LDD-F5406RI, 规格书,Datasheet 资料

合集下载

维vider NoFrost 7085 511-01 CNP 4056 无冻成分电子冰箱用户手册说明

维vider NoFrost 7085 511-01 CNP 4056 无冻成分电子冰箱用户手册说明

Installation instructions.............................................................................................................................................. Page 20Operating instructions................................................................................................................................................... Page 14NoFrost combined refrigerator-freezerRead the operating instructions before switching on for the first timeInstallation instructions ................................................................................................................................................. Seite 8Adjustable storage shelvesAdjustable door racksType plate Disposal notesThe appliance contains reusable materials and shouldbe disposed of properly - not simply with unsortedhousehold refuse. Appliances which are no longerneeded must be disposed of in a professional andappropriate way, in accordance with the current localregulations and laws.When disposing of the appliance, ensure that the refrigerant circuitis not damaged to prevent uncontrolled escape of the refrigerantit contains (data on type plate) and oil.• Disable the appliance.• Pull out the mains plug.WARNINGplastic film!Do not allow children to play with packaging ma-terial. Take the packaging material to an officialcollection point.Range of appliance useThe appliance is suitable solely for cooling food ina domestic environment or similar. This includes,for example, use- in staff kitchenettes, bed and breakfast establish-ments,- by guests in cottages, hotels, motels and otherforms of accommodation,- in catering and similar services in the wholesaletrade.Use the appliance solely as is customary within a domestic envi-ronment. All other types of use are inadmissible. The applianceis not suitable for storing and cooling medicines, blood plasma,laboratory preparations or similar substances and products cov-ered by the 2007/47/EC Medical Devices Directive. Any misuseof the appliance may result in damage to or spoilage of storedgoods. Furthermore, the appliance is not suitable for operationin potentially explosive atmospheres.Bottle racktipping. This can lead to injury or property damage.Unscrew the additional adjustable foot on thesupport until it reaches the floor.Then turn it another 90°.ecodesign requirements will be available in the European productdatabase (EPREL). You can access the product database usingthe following link: https://eprel.ec.europa.eu/. You will be askedto enter the model identifier. You will find the model identifier onthe type plate.14ENSafety instructions and warnings• T o prevent injury or damage to the unit, the ap-pliance should be unpacked and set up by two people.• In the event that the appliance is damaged on delivery, contact the supplier immediately before connecting to the mains.• T o guarantee safe operation, ensure that the ap-pliance is set up and connected as described in these operating instructions.• Disconnect the appliance from the mains if any fault occurs. Pull out the plug, switch off or remove the fuse.• When disconnecting the appliance, pull on the plug, not on the cable.• Any repairs and work on the appliance should only be carried out by the customer service department, as unauthor i sed work could prove highly dangerous for the user. The same applies to changing the mains power cable.• Do not allow naked flames or ignition sources to enter the appliance. When transporting and cleaning the appliance ensure that the refrigerant circuit is not damaged. In the event of damage, make sure that there are no ignition sources nearby and keep the room well ventilated.• Do not stand on the plinth, drawers or doors or use them to support anything else.• This appliance can be used by children of 8 years old and over, and also by persons with restricted physical, sensory or mental capacity or lack of experience and knowledge, if they are supervised or have been instructed on safe use of the appli-ance and understand the resulting risks. Children must not be allowed to play with the appliance. Cleaning and user maintenance must not be carried out by children without supervision.• Avoid prolonged skin contact with cold surfaces or chilled/frozen food. T his could cause pain, numb-ness and frostbite. In the case of prolonged skin contact, protective measures should be taken, e.g. gloves should be worn.• Do not eat ice cream, particularly ice lollies or ice cubes, immediately after taking them from the freezer compartment as there is a risk of "burn-ing" because of the very cold temperatures.• Do not consume food which has been stored for too long, as it could cause food poisoning.• Do not store explosives or sprays using com-bustible propellants such as butane, propane, pentane, etc. in the appliance. Electrical com-ponents might cause leaking gas to ignite. Y ou may identify such sprays by the printed contents or a flame symbol.• Do not use electrical appliances inside the ap-pliance.• The appliance is designed for use in enclosed areas. Do not operate the appliance outdoors or in areas where it is exposed to splash water or damp conditions.• The LED light strips illuminate the interior of the appliance. They are not suitable for lighting a room.Climate ratingeration performance.type plate.The position of the type plate is shown inthe section entitled Description of the appliance. Climate rating Room temperatureSN +10°C to +32°CN +16°C to +32°CST +16°C to +38°CT +16°C to +43°CSN-ST +10°C to +38°CSN-T +10°C to +43°CDo not operate the appliance outside thespecified room temperature range.Setting up• Avoid positioning the appliance in direct sunlight or near cookers, radiators and similar sources of heat.• The floor on which the appliance stands should be horizontal and level. T o compensate for any unevenness, adjust the height••of 1 mused in your appliance is indicated on the type plate on the inside of the appliance.1516Switching the appliance on and offClean the interior of the appliance before switching it on for the first time (see "Cleaning ").To switch onPress the On/Off button (1) or (6) so that the temperature displays light up.To switch the refrigerator com-partment offPress the On/Off button (1) for ap -prox. two seconds.Note: If the freezer compartment (On/Off button (6)) is switched off, the entire appliance will beswitched off.Operating and control elements(1) On/Off button, refrigerator compartment (2) Alarm symbol (3) SuperCool button (4) SuperFrost button (5) SuperFrost symbol(6) On/Off button, freezer compartment (7) Ventilation button (8) Alarm button(9) Down setting button, freezer compartment (10) Freezer compartment temperature display (11) Up setting button, freezer compartment(12) Refrigerator compartment temperature display (13) Down setting button, refrigerator compartment (15) Up setting button, refrigerator compartment (16) Child-proofing symbol (17) Power failure symbol(18) Menu symbol > Setup mode is activated (activating thechild lock and adjusting the display brightness)(19) SuperCool symbolElectrical connectionOnly operate the appliance with alternating current (AC).The permissible voltage and frequency are indicated on the type plate. The position of the type plate is shown in the section entitled Description of the appliance .The socket must be properly earthed and protected by a fuse.The tripping current of the fuse must be between 10 A and 16 A.sion cable or extension socket.Setting the temperatureSetting the refrigerator temperatureWarmer temperature setting > press button (15)Colder temperature setting > press button (13)Setting the freezer temperatureWarmer temperature setting > press button (11)Colder temperature setting > press button (9)- While you are setting the tempera-ture, the temperature display will flash.buttons for the first time, the set temperature will be displayed.pressing the buttons again.- About 5 seconds after the button was last pressed the average inte-rior temperature will be displayed.Adjustable temperature ranges to 2°C.Temperature displayFactory setting = degrees FahrenheitChanging the temperature display to Celsius• Press the SuperFrost button (4) for about 5 seconds. Display =• Using the Up button (11) or Down button (9) select .• Press the SuperFrost button (4). Display =.• Press the SuperFrost button (4). Display =• Press the On/Off button (6).degrees Celsius.17ENBrightness of the temperature displayThe brightness is adjustable between 0 (no illumination) and5 (maximum brightness).• Press the SuperFrost button (4) for about 5 seconds. Display =• Using the Up button (11) or Down button (9) select .• Press the SuperFrost button (4).•press Up button (11).• T o make the display darker: press Down button (9).• Press the SuperFrost button (4).• The brightness is adjusted to the new value.• Press the On/Off button (6).Audible warning signalAudible door alarmIf an appliance door is left open for more than 180 seconds, the audible warning signal will sound. Press the audible warning on/off button back to standby when the door is shut.Audible/visual temperature alarmIf the temperature in the freezer compartment will sound and the alarm symbol (2) and the temperature display will flash.Press the audible warning on/off button (8) to cancel the alarm. The symbol (2) will stop flashing. The symbol (2) will disappear as soon as the temperature in the freezer compartment is low enough.This can be caused by:time, allowing warm ambient air to enter;• a long power failure;• a fault in the appliance.In each case, make sure food has not thawed or perished. If the alarm symbol does not go out, contact the customer service department (see section on Malfunctions).Child lockThe child lock is designed to protect the appliance from being switched off accidentally.Display =• Using the Up button (11) or Down button (9) select .• Press the SuperFrost button (4).When 1display:• T o activate the child lock, brieflypress the SuperFrost button (4).• The child lock symbol lightsup. flashes in the display.When0 is indicated in the display:• T o deactivate the child lock, briefly press the SuperFrost button (4).• The child lock symbol goes out.flashes in the display.• Press the On/Off button (6).Sabbath modeThis function complies with the religious requirements to be observed on the Sabbath or religious holidays.When Sabbath mode is activated, some of the functions of the control electronics are switched off.• The interior light remains switched off if one of the appliance doors is opened.• The interior fan remains in the status which is currently set (On or Off) if an appliance door is opened.• No door open alarm.• No temperature alarm.• Press the SuperFrost button (4) for about 5 seconds. Display = • Press the SuperFrost button (4).Display =• Press the SuperFrost button (4). Display =• Press the On/Off button (6).The sabbath mode is activated.Der Sabbat-Modus deaktiviert sich automatisch nach 120 Stun-den.Deactivating the sabbath mode• Press the SuperFrost button (4) for about 5 seconds. Display =• Press the SuperFrost button (4). Display = • Press the SuperFrost button (4). Display = • Press the On/Off button (6).The sabbath mode is deactivated.18large quantities of food are to be cooled rapidly.To switch on: Press the Super-Cool button (3) briefly > LED (19) lights up.Note:switches off automatically after about 6 hours.Cooling with fanWith the fan function switched on, a uniform temperature distribu-tion will be attained in the refrigerator compartment.This is recommended:- in high room temperatures (approx. 33°C or higher),- if the air humidity is high (e.g. during the summer).To switch onCooling(1) butter, cheese (2) eggs (3) bottles(4) baked goods, pre-cooked meals (5) (6) fruit, vegetables, salads (7) frozen food, ice cubesNotecontainers.Repositioning the door racks- Lift door rack vertically (1- By shifting the opening or closing the door.EquipmentYou can re-arrange the storage shelves as required.Lift the glass shelf, align the recess over the support and replace the shelf in a higheror lower position.Place the shelf rails provided, fig. 1, on the supports on the left and right at the desired height.Insert the glass shelves (1) and (2) as shown in fig. 2.If you need to make space for tall containers, simply slide the front half of the sectioned glass shelf carefully underneath the back half, fig. 2.If the cover is removed, do not look directly at the light through optical lenses from close distance. This can dam-age your eyes.Power failure display If appears in the display, the freezer temperature has risen too high due to a power failure.• Press the Alarm button (8).> The highest temperature during the power failure will be displayed.displayed.Do not eat perished food!Do not refreeze thawed food!Press the Alarm button (8) again to cancel the display.19ENMalfunctionsYou may be able to rectify the following faults by checking the possible causes yourself:• Appliance does not function:– Is the appliance switched on?– Is the plug correctly fitted in the mains socket?– Is the fuse intact?• Loud running noise:– Is the appliance set up firmly on the floor?– Does the appliance cause nearby items of furniture or objects to vibrate? Please note that noises caused by the refrigerant circuit cannot be avoided.• The temperature is not low enough:– Is the temperature setting correct (see "Setting the temperature")?– Have excessive amounts of fresh food been placed in the appli-ance? – D oes the separately installed thermometer show the correct reading?– I s the ventilation system working properly?– Iber ber type plate.Shutting your appliance downIf your appliance is to be shut down for any length of time, switch it off and disconnect the plug or switch off or unscrew the fuse. Clean the appliance and leave the door open in order to prevent unpleasant smells.The appliance complies with the relevant safety regulations and EU Directives 2014/30/EU and 2014/35/EU.CleaningBefore cleaning, always switch off the appliance. Disconnect from the mains or switch off or unscrew the fuse.• First clean the side panels with a conventional stainless steel cleaner. Subsequently, apply the enclosed stainless steel care product evenly onto the surfaces in the same direction in with they have been ground or polished.• Only clean the door surfaces with a clean and soft cloth. If nec-essary, moisten the cloth (water + detergent). Alternatively, use a micro-fibre cloth.- Do not use abrasive sponges or scourers, do not use concentrated cleaning agents and never use cleaning agents containing sand, chloride or acid or chemical solvents, as these would damage the surfaces and could cause corrosion.• Clean the inside and equipment parts with lukewarm water and a little detergent.Do not use steam cleaners because of the risk of injury and damage.• Ensure that no cleaning water penetrates into the electrical components or ventilation grille.• Dry all parts well with a cloth.• Do not damage or remove the type plate on the inside of the appliance. It is very important for servicing purposes.Freezingance .SuperFrostBy activating the SuperFrost function the temperature in the freezer compartment will drop to the lowest attainable value. Thus food up.• • hours.Y ou should not switch on the SuperFrost function:- when placing frozen food in the freezer,- when freezing up to approx. 2 kg fresh food daily.Notes on freezing and storage• Pack food which you are freezing yourself in quantities appropriate to your household. T o ensure that the food freezes right through, the following quantities should not be exceeded per package: fruit, vegetables: up to 1 kg, meat: up to 2.5 kg.• Pack frozen food in standard freezer bags or reuseable plastic, metal or aluminium containers.• Do not allow fresh food which is to be frozen to come into contact with food already frozen. Always keep packs dry in order to avoid them sticking together.• Always write the date and contents on the pack and do not exceed the stated storage time for the food.• Do not freeze bottles and cans which contain carbonated drinks as they might burst.• Only take out as much food as is immediately required for thawing. Use food which has been thawed in prepared meals as quickly as possible.Frozen food can be thawed in the following ways:- in a fan oven,- in a microwave oven,- at room temperature,- in the refrigerator.20Appliance dimensions The appliance can be used freestanding or semi built-in.If semi built-in, please consider the cabinet opening dimensions.Installation dimensionsIMPORTANTThe socket must not be situated behind the appli-ance and must be easily accessible.EN Unit ventingDo not restrict the air flow.installed in a soffit (3).IMPORTANTthe upper one.The section below the freezer door and the floormust not be covered.down until it has proper floor contact to support thehinge bracket.21Mounting the anti tipping deviceWARNING!Tip over hazard!The anti tipping brackets must be mounted to prevent the appliance from tipping when the fully stocked door is opened.IMPORTANTBe sure that there is no plumbing or electrical wiring located in this area which screws or drills could damage.1. Mark the center of the appliance on the back wall.2.Mount the anti tipping brackets within the given area.IMPORTANTThe screws for fastening the anti-tip device are not supplied with the appliance. Appropriate screws must be used for the material (wood, concrete, etc.) in which the safety device is mounted.Changing over door hingesDoor hinges should only be changed by a trained expert.1.the left.T op right2.3.the hinge.4.you.5.6.7.T op right8.9.door.22EN10.Tposite side.11.Topposite side.Bottom right12.13.Bottom right14.15.16.17.24Both doors32.the front and slide away.33. T plugs to the other side.Bottom of appliance 29. T ransfer cover plate to theopposite side.30. Screw hinge bracket intoplace.Bottom left31. using the adjustable foot.Centre left of appliance39. 34. T ransfer panels of bothdoor covers to the oppo-site side.Both doors 35.36.Bottom left40.50.least 90°.T op left51.52.Refrigerator door45.46.cable.Refrigerator door47.Refrigerator door48.sert hinge.49.Bottom left44.Click cover into place.insert pin.op leftdoor.op rightPlace the appliance in its finalat the place of installation.floor and then make a further25Liebherr Hausgeräte Lienz GmbHDr.-Hans-Liebherr-Strasse 1A-9900 LienzÖsterreich40。

IRGP4086PBF;中文规格书,Datasheet资料

IRGP4086PBF;中文规格书,Datasheet资料
TJ = 25°C
tf
Fall time
td(on)
Turn-On delay time
tr
Rise time
— 65 —
— 30 —
IC = 25A, VCC = 196V
— 33 — ns RG = 10Ω, L=200μH, LS= 200nH
td(off) tf tst
EPULSE
Turn-Off delay time Fall time Shoot Through Blocking Time
2
/

240
VGE = 18V
200
VGE = 15V
VGE = 12V
160
VGE = 10V VGE = 8.0V
120
VGE = 6.0V
ICE (A)
80
40
0
0
4
8
12
16
VCE (V)
Fig 1. Typical Output Characteristics @ 25°C
––– 29 ––– ––– 65 ––– ––– 22 ––– — 36 — — 31 — — 112 —
S VCE = 25V, ICE = 25A nC VCE = 200V, IC = 25A, VGE = 15Ve
IC = 25A, VCC = 196V ns RG = 10Ω, L=200μH, LS= 200nH
Parameter Thermal Resistance Junction-to-Case-(each IGBT) d Case-to-Sink (flat, greased surface) Junction-to-Ambient (typical socket mount) d Weight

ERDN40-SPEC 2019-08-19 产品说明书

ERDN40-SPEC 2019-08-19 产品说明书

OTHERS DIMENSION
97*99*36mm (W*D*H)
PACKING
0.276Kg;45psc/14Kg/0.98CUFT
NOTE
1. All parameters NOT specially mentioned are measured at normal input , rated load and 25℃ of ambient temperature. 2. Derating may be needed over high ambient temperature. Please check the derating curve for more details. 3. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude
9 19 36
12
14
24
29
48
60
INPUT VOLTAGE (V)
File Name:ERDN40-SPEC 2019-08-19
40A Enclosed Type Redundancy Module
Typical Application Notes
1. 1+1 Redundancy: Using 1 more PSU as the redundant unit
Note.3 5000 meters/OVC II
SAFETY STANDARDS WITHSTAND VOLTAGE
IEC62368-1, UL62368-1, EAC TP TC 004 approved IP/OP - Chassis : 0.5KVac ; IP/OP- Relay : 0.5KVac ; Relay - Chassis : 0.5KVac

英飞凌 ICE5QRxx80BG 第五代准谐振集成电源IC 数据表

英飞凌 ICE5QRxx80BG 第五代准谐振集成电源IC  数据表

采用 DSO-12 封装的准谐振 800 V CoolSET ™产品亮点• 集成 800 V CoolMOS ™,雪崩能力强 • 创新型准谐振操作,其专有设计可降低 EMI• 可选进入和退出待机功率电平的增强型主动突发模式 • 主动突发模式,最低待机功率可小于 100 mW • 借助共源共栅配置实现快速启动 • 数字降频模式,提高整体系统效率 • 支持输入过压和欠压保护的可靠线路保护 • 完善的保护机制•无铅电镀、无卤模塑化合物,符合 RoHS 标准特性• 集成 800 V CoolMOS ™,雪崩能力强• 显著缩小高低压线路间的开关频率差,实现高效率和良好的 EMI 性能• 可选进入和退出待机功率电平的增强型主动突发模式 • 主动突发模式,最低待机功率可小于 100 mW • 借助共源共栅配置实现快速启动 • 数字降频技术,过零点可达 10 个 • 内置数字软启动 • 逐周期峰值电流限制• 最大导通/关断时间限制,以避免在启动和断电时产生噪音 • 支持输入过压和欠压保护的可靠线路保护•针对 VCC 过压、VCC 欠压、过载/开路、输入/输出过压及过温状况的自动重启模式保护• 受限的 VCC 短接至地的充电电流• 无铅电镀、无卤模塑化合物,符合 RoHS 标准应用• 适用于家用电器/白色家电、电视、电脑及服务器的辅助电源• 蓝光播放器、机顶盒和 LCD/LED 显示器描述准谐振 CoolSET ™ - (ICE5QRxx80BG) 是第五代准谐振集成电源 IC ,支持共源共栅配置,并针对离线开关模式电源进行了优化。

产品在单一封装中搭载了两个独立芯片,分别为控制器芯片和高压 MOSFET 芯片。

借助经改善的数字降频技术和专有的创新型准谐振操作,IC 可在实现低 EMI 效果时兼顾更高效率。

而增强型主动突发模式更是为待机功率范围的选择提供了灵活性。

此外, ICE5QRxx80BG 有宽的供电电压工作范围 (10.0~25.5 V), 功耗较低。

DC DC模块电源IB05_S-W75R3系列商品说明书

DC DC模块电源IB05_S-W75R3系列商品说明书

选型表认证产品型号输入电压(VDC)输出满载效率(%)Min./Typ.最大容性负载(µF)标称值(范围值)电压(VDC)电流(mA)Max./Min.CEIB0503S-W75R35(4.75-5.25)3.3200/2064/682400IB0505S-W75R35150/1568/722400IB0509S-W75R3983/968/721000IB0512S-W75R31262/769/73560IB0515S-W75R31550/570/74560输入特性项目工作条件Min.Typ.Max.单位输入电流(满载/空载)3.3VDC/5VDC 输出--209/5221/10mA9VDC/12VDC 输出--208/12221/2015VDC 输出--202/18215/30反射纹波电流*--15--输入滤波器类型电容滤波热插拔不支持注:*反射纹波电流测试方法详见《DC-DC (定压)模块电源应用指南》。

输出特性项目工作条件Min.Typ.Max.单位输出电压精度----±3%线性调节率输入电压变化±1%----±0.25%负载调节率10%-100%负载 3.3VDC 输出----±3%其他输出----±2纹波&噪声*20MHz 带宽--3075mVp-p 温度漂移系数100%负载--±0.02--%/℃短路保护可持续,自恢复注:*纹波和噪声的测试方法采用平行线测试法,具体操作方法参见《DC-DC (定压)模块电源应用指南》。

通用特性项目工作条件Min.Typ.Max.单位绝缘电压输入-输出,测试时间1分钟,漏电流小于1mA 1500----VDC输入-输出,测试时间1秒,漏电流小于1mA3000----0.75W ,定电压输入,隔离稳压单路输出专利保护RoHS产品特点●可持续短路保护●空载输入电流低至5mA ●工作温度范围:-40℃to +85℃●效率高达74%●隔离电压1500VDC/min,3000VDC/1s ●国际标准引脚方式●小型SIP 封装●符合UL62368认证●通过EN62368认证IB05_S-W75R3系列产品是专门针对板上电源系统中需要产生一组与输入电源隔离的电压的应用场合而设计的。

施耐德电子产品数据手册-XPSUS12AP防护自动模块特性说明书

施耐德电子产品数据手册-XPSUS12AP防护自动模块特性说明书

T h e i n f o r m a t i o n p r o v i d e d i n t h i s d o c u m e n t a t i o n c o n t a i n s g e n e r a l d e s c r i p t i o n s a n d /o r t e c h n i c a l c h a r a c t e r i s t i c s o f t h e p e r f o r m a n c e o f t h e p r o d u c t s c o n t a i n e d h e r e i n .T h i s d o c u m e n t a t i o n i s n o t i n t e n d e d a s a s u b s t i t u t e f o r a n d i s n o t t o b e u s e d f o r d e t e r m i n i n g s u i t a b i l i t y o r r e l i a b i l i t y o f t h e s e p r o d u c t s f o r s p e c i f i c u s e r a p p l i c a t i o n s .I t i s t h e d u t y o f a n y s u c h u s e r o r i n t e g r a t o r t o p e r f o r m t h e a p p r o p r i a t e a n d c o m p l e t e r i s k a n a l y s i s , e v a l u a t i o n a n d t e s t i n g o f t h e p r o d u c t s w i t h r e s p e c t t o t h e r e l e v a n t s p e c i f i c a p p l i c a t i o n o r u s e t h e r e o f .N e i t h e r S c h n e i d e r E l e c t r i c I n d u s t r i e s S A S n o r a n y o f i t s a f f i l i a t e s o r s u b s i d i a r i e s s h a l l b e r e s p o n s i b l e o r l i a b l e f o r m i s u s e o f t h e i n f o r m a t i o n c o n t a i n e d h e r e i n .Product data sheetCharacteristicsXPSUS12APPreventa module Cat.4 features 2*XPSUAF +enabling movement 24vac/dc screwMainRange of product Preventa Safety automation Product or component typePreventa safety module Safety module name XPSUSSafety module applicationFor electrical monitoring of two-hand control stations Monitoring antivalent contactsFor emergency stop, guard and light curtain monitoringFor enabling switch monitoringFunction of moduleEmergency stop button with 2 NC contacts Guard monitoring with 1 or 2 limit switches Monitoring 2 PNP sensors Magnetic switch monitoring Light curtain monitoring RFID switchMonitoring of electro-sensitive protection equipment (ESPE)Enabling switch monitoring Proximity sensor monitoringMonitoring two-hand control station Safety levelCan reach PL e/category 4 ISO 13849-1Can reach SILCL 3 IEC 62061Can reach SIL 3 IEC 61508Safety reliability dataMTTFd > 30 years ISO 13849-1Dcavg >= 99 % ISO 13849-1PFHd = 1.13E-09 ISO 13849-1HFT = 1 IEC 62061PFHd = 1.13E-09 IEC 62061SFF > 99% IEC 62061HFT = 1 IEC 61508-1PFHd = 1.13E-09 IEC 61508-1SFF > 99% IEC 61508-1Type = B IEC 61508-1Electrical circuit typeNC pair PNP pairAntivalent pair OSSD pairConnections - terminalsRemovable screw terminal block, 0.2...2.5 mm² solid or flexibleRemovable screw terminal block, 0.25...2.5 mm²flexible with ferrule single conductorRemovable screw terminal block, 0.2...1.5 mm² solid or flexible twin conductorRemovable screw terminal block, 2 x 0.25...1 mm²flexible with ferrule without cable end, with bezel Removable screw terminal block, 2 x 0.5...1.5 mm²flexible with ferrule with cable end, with bezel [Us] rated supply voltage24 V AC - 15...10 %24 V DC - 20...20 %ComplementarySynchronisation time between inputs0.5 s 2 s 4 sType of startAutomatic/manual/monitored Power consumption in W 2 W 24 V DCPower consumption in VA 5.0 VA 24 V AC 50/60 Hz Input protection type Internal, electronic Safety outputs2 NOSafety inputs2Maximum wire resistance500 OhmInput compatibility Normally closed circuit ISO 14119XC limit switch ISO 14119Mechanical contact ISO 14119Normally closed circuit ISO 13850Antivalent pair ISO 14119OSSD pair IEC 61496-1-2Two-hand control EN 574/ISO 13851-III A3-wire proximity sensors PNPOutput type Relay output, 250 V ACRelay output, 250 V ACRelay output, 24 V DCRelay output, 24 V DC[Ie] rated operational current5 A AC-13 A AC-155 A DC-13 A DC-133 A AC-11 A AC-153 A DC-11 A DC-13Control outputs 3 pulsed outputInput/output type Semiconductor pulsed diagnostic output Z1, 20 mA [Ith] conventional free air thermal current8 AAssociated fuse rating10 A gG NO relay output circuit IEC 60947-1 Minimum output current10 mA relay outputMinimum output voltage12 V relay outputMaximum response time on input open20 ms[Ui] rated insulation voltage250 V 2)EN/IEC 60947-1[Uimp] rated impulse withstand voltage4 kV II EN/IEC 60947-1Local signalling Power ON LED green)Error LED red)Safety output status LED yellow)Start input LED yellow)Safety input S12 LED yellow)Safety input S13 LED yellow)Safety input S22 LED yellow)Safety input S23 LED yellow)Mounting support35 mm symmetrical DIN railMaximum Depth 4.72 in (120 mm)Maximum Height 3.94 in (100 mm)Maximum Width0.89 in (22.5 mm)Net Weight0.44 lb(US) (0.200 kg)EnvironmentStandards IEC 60947-5-1IEC 61508-1 functional safety standardIEC 61508-2 functional safety standardIEC 61508-3 functional safety standardIEC 61508-4 functional safety standardIEC 61508-5 functional safety standardIEC 61508-6 functional safety standardIEC 61508-7 functional safety standardISO 13849-1 functional safety standardIEC 62061 functional safety standardProduct certifications TÜVCULusIP degree of protection IP20 terminals)EN/IEC 60529IP40 housing)EN/IEC 60529IP54 mounting area)EN/IEC 60529Ambient air temperature for storage-13…185 °F (-25…85 °C)Relative humidity5…95 % non-condensingOrdering and shipping detailsCategory22477 - SAFETY MODULES (PREVENTA)Discount Schedule SAF2GTIN03606489601812Nbr. of units in pkg.1Package weight(Lbs)1 lb(US) (0.45 kg)Returnability YesPacking UnitsUnit Type of Package 1PCEPackage 1 Height 2.56 in (6.5 cm)Package 1 width 5.31 in (13.5 cm)Package 1 Length 6.30 in (16 cm)Unit Type of Package 2BB1Number of Units in Package 21Package 2 Weight11.11 oz (315 g)Package 2 Height 2.52 in (6.4 cm)Package 2 width 5.24 in (13.3 cm)Package 2 Length 6.02 in (15.3 cm)Unit Type of Package 3S03Number of Units in Package 316Package 3 Weight11.57 lb(US) (5.246 kg)Package 3 Height11.81 in (30 cm)Package 3 width11.81 in (30 cm)Package 3 Length15.75 in (40 cm)Offer SustainabilitySustainable offer status Green Premium productEU RoHS Directive Pro-active compliance (Product out of EU RoHS legal scope)EU RoHSDeclarationMercury free YesRoHS exemption information YesChina RoHS Regulation China RoHS DeclarationEnvironmental Disclosure Product Environmental ProfileCircularity Profile End Of Life InformationWEEE The product must be disposed on European Union markets following specificwaste collection and never end up in rubbish bins.PVC free YesDimensions DrawingsDimensionsFront and Side Views(A) :Product drawing(B) :Screw clamp terminal (C) :Side view(1) :Removable terminal blocks, top (2) :Removable terminal blocks, bottom (3) :LED indicators(4) :Start function selector (5) :Function selector(6) :Connector for optional output extension module (lateral)(7) :Sealable transparent coverMounting and Clearance Mounting to DIN railScrew-mountingConnections and SchemaWiring Drawing(1) :A1-A2 (Power supply)(2) :S11-S12-S13-S21-S22-S23 (Single-channel safety input)(3) :Y1-Y2 (Start)13-23-14-24 :OutputEXT :Connector for optional extension module B2 :Common ground terminalZ1 :Pulsed output for diagnostics, not safety-related。

INA193AQDBVRQ1;中文规格书,Datasheet资料

INA193AQDBVRQ1;中文规格书,Datasheet资料

FEATURES APPLICATIONS DESCRIPTIONV –16IN+INA193A-Q1,INA194A-Q1,INA195A-Q1INA196A-Q1,INA197A-Q1,INA198A-Q1 SBOS366C–AUGUST2006–REVISED OCTOBER2008CURRENT SHUNT MONITORS–16-V to+80-V Common-Mode Range•Welding Equipment•Qualified for Automotive Applications•Notebook Computers•Wide Common-Mode Voltage:•Cell Phones–16V to+80V•Telecom Equipment•Low Error:3.0%Over Temperature(Max)•Automotive•Bandwidth:Up to500kHz•Power Management•Three Transfer Functions Available:•Battery Chargers20V/V,50V/V,and100V/V•Complete Current-Sense SolutionThe INA193A–INA198A family of current shunt monitors with voltage output can sense drops across shunts at common-mode voltages from–16V to+80V,independent of the INA19xA supply voltage.They are available with three output voltage scales:20V/V,50V/V,and100V/V.The500-kHz bandwidth simplifies use in current control loops.The INA193A–INA195A provide identical functions but alternative pin configurations to the INA196A–INA198A,respectively.The INA193A–INA198A operate from a single2.7-V to18-V supply.They are specified over the extended operating temperature range(–40°C to125°C),and are offered in a space-saving SOT-23package.Please be aware that an important notice concerning availability,standard warranty,and use in critical applications of TexasInstruments semiconductor products and disclaimers thereto appears at the end of this data sheet.PRODUCTION DATA information is current as of publication date.Copyright©2006–2008,Texas Instruments Incorporated Products conform to specifications per the terms of the Texas12345V+V IN–V IN+GND OUTINA193A INA194A INA195A DBV PACKAGE (TOP VIEW)12345V IN–V IN+V+GND OUTINA196A INA197A INA198A DBV PACKAGE (TOP VIEW)ABSOLUTE MAXIMUM RATINGS (1)INA193A-Q1,INA194A-Q1,INA195A-Q1INA196A-Q1,INA197A-Q1,INA198A-Q1SBOS366C–AUGUST 2006–REVISED OCTOBER This integrated circuit can be damaged by ESD.Texas Instruments recommends that all integrated circuits be handled with appropriate precautions.Failure to observe proper handling and installation procedures can cause damage.ESD damage can range from subtle performance degradation to complete device failure.Precision integrated circuits may be more susceptible to damage because very small parametric changes could cause the device not to meet its published specifications.ORDERING INFORMATION (1)T APACKAGE (2)ORDERABLE PART NUMBER TOP-SIDE MARKING INA193AQDBVRQ1BOG INA194AQDBVRQ1BOH INA195AQDBVRQ1BOI –40°C to 125°CSOT-23–DBVReel of 3000INA196AQDBVRQ1BOJ INA197AQDBVRQ1BOK INA198AQDBVRQ1BOL(1)For the most current package and ordering information,see the Package Option Addendum at the end of this document,or see the website at .(2)Package drawings,standard packing quantities,thermal data,symbolization,and PCB design guidelines are available at /sc/package.over operating free-air temperature range (unless otherwise noted)MINMAX UNIT Supply voltage18V Differential input voltage range,analog inputs (V IN+–V IN–)–1818V Common-mode voltage range (2)–1680V Analog output voltage range (2)OUTGND –0.3(V+)+0.3V Input current into any pin (2)5mA Storage temperature range –65150°C Junction temperature150°C Human-Body Model4000ESD qualification ratingsMachine Model 200VCharged-Device Model1000(1)Stresses beyond those listed under "absolute maximum ratings"may cause permanent damage to the device.These are stress ratings only,and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating conditions"is not implied.Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.(2)Input voltage at any pin may exceed the voltage shown if the current at that pin is limited to 5mA.2Submit Documentation Feedback Copyright ©2006–2008,Texas Instruments IncorporatedELECTRICAL CHARACTERISTICS INA193A-Q1,INA194A-Q1,INA195A-Q1 INA196A-Q1,INA197A-Q1,INA198A-Q1 SBOS366C–AUGUST2006–REVISED OCTOBER2008 V S=12V,V IN+=12V,V SENSE=100mV(unless otherwise noted)Full range T A=–40°C to125°CPARAMETER TEST CONDITIONS T A MIN TYP MAX UNITINPUT(V S–0.2)/V SENSE Full-scale input voltage V SENSE=V IN+−V IN–25°C0.15VGainVCM Common-mode input Full range–1680VV IN+=−16V to+80V25°C8094CMR Common-mode rejection dBV IN+=12V to80V Full range10012025°C±0.52V OS Offset voltage,RTI mVFull range0.53dV OS/dT Offset voltage vs temperature Full range 2.5µV/°COffset voltage vs V S=2.7V to18V,PSR Full range5100µV/V power supply V IN+=18VI B Input bias current V IN–pin Full range±8±23µA OUTPUT(V SENSE≥20mV)INA193A,INA196A20G Gain INA194A,INA197A25°C50V/VINA195A,INA198A10025°C±0.2±1 Gain error V SENSE=20mV to100mV%Full range±225°C±0.75±2.2 Total output error(1)%Full range±1±3 Nonlinearity error V SENSE=20mV to100mV25°C±0.002±0.1%R O Output impedance25°C 1.5ΩMaximum capacitive load No sustained oscillation25°C10nF OUTPUT(V SENSE<20mV)(2)–16V≤V CM<0300All devices mVV S<V CM≤80V300INA193A,0.4INA196AV OUT Output voltage25°CINA194A,0V≤V CM≤V S,1VINA197A V S=5VINA195A,2INA198AVOLTAGE OUTPUT(3)Swing to V+power-supply rail R L=100kΩto GND Full range V+–0.1V+–0.2VSwing to GND(4)R L=100kΩto GND Full range V GND+3V GND+50mV(1)Total output error includes effects of gain error and V OS.(2)For details on this region of operation,see Accuracy Variations as a Result of V SENSE and Common-Mode Voltage in ApplicationsInformation.(3)See Typical Characteristics curve Output Swing vs Output Current.(4)Specified by designCopyright©2006–2008,Texas Instruments Incorporated Submit Documentation Feedback3INA193A-Q1,INA194A-Q1,INA195A-Q1INA196A-Q1,INA197A-Q1,INA198A-Q1SBOS366C–AUGUST2006–REVISED ELECTRICAL CHARACTERISTICS(continued)V S=12V,V IN+=12V,V SENSE=100mV(unless otherwise noted)Full range T A=–40°C to125°CPARAMETER TEST CONDITIONS T A MIN TYP MAX UNIT FREQUENCY RESPONSEINA193A,500INA196AINA194A,BW Bandwidth C LOAD=5pF25°C300kHzINA197AINA195A,200INA198APhase margin C LOAD<10nF25°C40°SR Slew rate1V/µsV SENSE=10mV to100mV PP,t s Settling time(1%)25°C2µsC LOAD=5pFNOISE,RTIVoltage noise density25°C40nV/√Hz POWER SUPPLYV S Operating voltage Full range 2.718VV OUT=2V Full range7001250INA193A,INA194A,370950I Q Quiescent current INA196A,µAV SENSE=0mV Full rangeINA197AINA195A,3701050INA198ATEMPERATURE RANGEOperating temperature–40125°CStorage temperature–65150°CθJA Thermal resistance200°C/W4Submit Documentation Feedback Copyright©2006–2008,Texas Instruments IncorporatedTYPICAL CHARACTERISTICS4540353025201510510k100k G a i n (d B )Frequency (Hz)1M4540353025201510510k 100k G a i n (d B )Frequency (Hz)1M140130120110100908070605040101001k10k C o m m o n -M o d e a n d P o w e r -S u p p l y R e j e c t i o n (d B )Frequency (Hz)100k2018161412108642020100200300400500600700V O U T (V )V DIFFERENTIAL (mV)8009004.03.53.02.52.01.51.00.50050100150200250300350O u t p u t E r r o r (%e r r o r o f t h e i d e a l o u t p u t v a l u e )V (mV)SENSE 4004505000.10.090.080.070.060.050.040.030.020.01041282016O u t p u t E r r o r (%)Common-Mode Voltage (V)...7680INA193A-Q1,INA194A-Q1,INA195A-Q1INA196A-Q1,INA197A-Q1,INA198A-Q1 SBOS366C–AUGUST 2006–REVISED OCTOBER 2008T A =25°C,V S =12V,V IN+=12V,and V SENSE =100mV (unless otherwise noted)GAIN GAIN vsvsCOMMON-MODE and POWER-SUPPLY REJECTIONvsGAIN PLOTFREQUENCYOUTPUT ERROROUTPUT ERRORvs vsV SENSECopyright ©2006–2008,Texas Instruments Incorporated Submit Documentation Feedback 5121110987654321005101520O u t p u t V o l t a g e (V )Output Current (mA)25301000900800700600500400300200100001234567I (µA )Q Output Voltage (V)8910343026221814106O u t p u t S h o r t -C i r c u i t C u r r e n t (m A )Supply Voltage (V)18875775675575475375275175–16–12–8–4048121620I (µA )Q V (V)CM 7680...O u t p u t V o l t a g e (50 m V /d i v )Time (2 µs/div)G =20V = 10 mV to 20 mVSENSE Time (2 µs/div)G =20O u t p u t V o l t a g e (500 m V /d i v )V = 10 mV to 100 mVSENSE INA193A-Q1,INA194A-Q1,INA195A-Q1INA196A-Q1,INA197A-Q1,INA198A-Q1SBOS366C–AUGUST 2006–REVISED OCTOBER TYPICAL CHARACTERISTICS (continued)T A =25°C,V S =12V,V IN+=12V,and V SENSE =100mV (unless otherwise noted)POSITIVE OUTPUT VOLTAGE SWINGQUIESCENT CURRENTvsvsOUTPUT VOLTAGEQUIESCENT CURRENTOUTPUT SHORT-CIRCUIT CURRENTvsvsCOMMON-MODE VOLTAGESUPPLY VOLTAGE6Submit Documentation Feedback Copyright ©2006–2008,Texas Instruments IncorporatedTime (2 µs/div)G =20O u t p u t V o l t a g e (50 m V /d i v )V = 90 mV to 100 mVSENSE Time (5 µs/div)G =50O u t p u t V o l t a g e (100 m V /d i v )V = 10 mV to 20 mVSENSE Time (5 µs/div)G =50O u t p u t V o l t a g e (1V /d i v )V = 10 mV to 100 mVSENSE Time (5 µs/div)G =50O u t p u t V o l t a g e (100 m V /d i v )V = 90 mV to 100 mVSENSE Time (10 µs/div)G =100O u t p u t V o l t a g e (2V /d i v )V = 10 mV to 100 mVSENSE INA193A-Q1,INA194A-Q1,INA195A-Q1INA196A-Q1,INA197A-Q1,INA198A-Q1 SBOS366C–AUGUST 2006–REVISED OCTOBER 2008TYPICAL CHARACTERISTICS (continued)T A =25°C,V S =12V,V IN+=12V,and V SENSE =100mV (unless otherwise noted)STEP RESPONSESTEP RESPONSERESPONSECopyright ©2006–2008,Texas Instruments Incorporated Submit Documentation Feedback 7APPLICATION INFORMATIONBasic ConnectionV IN+–16I Power SupplyAccuracy Variations as a Result of V SENSE and Common-Mode VoltageINA193A-Q1,INA194A-Q1,INA195A-Q1INA196A-Q1,INA197A-Q1,INA198A-Q1SBOS366C–AUGUST 2006–REVISED OCTOBER Figure 1shows the basic connection of the INA19xA.The input pins,V IN+and V IN–,should be connected as closely as possible to the shunt resistor to minimize any resistance in series with the shunt resistance.Power-supply bypass capacitors are required for stability.Applications with noisy or high-impedance power supplies may require additional decoupling capacitors to reject power-supply noise.Connect bypass capacitors close to the device pins.Figure 1.INA19xA Basic ConnectionThe input circuitry of the INA19xA can accurately measure beyond its power-supply voltage,V+.For example,the V+power supply can be 5V,whereas the load power-supply voltage is up to 80V.The output voltage range of the OUT terminal,however,is limited by the voltages on the power-supply pin.The accuracy of the INA193A–INA198A current shunt monitors is a function of two main variables:V SENSE (V IN+–V IN–)and common-mode voltage,V CM ,relative to the supply voltage,V S .V CM is expressed as (V IN++V IN–)/2;however,in practice,V CM is seen as the voltage at V IN+because the voltage drop across V SENSE is usually small.8Submit Documentation Feedback Copyright ©2006–2008,Texas Instruments IncorporatedNormal Case 1:V SENSE ≥20mV,V CM ≥V SG +V OUT1*V OUT2100mV *20mV (1)V OS RTI (Referred−To−Input)+ǒV OUT1G Ǔ*100mV(2)Normal Case 2:V SENSE ≥20mV,V CM <V SLow V SENSE Case 1:V SENSE <20mV,–16V ≤V CM <0;and Low V SENSE Case 3:V SENSE <20mV,INA193A-Q1,INA194A-Q1,INA195A-Q1INA196A-Q1,INA197A-Q1,INA198A-Q1 SBOS366C–AUGUST 2006–REVISED OCTOBER 2008This section addresses the accuracy of these specific operating regions:Normal Case 1:V SENSE ≥20mV,V CM ≥V S Normal Case 2:V SENSE ≥20mV,V CM <V SLow V SENSE Case 1:V SENSE <20mV,–16V ≤V CM <0Low V SENSE Case 2:V SENSE <20mV,0V ≤V CM ≤V S Low V SENSE Case 3:V SENSE <20mV,V S <V CM ≤80VThis region of operation provides the highest accuracy.Here,the input offset voltage is characterized and measured using a two-step method.First,the gain is determined by (Equation 1).Where:V OUT1=Output voltage with V SENSE =100mV V OUT2=Output voltage with V SENSE =20mVThe offset voltage is then measured at V SENSE =100mV and referred to the input (RTI)of the current shunt monitor,as shown in (Equation 2).In the Typical Characteristics,the Output Error vs Common-Mode Voltage curve shows the highest accuracy for the this region of operation.In this plot,V S =12V;for V CM ≥12V,the output error is at its minimum.This case is also used to create the V SENSE ≥20mV output specifications in the Electrical Characteristics table.This region of operation has slightly less accuracy than Normal Case 1as a result of the common-mode operating area in which the part functions,as seen in the Output Error vs Common-Mode Voltage curve.As noted,for this graph V S =12V;for V CM <12V,the Output Error increases as V CM becomes less than 12V,with a typical maximum error of 0.005%at the most negative V CM =–16V.V S <V CM ≤80VAlthough the INA193A–INA198A family of devices are not designed for accurate operation in either of these regions,some applications are exposed to these conditions;for example,when monitoring power supplies that are switched on and off while V S is still applied to the INA193A–INA198A.It is important to know what the behavior of the devices will be in these regions.As V SENSE approaches 0mV,in these V CM regions,the device output accuracy degrades.A larger-than-normal offset can appear at the current shunt monitor output with a typical maximum value of V OUT =300mV for V SENSE =0mV.As V SENSE approaches 20mV,V OUT returns to the expected output value with accuracy as specified in the Electrical Characteristics.Figure 2illustrates this effect using the INA195A and INA198A (Gain =100).Copyright ©2006–2008,Texas Instruments Incorporated Submit Documentation Feedback 92.01.81.61.41.21.00.80.60.40.20024681012141618V O U T (V )V SENSE (mV)20Low V SENSE Case 2:V SENSE <20mV,0V ≤V CM ≤V S2.42.22.01.81.61.41.21.00.80.60.40.200246810121416182022V O U T (V )V SENSE (mV)24NOTE:(1)INA193,INA196V OUT Tested Limit =0.4V.INA194,INA197V OUT Tested Limit =1V.INA193A-Q1,INA194A-Q1,INA195A-Q1INA196A-Q1,INA197A-Q1,INA198A-Q1SBOS366C–AUGUST 2006–REVISED OCTOBER Figure 2.Example for Low V SENSE Cases 1and 3(INA195A,INA198A:Gain =100)This region of operation is the least accurate for the INA193A–INA198A family.To achieve the wide input common-mode voltage range,these devices use two op amp front ends in parallel.One op amp front end operates in the positive input common-mode voltage range,and the other in the negative input region.For this case,neither of these two internal amplifiers dominates and overall loop gain is very low.Within this region,V OUT approaches voltages close to linear operation levels for Normal Case 2.This deviation from linear operation becomes greatest the closer V SENSE approaches 0V.Within this region,as V SENSE approaches 20mV,device operation is closer to that described by Normal Case 2.Figure 3illustrates this behavior for the INA195A.The V OUT maximum peak for this case is tested by maintaining a constant V S ,setting V SENSE =0mV and sweeping V CM from 0V to V S .The exact V CM at which V OUT peaks during this test varies from part to part,but the V OUT maximum peak is tested to be less than the specified V OUT tested limit.Figure 3.Example for Low V SENSE Case 2(INA195A,INA198A:Gain =100)10Submit Documentation Feedback Copyright ©2006–2008,Texas Instruments Incorporated分销商库存信息: TIINA193AQDBVRQ1。

福建力得温控仪LDB系列说明书

福建力得温控仪LDB系列说明书

目录1.技术指标........................................................................ 错误!未指定书签。

1.1 基本技术参数..................................................... 错误!未指定书签。

1.2 标准................................................................... 错误!未指定书签。

2.功能与型号分类............................................................ 错误!未指定书签。

3.显示.............................................................................. 错误!未指定书签。

4.传感电缆总成................................................................ 错误!未指定书签。

4.1 D25传感电缆(三线制) .................................... 错误!未指定书签。

4.2 传感器.................................................................. 错误!未指定书签。

5.操作与显示.................................................................... 错误!未指定书签。

5.1 温控器工作状态显示 .......................................... 错误!未指定书签。

5.2 按键功能.............................................................. 错误!未指定书签。

HEF4069资料

HEF4069资料

DATA SHEETProduct specificationFile under Integrated Circuits, IC04January 1995HEF4069UB gatesHex inverterFor a complete data sheet, please also download:•The IC04 LOCMOS HE4000B Logic Family Specifications HEF, HEC •The IC04 LOCMOS HE4000B LogicPackage Outlines/Information HEF, HECHex invertergatesDESCRIPTIONThe HEF4069UB is a general purpose hex inverter. Eachof the six inverters is a single stage.Fig.1 Functional diagram.HEF4069UBP(N):14-lead DIL; plastic(SOT27-1)HEF4069UBD(F):14-lead DIL; ceramic (cerdip)(SOT73)HEF4069UBT(D):14-lead SO; plastic(SOT108-1)( ): Package Designator North AmericaFig.2 Pinning diagram.Fig.3 Schematic diagram (one inverter).FAMILY DATA, I DD LIMITS category GATESSee Family Specifications for V IH/V IL unbuffered stagesHex invertergatesAC CHARACTERISTICSV SS=0 V; T amb=25°C;C L= 50 pF; input transition times≤20 nsV DD V SYMBOL TYP.MAX.TYPICAL EXTRAPOLATION FORMULAPropagation delays54590ns18ns+(0,55 ns/pF) C LI n→O n10t PHL2040ns9ns+(0,23 ns/pF) C LHIGH to LOW151525ns7ns+(0,16 ns/pF) C L54080ns13ns+(0,55 ns/pF) C L LOW to HIGH10t PLH2040ns9ns+(0,23 ns/pF) C L151530ns7ns+(0,16 ns/pF) C L Output transition times560120ns10ns+(1,0 ns/pF) C LHIGH to LOW10t THL3060ns9ns+(0,42 ns/pF) C L152040ns6ns+(0,28 ns/pF) C L560120ns10ns+(1,0 ns/pF) C LLOW to HIGH10t TLH3060ns9ns+(0,42 ns/pF) C L152040ns6ns+(0,28 ns/pF) C LV DDVTYPICAL FORMULA FOR P (µW)Dynamic power5600 f i+∑(f o C L)×V DD2wheredissipation per10 4 000 f i+∑(f o C L)×V DD2f i=input freq. (MHz) package (P)1522 000 f i+∑(f o C L)×V DD2f o=output freq. (MHz)C L=load capacitance (pF)∑ (f o C L)=sum of outputsV DD=supply voltage (V)Hex invertergatesFig.4Typical transfer characteristics;___ V O;___I D(drain current);I O=0; V DD=5 V.Fig.5Typical transfer characteristics;___ V O;___I D(drain current);I O=0; V DD=10 V.Fig.6Typical transfer characteristics;___ V O;___I D(drain current);I O=0; V DD=15 V.Hex invertergatesAPPLICATION INFORMATIONSome examples of applications for the HEF4069UB are shown below.In Fig.7 an astable relaxation oscillator is given. The oscillation frequency is mainly determined by R1C1, provided R1<<R2 and R2C2<<R1C1.Fig.7(a) Astable relaxation oscillator using two HEF4069UB inverters; the diodes may be BAW62; C2 is a parasitic capacitance. (b) Waveforms at the points marked A, B, C and D in the circuit diagram.The function of R2 is to minimize the influence of the forward voltage across the protection diodes on the frequency; C2 is a stray (parasitic) capacitance.The period T p is given by T p =T 1+T 2,in whichV ST is the signal threshold level of the inverter. The period is fairly independentof V DD , V ST and temperature. The duty factor, however, is influenced by V ST .T 1R1C1In V DD V ST +V ST ----------------------------and T 2R1C1In 2V DD V ST–V DD V ST–---------------------------------where==(a)(b)Hex invertergatesFig.8 Crystal oscillator for frequencies up to 10 MHz, using two HEF4069UB inverters.(1)This inverter is added to amplify theoscillator output voltage to a levelsufficient to drive other LOCMOS circuits.Fig.9Voltage gain (V O /V I ) as a function of supply voltage.Fig.10 Supply current as a function of supply voltage.Fig.11Test set-up for measuring graphs of Figs 9and 10.It is also an example of an analogue amplifier using one HEF4069UB.Hex invertergatesFig.12Test set-up for measuring forward transconductance g fs =di o /dv i at v o is constant (see also graphFig.13).Fig.13 Typical forward transconductance g fs as a function of the supply voltage at T amb =25°C.A :average,B :average + 2 s,C :average −2 s, where:‘s’ is the observed standard deviation.。

cd4069中文资料_数据手册_参数

cd4069中文资料_数据手册_参数

NS 14 2000 Green (RoHS & no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM -55 to 125
NS 14 2000 Green (RoHS & no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM -55 to 125
PW
14
90 Green (RoHS
(5) Multiple Device Markings will be inside parentheses. Only one Device Marking contained in parentheses and separated by a "~" will appear on a device. If a line is indented then it is a continuation of the previous line and the two combined represent the entire Device Marking for that device.
ACTIVE TSSOP
ACTIVE
CDIP
D
14
50 Green (RoHS
& no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM -55 to 125
D
14 2500 Green (RoHS CU NIPDAU | CU SN Level-1-260C-UNLIM -55 to 125
Copyright 2003, Texas Instruments Incorporated
PACKAGE OPTION ADDENDUM

ADG406中文资料

ADG406中文资料
VS = +5 V VS = 0 V, RS = 0 Ω, CL = 1 nF; Test Circuit 10 RL = 1 kΩ, f = 100 kHz; VEN = 0 V, Test Circuit 11 RL = 1 kΩ, f = 100 kHz, Test Circuit 12 f = 1 MHz f = 1 MHz
APPLICATIONS Audio and Video Routing Automatic Test Equipment Data Acquisition Systems Battery Powered Systems Sample Hold Systems Communication Systems Avionics
VIN = 0 or VDD f = 1 MHz
RL = 300 Ω, CL = 35 pF; V1 = ± 10 V, V2 = ϯ10 V; Test Circuit 5 RL = 300 Ω, CL = 35 pF; VS = +5 V, Test Circuit 6 RL = 300 Ω, CL = 35 pF; VS = +5 V, Test Circuit 7 RL = 300 Ω, CL = 35 pF; VS = +5 V, Test Circuit 7
Test Conditions/Comments
ANALOG SWITCH Analog Signal Range RON
RON Match
LEAKAGE CURRENTS Source OFF Leakage IS (OFF) Drain OFF Leakage ID (OFF) ADG406, ADG426 ADG407 Channel ON Leakage ID, IS (ON) ADG406, ADG426 ADG407

tmi4054技术规格书

tmi4054技术规格书

tmi4054技术规格书TM4054 技术规格书概述TM4054 是一款高性能、低功耗的步进电机驱动器,采用TM4054 控制芯片。

该驱动器专为单极性和双极性步进电机而设计,具有高扭矩、低噪音和低振动的特点。

特性支持单极性和双极性步进电机最高驱动电流为 4.0A细分分辨率高达 256 倍8 种可调微步模式保护功能:过流、过压、欠压、短路保护内置 PWM 发生器可选的 UART 接口尺寸:100mm x 67mm x 30mm规格电气特性电源电压范围:12V-48V驱动电流:0.5A-4.0A(可调)细分分辨率:1-256 倍微步模式:全步、半步、1/4 步、1/8 步、1/16 步、1/32 步、1/64 步、1/128 步、1/256 步PWM 频率:20kHz-50kHz(可调)机械特性尺寸:100mm x 67mm x 30mm重量:约 200g安装方式:螺钉安装环境特性工作温度范围:-20℃ 至+50℃存储温度范围:-40℃ 至+85℃湿度范围:0% 至 90%(无冷凝)接口电源端子:接电源正负极电机端子:连接步进电机控制端子:接控制信号,包括脉冲、方向、使能可选的 UART 接口:用于通过串口进行配置和控制应用TM4054 步进电机驱动器广泛应用于各种工业自动化和运动控制应用,包括:CNC 机器3D 打印机机器人自动化设备医疗器械安装安装驱动器前,请确保电源已断开。

将驱动器安装在平坦且牢固的表面上,并确保有足够的散热空间。

连接电源、电机和控制线。

按照说明书中的步骤配置驱动器。

配置TM4054 步进电机驱动器可以通过其 UART 接口或使用 DIP 开关进行配置。

有关配置的详细说明,请参阅用户手册。

维护定期检查驱动器是否有灰尘或污垢堆积,并根据需要进行清洁。

避免在潮湿或极端温度条件下使用驱动器。

如果驱动器发生故障,请将其送回授权服务中心进行维修。

继电器样本

继电器样本
2.2产 品 顶 部 有 工 作 状 态 指 示 灯 及产品接线图,请按照接线图正确接线。安装方式为导轨式安装, 可安装在RTR35导轨上。 2.3外 形尺寸 见 图1、 图2、 图3, 内 部接 线 见 图4。
3 型号含义
4 技术参数
输入
额定输入电压
动作电压 返回电压 动作时间 返回时间
输出
最大切换电压 最大切 换电流(阻性负载) 最大 切 换 功 率(阻 性 负 载) 最高动作频率 触点材料
如需要其他规格可按用户要求单独订做继电耦合器返回电压返回时间输入动作电压额定输入电压动作时间最大切换电压最大切换功率阻性负载最高动作频率触点材料测试耐压使用寿命绕组触点机械寿命触头触点电气寿命dc12v24v48v60v110v220vac24v48v110v220v250vac30vdc2kva25kva4kva1800次小时银合金4技术参数输出最大切换电流阻性负载8a10a16a安装方式rtr35环境安装方式107105res72rx支架式设计序号工作环境温度1055储藏温度污染等级257022工作原理和结构继电耦合器用于各种自动保护和自动控制线路作为输出继电器或增加保护和控制回路触点的数量和容量
订货号
767068 767061 767077 767097 767101 767063 767102 767103 767107 767059 767108 767051 767047 767098 767062 767099 767100 767104 767064 767105 767106 767109 767057 767110 767053 767049 767086 767082 767072 767078 767080 767079 767076 767075 767052 767048 767054 767055 767085 767074 767081 767067

纽豹 RFID 工厂产品手册说明书

纽豹 RFID 工厂产品手册说明书

RFID 工厂产品手册天线生产INLAY封装复合与层压个人化目录目录电子标签生产一站式完整解决方案RFID生产力复合个人化软件解决方案RFID 生产力RFID工厂/2020概念天线生产ACS 100/350APS 100/350 Inlay 封装直接贴片技术TAL 15000DDA 20000 / DDA 40000小载条技术DDA 20000 / DDA 40000 - Strap 复合CL light CL 30000 CL 60000个人化PL lightPL 30000 PL 60000661010 12141516182021222426283032343637373839纽豹专长于创新的一站式解决方案开发,包括生产、个人化、电子护照发行、身份证件和其他相关安全性文件的发行和全自动通关控制系统。

Tecurity ®定制的安全解决方案包括广泛的定制安全解决方案项目的开发。

在过去的30年里,超过100个高成熟性的生产设备加上生产管理和个人化的智能软件方案构成了自动化部门的核心。

除了身份识别证件、智能卡和RFID电子标签生产的一站式解决方案之外,我们也生产创新型芯片分拣设备用于半导体行业。

纽豹集团的精密零件与系统部门不但为本公司提供高精度的零部件,同时我们的产品还用于诸如航空航天、汽车马达、医疗工程和半导体等重要的工业领域。

软件MB incape MB PalaMax®世界生产中心豹已经成长为技术创新型合作伙伴,不断为客户提供更优化的系统。

我们致力于整合生产流程并确保纽豹集团的核心竞争力在于自主生产的精密零部件、对机械和电子、工艺流程和软件等的不断提 全球总部LMCiCiiBiiiKBiiGDiVDVFNHieDiiiDiiDiBiCiii CiV目录研发与工艺工程质量保证与流程控制精密零部件生产培训与专业技术中心 展示与演示间 包装与运输仓储 大型特殊零件生产系统组装软件与电子工程机械工程半导体后道与 RFID生产中心 全球服务与支持一站式解决方案供应商端到端系统综合解决方案纽豹集团是唯一全球化 的智能卡、电子护照、半导体全套生产设备和方案供应商。

AD202JY,AD202JN,AD202KY,AD202KN,AD204JY,AD204JN,AD204KN,AD204KY, 规格书,Datasheet 资料

AD202JY,AD202JN,AD202KY,AD202KN,AD204JY,AD204JN,AD204KN,AD204KY, 规格书,Datasheet 资料
The functional block diagrams can be seen in Figures 1a and 1b.
PRODUCT HIGHLIGHTS The AD202 and AD204 are full-featured isolators offering numerous benefits to the user:
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781/329-4700

Fax: 781/326-8703
© Analog Devices, Inc., 2002
芯天下--/
Isolated Power: The AD204 can supply isolated power of ± 7.5 V at 2 mA. This is sufficient to operate a low-drift input preamp, provide excitation to a semiconductor strain gage, or power any of a wide range of user-supplied ancillary circuits. The AD202 can supply ± 7.5 V at 0.4 mA, which is sufficient to operate adjustment networks or low power references and op amps, or to provide an open-input alarm.
Small Size: The AD202 and AD204 are available in SIP and DIP form packages. The SIP package is just 0.25" wide, giving the user a channel density of four channels per inch. The isolation barrier is positioned to maximize input to output spacing. For applic, the DIP package provides a height of just 0.350".

LDD-A406NI中文资料

LDD-A406NI中文资料

|
Product Seh Engine
|
Tech Notes
|
Sales and Tech Support
|
Corporate Info
290 East Helen Road Palatine, IL 60067 Telephone: (847) 359-2790 Facsimile: (847) 359-8904 E-mail us at sales@ © 1997-2001 Lumex, Inc.
Image next to part no. indicates cad file. Indicates an Opto Express part.
q
Product Table Applications Options Order Samples Stock/Price Request Sales and Tech Support Drawings
元器件交易网
LEDs, LCDs, SMTs, Opto-Couplers and Displays from Lumex, Inc.
.39" Dual Numeric Displays
INDEX
q q q q q q
PRODUCT TREE 1. Product Gallery 2. LED Displays and Chips on Board Light Bars 3. .28"-.80" Character Numeric & Alpha-Numeric Displays/Single, Dual & Quad 4. .39" Dual Numeric Displays
Green Yellow Red Sup Red Green Yellow Red Sup Red

深圳市英锐芯电子科技有限公司950mA线性锂离子电池充电器AD4056数据手册说明书

深圳市英锐芯电子科技有限公司950mA线性锂离子电池充电器AD4056数据手册说明书

950mA线性锂离子电池充电器AD4056 AD4056简介数据手册版本V1.0950mA线性锂离子电池充电器AD4056芯片功能说明:实物图:ØAD4056是一款完整的单节锂离子电池采用恒定电流/恒定电压线性充电器。

其底部带有散热片的SOP8封装与较小的外部元件数目使得AD4056成为便携式应用的理想选择。

AD4056可以适合USB电源和适配器电源工作。

Ø采用了内部PMOSFET架构,加上防倒充电路,所以不需要外部隔离二极管。

热反馈可对充电电流进行自动调节,以便在大功率操作或高环境温度条件下对芯片温度加以限制。

充电电压固定与4.2V,而充电电流可通过一个电阻器进行外部设置。

当充电电流在达到最终浮充电压之后降至设定值1/10时,AD4056将自动终止充电循环。

Ø当输入电压(交流适配器或USB电源)被拿掉时,AD4056自动进入一个低电流状态,将电池漏电流降至2uA以下。

AD4056在有电源时也可至于停机模式,已而将供电电流降至55uA。

AD4056的其他特点包括电池温度检测、欠压闭锁、自动再充电和两个用于指示充电结束的LED状态引脚。

芯片功能主要特性:Ø高达950mA的可编程充电电流Ø无需MOSFET、检测电阻器或隔离二极管Ø用于单节锂离子电池、采用ESOP-8封装的完成线性充电器Ø恒定电流/恒定电压操作,并具有可在无过热危险的情况下实现充电速率最大化的热调节功能Ø精度达到±1%的4.2V预设充电电压Ø用于电池电量检测的充电电流监控器输出Ø自动再充电ØC/10充电终止,灯全灭Ø 2.9V涓流充电器件版本Ø软启动限制了浪涌电流Ø电池温度检测功能Ø待机模式下的供电电流为55uA 芯片基本应用:Ø移动电话PDAØMP3、MP4播放器Ø数码相机Ø电子词典ØGPSØ便携式设备、各种充电器完整的充电循环(1180mAh电池):950mA 线性锂离子电池充电器AD4056结构框图绝对最大额定值Ø输入电源电压(V CC ):-0.3~5.5V ØPROG :-0.3~V CC +0.3V ØBAT :-0.3~5VØ——————CHRG :-0.3~5V Ø————————STDBY :-0.3~5VØTEMP :-0.3~5VØCE :-0.3~5VØBAT 短路持续时间:无短路保护ØBAT 引脚电流:950mA ØPROG 引脚电流:1200uA Ø最大结温:145℃Ø工作环境温度范围:-40℃~85℃Ø贮存温度范围:-65℃~125℃Ø引脚温度(焊接时间10秒):260℃电话:*************82568883邮箱:**********************深圳市英锐芯电子科技有限公司950mA线性锂离子电池充电器AD4056电特性:凡表注●表示该指标适合整个工作温度范围,否则仅指T A=25℃.V CC=5V,除非特别注明。

詠真實業 LDX-405 四回

詠真實業 LDX-405 四回

LDX-405四回路LED調光器【使用手冊】詠真實業股份有限公司網址: Email:*******************.tw目錄第一章 系統簡介 (1)1-1 特點 (1)1-2 規格 (1)1-3 操作面板功能簡介 (1)第二章系統操作說明 (2)2-1 內建模式的設定與呼叫 (2)2-2 設備區域的設定 (2)2-3 ID NO.的設定 (3)2-4 設定場景對應各內建模式 (4)2-5 DMX控制設定 (4)2-6 內建跳級的SPEED調整設定 (5)2-7 DMX位址的設定 (5)2-8 單回路LEVEL查看與自定顏色的設定 (5)2-9 智慧模式的選定 (6)2-10 紅外遙控面板上的設置 (8)2-12.各內建模式如下表 (9)保證說明 (11)第一章系統簡介1-1特點◆可輸出4個控制回路。

◆模組化設計、維護更加容易。

◆可接收標準DMX512訊號控制。

◆ LED顯示介面,操作更加簡單。

◆可接受紅外線遙控面板控制。

◆可接受ECP系列面板控制。

1-2 規格◆電源供應: 12 - 36V DC◆輸出規格:每回路可輸出5A◆數位信號輸入: DMX512◆傳輸速率: 250K bps◆數位信號連接頭: 3PIN綠色端子◆外觀尺寸:228 ( W ) X 60 ( H ) X 40 ( D ) mm◆重量:0.3kg1-3 操作面板功能簡介1 2 3 4 5 6 7 8 (1)DMX IN ( 3 pin ) (5) MODE(6) SETUP(2) 紅外線接收擴展口( 3 pin )(包裝中附紅外線接收頭)(3) UP (7) POWER INPUT(4) DOWN (8) OUTPUT第二章 系統操作說明2-1 內建模式的設定與呼叫STEP-1 按下【MODE 】一次,進入選擇內建模式介面,STEP-2 使用【STEP-3 按下【注意: LDX-405共有33種內建模式,請參考2-12。

4064用户使用说明书

4064用户使用说明书
控制模块隔离:当总线上至少有一个控制模块被隔离本灯亮。
从机故障:所扩接的报警器(JB-QB-508、JB-LGZ-YBZ2032等)出现故障本灯亮。
功能板故障:所接控制单元出现故障本灯亮。
区显故障:当总线上至少有一个区域显示器出现故障本灯亮。
主机故障:PC机出现故障本灯亮
首次火警:用于显示首次火警地址(无火警时显示时间)。
火警总数:用于显示发生火警的数量。
反馈总数:用于显示控制模块收到反馈信号的数量。
7.2按键说明
自检:对数码管及面板上全部指示灯进行测试。
消声:消除声响,火警时关闭警铃继电器和外部讯响器。
7.3多线联动说明
7.3.1指示灯说明
故障:当继电器发生短路、断路时本灯亮。
启动:当报警器当前向联动设备输出启动信号时本灯亮。
10.1.18“编辑/删除”:此选项用于删除直线、矩形、圆、字符、汉字、设备图形。操作:在需删除的图形上按鼠标左键。
10.1.19“编辑/全删除”:此选项用于删除整幅平面图。
10.1.20“编程/图形”: 允许用户选择一设备图形。分为网络方式和单机方式。网络方式下可以画多个CAN总线设备,单机方式下只允许画一个CAN总线设备(4064)。选择此项后,屏幕显示图形菜单,其中包括4064、2032、508、中继器、灭火盘、广播盘、显示器、多线控制、手动键盘、烟探测器、温探测器、光探测器、手动按钮、主模块、输入模块、消防按钮、控制模块、卷帘半降、卷帘全降、排烟机、送风机、水泵、广播、电梯、灭火区、消防广播等。其中,灭火盘只能联动灭火区,并且最大只能联动4个灭火区,广播盘只能联动消防广播。多线控制只能联动控制模块。操作:将鼠标移至所需设备名上按左键,提示消失,再按左键,将显示设备图形,移动鼠标至适当位置,按左键则确定该设备的位置。移动过程中,按空格键可放大或缩小图形。另外还允许用户根据工程的需要自定义设备图形。操作:先选中自定义图标,弹出一个对话框,根据提示分别输入自定义图标的汉字名称和英文简称,(前提是先画好自定义的设备图形,规格:大小分别为16×16和11×11,颜色为16色,并将其拷贝到C:\SYSTEM目录中)按取消按钮则放弃设置,按下确定按钮则保存设置,再按下选中按钮则可以画此设备。自定义设备图标的数量为:探测器最多为3个,控制模块最多为3个。

德派森电气火灾探测器设计使用说明书

德派森电气火灾探测器设计使用说明书

德派森电气火灾探测器
设计使用说明书
一、概述
DPS-T系列漏电探测器采用高导磁率合金材料的铁芯,和绕在铁芯上的二次线圈组成检测元件,并内置集成信号滤波、整流电路模块,共同完成微电流的精密探测。

动力相线或照明电源相线和中性线穿过内孔成为DPS-T漏电传感器的一次线圈。

传感器的后部出线即为保护范围。

DPS-T系列探测器既可与DPS系列智能控制模块配合独立安装于线路。

广泛适用于AC660V及以下TT、TN和IT系统,作为漏电接地故障保护使用。

二、特点
1. 采用基准剩余电流式电气火灾监控探测器DPS(可扩展/K,W);
2. 过流、过压、欠压表象特征量W系列探测;
3. 有8个模拟量的采集数据,1位置继电器DC24V控制输出保留;
4. 设置“报警,不切断电路”和“报警,切断电路”K系可逆选型;
5. 现场可编程,并允许特征量进行修改;
6. 独立单片机,响应速度快,功能科扩展;
7. 通讯功能:采用标准的RS485通讯协议;
8. 额定工作电压:DC24V,取自消防电源或后台主机电源;
9. 总线模式:通讯单总线和二总线模式,电源二总线模式;
10.其他设置:正常、报警和故障显示设置,功能复位设置;
11.专利权类:K输出设计;W接入设计;数字信号输出设计;造型设计;紧固设计等;
三、技术特性
四、结构特征
五、接线方式。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
相关文档