Cutler-Hammer PONI通信模块商品说明说明书
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
TD02603007E
For more information visit:
New Information
Description
Page
Power Management Systems PONI Communication Modules
General Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 PONI Communication Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Metered Parameters/Communications. . . . . . . . . . . . . . . . . . . . . . . . . . 2 Physical Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Certifications/Listings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Communications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 IPONI. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 BPONI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 EPONI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 MPONI. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Selection Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5 Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6 Ordering Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6
Technical Data
Page 2Effective: June 2003Power Management Systems PONI Communication Modules
General Description
The Product Operated Network Inter-face (PONI) cards add communications to various Eaton’s Cutler-Hammer products. With the addition of the PONI card, the Cutler-Hammer device can communicate with a master unit such as a MINT, a NetLink, a CONI card in a personal computer, or, in the case of the RS-485 PONI, a Modbusாmaster device. The PONIs can be easily mounted to the Cutler-Hammer device.
All PONIs, except the RS-485 PONI, enable communications and work together as part of a Cutler-Hammer PowerNetீ monitoring system. There are multiple communication levels possible throughout the PowerNet system. The BPONIs and IPONIs are daisy-chained together on the first level network, the INCOMீ network, and can be terminated at a NetLink,
a MINT II, or a CONI card in a personal computer.
The Ethernet PONIs attach a device directly to an Ethernet network.
An Ethernet network is often applied as the high-speed backbone network for larger facilities.
The RS-485 PONI is also applied in a daisy-chained configuration. However, the RS-485 PONI communicates the Modbus RTU protocol via an RS-485 network. The RS-485 PONI is a slave device connected to an RS-485 Mod-bus master. By using Modbus function codes, the RS-485 PONI can pass host product commands/data directly to the attached host product.
PONIs enable continuous remote communications of all metering parameters, protective settings and device status to a remote monitoring device. Each PONI uniquely identifies its associated device on the network with a unique three-digit hex address, IP address in the case of the Ethernet PONI, or a Modbus address with the RS-485 PONI. BPONIs, IPONIs and RS-485 PONIs include a terminal block for terminating the twisted shielded pair network cables. The Ethernet PONI has an RS-232 port for configuration and firmware upgrades along with an RJ45 Ethernet port.
PONI Communication Modules
Applications
The Product Operated Network
Interface (PONI) cards attach to
Cutler-Hammer devices to enable
communications.
Metered Parameters/
Communications
A PONI enables communication of the
metered parameters and setpoints
consistent with those of the device to
which it is attached.
Physical Characteristics
Each PONI attaches to its associated
product. The BPONI, IPONI and
RS-485 PONI obtain power from the
host product. The EPONI may be host
or separately powered depending on
the host.
Note: MP-3000 and IQ 1000 II application
may require a mounting bracket.
Certifications/Listings
IPONI
s ULா/CUL
EPONI
s UL/CUL(EN61010-1)
RS-485 PONI
s UL, CSAா, CE
s EN61000-6-2
s EN55011
Communications
The IPONI and BPONI enable commu-
nications over a twisted shielded pair
INCOM device network. The RS-485
PONI enables communication over a
Modbus RTU network. The Ethernet
PONI enables device communications
over a 10 megabaud Ethernet network.
For more information visit: TD02603007E
TD02603007E For more information visit:
Technical Data
Effective: June 2003
Page 3
Power Management Systems PONI Communication Modules
IPONI
The INCOM Product Operated Network Interface card, or IPONI card, adds communication capability to various Cutler-Hammer products. Each IPONI has three 16-digit address switches to uniquely identify each device on the network. IPONIs are designed to be daisy-chained throughout a unit sub-station or equipment room to a master device such as a NetLink, MINT II or a CONI in a master computer. From the NetLink or a master computer, information is distributed through the facility’s TCP/IP Ethernet network. A twisted shielded pair network
connecting IPONIs may extend up to 10,000 feet (3,048 m) before terminat-ing in a NetLink, computer, or another master device. The IPONI comes with mounting hardware and attaches to the back of its associated device.
BPONI
The Buffered Product Operated Net-work Interface card, or BPONI card, adds communication capability to various Cutler-Hammer products. It provides the same functionality as the IPONI but is recommended for different devices. Each BPONI has three 16-digit address switches to uniquely identify each device on the network. BPONIs are designed to be daisy-chained throughout a unit sub-station or equipment room to a master device such as a NetLink, MINT II or a CONI in a master computer. From the NetLink or a master computer, information is distributed through the facility’s TCP/IP Ethernet network. A twisted shielded pair network
connecting BPONIs may extend up to 8,500 feet (2,591 m) before terminating in a NetLink, computer, or another master device. The BPONI comes
with mounting hardware and attaches to the back of its associated device.
Note: The BPONI must be mounted on the load end of the IQ 500.
Figure 1. IPONI Wiring
Figure 2. BPONI Wiring
Note:
BPONIs and IPONIs may be daisy-chained together with other IMPACC/PowerNet devices on a common twisted shielded pair network.
Technical Data
Page 4Effective: June 2003Power Management Systems PONI Communication Modules
EPONI
The Ethernet Product Operated Network Interface card, or EPONI card, attaches directly to the back
of an IQ Analyzer, an IQ DP-4000ீ
or IQ Data Plus IIீ. It supports TCP/IP Ethernet communications at 10 megabauds. It has a 10Base-T (RJ45) interface. Contact the Cutler-Hammer business for EPONI compatibility
with other Cutler-Hammer products and availability.
RS-485 PONI
Modbus communication capability to
MPONI contains two rotary address switches to uniquely identify each
DIP switch. A 5-pin connector is pro-
Various baud rates are available for networking flexibility, and onboard LEDs indicate operation, error and communication status. The MPONI is
connected by a dedicated shielded
in a daisy-chain configuration to com-
device and may extend up to 4,000 feet (1,219 m) without a repeater. The MPONI comes with mounting hardware and attaches to the back
of its associated device.
Note: Please see IL for detailed register support information for each supported product. Not all device functionality is supported with the RS-485 PONI over
the Modbus Protocol.
Figure 3. EPONI Wiring
Figure 4. RS-485 PONI
For more information visit: TD02603007E
TD02603007E For more information visit:
Technical Data
Effective: June 2003
Page 5
Power Management Systems PONI Communication Modules
Selection Data
Table 1. PONI Selection Chart
Legend: q =Fully compatible.
³ =Compatible with greater than or equal to firmware version. £ =Compatible with less than or equal to firmware version.
IQ Device IPONI
BPONI
EPONI
MPONI
IQ Analyzer ³1.06 £1.05
q ³2.02IQ DP-4000q q ³ 1.04AEM q
CED q CMU q BIM q
IQ Transfer q
³ 4.5
IQ 1000 II q
MP-3000 q
³1.08
IQ 500q IQ Generator q
IQ Data q
IQ Data Plus II In Buff-mode
q
³8B 6/26/95ATC-400
³
1.40
Power Command Software Support Cutler-Hammer PowerNet q q q
IMPACC/PowerNet Series III q
q Universal RTD Module
In Buff-mode
Technical Data
Page 6Effective: June 2003Power Management Systems PONI Communication Modules
Specifications
IPONI
s Temperature
-20°C to 70°C
s Humidity
5% to 95% non-condensing
s Power
20 to 30 Vdc maximum, 50 mA
nominal, 100 mA maximum
s Speed
1200 and 9600 bauds
s Communications
Three-position removable terminal block for twisted shielded pair
INCOM
BPONI
s Temperature
-20°C to 70°C
s Humidity
5% to 95% non-condensing
s Power
20 to 30 Vdc maximum,
150 mA maximum
s Speed
1200 and 9600 bauds
s Communications
Two-position removable terminal block, twisted shielded pair INCOM
EPONI
s Temperature
-20°C to 70°C
s Humidity
5% to 95% non-condensing
s Power
20 to 30 Vdc maximum,
150 mA maximum
s Speed
10 megabauds
s Communications
10Base-T (RJ45) AUI port
MPONI
s Temperature
-20°C to 60°C
s Humidity
5% to 95% non-condensing
s Power
24 Vdc maximum, 50 mA
s Speed
1200, 9600 or 19,200 bauds
s Communications
Five-position removable terminal
block for twisted shielded pair Mod-
bus RTU (A, B, Common, Shield,
and Optional Chassis Ground)
Ordering Information
Table 2. PONI Communication Modules
UL is a federally registered trademark
of Underwriters Laboratories Inc.
CSA is a registered trademark of the
Canadian Standards Association.
Modbus is a registered trademark of
Modicon, a division of Schneider
Electric Industries SA.
Description Catalog
Number
INCOM PONI IPONI
Buffered PONI BPONI
Ethernet PONI EPONI
RS-485 PONI MPONI
For more information visit: TD02603007E
TD02603007E For more information visit:
Technical Data
Effective: June 2003
Page 7
Power Management Systems PONI Communication Modules
This page intentionally left blank.
Technical Data
Page 8Effective: June 2003Power Management Systems
PONI Communication
Modules
© 2003 Eaton Corporation
All Rights Reserved
Printed in USA
Publication No. TD02603007E
June 2003
Eaton Corporation
Cutler-Hammer business unit 1000 Cherrington Parkway Moon Township, PA 15108-4312 USA
tel: 1-800-525-2000。