Ohmic Instruments Company 温湿度传感器说明书

Ohmic Instruments Company 温湿度传感器说明书

740SERIESman.pdf
1
30 OCT 08
T-00 Wall-Mount
1 .65" (42mm)
4.72" (1 20mm)
PG-7
3.15" (80mm) 3.15" (80mm)
2.16 " (5 5mm)
1.14" (29m m) 2 .16" (55mm)
0.79 " (20 mm)
As an alternative to the S-503 humidity generator, reference bottles can be used. However, this method is less accurate and can take up to two hours per point to stabilize. These bottles can be purchased from Ohmic Instruments Co.
Duct-mount, high temperature
RH Transmitter, L = 200mm
HX-740-T-10 HX-741-T-10
Duct-mount, high temperature RH & Temperature Transmitter, L = 200mm HT-740-T-10 HT-741-T-10
Remote
RH & Temperature Transmitter, 7/8” - 14 UNF HT-740-T-04 HT-741-T-04
Remote
RH Transmitter, miniature diam. 8mm HX-740-T-05 HX-741-T-05

疫苗冷链温湿度监测系统设备安装位置及环境要求

疫苗冷链温湿度监测系统设备安装位置及环境要求

附件1:
疫苗冷链温湿度监测系统设备安装位置及环境要求
一、安装位置
1、SIATEMP010F型定点温湿度自动监测仪适用于冷库、冷藏箱等
2、主机安装在冷库或冷藏箱外
3、温湿度探头安装在冷库或冷藏箱内
4、分中心服务器安装在疾控中心的计算机机房内,需要19”标准机柜(有2U以上的空位),以及公网接入和UPS(在线4H,2KVA以上)。

二、安装环境要求
1、主机工作温度范围:-20~60°C
2、主机工作湿度范围:0~100%
3、探头工作温度范围:-40~125°C
4、探头工作湿度范围:0~100%
5、安装区域必须要有手机信号覆盖
6、安装区域需提供外接220V交流电源
附件2:
市疫苗冷库和运输车运行状况调查反馈表
附件3:
2011年江苏省免疫规划疫苗冷库分配表。

宁波江北君荣 ACH606A智能湿度控制器使用手册说明书

宁波江北君荣 ACH606A智能湿度控制器使用手册说明书
JRDZ 8:如出现产品故障,请勿自行维修,如遇任何问题请直接与厂商或代理商联系。
地址:宁波江北倪家堰路 7 号 电话:(0574)87386939 87386839 87386739 网址:
邮编:315021 传真:分机 616 邮箱:jr@
J闪烁,显示值为相对湿度下限值的设定数值。
7:按 + 键,或 – 键,可调节相对湿度下限值的设定值。长按 + 键或 – 键,设定值会连 续增加或减少。相对湿度下限值设定值最小 30%RH,最大为相对湿度上限值。将设定值调整 到自己需要的湿度值。进入下一步。
8:按 SET 键,等到 HOUR 灯闪烁,程序进入定时时间设定。此时 HOUR 灯闪烁,显示值为定时
七、使用注意事项: 1:将控制器安装在适宜的通风环境中,避免阳光直射,远离热源、热风口等。 2:严禁在超过本控制器使用范围使用,否则将发生不可预测的后果。 3:严禁雨淋、潮湿、大量粉尘、机械震动、撞击、以及强电磁辐射等。 4:本控制器为室内使用型,严禁在室外使用。 5:请保持控制器的清洁。 6:本控制器最好垂直安装使用。 7:长期不使用时,请断开控制器电源。
J在设定的相对湿度下限值与设定的相对湿度上限值的范围之内。
4:定时设定为 oFF 时,本控制器只作为一个温湿度显示器使用。无论环境相对湿度是多少都
不会开启加湿机进行加湿。
5:定时设定为 0.1 – 9.9 之间时,表示加湿机将工作的最长时间,也可做为一个时间控制器
使用。
地址:宁波江北倪家堰路 7 号 电话:(0574)87386939 87386839 87386739 网址:
地址:宁波江北倪家堰路 7 号 电话:(0574)87386939 87386839 87386739 网址:

教学文件3-20 常用温湿度传感器型号及参数

教学文件3-20 常用温湿度传感器型号及参数
性能指标: ①湿度敏感元件:进口湿敏电容 ②温度敏感元件:Pt1000 ③供电电压: AC/DC 24V±20% ④输出方式: 电流输出 ⑤使用温度范围:-25~85℃ ⑥温度检测范围:0~50℃ ⑦湿度检测范围:0~100%RH ⑧储存温度范围:-10~40℃ ⑨储存湿度范围:30~70%RH ⑩湿度检测精度:±3%RH (温度23℃,湿度30%--90%) 温度检测精度:±0.3℃ 负载阻抗: ≤500Ω 。
常用温湿度传感器型号及参数
YRF-0063无线温湿度传感器
产品品牌:盈瑞丰wisdom 产品型号: YRF-0063
应用场合: 无线数字温湿度传感器适用于室内外各种环境的温湿度监测,广泛应用于温室大棚、实验室、博物馆、图书 馆、档案馆、生产车间、仓库、机房、楼宇自控等场所。 产品简介: 此款温湿度传感,是集温湿度测量、变送于一体的智能无线产品,能够精确测量环境温湿度。温湿度测量部 分采用专业的数字式传感器,外加传感器专用防护罩,保证了测量数据的可靠性与稳定性。信号传输方式选 择通信距离远、穿透能力强的433MHZ频段信号。多台温湿度传感器与无线协调器可组成温湿度监测、监控系 统。同时,产品自带液晶显示屏,温度值与湿度值可切换显示,方便现场查看温湿度数据。
赛普EFR012电子式湿度控制器
产品品牌:saipwell/赛普 产品型号:EFR012
工作电压 湿度范围
适用范围
110-250(V) 安装形式 35mm导轨式
40-90(%) 重量
0.08kg
用于控制风机、加热器和转换器,也 可以用于监控配电柜内的温度
HTW-IC00X温湿度传感器
产品品牌: GREYLeabharlann ELL 产品型号: HTW-IC00X
工作电压 测量范围

海林自控HL-SO系列温湿度传感使用说明书

海林自控HL-SO系列温湿度传感使用说明书

HL-SO 系列温湿度传感使用说明书应用HL-SO 系列温湿度传感器广泛应用于楼宇自控领域,主要用于室外温度、湿度的测量,可提供多种温度测量范围,可提供NTC 、铂电阻、电压、电流信号输出,可以适应各种控制系统的不同要求。

技术指标:温度测量:准确度:±0.3℃(@25℃) 输出信号:0V ~10V/4mA ~20mA Pt (Pt-1000、Pt-100)NTC (10K 、10K-3、20K 、20K-3) 输出分辨率:0.02V/0.01V/0.032mA 湿度测量:准确度:0~20%RH ±5%RH20~90%RH ±3%RH 90~100%RH ±5%RH输出信号:0V ~10V/4mA ~20mA 输出分辨率:0.02V/0.01V/0.032mA环境温度:-40℃~80℃接线端子:能连接2根1.0mm2或1根1.5mm2的导线 环境湿度:5~95%RH (非凝结) 负载能力:电压≤1mA ;电流≤600Ω 电源电压:24VDC (15V ~ 35V )防护等级:IP53电气连接按传感器内部PCB 板上的字符指示接线。

字符定义如下: V+ —— 电源正极; V - —— 电源负极; H —— 湿度输出; T —— 温度输出;Pt1 —— Pt 电阻单极输出端; Pt2 —— Pt 电阻双极输出端之一;Pt3 —— Pt 电阻双极输出端之二(补偿端)。

接线注意事项:1、传感器湿敏感组件及器件应避免静电,注意不要用手触摸,以防损坏。

2、所有引线应与接线标识相符,并且接线工作只能由专业人员进行。

3、传感器的引线应与高、低电压线路或其它用电设备(接触器、线圈、电机等)的走线分开。

4、推荐采用屏蔽电缆接线以预防干扰,屏蔽层单端接地,通常接控制器的信号地线,不可以接强电的地或者大地,以免引入更多干扰。

5、NTC、铂电阻输出的传感器引线长度不应超过20m ,超过20m时应选用电压、电流输出类型的传感器;电压输出型传感器,引线长度不应超过50m;电流输出型传感器引线长度则可相应延长。

湿敏传感器在各方面的应用

湿敏传感器在各方面的应用

湿敏传感器在各方面的应用【引言】ROTRONIC暖通净化工程用温湿度传感器:罗卓尼克公司自1967年开始研发湿度传感器,产品经过多年来的经验积累和技术改进,已经成为全球领先的湿度测量专家。

产品具有高精度和高可靠性等特点,具有竞争力的价格及灵活的组合式解决方案,深受诸多用户喜爱,在各种场合得以广泛应用。

ROTRONIC全部产品都在瑞士总部进行研发和制造,工厂拥有一流的校准实验室,ISO9001-2000质量认证。

在全球有很多分公司和有丰富经验的代理商。

ROTRONIC自1965年一直致力于温湿度测量产品的研发制造。

为了能在多种应用中,以最具竞争力的价格为客户提供更高精度、更灵活的产品,从传感器进入市场以来,ROTRONIC从未间断过对它的改进,并一直采用最佳质材料和最先进的生产技术。

ROTRONIC 全部产品都在瑞士总部研发制造(ISO9001:2000)。

ROTRONIC公司具备瑞士国家级校准服务SCS实验室(SCS065)和世界顶级的传感器设计专家和团队。

直到今天,在市场上所有可以测量和 200°C环境的湿度传感器中,传感器仍有着最为广泛的应用。

作为具有多年经验的湿度测量专家,ROTRONIC为客户提供最佳性能的OEM产品和最高性价比的温湿度解决方案,同时也为客户提供维修和校准服务。

同时ROTRONIC正为未来的传感器市场份额奋斗、打拼。

【工作原理介绍】一、工作原理湿敏随着时代的发展,科研、农业、暖通、纺织、机房、航空航天、电力等工业部门,越来越需要采用湿度传感器,对产品质量的要求越业越高,对环境温、湿度的控制以及对工业材料水份值的监测与分析都已成为比较普遍的技术条件之一。

湿度传感器产品及湿度测量属于90年代兴起的行业。

如何使用好湿度传感器,如何判断湿度传感器的性能,这对一般用户来讲,仍是一件较为复杂的技术问题。

1 湿度传感器的分类及感湿特点湿度传感器,分为电阻式和电容式两种,产品的基本形式都为在基片涂覆感湿材料形成感湿膜。

开关量温湿度传感器说明书

开关量温湿度传感器说明书

一、应用范围精密型温湿度传感器是采用最新专利技术半导体敏感器件设计方案,用于测量室内环境的温度、湿度的一体化智能监控模块。

产品不仅具有显示直观、精度高、成本低、外形美观、安装方便等特点,而且特别具有专利技术的自恢复自校准功能,因此,产品测量精度高、长期稳定性好。

本公司提供有RS485接口、干节点输出接口、4-20mA模拟输出等多种型号产品,为用户提供全系列温湿度监控解决方案,已经广泛应用于通讯机房、IDC数据机房、空调室、实验室、图书馆、办公室等室内场所的温湿度测量。

二、主要技术参数三、主要特点(1)采用最新专利技术敏感元件,具有自恢复自校正功能,精度高,一致性好;(2)大屏幕高亮度LCD显示,观察直观、操作简便;(3)具有温度单位选择:摄氏度(℃)、华氏度(℉)可设置,可在全球范围使用;(4)具有温度、湿度误差校正设置,方便进行定期校验;(5)具有温度、湿度告警范围设置,提供干接点告警信号输出,实现本地告警功能。

(6)独特风道设计,电路温升不影响传感器检测性能;(7)外接端口具有抗电磁干扰设计,可靠性高;(8)电源输入具有防反功能,电源输入正负反接不损坏设备。

(9)模块化结构,安装、维护方便。

四、安装连接图本传感器安装时需检查接线正确后,才能上电工作并测试相应功能。

五、基本功能描述5.1实时温、湿度显示本温湿度传感器需检查接线正确后,才能上电工作。

上电后若传感器工作正常,LCD将显示采集的温湿度值。

当室内温度无告警时,接线端子的3-4脚是常开状态;当室内湿度无告警时接线端子的5-6脚也是常开状态。

5.2按键功能说明本温湿度传感器设计有四个按键:菜单键、增加键、减少键、确认键,使用按键可设置相应的各种参数。

① MENU:在测量状态下按该键激活功能菜单。

②▲:增加键,在功能菜单激活状态下,按此键进行数字增加。

③▼:减少键,在功能菜单激活状态下,按此键进行数字减少。

④ ENTER:当菜单处于激活状态,按该键表示确认选择。

温湿度传感器产品说明书 ZZ-THS-ST

温湿度传感器产品说明书 ZZ-THS-ST

温湿度传感器产品说明书ZZ-THS-ST目录温湿度传感器产品说明书 (1)ZZ-THS-ST (1)1.产品简介 (3)1.1产品概述 (3)1.2功能特点 (3)2.参数详情 (4)2.1外形尺寸图 (4)2.2基本参数 (4)2.3模拟量参数含义 (5)2.3.1模拟量4-20mA电流输出 (5)2.3.2模拟量0-10V电压输出 (5)2.3.3模拟量0-5V电压输出 (6)2.4通讯协议 (6)2.4.1通讯基本参数 (6)2.4.2数据帧格式定义 (7)2.4.3寄存器地址 (9)2.4.4通讯协议示例以及解释 (9)3.安装使用 (11)3.1系统架构图 (12)3.1.1直接接电脑或者PLC (12)3.1.2网络传输使用 (13)3.2接口说明 (13)3.3接线说明 (14)3.3.1典型四线制接线方式 (14)3.3.2典型三线制接线方式 (16)3.4协议调试(只适用于485输出型) (17)4.包装售后 (21)4.1产品包装清单 (21)4.2联系方式 (21)4.3质保与售后 (21)4.4免责声明 (22)1.产品简介1.1产品概述该变送器广泛适用于农业大棚/花卉培养等需要温湿度监测的场合。

传感器内输入电源,感应探头,信号输出三部分完全隔离。

安全可靠,外观美观,安装方便。

1.2功能特点●探头灵敏度高●信号稳定,精度高●测量范围宽、线形度好●防水性能好、使用方便●便于安装、传输距离远等2.参数详情2.1外形尺寸图2.2基本参数参数技术指标温度测量范围-40℃-80℃(可定制)湿度测量范围0-100%RH温度测量精度±0.5℃(25℃典型值)湿度测量精度±3%RH(5%RH-95%RH,25℃典型值)(1)温度长期稳定性≤0.1℃/y温度长期稳定性≤1%/y通讯端口RS485Modbus协议/模拟量接口(电压型或者电流型)供电电源12V-24V DC最大功耗≤0.3W(@12V DC,25℃)外形尺寸110×85×44mm3电流输出类型4-20mA电流输出负载≤600欧姆电压输出类型0-5V/0-10V电压输出负载≤250欧姆工作压力范围0.9-1.1atm2.3模拟量参数含义2.3.1模拟量4-20mA电流输出电流值温度湿度4mA-45℃0%20mA115℃100%计算公式为P=(I-4mA)*6.25%其中I的单位为mA。

KC09131316-o09-常用温湿度传感器型号及参数-器.

KC09131316-o09-常用温湿度传感器型号及参数-器.

4
TSYS01数字温度传感器
TSYS01数字 温度传感器
简介: 小尺寸,低功耗,高精度,16/24位分辨率, 内置校正。可用于工业控制,替代热敏电阻 和NTC,供热/制冷系统,HVAC
5
TSYS01数字温度传感器 具体技术参数标准:
所属品牌: MEAS 输出: 24位数字输出 量程: -40℃~125℃ 封装:QFN16 工作温度范围:-40℃~125℃ 精确度:±0.1℃@-5℃~50℃ 供电电源:0.3~3.6V 特点:小尺寸,低功耗,高精度,16/24位 分辨率,内置校正 类型:数字温度传感器 电气连接:表面贴装 典型应用: 工业控制,替代热敏电阻和NTC, 供热/制冷系统,HVAC
6
TSYS01数字 温度传感器
SHT1x——数字式温湿度传感器(RH/T)
SHT1x数字式 温湿度传感器
简介: 数字式温湿度传感器SHT1x是一款可回流焊 传感器。SHT1x系列包含低成本版本SHT10、 标准版本SHT11和高端版本SHT15。所有 SHTxx系列的Sensirion传感器型号均经过 完全校准,并提供数字输出。 7
常用温湿度传感器 型号及参数
1
常用温湿度传感器类型及参数
• • • • • SHTC1 Sensirion数字温湿度传感器 TSYS01数字温度传感器 SHT1x数字式温湿度传感器 STS21数字温度传感器 STS21数字温度传字温湿度传感器
• SHTC1 Sensirion数字 温湿度传感器
8
STS21 - 数字温度传感器
STS21数字温 度传感器
简介: 3x3mm的微小体积,完全标定,高性能数 字温度传感器。 TS21温度传感器与SHT2x 温湿度传感器基于相同的芯片设计,具有优 越的性能,尺寸同样仅为3x3mm。温度传 感器与SHT2x具有不同的I2C地址,可pinpin兼容。因此STS21适用于温度为必测参 数,湿度为可选参数的场合,二者硬件相同, 用户无需更改硬件设计

TES-1360A 湿度温度仪说明书

TES-1360A 湿度温度仪说明书

TES-1360A Humidity/Temperature Meterz Laboratoryz Quality Controlz Air-Conditioningz Process EngineeringRange: Humidity 10% to 95% R.H.Temperature -20 ℃ to +60 ℃ ; -4 o F to +140 ℉Resolution 0.1% R.H. 0.1 ℃ , 0.1 ℉Accuracy (after calibration)Humidity +/ - 3% R.H. (at 25 ℃ , 30...95% R.H.)Temperature +/ - 0.8 ℃ , +/ - 1.5 ℉Response timeHumidity 45% R.H. --> 95% R.H. < = 3min 95% R.H. --> 45% R.H. < =5minTemperature 1 ℃ /2 secAccessories Carrying case, Instruction manual, Battery.Auxiliary outputsHumidity 10mV DC/1% R.H.Temperature 10mV DC/1 o C, 10mV DC/1 o FOperating / Storage Condition 0 ℃ to 50 ℃< 80% R.H. -10 ℃ to 60 ℃< 70% R.H.Power Source 10mV DC/1 ℃ , 10mV DC/1 ℉Size 270mm(L)x68mm(W)x25mm(H)Weight 200gAccessories Instruction Manual, Battery and Carrying CaseTES-1361C Datalogging Humidity/Temperature MeterInstant preformance of Humidity measurement by precision thin-film capacity sensorDual display LCD / ClockCompact, light weight & Simple operation7000 Record Data logging Capacity (Dual Reading)RS-232 interface (software included)TES Electrical Electronic Corp.TES-1362 Printing Humidity Temperature MeterTriple LCD Display for RH% Humidity, T1 for Air Temperature and T2 Type K Thermometer (-200 ℃ ~ 1333 ℃ ).Dew Point Reading.Max / Min / Data Hold.Real Time Stamp. Periodically Print out from Pre-Set time Interval.TES Electrical Electronic Corp.TES-1364/1365Datalogging Humidity Temperature MeterDetachable sensing probe.Data Hold & Relative function.Dual LCD display with Bargraph indication.Datalogging capacity 10,100 dual reading. (%RH &Temp). (TES-1365)Dew Point Reading.RS-232 interface & windows software. (TES-1365)Wet bulb Reading.Automatic Timer Recording for Datalogger. (TES-1365)MAX/MIN with Time Stamp.Measuring Range Temperature :-20℃~ 60℃(-4℉~ 140℉)Humidity : 1%RH ~ 99%RHResolution0.1℃/ 0.1℉/ 0.1%RHAccuracy Temperature : ±0.8℃, ±1.5℉Humidity : ±3%RHDatalogging (TES-1365)Manual recording : 99 data sets. (Direct reading from LCD display.) Continue recorder : 9999 data sets. (Automatic timer recording, RS-232 interface/software.)Input Protection60V DC or 24 Vrms AC maximum input voltage on any Combination of input Connector.Sampling Rate 1 times/secOperatingConditions0℃~ 60℃(32℉~ 140℉) & 10 ~ 80% R.H.Power Source 6 pcs size "AAA" BatteriesBattery Life Approx. 500 hoursSize &Weight152(L) ×72(W) ×35(H)mm & Approx. 235gAccessories 1. Carrying case, Instruction manual, Battery.2. RS-232 Interface & Windows Software. (TES-1365)3. H-1311 Rubber Holster (Optional)。

各类传感器分类与详情

各类传感器分类与详情

71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93
94 95 96 9பைடு நூலகம் 98 99 100 101 102 103 104 105 106 107 108
109 110 111 112 113 114 115 116
117 118 119 120 121
122
123
124 125 126 127 128 129 130 131
132 133 134
135 136 137 138 139 140 141
142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181
序号
1 2 3 4 5 6 7 8 9 10 11 12 13
14 15 16 17 18 19 20 21 22 23 24 25 26
27 28 29 30 31 32
33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51
52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70
(SKU:SEN0005)SRF02超声波测距传感器 (SKU:SEN0006)SRF05超声波测距传感器 (SKU:SEN0007)SRF08超声波测距传感器 (SKU:SEN0008)SRF10超声波测距传感器 (SKU:SEN0149)URM06-RS485 大功率超声波测距模块 (SKU:SEN0150)URM06-UART 大功率超声波测距模块 (SKU:SEN0151)URM06-PULSE 大功率超声波测距模块 (SKU:SEN0152)URM06-ANALOG 大功率超声波测距模块 (SKU:SEN0153)URM07-UART单探头超低功耗超声波测距传感器 (SKU:SEN0246)URM08-RS485 Waterproof Sonar Range Finder (SKU:SEN0243)URM08-UART Waterproof Sonar Range Finder (SKU:SEN0304)URM09 Ultrasonic Sensor(Gravity I²C)(V1.0)超声波传感器 (SKU:SEN0300)Water-proof Ultrasonic Sensor (ULS) (SKU:SEN0301)Water-proof Ultrasonic Sensor (ULA) (SKU:SEN0307)URM09 Ultrasonic Sensor(Gravity Analog)(V1.0)超声波传感器 (SKU:SEN0311)A02YYUW 防水超声波传感器 (SKU:SEN0312)ME007YS 防水超声波传感器 (SKU:SEN0313)A01NYUB 防水超声波传感器 (SKU:SEN0310)URM12 ultrasonic sensor(1500cm&RS485)

温湿度传感器使用说明书

温湿度传感器使用说明书

NO:S1*******使用说明书温湿度传感器目录1、产品介绍 (1)1.1概述 (1)1.2功能特点 (1)1.3外观尺寸 (1)2、性能参数 (2)3、使用方法 (4)3.1系统框架图 (4)3.2安装说明 (6)4、通信协议 (9)4.1通讯基本参数 (9)4.2数据帧格式定义 (9)4.3通讯基本参数 (11)4.4通讯协议示例以及解释 (12)5、常见问题及解决方法 (14)6、保养维护 (15)7、运输存储 (16)7.1运输要求 (16)7.2存储要求 (16)8、订货服务 (17)8.1订货方法 (17)8.2客户服务 (17)1产品介绍1.1概述本(系列)产品可在线监测环境温度和湿度信息,广泛用于开关柜仪表室、断路器室、电缆室等处的环境温湿度在线监测。

采用进口工业级微处理器芯片、进口高精度温度传感器,确保产品高精度和可靠性。

1.2功能特点◆进口的测量单元,测量精准。

◆专用的485电路,通信稳定。

◆宽电压范围供电,安装方便。

1.3外观尺寸(单位:mm公差:±0.5)2性能参数3使用方法3.1系统框架图本产品也可以多个传感器组合在一条485总线使用,理论上一条总线可以接254个485传感器,另一端接入带有485接口的PLC 、通过485接口芯片连接单片机,或者使用USB转485即可与电脑连接,使用我公司提供的传感器配置工具进行配置和测试(在使用该配置软件时只能接一台设备)。

3.2安装说明3.2.1注意事项1、传感器应尽量垂直放置,保证安装墙面时,温湿度探头在传感器本体的下方(传感器本体上的字体为正方向)。

2、安装高度为人体坐高或主要测量的环境区域。

3、避免在易于传热且会直接造成与待测区域产生温差的地带安装,否则会造成温湿度测量不准确。

4、安装在环境稳定的区域,避免直接光照,远离窗口及空调、暖气等设备,避免直对窗口、房门。

5、尽量远离大功率干扰设备,以免造成测量不准确,如变频器/电机等。

温湿度传感器型号大全

温湿度传感器型号大全

温湿度传感器型号大全1. DHT11温湿度传感器•型号:DHT11•工作电压:3.3V-5V•测量范围:温度0-50°C,湿度20-90%RH•精度:温度±2°C,湿度±5%RH•特点:低成本,数字输出,单线串行通信2. DHT22温湿度传感器•型号:DHT22•工作电压:3.3V-5V•测量范围:温度-40-80°C,湿度0-100%RH•精度:温度±0.5°C,湿度±2%RH•特点:数字输出,较高精度,需要外部电阻3. AM2302温湿度传感器•型号:AM2302•工作电压:3.3V-5V•测量范围:温度-40-80°C,湿度0-100%RH•精度:温度±0.5°C,湿度±2%RH•特点:数字输出,与DHT22相同4. SHT11温湿度传感器•型号:SHT11•工作电压:2.4V-5.5V•测量范围:温度-40-123.8°C,湿度0-100%RH•精度:温度±0.5°C,湿度±3%RH•特点:数字输出,较低功耗5. SHT15温湿度传感器•型号:SHT15•工作电压:2.4V-5.5V•测量范围:温度-40-123.8°C,湿度0-100%RH•精度:温度±0.3°C,湿度±2%RH•特点:数字输出,较高精度,带有可选的I2C接口6. HTU21D温湿度传感器•型号:HTU21D•工作电压:3.3V-5V•测量范围:温度-40-125°C,湿度0-100%RH•精度:温度±0.3°C,湿度±2%RH•特点:数字输出,高精度,可通过I2C接口进行通信7. BME280温湿度传感器•型号:BME280•工作电压:1.71V-3.6V•测量范围:温度-40-85°C,湿度0-100%RH•精度:温度±0.5°C,湿度±3%RH•特点:数字输出,温湿度压力三合一传感器,可通过I2C或SPI接口进行通信8. BME680温湿度传感器•型号:BME680•工作电压:1.71V-3.6V•测量范围:温度-40-85°C,湿度0-100%RH•精度:温度±0.5°C,湿度±3%RH•特点:数字输出,温湿度压力气体四合一传感器,可通过I2C或SPI 接口进行通信9. HDC2080温湿度传感器•型号:HDC2080•工作电压:1.62V-3.6V•测量范围:温度-40-125°C,湿度0-100%RH•精度:温度±0.2°C,湿度±2%RH•特点:数字输出,高精度,可通过I2C接口进行通信以上是一些常见的温湿度传感器型号及其主要参数介绍。

国际品牌温度传感器介绍一

国际品牌温度传感器介绍一

一、霍尼韦尔公司简介:霍尼韦尔是《财富》百强公司,总部位于美国。

致力于发明制造先进技术以应对全球宏观趋势下的严苛挑战,例如生命安全、安防和能源。

公司在全球范围内拥有大约130,000 名员工,其中包括19,000 多名工程师和科学家。

霍尼韦尔在华的历史可以追溯到1935年。

当时,霍尼韦尔在上海开设了第一个经销机构。

1973年美国总统尼克松访华时,应中国政府之邀从十大领域推荐精英企业来华推动两国双向交流,并促进中国的现代化建设。

其中炼油石化领域唯一被选中推荐给中国政府的美国环球油品公司,正是霍尼韦尔旗下的子公司。

80年代的改革开放成为了霍尼韦尔融入中国经济发展的又一个新起点,作为首批在北京设立代表处的跨国企业,霍尼韦尔在彼时开始了一系列的高品质投资。

目前,霍尼韦尔四大业务集团均已落户中国,旗下所辖的所有业务部门的亚太总部也都已迁至中国,并在中国的20多个城市设有多家分公司和合资企业。

目前,霍尼韦尔在中国的投资总额超10亿美金,员工人数超过12,000名。

主要产品及服务:家具与消费品——环境自控解决方案及产品航空与航天——航空航天UOP中国传感与控制生命安全与安防——霍尼韦尔安全产品安防气体探测技术建筑、施工与维护——环境自控解决方案及产品安防英诺威发泡剂极冷致制冷剂传感与控制——扫描与移动生产力扫描与移动技术工业过程控制——无线自动化解决方案环境自控解决方案及产品传感与控制气体探测技术能效与公共事业——环境自控解决方案及产品无线自动化解决方案传感与控制汽车与运输——极冷致制冷剂传感与控制石油、天然气、炼油、石油化工与生物燃料——环境自控解决方案及产品UOP中国无线自动化解决方案传感与控制气体探测技术安防医疗保健——扫描与移动技术阿克拉薄膜传感与控制Burdick & Jackson 溶剂和试剂化学品、特殊材料与化肥——Burdick & Jackson 溶剂和试剂阿克拉薄膜尼龙6树脂UOP中国极冷致制冷剂OS有机硅密封胶添加剂制造——环境自控解决方案及产品尼龙6树脂A-C高性能添加剂传感与控制无线自动化解决方案温度传感器:1、Megopak热电偶霍尼韦尔Megopak热电偶将多年研究和现场试验的成果相结合,其简单坚固的设计非常适合恶劣工业环境下的大范围温度测量。

温湿度传感器使用说明书

温湿度传感器使用说明书

温湿度传感器使用说明书●产品概述该温湿度大气压传感器可广泛适用于环境检测,集温湿度、大气压力于一体,安装在百叶盒内,设备采用标准MODBUS-RTU通信协议,RS485信号输出。

该变送器广泛适用于需要测量环境温湿度等场合。

●产品特点●10-30V宽直流电压供电●标准MODBUS-RTU通信协议●宽范围气压量程,可应用于各种海拔高度●技术指标供电电压10~30VDC温度±0.5℃(25℃)精度相对湿度±3%RH(5%RH~95%RH,25℃)温度-40℃~80℃测量范围相对湿度0%RH~100%RH温度0.1℃显示分辨率相对湿度0.1%RH温度0.1℃/y长期稳定性相对湿度0.1%RH/y输出信号(0-5)V、(0-10)V、(4-20)mA、RS485(Modbus RTU通讯协议)工作温度-20~60℃储存温度-40~100℃●产品电气接口及连线方法数字RS485输出接线方式线色引线定义电源红色电源正(10~30V DC)黑色电源负通信绿色RS485-A 白色RS485-B模拟输出接线方式线色引线定义电源红色电源正(10~30V DC)黑色电源负通信绿色温度信号输出正白色温度信号输出负蓝色湿度信号输出正黄色湿度信号输出负注:接线方式以产品引线上说明为准●注意事项1打开产品包装后,请检查产品外观是否完好,核定产品使用说明书相关内容与产品是否一致,并妥善保管产品使用说明书一年以上;2严格按产品接线示意图接线,并在产品允许激励电压下工作,切勿过电压使用;3产品切莫敲打,以免损环外观和内部结构;4产品无客户自行维修部件,出现故障时请与我公司联系;5本公司产品正常情况下使用出现故障,保修期为一年(自我公司发货之日起至返回之日止13个月),是否属于正常情况下出现故障,以我公司质检员检测为依据。

超过期限维修,本公司收取成本费,本公司所有产品终身维修;6未尽之处,请查阅我公司网站或来电查询。

CAREL 温度和湿度传感器 说明书

CAREL 温度和湿度传感器 说明书
可以用于风道型的加热器和空调系统中。它们配备有温度传感器(NTC或PT1000)和/或湿度传感器。 壁挂式探头(ASW*)
它们应用于加热器和空调系统。它们的外形美观适合室内安装。这些型号提供墙上安装。 温度探头:户外型(ASE*),浸入式(ASI*)
一般情况下,为了普通应用而设计的外部探头的电缆长度从2m到4m。若选择电流输出,探头可以被远程安 装在200m远的地方。
代码 1413306AXX 1413309AXX
1.3安装
连接 以下是与终端连接的电路接线图和把电压输出变成电流输出的跳线的配置电路图。
端子: outT=温度输出(0~20mA或-0.5V~1Vdc) outH=湿度输出(0~1Vdc或4~20mA) M =电源和输出的地线 +(G)=电源(12~24Vac或9~30Vdc) ntc =NTC阻性输出 注意:输出为0-1Vdc,负载必须>1kΩ;输出为4-20mA,负载必须≤100Ω。 警告:
范围 -10~70℃
-10~70℃
10~90%rH
0~50℃ 10~90%rH;
0~50℃ 10~90%rH
代替 SSTOOA00/1,SSTOOA0420,SSTOOA0000 SSWNTC0000 SHWOOP00/1,SHWOOP0420,SHWOOP0000 STHOAP00/1,STHOAP0000
需要感应元件直接和被控的液体接触时,浸入式探头安装在冷冻或者加热回路中。这种情况下,传感器可 以是PT1000,B级。 通用型探头(ASP*)
可以用于特殊的环境中(冷冻室,游泳池等等),在这种环境中箱体(IP55)和传感器(IP54)需要高的 防护等级。它与温度传感器(PT1000或NTC)和湿度传感器配合使用。墙上安装。

温度与湿度传感器技术指南说明书

温度与湿度传感器技术指南说明书

定义响应时间通常使用两个不同指标来定义响应时间:T 63 和 T 90。

当被测参数量值有瞬时变化时,测量值需要多长时间达到最终值的 63% 或 90%。

以下是为什么选择 63% 来定义响应时间的原因:T 63 在一阶线性时域不变系统中等于时间常数,该常数通常用希腊字母 τ (tau) 来表示。

这个一阶线性时域不变系统的数学模型描述了某一物理系统对阶跃变化呈指数曲线的反应(图 1)。

这意味着系统将在一个时间常数内达到最终值的63%,在三个时间常数内达到最终值的95%,在四个时间常数内达到最终值的98%。

湿度传感器将根据相对湿度(从定义上看与温度有关)寻求与周围环境达到平衡。

因此,在温度保持不变的环境下,相对湿度传感器的响应时间只跟周围环境湿度相关。

温度变化时,除非探头的温度已稳定,否则传感器的相对湿度测量将是不正确的。

因此,仪表的总响应时间由湿度传感器的响应时间和温度变化的响应时间来定义。

变化的环境中的准确控制在需要准确控制时,响应时间变得至关重要。

当系统由某个仪表提供的反馈信号控制时,对于相较此仪表的响应时间更快的变化,控制器将无法做出反应。

换句话说,测量仪表还未对快速且短暂的变化做出反应,也将无法准确地控制系统以响应这些变化。

在最糟的情况下,因为频繁地调整控制器,测量仪表导致的迟滞可能引起不必要的波动或延长达到稳定的时间。

一般来说,当大约是受控系统中最短时间常数的一半时,仪表的响应时间应是足够的。

图 2 说明在温度波动范围为 ±1 °C 的环境下,温度响应时间对相对湿度测量准确度的影响。

技术指南在理想条件下,所有测量仪表都应是 100% 准确的。

但在现实环境中,有很多因素都可能会影响测量准确度。

其中一个因素是仪表的响应时间。

响应时间可以定义为传感器能以多快速度响应测量参数的变化,并且会对测量性能产生重大影响。

输入输出传感器请联系我们,网址为:/contactus扫描代码获取更多信息Ref. B211803ZH-B ©Vaisala 2021本资料受版权保护,维萨拉及其合作伙伴保留所有版权。

智慧家居温湿度传感器说明书

智慧家居温湿度传感器说明书

温湿度传感器Wis-16TH使用说明感谢您购买iWiscloud系列传感器,为了使您能够安全、正确地使用本产品,使用前请务必阅读本说明书,阅读后请妥善保管,以便随时查阅参考。

一、传感器的功能与应用场合作用与用途:本传感器可对周围空气进行温度、湿度检测,用户可以参考本传感器进行适当的调节环境温湿度。

应用场合:医药存储、运输、食品存储、运输、档案室、家庭、生产车间、仓库、机房、工地及其他相关湿度测控的场合等。

二、传感器产品特性1.工作电源:12VDC2.测温范围:0-50℃3.测温精度:±2℃4.测湿范围:20-90%RH5.测湿精度:±5%RH6.工作环境:-20~75℃,5~95%RH三、产品外形结构及操作说明四、应用信息1、工作与贮存条件超出传感器建议的工作范围可能导致高达3%的临时性漂移信号。

返回正常工作条件后,传感器会缓慢地向校准状态恢复。

在非正常工作条件下长时间使用,会加速产品的老化。

避免将元件长期放在结露和干燥的环境中以及以下环境。

A、盐雾B、酸性或氧化气体,例如二氧化硫,盐酸推荐的存储环境温度:10~40℃湿度:60%RH 以下2、暴露在化学物质中的影响传感器的感应层会受到化学蒸汽的干扰,化学物质在感应层中的扩散可能导致测量值漂移和灵敏度下降。

在一个纯净的环境中,污染物质会缓慢地释放出去。

下文所述的恢复处理将加速实现这一过程。

高浓度的化学污染(如乙醇)会导致传感器感应层的彻底损坏。

3、温度影响气体的相对湿度,在很大程度上依赖于温度。

因此在测量湿度时,应尽可能保证湿度传感器在同一温度下工作。

如果与释放热量的电子元件共用一个印刷线路板,在安装时应尽可能将传感器远离电子元件,并安装在热源下方,同时保持外壳的良好通风。

为降低热传导,传感器与印刷电路板的其它部分铜镀层应尽可能最小,并在两者之间留出一道缝隙。

4、光线影响长时间暴露在太阳光下或强烈的紫外线辐射中,会使性能降低。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

ATC60A0温湿度传感器在智能家居中的应用
随着科技水平的日益进步,人类的生活水平也在逐步的提高,对家居智能化也有了渴求,智能家居在今后的市场将越来越大。

下面介绍一种温湿度采集系统在智能家居的应用方案。

该方案采用ATC60A0系列温湿度传感器,C8051F985低功耗MCU,CP2403LCD驱动和显示器构建一个家庭温湿度采集系统,用来检测室内外温湿度数据。

温湿度采集系统的工作原理
分别在室内外安装两个2个ATC60A0系列温湿度传感器,定时唤醒采集温湿度的原始数据,在ATC60A0系列内部进行AD转换,经过IC总线送往C8051F985处理。

C8051F985可以根据需要启用哪个采集节点的数据来降低能耗,并控制CP2403LCD驱动,最终的数据在LCD显示屏上显示,方便用户读取。

温湿度采集系统的性能参数
一、各主要节点的功耗
1、ATC60A0系列
ATC60A0系列温度测量周期内电流大小为320微安,湿度测量周期内电流大小为240微安,睡眠电流为0.2微安,如果每分钟进行一次温湿度采集,则温湿度传感器平均功耗大约在1微安。

2、C8051F985
睡眠电流10nA,工作电流150uA/MHz
3、CP2403
睡眠电流0.02微安,工作电流小于3微安。

假如按每分钟进行一次测量,工作频率在4MHz,那么平均功耗将小于15微安,所以可以采用电池进行供电,用起来也方便。

二、数据采集范围
ATC60A0系列的温度量程为-40到85℃,在25℃时的精度为±0.5℃。

湿度量程为5到90%RH,在20%到80%RH条件下精度为2到3%RH。

家庭使用的话完全能满足要求。

具体实施的时候建议在室外布置一个采集点,室内客厅、卧室布置两个采集点,
采集到的数据交给控制系统,用来调节室内温湿度。

三、可扩展性
家庭数据采集系统除了利用温湿度传感器以外,还可以加上烟雾传感器,火情报警器,热释电红外传感器等等,然后通过I?C总线技术,送给功能更强大的处理器进行数据处理,即可实现功能的扩展。

节电布置的时候要综合考虑,以便节约成本。