罗德施瓦茨FSH3说明书
RSPF系列产品说明书
ContentsDescription Page Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2Manual introduction . . . . . . . . . . . . . . . . . . . . . .2Product overview . . . . . . . . . . . . . . . . . . . . . . . .2Safety precautions . . . . . . . . . . . . . . . . . . . . . . .2RSPF series catalog number . . . . . . . . . . . . . . . . .3RSPF series product nameplate . . . . . . . . . . . . . .3Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4Pre-installation checklist . . . . . . . . . . . . . . . . . . .4Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4Wiring diagrams . . . . . . . . . . . . . . . . . . . . . . . . .6Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6Power up and system checkout . . . . . . . . . . . . .6Alarm silence pushbutton . . . . . . . . . . . . . . . . .6Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . .6Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7Liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7Ordering guidelines . . . . . . . . . . . . . . . . . . . . . . . .8References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8Appendix A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9PRL3 provision kit . . . . . . . . . . . . . . . . . . . . . . .9PRL4 provision kit 1 of 2 . . . . . . . . . . . . . . . . .10PRL4 provision kit 2 of 2 . . . . . . . . . . . . . . . . .11Installation instructions for Eaton RSPF seriessurge protective device (SPD)2Instruction Leaflet IL158004ENEffective September 2023Installation instructions for Eaton RSPF seriessurge protective device (SPD)EATON IntroductionManual introductionThis installation manual describes the installation and operation of the Eaton RSPF series surge protective device (SPD) . This technical document covers most aspects of installation and operation . This document is a guide only for licensed/qualifiedelectricians . If you require further information regarding a particular installation, application, or maintenance activity, please contact your Eaton representative . These instructions do not cover all details, variations or combinations of the equipment, its storage, delivery, installation, check-out, safe operation or maintenance . Care must be exercised to comply with local, state, and national regulations, as well as safety practices for this class of equipment .Please read and understand all installation and operating instructions prior to installation and use of this equipment.Product overviewThe Eaton RSPF series SPD protects critical electrical and electronic equipment from damage by voltage transients and surges when properly installed . This is done by shunting high-energy lightning surges (and other transient disturbances) away from the equipment being protected . It does this in nanoseconds by providing a low-impedance surge path to ground through thermally protected metal oxide varistors while supporting power frequency voltage . Proper installation is critical to ensure the SPD operates as intended .The Eaton RSPF series SPD was designed and developed to fit in the space of an Eaton F-/PD2-frame molded case circuit breaker for retrofit into existing panelboards or switchboards with space or provisions for an additional F-/PD2-frame molded case circuit breaker .This device features internal protection that will disconnect the surge protective component under fault conditions but will maintain power to the load, now unprotected from surge events .The Eaton RSPF series SPD is available in voltage ratings from 208 Vac to 600 Vac and surge current ratings of 50 kA and 100 kA . The enclosure measures 6 .00 x 4 .13 x 3 .81 inches (152 .4 x 104 .8 x 96 .7 mm) with a maximum weight of ~3 lb (~1 .36 kg) .The Eaton RSPF series is available in nine options . See Ordering guidelines on page 8 for more details .Safety precautions3Instruction Leaflet IL158004ENEffective September 2023Installation instructions for Eaton RSPF seriessurge protective device (SPD) EATON RSPF series catalog numberEach Eaton RSPF series SPD is identified by a catalog number, see example in T able 1 . The catalog number identifies the parameters that make up the unit .T able 1. Catalog numbering systemFor example, an RSPF series SPD with a catalog number of RSPF2403MA1A-K3, where:RSP = RSP series F = Surge frame 240 = Voltage code3 = Number of phases MA = Type and current rating of panel1 = Feature package A= ApplicationK3 = Optional panelboard provision kitSee Ordering guidelines on page 8 for additional voltages, features, and service options .RSPF series product nameplateEach Eaton RSPF series SPD has a product nameplate affixed to the front of the unit that identifies the catalog number and operating parameters . The catalog number consists of letters and numbers that identify the RSPF series, surge frame, voltage code, number of phases, panel bus rating, feature package, and application as shown in Figure 1 .Figure 1. RSPF series product nameplateRSP F 240 3 MA 1 A - K3Provision kit Application FeaturePanel busPhase VoltageFrameSeries4Instruction Leaflet IL158004ENEffective September 2023Installation instructions for Eaton RSPF seriessurge protective device (SPD)EATON InstallationPre-installation checklist•Does the panelboard have a 3-pole F-/PD2-frame breaker space available?•Does the panelboard have a panel with an opening that will allow the front of an RSPF series SPD to protrude through after installation?•Does the panelboard have 3-pole F-/PD2-frame phase connectors?If the answer is ‘Y es’ to all three previously listed statements, then the RSPF catalog number will NOT require an optional provision kit . If the answer is ‘No’ to any of the three previous statements, then an optional provision kit ‘- K3’ or ‘- K4’ will need to be included in the RSPF catalog number .1. Select a space to the mount the SPD as close to the incomingpower terminations as possible for optimum performance .2. Confirm that the system voltage is the same as the RSPF seriesSPD that you are installing .3. Check the facility grounding system . All grounding, bonding, andearthing must meet the NEC, CEC, and any other national, state, and local electrical codes .4. The installation consists of mounting and verifying the SPD’sconnections and torque settings on the line-side provision bus and the surge ground terminal .5. Check to ensure the area is clear of dirt, debris, or clutter thatmay hamper the installation .WarningMounting1. Locate the electrical system’s applicable block diagram inWiring diagrams section on page 6 .2. Turn OFF power to the electrical panel that the SPD is beingconnected to in accordance with NEC, CEC, state, county, and local codes for all safety ratings .3. Confirm no voltage is present before continuing .4. Remove the panelboard’s trim/door to assist with installation .5. Remove the four panel mounting screws where the SPD will bemounted . Then remove the black plastic fillers where the SPD will be located . If the existing panel has no openings and is being replaced with a new panel from a connector kit, then discard/recycle the old panel (see Figure 2) .Figure 2. Remove panel6. Remove any accessories that could impede the removalof the rails and panels, such as breaker padlockable handles and/or interlocks .7. Remove the four silver rail mounting screws located in the fourcorners shown in Figure 3 to remove the remaining panels andrails as one complete assembly .5Instruction Leaflet IL158004ENEffective September 2023Installation instructions for Eaton RSPF seriessurge protective device (SPD)EATON Figure 3. Remove panel and rails8. If installing a new PRL3 or PRL4 provision kit, do so nowfollowing the instructions provided (see Appendix A ) .9. View of a panelboard PRL3a with panels and rails removedshowing the phase connectors installed just above the F-/PD2-frame breaker (see Figure 4) .Figure 4. PRL3a with connector kit installed10. Place the RSPF SPD in the panelboard as close to the incomingpower terminations for optimum performance . Mount the RSPF to the bus using the hardware provided in the connector kit . Torque to 35 lb-in (3 .16 N·m) (see Figure 5) .Figure 5. SPD installed—terminal side11. The RSPF series SPD’s surge ground terminal can be wired toeither the ground bar or the neutral bar, whichever bar is closest to the SPD .a. When wiring to the ground bar, preferred method, usea green or green with yellow stripe #10 AWG insulatedconductor . Keep the wire length as short as possible . Torque the surge ground terminal screw to 35 lb-in (3 .16 N·m) (see Figure 6) .b. When wiring to the neutral bar, use a white #10 AWGinsulated conductor . Keep the wire length as short as possible . Torque the surge ground terminal screw to 35 lb-in (3 .16 N·m) .Figure 6. SPD installed—surge ground terminal12. After the SPD has been installed, check all mounting hardware,line terminal hardware, and the surge ground terminal for correct torque loading .13. Re-install the rails and panel assembly using the four silver railscrews . Torque the hardware according to the manufacturer’s specifications .14. Re-install any breaker interlocks or accessories .15.Mount the panel over the SPD .6Instruction Leaflet IL158004ENEffective September 2023Installation instructions for Eaton RSPF seriessurge protective device (SPD)EATON 16. Apply the “Protected by Eaton Surge Protective Device (SPD)Catalog No . RSPFxxxxxxxx” label to the left or right of the SPD (see Figure 7) .Figure 7. Apply label provided with SPD 17. Replace the panelboard’s trim/door .Wiring diagramsFigure 8. Surge ground terminal connected to the ground busFigure 9. Surge ground terminal connected to the neutral busOperationPower up and system checkoutSwitch main panel power to ON . The green LED should light to indicate the phase voltage is being monitored .If the red LED lights, remove power and contact the EatonCareTechnical Resource Center at 1-800-809-2772, option 5, sub-option 2, as the SPD may be damaged .If neither LED lights, remove power, check connections, and test again . Verify that the proper voltage is present . If the panel isenergized properly and the LEDs still do not light, contact EatonCare Technical Resource Center at 1-800-809-2772, option 5, sub-option 2, as the SPD may be damaged .Alarm silence pushbuttonThe RSPF SPD has an alarm silence pushbutton located below the red LED on the front of the SPD . The alarm will sound when the red LED indicates that the SPD has lost one or more phases of protection . To silence the alarm after loss of protection, press and hold the alarm silence pushbutton for at least 1 second . If the alarm silence pushbutton does not silence the alarm, contact EatonCare Technical Resource Center at 1-800-809-2772, option 5, sub-option 2, as the SPD may be damaged .SpecificationsT able 2. SpecificationsDescriptionSpecificationkA per phase50 (on units with filtering), 100Nominal discharge current (I n )20 kASystem voltages240 = 120/208Y, 127/220Y, 240D480 = 220/380Y, 230/400Y, 240/415Y, 277/480Y, 480D600 = 347/600Y, 600D Short-circuit current rating 200 kA Input power frequency 50/60 Hz Protection modesWye L–N, L–L Delta L–G, L–LOperating temperature –40 °F to +140 °F (–40 °C to +60 °C)Relative humidity 5%–95%, noncondensing Maximum altitude 6561 ft (2000 m)Weight~3 lb (~1.36 kg)Certification/listingUL T 1449 5th Edition, CSA T 269.1-17269.2-17, C22.2 No. 8-13 EMI Filter Tested to UL 1283 6th EditionSPD typeUL 1449 5th Edition and CSA type 1 and type 2 SPD RoHS compliant YesEnclosureIndoor use only Designed and tested in accordance with the most recent version of these standards:IEEE T C62.41.1IEEE C62.41.2IEEE C62.43IEEE C62.45IEEE C62.48IEEE C62.627Instruction Leaflet IL158004ENEffective September 2023Installation instructions for Eaton RSPF seriessurge protective device (SPD) EATON MaintenanceThe RSPF series SPD is a self-contained device that requires no maintenance and contains no serviceable parts . If the red LED is illuminated, the unit has lost one or more modes of surge protection and must be replaced . Please contact your localauthorized distributor or EatonCare Technical Resource Center at 1-800-809-2772, option 5, sub-option 2 for additional information and technical assistance, as the SPD may be under warranty .LiabilityThis instruction leaflet is published solely for information purposes and should not be considered all-inclusive . If further information is required, you should consult EatonCare Technical Resource Center at 1-800-809-2772, option 5, sub-option 2 . Sale of the productshown in this literature is subject to terms and conditions outlined in appropriate Eaton selling policies or other contractual agreements between the parties . This literature is not intended to and does not enlarge or add to any such contract . The sole source governing the rights and remedies of any purchaser of this equipment is thecontract between the purchaser and Eaton .In no event will Eaton be responsible to the purchaser or user in contract, in tort (including negligence), strict liability or otherwise for any special, indirect, incidental or consequential damage, or loss whatsoever, including but not limited to damage or loss of equipment use, plant or power system, cost of capital, loss of power, additional expenses in the use of existing power facilities or claims against the purchaser or user by its customers resulting from the use of the information, recommendations, and description contained herein .8Instruction Leaflet IL158004ENEffective September 2023Installation instructions for Eaton RSPF seriessurge protective device (SPD)EATON Ordering guidelinesT able 3. RSP catalog numbering systema Omit if provision kit is not needed.ReferencesProvision kits contain phase connectors, deadfront cover, filler covers, hardware, and instruction sheet . Contact the EatonCare Technical Resource Center at 1-800-809-2772, option 5,sub-option 2, to order the appropriate connector kit listed below for the intended installation .The following references are available at www .eaton .com .• Current Eaton panelboards—Renewal parts RP01400001E •Eaton renewal parts data—Panelboard renewal parts supplement RP01414001E•Vintage Cutler-Hammer panelboards and switchboards— Renewal parts RP01400003E•Vintage Westinghouse panelboards —Renewal parts RP01400002EWarrantyEaton warrants the RSPF series SPD to be free from defects in both workmanship and materials for a period of 2 years from shipment . To register the product, go to www .eaton .com/RSP and click on the warranty registration icon .Eaton assumes no risk or liability for results of the use of the product purchased, including but not limiting the generality of the foregoing:(1) The use in combination with any electrical or electroniccomponents, circuits, systems, assemblies, or any other materials or substances .(2) Unsuitability of any product for use in any circuit or assembly .Purchaser’s rights under the warranty shall consist solely of requiring Eaton to repair, or at Eaton’s sole discretion, replace, free of charge, F .O .B . factory, any defective items received at said factory within said term determined by Eaton to be defective . The giving of or failure to give any advice or recommendations by Eaton shall not constitute any warranty by or impose any liability upon Eaton AND IS IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESSED, IMPLIED OR STATUTORY AS TO THE MERCHANTABILITY , FITNESS FOR PURPOSE SOLD, PRODUCTIVENESS, OR ANY OTHER MATTER . In no event shall Eaton be liable for special or consequential damages or for delay in performance of the warranty .This warranty does not apply if the unit has been misused, abused, altered, tampered with, or applied in excess of the specifications other than those written on the nameplate . At the end of thewarranty period, Eaton shall be under no further warranty obligation expressed or implied .The Eaton RSPF series SPD covered by this warranty certificate can only be repaired or replaced by the factory . A RETURN MATERIAL AUTHORIZATION (RMA) number must be obtained . Please enter a Vista warranty claim or contact CORE (Center of Returns Excellence) at 1-800-410-2910 for help with entering a claim or to obtain an update on your claim status . Repair or replacement will be returned collect . If it is determined that the returned product contains manufacturer’s defects, then Eaton will replace the defective product at Eaton’s expense (including shipping charge) .RSP F 240 3 MA 1 A – K3SeriesRSP = RSP series Surge frameF = F framePhase3 = 3-phaseApplicationA = Direct BUS mountedVoltage code options240 = 120/208Y, 127/220Y, 240D 480 = 220/380Y, 230/400Y, 240/415Y, 277/480Y, 480D 600 = 347/600Y, 600DType and current rating of panel optionsMA = Main service up to 2000 A, 100 kA per phase SA = Sub-panel up to 800 A, 50 kA per phaseSB = Sub-panel greater than 800 A, 100 kA per phaseFeature package options1 = Basic (available with SB and MA )2 = Basic plus filtering (available with SA only)Provision kit aK3 = Provision kit for PRL3A panelboard K4 = Provision kit for PRL4A panelboard9Instruction Leaflet IL158004ENEffective September 2023Installation instructions for Eaton RSPF seriessurge protective device (SPD) EATON Appendix APRL3 provision kit10Instruction Leaflet IL158004ENEffective September 2023Installation instructions for Eaton RSPF seriessurge protective device (SPD)EATON PRL4 provision kit 1 of 211Instruction Leaflet IL158004EN Effective September 2023Installation instructions for Eaton RSPF seriesEATON Eaton1000 Eaton Boulevard Cleveland, OH 44122 United StatesEaton .com© 2023 EatonAll Rights ReservedPrinted in USAPublication No . IL158004EN / Z27895 September 2023Eaton is a registered trademark.All other trademarks are propertyof their respective owners.Installation instructionsfor Eaton RSPF series surge protective device (SPD)Instruction Leaflet IL158004ENEffective September 2023For additional information, please call:Eaton’s Power Quality Technical Support1-800-809-2772, option 5, sub-option 2.。
Xofigo 放射性治疗药剂指南说明书
UnitedHealthcare ® Medicare AdvantagePolicy GuidelineXofigo ® Radioactive Therapeutic AgentGuideline Number : MPG356.09Approval Date : November 8, 2023 Terms and ConditionsTable of Contents Page Policy Summary ............................................................................. 1 Applicable Codes .......................................................................... 1 References ..................................................................................... 2 Guideline History/Revision Information ....................................... 2 Purpose .......................................................................................... 3 Terms and Conditions . (3)See PurposeOverviewXofigo ® (radium Ra 223 dichloride) injection is an alpha particle-emitting radioactive therapeutic agent which mimics calcium and forms complexes with hydroxyapatite at areas of increased bone turnover, such as bone metastases.GuidelinesThe U.S. Food and Drug Administration (FDA) approved radium Ra 223 dichloride (Xofigo ® Injection, Bayer HealthCare Pharmaceuticals Inc.) for the treatment of patients with castration-resistant prostate cancer (CRPC), symptomatic bonemetastases and no known visceral metastatic disease.The recommended dose and schedule for Xofigo ® is 55 kBq/kg (1.49 microcuries/kg) administered by slow intravenous injection over 1 minute every 4 weeks for 6 doses.The following list(s) of procedure and/or diagnosis codes is provided for reference purposes only and may not be all inclusive. Listing of a code in this guideline does not imply that the service described by the code is a covered or non-covered health service. Benefit coverage for health services is determined by the member specific benefit plan document and applicable laws that may require coverage for a specific service. The inclusion of a code does not imply any right to reimbursement or guarantee claim payment. Other Policies and Guidelines may apply.CPT Code Description 79101 Radiopharmaceutical therapy, by intravenous administrationCPT ® is a registered trademark of the American Medical AssociationHCPCS Code DescriptionA9606 Radium RA-223 dichloride, therapeutic, per microcurieDiagnosis Code DescriptionC61Malignant neoplasm of prostateRelated Medicare Advantage Reimbursement Policy • Add-on Codes Policy, ProfessionalDiagnosis CodeDescriptionAnd at least one of the following:C79.51 Secondary malignant neoplasm of boneC79.52 Secondary malignant neoplasm of bone marrowCMS Local Coverage Determinations (LCDs) and ArticlesLCDArticleContractor Medicare Part A Medicare Part BN/A A54559 Billing and Coding: Xofigo Billing Instructions PalmettoAL, GA, NC, SC,TN, VA, WV N/AA55052 Billing and Coding: Radiopharmaceutical Agents Retired 12/29/2022WPSAK, AL, AR, AZ, CA, CO, CT, DE, FL, GA, HI, IA, ID, IL, IN, KS, KY, LA, MA, MD, ME, MI, MO, MS, MT, NC, ND, NE, NH, NJ, NM, NV, OH, OK, OR, PA, RI, SC, SD, TN, TX, UT, VA, VT, WA, WI, WV, WYIA, IN, KS, MI, MO, NECMS Benefit Policy ManualChapter 15; § 50 Drugs and BiologicalsCMS Claims Processing ManualChapter 12; § 30.5 Payment for Codes for Chemotherapy Administration and Nonchemotherapy Injections and Infusions Chapter 14; § 10 General Ambulatory Surgical CenterChapter 17; § 90.2 Drugs, Biologicals, and RadiopharmaceuticalsOther(s)CGS Website (Submitting Claims for Xofigo/Radium 223)CMS HCPCS Codes for which ASP Reporting is in Units of Measure Other Than an NDC, Updated July 2023, CMS Website Xofigo Package Insert, Bayer Healthcare Pharmaceuticals WebsiteRevisions to this summary document do not in any way modify the requirement that services be provided and documented in accordance with the Medicare guidelines in effect on the date of service in question.Date Summary of Changes11/08/2023Policy Summary OverviewRemoved and relocated language pertaining to the U.S. Food and Drug Administration (FDA)approval of radium Ra 223 dichloride (Xofigo ® Injection, Bayer HealthCare Pharmaceuticals Inc.) usage (refer to the Guidelines section) GuidelinesRevised language to indicate:Date Summary of Changeso The U.S. Food and Drug Administration (FDA) approved radium Ra 223 dichloride (Xofigo®Injection, Bayer HealthCare Pharmaceuticals Inc.) for the treatment of patients with castration-resistant prostate cancer (CRPC), symptomatic bone metastases and no known visceralmetastatic diseaseo The recommended dose and schedule for Xofigo® is 55 kBq/kg (1.49 microcuries/kg)administered by slow intravenous injection over 1 minute every 4 weeks for 6 dosesSupporting InformationUpdated References section to reflect the most current informationArchived previous policy version MPG356.08The Medicare Advantage Policy Guideline documents are generally used to support UnitedHealthcare Medicare Advantage claims processing activities and facilitate providers’ submission of accurate claims for the specified services. The document can be used as a guide to help determine applicable:Medicare coding or billing requirements, and/orMedical necessity coverage guidelines; including documentation requirements.UnitedHealthcare follows Medicare guidelines such as NCDs, LCDs, LCAs, and other Medicare manuals for the purposes of determining coverage. It is expected providers retain or have access to appropriate documentation when requested to support coverage. Please utilize the links in the References section above to view the Medicare source materials used to develop this resource document. This document is not a replacement for the Medicare source materials that outline Medicare coverage requirements. Where there is a conflict between this document and Medicare source materials, the Medicare source materials will apply.The Medicare Advantage Policy Guidelines are applicable to UnitedHealthcare Medicare Advantage Plans offered by UnitedHealthcare and its affiliates.These Policy Guidelines are provided for informational purposes, and do not constitute medical advice. Treating physicians and healthcare providers are solely responsible for determining what care to provide to their patients. Members should always consult their physician before making any decisions about medical care.Benefit coverage for health services is determined by the member specific benefit plan document* and applicable laws that may require coverage for a specific service. The member specific benefit plan document identifies which services are covered, which are excluded, and which are subject to limitations. In the event of a conflict, the member specific benefit plan document supersedes the Medicare Advantage Policy Guidelines.Medicare Advantage Policy Guidelines are developed as needed, are regularly reviewed and updated, and are subject to change. They represent a portion of the resources used to support UnitedHealthcare coverage decision making. UnitedHealthcare may modify these Policy Guidelines at any time by publishing a new version of the policy on this website. Medicare source materials used to develop these guidelines include, but are not limited to, CMS National Coverage Determinations (NCDs), Local Coverage Determinations (LCDs), Medicare Benefit Policy Manual, Medicare Claims Processing Manual, Medicare Program Integrity Manual, Medicare Managed Care Manual, etc. The information presented in the Medicare Advantage Policy Guidelines is believed to be accurate and current as of the date of publication and is provided on an "AS IS" basis. Where there is a conflict between this document and Medicare source materials, the Medicare source materials will apply.You are responsible for submission of accurate claims. Medicare Advantage Policy Guidelines are intended to ensure that coverage decisions are made accurately based on the code or codes that correctly describe the health care services provided. UnitedHealthcare Medicare Advantage Policy Guidelines use Current Procedural Terminology (CPT®), Centers for Medicare andMedicaid Services (CMS), or other coding guidelines. References to CPT® or other sources are for definitional purposes only and do not imply any right to reimbursement or guarantee claims payment.Medicare Advantage Policy Guidelines are the property of UnitedHealthcare. Unauthorized copying, use, and distribution of this information are strictly prohibited.*For more information on a specific member's benefit coverage, please call the customer service number on the back of the member ID card or refer to the Administrative Guide.。
FSH中文说明书
· 3天(室温25-32 度) 各种分析仪均适用的情况: ·根据要求进行标定:如质控结果超出范围时。
试剂: M:链霉亲和素包被的微粒(透明瓶盖),1瓶,6.5ml。粒子浓度0.72mg/ml,
生物素结合能力: 470ng生物素/mg粒子。含防腐剂。 R1:生物素化的抗FSH单克隆抗体(灰盖),1瓶,10ml。浓度2.0mg/l,MES
• 绝¾ø经后
181
67,0
LH/FSH比值(从育龄期妇女的标本中测算出来):
卵泡期: 0.82(n=315)
黄体期: 1.12(n=279)
如有必要各实验室应自己测定一个参考值范围。
25,8
134,8
霉亲和素间的反应结合到微粒上。
Elecsys1010:
· 第3步:反应混和液吸到测量池中,微粒通过磁铁吸附到电极上,未结合的 · 每一试剂盒做一次
物质被清洗液洗去,电极加电压后产生化学发光,通过光电倍增管进行测定。 · 7天(室温20-25 度)
·检测结果由机器自动从标准曲线上查出。此曲线由仪器通过2点定标校正, 由从试剂条形码扫描入仪器的原版标准曲线而得。
· Elecsys 通用质控品(PreciControl)货号11731416 · Elecsys1010、2010或E170分析仪 Elecsys1010/2010分析仪需要 · Elecsys系统缓冲液(ProCell)货号11662988 · Elecsys 测量池清洗液(CleanCell)货号11662970 · Elecsys 添加剂液(SysWash)货号11930346 · Elecsys 系统清洗液支架(Adapter for SysClean) )货号11933159
含沉淀的标本使用前需离心。
RF Coaxial Connectors 产品目录说明书
AEROspaceAUTOMOTIVEDEFENSEINDUSTRIALINSTRUMENTATIONSPACETELECOMMEDICAL101, Rue Ph. Hoffmann93116 ROSNY sous BOIS (Paris)Tel.: +33 1 49 35 35 35 - Fax: +33 1 48 54 63 63 E-Mail: info @P.O. Box 202 - 90101 OULU Tel.: +358 407 522 412 E-Mail: infofi @Carl-Zeiss Str. 10 Postfach 200143 D63307 - RÖDERMARK (Frankfurt)Tel.: +49 60 74 91 07 0 - Fax: +49 60 74 91 07 70 E-Mail: infode @Via Concordia, 5 - 20090 ASSAGO MILANO Tel.: +39 02 48 85 121 - Fax: +39 02 48 84 30 18 E-Mail: infoit @ Regional office: RomaHogebrinkerweg 15b - 3871 KM HOEVELAKEN Tel.: +31 33 253 40 09 - Fax: +31 33 253 45 12 E-Mail: infonl @Sjöängsvägen 2 - SE-192 72 SOLLENTUNA (Stockholm) Tel.: +46 844 434 10 - Fax: +46 875 449 16 E-Mail: infose @Ground Floor, 6 The Grand Union Office Park, Packet Boat LaneUXBRIDGE Middlesex UB8 2GH (London)Tel.: +44 1895 425 000 - Fax: +44 1895 425 010 E-Mail: infouk @6825 West Galveston Street CHANDLER, Arizona 85226Tel.: +1 480 682 9400 - Fax: +1 480 682 9403 E-Mail: infousa @N° 390 Yong He Road 200072 - SHANGHAITel.: +86 21 66 52 37 88 - Fax: +86 21 66 52 11 77 E-Mail: infosh @Shibuya-ku Ebisu 1-5-2, Kougetsu Bldg 405 TOKYO 150-0013Tel.: +81 3 3440 6241 - Fax: +81 3 3440 6242 E-Mail: infojp @Flat D, 6/F Ford Glory Plaza, 37-39 Wing Hong Street Cheung Sha WanKOWLOON HONG KONGTel: +852-2959-3833 - Fax:+852-2959-2636 E-Mail: infohk @25 D, II Phase, Peenya Industrial Area BANGALORE 560058Tel.: +91 80 83 95 271 - Fax: +91 80 83 97 228 E-Mail: infoin @For the above countries, please contact the local agent or RADIALL at info @ALSO REPRESENTED INRadiall Navigator ™ is a tool designed to assist our partners and customers that provides instant access to the right information at the right moment. This tool is intended to make sharing information about Radiall products as easy as possible in one single document.With this in mind, we have created Radiall Navigator as a supplemental guide toinformation available in our catalogs and on our website (). We recognize that time is a very limited and valuable asset. We are confident that Radiall Navigator will help users understand our products, terminologies, and references better.FerruleAttACHmENtBuLkHEAD FEEDTHROugH (Panel jack and receptacle)FLANgE MOuNT(Square, rectangular, round; panel jack and receptacle)THROugH-HOLE PINS (Also available: Surface Mount = SMT and Press-fit; PCB receptacle)FASTENINgAND MOuNTINgATTACHMENT METHODCLAMP TyPE ON FLExIBLE CABLE The center contact is solderedCRIMP TyPE ON FLExIBLE CABLEThe center contact can be either soldered or crimpedSOLDER TyPE ON SEMI-RIgID AND CONFORMABLE CABLEThe center contact is solderedSOLDER TyPE ON PCBThrough-hole pins or surface mount (SMT)COuPLINgPlugJackSCREW-ON INTERFACESMA, SMC, TNC, N, UHF, DIN 7/16, etc.) excellent performance, • long termination time, needs space SNAP-ON INTERFACEUMP, MMS, MMT, MC-Card, SMB, MCX, average performance,• very fast termination time, space saving, perfect for miniaturization SLIDE-ON INTERFACEBMA, SMP "smooth bore," excellent performance, very fast • termination time, space saving, outer latching mechanism BAyONET INTERFACEBNC, C, average performance, fast termination time and needs space • AuTOMATIC LATCHINg INTERFACEQMA, QN, SMB "Fakra and USCar,"SMZ type 43, average performance, • very fast termination time, spacesaving, secured matingFemaleRight AngleStraightORIENTATIONRF Coaxial Connectors3 digits correspond to series(SMA, BNC, SMB, etc; refer to finder guide for series)3 digits correspond to function(Interface, geometry, panel mounting, etc.)3 digits correspond to variant(Dimension, finish, packaging, etc.)4 digits correspond to series(SMA, BNC, SMB, etc; refer to finder guide for series)4 digits correspond to(Plating, captivation, attachment and materials)3 digits correspond to variant(Variation)Radiall Part Number System Radiall AEP Part Number SystemPCB Mount?right angle?PlugJackpanel, box or PCB。
罗德与施瓦茨公司 频谱分析仪 产品手册
R&S®FSL频谱分析仪重量极轻, 高性能,结构紧凑测试与测量产品手册|5.1罗德与施瓦茨R&S®FSL频谱分析仪1¸FSL 是在该级别仪器中具有最宽的解调带宽和最佳 RF 特性的全功能频谱分析仪。
2R&S®FSL 频谱分析仪一览¸FSL 是一台重量极轻且结构紧凑的分析仪,适合在开发、维护和生产中的大量应用中使用。
尽管它体积很小,却提供了高端仪器才具有的大量功能,因而具有出色的性价比。
¸FSL 是在该级别中唯一的一种具有高达6 GHz 的跟踪源的仪器,可以对具有28 MHz 带宽的信号进行I/Q 解调。
除此之外, ¸FSL 的工作频率范围可达18 GHz, 适用于微波频段高端功能也体现在其操作特点上。
与高端频谱仪一样,¸FSL 的主要功能可直接通过固定分配的功能键进行访问,而附加功能可通过软键和表格进行访问。
这样就缩短了新用户学习使用仪器的时间。
紧凑的设计、极轻的重量以及可选的内置电池,使得¸FSL 适合于移动使用。
¸FSL 具有独特的即插即用升级能力。
所有选件可以不打开仪器而添加进来。
主要特点频率范围9 kHz 至3 GHz/6 GHz/18 GHz 3 GHz/6 GHz 产品可选配跟踪源同类产品中最佳射频性能同类产品中最大I/Q 解调带宽28 MHz 即使在微波频段也具有很高的测量精度由于全数字运算而具有很高的滤波器精度结构坚固而紧凑便携提手和很轻的重量(<8 kg/18 lbs )可选择电池供电操作功能广泛,操作简单易于在现场升级J J J J J J J J J J J 现在,您在购买频谱分析仪时无需再在价格和功能二者之间进行折衷了。
您不必增加预算,就能购买到具有高端性能的仪器 — ¸FSL 。
R&S®FSL频谱分析仪优势及主要特点同类产品中优异的性能从9 kHz到18 GHz连续射频范围和28 MHz解调带宽即是在微波频段也有低的测量不确定度灵活快速的用于生产高测量速度节省了时间提高了效率通过LAN或IEC/IEEE总线进行符合SCPI标准的远程控制用于实验室研发极高的性价比满足信号分析的通用目的对于各种无线/数字蜂窝标准具有广泛的测量功效轻便紧凑的结构,便于现场安装维护和操作尺寸小重量轻,易于便携可选内部电池实现无电源线操作支持NRP-Zxx探头进行功率测量接口多样,升级简便所有选件的安装都可以不打开仪器附加接口扩展了FSL的应用范围功能广泛-易于操作拥有广泛的测量功能,具备高端频谱分析仪的特点内置测量程序和多种可选择的固件选件JJJJJJJJJJJJJJ罗德与施瓦茨R&S®FSL频谱分析仪34该级别中性能最为优异的仪器偏离载波10 kHz 处的相位噪声典型值为-103 dBc (1 Hz),三阶互调截止点典型值为+18 dBm, 10 Hz 至10 MHz 的中频带宽范围,以及-162 dBm 的 平均显示噪声电平 (DANL),所有这些都使¸FSL 能够与高端分析仪相匹敌。
FFR-动脉生理检测仪中文说明书
生理学鉴定界面动脉生理检测仪使用说明书产品名称:动脉生理检测仪(商品名:RadiAnalyzer Xpress)规格型号:12711生产商:Radi Medical Systems AB地址:Palmbladsgatan 10, SE-754 50 Uppsala, Sweden电话:+46 (0) 18 16 10 00注册证号:国食药监械(进)字2008第3213570号(更)产品标准号:YZB/SWE 4995-2008售后服务机构:圣犹达医疗用品(上海)有限公司售后服务机构地址:上海市外高桥保税区富特西一路439号01号楼1层邮编:200130电话:(86)21-2306-7588传真:(86)21-6422-4838RadiAnalyzer XpressRoHS有毒有害物质或元素部件名称铅(Pb) 汞(Hg)镉(Cd)六价铬(Cr(VI))多溴联苯(PBB)多溴二苯醚(PBDE)主板X O O O O OPC-104X O O O O O绝缘材料,红色O O X O O O PIN针O O X O O O PIN针O(X)O O O O内部线缆红色X O O(X; Cr) O O内部线缆红色O O O O(X; Br) (X; Br) 塑料部件O O O O(X; Br) (X; Br) 螺钉O O-(X;Cr)O OO:表示该有毒有害物质在该部件所有均质材料中的含量均在SJ/T11363-2006 标准规定的限量要求以下。
Pb,Hg,Cr(VI),PBB,PBDE的浓度极限:1000ppmCd的浓度极限:100ppmX:表示该有毒有害物质至少在该部件的某一均质材料中的含量超出SJ/T11363-2006 标准规定的限量要求。
(X):表示被提及的元素在定期系统中的含量符号说明有毒有害物质依据RoHS含量额外的产品标签内容1.产品的描述1.1使用者的适应症 (6)1.2禁忌症 (6)1.3警告和警惕 (6)1.4清洗和维护 (8)1.5RADIAnalyzer® Xpress的界面 (9)1.6使用者的绘图界面 (11)2.遵从法规要求2.1遵从的标准和导则 (18)2.2仪器外表上的标志 (20)3.RADIAnalyzer® Xpress的安装3.1安装设备 (22)3.2连接到电源 (23)3.3连接到实验室监测系统 (23)3.4连接到打印机RADIView TM..(选配) (23)3.5连接到RADIView TM(选配) (24)4.开始一个程序4.1打开系统 (26)4.2使RADIAnalyzer® Xpress和心脏介入检查室监测系统平衡 (26)4.3校准AO (27)4.4校准PressureWire® 传感器 (27)4.5输入病人的ID号 (28)4.6自动的开始顺序 (29)4.6.1平衡RADIAnalyzer® Xpress和心脏介入检查室监测系统 (29)4.6.2校准AO (29)4.6.3校准PressureWire® 传感器 (30)5.分次的流量测量5.1验证合适的压力信号 (32)5.2使Pa和Pd的压力均衡 (32)5.3使远端的位置传感器狭窄 (32)5.4诱导最大极限的充血 (32)5.5压力记录 (33)5.6停止记录并显示FFR (33)5.7使用指标器来确认FFR的价值 (33)5.8返回测量模式 (34)5.9断开PressureWire® 传感器 (34)6.测量传感器顶端的温度(选配)要求RADIAnalyzer® Xpress安装Thermo Option (34)7.测量冠状动脉血流储备,CFR(选配)要求RADIAnalyzer® Xpress安装Thermo Option (34)8.记录库8.1查看储存的记录 (36)8.2转移记录到RADView TM(选配) (36)8.3打印记录(选配) (36)8.4删除储存的记录 (36)9.仪器的设定9.1平均的压力计算结果 (38)9.2曲线图的扫描速度 (38)9.3曲线图的刻度 (39)9.4系统定时间 (39)9.5系统定日期 (39)9.6样本模式 (40)9.7Pd/Pa的曲线趋势 (40)9.8自动的开始顺序 (41)9.9监视器输出的敏感性 (41)10.维护10.1一年一次的检修 (43)10.2遥控装置电池 (43)10.3系统的备用电池 (43)10.4清洗 (43)10.5其他的维修/修理 (43)10.6一次性用品 (43)11.故障排除11.1屏幕信息 (44)12.规格12.1 技术规格 (45)担保声明:Radi Medical Systems AB拒绝所有的担保,不论操作者或者其他人明确的或者是含蓄的保证,包括但是不局限于对有销路的或者是适当的任何含蓄的担保。
手持频谱分析仪 FSH3 用户手册说明书
HandheldSpectrum Analyzer ¸FSHF i r s t Ed i t ion M a y 2004i¸FSH3 100 kHz to 3 GHz ¸FSH6 100 kHz to 6 GHz 800-404-ATEC (2832)E s t a b l i s h e d 19812Handheld Spectrum Analyzer ¸FSHThe ¸FSH is the ideal spectrum analyzer for rapid, high-precision, cost-effective signal investi-gations. It provides a large number of measure-ment functions and so can handle anything from the installation or maintenance of a mobile radio base station up to on-site fault location in RF cables as well as development and service – an extensive range of applications.Spectrum analysis anywhere, anytime– on earth and in spaceDue to its excellent characteristics, the ¸FSH3 is used on board the International Space Station (ISS) for distance-to-fault measurements on RF antenna cables.12Handheld Spectrum Analyzer ¸FSHHandheld Spectrum Analyzer ¸FSHGeneral instrument setupsDefault settingCurrent instrument settingRotary knobCursor keysColour display with 320×240 pixel, switchable to mono-chrome display for high-contrastdisplay when used in directsunlight in the fieldRS-232-C optical interfaceSimple menu-based operationvia softkeysMemory for up to 100 traces and setupsDirect printout of measure- ment resultsSelection of following functions: MarkerDelta marker Noise marker Frequency counter MultimarkerSelection of measurement functions:Spectrum analysisScalar network analysis Vector network analysis Receiver mode Channel power TDMA powerOccupied bandwidth DTF PowerTransducer factors Limit lines Display line4Handheld Spectrum Analyzer ¸FSH+¸FSH-Z1/-Z18+¸FSH-Z44+¸FSH-Z1/-Z18+¸FSH-Z2+¸FSH-B1+¸FSH-Z2+¸FSH-B1+¸FSH-Z44+¸FSH-Z1/-Z18+¸FSH-Z44+¸FSH-Z2+¸FSH-Z2+¸FSH-K3+¸FSH-K3+¸FSH-K3+¸FSH-K1+¸FSH-K1+¸FSH-K1A p p l i c a t i o n T D M A p o w e r m e a s u r e m e n t s C h a n n e l -p o w e r m e a s u r e m e n t s F i e l d -s t r e n g t h m e a s u r e m e n t s P o w e r m e a s u r e m e n t s u p t o 8 G H z /18 G H z D i r e c t i o n a l p o w e r m e a s u r e m e n tsu p t o 4 G H z M e a s u r e m e n t s o n c a b l e s (d i s t a n c e -t o -f a u l t )S c a l a r t r a n s m i s s i o n m e a s u r e m V e c t o r t r a n s m i s s i o n m e S c a l a r r e f l e c V e c t o Product1)¸FSH-K2 required¸FSH standard function Not availableThe ¸FSH is available as 3 GHz and 6 GHz models either with or without an internal tracking generator. When the tracking generator is included, the ¸FSH can be used for distance-to-fault (DTF) measurements, scalar and vector network analysis, and one-port cable loss measurement. Almost all models come standard with an adjustable preamplifier, making them suitable for measuring very small signals. Two power sensors are available as accessories – one for high-precision terminating power measurements up to 8 GHz or 18 GHz and one for directional power measurements up to 4 GHz. The following tables show possible configurations for various applications and an overview of available models.¸FSH – options and applicationsR e c e i v e r m o d e ¸FSH (models .03/.06) with preamplifier ¸FSH (model .13)with tracking generator ¸FSH (models .23/.26)with tracking generator and preamplifier¸FSH – modelsFrequency rangeTracking generatorOutput power of tracking generator PreamplifierResolution bandwidth¸FSH3 model .03100 kHz to 3 GHz –– 100 Hz to 1 MHz ¸FSH3 model .13100 kHz to 3 GHz –20 dBm– 1 kHz to 1 MHz ¸FSH3 model .23100 kHz to 3 GHz –20 dBm/0 dBm selectable 100 Hz to 1 MHz ¸FSH6 model .06100 kHz to 6 GHz ––100 Hz to 1 MHz ¸FSH6 model .26100 kHz to 6 GHz–10 dBm (f < 3 GHz)–20 dBm (f > 3 GHz)100 Hz to 1 MHzHandheld Spectrum Analyzer ¸FSH8Runs under Windows 98/ME/NT/2000/XPRapid and simple transfer of measurement data from the ¸FSH to a PC and vice versa Data export in ASCII or MS Excel formatPrintout of all relevant data via Windows(screenshot of the ¸FSH display for documentation) Graphics data stored in standard formats (.bmp, .pcx, .png, .wmf)Permanent and continuous transfer of sweeps to the PC; facilities for subsequent analysis (markers, zoom, etc)Storage space for traces and measurement data as well as forcomparisons of current and previous measurements (availablespace is limited only by the size of the hard diskof the controlling PC)Automatic storage of measurement results at selectable intervals Generation of cable data with a built-in cable editor; downloading to the ¸FSH for distance-to-fault mea-surements (¸FSH-B1) Editor for the generation of limit lines, transducerfactors and correction factors for external attenuators or amplifiers Generation of channel lists and uploading to the ¸FSH for the receiver mode (¸FSH-K3)Macro function for Word for fast and easy documentation of measurement results Connection between PC and ¸FSH via interference-free, RS-232-C optical interfaceFeatures:The powerful software package for documenting your measurements is supplied with every ¸FSH.Control Software ¸FSH View¸FSH3 ¸FSH6 FrequencyFrequency range100 kHz to 3 GHz100 kHz to 6 GHz Reference frequencyAging 1 ppm/yearTemperature drift0 °C to 30 °C30 °C to 50 °C 2 ppmin addition 2 ppm/10 °CFrequency counterResolution 1 HzCounter accuracy S/N > 25 dB± (frequency × reference frequency errror) Frequency span 0 Hz, 10 kHz to 3 GHz0 Hz, 10 kHz to 6 GHz Spectral puritySSB phase noise f = 500 MHz, 20 °C to 30 °C30 kHz from carrier<85 dBc (1 Hz)100 kHz from carrier<100 dBc (1 Hz)1 MHz from carrier<120 dBc (1 Hz)Sweep time span = 0 Hz 1 ms to 100 sspan > 0 Hz20 ms to 1000 s, min. 20 ms/600 MHz BandwidthsResolution bandwidths (–3 dB)1145.5850.131, 3, 10, 30, 100, 200, 300 kHz, 1 MHz1145.5850.03/.23,1145.5850.06/.26in addition 100 Hz, 300 HzTolerance≤300 kHz±5 %, nominal1 MHz±10 %, nominalResolution bandwidths (–6 dB)with option ¸FSH-K3installedin addition 200 Hz, 9 kHz, 120 kHz, 1 MHzVideo bandwidths10 Hz to 1 MHz in 1, 3 steps1) 80 V valid as of serial number 100900 (model 1145.5850.03) or 101600 (model 1145.5850.13); models 1145.5850.23, 1145.5850.06 and 1145.5850.26 all serial numbers.2)As of serial number 101362.¸FSH3¸FSH6AmplitudeDisplay rangeaverage noise level displayed to +20 dBm Maximum permissible DC voltage at RF input50 V/80 V 1)Maximum power20 dBm, 30 dBm (1 W) for max. 3 minutesIntermodulation-free dynamic rangethird-order IM products,2 × –20 dBm, reference level = –10 dBmtyp. 66 dB (typ. +13 dBm third-order intercept, IP3)Displayed average noise level 10 MHz to 3 GHz 3 GHz to 5 GHz 5 GHz to 6 GHz resolution bandwidth 1 kHz, video bandwidth 10 Hz, reference level ≤–30 dBm<–105 dBm, typ. –114 dBm ––<–105 dBm, typ. –112 dBm <–103 dBm, typ. –108 dBm <–96 dBm, typ. –102 dBm With preamplifier 10 MHz to 2.5 GHz 2.5 GHz to 3 GHz 3 GHz to 5 GHz 5 GHz to 6 GHz only models 1145.5850.032), 1145.5850.23, 1145.5850.06 and 1145.5850.26<–120 dBm, typ. –125 dBm <–115 dBm, typ. –120 dBm ––<–120 dBm, typ. –125 dBm <–115 dBm, typ. –120 dBm <–115 dBm, typ. –120 dBm <–105 dBm, typ. –110 dBmInherent spuriousreference level≤–20 dBm, f > 30 MHz, RBW ≤ 100 kHz <–80 dBm <–80 dBm Input related spuriousUp to 3 GHz 3 GHz to 6 GHzSignal frequency minus –2.0156 GHz for signal frequencies 2 GHz to 3.2 GHz mixer level –40 dBm,carrier offset >1 MHz<–70 dBc (nominal)–typ. <–55 dBc <–70 dBc (nominal)<–64 dBc (nominal)typ. <–55 dBc 2nd harmonic mixer level –40 dBmtyp. <–60 dBctyp. <–60 dBcLevel display Reference level –80 dBm to +20 dBm in steps of 1 dB Display range 100 dB, 50 dB, 20 dB, 10 dB, linear Display unitsLogarithmic Linear dBm, dBµV, dBmVwith transducer also dBµV/m and dBµA/m µV, mV, V, nW, µW, mW, Wwith transducer also V/m, mV/m and µV/m Traces 1 trace and 1 memory traceDetectorsauto peak, maximum peak, minimum peak, sample, RMSwith option ¸FSH-K3 installedin addition average and quasi-peak Level measurement errorfrequency >1 MHz,at reference level down to –50 dB, 20 °C to 30 °C<1.5 dB, typ. 0.5 dB¸FSH3¸FSH6 MarkersNumber of markers or delta markers max. 6Marker functions peak, next peak, minimum,center = marker frequency,reference level = marker level, all markers to peak Marker displays normal (level), noise marker, frequency counter (count)Trigger free-running, video, externalAudio demodulation AM (video voltage without AGC) and FM InputsRF input N femaleInput impedance50 ΩVSWR10 MHz to 3 GHz10 MHz to 6 GHz typ. 1.5––typ. 1.5Trigger/external reference input BNC female, selectable Trigger voltage TTLReference frequency10 MHzRequired level from 50 Ω10 dBm OutputsAF output 3.5 mm mini jackOutput impedance Open-circuit voltage 100 Ωadjustable up to 1.5 VTracking generator only models 145.5850.13,1145.5850.23 and1145.5850.26Frequency range 5 MHz to 3 GHz 5 MHz to 6 GHzOutput level model 1145.5850.13model 1145.5850.23model 1145.5850.26f < 3 GHzf > 3 GHz –20 dBm (nominal)0 dBm/–20 dBm, selectable–10 dBm (nominal)–20 dBm (nominal)Output impedance50 Ω, nominalInterfacesRS-232-C optical interfaceBaud rate1200, 2400, 9600, 19200, 38400, 57600, 115200 baud Power sensor7-contact female connector (type Binder 712)¸FSH3¸FSH6 AccessoriesPower Sensors ¸FSH-Z1 and ¸FSH-Z18Frequency range¸FSH-Z110 MHz to 8 GHz¸FSH-Z1810 MHz to 18 GHzVSWR10 MHz to 30 MHz 30 MHz to 2.4 GHz 2.4 GHz to 8 GHz 8 GHz to 18 GHz <1.15 <1.13 <1.20 <1.25Maximum input power average powerpeak power(<10 µs, 1 % duty cycle)400 mW (+26 dBm) 1 W (+30 dBm)Measurement range200 pW to 200 mW (–67 dBm to +23 dBm) Signal weighting average powerEffect of harmonics Effect of modulation <0.5 % (0.02 dB) at harmonic ratio of 20 dBc<1.5 % (0.07 dB) for continuous digital modulationAbsolute measurement uncertainty sine signals, no zero offset10 MHz to 8 GHz 8 GHz to 18 GHz 15 °C to 35 °C0 °C to 50 °C15 °C to 35 °C0 °C to 50 °C<2.5 % (0.11 dB)<4.5 % (0.19 dB)<3.5 % (0.15 dB)<5.2 % (0.22 dB)Zero offset after zeroing<150 pWDimensions (W × H × D)48 mm × 31 mm × 170 mm, connecting cable 1.5 m Weight<0.3 kgDirectional Power Sensor ¸FSH-Z44Frequency range200 MHz to 4 GHzPower measurement range30 mW to 120 W (300 W with unmodulated envelope) VSWR referenced to 50 Ω200 MHz to 3 GHz 3 GHz to 4 GHz <1.07 <1.12Power-handling capacity depending on temperatureand matching(see diagram below)120 W to 1000 W Insertion loss200 MHz to 1.5 GHz 1.5 GHz to 4 GHz <0.06 dB <0.09 dBDirectivity200 MHz to 3 GHz 3 GHz to 4 GHz >30 dB >26 dBSignal weighting average powerMeasurement uncertainty200 MHz to 300 MHz300 MHz to 4 GHz sine signals,18 °C to 28 °C,no zero offset4 % of measured value (0.17 dB)3.2 % of measured value (0.14 dB)¸FSH3¸FSH6Zero offsetafter zeroing ± 4 mWRange of typical measurement error with modulationFM, PM, FSK, GMSK AM (80 %) cdmaOne, DAB3GPP WCDMA, cdma2000 DVB-T π/4-DQPSKif standard is selected on ¸FSH0 % of measured value (0 dB)±3 % of measured value (±0.13 dB)±1 % of measured value (±0.04 dB)±2 % of measured value (±0.09 dB)±2 % of measured value (±0.09 dB)±2 % of measured value (±0.09 dB Temperature coefficient 200 MHz to 300 MHz 300 MHz to 4 GHz0.40 %/K (0.017 dB/K)0.25 %/K (0.011 dB/K)Matching measurement range Return loss200 MHz to 3 GHz 3 GHz to 4 GHz VSWR 200 MHz to 3 GHz 3 GHz to 4 GHz 0 dB to 23 dB 0 dB to 20 dB >1.15>1.22Minimum forward powerspecs met from 0.2 W0.03 WDimensions (W × H × D)120 mm × 95 mm × 39 mm, connecting cable 1.5 m Weight 0.65 kg���������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������Power-handling capacity Limits of measurement error for matching measurements¸FSH3¸FSH6 VSWR Bridge and Power Divider ¸FSH-Z2Frequency range10 MHz to 3 GHzImpedance50 ΩVSWR bridgeDirectivity10 MHz to 1 GHz 1 GHz to 3 GHz typ. 30 dB typ. 25 dBDirectivity, corrected10 MHz to 3 GHz option ¸FSH-K2typ. 43 dBReturn loss at test port typ. 20 dBReturn loss, corrected option ¸FSH-K2 typ. 35 dBInsertion loss typ. 9 dBPower dividerReturn loss at test port typ. 20 dBConnectorsGenerator input/RF output N maleTest port N femaleControl interface7-contact connector (type Binder) Calibration standardsShort/open N male50 Ω load N maleImpedance50 ΩReturn loss up to 3 GHz>43 dBPower-handling capacity 1 WGeneral dataPower consumption500 mW (nominal) Dimensions (W × H × D)169 mm × 116 mm × 30 mm Weight485 gDistance-to-Fault Measurement ¸FSH-B1 (only model 1145.5850.13, 1145.5850.23 or 1145.5850.26) Display301 pixelsMaximum resolution, distance to fault maximum zoom cable length/1023 pixels Display rangeReturn lossVSWRwith option ¸FSH-K210, 5, 2, 1 dB/div, linear1 to2 and 1 to 6in addition 1 to 1.2 and 1 to 1.5Cable length depending on cable loss 3 m to max. 1000 mMaximum permissible spurious signal1st mixer 1 dB compression point typ. +10 dBmIF overload at reference level typ. +8 dB¸FSH3¸FSH6 Transmission measurements (only with ¸FSH3 models 1145.5850.13, 1145.5850.23 and ¸FSH6 model 1145.5850.26)Frequency range 5 MHz to 3 GHz 5 MHz to 6 GHzDynamic range10 MHz to 2.2 GHz2.2 GHz to 3 GHz3 GHz to 5 GHz5 GHz to6 GHz scalar modevector mode,option ¸FSH-K2scalar modevector mode,option R&S FSH-K2scalar modevector mode,option ¸FSH-K2scalar modevector mode,option ¸FSH-K2typ. 60 dBtyp. 80 dBtyp. 50 dBtyp. 65 dB––––typ. 80 dBtyp. 90 dBtyp. 70 dBtyp. 85 dBtyp. 40 dBtyp. 55 dBtyp. 35 dBtyp. 50 dBReflection measurements(only with ¸FSH3 model 1145.5850.13 or 1145.5850.23, ¸FSH6 model 1145.5850.26 and ¸FSH-Z2)Frequency range10 MHz to 3 GHz10 MHz to 3 GHz Display range of return loss10, 20, 50, 100 dB, selectableVSWR display range 1 to 2 and 1 to 6, selectable,with option ¸FSH-K2 also 1 to 1.2 and 1 to 1.5 Measurement uncertainty see diagramsMeasurement uncertainty with vector measurements,(option ¸FSH-K2)Measurement uncertainty with scalar measurementsGeneral dataDisplay14 cm (5.7“) LC colour display Resolution320 × 240 pixelsMemory Settings and traces CMOS RAM 100Environmental conditions TemperatureOperating temperature range¸FSH powered from internal battery ¸FSH powered from AC power supply 0 °C to 50 °C 0 °C to 40 °CStorage temperature range–20 °C to +60 °CBattery charging mode0 °C to 40 °CClimatic conditionsRelative humidity95 % at 40 °C (EN 60068)IP class of protection51Mechanical resistanceVibration, sinusoidal complies with EN 60068-2-1, EN 61010-15 Hz to 55 Hz: max 2 g, 55 Hz to 150 Hz: 0.5 g constant,12 minutes per axisVibration, random complies with EN 60068-2-64, 10 Hz to 500 Hz, 1.9 g,30 minutes per axisShock complies with EN 60068-2-27, 40 g shock spectrum RFI suppression complies with EMC directive of EU (89/336/EEC)and German EMC legislationImmunity to radiated interferenceLevel display at 10 V/m (reference level ≤–10 dBm) Input frequencyIFOther frequencies 10 V/m<–75 dBm (nominal) <–85 dBm (nominal) < displayed noise levelPower supplyAC supply plug-in AC power supply (¸FSH-Z33)100 V AC to 240 V AC, 50 Hz to 60 Hz, 400 mA External DC voltage15 V to 20 VInternal battery NiMH battery, type Fluke BP190 (¸FSH-Z32)Battery voltage 6 V to 9 VOperating time with fully-charged battery 4 h with tracking generator off,3 h with tracking generator onLifetime300 to 500 charging cyclesPower consumption typ. 7 WSafety complies with EN 61010-1, UL 3111-1,CSA C22.2 No. 1010-1Test mark VDE, GS, CSA, CSA-NRTLDimensions (W × H × D)170 mm × 120 mm × 270 mmWeight 2.5 kgHeadphonesRS-232-C cableAC power supplyAC supply connector (country-specific)VSWR Bridge and Power Divider R&S FSH-Z2Power Sensor R&S FSH-Z1Power sensorconnector on R&S FSH3Ordering informationDesignationType Order No.Handheld Spectrum Analyzer, 100 kHz to 3 GHz, with preamplifier¸FSH31145.5850.03Handheld Spectrum Analyzer, 100 kHz to 3 GHz, with tracking generator¸FSH31145.5850.13Handheld Spectrum Analyzer, 100 kHz to 3 GHz, with tracking generator and preamplifier ¸FSH31145.5850.23Handheld Spectrum Analyzer, 100 kHz to 6 GHz, with preamplifier¸FSH61145.5850.06Handheld Spectrum Analyzer, 100 kHz to 6 GHz, with tracking generator and preamplifier¸FSH61145.5850.26Accessories suppliedExternal power supply, battery pack (built-in), RS-232-C optical cable, headphones, Quick Start manual, CD-ROM with Control Software ¸FSH View and documentationOptionsDesignationType Order No.Distance-to-Fault Measurement(includes 1 m cable, ¸FSH-Z2 required)¸FSH-B11145.5750.02Remote Control via RS-232-C¸FSH-K11157.3458.02Vector Transmission and Reflection Measurements ¸FSH-K21157.3387.02Receiver Mode¸FSH-K31157.3429.02Optional accessoriesDesignationType Order No.Power Sensor, 10 MHz to 8 GHz¸FSH-Z11155.4505.02VSWR Bridge and Power Divider, 10 MHz to 3 GHz (open, short, 50 Ω load)¸FSH-Z21145.5767.02Power Sensor, 10 MHz to 18 GHz¸FSH-Z181165.1909.02Directional Power Sensor, 200 MHz to 4 GHz ¸FSH-Z441165.2305.02Matching Pad 50/75 Ω, 0 Hz to 2700 MHz¸RAZ 0358.5714.02Spare RF Cable (1 m), connectors N male/N female for ¸FSH-B1¸FSH-Z201145.5867.0212 V Car Adapter¸FSH-Z211300.7579.02Serial/Parallel Converter ¸FSH-Z221145.5880.02Carrying Bag¸FSH-Z251145.5896.02Transit case¸FSH-Z261300.7627.00Combined Short/Open and 50 Ω Load for VSWR and DTF calibration ¸FSH-Z291300.7504.02Spare Short/Open Calibration Standard for ¸FSH-Z2 for VSWR calibration ¸FSH-Z301145.5773.02Spare 50 Ω Load Standard for ¸FSH-Z2 for VSWR and DTF calibration ¸FSH-Z311145.5780.02Spare Battery Pack ¸FSH-Z321145.5796.02Spare AC Power Supply ¸FSH-Z331145.5809.02Spare RS-232-C Optical Cable¸FSH-Z341145.5815.02Spare CD-ROM with Control Software ¸FSH View and documentation¸FSH-Z351145.5821.02�����������������������������������������������������������������������More information at Rohde &Schwarz direct: Tel. (+49 2203) 807-800Fax (+49 2203) 807-66E-mail:************************。
OMRON D3SH 最小检测开关说明书
㧰3S HThe smallest detectionswitch in the world. Ideal for miniature mobile devices(OMRON's data as of September 2007)●Ultra small size and ultra low profile contributing to down-sizing of sets devices. (3.0 × 3.4 × 0.9 mm (W × D × H))●A unique mechanism enables high contact reliability and high precision operation.●Horizontal 2-way detection and long stroke for easy installation are available.●Meet a variety of applications by contact and lever variationsRoHS CompliantContact FormList of Models●Standard Lever Models●Long Lever ModelsContact SpecificationsRatingsNote.The ratings values apply under the following test conditions:(1) Ambient temperature: 20±2°C (2) Ambient humidity: 65±5%(3) Operating frequency: 20 operations/min●SPST-NO●SPST-NCContact SpecificationsSlideMinimum applicable load15 μA at 3 VDCRated voltageResistive load5 VDC1 mAD3SHSurface Mount Switch㧰3S HCharacteristicsNote: The data given above are initial values.*1.The given values apply for Total Travel Position. Close or open circuit of the contact is 1ms max.*2.For testing conditions, consult your OMRON sales representative.Dimensions(Unit: mm) and Operating CharacteristicsThe @ is replaced with the code for the contact form that you need. See the "List of Models" for available combinations of models.Note 1.Unless otherwise specified, a tolerance of Note 2.The operating characteristics are for operation in the A direction ($) and B direction (", !) has the same operation characteristic values as of the A direction.Permissible operating speed 1 mm to 300 mm/sPermissible operating frequency Mechanical 60 operations/min Electrical 60 operations/minInsulation resistance100 M Ω min. (at 100 VDC with insulation tester)Contact resistance (initial value) 3Ω max.Dielectric strengthBetween terminals of the same polarity 100 VAC (50/60 Hz for 1 min) Vibration resistance *1 Malfunction 10 to 55 Hz, 1.5 mm double amplitudeShock resistanceDurability 1000 m/s 2 {approx. 100G} max. Malfunction *1 300 m/s 2 {approx. 30G} max. Durability *2Mechanical 150,000 operations min. (20 operations/min) Electrical 100,000 operations min. (20 operations/min)Ambient operating temperature -25 to +85°C (at ambient humidity 60% max.) (with no icing or condensation)Ambient operating humidity 85% max. (for +5 to +35°C)WeightApprox. 0.02 gOperating Characteristics ModelD3SH-@@R D3SH-@@L Operating Force OF Max. 0.3 N {31 gf}Free PositionOperating Position Total Travel PositionFP OP TTP5.4±0.2 mm 5.0±0.2 mm 3.8±0.15 mmD3SHSurface Mount Switch㧰3S HNote 1.Unless otherwise specified, a tolerance of Note 2.The operating characteristics are for operation in the A direction ($) and B direction (", !) has the same operation characteristic values as of the A direction.Note 2.The operating characteristics are for operation in the A direction ($) and B direction (", !) has the same operation characteristic values as of the A direction.Operating Characteristics ModelD3SH-@@R1 D3SH-@@L1 Operating Force OF Max. 0.24 N {24 gf}Free PositionOperating Position Total Travel PositionFP OP TTP5.9±0.3 mm 5.4±0.3 mm 3.8±0.2 mm●Right operating - with Boss D3SH-@1R●Left operating - with Boss D3SH-@1L●Right operating - without BossD3SHSurface Mount Switch㧰3S HNote 1.Unless otherwise specified, a tolerance of Note 2.The operating characteristics are for operation in the A direction ($) and B direction (", !) has the same operation characteristic values as of the A direction.●Right operating - with Boss D3SH-@1R1●Left operating - with Boss D3SH-@1L1D3SHSurface Mount Switch㧰3S HPrecautions★Please refer to "Common Precautions" for correct use.●Electrical Ratings•Confirm the contact load in order to select an appropriate switch rating.•Do not apply an excessive electrical load to the contacts,otherwise the contacts may weld, resulting in a short circuit or burning.●Terminal Connection•Do not use flow soldering or hand soldering to solder terminals.•Conduct reflow soldering within the range shown in the terminal temperature profile below.Some reflow soldering devices have extremely high peak values. Do a test in advance to confirm proper soldering conditions.•Do not conduct reflow soldering more than twice. Also provide a time interval of at least five minutes between the first and second reflow soldering processes to allow the Switch to return to room temperature.Heating the Switch continuously (without an interval) may cause the edges of the Switch to melt and degrade the characteristics.•When printing for a cream solder process, a 0.13 mm screen thickness is recommended.•Be sure to provide local ventilation.●Printed Circuit BoardsSpecial attention must be paid to the handling of printed circuit boards after a Switch has been mounted onto them. Airborne PCB particles may penetrate the interior of the Switch when printed circuit boards are separated by cutting. Also, do not stack printed circuit boards that have Switches mounted on them.●Product Specification Details•This document provides only a partial list of specifications. It is recommended that you request complete drawings and specifications prior to purchasing or using the product.●Mounting•The cover has the same electric potential as the COM terminal. Do not short-circuit the cover with a NO or NCterminal when mounting the cover.•Be careful of the following points. Incorrect handling may lead to insufficient actuator return, Switch damage, or reduced durability.-Set the operating body in line with the direction of the actuator movement, and make sure that the operating body is completely separate from the actuator when the Switch is in the free position (FP). When the actuator is operated from the crosswise direction of the Switch, make sure that the corner of the operating body has a minimum radius of R1.-(the difference between the operating position and the total travel position).-Do not subject the Switch to operations that involve strong impact.-Do not use the Switch as a stopper.-Do not apply excessive loads to the cover or operate the actuator from a direction other than a specified operating direction.-Do not use an adhesive to secure the Switch.•A lubricant is used in the Switch. Some of the lubricant may seep out because the Switch does not have an airtight construction. Consider this possibility with respect to the usage conditions when designing or using the Switch.●Application EnvironmentDo not use the Switch in locations that are subject to toxic gas, silicon, excessive dust, excessive dirt, high temperatures, high humidity, sudden temperature changes, water splashes, or oil splashes.Otherwise, damage resulting by faulty contact of the Switch contacts, corrosion, or other causes, or other functional faults may occur.●Insulation and WiringBe sure that the installation conditions provide a sufficient insulation distance between Switch terminals and other metal parts, lands, etc.●CleaningThe Switch does not have an airtight construction, and it must not be cleaned with cleaning fluids. Malfunctions may occur if the cleaning fluid penetrates the interior of the Switch together with flux or foreign matter from the surface of the PCB.●Confirmation with Actual EquipmentBe sure to confirm the quality of the product under the load and environmental conditions that will be used during actual applications.CautionCorrect UseCoverD3SH Surface Mount Switch 㧰3SH。
施耐德SH3 系列伺服电机产品手册_V202_ZH
dd.mm.yyyy
14
I0 0.00 Arms Nmax 0000 rpm nN 0000 rpm IPxx(xx)
15
UN 000 Vrms
Ubr rmo PTC
Pbr 0 W
Th-CI F DT-F2 E208613
Mbr 0 Nm
17
18
Made in Germany
2
伺服电机
0198441113991, V2.02, 10.2012
SH3
目录
重要说明 目录 关于本手册 1 序言 1.1 电机系列 1.2 可选件和配件 1.3 铭牌 1.4 型号代码 2 开始之前 - 安全信息 2.1 操作人员资质 2.2 指定用途 2.3 危险等级 2.4 基本信息 2.5 标准和术语 3 技术参数 3.1 常规属性 3.2 特定电机数据
9.2 术语和缩写
4
SH3
53
53
55
57 59
60 60 63 69
71
73
73
73
75
75
75
76 76 77 78 79
80
81
81
81
81
83
83
85
85 85 85 85 85 86 86 86 86 86
87
伺服电机
0198441113991, V2.02, 10.2012
SH3
10 图表目录 11 关键字索引
类型 00 = 标准
1) 仅在特定电机型号时可用,参见"3.2 特定电机数据"一章。 2) 本手册中仅对此处列明的规格做出说明。 3) 安装位置为 IM V3(立式驱动轴,轴末端朝上)时只能达到防护等级 IP50。 4) 硬件版本 ≥RS03: 可连接压缩空气,以达到 IP67。参见章节 "4.4.1 压缩空气连接"。 5) 可连接压缩空气,以达到 IP67。参见章节 "4.4.1 压缩空气连接"。
罗德与施瓦茨公司 频谱分析仪 R S FS300 FS315 说明书
频谱分析仪R &S ®FS300/FS3159kHz 至 3GHz二○○六年三月第四版精灵仪器系列R &S 公司新产品系列高质量的测量特性分辨率带宽: 200Hz至20MHz (¸FS315)1 Hz分辨率的频率计数器最大输入电平: 33 dBm符合人类工程学的用户接口经由USB接口的远端控制AM/FM音频解调输出(¸ FS315)简要数据表¸FS3159kHz 到 3GHz200Hz 到 20MHz10Hz 到 20MHz典型值-115 dBm(300Hz)-70dBc, -36dBm输入电平-90dBc(1Hz)1.5dB,典型值0.7dB最大/最小峰值,取样,平均,RMSTOI,TDMA, 频率计,噪声标记,占用带宽(OBW), 回波损耗,传输,信道功率9kHz 到 3GHzAM/FM有菜单区显示用以设置参数和功能的各个菜单符合人类工程学的用户接口操作是由菜单指导的,所以,即使没有经过培训的用户也会迅速地获得正确的结果。
清晰的结构可以使菜单内的导向得到简化。
明亮的TFT 彩色显示器使得即使在异常的角度或当光线不佳时也可以查看各显示迹线。
软键区显示随着所选定的菜单而变化的不同的仪器功能旋转旋钮用以逐渐地改变仪器的各参数数字小键盘用以输入各数值参数箭头用以在菜单内的导向连接器跟踪源输出 (¸FS315)按钮用以确认所输入的数值系统键用以调用系统和维修功能应用范围¸FS300/315是一种通用的频谱分析仪,适用于实验室、维修服务和生产方面的各种综合测量。
PC机软件在通过一个PC机对¸ FS300/FS315进行远端控制的方面,可以提供一种功能强大的软件选件。
该软件可以增强¸ FS300/ FS315的各功能,并支持在PC机上生成各种测试报告。
RF 频谱(电平和频率)的测量辐射性干扰 (EMC) 的测量标量网络分析(仅¸ FS315)时域测量经由USB接口的无线电监测的远端控制特性■与Windows 2000/XP相兼容■PC机可以经由方便的USB接口连接到¸ FS300/ FS315■各测量在¸ FS300/FS315与PC机之间的快速而简捷的传送■持久的扫描和正在进行的扫描向PC机传送,具有评价能力(标志、图像缩放等)■不受限制的存储器容量,用于存储各踪迹线和测量信息(当前测量与先前测量的比较)■扩充的功能范围 (各容限度线 (limit lines),记录文件(log file))■以文本格式输出迹线示值 (900点),具有适合输入给微软Excel的优点■以JPEG格式输出所显示的数据 (屏幕拍摄)■各测量结果输出给标准USB接口的打印机准备就绪,适应未来—新型的仪器系列¸ FS300/FS315是用于开发、维修和生产的新型分析仪和发生器家族中的一员。
S3火花直读光谱仪说明书
传承自1942年的意大利精密仪器公司S3火花直读光谱仪LINEE STAMPAGGIO LAMIERA SISTEMI·DI RADDRIZZATURA·STRUMENTI PROVE MATERIALI1.分析范围 (03)2.优势说明 (05)3.公司介绍 (13)4.客户名单 (21)5.技术参数 (29)6.仪器安装要求 (34)7.售后服务条款 (35)1.分析范围用户提供标样,厂家现场增加测量上限分析范围用户提供标样,厂家现场增加测量上限分析范围用户提供标样,厂家现场增加测量上限1、圆柱体测断面,截取一小段,放入线材适配器(下图),固定好位置,放在样品台上检测;一套7个2、比较细的线材,或管材,放入管材适配器(下图),即可检测;3、对于不规则样品,可使用减径环(下图);氮化硼减径环内径尺寸为:3、5、8mm;2.优势说明1.同级别直读光谱仪中最稳定的精度为了获得最佳的检测精度,GNR研发团队通过几十年的技术积累,采用了多种行业最领先的技术来达到这一目的。
a.采用单块标样的智能校准法+波长实时校准由于光学器件会受到空气污染,谱线的光强度(图1中谱线的高度)会变化,而谱线高度代表着元素含量,因此谱线高度的忽高忽低会影响测样结果的稳定性。
一般直读光谱仪需要用5-9块标样来做全校准,而GNR的智能校准算法可以精确计算每个待测元素的每条谱线的高度变化,做到最精密的校准。
GNR通过几十年累计的测试数据来拟合元素之间的关联,从而用一块标样的校准来达到多块标样校准的效果。
由于温度的变化及仪器环境的震动等原因,谱线会发生水平方向的漂移,这同样会导致含量的忽高忽低,因而影响测样结果的稳定性。
波长实时校准可以在每次激发预燃烧时精确计算每个待测元素的每条谱线的最新像素点,确保准确检测元素的谱线位置,从而达到最稳定的测样精度。
图1.智能校准费+波长实时校准效果图(双击图片显示动态图)b.分辨率最高的COMS检测器CMOS与CCD对比CMOS CCD封装外形如上图,24P和CMOS非常类似,22P像素40963648单个像素尺寸7*200um8*200um单个器件感光长度28.672mm29.184mm感光灵敏度650V/(lx.s)160V/(lx.s)暗电流电压(TYP)0.1mV2mVGNR采用了CMOS作为最新款直读光谱仪的检测器,相比较之前的CCD,在元器件性能上有如下的性能提升:首先这两款元器件(CMOS和CCD)采用了想类似的芯片封装,在结构上除了CMOS 是24针脚,CCD是22针脚以外,其他几乎完全一致。
罗德施瓦茨FSH3说明书
8. NiMH 电池不可放置于高温下或火中。 电池 应远离于儿童放置。 若电池误换, 则会引起爆炸。替换电池应为 R&S 系列 (参见备用零件列表). NiMH 电池 是属于 环保 类型的电池 并 能够 回收 再利用 。 故 应 将 投入 相应的 回收箱内 。要避免 造成短路 。
6. 在操作过程中,应遵守地方与国家的安全规章制度。 在操作仪器和开机前, 仪器应与电源系统处于断电状态。 各种部件的调整,替代, 保养或维修应只由 R&S 授权的技术人员来操作。 只有原配部件方可用来替换安全相关的部件 (如电源开关, 变压器, 保险丝). 安全检测须在每次更换安全 相关部件后进行。 (视觉监测, 导电检测, 绝缘测量, 漏电测试, 功能检测).
2. 在测量电压为 Vrms > 30 V 的电路时, 须使用正确的方法避免危险 (例如,使用正确的设备,保险丝, 电流的限定和绝缘 功能).
3. 在未安装内置保险丝, 断路器或其他类似的保护装置仪器中, 备用电路板须有保险装置。 4. 在开机前,确保仪器调制的额定电压要符合 AC 供电网络的额定电压。
目录
1 安全说明................................................................................................................................ 2 2 质量认证........................................................................................................................
罗德施瓦茨手持频谱仪使用说明书
应用
产品 ¸FSH (型号. 03/.06) 带有前放
■
率 A功 TDM
测量
测量 功率 测量 道 信 场强
量 2) 输测 量 Hz) G 传 测 4 ) / z z 功率 矢量 GH 反射 8GH 量/ z/1 至1 码域 ) 矢量 控制 测 ( GH / F 行 8 T 至 传输 比 测量 (D 测量 远程 口 缆 站进 模式 量( 标量 噪声 功率 测量 反射 通过 32-C接 口线 列表 PP基 机 测 G 波 向 缆 量 道 3 2 载 定 线 标 信 对 接收 RS- 一端 测量 功率 损耗 测量
¸FSH18
10 MHz 至 18 GHz
–
–
100 Hz 至 1 MHz
4
手持式频谱分析仪¸FSH
TDMA功率测量
基本上,当使用 TDMA 功能时, ¸FSH 可以完成 TDMA (时分 多址接入)一个时隙内时域功率测量。所有符合 GSM/EDGE 标 准的设置在¸FSH内做了预先设置,用户使用非常方便。而 且,用¸FSH 显示软件可加载多达5个仪器配置。
手持式频谱分析仪¸FSH
7
用驻波桥测量标量传输和反射 (选件¸FSH-Z2/Z3)
有内置跟踪源的 ¸FSH 可以简单操作迅速地测量电缆、滤 波器、放大器等器件的传输特性。如果安装了 VSWR 桥 ¸ FSH-Z2/Z3(10 MHz到3 GHz/6 GHz)),举例而言¸FSH还可以测量 天线的匹配(反射损耗或者电压驻波比)。驻波桥可以直接 接到仪表的RF输入端和跟踪源输出端,省却了例如外部电缆等 多余配件。创新设计的¸FSH-Z3驻波桥具有集成的射频旁路 开关,在驻波桥连接的情况下也允许用户进行频谱和传输的测 量.例如放大器一类的有源器件可由两个集成的偏置接口通过 射频电缆供电。
罗氏中文说明书:甲状腺球蛋白检测试剂盒(电化学发光法)说明书
【产品名称】通用名称:甲状腺球蛋白检测试剂盒(电化学发光法)英文名称:Tg II【包装规格】100测试/盒【预期用途】主要用途用于体外定量测定人血清和血浆的甲状腺球蛋白含量。
Tg的测定能辅助监控甲状腺切除术后的情况。
Elecsys和cobas e 免疫分析仪的工作原理是电化学发光免疫分析“ECLIA”。
临床应用甲状腺球蛋白是一种分子量接近660 kDa的糖蛋白。
4Tg由甲状腺细胞大量合成并释放到甲状腺滤泡腔内。
TSH、甲状腺内碘缺乏、促甲状腺激素免疫球蛋白均可刺激Tg的生成。
Tg对外周甲状腺激素T3和T4的合成起决定作用。
它含有约130种酪氨酸残基,其中一部分在TPO(甲状腺过氧化物酶)和碘化物存在时被碘化为单碘-和二碘酪氨酸(MIT和DIT)。
3随后也是在Tg和TPO的作用下,MIT和DIT偶联结合成T3和T4。
5甲状腺细胞合成Tg以及将Tg转送到滤泡的过程中,少量蛋白可进入血流。
因此无甲状腺疾病的健康个体中也能检出低浓度Tg。
Tg浓度升高在不同的甲状腺疾病中均有报道,桥本氏病、葛瑞夫兹病等。
Tg还有助于鉴别亚急性甲状腺炎和人为甲状腺毒症。
对于先天性甲状腺功能减退症Tg的检测可用于鉴别先天性甲状腺缺失和甲状腺发育不全或其它病理情况。
5,6,7Tg检测主要用于甲状腺全切或次全切术后病人的随访。
由于甲状腺是Tg的唯一已知来源,在甲状腺全切或次全切伴随放射性碘成功消融残留甲状腺组织后,血清Tg浓度将降至极低,甚至检测不到。
对于部分甲状腺切除的病人,检测到的Tg水平取决于手术后残留的甲状腺组织的多少。
若甲状腺全切术后仍可检出Tg则提示DTC残留或复发。
因此Tg明显升高常提示该疾病复发。
8,9,10,11,12,13采用高灵敏度Tg检测后,“甲状腺球蛋白阳性”病人数量增加,即使这些病人并未表现出疾病症状。
13不能认为这些病人没有疾病,应根据当前指南进行监测随访。
已有不同临界值报道用以鉴别仅需监测的病人和那些需要接受进一步诊断和治疗的复发病人。
FSH(促卵泡激素)检测作业指导书
《文件已阅声明表》《Procedure Circulation Form》文件名称(File Name): 卵泡刺激素(FSH)检测作业指导书《文件本次修改记录表》《Procedure Amendment Form》《文件信息表》《Procedure Information Form》卵泡刺激素检测作业指导书1.目的检测人血清或血浆样本中卵泡刺激素(FSH)的浓度,作临床辅助诊断用。
2.检测原理采用Chemiflex®的化学发光微粒子免疫检测(CMIA)技术,对人血清,血浆中卵泡刺激素进行定量测定。
第一步,将混合样本和抗-β卵泡刺激素包被顺磁性微粒。
样本中的卵泡刺激素与抗-β卵泡刺激素包被微粒相结合。
冲洗后进入第二步,添加抗-α卵泡刺激素抗体吖啶酯标记结合物。
然后向反应混合物中添加预激发液和激发液。
对产生的化学发光反应物进行测量,以相对光单位(RLUs)表示。
样品中的卵泡刺激素含量与ARCHITECT i光学系统检测到的RLUs值成正比。
3.样本的采集和贮存3.1 ARCHITECT卵泡刺激素项目可以使用人血清(包括采集于血清分离管中的血清)或采集于肝素钠、肝素锂或EDTA 钾抗凝管中的血浆。
3.2标本溶血超过+++以上的情况下退单。
3.3稳定性: 2-8℃可稳定7天3.4样本贮存: 2-8℃保存10天4.试剂和仪器4.1试剂成分:4.1.1检测试剂盒ARCHITECT促卵泡激素测定试剂盒(7K75)微粒子:1瓶或4瓶(6.6ml/27.0ml)抗-β卵泡刺激素(小鼠,单克隆)包被微粒,储存于MES缓冲液中(含鼠和山羊蛋白稳定剂)。
防腐剂:抗菌剂。
结合物:1瓶或4瓶(5.9ml/26.3ml)抗-α卵泡刺激素(小鼠,单克隆)吖啶酯标记结合物,储存于MES缓冲液中(含牛蛋白稳定剂)。
最低浓度:45ng/mL。
防腐剂:抗菌剂。
4.1.2项目专用稀释液 1瓶(100ML)ARCHITECT i多项目手工稀释液,含有磷酸盐缓冲盐溶液。
热病 Sanford 指南应用程序用户指南.pdf_1700054499.4445264说明书
SANFORD GUIDE COLLECTION聯絡窗口:陳永祥聯繫電話:(02)2658-2223#3431234目錄CONTENTS關於熱病開始安裝上手使用注意事項P art01關於熱病ABOUT SANFORD GUIDE COLLECTION關於熱病Sanford Guide被廣泛運用於院內的內科醫師、藥劑師以及臨床醫師等的熱病,現提供更方便查閱的App版!•以紙本內容為基礎,提供更便利的瀏覽搜尋介面。
•每月進行更新,以提供最新的醫藥資訊•即使在沒有網路的情況下,醫護人員還是可以使用APP進行資料檢索與瀏覽。
收錄內容包括有各系統器官感染疾病的常見病原體、傳播途徑、診斷要點、首選和備選治療方案、藥物不良反應和應用注意事項,以及預防用藥等,並輔以有關文獻來體現實證醫學的權威性;涉及的病原體有細菌、真菌、寄生蟲和病毒等。
Antimicrobial Therapy 整合Sanford Guide 的Antimicrobial Therapy 、HIV/AIDS Therapy 和Hepatitis Therapy 的所有內容HIV/AIDS Therapy Hepatitis Therapy關於Sanford Guide Collection APP與紙本截然不同的使用者體驗More Information無縫整合收錄內容,並可對外連接至PubMed等資源Organized by Topics全新排版,依主題瀏覽;更提供互動計算功能Regularly Updated每月定期線上更新,依據最新證據提供最新發展P art02開始安裝START TO INSTALL依行動裝置類型下載適合之APPiOS 9.0+Android 6.0+Win10Kindle適用於iPhone, iPad, 和iPod touch.適用於Xbox One ,Win 10 版本10586.0 +熱病Sanford Guide App安裝說明簡介:熱病提供各系統器官感染疾病的常見病原體(例如:細菌、真菌、寄生蟲和病毒等)、傳播途徑、診斷要點、首選和備選治療方案、藥物不良反應和應用注意事項,以及預防用藥等,並輔以相關文獻來體現實證醫學的權威性。
SSI III型泵手册
Laballiance III型泵使用手册第一章 简介本手册为用户操作、安装及进行简单维修提供所需之信息和内容。
1.1 LABALLIANCE III PUMP简介LABALLIANCE III PUMP高效液相色谱泵特别适用于常规分析及科研探索性应用。
除此而外,该泵还可用于普通实验室及工业上作为定量泵使用。
标准10ml 泵头的LABALLIANCE III PUMP流速能以 0.01ml/min 的增量设定范围为 0.01~9.99ml/min ,精度 0.1%。
采用40ml泵头,LABALLIANCE III PUMP 设定范围可达 0.1~39.9ml/min 。
任何泵头均可以选用316不锈钢或生物兼容体(Bioclean)。
为了获取无脉冲流速,LABALLIANCE III PUMP采用先进的快速充盈式活塞,可编程步进电机及脉冲均速器等设计。
1.2 泵特征z LABALLIANCE III PUMP泵能非常容易转变以满足微量分析及半制备应用。
z采用隔膜式脉冲均速器,降低90%的脉冲。
z液路外压力传感器设计,既避免了流动相对压力传感器的损伤,又不致增大液路死体积。
z高低压限设置,可以自动关闭泵,防止系统压力过高或泄漏。
z内置旁通阀设计。
z自清洗泵头。
z电子管显示跟踪流速及压力变化。
1.3 液路系统所有各型泵液路接触面均包括红/蓝宝石。
其中不锈钢类型还有316型不锈钢及氟碳高聚物;生物兼容型包含惰性聚合物。
1.4 自清洗泵头自清洗泵头的设计提供了高压密封及柱塞杆的连续清洗,且无需手动注射也无需重力牵引。
人所共知,柱塞杆注射完流动相后,柱塞杆表面均会形成一层液膜,假如此时使用的流动相含有盐份,该液膜流动相溶剂蒸发,盐即结晶析出而附着于柱塞杆表面。
这些结晶极易损伤柱塞密封,从而造成泄漏。
自清洗泵头则采用二级密封和单向阀,建立了高压密封后的连续清洗液流,柱塞杆离开流动相即进入此清洗液流,完全清洗掉其表面液膜,防止盐类结晶析出,从而保证了高压密封的寿命。
总三碘甲状腺原氨酸(T3)测定试剂盒(磁微粒化学发光免疫分析法)产品技术要求中航赛维
总三碘甲状腺原氨酸(T3)测定试剂盒(磁微粒化学发光免疫分析法)适用范围:该产品用于体外定量测定人血清中的总三碘甲状腺原氨酸(T3)含量1.1 产品规格100测试/盒。
1.2 划分说明1.2.1 T3试剂1号(T3-R1):5mL/瓶×1瓶,含有T3单克隆抗体(0.05μg/mL)、牛血清白蛋白(0.5%)的Tris缓冲液(0.1mol/L,pH=8.0)。
1.2.2 T3试剂2号(T3-R2): 5mL/瓶×1瓶,含有ALP标记的T3抗原(0.1μg/mL)、牛血清白蛋白(0.5%)的Tris缓冲液(0.1mol/L,pH=8.0)。
1.2.3 T3磁分离试剂(T3-M):5mL/瓶×1瓶,含有标记羊抗鼠IgG抗体的磁性微粒(0.5mg/mL)、牛血清白蛋白(0.5%)的Tris缓冲液(0.1mol/L,pH=8.0)。
1.2.4 T3校准品(T3-STD)(选配):6个水平的液体校准品, 0.5mL/瓶×6瓶,含一定浓度T3抗原和去激素人血清(pH=7.4)。
目标浓度分别为0、0.5、1、2、4和8ng /mL。
1.2.5 T3质控品(T3-QC)(选配):2个水平的液体质控品,1mL/瓶×2瓶,含一定量T3抗原和去激素人血清(pH=7.4)。
靶值范围分别为:(1±0.2)ng/mL 和(4±0.8)ng/mL。
校准品和质控品浓度具有批特异性,具体浓度详见每批的校准品和质控品条形码。
本试剂盒校准品可溯源至国家标准物质(编号150550)注:不同批号试剂组分不可以互换使用。
2.1 外观2.1.1 试剂盒各组分应齐全、完整、液体无渗漏;2.1.2 磁分离试剂摇匀后为均匀悬浊液,无明显凝集;2.1.3 液体组分应澄清,无沉淀或絮状物;2.1.4 包装标签应清晰,易识别;2.1.5 各组分装量不得低于标示体积。
2.2 溯源性应根据GB/T21415-2008及有关规定提供校准品的来源、溯源的赋值方法和相应指标、以及不确定度等内容。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
3. 在未安装内置保险丝, 断路器或其他类似的保护装置仪器中, 备用电路板须有保险装置。 4. 在开机前,确保仪器调制的额定电压要符合 AC 供电网络的额定电压。
若设定不同电压, 电源保险丝则需相应改变。
1145ቤተ መጻሕፍቲ ባይዱ5980.19
2
C-1
R&S FSH3
简介
5. 若仪器没有切断 AC 电源的开关,电线插头则可作为断电装置。 所以在这种情况下,确保电线插头要便于取到( 电线长度约为 2 米). 功能和电子开关不适于 AC 电源的切断。 若没有电源开关的仪器与系统设备连接,电源开关则应在系统设备上 。
目录
1 安全说明................................................................................................................................ 2 2 质量认证................................................................................................................................ 3 3 技术支持中心地址................................................................................................................ 3 4 正面图.................................................................................................................................... 5 5 开始操作................................................................................................................................ 5 6 拆除包装................................................................................................................................ 5 7 设置装置................................................................................................................................ 6 8 打开频谱仪............................................................................................................................ 8 9 频谱仪接口............................................................................................................................ 9 10 显示器设置........................................................................................................................ 10 11 语言选择............................................................................................................................ 11 12 设置日期和时间................................................................................................................ 12 13 电池充电............................................................................................................................ 14 14 PIN 码输入 ........................................................................................................................ 18 15 连接打印机........................................................................................................................ 20 16 启动选件............................................................................................................................ 22 17 开始操作............................................................................................................................ 24 18 CW 信号的测量 ................................................................................................................ 24 19 电平测量............................................................................................................................ 24 20 设置参考电平.................................................................................................................... 25 21 频率测量............................................................................................................................ 26 22 谐波测量............................................................................................................................ 27 23 功率探头的使用................................................................................................................ 28 24 双端口传输测量................................................................................................................ 30 25 回波损耗(反射系数)测量 ................................................................................................. 32 26 电缆不良点测量................................................................................................................ 34 27 检索设置和测试结果........................................................................................................ 42 28 储存测量结果.................................................................................................................... 42 29 调用测量结果.................................................................................................................... 43 30 打印测量结果.................................................................................................................... 36
7. 确保与信息系统设备的联接符合 IEC950 / EN60950.
8. NiMH 电池不可放置于高温下或火中。 电池 应远离于儿童放置。 若电池误换, 则会引起爆炸。替换电池应为 R&S 系列 (参见备用零件列表). NiMH 电池 是属于 环保 类型的电池 并 能够 回收 再利用 。 故 应 将 投入 相应的 回收箱内 。要避免 造成短路 。