怎么样在AIX上安装 卸载Powerpath(for EMC Storage)
怎么样在AIX上安装/卸载Powerpath(for EMC Storage)1、检查所需要的文件集Powerpath4.3以上要求 5.1.0.58以上,devices.fcp.disk.rte 5.2.0.17以上检查文件集# lslpp -l devices.fcp.disk.rteFileset Level State Description----------------------------------------------------------------------------Path: /usr/lib/objreposdevices.fcp.disk.rte 5.2.0.60 APPLIED FC SCSI CD-ROM, Disk,Read/Write Optical DeviceSoftware 5.2.0.60 APPLIED Common PCI FC Adapter DeviceSoftwarePath: /etc/objreposdevices.fcp.disk.rte 5.2.0.60 APPLIED FC SCSI CD-ROM, Disk,Read/Write Optical DeviceSoftware 5.2.0.60 APPLIED Common PCI FC Adapter DeviceSoftware对应的补丁要求(仅仅针对5.2版本)#instfix -a -ivk IY60183IY60183 Abstract: Open failure on ESS with FC df1000fa adapterIY60183 Symptom Text:Customer sees open failures to FC attached disks across aMcData or Cisco switch. I/O hangs.across the FC adapter.----------------------------Fileset :5.2.0.42 is applied on the system.Fileset devices.pci.df1000fa.rte:5.2.0.1 is applied on the system.All filesets for IY60183 were found.#instfix -a -ivk IY62117IY62117 Abstract: I/O hang after 1 second cable pull and recovery IY62117 Symptom Text:The customer will notice I/Os hanging or I/Os not recovering.In the error log, there will be logs on the fcs deviceindicating link may have gone down and may have come up, andIOCB timeouts and error logs on fscsi device indicating NPORTlogin timouts, and target reset timeouts, etc.----------------------------Fileset :5.2.0.43 is applied on the system.All filesets for IY62117 were found.2、安装agent,先解压agent软件注意:Agent的软件要求版本最好与存储本身的软件版本一致。
安装PowerPath的集群AIX平台使用EMC磁盘系统注意事项 v1.2
安装PowerPath的集群AIX平台使用EMC磁盘系统注意事项2006年11月EMC技术解决方案部版本记录版权说明本文件中出现的任何文字叙述、文档格式、插图、照片、方法、过程等内容,除另有特别注明,版权均属美国EMC 公司所有,受到有关产权及版权法保护。
任何个人、机构未经美国EMC公司的书面授权许可,不得复制、引用或传播本文件的任何片断,无论通过电子形式或非电子形式。
目录1安装POWERPATH的集群AIX平台使用EMC SYMMETRIX磁盘注意事项 (4)1.1在HACMP中设置EMCPOWERRESET以及BREAK RESERVES IN PARALLEL =TRUE (4)1.2LV S TRIPING (5)2安装POWERPATH的集群AIX平台使用EMC CLARIION磁盘注意事项 (6)2.1在HACMP中设置EMCPOWERRESET以及BREAK RESERVES IN PARALLEL =TRUE (6)2.2在HACMP+P OWER P ATH环境中设置CFGSCSI_ID以提高HACMP启动和切换速度 (7)2.3LV S TRIPING (9)1 安装PowerPath的集群AIX平台使用EMC Symmetrix磁盘注意事项1.1 在HACMP中设置emcpowerreset以及break reserves in parallel =true为保证HACMP能够顺利切换并且最大限度地加快切换速度, 需要在HACMP配置中遵循以下指导:For HACMP 5.1 and higher (SMIT)1. Enter into the SMIT fastpath for HACMP "smitty hacmp".2. Select Extended Configuration.3. Select Extended Resource Configuration.4. Select HACMP Extended Resources Configuration.5. Select Configure Custom Disk Methods.6. Select Add Custom Disk Methods.7. The following fields are available, enter as follows;For IBM Fibre Channel configurations with PowerPath 3.0.3 and higher:Disk Type (PdDvLn field from CuDv) = disk/pseudo/powerMethod to identify ghost disks = SCSI3Method to determine if a reserve is held = SCSI_TURMethod to break a reserve = /usr/lpp/EMC/Symmetrix/bin/emcpowerresetBreak reserves in parallel = trueMethod to make the disk available = MKDEV8. Configure the same custom disk processing method on each node in the cluster and synchronize the cluster resources. The cluster verification process ensures that the method that you configured exists and is executable on all nodes. The synchronization process ensures that the ODM entries are the same on all nodes, but will not synchronize the methods named in the ODM entries.Note To help insure emcpowerreset is installed and configured correctly, go to "/etc/objrepos" and enter the command "odmget HACMPdisktype". If installed correctly you should see "emcpowerreset" called on the "breakres" line. See example below:HACMPdisktype:PdDvLn = "disk/pseudo/power"ghostdisks = "SCSI3"checkres = "SCSI_TUR"breakres = "/usr/lpp/EMC/Symmetrix/bin/emcpowerreset"parallel = "true"makedev = "MKDEV"reserved1 = ""reserved2 = ""reserved3 = ""In addition, after a failover, you can look at the "hacmp.out" file and confirm emcpowerreset appears for the FC Path and/or hdisk entry. See example below:Clar_Cascade_1:cl_disk_available[13] ckres_rc=2Clar_Cascade_1:cl_disk_available[13] [[ 2 != 0 ]]Clar_Cascade_1:cl_disk_available[29]/usr/lpp/EMC/CLARiiON/bin/emcpowerreset fscsi1 hdiskpower38Clar_Cascade_1:cl_disk_available[1228] echoClar_Cascade_1,Clar_Cascade_1 Clar_Cascade_1:cl_disk_available[1228]read vg注: 从HACMP V5.4开始, 无需配置使用“emcpowerreset”1.2 LV StripingEMC强烈建议在条件许可的情况下, 在主机层面进行LV Striping设置以提高IO性能. 通常Striping宽度为4的倍数, 深度取决于客户应用的IO Size, 一般可取32k.2 安装PowerPath的集群AIX平台使用EMC Clariion磁盘注意事项2.1 在HACMP中设置emcpowerreset以及break reserves in parallel =true为保证HACMP能够顺利切换并且最大限度地加快切换速度, 需要在HACMP配置中遵循以下指导:For HACMP 5.1 and higher (SMIT)1. Enter into the SMIT fastpath for HACMP "smitty hacmp".2. Select Extended Configuration.3. Select Extended Resource Configuration.4. Select HACMP Extended Resources Configuration.5. Select Configure Custom Disk Methods.6. Select Add Custom Disk Methods.7. The following fields are available, enter as follows;For IBM Fibre Channel configurations with PowerPath 3.0.3 and higher:Disk Type (PdDvLn field from CuDv) = disk/pseudo/powerMethod to identify ghost disks = SCSI3Method to determine if a reserve is held = SCSI_TURMethod to break a reserve = /usr/lpp/EMC/Symmetrix/bin/emcpowerresetBreak reserves in parallel = trueMethod to make the disk available = MKDEV8. Configure the same custom disk processing method on each node in the cluster and synchronize the cluster resources. The cluster verification process ensures that the method that you configured exists and is executable on all nodes. The synchronization process ensures that the ODM entries are the same on all nodes, but will not synchronize the methods named in the ODM entries.Note To help insure emcpowerreset is installed and configured correctly, go to "/etc/objrepos" and enter the command "odmget HACMPdisktype". If installed correctly you should see "emcpowerreset" called on the "breakres" line. See example below:HACMPdisktype:PdDvLn = "disk/pseudo/power"ghostdisks = "SCSI3"checkres = "SCSI_TUR"breakres = "/usr/lpp/EMC/Symmetrix/bin/emcpowerreset"parallel = "true"makedev = "MKDEV"reserved1 = ""reserved2 = ""reserved3 = ""In addition, after a failover, you can look at the "hacmp.out" file and confirm emcpowerreset appears for the FC Path and/or hdisk entry. See example below:Clar_Cascade_1:cl_disk_available[13] ckres_rc=2Clar_Cascade_1:cl_disk_available[13] [[ 2 != 0 ]]Clar_Cascade_1:cl_disk_available[29]/usr/lpp/EMC/CLARiiON/bin/emcpowerreset fscsi1 hdiskpower38Clar_Cascade_1:cl_disk_available[1228] echoClar_Cascade_1,Clar_Cascade_1 Clar_Cascade_1:cl_disk_available[1228]read vg注: 从HACMP V5.4开始, 无需配置使用“emcpowerreset”2.2 在HACMP+PowerPath环境中设置cfgscsi_id以提高HACMP启动和切换速度注1:在Symmetrix环境中不需要设置此脚本,而在Clariion环境中需要设置此脚本。
powerpath各个系统安装emc存储
powerpath各个系统安装emc存储AIX系统:1 用Telnet工具登录至AIX主机。
2 进入PowerPath安装包所在的目录,解压缩PowerPath安装包:# gunzip EMCPower.AIX.5.5.0.3.GA.tar.gz# tar xvf EMCPower.AIX5.5.0.3.GA.tar3 使用installp命令安装组件:# installp –agXd. EMCpower4 使用powermt config命令执行一些管理配置:# powermt config5 使用PowerPath注册工具注册授权许可:# emcpreg –install6 确认产品注册信息:# powermt check_registration7 使用SMIT工具配置PowerPath设备:# smitty powerpath8 退出SMIT后,PowerPath就已安装并完成配置。
9 现在安装PowerPath Viewer组件,进入PowerPath Viewer下载目录:# gunzip EMCPower.MgmtComponent.AIX.5.5.b006.tar.gz # tar -xvf EMCPower.MgmtComponent.AIX.5.5.b006.tar10 使用installp命令安装组件:# installp –agXd. EMCpower.MgmtComponent11 打开编辑器完成配置:# /etc/emc/bin/emcp_mond_edit12 默认Management Component是被禁用的,要启用它输入1。
13 保存并激活更改的设定输入13。
14 选择选项1保存配置,重启进程并退出。
全部安装完成。
HP-UX系统:1 用Telnet工具登录至HP-UX主机。
2 进入PowerPath安装包所在的目录,解压缩PowerPath安装包:# gunzip EMCPower.HPUX.PI.5.1.2.GA.b113.tar.gz3 使用swinstall命令安装PowerPath:# swinstall –x autoreboot=true –x mount_all_filesystems=false –s /software/PowerPath/ EMCPower.HPUX.PI.5.1.SP2.GA.b113.tar EMCpower注1:请设定绝对路径。
AIX连接EMC存储及交换机
AIX连接EMC存储及交换机⽬录第⼀章、概述 (2)1.1编写内容 (2)1.2项⽬概述 (2)第⼆章、物理环境的安装 (2)2.1物理机的布署 (2)2.2光纤线连接图 (3)第三章、DS300B交换机划分zone (4)3.1交换机wwn别名绑定 (4)3.2通过远程telnet查看其中⼀台zone (5)第四章、AX04-5 EMC存储端的配置 (6)4.1存储端控制器对应IP (6)4.2存储端的配置 (7)4.2.1.存储的登录 (7)4.2.2创建Raid组 (7)4.2.3.新建⼀个lun (9)4.2.4删除⼀个lun (9)4.2.5主机向存储系统的注册 (10)4.2.6建⽴STORAGE GROUP (12)第五章、P550 IBM⼩机软件的安装 (14)5.1.odm的安装 (14)5.2.powerpath的安装 (15)5.3光纤卡的模式 (17)第六章、存储端lun的挂载 (17)6.1给Storage Group挂载lun (17)6.2给Storage Group添加主机 (18)第七章、服务器端lun的发现及配置 (18)7.1主机认盘 (18)7.2powerpath维护操作 (19)7.3lun的格式化和使⽤ (19)7.3.1创建卷组vg (19)7.3.2建⽴逻辑卷LV (20)7.3.3建⽴⽂件系统 (21)第⼋章、⽇常管理和维护 (22)8.1开机前注意事项 (22)8.2开机步骤 (22)8.3开机完成 (22)8.4磁盘阵列关机步骤 (23)附录23第⼀章、概述1.1编写内容本⽂档描述了EMC AX04-5存储,EMC300B交换机的配置,IBM P550服务器的AIX操系统连接存储主机端和存储端的安装及配置流程。
1.2项⽬概述根据客户的要求,把原有的6台AX4-5存储重新划分lun,每个存储做4个raid5组(每个raid组由5个硬盘组成),每个组⾥⾯划分4个lun(3个lun是1TB,其中⼀个lun是595GB)。
用于 AIX 的 CLARiiON iSCSI 服务器安装指南
用于AIX的EMC CLARiiON iSCSI服务器安装指南P/N300-005-049修订版A032008年5月30日本文档介绍如何在服务器上配置iSCSI启动器端口和设置iSCSI安全,这些服务器与CX4UltraFlex TM系列、CX3UltraScale TM系列、CX系列以及AX4–5系列存储系统上的iSCSI数据端口相连。
建议您将本指南与Powerlink网站上提供的下列指南之一结合使用:存储系统安装指南(带有Navisphere Express的AX4–5系列、CX4系列、CX3系列或CX系列存储系统)安装指南(P/N069001166)(带有Navisphere Manager的AX4–5系列、CX4系列、CX3系列或CX系列存储系统)重要信息目前仅支持网络接口卡(NIC)。
有关支持的操作系统版本、驱动程序类型或功能的详细信息,请参阅Powerlink网站上的E-Lab™互操作性Navigator(针对CX4系列、CX3系列或CX系列存储系统),以及存储系统技术支持网站“安装”页上的“支持列表”链接(针对AX4-5系列或AX系列存储系统)。
本文档包括以下主题:准备工作 (2)iSCSI服务器设置过程概述 (4)为NIC或iSCSI HBA分配IP地址 (5)在AIX服务器上配置iSCSI软件启动器 (7)定义NIC的iSCSI目标 (8)配置对iSCSI目标设备的访问 (9)准备使用CHAP安全 (10)在iSCSI启动器上配置CHAP (11)1准备工作使用本指南在服务器上设置iSCSI启动器端口或设置iSCSI安全(挑战握手认证协议-CHAP)之前,您必须:按照存储系统设置指南或安装指南(仅限带有Navisphere Manager的存储系统)中的说明配置存储系统iSCSI端口。
完成存储系统附带的或从存储系统技术支持网站定制生成的存储系统配置规划指南中的工作表。
对于AX4-5系列,可使用存储系统技术支持网站“安装”页上的“规划”链接生成规划指南。
emc存储操作手册
emc存储操作手册EMC存储操作手册是为了帮助用户了解和使用EMC存储设备而编写的指南。
本手册旨在提供详细的操作说明和注意事项,以帮助用户有效地管理和维护存储系统。
1. EMC存储系统概述EMC存储系统是一种专业的数据存储设备,广泛应用于企业、机构和云计算等领域。
它具有高性能、高可靠性和高可用性的特点,可以满足不同规模和业务需求的存储需求。
2. 硬件和软件环境准备在开始操作EMC存储设备之前,需要确保硬件和软件环境的准备工作已经完成。
包括:安装和连接存储设备、配置网络环境、安装存储管理软件等。
3. 存储设备初始化存储设备初始化是指在首次使用存储设备前,对设备进行一系列初始化设置,包括创建存储池、设置RAID级别、配置存储卷等。
这些设置决定了存储设备的性能和可靠性。
4. 存储卷管理存储卷是用户进行数据存储和访问的逻辑单元,用户可以根据实际需求创建、删除、扩容和迁移存储卷。
此外,还需要了解存储卷的访问控制和权限设置。
5. 数据备份与恢复数据备份与恢复是存储系统管理的重要环节,通过定期备份数据可以避免数据丢失的风险。
EMC存储设备提供多种备份策略和工具,用户可以根据需求选择合适的备份方式,并学会进行数据恢复。
6. 存储性能监控和调优EMX存储设备具有强大的性能监控和调优功能,可以实时监测存储设备的性能指标,并提供性能分析和调优建议。
用户可以根据监控结果进行性能优化,提升存储系统的效率和响应速度。
7. 存储故障排除在使用存储设备过程中,可能会遇到各种故障和问题。
EMC存储操作手册提供了常见故障的排查方法和解决方案,帮助用户快速定位和解决问题,保证存储系统的正常运行。
8. 存储设备维护和升级存储设备维护包括固件升级、驱动程序更新和硬件维护等工作。
用户应定期检查和维护存储设备,确保设备的稳定性和安全性,同时根据厂商的推荐升级存储设备的软件和固件。
9. 安全管理存储设备中的数据对于企业来说通常是非常重要和敏感的,因此安全管理至关重要。
emc存储操作手册
emc存储操作手册EMC存储是一种强大的数据存储解决方案,被广泛应用于企业和数据中心环境中。
本操作手册将向您介绍如何正确操作EMC存储器,以及如何管理和维护存储系统。
请按照以下步骤进行操作,并务必遵循相关指导建议,以保证您的数据安全和系统的正常运行。
1. EMC存储基础知识在正式开始操作EMC存储之前,必须了解一些基础知识。
首先,了解存储系统的架构和组件,包括存储控制器、存储设备和主机连接等。
其次,熟悉EMC存储器的命令行界面及其基本操作,在本操作手册中,我们将主要使用命令行界面进行操作。
2. 连接存储系统在使用EMC存储器之前,需要正确连接存储控制器和主机。
确保存储器与主机之间的网络连接正常,并确保使用正确的IP地址和端口。
在连接过程中,您可能需要根据具体情况进行一些配置,比如设置主机的HBA和存储器的端口参数等。
3. 创建存储池存储池是EMC存储器中用于存储数据的逻辑容器。
在使用存储器之前,首先需要创建一个或多个存储池。
您可以根据实际需求创建不同的存储池,比如按业务类型或性能需求划分。
创建存储池时,需要指定容量、性能和数据保护等级等参数。
4. 创建逻辑单元逻辑单元是存储池中的逻辑分区,用于存储和管理数据。
在创建逻辑单元之前,需要确定逻辑单元的容量大小和访问控制策略。
在创建逻辑单元时,还可以设置一些其他属性,比如快照和克隆等。
5. 主机连接在将存储器与主机连接之前,需要确保主机操作系统已经安装了正确的驱动程序,并配置了适当的主机连接。
将主机与存储器连接后,还需要在主机上执行一些必要的配置,比如扫描存储器逻辑单元和分配逻辑单元给主机等。
6. 数据备份和恢复对于企业来说,数据备份和恢复至关重要。
EMC存储器提供了多种数据保护功能,可以帮助您实现可靠的数据备份和灾难恢复。
在本操作手册中,我们将介绍备份和恢复的基本操作,并提供一些建议和注意事项。
7. 性能优化和故障排除当存储系统出现性能问题或故障时,需要及时进行优化和排除。
EMC存储系统安装配置手册
EMC存储系统安装配置手册目录第1章概述_________________________________________________________________ 61.1编写目的______________________________________________________________________ 6 1.2参考文档______________________________________________________________________ 7第2章存储硬件安装_________________________________________________________ 82.1EMC CX3中端磁盘阵列安装配置________________________________________________ 8第3章存储软件安装配置_____________________________________________________ 93.1整体说明______________________________________________________________________ 93.2IBM AIX平台软件安装__________________________________________________________ 93.2.1IBM pSeries 安装需求____________________________________________________________ 93.2.2ODM安装_______________________________________________________________________ 113.2.3PowerPath的安装 _______________________________________________________________ 163.2.3.1PowerPath5.0.0安装需求_______________________________________________________ 163.2.3.2PowerPath5.0.0安装流程_______________________________________________________ 163.2.4Navisphere Agent/Cli的安装_____________________________________________________ 193.2.4.1安装需求____________________________________________________________________ 193.2.4.2安装流程____________________________________________________________________ 193.2.5HACMP相关设置 ________________________________________________________________ 233.2.5.1提示:______________________________________________________________________ 233.2.5.2Set emcpowerreset in HACMP_________________________________________________ 233.2.5.3Add “cfgscsi_id” to HACMP(for CX3) ___________________________________________ 233.2.6常用命令 ________________________________________________________________________ 253.2.7IBM AIX主机识别PowerPath管理的设备___________________________________________ 263.3Redhat Linux平台软件安装____________________________________________________ 273.3.1PowerPath安装 _________________________________________________________________ 273.3.1.1安装需求____________________________________________________________________ 273.3.1.2安装流程____________________________________________________________________ 283.3.2Navisphere Agent/Cli安装_______________________________________________________ 283.3.2.1安装需求____________________________________________________________________ 283.3.2.2安装流程____________________________________________________________________ 293.3.3Linux主机识别PowerPath管理的设备 _____________________________________________ 293.4Windows2003平台软件安装 ___________________________________________________ 303.4.1PowerPath安装 _________________________________________________________________ 303.4.1.1安装需求____________________________________________________________________ 303.4.1.2安装流程____________________________________________________________________ 303.4.2Navisphere Agent/Cli安装_______________________________________________________ 383.4.2.1安装需求____________________________________________________________________ 383.4.2.2安装流程____________________________________________________________________ 383.4.3Windows主机识别PowerPath管理的设备_________________________________________ 47 3.5HP-UX平台软件安装 __________________________________________________________ 493.5.1PowerPath的安装 _______________________________________________________________ 493.5.1.1PowerPath5.0.1安装需求_______________________________________________________ 493.5.1.2PowerPath5.0.0安装流程_______________________________________________________ 50 3.5.2Navisphere Agent/Cli的安装_____________________________________________________ 543.5.2.1安装需求____________________________________________________________________ 543.5.2.2安装流程____________________________________________________________________ 54 3.5.3HPUX基本连接和认盘操作 ________________________________________________________ 56 3.5.4HP-UX主机识别PowerPath管理的设备 ____________________________________________ 583.6在HPUX和MCSG中使用认到的磁盘 ___________________________________________ 59 3.6.1单机环境下使用到的磁盘 __________________________________________________________ 593.6.2在MC/SG中使用认到的盘,并在其它主机上IMPORT VG________________________________ 613.7PP在HPUX平台使用Clariion磁盘创建LVM注意事项:_________________________ 62 3.7.1设置PV TIMEOUT值为180 _______________________________________________________ 62 3.7.2设置LV参数BBR为NONE _______________________________________________________ 62 3.7.3LV Striping_____________________________________________________________________ 623.8CX3Storage Group配置______________________________________________________ 63第1章概述1.1 编写目的本文档描述了EMC CX3中端磁盘阵列、Brocade 48000光纤交换机的硬件安装及配置流程;IBM AIX、HP-UX、Linux、Windows等相关操作系统连接EMC磁盘阵列时主机端软件的安装以及配置流程。
AIX中关于EMC存储的相关命令
AIX中关于EMC存储的相关命令#powermt display dev=all这个是常用命令,通过它你可以看到以下信息Pseudo name=hdiskpower1 (你在主机上看到的power盘)CLARiiON ID=CK200031****** [HR SG](存储上的组别)Logical device ID=60060167EB0C000022A83E3908C3D711 [LUN 1](逻辑单元号)state=alive; (状态不错^_^)policy=CLAROpt;(中档产品)()priority=0;queued-IOs=0Owner: default=SP A, current=SP A(当前控制器spA)=================================================================== ===========---------------- Host --------------- - Stor - -- I/O Path - -- Stats ---### HW Path I/O Paths Interf. Mode State Q-IOs Errors=================================================================== ===========0 fscsi0 hdisk10 SP B1 active alive 0 01 fscsi1 hdisk17 SP B0 active alive 0 01 fscsi1 hdisk24 SP A1 active alive 0 00 fscsi0 hdisk3 SP A0 active alive 0 0#lspv(呵呵,这个命令很常用吧)在这里看到主机识别到的所有存储上的盘,对应的vg。
hdiskpower0 005f2c6aa2851229 vg1hdiskpower1 005f2c6aa284d3ce vg1hdiskpower2 005f2c7aa2c86899 vg2hdiskpower3 005f2c6aa30fbe31 vg2hdiskpower4 005f2c7aa2c69692 vg3 activehdiskpower5 005f2c6aa309468d vg4 activehdiskpower6 005f2c6aa3101de2 vg4 active# lspv hdiskpower1PHYSICAL VOLUME: hdiskpower1 VOLUME GROUP: h85vg1PV IDENTIFIER: 005f2c6aa284d3ce VG IDENTIFIER 005f2c6a00004c000000010e b353ee73PV STATE: activeSTALE PARTITIONS: 0 ALLOCATABLE: yesPP SIZE: 128 megabyte(s) LOGICAL VOLUMES: 1TOTAL PPs: 799 (102272 megabytes) VG DESCRIPTORS: 1FREE PPs: 0 (0 megabytes) HOT SPARE: noUSED PPs: 799 (102272 megabytes)FREE DISTRIBUTION: 00..00..00..00..00USED DISTRIBUTION: 160..160..159..160..160同样的方法就可以查到主机识别到的所有存储lun的大小了。
AIX主机挂接EMC CLARiiON磁盘阵列要点
1.AIX5.2操作系统检查1,安装为5.2版本,操作系统补丁最新#oslevel -r输出如:5200 07#instfix –i | grep AIX输出如:所有的文件集可以找到All filesets for 5.2.0.0_AIX_ML were found.All filesets for 5200-01_AIX_ML were found.All filesets for 5200-02_AIX_ML were found.All filesets for 5200-03_AIX_ML were found.All filesets for 5200-04_AIX_ML were found.All filesets for 5200-05_AIX_ML were found.All filesets for 5200-06_AIX_ML were found.All filesets for 5200-07_AIX_ML were found.2,32位内核(具体说明参见附件)#bootinfo–K输出:323,需要将manual安装上,便于查看系统命令的使用方法。
#man ls有输出ls的用法4,检查时区,时间(见下文所述)#date输出时间、时区正确(北京时区),如:Mon Jan 23 10:47:24 BEIST 2006 5,机器名称、ip、网关、已经网卡的状态、网络通信是否有丢包#hostname对照安装要求检查#netstat -in按照安装要求检查ip#smitty tcpip检查默认网关配置#ping 另外一台机器的bootip、standby ip,看是否有丢包6,文件系统大小#df –g输出如:Filesystem GB blocks Free %Used Iused %Iused Mounted on /dev/hd4 5.00 4.67 7% 2270 1% //dev/hd2 2.00 0.73 64% 30378 6% /usr/dev/hd9var 2.00 1.92 4% 435 1% /var/dev/hd3 2.00 1.83 9% 80 1% /tmp/dev/hd1 2.00 1.94 4% 18 1% /home/proc - - - - - /proc/dev/hd10opt 0.06 0.03 53% 756 5% /opt/dev/lv00 6.00 5.81 4% 17 1% /zxg10/dev/lv01 6.00 5.81 4% 17 1% /oracle/dev/lv02 0.06 0.06 4% 18 1% /var/adm/csd 利用率都不得超过85%,否则清理垃圾文件或扩文件系统注意:文件系统只能扩大,不能减小,操作请千万谨慎!7,系统内存限制#ulimit –a查看系统内存限制,修改/etc/security/limits文件,将内存限制放开,主要将data、stack、rss的值置为-1,其它项(如cpu等)根据需要也可置为-1,具体含义参看limits文件的注释说明。
AIX7.1安装EMCODM和PowerPath
AIX 7.1 安装 EMC ODM 和 PowerPath1.安装ODM解压缩# cd /tmp/emcsoft/odm# uncomp ress EMC.AIX.6.0.0.5.tar.Z # tar xvf EMC.AIX.6.0.0.5.tar安装ODM# smit in stallirscall ind upcUie soE 打cMove curjor TO d#s1red iten and pr«ss ent#r.update Tn^aTTMto LAT«sr(Update All J software Euixlietpdate software by Fix (APAB ) install And Lpdflt« froa ALLSoftwar*In stall Software -> En terTnit fll1 5ofTyptf ord vdluif for the ef^cry field.Press Enter AFTER vohirpg al 1 desired changes.II* INPUT device / directory for Software [ ./ ] -> EnterI Entry FlelilsJEsc + 7选择“ EMC Symmetrix AIX Support Software "和 “ EMC Symmetrix FCP Support Software ” -> En terinsiAi 1 MTiwjfeType or select valuer in entry Melds, Press Linicr A FTL K making all desired chinges .* 焉聲J 麒豁豐严 c r or ¥ tor software PEI^lElM OfTty? 1 operation wnll hOT Otcur)COMMfr 5ofti»are updates^ SAVE replaced f-i les?ALTTUF-^TicALLr 1ns 匚Nil requisite software? EX —E\D f T T B syitems i f sp ace reeded?OVERnRITE sarttf g ne»rtr versiOTkS? vLftiFV Irifiiall and check fUc s ■(工《? mclu<Je cor rEsponchnq LAPKUAGE fllcseii? bE-ATLED cut put?Proc«i i™ iT -iplie volume,, A£t 匚f>T new lIccREC agrfiCRicRx£?PREVIEW n«w LicE'JSEQentry Fields] rian_lAC CSC] rtonanoJPAR HanogenentPer form operation in dotal Envlironnerrt perform op ei ation or Dtia 匚hed rfPARS [WTacn^d hPAft hatiHS Rcnourt installation Device In vyPAHt Alte rnate W P4B install on oe\M ceyes noL_all_wparsJ* SOFTWARE to In stall -> F4SCFTWAR 匚 TO installMove cursor to desired item and press ESC -I -7. use arrow keys to scroll . ONE OR. MORE iienis can be selected.Enter AFTERP 广 e5Srtiaking al 1 selections.ALL+++++++++++B++++oooooooocco Qo ooooooo 0O o o o EMC EMC EMC EMC EMC EMCEW 匚 EW 匚 Erie EW 匚EMC EMC EMCFl=HeIpE5c+7=Select £nier=DoF2=Refre5hEsc+6=lrnage >Fl ndFSnzancel E5C+0=E3tiL n=Fl nd NexcARE YOU EURE?Continuing may del ete i n-Formati on you may want to keep- Thi 5 is your last chance to 5top before continuing.Press Enter to continue.Press Cancel Lo ret urn ro the app1i cation.En terCOmnand: JE sCdouT : ye5 stdGrr : no Rpftjrp ronrand ronplftlfin, fiddiTiorwl Instrurlrion'; nay nppesr bfI OM .T ;EKX. Syiwietrix flix. rt#SywieTriKnf CP ,rtepre-Instil lai ion ver1f icatioiK . xverifying selections*done verlTyinq requ+mlpes*< - done Resu Its,..listed In This setti 卯 p&ssed pre-install a 匸 i an verification b4 ■foEtili&d.« Fnri of Suff5frrifln >?Esc + 0查看安装的ODM 和版本Type or seltct values in enc ry fields, pr-flis truer AFTER making ill dcsizd changwh ■* TNPLrr device 「directory for serft 的r* 匸 50FTifeAHE to installpkkvZtw only? (Install operation will kOi occur) foCiMjirfiupdAlWi?5AVF rep lacF-d flips? AUTOMATICALLY 1 nil a h 「芒qd,"仇 io+rware'? EJCTQND flic s/3tc™; if 5pace needta^ QvER^凰JTE sme or newer ver510*5= VERIFY I ns Lili jrid check flit sizes?TiK.lude tnr Hi ponding LANGUAGf f ilestt s"^ OFTdlLFD (Hit pur Pr 匹nm ]11 pl 空 /gj 二_ _ _ _ PRtVibur fttw LlCE^Sb 暫《砂吟? [Entry F ieldsl no y«± no㈣yci no no yts no yes膺nohiPtR iMaragerentPerform OperMion in Global Environment Perform Operatlon on DeTacheri tPAfts IHiLdLUbdWPAK. h&i 血RfifOhnt Tn3tji1lAt ion O PVTC € in hP 九Alfpi-natp i<PAR InstallnfiaTi Devi CPyesng[_in严ACCEPT new lice nse agreeme nts?-> yes -> En terCOP<MAIUD STATUSIllFr=He 1pE5C+8=ImageF2=ftefre5-h E5t 十O=Exi t F3=cancel Enter=Do、TS11 -T ■> -cgiNQqwXY -1"-d-f Flip Z?A1files Gcs and win selected 1住ets5ym'='>Tis. aix. rte 5EJMC . SyniGtr 1 x. fcp. rte &.0.0. i* FVf ^yi^rpTrix AIX 5up[Kirt 5□-.. 4 tv (. ^ynretrlx rCP Support £□...P ilb ;:* INPUT device / directory for Software [ ./ ] -> Enter# Isl pp -L |gre p EMC2.安装 PowerPath解压缩# cd /tmp/e mcsoft/ pp# gun zip EMCPower.AIX60.SP1.GA.b132.tar.gz # tar xvf EMCPower.AIX.6.0.SP1.GA.b132.tar安装 PowerPath# smit in stallHtH'E cursor TO desired icen and press tmer,iJpdii i^Ljn sMiwjTE iti LdtML LuvdAll)Install sgfTiftarf Bundle Update Software hy Fix (APAfi) Erutil] Frcwi ALL 1 Ablk twjrvIn stall Software -> En terlypt or 主乜Tti" d valdt fur the crtLry ffeTtk Press Fnlpr AFTFR m 戒 ing all rfpii 厂*fi changes.EMC. symmetfix.a.ix. rte EMC. 5ymmet r i x.f cp,rte6.0,0.5 6,0. 0, 5EMC E 忖匚symmetrix symmexr-ix Aix support FCP SupporxInstall AndTnitall SoftwJtrpARE YOU SURE?En terlype or select walues Im entry fields.目「聲E tnC4r AFTER vjtk1 广勺 ill 曲£ 1 2d ChA0q4S.* liHP'UT d ev1 cc / directory for sGfxwarc * SOPTUfflHE tCh 1rSL JllPftevHE* only? (dnstail fipemrftrt wi ) 1 HOT occur) COMMIT softt^arc u palaces? SAvt replaced files?□^^unCMftTlCALLY install r €qu -i si t E ioftHare?EXTEND frit lyjtenoj if 3fmce ne«Jed^ QVfRhffirTE 5Me or ncAcr vfirsion 訐VERIFY 1 ns Lili and ch et(( file sizfis?include Lurrti^puiiding LAhHkJ^E fil-ietsr nFTATLFn QUTpytr Process nu1t~l 口die volumes 孑 PPFVTFk nPW LTCFVISF jgrpwnpntj^LGm ry FleldsltaP'AW tiaragenertp srf&r inn opura 匚Ion Im cl obi 1 tnv1rorti»i'it A----- 亠」—an Detached *PABsDerachert WPAB ftcrcunr installaclon Device InVI P AAS Alt«i WPAR jnn jllidon 曲vicePerform iQperatiQn oeTack - noL_al l-wp-srsj* SOFTWARE to In stall #保持默认“ all latest ”ACCEPT new lice nse agreeme nts?-> yes -> EnterConti nuirig may del ete i n^ormation you may want to keep. This is your last chance t□ stop before cont -inuTng.Press Enter to continue.P ress Cancel to ret urri to the appI i cafi on. F B HG 1 p E5C+8=ImageIllF2=ftefresh ESt 十0=Exi rF3=cancel Enter=Docomnanc: 32 stdout: yesstderr = rraEsc + 0查看安装的PowerPath 和版本# Isl pp -L |gre p EMC安装 Power path Lice nse# emc preg -add XXXX-XXXX-XXXX-XXXX-XXXX-XXXX扫描磁盘和配置PowerPath# cfgmgr -v # po wermt config查看PowerPath 磁盘信息nefore cotimflnd coinplotion, fldriiTionsl initruction 、 nsy Appear b 已 1M -'TOP ] l^mnstall -I "a =cg«QqH<v -z -<)./ "f Flic 1Fl le: I : SzTOCptiRf . b&ib t ; EMC power . MiQrntcoinpor**n (tI :£MCpo*er, nlgratloruenablflr T : EMC pcHher . rip:ce.0.1.06* O H 1/0 6.0.1.0 Pr fl-lnstal latlon \ier1f1 cat lion... v^rlfyinq eciIons.doneVeri fy"" ng r equi a 11 ea^ , _ done Results.-. £ll<-CF£5FS and hill 1 i ited 111 th \ 5 svC.t 1 Dtl p E±sa«cl p T (■- \ riit all Jt 1 on be in 巩!iHud"Selected F1 les Efts FMC ,V gfTtr mrufi nrprt fi,0.1.0 EMCpo*^ier. baseB.0.1. DEMCp owet". ml g r at i olT_tifiab 1 er £.0.1.0 EMC potver. up X 6. 0.1.0Privif rPflTh P oviQ rP at 11PowerPath Pm^erPath MijTti_P4thing MftrwgpTprt coTpon*^.,- BasEDriver ind ut ... Mfdrat iofl Enabler■ 11 Dite …EMc' symmetri x'. aix, rte 6.0.0. 5EMCEy ________________symmetrix symmetrix Aix support FCP support 0.0.1.0cFPowerPdl I WUIT1 _p^irmng# po wermt dis playsymmetr-ix 1 ogical device coijnt=32:KK ■ HK ■ ■;BnKn; ■ ■■■ ■ ■ ■ ■ — ■ ■■■■■■----- Host BUS Adapters ------------------- ------ i/o Paths ■ ■ ■■ ■ ------ stats### HW Pathsummary TotalDead I0i/S€C Q -IOSErrors0 fscsiO op final 64 o- 0 0 1 fsC512opt! rial64- 0# I查看详细的聚合设备和子设备信息# po wermt dis play dev=allPseudo name-hdiskpower31symmetrix 10-000^96800554 Logical device ID=00053Device bWN=6000097000049e600354533030303533 stai:e=al-ive : pol 1 cy=symnt)pr : queued-los=0保存配置# po wermt saveHw Path I/O parhsinterf . ModeStare Q-IOS Errors 1 f scsi2 hdiskl32 FA 2d :O5 active al ive 0 0 1 fscs^i2 hdisklO<]FA ld :05 active al ive 0 0 0 fscsiO hdisk&eFA 2d : 04 active alive0 0 0 f scsiOhdisk^eFAId : 04activeall iveStarsHOSTsror --- I/O Path --。
在AIX系统下安装EMC存储厂家的powerpath软件步骤
1 fscsi1 hdisk10 SP A1 active alive 0 0
smitty installp
如果没有 HA 环境(CLARIION),则选择以下两个软件包
EMC.CLARiiON.aix.rte
EMC.CLARiiON.fcp.rte
3、安装powerpath
installp -aXgd . EMCpower
检查powerpath 是否安装
lslpp -L EMC*
1 fscsi1 hdisk8 SP B0 active alive 0 0
Pseudo name=hdiskpower0
CLARiiON ID=FCNCX094800137 [44P270]
Logical device ID=60060160BCD22600D40C77408A88DF11 [44P270]
0 fscsi0 hdisk5 SP A0 active alive 0 0
1 fscsi1 hdisk7 SP B0 active alive 0 0
正常之后看到的应该如下内容:
# powermt display dev=all
Pseudo name=hdiskpower1
CLARiiON ID=FCNCX094800137 [44P270]
Logical device ID=60060160BCD2260066BEED26A392DF11 [REPORT]
state=alive; policy=CLAROpt; priority=0; queued-IOs=0
AIX 连接 EMC方法
安装顺序:●EMC.AIX.5.3.0.1.tar.Z●NA VIAGNT.lpp●NA VICLI.lpp●EMCPower.AIX.5.1.0.tar.gz先装驱动,后插卡lslpp –l | grep 软件名确保系统已经安装如下软件:bos.mppat.links(若这个包不装,装EMC ODM会出问题)mon.IBM.fc.rte/hba-api(通用驱动)devices.fcp.disk.array.rte(识别光纤通道硬盘必备)devices.pci.df1000f7.rte(HBA驱动)devices.pci.df1000f9.rte(HBA驱动)EMC需要的CLArrayS3.5.1.0.6 (只有这个软件是不在IBM光盘上,它放在EMC Utility CD 里面,解开一个压缩包,里面有这个文件),AIX5.3需要安装ODM。
ODM补丁打完必须要有:EMC.CLARiiON AIX Support SoftwareEMC.CLARiiON.fcp.rte (MPIO的补丁不要装)如果是两台AIX做HA,还要在HACMP软件包安装完以后HACMP配置之前在每台服务器上选择安装:EMC CLARiiON HA Concurrent Support正确的设置ODM HACMPdisktype命令如下:/usr/sbin/cluster/utilities/clcustomdisk -c -tdisk/pseudo/power -Ndisk/pseudo/power -gSCSI3 -hSCSI_TUR -b/usr/lpp/EMC/CLARiiON/bin/emcpowerreset -ptrue -mMKDEV注意这个命令要一次输完不要换行。
执行:#odmget HACMPdisktype 查看硬盘类型,例如:odmget HACMPdisktypeHACMPdisktype:PdDvLn = "disk/pseudo/power"ghostdisks = "SCSI3"checkres = "SCSI_TUR"breakres = "/usr/lpp/EMC/CLARiiON/bin/emcpowerreset"parallel = "true"makedev = "MKDEV"reserved1 = ""reserved2 = ""reserved3 = ""上述操作完成以后HACMP的custom disk磁盘资源会自动添加该HACMPdisk,HACMP软件包卸载后重新安装,要重新添加ODM。
emc存储操作手册
emc存储操作手册EMC存储操作手册EMC存储是一种用于数据存储和管理的先进技术。
本篇文章将为您提供一份简明的EMC存储操作手册,旨在帮助您了解EMC存储系统的基本操作和使用技巧。
请按照以下内容进行操作。
第一步:EMC存储的基本介绍EMC存储是一种高性能、高可用性的存储设备,广泛应用于企业级数据中心。
它具有可扩展性强、可靠性高、易于管理等优点。
在使用EMC存储之前,我们需要了解一些基本概念。
1. 存储池存储池是EMC存储系统中的一种逻辑存储单元,它由多个磁盘组成。
在创建存储池时,需要选择适当的存储级别和RAID级别以满足数据的安全性和性能需求。
2. 存储组存储组是一组关联的存储池。
在创建存储组时,我们可以选择将不同的硬盘池合并到同一个存储组中,以提高存储资源的利用率。
3. LUN(逻辑单元)LUN是EMC存储中一段逻辑空间,可以被主机应用程序访问。
在创建LUN时,我们可以选择容量大小、数据保护级别等。
第二步:EMC存储的基本操作在了解了基本概念之后,我们可以开始进行EMC存储的基本操作。
以下是一些常用操作:1. 创建存储池首先,登录EMC存储管理界面,选择“存储池管理”选项。
然后,点击“创建存储池”按钮,在弹出的对话框中填写相关信息,如存储级别、RAID级别等。
最后,点击“确定”按钮完成存储池的创建。
2. 创建存储组在存储池创建完成后,我们可以继续创建存储组。
选择“存储组管理”选项,点击“创建存储组”按钮,在弹出的对话框中选择相关存储池,并填写其他必要信息。
完成后,点击“确定”按钮。
3. 创建LUN通过上述步骤创建完存储组后,我们可以创建LUN。
选择“LUN管理”选项,点击“创建LU N”按钮,在弹出的对话框中选择存储组,并填写其他必要信息,如容量大小、数据保护级别等。
最后,点击“确定”按钮。
第三步:EMC存储的高级操作除了基本操作之外,EMC存储还提供了一些高级功能,以满足更复杂的存储需求。
1. 快照EMC存储支持快照功能,可以实现对LUN或文件系统的快速备份与恢复。
AIX连接EMC存储
二、Navisphere host agent安装
1.FTP Navisphere host agent
下载Navisphere host agent并至AIX主机
2.安装Navisphere host agent
安装NAVIAGENT
# installp -agXd . NAVIAGENT
x README.5303, 36133 bytes, 71 tape blocks
x EMC.AIX.5.3.0.3, 51814400 bytes, 101200 tape blocks
3.安装powerpath
#installp –agXd . EMCpower
+-----------------------------------------------------------------------------+
Pre-installation Verification...
+-----------------------------------------------------------------------------+
Verifying selections...done
5.启用PowerPath负载均衡
#powermt set policy=co dev=all
6.初始化powerpath hdiskpower设备
#powermt config
#
7.检查EMC链路状态
#powermt display dev=all
如果输出中所有的path都是“alive”则正常;否则,需要检查线缆及ZONE划分是否正确。
EMC磁盘连接AIX的方法及多路径冗余软件POWERPATH安装、配置、测试报告
EMC磁盘连接AIX的方法及多路径冗余软件POWERPATH安装、配置、测试报告第一、ODM部分 (2)1. 安装前准备工作 (2)获取EMC ODM文件 (2)2. 安装配置过程 (2)3、安装后确认 (3)第二、POWERPATH部分 (4)准备工作 (4)安装配置过程 (4)性能测试工作 (5)4、powermt提供的其他功能 (24)5、测试环境拓扑图 (26)第三、Appendix: (28)第一、ODM部分1. 安装前准备工作说明:一般情况下,AIX自带的FC驱动也可以让AIX正常识别出EMC的磁盘,但是会显示为other FC disk之类,这样powerpath是无法管理的,所以要加装ODM。
获取EMC ODM文件1、下载EMC odm文件,这是针对emc在aix提供的驱动。
下载地址:2. 安装配置过程1、下载的文件类型这个名字:EMC.AIX.5.3.0.1.tar.Z,通过FTP传到AIX上。
使用binary的方式传,否则无法解压。
2、gzip –d,tar xvf命令接包。
3、解包之后用installp命令。
4、安装的时候重点先看看包里面的readme文件,里面重点提到的是不管链接那种EMC设备都只能安装一种support软件,对于symmetric而言,只能安装如下3种文件的任意1种。
EMC Symmetrix FCP Support Software; IBM Fibre Channel driver support.EMC Symmetrix FCP MPIO Support Software; IBM default PCM MPIO support.EMC Symmetrix FCP PowerMPIO Support Software; PowerPath custom PCM MPIO support.(这次测试大部分时间都耗在这个问题上,以前没有认真看readme,把全部的都全部安装了。
AIX卷组下文件系统在线扩容
一台AIX小机因生产需要对/sapdata目录进行扩容,由原来的90G扩容到210G,增加120G 的空间.AIX小机后端通过光纤交换机连的EMC存储。
首先在EMC存储上把空闲的硬盘做RAID,划分LUN,映射到生产AIX小机。
EMC划完LUN映射完后,在AIX小机上执行cfgmgr ,然后lspv看是否认到新扩容的硬盘. # cfgmgr -i disk# lspvhdisk0 00c6abdfc094f4e8 rootvg activehdisk1 00c6abcfc4edbd87 rootvg activehdisk6 oravg activehdisk7 oravg active注意HDISK后的16位数字,如果没有请执行#chdev –l hdisk6 –a pv=yes (以使物理卷为LVM所用)。
#chdev –l hdisk7 –a pv=yes (以使物理卷为LVM所用)。
#lspvhdisk0 00c6abdfc094f4e8 rootvg activehdisk1 00c6abcfc4edbd87 rootvg activehdisk6 00c6abcf1d17f7bf oravg activehdisk7 00c6abcf1d189c64 oravg active(如果是HA架构,在A节点上识别到后执行#rmdev –Rd1 hdisk6然后在B节点上cfgmgr扫再认)--检查两节点LSPV是否一致和HDISK是否一致。
原文件目录大小#df -g/dev/sapdata 90.00 84.80 94% 26 1% /oracle/sapdata然后执行smitty hacmp--- System Management (C-SPOC)-- HACMP Logical Volume Management--- Shared Volume Groups-- Set Characteristics of a Shared Volume Group-- Add a Volume to a Shared Volume Group--选择需要扩容的VG--回车,然后选择添加的硬盘---确定。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
EMCpower.migration_enabler 5.3.0.0 USR APPLY SUCCESS
cluster.es.server.rte
cluster.base.server.rte
4.启用HBA卡快速接管功能
Enable the adapter driver fast_fail feature for each adapter to be managed by PowerPath:
# ps -ef |grep navi
root 119028 1 0 21:41:42 - 0:00 /usr/bin/naviagent -f /etc/Navisphere/agent.config
root 106774 126982 0 21:41:47 pts/0 0:00 grep navi
Key successfully installed.
Key (Enter if done):
1 key(s) successfully registered.
输入许可证回车即可。
Note: If you are upgrading from an earlier version of PowerPath, you do not need to reregister. PowerPath will use your old key.
用powermt display dev=hdiskpower0会看到这个hdiskpower0对应的hdiskX
Selected Filesets
-----------------
EMCpower.base 5.3.0.0 # PowerPath Base Driver and Ut...
EMCpower.consistency_grp 5.3.0.0 # PowerPath Consistency Group ...
#
注意:检查进程是否已经启动,如果没有进程起来,那么表示该版本agent不符合(即使安装和rc.agent命令运行成功),需要更换版本。
三、安装和配置PowerPath for AIX
注意事项
Do not attempt to run powermt config while using installp or SMIT to add, remove, or update PowerPath software. Doing so can result in a system crash.
Verifying requisites...done
Results...
SUCCESSES
---------
Filesets listed in this section passed pre-installation verification
and will be installed.
4.注册PowerPath
# emcpreg -install
=========== EMC PowerPath Registration ===========
Do you have a new registration key or keys to enter?[n] y
Enter the registration keys(s) for your product(s),
3.启动Navisphere Agent
# /etc/rc.agent stop
Navisphere Agent is not running
# /etc/rc.agent start
Starting Navisphere Agent
#
4.检查Navisphere Agent运行状态
二、Navisphere host agent安装
1.FTP Navisphere host agent
下载Navisphere host agent并至AIX主机
2.安装Navisphere host agent
安装NAVIAGENT
# installp -agXd . NAVIAGENT
EMCpower.encryption 5.3.0.0 USR APPLY SUCCESS
EMCpower.consistency_grp 5.3.0.0 USR APPLY SUCCESS
1.上传PowerPath for AIX
下载最新版本的PowerPath for AIX,并上传至AIX主机
2.解压PowerPath for AIX
# gunzip EMCPower.AIX.5.3.0.GA.tar.gz
# tar -xvf EMC.AIX.5.3.0.3.tar
EMC CLARiiON FCP Support Software
EMC CLARiiON HA Concurrent Support
注意:EMC CLARiiON HA Concurrent Support需要先安装HACMP,因为EMC CLARiiON HA Concurrent Support依赖以下filesets才能安装
one per line, pressing Enll keys, press Enter again.
Key (Enter if done): BYPK-6B4U-MFCE-QAW4-MP97-M9Y6
1 key(s) successfully added.
chdev -l fscsix -a fc_err_recov=fast_fail -P
where x is the specific HBA (fscsi0, fscsi1, and so forth).
5.重启主机
注意:安装ODM之后,主机需要重启才能生效
#shutdown –Fr
-------------------------------------------------------------------------------
EMCpower.base 5.3.0.0 USR APPLY SUCCESS
x README.5303, 36133 bytes, 71 tape blocks
x EMC.AIX.5.3.0.3, 51814400 bytes, 101200 tape blocks
3.安装powerpath
#installp –agXd . EMCpower
+-----------------------------------------------------------------------------+
一、AIX ODM包安装
1.下载ODM包软件
ftp:///pub/elab/aix/ODM_DEFINITIONS
2.解压ODM
上传至AIX主机后,用uncompress和tar解压
# uncompress EMC.AIX.5.3.0.3.tar.Z
# tar -xvf EMC.AIX.5.3.0.3.tar
Pre-installation Verification...
+-----------------------------------------------------------------------------+
Verifying selections...done
EMCpower.encryption 5.3.0.0 # PowerPath Encryption with RSA
EMCpower.migration_enabler 5.3.0.0 # PowerPath Migration Enabler ...
x README.5303, 36133 bytes, 71 tape blocks
x EMC.AIX.5.3.0.3, 51814400 bytes, 101200 tape blocks
3.安装ODM
#smitty installp
选择以下进行安装
EMC CLARiiON AIX Support Software
EMCpower.mpx 5.3.0.0 # PowerPath Multi_Pathing Exte...
>
Installation Summary
--------------------
Name Level Part Event Result
5.启用PowerPath负载均衡
#powermt set policy=co dev=all
6.初始化powerpath hdiskpower设备
#powermt config
#
7.检查EMC链路状态
#powermt display dev=all
如果输出中所有的path都是“alive”则正常;否则,需要检查线缆及ZONE划分是否正确。