CSR-2060说明书

合集下载

1SC2060P2Ax-17 Preliminary Datasheet说明书

1SC2060P2Ax-17 Preliminary Datasheet说明书

1SC2060P2Ax-17 Preliminary DatasheetSingle-Channel High-Power High-Frequency SCALE-2 Driver CoreAbstractThe 1SC2060P2Ax-17 is a 20W, 60A CONCEPT driver core. This high-performance SCALE-2 driver targets high-power single-channel IGBT and MOSFET applications such as induction heating, resonant and high-frequency power conversion as well as parallel gate driving of large modules.It features newly developed planar transformer technology for a real leap forward in power density, noise immunity, and reliability.Equipped with the latest SCALE-2 chipset, the gate driver supports switching up to 500kHz at best-in-class efficiency. The 1SC2060P2Ax-17 effectively comprises a complete single-channel IGBT driver core, fully equipped with an isolated DC/DC converter, short-circuit protection, advanced active clamping and supply-voltage monitoring.With its extremely compact outline of 44mm x 74mm and a total height of typ. 6.5mm, it delivers high power density with an attractive form factor. Thanks to the highly integrated SCALE-2 chipset, the component count is reduced by 80% compared to conventional solutions. This results in significantly increased reliability and reduced costs.Product Highlights Applications20W maximum output power Induction heatingSwitching up to 500kHz High-frequency convertersNew SCALE-2 platform High-current switchesPlanar transformer Industrial drivesJitter less than ±1ns Pulse powerSignal delay < 80ns Resonant switching3.3V…15V input logic Wind power converters1700V isolation (signal + DC/DC) Single switch controlSafe isolation to EN 50178 Parallel connection of modulesUL compliantDedicated IGBT and MOSFET modePreliminary Data SheetSafety Notice!The data contained in this data sheet is intended exclusively for technically trained staff. Handling all high-voltage equipment involves risk to life. Strict compliance with the respective safety regulations is mandatory! Any handling of electronic devices is subject to the general specifications for protecting electrostatic-sensitive devices according to international standard IEC 60747-1, Chapter IX or European standard EN 100015 (i.e. the workplace, tools, etc. must comply with these standards). Otherwise, this product may be damaged. Important Product DocumentationThis data sheet contains only product-specific data. For a detailed description, must-read application notes and important information that apply to this product, please refer to “1SC2060P Description & Application Manual” on /go/1SC2060PAbsolute Maximum RatingsParameter Remarks Min Max Unit Supply voltage V DC VDC to GND 0 16 V Supply voltage V CC VCC to GND 0 16 V Logic input and output voltages Primary side, to GND -0.5 VCC+0.5 V SO current Failure condition, total current 20 mA Gate peak current I out Notes 1, 11 -60 +60 A Average supply current I DC Notes 2, 3 2100 mA Output power Ambient temperature <70°C (Notes 4, 5) 23 WAmbient temperature 85°C (Note 4) 21 W Switching frequency F 500 kHz Test voltage (50Hz/1min.) Primary to secondary side (Note 12) 5000 V AC(eff) Operating voltage Primary to secondary side 1700 V peak |dV/dt| Rate of change of input to output voltage (Note 17) 100 kV/μs Operating temperature Note 5 -40 +85 °C Storage temperature -40 +90 °C Recommended Operating ConditionsPower Supply Remarks Min Typ Max Unit Supply voltage V DC VDC to GND, IGBT mode 14.5 15 15.5 V Supply voltage V DC VDC to GND, MOSFET mode (Note 10) 6 12 V Supply voltage V CC VCC to GND 14.5 15 15.5 VPreliminary Data Sheet Electrical Characteristics (IGBT mode)All data refer to +25°C and V CC = V DC= 15V unless otherwise specified.Power supply Remarks Min Typ Max UnitSupply current I DC Without load 36 60 mA Supply current I CC F = 0Hz 12 15 mA Supply current I CC F = 360kHz 31 mA Coupling capacitance C io Primary to output, total 40 pF Power Supply Monitoring Remarks Min Typ Max UnitSupply threshold V CC Primary side, clear fault 11.9 12.6 13.3 VPrimary side, set fault (Note 18) 11.3 12.0 12.7 V Monitoring hysteresis Primary side, set/clear fault 0.35 V Supply threshold V ISO-V E Secondary side, clear fault 12.1 12.6 13.1 VSecondary side, set fault (Note 18) 11.5 12.0 12.5 V Monitoring hysteresis Secondary side, set/clear fault 0.35 V Supply threshold V E-V COM Secondary side, clear fault 5 5.15 5.3 VSecondary side, set fault (Note 18) 4.7 4.85 5 V Monitoring hysteresis Secondary side, set/clear fault 0.15 V Logic Inputs and Outputs Remarks Min Typ Max UnitInput bias current V(IN) > 3V 190 µA Turn-on threshold V(IN) 2.6 V Turn-off threshold V(IN) 1.3 V SO output voltage Failure condition, I(SO)<20mA 0.7 V Short-Circuit Protection Remarks Min Typ Max UnitCurrent through pin REF R(REF, VE)<70kΩ150 µA Minimum response time Note 15 1.2 µs Minimum blocking time Note 16 9 µs Timing Characteristics Remarks Min Typ Max UnitTurn-on delay t d(on)Note 6 75 ns Turn-off delay t d(off)Note 6 70 ns Jitter of turn-on delay Note 20 ±1 ns Jitter of turn-off delay Note 20 ±1 ns Output rise time t r(out)Note 7 10 ns Output fall time t f(out)Note 7 15 ns Transmission delay of fault state Note 19 400 nsPreliminary Data SheetElectrical Isolation Remarks Min Typ Max UnitTest voltage (50Hz/1s) Primary to secondary side (Note 12) 5000 5050 5100 V AC(eff) Partial discharge extinction volt. Note 13 1768 V peak Creepage distance Primary to secondary side 15 mm Clearance distance Primary to secondary side 15 mm Output Remarks Min Typ Max UnitBlocking capacitance VISO to VE Note 14 9.4 µF Blocking capacitance VE to COM Note 14 9.4 µFExternal gate resistor loop F≤ 250kHz(Note 8) 2.0 ΩTurn-on gate resistor R g(on)F≤ 250kHz (Note 9) 1.0 ΩTurn-off gate resistor R g(off)F≤ 250kHz (Note 9) 1.0 ΩExternal gate resistor loop F≤ 310kHz(Note 8) 3.2 ΩTurn-on gate resistor R g(on)F≤ 310kHz (Note 9) 1.6 ΩTurn-off gate resistor R g(off)F≤ 310kHz (Note 9) 1.6 ΩExternal gate resistor loop F≤ 360kHz(Note 8) 4.8 ΩTurn-on gate resistor R g(on)F≤ 360kHz (Note 9) 2.4 ΩTurn-off gate resistor R g(off)F≤ 360kHz (Note 9) 2.4 ΩOutput powerThe permissible drive power at the output of the driver card is given versus switching frequency for different total gate resistance values. Linear interpolation is permissible for gate resistance values other than those shown. However, no extrapolation beyond the given data range is allowed.Preliminary Data Sheet Fig. 1 Output power vs. switching frequency at ambient temperature range – 40°C through 85°CFig. 2 Output power vs. switching frequency at ambient temperature range – 40°C through 70°CPreliminary Data SheetTo check if the driver output power is in accordance with the data given in Figs. 1 and 2, proceed as follows: •determine the actual gate charge of the power switch•check with note 14•determine the output voltage swing of the driver at the required switching frequency•calculate the output power as gate charge x voltage swing x frequency•check the calculated power at the relevant switching frequency against the diagram “Output power vs.switching frequency” at the appropriate max. temperature (70°C / 85°C)The actual value of the driver’s output voltage swing should be taken to determine the output power drawn from the driver. If the nominal (no-load) value is taken, the driver will not be operated up to its full capacity. See the section “Output voltage swing” for output voltage swing vs. output power.Output voltage swingThe output voltage swing consists of two distinct segments. First, there is the turn-on voltage V GH between pins GH and VE. V GH is regulated and maintained at a constant level for all output power values and frequencies.The second segment of the output voltage swing is the turn-off voltage V GL. V GL is measured between pins GL and VE. It is a negative voltage. It changes with the output power to accommodate the inevitable voltage drop across the internal DC/DC converter.Output Voltage Remarks Min Typ Max Unit Turn-on voltage, V GH Any load condition 15.0 V Turn-off voltage, V GL No load -10.5 V Turn-off voltage, V GL1W output power -9.2 V Turn-off voltage, V GL20W output power -7.5 VFig. 3 Output voltage swing (typ.) vs. output powerPreliminary Data Sheet Electrical Characteristics (MOSFET Mode)All data refer to +25°C and V CC = 15V unless stated otherwise.Power supply Remarks Min Typ Max UnitSupply current I DC V DC=9.2V, without load 25 mA Supply current I CC F= 0Hz 12 mA Supply current I CC F= 500kHz 39 mA Coupling capacitance C io Primary to output, total 40 pF Power Supply Monitoring Remarks Min Typ Max UnitSupply threshold V CC Primary side, clear fault 11.9 12.6 13.3 VPrimary side, set fault (Note 18) 11.3 12.0 12.7 V Monitoring hysteresis Primary side, set/clear fault 0.35 V Supply threshold V ISO-V VE Secondary side, clear fault 8.3 8.75 9.2 VSecondary side, set fault (Note 18) 7.9 8.2 8.6 V Monitoring hysteresis Secondary side, set/clear fault 0.23 0.5 V Logic Inputs and Outputs Remarks Min Typ Max UnitInput bias current V(IN) > 3V 160 µA Turn-on threshold V(IN) 2.6 V Turn-off threshold V(IN) 1.3 V SO output voltage Failure condition, I(SO)<20mA 0.7 V Short-circuit Protection Remarks Min Typ Max UnitCurrent through pin REF R(REF, VE)<70kΩ150 µA Minimum response time Note 15 1.2 µs Minimum blocking time Note 16 9 µs Timing Characteristics Remarks Min Typ Max UnitTurn-on delay t d(on)Note 6 75 ns Turn-off delay t d(off)Note 6 70 ns Jitter of turn-on delay Note 20 ±1 ns Jitter of turn-off delay Note 20 ±1 ns Output rise time t r(out)Note 7 10 ns Output fall time t f(out)Note 7 15 ns Transmission delay of fault state Note 19 400 nsPreliminary Data SheetElectrical Isolation Remarks Min Typ Max UnitTest voltage (50Hz/1s) Primary to secondary side (Note 12) 5000 5050 5100 V AC(eff) Partial discharge extinction volt. Note 13 1768 V peak Creepage distance Primary to secondary side 15 mm Clearance distance Primary to secondary side 15 mm Output Remarks Min Typ Max UnitBlocking capacitance VISO to VE Note 14 9.4 µF Blocking capacitance VE to COM VE is short-circuited to COM Not applicable External gate resistor loop F≤ 500kHz(Note 8) 2.0 ΩTurn-on gate resistor R g(on)F≤ 500kHz (Note 9) 1.0 ΩTurn-off gate resistor R g(off)F≤ 500kHz (Note 9) 1.0 ΩOutput powerThe permissible drive power at the output of the driver card is given versus the switching frequency for an output voltage swing of 10V and 15V. No extrapolation is allowed beyond the given data range towards higher frequency values.Fig. 4 Output power vs. switching frequency for ambient temperature range – 40°C through 85°CTo check if the driver output power is in accordance with the data given in Fig. 4, proceed as follows: •determine the actual gate charge of the power switch•check with note 14•determine the output voltage swing of the driver at the required switching frequency•calculate the output power as gate charge x voltage swing x frequencyPreliminary Data Sheet •check the calculated power at the relevant switching frequency against the diagram “Output power vs.switching frequency” at the appropriate max. temperature (85°C)The actual value of the driver’s output voltage swing should be taken to determine the output power drawn from the driver. If the nominal (no-load) value is taken, the driver will not be operated up to its full capacity. See the section “Output voltage swing” for output voltage swing vs. output power.Output voltage swingThe output voltage swing in MOSFET mode directly follows the primary-side input voltage V DC. The following table gives exemplary input voltages V DC for a set of output voltages under various load conditions.V DC for V GH=10V Remarks Min Typ Max Unit Primary side input, V DC No load 6.3 V Primary side input, V DC12W output power 7.8 VV DC for V GH=15V Remarks Min Typ Max Unit Primary side input, V DC No load 9.2 V Primary side input, V DC17W output power 10.5 V Footnotes to the Key Data1)The maximum peak gate current refers to the highest current level occurring during the productlifetime. It is an absolute value and does also apply for short pulses.2)The average supply input current is limited for thermal reasons. Higher values than specified by theabsolute maximum rating are permissible (e.g. during power supply start up) if the average remains below the given value, provided the average is taken over a time period which is shorter than the thermal time constants of the driver in the application.3)There is no means of actively controlling or limiting the input current in the driver. In the case ofstart-up with very high blocking capacitor values, or in case of short circuit at the output, the supply input current has to be limited externally.4)The maximum output power must not be exceeded at any time during operation. The absolutemaximum rating must also be observed for time periods shorter than the thermal time constants of the driver in the application.5)An extended output power range is specified in the output power section for maximum ambienttemperatures of 70°C. In that case, the absolute maximum rating for the operating temperature changes to (–40°C - 70°C) and the absolute maximum output power rating changes to 23W.6)The delay time is measured between 50% of the input signal and 20% voltage swing of thecorresponding output. The delay time is independent of the output loading.7)Output rise and fall times are measured between 10% and 90% of the nominal output swing. Thevalues are given for the driver side of the gate resistors. The time constant of the output load in conjunction with the present gate resistors leads to an additional delay at the load side of the gate resistors.8)The external gate resistor loop comprises all resistors located between the driver gate and the driveremitter. The internal resistance of any output load (e.g. an IGBT module) makes no contribution.Example:Total turn-on gate resistance: 1.0ΩTotal turn-off gate resistance: 1.5ΩIGBT module internal gate resistance: 0.25ΩLeads to:Preliminary Data SheetExternal turn-on gate resistance: 0.75ΩExternal turn-off gate resistance: 1.25ΩExternal gate resistor loop: 2.0Ω9)The values given refer to the total gate resistance, including both external resistors and the internalresistance of the power module / transistor.10)The secondary side output voltage swing must not exceed 20V.11)The maximum current given is the short circuit value of the output stage. Continuous operation islimited by thermal constraints. The surface temperature of the output stage must not exceed 125°C. 12)HiPot testing (= dielectric testing) must generally be restricted to suitable components. This gatedriver is suited for HiPot testing. Nevertheless, it is strongly recommended to limit the testing time to 1s slots as stipulated by EN 50178. Excessive HiPot testing at voltages much higher than 1200V AC(eff) may lead to insulation degradation. No degradation has been observed over 1min. testing at 5000V AC(eff). Every production sample shipped to customers has undergone 100% testing at 5000V AC(eff) (typical) for 1s.13)Partial discharge measurement is performed in accordance with IEC 60270 and isolation coordinationspecified in EN 50178. The minimum value given is designed to include appropriate safety margins for long-term ageing. Accelerated ageing tests show virtually no insulation deterioration. Minimum partial discharge extinction voltages remain >2100V even after 2600 slow thermal cycles between –40°C and 125°C and also after 500 thermal shock cycles between –55°C and 150°C. The partial dischargeextinction voltage is coordinated for safe isolation to EN 50178.14)External blocking capacitors are to be placed between VISO and VE as well as VE and COM for gatecharges exceeding 3µC. Ceramic capacitors are recommended. A minimum external blockingcapacitance of 3µF is recommended for every 1µC of gate charge beyond 3µC. Insufficient externalblocking can lead to reduced driver efficiency and thus to thermal overload.15)The minimum response time given is valid for the circuit given in the description and applicationmanual (Figs. 5 and 6) with the values of table 1 (C a=0pF, R th=43kΩ).16)The blocking time sets a minimum time span between the end of any fault state and the start ofnormal operation (remove fault from pin SO). The value of the blocking time can be adjusted at pinTB. The specified blocking time is valid if TB is connected to GND.17)This specification guarantees that the drive information will be transferred reliably even at a high DC-link voltage and with ultra-fast switching operations.18)Undervoltage monitoring of the corresponding supply voltage (VCC to GND as well as VISO to VE andVE to COM which correspond with the approximate turn-on and turn-off gate-emitter voltages). If the corresponding voltage drops below this limit, the power semiconductor is switched off and a fault is transmitted to SO.19)Transmission delay of fault state from the secondary side to the primary status output.20)Jitter measurements are performed with input signal IN switching between 0V and 5V referred toGND, with a corresponding rise time and fall time of 5ns.Legal DisclaimerThis data sheet specifies devices but cannot promise to deliver any specific characteristics. No warranty or guarantee is given – either expressly or implicitly – regarding delivery, performance or suitability.CT-Concept Technologie AG reserves the right to make modifications to its technical data and product specifications at any time without prior notice. The general terms and conditions of delivery of CT-Concept Technologie AG apply.1SC2060P2Ax-17Preliminary Data Sheet Ordering InformationThe general terms and conditions of delivery of CT-Concept Technologie AG apply.Type Designation Description1SC2060P2A0-17 Single-channel SCALE-2 driver coreProduct home page: /go/1SC2060PRefer to /go/nomenclature for information on driver nomenclatureInformation about Other ProductsFor other drivers, product documentation, and application supportPlease click: ManufacturerCT-Concept Technologie AGIntelligent Power ElectronicsRenferstrasse 15CH-2504 Biel-BienneSwitzerlandTel. +41 - 32 - 344 47 47Fax +41 - 32 - 344 47 40E-mail ********************Internet © 2008…2011 CT-Concept Technologie AG - Switzerland. All rights reserved. We reserve the right to make any technical modifications without prior notice. Version from 2016-05-20 Page 11。

TH9520 磁性元器件综合分析系统使用说明书

TH9520 磁性元器件综合分析系统使用说明书

使用说明书OPERATION MANUALTH9520集成化磁性元器件综合分析系统TH9520 MAGNETIC COMPONENTEST ANALYZER***********目录第1章概述................................................................................................................................. 1-11.1引言................................................................................................................................. 1-11.2使用条件 ......................................................................................................................... 1-21.2.1 电源 .............................................................. 1-21.2.2 环境温度与湿度...................................................... 1-21.2.3 预热................................................................ 1-21.2.4 几点注意问题........................................................ 1-21.3体积与重量...................................................................................................................... 1-31.4安全要求 ......................................................................................................................... 1-31.4.1 绝缘电阻............................................................ 1-31.4.2 绝缘强度............................................................ 1-31.4.3 泄漏电流............................................................ 1-41.5电磁兼容 ......................................................................................................................... 1-41.5.1 电源瞬态敏感度按GB6833.4的要求。

GC-2060气相色谱仪使用说明书

GC-2060气相色谱仪使用说明书

GC-2060气相色谱仪使用说明书滕州鲁南分析仪器有限公司安全注意事项氢气使用的安全注意事项使用氢气时,需特别小心。

为了防止事故,请严格遵守下述规章:1、气路连接应正确无误。

不可将氢气管道接到仪器的空气入口处,否则氢气将大量泄漏,造成危险。

2、仪器不用时,必须将氢气气源(气瓶或发生器)的总阀关闭,同时要始终保证氢气气源本身无泄漏。

3、任何时候都要注意检查整个氢气气路的密封性,避免出现漏气现象。

4、为防止氢气泄漏引起的爆炸事故,放置仪器的房间必须通风良好,并遵守消防条例的规定。

5、实验完毕后,请首先关闭氢气气源的总阀,然后再进行其它关机操作。

紧急情况下的关机步骤当出现紧急情况而需立即关机时,请按下述步骤操作:1、关闭GC-2060系列气相色谱仪主机电源开关(开关扳至OFF)。

2、关闭所有辅助设备的电源开关(开关扳至OFF)。

3、将所有的气体的气源总阀关闭。

4、拔下仪器电源插头。

紧急情况排除后,重新开启仪器,请参照有关“注意”事项。

安全注意事项本气相色谱仪是用于定性和定量分析的专用仪器。

为了保证仪器的操作安全,请遵守下列注意事项。

1、严格遵守本说明书所列出的操作步骤、警告和注意事项。

2、请按照仪器的设计用途使用仪器。

请不要自行拆卸或改装仪器。

3、仪器的维修,请与滕州鲁南分析仪器有限公司或代理商联系。

注意高热空气仪器工作时,高热空气会从仪器后部的柱箱排气口排出,请勿在排气口周围放置可燃物品。

仪器工作时,进样器、检测器和顶部盖板均处于较高的温度,请勿触摸,否则有烫伤危险。

注意高压危险卸取仪器后盖板之前,必须切断仪器电源。

此项工作最好由本公司的专业维修人员进行。

2安装前的环境要求一、电源要求1、220V±10%2、频率50±0.5H z3、接地要求电阻<10Ω二、气源要求N2(氮气)99.995%H2(氢气)99.995%Air(空气)干燥,无油三、FID操作要求载气:流量20~50ml/min(或参照相应分析方法)氢气:流量25~45ml/min(或参照相应分析方法)空气:流量300~500ml/min(或参照相应分析方法)3目录第一章概述 (1)第二章仪器技术指标 (1)2.1综合参数 (1)2.2温度控制 (1)2.3FID检测器 (2)2.4应用环境 (2)第三章仪器的工作原理 (3)第四章仪器安装 (3)4.1实验室的准备 (3)4.2开箱检查 (4)4.3连接 (4)4.4系统检漏 (5)4.5通电前的检查 (6)第五章仪器操作 (7)5.1气源 (7)5.2气流量调节与测量 (8)5.3色谱柱的安装 (9)5.4键盘操作 (10)第六章汽化室 (13)6.1结构 (13)6.2汽化室温度选择 (13)6.3汽化垫的使用 (14)6.4汽化室的清洗 (14)第七章氢焰检测器(FID) (14)7.1结构 (14)7.2应用范围 (14)7.3气体流量选择 (15)7.4操作 (16)第八章毛细管色谱柱的安装及使用 (18)8.1概述 (18)8.2结构 (18)8.3毛细管色谱柱的安装及使用 (20)8.4玻璃衬管的安装 (22)8.5常见故障及排除 (23)第九章仪器维护保养及常见故障处理 (24)9.1使用与维护 (24)9.2常见故障处理 (25)9.3基线故障处理 (26)4第一章概述GC-2060型气相色谱仪是一种普及型、多用途、高性能的分析仪器,仪器采用双气路双检测器分析系统,可灵活配置各种不同性能的检测器(FID、TCD、ECD、FPD、NPD)等。

高科V2060交换机硬件说明

高科V2060交换机硬件说明

RUN CLK DL1 DL2 DL3 DL4 DL5 DL6 DL7 DL8
DL1-4
SW1 SW1
DL5-8
ACT
SBL
MDPe MCU1 PWU SCU SCU 1V
DTU
B-DTU
3 5
MCU1 MCU1板前面板 PWU板前面板 PWU板前面板
SCU板前、 SCU板前、后面板 板前
MDPe前面板 MDPe前面板 DTU板前、后面板 板前、 板前
高科通信--通信接入专家 高科通信--通信接入专家 --
3
板卡介绍
板名 PWR MCU1 SCU DRV DTU MDPe-2 CDU3 IVR FXS-1 FXSFXOFXO-1 LSW5 描述 电源板 主控板 附机框驱动板 信号驱动板 数字中继板 MFC&DTMF处理板 处理板 模拟来显处理板 语音导航板 用户环路接口板 环路中继接口板 以太网交换板 接线板 B-SCU B-DTU 容 量 +5V和-48V电源 5V和 48V电源 8 × E1 128× MFC/DTMF × 128× MFC/DTMF × 128× 语音总机 × 16 × Telephone 16× 16× 环路中继 10/100Base5 × 10/100Base-T网口
6
V2060机框正面图 V2060机框正面图
高科通信--通信接入专家 高科通信--通信接入专家 --
7
V2060机框背面图 V2060机框背面图
高科通信--通信接入专家 高科通信--通信接入专家 --
8
板卡介绍
板名 CP SW SLC SLE 描述 主控板 电源&E1板 电源&E1板 &E1 用户板 模拟板 接线板 容 量 汇集/ 汇集/处理机框信息 提供2路 接口 音信号、 接口, 提供 路E1接口,音信号、 MFC/DTMF收号器 收号器 15路用户 15路用户 15路环路中继 15路环路中继

回馈式源载系统 IT6000B系列 用户手册说明书

回馈式源载系统 IT6000B系列 用户手册说明书

回馈式源载系统IT6000B系列用户手册型号:IT6000B系列版本:V1.3/06,2020声明©Itech Electronic,Co.,Ltd. 2020根据国际版权法,未经Itech Electronic,Co.,Ltd.事先允许和书面同意,不得以任何形式(包括电子存储和检索或翻译为其他国家或地区语言)复制本手册中的任何内容。

手册部件号商标声明Pentium是Intel Corporation 在美国的注册商标。

Microsoft、Visual Studio、Windows和MS Windows是Microsoft Corporation在美国和/或其他国家/地区的商标。

担保本文档中包含的材料“按现状”提供,在将来版本中如有更改,恕不另行通知。

此外,在适用法律允许的最大范围内,ITECH不承诺与本手册及其包含的任何信息相关的任何明示或暗含的保证,包括但不限于对适销和适用于某种特定用途的暗含保证。

ITECH对提供、使用或应用本文档及其包含的任何信息所引起的错误或偶发或间接损失概不负责。

如ITECH与用户之间存在其他书面协议含有与本文档材料中所包含条款冲突的保证条款,以其他书面协议中的条款为准。

技术许可本文档中描述的硬件和/或软件仅在得到许可的情况下提供并且只能根据许可进行使用或复制。

限制性权限声明美国政府限制性权限。

授权美国政府使用的软件和技术数据权限仅包括那些定制提供给最终用户的权限。

ITECH在软件和技术数据中提供本定制商业许可时遵循FAR12.211(技术数据)和12.212(计算机软件)以及用于国防的DFARS252.227-7015(技术数据-商业制品)和DFARS227.7202-3(商业计算机软件或计算机软件文档中的权限)。

安全声明“小心”标志表示有危险。

它要求在执行操作步骤时必须加以注意,如果不正确地执行或不遵守操作步骤,则可能导致产品损坏或重要数据丢失。

在没有完全理解指定的条件且不满足这些条件的情况下,请勿继续执行小心标志所指示的任何不当操作。

PCS-222B-I_X_说明书_国内中文_国内标准版_X_R1.01

PCS-222B-I_X_说明书_国内中文_国内标准版_X_R1.01

我们对本文档及其中的内容具有全部的知识产权。除非特别授权,禁止复制或向第三方分发。凡侵犯本公司版权等知识产权的,本公司必 依法追究其法律责任。 我们定期仔细检查本文档中的内容,在后续版本中会有必要的修正。但不可避免会有一些错误之处,欢迎提出改进的意见。 我们保留在不事先通知的情况下进行技术改进的权利。
i
PCS-222B-I 智能终端 残余电压
在装置电源关闭后,直流回路中仍然可能存在危险的电压。这些电压需在数秒钟后才会消失。
警示!
接地 装置的接地端子必须可靠接地。
运行环境 该装置只允许运行在技术参数所规定的大气环境中,而且运行环境不能存在不正常的震动。
额定值 在接入交流电压电流回路或直流电源回路时,请确认他们符合装置的额定参数。
本手册中将会用到以下指示标记和标准定义:
危险! 意味着如果安全预防措施被忽视,则会导致人员死亡,严重的人身伤害,或 严重的设备损坏。
警告! 意味着如果安全预防措施被忽视,则可能导致人员死亡,严重的人身伤害, 或严重的设备损坏。
警示! 意味着如果安全预防措施被忽视,则可能导致轻微的人身伤害或设备损坏。 本条特别适用于对装置的损坏及可能对被保护设备的损坏。
P/N:ZL_PCS-222B-I_X_说明书_国内中文_国网标准版_X
购买产品,请联系: 电话:025-87178911 传真:025-52100511、025-52100512
版本:R1.01
ii
南京南瑞继保电气有限公司
目录
PCS-222B-I 智能终端
前言.................................................................................................................................................... i 目录.................................................................................................................................................. iii 第 1 章 概述...................................................................................................................................... 1

CARB 批准的安装、运行和维护手册 - 执行令 VR-201 和 VR-202说明书

CARB 批准的安装、运行和维护手册 - 执行令 VR-201 和 VR-202说明书

C ARB ApprovedInstallation, Operation and Maintenance ManualforExecutive OrderVR-202-X(Assist Phase II EVR SystemIncludingIn-Station Diagnostic (ISD) Systems)NOTICE:The C ARB Approved Installation, Operation and Maintenance Manual for VR-201 and VR-202 describes the tools, method and skill levels required to install both the Assist Phase II EVR System Not Including ISD, C ARB Executive Order VR-201 and the Assist Phase II EVR System Including ISD Systems, C ARB Executive Order VR-202.In addition to the training requirements below, the contractor is responsible for providing the warranty tag, included with each component, to the service station owner/operator at the time of installation. Additional certification may be required in accordance with local district requirements.Unless specified otherwise, only skilled technicians that are trained, certified and licensed by Franklin Fueling Systems (i.e. Healy or INCON Certified Technicians) are able to perform installation, maintenance or repairs of components manufactured by Franklin Fueling Systems or warranty will be void. However, GDF Owner / Operator can remove and install hanging hardware (nozzle, curb hose, breakaway, flow limiter and whip hose).It is the responsibility of each Healy Certified Technician to be familiar with the current requirements of state, federal, local codes and air district rules and regulations for installation and repair of gasoline dispensing equipment.It is also the responsibility of the Healy Certified Technician to be aware of all the necessary safety precautions and site safety requirements to assure a safe and trouble free installation.Unless specified otherwise, only skilled technicians that are trained, certified and licensed by Veeder-Root are able to perform installation, maintenance or repairs of components manufactured by Veeder-Root, or warranty will be void.It is the responsibility of each Veeder-Root technician to be familiar with the current requirements of state, federal, local codes and air district rules and regulations for installation and repair of gasoline dispensing equipment.It is also the responsibility of the Veeder-Root technician to be aware of all the necessary safety precautions and site safety requirements to assure a safe and trouble free installation.It is the responsibility of each INCON Certified Technician to be familiar with the current requirements of state, federal, local codes and air district rules and regulations for installation and repair of gasoline dispensing equipment.It is also the responsibility of the INCON Certified Technician to be aware of all the necessary safety precautions and site safety requirements to assure a safe and trouble free installation.A copy of the Veeder-Root In-Station Diagnostic System Troubleshooting Guide can be found at/object/577013-819.html.A Copy of the INCON VRM Troubleshooting and Diagnostics Guide can be found at /service/pdfs/fms/0000529_VRM_TroubleshootingGuide.pdf.A copy of the Healy EVR Troubleshooting Guide can be found at/service/pdfs/dis/405274001_HealyEVR_TroubleshootingGuide.pdf.To confirm a Healy or INCON Certified Technician training status, a regulator can access a searchable database at the following web site:To confirm Veeder-Root TLS or ISD training a regulator should send an email to****************************** with the name (and company) of the ASC to obtain verification of the ASC TLS/ISD training status or call 800-997-7725 and press “4” to get to the Veeder-Root menu and then “*” to speak to a representative or sign on to the Gilbarco Learning Suite at.TABLE OF CONTENTSAssist Phase II EVR System Installation, Operation and Maintenance Manual Component IOM Manufacturer/ModelScheduled Maintenance 1 Assist Phase II EVR SystemNozzle 2 Healy Model 900Clean Air Separator PressureManagement System3 Healy Model 9961 and 9961HInverted Coaxial Hoses 4 Healy 75 Series Low PermContiTech Futura HVR Low PermVST V34EV ENVIRO-LOC Low Perm Hose Adaptors 5 Healy Model CX6 SeriesRe-connectable Breakaway Couplings 6 Healy Model 8701VVHealy Model 807 SwivelCatlow Model CTMCAVST Model VST-HEVR-SBKVST Model VST-ISVR-SBK (M34 type)Flow Limiters 7 Healy Model 1301Healy Model 1302Dispensers with Healy Model VP1000 Vacuum Pump 8 Gilbarco Encore 300 & 500 SeriesGilbarco GasBoy 9800 SeriesWayne Harmony Series (Balance)Wayne Harmony Series (Assist)Wayne Ovation SeriesWayne Vista SeriesWayne Global CenturyHealy Universal ManualLiquid Condensate Trap19 In-Station Diagnostics (ISD) Systems2Veeder RootIn-Station Diagnostics (ISD) 10 Veeder-RootISDInstall, Setup, & Operation ManualVeeder-Root ISD Vapor Flow MeterInstallation ManualVeeder-Root ISD Pressure SensorInstallation GuideVeeder Root TLS RF Wireless 2 Systems (W2)Installation and Maintenance GuideINCON/FFSVapor Recovery Monitoring (VRM) 11 INCON Vapor Recovery Monitoring (VRM)Installation, Operation, & Maintenance ManualINCON Vapor Flow Meter (VFM)Installation GuideINCON Vapor Pressure Sensor (VPS)Installation GuideINCON Data Transfer UnitDispenser Retrofit ManualINCON Console DTU (Data Transfer Unit)Installation InstructionsINCON/FFS Thermal Printer Model TSSP-TMPTR Retrofit/Installation Instructions1Component optional for vapor recovery system configuration; other requirements may apply2All components listed under ISD components of the Table of Contents are ONLY applicable to Executive Order VR-202 (Assist Phase II EVR System with In-Station Diagnostics Systems).。

CSR-I使用说明书v1.03普通版

CSR-I使用说明书v1.03普通版

⑵ 半双工 RS485,9600bps
DB9 Female 1 2 5 雷达端 导线颜色 棕 白 绿 PC 端 信号 A+ B- GND DB9 male 1 2 5 信号 A+ B- GND
三.常用通信协议
1. 总述 雷达上电复位后输出 FEh FDh FDh FEh,然后进入测速状态。默认测量车速范围 05h~F0h(对应 5~240 km/h) 。在测速状态输入“进入设置状态”命令,可对雷达进行参数设置,完成各种设置后,输 入“退出设置状态”可回到测速状态。 测速状态有三种工作模式,一种持续送数模式,无车持续输出 00h,若车辆通过探测区则输出一 串车速数据,数据间隔约为 26ms。另一种为触发模式,当雷达探测到有车辆通过时,只送 1 次数据, 同时具有输出车速和实时触发功能(具体见后命令) 。第三种是应答模式,只有在测速状态时上位机下 发数据请求 (F7h) 才回送车速数据。 设备出厂默认为触发模式, 车速数据格式默认为单字节 16 进制数, 具体见后命令。 2.设置命令 设置命令基本格式 帧头 FAh 其中x指示具体命令 回 应 帧头 FAh 长度 3xh 内容 帧尾 FBh 命令 3xh 参数(2字节) yyh yyh 帧尾 FBh
卓越的产品性能
-4-
可靠的产品质量
专业的技术服务
优秀的品牌形象
北 京 川 速 微 波 科 技 有 限 公 司
3)监测雷达上电瞬间,在通信区域 3 中是否出现上电标识 0xFE、0xFD、0xFD、0xFE。如显示正常, 雷达处于测速状态,可以进行探测目标。 4)如需进行参数设置或调试,点击“进入设置状态”按钮,在设置状态中相关参数在通信设置区域 中调整:
CSR﹣I 系列 平板型微波测速雷达 产品使用说明书

c2060使用手册

c2060使用手册

c2060使用手册
(实用版)
目录
1.C2060 概述
2.安装与配置
3.使用方法
4.维护与保养
5.故障排除
正文
【C2060 概述】
C2060 是一款性能卓越的设备,其设计理念是满足用户的多样化需求。

本手册将为您提供有关 C2060 的详细信息,包括安装、配置、使用方法
以及维护与保养等方面。

通过阅读本手册,您将更好地了解 C2060,并能充分挖掘其性能潜力。

【安装与配置】
在开始使用 C2060 之前,首先需要进行设备的安装与配置。

本部分
将详细介绍安装过程,包括硬件安装和软件配置。

请按照手册中的步骤操作,确保正确安装设备。

【使用方法】
C2060 设备的使用方法非常简单。

在本节中,我们将详细介绍如何操作 C2060,包括基本功能和高级功能的使用。

通过学习本节内容,您将轻松掌握 C2060 的操作方法。

【维护与保养】
为了确保 C2060 设备的长期稳定运行,需要定期进行维护与保养。

本部分将为您提供一些建议和方法,包括清洁、检查和更换易损件等。

遵循这些建议,可以有效延长 C2060 的使用寿命。

【故障排除】
在使用 C2060 的过程中,可能会遇到一些问题。

本部分将提供一些常见故障的排除方法,帮助您解决遇到的问题。

如果遇到手册中未列出的故障,请随时联系我们的技术支持团队,我们将竭诚为您提供帮助。

通过阅读本手册,您应该已经对 C2060 有了充分的了解。

高科V2060-B语音专线接入设备使用说明书

高科V2060-B语音专线接入设备使用说明书

广 州 市 高 科 通 信 技 术 股 份 有 限 公 司Guangzhou Gaoke Communications Technology Co.,LTD.Vango2060V2060-B 数字程控用户交换机使用说明书V2060-B 数字程控用户交换机使用说明书产品:V2060-B-04-12-361广州市高科通信技术股份有限公司热情为客户提供全方位的技术支持,用户可与就近的高科办事处联系,也可直接与公司客服部联系。

广州市高科通信技术股份有限公司电话:总机(020)82598555、客服部(020)82598119传真: (020)82598733 (020)82599989网址:E-mail:gaoke@版权声明广州市高科通信技术股份有限公司版权所有,保留一切权利。

非经本公司书面许可,任何单位和个人不得擅自摘抄、复制本书内容的部分或全部,并不得以任何形式传播。

®为广州市高科通信技术股份有限公司的商标,不得仿冒。

Copyright by Guangzhou Gaoke Communications Technology Company Limited.All rights are reserved.No Part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Guangzhou Gaoke Communications Technology Company Limited.®is the trademarks of Guangzhou Gaoke Communications Technology Company Limited.No the trademarks may be counterfeited.免责声明广州市高科通信技术股份有限公司保留修订本出版物和随时修改本文档内容而不预先通知任何人的权利。

ZZEBEX Handheld Computer Z-2060 系列手机 说明书

ZZEBEX Handheld Computer Z-2060 系列手机 说明书

Handheld ComputerZ-2060系列( Version 2.00 )用户手册ZEBEX INDUSTRIES INC.目录前言手册说明 (5)标识说明 (5)版权声明 (6)安全信息 (6)镭射安全 (6)安全提示 (7)联邦通讯委员会(FCC) 声明 (8)拆包产品清单 (9)可选配件 (10)底座部分 (10)可额外采购件 (11)一般指南 (13)使用前准备安装电池 (15)取下电池 (15)电池充电 (16)通过数据线充电 (16)通过底座充电 (16)电池单独充电 (17)系统初始化 (19)热启动 (19)冷启动 (19)PC系统需求 (20)连接至PC (20)通过RS232数据线连接至PC (20)通过USB 底座连接至PC (21)通过Mini USB数据线连接至PC (21)安装SD卡 (22)取下SD卡 (22)关于本产品 (23)特性 (23)产品参数表 (24)使用条码扫描器扫描条码 (25)使用Zebex PowerPackBacklight背光 (26)Calculator计算器 (28)File Transfer文件传递 (29)文件传递范例 (30)Launcher快速启动 (33)快速启动范例 (35)Switch无线/蓝牙开关 (39)TrayScan扫描开关/条码设置 (40)Backup/Restore备份/恢复 (44)Firmware Information版本信息 (46)Shortcut Manager快捷键/功能键............................................. (47)购买指南 (53)前言手册说明感谢你选用ZEBEX 公司Z-2060系列移动数据产品。

ZEBEX Z-2060系列采用最前沿的手持数据终端技术, 请仔细阅读本手册,本手册向您提供正确使用本设备多样化功能的必要信息。

Z-2060 系列数据采集器设计的非常简洁, 符合人体工程学和机器稳定性的要求。

EIP-2060快速入门指南说明书

EIP-2060快速入门指南说明书

EIP-2060CDScrew DriverThe package includes the following items:Install EIP-2000 Utility:The software is located at:Fieldbus_CD:\EtherNetIP\remote-io\EIP-2060\UtilityQuick Start Guide (This Document)2I nstalling software on your PC1.Make sure your PC has workable network settings.2. Disable or well configure your Windows firewall and anti-virus firewall first, else the“Network Scan ” on step 4 may not work. (Please contact with your system Administrator)3. Check FW/OP DIP switch if it is on OP position.4. Connect both the EIP-2000 and your computer to the same sub network or the sameEthernet switch, and power the EIP-2000 on.3C onnecting the Power and PC5.I/O connector – EIP-20606.I/O Wire Connection1.Double click the “EIP -2000 Utility ” shortcut on the desktop. 2. Click the “Network Scan ” button to search your EIP-2000 modules.3. Click the EIP-2060 or other EIP-2000 modules on the device list below to open theconfiguration dialog of EIP-2000. Each EIP-2000 module has its own configuration interface.4. Test the digital outputs by clicking on the red circles, and the green circles indicate thestatus of digital input status. 4Using the EIP-2000 Utility5.The “Power On Value”, “Safe Value”and “Safe Delay”for digital output can be setwithout rebooting the module.6.If the network settings have been changed, please click the “Update Network Settings”button to update the configuration and reboot the module.1. Open RSLogix 5000 and create a new project.Figure5-1. Create a new project.2. Select the PLC type and give the project a name.Figure5-2. Set the PLC type and project name.5How to connect with Allen-Bradley PLC ?3.Create a new module in the “Ethernet” item.Figure 5-3. Create a new module.4.Select the “ETHERNET-MODULE” below “Communications” in the Select Modulewindow.Figure5-4. Select “ETHERNET-MODULE”.5.Configure the new module parameters. The I/O length of new module must be the same with the length of EIP-2060 I/O data(Table 5-1). The input data size is 26 bytes and output data size is 2 bytes. The instance ID please refer to Table 5-2.Figure5-5. The settings of EIP-2060 module。

ICP DAS CAN-2060C用户手册说明书

ICP DAS CAN-2060C用户手册说明书

CANopen Slave DeviceCAN-2060CApplication User’s ManualWarrantyAll products manufactured by ICP DAS are under warranty regarding defective materials for a period of one year from the date of delivery to the original purchaser.WarningICP DAS assumes no liability for damages resulting from the use of this product. ICP DAS reserves the right to change this manual at any time without notice. The information furnished by ICP DAS is believed to be accurate and reliable. However, no responsibility is assumed by ICP DAS for its use, or for any infringements of patents or other rights of third parties resulting from its use.CopyrightCopyright @2015 is reserved by ICP DAS.TrademarkThe names used for identification only may be registered trademarks of their respective companies.Table of Contents1.Introduction (3)1.1Overview (3)1.2Hardware Specifications (4)1.3Features (5)1.4Application (5)2.Hardware (7)2.1Structure (7)2.2Node ID & Baud Rate Rotary Switch (8)2.3LED Description (9)2.4PIN Assignment (10)2.5Wire Connection (10)3.Application (12)3.1Object Dictionary (12)3.2Store and Restore Object (15)3.3Application Object (16)3.4Default PDO Mapping (20)1. Introduction1.1OverviewCANopen is one kind of the network protocols based on CAN bus and mainly used for embedded system, such as industrial machine control, vehicle control system, factory automation, medical equipments control, remote data acquisition, environment monitoring and package machines control.The CAN-2060C is a CANopen slave which follows the CiA 301 version 4.02 and CiA 401 version 2.1.It is easy to access the digital I/O status and set the configuration by using standard CANopen protocol. CAN-2060C has passed the validation of the CiA CANopen Conformance Test tool. Therefore, the provided EDS file is standard for any other standard CANopen masters. CAN-2060C has 4-channel isolated sink/source input and 4-channel relay output. By owing to the CANopen masters of ICP DAS, you can quickly build a CANopen network to approach your requirements.Figure 1-1 CAN-2060C1.2Hardware SpecificationsRelay Output●Output channels: 4 (Source)●Resistive Load : 5A/30 V DC,5A/250 V AC●Insulation Resistance: 1,000MΩs at 500 V DC●Output Type: Form A (SPST-NO)●Intra-module isolation: 3750 Vrms●Reaction Time:⏹Operate Time: 10ms max⏹Release Time: 5ms max●ESD Protection 4 KV Contact for each channelDigital Iutput●Input channels: 4 (Sink/Source)●DI On Level: +3.5 ~+30 V DC●DI Off Level: +1 V DC Max.●Input Impedance: 3kΩ ,0.3W●Intra-module isolation: 3750 Vrms●Response Time:⏹Rising edge to DI response: 75 us⏹Falling edge to DI response: 180 us●ESD Protection 4 KV Contact for each channelOthers●CANopen Status: 3 LEDs for PWR / RUN / ERR●Terminal Resister: 1 LED as terminal resister indicator●DI LED: 4 LEDs as digital input indicator●DO LED: 4 LEDs as relay output indicator●Power supply: Unregulated +10~+30 V DC●Power Consumption: 1.5W●Operation Temperature: -25 ~ 75 ℃●Storage Temperature: -35 ~ 80℃●Humidity: 10~90% RH, Non-condensing●Dimensions: 32.5mm × 110mm × 102 mm (W×L×H) Detail.1.3 Features●Standard CANopen general I/O slave devices●CANopen Version: CiA-301 ver4.02, CiA-401 ver2.1●Support I/O pair-connection mechanism●Provide normal/polarity 4 DI channels and 4 Relay channels●CANopen transfer rate: 10k bps, 20k bps, 50k bps, 125k bps, 250k bps, 500kbps, 800k bps, 1000k bps●Support maximum CANopen slave device Node-ID up to 99●Set Node-ID 0 for firmware update⏹Firmware update tools:I-7530 series, I-7540D series, I-7565 series,PISO-CM100 series and PISO-CAN series●Support NMT, PDO, SDO, EMCY, SYNC, Guarding and Heartbeat protocol●Pass the validation of CANopen conformance test●Provide EDS file for CANopen master interface1.4 Application●Measuring Temperature●Medical technology●Utility vehicles2. Hardware 2.1 Structure(Top View)(Botton View)2.2 Node ID & Baud Rate Rotary SwitchThe rotary switches for node ID configure the node ID of the CAN-2060C module. These two switches are for the tens digit and the units digit of node ID. The node ID value of this demo picture is 32.The rotary switch for baud rate handles the CAN baud rate of the CAN-2060C module. The relationship between the rotary switch value and the practical baud rate is presented in the following table.2.3 LED DescriptionPower LEDThe CAN-2060C needs a 10VDC ~30VDCpower supply. Under a normalconnection, a good power supply and a correct voltage selection, as the unit it turned on, the LED will light up in red.Run LEDThe Run LED indicates the CANopen operation state. The description of the LED state is shown below. About the details, please refer to the section 2.3.1 of the CAN-2000C user manual.Error LEDThe Error LED indicates the CANopen error state. The description of the LED state is shown below. About the details, please refer to the section 2.3.2 of the CAN-2000C user manual.Terminal Resistor LEDWh en the switch of the 120Ω terminal resistor is turned on, the terminal resistor LED will be lightening.2.4PIN Assignment2.5Wire Connection3. Application3.1Object DictionaryGeneral Communication EntriesTable 3-1SDO Communication EntriesTable 3-2 RxPDO Communication EntriesNote: Object 0x2030h is used for DI noise. If there is any DI noise in your application, you can set the value larger to avoid the unexpected noise.Table 3-93.2Store and Restore ObjectUser can write the value 0x65766173 to the object index 0x1010 to save configuration setting, or write the value 0x64616F6C to object index 0x1011 to load the factory default. The following table lists the relative objects which will be stored or restored after writing these two objects. The factory default for these objects is also shown.C ommunication Setting:Please refer to above table 3-3, 3-4, 3-5 and 3-6.Application Setting:3.3 A pplication ObjectDigital Input module (0x6000) User can use the object index 0x6000 with subindex 1 to read a group of 8-bit information.For example, if the node id of CAN-2060C is 1, the commands are as below:Read the object index 0x6000 with subindex 1, and the digital value 0x0F will beresponded by CAN-2060C module. The DI channels of DI3, DI2, DI1 and DI0 are turn on and others are turn off.Change Input polarity (0x6002) User can configure the object index 0x6002 with subindex 1 to set the polarity of DI channels. The object 0x6002 with subindex 1 defines the polarity of a group of 8 input lines. Input polarity can be inverted individually.1 = input inverted 0 = input not invertedFor example, if the node id of CAN-2060C is 1, the commands are as below:SDO server(CAN-2060C)SDO clientWrite object index 0x6002 with subindex 1 to 0x0F means that set the Ch0~ Ch3 of DI channels to normal, and set the Ch4 ~ Ch7 to be inverted.Digital Output module (0x6200) User can set a group of 8 output lines as a byte of information and sent it into the object index 0x6200 with subindex 1 of CAN-2060C. For example, if the node id of CAN-2060C is 1, the commands are as below:Write the 0x0F of digital output value into the object index 0x6200 with subindex 1, and its response success by CAN-2060C.Change Output polarity (0x6202) The object 0x6002 with subindex 1 defines the polarity of a group of 8 output lines. Output polarity can be inverted individually. 1 = input inverted 0 = input not invertedFor example, if the node id of CAN-2060C is 1, the commands are as below:SDO server (CAN-2060C)SDO clientWrite object index 0x6202 with subindex 1 to 0xF0 means that set the Ch0~ Ch3 of DO channels to normal, and set the Ch4 ~ Ch7 to be inverted.Error Mode and Error Value(0x6206, 0x6207) The object 0x6206 and 0x6207 are used to control the safe value when error happens. When some error event of this module happens such as node guarding failure, the module will check the value of the object 0x6206. If some bits of this value are set to 1, the corresponding DO channels will be into error mode output. The error mode output values are concerned to the object 0x6207. For example, if the subindex 01 in the object with 0x6206 and 0x6207 are 0x31 and 0xF8 respectively, when some error event occurs, only the DO5, DO4, DO0 will be changed to error mode output because the bit 5, bit 4, and bit 0 of the value 0x31 is 1. The others channels keeps the status as the error event is not happened. The bit 5, bit 4, and bit 0 of the value 0xF8 are 1, 1 and 0, therefore the error mode output value of DO5, DO4 and DO0 are active, active, and inactive respectively.SDO server (CAN-2060C)SDO clientSDO server (CAN-2060C)SDO clientWrite object index 0x6206 and subindex 1 to 0x31 means set the error mode to 0x31 for enabling the error mode output of DO 0, DO 4 and DO5.Write object index 0x6207 and subindex 1 to 0xF8 means set the error value to 0xF8 for activating the error mode output value of DO 3 ~ DO 7. If the error event in this module, the module will output the safe value 0x30 (0x31 & 0xF8 = 0x30) corresponding the object 0x6206 and 0x6207.Set Power On Value (0x2010)This object 0x2010 with subindex 1 defines the power on value of a group of 8 output lines. Power on value can be set individually.For example, if the node id of CAN-2060C is 1, the commands are as below:SDO server (CAN-2060C)SDO clientSDO server (CAN-2060C)SDO clientWrite object index 0x2010 with subindex 1 to 0x0F means that set the Ch0 ~ Ch3 of DO channels to 1 when the CAN-2060C power on.3.4 Default PDO MappingRxPDO mapping list:Note: x is node id of CAN-2060C moduleTxPDO mapping list:Note: x is node id of CAN-2060C module。

c2060使用手册

c2060使用手册

c2060使用手册摘要:1.C2060 概述2.安装与配置3.使用方法4.维护与升级5.安全与注意事项正文:【C2060 概述】C2060 是一款先进的中文知识类写作助手,旨在为用户提供高效、准确的文本生成服务。

本手册将为您详细介绍如何使用C2060 以满足您的写作需求。

【安装与配置】在开始使用C2060 之前,您需要进行以下安装与配置工作:1.下载并安装C2060 客户端:访问官方网站下载最新版本的C2060 客户端,并按照提示进行安装。

2.注册并登录:使用您的账号登录C2060 客户端。

如果您还没有账号,请先进行注册。

3.设置偏好:根据您的写作习惯,设置好语言风格、主题偏好等相关参数。

【使用方法】在完成安装与配置后,您可以开始使用C2060 进行文本创作:1.输入文本主题和关键词:在C2060 客户端的主界面,输入您想要写作的主题和关键词,点击“生成”按钮。

2.查看生成的文本:C2060 会根据您的输入生成相应的文本,并在界面中展示。

您可以查看、修改并保存生成的文本。

3.复制粘贴:如需将生成的文本复制到其他文档中,只需选中文本并使用快捷键Ctrl+C 进行复制,然后在目标文档中使用Ctrl+V 进行粘贴。

【维护与升级】为了确保C2060 能够持续稳定地为您提供服务,您需要定期进行以下维护与升级工作:1.更新客户端:访问官方网站,查看是否有最新版本的C2060 客户端,并按照提示进行更新。

2.备份数据:定期备份您的账号信息和生成的文本,以防数据丢失。

【安全与注意事项】在使用C2060 时,请注意以下安全与使用事项:1.保护账号安全:使用复杂且不易被破解的密码,并定期更改密码。

2.遵守法律法规:使用C2060 生成的文本时,请确保内容符合我国相关法律法规,不得传播违法信息。

3.文本审核:在使用生成的文本前,请进行仔细审核,确保内容准确、无误。

通过以上介绍,相信您已经对C2060 有了充分的了解,可以开始尝试使用它来提高您的写作效率。

c2060使用手册

c2060使用手册

c2060使用手册摘要:1.C2060 简介2.C2060 功能特点3.安装与配置4.使用方法5.维护与保养6.故障排除正文:【C2060 简介】C2060 是一款先进的中文知识类写作助手,专为提高用户的写作效率和质量而设计。

它集成了多种功能,可以帮助用户进行文本分析、撰写、排版和校对,适用于各种写作场景,如学术论文、报告、散文等。

【C2060 功能特点】C2060 具有以下功能特点:1.强大的文本分析能力:C2060 可以对输入的文本进行深入分析,识别出主题、关键词、句式等,为用户提供有益的写作建议。

2.自动化写作:根据用户输入的关键词和主题,C2060 可以自动生成相应的文章框架,用户只需稍作修改和补充,即可完成高质量的写作任务。

3.实时排版与校对:在用户写作过程中,C2060 可以实时进行排版和校对,确保文章的格式规范和语言准确性。

4.丰富的知识库:C2060 拥有海量的中文知识库,覆盖各个领域的专业词汇和表述,助力用户写出权威、专业的作品。

5.智能升级:C2060 具备自我学习和升级功能,通过不断吸收新知识,可以更好地满足用户日益提高的写作需求。

【安装与配置】1.下载安装程序:访问官方网站下载C2060 安装程序。

2.安装过程:运行安装程序,按照提示进行操作,即可完成安装。

3.配置:安装完成后,启动C2060,根据提示进行相关设置,如输入法、默认语言等。

【使用方法】1.打开C2060:在桌面或开始菜单中找到C2060 图标,双击打开。

2.输入文本:在主界面的文本框中输入要分析或撰写的文本。

3.使用功能:根据需要,点击相应功能按钮,如分析、撰写、排版等。

4.查看结果:在文本框下方的预览窗口中查看生成的文章或排版效果。

5.保存与导出:完成写作后,点击“保存”按钮将作品保存在本地,或选择“导出”按钮将作品导出为Word、PDF 等格式。

【维护与保养】1.定期升级:为了保持C2060 功能的完整性和及时性,建议用户定期进行升级。

GC-2060气相色谱仪操作规程

GC-2060气相色谱仪操作规程

GC-2060气相色谱仪操作规程1.目的规范GC-2060气相色谱仪的使用。

2.范围适用于GC-2060气相色谱仪的使用。

3.职责质检员对本规程的实施负责。

4.规程4.1 系统组成:4.1.1气源部分:包括SPH-200氢气源发生器、SPB-3空气源发生器、氮气钢瓶及减压阀。

4.1.2气相主机:包括氢火焰离子化检测器(FID)。

4.1.3计算机及N2000色谱数据工作站、不间断电源等辅助设备。

4.2 操作前的准备4.2.1 检查气相色谱仪各部件是否正常,各部件是否安装好。

4.2.2 色谱柱的安装:按实验需要,参照说明书进行安装色谱柱。

(新柱老化时,将其进样口一端接入进样器接口,另一端放空在柱箱内,检测器一端封住。

新柱在低于最高使用温度20~30℃以下,通过较高流速载气老化24小时以上。

安装时注意松紧度,安装后打开载气阀,仪器在正常通气情况下用皂液检漏。

)4.2.3检查气路系统密封性能,可用皂液检漏,防止漏气事故发生。

4.3操作步骤4.3.1开启氮气钢瓶阀,通过减压阀调节到0.35~0.40MPa 。

4.3.2接通电源,开启SPB-3空气源发生器与SPH-200氢气源发生器电源,空气调节空气输出压力至约0.25 Mpa。

4.3.3 GC-2060气相色谱仪主机操作4.3.3.1开启主机电源开关,进入正常操作程序。

4.3.3.2 按主机键盘上[温度]键,用[↑]或[↓]键上下移动将光标移至柱温或气化室温度或检测器或程序升温处,用数字键和小数点键填入需要设定的参数,再按[送数]键将填入的数字植入到微机,依次设定所要求设定的柱温、气化室温度、检测器温度、程序升温参数。

(不需程序升温时只需要前3部分操作)4.3.3.3按主机键盘上[加热]键预热升温。

4.3.3.4等柱温箱温度达到设定值后,通过控制GC-2060气相色谱仪主机上氢气Ⅰ旋钮,调节SPH-200氢气发生器的氢气流量至50mL/min左右,用点火枪对准点火处点火。

淘汰式柔性耐用汽燃燃煤机用户指南说明书

淘汰式柔性耐用汽燃燃煤机用户指南说明书

CONTENTS PrefaceSafety InformationEngine SpecificationsSafety Label LocationAssemblingEngine UsageStart the EngineElectric Wiring DiagramRun the EngineStop the EnginePeriodicaI Check and MaintenanceLong-term StorageDetail DiagramAppendix 1.Overall and lnstallation Dimensions Appendix 2.Performance Curve & Sizes Of Pto Flanges Appendix 3.Sizes of PTO Flanges & Size of Output Shaft Appendix 4.Malfunction and remedy of diesel engine Limited WarrantyProduct Registration Card1 2 2 3 6 12 13 14 15 18 19 36 36 36 37 41 42Main ItemsTypeCombustion SystemBore x Stroke(mm)Piston Displacement(L)Rated PowerMax.kW(PS)Continue.kW(PS)Rated Speed(rpm)Rotation directionSpray Pressure kg/cm2(MPa)Applicable Fuel OilFuel Tank Capacity(L)Lubricating MethodApplicable Lube OilLube Oil Capacity Full(L)Effective(L)AHD186Single-cylinder,4-stroke,vertical,air-cooled,direct-injection diesel engineDirect injection combustion86 x 720.4189.08.53600Unclockwise viewed from the output shaft200(19.6)Light diesel5.5Pressure plus splashingSAE 10W30 beyond CC grade1.650.6Output ShaftFuel OilLubricating SystemStarting System Cooling System Recoil starter or Recoil/Electric starterForced air-cooledAMICO 3.ASSEMBLINGFUEL OIL CAPACITY ModelOil drain screw plug Dipstick air cleaner cover Wing nutelementfuel cock ("OPEN")regulator handlestarterhandlerecoil starterstarterhandlerecoil starterOpen the fuel cock.Put the engine speed leverin the "RUN" positionHold the starting handleloosely until you feelresistance Then return it slowly.Push the decompressionlever down and release Hold the starting handle firmly.Pull the rope hard and fast Pull it all the way e two hands if necessary.Pull the startinghandle slowly ......Start!If the engine doesn't starttry again from (1)23456For3, don't pull the ropetoo fast or hard.Always pull the rope slowly.For5,if you don't pull the ropeall the way out ,the engine won'tstart Always pull the rope all theway out.Always pull the rope hardand fast.For5,if you don't pull hard enough,the engine won't startSTART THE DIESEL ENGINEstandard panel installation panel of the cylinder head casehexagonal bolt M6 x 70removetwo boltslongwasherASSEMBLY:NO. Specification Quantity1 Electric starting switch body 12 Electric starting switch panel 13 Long washer 24 Hexagonal bolt M6 x 70 2PROCEDURES:Remove the electric starting switch body from thestandard panel, then reassemble it to the installa-tion panel of the cylinder head case.Screw off the two bolts from the cylinder head case.Clip the reassembled panel with the long washer,then tight it with hexagonal bolts.[OPERATING NOTICE]If the wire harness touch the muffleror the PTO shaft, the fire will result.Set the earth terminal of the harness with M6 bolt.1234groundterminalsM6 bolt couplerwire harness123ELECTRIC WIRING DIAGRAMblue redgeneratorblue blueredblue starting key of diesel engineyellowredregulatoryellowred black12Vstarting motoraccumulatorwhiteblackgray6.Run the EngineTo prevent the exhaust toxication, be sure to run the engine at ventilated place.To prevent personal injury, avoid hands, personal body and cloths from involving into the output shaft, pulley and V pulley etc moving parts.Check the moving parts and the surrounding parts after stop the engine. Be sure that there is no tool or cloth inside the engine body.The muffler is very hot during running or just after running, do not touch the muffler.The air cleaner will suck the surrounding airflow during the running. To prevent the injury, avoid hands, personal body and cloths approach this part.Warm up the engine for 5 minutes.If the engine is very hot, set the governor lever to the expected position.Be sure to regulate the engine speed with the governor lever.Do not screw off the adjusting bolt and the fuel adjusting bolts, otherwise the abnormal speed and output will result.If the engine continually exhaust black smoke dur-ing running, which indicates that the engine is run-ning with overload, do adjust the engine pulley andthe load pulley.speed limiterF.O. limiter!WARNING!CAUTION!NOTE!NOTE123PLEASE PAY ATTENTION TO THE FOLLOWING ITEMS WHILE RUNNING:Whether there is abnormal vibration and sound.Whether the exhaust is normal.Whether the engine continually exhausts white smoke or black smoke.Be sure to shut off the engine when the abnormal phenomenon arouses,and contact with agent.7.STOP THE ENGINEIf the engine is stopped in emergency, theengine temperature will rise quickly, thusthe engine life will be shortened.Fill diesel to the tank.Check all the bolts and nuts. Screw on them if necessary.Clean the dirty on the surface of the engine body.regulator handle fuel tank fuel cock("OPEN")[OPERATING NOTICE]Set the governor lever to the low speed position,then run the engine at zero load five minutes.Set the governor lever to the *STOP *position. Donot stop the engine with the decompression lever.Set the fuel cock to *OFF *position.Pull the recoil starter handle slowly, until you feelresistance. (At this point, the decompression justbegins and intake/exhaust valves are both closed,thus the cylinder can be prevented from rust.)Concerning the electric starting engine, directlyturn the starting key to *OFF *position.PREPARE FOR THE NEXT OPERATION:123123451238.Periodical Check and MaintenancePeriodical Check and maintenance are very important for maintaining the performance and life of the engine.The following is the maintenance intervals and items table.The item with "." require technician or special tools,please contact with agent.Periodical check and maintenance table:IntervalsItemsCheck all the bolts and nutsCheck and refill engine oilReplace engine oilClean or replace engine oil cleanerCheck oil leakage Replace air cleaner Clean fuel oil cleanerCheck nozzleCheck fuel injec-tion pump Adjust the clearance of the intake/exhaust valve Check the intake/ exhaust valve Replace the piston ringCheck the electrolyte every day20hrs50hrs100hrs200hrs500hrs1000hrs Check it every month,refill the distilled water if necessary.(First time)(Second time)(Clean)(Clean)(Replace)(Replace)Replace Engine OilDrain out the engine oil while the engine is warmand refill the recommended engine oil.Ambient temperature Grade Viscosity Above 20 C (Summer) Beyond CC grade SAE 3010 C~20 C (Spring and fall) SAE20Below 10 C (Winter) SAE10W-30Replace Engine Oil IntervalsFirst time 20 hrsSecond time Every 100 hrs Clean Engine Oil CleanerScrew off the bolt and take out the engine oilcleanerClean Every 100 hrsReplace Every 1000hrs186Oil drain scew plug DipstickScrew off the bolt and take out the engine oil cleaner.oil filterLO suction pipeO ring lock boltReplace the air cleanerA. Paper element:Replace the element every 500 hrs.air cleaner coverwing nutIf the element is too dirty, the air flow will be blocked and starting will be hard, thus insufficient output will result, further more, it will cost both fuel oil and engine oil, the engine will exhaust black smoke.Running engine with worn element or without element is not allowed.B. Oil-soak Type ElementCheck the engine oil level before run the engine. Refill the engine oil until the upper level. Re-place if it is too dirty. Often clean the element with kerosene, then soak it in the engine oil and squeeze out the excess engine oil.Oil filterOil-soak Type ElementOil levelClean the Fuel Oil CleanerRemove the fuel oil cleaner from the tank and clean it on time.Clean Every 500 hrs Replace Every 1000 hrs A. Completely drain out the fuel oil.B. Screw off two nuts of the fuel cock and take out the fuel oil cleaner.Screw on the bolts on the cylinder head. This operation requires special tools, please contact with your agent.Oil drain screw plugDrain plug fuel cock bolt!CAUTION2154The adjustment of fuel nozzle and fuel injection pump and the replacement of the valve seats, parts require special technology, please contact with your agent.Check the battery every month.9.LONG-TERM STORAGEPrepare the following items before long-term storage:Remove the filler screw plug on the cylinder head case and refill about 2cc engine oil.Clean off the dirty on the engine surface, then store the engine at the dry place.Oil drain screw plugDipstickdecompression leverRun the engine five minutes at low speed.Drain out the engine oil while the engine is warm and refill the fresh engine oil.Press down the decompression lever and pull the recoil starter 2-3 times(Do not start the engine)Return the decompression lever back to the de-compression position, and pull the recoil starter slowly until you feel the resistance.(At this point,both intake/exhaust valves are closed to prevent the engine from rust.)67123456starter handlerecoil starter10.DETAIL DIAGRAMQty.1111111Ref No.1234567Part No.186F ~ 18003186F ~ 18004186F ~ 18005186F ~ 18007186F ~ 18009186F ~ 18012186F ~ 18013Description Trade Marks Tag I Start Operation Tag Caution Tag Model Tag Warning Tag Air Cleaner TagAir Cooled Diesel Engine Tag CAUTIONAIR-COOLED DIESELHOW TO STARTCAUTIOND IE SE LD IE S ELWARNING6751324Torque 40~4554-58120~1358 ~1020~2210~1218~22 ITorque of Main Bolt & Nut Ref No.1234567DescriptionRod Bolt Nut Cyl Head Nut Flywheel Nut Nozzle Retainer Nut Rocker Arm Tighten Stud Bolt M6 (Nut)Bolt M8 (Nut)Unit:N. m Qty.11212Bearings Ref No.u v w x YPart No.GB ! T276-94GB/T276-94GB290-89GB290- 89GB / T276- 94Description Ball Bearing 6308/P5Ball Bearing 6207/P5Needle Bearing HK081210Needle Bearing HK1512Ball Bearing 6203Rings Ref No.m n o P q r s t Part No.186F-01007GB3452.1-92GB3452.1-92GB3452.1-92GB3452.1-92GB3452.1-92GB3452.1-92GB3452.1-92Description O-RingZ O-Ring 11 x 1.9G O-Ring 24 x 2.4G O-Ring 10 x 1.9G O-Ring 25 x 2.4G O-Ring 34.5 x 1.8G O-Ring 13.2 x 1.9G O-Ring 12 x 1.8G Qty.11211111Full Gasket SetsQty. 1Ref No.1Part No.186F-11008Description Lever shaft SealFull Gasket Sets Qty.21111111111Ref No.a b c d e f g h i J kPart No.186F-01100186F-10017186F-10016186F-01015186F-02014186F-02015186F-03003186F-07001186F-09002186F-10007186F-10013DescriptionOil Plug Gasket Assem.Fuel Injection Pump Shim Set Seal GasketCrank Case GasketAir Intake GasketExhaust GasketBonnet GasketAir Cleaner GasketOil Filter Plate GasketFuel Oil Filter GasketConnecting Plate GasketMounted to(4)Piston & Connecting Rod Assem.(4)Piston & Connecting Rod Assem.(4)Piston & Connecting Rod Assem.(4)Piston & Connecting Rod Assem.(1)Cylinder Block Assem.(13)Fuel Nozzle Assem.(2)Cylinder Head Assem.(ll)Fuel Tank & Pipe Assem.(7)Air Cleaner Assem.(1)Cylinder Block Assem.(1)Cylinder Block Assem.(14)Recoil Starter Assem.Ref No.A B C D E F G H I J K LPart(Type) No.186F-04100186F-04001186F-04002186F-04005GB9877 ~ 1-8811.433 ~ 172.001186F-02007186F-t0300186F-07100186F-0t012GB9877 ~ 1-88186F-14008Description Oil Ring Set First Gas Ring Second Gas Ring Crank Pin Bearing Oil Seal B355010D Nozzle SpacerFilter Element Assem.Air Cleaner Element Assem.Cyl. Head Gasket Oil Seal B355008D Starter RatchetQty. 1 1 1 2 1 1 1 1 1 1 1 1Easy Worn Parts(1)Cylinder Block AssemblyDescriptionDrain PlugOil Plug Seal Assem.Oil Seal B355010D Cylinder BlockFuel Controller Assem.O-Ring 24 x 2.4Oil Depth GaugeNut M10 x 1.25Tighten Stud(Short) Tighten Stud(Long)Shim SetNut M6Seal GasketSeal PlateBall Bearing 6308 RetainerBolt M8 x 12Needle Bearing HK152015 Cylinder Head Bolt(Shortl WasherCyl. Head Nut(Short) Cyl. Head GasketCyl.Head Nut(Long)Bolt M6 x 20Air CoverO-RingCyl.head Bolt(Long) Crank Case GasketBall Bearing 6207-P5 Main BearingPin8 x 10Crank Case CoverOil Seal B355008DBolt M8 x 30PlugBolt M8 x 33.5PlungerNeedle Bearing HK081210Qty. 2 2 1 1 1 2 2 1 1 2 2 3 1 1 1 1 1 1 2 4 2 1 2 2 1 1 2 1 1 1 2 1 1 2 1 13 3 1Ref No.12345678910111213141516171819202122232425262728 28-1293031323334353637Part No.186F-01017 186F-01100 GB9877.1-88 186F-01001 186F-11200 GB3452.1-92 186F-01002 GB6173-86 186F-01012 186F-01001 186F-10017 GB6170-86 186F-10016 186F-10015 GB/T276-94 186F-01009 GB5783-86 GB290-89 186F-01003 186F-01005 186F-01004 186F-01013 186F-01007 GB5787-86 186F-01211 186F-01008 186F-01006 186F-01015 GB/T276-94 186F-01014 GB 119-86 186F-01016 GB9877.1-88 GB5787-86 186F-01019 GB5787-86 186F-01021 GB290-89Qty.1111112222221111421112232(2)Cylinder Head AssemblyRef No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25Part No.186F-02014186F-02202186F- 02003186F-02004186F-02015GBl19-86186F-02007186F-02019186F-02005186F- 02002186F-02008GB6177-88186F-02017186F-02012186F-02006186F-02013186F-02001GB6177-88186F-02009186F-02018186F-02011GB900-88GB900-88GB5787-86GB899-88DescriptionAir Intake Gasket Cylinder Head Intake Valve Exhaust Valve Exhaust Gasket Pin B4 x 8WasherValve duct Seal Valve SpringValve Spring Retainer Valve Screw Nut M6Rocker Arm ScrewExhaust Valve Rocker Arm Rocker Arm SupportIntake Valve Rocker Arm Cotter Nut M6Nozzle Retainer Spacer Washer SpacerStudAM6 x 50 Stud AM6 x 75 Bolt AM6 x 25 Stud AM8 x 20Qty.l 1111111111212111123211(3)Cyl. Head Bonnet AssemblyRef No. 1 2 3 4 5 6 7 8 9 10 11 12 13186FG 1 2 3 4 5 6 7 8 9 10Part No.GB119-86186F-03001186F-03006186F-03007GB3452.1-92186F-03003186F-03014186F-03015186F-03004GB3452.1-92186F-03100GB5787-86186F-03016186FG-03012186FG-03100186FG- 03011186FG- 03009186FG- 03008GB97.1-85GB5783-86186FG-03013GB3452.1-92GB6170-86Description Pin B3 x 16Cyl. Head Bonnet BallBreather Seat O-Ringl2 x 1.9Bonnet Gasket PinPlunger8Decompression Spring O-Ringl2 x 1.9Decompression Shaft Assem.Blot M6 x 70Oiling Screw PlugDecompression Wire Collar Decompression Shaft Assem Decompression WireOuter Decompression Handle Decompression Handle Suppor Washer6Bolt M6 x 15Outer Decompression Handle Bushin O-Ringl2 x 1.9Nut M6Qty. 11 1 12 1 1(5)Fuel Nozzle AssemblyRef No. 1 2 3 4 5 6 7 8Part No.11.435.127.00311.430.100.24011.430.613.00111.433.120.00011.430.136.00011.433.261.00411.433.172.00111.433.314.009Description Nozzle Holder Assem.Shim Pack Nozzle Spring Spring Retainer Stop Plate PinNozzle Valve Nozzle Case Nut(4)Piston & Connecting Rod AssemblyQty. 1 1 1 1 1 2 2 1 2 1Ref No. 1 2 3 4 5 6 7 8 9 10Part No.186F-04100186F-04001186F-04002186F-04003186F-04004GB893.1-86186F- 04008186F-04007186F-04005186F-04006Description Oil Ring Set First Gas Ring Second Gas Ring Piston Piston Pin Washer 23Rod BoltConnecting Rod Body Crank Pin Bearing Crank Pin BoxQty. 2 1 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 3 1(6)Crank Shaft & Flywheel AssemblyRef No.12345678910111212-11314151617Part No.GB / T276-94186F-05301186F - 05006186F - 05004186F-05007GB93-87186F-05005186F-05203GB1096-79186F-05201186F-05202GB1096-79GB1096-79186F-05101186F-05003186F-05002186F-05001GB5787-86186FG- 05006Description Ball Bearing 6203/P5Balancer Shaft Key Balancer Gear Output End Tighten Stud Washerl0Output End Washer Crank Shaft Timing Gear Key6 x 50Crank Shaft Plunger6Key5 x 12Key5 x 14Flywheel Flywheel Nut Washer Flywheel Nut Starter Pulley Bolt M6 x 12Crank ShaftDescription Air Cleaner Bottom Case Assem.Bolt Wing Nut M6Air Cleaner Element Assem.Air Cleaner Cover Assem.Shockproof Sealing Assem.Nut M8Intake Pipe Air Cleaner Gasket Washer (7)Air Cleaner AssemblyRef No.12345678910Part No.186F-07300186F-07301GB6177-86186F-07100186F-07200186F-07203GB62-88186F-07401186F-07001GB97.1-85Qty. 1 1 3 1 1 2 1 1 1 1Qty. 2 2 1 11Ref No.12345(8)Camshaft AssemblyPart No.186F-0610O 186F- 06003186F- 06002GB 1096-79186F- 06001Description Valve Rod Assem.Valve Tappet Camshaft Timing Gear Key 5 x 12Camshaft(9)Silencer AssemblyQty. 1 6 8 2 2 2 1 2 1 1 1Ref No.12345678186FG123Part No.186F- 08100GB5787-86GB97.1-85GB6170-86GB859-87GB97.1-85 -186F- 08200GB5787-86186FG- 08000GB5783-86GB97.1-85Description Case Welded Assem.Bolt M6 x 8Gasket 6Nut M8Washer8Gasket 8 --Silencer Welded Assem.Bolt M6 ~ 12Silencer Assembly Bolt M8 x 15Washer 8(10)Lube Oil SystemQty. 3 1 1 1 1 1 1 1 1 1 1Ref No.11-12345678910Part No.GB5787-86GB5787-86186F- 09001GB3452.1-92186F-09101186F- 09103186F- 09102GB 119-86186F- 09002GB3452.1-92186F- 09200Description Bolt M6 x 12Bolt H6 x 14Oil Pump Butt Plate O-Ring34.5 x 1.8Inner Rotator Outer Rotator Oil Pump shaft Pin B3 x 16Oil Pump Gear O-Ring25 x 2.4Oil Filter Assem.(11)Fuel Tank Fuel Pipe AssemblyQty. 1 1 1 4 2 1 1 1 1 1 1 2 2 1 1 2 1 1 1!. 1 1 1 1 1 1 1 4 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 3 3Ref No.123456789101112131415161718192021222324186FG1234567891011121314151617181920Part No.GB5787-86186F- 10003186F- 10001186F- 10002186F- 10013186F- 10012186F- 10005186F- 10006186F- 10008GB5786-86186F- 10600GB5787-86GB6177-86186F- 10400GB3452-92186F- 10011186F- 10009186F- 10007186F- 10300186F- 10500186F- 10200186F- 10004186F- 10102186F- 10100186FG- 10003186FG- 10200186FG- 10004186FG- 10011186FG- 10012186FG- 10607GB97.1-85186FG- 10601GB869-76186FG- 10602186FG- 1060:GB869-76186FG- 10604186FG- 10606186FG- 10605186FG- 10001186FG- 10002186FG- 10100GB97.1-85GB5786-86Description BoltM8 x 50Bolt Upper Stay Damper Clamp Fuel Oil Retum Pipe Clamp Gauge Pipe washer BoltMl2 x 1.25x 14Lower Stay Assem.BoltM6 ~ 14Nut M6Fuel Tank CockAssem.O-Ringl3.2 x 1.8Clamp Fuel Oil Pipe Fuel Oil Filter Gasket Filter Element Assem.Fuel Injection Pipe Assem Fuel Tank Welded Assem.Fuel Oil Filter Gasket Fuel Tank Cap Assem.Adjusting Hole Cover Fuel Tank Welded Assem.Fuel Tank Damper Connecting Plate Connecting Plate Gasket Circlip Washer 2Floater Rivet 3 x 5Swing Bar Fuel Indicator Rivet 2.5 x 24Pointer Support Sealing Bush Pointer Window Support Filter Cup Filter Cup Supporting Ring Fuel Tank Cap Assem.Washer 5Bolt M5 x 14Description Delivery Holder Delivery Spring Delivery Seal Gasket Delivery Valve Core Delivery Seat Joint O-Ring F.I. Pump Body Plunger Shim Set Pin2 x 6 Packing 0il Control Muff Welded Assem. Steel Wire Retainer Pin3 x 8 Spring Seat Plug Spring Spring Seat Tappet (12)Fuel Injection Pump AssemblyRef No.12345678910111213141516171819Part No.11.413.372.00111.414. 628.00111.410.100.00511.418.502.10811.418.600.20311.413.373.00111.400 .210.00411.415.101.001 11.418.205. 501 11.410.050.001 GB879-86 11. 415 .700.004 11.410.326.003 11.410.224.001 GB879-86 11.410.506.001 11.414.633.001 11.410.330.003 11. 418.731.001Qty. 1 1 1 1 1 1 1 1 1 2 1 1 1 1 2 1 1 1(13)Governor & Control SystemQty.1111111211111221112211211111111111Rcf No.123456789101112131415161718192021186FG12345678910111213Part No.186F-11311186F- 11006186F-11312186F-11401186F- 11301GB5787-86GB5787-86GB6172-86186F- 11403186F- 11402186F- 11005186F- 11007186F-11100GBl17-86 186F- 11003 186FG-11008 186F-11102 186F- 11004 186F- 11001 186F- 11002 186F-11101 186FG- 11303 186FG- 11302 186FG-11012 186FG-11005 186FG- 11307 GB97.1-85 GB5783-86 GB5782-86 GB6173-86 186FG- 11306 186FG- 11305 186FG- 11302 186FG-11301Descnption Control Handle Return Spring 1I Pull Rod Head Handle Bracket Handle Bolt M6 ~ 14Bolt M6 x 18Nut M6Pull Bolt High Speed Limit Screw Return Spring I Governor Spring Lever Fork Part Pin B3 x 22 Washer Lever Shaft Oil Seal Lever shaft Tappet Speed Regulator Fly Block Fly Block Pin Lever Fork Handle Shaft Handle shaft Gasket Governor Spring Return Spring High Speed Limit Screw Washer6 Bolt M6 x 12 Bolt M6 x 45 Nut M10 x 1.25 Bowl Cap Spring Handle Bracket Handle(14)Reeoil Starter Assembly(15)Cooling Device AssemblyQty. 1 1 4 4 5 5Ref No.123456Part No.186F- 17003186F- 17100186F- 17002186F- 17001GB96-85GB5787-86Description Shock Absorber Seat Fan Case Welded Assem Shock Absorber Bush Bush Washer 6Bolt M6 x 22Qty. 1 1 1 1 1 2 2 1 1 1 1 1 4Ref No.1234566-1789101112Part No.GB6170-86GB93-87186F- 14002186F- 14004186F- 14011186F- 14008186F- 14001-01186F- 14001186F - 14006186F- 14007186F- 14005186F- 14100GB5787-86Description Nut M8Washer 8Friction Plate Starter Ratchet Gland Return Spring Starter Katchet Starter Ratchet Axle Reel Spiral Spring Starter Handle Starter Rope Case Assem.Bolt M6 x 12APPENDIX 4.Malfunction and remedy of diesel engine 4-1sLimited WarrantyAMICO provides a one-year limited warranty for AMICO generators. All products covered by this limited warranty which are used in commercial applications are warranted to be free of defects in material and workmanship for 90 days from the date of original purchase. AMICO warrants to the original purchaser that the alternator and engine for its portable generator will be free from the defects in materials or workmanship for the items and period set forth below from the date of original purchase.During warranty period, AMICO will repair or replace any part that, upon examination by AMICO, is found to be defective under normal use and service. Starting batteries are not warranted by AMICO. All transportation cost under warranty including return to the factory if necessary, are to be prepaid by the purchaser. All decisions of AMICO with regard to this limited warranty shall be final.This warranty does not cover:1.Merchandise sold as reconditioned, used as rental equipment, or floor or display models.2.Merchandise that has become damaged or inoperative because of ordinary wear, misuse, cold, heat, rain, excessive humidity, freeze damage, use of improper chemicals, negligence, accident, over loading, over speeding, improper maintenance, the use of accessories or attachments not recommended by AMICO, or unauthorized repair or alterations.3.Expendable parts or accessories supplied with the product which are expected to become inoperative or unusable after a reasonable period of use.4.Any incidental, indirect or consequential loss, damage, or expense thatmay result from any defects, failure or malfunction of the products is not covered by this warranty.For service, please e-mail to or fax to 562-908-1899, Warranty service can be performed only by AMICO authorized service facility. This warranty will not apply to service at any other facility. At the time of requesting warranty service, evidence of original purchase date must be presented.PRODUCT REGISTRATION CARDFor more efficient customer service, please fill out the information below and mail to our produce Warranty and Registration Division:Amico International Corp.4825 Gregg Road,Pico Rivera, CA 90660, U.S.ATel: 562-908-0088 Fax: 562-908-1899Website: Model No.Engine Serial No.Purchase Date. / / Purchased from:[ ] Retail location [ ] Private Consumer [ ] OtherNameAddressTelephone w/area code Purchase PricePurchased: [ ] NEW or [ ] USEDConsumer information :Name Telephone w/area codeAddress Suite or Apt No.City State Zip CodeCountryAre you a: [ ] Business or [ ] ResidenceProduct Usage Information :How often will you use this product?[ ] Everyday [ ] Periodically[ ] Emergency use only [ ]OtherWhat type of application will you use this produce in ?[ ]Heavy Commercial [ ]Moderate Commercial[ ]Light Commercial [ ] Tradeshows[ ] Heavy residential [ ] Moderate Residential[ ]Light Residential [ ]Camping, backpacking[ ]OtherIMPORTANT I NFORIJAT I ONIt is critical to your warranty that the original point of sales receipt be retained by current consumer, and in order to comply with our product Warranty Statement you must return this registration card within 15 days of original purchase. Product warranty is valid from original date of purchase.List for comments from usersDate of ManufactureModel Number Name of userOccupation Address of userPlace of purchasePackaging conditionsOperating conditionsParts ConditionsMalfunction problemOpinions or suggestionsNote: Please mail the above card to:Amico International Corp.4825 Gregg Road,Pico Rivera, CA 90660, U.S.ATel: 562-908-0088 Fax: 562-908-1899Website: 。

技术支持指南型号 2596 自动自清洗过滤器永久介质系统说明书

技术支持指南型号 2596 自动自清洗过滤器永久介质系统说明书

Technical Support Guide Permanent Media SystemsE aton’s filtration business is a global leader in manufacturing filtrationproducts that include automatic self-cleaning and fabricatedpipeline strainers, mechanically cleaned filters and strainers, bag, cartridge and depth sheet filtration systems, hydraulic and lubrication oil filtration and gas/liquid separators for industrial customers worldwide. Eaton has engineering and research and development centers in the USA, Belgium, Germany and China. Sales and service centers are located in 11 countries.Eaton supplies high-quality systems, parts and services to markets that include automotive, food and beverage, ethanol and biofuels, oil and gas, pharmaceutical, power generation, pulp and paper, chemical, paints and coatings, electronics, iron and steel manufacturing, marine and municipal and industrial water. Eaton is well positioned in key markets and is expanding its global footprint with initiatives in the Americas, EMEA and Asia Pacific.Eaton’s filtration business has led the way with technologythat meets the growing and rigorous demands of vital industrial sectors. Utilizing a variety of filtration technologies, Eaton has consistently implemented the best solutions available while continually striving to make a difference for customers andthe environment. Eaton filtration services• State-of-the-art water testing lab facility• Long-term or short-term equipment rental• Field service-inspections, start-up, maintenance, repair and replacement• Field trials• Extensive network of manufacturer representatives and distributors worldwide• Worldwide technical support in international markets• Team of product specialists dedicated to providingapplication engineeringEaton technologies• Customized and modular solutions provide a full range of retention capabilities and construction materials in manualand automated designs• ISO 9001:2015 quality management• Standard ASME “U”, “UM” Code and CRN Stamp• “N” stamp available• European standards - DIN/PED• EPA compliant solutions• Properly sized components to meet any specified flow rate and retention requirement• NSF approved coatings• Ultra low discharge strainer technology that offers reduced purge volumesEaton sustainability commitmentEaton is unwavering in our commitment to being sustainableby design—in the way we operate, through the design of our products and through the energy and climate saving benefits our products deliver. Eaton issues a sustainability report aspart of its annual report, available on .Industrial andmunicipal waterEaton strainers remove debris from lakes, streams andwells that can damage or clog equipment. They also remove leaves, insects, feathers, etc. From cooling tower water where the system is opento the atmosphere. For desalinization equipment, they take out unwanted matter from the water before it is treatedfor salt removal. Spent waste- water often passes througha basket strainer to take out material that should not go into a sewer or a waterway. Process equipmentBy installing an automaticself-cleaning strainer ahead of expensive process equipment, the strainers protect against damage from scale, dirt orby-products, preventing costly shutdowns. Heat exchangers, condensers and pumps use strainers on their intake sides. Automatic self-cleaning strainers keep flow meters andspray nozzles from clogging.Marine industry Automatic self-cleaning strainers are vital in handling seawater, which can contain a good deal of undesirable matter. Cooling lines, fire control lines, sanitary lines and general cleaning lines use strainers. Strainers also clean fuel, hydraulic and lubrication systems. Commercial buildings, hospitals and schools Cooling towers and boilers use automatic self-cleaning strainers to protect them from damage due to scaling. Power generationT he electric power industry uses strainers to clean water for cooling and to protect equipment. They also strain transformer oil to avoid clogging of the circulating lines.More informationFor specific, detailed application information, consult eaton.Content and Product OverviewPermanent Media SystemsModel 2596 Automatic Self-Cleaning StrainersTechnical Support Guide• Introduction, features and benefits • Technical information• How it works – Backwash arm • Flow rate comparison• Control systems and elements•Basic sizing guidlines and design parametersProduct Overview:• Model 2596 2"–8" Cast iron or stainless steel • Model 2596 10"–16" Cast ductile iron• Model 2596 2"–36" Fabricated carbon steel and stainless steelAutomatic Self-Cleaning StrainersContinuous flow, simplified maintenance Model 2596The Eaton Model 2596 Automatic Self-Cleaning strainer is amotorized strainer designed for the continuous removal of entrained solids from liquid in pipeline systems. This strainer is ideal for applications that demand uninterrupted flow, a majorconsideration in plant operations. Eaton automatic self-cleaning strainers are available in thefollowing pipe sizes, 2" to 8" cast iron or stainless steel, 10" to 16" cast ductile iron only, 2" to 36" and special or bigger sizes upon request, fabricated carbon steel and stainless steel. Customdesigns and exotic materials are available upon request. A wide range of screen designs are offered from 1⁄8" perforation to 200 mesh.They are used for strainingcooling water from ponds, lakes or rivers, cooling towers, plant service water, boiler feed water, secondary effluent, irrigation and municipal water intake for equipment protection.The determining factors are the level of solids contentand the ability to handle the backwash discharge flow. Theyare a worthwhile investment when loading is high or upset conditions occur.These strainers also provideworry-free operation. Continuous flow is assured, even while the system is being backwashed, providing uninterrupted protection fornozzles, pumps, valves, heat exchangers and other process equipment.Frequent cleaning and servicing of manual strainers is costly, and if not properly done, serious disruptions to the entire piping system can occur. Eatonautomatic self-cleaning strainers will significantly reduce these maintenance costs. They are ideal replacements for either simplex or duplex manual strainers.Model 2596 - T • Automatic self-cleaning strainers are used to strain fresh, brackish or salt intake water for plant services such ascooling, process and fire protection. The strainers allow water to be recycled within the plant, reducing costs.• Process Industry—Protect heat exchangers, pumps, valves and spray nozzles. • Power Industry—Pump seal protection and cooling water. • Pulp and Paper Industry—Remove and separate bark and chips for recycling and prevent clogging of nozzles. • Sewage and Water Treatment Plants—Strain secondary effluent prior to discharge and provide clean plant service water. • Primary Metal Industry—Provide clean water for quenching, descaling and blast furnace cooling.Cenpeller™ technologyA common problem in many automatic self-cleaning strainers is inefficient backwashing due to debris lodged in the strainer element.The Model 2596 2" to 8" strainer features a vane plate positioned at the inlet of the strainer element where it contacts the process media before it enters the element. The vane plate causes the incoming liquid to move in a circular motion forcing the debris to lay up against the surface of the strainer element rather than lodging in the element’s openings. Lodged debris can negatively impact the differential pressure across the strainer, resulting in a shut down of the strainer and manual cleaning of the element. Cenpeller T echnology helps prevent this situation and delivers easier and more efficient backwashing.• Quality construction: Eaton Automatic Self-Cleaning Strainers are designed and constructed in accordance with”AD 2000-Merkblätter“, DIN EN 13445 or ASME Code. ASME code stamp and approval according to PED 97/23/EU (modules H, H1 orG) are available. Seismic qualification is also available.• Idl TM seal:The unique eaton idl Shaft Seal prevents troublesome leakage. This special quad seal means that the strainer always stays dry and clean in service with no process media leaking down the sides of the strainer.• Ease of maintenance: Unitized modular assembly—the motor, gear reducer, cover and complete internal operating mechanism lift off as a unit, making all components easily accessible. This greatly simplifies maintenance and reduces costs.• Low backwash fluid requirements: Only a small portion of system flow is used during backwash due tothe efficient hydraulic design.• Choice of screen elements: DuraWedge perforated or mesh elements.• Minimal power consumption:1�4HP drive motor in 2" through 16", 1�3HP in 18" through 24", ½ HP in 30", 1 HP in 36" through 42"and 2 HP in 48" strainers.• No bypass of contaminants: 2" to 8" element caps are epoxy sealed to screen media. O-ring seals on body cover prevent bypass around element. 10" to 36" (special and bigger sizes upon request) element caps are epoxy sealed to screen media. A machined cover and body provide metal-to-metal sealing and prevents bypassaround the element. For those elements whose retention is below 300 micron (60 mesh) an elastomer seal is provided on top andbottom of the element.• Cover seat design: O-ring permits resealing without time-consuming gasket replacements and adjustment.• Manual operation if required: utilizing extended shaft.For coarse straining applications, such as raw water intakes from lakes, ponds and streams, the convoluted perforated elements will perform well and offer the most economical unit pricing.On applications in which pre-screening of the fluid has been performed, but finer filtering of the fluids is desired, thesinter-bonded mesh element may be selected.On applications in which the fluid being strained encounters fibrous materials, the DuraWedge element will minimize the impact of the fibers stapling to the screen.Debris: Cleaning the straining element is accomplished by usingthe pressure differential between line pressure and atmosphere. During the cleaning cycle, when the backwash valve is opened to atmosphere, a portion of the strained fluid reverses flow back across the isolated section of element, lifts off the debris and ejects it out of the strainer.Sticky or greasy debris are more difficult to backwash and may require longer backwash cycle durations. Sand, dirt and pipe scale should backwash easily. The quantity of debris coming into the strainer also can be a problem. Ensure that the volume of the suspended solids does not exceed 200 ppm or 0.02%. If the application requires heavier loading consult Eaton.Backwash requirements:The quantity of fluid requiredto clean a straining element is dependent upon the type and quantity of debris. Under normal conditions, approximately 5% of the line flow will be used for cleaning of the straining element during the cleaning cycle. To minimize the loss of fluid through the backwash, Eaton recommends to add a manual throttling valve downstream of the automated valve.Pressure and temperature• Cast Iron is rated at 13.8 bar @ 65°C.• Ductile Iron is rated at 10.3 bar @ 65°C.• Cast Stainless Steel is rated at 18.9 bar @ 37°C• Fabricated units are rated at 10 bar @ 65°C.However, other ratings are available, consult Eaton.• The minimum operating pressure is 1.4 bar.Inlet of screenelementTop ViewStraining cycleModel 2596 Strainer: How it worksThe debris-laden fluid enters thestrainer’s bottom chamber (1) where the line velocity isreduced. Flow continues upward,passing radially through thesealed screen element (2), which traps debris on the inside of the screen. The flow is uninterrupted and the strained fluid flows to the outer annulus (3) and exits through the outlet nozzle (4).Backwash cleaning isaccomplished by utilizing thepressure differential between line pressure and atmosphere. A high-efficiency, full flow backwash arm (5) extending the entire length of the screen element, rotatesslowly inside of the screen and is piped to atmosphere. The port shoe (6) is in proximity to the screen and its opening is equivalent to the “debriscollector” sections created by the convolutions and/or vertical collector bars in the element.When cleaning is required the automatic backwash valve opens the system to atmosphere, causing a high velocity reverse flow across the isolated section of the screen. Dirt and debris are dislodged from this segment of the screen into the backwash arm and out the strainer through the backwash piping (7). During the backwashing cycle the main flow is uninterrupted andcontinues to be strained in the normal manner.Designed to monitor and operate the backwash cleaning system, Eaton automatic control systems are simple to operate, reliable andBackwashing cycleDuring backwashing, only a small portion of the screen is cleaned at any given time. The majority of the screen continues to screen as normal.Mechanically Cleaned Filters & Strainer TECHNICAL INFORMATIONModel 2596 Automatic Self-Cleaning StrainersBackwash Armeasily maintained. They are set to clean on differential pressure with a timed backup. The design allows field adjustments to suit the demands of the serviceconditions, ensuring effective cleaning with a minimum use of backwash fluid. Systems areavailable in automatic, intermittent or continuous backwashing modes.Top ViewV-Shaped Profile WireStrained Clean Continuous FlowDuraWedge Screen Element Reinforcing Bands Debris-Laden Flow from InletBackwash Arm Opened to AtmosphereStrained Clean Continuous FlowReverse FlowReverse FlowDirty Fluid Discharged through Backwash PipingStrained Continuous FlowCollector BarsPort shoe on backwash arm matches “debris collector section” on screen.Backwash Arm Rotates around the Screen to Clean every Section over Time.BackwashArm Closed to AtmosphereStrainedContinuous FlowDebris-Laden Flow from InletDebris-Laden Flow from Inlet1234567Model 2596 flow ratecomparison chartI/OFlow rate**Size & construction* m 3/h 2" cast 11.4–27.33" cast 22.7–59.1 4"/4L" cast 38.6–102.2 6" cast 84–227.1 8" cast 113.6–408.8 10" cast 204.4–635.9 12" cast 272.5–908.5 14" cast 363.4–1,135.6 16" cast 454.2–1,476.3 2" fabricated 11.4–27.3 3" fabricated 22.7–59.1 4"/4L" fabricated 38.6–102.2 6" fabricated 84–227.1 8" fabricated 113.6–408.810" fabricated 204.4–635.9 12" fabricated 272.5–908.5 16" fabricated 454.2–1,476.3 18" fabricated 567.8–1,930.6 20" fabricated 658.7–2,316.7 24" fabricated 726.8–3,406.9 30" fabricated 1,135.6–5,45136" fabricated1,771.6–7,949.4* Special and bigger sizes upon request.** P ressure drop data is approximate and indicates results to be expected with clean water, under normal flows with standard screens and in clean strainer. For DuraWedge and sinter bonded elements, consult Eaton.Sizes 2" to 8"Cast Construction Model 2596 Automatic Self-Cleaning PipelineStrainers are available for six different pipeline sizes. The 4L" size is designed for applications where the combination of flow rate and open area requirements may be too great for astandard 4" size. Flow rates up to 409 m³/h.Model 2596 10" to 16" Cast Metal models provide flow rates up to 1,476 m³/h.Model 2596 Fabricated models are available in 13 different sizes from 2" to 36" (special and bigger sizes can be fabricated upon request). Custom designs and exotic materials are also available upon request, consult Eaton.The Eaton Easy 719 Control Unit is housed in a Rittal control box with IP65 protection. The control supply voltage is 400 V 3 Ph50 Hz, meaning the motor can be supplied with the same ing transformers, the control system can supply three different output voltages for the backwash valve. The available options are 24 V , 110 V and 230 V .In addition to the standardsystem described above, other models can be supplied to meet special requirements relating to wiring, control boxes (door locking system) or ATEX, for example.Eaton’s Automatic Control Systems are specifically designed to monitor and control the backwash system of automatic self-cleaning strainers. They are both reliable and easy to use. They make it possible to make adjustments that take operating conditions into account and guarantee effective cleaning with minimal use of backwashing fluid.Standard Control System FeaturesModes of OperationComponentsThe Eaton Easy 719 control relayenables fully-automatic operation. In the automatic intermittent mode, rinse intervals and cycle length can be configured via an external display. The backwash valve can also be controlled manually using a push button.In both automatic mode and manual backwash mode, the backwash arm continuously rotates at a low 2–4 RPM.The automatic intermittent mode can be configured using the Eaton Easy 719 display panel. Adjustable timers control the frequency and duration of backwashing. On-siteadjustments are necessary in order to configure this mode to precise usage requirements.Furthermore, differential pressure switches in the inlet and outlet can be configured so thatbackwashing will be initiated if differential pressure rises above the chosen setting.MotorsAn electric motor and gear box are supplied with the strainer. The standard motor is a three-phase 400 V/50 Hz motor.Additional motors are available upon request.Differential pressure switch The control system can optionally be fitted with pressure switches in the filter inlet and outlet. The additionally activated differential pressure mode compensates for sudden high dirt loading byoverriding the time cycle initially set and initiating backwashing before the end of the cycle. This secondary protective function prevents element damage.Backwash valveThe strainers can be equipped with electrically actuated ball valves (24 VAC, 110 VAC or 230 VAC). The construction materials used are suitable for water applications. Other materials, valve types and pneumatic actuation are optional.Backwash valve sizes Valve size2", 3", 4" 1"6", 8"1 ½" 10", 12", 14", 16" 2" 18", 20", 24", 30" 3" 36"6"Special and bigger sizes upon requestControl Systems & ElementsDuraWedge® ElementThe nonclogging and rugged DuraWedge element is made ofstainless steel, formed with precision V-shaped profile wire. Available only from Eaton.• T wo point contact straining from the “smooth” side prevents plugging or packing of debris and particles.• E ffective dislodging of dirt, debris and fibers from the element during backwash. This is accomplished by the increased velocity of the reverse flow (during backwash) from the “open side”.• F iber stapling is reduced because of smooth surfaces and the design contour of the profile wire.• V ertical collector bars form spaces to accumulate debris and dirt, preventing snow plowing of materials by the rotating backwash arm and port shoe.• No bypass. Elements are sealed.• F ully-welded design with circumferential reinforcing bands provides structural integrity. DuraWedge Element Selection2", 3", 4", 6", 8" 1⁄16", 1⁄32", 0.015"10", 12", 14", 16" 1⁄8", 1⁄16", 1⁄32", 0.015", 0.009" 18", 20", 24"3⁄16", 1⁄8", 1⁄16", 1⁄32", 0.015", 0.009"Eaton offers a full range of element choices for automatic strainers. All are manufactured to the toughest industry standards and are designed for long term use in even the most demanding applications.Convoluted ElementThis is a sturdy, economical stainless steel element for general service use. It is ideal in applications where leaves, twigs and large amounts of miscellaneous debris are encountered. The generous spaces created by the convolutions provide an area for the debris to collect. “Packing” does not occur due to the gradual contoured shape of the convolutions. During backwashing the debris is easily dislodged and carried away through the backwash arm and out of the strainer.Features• C ircumferential reinforcing bands for added resistance to pressure and flexing ensures long service life.• Cartridge design for easy removal and cleaning.• C onvoluted sections are individually isolated by the port shoe during backwash for increased cleaning efficiency.• N o snow plowing. Convoluted profile provides collection spaces for debris.• Extended area design offered only by Eaton.• No bypass.• Sinter bonded mesh available - An Eaton exclusive. Convoluted Element SelectionStrainer SizeStandard OpeningsConvoluted perforated element 2", 3", 4", 6", 8" 1⁄8", 1⁄16", 1⁄32" 10", 12", 14", 16" 1⁄8", 1⁄16", 1⁄32" 18", 20", 24"5⁄32", 1⁄8", 1⁄16"Convoluted mesh element All sizes20 mesh (0.015") to 200 mesh (0.003")Basic Sizing Guidelines1. E nsure that the pipeline flow velocity falls within thestandard design range of the strainer.2. S elect the correct screen and opening size, do not make smaller than necessary.3. T he quantity, type and nature of debris to be removed are considered.4. T he strainer meets the design pressure and temperature requirements of the pipeline.5. B ackwash line should discharge to atmosphere in close proximity to the strainer.Standard Design Parameters1. S elf-cleaning strainers have a design flow range where the unit will best perform its two main functions, straining and self-cleaning.2. I nlet flow velocity to the strainer should be in the 1.83 to3.05 m/s range. There may be applications where the operating flow will fall outside the normal design range. When this occurs, please contact Eaton for recommendations.3. M inimum operating pressure is 1.38 bar for standard units. Consult Eaton for equipment options when the system pressure is less than 1.38 bar.4. S uspended solids should not exceed 200 ppm or 0.02% of volume (see below). For heavier loadings consult Eaton.Strainer sizing chart **Special and bigger sizes upon requestPPM %1,000 GALSuspended solids sizing chart and conversion table3STANDARD DESIGN RANGEVelocity [m/s]2.02.53.0Velocity [ft/s]F l o w r a t e (w a t e r ) [G P M ]22,50013,5009,0004,5002,2501,8001,3509004502251801359045231813.594.520406080101002006008001,0002,0004,0006,0008,00010,00020,00040,00060,00080,000100,000400F l o w r a t e (w a t e r ) [m ³/h ]For more information, please email us at ********************or visit /filtration© 2022 Eaton. All rights reserved. All trademarks and registered trademarks are the property of their respective owners. All information and recommenda-tions appearing in this brochure concerning the use of products described herein are based on tests believed to be reliable. However, it is the user’s responsibility to determine the suitability for his own use of such products. Since the actual use by others is beyond our control, no guarantee, expressed or implied, is made by Eaton as to the effects of such use or the results to be obtained. Eaton assumes no liability arising out of the use by others of such products. Nor is the infor-mation herein to be construed as absolutely complete, since additional information may be necessary or desirable when particular or exceptional conditions or circumstances exist or because of applicable laws or government regulations.North America 44 Apple StreetTinton Falls, NJ 07724Toll Free: 800 656-3344 (North America only)Tel: +1 732 212-4700Europe/Africa/Middle East Auf der Heide 253947 Nettersheim, Germany Tel: +49 2486 809-0Friedensstraße 4168804 Altlußheim, Germany Tel: +49 6205 2094-0An den Nahewiesen 2455450 Langenlonsheim, Germany Tel: +49 6704 204-0Greater China No. 7, Lane 280, Linhong RoadChangning District, 200335 Shanghai, P .R. China Tel: +86 21 5200-0099Asia-Pacific100G Pasir Panjang Road #07-08 Interlocal Centre Singapore 118523Tel: +65 6825-1668Volume conversion factorsPressure Conversion FactorFlow velocity conversion factorsVelocity = GPM X 0.4085 in ft/s ____________ID 2in inchesStrainer Basket Opening EquivalentsTighter retentions available, consult Eaton.Strainer Basket Opening EquivalentsEN 05-2022。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

CSR-2060微机通讯管理装置使用说明书杭州华光电气有限公司二零零六年目录1 适用范围 (1)2 功能介绍 (1)3 技术参数 (1)3.1 通信口 (1)3.2 数据库容量 (1)3.3 传送数据指标 (1)3.4 所有通信口光电隔离 (1)4 数据库简介 (1)5装置菜单操作说明 (2)5.1主菜单结构及内容 (2)5.2操作说明 (2)附图1.CSR-2060微机通讯管理装置背板端子图 (11)附图2.CSR-2060微机通讯管理装置原理框图 (12)1 适用范围CSR-2060微机通讯管理装置适用于厂站自动化系统所有智能设备之间相互通信,对全站自动化信息进行整理归纳,负责站内外的信息交换及设备控制,可在线实现多种通信协议转换。

2 功能介绍CSR-2060微机通讯管理装置是HE2000系列保护控制自动化系统的通信枢纽,协调HE2000间隔设备的数据、命令交换,收集厂站不同类型的实时数据,以不同规约、不同的通信媒介向调度/集控站转发,同时也接收来自调度/集控站的下行命令,转发至各间隔设备单元。

●收集HE2000系统各间隔单元的数据信息并转发至主控端;●收集主控端控制命令,转送至相应间隔单元设备;●监视各间隔的运行状态,发现异常及时告警;●可支持RS232/RS422/RS485及CAN网口等接口同智能设备连接;●通信速率可在线设定;●支持远方在线参数设定;●通信协议可由用户指定;3 技术参数3.1 通信口设有10个串行口:同/异步、奇/偶校验、规约在线选择、通信速率300—9600波特可选,其中04,05,08,09号口可通过软件设置成RS485串行口;1个CAN网口:通信速率125k波特率,最大挂110个节点。

3.2 数据库容量遥测≤2048遥信≤1024遥脉≤1024遥控≤2563.3 传送数据指标遥信变位≤1s遥测变化≤1s遥控返校≤2s重要遥测更新≤3S全部数据刷新≤10s3.4 所有通信口光电隔离4 数据库简介通信管理机的数据库大致有以下四种:Y C – D A T A B A S E [1024] w o r d 遥测Y X – D A T A B A S E [2048] b y t e 遥信D D – D A T A B A SE [1024] w o r d 遥脉Y K – D A T A B A S E [256] b I t 遥控当地厂站内,按线路的概念将数据库划分如下:a、DATABASE[2048]每16个为1条线路,亦即每一线路的模拟量从16的倍数处开始存放。

b、YX-DATABASE[1024]每8个YX为1条线路,亦即每一线路的遥信量从8的倍数处开始存放。

c、YM-DATABASE[1024]每4个YM为1条线路,亦即每一线路的遥脉从4的倍数处开始存放。

d、每条线路占一个YK号。

5装置菜单操作说明5.1主菜单结构及内容命令菜单为树形结构多级菜单,在“开机屏幕”状态下,按除复位键外任意键即可进入“主菜单”,在“主菜单”下,按“取消”键即可回到“开机屏幕”状态,按“确认”键可进入下一级菜单,按“取消”键返回上一级菜单。

对一般的屏幕“▼”“▲”“◄”“►”键为光标调整,对可以修改的数据用“╋”“━”键对数据进行修改,并把相应的数值写入存储器中。

对于选择菜单,当光标移到指定位置后,按“确认”键即可进入将要选择的项目中。

5.2操作说明5.2.1参数设置5.2.1.1设置ISO说明如下:a、pass :数据确认密码“0000”,按“确认”键后,此位置将显示“SAVE OK!”,表示设置成功。

b、Port_Num : 表示现在设置的串行口号(0~9);c、ZF_Table : 指转发表,共计5个转发表(0~4);d、File :指转发文件类型,即规约。

一般有:DISA_ZF : 通信机转发至当地后台的规约NewBBZF : 部颁规约Setpara : 后台参数设置No : 未定义LFP : 南瑞LFP_规约COMM_DD : 智能电表COMM_DC : 智能直流屏COMM_TD : 智能接地选线装置GPS : 天文时钟SD_WF : 南瑞系统室的五防闭锁装置SC1801 : 1801规约DCF5 : 山东DCF5规约IEC101 : IEC60870-5-101U4F : U4F规约;e、 A/Sync : 设定串行口异/同步方式:Asyn为异步方式,Sync为同步方式。

f、 Parity : No:设定串行口校验为无校验;Even_为偶校验;ODD_为奇校验;g、 Link :设定串行口的运行方式,RS232、RS485两种方式可选;h、BaudRate :波特率设置,300~9600可选;5.2.1.2设置CPU说明如下:a、PASS:为设置确认的密码:0000;b、Total:单元装置数目;c、No:当前设置的单元装置号,如单元装置数量为N个,则No为0~N-1;d、Type:当前设置的CPU的类型,未作规定,一般取1;e、Ad:当前设置的CPU的地址(1―254),与各单元装置地址相对应;f、Relay:当前设置的CPU类型,未作规定,填001;g、Lc:当前设置的CPU所接的通信口,CAN口为010,其它与各串行口相对应;h、YCFrm: YC:指CPU上传的YC数据将放在YC-database[Ycfrm]到YC-database[YCFrm+YC-1]中;i、YmFrm:YM: 指该CPU上传的YM数据将放在YM-database[Ymfrm]到YM-database[YmFrm+YM-1]中;j、DDFrm:DD: 指该CPU上传的DD数据将放在DD-database[DDFrm]到DD-database[DDFrm+DD-1]中;k、Ykfrm:YK: 指该CPU上传的YK数据将放在YK-database[Ykfrm]到YK-database[YkFrm+YK-1]中;注:一次只能设置一个CPU,一个设置完成需确认保存,然后再设置另一个。

5.2.1.3设置保护地址说明如下:Relay_L:保护数目0—E:为保护数目序号00:为保护地址号。

5.2.1.4设置系统时间说明如下:用“▼”“▲”“◄”“►”键对光标进行调整,对可以修改的数据用“╋”“━”键对数据进行修改,并按“确认”键即可。

5.2.1.5设置其他参数说明如下:RTU Addr:本装置地址号Time Port:本装置对时口CAN-Baud :CAN通讯速率设置YCYXClear:本装置断电再上电时遥测、遥信信号清零设置EventDrv :本装置产生事故总信号RLY_Panel:取保护定值1roud ACT:小电流接地选线动作类型代码Gnd False:小电流接地选线故障类型代码。

5.2.1.6设置EEP说明如下:此菜单由程序员用,用户不能使用。

5.2.1.7设置遥测转发说明如下:a、Tab:表示选择的遥测转发表,0~4可选。

该转发表号意义同前面串行口设置的转发表号意义相同;b、CLR:对当前显示的遥测号不转发;SET:对当前显示的遥测号全转发;设置结束后需按确认键保存。

c、YC0000:当前页遥测起始号;d、每屏显示6组,每组有16个模拟量组成,FUUUVVuiIIIPQChh分别表示为:频率、Ua、Ub、Uc、Uab、Uca、U0、I0、Ia、Ib、Ic、有功、无功、功率因数、备用、备用。

A:设为重要遥测转发、B: 设为一般遥测转发、C: 设为次要遥测转发;按“▼”键翻页;e、每一转发表在设置完后需先按“确认”键保存,中途更换转发表号时,先前的设置将作废;5.2.1.8设置遥信转发说明如下:a、Tab:表示选择的遥信转发表,0~4可选。

该转发表号意义同前面串行口设置的转发表号意义相同;b、CLR:对当前显示的遥信号不转发;SET:对当前显示的遥信号全转发;设置结束后需按“确认”键保存。

c、YX0000:当前页遥信起始号;d、每屏显示6组,每组有16个遥信量组成,0~F分别表示为:对应装置的0~15路遥信。

Y:转发、N: 不转发;按“▼”键翻页。

e、每一转发表在设置完后需先按“确认”键保存,中途更换转发表号时,先前的设置将作废;5.2.1.9设置遥脉转发说明如下:a、Tab:表示选择的遥脉转发表,0~4可选。

该转发表号意义同前面串行口设置的转发表号意义相同;b、CLR:对当前显示的遥脉号不转发;SET:对当前显示的遥脉号全转发;设置结束后需按确认键保存。

c、DD0000:当前页遥脉起始号;d、每屏显示6组,每组有16个电度量组成,0~F分别表示为:对应电度的0~15路遥脉。

Y:转发、N: 不转发;按“▼”键翻页。

e、每一转发表在设置完后需先按“确认”键保存,中途更换转发表号时,先前的设置将作废;5.2.1.10设置表4转发说明如下:a、每屏显示6组,每组YC:遥测转发, YX:遥信转发, DD:遥脉转发;000表示要设置的转发序号。

b、每一转发表在设置完后需先按“确认”键保存,中途更换转发表号时,先前的设置将作废;5.2.1.11设置档位转换说明如下:a、 L:线路号(档位遥信转换为遥测所在的CPU地址);Dev:设备名称(1#主变设为0, 2#主变设为1);YX:档位数.b、每屏显示6组,每组YXN0:档位遥信序号, WeiGHt:档位遥测数, 按“▼”键翻页。

c、每一转发表在设置完后需先按“确认”键保存,中途更换转发表号时,先前的设置将作废;5.2.1.12设置事件遥信说明如下:a、RealayToSoe:需要转换的保护遥信数目;YX:档位数.b、每屏显示6组,每组No: 保护遥信数目的序号, PM:保护地址, PU:保护编号(低压保护为1), ACT:保护动作代码, YX:保护事件转换成遥信所在的遥信序号,按“▼”键翻页。

c、每一转发表在设置完后需先按“确认”键保存,中途更换转发表号时,先前的设置将作废;5.2.1.13说明如下:a、OR-YX:需要转换的遥信数目;b、每屏显示3组,每组有5路遥信或计算, “=”左面为遥信或计算后的结果,按“▼”键翻页.c、每一转发表在设置完后需先按“确认”键保存,中途更换转发表号时,先前的设置将作废;5.2.1.14设置乘系数(此功能已取消)5.2.1.15设置地址表(此功能已取消)5.2.2 数据浏览5.2.2.1 浏览遥测量说明如下:屏幕显示2组,每组有2路遥测量, DOT: 遥测序号, HEX: 遥测值十六进制显示, BCD: 遥测值十进制显示。

5.2.2.2浏览遥信量说明如下:屏幕显示2组,每组有16路遥信量, From: 遥信起始序号, 0--F:分别代表(遥信起始序号+0)--(遥信起始序号+15)路遥信。

相关文档