Always use a power supply that complies with IEC/EN60950-1 or IEC/EN61010-1 standard and limited-energy circuitΒιβλιοθήκη requirements.
Operation
Always read the technical data thoroughly (See chapter 6 Technical data).
- Machinery Directive 2006/42/EC - Regulation (EC) No 1935/2004 - Low Voltage Directive (LVD) 2014/35/EU - EMC Directive 2014/30/EU - RoHS2 Directive 2011/65/EU
Title
Kolding
Place
2017-03-01
Date
Lars Kruse Andersen
Name
Signature
4
2 Safety
Unsafe practices and other important information are emphasised in this manual. Warnings are emphasised by means of special signs. All warnings in the manual are summarised on this page. Pay special attention to the instructions below in order to avoid serious personal injury or damage to the top unit.
3
1 EC Declaration of Conformity
Revision of Declaration of Conformity: 2013-12-03
The Designated Company
Alfa Laval Kolding A/S
Company Name
Albuen 31, DK-6000 Kolding, Denmark
Address
+45 79 32 22 00
Phone No.
hereby declare that Actuator with integrated control for butterfly valve
Designation
Unique Control
Type
is in conformity with the following directive with amendments:
2.1 Important information
Always read the manual before using the Unique Control! WARNING Indicates that special procedures must be followed to avoid serious personal injury. CAUTION Indicates that special procedures must be followed to avoid damage to the Unique Control. NOTE Indicates important information to simplify or clarify procedures.
!
Never touch the valve or the pipelines when processing hot liquids or when sterilising.
Never touch the coupling between the valve body and the actuator if compressed air is supplied to the actuator.
Always handle lye and acid with great care.
Transportation
Always make sure that compressed air is released. Always make sure that all connections are disconnected before attempting to remove the valve from the installation. Always drain liquid out of valves before transportation. Always used predesignated lifting points if defined. Always ensure adequate fixing of the valve during transportation - if specially designed packaging material is available it must be used.
The person authorised to compile the technical file is the signer of this document
Global Product Quality Manager Pumps, Valves, Fittings and Tank Equipment
Instruction Manual
Unique Control for Butterfly Valves
ESE02126-EN5
Original manual
2017-03
2109-0039
Table of contents
The information herein is correct at the time of issue but may be subject to change without prior notice
2.2 Warning signs
General warning:
Danger of electrical voltage:
Caustic agents:
2.3 Safety precautions
Installation
Always read the technical data thoroughly (See chapter 6 Technical data).
1. EC Declaration of Conformity ....................................................................... 4 2. Safety .................................................................................................... 5
!
Always release compressed air after use.
Never touch the coupling between the valve body and the actuator if compressed air is supplied to the actuator.
2.1. Important information ............................................................................. 5 2.2. Warning signs ..................................................................................... 5 2.3. Safety precautions ................................................................................ 5 2.4. Loss of air supply ................................................................................. 6 3. General information ................................................................................... 7 3.1. General information ............................................................................... 7 4. Installation .............................................................................................. 8 4.1. Overview of installation instructions ............................................................. 8 4.2. Product dimensions .............................................................................. 9 4.3. Mounting bracket kit on the actuator - step 1 ................................................. 10 4.4. Mounting actuator on the valve head - step 2 ................................................. 11 4.5. Connecting the air supply- step 3 ............................................................... 12 4.6. Connecting the communication cable- step 4 ................................................. 13 4.7. Calibration- step 5 ................................................................................ 16 4.8. Changing NC/NO functionality .................................................................. 17 4.9. Recycling information ............................................................................. 19 5. Troubleshooting ....................................................................................... 20 5.1. Actuator position marking misaligned .......................................................... 20 6. Technical data ......................................................................................... 22 6.1. Technical data ..................................................................................... 22 7. Parts list ............................................................................................... 24 7.1. Parts list ............................................................................................ 24
相关文档
最新文档