Data sheet
6ES7313-6CG04-0AB0
SIMATIC S7-300, CPU 313C-2DP COMPACT CPU WITH MPI, 16 DI/16 DO, 3 FAST COUNTERS (30 KHZ), INTEGRATED DP INTERFACE, INTEGRATED 24V DC POWER SUPPLY, 128 KBYTE WORKING MEMORY, FRONT CONNECTOR (1 X 40PIN) AND MICRO MEMORY CARD REQUIRED
CPU processing times for bit operations, typ. for word operations, typ. for fixed point arithmetic, typ. for floating point arithmetic, typ.
CPU-blocks Number of blocks (total)
16 4
256
Yes 0 255 Z 0 to Z 7
0 999
Yes SFB Unlimited (limited only by RAM capacity)
256
Yes 0
03.08.2015
Changes preserved © Copyright Siemens AG
— upper limit — preset Time range — lower limit — upper limit IEC timer ● present ● Type ● Number
1 024; Number range: 1 to 16000 64 kbyte Yes; via non-retain property on DB Yes
32 kbyte; Max. 2048 bytes per block
2 048 byte 2 048 byte
2 030 byte 2 030 byte
2 048 byteຫໍສະໝຸດ 2 048 byte 2 048 byte 2 048 byte 128 byte 128 byte
124.0 to 125.7 124.0 to 125.7
6ES7313-6CG04-0AB0 Page 4/13
03.08.2015
Changes preserved © Copyright Siemens AG
3
1 4
8 8 6
4 8; In rack 3 max. 7
Time of day Clock ● Hardware clock (real-time clock) ● retentive and synchronizable ● Backup time ● Deviation per day, max. ● Behavior of the clock following POWER-ON ● Behavior of the clock following expiry of backup period Operating hours counter ● Number ● Number/Number range ● Range of values ● Granularity ● retentive Clock synchronization ● supported ● to MPI, master ● to MPI, slave ● to DP, master
0.07 µs 0.15 µs 0.2 µs 0.72 µs
1 024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used. 1 024; Number range: 1 to 16000 64 kbyte
6ES7313-6CG04-0AB0 Page 3/13
1 024; Number range: 0 to 7999 64 kbyte
1 024; Number range: 0 to 7999 64 kbyte
see instruction list 64 kbyte 1; OB 1 1; OB 10 2; OB 20, 21 4; OB 32, 33, 34, 35 1; OB 40 3; OB 55, 56, 57 1; OB 100 5; OB 80, 82, 85, 86, 87 2; OB 121, 122
Input current Current consumption (rated value) Current consumption (in no-load operation), typ. Inrush current, typ. I²t Digital inputs ● from load voltage L+ (without load), max. Digital outputs ● from load voltage L+, max.
255 No retentivity
10 ms 9 990 s
Yes SFB Unlimited (limited only by RAM capacity)
All, max. 64 KB
256 byte Yes; MB 0 to MB 255 MB 0 to MB 15 8; 1 memory byte
1 015 248 1 015 248
Hardware configuration Number of expansion units, max. Number of DP masters ● integrated ● via CP Number of operable FMs and CPs (recommended) ● FM ● CP, point-to-point ● CP, LAN Rack ● Racks, max. ● Modules per rack, max.
DB ● Number, max. ● Size, max.
Yes
24 V No
800 mA 110 mA 5A 0.7 A²·s 80 mA
50 mA
9W
128 kbyte No 64 kbyte
Yes 8 Mbyte 10 y
Yes; Guaranteed by MMC (maintenance-free) Yes; Program and data
Nesting depth ● per priority class ● additional within an error OB
Counters, timers and their retentivity S7 counter ● Number Retentivity — adjustable — lower limit — upper limit — preset Counting range — lower limit — upper limit IEC counter ● present ● Type ● Number S7 times ● Number Retentivity — can be set — lower limit
General information Hardware product version Firmware version Engineering with ● Programming package
Supply voltage Rated value (DC) ● 24 V DC permissible range, lower limit (DC) permissible range, upper limit (DC) external protection for power supply lines (recommendation) Mains buffering ● Mains/voltage failure stored energy time ● Repeat rate, min. Digital inputs Load voltage L+ — Rated value (DC)
Power loss Power loss, typ.
Memory Work memory ● Integrated ● expandable ● Size of retentive memory for retentive data blocks Load memory ● Plug-in (MMC) ● Plug-in (MMC), max. ● Data management on MMC (after last programming), min. Backup ● present ● without battery
6ES7313-6CG04-0AB0 Page 2/13
03.08.2015
Changes preserved © Copyright Siemens AG
FB ● Number, max. ● Size, max.
FC ● Number, max. ● Size, max.
OB ● Description ● Size, max. ● Number of free cycle OBs ● Number of time alarm OBs ● Number of delay alarm OBs ● Number of cyclic interrupt OBs ● Number of process alarm OBs ● Number of DPV1 alarm OBs ● Number of startup OBs ● Number of asynchronous error OBs ● Number of synchronous error OBs
Address area I/O address area ● Inputs ● Outputs of which distributed — Inputs — Outputs Process image ● Inputs ● Outputs ● Inputs, adjustable ● Outputs, adjustable ● Inputs, default ● Outputs, default Default addresses of the integrated channels — Digital inputs — Digital outputs Digital channels
5 ms 1s
24 V 03.08.2015
Changes preserved © Copyright Siemens AG
— Reverse polarity protection Digital outputs
Load voltage L+ — Rated value (DC) — Reverse polarity protection
6ES7313-6CG04-0AB0 Page 1/13
01 V3.3
STEP 7 V5.5 + SP1 or higher or STEP 7 V5.3 + SP2 or higher with HSP 203
Yes 19.2 V 28.8 V Miniature circuit breaker, type C; min. 2 A; miniature circuit breaker type B, min. 4 A
Data areas and their retentivity retentive data area in total Flag ● Number, max. ● Retentivity available ● Retentivity preset ● Number of clock memories Data blocks ● Number, max. ● Size, max. ● Retentivity adjustable ● Retentivity preset Local data ● per priority class, max.
● Inputs — of which central
● Outputs — of which central
Analog channels ● Inputs — of which central ● Outputs — of which central
16 256 1 008 16 256 1 008