储血冰箱空气培养不合格处理流程
1.当储血冰箱空气培养结果不合格时,首先将通知相关人员并立
即停止使用该储血冰箱。
When the air culture of the blood storage refrigerator is found to be unqualified, the relevant personnel should be notified immediately and the use of the refrigerator should
be stopped.
2.隔离不合格的储血冰箱,并标记清楚以防止误用。
Isolate the unqualified blood storage refrigerator and label it clearly to prevent misuse.
3.将冰箱内的血液制品转移至其他符合要求的储存设备中。
Transfer the blood products in the refrigerator to other storage devices that meet the requirements.
4.清洁并消毒不合格的储血冰箱,确保彻底清除可能存在的污染。
Clean and disinfect the unqualified blood storage refrigerator to thoroughly remove any potential contamination.
5.根据相关规定,对储血冰箱进行维修或更换,直到通过再次培
养确认其合格。
According to the relevant regulations, repair or replace the blood storage refrigerator until it is confirmed to be qualified through re-culture.
6.汇报整个处理流程和处理结果,并根据需要整改相关操作规程
和管理制度。
Report the entire process of handling and the results,
and revise the relevant operating procedures and management systems as needed.
7.维持储血冰箱的清洁和消毒,定期进行空气培养和生物负荷监测,确保贮存环境符合要求。
Maintain the cleanliness and disinfection of the blood storage refrigerator, and conduct regular air culture and
bioburden monitoring to ensure that the storage environment meets the requirements.
8.继续加强人员的培训和管理,提高操作规范,以预防同类事件再次发生。
Continue to strengthen personnel training and management, improve operation standards to prevent similar incidents from happening again.。