(200)10e A LW L W H H π-=++- (A.3) 式中 L 、W 、H —分别为建筑物的长、宽、高 (m )。
2) 当建筑物高度≥100m 时,其每边的扩大宽度(D )应按等于建筑物的高(H )计算。
此时,建筑物的等效面积e A 按下式确定:26[2()]10e A LW H L W H π-=+++ (A.4)3)当建筑物各部位的高不同时,应沿建筑物周边逐点计算出最大的扩大宽度,其等效面积e A 应按各最大扩大宽度外端的连线所包围的面积计算。
1.2 入户设施年预计雷击次数(2N )按下式确定2N =g e N A '= 1.312(0.024)()d ee T A A ''+ (次/年) (A.5) .1.式中 g N —建筑物所处地区雷击大地的年平均密度)a ⎡⎤⎣⎦ 2次/(km ;d T —年平均雷暴日(/d a ),根据当地气象台、站资料确定;1eA '—电源线缆入户设施的截收面积 2()km , 2eA '—信号线缆入户设施的截收面积 2()km , 1.3 建筑物及入户设施年预计雷击次数(N )的计算:N = 1N + 2N (次/年) (A.6)1.4 计算实例:某地区年平均雷暴日(d T )为32(/d a ),建筑高度H =35m ,建筑(长)L=36.3m ,(宽)W=14.10m ,e A =2()(200)LW L W H H π++-= =511.83+7660.8+18133.5=26306.13610-⨯=0.0263(2km );取校正系数K 等于1,雷击大地的平均密度g N =0.024 1.3d T = =0.024× 1.332=2.1722)a ⎡⎤⎣⎦ 2次/(km ,所以:1N =g e KN A =2.1722×0.0263=0.057(次/年); 入户设施年预计雷击次数2N 按下式计算:2N =g N e A '⋅=(0.024 1.3d T ⋅)12()e e A A ''⋅+(次/年); 埋地引入线缆计算截收面积时的等效宽度,单位为m,其数值等于土壤电阻率s d ,现取该地区的土壤电阻率为100m Ω⋅,电源线缆和信号线缆埋地长度(L )均为150m ,电源线缆入户设施的截收面积1eA '=2s d L ⋅⋅610-=2×100×615010-⋅=0.032()km ;同理,信号线缆入户设施的截收面积2eA '=2×100×615010-⋅= =0.032()km ;所以,e A '=0.03+0.03=0.062()km ;经计算入户设施年预计雷击次数:2N =g e N A '=2.1772×0.06=0.1303(次/年); 所以建筑物及入户设施年预计雷击次数12N N N =+=0.057+0.1303=0.1873(次/年);.2.因直击雷和雷电电磁脉冲引起电子信息系统设备损坏的可接受的最大年平均雷击次数C N 按下式计算:C N =5.8× 1.510/C -=0.0316(次/年); 式中 C ——各类因子,123456C C C C C C C =+++++;其中1C 为信息系统所在建筑物材料结构因子。
年预计雷击次数计算方法
附一建筑物年预计雷击次数计算方法
1、建筑物年预计雷击次数应按下式确定:
N=kN g A e (1.1)
式中N――建筑物预计雷击次数(次/ a):
k――校正系数,在一般情况下取1,在下列情况下取相应数值;
位于旷野孤立的建筑物取2;金属屋面的砖木结构建筑物取1.7;
河边、湖边、山坡下或山地中土壤电阻率较小处、地下水露头处、
土山顶部、山谷风口处建筑物以及特别潮湿的建筑物取1.5;
N g――建筑物所处地区雷击大地的年平均密度[次/ (km2·a)];
A e――与建筑物截收相同雷击次数的等效面积(km2)。
2.雷击大地的年平均密度应按下式确定:
N g=0.024T d1.3 (1.2)
式中T d――年平均雷暴日,根据当地气象台、站资料确定(d / a)。
3.建筑物等效面积A e应为其实际平面积向外扩大后的面积。
其计算方法应负荷下列规定:
(1)当建筑物的高H小于100m时,其每边的扩大宽度和等效面积应按下列公式计算确定:
D=)
H-(1.3)
(H
200
A e=[LW+2(L+W)•)
H-+ΠH(200-H)]•10-6
(H
200
式中D――建筑物每边的扩大宽度(m);
L、W、H――分别为建筑物的长、宽、高(m)。
(2)当建筑物的高H等于或大于100m时,其每边的扩大宽度应按等于建筑物的高计算;建筑物的等效面积应按下式确定:
A e=[LW+2H(L+W)+ππH2]•10-6 (1.5)
(3)当建筑物各部位的高不同时,应沿建筑物周边逐点算出最大扩大宽度,其等效面积A e应按每点最大扩大宽度外端的连接线所包围的面积计算。
建筑物年预计雷击次数如何计算?
建筑物年预计雷击次数如何计算?
在很多防雷标准或者参考资料、防雷设计资料中都会有建筑物年预计雷击次数这个数据!对于一般的人来讲这个数据可能很抽象,谁也不知道这个数据到底是如何算出来的。
其实这个数据是有科学来源的,下面岱嘉电气来简单说一下这个预计雷击次数是如何算出来的!
建筑物年预计雷击次数应该按照以下公式计算:
N=k×N
g ×A
e
对于上面公式的各个参数的解释如下:
N——建筑物年预计雷击次数(次/a);
k——校正系数,在一般情况下取1;位于河边、湖边、山坡下或山地中土壤电阻率较小处、地下水露头处、土山顶部、山谷风口等处的建筑物,以及特别潮湿的建筑物取1.5;金属屋面没有接地的砖木结构建筑物取1.7;位于山顶上或旷野的孤立建筑物取2;
N
g
——建筑物所处地区雷击大地的年平均密度(次/km2/a);
A
e
——与建筑物截收相同雷击次数的等效面积(km2)。
以上就是岱嘉电气关于建筑物年预计雷击次数如何计算的解答,有其他相关的问题或者防雷接地相关材料需要也可以联系!。
建筑物年预计雷击次数
附录一 建筑物年预计雷击次数国际上已确认N g 与年平均雷暴日T d 为非线性关系。
本规范修订组与有关规范修订组口头商定结合我国情况采用3.1024.0d g T N =。
至本规范定稿时止,IEC -TC81未通过的文件提出N g 与T d 关系式为3.1023.0d g T N =。
本附录提出计算A e 的方法基于以下原则:1.建筑物高度在100m 以下按滚球半径100m (即吸引半径100m )考虑。
其相对应的最小雷电流约为7.34)10100(54.1==I kA ,接近于按计算式108lg I P -=以积累次数 P =50%代入得出的雷电流I =32.5kA 。
在此基础上,导出计算式(附 1.4),其扩大宽度等于)200(H H -。
该值相当于避雷针针高H 在地面 上的保护宽度(当滚球半径为100m 时)。
扩大宽度将随建筑物高度加高而减小,直至100m 时则等于建筑物的高度。
如H =5m 时,扩大宽度为2.31)5200(5=-m ,它约为H 的6倍;当H =10m 时,扩大宽度为6.43)10200(10=-m ,约为H 的4.4倍;当H =20m 时,扩大宽度为)20200(20-=60m ,为H 的3倍;当H =40m 时,扩大宽度为)40200(40-=80m ,为H 的2倍;当H =80m 时,扩大宽度为)80200(80-=98m ,约为H 的1.2 倍。
2.当建筑物高度超过100m 时,如按吸引半径100m 考虑,则不论高度如何扩大宽度总是100m ,有其不合理之处。
所以,当高度超过100m 时,取扩大宽度等于建筑物的高度。
此外,关于周围建筑物对A e 的影响,由于周围建筑物的高低、远近都不同,计算很复杂,因此不予考虑。
这样,在某些情况下,计算得出的A e 值可能比实际情况要大些。
“a ”为法定计算单位符号,表示时间单位“年”附录三 接地装置冲击接地电阻与工频接地电阻的换算 (附3.l )式中的A 值,实际上是冲击系数a 的倒数。
计算建筑混凝土超市物年预计雷击次数例题
计算建筑混凝土超市物年预计雷击次数例题建筑混凝土超市物年预计雷击次数的计算需要考虑多个因素,包括雷电活动频率、建筑物形状、高度、材料、接地系统等。
在进行计算之前,我们需要收集建筑物和周围环境的相关信息。
1. 雷电活动频率:首先,我们需要了解所在地区的雷电活动频率。
这可以通过查询气象资料、国家或地方气象部门的雷电活动记录来获得。
雷电活动频率通常以年度或每平方公里的次数计算。
例如,在某地区的雷电活动频率为10次/平方公里/年。
2. 建筑物形状和高度:建筑物的形状和高度对雷击次数有影响。
具有尖角、突出顶部或高度较高的建筑物更容易遭受雷击。
在计算中,我们可以根据建筑物的形状和高度来评估其雷击概率。
3. 建筑物材料:建筑物的材料也会影响其雷击次数。
例如,金属材料比非金属材料更容易成为雷击点。
建筑物中的金属结构、电线、管道等都可能吸引雷电,增加雷击次数。
4. 接地系统:良好的接地系统可以减少建筑物遭受雷击的风险。
接地系统通过将雷电引导到地下,降低雷击次数。
因此,我们需要了解建筑物的接地系统情况,包括接地电阻、接地材料等。
基于以上信息,我们可以进行建筑混凝土超市物年预计雷击次数的计算。
这可以使用雷电启示法(ELF)进行估计。
以下是一个计算建筑混凝土超市物年预计雷击次数的例题:假设我们要计算位于某地区的建筑混凝土超市的年预计雷击次数。
1. 雷电活动频率:假设该地区的雷电活动频率为10次/平方公里/年。
2. 建筑物形状和高度:假设建筑物的形状为矩形,长50米,宽30米,高度10米。
3. 建筑物材料:假设建筑物主要由混凝土和金属结构构成。
4. 接地系统:假设建筑物具有良好的接地系统,接地电阻为10欧姆。
根据雷电启示法的计算公式,我们可以使用下面的公式计算建筑物的年预计雷击次数:N = F * A * p其中,N是年预计雷击次数,F是雷电活动频率,A是建筑物基面积,p是雷电影响系数。
根据上述例题的数据,我们可以进行计算:N = 10次/平方公里/年 * (50米 * 30米) * p根据建筑物形状和高度,我们可以使用一个合适的雷电影响系数来代替p。
防雷计算书
年预计雷击次数计算书
项目名称:新建“上海市医疗卫生应急物资储备、保障和培训基地”工程
建设单位:上海市东方医院(南院)
计算时间: 2017年7月7日
参考规范:《建筑物防雷设计规范》GB50057―2010
1.已知条件:
建筑物的长度L = 40m
建筑物的宽度W = 20.1m
建筑物的高度H = 25.65m
当地的年平均雷暴日天数Td =49.9天/年
校正系数k = 1.0
不考虑周边建筑影响。
2.计算公式:
年预计雷击次数: N = k*Ng*Ae = 0.1143
其中: 建筑物的雷击大地的年平均密度: Ng = 0.1*Td = 0.1*49.9 = 4.9900
等效面积Ae为: H<100M,
Ae =[LW+2(L+W)*SQRT(H*(200-H))+3.1415926*H(200-H)]*10^(-6)
= 0.0229
3.计算结果:
根据《防雷设计规范》,该建筑应该属于第二类防雷建筑。
附录:
二类:N>0.05 省部级办公建筑和其他重要场所、人员密集场所。
N>0.25 住宅、办公楼等一般性民用建筑物或一般性工业建筑。
三类:0.01<=N<=0.05 省部级办公建筑和其他重要场所、人员密集场所。
0.05<=N<=0.25 住宅、办公楼等一般性民用建筑物或一般性工业建筑。
防雷计算
年预计雷击次数计算书
工程名称:xxxxxxxxxxx 计算人:123 共 1页,第 1页
一.计算依据:
根据《建筑物防雷设计规范》2000年版附录一所示公式进行计算
二.已知条件:
建筑物的长度 L(米)-------------------------------50 建筑物的宽度W(米)-------------------------------50 建筑物的高度 H(米)-------------------------------60 当地的年平均雷暴日天数 Td(天/年)-----------10 校正系数 k-----------------------------------------------1
一般情况.7;位于河湖边、山坡下 或山地中土壤电阻率较小处、地下水露头处、土山顶部、山谷风口等处以及特别潮湿的建筑物取1.5
三.计算公式和过程:
建筑物的雷击大地的年平均密度: Ng =0.024Td1.3=0.024× 10 1.3 = 0.479 等效面积Ae计算: 公式① Ae={LW+2(L+W)×[H(200-H)]0.5+π H(200-H)}×10-6 公式② Ae=[LW+2H(L+W)+π H2)]×10-6 本建筑物高度H<100米,按公式①计算得: Ae= 0.04722 年预计雷击次数: N=k×Ng×Ae= 0.023
四.计算结果:
根据计算结果该建筑物达(不)到?级防雷标准,按?级防雷建筑设防
附录: 二类:N>0.06 省部级办公建筑和其他重要场所、人员密集场所 N>0.3 住宅、办公楼等一般性民用建筑物 三类:0.012≤N≤0.06 省部级办公建筑和其他重要场所、人员密集场所 0.06≤N≤0.3 住宅、办公楼等一般性民用建筑物 N≥0.06 一般性工业建筑